WorldWideScience

Sample records for single precision cowell

  1. Time transformations and Cowell's method. [for numerical integration of satellite motion equations

    Science.gov (United States)

    Velez, C. E.; Hilinski, S.

    1978-01-01

    The precise numerical integration of Cowell's equations of satellite motion is frequently performed with an independent variable s defined by an equation of the form dt = cr to the n-th power ds, where t represents time, r the radial distance from the center of attraction, c is a constant, and n is a parameter. This has been primarily motivated by the 'uniformizing' effects of such a transformation resulting in desirable 'analytic' stepsize control for elliptical orbits. This report discusses the 'proper' choice of the parameter n defining the independent variable s for various types of orbits and perturbation models, and develops a criterion for its selection.

  2. Storner-Cowell: straight, summed and split; An overview

    NARCIS (Netherlands)

    Frankena, J.F.

    1995-01-01

    In this paper we consider the relationship between some (forms of) specific numerical methods for (second-order) initial value problems. In particular, the Störmer-Cowell method in second-sum form is shown to be the Gauss-Jackson method (and analogously, for the sake of completeness, we relate

  3. Single-Atom Transistor as a Precise Magnetic Field Sensor

    Science.gov (United States)

    Jachymski, Krzysztof; Wasak, Tomasz; Idziaszek, Zbigniew; Julienne, Paul S.; Negretti, Antonio; Calarco, Tommaso

    2018-01-01

    Feshbach resonances, which allow for tuning the interactions of ultracold atoms with an external magnetic field, have been widely used to control the properties of quantum gases. We propose a scheme for using scattering resonances as a probe for external fields, showing that by carefully tuning the parameters it is possible to reach a 10-5 G (or nT) level of precision with a single pair of atoms. We show that, for our collisional setup, it is possible to saturate the quantum precision bound with a simple measurement protocol.

  4. Single seed precise sowing of maize using computer simulation.

    Science.gov (United States)

    Zhao, Longgang; Han, Zhongzhi; Yang, Jinzhong; Qi, Hua

    2018-01-01

    In order to test the feasibility of computer simulation in field maize planting, the selection of the method of single seed precise sowing in maize is studied based on the quadratic function model Y = A×(D-Dm)2+Ym, which depicts the relationship between maize yield and planting density. And the advantages and disadvantages of the two planting methods under the condition of single seed sowing are also compared: Method 1 is optimum density planting, while Method 2 is the ideal seedling emergence number planting. It is found that the yield reduction rate and yield fluctuation of Method 2 are all lower than those of Method 1. The yield of Method 2 increased by at least 0.043 t/hm2, and showed more advantages over Method 1 with higher yield level. Further study made on the influence of seedling emergence rate on the yield of maize finds that the yields of the two methods are both highly positively correlated with the seedling emergence rate and the standard deviations of their yields are both highly negatively correlated with the seedling emergence rate. For the study of the break-up problem of sparse caused by the method of single seed precise sowing, the definition of seedling missing spots is put forward. The study found that the relationship between number of hundred-dot spot and field seedling emergence rate is as the parabola function y = -189.32x2 + 309.55x - 118.95 and the relationship between number of spot missing seedling and field seedling emergence rate is as the negative exponent function y = 395.69e-6.144x. The results may help to guide the maize seeds production and single seed precise sowing to some extent.

  5. Shuttle orbit IMU alignment. Single-precision computation error

    Science.gov (United States)

    Mcclain, C. R.

    1980-01-01

    The source of computational error in the inertial measurement unit (IMU) onorbit alignment software was investigated. Simulation runs were made on the IBM 360/70 computer with the IMU orbit alignment software coded in hal/s. The results indicate that for small IMU misalignment angles (less than 600 arc seconds), single precision computations in combination with the arc cosine method of eigen rotation angle extraction introduces an additional misalignment error of up to 230 arc seconds per axis. Use of the arc sine method, however, produced negligible misalignment error. As a result of this study, the arc sine method was recommended for use in the IMU onorbit alignment software.

  6. Precision control of single-molecule electrical junctions.

    Science.gov (United States)

    Haiss, Wolfgang; Wang, Changsheng; Grace, Iain; Batsanov, Andrei S; Schiffrin, David J; Higgins, Simon J; Bryce, Martin R; Lambert, Colin J; Nichols, Richard J

    2006-12-01

    There is much discussion of molecules as components for future electronic devices. However, the contacts, the local environment and the temperature can all affect their electrical properties. This sensitivity, particularly at the single-molecule level, may limit the use of molecules as active electrical components, and therefore it is important to design and evaluate molecular junctions with a robust and stable electrical response over a wide range of junction configurations and temperatures. Here we report an approach to monitor the electrical properties of single-molecule junctions, which involves precise control of the contact spacing and tilt angle of the molecule. Comparison with ab initio transport calculations shows that the tilt-angle dependence of the electrical conductance is a sensitive spectroscopic probe, providing information about the position of the Fermi energy. It is also shown that the electrical properties of flexible molecules are dependent on temperature, whereas those of molecules designed for their rigidity are not.

  7. Single-molecule imaging towards precise detection of individual photophysics

    International Nuclear Information System (INIS)

    Tani, Toshiro; Oda, Masaru; Mashimo, Kei; Tachibana, Fumi; Horiuchi, Hiromi

    2006-01-01

    We present our recent study of single fluorescent molecules with specific structure, i.e. tetramethylrhodamine derivative linked with a propyl chain onto silica glass surface. For fluorescent reagent in its synthesis, we used a mixture of two kinds of isomers, which provides a sample with single molecules photophysically different each other even if chemically the same. The isomeric structural difference so introduced in the molecules will provide rather small but probably distinctive photophysical difference, for example, in non-radiative relaxation rates, which we try to detect out with our improved single-molecule microscope imaging technique. To make clear the detectability of such weak inter- or intra-molecular interactions microscopically is significant for versatile applications of single-molecule detections in life science. Our present observation at room temperatures shows so far that such decoupled contributions can be discriminated in the histograms of the intensities of the observed fluorescent spots as broader but separated multi-component structures in the distribution under specific experimental configurations. We will discuss some of the prerequisite for such detections; suitable spatio-temporal resolutions with sufficient S/N ratio, algorithms for data analysis, etc. but also precise sample operations are inevitable

  8. Atomically precise graphene nanoribbon heterojunctions from a single molecular precursor

    Science.gov (United States)

    Nguyen, Giang D.; Tsai, Hsin-Zon; Omrani, Arash A.; Marangoni, Tomas; Wu, Meng; Rizzo, Daniel J.; Rodgers, Griffin F.; Cloke, Ryan R.; Durr, Rebecca A.; Sakai, Yuki; Liou, Franklin; Aikawa, Andrew S.; Chelikowsky, James R.; Louie, Steven G.; Fischer, Felix R.; Crommie, Michael F.

    2017-11-01

    The rational bottom-up synthesis of atomically defined graphene nanoribbon (GNR) heterojunctions represents an enabling technology for the design of nanoscale electronic devices. Synthetic strategies used thus far have relied on the random copolymerization of two electronically distinct molecular precursors to yield GNR heterojunctions. Here we report the fabrication and electronic characterization of atomically precise GNR heterojunctions prepared through late-stage functionalization of chevron GNRs obtained from a single precursor. Post-growth excitation of fully cyclized GNRs induces cleavage of sacrificial carbonyl groups, resulting in atomically well-defined heterojunctions within a single GNR. The GNR heterojunction structure was characterized using bond-resolved scanning tunnelling microscopy, which enables chemical bond imaging at T = 4.5 K. Scanning tunnelling spectroscopy reveals that band alignment across the heterojunction interface yields a type II heterojunction, in agreement with first-principles calculations. GNR heterojunction band realignment proceeds over a distance less than 1 nm, leading to extremely large effective fields.

  9. Precision of single-engage micro Hall effect measurements

    DEFF Research Database (Denmark)

    Henrichsen, Henrik Hartmann; Hansen, Ole; Kjær, Daniel

    2014-01-01

    Recently a novel microscale Hall effect measurement technique has been developed to extract sheet resistance (RS), Hall sheet carrier density (NHS) and Hall mobility (μH) from collinear micro 4-point probe measurements in the vicinity of an insulating boundary [1]. The technique measures in less......]. In this study we calculate the measurement error on RS, NHS and μH resulting from electrode position errors, probe placement, sample size and Hall signal magnitude. We show the relationship between measurement precision and electrode pitch, which is important when down-scaling the micro 4-point probe to fit...

  10. Precise analysis of the metal package photomultiplier single photoelectron spectra

    International Nuclear Information System (INIS)

    Chirikov-Zorin, I.E.; Fedorko, I.; Sykora, I.; Tokar, S.; Menzione, A.

    2000-01-01

    A deconvolution method based on a sophisticated photomultiplier response function was used to analyse the compact metal package photomultiplier spectra taken in single photoelectron mode. The spectra taken by Hamamtsu R5600 and R5900 photomultipliers have been analysed. The detailed analysis shows that the method appropriately describes the process of charge multiplication in these photomultipliers in a wide range of working regimes and the deconvoluted parameters are established with about 1% accuracy. The method can be used for a detailed analysis of photomultiplier noise and for calibration purposes

  11. Improving Precision of Proximity Ligation Assay by Amplified Single Molecule Detection

    OpenAIRE

    Ke, Rongqin; Nong, Rachel Yuan; Fredriksson, Simon; Landegren, Ulf; Nilsson, Mats

    2013-01-01

    Proximity ligation assay (PLA) has been proven to be a robust protein detection method. The technique is characterized by high sensitivity and specificity, but the assay precision is probably limited by the PCR readout. To investigate this potential limitation and to improve precision, we developed a digital proximity ligation assay for protein measurement in fluids based on amplified single molecule detection. The assay showed significant improvements in precision, and thereby also detection...

  12. Real-time multi-GNSS single-frequency precise point positioning

    NARCIS (Netherlands)

    de Bakker, P.F.; Tiberius, C.C.J.M.

    2017-01-01

    Precise Point Positioning (PPP) is a popular Global Positioning System (GPS) processing strategy, thanks to its high precision without requiring additional GPS infrastructure. Single-Frequency PPP (SF-PPP) takes this one step further by no longer relying on expensive dual-frequency GPS receivers,

  13. Single Crystal Piezomotor for Large Stroke, High Precision and Cryogenic Actuations, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes a novel single crystal piezomotor for large stroke, high precision, and cryogenic actuations with capability of position set-hold with...

  14. Towards a Precise Measurement of Atomic Parity Violation in a Single Ra+ Ion

    NARCIS (Netherlands)

    Jungmann, K.; Giri, G. S.; Versolato, O. O.; Steadman, SG; Stephans, GSF; Taylor, FE

    2012-01-01

    In the singly charged Ra+ ion the contributions of the weak interactions to the atomic level energies are some 50 times larger than in the Cs atom. We report the results of laser spectroscopy experiments on Ra-209-214(+) isotopes in preparation of a precision atomic parity violation experiment.

  15. Single Cell Transfection through Precise Microinjection with Quantitatively Controlled Injection Volumes

    Science.gov (United States)

    Chow, Yu Ting; Chen, Shuxun; Wang, Ran; Liu, Chichi; Kong, Chi-Wing; Li, Ronald A.; Cheng, Shuk Han; Sun, Dong

    2016-04-01

    Cell transfection is a technique wherein foreign genetic molecules are delivered into cells. To elucidate distinct responses during cell genetic modification, methods to achieve transfection at the single-cell level are of great value. Herein, we developed an automated micropipette-based quantitative microinjection technology that can deliver precise amounts of materials into cells. The developed microinjection system achieved precise single-cell microinjection by pre-patterning cells in an array and controlling the amount of substance delivered based on injection pressure and time. The precision of the proposed injection technique was examined by comparing the fluorescence intensities of fluorescent dye droplets with a standard concentration and water droplets with a known injection amount of the dye in oil. Injection of synthetic modified mRNA (modRNA) encoding green fluorescence proteins or a cocktail of plasmids encoding green and red fluorescence proteins into human foreskin fibroblast cells demonstrated that the resulting green fluorescence intensity or green/red fluorescence intensity ratio were well correlated with the amount of genetic material injected into the cells. Single-cell transfection via the developed microinjection technique will be of particular use in cases where cell transfection is challenging and genetically modified of selected cells are desired.

  16. Real-Time Single Frequency Precise Point Positioning Using SBAS Corrections

    Directory of Open Access Journals (Sweden)

    Liang Li

    2016-08-01

    Full Text Available Real-time single frequency precise point positioning (PPP is a promising technique for high-precision navigation with sub-meter or even centimeter-level accuracy because of its convenience and low cost. The navigation performance of single frequency PPP heavily depends on the real-time availability and quality of correction products for satellite orbits and satellite clocks. Satellite-based augmentation system (SBAS provides the correction products in real-time, but they are intended to be used for wide area differential positioning at 1 meter level precision. By imposing the constraints for ionosphere error, we have developed a real-time single frequency PPP method by sufficiently utilizing SBAS correction products. The proposed PPP method are tested with static and kinematic data, respectively. The static experimental results show that the position accuracy of the proposed PPP method can reach decimeter level, and achieve an improvement of at least 30% when compared with the traditional SBAS method. The positioning convergence of the proposed PPP method can be achieved in 636 epochs at most in static mode. In the kinematic experiment, the position accuracy of the proposed PPP method can be improved by at least 20 cm relative to the SBAS method. Furthermore, it has revealed that the proposed PPP method can achieve decimeter level convergence within 500 s in the kinematic mode.

  17. Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera

    International Nuclear Information System (INIS)

    Uesaka, M.; Ueda, T.; Kozawa, T.; Kobayashi, T.

    1998-01-01

    Precise measurement of a subpicosecond electron single bunch by the femtosecond streak camera is presented. The subpicosecond electron single bunch of energy 35 MeV was generated by the achromatic magnetic pulse compressor at the S-band linear accelerator of nuclear engineering research laboratory (NERL), University of Tokyo. The electric charge per bunch and beam size are 0.5 nC and the horizontal and vertical beam sizes are 3.3 and 5.5 mm (full width at half maximum; FWHM), respectively. Pulse shape of the electron single bunch is measured via Cherenkov radiation emitted in air by the femtosecond streak camera. Optical parameters of the optical measurement system were optimized based on much experiment and numerical analysis in order to achieve a subpicosecond time resolution. By using the optimized optical measurement system, the subpicosecond pulse shape, its variation for the differents rf phases in the accelerating tube, the jitter of the total system and the correlation between measured streak images and calculated longitudinal phase space distributions were precisely evaluated. This measurement system is going to be utilized in several subpicosecond analyses for radiation physics and chemistry. (orig.)

  18. Changes in ion channel geometry resolved to sub-angstroem precision via single molecule mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Joseph W F; Kasianowicz, John J; Reiner, Joseph E [Semiconductor Electronics Division, Electronics and Electrical Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2010-11-17

    The ion channel formed by Staphylococcus aureus alpha-hemolysin switches between multiple open conducting states. We describe a method for precisely estimating the changes in the ion channel geometry that correspond to these different states. Experimentally, we observed that the permeability of a single channel to differently sized poly(ethylene glycol) molecules depends on the magnitude of the open state conductance. A simple theory is proposed for determining changes in channel length of 4.2% and in cross-sectional area of - 0.4%.

  19. Precision ESR Measurements of Transverse Anisotropy in the Single-molecule Magnet Ni4

    Science.gov (United States)

    Friedman, Jonathan; Collett, Charles; Allao Cassaro, Rafael

    We present a method to precisely determine the transverse anisotropy in a single-molecule magnet (SMM) through electron-spin resonance measurements of a tunnel splitting that arises from the anisotropy via first-order perturbation theory. We demonstrate the technique using the SMM Ni4 diluted via co-crystallization in a diamagnetic isostructural analogue. At 5% dilution, we find markedly narrower resonance peaks than are observed in undiluted samples. Ni4 has a zero-field tunnel splitting of 4 GHz, and we measure that transition at several nearby frequencies using custom loop-gap resonators, allowing a precise determination of the tunnel splitting. Because the transition under investigation arises due to a first-order perturbation from the transverse anisotropy, and lies at zero field, we can relate the splitting to the transverse anisotropy independent of any other Hamiltonian parameters. This method can be applied to other SMMs with zero-field tunnel splittings arising from first-order transverse anisotropy perturbations. NSF Grant No. DMR-1310135.

  20. Development of a High-Precision Touch-Trigger Probe Using a Single Sensor

    Directory of Open Access Journals (Sweden)

    Rui-Jun Li

    2016-03-01

    Full Text Available To measure various components with nano-scale precision, a new high-precision touch-trigger probe using a single low-cost sensor for a micro-coordinate measuring machine (CMM is presented in this paper. The sensor is composed of a laser diode, a plane mirror, a focusing lens, and a quadrant photo detector (QPD. The laser beam from the laser diode with an incident angle is reflected by the plane mirror and then projected onto the quadrant photo detector (QPD via the focusing lens. The plane mirror is adhered to the upper surface of the floating plate supported by an elastic mechanism, which can transfer the displacement of the stylus’s ball tip in 3D to the plane mirror’s vertical and tilt movement. Both motions of the plane mirror can be detected by respective QPDs. The probe mechanism was analyzed, and its structural parameters that conform to the principle of uniform sensitivity and uniform stiffness were obtained. The simulation result showed that the stiffness was equal in 3D and less than 1 mN/µm. Some experiments were performed to investigate the probe’s characteristics. It was found that the probe could detect the trigger point with uniform sensitivity, a resolution of less than 5 nm, and a repeatability of less than 4 nm. It can be used as a touch-trigger probe on a micro/nano-CMM.

  1. Surface finish in ultra-precision diamond turning of single-crystal silicon

    Science.gov (United States)

    Ayomoh, M.; Abou-El-Hossein, K.

    2015-10-01

    Silicon is an optical material widely used in the production of infrared optics. However, silicon as a brittle material exhibits some difficulties when ultra-precision machined by mono-crystalline single point diamond. Finish turning of silicon with mono- crystalline diamond inserts results in accelerated tool wear rates if the right combination of the machining parameters is not properly selected. In this study, we conducted a series of machining tests on an ultra-high precision machine tool using finish turning conditions when using mono-crystalline diamond inserts with negative rake angle and relatively big nose radius. The study yields some recommendations on the best combination of machining parameters that will result in maximum material removal rates with smallest possible surface finish. In this work, standard non-controlled waviness diamond inserts having nose radius of about 1.5 mm, rake angle of negative 25°, and clearance angle of 5° were used to produce flat surfaces on silicon disk. From the results, it has been established that feed rate has the most influential effect followed by the depth of cut and cutting speed.

  2. A precise goniometer/tensiometer using a low cost single-board computer

    Science.gov (United States)

    Favier, Benoit; Chamakos, Nikolaos T.; Papathanasiou, Athanasios G.

    2017-12-01

    Measuring the surface tension and the Young contact angle of a droplet is extremely important for many industrial applications. Here, considering the booming interest for small and cheap but precise experimental instruments, we have constructed a low-cost contact angle goniometer/tensiometer, based on a single-board computer (Raspberry Pi). The device runs an axisymmetric drop shape analysis (ADSA) algorithm written in Python. The code, here named DropToolKit, was developed in-house. We initially present the mathematical framework of our algorithm and then we validate our software tool against other well-established ADSA packages, including the commercial ramé-hart DROPimage Advanced as well as the DropAnalysis plugin in ImageJ. After successfully testing for various combinations of liquids and solid surfaces, we concluded that our prototype device would be highly beneficial for industrial applications as well as for scientific research in wetting phenomena compared to the commercial solutions.

  3. Label-free screening of single biomolecules through resistive pulse sensing technology for precision medicine applications

    Science.gov (United States)

    Harrer, S.; Kim, S. C.; Schieber, C.; Kannam, S.; Gunn, N.; Moore, S.; Scott, D.; Bathgate, R.; Skafidas, S.; Wagner, J. M.

    2015-05-01

    Employing integrated nano- and microfluidic circuits for detecting and characterizing biological compounds through resistive pulse sensing technology is a vibrant area of research at the interface of biotechnology and nanotechnology. Resistive pulse sensing platforms can be customized to study virtually any particle of choice which can be threaded through a fluidic channel and enable label-free single-particle interrogation with the primary read-out signal being an electric current fingerprint. The ability to perform label-free molecular screening with single-molecule and even single binding site resolution makes resistive pulse sensing technology a powerful tool for analyzing the smallest units of biological systems and how they interact with each other on a molecular level. This task is at the core of experimental systems biology and in particular ‘omics research which in combination with next-generation DNA-sequencing and next-generation drug discovery and design forms the foundation of a novel disruptive medical paradigm commonly referred to as personalized medicine or precision medicine. DNA-sequencing has approached the 1000-Dollar-Genome milestone allowing for decoding a complete human genome with unmatched speed and at low cost. Increased sequencing efficiency yields massive amounts of genomic data. Analyzing this data in combination with medical and biometric health data eventually enables understanding the pathways from individual genes to physiological functions. Access to this information triggers fundamental questions for doctors and patients alike: what are the chances of an outbreak for a specific disease? Can individual risks be managed and if so how? Which drugs are available and how should they be applied? Could a new drug be tailored to an individual’s genetic predisposition fast and in an affordable way? In order to provide answers and real-life value to patients, the rapid evolvement of novel computing approaches for analyzing big data in

  4. Precision requirements for single-layer feed-forward neural networks

    NARCIS (Netherlands)

    Annema, Anne J.; Hoen, K.; Hoen, Klaas; Wallinga, Hans

    1994-01-01

    This paper presents a mathematical analysis of the effect of limited precision analog hardware for weight adaptation to be used in on-chip learning feedforward neural networks. Easy-to-read equations and simple worst-case estimations for the maximum tolerable imprecision are presented. As an

  5. Site-selective substitutional doping with atomic precision on stepped Al (111) surface by single-atom manipulation.

    Science.gov (United States)

    Chen, Chang; Zhang, Jinhu; Dong, Guofeng; Shao, Hezhu; Ning, Bo-Yuan; Zhao, Li; Ning, Xi-Jing; Zhuang, Jun

    2014-01-01

    In fabrication of nano- and quantum devices, it is sometimes critical to position individual dopants at certain sites precisely to obtain the specific or enhanced functionalities. With first-principles simulations, we propose a method for substitutional doping of individual atom at a certain position on a stepped metal surface by single-atom manipulation. A selected atom at the step of Al (111) surface could be extracted vertically with an Al trimer-apex tip, and then the dopant atom will be positioned to this site. The details of the entire process including potential energy curves are given, which suggests the reliability of the proposed single-atom doping method.

  6. Advanced single tooth torquing plier with high precision: A clinical innovation

    Directory of Open Access Journals (Sweden)

    Jitendra Raghuwanshi

    2017-01-01

    Full Text Available Torque is the force which gives the operator control over the movements of roots of teeth in bilateral direction. There are various pliers available to apply torque in individual tooth, but none of the pliers are capable of measuring accurately the degrees of torque incorporated, so we have attempted to make a modified torquing plier to incorporate and measure the degrees of incorporated torque precisely.

  7. Quantum fluctuations and coherence in high-precision single-electron capture.

    Science.gov (United States)

    Kashcheyevs, Vyacheslavs; Timoshenko, Janis

    2012-11-21

    The phase of a single quantum state is undefined unless the history of its creation provides a reference point. Thus, quantum interference may seem hardly relevant for the design of deterministic single-electron sources which strive to isolate individual charge carriers quickly and completely. We provide a counterexample by analyzing the nonadiabatic separation of a localized quantum state from a Fermi sea due to a closing tunnel barrier. We identify the relevant energy scales and suggest ways to separate the contributions of quantum nonadiabatic excitation and back tunneling to the rare noncapture events. In the optimal regime of balanced decay and nonadiabaticity, our simple electron trap turns into a single-lead Landau-Zener back tunneling interferometer, revealing the dynamical phase accumulated between the particle capture and leakage. The predicted "quantum beats in back tunneling" may turn the error of a single-electron source into a valuable signal revealing essentially nonadiabatic energy scales of a dynamic quantum dot.

  8. Precise Patterning of Organic Single Crystals via Capillary-Assisted Alternating-Electric Field.

    Science.gov (United States)

    Zhang, Yedong; Jie, Jiansheng; Sun, Yuning; Jeon, Seok-Gy; Zhang, Xiujuan; Dai, Gaole; Lee, Cheol Jin; Zhang, Xiaohong

    2017-07-01

    Owing to the extraordinary properties, organic micro/nanocrystals are important building blocks for future low-cost and high-performance organic electronic devices. However, integrated device application of the organic micro/nanocrystals is hampered by the difficulty in high-throughput, high-precision patterning of the micro/nanocrystals. In this study, the authors demonstrate, for the first time, a facile capillary-assisted alternating-electric field method for the large-scale assembling and patterning of both 0D and 1D organic crystals. These crystals can be precisely patterned at the photolithography defined holes/channels at the substrate with the yield up to 95% in 1 mm 2 . The mechanism of assembly kinetics is systematically studied by the electric field distribution simulation and experimental investigations. By using the strategy, various organic micro/nanocrystal patterns are obtained by simply altering the geometries of the photoresist patterns on substrates. Moreover, ultraviolet photodetectors based on the patterned Alq3 micro/nanocrystals exhibit visible-blind photoresponse with high sensitivity as well as excellent stability and reproducibility. This work paves the way toward high-integration, high-performance organic electronic, and optoelectronic devices from the organic micro/nanocrystals. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Single Cobalt Atoms with Precise N-Coordination as Superior Oxygen Reduction Reaction Catalysts.

    Science.gov (United States)

    Yin, Peiqun; Yao, Tao; Wu, Yuen; Zheng, Lirong; Lin, Yue; Liu, Wei; Ju, Huanxin; Zhu, Junfa; Hong, Xun; Deng, Zhaoxiang; Zhou, Gang; Wei, Shiqiang; Li, Yadong

    2016-08-26

    A new strategy for achieving stable Co single atoms (SAs) on nitrogen-doped porous carbon with high metal loading over 4 wt % is reported. The strategy is based on a pyrolysis process of predesigned bimetallic Zn/Co metal-organic frameworks, during which Co can be reduced by carbonization of the organic linker and Zn is selectively evaporated away at high temperatures above 800 °C. The spherical aberration correction electron microscopy and extended X-ray absorption fine structure measurements both confirm the atomic dispersion of Co atoms stabilized by as-generated N-doped porous carbon. Surprisingly, the obtained Co-Nx single sites exhibit superior ORR performance with a half-wave potential (0.881 V) that is more positive than commercial Pt/C (0.811 V) and most reported non-precious metal catalysts. Durability tests revealed that the Co single atoms exhibit outstanding chemical stability during electrocatalysis and thermal stability that resists sintering at 900 °C. Our findings open up a new routine for general and practical synthesis of a variety of materials bearing single atoms, which could facilitate new discoveries at the atomic scale in condensed materials. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Changes in ion channel geometry resolved to sub-ångström precision via single molecule mass spectrometry

    Science.gov (United States)

    Robertson, Joseph W. F.; Kasianowicz, John J.; Reiner, Joseph E.

    2010-11-01

    The ion channel formed by Staphylococcus aureus alpha-hemolysin switches between multiple open conducting states. We describe a method for precisely estimating the changes in the ion channel geometry that correspond to these different states. Experimentally, we observed that the permeability of a single channel to differently sized poly(ethylene glycol) molecules depends on the magnitude of the open state conductance. A simple theory is proposed for determining changes in channel length of 4.2% and in cross-sectional area of - 0.4%.

  11. A Dewetting-Induced Assembly Strategy for Precisely Patterning Organic Single Crystals in OFETs.

    Science.gov (United States)

    Kan, Xiaonan; Xiao, Chengyi; Li, Xinmeng; Su, Bin; Wu, Yuchen; Jiang, Wei; Wang, Zhaohui; Jiang, Lei

    2016-07-27

    Simple methods for patterning single crystals are critical to fully realize their applications in electronics. However, traditional vapor and solution methods are deficient in terms of crystals with random spatial and quality distributions. In this work, we report a dewetting-induced assembly strategy for obtaining large-scale and highly oriented organic crystal arrays. We also demonstrate that organic field-effect transistors (OFETs) fabricated from patterned n-alkyl-substituted tetrachloroperylene diimide (R-4ClPDI) single crystals can reach a maximum mobility of 0.65 cm(2) V(-1) s(-1) for C8-4ClPDI in ambient conditions. This technique constitutes a facile method for fabricating OFETs with high performances for large-scale electronics applications.

  12. Regio-Regular Oligo and Poly(3-hexyl thiophene): Precise Structural Markers from the Vibrational Spectra of Oligomer Single Crystals.

    KAUST Repository

    Brambilla, Luigi

    2014-10-14

    © 2014 American Chemical Society. In this work, we report a comparative analysis of the infrared and Raman spectra of octa(3-hexylthiophene) (3HT)8, trideca(3-hexylthiophene) (3HT)13, and poly(3-hexylthiophene) P3HT recorded in various phases, namely, amorphous, semicrystalline, polycrystalline and single crystal. We have based our analysis on the spectra of the (3HT)8 single crystal (whose structure has been determined by selected area electron diffraction) taken as reference and on the results of DFT calculations and molecular vibrational dynamics. New and precise spectroscopic markers of the molecular structures show the existence of three phases, namely: hairy (phase 1), ordered (phase 2), and disordered/amorphous (phase 3). Conceptually, the identified markers can be used for the molecular structure analysis of other similar systems.

  13. Ambiguity resolution in precise point positioning with hourly data for global single receiver

    Science.gov (United States)

    Zhang, Xiaohong; Li, Pan; Guo, Fei

    2013-01-01

    Integer ambiguity resolution (IAR) can improve precise point positioning (PPP) performance significantly. IAR for PPP became a highlight topic in global positioning system (GPS) community in recent years. More and more researchers focus on this issue. Progress has been made in the latest years. In this paper, we aim at investigating and demonstrating the performance of a global zero-differenced (ZD) PPP IAR service for GPS users by providing routine ZD uncalibrated fractional offsets (UFOs) for wide-lane and narrow-lane. Data sets from all IGS stations collected on DOY 1, 100, 200 and 300 of 2010 are used to validate and demonstrate this global service. Static experiment results show that an accuracy better than 1 cm in horizontal and 1-2 cm in vertical could be achieved in ambiguity-fixed PPP solution with only hourly data. Compared with PPP float solution, an average improvement reaches 58.2% in east, 28.3% in north and 23.8% in vertical for all tested stations. Results of kinematic experiments show that the RMS of kinematic PPP solutions can be improved from 21.6, 16.6 and 37.7 mm to 12.2, 13.3 and 34.3 mm for the fixed solutions in the east, north and vertical components, respectively. Both static and kinematic experiments show that wide-lane and narrow-lane UFO products of all satellites can be generated and provided in a routine way accompanying satellite orbit and clock products for the PPP user anywhere around the world, to obtain accurate and reliable ambiguity-fixed PPP solutions.

  14. High-Precision Displacement Sensing of Monolithic Piezoelectric Disk Resonators Using a Single-Electron Transistor

    Science.gov (United States)

    Li, J.; Santos, J. T.; Sillanpää, M. A.

    2018-02-01

    A single-electron transistor (SET) can be used as an extremely sensitive charge detector. Mechanical displacements can be converted into charge, and hence, SETs can become sensitive detectors of mechanical oscillations. For studying small-energy oscillations, an important approach to realize the mechanical resonators is to use piezoelectric materials. Besides coupling to traditional electric circuitry, the strain-generated piezoelectric charge allows for measuring ultrasmall oscillations via SET detection. Here, we explore the usage of SETs to detect the shear-mode oscillations of a 6-mm-diameter quartz disk resonator with a resonance frequency around 9 MHz. We measure the mechanical oscillations using either a conventional DC SET, or use the SET as a homodyne or heterodyne mixer, or finally, as a radio-frequency single-electron transistor (RF-SET). The RF-SET readout is shown to be the most sensitive method, allowing us to measure mechanical displacement amplitudes below 10^{-13} m. We conclude that a detection based on a SET offers a potential to reach the sensitivity at the quantum limit of the mechanical vibrations.

  15. Dual versus single Scheimpflug camera for anterior segment analysis: Precision and agreement.

    Science.gov (United States)

    Aramberri, Jaime; Araiz, Luis; Garcia, Ane; Illarramendi, Igor; Olmos, Jaione; Oyanarte, Izaskun; Romay, Amaya; Vigara, Itxaso

    2012-11-01

    To assess the repeatability, reproducibility, and agreement of the Pentacam HR single-camera and Galilei G2 dual-camera Scheimpflug devices in anterior segment analysis. Begitek Clínica Oftalmológica, San Sebastián, Spain. Prospective randomized observational study. Healthy young individuals had 3 consecutive tests by 2 examiners. Analyzed parameters were anterior and posterior cornea simulated keratometry (K), K flat, K steep, astigmatism magnitude and axis, J(0) and J(45) vectors, asphericity, total corneal higher-order wavefront aberrations (root mean square [RMS], coma, trefoil, spherical aberration), central cornea and thinnest-point thicknesses, and anterior chamber depth. Repeatability and reproducibility were evaluated by calculating the within-subject standard deviation (S(w)), some derived coefficients, and the intraclass correlation coefficient. Agreement was assessed with the Bland-Altman method. The single-camera device reproducibility (S(w)) was simulated K, 0.04 diopter (D); J(0), 0.03 D; J(45), 0.04 D; total power, 0.04 D; spherical aberration, 0.02 μm; higher-order aberrations (HOAs), 0.02 μm; central corneal thickness (CCT), 3.39 μm. The dual-camera device S(w) was simulated K, 0.07 D; J(0), 0.13 D; J(45), 0.04 D; total power, 0.08 D; spherical aberration, 0.02 μm; HOAs, 0.11 μm; CCT, 1.36 μm. Agreement was good for most parameters except total corneal power (mean difference 1.58 D ± 0.22 (SD) and HOA RMS (mean difference 0.48 ± 0.19 μm) (both PAramberri is consultant to Costruzione Strumenti Oftalmici, Firenze, Italy. No other author has a financial or proprietary interest in any material or method mentioned. Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

  16. Calculation of precision satellite orbits with nonsingular elements /VOP formulation/

    Science.gov (United States)

    Velez, C. E.; Cefola, P. J.; Long, A. C.; Nimitz, K. S.

    1974-01-01

    Review of some results obtained in an effort to develop efficient, high-precision trajectory computation processes for artificial satellites by optimum selection of the form of the equations of motion of the satellite and the numerical integration method. In particular, the matching of a Gaussian variation-of-parameter (VOP) formulation is considered which is expressed in terms of equinoctial orbital elements and partially decouples the motion of the orbital frame from motion within the orbital frame. The performance of the resulting orbit generators is then compared with the popular classical Cowell/Gauss-Jackson formulation/integrator pair for two distinctly different orbit types - namely, the orbit of the ATS satellite at near-geosynchronous conditions and the near-circular orbit of the GEOS-C satellite at 1000 km.

  17. Precise predictions of H2O line shapes over a wide pressure range using simulations corrected by a single measurement

    Science.gov (United States)

    Ngo, N. H.; Nguyen, H. T.; Tran, H.

    2018-03-01

    In this work, we show that precise predictions of the shapes of H2O rovibrational lines broadened by N2, over a wide pressure range, can be made using simulations corrected by a single measurement. For that, we use the partially-correlated speed-dependent Keilson-Storer (pcsdKS) model whose parameters are deduced from molecular dynamics simulations and semi-classical calculations. This model takes into account the collision-induced velocity-changes effects, the speed dependences of the collisional line width and shift as well as the correlation between velocity and internal-state changes. For each considered transition, the model is corrected by using a parameter deduced from its broadening coefficient measured for a single pressure. The corrected-pcsdKS model is then used to simulate spectra for a wide pressure range. Direct comparisons of the corrected-pcsdKS calculated and measured spectra of 5 rovibrational lines of H2O for various pressures, from 0.1 to 1.2 atm, show very good agreements. Their maximum differences are in most cases well below 1%, much smaller than residuals obtained when fitting the measurements with the Voigt line shape. This shows that the present procedure can be used to predict H2O line shapes for various pressure conditions and thus the simulated spectra can be used to deduce the refined line-shape parameters to complete spectroscopic databases, in the absence of relevant experimental values.

  18. Single-frequency receivers as master permanent stations in GNSS networks: precision and accuracy of the positioning in mixed networks

    Science.gov (United States)

    Dabove, Paolo; Manzino, Ambrogio Maria

    2015-04-01

    The use of GPS/GNSS instruments is a common practice in the world at both a commercial and academic research level. Since last ten years, Continuous Operating Reference Stations (CORSs) networks were born in order to achieve the possibility to extend a precise positioning more than 15 km far from the master station. In this context, the Geomatics Research Group of DIATI at the Politecnico di Torino has carried out several experiments in order to evaluate the achievable precision obtainable with different GNSS receivers (geodetic and mass-market) and antennas if a CORSs network is considered. This work starts from the research above described, in particular focusing the attention on the usefulness of single frequency permanent stations in order to thicken the existing CORSs, especially for monitoring purposes. Two different types of CORSs network are available today in Italy: the first one is the so called "regional network" and the second one is the "national network", where the mean inter-station distances are about 25/30 and 50/70 km respectively. These distances are useful for many applications (e.g. mobile mapping) if geodetic instruments are considered but become less useful if mass-market instruments are used or if the inter-station distance between master and rover increases. In this context, some innovative GNSS networks were developed and tested, analyzing the performance of rover's positioning in terms of quality, accuracy and reliability both in real-time and post-processing approach. The use of single frequency GNSS receivers leads to have some limits, especially due to a limited baseline length, the possibility to obtain a correct fixing of the phase ambiguity for the network and to fix the phase ambiguity correctly also for the rover. These factors play a crucial role in order to reach a positioning with a good level of accuracy (as centimetric o better) in a short time and with an high reliability. The goal of this work is to investigate about the

  19. Precision Optogenetic Tool for Selective Single- and Multiple-Cell Ablation in a Live Animal Model System.

    Science.gov (United States)

    Makhijani, Kalpana; To, Tsz-Leung; Ruiz-González, Rubén; Lafaye, Céline; Royant, Antoine; Shu, Xiaokun

    2017-01-19

    Cell ablation is a strategy to study cell lineage and function during development. Optogenetic methods are an important cell-ablation approach, and we have previously developed a mini singlet oxygen generator (miniSOG) tool that works in the living Caenorhabditis elegans. Here, we use directed evolution to generate miniSOG2, an improved tool for cell ablation via photogenerated reactive oxygen species. We apply miniSOG2 to a far more complex model animal system, Drosophila melanogaster, and demonstrate that it can be used to kill a single neuron in a Drosophila larva. In addition, miniSOG2 is able to photoablate a small group of cells in one of the larval wing imaginal discs, resulting in an adult with one incomplete and one normal wing. We expect miniSOG2 to be a useful optogenetic tool for precision cell ablation at a desired developmental time point in live animals, thus opening a new window into cell origin, fate and function, tissue regeneration, and developmental biology. Published by Elsevier Ltd.

  20. Evaluation of the Single-precision Floatingpoint Vector Add Kernel Using the Intel FPGA SDK for OpenCL

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Zheming [Argonne National Lab. (ANL), Argonne, IL (United States); Yoshii, Kazutomo [Argonne National Lab. (ANL), Argonne, IL (United States); Finkel, Hal [Argonne National Lab. (ANL), Argonne, IL (United States); Cappello, Franck [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-04-20

    Open Computing Language (OpenCL) is a high-level language that enables software programmers to explore Field Programmable Gate Arrays (FPGAs) for application acceleration. The Intel FPGA software development kit (SDK) for OpenCL allows a user to specify applications at a high level and explore the performance of low-level hardware acceleration. In this report, we present the FPGA performance and power consumption results of the single-precision floating-point vector add OpenCL kernel using the Intel FPGA SDK for OpenCL on the Nallatech 385A FPGA board. The board features an Arria 10 FPGA. We evaluate the FPGA implementations using the compute unit duplication and kernel vectorization optimization techniques. On the Nallatech 385A FPGA board, the maximum compute kernel bandwidth we achieve is 25.8 GB/s, approximately 76% of the peak memory bandwidth. The power consumption of the FPGA device when running the kernels ranges from 29W to 42W.

  1. Precision measurements of the top quark pair production cross section in the single lepton channel with the ATLAS experiment

    International Nuclear Information System (INIS)

    Heinrichs, Anna Christine

    2012-01-01

    Two precision measurements of the top quark pair production cross section in the lepton+jets channel are accomplished using data taken by the ATLAS experiment at the Large Hadron Collider at CERN. The data corresponds to proton-proton collisions taken in 2010 and 2011 at a center-of-mass energy of 7 TeV. The measurement using data from 2010 achieves an overall uncertainty of 12%, while the measurement using 2011 data reaches a precision of 6.6%. Both measurements are in good agreement with theoretical predictions in the framework of the Standard Model of particle physics.

  2. Easy-DHPSF open-source software for three-dimensional localization of single molecules with precision beyond the optical diffraction limit.

    Science.gov (United States)

    Lew, Matthew D; von Diezmann, Alexander R S; Moerner, W E

    2013-02-25

    Automated processing of double-helix (DH) microscope images of single molecules (SMs) streamlines the protocol required to obtain super-resolved three-dimensional (3D) reconstructions of ultrastructures in biological samples by single-molecule active control microscopy. Here, we present a suite of MATLAB subroutines, bundled with an easy-to-use graphical user interface (GUI), that facilitates 3D localization of single emitters (e.g. SMs, fluorescent beads, or quantum dots) with precisions of tens of nanometers in multi-frame movies acquired using a wide-field DH epifluorescence microscope. The algorithmic approach is based upon template matching for SM recognition and least-squares fitting for 3D position measurement, both of which are computationally expedient and precise. Overlapping images of SMs are ignored, and the precision of least-squares fitting is not as high as maximum likelihood-based methods. However, once calibrated, the algorithm can fit 15-30 molecules per second on a 3 GHz Intel Core 2 Duo workstation, thereby producing a 3D super-resolution reconstruction of 100,000 molecules over a 20×20×2 μm field of view (processing 128×128 pixels × 20000 frames) in 75 min.

  3. Precise Alignment of Individual Single-Walled Carbon Nanotube Using Dielectrophoresis Method for Development and Fabrication of pH Sensor

    Directory of Open Access Journals (Sweden)

    U. Hashim

    2013-01-01

    Full Text Available Development and fabrication of single-walled carbon nanotube (SWNT based pH sensor were reported. The precise alignment of individual SWNT using dielectrophoresis method between the two microgap electrodes was conducted, and the effects of precise alignment of individual SWNT on impedance, long term stability, and capacitance of the sensor were studied. The pH sensor was fabricated using conventional photolithography and wet etching process. The impedance values were found to decrease in the order of distilled water > pH 10 > pH 5 > pH 3 > air. Without the alignment of SWNT, the capacitances values decreased with increasing of pH values at low frequency. All the impedance and capacitance results were highly repeatable.

  4. Precision manufacturing

    CERN Document Server

    Dornfeld, David

    2008-01-01

    Today there is a high demand for high-precision products. The manufacturing processes are now highly sophisticated and derive from a specialized genre called precision engineering. Precision Manufacturing provides an introduction to precision engineering and manufacturing with an emphasis on the design and performance of precision machines and machine tools, metrology, tooling elements, machine structures, sources of error, precision machining processes and precision process planning. As well as discussing the critical role precision machine design for manufacturing has had in technological developments over the last few hundred years. In addition, the influence of sustainable manufacturing requirements in precision processes is introduced. Drawing upon years of practical experience and using numerous examples and illustrative applications, David Dornfeld and Dae-Eun Lee cover precision manufacturing as it applies to: The importance of measurement and metrology in the context of Precision Manufacturing. Th...

  5. Precision Photothermal Annealing of Nanoporous Gold Thin Films for the Microfabrication of a Single-chip Material Libraries

    Energy Technology Data Exchange (ETDEWEB)

    Harris, C. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Shen, N. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Rubenchik, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Demos, S. G. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Matthews, M. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2015-06-30

    Single-chip material libraries of thin films of nanostructured materials are a promising approach for high throughput studies of structure-property relationship in the fields of physics and biology. Nanoporous gold (np-Au), produced by an alloy corrosion process, is a nanostructured material of specific interest in both these fields. One attractive property of np-Au is its self-similar coarsening behavior by thermally induced surface diffusion. However, traditional heat application techniques for the modification of np-Au are bulk processes that cannot be used to generate a library of different pore sizes on a single chip. Laser micromachining offers an attractive solution to this problem by providing a means to apply energy with high spatial and temporal resolution. In the present study we use finite element multiphysics simulations to predict the effects of laser mode (continuous-wave vs. pulsed) and supporting substrate thermal conductivity on the local np-Au film temperatures during photothermal annealing and subsequently investigate the mechanisms by which the np-Au network is coarsening. Our simulations predict that continuous-wave mode laser irradiation on a silicon supporting substrate supports the widest range of morphologies that can be created through the photothermal annealing of thin film np-Au. Using this result we successfully fabricate a single-chip material library consisting of 81 np-Au samples of 9 different morphologies for use in increased throughput material interaction studies.

  6. Spontaneously formed high-performance charge-transport layers of organic single-crystal semiconductors on precisely synthesized insulating polymers

    Science.gov (United States)

    Makita, Tatsuyuki; Sasaki, Masayuki; Annaka, Tatsuro; Sasaki, Mari; Matsui, Hiroyuki; Mitsui, Chikahiko; Kumagai, Shohei; Watanabe, Shun; Hayakawa, Teruaki; Okamoto, Toshihiro; Takeya, Jun

    2017-04-01

    Charge-transporting semiconductor layers with high carrier mobility and low trap-density, desired for high-performance organic transistors, are spontaneously formed as a result of thermodynamic phase separation from a blend of π-conjugated small molecules and precisely synthesized insulating polymers dissolved in an aromatic solvent. A crystal film grows continuously to the size of centimeters, with the critical conditions of temperature, concentrations, and atmosphere. It turns out that the molecular weight of the insulating polymers plays an essential role in stable film growth and interfacial homogeneity at the phase separation boundary. Fabricating the transistor devices directly at the semiconductor-insulator boundaries, we demonstrate that the mixture of 3,11-didecyldinaphtho[2,3-d:2',3'-d']benzo[1,2-b:4,5-b']dithiophene and poly(methyl methacrylate) with the optimized weight-average molecular weight shows excellent device performances. The spontaneous phase separation with a one-step fabrication process leads to a high mobility up to 10 cm2 V-1 s-1 and a low subthreshold swing of 0.25 V dec-1 even without any surface treatment such as self-assembled monolayer modifications on oxide gate insulators.

  7. Precise orbit and attitude determination using redundant low-cost single-frequency GNSS receivers on a CubeSat

    Science.gov (United States)

    Willi, Daniel; Fisler, Michael; Hollenstein, Christine; Männel, Benjamin; Meindl, Michael; Xu, Hui; Rothacher, Markus

    2016-07-01

    CubETH is a technology demonstration mission aimed at using low-cost commercial-off-the-shelf GNSS receivers for space applications. Precise orbit and attitude determination, on-board as well as in post-processing, are the main mission goals. The one unit cube-satellite is equipped with five GNSS antennas, each of them connected to two u-blox multi-GNSS receivers. The position estimation on the satellite is based on the receiver navigation solution. We show that (1) the proper correction of the ionospheric path delay and (2) the position propagation in the Kalman filter are of uppermost importance. Based on available data from the GRACE and GOCE missions, we show how an adapted Klobuchar model leads to a better estimation of the path delay in low Earth orbits. Based on recent signal-simulator tests, we illustrate how the linear propagation in the receiver Kalman filter leads to systematic errors and exhibit a method for improvement.

  8. Efficient injection from large telescopes into single-mode fibres: Enabling the era of ultra-precision astronomy

    Science.gov (United States)

    Jovanovic, N.; Schwab, C.; Guyon, O.; Lozi, J.; Cvetojevic, N.; Martinache, F.; Leon-Saval, S.; Norris, B.; Gross, S.; Doughty, D.; Currie, T.; Takato, N.

    2017-08-01

    Photonic technologies offer numerous advantages for astronomical instruments such as spectrographs and interferometers owing to their small footprints and diverse range of functionalities. Operating at the diffraction-limit, it is notoriously difficult to efficiently couple such devices directly with large telescopes. We demonstrate that with careful control of both the non-ideal pupil geometry of a telescope and residual wavefront errors, efficient coupling with single-mode devices can indeed be realised. A fibre injection was built within the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument. Light was coupled into a single-mode fibre operating in the near-IR (J - H bands) which was downstream of the extreme adaptive optics system and the pupil apodising optics. A coupling efficiency of 86% of the theoretical maximum limit was achieved at 1550 nm for a diffraction-limited beam in the laboratory, and was linearly correlated with Strehl ratio. The coupling efficiency was constant to within 40% for 84% of the time and >50% for 41% of the time. The laboratory results allow us to forecast that extreme adaptive optics levels of correction (Strehl ratio >90% in H-band) would allow coupling of >67% (of the order of coupling to multimode fibres currently) while standard levels of wavefront correction (Strehl ratio >20% in H-band) would allow coupling of >18%. For Strehl ratios <20%, few-port photonic lanterns become a superior choice but the signal-to-noise, and pixel availability must be considered. These results illustrate a clear path to efficient on-sky coupling into a single-mode fibre, which could be used to realise modal-noise-free radial velocity machines, very-long-baseline optical/near-IR interferometers and/or simply exploit photonic technologies in future instrument design.

  9. N-of-1-pathways MixEnrich: advancing precision medicine via single-subject analysis in discovering dynamic changes of transcriptomes.

    Science.gov (United States)

    Li, Qike; Schissler, A Grant; Gardeux, Vincent; Achour, Ikbel; Kenost, Colleen; Berghout, Joanne; Li, Haiquan; Zhang, Hao Helen; Lussier, Yves A

    2017-05-24

    Transcriptome analytic tools are commonly used across patient cohorts to develop drugs and predict clinical outcomes. However, as precision medicine pursues more accurate and individualized treatment decisions, these methods are not designed to address single-patient transcriptome analyses. We previously developed and validated the N-of-1-pathways framework using two methods, Wilcoxon and Mahalanobis Distance (MD), for personal transcriptome analysis derived from a pair of samples of a single patient. Although, both methods uncover concordantly dysregulated pathways, they are not designed to detect dysregulated pathways with up- and down-regulated genes (bidirectional dysregulation) that are ubiquitous in biological systems. We developed N-of-1-pathways MixEnrich, a mixture model followed by a gene set enrichment test, to uncover bidirectional and concordantly dysregulated pathways one patient at a time. We assess its accuracy in a comprehensive simulation study and in a RNA-Seq data analysis of head and neck squamous cell carcinomas (HNSCCs). In presence of bidirectionally dysregulated genes in the pathway or in presence of high background noise, MixEnrich substantially outperforms previous single-subject transcriptome analysis methods, both in the simulation study and the HNSCCs data analysis (ROC Curves; higher true positive rates; lower false positive rates). Bidirectional and concordant dysregulated pathways uncovered by MixEnrich in each patient largely overlapped with the quasi-gold standard compared to other single-subject and cohort-based transcriptome analyses. The greater performance of MixEnrich presents an advantage over previous methods to meet the promise of providing accurate personal transcriptome analysis to support precision medicine at point of care.

  10. Algorithm and program for precise determination of unit-cell parameters of single crystal taking into account the sample eccentricity

    Science.gov (United States)

    Dudka, A. P.; Smirnova, E. S.; Verin, I. A.; Bolotina, N. B.

    2017-07-01

    A technique has been developed to refine the unit-cell parameters of single crystals with minimization of the influence of instrumental errors on the result. The corresponding computational procedure HuberUB is added to the software package of Huber-5042 diffractometer with a point detector and closedcycle helium cryostat Displex DE-202. The parameters of unit cell, its orientation, the goniometer zero angles, the sample eccentricity, the distances in the goniometer, and the radiation wavelength were refined by the nonlinear least-squares method, which allows imposition of constraints on the unit-cell parameters, depending on the crystal symmetry. The technique is approved on a LuB12 single crystal. The unit-cell parameters are determined in a temperature range of 20-295 K, with an absolute error not larger than 0.0004 Å (the relative error is of 5 × 10-5). The estimates of the unit-cell parameters obtained by the proposed method are evidenced to be unbiased. Some specific features of the behavior of parameters in the ranges of 120-140 and 20-50 K are revealed, which correlate with the anomalies of the physical properties of the crystal.

  11. Self-centering fiber alignment structures for high-precision field installable single-mode fiber connectors

    Science.gov (United States)

    Van Erps, Jürgen; Ebraert, Evert; Gao, Fei; Vervaeke, Michael; Berghmans, Francis; Beri, Stefano; Watté, Jan; Thienpont, Hugo

    2014-05-01

    There is a steady increase in the demand for internet bandwidth, primarily driven by cloud services and high-definition video streaming. Europe's Digital Agenda states the ambitious objective that by 2020 all Europeans should have access to internet at speeds of 30Mb/s or above, with 50% or more of households subscribing to connections of 100Mb/s. Today however, internet access in Europe is mainly based on the first generation of broadband, meaning internet accessed over legacy telephone copper and TV cable networks. In recent years, Fiber-To-The-Home (FTTH) networks have been adopted as a replacement of traditional electrical connections for the `last mile' transmission of information at bandwidths over 1Gb/s. However, FTTH penetration is still very low (FTTH networks. Indeed, the success and adoption of optical access networks critically depend on the quality and reliability of connections between optical fibers. In particular a further reduction of insertion loss of field- installable connectors must be achieved without a significant increase in component cost. This requires precise alignment of fibers that can differ in terms of ellipticity, eccentricity or diameter and seems hardly achievable using today's widespread ferrule-based alignment systems. In this paper, we present a field-installable connector based on deflectable/compressible spring structures, providing a self-centering functionality for the fiber. This way, it can accommodate for possible fiber cladding diameter variations (the tolerance on the cladding diameter of G.652 fiber is typically +/-0.7μm). The mechanical properties of the cantilever are derived through an analytical approximation and a mathematical model of the spring constant, and finite element-based simulations are carried out to find the maximum first principal stress as well as the stress distribution distribution in the fiber alignment structure. Elastic constants of the order of 104N=m are found to be compatible with a proof

  12. Precision Machining

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    This special issue of S¯adhan¯a is devoted to Precision Engineering. Recent progress in this field clearly indicates the transition of precision technology to precision science. Dr. Mer- chant's new theory on the mechanics of metal cutting in 1944 heralded a new approach, moving away from the empirical work of Taylor ...

  13. Chronology of early Archaean granite-greenstone evolution in the Barberton Mountain Land, South Africa, based on precise dating by single zircon evaporation

    Science.gov (United States)

    Kruener, Alfred; Byerly, Gary R.; Lowe, Donald R.

    1991-01-01

    Precise Pb-207/Pb-206 single zircon evaporating ages are reported for low-grade felsic metavolcanic rocks within the Onverwacht and Fig Tree Groups of the Barberton Greenstone Belt (BGB), South Africa, as well as for granitoid plutons bordering the belt. Dacitic tuffs of the Hooggenoeg Formation in the upper part of the Onverwacht Group are shown to yield ages between 3445 + or - 3 and 3416 + or - 5 Ma and to contain older crustal components represented by a 3504 + or - 4 Ma old zircon xenocryst. Fig Tree dacitic tuffs and agglomerates have euhedral zircons between 3259 + or - 3 Ma in age which are interpreted to reflect the time of crystallization. The comagmatic relationships between greenstone felsic volcanic units and the surrounding plutonic suites are keynoted. The data adduced show that the Onverwacht and Fig Tree felsic units have distinctly different ages and thus do not constitute a single, tectonically repeated unit as proposed by others. It is argued that conventional multigrain zircon dating may not accurately identify the time of felsic volcanic activity in ancient greenstones, and that the BGB in the Kaapval craton of southern Africa and greenstones in the Pilbara Block of Western Australia may have been part of a larger crustal unit in early Archaean times.

  14. Why precision?

    Energy Technology Data Exchange (ETDEWEB)

    Bluemlein, Johannes

    2012-05-15

    Precision measurements together with exact theoretical calculations have led to steady progress in fundamental physics. A brief survey is given on recent developments and current achievements in the field of perturbative precision calculations in the Standard Model of the Elementary Particles and their application in current high energy collider data analyses.

  15. Oscillatory Störmer-Cowell methods

    NARCIS (Netherlands)

    P.J. van der Houwen; E. Messina; B.P. Sommeijer (Ben)

    1998-01-01

    textabstractWe consider explicit methods for initial-value problems for special second-order ordinary differential equations where the righthand side does not contain the derivative of ${bf y$ and where the solution components are known to be periodic with frequencies $|omega_j$ lying in a given

  16. Achaean TTG and high alimunia gneisses on Baltic Shield: Precise U-Pb (ID-TIMS) and SHRIMP-II ages on single zircon

    Science.gov (United States)

    Bayanova, Tamara; Morozova, Ludmila; Mitrofanov, Felix; Serov, Pavel; Nitkina, Elena; Fedotov, Dzorzh; Larionov, Alexander

    2014-05-01

    New U-Pb (ID-TIMS) data on single zircon from high alimunia gneisses near Murmansk in the Central-Kola domain gave 3.17 Ga. Core from these zircon population has the age 3695±5 Ma by SHRIMP-II. Time of amphibolites metamorphism was dated with 2753±3 Ma. Achaean gneisses in Monchegorsk ore region were firstly dated in the Central-Kola domain. Single zircon from gneisses in Monchegorsk region which are the basement for Paleoproterozoic PGE layered intrusions with U-Pb ages on zircon and baddeleyite from 2.4-to 2.5 Ga (Bayanova et all, 2009) has 3.16 Ga. Single zircon from gnneisses gave 2776±3 Ma and is considered as amphibolites metamorphism. Voche-Lambina international polygon lies on the boundary between Belomorian mobile block and Central -Kola domain (Morozova et al, 2011). New neoarhaean U-Pb data on single zircon from TTG of polygon yielded 3158.2±8.2. Zircon are characterized by low concentration U and Pb, low U/Th ratio with 0.2. REE diagrams of grey gneisses reflect high fractionation La/Yb>30,encriched by light REE and depleted by heavy Yb<0.6 ppm. Model Sm-Ng ages on the rocks have protolith from with the ages 3.4 to 3.2 Ga, positive ɛNd from +1.29 to +3.3, ISr equals 0.702. Precise (ID-TIMS) age of amphibolites metamorphism has been dated on single zircon with 2704.3±5.9 Ma. In the frame of the Central-Kola domain there is an Ingosersky TTG complex. Firstly U-Pb dating on single zircon from Bt-gneisses reflects 3149±49 Ma. Metamorphic alterations were in 2725.2±2.5 Ma and connected with origin of Amf-Bt gneisses and 2733.6±6.6 with Bt-Amf gneisses. (NItkina et al., 2012). Therefore based on the new data on single zircon from TTG and high alimunia gneisses from Central-Kola domain leads to the long history of continental crust origin in the Baltic or Fennoscandian Shield from 3.16 to 3.7 Ga. We thank to G. Wasserburg for 205 Pb artificial spike, J. Ludden for 91500 and Temora standards, F. Corfu, V. Todt and U. Poller for assistance in the

  17. ‘N-of-1-pathways’ unveils personal deregulated mechanisms from a single pair of RNA-Seq samples: towards precision medicine

    Science.gov (United States)

    Gardeux, Vincent; Achour, Ikbel; Li, Jianrong; Maienschein-Cline, Mark; Li, Haiquan; Pesce, Lorenzo; Parinandi, Gurunadh; Bahroos, Neil; Winn, Robert; Foster, Ian; Garcia, Joe G N; Lussier, Yves A

    2014-01-01

    Background The emergence of precision medicine allowed the incorporation of individual molecular data into patient care. Indeed, DNA sequencing predicts somatic mutations in individual patients. However, these genetic features overlook dynamic epigenetic and phenotypic response to therapy. Meanwhile, accurate personal transcriptome interpretation remains an unmet challenge. Further, N-of-1 (single-subject) efficacy trials are increasingly pursued, but are underpowered for molecular marker discovery. Method ‘N-of-1-pathways’ is a global framework relying on three principles: (i) the statistical universe is a single patient; (ii) significance is derived from geneset/biomodules powered by paired samples from the same patient; and (iii) similarity between genesets/biomodules assesses commonality and differences, within-study and cross-studies. Thus, patient gene-level profiles are transformed into deregulated pathways. From RNA-Seq of 55 lung adenocarcinoma patients, N-of-1-pathways predicts the deregulated pathways of each patient. Results Cross-patient N-of-1-pathways obtains comparable results with conventional genesets enrichment analysis (GSEA) and differentially expressed gene (DEG) enrichment, validated in three external evaluations. Moreover, heatmap and star plots highlight both individual and shared mechanisms ranging from molecular to organ-systems levels (eg, DNA repair, signaling, immune response). Patients were ranked based on the similarity of their deregulated mechanisms to those of an independent gold standard, generating unsupervised clusters of diametric extreme survival phenotypes (p=0.03). Conclusions The N-of-1-pathways framework provides a robust statistical and relevant biological interpretation of individual disease-free survival that is often overlooked in conventional cross-patient studies. It enables mechanism-level classifiers with smaller cohorts as well as N-of-1 studies. Software http://lussierlab.org/publications/N-of-1-pathways

  18. Deviations from plane-wave Mie scattering and precise retrieval of refractive index for a single spherical particle in an optical cavity.

    Science.gov (United States)

    Mason, Bernard J; Walker, Jim S; Reid, Jonathan P; Orr-Ewing, Andrew J

    2014-03-20

    The extinction cross-sections of individual, optically confined aerosol particles with radii of a micrometer or less can, in principle, be measured using cavity ring-down spectroscopy (CRDS). However, when the particle radius is comparable in magnitude to the wavelength of light stored in a high-finesse cavity, the phenomenological cross-section retrieved from a CRDS experiment depends on the location of the particle in the intracavity standing wave and differs from the Mie scattering cross-section for plane-wave irradiation. Using an evaporating 1,2,6-hexanetriol particle of initial radius ∼1.75 μm confined within the 4.5 μm diameter core of a Bessel beam, we demonstrate that the scatter in the retrieved extinction efficiency of a single particle is determined by its lateral motion, which spans a few wavelengths of the intracavity standing wave used for CRDS measurements. Fits of experimental measurements to Mie calculations, modified to account for the intracavity standing wave, allow precise retrieval of the refractive index of 1,2,6-hexanetriol particles (with relative humidity, RH < 10%) of 1.47824 ± 0.00072.

  19. Precision Agriculture

    DEFF Research Database (Denmark)

    Pedersen, Søren Marcus; Lind, Kim Martin Hjorth

    2017-01-01

    This chapter gives an introduction to Precision Agriculture (PA) with a short historic pathway of the development and the status of current available technologies. Part of this description also provides an overview of some of the economic barriers and technical obstacles when applying variable......-steering and Controlled Traffic Systems. Finally, the chapter looks into new developments of autonomous systems with an example of robotic seeding, farm information management in precision agriculture and different methods on the adoption of PA. The last chapter focuses on how PA can fulfil the current policy trends...

  20. Precision genome editing

    DEFF Research Database (Denmark)

    Steentoft, Catharina; Bennett, Eric P; Schjoldager, Katrine Ter-Borch Gram

    2014-01-01

    of glycobiology, primarily due to their low efficiencies, with resultant failure to impose substantial phenotypic consequences upon the final glycosylation products. Here, we review novel nuclease-based precision genome editing techniques enabling efficient and stable gene editing, including gene disruption......Precise and stable gene editing in mammalian cell lines has until recently been hampered by the lack of efficient targeting methods. While different gene silencing strategies have had tremendous impact on many biological fields, they have generally not been applied with wide success in the field...... by introducing single or double-stranded breaks at a defined genomic sequence. We here compare and contrast the different techniques and summarize their current applications, highlighting cases from the field of glycobiology as well as pointing to future opportunities. The emerging potential of precision gene...

  1. Precise models deserve precise measures

    Directory of Open Access Journals (Sweden)

    Benjamin E. Hilbig

    2010-07-01

    Full Text Available The recognition heuristic (RH --- which predicts non-compensatory reliance on recognition in comparative judgments --- has attracted much research and some disagreement, at times. Most studies have dealt with whether or under which conditions the RH is truly used in paired-comparisons. However, even though the RH is a precise descriptive model, there has been less attention concerning the precision of the methods applied to measure RH-use. In the current work, I provide an overview of different measures of RH-use tailored to the paradigm of natural recognition which has emerged as a preferred way of studying the RH. The measures are compared with respect to different criteria --- with particular emphasis on how well they uncover true use of the RH. To this end, both simulations and a re-analysis of empirical data are presented. The results indicate that the adherence rate --- which has been pervasively applied to measure RH-use --- is a severely biased measure. As an alternative, a recently developed formal measurement model emerges as the recommended candidate for assessment of RH-use.

  2. Precision measurement of single atoms strongly coupled to the higher-order transverse modes of a high-finesse optical cavity

    Energy Technology Data Exchange (ETDEWEB)

    Du, Jinjin; Li, Wenfang; Wen, Ruijuan; Li, Gang; Zhang, Pengfei; Zhang, Tiancai [State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Opto-Electronics, Shanxi University, Taiyuan 030006 (China)

    2013-08-19

    We have experimentally demonstrated the strong coupling between single atoms and the higher-order Hermite-Gaussian transverse modes in a high-finesse optical microcavity. Compared to the usual low-order symmetric transverse modes, multiple lobes and the asymmetric spatial pattern of the titled modes provide more information about the motion of single atoms in the cavity. The motional information can be extracted from the measured transmission spectra, which includes the velocities and the positions of the atoms in vertical and off-axis directions. The scheme has great potential in time-resolved atom-cavity microscopy and in tracking the three-dimensional single atom trajectory in real time.

  3. Development and Positioning Accuracy Assessment of Single-Frequency Precise Point Positioning Algorithms by Combining GPS Code-Pseudorange Measurements with Real-Time SSR Corrections

    Directory of Open Access Journals (Sweden)

    Miso Kim

    2017-06-01

    Full Text Available We have developed a suite of real-time precise point positioning programs to process GPS pseudorange observables, and validated their performance through static and kinematic positioning tests. To correct inaccurate broadcast orbits and clocks, and account for signal delays occurring from the ionosphere and troposphere, we applied State Space Representation (SSR error corrections provided by the Seoul Broadcasting System (SBS in South Korea. Site displacements due to solid earth tide loading are also considered for the purpose of improving the positioning accuracy, particularly in the height direction. When the developed algorithm was tested under static positioning, Kalman-filtered solutions produced a root-mean-square error (RMSE of 0.32 and 0.40 m in the horizontal and vertical directions, respectively. For the moving platform, the RMSE was found to be 0.53 and 0.69 m in the horizontal and vertical directions.

  4. Selective Growth of Single-, Double-, and Triple-Walled Carbon Nanotubes through Precise Control of Catalyst Diameter by Radiation-Heated Chemical Vapor Deposition

    Science.gov (United States)

    Taki, Yusuke; Shinohara, Kiyoaki; Kikuchi, Makiko; Tanaka, Akira

    2008-01-01

    Radiation-heated chemical vapor deposition (RHCVD) is a newly developed process which enables the maintenance of narrow catalyst diameter distributions until carbon nanotubes (CNTs) start growing and the synthesis of single-walled carbon nanotube (SWCNT), double-walled carbon nanotube (DWCNT), and triple-walled carbon nanotube (TWCNT) films by changing catalyst diameters. The proportions of specific walled CNTs/as-grown CNTs are as follows: SWCNT/CNT ratio of 100%, DWCNT/CNT ratio of 88% and TWCNT/CNT ratio of 76%. It is clarified that CNT diameter and the number of graphene walls of CNTs are proportional to catalyst diameter.

  5. A precise evaluation of glomerular filtration rate (GFR) in two plasma samples following a single administration of 57Co-B12 vitamin

    International Nuclear Information System (INIS)

    Camargo, E.E.; Rockmann, R.L.; Barreto, T.M.; Eston, T.E.; Papaleo Netto, M.; Carvalho, N.

    1974-01-01

    Through a logarithmic regression performed with the contings of 4 plasma samples withdrawn at 20,40,60 and 80 minutes after a venous injection of vitamin B 12 - 57 Co, the glomerular filtration-rate(GFR) in 11 patients, performing simultaneously the same study with EDTA- 51 Cr in 3 of them, is evaluated. The values obtained through the regression straight line are compared with those given by only 2 points, in the 6 possible combinations: 20 and 40 minutes, 20 and 60 minutes, 20 and 80 minutes, 40 and 60 minutes, 40 and 80 minutes, 60 and 80 minutes. The pair of points obtained at 20 and 80 minutes determined the straight line most similar to the logarithmic regression and as a simplification of the method, the withdraw of only 2 plasma samples, at and 80 minutes after a single injection of vitamin B 12 -57 Co is proposed [pt

  6. Risk-adapted single or fractionated stereotactic high-precision radiotherapy in a pooled series of nonfunctioning pituitary adenomas. High local control and low toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Bostroem, Jan Patrick [MediClin Robert Janker Clinic and MediClin MVZ Bonn, Department of Radiosurgery and Stereotactic Radiotherapy, Bonn (Germany); University Hospital of Bonn, Department of Neurosurgery, Bonn (Germany); Meyer, Almuth [HELIOS Klinikum Erfurt, Department of Endocrinology, Erfurt (Germany); Pintea, Bogdan [University Hospital of Bonn, Department of Neurosurgery, Bonn (Germany); Gerlach, Ruediger [HELIOS Klinikum Erfurt, Department of Neurosurgery, Erfurt (Germany); Surber, Gunnar; Hamm, Klaus [HELIOS Klinikum Erfurt, Department of Radiosurgery, Erfurt (Germany); Lammering, Guido [MediClin Robert Janker Clinic and MediClin MVZ Bonn, Department of Radiosurgery and Stereotactic Radiotherapy, Bonn (Germany); Heinrich-Heine-University of Duesseldorf, Department of Radiotherapy and Radiation Oncology, Duesseldorf (Germany)

    2014-12-15

    The purpose of this work was to evaluate a prospectively initiated two-center protocol of risk-adapted single-fraction (SRS) or fractionated radiotherapy (SRT) in patients with nonsecretory pituitary adenomas (NSA). A total of 73 NSA patients (39 men/34 women) with a median age of 62 years were prospectively included in a treatment protocol of SRS [planning target volume (PTV) < 4 ccm, > 2 mm to optic pathways = low risk] or SRT (PTV ≥ 4 ccm, ≤ 2 mm to optic pathways = high risk) in two Novalis registered centers. Mean tumor volume was 7.02 ccm (range 0.58-57.29 ccm). Based on the protocol guidelines, 5 patients were treated with SRS and 68 patients with SRT. Median follow-up (FU) reached 5 years with 5-year overall survival (OS) of 90.4 % (CI 80.2-95 %) and 5-year local control and progression-free survival rates of 100 % (CI 93.3-100 %) and 90.4 % (CI 80.2-95 %), respectively. A post-SRS/SRT new visual disorder occurred in 2 patients (2.7 %), a new oculomotor nerve palsy in one pre-irradiated patient, in 3 patients (4.1 %) a pre-existing visual disorder improved. New complete hypopituitarism occurred in 4 patients (13.8 %) and in 3 patients (25 %) with pre-existing partial hypopituitarism. Pituitary function in 26 % of patients retained normal. Patients with tumor shrinkage (65.75 %) had a significantly longer FU (p = 0.0093). Multivariate analysis confirmed correlation of new hypopituitarism with duration of FU (p = 0.008) and correlation of new hypopituitarism and tumor volume (p = 0.023). No significant influence factors for occurrence of visual disorders were found. Our SRS/SRT protocol proved to be safe and successful in terms of tumor control and protection of the visual system, especially for large tumors located close to optic pathways. (orig.) [German] Evaluation eines prospektiv angelegten Behandlungsprotokolls einer risikoadaptierten Radiochirurgie (SRS) oder stereotaktischen Radiotherapie (SRT) von Patienten mit hormoninaktiven Hypophysenadenomen

  7. Rapid and precise determination of Sr and Nd isotopic ratios in geological samples from the same filament loading by thermal ionization mass spectrometry employing a single-step separation scheme.

    Science.gov (United States)

    Li, Chao-Feng; Li, Xian-Hua; Li, Qiu-Li; Guo, Jing-Hui; Li, Xiang-Hui; Yang, Yue-Heng

    2012-05-21

    Thermal ionization mass spectrometry (TIMS) offers the excellent precision and accuracy of the Sr and Nd isotopic ratio analysis for geological samples, but this method is labour intensive, expensive and time-consuming. In this study, a new analytical protocol by TIMS is presented that aims at improving analytical efficiency and cutting down experimental cost. Using the single-step cation exchange resin technique, mixed Sr and rare earth elements (REEs) fractions were separated from matrix and evaporated to dryness. Afterwards, mixed Sr+REEs fractions were dissolved and loaded onto the same Re filament using 1 μL of 2 M HCl. Then, Sr and Nd were sequentially measured without venting using TIMS. In contrast to conventional TIMS methods, the merits of this analytical protocol are its cost- and time-saving adaptations. The applicability of our method is evaluated by replicated measurements of (87)Sr/(86)Sr and (143)Nd/(144)Nd for nine international silicate rock reference materials, spanning a wide range of bulk compositions. The typical internal precision in this study is ca. 0.001% (RSE) for (87)Sr/(86)Sr and (143)Nd/(144)Nd; the analytical results obtained for these standard rocks show a good agreement with reported values, indicating the effectiveness of the proposed method. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Analysis of Precision of Activation Analysis Method

    DEFF Research Database (Denmark)

    Heydorn, Kaj; Nørgaard, K.

    1973-01-01

    The precision of an activation-analysis method prescribes the estimation of the precision of a single analytical result. The adequacy of these estimates to account for the observed variation between duplicate results from the analysis of different samples and materials, is tested by the statistic T...

  9. Precision Clock Evaluation Facility

    Data.gov (United States)

    Federal Laboratory Consortium — FUNCTION: Tests and evaluates high-precision atomic clocks for spacecraft, ground, and mobile applications. Supports performance evaluation, environmental testing,...

  10. Positive Pregnancy Tests at Cowell Student Health Center

    Science.gov (United States)

    Dorman, John M.

    1978-01-01

    With the exception of college freshmen, the frequency of unplanned pregnancies at both the undergraduate and graduate levels was unrelated to class, but increased over the time studied, with peaks after vacation periods. (MJB)

  11. Precision machining commercialization

    International Nuclear Information System (INIS)

    1978-01-01

    To accelerate precision machining development so as to realize more of the potential savings within the next few years of known Department of Defense (DOD) part procurement, the Air Force Materials Laboratory (AFML) is sponsoring the Precision Machining Commercialization Project (PMC). PMC is part of the Tri-Service Precision Machine Tool Program of the DOD Manufacturing Technology Five-Year Plan. The technical resources supporting PMC are provided under sponsorship of the Department of Energy (DOE). The goal of PMC is to minimize precision machining development time and cost risk for interested vendors. PMC will do this by making available the high precision machining technology as developed in two DOE contractor facilities, the Lawrence Livermore Laboratory of the University of California and the Union Carbide Corporation, Nuclear Division, Y-12 Plant, at Oak Ridge, Tennessee

  12. submitter LEP precision results

    CERN Document Server

    Kawamoto, T

    2001-01-01

    Precision measurements at LEP are reviewed, with main focus on the electroweak measurements and tests of the Standard Model. Constraints placed by the LEP measurements on possible new physics are also discussed.

  13. NCI Precision Medicine

    Science.gov (United States)

    This illustration represents the National Cancer Institute’s support of research to improve precision medicine in cancer treatment, in which unique therapies treat an individual’s cancer based on specific genetic abnormalities of that person’s tumor.

  14. Laser precision microfabrication

    CERN Document Server

    Sugioka, Koji; Pique, Alberto

    2010-01-01

    Miniaturization and high precision are rapidly becoming a requirement for many industrial processes and products. As a result, there is greater interest in the use of laser microfabrication technology to achieve these goals. This book composed of 16 chapters covers all the topics of laser precision processing from fundamental aspects to industrial applications to both inorganic and biological materials. It reviews the sate of the art of research and technological development in the area of laser processing.

  15. Precision Experiments at LEP

    CERN Document Server

    de Boer, Wim

    2015-01-01

    The Large Electron Positron Collider (LEP) established the Standard Model (SM) of particle physics with unprecedented precision, including all its radiative corrections. These led to predictions for the masses of the top quark and Higgs boson, which were beautifully confirmed later on. After these precision measurements the Nobel Prize in Physics was awarded in 1999 jointly to 't Hooft and Veltman "for elucidating the quantum structure of electroweak interactions in physics". Another hallmark of the LEP results were the precise measurements of the gauge coupling constants, which excluded unification of the forces within the SM, but allowed unification within the supersymmetric extension of the SM. This increased the interest in Supersymmetry (SUSY) and Grand Unified Theories, especially since the SM has no candidate for the elusive dark matter, while Supersymmetry provides an excellent candidate for dark matter. In addition, Supersymmetry removes the quadratic divergencies of the SM and {\\it predicts} the Hig...

  16. A passion for precision

    CERN Multimedia

    CERN. Geneva. Audiovisual Unit

    2006-01-01

    For more than three decades, the quest for ever higher precision in laser spectroscopy of the simple hydrogen atom has inspired many advances in laser, optical, and spectroscopic techniques, culminating in femtosecond laser optical frequency combs as perhaps the most precise measuring tools known to man. Applications range from optical atomic clocks and tests of QED and relativity to searches for time variations of fundamental constants. Recent experiments are extending frequency comb techniques into the extreme ultraviolet. Laser frequency combs can also control the electric field of ultrashort light pulses, creating powerful new tools for the emerging field of attosecond science.

  17. Precision machine design

    CERN Document Server

    Slocum, Alexander H

    1992-01-01

    This book is a comprehensive engineering exploration of all the aspects of precision machine design - both component and system design considerations for precision machines. It addresses both theoretical analysis and practical implementation providing many real-world design case studies as well as numerous examples of existing components and their characteristics. Fast becoming a classic, this book includes examples of analysis techniques, along with the philosophy of the solution method. It explores the physics of errors in machines and how such knowledge can be used to build an error budget for a machine, how error budgets can be used to design more accurate machines.

  18. Precision electron polarimetry

    International Nuclear Information System (INIS)

    Chudakov, E.

    2013-01-01

    A new generation of precise Parity-Violating experiments will require a sub-percent accuracy of electron beam polarimetry. Compton polarimetry can provide such accuracy at high energies, but at a few hundred MeV the small analyzing power limits the sensitivity. Mo/ller polarimetry provides a high analyzing power independent on the beam energy, but is limited by the properties of the polarized targets commonly used. Options for precision polarimetry at 300 MeV will be discussed, in particular a proposal to use ultra-cold atomic hydrogen traps to provide a 100%-polarized electron target for Mo/ller polarimetry

  19. Precision electron polarimetry

    Energy Technology Data Exchange (ETDEWEB)

    Chudakov, Eugene A. [JLAB

    2013-11-01

    A new generation of precise Parity-Violating experiments will require a sub-percent accuracy of electron beam polarimetry. Compton polarimetry can provide such accuracy at high energies, but at a few hundred MeV the small analyzing power limits the sensitivity. M{\\o}ller polarimetry provides a high analyzing power independent on the beam energy, but is limited by the properties of the polarized targets commonly used. Options for precision polarimetry at ~300 MeV will be discussed, in particular a proposal to use ultra-cold atomic hydrogen traps to provide a 100\\%-polarized electron target for M{\\o}ller polarimetry.

  20. Improving Precision of Types

    DEFF Research Database (Denmark)

    Winther, Johnni

    mixing of unrelated types. Secondly, we present an improvement of the type checking algorithm in Java which enables the compiler to detect and ease the use of a common programming idiom called guarded casts. Thirdly, we present an improvement of the precision with which classes generated by a parser...

  1. What is precision medicine?

    Science.gov (United States)

    König, Inke R; Fuchs, Oliver; Hansen, Gesine; von Mutius, Erika; Kopp, Matthias V

    2017-10-01

    The term "precision medicine" has become very popular over recent years, fuelled by scientific as well as political perspectives. Despite its popularity, its exact meaning, and how it is different from other popular terms such as "stratified medicine", "targeted therapy" or "deep phenotyping" remains unclear. Commonly applied definitions focus on the stratification of patients, sometimes referred to as a novel taxonomy, and this is derived using large-scale data including clinical, lifestyle, genetic and further biomarker information, thus going beyond the classical "signs-and-symptoms" approach.While these aspects are relevant, this description leaves open a number of questions. For example, when does precision medicine begin? In which way does the stratification of patients translate into better healthcare? And can precision medicine be viewed as the end-point of a novel stratification of patients, as implied, or is it rather a greater whole?To clarify this, the aim of this paper is to provide a more comprehensive definition that focuses on precision medicine as a process. It will be shown that this proposed framework incorporates the derivation of novel taxonomies and their role in healthcare as part of the cycle, but also covers related terms. Copyright ©ERS 2017.

  2. Levitation Linear Motors for Precision Positioning

    Science.gov (United States)

    Trumper, David L.

    The author has been active in the development of levitation devices for precision positioning during the last 18 years. Principal among the techniques studied has been the use of two-force or levitation linear motors. These motors have been designed into stages for precision positioning in lithography, scanned probe microscopy, and other precision measurement systems. In such devices, the use of levitation linear motors allows the control of six stage degrees of freedom to nanometer resolution with a single moving part. This paper presents an overview of the operating principles, electromagnetic configurations, and system level performance of levitation linear motors for precision applications. The configuration of such motors is most commonly an iron-free permanent magnet array in the Halbach configuration which is driven by an iron-free multiphase coil set. By properly choosing the phase drive currents, forces in levitation and translation can be controlled. This opens possibilities for novel positioning system configurations and performance capabilities.

  3. Precision thermometry and the quantum speed limit

    Science.gov (United States)

    Campbell, Steve; Genoni, Marco G.; Deffner, Sebastian

    2018-04-01

    We assess precision thermometry for an arbitrary single quantum system. For a d-dimensional harmonic system we show that the gap sets a single temperature that can be optimally estimated. Furthermore, we establish a simple linear relationship between the gap and this temperature, and show that the precision exhibits a quadratic relationship. We extend our analysis to explore systems with arbitrary spectra, showing that exploiting anharmonicity and degeneracy can greatly enhance the precision of thermometry. Finally, we critically assess the dynamical features of two thermometry protocols for a two level system. By calculating the quantum speed limit we find that, despite the gap fixing a preferred temperature to probe, there is no evidence of this emerging in the dynamical features.

  4. Precision spectroscopy of trapped radioactive radium ions

    NARCIS (Netherlands)

    Giri, G. S.; Versolato, O. O.; Wansbeek, L. W.; van den Berg, J. E.; van der Hoek, D. J.; Jungmann, K.; Kruithof, W. L.; Onderwater, C. J. G.; Sahoo, B. K.; Santra, B.; Shidling, P. D.; Timmermans, R. G. E.; Willmann, L.; Wilschut, H. W.

    Atomic parity violation (APV) can be measured in a single Ra(+) ion, enabling a precise measurement of the electroweak mixing angle in the Standard Model of particle physics at low momentum transfer. This provides sensitivity to new particles such as extra Z(0) bosons or leptoquarks. The Weinberg

  5. Precision Polarization of Neutrons

    Science.gov (United States)

    Martin, Elise; Barron-Palos, Libertad; Couture, Aaron; Crawford, Christopher; Chupp, Tim; Danagoulian, Areg; Estes, Mary; Hona, Binita; Jones, Gordon; Klein, Andi; Penttila, Seppo; Sharma, Monisha; Wilburn, Scott

    2009-05-01

    Determining polarization of a cold neutron beam to high precision is required for the next generation neutron decay correlation experiments at the SNS, such as the proposed abBA and PANDA experiments. Precision polarimetry measurements were conducted at Los Alamos National Laboratory with the goal of determining the beam polarization to the level of 10-3 or better. The cold neutrons from FP12 were polarized using optically polarized ^3He gas as a spin filter, which has a highly spin-dependent absorption cross section. A second ^ 3He spin filter was used to analyze the neutron polarization after passing through a resonant RF spin rotator. A discussion of the experiment and results will be given.

  6. A passion for precision

    CERN Multimedia

    CERN. Geneva

    2006-01-01

    For more than three decades, the quest for ever higher precision in laser spectroscopy of the simple hydrogen atom has inspired many advances in laser, optical, and spectroscopic techniques, culminating in femtosecond laser optical frequency combs  as perhaps the most precise measuring tools known to man. Applications range from optical atomic clocks and tests of QED and relativity to searches for time variations of fundamental constants. Recent experiments are extending frequency comb techniques into the extreme ultraviolet. Laser frequency combs can also control the electric field of ultrashort light pulses, creating powerful new tools for the emerging field of attosecond science.Organiser(s): L. Alvarez-Gaume / PH-THNote: * Tea & coffee will be served at 16:00.

  7. Precision electroweak measurements

    International Nuclear Information System (INIS)

    Demarteau, M.

    1996-11-01

    Recent electroweak precision measurements fro e + e - and p anti p colliders are presented. Some emphasis is placed on the recent developments in the heavy flavor sector. The measurements are compared to predictions from the Standard Model of electroweak interactions. All results are found to be consistent with the Standard Model. The indirect constraint on the top quark mass from all measurements is in excellent agreement with the direct m t measurements. Using the world's electroweak data in conjunction with the current measurement of the top quark mass, the constraints on the Higgs' mass are discussed

  8. Ultra-precision bearings

    CERN Document Server

    Wardle, F

    2015-01-01

    Ultra-precision bearings can achieve extreme accuracy of rotation, making them ideal for use in numerous applications across a variety of fields, including hard disk drives, roundness measuring machines and optical scanners. Ultraprecision Bearings provides a detailed review of the different types of bearing and their properties, as well as an analysis of the factors that influence motion error, stiffness and damping. Following an introduction to basic principles of motion error, each chapter of the book is then devoted to the basic principles and properties of a specific type of bearin

  9. Automatic titrator for high precision plutonium assay

    International Nuclear Information System (INIS)

    Jackson, D.D.; Hollen, R.M.

    1986-01-01

    Highly precise assay of plutonium metal is required for accountability measurements. We have developed an automatic titrator for this determination which eliminates analyst bias and requires much less analyst time. The analyst is only required to enter sample data and start the titration. The automated instrument titrates the sample, locates the end point, and outputs the results as a paper tape printout. Precision of the titration is less than 0.03% relative standard deviation for a single determination at the 250-mg plutonium level. The titration time is less than 5 min

  10. Precision measurements in supersymmetry

    Energy Technology Data Exchange (ETDEWEB)

    Feng, Johnathan Lee [Stanford Univ., CA (United States)

    1995-05-01

    Supersymmetry is a promising framework in which to explore extensions of the standard model. If candidates for supersymmetric particles are found, precision measurements of their properties will then be of paramount importance. The prospects for such measurements and their implications are the subject of this thesis. If charginos are produced at the LEP II collider, they are likely to be one of the few available supersymmetric signals for many years. The author considers the possibility of determining fundamental supersymmetry parameters in such a scenario. The study is complicated by the dependence of observables on a large number of these parameters. He proposes a straightforward procedure for disentangling these dependences and demonstrate its effectiveness by presenting a number of case studies at representative points in parameter space. In addition to determining the properties of supersymmetric particles, precision measurements may also be used to establish that newly-discovered particles are, in fact, supersymmetric. Supersymmetry predicts quantitative relations among the couplings and masses of superparticles. The author discusses tests of such relations at a future e{sup +}e{sup {minus}} linear collider, using measurements that exploit the availability of polarizable beams. Stringent tests of supersymmetry from chargino production are demonstrated in two representative cases, and fermion and neutralino processes are also discussed.

  11. Precision Joining Center

    Science.gov (United States)

    Powell, J. W.; Westphal, D. A.

    1991-08-01

    A workshop to obtain input from industry on the establishment of the Precision Joining Center (PJC) was held on July 10-12, 1991. The PJC is a center for training Joining Technologists in advanced joining techniques and concepts in order to promote the competitiveness of U.S. industry. The center will be established as part of the DOE Defense Programs Technology Commercialization Initiative, and operated by EG&G Rocky Flats in cooperation with the American Welding Society and the Colorado School of Mines Center for Welding and Joining Research. The overall objectives of the workshop were to validate the need for a Joining Technologists to fill the gap between the welding operator and the welding engineer, and to assure that the PJC will train individuals to satisfy that need. The consensus of the workshop participants was that the Joining Technologist is a necessary position in industry, and is currently used, with some variation, by many companies. It was agreed that the PJC core curriculum, as presented, would produce a Joining Technologist of value to industries that use precision joining techniques. The advantage of the PJC would be to train the Joining Technologist much more quickly and more completely. The proposed emphasis of the PJC curriculum on equipment intensive and hands-on training was judged to be essential.

  12. Precision Medicine in Cancer Treatment

    Science.gov (United States)

    Precision medicine helps doctors select cancer treatments that are most likely to help patients based on a genetic understanding of their disease. Learn about the promise of precision medicine and the role it plays in cancer treatment.

  13. Precise Point Positioning

    DEFF Research Database (Denmark)

    Zhang, Xiaohong

    performance of point positioning for kinematic applications, the precise point positioning attracted a lot of attention and opened a new alternative door to kinematic positioning. In this report different tests have been done to evaluate the ability and accuracy of the software TriP in the kinematic...... and static case by using internal consistency (residuals, RMS, repeatability etc.), known coordinates, ground truth and double-differenced solutions. The kinematic GPS positioning accuracy using four different software systems has been investigated and tested by comparing the degree of agreement between...... the airborne lidar system misalignment angle by automating the matching of lidar data with ground truth. Kinematic GPS positioning has been widely used, but the available commercial software systems are normally only suitable for the short or medium range kinematic baseline. However, in polar areas, airborne...

  14. Precision markedly attenuates repetitive lift capacity.

    Science.gov (United States)

    Collier, Brooke R; Holland, Laura; McGhee, Deirdre; Sampson, John A; Bell, Alison; Stapley, Paul J; Groeller, Herbert

    2014-01-01

    This study investigated the effect of precision on time to task failure in a repetitive whole-body manual handling task. Twelve participants were required to repetitively lift a box weighing 65% of their single repetition maximum to shoulder height using either precise or unconstrained box placement. Muscle activity, forces exerted at the ground, 2D body kinematics, box acceleration and psychophysical measures of performance were recorded until task failure was reached. With precision, time to task failure for repetitive lifting was reduced by 72%, whereas the duration taken to complete a single lift and anterior deltoid muscle activation increased by 39% and 25%, respectively. Yet, no significant difference was observed in ratings of perceived exertion or heart rate at task failure. In conclusion, our results suggest that when accuracy is a characteristic of a repetitive manual handling task, physical work capacity will decline markedly. The capacity to lift repetitively to shoulder height was reduced by 72% when increased accuracy was required to place a box upon a shelf. Lifting strategy and muscle activity were also modified, confirming practitioners should take into consideration movement precision when evaluating the demands of repetitive manual handling tasks.

  15. Precision Medicine in Cardiovascular Diseases

    Directory of Open Access Journals (Sweden)

    Yan Liu

    2017-02-01

    Full Text Available Since President Obama announced the Precision Medicine Initiative in the United States, more and more attention has been paid to precision medicine. However, clinicians have already used it to treat conditions such as cancer. Many cardiovascular diseases have a familial presentation, and genetic variants are associated with the prevention, diagnosis, and treatment of cardiovascular diseases, which are the basis for providing precise care to patients with cardiovascular diseases. Large-scale cohorts and multiomics are critical components of precision medicine. Here we summarize the application of precision medicine to cardiovascular diseases based on cohort and omic studies, and hope to elicit discussion about future health care.

  16. Precisely Tracking Childhood Death.

    Science.gov (United States)

    Farag, Tamer H; Koplan, Jeffrey P; Breiman, Robert F; Madhi, Shabir A; Heaton, Penny M; Mundel, Trevor; Ordi, Jaume; Bassat, Quique; Menendez, Clara; Dowell, Scott F

    2017-07-01

    Little is known about the specific causes of neonatal and under-five childhood death in high-mortality geographic regions due to a lack of primary data and dependence on inaccurate tools, such as verbal autopsy. To meet the ambitious new Sustainable Development Goal 3.2 to eliminate preventable child mortality in every country, better approaches are needed to precisely determine specific causes of death so that prevention and treatment interventions can be strengthened and focused. Minimally invasive tissue sampling (MITS) is a technique that uses needle-based postmortem sampling, followed by advanced histopathology and microbiology to definitely determine cause of death. The Bill & Melinda Gates Foundation is supporting a new surveillance system called the Child Health and Mortality Prevention Surveillance network, which will determine cause of death using MITS in combination with other information, and yield cause-specific population-based mortality rates, eventually in up to 12-15 sites in sub-Saharan Africa and south Asia. However, the Gates Foundation funding alone is not enough. We call on governments, other funders, and international stakeholders to expand the use of pathology-based cause of death determination to provide the information needed to end preventable childhood mortality.

  17. Precise Truss Assembly Using Commodity Parts and Low Precision Welding

    Science.gov (United States)

    Komendera, Erik; Reishus, Dustin; Dorsey, John T.; Doggett, W. R.; Correll, Nikolaus

    2014-01-01

    Hardware and software design and system integration for an intelligent precision jigging robot (IPJR), which allows high precision assembly using commodity parts and low-precision bonding, is described. Preliminary 2D experiments that are motivated by the problem of assembling space telescope optical benches and very large manipulators on orbit using inexpensive, stock hardware and low-precision welding are also described. An IPJR is a robot that acts as the precise "jigging", holding parts of a local structure assembly site in place, while an external low precision assembly agent cuts and welds members. The prototype presented in this paper allows an assembly agent (for this prototype, a human using only low precision tools), to assemble a 2D truss made of wooden dowels to a precision on the order of millimeters over a span on the order of meters. The analysis of the assembly error and the results of building a square structure and a ring structure are discussed. Options for future work, to extend the IPJR paradigm to building in 3D structures at micron precision are also summarized.

  18. Precision Medicine in Cardiovascular Diseases

    OpenAIRE

    Yan Liu; Jie Du

    2017-01-01

    Since President Obama announced the Precision Medicine Initiative in the United States, more and more attention has been paid to precision medicine. However, clinicians have already used it to treat conditions such as cancer. Many cardiovascular diseases have a familial presentation, and genetic variants are associated with the prevention, diagnosis, and treatment of cardiovascular diseases, which are the basis for providing precise care to patients with cardiovascular diseases. Large-scale c...

  19. Reliable low precision simulations in land surface models

    Science.gov (United States)

    Dawson, Andrew; Düben, Peter D.; MacLeod, David A.; Palmer, Tim N.

    2017-12-01

    Weather and climate models must continue to increase in both resolution and complexity in order that forecasts become more accurate and reliable. Moving to lower numerical precision may be an essential tool for coping with the demand for ever increasing model complexity in addition to increasing computing resources. However, there have been some concerns in the weather and climate modelling community over the suitability of lower precision for climate models, particularly for representing processes that change very slowly over long time-scales. These processes are difficult to represent using low precision due to time increments being systematically rounded to zero. Idealised simulations are used to demonstrate that a model of deep soil heat diffusion that fails when run in single precision can be modified to work correctly using low precision, by splitting up the model into a small higher precision part and a low precision part. This strategy retains the computational benefits of reduced precision whilst preserving accuracy. This same technique is also applied to a full complexity land surface model, resulting in rounding errors that are significantly smaller than initial condition and parameter uncertainties. Although lower precision will present some problems for the weather and climate modelling community, many of the problems can likely be overcome using a straightforward and physically motivated application of reduced precision.

  20. Precision electroweak measurement at LEP

    CERN Document Server

    Saeki, T

    2002-01-01

    LEP started in 1989 and finished its operation in November 2000. The four experiments of LEP, ALEPH, DELPHI, L3 and OPAL, collected data and have been performing series of electroweak (EW) precision measurements. This article presents current status of the EW precision measurements at LEP. (8 refs).

  1. A precision pulser for main ring extraction

    International Nuclear Information System (INIS)

    Dinkel, J.; Biggs, J.

    1985-01-01

    A pulser has been designed to produce a 14 Hz sinusoid current pulse at a 2 s rate with peak amplitudes from 400 amps to 3750 amps, and a long term stability of + or -400 mA. Short term stability is achieved by the use of a precision voltage regulator for the capacitor bank. This voltage regulator uses gate turnoff thyristors to control the charging current to the 13 mF capacitor bank. Load current is monitored with a precision dc current transductor. The peak value is read into a single chip microcomputer programmed to act as a digital regulator. The microcomputer calculates reference values for the capacitor bank charging supply and the capacitor bank voltage regulator

  2. Precision Oncology: Between Vaguely Right and Precisely Wrong.

    Science.gov (United States)

    Brock, Amy; Huang, Sui

    2017-12-01

    Precision Oncology seeks to identify and target the mutation that drives a tumor. Despite its straightforward rationale, concerns about its effectiveness are mounting. What is the biological explanation for the "imprecision?" First, Precision Oncology relies on indiscriminate sequencing of genomes in biopsies that barely represent the heterogeneous mix of tumor cells. Second, findings that defy the orthodoxy of oncogenic "driver mutations" are now accumulating: the ubiquitous presence of oncogenic mutations in silent premalignancies or the dynamic switching without mutations between various cell phenotypes that promote progression. Most troublesome is the observation that cancer cells that survive treatment still will have suffered cytotoxic stress and thereby enter a stem cell-like state, the seeds for recurrence. The benefit of "precision targeting" of mutations is inherently limited by this counterproductive effect. These findings confirm that there is no precise linear causal relationship between tumor genotype and phenotype, a reminder of logician Carveth Read's caution that being vaguely right may be preferable to being precisely wrong. An open-minded embrace of the latest inconvenient findings indicating nongenetic and "imprecise" phenotype dynamics of tumors as summarized in this review will be paramount if Precision Oncology is ultimately to lead to clinical benefits. Cancer Res; 77(23); 6473-9. ©2017 AACR . ©2017 American Association for Cancer Research.

  3. 0011-0030.Single Precision and Double Precision RepresenationIn ...

    Indian Academy of Sciences (India)

    error. The page your are looking for can not be found! Please check the link or use the navigation bar at the top. YouTube; Twitter; Facebook; Blog. Academy News. IAS Logo. Theory Of Evolution. Posted on 23 January 2018. Joint Statement by the Three Science Academies of India on the teaching of the theory of evolution

  4. Precision frequency measurements with interferometric weak values

    International Nuclear Information System (INIS)

    Starling, David J.; Dixon, P. Ben; Jordan, Andrew N.; Howell, John C.

    2010-01-01

    We demonstrate an experiment which utilizes a Sagnac interferometer to measure a change in optical frequency of 129 ± 7 kHz/√(Hz) with only 2 mW of continuous-wave, single-mode input power. We describe the measurement of a weak value and show how even higher-frequency sensitivities may be obtained over a bandwidth of several nanometers. This technique has many possible applications, such as precision relative frequency measurements and laser locking without the use of atomic lines.

  5. How GNSS Enables Precision Farming

    Science.gov (United States)

    2014-12-01

    Precision farming: Feeding a Growing Population Enables Those Who Feed the World. Immediate and Ongoing Needs - population growth (more to feed) - urbanization (decrease in arable land) Double food production by 2050 to meet world demand. To meet thi...

  6. Lung Cancer Precision Medicine Trials

    Science.gov (United States)

    Patients with lung cancer are benefiting from the boom in targeted and immune-based therapies. With a series of precision medicine trials, NCI is keeping pace with the rapidly changing treatment landscape for lung cancer.

  7. Spike timing precision in the visual front-end

    OpenAIRE

    Borghuis, B.G. (Bart Gerard)

    2003-01-01

    This thesis describes a series of investigations into the reliability of neural responses in the primary visual pathway. The results described in subsequent chapters are primarily based on extracellular recordings from single neurons in anaesthetized cats and area MT of an awake monkey, and computational model analysis. Comparison of spike timing precision in recorded and Poisson-simulated spike trains shows that spike timing in the front-end visual system is considerably more precise than on...

  8. System and method for high precision isotope ratio destructive analysis

    Science.gov (United States)

    Bushaw, Bruce A; Anheier, Norman C; Phillips, Jon R

    2013-07-02

    A system and process are disclosed that provide high accuracy and high precision destructive analysis measurements for isotope ratio determination of relative isotope abundance distributions in liquids, solids, and particulate samples. The invention utilizes a collinear probe beam to interrogate a laser ablated plume. This invention provides enhanced single-shot detection sensitivity approaching the femtogram range, and isotope ratios that can be determined at approximately 1% or better precision and accuracy (relative standard deviation).

  9. Environment-assisted precision measurement

    DEFF Research Database (Denmark)

    Goldstein, G.; Cappellaro, P.; Maze, J. R.

    2011-01-01

    We describe a method to enhance the sensitivity of precision measurements that takes advantage of the environment of a quantum sensor to amplify the response of the sensor to weak external perturbations. An individual qubit is used to sense the dynamics of surrounding ancillary qubits, which are ...... achieves nearly Heisenberg-limited precision measurement, using a novel class of entangled states. We discuss specific applications to improve clock sensitivity using trapped ions and magnetic sensing based on electronic spins in diamond...

  10. FROM PERSONALIZED TO PRECISION MEDICINE

    Directory of Open Access Journals (Sweden)

    K. V. Raskina

    2017-01-01

    Full Text Available The need to maintain a high quality of life against a backdrop of its inevitably increasing duration is one of the main problems of modern health care. The concept of "right drug to the right patient at the right time", which at first was bearing the name "personalized", is currently unanimously approved by international scientific community as "precision medicine". Precision medicine takes all the individual characteristics into account: genes diversity, environment, lifestyles, and even bacterial microflora and also involves the use of the latest technological developments, which serves to ensure that each patient gets assistance fitting his state best. In the United States, Canada and France national precision medicine programs have already been submitted and implemented. The aim of this review is to describe the dynamic integration of precision medicine methods into routine medical practice and life of modern society. The new paradigm prospects description are complemented by figures, proving the already achieved success in the application of precise methods for example, the targeted therapy of cancer. All in all, the presence of real-life examples, proving the regularity of transition to a new paradigm, and a wide range  of technical and diagnostic capabilities available and constantly evolving make the all-round transition to precision medicine almost inevitable.

  11. Precision Rescue Behavior in North American Ants

    Directory of Open Access Journals (Sweden)

    Katherine Taylor

    2013-07-01

    Full Text Available Altruistic behavior, in which one individual provides aid to another at some cost to itself, is well documented. However, some species engage in a form of altruism, called rescue, that places the altruist in immediate danger. Here we investigate one such example, namely rescuing victims captured by predators. In a field experiment with two North American ant species, Tetramorium sp. E and Prenolepis imparis, individuals were held in artificial snares simulating capture. T. sp. E, but not P. imparis, exhibited digging, pulling, and snare biting, the latter precisely targeted to the object binding the victim. These results are the first to document precision rescue in a North American ant species; moreover, unlike rescue in other ants, T. sp. E rescues conspecifics from different colonies, mirroring their atypical social behavior, namely the lack of aggression between non-nestmate (heterocolonial conspecifics. In a second, observational study designed to demonstrate rescue from an actual predator, T. sp. E victims were dropped into an antlion's pit and the behavior of a single rescuer was observed. Results showed that T. sp. E not only attempted to release the victim, but also risked attacking the predator, suggesting that precision rescue may play an important role in this species' antipredator behavior.

  12. Precise Point Positioning in the Airborne Mode

    Science.gov (United States)

    El-Mowafy, Ahmed

    2011-01-01

    The Global Positioning System (GPS) is widely used for positioning in the airborne mode such as in navigation as a supplementary system and for geo-referencing of cameras in mapping and surveillance by aircrafts and Unmanned Aerial Vehicles (UAV). The Precise Point Positioning (PPP) approach is an attractive positioning approach based on processing of un-differenced observations from a single GPS receiver. It employs precise satellite orbits and satellite clock corrections. These data can be obtained via the internet from several sources, e.g. the International GNSS Service (IGS). The data can also broadcast from satellites, such as via the LEX signal of the new Japanese satellite system QZSS. The PPP can achieve positioning precision and accuracy at the sub-decimetre level. In this paper, the functional and stochastic mathematical modelling used in PPP is discussed. Results of applying the PPP method in an airborne test using a small fixed-wing aircraft are presented. To evaluate the performance of the PPP approach, a reference trajectory was established by differential positioning of the same GPS observations with data from a ground reference station. The coordinate results from the two approaches, PPP and differential positioning, were compared and statistically evaluated. For the test at hand, positioning accuracy at the cm-to-decimetre was achieved for latitude and longitude coordinates and doubles that value for height estimation.

  13. Error bounds from extra precise iterative refinement

    Energy Technology Data Exchange (ETDEWEB)

    Demmel, James; Hida, Yozo; Kahan, William; Li, Xiaoye S.; Mukherjee, Soni; Riedy, E. Jason

    2005-02-07

    We present the design and testing of an algorithm for iterative refinement of the solution of linear equations, where the residual is computed with extra precision. This algorithm was originally proposed in the 1960s [6, 22] as a means to compute very accurate solutions to all but the most ill-conditioned linear systems of equations. However two obstacles have until now prevented its adoption in standard subroutine libraries like LAPACK: (1) There was no standard way to access the higher precision arithmetic needed to compute residuals, and (2) it was unclear how to compute a reliable error bound for the computed solution. The completion of the new BLAS Technical Forum Standard [5] has recently removed the first obstacle. To overcome the second obstacle, we show how a single application of iterative refinement can be used to compute an error bound in any norm at small cost, and use this to compute both an error bound in the usual infinity norm, and a componentwise relative error bound. We report extensive test results on over 6.2 million matrices of dimension 5, 10, 100, and 1000. As long as a normwise (resp. componentwise) condition number computed by the algorithm is less than 1/max{l_brace}10,{radical}n{r_brace} {var_epsilon}{sub w}, the computed normwise (resp. componentwise) error bound is at most 2 max{l_brace}10,{radical}n{r_brace} {center_dot} {var_epsilon}{sub w}, and indeed bounds the true error. Here, n is the matrix dimension and w is single precision roundoff error. For worse conditioned problems, we get similarly small correct error bounds in over 89.4% of cases.

  14. Ultrafast, high precision gated integrator

    Energy Technology Data Exchange (ETDEWEB)

    Wang, X.

    1995-01-01

    An ultrafast, high precision gated integrator has been developed by introducing new design approaches that overcome the problems associated with earlier gated integrator circuits. The very high speed is evidenced by the output settling time of less than 50 ns and 20 MHz input pulse rate. The very high precision is demonstrated by the total output offset error of less than 0.2mV and the output droop rate of less than 10{mu}V/{mu}s. This paper describes the theory of this new gated integrator circuit operation. The completed circuit test results are presented.

  15. Precision agriculture and food security.

    Science.gov (United States)

    Gebbers, Robin; Adamchuk, Viacheslav I

    2010-02-12

    Precision agriculture comprises a set of technologies that combines sensors, information systems, enhanced machinery, and informed management to optimize production by accounting for variability and uncertainties within agricultural systems. Adapting production inputs site-specifically within a field and individually for each animal allows better use of resources to maintain the quality of the environment while improving the sustainability of the food supply. Precision agriculture provides a means to monitor the food production chain and manage both the quantity and quality of agricultural produce.

  16. Sensing technologies for precision irrigation

    CERN Document Server

    Ćulibrk, Dubravko; Minic, Vladan; Alonso Fernandez, Marta; Alvarez Osuna, Javier; Crnojevic, Vladimir

    2014-01-01

    This brief provides an overview of state-of-the-art sensing technologies relevant to the problem of precision irrigation, an emerging field within the domain of precision agriculture. Applications of wireless sensor networks, satellite data and geographic information systems in the domain are covered. This brief presents the basic concepts of the technologies and emphasizes the practical aspects that enable the implementation of intelligent irrigation systems. The authors target a broad audience interested in this theme and organize the content in five chapters, each concerned with a specific technology needed to address the problem of optimal crop irrigation. Professionals and researchers will find the text a thorough survey with practical applications.

  17. Spin and precision electroweak physics

    International Nuclear Information System (INIS)

    Marciano, W.J.

    1993-01-01

    A perspective on fundamental parameters and precision tests of the Standard Model is given. Weak neutral current reactions are discussed with emphasis on those processes involving (polarized) electrons. The role of electroweak radiative corrections in determining the top quark mass and probing for ''new physics'' is described

  18. Precision Machining Technology. Curriculum Guide.

    Science.gov (United States)

    Idaho State Dept. of Education, Boise. Div. of Vocational Education.

    This curriculum guide was developed from a Technical Committee Report prepared with the assistance of industry personnel and containing a Task List which is the basis of the guide. It presents competency-based program standards for courses in precision machining technology and is part of the Idaho Vocational Curriculum Guide Project, a cooperative…

  19. Spin and precision electroweak physics

    Energy Technology Data Exchange (ETDEWEB)

    Marciano, W.J. [Brookhaven National Lab., Upton, NY (United States)

    1994-12-01

    A perspective on fundamental parameters and precision tests of the Standard Model is given. Weak neutral current reactions are discussed with emphasis on those processes involving (polarized) electrons. The role of electroweak radiative corrections in determining the top quark mass and probing for {open_quotes}new physics{close_quotes} is described.

  20. Precision Tests of Electroweak Interactions

    CERN Document Server

    Akhundov, Arif

    2008-01-01

    The status of the precision tests of the electroweak interactions is reviewed in this paper. An emphasis is put on the Standard Model analysis based on measurements at LEP/SLC and the Tevatron. The results of the measurements of the electroweak mixing angle in the NuTeV experiment and the future prospects are discussed.

  1. Future challenges for precision QCD

    CERN Document Server

    2016-01-01

    Precision measurements at Run II of the LHC continue to demand smaller theoretical uncertainties. In this meeting we aim to bring together experts in the field to discuss current issues in the theoretical models. Topics of particular interest are Higgs and Top quark physics, new techniques for infrared subtraction and loop integrals as well as fixed order and parton shower matching beyond NLO.

  2. The road to precision oncology

    OpenAIRE

    Biankin, Andrew V.

    2017-01-01

    The ultimate goal of precision medicine is to use population-based molecular, clinical and other data to make individually tailored clinical decisions for patients, although the path to achieving this goal is not entirely clear. A new study shows how knowledge banks of patient data can be used to make individual treatment decisions in acute myeloid leukemia.

  3. Rapid whole genome sequencing and precision neonatology.

    Science.gov (United States)

    Petrikin, Joshua E; Willig, Laurel K; Smith, Laurie D; Kingsmore, Stephen F

    2015-12-01

    Traditionally, genetic testing has been too slow or perceived to be impractical to initial management of the critically ill neonate. Technological advances have led to the ability to sequence and interpret the entire genome of a neonate in as little as 26 h. As the cost and speed of testing decreases, the utility of whole genome sequencing (WGS) of neonates for acute and latent genetic illness increases. Analyzing the entire genome allows for concomitant evaluation of the currently identified 5588 single gene diseases. When applied to a select population of ill infants in a level IV neonatal intensive care unit, WGS yielded a diagnosis of a causative genetic disease in 57% of patients. These diagnoses may lead to clinical management changes ranging from transition to palliative care for uniformly lethal conditions for alteration or initiation of medical or surgical therapy to improve outcomes in others. Thus, institution of 2-day WGS at time of acute presentation opens the possibility of early implementation of precision medicine. This implementation may create opportunities for early interventional, frequently novel or off-label therapies that may alter disease trajectory in infants with what would otherwise be fatal disease. Widespread deployment of rapid WGS and precision medicine will raise ethical issues pertaining to interpretation of variants of unknown significance, discovery of incidental findings related to adult onset conditions and carrier status, and implementation of medical therapies for which little is known in terms of risks and benefits. Despite these challenges, precision neonatology has significant potential both to decrease infant mortality related to genetic diseases with onset in newborns and to facilitate parental decision making regarding transition to palliative care. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Studies in precise neutron optics at JAERI

    International Nuclear Information System (INIS)

    Tomimitsu, Hiroshi

    1994-01-01

    Studies in the field of so-called 'Precise Neutron Optics' at JAERI were reported, since the beginning of 1970. It started with the photographic detection of the 'Pendellusung Fringes' in a wedge-shaped Si crystal, promoted by Prof.K.Kohra. Neutron diffraction topography was also tried and used for the 'direct' observation of the substructure in a Cu-5%Ge single crystal, carried out by the present author. So-called 'VSANS' (Very Small Angle Neutron Scattering) was also tried, with the angular resolution better than 0.1 sec. of arc, for the structural observation of several kinds of 'amorphous' materials, such as neutron-irradiated silica glasses, Pb-containing glasses and several ribbon-shaped amorphous alloys, carried out by Dr.K.Doi. Recently with the co-operation with Prof.S.Kikuta's group, some interferometric experiments were tried, such as the detection of the double-refraction phenomenon of the neutron in the magnetic materials, carried out by Dr.S.Nakatani. The apparatus for precise neutron optics and topography (PNO) was constructed at the JRR-3M in JAERI in 1992, which was just properly made for the studies in the present thema. With the PNO, the characterization of Ni-Ti multilayer mirror for the interferometer with the cold/ ultra-cold neutrons was carried out, the results being reported in the other article of this symposium by Dr.H.Funahashi. Through the test use of the PNO with the neutron interferometry, carried out by Dr.Y.Hasegawa, it was revealed that the PNO is the best facility in the world for the neutron interferometry; with the datas of the count ratio upto 20 cps and the contrast more than 40%. Dr.K.Aizawa is now refining the VSANS-technique on the PNO, for the precise observation of the precipitation behaviour of high density small particles such as metatic alloy-system. (author)

  5. Precision of working memory for speech sounds.

    Science.gov (United States)

    Joseph, Sabine; Iverson, Paul; Manohar, Sanjay; Fox, Zoe; Scott, Sophie K; Husain, Masud

    2015-01-01

    Memory for speech sounds is a key component of models of verbal working memory (WM). But how good is verbal WM? Most investigations assess this using binary report measures to derive a fixed number of items that can be stored. However, recent findings in visual WM have challenged such "quantized" views by employing measures of recall precision with an analogue response scale. WM for speech sounds might rely on both continuous and categorical storage mechanisms. Using a novel speech matching paradigm, we measured WM recall precision for phonemes. Vowel qualities were sampled from a formant space continuum. A probe vowel had to be adjusted to match the vowel quality of a target on a continuous, analogue response scale. Crucially, this provided an index of the variability of a memory representation around its true value and thus allowed us to estimate how memories were distorted from the original sounds. Memory load affected the quality of speech sound recall in two ways. First, there was a gradual decline in recall precision with increasing number of items, consistent with the view that WM representations of speech sounds become noisier with an increase in the number of items held in memory, just as for vision. Based on multidimensional scaling (MDS), the level of noise appeared to be reflected in distortions of the formant space. Second, as memory load increased, there was evidence of greater clustering of participants' responses around particular vowels. A mixture model captured both continuous and categorical responses, demonstrating a shift from continuous to categorical memory with increasing WM load. This suggests that direct acoustic storage can be used for single items, but when more items must be stored, categorical representations must be used.

  6. Precise object tracking under deformation

    International Nuclear Information System (INIS)

    Saad, M.H

    2010-01-01

    The precise object tracking is an essential issue in several serious applications such as; robot vision, automated surveillance (civil and military), inspection, biomedical image analysis, video coding, motion segmentation, human-machine interface, visualization, medical imaging, traffic systems, satellite imaging etc. This frame-work focuses on the precise object tracking under deformation such as scaling , rotation, noise, blurring and change of illumination. This research is a trail to solve these serious problems in visual object tracking by which the quality of the overall system will be improved. Developing a three dimensional (3D) geometrical model to determine the current pose of an object and predict its future location based on FIR model learned by the OLS. This framework presents a robust ranging technique to track a visual target instead of the traditional expensive ranging sensors. The presented research work is applied to real video stream and achieved high precession results.

  7. Precision electroweak physics at LEP

    Energy Technology Data Exchange (ETDEWEB)

    Mannelli, M.

    1994-12-01

    Copious event statistics, a precise understanding of the LEP energy scale, and a favorable experimental situation at the Z{sup 0} resonance have allowed the LEP experiments to provide both dramatic confirmation of the Standard Model of strong and electroweak interactions and to place substantially improved constraints on the parameters of the model. The author concentrates on those measurements relevant to the electroweak sector. It will be seen that the precision of these measurements probes sensitively the structure of the Standard Model at the one-loop level, where the calculation of the observables measured at LEP is affected by the value chosen for the top quark mass. One finds that the LEP measurements are consistent with the Standard Model, but only if the mass of the top quark is measured to be within a restricted range of about 20 GeV.

  8. Structurally uniform and atomically precise carbon nanostructures

    Science.gov (United States)

    Segawa, Yasutomo; Ito, Hideto; Itami, Kenichiro

    2016-01-01

    Nanometre-sized carbon materials consisting of benzene units oriented in unique geometric patterns, hereafter named nanocarbons, conduct electricity, absorb and emit light, and exhibit interesting magnetic properties. Spherical fullerene C60, cylindrical carbon nanotubes and sheet-like graphene are representative forms of nanocarbons, and theoretical simulations have predicted several exotic 3D nanocarbon structures. At present, synthetic routes to nanocarbons mainly lead to mixtures of molecules with a range of different structures and properties, which cannot be easily separated or refined into pure forms. Some researchers believe that it is impossible to synthesize these materials in a precise manner. Obtaining ‘pure’ nanocarbons is a great challenge in the field of nanocarbon science, and the construction of structurally uniform nanocarbons, ideally as single molecules, is crucial for the development of functional materials in nanotechnology, electronics, optics and biomedical applications. This Review highlights the organic chemistry approach — more specifically, bottom-up construction with atomic precision — that is currently the most promising strategy towards this end.

  9. Precise Object Tracking under Deformation

    International Nuclear Information System (INIS)

    Saad, M.H.

    2010-01-01

    The precise object tracking is an essential issue in several serious applications such as; robot vision, automated surveillance (civil and military), inspection, biomedical image analysis, video coding, motion segmentation, human-machine interface, visualization, medical imaging, traffic systems, satellite imaging etc. This framework focuses on the precise object tracking under deformation such as scaling, rotation, noise, blurring and change of illumination. This research is a trail to solve these serious problems in visual object tracking by which the quality of the overall system will be improved. Developing a three dimensional (3D) geometrical model to determine the current pose of an object and predict its future location based on FIR model learned by the OLS. This framework presents a robust ranging technique to track a visual target instead of the traditional expensive ranging sensors. The presented research work is applied to real video stream and achieved high precession results. xiiiThe precise object tracking is an essential issue in several serious applications such as; robot vision, automated surveillance (civil and military), inspection, biomedical image analysis, video coding, motion segmentation, human-machine interface, visualization, medical imaging, traffic systems, satellite imaging etc. This framework focuses on the precise object tracking under deformation such as scaling, rotation, noise, blurring and change of illumination. This research is a trail to solve these serious problems in visual object tracking by which the quality of the overall system will be improved. Developing a three dimensional (3D) geometrical model to determine the current pose of an object and predict its future location based on FIR model learned by the OLS. This framework presents a robust ranging technique to track a visual target instead of the traditional expensive ranging sensors. The presented research work is applied to real video stream and achieved high

  10. Precision Strike Annual Programs Review

    Science.gov (United States)

    2009-03-11

    Damage Area*• GPS / INS Navigation + SAL Terminal • Precise əm CEP • Low Probability of Collateral Damage • GPS Extends Glide Range to 10+km • Agile...Page 311 Mar 09 Unclassified Unclassified Viper Strike Lineage Viper Strike SAL Seeker Proof of Principle Demos I & II Hunter-Viper Strike Quick...Information Management • CCA - Clinger Cohen Act • RIT- Rapid Improvement Team • BMMP – Business Management Modernization Program • BTA/ERAM – Business

  11. Precision titration mini-calorimeter

    International Nuclear Information System (INIS)

    Ensor, D.; Kullberg, L.; Choppin, G.

    1977-01-01

    The design and test of a small volume calorimeter of high precision and simple design is described. The calorimeter operates with solution sample volumes in the range of 3 to 5 ml. The results of experiments on the entropy changes for two standard reactions: (1) reaction of tris(hydroxymethyl)aminomethane with hydrochloric acid and (2) reaction between mercury(II) and bromide ions are reported to confirm the accuracy and overall performance of the calorimeter

  12. Higgs Precision Measurements with ATLAS

    CERN Document Server

    Boumediene, Djamel Eddine; The ATLAS collaboration

    2017-01-01

    After the discovery of the Higgs boson, precise measurements of its properties are of particular importance to understand the true nature of the found particle, which could be the Standard Model predicted Higgs, or indeed offering to be a portal for new physics beyond the Standard Model. In this talk measurement of the mass, cross sections and the couplings of the Higgs boson in bosonic and fermionic decay channels with the ATLAS detector will be presented and compared with Standard Model predictions.

  13. Numerical precision and data structures

    Science.gov (United States)

    Schenk, W.

    1978-01-01

    Technical proposals and recommendations for revising FORTRAN were studied and categorized. In the area of numerical precision, the proposals basically agree on a set of necessary parameters, although a wide range of nomenclature and specific function names are used. Environmental parameters identified include the following: (1) base of floating point representation, (2) largest positive real number, exponent and integer, (3) largest negative real number, exponent and integer, (4) number of significant digits, and (5) exponent bias.

  14. LYSO based precision timing calorimeters

    Science.gov (United States)

    Bornheim, A.; Apresyan, A.; Ronzhin, A.; Xie, S.; Duarte, J.; Spiropulu, M.; Trevor, J.; Anderson, D.; Pena, C.; Hassanshahi, M. H.

    2017-11-01

    In this report we outline the study of the development of calorimeter detectors using bright scintillating crystals. We discuss how timing information with a precision of a few tens of pico seconds and below can significantly improve the reconstruction of the physics events under challenging high pileup conditions to be faced at the High-Luminosity LHC or a future hadron collider. The particular challenge in measuring the time of arrival of a high energy photon lies in the stochastic component of the distance of initial conversion and the size of the electromagnetic shower. We present studies and measurements from test beams for calorimeter based timing measurements to explore the ultimate timing precision achievable for high energy photons of 10 GeV and above. We focus on techniques to measure the timing with a high precision in association with the energy of the photon. We present test-beam studies and results on the timing performance and characterization of the time resolution of LYSO-based calorimeters. We demonstrate time resolution of 30 ps is achievable for a particular design.

  15. Knowledge of Precision Farming Beneficiaries

    Directory of Open Access Journals (Sweden)

    A.V. Greena

    2016-05-01

    Full Text Available Precision Farming is one of the many advanced farming practices that make production more efficient by better resource management and reducing wastage. TN-IAMWARM is a world bank funded project aims to improve the farm productivity and income through better water management. The present study was carried out in Kambainallur sub basin of Dharmapuri district with 120 TN-IAMWARM beneficiaries as respondents. The result indicated that more than three fourth (76.67 % of the respondents had high level of knowledge on precision farming technologies which was made possible by the implementation of TN-IAMWARM project. The study further revealed that educational status, occupational status and exposure to agricultural messages had a positive and significant contribution to the knowledge level of the respondents at 0.01 level of probability whereas experience in precision farming and social participation had a positive and significant contribution at 0.05 level of probability.

  16. Stabilization and real world satellite problem. [transformations for stabilizing orbital equations

    Science.gov (United States)

    Velez, C. E.

    1975-01-01

    The use of transformations of orbital equations has been considered in connection with requirements for more accurate data. The reported investigation is concerned with an evaluation of the relative merits of such transformations. The formulations tested include the classical Cowell formulation, the time regularized formulation, stabilization by the use of integrals, and stabilization by the use of elements. It is found that irrespective of efficiency considerations, stabilizing transformation makes it possible to obtain precisions which are unattainable with the Cowell formulations.

  17. The precision of the NDVI derived from AVHRR observations

    International Nuclear Information System (INIS)

    Roderick, M.; Smith, R.; Cridland, S.

    1996-01-01

    Vegetation studies using NOAA-AVHRR data have tended to focus on the use of the normalized difference vegetation index (NDVI). This unitless index is computed using near-infrared and red reflectances, and thus has both an accuracy and precision. This article reports on a formal statistical framework for assessing the precision of the NDVI derived from NOAA-AVHRR observations. The framework is based on the “best possible” precision concept, which assumes that signal quantization is the only source of observational error. While the radiance resolution of a spectral observation is essentially fixed by the instrument characteristics, the reflectance resolution is the radiance resolution divided by the cosine of the solar zenith angle. Using typical solar zenith angles for AVHRR image acquisitions over Australia, ± 0.01 NDVI units is typically with “best possible” precision attainable in the NDVI, although this degrades significantly over dark targets, and at large solar zenith angles. Transforming the computed NDVI into a single byte for disk storage results in little or no loss of precision. The framework developed in this article can be adapted to estimate the “best possible” precision of other vegetation indices derived using data from other remote sensing satellites. (author)

  18. Precision luminosity measurement at ILC

    CERN Document Server

    AUTHOR|(CDS)2073074; Pandurovic, M; Smiljanic, I

    2013-01-01

    In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can be reduced to the permille level independently of a precision with which the beam parameters are known. Specific event selection combined with the corrective methods we introduce, leads to the systematic uncertainty from the beam-induced effects to be at a few permille level in the peak region above the 80% of the nominal centre-of-mass energies at ILC.

  19. Electroweak precision measurements in CMS

    CERN Document Server

    Dordevic, Milos

    2017-01-01

    An overview of recent results on electroweak precision measurements from the CMS Collaboration is presented. Studies of the weak boson differential transverse momentum spectra, Z boson angular coefficients, forward-backward asymmetry of Drell-Yan lepton pairs and charge asymmetry of W boson production are made in comparison to the state-of-the-art Monte Carlo generators and theoretical predictions. The results show a good agreement with the Standard Model. As a proof of principle for future W mass measurements, a W-like analysis of the Z boson mass is performed.

  20. Research on the precision measurement of super-low reflectivity

    Science.gov (United States)

    Yuan, Hao-yu; Lu, Zong-gui; Xia, Yan-wen; Peng, Zhi-tao; Liu, Hua; Xu, Long-bo; Sun, Zhi-hong; Tang, Jun

    2010-10-01

    Introduced a high-precision measurement of measured the super-low reflectivity and small sampling angle. Using single reflect way measured, and compare with re-swatch. Testing the reflectance of the sampling mirror which be used on TIL, and analyze the error. Research results indicate, the main factor which affect result is energy detector error and energy detector linearity. This methods is easy and have high-precision, it can be used to measure the super-low reflectivity sampling mirror reflectance.

  1. Laser precision microfabrication in Japan

    Science.gov (United States)

    Miyamoto, Isamu; Ooie, Toshihiko; Takeno, Shozui

    2000-11-01

    Electronic devices such as handy phones and micro computers have been rapidly expanding their market recent years due to their enhanced performance, down sizing and cost down. This has been realized by the innovation in the precision micro- fabrication technology of semiconductors and printed wiring circuit boards (PWB) where laser technologies such as lithography, drilling, trimming, welding and soldering play an important role. In phot lithography, for instance, KrF excimer lasers having a resolution of 0.18 micrometers has been used in production instead of mercury lamp. Laser drilling of PWB has been increased up to over 1000 holes per second, and approximately 800 laser drilling systems of PWB are expected to be delivered in the world market this year, and most of these laser processing systems are manufactured in Japan. Trend of laser micro-fabrication in Japanese industry is described along with recent topics of R&D, government supported project and future tasks of industrial laser precision micro-fabrication on the basis of the survey conducted by Japan laser Processing Society.

  2. Laser fusion and precision engineering

    International Nuclear Information System (INIS)

    Nakai, Sadao

    1989-01-01

    The development of laser nuclear fusion energy for attaining the self supply of energy in Japan and establishing the future perspective as the nation is based in the wide fields of high level science and technology. Therefore to its promotion, large expectation is placed as the powerful traction for the development of creative science and technology which are particularly necessary in Japan. The research on laser nuclear fusion advances steadily in the elucidation of the physics of pellet implosion which is its basic concept and compressed plasma parameters. In September, 1986, the number of neutron generation 10 13 , and in October, 1988, the high density compression 600 times as high as solid density have been achieved. Based on these results, now the laser nuclear fusion is in the situation to begin the attainment of ignition condition for nuclear fusion and the realization of break even. The optical components, high power laser technology, fuel pellet production, high resolution measurement, the simulation of implosion using a supercomputer and so on are closely related to precision engineering. In this report, the mechanism of laser nuclear fusion, the present status of its research, and the basic technologies and precision engineering are described. (K.I.)

  3. Memory improves precision of cell sensing in fluctuating environments

    Science.gov (United States)

    Aquino, Gerardo; Tweedy, Luke; Heinrich, Doris; Endres, Robert G.

    2014-07-01

    Biological cells are often found to sense their chemical environment near the single-molecule detection limit. Surprisingly, this precision is higher than simple estimates of the fundamental physical limit, hinting towards active sensing strategies. In this work, we analyse the effect of cell memory, e.g. from slow biochemical processes, on the precision of sensing by cell-surface receptors. We derive analytical formulas, which show that memory significantly improves sensing in weakly fluctuating environments. However, surprisingly when memory is adjusted dynamically, the precision is always improved, even in strongly fluctuating environments. In support of this prediction we quantify the directional biases in chemotactic Dictyostelium discoideum cells in a flow chamber with alternating chemical gradients. The strong similarities between cell sensing and control engineering suggest universal problem-solving strategies of living matter.

  4. Precision Electrospray Thruster Assembly (PETA) Project

    Data.gov (United States)

    National Aeronautics and Space Administration — New low cost, low volume, low power, rugged electrospray thrusters will be ideal as actuators for precision thrusting, if provided with precision high voltage power...

  5. Precision Electrospray Thruster Assembly (PETA), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — New low cost, low volume, low power, rugged electrospray thrusters will be ideal as actuators for precision thrusting, if provided with precision high voltage power...

  6. Precise measurement of dead time

    International Nuclear Information System (INIS)

    Schoenfeld, E.; Janssen, H.

    1994-01-01

    Four methods are discussed by which dead times of the non-extending type can be determined experimentally. Two methods using statistical pulses were improved by eliminating uncertainties due to counting statistics. However, it was concluded from a comparison of the four methods that those using periodical pulses are not only less time-consuming but are preferable if high-precision values are aimed at. A dead-time unit with quartz oscillator-based dead times of the non-extending type was tested using all of the four methods. Measurements within a period of three years indicated that the unit investigated here has subnanosecond stability for each of the adjusted dead-time values. (orig.)

  7. Precision cosmology and the landscape

    Energy Technology Data Exchange (ETDEWEB)

    Bousso, Raphael; Bousso, Raphael

    2006-10-01

    After reviewing the cosmological constant problem -- why is Lambda not huge? -- I outline the two basic approaches that had emerged by the late 1980s, and note that each made a clear prediction. Precision cosmological experiments now indicate that the cosmological constant is nonzero. This result strongly favors the environmental approach, in which vacuum energy can vary discretely among widely separated regions in the universe. The need to explain this variation from first principles constitutes an observational constraint on fundamental theory. I review arguments that string theory satisfies this constraint, as it contains a dense discretuum of metastable vacua. The enormous landscape of vacua calls for novel, statistical methods of deriving predictions, and it prompts us to reexamine our description of spacetime on the largest scales. I discuss the effects of cosmological dynamics, and I speculate that weighting vacua by their entropy production may allow for prior-free predictions that do not resort to explicitly anthropic arguments.

  8. GPS Precision Timing at CERN

    CERN Document Server

    Beetham, C G

    1999-01-01

    For the past decade, the Global Positioning System (GPS) has been used to provide precise time, frequency and position co-ordinates world-wide. Recently, equipment has become available specialising in providing extremely accurate timing information, referenced to Universal Time Co-ordinates (UTC). This feature has been used at CERN to provide time of day information for systems that have been installed in the Proton Synchrotron (PS), Super Proton Synchrotron (SPS) and the Large Electron Positron (LEP) machines. The different systems are described as well as the planned developments, particularly with respect to optical transmission and the Inter-Range Instrumentation Group IRIG-B standard, for future use in the Large Hadron Collider (LHC).

  9. Precise Analysis of String Expressions

    DEFF Research Database (Denmark)

    Christensen, Aske Simon; Møller, Anders; Schwartzbach, Michael Ignatieff

    2003-01-01

    , including statically checking the syntax of dynamically generated expressions, such as SQL queries. Our analysis constructs flow graphs from class files and generates a context-free grammar with a nonterminal for each string expression. The language of this grammar is then widened into a regular language......We perform static analysis of Java programs to answer a simple question: which values may occur as results of string expressions? The answers are summarized for each expression by a regular language that is guaranteed to contain all possible values. We present several applications of this analysis...... are automatically produced. We present extensive benchmarks demonstrating that the analysis is efficient and produces results of useful precision....

  10. Ultrasonic precision optical grinding technology

    Science.gov (United States)

    Cahill, Michael J.; Bechtold, Michael J.; Fess, Edward; Wolfs, Frank L.; Bechtold, Rob

    2015-10-01

    As optical geometries become more precise and complex and a wider range of materials are used, the processes used for manufacturing become more critical. As the preparatory stage for polishing, this is especially true for grinding. Slow processing speeds, accelerated tool wear, and poor surface quality are often detriments in manufacturing glass and hard ceramics. The quality of the ground surface greatly influences the polishing process and the resulting finished product. Through extensive research and development, OptiPro Systems has introduced an ultrasonic assisted grinding technology, OptiSonic, which has numerous advantages over traditional grinding processes. OptiSonic utilizes a custom tool holder designed to produce oscillations in line with the rotating spindle. A newly developed software package called IntelliSonic is integral to this platform. IntelliSonic automatically characterizes the tool and continuously optimizes the output frequency for optimal cutting while in contact with the part. This helps maintain a highly consistent process under changing load conditions for a more accurate surface. Utilizing a wide variety of instruments, test have proven to show a reduction in tool wear and increase in surface quality while allowing processing speeds to be increased. OptiSonic has proven to be an enabling technology to overcome the difficulties seen in grinding of glass and hard optical ceramics. OptiSonic has demonstrated numerous advantages over the standard CNC grinding process. Advantages are evident in reduced tool wear, better surface quality, and reduced cycle times due to increased feed rates. These benefits can be seen over numerous applications within the precision optics industry.

  11. Cryogenic Stepping Piezomotor for Large Torque, Precise Rotary Motion Control in Passive Optics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes novel single crystal piezomotors for large torque, high precision, and cryogenic actuation with capability of position set-hold with...

  12. Precision production: enabling deterministic throughput for precision aspheres with MRF

    Science.gov (United States)

    Maloney, Chris; Entezarian, Navid; Dumas, Paul

    2017-10-01

    Aspherical lenses offer advantages over spherical optics by improving image quality or reducing the number of elements necessary in an optical system. Aspheres are no longer being used exclusively by high-end optical systems but are now replacing spherical optics in many applications. The need for a method of production-manufacturing of precision aspheres has emerged and is part of the reason that the optics industry is shifting away from artisan-based techniques towards more deterministic methods. Not only does Magnetorheological Finishing (MRF) empower deterministic figure correction for the most demanding aspheres but it also enables deterministic and efficient throughput for series production of aspheres. The Q-flex MRF platform is designed to support batch production in a simple and user friendly manner. Thorlabs routinely utilizes the advancements of this platform and has provided results from using MRF to finish a batch of aspheres as a case study. We have developed an analysis notebook to evaluate necessary specifications for implementing quality control metrics. MRF brings confidence to optical manufacturing by ensuring high throughput for batch processing of aspheres.

  13. Precision measurements with atom interferometry

    Science.gov (United States)

    Schubert, Christian; Abend, Sven; Schlippert, Dennis; Ertmer, Wolfgang; Rasel, Ernst M.

    2017-04-01

    Interferometry with matter waves enables precise measurements of rotations, accelerations, and differential accelerations [1-5]. This is exploited for determining fundamental constants [2], in fundamental science as e.g. testing the universality of free fall [3], and is applied for gravimetry [4], and gravity gradiometry [2,5]. At the Institut für Quantenoptik in Hannover, different approaches are pursued. A large scale device is designed and currently being set up to investigate the gain in precision for gravimetry, gradiometry, and fundamental tests on large baselines [6]. For field applications, a compact and transportable device is being developed. Its key feature is an atom chip source providing a collimated high flux of atoms which is expected to mitigate systematic uncertainties [7,8]. The atom chip technology and miniaturization benefits from microgravity experiments in the drop tower in Bremen and sounding rocket experiments [8,9] which act as pathfinders for space borne operation [10]. This contribution will report about our recent results. The presented work is supported by the CRC 1227 DQ-mat, the CRC 1128 geo-Q, the RTG 1729, the QUEST-LFS, and by the German Space Agency (DLR) with funds provided by the Federal Ministry of Economic Affairs and Energy (BMWi) due to an enactment of the German Bundestag under Grant No. DLR 50WM1552-1557. [1] P. Berg et al., Phys. Rev. Lett., 114, 063002, 2015; I. Dutta et al., Phys. Rev. Lett., 116, 183003, 2016. [2] J. B. Fixler et al., Science 315, 74 (2007); G. Rosi et al., Nature 510, 518, 2014. [3] D. Schlippert et al., Phys. Rev. Lett., 112, 203002, 2014. [4] A. Peters et al., Nature 400, 849, 1999; A. Louchet-Chauvet et al., New J. Phys. 13, 065026, 2011; C. Freier et al., J. of Phys.: Conf. Series 723, 012050, 2016. [5] J. M. McGuirk et al., Phys. Rev. A 65, 033608, 2002; P. Asenbaum et al., arXiv:1610.03832. [6] J. Hartwig et al., New J. Phys. 17, 035011, 2015. [7] H. Ahlers et al., Phys. Rev. Lett. 116, 173601

  14. Visual photometry: accuracy and precision

    Science.gov (United States)

    Whiting, Alan

    2018-01-01

    Visual photometry, estimation by eye of the brightness of stars, remains an important source of data even in the age of widespread precision instruments. However, the eye-brain system differs from electronic detectors and its results may be expected to differ in several respects. I examine a selection of well-observed variables from the AAVSO database to determine several internal characteristics of this data set. Visual estimates scatter around the fitted curves with a standard deviation of 0.14 to 0.34 magnitudes, most clustered in the 0.21-0.25 range. The variation of the scatter does not seem to correlate with color, type of variable, or depth or speed of variation of the star’s brightness. The scatter of an individual observer’s observations changes from star to star, in step with the overall scatter. The shape of the deviations from the fitted curve is non-Gaussian, with positive excess kurtosis (more outlying observations). These results have implications for use of visual data, as well as other citizen science efforts.

  15. PRECISION TIME-DELAY GENERATOR

    Science.gov (United States)

    Carr, B.J.; Peckham, V.D.

    1959-06-16

    A precision time-delay generator circuit with low jitter is described. The first thyratron has a series resonant circuit and a diode which is connected to the second thyratron. The first thyratron is triggered at the begin-ning of a time delay and a capacitor is discharged through the first thyratron and the diode, thereby, triggering the second thyratron. (T.R.H.) l6l9O The instrument described can measure pressures between sea level and 300,000 ft. The pressure- sensing transducer of the instrument is a small cylindrical tube with a thin foil of titanium-tritium fastened around the inside of the tube. Output is a digital signal which can be used for storage or telemetering more conveniently than an analog signal. (W.D.M.) l6l9l An experimental study was made on rolling contacts in the temperature range of 550 to 1000 deg F. Variables such as material composition, hardness, and operating conditions were investigated in a rolling test stand. Ball bearing tests were run to determine the effect of design parameters, bearing materials, lubricants, and operating conditions. (auth)

  16. The Age of Precision Cosmology

    Science.gov (United States)

    Chuss, David T.

    2012-01-01

    In the past two decades, our understanding of the evolution and fate of the universe has increased dramatically. This "Age of Precision Cosmology" has been ushered in by measurements that have both elucidated the details of the Big Bang cosmology and set the direction for future lines of inquiry. Our universe appears to consist of 5% baryonic matter; 23% of the universe's energy content is dark matter which is responsible for the observed structure in the universe; and 72% of the energy density is so-called "dark energy" that is currently accelerating the expansion of the universe. In addition, our universe has been measured to be geometrically flat to 1 %. These observations and related details of the Big Bang paradigm have hinted that the universe underwent an epoch of accelerated expansion known as Uinflation" early in its history. In this talk, I will review the highlights of modern cosmology, focusing on the contributions made by measurements of the cosmic microwave background, the faint afterglow of the Big Bang. I will also describe new instruments designed to measure the polarization of the cosmic microwave background in order to search for evidence of cosmic inflation.

  17. Studying antimatter with laser precision

    CERN Multimedia

    Katarina Anthony

    2012-01-01

    The next generation of antihydrogen trapping devices, ALPHA-2, is moving into CERN’s Antiproton Decelerator (AD) hall. This brand-new experiment will allow the ALPHA collaboration to conduct studies of antimatter with greater precision. ALPHA spokesperson Jeffrey Hangst was recently awarded a grant by the Carlsberg Foundation, which will be used to purchase equipment for the new experiment.   A 3-D view of the new magnet (in blue) and cryostat. The red lines show the paths of laser beams. LHC-type current leads for the superconducting magnets are visible on the top-right of the image. The ALPHA collaboration has been working to trap and study antihydrogen since 2006. Using antiprotons provided by CERN’s Antiproton Decelerator (AD), ALPHA was the first experiment to trap antihydrogen and to hold it long enough to study its properties. “The new ALPHA-2 experiment will use integrated lasers to probe the trapped antihydrogen,” explains Jeffrey Hangst, ALP...

  18. Precision is in their nature

    CERN Multimedia

    Antonella Del Rosso

    2014-01-01

    There are more than 100 of them in the LHC ring and they have a total of about 400 degrees of freedom. Each one has 4 motors and the newest ones have their own beam-monitoring pickups. Their jaws constrain the relativistic, high-energy particles to a very small transverse area and protect the machine aperture. We are speaking about the LHC collimators, those ultra-precise instruments that leave escaping unstable particles no chance.   The internal structure of a new LHC collimator featuring (see red arrow) one of the beam position monitor's pickups. Designed at CERN but mostly produced by very specialised manufacturers in Europe, the LHC collimators are among the most complex elements of the accelerator. Their job is to control and safely dispose of the halo particles that are produced by unavoidable beam losses from the circulating beam core. “The LHC collimation system has been designed to ensure that beam losses in superconducting magnets remain below quench limits in al...

  19. High precision redundant robotic manipulator

    International Nuclear Information System (INIS)

    Young, K.K.D.

    1998-01-01

    A high precision redundant robotic manipulator for overcoming contents imposed by obstacles or imposed by a highly congested work space is disclosed. One embodiment of the manipulator has four degrees of freedom and another embodiment has seven degrees of freedom. Each of the embodiments utilize a first selective compliant assembly robot arm (SCARA) configuration to provide high stiffness in the vertical plane, a second SCARA configuration to provide high stiffness in the horizontal plane. The seven degree of freedom embodiment also utilizes kinematic redundancy to provide the capability of avoiding obstacles that lie between the base of the manipulator and the end effector or link of the manipulator. These additional three degrees of freedom are added at the wrist link of the manipulator to provide pitch, yaw and roll. The seven degrees of freedom embodiment uses one revolute point per degree of freedom. For each of the revolute joints, a harmonic gear coupled to an electric motor is introduced, and together with properly designed based servo controllers provide an end point repeatability of less than 10 microns. 3 figs

  20. Personalized and precision orthodontic therapy.

    Science.gov (United States)

    Iwasaki, L R; Covell, D A; Frazier-Bowers, S A; Kapila, S; Huja, S S; Nickel, J C

    2015-04-01

    To bring together orthodontic stakeholders from academics, industry, and private practice for a series of thematically focused workshops to explore and develop the transfer of novel approaches into clinical orthodontic practice. Twenty-seven invited speakers, eight poster presenters, and participants of the Consortium for Orthodontic Advances in Science and Technology (COAST) 2014 Innovators' Workshop at the Eaglewood Resort and Spa, Itasca, Illinois, September 11-14, 2014. Five themed sessions involving between 4-7 presentations followed by panel discussions were organized. The aims of the discussion sessions were to highlight important findings and consider the strength of evidence for these, indicate next steps and needed research or technological developments to move forward, and to weigh the expected benefits from these findings and steps to implement in clinical practice. Among important areas for attention identified were need for multiscale and multispecies modeling and experimentation for interspecies translation of results; large-scale collaborative efforts within the profession to address the need for adequate sample sizes for future genetic studies of complex traits such as malocclusion; a consortium approach to improve new technologies such as intra-oral scanning and 3D imaging by establishing standards; and harnessing the growing body of knowledge about bone biology for application in orthodontics. With increased awareness of the potential of current and emerging technologies, translation of personalized and precision approaches in the field of orthodontics holds ever-increasing promise. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Accelerating scientific computations with mixed precision algorithms

    Science.gov (United States)

    Baboulin, Marc; Buttari, Alfredo; Dongarra, Jack; Kurzak, Jakub; Langou, Julie; Langou, Julien; Luszczek, Piotr; Tomov, Stanimire

    2009-12-01

    On modern architectures, the performance of 32-bit operations is often at least twice as fast as the performance of 64-bit operations. By using a combination of 32-bit and 64-bit floating point arithmetic, the performance of many dense and sparse linear algebra algorithms can be significantly enhanced while maintaining the 64-bit accuracy of the resulting solution. The approach presented here can apply not only to conventional processors but also to other technologies such as Field Programmable Gate Arrays (FPGA), Graphical Processing Units (GPU), and the STI Cell BE processor. Results on modern processor architectures and the STI Cell BE are presented. Program summaryProgram title: ITER-REF Catalogue identifier: AECO_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AECO_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 7211 No. of bytes in distributed program, including test data, etc.: 41 862 Distribution format: tar.gz Programming language: FORTRAN 77 Computer: desktop, server Operating system: Unix/Linux RAM: 512 Mbytes Classification: 4.8 External routines: BLAS (optional) Nature of problem: On modern architectures, the performance of 32-bit operations is often at least twice as fast as the performance of 64-bit operations. By using a combination of 32-bit and 64-bit floating point arithmetic, the performance of many dense and sparse linear algebra algorithms can be significantly enhanced while maintaining the 64-bit accuracy of the resulting solution. Solution method: Mixed precision algorithms stem from the observation that, in many cases, a single precision solution of a problem can be refined to the point where double precision accuracy is achieved. A common approach to the solution of linear systems, either dense or sparse, is to perform the LU

  2. Precision laser spectroscopy of highly charged ions

    International Nuclear Information System (INIS)

    Kuehl, T.; Borneis, S.; Becker, S.; Dax, A.; Engel, T.; Grieser, R.; Huber, G.; Klaft, I.; Klepper, O.; Kohl, A.; Marx, D.; Meier, K.; Neumann, R.; Schmitt, F.; Seelig, P.; Voelker, L.

    1996-01-01

    Recently, intense beams of highly charged ions have become available at heavy ion cooler rings. The obstacle for producing these highly interesting candidates is the large binding energy of K-shell electrons in heavy systems in excess of 100 keV. One way to remove these electrons is to strip them off by passing the ion through material. In the cooler ring, the ions are cooled to a well defined velocity. At the SIS/ESR complex it is possible to produce, store, and cool highly charged ions up to bare uranium with intensities exceeding 10 8 atoms in the ring. This opens the door for precision laser spectroscopy of hydrogenlike-heavy ions, e.g. 209 Bi 82+ , and allows to examine the interaction of the single electron with the large fields of the heavy nucleus, exceeding any artificially produced electric and magnetic fields by orders of magnitude. In the electron cooler the interaction of electrons and highly charged ions otherwise only present in the hottest plasmas can be studied. (orig.)

  3. Precise GNSS Positioning Using Smart Devices

    Directory of Open Access Journals (Sweden)

    Eugenio Realini

    2017-10-01

    Full Text Available The recent access to GNSS (Global Navigation Satellite System phase observations on smart devices, enabled by Google through its Android operating system, opens the possibility to apply precise positioning techniques using off-the-shelf, mass-market devices. The target of this work is to evaluate whether this is feasible, and which positioning accuracy can be achieved by relative positioning of the smart device with respect to a base station. Positioning of a Google/HTC Nexus 9 tablet was performed by means of batch least-squares adjustment of L1 phase double-differenced observations, using the open source goGPS software, over baselines ranging from approximately 10 m to 8 km, with respect to both physical (geodetic or low-cost and virtual base stations. The same positioning procedure was applied also to a co-located u-blox low-cost receiver, to compare the performance between the receiver and antenna embedded in the Nexus 9 and a standard low-cost single-frequency receiver with external patch antenna. The results demonstrate that with a smart device providing raw GNSS phase observations, like the Nexus 9, it is possible to reach decimeter-level accuracy through rapid-static surveys, without phase ambiguity resolution. It is expected that sub-centimeter accuracy could be achieved, as demonstrated for the u-blox case, if integer phase ambiguities were correctly resolved.

  4. Precise GNSS Positioning Using Smart Devices.

    Science.gov (United States)

    Realini, Eugenio; Caldera, Stefano; Pertusini, Lisa; Sampietro, Daniele

    2017-10-24

    The recent access to GNSS (Global Navigation Satellite System) phase observations on smart devices, enabled by Google through its Android operating system, opens the possibility to apply precise positioning techniques using off-the-shelf, mass-market devices. The target of this work is to evaluate whether this is feasible, and which positioning accuracy can be achieved by relative positioning of the smart device with respect to a base station. Positioning of a Google/HTC Nexus 9 tablet was performed by means of batch least-squares adjustment of L1 phase double-differenced observations, using the open source goGPS software, over baselines ranging from approximately 10 m to 8 km, with respect to both physical (geodetic or low-cost) and virtual base stations. The same positioning procedure was applied also to a co-located u-blox low-cost receiver, to compare the performance between the receiver and antenna embedded in the Nexus 9 and a standard low-cost single-frequency receiver with external patch antenna. The results demonstrate that with a smart device providing raw GNSS phase observations, like the Nexus 9, it is possible to reach decimeter-level accuracy through rapid-static surveys, without phase ambiguity resolution. It is expected that sub-centimeter accuracy could be achieved, as demonstrated for the u-blox case, if integer phase ambiguities were correctly resolved.

  5. An LCD tachistoscope with submillisecond precision.

    Science.gov (United States)

    Sperdin, Holger F; Repnow, Marc; Herzog, Michael H; Landis, Theodor

    2013-12-01

    Tachistoscopes allow brief visual stimulation delivery, which is crucial for experiments in which subliminal presentation is required. Up to now, tachistoscopes have had shortcomings with respect to timing accuracy, reliability, and flexibility of use. Here, we present a new and inexpensive two-channel tachistoscope that allows for exposure durations in the submillisecond range with an extremely high timing accuracy. The tachistoscope consists of two standard liquid-crystal display (LCD) monitors of the light-emitting diode (LED) backlight type, a semipermeable mirror, a mounting rack, and an experimental personal computer (PC). The monitors have been modified to provide external access to the LED backlights, which are controlled by the PC via the standard parallel port. Photodiode measurements confirmed reliable operation of the tachistoscope and revealed switching times of 3 μs. Our method may also be of great advantage in single-monitor setups, in which it allows for manipulating the stimulus timing with submillisecond precision in many experimental situations. Where this is not applicable, the monitor can be operated in standard mode by disabling the external backlight control instantaneously.

  6. Precision magnetic suspension linear bearing

    Science.gov (United States)

    Trumper, David L.; Queen, Michael A.

    1992-01-01

    We have shown the design and analyzed the electromechanics of a linear motor suitable for independently controlling two suspension degrees of freedom. This motor, at least on paper, meets the requirements for driving an X-Y stage of 10 Kg mass with about 4 m/sq sec acceleration, with travel of several hundred millimeters in X and Y, and with reasonable power dissipation. A conceptual design for such a stage is presented. The theoretical feasibility of linear and planar bearings using single or multiple magnetic suspension linear motors is demonstrated.

  7. Precision corrections and supersymmetric unification

    Science.gov (United States)

    Matchev, Konstantin Tzvetanov

    1998-07-01

    In this thesis we compute a full set of one-loop corrections to the masses and couplings in the minimal supersymmetric standard model and study their implications in various precision analyses: (1) We use the weak-scale gauge and Yukawa threshold corrections, including the non-logarithmic terms, in a complete next- to-leading order analysis of gauge and Yukawa coupling unification, both for the case of the minimal supergravity and gauge-mediated models. We then examine the effects of unification-scale threshold corrections in the minimal and missing-doublet SU(5) models. (2) We show the generic size of the one-loop mass corrections to the supersymmetric spectrum and provide a set of compact approximations which hold over the unified parameter space of the supergravity models. (3) We compute the superpartner spectrum across the entire parameter space of the gauge-mediated models, comparing it to that of the minimal supergravity model. We delineate the regions where the lightest neutralino or tau slepton is the next- to-lightest supersymmetric particle, and compute its lifetime and various branching ratios. (4) We make a classification of the tree-level mass sum rules, derive in the supergravity and gauge-mediated unification models, and study their stability against radiative corrections. (5) We calculate the leading order QCD correction to K-/overline[K] mixing within a general supersymmetric model. Using an effective field theory language, we construct /Delta S = 2 effective Lagrangians for different hierarchies of the gluino and the first two generation squark masses. For each case, we show the size of the corrections and find that they usually modify previous bounds on intergenerational squark mass mixing by more than a factor of two.

  8. High precision anatomy for MEG.

    Science.gov (United States)

    Troebinger, Luzia; López, José David; Lutti, Antoine; Bradbury, David; Bestmann, Sven; Barnes, Gareth

    2014-02-01

    Precise MEG estimates of neuronal current flow are undermined by uncertain knowledge of the head location with respect to the MEG sensors. This is either due to head movements within the scanning session or systematic errors in co-registration to anatomy. Here we show how such errors can be minimized using subject-specific head-casts produced using 3D printing technology. The casts fit the scalp of the subject internally and the inside of the MEG dewar externally, reducing within session and between session head movements. Systematic errors in matching to MRI coordinate system are also reduced through the use of MRI-visible fiducial markers placed on the same cast. Bootstrap estimates of absolute co-registration error were of the order of 1mm. Estimates of relative co-registration error were <1.5mm between sessions. We corroborated these scalp based estimates by looking at the MEG data recorded over a 6month period. We found that the between session sensor variability of the subject's evoked response was of the order of the within session noise, showing no appreciable noise due to between-session movement. Simulations suggest that the between-session sensor level amplitude SNR improved by a factor of 5 over conventional strategies. We show that at this level of coregistration accuracy there is strong evidence for anatomical models based on the individual rather than canonical anatomy; but that this advantage disappears for errors of greater than 5mm. This work paves the way for source reconstruction methods which can exploit very high SNR signals and accurate anatomical models; and also significantly increases the sensitivity of longitudinal studies with MEG. © 2013. Published by Elsevier Inc. All rights reserved.

  9. High precision anatomy for MEG☆

    Science.gov (United States)

    Troebinger, Luzia; López, José David; Lutti, Antoine; Bradbury, David; Bestmann, Sven; Barnes, Gareth

    2014-01-01

    Precise MEG estimates of neuronal current flow are undermined by uncertain knowledge of the head location with respect to the MEG sensors. This is either due to head movements within the scanning session or systematic errors in co-registration to anatomy. Here we show how such errors can be minimized using subject-specific head-casts produced using 3D printing technology. The casts fit the scalp of the subject internally and the inside of the MEG dewar externally, reducing within session and between session head movements. Systematic errors in matching to MRI coordinate system are also reduced through the use of MRI-visible fiducial markers placed on the same cast. Bootstrap estimates of absolute co-registration error were of the order of 1 mm. Estimates of relative co-registration error were < 1.5 mm between sessions. We corroborated these scalp based estimates by looking at the MEG data recorded over a 6 month period. We found that the between session sensor variability of the subject's evoked response was of the order of the within session noise, showing no appreciable noise due to between-session movement. Simulations suggest that the between-session sensor level amplitude SNR improved by a factor of 5 over conventional strategies. We show that at this level of coregistration accuracy there is strong evidence for anatomical models based on the individual rather than canonical anatomy; but that this advantage disappears for errors of greater than 5 mm. This work paves the way for source reconstruction methods which can exploit very high SNR signals and accurate anatomical models; and also significantly increases the sensitivity of longitudinal studies with MEG. PMID:23911673

  10. Modeling and control of precision actuators

    CERN Document Server

    Kiong, Tan Kok

    2013-01-01

    IntroductionGrowing Interest in Precise ActuatorsTypes of Precise ActuatorsApplications of Precise ActuatorsNonlinear Dynamics and ModelingHysteresisCreepFrictionForce RipplesIdentification and Compensation of Preisach Hysteresis in Piezoelectric ActuatorsSVD-Based Identification and Compensation of Preisach HysteresisHigh-Bandwidth Identification and Compensation of Hysteretic Dynamics in Piezoelectric ActuatorsConcluding RemarksIdentification and Compensation of Frict

  11. New methods for precision Moeller polarimetry*

    International Nuclear Information System (INIS)

    Gaskell, D.; Meekins, D.G.; Yan, C.

    2007-01-01

    Precision electron beam polarimetry is becoming increasingly important as parity violation experiments attempt to probe the frontiers of the standard model. In the few GeV regime, Moeller polarimetry is well suited to high-precision measurements, however is generally limited to use at relatively low beam currents (<10 μA). We present a novel technique that will enable precision Moeller polarimetry at very large currents, up to 100 μA. (orig.)

  12. Precision and Accuracy in PDV and VISAR

    Energy Technology Data Exchange (ETDEWEB)

    Ambrose, W. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-08-22

    recording noise precision. But from these investigations we do appreciate that the velocity-uncertainty itself has a wide distribution of values that varies with signal-amplitude modulation (is not a single value). To provide a rough rule of thumb for the velocity uncertainty, we computed the average of the relative standard deviation distributions from 60 recorded traces (with distributions of uncertainties roughly between 0.1 % to 1 % in each trace) and found a mean of the distribution of uncertainties for our experiments is not better than 0.4 % at an analysis window width of 5 ns (although for brief intervals it can be as good as 0.1 %). Further imagination and testing may be needed to reveal other possible hydrodynamics-related sources of velocity error in PDV.

  13. Deriving High-Precision Radial Velocities

    Science.gov (United States)

    Figueira, Pedro

    This chapter describes briefly the key aspects behind the derivation of precise radial velocities. I start by defining radial velocity precision in the context of astrophysics in general and exoplanet searches in particular. Next I discuss the different basic elements that constitute a spectrograph, and how these elements and overall technical choices impact on the derived radial velocity precision. Then I go on to discuss the different wavelength calibration and radial velocity calculation techniques, and how these are intimately related to the spectrograph's properties. I conclude by presenting some interesting examples of planets detected through radial velocity, and some of the new-generation instruments that will push the precision limit further.

  14. Precision injection molding of freeform optics

    Science.gov (United States)

    Fang, Fengzhou; Zhang, Nan; Zhang, Xiaodong

    2016-08-01

    Precision injection molding is the most efficient mass production technology for manufacturing plastic optics. Applications of plastic optics in field of imaging, illumination, and concentration demonstrate a variety of complex surface forms, developing from conventional plano and spherical surfaces to aspheric and freeform surfaces. It requires high optical quality with high form accuracy and lower residual stresses, which challenges both optical tool inserts machining and precision injection molding process. The present paper reviews recent progress in mold tool machining and precision injection molding, with more emphasis on precision injection molding. The challenges and future development trend are also discussed.

  15. Oligonucleotide-directed mutagenesis for precision gene editing.

    Science.gov (United States)

    Sauer, Noel J; Mozoruk, Jerry; Miller, Ryan B; Warburg, Zachary J; Walker, Keith A; Beetham, Peter R; Schöpke, Christian R; Gocal, Greg F W

    2016-02-01

    Differences in gene sequences, many of which are single nucleotide polymorphisms, underlie some of the most important traits in plants. With humanity facing significant challenges to increase global agricultural productivity, there is an urgent need to accelerate the development of these traits in plants. oligonucleotide-directed mutagenesis (ODM), one of the many tools of Cibus' Rapid Trait Development System (RTDS(™) ) technology, offers a rapid, precise and non-transgenic breeding alternative for trait improvement in agriculture to address this urgent need. This review explores the application of ODM as a precision genome editing technology, with emphasis on using oligonucleotides to make targeted edits in plasmid, episomal and chromosomal DNA of bacterial, fungal, mammalian and plant systems. The process of employing ODM by way of RTDS technology has been improved in many ways by utilizing a fluorescence conversion system wherein a blue fluorescent protein (BFP) can be changed to a green fluorescent protein (GFP) by editing a single nucleotide of the BFP gene (CAC→TAC; H66 to Y66). For example, dependent on oligonucleotide length, applying oligonucleotide-mediated technology to target the BFP transgene in Arabidopsis thaliana protoplasts resulted in up to 0.05% precisely edited GFP loci. Here, the development of traits in commercially relevant plant varieties to improve crop performance by genome editing technologies such as ODM, and by extension RTDS, is reviewed. © 2015 The Authors. Plant Biotechnology Journal published by Society for Experimental Biology and The Association of Applied Biologists and John Wiley & Sons Ltd.

  16. Bariatric Surgery and Precision Nutrition

    Directory of Open Access Journals (Sweden)

    Carolina F. Nicoletti

    2017-09-01

    Full Text Available This review provides a literature overview of new findings relating nutritional genomics and bariatric surgery. It also describes the importance of nutritional genomics concepts in personalized bariatric management. It includes a discussion of the potential role bariatric surgery plays in altering the three pillars of nutritional genomics: nutrigenetics, nutrigenomics, and epigenetics. We present studies that show the effect of each patient’s genetic and epigenetic variables on the response to surgical weight loss treatment. We include investigations that demonstrate the association of single nucleotide polymorphisms with obesity phenotypes and their influence on weight loss after bariatric surgery. We also present reports on how significant weight loss induced by bariatric surgery impacts telomere length, and we discuss studies on the existence of an epigenetic signature associated with surgery outcomes and specific gene methylation profile, which may help to predict weight loss after a surgical procedure. Finally, we show articles which evidence that bariatric surgery may affect expression of numerous genes involved in different metabolic pathways and consequently induce functional and taxonomic changes in gut microbial communities. The role nutritional genomics plays in responses to weight loss after bariatric surgery is evident. Better understanding of the molecular pathways involved in this process is necessary for successful weight management and maintenance.

  17. Bariatric Surgery and Precision Nutrition.

    Science.gov (United States)

    Nicoletti, Carolina F; Cortes-Oliveira, Cristiana; Pinhel, Marcela A S; Nonino, Carla B

    2017-09-06

    This review provides a literature overview of new findings relating nutritional genomics and bariatric surgery. It also describes the importance of nutritional genomics concepts in personalized bariatric management. It includes a discussion of the potential role bariatric surgery plays in altering the three pillars of nutritional genomics: nutrigenetics, nutrigenomics, and epigenetics. We present studies that show the effect of each patient's genetic and epigenetic variables on the response to surgical weight loss treatment. We include investigations that demonstrate the association of single nucleotide polymorphisms with obesity phenotypes and their influence on weight loss after bariatric surgery. We also present reports on how significant weight loss induced by bariatric surgery impacts telomere length, and we discuss studies on the existence of an epigenetic signature associated with surgery outcomes and specific gene methylation profile, which may help to predict weight loss after a surgical procedure. Finally, we show articles which evidence that bariatric surgery may affect expression of numerous genes involved in different metabolic pathways and consequently induce functional and taxonomic changes in gut microbial communities. The role nutritional genomics plays in responses to weight loss after bariatric surgery is evident. Better understanding of the molecular pathways involved in this process is necessary for successful weight management and maintenance.

  18. The new field of 'precision psychiatry'.

    Science.gov (United States)

    Fernandes, Brisa S; Williams, Leanne M; Steiner, Johann; Leboyer, Marion; Carvalho, André F; Berk, Michael

    2017-04-13

    Precision medicine is a new and important topic in psychiatry. Psychiatry has not yet benefited from the advanced diagnostic and therapeutic technologies that form an integral part of other clinical specialties. Thus, the vision of precision medicine as applied to psychiatry - 'precision psychiatry' - promises to be even more transformative than in other fields of medicine, which have already lessened the translational gap. Herein, we describe 'precision psychiatry' and how its several implications promise to transform the psychiatric landscape. We pay particular attention to biomarkers and to how the development of new technologies now makes their discovery possible and timely. The adoption of the term 'precision psychiatry' will help propel the field, since the current term 'precision medicine', as applied to psychiatry, is impractical and does not appropriately distinguish the field. Naming the field 'precision psychiatry' will help establish a stronger, unique identity to what promises to be the most important area in psychiatry in years to come. In summary, we provide a wide-angle lens overview of what this new field is, suggest how to propel the field forward, and provide a vision of the near future, with 'precision psychiatry' representing a paradigm shift that promises to change the landscape of how psychiatry is currently conceived.

  19. Electroweak precision data and gravitino dark matter

    Indian Academy of Sciences (India)

    Abstract. Electroweak precision measurements can provide indirect information about the possible scale of supersymmetry already at the present level of accuracy. We review present day sensitivities of precision data in mSUGRA-type models with the gravitino as the lightest supersymmetric particle (LSP). The χ2 fit is based ...

  20. Electroweak precision data and gravitino dark matter

    Indian Academy of Sciences (India)

    Electroweak precision measurements can provide indirect information about the possible scale of supersymmetry already at the present level of accuracy. We review present day sensitivities of precision data in mSUGRA-type models with the gravitino as the lightest supersymmetric particle (LSP). The 2 fit is based on , ...

  1. Visual thread quality for precision miniature mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1981-04-01

    Threaded features have eight visual appearance factors which can affect their function in precision miniature mechanisms. The Bendix practice in deburring, finishing, and accepting these conditions on miniature threads is described as is their impact in assemblies of precision miniature electromechanical assemblies.

  2. High precision laser forming for micro actuation

    NARCIS (Netherlands)

    Folkersma, Ger; Römer, Gerardus Richardus, Bernardus, Engelina; Brouwer, Dannis Michel; Huis in 't Veld, Bert; Nakata, Yoshiki; Xu, Xianfan; Roth, Stephan; Neuenschwander, Beat

    2014-01-01

    For assembly of micro-devices, such as photonic devices, the precision alignment of components is often critical for their performance. Laser forming, also known as laser-adjusting, can be used to create an integrated microactuator to align the components with sub-micron precision after bonding. In

  3. Implementing and Characterizing Precise Multiqubit Measurements

    Directory of Open Access Journals (Sweden)

    J. Z. Blumoff

    2016-09-01

    Full Text Available There are two general requirements to harness the computational power of quantum mechanics: the ability to manipulate the evolution of an isolated system and the ability to faithfully extract information from it. Quantum error correction and simulation often make a more exacting demand: the ability to perform nondestructive measurements of specific correlations within that system. We realize such measurements by employing a protocol adapted from Nigg and Girvin [Phys. Rev. Lett. 110, 243604 (2013], enabling real-time selection of arbitrary register-wide Pauli operators. Our implementation consists of a simple circuit quantum electrodynamics module of four highly coherent 3D transmon qubits, collectively coupled to a high-Q superconducting microwave cavity. As a demonstration, we enact all seven nontrivial subset-parity measurements on our three-qubit register. For each, we fully characterize the realized measurement by analyzing the detector (observable operators via quantum detector tomography and by analyzing the quantum backaction via conditioned process tomography. No single quantity completely encapsulates the performance of a measurement, and standard figures of merit have not yet emerged. Accordingly, we consider several new fidelity measures for both the detector and the complete measurement process. We measure all of these quantities and report high fidelities, indicating that we are measuring the desired quantities precisely and that the measurements are highly nondemolition. We further show that both results are improved significantly by an additional error-heralding measurement. The analyses we present here form a useful basis for the future characterization and validation of quantum measurements, anticipating the demands of emerging quantum technologies.

  4. Implementing and Characterizing Precise Multiqubit Measurements

    Science.gov (United States)

    Blumoff, J. Z.; Chou, K.; Shen, C.; Reagor, M.; Axline, C.; Brierley, R. T.; Silveri, M. P.; Wang, C.; Vlastakis, B.; Nigg, S. E.; Frunzio, L.; Devoret, M. H.; Jiang, L.; Girvin, S. M.; Schoelkopf, R. J.

    2016-07-01

    There are two general requirements to harness the computational power of quantum mechanics: the ability to manipulate the evolution of an isolated system and the ability to faithfully extract information from it. Quantum error correction and simulation often make a more exacting demand: the ability to perform nondestructive measurements of specific correlations within that system. We realize such measurements by employing a protocol adapted from Nigg and Girvin [Phys. Rev. Lett. 110, 243604 (2013)], enabling real-time selection of arbitrary register-wide Pauli operators. Our implementation consists of a simple circuit quantum electrodynamics module of four highly coherent 3D transmon qubits, collectively coupled to a high-Q superconducting microwave cavity. As a demonstration, we enact all seven nontrivial subset-parity measurements on our three-qubit register. For each, we fully characterize the realized measurement by analyzing the detector (observable operators) via quantum detector tomography and by analyzing the quantum backaction via conditioned process tomography. No single quantity completely encapsulates the performance of a measurement, and standard figures of merit have not yet emerged. Accordingly, we consider several new fidelity measures for both the detector and the complete measurement process. We measure all of these quantities and report high fidelities, indicating that we are measuring the desired quantities precisely and that the measurements are highly nondemolition. We further show that both results are improved significantly by an additional error-heralding measurement. The analyses we present here form a useful basis for the future characterization and validation of quantum measurements, anticipating the demands of emerging quantum technologies.

  5. LIGASURE (PRECISION HAEMORROIDECTOMY AT GOVT. GENERAL HOSPITAL

    Directory of Open Access Journals (Sweden)

    Anand

    2015-09-01

    Full Text Available BACKGROUND : Haemorrhoids is a common problem throughout the world. Many procedures are available for management of grade II and grade III hemorrhoids. The main postoperative complications associated with any of these procedures are pain and bleeding per rectum and pro longed healing time. Liga Surel TM haemorroidectomy was evaluated in this study for post - operative complications and symptomatic relief. METHODS: We analyzed 50 patients of hemorrhoids of grade II, III and IV who underwent Ligasure Precise haemorroidectomy by a classical Milligan - Morgan technique. The outcome factors analyzed were total operative time, blood loss, post - operative pain on visual analogue scale, any other complication and days of hospital stay. RESULTS: Of all the 50 patients, the operative ti me was less than 10 minutes in 27 patients (54% and the blood loss, as was measured by number of soaked gauze pieces only one gauze piece was soaked in 31 patients (62%. The Average Post - operative pain score measured on Visual Analogue Scale (VAS at 12, 24 & 48 hours were 6.54, 4.52 and 3.12 respectively. In all patients postoperative period and follow up was uneventful except for one patient who developed transient flatus incontinence. With physiotherapy and dietary management this problem resolved ther eafter. CONCLUSIONS: Liga Sure Hemarrhoidectomy is a safe, Technically easy and fast modality of treatment for 2 nd , 3 rd & 4 th degree of hemorrhoids whether single or multiple, requiring very less operating ti me, with no major post - operative complications an d early return to day to day activities

  6. Precision medicine for psychopharmacology: a general introduction.

    Science.gov (United States)

    Shin, Cheolmin; Han, Changsu; Pae, Chi-Un; Patkar, Ashwin A

    2016-07-01

    Precision medicine is an emerging medical model that can provide accurate diagnoses and tailored therapeutic strategies for patients based on data pertaining to genes, microbiomes, environment, family history and lifestyle. Here, we provide basic information about precision medicine and newly introduced concepts, such as the precision medicine ecosystem and big data processing, and omics technologies including pharmacogenomics, pharamacometabolomics, pharmacoproteomics, pharmacoepigenomics, connectomics and exposomics. The authors review the current state of omics in psychiatry and the future direction of psychopharmacology as it moves towards precision medicine. Expert commentary: Advances in precision medicine have been facilitated by achievements in multiple fields, including large-scale biological databases, powerful methods for characterizing patients (such as genomics, proteomics, metabolomics, diverse cellular assays, and even social networks and mobile health technologies), and computer-based tools for analyzing large amounts of data.

  7. Precision surveying the principles and geomatics practice

    CERN Document Server

    Ogundare, John Olusegun

    2016-01-01

    A comprehensive overview of high precision surveying, including recent developments in geomatics and their applications This book covers advanced precision surveying techniques, their proper use in engineering and geoscience projects, and their importance in the detailed analysis and evaluation of surveying projects. The early chapters review the fundamentals of precision surveying: the types of surveys; survey observations; standards and specifications; and accuracy assessments for angle, distance and position difference measurement systems. The book also covers network design and 3-D coordinating systems before discussing specialized topics such as structural and ground deformation monitoring techniques and analysis, mining surveys, tunneling surveys, and alignment surveys. Precision Surveying: The Principles and Geomatics Practice: * Covers structural and ground deformation monitoring analysis, advanced techniques in mining and tunneling surveys, and high precision alignment of engineering structures *...

  8. Crop establishment of Silphium perfoliatum by precision seeding

    Directory of Open Access Journals (Sweden)

    Andreas Schäfer

    2015-12-01

    Full Text Available Silphium perfoliatum, a perennial composite from North America, has been found as a promising plant species during the search for alternative biogas substrates. Until now Silphium perfoliatum has been established by the time- and cost-intensive transplanting method. The precision sowing of Silphium perfoliatum reduces the process costs significantly. However, the bulky seed with mildness germination power complicates a well distributed and adequate plant establishment. In field tests a modified precision seeder was used for sowing Silphium perfoliatum which is primarily used for maize sowing.The hole diameter of the singling disc, the sowing coulter and the roller were modified. In the field tests the modified machinery proved an enhanced and uniform field emergence of Silphium perfoliatum.

  9. Precision Islands in the Ising and $O(N)$ Models

    CERN Document Server

    Kos, Filip; Simmons-Duffin, David; Vichi, Alessandro

    2016-01-01

    We make precise determinations of the leading scaling dimensions and operator product expansion (OPE) coefficients in the 3d Ising, $O(2)$, and $O(3)$ models from the conformal bootstrap with mixed correlators. We improve on previous studies by scanning over possible relative values of the leading OPE coefficients, which incorporates the physical information that there is only a single operator at a given scaling dimension. The scaling dimensions and OPE coefficients obtained for the 3d Ising model, $(\\Delta_{\\sigma}, \\Delta_{\\epsilon},\\lambda_{\\sigma\\sigma\\epsilon}, \\lambda_{\\epsilon\\epsilon\\epsilon}) = (0.5181489(10), 1.412625(10), 1.0518537(41), 1.532435(19))$, give the most precise determinations of these quantities to date.

  10. Multilevel models improve precision and speed of IC50 estimates.

    Science.gov (United States)

    Vis, Daniel J; Bombardelli, Lorenzo; Lightfoot, Howard; Iorio, Francesco; Garnett, Mathew J; Wessels, Lodewyk Fa

    2016-05-01

    Experimental variation in dose-response data of drugs tested on cell lines result in inaccuracies in the estimate of a key drug sensitivity characteristic: the IC50. We aim to improve the precision of the half-limiting dose (IC50) estimates by simultaneously employing all dose-responses across all cell lines and drugs, rather than using a single drug-cell line response. We propose a multilevel mixed effects model that takes advantage of all available dose-response data. The new estimates are highly concordant with the currently used Bayesian model when the data are well behaved. Otherwise, the multilevel model is clearly superior. The multilevel model yields a significant reduction of extreme IC50 estimates, an increase in precision and it runs orders of magnitude faster.

  11. Precision requirements and innovative manufacturing for ultrahigh precision laser interferometry of gravitational-wave astronomy

    Science.gov (United States)

    Ni, Wei-Tou; Han, Sen; Jin, Tao

    2016-11-01

    With the LIGO announcement of the first direct detection of gravitational waves (GWs), the GW Astronomy was formally ushered into our age. After one-hundred years of theoretical investigation and fifty years of experimental endeavor, this is a historical landmark not just for physics and astronomy, but also for industry and manufacturing. The challenge and opportunity for industry is precision and innovative manufacturing in large size - production of large and homogeneous optical components, optical diagnosis of large components, high reflectance dielectric coating on large mirrors, manufacturing of components for ultrahigh vacuum of large volume, manufacturing of high attenuating vibration isolation system, production of high-power high-stability single-frequency lasers, production of high-resolution positioning systems etc. In this talk, we address the requirements and methods to satisfy these requirements. Optical diagnosis of large optical components requires large phase-shifting interferometer; the 1.06 μm Phase Shifting Interferometer for testing LIGO optics and the recently built 24" phase-shifting Interferometer in Chengdu, China are examples. High quality mirrors are crucial for laser interferometric GW detection, so as for ring laser gyroscope, high precision laser stabilization via optical cavities, quantum optomechanics, cavity quantum electrodynamics and vacuum birefringence measurement. There are stringent requirements on the substrate materials and coating methods. For cryogenic GW interferometer, appropriate coating on sapphire or silicon are required for good thermal and homogeneity properties. Large ultrahigh vacuum components and high attenuating vibration system together with an efficient metrology system are required and will be addressed. For space interferometry, drag-free technology and weak-light manipulation technology are must. Drag-free technology is well-developed. Weak-light phase locking is demonstrated in the laboratories while

  12. Nanometer-precision linear sorting with synchronized optofluidic dual barriers.

    Science.gov (United States)

    Shi, Yuzhi; Xiong, Sha; Chin, Lip Ket; Zhang, Jingbo; Ser, Wee; Wu, Jiuhui; Chen, Tianning; Yang, Zhenchuan; Hao, Yilong; Liedberg, Bo; Yap, Peng Huat; Tsai, Din Ping; Qiu, Cheng-Wei; Liu, Ai Qun

    2018-01-01

    The past two decades have witnessed the revolutionary development of optical trapping of nanoparticles, most of which deal with trapping stiffness larger than 10 -8 N/m. In this conventional regime, however, it remains a formidable challenge to sort out sub-50-nm nanoparticles with single-nanometer precision, isolating us from a rich flatland with advanced applications of micromanipulation. With an insightfully established roadmap of damping, the synchronization between optical force and flow drag force can be coordinated to attempt the loosely overdamped realm (stiffness, 10 -10 to 10 -8 N/m), which has been challenging. This paper intuitively demonstrates the remarkable functionality to sort out single gold nanoparticles with radii ranging from 30 to 50 nm, as well as 100- and 150-nm polystyrene nanoparticles, with single nanometer precision. The quasi-Bessel optical profile and the loosely overdamped potential wells in the microchannel enable those aforementioned nanoparticles to be separated, positioned, and microscopically oscillated. This work reveals an unprecedentedly meaningful damping scenario that enriches our fundamental understanding of particle kinetics in intriguing optical systems, and offers new opportunities for tumor targeting, intracellular imaging, and sorting small particles such as viruses and DNA.

  13. Precision Stellar and Planetary Astrophysics with TESS and Gaia

    Science.gov (United States)

    Stevens, Daniel J.; KELT Collaboration

    2018-01-01

    There is an ever-present need for precise and accurate stellar parameters, particularly for low-mass stars. For example, some fraction of measured M dwarf radii are inflated and have effective temperatures that are suppressed relative to predictions from models, but the physical cause of these effects is still uncertain. This is exacerbated by the fact that only a handful of M dwarfs -- all from double-lined eclipsing binaries (EBs) -- have both masses and radii measured to 3% or better. In the Gaia era, we can now measure model-independent masses and radii for single-lined EBs, thus expanding the sample of stars with precisely measured parameters by at least an order of magnitude, in principle. I will illustrate how one can combine Gaia parallaxes and broad-band stellar fluxes with the eclipse and radial velocity data to provide model-independent masses and radii. I will present our expected achievable constraints on the masses and radii of single-lined EBs. I will discuss both our current effort to turn several dozens of single-lined EBs discovered by the KELT and HATNet surveys into a catalog of exquisitely characterized stars and exoplanets as well as the prospects for achieving similar science for a much larger number of systems with TESS.

  14. Improved precision with Hologic Apex software.

    Science.gov (United States)

    Fan, B; Lewiecki, E M; Sherman, M; Lu, Y; Miller, P D; Genant, H K; Shepherd, J A

    2008-11-01

    The precision of Hologic Apex v2.0 analysis software is significantly improved from Hologic Delphi v11.2 software and is comparable to GE Lunar Prodigy v7.5 software. Apex and Delphi precisions were, respectively, 1.0% vs. 1.2% (L1-L4 spine), 1.l % vs. 1.3% (total femur), 1.6% vs. 1.9% (femoral neck), and 0.7% vs. 0.9% (dual total femur). Precision of bone mineral density (BMD) measurements by dual-energy X-ray absorptiometry (DXA) is known to vary by manufacturer, model, and technologist. This study evaluated the precision of three analysis versions: Apex v2.0 and Delphi v11.2 (Hologic, Inc.), and Prodigy v7.5 (GE Healthcare, Inc.) independent of technologist skill. Duplicate spine and dual hip scans on 90 women were acquired on both Delphi and Prodigy DXA systems at three clinics. BMD measures were converted to standardized BMD (sBMD) units. Precision errors were described as a root-mean-square (RMS) standard deviations and RMS percent coefficients of variation across the population. Apex and Delphi values were highly correlated (r ranged from 0.90 to 0.99). Excluding the right neck, the Apex precision error was found to be 20% to 25% lower than the Delphi (spine: 1.0% versus 1.2% (p 0.1)). No statistically significant differences were found in the precision error of the Apex and Prodigy (p > 0.05) except for the right neck (2.3% versus 1.8% respectively, p = 0.03). The Apex software has significantly lower precision error compared to Delphi software with similar mean values, and similar precision to that of the Prodigy.

  15. Advances in Precision Medicine: Tailoring Individualized Therapies.

    Science.gov (United States)

    Matchett, Kyle B; Lynam-Lennon, Niamh; Watson, R William; Brown, James A L

    2017-10-25

    The traditional bench-to-bedside pipeline involves using model systems and patient samples to provide insights into pathways deregulated in cancer. This discovery reveals new biomarkers and therapeutic targets, ultimately stratifying patients and informing cohort-based treatment options. Precision medicine (molecular profiling of individual tumors combined with established clinical-pathological parameters) reveals, in real-time, individual patient's diagnostic and prognostic risk profile, informing tailored and tumor-specific treatment plans. Here we discuss advances in precision medicine presented at the Irish Association for Cancer Research Annual Meeting, highlighting examples where personalized medicine approaches have led to precision discovery in individual tumors, informing customized treatment programs.

  16. Mixed-Precision Spectral Deferred Correction: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Grout, Ray W. S.

    2015-09-02

    Convergence of spectral deferred correction (SDC), where low-order time integration methods are used to construct higher-order methods through iterative refinement, can be accelerated in terms of computational effort by using mixed-precision methods. Using ideas from multi-level SDC (in turn based on FAS multigrid ideas), some of the SDC correction sweeps can use function values computed in reduced precision without adversely impacting the accuracy of the final solution. This is particularly beneficial for the performance of combustion solvers such as S3D [6] which require double precision accuracy but are performance limited by the cost of data motion.

  17. Improved precision with Hologic Apex software

    OpenAIRE

    Fan, B.; Lewiecki, E. M.; Sherman, M.; Lu, Y.; Miller, P. D.; Genant, H. K.; Shepherd, J. A.

    2008-01-01

    Summary The precision of Hologic Apex v2.0 analysis software is significantly improved from Hologic Delphi v11.2 software and is comparable to GE Lunar Prodigy v7.5 software. Apex and Delphi precisions were, respectively, 1.0% vs. 1.2% (L1-L4 spine), 1.l % vs. 1.3% (total femur), 1.6% vs. 1.9% (femoral neck), and 0.7% vs. 0.9% (dual total femur). Introduction Precision of bone mineral density (BMD) measurements by dual-energy X-ray absorptiometry (DXA) is known to vary by manufacturer, model,...

  18. Precision mechatronics based on high-precision measuring and positioning systems and machines

    Science.gov (United States)

    Jäger, Gerd; Manske, Eberhard; Hausotte, Tino; Mastylo, Rostyslav; Dorozhovets, Natalja; Hofmann, Norbert

    2007-06-01

    Precision mechatronics is defined in the paper as the science and engineering of a new generation of high precision systems and machines. Nanomeasuring and nanopositioning engineering represents important fields of precision mechatronics. The nanometrology is described as the today's limit of the precision engineering. The problem, how to design nanopositioning machines with uncertainties as small as possible will be discussed. The integration of several optical and tactile nanoprobes makes the 3D-nanopositioning machine suitable for various tasks, such as long range scanning probe microscopy, mask and wafer inspection, nanotribology, nanoindentation, free form surface measurement as well as measurement of microoptics, precision molds, microgears, ring gauges and small holes.

  19. Precision Measurements of Top Quark Production with the ATLAS Detector

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00362178; The ATLAS collaboration

    2016-01-01

    The top quark is the heaviest known fundamental particle. It is the only quark that decays before it hadronises which gives us the unique opportunity to probe the properties of bare quarks and to test perturbative QCD. This overview will focus on a few recent precision top quark measurements by the ATLAS Collaboration at the LHC: Fiducial top pair and single top production cross-sections including differential distributions will be presented and compared with QCD predictions. The results include the first top quark measurements at 13 TeV using data from LHC Run 2.

  20. Precision measurements of top quark production with the ATLAS detector

    CERN Document Server

    Stolte, Philipp; The ATLAS collaboration

    2016-01-01

    The top quark is the heaviest known fundamental particle. As it is the only quark that decays before it hadronizes, this gives us the unique opportunity to probe the properties of bare quarks and to test perturbative QCD. This talk will focus on a few recent precision top quark measurements by the ATLAS Collaboration: fiducial top pair and single top production cross sections including differential distributions will be presented and compared with QCD predictions. The results include the first top quark measurements at 13 TeV using data from LHC run 2.

  1. A compact codimension-two braneworld with precisely one brane

    International Nuclear Information System (INIS)

    Akerblom, Nikolas; Cornelissen, Gunther

    2010-01-01

    Building on earlier work on football-shaped extra dimensions, we construct a compact codimension-two braneworld with precisely one brane. The two extra dimensions topologically represent a 2-torus which is stabilized by a bulk cosmological constant and magnetic flux. The torus has positive constant curvature almost everywhere, except for a single conical singularity at the location of the brane. In contradistinction to the football-shaped case, there is no fine-tuning required for the brane tension. We also present some plausibility arguments why the model should not suffer from serious stability issues.

  2. A Note on "Accuracy" and "Precision"

    Science.gov (United States)

    Stallings, William M.; Gillmore, Gerald M.

    1971-01-01

    Advocates the use of precision" rather than accuracy" in defining reliability. These terms are consistently differentiated in certain sciences. Review of psychological and measurement literature reveals, however, interchangeable usage of the terms in defining reliability. (Author/GS)

  3. Research Institute for Autonomous Precision Guided Systems

    National Research Council Canada - National Science Library

    Sforza, Pasquale

    2003-01-01

    The aim of this project is to leverage the manpower resources dedicated to basic research in technologies relevant to autonomous precision systems at the Air Force Research Laboratory Munitions Directorate (AFRL/MN...

  4. High precision spectrophotometric analysis of thorium

    International Nuclear Information System (INIS)

    Palmieri, H.E.L.

    1984-01-01

    An accurate and precise determination of thorium is proposed. Precision of about 0,1% is required for the determination of macroquantities of thorium when processed. After an extensive literature search concerning this subject, spectrophotometric titration has been chosen, using dissodium ethylenediaminetetraacetate (EDTA) solution and alizarin-S as indicator. In order to obtain such a precision, an amount of 0,025 M EDTA solution precisely measured has been added and the titration was completed with less than 5 ml of 0,0025 M EDTA solution. It is usual to locate the end-point graphically, by plotting added titrant versus absorbance. The non-linear minimum square fit, using the Fletcher e Powell's minimization process and a computer programme. Besides the equivalence point, other parameters of titration were determined: the indicator concentration, the absorbance of the metal-indicator complex, and the stability constants of the metal-indicator and the metal-EDTA complexes. (Author) [pt

  5. Mechanics and Physics of Precise Vacuum Mechanisms

    CERN Document Server

    Deulin, E. A; Panfilov, Yu V; Nevshupa, R. A

    2010-01-01

    In this book the Russian expertise in the field of the design of precise vacuum mechanics is summarized. A wide range of physical applications of mechanism design in electronic, optical-electronic, chemical, and aerospace industries is presented in a comprehensible way. Topics treated include the method of microparticles flow regulation and its determination in vacuum equipment and mechanisms of electronics; precise mechanisms of nanoscale precision based on magnetic and electric rheology; precise harmonic rotary and not-coaxial nut-screw linear motion vacuum feedthroughs with technical parameters considered the best in the world; elastically deformed vacuum motion feedthroughs without friction couples usage; the computer system of vacuum mechanisms failure predicting. This English edition incorporates a number of features which should improve its usefulness as a textbook without changing the basic organization or the general philosophy of presentation of the subject matter of the original Russian work. Exper...

  6. Precise Calculation of Complex Radioactive Decay Chains

    National Research Council Canada - National Science Library

    Harr, Logan J

    2007-01-01

    ...). An application of the exponential moments function is used with a transmutation matrix in the calculation of complex radioactive decay chains to achieve greater precision than can be attained through current methods...

  7. Precision Munition Electro-Sciences Facility

    Data.gov (United States)

    Federal Laboratory Consortium — This facility allows the characterization of the electro-magnetic environment produced by a precision weapon in free flight. It can measure the radiofrequency (RF)...

  8. Prospects for Precision Neutrino Cross Section Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Harris, Deborah A. [Fermilab

    2016-01-28

    The need for precision cross section measurements is more urgent now than ever before, given the central role neutrino oscillation measurements play in the field of particle physics. The definition of precision is something worth considering, however. In order to build the best model for an oscillation experiment, cross section measurements should span a broad range of energies, neutrino interaction channels, and target nuclei. Precision might better be defined not in the final uncertainty associated with any one measurement but rather with the breadth of measurements that are available to constrain models. Current experience shows that models are better constrained by 10 measurements across different processes and energies with 10% uncertainties than by one measurement of one process on one nucleus with a 1% uncertainty. This article describes the current status of and future prospects for the field of precision cross section measurements considering the metric of how many processes, energies, and nuclei have been studied.

  9. Precise subtyping for synchronous multiparty sessions

    Directory of Open Access Journals (Sweden)

    Mariangiola Dezani-Ciancaglini

    2016-02-01

    Full Text Available The notion of subtyping has gained an important role both in theoretical and applicative domains: in lambda and concurrent calculi as well as in programming languages. The soundness and the completeness, together referred to as the preciseness of subtyping, can be considered from two different points of view: operational and denotational. The former preciseness has been recently developed with respect to type safety, i.e. the safe replacement of a term of a smaller type when a term of a bigger type is expected. The latter preciseness is based on the denotation of a type which is a mathematical object that describes the meaning of the type in accordance with the denotations of other expressions from the language. The result of this paper is the operational and denotational preciseness of the subtyping for a synchronous multiparty session calculus. The novelty of this paper is the introduction of characteristic global types to prove the operational completeness.

  10. Laser Metrology System for Precision Pointing

    National Research Council Canada - National Science Library

    Hospodar, Edward

    2003-01-01

    .... The Precision Pointing Hexapod (PPH) at Naval Postgraduate School (NPS) is exactly such a platform initially installed with voice coil actuators and accelerometers on each strut by CSA Engineering Inc...

  11. Thorium spectrophotometric analysis with high precision

    International Nuclear Information System (INIS)

    Palmieri, H.E.L.

    1983-06-01

    An accurate and precise determination of thorium is proposed. Precision of about 0,1% is required for the determination of macroquantities of thorium processed. After an extensive literature search concerning this subject, spectrophotometric titration has been chosen, using disodium ethylenediaminetetraacetate (EDTA) solution and alizarin S as indicator. In order to obtain such a precision, an amount of 0,025 M EDTA solution precisely measured has been added and the titration was completed with less than 5 ml of 0,0025 M EDTA solution. It is usual to locate the end-point graphically, by plotting added titrant versus absorbance. The non-linear minimum square fit, using the Fletcher e Powell's minimization process and a computer program. (author)

  12. [Application of precise radiotherapy in the combined modality therapy of gastrointestinal tract tumors].

    Science.gov (United States)

    Yu, Jin-ming; Meng, Xiang-jiao

    2013-06-01

    Single modality treatment of advanced gastrointestinal cancer has been associated with unfavorable outcomes. Radiotherapy as an important component of the combined modality therapy of gastrointestinal tract tumors may achieve down-staging, increase resection rate while preserving sphincter function, decrease local recurrence rate, and improve survival rate. Precision radiotherapy has better conformity, accuracy, and lower toxicity. Precision radiotherapy will become more and more important in the combined modality therapy of gastrointestinal tract cancer.

  13. Methods for precise photoelectron counting with photomultipliers

    Energy Technology Data Exchange (ETDEWEB)

    Dossi, R.; Ianni, A.; Ranucci, G.; Smirnov, O.Ju. E-mail: smirnov@lngs.infn.itsmipol@cv.jinr.ru

    2000-09-11

    A series of measurements has been performed on a THORN EMI 9351 phototube in order to investigate its response to a low light intensity. Precise procedures to determine the intensity of the incident photon flux have been developed and compared. The data show that the various approaches give consistent and reliable results, thus allowing the precise calibration of the device for applications of photon counting.

  14. Precision nitrogen management of wheat. A review

    OpenAIRE

    Diacono , Mariangela; Rubino , Pietro; Montemurro , Francesco

    2012-01-01

    International audience; Conventional farming has led to extensive use of chemicals and, in turn, to negative environmental impacts such as soil erosion, groundwater pollution and atmosphere contamination. Farming systems should be more sustainable to reach economical and social profitability as well as environmental preservation. A possible solution is to adopt precision agriculture, a win–win option for sustaining food production without degrading the environment. Precision technologies are ...

  15. Precision siting of a particle accelerator

    International Nuclear Information System (INIS)

    Cintra, Jorge Pimentel

    1996-01-01

    Precise location is a specific survey job that involves a high skilled work to avoid unrecoverable results at the project installation. As a function of the different process stages, different specifications can be applied, invoking different instruments: theodolite, measurement tape, distanciometer, invar wire. This paper, based on experience obtained at the installation of particle accelerator equipment, deals with general principles of precise location: tolerance definitions, increasing accuracy techniques, schedule of locations, sensitivity analysis, quality control methods. (author)

  16. A path to precision in the ICU.

    Science.gov (United States)

    Maslove, David M; Lamontagne, Francois; Marshall, John C; Heyland, Daren K

    2017-04-03

    Precision medicine is increasingly touted as a groundbreaking new paradigm in biomedicine. In the ICU, the complexity and ambiguity of critical illness syndromes have been identified as fundamental justifications for the adoption of a precision approach to research and practice. Inherently protean diseases states such as sepsis and acute respiratory distress syndrome have manifestations that are physiologically and anatomically diffuse, and that fluctuate over short periods of time. This leads to considerable heterogeneity among patients, and conditions in which a "one size fits all" approach to therapy can lead to widely divergent results. Current ICU therapy can thus be seen as imprecise, with the potential to realize substantial gains from the adoption of precision medicine approaches. A number of challenges still face the development and adoption of precision critical care, a transition that may occur incrementally rather than wholesale. This article describes a few concrete approaches to addressing these challenges.First, novel clinical trial designs, including registry randomized controlled trials and platform trials, suggest ways in which conventional trials can be adapted to better accommodate the physiologic heterogeneity of critical illness. Second, beyond the "omics" technologies already synonymous with precision medicine, the data-rich environment of the ICU can generate complex physiologic signatures that could fuel precision-minded research and practice. Third, the role of computing infrastructure and modern informatics methods will be central to the pursuit of precision medicine in the ICU, necessitating close collaboration with data scientists. As work toward precision critical care continues, small proof-of-concept studies may prove useful in highlighting the potential of this approach.

  17. Principles of precision medicine in stroke.

    Science.gov (United States)

    Hinman, Jason D; Rost, Natalia S; Leung, Thomas W; Montaner, Joan; Muir, Keith W; Brown, Scott; Arenillas, Juan F; Feldmann, Edward; Liebeskind, David S

    2017-01-01

    The era of precision medicine has arrived and conveys tremendous potential, particularly for stroke neurology. The diagnosis of stroke, its underlying aetiology, theranostic strategies, recurrence risk and path to recovery are populated by a series of highly individualised questions. Moreover, the phenotypic complexity of a clinical diagnosis of stroke makes a simple genetic risk assessment only partially informative on an individual basis. The guiding principles of precision medicine in stroke underscore the need to identify, value, organise and analyse the multitude of variables obtained from each individual to generate a precise approach to optimise cerebrovascular health. Existing data may be leveraged with novel technologies, informatics and practical clinical paradigms to apply these principles in stroke and realise the promise of precision medicine. Importantly, precision medicine in stroke will only be realised once efforts to collect, value and synthesise the wealth of data collected in clinical trials and routine care starts. Stroke theranostics, the ultimate vision of synchronising tailored therapeutic strategies based on specific diagnostic data, demand cerebrovascular expertise on big data approaches to clinically relevant paradigms. This review considers such challenges and delineates the principles on a roadmap for rational application of precision medicine to stroke and cerebrovascular health. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  18. Towards precision medicine; a new biomedical cosmology.

    Science.gov (United States)

    Vegter, M W

    2018-02-10

    Precision Medicine has become a common label for data-intensive and patient-driven biomedical research. Its intended future is reflected in endeavours such as the Precision Medicine Initiative in the USA. This article addresses the question whether it is possible to discern a new 'medical cosmology' in Precision Medicine, a concept that was developed by Nicholas Jewson to describe comprehensive transformations involving various dimensions of biomedical knowledge and practice, such as vocabularies, the roles of patients and physicians and the conceptualisation of disease. Subsequently, I will elaborate my assessment of the features of Precision Medicine with the help of Michel Foucault, by exploring how precision medicine involves a transformation along three axes: the axis of biomedical knowledge, of biomedical power and of the patient as a self. Patients are encouraged to become the managers of their own health status, while the medical domain is reframed as a data-sharing community, characterised by changing power relationships between providers and patients, producers and consumers. While the emerging Precision Medicine cosmology may surpass existing knowledge frameworks; it obscures previous traditions and reduces research-subjects to mere data. This in turn, means that the individual is both subjected to the neoliberal demand to share personal information, and at the same time has acquired the positive 'right' to become a member of the data-sharing community. The subject has to constantly negotiate the meaning of his or her data, which can either enable self-expression, or function as a commanding Superego.

  19. Precision validation of MIPAS-Envisat products

    Directory of Open Access Journals (Sweden)

    C. Piccolo

    2007-01-01

    Full Text Available This paper discusses the variation and validation of the precision, or estimated random error, associated with the ESA Level 2 products from the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS. This quantity represents the propagation of the radiometric noise from the spectra through the retrieval process into the Level 2 profile values. The noise itself varies with time, steadily rising between ice decontamination events, but the Level 2 precision has a greater variation due to the atmospheric temperature which controls the total radiance received. Hence, for all species, the precision varies latitudinally/seasonally with temperature, with a small superimposed temporal structure determined by the degree of ice contamination on the detectors. The precision validation involves comparing two MIPAS retrievals at the intersections of ascending/descending orbits. For 5 days per month of full resolution MIPAS operation, the standard deviation of the matching profile pairs is computed and compared with the precision given in the MIPAS Level 2 data, except for NO2 since it has a large diurnal variation between ascending/descending intersections. Even taking into account the propagation of the pressure-temperature retrieval errors into the VMR retrieval, the standard deviation of the matching pairs is usually a factor 1–2 larger than the precision. This is thought to be due to effects such as horizontal inhomogeneity of the atmosphere and instability of the retrieval.

  20. Precision of measurement of cerebral tissue oxygenation index using near-infrared spectroscopy in preterm neonates

    DEFF Research Database (Denmark)

    Sorensen, Line C; Greisen, Gorm

    2006-01-01

    The use of cerebral tissue oxygenation index (c-TOI) in a clinical setting is limited by doubts concerning the accuracy of the measurements. Since there is no gold standard, validation is difficult. Our modest aim was to quantify the precision of c-TOI doing repeated measurements by reapplying...... variation was 2.9%. The precision of a single measurement of c-TOI was not good. By measuring five times instead of one on each subject, the precision of the mean can be assumed to be comparable to pulse oximetry. This may be too cumbersome for clinical use, but may reduce sample size in research....

  1. Range and Precision of Formant Movement in Pediatric Dysarthria.

    Science.gov (United States)

    Allison, Kristen M; Annear, Lucas; Policicchio, Marisa; Hustad, Katherine C

    2017-07-12

    This study aimed to improve understanding of speech characteristics associated with dysarthria in children with cerebral palsy by analyzing segmental and global formant measures in single-word and sentence contexts. Ten 5-year-old children with cerebral palsy and dysarthria and 10 age-matched, typically developing children participated in this study. Vowel space area and second formant interquartile range were measured from children's elicited productions of single words and sentences. Results showed that the children with dysarthria had significantly smaller vowel space areas than typically developing children in both word and sentence contexts; however, overall ranges of second formant movement did not differ between groups in word or sentence contexts. Additional analysis of single words revealed that, compared to typical children, children with dysarthria had smaller second formant interquartile ranges in single words with phonetic contexts requiring large changes in vocal tract configuration, but not in single words with monophthongs. Results of this study suggest that children with dysarthria may not have globally reduced ranges of articulatory movement compared to typically developing peers; however, they do exhibit reduced precision in producing phonetic targets.

  2. Atomically Precise Metal Nanoclusters for Catalytic Application

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Rongchao [Carnegie Mellon Univ., Pittsburgh, PA (United States)

    2016-11-18

    The central goal of this project is to explore the catalytic application of atomically precise gold nanoclusters. By solving the total structures of ligand-protected nanoclusters, we aim to correlate the catalytic properties of metal nanoclusters with their atomic/electronic structures. Such correlation unravel some fundamental aspects of nanocatalysis, such as the nature of particle size effect, origin of catalytic selectivity, particle-support interactions, the identification of catalytically active centers, etc. The well-defined nanocluster catalysts mediate the knowledge gap between single crystal model catalysts and real-world conventional nanocatalysts. These nanoclusters also hold great promise in catalyzing certain types of reactions with extraordinarily high selectivity. These aims are in line with the overall goals of the catalytic science and technology of DOE and advance the BES mission “to support fundamental research to understand, predict, and ultimately control matter and energy at the level of electrons, atoms, and molecules”. Our group has successfully prepared different sized, robust gold nanoclusters protected by thiolates, such as Au25(SR)18, Au28(SR)20, Au38(SR)24, Au99(SR)42, Au144(SR)60, etc. Some of these nanoclusters have been crystallographically characterized through X-ray crystallography. These ultrasmall nanoclusters (< 2 nm diameter) exhibit discrete electronic structures due to quantum size effect, as opposed to quasicontinuous band structure of conventional metal nanoparticles or bulk metals. The available atomic structures (metal core plus surface ligands) of nanoclusters serve as the basis for structure-property correlations. We have investigated the unique catalytic properties of nanoclusters (i.e. not observed in conventional nanogold catalysts) and revealed the structure-selectivity relationships. Highlights of our

  3. Multicore fibre photonic lanterns for precision radial velocity Science

    Science.gov (United States)

    Gris-Sánchez, Itandehui; Haynes, Dionne M.; Ehrlich, Katjana; Haynes, Roger; Birks, Tim A.

    2018-04-01

    Incomplete fibre scrambling and fibre modal noise can degrade high-precision spectroscopic applications (typically high spectral resolution and high signal to noise). For example, it can be the dominating error source for exoplanet finding spectrographs, limiting the maximum measurement precision possible with such facilities. This limitation is exacerbated in the next generation of infra-red based systems, as the number of modes supported by the fibre scales inversely with the wavelength squared and more modes typically equates to better scrambling. Substantial effort has been made by major research groups in this area to improve the fibre link performance by employing non-circular fibres, double scramblers, fibre shakers, and fibre stretchers. We present an original design of a multicore fibre (MCF) terminated with multimode photonic lantern ports. It is designed to act as a relay fibre with the coupling efficiency of a multimode fibre (MMF), modal stability similar to a single-mode fibre and low loss in a wide range of wavelengths (380 nm to 860 nm). It provides phase and amplitude scrambling to achieve a stable near field and far-field output illumination pattern despite input coupling variations, and low modal noise for increased stability for high signal-to-noise applications such as precision radial velocity (PRV) science. Preliminary results are presented for a 511-core MCF and compared with current state of the art octagonal fibre.

  4. Innovations in precision seed drilling technology: successes or failures?

    Directory of Open Access Journals (Sweden)

    Johannes Benninger

    2016-06-01

    Full Text Available In view of the development of various technological alternatives in precision seed drilling, it has become a matter of research whether there are clear criteria for the success or failure of technological innovations. Around the turn to the 20th century, two very different precision seed drill methods were developed almost at the same time. Band seeding made it possible to achieve nearly perfect single grain sowing. For this purpose, individual, equally spaced seeds were embedded into bands of paper or cotton. In the field, these seed tapes were then unreeled from large drums. The pneumatic system proposed in 1897, by contrast, introduced grain singling using a vacuum for the first time. Although band seeding presented a satisfactory technological solution, it was never widely applied. Pneumatic systems, on the other hand, took long to catch on and only started to be successful in the late 1960s. Up to then, these innovative systems had to be considered as failures. Changing the period under review, however, may completely reverse the assessment of whether an innovation is a success or a failure.

  5. Precision forging technology for aluminum alloy

    Science.gov (United States)

    Deng, Lei; Wang, Xinyun; Jin, Junsong; Xia, Juchen

    2018-03-01

    Aluminum alloy is a preferred metal material for lightweight part manufacturing in aerospace, automobile, and weapon industries due to its good physical properties, such as low density, high specific strength, and good corrosion resistance. However, during forging processes, underfilling, folding, broken streamline, crack, coarse grain, and other macro- or microdefects are easily generated because of the deformation characteristics of aluminum alloys, including narrow forgeable temperature region, fast heat dissipation to dies, strong adhesion, high strain rate sensitivity, and large flow resistance. Thus, it is seriously restricted for the forged part to obtain precision shape and enhanced property. In this paper, progresses in precision forging technologies of aluminum alloy parts were reviewed. Several advanced precision forging technologies have been developed, including closed die forging, isothermal die forging, local loading forging, metal flow forging with relief cavity, auxiliary force or vibration loading, casting-forging hybrid forming, and stamping-forging hybrid forming. High-precision aluminum alloy parts can be realized by controlling the forging processes and parameters or combining precision forging technologies with other forming technologies. The development of these technologies is beneficial to promote the application of aluminum alloys in manufacturing of lightweight parts.

  6. Research on tracking precision of the heliostat

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Wenfeng [Himin Solar Energy Group Co., Ltd, Dezhou (China); CAS, Beijing (China). Inst. of Electrical Engineering; Wang, Zhifeng [CAS, Beijing (China). Inst. of Electrical Engineering

    2008-07-01

    The tracking precision and manufacture cost of the heliostats is obviously crucial to the system efficiency and its investment scale in a tower power plant. An open loop control system according to astronomic formula of high precision was proposed in this paper. The astronomical formulae to calculate the solar zenith and azimuth angles with uncertainties of {+-}0.005 mrad (milli-radian). This System was built in 2005 at De Zhou China. The structure of this control system is 'PC-PLC-PLC'. Taking account of the inevitable error occurred during the heliostat's installation, a mathematic model was established in this paper. The tracking control precision of this system is 0.17 mrad. Total error stack-ups for tracking and beam quality in calm winds is about 3 mrad. Drive systems with large gear ratios were designed to give sufficiently rapid movement in high wind condition with sufficient precision to meet the focusing requirement which minimizing motor power and manufacturing costs. After the analysis on the gear down ratio of the drive system in a heliostat unit, it came to the conclusion that having one inverter connected to two common motors with time-sharing control can not only meet the tracking precision requirement but achieve low cost. (orig.)

  7. Single-Mode VCSELs

    Science.gov (United States)

    Larsson, Anders; Gustavsson, Johan S.

    The only active transverse mode in a truly single-mode VCSEL is the fundamental mode with a near Gaussian field distribution. A single-mode VCSEL produces a light beam of higher spectral purity, higher degree of coherence and lower divergence than a multimode VCSEL and the beam can be more precisely shaped and focused to a smaller spot. Such beam properties are required in many applications. In this chapter, after discussing applications of single-mode VCSELs, we introduce the basics of fields and modes in VCSELs and review designs implemented for single-mode emission from VCSELs in different materials and at different wavelengths. This includes VCSELs that are inherently single-mode as well as inherently multimode VCSELs where higher-order modes are suppressed by mode selective gain or loss. In each case we present the current state-of-the-art and discuss pros and cons. At the end, a specific example with experimental results is provided and, as a summary, the most promising designs based on current technologies are identified.

  8. Advances in Precision Medicine: Tailoring Individualized Therapies

    Directory of Open Access Journals (Sweden)

    Kyle B. Matchett

    2017-10-01

    Full Text Available The traditional bench-to-bedside pipeline involves using model systems and patient samples to provide insights into pathways deregulated in cancer. This discovery reveals new biomarkers and therapeutic targets, ultimately stratifying patients and informing cohort-based treatment options. Precision medicine (molecular profiling of individual tumors combined with established clinical-pathological parameters reveals, in real-time, individual patient’s diagnostic and prognostic risk profile, informing tailored and tumor-specific treatment plans. Here we discuss advances in precision medicine presented at the Irish Association for Cancer Research Annual Meeting, highlighting examples where personalized medicine approaches have led to precision discovery in individual tumors, informing customized treatment programs.

  9. The Future of Precision Medicine in Oncology.

    Science.gov (United States)

    Millner, Lori M; Strotman, Lindsay N

    2016-09-01

    Precision medicine in oncology focuses on identifying which therapies are most effective for each patient based on genetic characterization of the cancer. Traditional chemotherapy is cytotoxic and destroys all cells that are rapidly dividing. The foundation of precision medicine is targeted therapies and selecting patients who will benefit most from these therapies. One of the newest aspects of precision medicine is liquid biopsy. A liquid biopsy includes analysis of circulating tumor cells, cell-free nucleic acid, or exosomes obtained from a peripheral blood draw. These can be studied individually or in combination and collected serially, providing real-time information as a patient's cancer changes. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Nanotechnology: The new perspective in precision agriculture

    Directory of Open Access Journals (Sweden)

    Joginder Singh Duhan

    2017-09-01

    Full Text Available Nanotechnology is an interdisciplinary research field. In recent past efforts have been made to improve agricultural yield through exhaustive research in nanotechnology. The green revolution resulted in blind usage of pesticides and chemical fertilizers which caused loss of soil biodiversity and developed resistance against pathogens and pests as well. Nanoparticle-mediated material delivery to plants and advanced biosensors for precision farming are possible only by nanoparticles or nanochips. Nanoencapsulated conventional fertilizers, pesticides and herbicides helps in slow and sustained release of nutrients and agrochemicals resulting in precise dosage to the plants. Nanotechnology based plant viral disease detection kits are also becoming popular and are useful in speedy and early detection of viral diseases. In this article, the potential uses and benefits of nanotechnology in precision agriculture are discussed. The modern nanotechnology based tools and techniques have the potential to address the various problems of conventional agriculture and can revolutionize this sector.

  11. Nanotechnology: The new perspective in precision agriculture.

    Science.gov (United States)

    Duhan, Joginder Singh; Kumar, Ravinder; Kumar, Naresh; Kaur, Pawan; Nehra, Kiran; Duhan, Surekha

    2017-09-01

    Nanotechnology is an interdisciplinary research field. In recent past efforts have been made to improve agricultural yield through exhaustive research in nanotechnology. The green revolution resulted in blind usage of pesticides and chemical fertilizers which caused loss of soil biodiversity and developed resistance against pathogens and pests as well. Nanoparticle-mediated material delivery to plants and advanced biosensors for precision farming are possible only by nanoparticles or nanochips. Nanoencapsulated conventional fertilizers, pesticides and herbicides helps in slow and sustained release of nutrients and agrochemicals resulting in precise dosage to the plants. Nanotechnology based plant viral disease detection kits are also becoming popular and are useful in speedy and early detection of viral diseases. In this article, the potential uses and benefits of nanotechnology in precision agriculture are discussed. The modern nanotechnology based tools and techniques have the potential to address the various problems of conventional agriculture and can revolutionize this sector.

  12. Single frequency semiconductor lasers

    CERN Document Server

    Fang, Zujie; Chen, Gaoting; Qu, Ronghui

    2017-01-01

    This book systematically introduces the single frequency semiconductor laser, which is widely used in many vital advanced technologies, such as the laser cooling of atoms and atomic clock, high-precision measurements and spectroscopy, coherent optical communications, and advanced optical sensors. It presents both the fundamentals and characteristics of semiconductor lasers, including basic F-P structure and monolithic integrated structures; interprets laser noises and their measurements; and explains mechanisms and technologies relating to the main aspects of single frequency lasers, including external cavity lasers, frequency stabilization technologies, frequency sweeping, optical phase locked loops, and so on. It paints a clear, physical picture of related technologies and reviews new developments in the field as well. It will be a useful reference to graduate students, researchers, and engineers in the field.

  13. High precision detector robot arm system

    Energy Technology Data Exchange (ETDEWEB)

    Shu, Deming; Chu, Yong

    2017-01-31

    A method and high precision robot arm system are provided, for example, for X-ray nanodiffraction with an X-ray nanoprobe. The robot arm system includes duo-vertical-stages and a kinematic linkage system. A two-dimensional (2D) vertical plane ultra-precision robot arm supporting an X-ray detector provides positioning and manipulating of the X-ray detector. A vertical support for the 2D vertical plane robot arm includes spaced apart rails respectively engaging a first bearing structure and a second bearing structure carried by the 2D vertical plane robot arm.

  14. Non-precision approach in manual mode

    Directory of Open Access Journals (Sweden)

    М. В. Коршунов

    2013-07-01

    Full Text Available Considered is the method of non-precision approach of an aircraft in the manual mode with a constant angle of path. Advantage of this method consists in the fact that the construction of approach with a constant angle of path provides the stable path of flight. It is also considered a detailed analysis of the possibility of the approach by the above-mentioned method. Conclusions contain recommendations regarding the use of the described method of non-precision approach during training flights.

  15. Fundamental limits of scintillation detector timing precision

    International Nuclear Information System (INIS)

    Derenzo, Stephen E; Choong, Woon-Seng; Moses, William W

    2014-01-01

    In this paper we review the primary factors that affect the timing precision of a scintillation detector. Monte Carlo calculations were performed to explore the dependence of the timing precision on the number of photoelectrons, the scintillator decay and rise times, the depth of interaction uncertainty, the time dispersion of the optical photons (modeled as an exponential decay), the photodetector rise time and transit time jitter, the leading-edge trigger level, and electronic noise. The Monte Carlo code was used to estimate the practical limits on the timing precision for an energy deposition of 511 keV in 3 mm × 3 mm × 30 mm Lu 2 SiO 5 :Ce and LaBr 3 :Ce crystals. The calculated timing precisions are consistent with the best experimental literature values. We then calculated the timing precision for 820 cases that sampled scintillator rise times from 0 to 1.0 ns, photon dispersion times from 0 to 0.2 ns, photodetector time jitters from 0 to 0.5 ns fwhm, and A from 10 to 10 000 photoelectrons per ns decay time. Since the timing precision R was found to depend on A −1/2  more than any other factor, we tabulated the parameter B, where R = BA −1/2 . An empirical analytical formula was found that fit the tabulated values of B with an rms deviation of 2.2% of the value of B. The theoretical lower bound of the timing precision was calculated for the example of 0.5 ns rise time, 0.1 ns photon dispersion, and 0.2 ns fwhm photodetector time jitter. The lower bound was at most 15% lower than leading-edge timing discrimination for A from 10 to 10 000 photoelectrons ns −1 . A timing precision of 8 ps fwhm should be possible for an energy deposition of 511 keV using currently available photodetectors if a theoretically possible scintillator were developed that could produce 10 000 photoelectrons ns −1 . (paper)

  16. Pushing the precision frontier in Collider Physics

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    The interplay between precise theory predictions and experimental measurements has written a success story in particle physics. After a brief journey into history we will review recent developments which have led  to "revolutions" with regard to precision calculations and to new insights into the structure of quantum field theory. The second part of the talk will focus on phenomenology, especially on Higgs boson pair production as a window to physics beyond the Standard Model, manifesting itself in a modification of those Higgs couplings which are still to a large extent unconstrained, in particular the Higgs boson self-coupling.

  17. Watching single molecules dance

    Science.gov (United States)

    Mehta, Amit Dinesh

    Molecular motors convert chemical energy, from ATP hydrolysis or ion flow, into mechanical motion. A variety of increasingly precise mechanical probes have been developed to monitor and perturb these motors at the single molecule level. Several outstanding questions can be best approached at the single molecule level. These include: how far does a motor progress per energy quanta consumed? how does its reaction cycle respond to load? how many productive catalytic cycles can it undergo per diffusional encounter with its track? and what is the mechanical stiffness of a single molecule connection? A dual beam optical trap, in conjunction with in vitro ensemble motility assays, has been used to characterize two members of the myosin superfamily: muscle myosin II and chick brain myosin V. Both move the helical polymer actin, but myosin II acts in large ensembles to drive muscle contraction or cytokinesis, while myosin V acts in small numbers to transport vesicles. An optical trapping apparatus was rendered sufficiently precise to identify a myosin working stroke with 1nm or so, barring systematic errors such as those perhaps due to random protein orientations. This and other light microscopic motility assays were used to characterize myosin V: unlike myosin II this vesicle transport protein moves through many increments of travel while remaining strongly bound to a single actin filament. The step size, stall force, and travel distance of myosin V reveal a remarkably efficient motor capable of moving along a helical track for over a micrometer without significantly spiraling around it. Such properties are fully consistent with the putative role of an organelle transport motor, present in small numbers to maintain movement over long ranges relative to cellular size scales. The contrast between myosin II and myosin V resembles that between a human running on the moon and one walking on earth, where the former allows for faster motion when in larger ensembles but for less

  18. Precision Medicine In Action | NIH MedlinePlus the Magazine

    Science.gov (United States)

    ... page please turn JavaScript on. Feature: NIH Precision Medicine Initiative Precision Medicine In Action Past Issues / Fall 2015 Table of ... Dishman "I am totally motivated to support precision medicine because I am one of the early prototype ...

  19. Ionospheric Modeling for Precise GNSS Applications

    NARCIS (Netherlands)

    Memarzadeh, Y.

    2009-01-01

    The main objective of this thesis is to develop a procedure for modeling and predicting ionospheric Total Electron Content (TEC) for high precision differential GNSS applications. As the ionosphere is a highly dynamic medium, we believe that to have a reliable procedure it is necessary to transfer

  20. Artificial intelligence, physiological genomics, and precision medicine.

    Science.gov (United States)

    Williams, Anna Marie; Liu, Yong; Regner, Kevin R; Jotterand, Fabrice; Liu, Pengyuan; Liang, Mingyu

    2018-04-01

    Big data are a major driver in the development of precision medicine. Efficient analysis methods are needed to transform big data into clinically-actionable knowledge. To accomplish this, many researchers are turning toward machine learning (ML), an approach of artificial intelligence (AI) that utilizes modern algorithms to give computers the ability to learn. Much of the effort to advance ML for precision medicine has been focused on the development and implementation of algorithms and the generation of ever larger quantities of genomic sequence data and electronic health records. However, relevance and accuracy of the data are as important as quantity of data in the advancement of ML for precision medicine. For common diseases, physiological genomic readouts in disease-applicable tissues may be an effective surrogate to measure the effect of genetic and environmental factors and their interactions that underlie disease development and progression. Disease-applicable tissue may be difficult to obtain, but there are important exceptions such as kidney needle biopsy specimens. As AI continues to advance, new analytical approaches, including those that go beyond data correlation, need to be developed and ethical issues of AI need to be addressed. Physiological genomic readouts in disease-relevant tissues, combined with advanced AI, can be a powerful approach for precision medicine for common diseases.

  1. Precise Interval Timer for Software Defined Radio

    Science.gov (United States)

    Pozhidaev, Aleksey (Inventor)

    2014-01-01

    A precise digital fractional interval timer for software defined radios which vary their waveform on a packet-by-packet basis. The timer allows for variable length in the preamble of the RF packet and allows to adjust boundaries of the TDMA (Time Division Multiple Access) Slots of the receiver of an SDR based on the reception of the RF packet of interest.

  2. Mechanical precision of the BMl98

    CERN Document Server

    Cerioni, S; Esposito, B; Maccarrone, G

    1999-01-01

    The BML 98 has been measured on the X-ray Cern facility. The data have been analyzed and compared with the Frascati metrology results on the jig used for the assembly. The results are satisfactory both for global precision (the 20 µm goal has been achieved ) and for systematics ( the metrology results are well reproduced ).

  3. Bringing Precision Medicine to Community Oncologists.

    Science.gov (United States)

    2017-01-01

    Quest Diagnostics has teamed up with Memorial Sloan Kettering Cancer Center and IBM Watson Health to offer IBM Watson Genomics to its network of community cancer centers and hospitals. This new service aims to advance precision medicine by combining genomic tumor sequencing with the power of cognitive computing. ©2017 American Association for Cancer Research.

  4. Surfaces in Precision Engineering, Microengineering and Nanotechnology

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Kunzmann, H.; Peggs, G. N.

    2003-01-01

    with precision engineering, microengineering and nanotechnology are presented, encompassing surfaces in computers, MEMS, biomedical systems, light and X-ray optics, as well as in chemical systems. Surface properties at micro and nanoscale are considered, including geometry as well as physical and chemical...

  5. Big Data's Role in Precision Public Health.

    Science.gov (United States)

    Dolley, Shawn

    2018-01-01

    Precision public health is an emerging practice to more granularly predict and understand public health risks and customize treatments for more specific and homogeneous subpopulations, often using new data, technologies, and methods. Big data is one element that has consistently helped to achieve these goals, through its ability to deliver to practitioners a volume and variety of structured or unstructured data not previously possible. Big data has enabled more widespread and specific research and trials of stratifying and segmenting populations at risk for a variety of health problems. Examples of success using big data are surveyed in surveillance and signal detection, predicting future risk, targeted interventions, and understanding disease. Using novel big data or big data approaches has risks that remain to be resolved. The continued growth in volume and variety of available data, decreased costs of data capture, and emerging computational methods mean big data success will likely be a required pillar of precision public health into the future. This review article aims to identify the precision public health use cases where big data has added value, identify classes of value that big data may bring, and outline the risks inherent in using big data in precision public health efforts.

  6. High Precision Pressure Measurement with a Funnel

    Science.gov (United States)

    Lopez-Arias, T.; Gratton, L. M.; Oss, S.

    2008-01-01

    A simple experimental device for high precision differential pressure measurements is presented. Its working mechanism recalls that of a hydraulic press, where pressure is supplied by insufflating air under a funnel. As an application, we measure air pressure inside a soap bubble. The soap bubble is inflated and connected to a funnel which is…

  7. Precision Machining Technologies. Occupational Competency Analysis Profile.

    Science.gov (United States)

    Ohio State Univ., Columbus. Vocational Instructional Materials Lab.

    This Occupational Competency Analysis Profile (OCAP), which is one of a series of OCAPs developed to identify the skills that Ohio employers deem necessary to entering a given occupation/occupational area, lists the occupational, academic, and employability skills required of individuals entering the occupation of precision machinist. The…

  8. Precision Machining Technology. Technical Committee Report.

    Science.gov (United States)

    Idaho State Dept. of Education, Boise. Div. of Vocational Education.

    This Technical Committee Report prepared by industry representatives in Idaho lists the skills currently necessary for an employee in that state to obtain a job in precision machining technology, retain a job once hired, and advance in that occupational field. (Task lists are grouped according to duty areas generally used in industry settings, and…

  9. Precision Engineering within the National Ignition Campaign

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, J S; Carlisle, K; Klingmann, J L; Geraghty, P; Saito, T T; Montesanti, R C

    2010-02-17

    In this very brief talk, we'll discuss how precision engineering impacts 4 key areas of NIF: (1) Diamond turning of KDP crystals; (2) Mitigation of laser damage on optics; (3) Alignment of lasers, targets, diagnostics; (4) Target fabrication.

  10. Micropropulsion Systems for Precision Controlled Space Flight

    DEFF Research Database (Denmark)

    Larsen, Jack

    of the disturbance forces and their influence on a precision controlled spacecraft, is used to deduce the requirements for a micropropulsion system compensating for these. Following this an LTCC based resistojet microthruster is developed and fabricated, utilizing water as fuel. Towards the end of the project...

  11. High-precision positioning of radar scatterers

    NARCIS (Netherlands)

    Dheenathayalan, P.; Small, D.; Schubert, A.; Hanssen, R.F.

    2016-01-01

    Remote sensing radar satellites cover wide areas and provide spatially dense measurements, with millions of scatterers. Knowledge of the precise position of each radar scatterer is essential to identify the corresponding object and interpret the estimated deformation. The absolute position accuracy

  12. Ultra-precision: enabling our future.

    Science.gov (United States)

    Shore, Paul; Morantz, Paul

    2012-08-28

    This paper provides a perspective on the development of ultra-precision technologies: What drove their evolution and what do they now promise for the future as we face the consequences of consumption of the Earth's finite resources? Improved application of measurement is introduced as a major enabler of mass production, and its resultant impact on wealth generation is considered. This paper identifies the ambitions of the defence, automotive and microelectronics sectors as important drivers of improved manufacturing accuracy capability and ever smaller feature creation. It then describes how science fields such as astronomy have presented significant precision engineering challenges, illustrating how these fields of science have achieved unprecedented levels of accuracy, sensitivity and sheer scale. Notwithstanding their importance to science understanding, many science-driven ultra-precision technologies became key enablers for wealth generation and other well-being issues. Specific ultra-precision machine tools important to major astronomy programmes are discussed, as well as the way in which subsequently evolved machine tools made at the beginning of the twenty-first century, now provide much wider benefits.

  13. Precision holography for non-conformal branes

    NARCIS (Netherlands)

    Kanitscheider, I.; Skenderis, K.; Taylor, M.

    2008-01-01

    We set up precision holography for the non-conformal branes preserving 16 supersymmetries. The near-horizon limit of all such p-brane solutions with p <= 4, including the case of fundamental string solutions, is conformal to AdS(p+2) x S8-p with a linear dilaton. We develop holographic

  14. Movements, timing and precision of drummers

    DEFF Research Database (Denmark)

    Dahl, Sofia

    2018-01-01

    Percussion instruments vary a great deal in material properties and characteristics of the interaction. Most drums, however, produce sounds with well defined onsets and contact time between player and instrument can be very brief. Players of percussion need to have precise control of timing and s...

  15. Fundamental constants: The teamwork of precision

    Science.gov (United States)

    Myers, Edmund G.

    2014-02-01

    A new value for the atomic mass of the electron is a link in a chain of measurements that will enable a test of the standard model of particle physics with better than part-per-trillion precision. See Letter p.467

  16. Precision cryogenic temperature data acquisition system

    International Nuclear Information System (INIS)

    Farah, Y.; Sondericker, J.H.

    1985-01-01

    A Multiplexed Temperature Data Acquisition System with an overall precision of +-25 ppM has been designed using state-of-the-art electronics to accurately read temperature between 2.4 K and 600 K from pre-calibrated transducers such as germanium, silicon diode, thermistor or platinum temperature sensors

  17. A fluence device for precise radiation dosimetry

    International Nuclear Information System (INIS)

    Arnott, R.G.T.; Peak, M.J.

    1979-01-01

    An instrument is described which has been designed to ensure precise positioning of samples and sensing devices in three dimensions at all times during irradiation procedures. The system, which is both robust and sensitive, overcomes difficulties experienced when slight variations in the positioning of a sample under irradiation results in large changes in fluence. (UK)

  18. Digitalization of highly precise fluxgate magnetometers

    DEFF Research Database (Denmark)

    Cerman, Ales; Kuna, A.; Ripka, P.

    2005-01-01

    the Delta-Sigma ADCs are mostly used for the digitalization of the highly precise fluxgate magnetorneters. The relevant part of the paper demonstrates some pitfalls of their application studied during the design of the magnetometer for the new Czech scientific satellite MIMOSA. The part discussing...

  19. Fiber Scrambling for High Precision Spectrographs

    Science.gov (United States)

    Kaplan, Zachary; Spronck, J. F. P.; Fischer, D.

    2011-05-01

    The detection of Earth-like exoplanets with the radial velocity method requires extreme Doppler precision and long-term stability in order to measure tiny reflex velocities in the host star. Recent planet searches have led to the detection of so called "super-Earths” (up to a few Earth masses) that induce radial velocity changes of about 1 m/s. However, the detection of true Earth analogs requires a precision of 10 cm/s. One of the largest factors limiting Doppler precision is variation in the Point Spread Function (PSF) from observation to observation due to changes in the illumination of the slit and spectrograph optics. Thus, this stability has become a focus of current instrumentation work. Fiber optics have been used since the 1980's to couple telescopes to high-precision spectrographs, initially for simpler mechanical design and control. However, fiber optics are also naturally efficient scramblers. Scrambling refers to a fiber's ability to produce an output beam independent of input. Our research is focused on characterizing the scrambling properties of several types of fibers, including circular, square and octagonal fibers. By measuring the intensity distribution after the fiber as a function of input beam position, we can simulate guiding errors that occur at an observatory. Through this, we can determine which fibers produce the most uniform outputs for the severest guiding errors, improving the PSF and allowing sub-m/s precision. However, extensive testing of fibers of supposedly identical core diameter, length and shape from the same manufacturer has revealed the "personality” of individual fibers. Personality describes differing intensity patterns for supposedly duplicate fibers illuminated identically. Here, we present our results on scrambling characterization as a function of fiber type, while studying individual fiber personality.

  20. High-precision absolute distance measurement using dual-laser frequency scanned interferometry under realistic conditions

    International Nuclear Information System (INIS)

    Yang, H.-J.; Nyberg, Sven; Riles, Keith

    2007-01-01

    In this paper, we report on new high-precision absolute distance measurements performed with frequency scanned interferometry using a pair of single-mode optical fibers. Absolute distances were determined by counting the interference fringes produced while scanning the frequencies of the two chopped lasers. High-finesse Fabry-Perot interferometers were used to determine frequency changes during scanning. Dual lasers with oppositely scanning directions, combined with a multi-distance-measurement technique previously reported, were used to cancel drift errors and to suppress vibration effects and interference fringe uncertainties. Under realistic conditions, a precision about 0.2μm was achieved for a distance of 0.41m. With a precision that exceeds requirements, the frequency scanned interferometry is a promising high-precision optical alignment technique for International Linear Collider silicon tracker detector

  1. A Dynamic Precision Evaluation Method for the Star Sensor in the Stellar-Inertial Navigation System.

    Science.gov (United States)

    Lu, Jiazhen; Lei, Chaohua; Yang, Yanqiang

    2017-06-28

    Integrating the advantages of INS (inertial navigation system) and the star sensor, the stellar-inertial navigation system has been used for a wide variety of applications. The star sensor is a high-precision attitude measurement instrument; therefore, determining how to validate its accuracy is critical in guaranteeing its practical precision. The dynamic precision evaluation of the star sensor is more difficult than a static precision evaluation because of dynamic reference values and other impacts. This paper proposes a dynamic precision verification method of star sensor with the aid of inertial navigation device to realize real-time attitude accuracy measurement. Based on the gold-standard reference generated by the star simulator, the altitude and azimuth angle errors of the star sensor are calculated for evaluation criteria. With the goal of diminishing the impacts of factors such as the sensors' drift and devices, the innovative aspect of this method is to employ static accuracy for comparison. If the dynamic results are as good as the static results, which have accuracy comparable to the single star sensor's precision, the practical precision of the star sensor is sufficiently high to meet the requirements of the system specification. The experiments demonstrate the feasibility and effectiveness of the proposed method.

  2. Linear accelerator based stereotactic radiosurgery with micro multi-leaf collimator : technological advancement in precision radiotherapy

    International Nuclear Information System (INIS)

    Dayananda, S.; Kinhikar, R.A.; Saju, Sherley; Deshpande, D.D.; Jalali, R.; Sarin, R.; Shrivastava, S.K.; Dinshaw, K.A.

    2003-01-01

    Stereotactic Radiosurgery (SRS) is an advancement on precision radiotherapy, in which stereo tactically guided localized high dose is delivered to the lesion (target) in a single fraction, while sparing the surrounding normal tissue. Radiosurgery has been used to treat variety of benign and malignant lesions as well as functional disorders in brain such as arteriovenous malformation (AVM), acoustic neuroma, solitary primary brain tumor, single metastasis, pituitary adenoma etc

  3. Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems

    Science.gov (United States)

    Peters, Christopher J.; Danehy, Paul M.; Bathel, Brett F.; Jiang, Naibo; Calvert, Nathan D.; Miles, Richard B.

    2015-01-01

    Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

  4. A more precise determination of half-life of 213Po

    International Nuclear Information System (INIS)

    Wawryszczuk, J.; Gromov, K.Ya.; Zlokazov, V.B.; Kalinnikov, V.G.; Morozov, V.A.; Morozova, N.V.; Fominykh, V.I.; Tsupko-Sitnikov, V.V.; Churin, I.N.

    1997-01-01

    The measurement of half-life of the ground state 213 Po was performed by the three dimensional single crystal scintillation time spectrometer. A more precise value of this nuclear constant - T 1 /2=3.70(3) μm has been received. (author)

  5. Aspects of precision and accuracy in neutron activation analysis

    International Nuclear Information System (INIS)

    Heydorn, K.

    1980-03-01

    Analytical results without systematic errors and with accurately known random errors are normally distributed around their true values. Such results may be produced by means of neutron activation analysis both with and without radiochemical separation. When all sources of random variation are known a priori, their effect may be combined with the Poisson statistics characteristic of the counting process, and the standard deviation of a single analytical result may be estimated. The various steps of a complete neutron activation analytical procedure are therefore studied in detail with respect to determining their contribution to the overall variability of the final result. Verification of the estimated standard deviation is carried out by demonstrating the absence of significant unknown random errors through analysing, in replicate, samples covering the range of concentrations and matrices anticipated in actual use. Agreement between the estimated and the observed variability of replicate results is then tested by a simple statistic T based on the chi-square distribution. It is found that results from neutron activation analysis on biological samples can be brought into statistical control. In routine application of methods in statistical control the same statistical test may be used for quality control when some of the actual samples are analysed in duplicate. This analysis of precision serves to detect unknown or unexpected sources of variation of the analytical results, and both random and systematic errors have been discovered in practical trace element investigations in different areas of research. Particularly, at the ultratrace level of concentration where there are few or no standard reference materials for ascertaining the accuracy of results, the proposed quality control based on the analysis of precision combined with neutron activation analysis with radiochemical separation, with an a priori precision independent of the level of concentration, becomes a

  6. A primer on precision medicine informatics.

    Science.gov (United States)

    Sboner, Andrea; Elemento, Olivier

    2016-01-01

    In this review, we describe key components of a computational infrastructure for a precision medicine program that is based on clinical-grade genomic sequencing. Specific aspects covered in this review include software components and hardware infrastructure, reporting, integration into Electronic Health Records for routine clinical use and regulatory aspects. We emphasize informatics components related to reproducibility and reliability in genomic testing, regulatory compliance, traceability and documentation of processes, integration into clinical workflows, privacy requirements, prioritization and interpretation of results to report based on clinical needs, rapidly evolving knowledge base of genomic alterations and clinical treatments and return of results in a timely and predictable fashion. We also seek to differentiate between the use of precision medicine in germline and cancer. © The Author 2015. Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  7. High precision pressure measurement with a funnel

    International Nuclear Information System (INIS)

    Lopez-Arias, T; Gratton, L M; Oss, S

    2008-01-01

    A simple experimental device for high precision differential pressure measurements is presented. Its working mechanism recalls that of a hydraulic press, where pressure is supplied by insufflating air under a funnel. As an application, we measure air pressure inside a soap bubble. The soap bubble is inflated and connected to a funnel which is placed, upside down, in a container filled with distilled water, placed on a scale. Our method provides a theoretical precision for the pressure measurement of the order of 0.01 Pa. Beyond this, the advantage of this method relies on the simplicity of the materials used and on the opportunity to discuss, at an undergraduate level, basic concepts regarding all those phenomena in which low or very low differential pressures are relevant

  8. Usefulness of Models in Precision Nutrient Management

    DEFF Research Database (Denmark)

    Plauborg, Finn; Manevski, Kiril; Zhenjiang, Zhou

    characterize soil condition by mapping a variety of physical-chemical properties including salinity, water content, texture, bulk density. vis–NIR spectroscopy shows the potential for use directly for the characterisation of soil quality, or soil fertility as the spectra contain information on soil organic...... and mineral composition. Mapping of crop status and the spatial-temporal variability within fields with red-infrared reflection are used to support decision on split fertilisation and more precise dosing. The interpretation and use of these various data in precise nutrient management is not straightforward......, especially as the various soil and crop state variables or indicators are a result of several processes integrated over time. The present paper explore the possibility to use a physically based model to interpret the spatial variable data and if the model sensitivity to changes in input my lead to a valid...

  9. Advanced composite materials for precision segmented reflectors

    Science.gov (United States)

    Stein, Bland A.; Bowles, David E.

    1988-01-01

    The objective in the NASA Precision Segmented Reflector (PSR) project is to develop new composite material concepts for highly stable and durable reflectors with precision surfaces. The project focuses on alternate material concepts such as the development of new low coefficient of thermal expansion resins as matrices for graphite fiber reinforced composites, quartz fiber reinforced epoxies, and graphite reinforced glass. Low residual stress fabrication methods will be developed. When coupon specimens of these new material concepts have demonstrated the required surface accuracies and resistance to thermal distortion and microcracking, reflector panels will be fabricated and tested in simulated space environments. An important part of the program is the analytical modeling of environmental stability of these new composite materials concepts through constitutive equation development, modeling of microdamage in the composite matrix, and prediction of long term stability (including viscoelasticity). These analyses include both closed form and finite element solutions at the micro and macro levels.

  10. Precision wildlife monitoring using unmanned aerial vehicles

    Science.gov (United States)

    Hodgson, Jarrod C.; Baylis, Shane M.; Mott, Rowan; Herrod, Ashley; Clarke, Rohan H.

    2016-03-01

    Unmanned aerial vehicles (UAVs) represent a new frontier in environmental research. Their use has the potential to revolutionise the field if they prove capable of improving data quality or the ease with which data are collected beyond traditional methods. We apply UAV technology to wildlife monitoring in tropical and polar environments and demonstrate that UAV-derived counts of colony nesting birds are an order of magnitude more precise than traditional ground counts. The increased count precision afforded by UAVs, along with their ability to survey hard-to-reach populations and places, will likely drive many wildlife monitoring projects that rely on population counts to transition from traditional methods to UAV technology. Careful consideration will be required to ensure the coherence of historic data sets with new UAV-derived data and we propose a method for determining the number of duplicated (concurrent UAV and ground counts) sampling points needed to achieve data compatibility.

  11. Optimizing mouse models for precision cancer prevention.

    Science.gov (United States)

    Le Magnen, Clémentine; Dutta, Aditya; Abate-Shen, Cory

    2016-03-01

    As cancer has become increasingly prevalent, cancer prevention research has evolved towards placing a greater emphasis on reducing cancer deaths and minimizing the adverse consequences of having cancer. 'Precision cancer prevention' takes into account the collaboration of intrinsic and extrinsic factors in influencing cancer incidence and aggressiveness in the context of the individual, as well as recognizing that such knowledge can improve early detection and enable more accurate discrimination of cancerous lesions. However, mouse models, and particularly genetically engineered mouse (GEM) models, have yet to be fully integrated into prevention research. In this Opinion article, we discuss opportunities and challenges for precision mouse modelling, including the essential criteria of mouse models for prevention research, representative success stories and opportunities for more refined analyses in future studies.

  12. Precision measurements of the CKM angle gamma

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The level of CP-violation permitted within the Standard Model cannot account for the matter dominated universe in which we live. Within the Standard Model the CKM matrix, which describes the quark couplings, is expected to be unitary. By making precise measurements of the CKM matrix parameters new physics models can be constrained, or with sufficient precision the effects of physics beyond the standard model might become apparent. The CKM angle gamma is the least well known angle of the unitarity triangle. It is the only angle easily accessible at tree-level, and furthermore has almost no theoretical uncertainties. Therefore it provides an invaluable Standard Model benchmark against which other new physics sensitive tests of the CP-violation can be made. I will discuss recent measurements of gamma using the the Run 1 LHCb dataset, which improve our knowledge of this key parameter.

  13. Precision measurements with LPCTrap at GANIL

    Energy Technology Data Exchange (ETDEWEB)

    Liénard, E., E-mail: lienard@lpccaen.in2p3.fr; Ban, G. [LPC CAEN, ENSICAEN, Université de Caen, CNRS/IN2P3 (France); Couratin, C. [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Delahaye, P. [GANIL, CEA/DSM-CNRS/IN2P3 (France); Durand, D.; Fabian, X. [LPC CAEN, ENSICAEN, Université de Caen, CNRS/IN2P3 (France); Fabre, B. [CELIA, Université Bordeaux, CNRS, CEA (France); Fléchard, X. [LPC CAEN, ENSICAEN, Université de Caen, CNRS/IN2P3 (France); Finlay, P. [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Mauger, F. [LPC CAEN, ENSICAEN, Université de Caen, CNRS/IN2P3 (France); Méry, A. [CIMAP, CEA/CNRS/ENSICAEN, Université de Caen (France); Naviliat-Cuncic, O. [NSCL and Department of Physics and Astronomy, MSU (United States); Pons, B. [CELIA, Université Bordeaux, CNRS, CEA (France); Porobic, T. [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Quéméner, G. [LPC CAEN, ENSICAEN, Université de Caen, CNRS/IN2P3 (France); Severijns, N. [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium); Thomas, J. C. [GANIL, CEA/DSM-CNRS/IN2P3 (France); Velten, Ph. [Instituut voor Kern- en Stralingsfysica, KU Leuven (Belgium)

    2015-11-15

    The experimental achievements and the results obtained so far with the LPCTrap device installed at GANIL are presented. The apparatus is dedicated to the study of the weak interaction at low energy by means of precise measurements of the β − ν angular correlation parameter in nuclear β decays. So far, the data collected with three isotopes have enabled to determine, for the first time, the charge state distributions of the recoiling ions, induced by shakeoff process. The analysis is presently refined to deduce the correlation parameters, with the potential of improving both the constraint deduced at low energy on exotic tensor currents ({sup 6}He{sup 1+}) and the precision on the V{sub ud} element of the quark-mixing matrix ({sup 35}Ar{sup 1+} and {sup 19}Ne{sup 1+}) deduced from the mirror transitions dataset.

  14. Precision wildlife monitoring using unmanned aerial vehicles.

    Science.gov (United States)

    Hodgson, Jarrod C; Baylis, Shane M; Mott, Rowan; Herrod, Ashley; Clarke, Rohan H

    2016-03-17

    Unmanned aerial vehicles (UAVs) represent a new frontier in environmental research. Their use has the potential to revolutionise the field if they prove capable of improving data quality or the ease with which data are collected beyond traditional methods. We apply UAV technology to wildlife monitoring in tropical and polar environments and demonstrate that UAV-derived counts of colony nesting birds are an order of magnitude more precise than traditional ground counts. The increased count precision afforded by UAVs, along with their ability to survey hard-to-reach populations and places, will likely drive many wildlife monitoring projects that rely on population counts to transition from traditional methods to UAV technology. Careful consideration will be required to ensure the coherence of historic data sets with new UAV-derived data and we propose a method for determining the number of duplicated (concurrent UAV and ground counts) sampling points needed to achieve data compatibility.

  15. Electroweak Precision Tests with GigaZ

    CERN Document Server

    Heinemeyer, S

    2000-01-01

    By running the prospective high-energy e^+e^- collider TESLA in the GigaZ mode on the Z resonance, experiments can be performed on the basis of more than 10^9 Z events. This will allow the measurement of the effective electroweak mixing angle to an accuracy of \\delta sin^2(theta_W,eff) \\approx \\pm 10^-5. The W boson mass is likewise expected to be measurable with an error of \\delta M_W \\approx \\pm 6 MeV near the W^+W^ threshold. We review the electroweak precision tests that can be performed with these high precision measurements within the Standard Model (SM) and its minimal Supersymmetric extension (MSSM). The complementarity of direct measurements at a prospective linear e^+e^- collider and indirect constraints following from measurements performed at GigaZ is emphasized.

  16. Informatics for Precision Medicine and Healthcare.

    Science.gov (United States)

    Chen, Jiajia; Lin, Yuxin; Shen, Bairong

    2017-01-01

    The past decade has witnessed great advances in biomedical informatics. Biomedical informatics is an emerging field of healthcare that aims to translate the laboratory observation into clinical practice. Smart healthcare has also developed rapidly with ubiquitous sensor and communication technologies. It is able to capture the online patient-centric phenotypic variables, thus providing a rich information base for translational biomedical informatics. Biomedical informatics and smart healthcare represent two interrelated disciplines. On one hand, biomedical informatics translates the bench discoveries into bedside, and, on the other hand, it is reciprocally informed by clinical data generated from smart healthcare. In this chapter, we will introduce the major strategies and challenges in the application of biomedical informatics technology in precision medicine and healthcare. We highlight how the informatics technology will promote the precision medicine and therefore promise the improvement of healthcare.

  17. PROSPECT - A precision oscillation and spectrum experiment

    Science.gov (United States)

    Langford, T. J.; PROSPECT Collaboration

    2015-08-01

    Segmented antineutrino detectors placed near a compact research reactor provide an excellent opportunity to probe short-baseline neutrino oscillations and precisely measure the reactor antineutrino spectrum. Close proximity to a reactor combined with minimal overburden yield a high background environment that must be managed through shielding and detector technology. PROSPECT is a new experimental effort to detect reactor antineutrinos from the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory, managed by UT Battelle for the U.S. Department of Energy. The detector will use novel lithium-loaded liquid scintillator capable of neutron/gamma pulse shape discrimination and neutron capture tagging. These enhancements improve the ability to identify neutrino inverse-beta decays (IBD) and reject background events in analysis. Results from these efforts will be covered along with their implications for an oscillation search and a precision spectrum measurement.

  18. Precision Top-Quark Mass Measurements at CDF

    Energy Technology Data Exchange (ETDEWEB)

    Aaltonen, T.; /Helsinki Inst. of Phys.; Alvarez Gonzalez, B.; /Oviedo U. /Cantabria Inst. of Phys.; Amerio, S.; /INFN, Padua; Amidei, D.; /Michigan U.; Anastassov, A.; /Northwestern U. /Fermilab; Annovi, A.; /Frascati; Antos, J.; /Comenius U.; Apollinari, G.; /Fermilab; Appel, J.A.; /Fermilab; Arisawa, T.; /Waseda U.; Artikov, A.; /Dubna, JINR /Texas A-M

    2012-07-01

    We present a precision measurement of the top-quark mass using the full sample of Tevatron {radical}s = 1.96 TeV proton-antiproton collisions collected by the CDF II detector, corresponding to an integrated luminosity of 8.7 fb{sup -1}. Using a sample of t{bar t} candidate events decaying into the lepton+jets channel, we obtain distributions of the top-quark masses and the invariant mass of two jets from the W boson decays from data. We then compare these distributions to templates derived from signal and background samples to extract the top-quark mass and the energy scale of the calorimeter jets with in situ calibration. The likelihood fit of the templates from signal and background events to the data yields the single most-precise measurement of the top-quark mass, mtop = 172.85 {+-} 0.71 (stat) {+-} 0.85 (syst) GeV/c{sup 2}.

  19. Precision Timing with Silicon Sensors for Use in Calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Bornheim, A. [Caltech; Ronzhin, A. [Fermilab; Kim, H. [Chicago U.; Bolla, G. [Fermilab; Pena, C. [Caltech; Xie, S. [Caltech; Apresyan, A. [Caltech; Los, S. [Fermilab; Spiropulu, M. [Caltech; Ramberg, E. [Fermilab

    2017-11-27

    The high luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN is expected to provide instantaneous luminosities of 5 × 1034 cm-2 s-1. The high luminosities expected at the HL-LHC will be accompanied by a factor of 5 to 10 more pileup compared with LHC conditions in 2015, causing general confusion for particle identification and event reconstruction. Precision timing allows to extend calorimetric measurements into such a high density environment by subtracting the energy deposits from pileup interactions. Calorimeters employing silicon as the active component have recently become a popular choice for the HL- LHC and future collider experiments which face very high radiation environments. We present studies of basic calorimetric and precision timing measurements using a prototype composed of tungsten absorber and silicon sensor as the active medium. We show that for the bulk of electromagnetic showers induced by electrons in the range of 20 GeV to 30 GeV, we can achieve time resolutions better than 25 ps per single pad sensor.

  20. Precise muon drift tube detectors for high background rate conditions

    CERN Document Server

    Engl, Albert; Dünnweber, Wolfgang

    The muon spectrometer of the ATLAS-experiment at the Large H adron Collider consists of drift tube chambers, which provide the precise m easurement of trajec- tories of traversing muons. In order to determine the moment um of the muons with high precision, the measurement of the position of the m uon in a single tube has to be more accurate than σ ≤ 100 m. The large cross section of proton-proton-collisions and th e high luminosity of the accelerator cause relevant background of neutrons and γ s in the muon spectrome- ter. During the next decade a luminosity upgrade [1] to 5 10 34 cm − 2 s − 1 is planned, which will increase the background counting rates consider ably. In this context this work deals with the further development of the existing drift chamber tech- nology to provide the required accuracy of the position meas urement under high background conditions. Two approaches of improving the dri ft tube chambers are described: • In regions of moderate background rates a faster and more lin ear ...

  1. Advancing theranostics with tumor-targeting peptides for precision otolaryngology

    Directory of Open Access Journals (Sweden)

    Chadwick L. Wright

    2016-06-01

    Full Text Available Worldwide, about 600,000 head and neck squamous cell carcinoma (HNSCC are detected annually, many of which involve high risk human papilloma virus (HPV. Surgery is the primary and desired first treatment option. Following surgery, the existence of cancer cells at the surgical margin is strongly associated with eventual recurrence of cancer and a poor outcome. Despite improved surgical methods (robotics, microsurgery, endoscopic/laparoscopic, and external imaging, surgeons rely only on their vision and touch to locate tumors during surgery. Diagnostic imaging systems like computed tomography (CT, magnetic resonance imaging (MRI, single-photon emission computed tomography (SPECT and positron-emission tomography (PET are too large, slow and costly to use efficiently during most surgeries and, ultrasound imaging, while fast and portable, is not cancer specific. This purpose of this article is to review the fundamental technologies that will radically advance Precision Otolaryngology practices to the benefit of patients with HNSCC. In particular, this article will address the potential for tumor-targeting peptides to enable more precise diagnostic imaging while simultaneously advancing new therapeutic paradigms for next generation image-guided surgery, tumor-specific chemotherapeutic delivery and tumor-selective targeted radiotherapy (i.e., theranostic. Keywords: Squamous cell carcinoma, Peptide, Optical surgical navigation, Diagnostic imaging, Theranostic

  2. Precision top-quark mass measurement at CDF.

    Science.gov (United States)

    Aaltonen, T; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Appel, J A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Auerbach, B; Aurisano, A; Azfar, F; Badgett, W; Bae, T; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauce, M; Bedeschi, F; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Bisello, D; Bizjak, I; Bland, K R; Blumenfeld, B; Bocci, A; Bodek, A; Bortoletto, D; Boudreau, J; Boveia, A; Brigliadori, L; Bromberg, C; Brucken, E; Budagov, J; Budd, H S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Calamba, A; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chung, W H; Chung, Y S; Ciocci, M A; Clark, A; Clarke, C; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuevas, J; Culbertson, R; Dagenhart, D; d'Ascenzo, N; Datta, M; de Barbaro, P; Dell'Orso, M; Demortier, L; Deninno, M; Devoto, F; d'Errico, M; Di Canto, A; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, M; Dorigo, T; Ebina, K; Elagin, A; Eppig, A; Erbacher, R; Errede, S; Ershaidat, N; Eusebi, R; Farrington, S; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Funakoshi, Y; Furic, I; Gallinaro, M; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerchtein, E; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Ginsburg, C M; Giokaris, N; Giromini, P; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldin, D; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Grinstein, S; Grosso-Pilcher, C; Group, R C; Guimaraes da Costa, J; Hahn, S R; Halkiadakis, E; Hamaguchi, A; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Hewamanage, S; Hocker, A; Hopkins, W; Horn, D; Hou, S; Hughes, R E; Hurwitz, M; Husemann, U; Hussain, N; Hussein, M; Huston, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jindariani, S; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Karchin, P E; Kasmi, A; Kato, Y; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kim, Y J; Kimura, N; Kirby, M; Klimenko, S; Knoepfel, K; Kondo, K; Kong, D J; Konigsberg, J; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Kruse, M; Krutelyov, V; Kuhr, T; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; LeCompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leo, S; Leone, S; Lewis, J D; Limosani, A; Lin, C-J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, H; Liu, Q; Liu, T; Lockwitz, S; Loginov, A; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Madrak, R; Maeshima, K; Maestro, P; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Martínez, M; Mastrandrea, P; Matera, K; Mattson, M E; Mazzacane, A; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Mesropian, C; Miao, T; Mietlicki, D; Mitra, A; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Noh, S Y; Norniella, O; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Ortolan, L; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Paramonov, A A; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pilot, J; Pitts, K; Plager, C; Pondrom, L; Poprocki, S; Potamianos, K; Prokoshin, F; Pranko, A; Ptohos, F; Punzi, G; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Rescigno, M; Riddick, T; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Ruffini, F; Ruiz, A; Russ, J; Rusu, V; Safonov, A; Sakumoto, W K; Sakurai, Y; Santi, L; Sato, K; Saveliev, V; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Seidel, S; Seiya, Y; Semenov, A; Sforza, F; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shochet, M; Shreyber-Tecker, I; Simonenko, A; Sinervo, P; Sliwa, K; Smith, J R; Snider, F D; Soha, A; Sorin, V; Song, H; Squillacioti, P; Stancari, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Sudo, Y; Sukhanov, A

    2012-10-12

    We present a precision measurement of the top-quark mass using the full sample of Tevatron √s = 1.96 TeV proton-antiproton collisions collected by the CDF II detector, corresponding to an integrated luminosity of 8.7 fb(-1). Using a sample of tt¯ candidate events decaying into the lepton+jets channel, we obtain distributions of the top-quark masses and the invariant mass of two jets from the W boson decays from data. We then compare these distributions to templates derived from signal and background samples to extract the top-quark mass and the energy scale of the calorimeter jets with in situ calibration. The likelihood fit of the templates from signal and background events to the data yields the single most-precise measurement of the top-quark mass, M(top)=172.85±0.71(stat)±0.85(syst) GeV/c(2).

  3. Electroweak precision data and gravitino dark matter

    Indian Academy of Sciences (India)

    We analyze the precision observables in the context of the GDM, focusing on parameter combina- tions that fulfill 0.094 < ΩCDMh2 < 0.129 [7]. In order to simplify the analysis in a motivated manner, we .... m1/2 discussed above maps into an analogous preference for moderate tan β (see ref. [2]). It can be shown that, at the ...

  4. Precision Index in the Multivariate Context

    Czech Academy of Sciences Publication Activity Database

    Šiman, Miroslav

    2014-01-01

    Roč. 43, č. 2 (2014), s. 377-387 ISSN 0361-0926 R&D Projects: GA MŠk(CZ) 1M06047 Institutional support: RVO:67985556 Keywords : data depth * multivariate quantile * process capability index * precision index * regression quantile Subject RIV: BA - General Mathematics Impact factor: 0.274, year: 2014 http://library.utia.cas.cz/separaty/2014/SI/siman-0425059.pdf

  5. Nanotechnology: The new perspective in precision agriculture

    OpenAIRE

    Duhan, Joginder Singh; Kumar, Ravinder; Kumar, Naresh; Kaur, Pawan; Nehra, Kiran; Duhan, Surekha

    2017-01-01

    Nanotechnology is an interdisciplinary research field. In recent past efforts have been made to improve agricultural yield through exhaustive research in nanotechnology. The green revolution resulted in blind usage of pesticides and chemical fertilizers which caused loss of soil biodiversity and developed resistance against pathogens and pests as well. Nanoparticle-mediated material delivery to plants and advanced biosensors for precision farming are possible only by nanoparticles or nanochip...

  6. Precision Jet production for the LHC

    CERN Multimedia

    CERN. Geneva

    2017-01-01

    Jet production is one of the basic processes at the LHC with numerous uses for standard model and BSM phenomenology. Understanding this process with suitable precision has been a long-standing goal for the particle physics community. I will report on our recent calculation of the NNLO contribution to jet production using antenna subtraction and discuss what these results might mean for jet phenomenology in the near future.

  7. The precise temporal calibration of dinosaur origins

    OpenAIRE

    Marsicano, Claudia A.; Irmis, Randall B.; Mancuso, Adriana C.; Mundil, Roland; Chemale, Farid

    2015-01-01

    Many hypotheses have been put forth to explain the origin and early radiation of dinosaurs, but poor age constraints for constituent fossil assemblages make these scenarios difficult to test. Using precise radioisotopic ages, we demonstrate that the temporal gap between assemblages containing only dinosaur precursors and those with the first dinosaurs was 5–10 million years shorter than previously thought. Thus, these data suggest that the origin of dinosaurs was a relatively rapid evolutiona...

  8. High precision densimeter for heavy water analysis

    International Nuclear Information System (INIS)

    Hirean, I.; Pavelescu, M.; Balint, C.; David, C.

    1995-01-01

    A high precision densimeter for analysis of heavy water isotopic concentration is presented. The density is derived from the eigenfrequency of oscillation of a tube filled with the fluid to be measured. An increase in measurement accuracy was obtained by utilization of a Peltier electronic thermostat. This densimeter has numerous applications in chemical and petrochemical industry, in paper and sugar industry, in nuclear fuel reprocessing, as well as, in medical research. 1 Fig

  9. Hidden SUSY from precision gauge unification

    International Nuclear Information System (INIS)

    Krippendorf, Sven; Nilles, Hans Peter

    2013-06-01

    We revisit the implications of naturalness and gauge unification in the MSSM. We find that precision unification of the couplings in connection with a small μ parameter requires a highly compressed gaugino pattern as it is realized in mirage mediation. Due to the small mass difference between gluino and LSP, collider limits on the gluino mass are drastically relaxed. Without further assumptions, the relic density of the LSP is very close to the observed dark matter density due to coannihilation effects.

  10. 40 CFR 75.41 - Precision criteria.

    Science.gov (United States)

    2010-07-01

    ... available in the data set. s′x i = The standard deviation of the original data values, x′i defined by, EC01SE92.103 (Eq. 15) where, s″x i = The standard deviation of the LAG1 data values, x″i, defined by... monitoring system shall meet the statistical tests for precision in paragraph (c) of this section and the t...

  11. CMS-TOTEM Precision Proton Spectrometer

    CERN Document Server

    AUTHOR|(CDS)2071798; Arneodo, M; Avati, V; Baechler, J; Cartiglia, N; Deile, M; Gallinaro, M; Hollar, J; Lo Vetere, M; Oesterberg, K; Turini, N; Varela, J; Wright, D; CMS-TOTEM, Collaboration; CERN. Geneva. The LHC experiments Committee; LHCC

    2014-01-01

    This report describes the technical design and outlines the expected performance of the CMS-TOTEM Precision Proton Spectrometer (CT-PPS). CT-PPS adds precision proton tracking and timing detectors in the very forward region on both sides of CMS at about 200m from the IP to study central exclusive production (CEP) in proton-proton collisions. CEP provides a unique method to access a variety of physics topics at high luminosity LHC, such as new physics via anomalous production of $W$ and $Z$ boson pairs, high-$p_T$ jet production, and possibly the production of new resonances. The CT-PPS detector consists of a silicon tracking system to measure the position and direction of the protons, and a set of timing counters to measure their arrival time with a precision of the order of 10 ps. This in turn allows the reconstruction of the mass and momentum as well as of the $z$ coordinate of the primary vertex of the centrally produced system. The framework for the development and exploitation of CT-PPS is defined i...

  12. Surface characterization protocol for precision aspheric optics

    Science.gov (United States)

    Sarepaka, RamaGopal V.; Sakthibalan, Siva; Doodala, Somaiah; Panwar, Rakesh S.; Kotaria, Rajendra

    2017-10-01

    In Advanced Optical Instrumentation, Aspherics provide an effective performance alternative. The aspheric fabrication and surface metrology, followed by aspheric design are complementary iterative processes for Precision Aspheric development. As in fabrication, a holistic approach of aspheric surface characterization is adopted to evaluate actual surface error and to aim at the deliverance of aspheric optics with desired surface quality. Precision optical surfaces are characterized by profilometry or by interferometry. Aspheric profiles are characterized by contact profilometers, through linear surface scans to analyze their Form, Figure and Finish errors. One must ensure that, the surface characterization procedure does not add to the resident profile errors (generated during the aspheric surface fabrication). This presentation examines the errors introduced post-surface generation and during profilometry of aspheric profiles. This effort is to identify sources of errors and is to optimize the metrology process. The sources of error during profilometry may be due to: profilometer settings, work-piece placement on the profilometer stage, selection of zenith/nadir points of aspheric profiles, metrology protocols, clear aperture - diameter analysis, computational limitations of the profiler and the software issues etc. At OPTICA, a PGI 1200 FTS contact profilometer (Taylor-Hobson make) is used for this study. Precision Optics of various profiles are studied, with due attention to possible sources of errors during characterization, with multi-directional scan approach for uniformity and repeatability of error estimation. This study provides an insight of aspheric surface characterization and helps in optimal aspheric surface production methodology.

  13. Precision of different quantitative ultrasound densitometers

    Energy Technology Data Exchange (ETDEWEB)

    Pocock, N.A.; Harris, N.D.; Griffiths, M.R. [St Vincents Hospital, Sydney, NSW (Australia) Department of Nuclear Medicine and Bone Densitometry

    1998-06-01

    Full text: Quantitative ultrasound (QUS) of the calcaneus, which measures Speed of Sound (SOS) and Broadband ultrasound attenuation (BUA), is predictive of the risk of osteoporotic fracture. However, the utility of QUS for predicting fracture risk or for monitoring treatment efficacy depends on its precision and reliability. Published results and manufacturers data vary significantly due to differences in statistical methodology. We have assessed the precision of the current model of the Lunar Achilles and the McCue Cuba QUS densitometers; the most commonly used QUS machines in Australia. Twenty seven subjects had duplicate QUS measurements performed on the same day on both machines. These data were used to calculate the within pair standard deviation (SD) the co-efficient of variation, CV and the standardised co efficient of variation (sCV) which is corrected for the dynamic range. In addition, the co-efficient of reliability (R) was calculated as an index of reliability which is independent of the population mean value, or the dynamic range of the measurements. R ranges between 0 (for no reliability) to 1(for a perfect reliability). The results indicate that the precision of QUS is dependent on the dynamic range and the instrument. Furthermore, they suggest that while QUS is a useful predictor of fracture risk, at present it has limited clinical value in monitoring short term age-related bone loss of 1-2% per year 1 tab.

  14. Precision of different quantitative ultrasound densitometers

    International Nuclear Information System (INIS)

    Pocock, N.A.; Harris, N.D.; Griffiths, M.R.

    1998-01-01

    Full text: Quantitative ultrasound (QUS) of the calcaneus, which measures Speed of Sound (SOS) and Broadband ultrasound attenuation (BUA), is predictive of the risk of osteoporotic fracture. However, the utility of QUS for predicting fracture risk or for monitoring treatment efficacy depends on its precision and reliability. Published results and manufacturers data vary significantly due to differences in statistical methodology. We have assessed the precision of the current model of the Lunar Achilles and the McCue Cuba QUS densitometers; the most commonly used QUS machines in Australia. Twenty seven subjects had duplicate QUS measurements performed on the same day on both machines. These data were used to calculate the within pair standard deviation (SD) the co-efficient of variation, CV and the standardised co efficient of variation (sCV) which is corrected for the dynamic range. In addition, the co-efficient of reliability (R) was calculated as an index of reliability which is independent of the population mean value, or the dynamic range of the measurements. R ranges between 0 (for no reliability) to 1(for a perfect reliability). The results indicate that the precision of QUS is dependent on the dynamic range and the instrument. Furthermore, they suggest that while QUS is a useful predictor of fracture risk, at present it has limited clinical value in monitoring short term age-related bone loss of 1-2% per year

  15. Precision genome editing in the CRISPR era.

    Science.gov (United States)

    Salsman, Jayme; Dellaire, Graham

    2017-04-01

    With the introduction of precision genome editing using CRISPR-Cas9 technology, we have entered a new era of genetic engineering and gene therapy. With RNA-guided endonucleases, such as Cas9, it is possible to engineer DNA double strand breaks (DSB) at specific genomic loci. DSB repair by the error-prone non-homologous end-joining (NHEJ) pathway can disrupt a target gene by generating insertions and deletions. Alternatively, Cas9-mediated DSBs can be repaired by homology-directed repair (HDR) using an homologous DNA repair template, thus allowing precise gene editing by incorporating genetic changes into the repair template. HDR can introduce gene sequences for protein epitope tags, delete genes, make point mutations, or alter enhancer and promoter activities. In anticipation of adapting this technology for gene therapy in human somatic cells, much focus has been placed on increasing the fidelity of CRISPR-Cas9 and increasing HDR efficiency to improve precision genome editing. In this review, we will discuss applications of CRISPR technology for gene inactivation and genome editing with a focus on approaches to enhancing CRISPR-Cas9-mediated HDR for the generation of cell and animal models, and conclude with a discussion of recent advances and challenges towards the application of this technology for gene therapy in humans.

  16. Needs and challenges in precision wear measurement

    Energy Technology Data Exchange (ETDEWEB)

    Blau, P.J.

    1996-01-10

    Accurate, precise wear measurements are a key element in solving both current wear problems and in basic wear research. Applications range from assessing durability of micro-scale components to accurate screening of surface treatments and thin solid films. Need to distinguish small differences in wear tate presents formidable problems to those who are developing new materials and surface treatments. Methods for measuring wear in ASTM standard test methods are discussed. Errors in using alterate methods of wear measurement on the same test specimen are also described. Human judgemental factors are a concern in common methods for wear measurement, and an experiment involving measurement of a wear scar by ten different people is described. Precision in wear measurement is limited both by the capabilities of the measuring instruments and by the nonuniformity of the wear process. A method of measuring wear using nano-scale indentations is discussed. Current and future prospects for incorporating advanced, higher-precision wear measurement methods into standards are considered.

  17. Precise Documentation: The Key to Better Software

    Science.gov (United States)

    Parnas, David Lorge

    The prime cause of the sorry “state of the art” in software development is our failure to produce good design documentation. Poor documentation is the cause of many errors and reduces efficiency in every phase of a software product's development and use. Most software developers believe that “documentation” refers to a collection of wordy, unstructured, introductory descriptions, thousands of pages that nobody wanted to write and nobody trusts. In contrast, Engineers in more traditional disciplines think of precise blueprints, circuit diagrams, and mathematical specifications of component properties. Software developers do not know how to produce precise documents for software. Software developments also think that documentation is something written after the software has been developed. In other fields of Engineering much of the documentation is written before and during the development. It represents forethought not afterthought. Among the benefits of better documentation would be: easier reuse of old designs, better communication about requirements, more useful design reviews, easier integration of separately written modules, more effective code inspection, more effective testing, and more efficient corrections and improvements. This paper explains how to produce and use precise software documentation and illustrate the methods with several examples.

  18. A comparison of drive mechanisms for precision motion controlled stages

    Energy Technology Data Exchange (ETDEWEB)

    Buice, E S; Yang, H; Otten, D; Smith, S T; Hocken, R J; Trumper, D L; Seugling, R M

    2006-03-22

    This abstract presents a comparison of two drive mechanisms, a Rohlix{reg_sign} drive and a polymer nut drive, for precision motion controlled stages. A single-axis long-range stage with a 50 mm traverse combined with a short-range stage with a 16 {micro}m traverse at a operational bandwidth of 2.2 kHz were developed to evaluate the performance of the drives. The polymer nut and Rohlix{reg_sign} drives showed 4 nm RMS and 7 nm RMS positioning capabilities respectively, with traverses of 5 mm at a maximum velocity of 0.15 mm{sup -}s{sup -1} with the short range stage operating at a 2.2 kHz bandwidth. Further results will be presented in the subsequent sections.

  19. Old and new technologies provide dynamic precise positioning

    International Nuclear Information System (INIS)

    Dano, P.K.

    1987-01-01

    Vehicle's coordinates are available for both reporting and operator use utilizing passive survey techniques and equipments with excellent results thus freeing up and protecting the vehicle reporting transmitters. Use of spread spectrum radiolocation offers real-time extraction and correction of system biases eliminating fixed timing errors. An unlimited number of users may receive differential signals as well as system description data in such a manner as to facilitate complete ''blind'' entry into the system while attaining full operational capability. Utilizing a proprietary technique, the passive user obtains additional lines of position as well as calibration information while using the traditional number of reference stations. A single frequency could be used world-wide since ''networks'' are identified by code. Adjacent networks can be indicated to the receiver using the system description data thus facilitating network to network operation without operator intervention. Although the system accuracy is excellent for survey, the automation of dynamic precise positioning is most advantageous in vehicle location

  20. Should precise numerical dating overrule glacial geomorphology?

    Science.gov (United States)

    Winkler, Stefan

    2016-04-01

    Numerical age dating techniques, namely different types of terrestrial cosmogenic nuclide dating (TCND), have achieved an impressive progress in both laboratory precision and regional calibration models during the past few decades. It is now possible to apply precise TCND even to young landforms like Late Holocene moraines, a task seemed hardly achievable just about 15 years ago. An increasing number of studies provide very precise TCND ages for boulders from Late Holocene moraines enabling related reconstruction of glacier chronologies and the interpretation of these glacial landforms in a palaeoclimatological context. These studies may also solve previous controversies about different ages assigned to moraines obtained by different dating techniques, for example relative-age dating techniques or techniques combining relative-age dating with few fixed points derived from numerical age dating. There are a few cases, for example Mueller Glacier and nearby long debris-covered valley glacier in Aoraki/Mt.Cook National Park (Southern Alps, New Zealand), where the apparent "supremacy" of TCND-ages seem to overrule glacial geomorphological principles. Enabled by a comparatively high number of individual boulders precisely dated by TCND, moraine ridges on those glacier forelands have been primarily clustered on basis of these boulder ages rather than on their corresponding morphological position. To the extreme, segments of a particular moraine complex morphologically and sedimentologically proven to be formed during one event have become split and classified as two separate "moraines" on different parts of the glacier foreland. One ledge of another moraine complex contains 2 TCND-sampled boulders apparently representing two separate "moraines"-clusters of an age difference in the order of 1,500 years. Although recently criticism has been raised regarding the non-contested application of the arithmetic mean for calculation of TCND-ages for individual moraines, this

  1. Precise Point Positioning Using Triple GNSS Constellations in Various Modes

    Directory of Open Access Journals (Sweden)

    Akram Afifi

    2016-05-01

    Full Text Available This paper introduces a new dual-frequency precise point positioning (PPP model, which combines the observations from three different global navigation satellite system (GNSS constellations, namely GPS, Galileo, and BeiDou. Combining measurements from different GNSS systems introduces additional biases, including inter-system bias and hardware delays, which require rigorous modelling. Our model is based on the un-differenced and between-satellite single-difference (BSSD linear combinations. BSSD linear combination cancels out some receiver-related biases, including receiver clock error and non-zero initial phase bias of the receiver oscillator. Forming the BSSD linear combination requires a reference satellite, which can be selected from any of the GPS, Galileo, and BeiDou systems. In this paper three BSSD scenarios are tested; each considers a reference satellite from a different GNSS constellation. Natural Resources Canada’s GPSPace PPP software is modified to enable a combined GPS, Galileo, and BeiDou PPP solution and to handle the newly introduced biases. A total of four data sets collected at four different IGS stations are processed to verify the developed PPP model. Precise satellite orbit and clock products from the International GNSS Service Multi-GNSS Experiment (IGS-MGEX network are used to correct the GPS, Galileo, and BeiDou measurements in the post-processing PPP mode. A real-time PPP solution is also obtained, which is referred to as RT-PPP in the sequel, through the use of the IGS real-time service (RTS for satellite orbit and clock corrections. However, only GPS and Galileo observations are used for the RT-PPP solution, as the RTS-IGS satellite products are not presently available for BeiDou system. All post-processed and real-time PPP solutions are compared with the traditional un-differenced GPS-only counterparts. It is shown that combining the GPS, Galileo, and BeiDou observations in the post-processing mode improves the

  2. Precise Point Positioning Using Triple GNSS Constellations in Various Modes.

    Science.gov (United States)

    Afifi, Akram; El-Rabbany, Ahmed

    2016-05-28

    This paper introduces a new dual-frequency precise point positioning (PPP) model, which combines the observations from three different global navigation satellite system (GNSS) constellations, namely GPS, Galileo, and BeiDou. Combining measurements from different GNSS systems introduces additional biases, including inter-system bias and hardware delays, which require rigorous modelling. Our model is based on the un-differenced and between-satellite single-difference (BSSD) linear combinations. BSSD linear combination cancels out some receiver-related biases, including receiver clock error and non-zero initial phase bias of the receiver oscillator. Forming the BSSD linear combination requires a reference satellite, which can be selected from any of the GPS, Galileo, and BeiDou systems. In this paper three BSSD scenarios are tested; each considers a reference satellite from a different GNSS constellation. Natural Resources Canada's GPSPace PPP software is modified to enable a combined GPS, Galileo, and BeiDou PPP solution and to handle the newly introduced biases. A total of four data sets collected at four different IGS stations are processed to verify the developed PPP model. Precise satellite orbit and clock products from the International GNSS Service Multi-GNSS Experiment (IGS-MGEX) network are used to correct the GPS, Galileo, and BeiDou measurements in the post-processing PPP mode. A real-time PPP solution is also obtained, which is referred to as RT-PPP in the sequel, through the use of the IGS real-time service (RTS) for satellite orbit and clock corrections. However, only GPS and Galileo observations are used for the RT-PPP solution, as the RTS-IGS satellite products are not presently available for BeiDou system. All post-processed and real-time PPP solutions are compared with the traditional un-differenced GPS-only counterparts. It is shown that combining the GPS, Galileo, and BeiDou observations in the post-processing mode improves the PPP convergence

  3. Precision spectroscopy with a frequency-comb-calibrated solar spectrograph

    Science.gov (United States)

    Doerr, H.-P.

    2015-06-01

    The measurement of the velocity field of the plasma at the solar surface is a standard diagnostic tool in observational solar physics. Detailed information about the energy transport as well as on the stratification of temperature, pressure and magnetic fields in the solar atmosphere are encoded in Doppler shifts and in the precise shape of the spectral lines. The available instruments deliver data of excellent quality and precision. However, absolute wavelength calibration in solar spectroscopy was so far mostly limited to indirect methods and in general suffers from large systematic uncertainties of the order of 100 m/s. During the course of this thesis, a novel wavelength calibration system based on a laser frequency comb was deployed to the solar Vacuum Tower Telescope (VTT), Tenerife, with the goal of enabling highly accurate solar wavelength measurements at the level of 1 m/s on an absolute scale. The frequency comb was developed in a collaboration between the Kiepenheuer-Institute for Solar Physics, Freiburg, Germany and the Max Planck Institute for Quantum Optics, Garching, Germany. The efforts cumulated in the new prototype instrument LARS (Lars is an Absolute Reference Spectrograph) for solar precision spectroscopy which is in preliminary scientific operation since~2013. The instrument is based on the high-resolution echelle spectrograph of the VTT for which feed optics based on single-mode optical fibres were developed for this project. The setup routinely achieves an absolute calibration accuracy of 60 cm/s and a repeatability of 2.5 cm/s. An unprecedented repeatability of only 0.32 cm/s could be demonstrated with a differential calibration scheme. In combination with the high spectral resolving power of the spectrograph of 7x10^5 and virtually absent internal scattered light, LARS provides a spectral purity and fidelity that previously was the domain of Fourier-transform spectrometers only. The instrument therefore provides unique capabilities for

  4. Sequential Linker Installation: Precise Placement of Functional Groups in Multivariate Metal-Organic Frameworks

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, S; Lu, WG; Chen, YP; Zhang, Q; Liu, TF; Feng, DW; Wang, X; Qin, JS; Zhou, HC

    2015-03-11

    A unique strategy, sequential linker installation (SLI), has been developed to construct multivariate MOFs with functional groups precisely positioned. PCN-700, a Zr-MOF with eight-connected Zr6O4(OH)(8)(H2O)(4) clusters, has been judiciously designed; the Zr-6 clusters in this MOF are arranged in such a fashion that, by replacement of terminal OH-/H2O ligands, subsequent insertion of linear dicarboxylate linkers is achieved. We demonstrate that linkers with distinct lengths and functionalities can be sequentially installed into PCN-700. Single-crystal to single-crystal transformation is realized so that the positions of the subsequently installed linkers are pinpointed via single-crystal X-ray diffraction analyses. This methodology provides a powerful tool to construct multivariate MOFs with precisely positioned functionalities in the desired proximity, which would otherwise be difficult to achieve.

  5. Precision Assessment of Near Real Time Precise Orbit Determination for Low Earth Orbiter

    Science.gov (United States)

    Choi, Jong-Yeoun; Lee, Sang-Jeong

    2011-03-01

    The precise orbit determination (POD) of low earth orbiter (LEO) has complied with its required positioning accuracy by the double-differencing of observations between International GNSS Service (IGS) and LEO to eliminate the common clock error of the global positioning system (GPS) satellites and receiver. Using this method, we also have achieved the 1 m positioning accuracy of Korea Multi-Purpose Satellite (KOMPSAT)-2. However double-differencing POD has huge load of processing the global network of lots of ground stations because LEO turns around the Earth with rapid velocity. And both the centimeter accuracy and the near real time (NRT) processing have been needed in the LEO POD applications--atmospheric sounding or urgent image processing--as well as the surveying. An alternative to differential GPS for high accuracy NRT POD is precise point positioning (PPP) to use measurements from one satellite receiver only, to replace the broadcast navigation message with precise post processed values from IGS, and to have phase measurements of dual frequency GPS receiver. PPP can obtain positioning accuracy comparable to that of differential positioning. KOMPSAT-5 has a precise dual frequency GPS flight receiver (integrated GPS and occultation receiver, IGOR) to satisfy the accuracy requirements of 20 cm positioning accuracy for highly precise synthetic aperture radar image processing and to collect GPS radio occultation measurements for atmospheric sounding. In this paper we obtained about 3-5 cm positioning accuracies using the real GPS data of the Gravity Recover and Climate Experiment (GRACE) satellites loaded the Blackjack receiver, a predecessor of IGOR. And it is important to reduce the latency of orbit determination processing in the NRT POD. This latency is determined as the volume of GPS measurements. Thus changing the sampling intervals, we show their latency to able to reduce without the precision degradation as the assessment of their precision.

  6. Advanced Electroactive Single Crystal and Polymer Actuator Concepts for Passive Optics, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes large stroke and high precision piezoelectric single crystal and electroactive polymer actuator concepts?HYBrid Actuation System (HYBAS)...

  7. Precision Subsampling System for Mars Surface Missions

    Science.gov (United States)

    Mahaffy, P. R.; Paulsen, G.; Mellerowicz, B.; ten Kate, I. L.; Conrad, P.; Corrigan, C. M.; Li, X.

    2012-01-01

    The ability to analyze heterogeneous rock samples at fine spatial scales would represent a powerful addition to our planetary in situ analytical toolbox. This is particularly true for Mars, where the signatures of past environments and, potentially, habitability are preserved in chemical and morphological variations across sedimentary layers and among mineral pr.ases in a given rock specimen. On Earth, microbial life often associates with surfaces at the interface of chemical nutrients, and ultimately retains sub-millimeter to millimeter-scale layer confinement in fossilization. On Mars, and possibly other bodies, trace chemical markers (elemental, organic/molecular, isotopic, chiral, etc.) and fine-scale morphological markers (e.g., micro-fossils) may he too subtle, degraded, or ambiguous to be detected, using miniaturized instrumentation, without some concentration or isolation. This is because (i) instrument sensitivity may not be high enough to detect trace markers in bulk averages; and (ii) instrument slectiviry may not be sufficient to distinguish such markers from interfering/counteracting signals from the bulk. Moreover from a fundamental chemostratigraphic perspective there would be a great benefit to assessing specific chemical and stable isotopic gradients, over millimeter-to-centimeter scales and beyond, with higher precision than currently possible in situ. We have developed a precision subsampling system (PSS) that addresses this need while remaining relatively flexible to a variety of instruments that may take advantage of the capability on future missions. The PSS is relevant to a number of possible lander/rover missions, especially Mars Sample Return. Our specific PSS prototype is undergoing testing under Mars ambient conditions, on a variety of natural analog rocks and rock drill cores, using a set of complementary flight-compatible measurement techniques. The system is available for testing with other contact instruments that may benefit from

  8. Batch fabrication of precision miniature permanent magnets

    Science.gov (United States)

    Christenson, Todd R.; Garino, Terry J.; Venturini, Eugene L.

    2002-01-01

    A new class of processes for fabrication of precision miniature rare earth permanent magnets is disclosed. Such magnets typically have sizes in the range 0.1 to 10 millimeters, and dimensional tolerances as small as one micron. Very large magnetic fields can be produced by such magnets, lending to their potential application in MEMS and related electromechanical applications, and in miniature millimeter-wave vacuum tubes. This abstract contains simplifications, and is supplied only for purposes of searching, not to limit or alter the scope or meaning of any claims herein.

  9. A precise technique for manufacturing correction coil

    International Nuclear Information System (INIS)

    Schieber, L.

    1992-01-01

    An automated method of manufacturing correction coils has been developed which provides a precise embodiment of the coil design. Numerically controlled machines have been developed to accurately position coil windings on the beam tube. Two types of machines have been built. One machine bonds the wire to a substrate which is wrapped around the beam tube after it is completed while the second machine bonds the wire directly to the beam tube. Both machines use the Multiwire reg-sign technique of bonding the wire to the substrate utilizing an ultrasonic stylus. These machines are being used to manufacture coils for both the SSC and RHIC

  10. Millisecond Pulsar Timing Precision with NICER

    Science.gov (United States)

    Deneva, Julia; Ray, Paul S.; Ransom, Scott; Wood, Kent S.; Kerr, Matthew T.; Lommen, Andrea; Arzoumanian, Zaven; Black, Kevin; Gendreau, Keith C.; Lewandowska, Natalia; Markwardt, Craig B.; Price, Samuel; Winternitz, Luke

    2018-01-01

    The Neutron Star Interior Composition Explorer (NICER) is an array of 56 X-ray detectors mounted on the outside of the International Space Station. It allows high-precision timing of millisecond pulsars (MSPs) without the pulse broadening effects due to dispersion and scattering by the interstellar medium that plague radio timing. We present initial timing results from four months of NICER data on the MSPs B1937+21, B1821-24, and J0218+4232, and compare them to simulations and theoretical models for X-ray times-of-arrival, and radio observations.

  11. Physicists of Ireland passion and precision

    CERN Document Server

    McCartney, Mark

    2003-01-01

    Demonstrating the strength of tradition in Ireland, Physicists of Ireland: Passion and Precision is a collection of essays on leading figures from the history of physics in Ireland. It includes physicists born outside of Ireland who carried out significant work in Ireland as well as those who had strong Irish roots but carried out their work outside of Ireland. The book is well illustrated with diagrams and photos of historical interest and rounded off with useful suggestions for further reading. It might come as a surprise to many that several leading English physicists are actually from Ireland.

  12. Lasers the power and precision of light

    CERN Document Server

    Diels, Jean-Claude

    2011-01-01

    ""Lasers"" are active ingredients of our modern life, but they are inconspicuous as they often go unnoticed. This intuitive introductory guide will tell you all you want to know about laser technologies in very diverse fields from nuclear and particle physics to medicine, astronomy and ultra-precise metrology. The book is coherently focused on fundamentals, and is aimed to stimulate intuition about present and future applications, while unveiling the halo of myths around lasers. Written by reputable laser experts who think that science should be entertaining, this useful reference relies on si

  13. Adoption of Precision farming in Denmark

    DEFF Research Database (Denmark)

    Pedersen, Søren Marcus; Fountas, S.; Blackmore, S.

    2003-01-01

    to demonstrate continuous yield improvements from Variable Rate Technology applications. The cost of gathering information, time consumption and incompatibility are barriers to adoption. Given teh uncertainty due to temporal variability, real time canopy management with N-sensors and weed detection is suggested......The adoption of precision farming (PF)in Denmark has been studied through two mail surveys, personal interviews and focus groups with farmers and other stakeholders. Farmers are in general optimistic about PF but it is difficult to verify the economic and environmental gains. It has been difficult...

  14. High-precision thorium RIMS for geochemistry

    International Nuclear Information System (INIS)

    Fearey, B.L.; Tissue, B.M.; Olivares, J.A.; Loge, G.W.; Murrell, M.T.; Miller, C.M.

    1992-01-01

    We present our latest results in the development of resonance ionization mass spectrometry (RIMS) using cw lasers to measure isotope ratios of importance in geochemistry and geochronology. The RIMS method provides a higher ionization efficiency than thermal ionization allowing analysis of smaller sample sizes, while maintaining equivalent internal precision. The bias introduced in 230/232 Th ratio measurements by the RIMS method when using narrow-band and broad-band lasers is discussed. Spectra of 239 Th, which can be used as an internal standard, are also presented

  15. Qualification of a precision pattern dispenser.

    Science.gov (United States)

    Van Ammel, Raf; Sobiech-Matura, Katarzyna; Wätjen, Uwe; Vercammen, Tom; Castelein, Pieter; Wuyts, Roel; Paul, Johan

    2018-04-01

    In order to automate sample preparation processes, a precision pattern dispenser was designed to reproducibly dispense radioactive solutions at pre-defined positions. It is composed of an automatic liquid sample handling unit coupled to an XYZ table. Qualification tests were conducted to evaluate the performance of the instrument and to assess the compliance with the requirements, in particular trueness (< 2%) and repeatability (< 1%). The instrument allows preparing sources in different source holders and on air filters, in a fast and accurate way. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  16. Autocalibration of high precision drift tubes

    International Nuclear Information System (INIS)

    Bacci, C.; Bini, C.; Ciapetti, G.; De Zorzi, G.; Gauzzi, P.; Lacava, F.; Nisati, A.; Pontecorvo, L.; Rosati, S.; Veneziano, S.; Cambiaghi, M.; Casellotti, G.; Conta, C.; Fraternali, M.; Lanza, A.; Livan, M.; Polesello, G.; Rimoldi, A.; Vercesi, V.

    1997-01-01

    We present the results on MDT (monitored drift tubes) autocalibration studies obtained from the analysis of the data collected in Summer 1995 on the H8B Muon Test Beam. In particular we studied the possibility of autocalibration of the MDT using four or three layers of tubes, and we compared the calibration obtained using a precise external tracker with the output of the autocalibration procedure. Results show the feasibility of autocalibration with four and three tubes and the good accuracy of the autocalibration procedure. (orig.)

  17. Precision and reproducibility in AMS radiocarbon measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Hotchkis, M.A.; Fink, D.; Hua, Q.; Jacobsen, G.E.; Lawson, E. M.; Smith, A.M.; Tuniz, C. [Australian Nuclear Science and Technology Organisation, Lucas Heights, NSW (Australia)

    1996-12-31

    Accelerator Mass Spectrometry (AMS) is a technique by which rare radioisotopes such as {sup 14}C can be measured at environmental levels with high efficiency. Instead of detecting radioactivity, which is very weak for long-lived environmental radioisotopes, atoms are counted directly. The sample is placed in an ion source, from which a negative ion beam of the atoms of interest is extracted, mass analysed, and injected into a tandem accelerator. After stripping to positive charge states in the accelerator HV terminal, the ions are further accelerated, analysed with magnetic and electrostatic devices and counted in a detector. An isotopic ratio is derived from the number of radioisotope atoms counted in a given time and the beam current of a stable isotope of the same element, measured after the accelerator. For radiocarbon, {sup 14}C/{sup 13}C ratios are usually measured, and the ratio of an unknown sample is compared to that of a standard. The achievable precision for such ratio measurements is limited primarily by {sup 14}C counting statistics and also by a variety of factors related to accelerator and ion source stability. At the ANTARES AMS facility at Lucas Heights Research Laboratories we are currently able to measure {sup 14}C with 0.5% precision. In the two years since becoming operational, more than 1000 {sup 14}C samples have been measured. Recent improvements in precision for {sup 14}C have been achieved with the commissioning of a 59 sample ion source. The measurement system, from sample changing to data acquisition, is under common computer control. These developments have allowed a new regime of automated multi-sample processing which has impacted both on the system throughput and the measurement precision. We have developed data evaluation methods at ANTARES which cross-check the self-consistency of the statistical analysis of our data. Rigorous data evaluation is invaluable in assessing the true reproducibility of the measurement system and aids in

  18. The precision of visual working memory is set by allocation of a shared resource

    OpenAIRE

    Bays, Paul M; Catalao, Raquel F G; Husain, Masud

    2009-01-01

    The mechanisms underlying visual working memory have recently become controversial. One account proposes a small number of memory ‘slots’, each capable of storing a single visual object with fixed precision. A contrary view holds that working memory is a shared resource, with no upper limit on the number of items stored; instead, the more items that are held in memory, the less precisely each can be recalled. Recent findings from a color report task have been taken as crucial new evidence in ...

  19. Double resonance calibration of g factor standards: Carbon fibers as a high precision standard

    Science.gov (United States)

    Herb, Konstantin; Tschaggelar, Rene; Denninger, Gert; Jeschke, Gunnar

    2018-04-01

    The g factor of paramagnetic defects in commercial high performance carbon fibers was determined by a double resonance experiment based on the Overhauser shift due to hyperfine coupled protons. Our carbon fibers exhibit a single, narrow and perfectly Lorentzian shaped ESR line and a g factor slightly higher than gfree with g = 2.002644 =gfree · (1 + 162ppm) with a relative uncertainty of 15ppm . This precisely known g factor and their inertness qualify them as a high precision g factor standard for general purposes. The double resonance experiment for calibration is applicable to other potential standards with a hyperfine interaction averaged by a process with very short correlation time.

  20. Determination of the seed geometry of cup plant as requirement for precision seeding

    Directory of Open Access Journals (Sweden)

    Andreas Schäfer

    2017-05-01

    Full Text Available In search of economically and ecologically interesting alternatives and additions to maize, currently the predominantly used biogas substrate, cup plant (Silphium perfoliatum L. has been found as a promising plant species. The perennial composite, which is located in North America, can be established by modified conventional seeders. Due to a long flowering period and different geographic origins of the plant material, seeds of different sizes and shapes can be found in the seed batch, which makes a precise singling of the seeds difficult. For the quantification of the geometric parameters the seeds were recorded and measured. The results of these researches were used to optimize the seeding in precision seeders.

  1. A precise measurement of the top quark mass

    Energy Technology Data Exchange (ETDEWEB)

    Mohr, Brian N. [Univ. of California, Los Angeles, CA (United States)

    2007-04-01

    We present a measurement of the mass of the top quark using data from proton-antiproton collisions recorded at the CDF experiment in Run II of the Fermilab Tevatron. Events are selected from the single lepton plus jets final state (t$\\bar{t}$ → W+bW-$\\bar{b}$ → ℓvbq$\\bar{q}$'$\\bar{b}$). The top quark mass is extracted using a calculation of the probability density for a t$\\bar{t}$ final state to resemble a data event. This probability density is a function of both top quark mass and energy scale of calorimeter jets, constrained in situ with the hadronic W boson mass. Using 167 events observed in 955 pb-1 integrated luminosity, we achieve the single most precise measurement of top quark mass to date of 170.8 ± 2.2 (stat.) ± 1.4 (syst.) GeV/c2, where the quoted statistical uncertainty includes uncertainty from the determination of the jet energy scale.

  2. Fabrication for precision mechanisms. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1980-03-01

    The fabrication of components and assemblies for miniature precision mechanisms provides a variety of exacting manufacturing challenges. Size alone makes many parts hard to pick up, handle, measure, and install. This same small size causes more distortion or bending during machining, assembly, and welding. Some parts even float on the cleaning and deburring solutions. Tools break easily in very small holes, and surface finishes play an important role in part operation. Twenty-five manufacturing operations were studied to improve the precision of existing machining and assembly techniques. The study included the machining of metals and plastics using techniques new to the manufacture of miniature switches, timers, and actuators. Drilling, tapping, and press-fitting miniature features were evaluated. Fixturing and handling techniques, friction reduction, and the forming of ceramic parts were also studied. Many of the new approaches from this study have been incorporated into existing processes and further refined. Detailed observations have been reported in 33 other Bendix reports and the highlights of those observations are summarized in this study.

  3. The precision of ophthalmic biometry using calipers

    Science.gov (United States)

    Mohamed, Ashik; Nankivil, Derek; Pesala, Veerendranath; Taneja, Mukesh

    2013-01-01

    Objective The purpose of the study is to determine the precision of whole globe and cornea measurements acquired using calipers, and to quantify the intraoperator and interoperator variance. Design Experimental study. Participants Ten human donor eyes. Methods Ten human eyes (donor age, 16–54 years) were obtained between 18.5 and 66.5 hours postmortem. The horizontal and vertical diameters and the anteroposterior length of the globe were measured using a digital Vernier caliper. The horizontal and vertical diameters of the cornea were measured using both a digital Vernier caliper and a Castroviejo caliper. The measurements were performed by 3 operators with 5 repeat measurements for each dimension. Results No significant differences were observed between measurements of globe anteroposterior length, horizontal diameter, and vertical diameter. Horizontal corneal diameter was greater than vertical diameter with all instruments and all operators. Variability of either instrument did not change with measurement object scale, and was similar across all operators. No significant differences were observed between the variabilities of the 2 devices. The mean intraoperator SD was 0.127 ± 0.023 mm with the digital caliper and 0.094 ± 0.056 mm with the Castroviejo caliper. Conclusions The precision of commercially available calipers in ophthalmic biometry measurements is limited to approximately 0.1 mm. PMID:24314412

  4. Precision neutron polarimetry for neutron beta decay

    Energy Technology Data Exchange (ETDEWEB)

    Penttila, S. I. (Seppo I.); Bowman, J. D. (J. David)

    2004-01-01

    The abBA collaboration is developing a new type of field-expansion spectrometer for measurement of the three correlation coefficients a, A, and B and shape parameter b. The measurement of A and B requires precision neutron polarimetry. We will polarize a pulsed cold neutron beam from SNS using a {sup 3}He neutron spin filter. The well-known polarizing cross section for n-{sup 3}He has 1/v dependence, which is used to determine the absolute beam polarization through a time-of-flight (TOF) measurement. We show that measuring the TOF dependence of A and B, the coefficients and the neutron polarization can be determined with small loss of statistical precision and negligible systematic error. We conclude that it is possible to determine the neutron polarization averaged over a run in the neutron beta decay experiment to better than 10{sup -3}. We discuss various sources of systematic uncertainties in the measurement of A and B and conclude that they are less than 10{sup -4}.

  5. Golden Jubilee photos: Precision is their motto

    CERN Multimedia

    2004-01-01

    At the beginning of the 1980s, CERN embarked on the enormous Large Electron-Positron Collider construction project. The excavation of the 27-kilometre LEP tunnel was a huge technical challenge. The tunnel-boring machines excavated the tunnel in 3.3 km octants and had to be operated with extraordinary precision to ensure that they reached their destination - the bottom of the next vertical shaft - precisely on target. The tunnel was excavated before high-performance instruments were developed for the construction of the Channel Tunnel. As no firms were willing to perform the surveying work, CERN's own surveyors, with experience from the SPS behind them, took up the challenge. At the surface, the surveyors established the world's most accurate geodetic network, performing measurements to an accuracy of 10-7, or 1mm per 10 km, using the Terrameter (see photo). The excavation of the tunnel was completed in 1988 and the finished tunnel's trajectory was found to diverge from the theoretical value specified by the...

  6. Precise positioning of patients for radiation therapy

    International Nuclear Information System (INIS)

    Verhey, L.J.; Goitein, M.; McNulty, P.; Munzenrider, J.E.; Suit, H.D.

    1982-01-01

    A number of immobilization schemes which permit precise daily positioning of patients for radiation therapy are discussed. Pretreatment and post-treatment radiographs have been taken with the patient in the treatment position and analyzed to determine the amount of intratreatment movement. Studies of patients in the supine, seated and decubitus positions indicate mean movements of less than 1 mm with a standard deviation of less than 1 mm. Patients immobilized in the seated position with a bite block and a mask have a mean movement of about 0.5 mm +/- 0.3 mm (s.d.), and patients immobilized in the supine position with their necks hyperextended for submental therapy evidence a mean movement of about 1.4 mm +/- 0.9 mm (s.d.). With the exception of those used for the decubitus position, the immobilization devices are simply fabricated out of thermoplastic casting materials readily available from orthopedic supply houses. A study of day-to-day reproducibility of patient position using laser alignment and pretreatment radiographs for final verification of position indicates that the initial laser alignment can be used to position a patient within 2.2 mm +/- 1.4 mm (s.d.) of the intended position. These results indicate that rigid immobilization devices can improve the precision of radiotherapy, which would be advantageous with respect to both tumor and normal tissue coverage in certain situations

  7. Soviet precision timekeeping research and technology

    International Nuclear Information System (INIS)

    Vessot, R.F.C.; Allan, D.W.; Crampton, S.J.B.; Cutler, L.S.; Kern, R.H.; McCoubrey, A.O.; White, J.D.

    1991-08-01

    This report is the result of a study of Soviet progress in precision timekeeping research and timekeeping capability during the last two decades. The study was conducted by a panel of seven US scientists who have expertise in timekeeping, frequency control, time dissemination, and the direct applications of these disciplines to scientific investigation. The following topics are addressed in this report: generation of time by atomic clocks at the present level of their technology, new and emerging technologies related to atomic clocks, time and frequency transfer technology, statistical processes involving metrological applications of time and frequency, applications of precise time and frequency to scientific investigations, supporting timekeeping technology, and a comparison of Soviet research efforts with those of the United States and the West. The number of Soviet professionals working in this field is roughly 10 times that in the United States. The Soviet Union has facilities for large-scale production of frequency standards and has concentrated its efforts on developing and producing rubidium gas cell devices (relatively compact, low-cost frequency standards of modest accuracy and stability) and atomic hydrogen masers (relatively large, high-cost standards of modest accuracy and high stability). 203 refs., 45 figs., 9 tabs

  8. Spiking Neural Network in Precision Agriculture

    Directory of Open Access Journals (Sweden)

    Nadia Adnan Shiltagh

    2015-07-01

    Full Text Available In this paper, precision agriculture system is introduced based on Wireless Sensor Network (WSN. Soil moisture considered one of environment factors that effect on crop. The period of irrigation must be monitored. Neural network capable of learning the behavior of the agricultural soil in absence of mathematical model. This paper introduced modified type of neural network that is known as Spiking Neural Network (SNN. In this work, the precision agriculture system is modeled, contains two SNNs which have been identified off-line based on logged data, one of these SNNs represents the monitor that located at sink where the period of irrigation is calculated and the other represents the soil. In addition, to reduce power consumption of sensor nodes Modified Chain-Cluster based Mixed (MCCM routing algorithm is used. According to MCCM, the sensors will send their packets that are less than threshold moisture level to the sink. The SNN with Modified Spike-Prop (MSP training algorithm is capable of identifying soil, irrigation periods and monitoring the soil moisture level, this means that SNN has the ability to be an identifier and monitor. By applying this system the particular agriculture area reaches to the desired moisture level.

  9. The precise temporal calibration of dinosaur origins.

    Science.gov (United States)

    Marsicano, Claudia A; Irmis, Randall B; Mancuso, Adriana C; Mundil, Roland; Chemale, Farid

    2016-01-19

    Dinosaurs have been major components of ecosystems for over 200 million years. Although different macroevolutionary scenarios exist to explain the Triassic origin and subsequent rise to dominance of dinosaurs and their closest relatives (dinosauromorphs), all lack critical support from a precise biostratigraphically independent temporal framework. The absence of robust geochronologic age control for comparing alternative scenarios makes it impossible to determine if observed faunal differences vary across time, space, or a combination of both. To better constrain the origin of dinosaurs, we produced radioisotopic ages for the Argentinian Chañares Formation, which preserves a quintessential assemblage of dinosaurian precursors (early dinosauromorphs) just before the first dinosaurs. Our new high-precision chemical abrasion thermal ionization mass spectrometry (CA-TIMS) U-Pb zircon ages reveal that the assemblage is early Carnian (early Late Triassic), 5- to 10-Ma younger than previously thought. Combined with other geochronologic data from the same basin, we constrain the rate of dinosaur origins, demonstrating their relatively rapid origin in a less than 5-Ma interval, thus halving the temporal gap between assemblages containing only dinosaur precursors and those with early dinosaurs. After their origin, dinosaurs only gradually dominated mid- to high-latitude terrestrial ecosystems millions of years later, closer to the Triassic-Jurassic boundary.

  10. Human genomics projects and precision medicine.

    Science.gov (United States)

    Carrasco-Ramiro, F; Peiró-Pastor, R; Aguado, B

    2017-09-01

    The completion of the Human Genome Project (HGP) in 2001 opened the floodgates to a deeper understanding of medicine. There are dozens of HGP-like projects which involve from a few tens to several million genomes currently in progress, which vary from having specialized goals or a more general approach. However, data generation, storage, management and analysis in public and private cloud computing platforms have raised concerns about privacy and security. The knowledge gained from further research has changed the field of genomics and is now slowly permeating into clinical medicine. The new precision (personalized) medicine, where genome sequencing and data analysis are essential components, allows tailored diagnosis and treatment according to the information from the patient's own genome and specific environmental factors. P4 (predictive, preventive, personalized and participatory) medicine is introducing new concepts, challenges and opportunities. This review summarizes current sequencing technologies, concentrates on ongoing human genomics projects, and provides some examples in which precision medicine has already demonstrated clinical impact in diagnosis and/or treatment.

  11. High-precision spectroscopy of antiprotonic helium

    CERN Document Server

    Widmann, E

    2001-01-01

    We present first results of laser and microwave spectroscopy experiments of antiprotonic helium performed at the new Antiproton Decelerator (AD) at CERN. Extending a series of previous measurements done at the Low Energy Antiproton Ring (LEAR) of CERN, several laser- induced transitions of the antiproton in the exotic three-body system He/sup 2+/-e/sup -/-p could be determined with a precision down to 1.3*10/sup -7/. This constitutes an improvement of a factor 3 over previous measurements, and allows to test accurate three-body calculations of this system that include QED corrections. The observed agreement on the same level can be used to infer CPT limits on the antiproton charge and mass. Furthermore, a first indication of a resonance signal of a two-laser microwave triple experiment to measure the hyperfine splitting of antiprotonic helium could been observed. Such a measurement has the potential to determine the antiproton magnetic moment to a higher precision that it is known today. (19 refs).

  12. Precision Astronomy with Imperfect Deep Depletion CCDs

    Science.gov (United States)

    Stubbs, Christopher; LSST Sensor Team; PanSTARRS Team

    2014-01-01

    While thick CCDs do provide definite advantages in terms of increased quantum efficiency at wavelengths 700 nmlateral electrical fields within the detector, that produce charge transport anomalies that have been previously misinterpreted as quantum efficiency variations. Performing simplistic flat-fielding therefore introduces systematic errors in the image processing pipeline. One measurement challenge we face is devising a combination of calibration methods and algorithms that can distinguish genuine quantum efficiency variations from charge transport effects. These device imperfections also confront spectroscopic applications, such as line centroid determination for precision radial velocity studies. Given the scientific benefits of improving both the precision and accuracy of astronomical measurements, we need to identify, characterize, and overcome these various detector artifacts. In retrospect, many of the detector features first identified in thick CCDs also afflict measurements made with more traditional CCD detectors, albeit often at a reduced level since the photocharge is subject to the perturbing influence of lateral electric fields for a shorter time interval. I provide a qualitative overview of the physical effects we think are responsible for the observed device properties, and provide some perspective for the work that lies ahead.

  13. Software for precise tracking of cell proliferation

    International Nuclear Information System (INIS)

    Kurokawa, Hiroshi; Noda, Hisayori; Sugiyama, Mayu; Sakaue-Sawano, Asako; Fukami, Kiyoko; Miyawaki, Atsushi

    2012-01-01

    Highlights: ► We developed software for analyzing cultured cells that divide as well as migrate. ► The active contour model (Snakes) was used as the core algorithm. ► The time backward analysis was also used for efficient detection of cell division. ► With user-interactive correction functions, the software enables precise tracking. ► The software was successfully applied to cells with fluorescently-labeled nuclei. -- Abstract: We have developed a multi-target cell tracking program TADOR, which we applied to a series of fluorescence images. TADOR is based on an active contour model that is modified in order to be free of the problem of locally optimal solutions, and thus is resistant to signal fluctuation and morphological changes. Due to adoption of backward tracing and addition of user-interactive correction functions, TADOR is used in an off-line and semi-automated mode, but enables precise tracking of cell division. By applying TADOR to the analysis of cultured cells whose nuclei had been fluorescently labeled, we tracked cell division and cell-cycle progression on coverslips over an extended period of time.

  14. The precise temporal calibration of dinosaur origins

    Science.gov (United States)

    Marsicano, Claudia A.; Irmis, Randall B.; Mancuso, Adriana C.; Mundil, Roland; Chemale, Farid

    2016-01-01

    Dinosaurs have been major components of ecosystems for over 200 million years. Although different macroevolutionary scenarios exist to explain the Triassic origin and subsequent rise to dominance of dinosaurs and their closest relatives (dinosauromorphs), all lack critical support from a precise biostratigraphically independent temporal framework. The absence of robust geochronologic age control for comparing alternative scenarios makes it impossible to determine if observed faunal differences vary across time, space, or a combination of both. To better constrain the origin of dinosaurs, we produced radioisotopic ages for the Argentinian Chañares Formation, which preserves a quintessential assemblage of dinosaurian precursors (early dinosauromorphs) just before the first dinosaurs. Our new high-precision chemical abrasion thermal ionization mass spectrometry (CA-TIMS) U-Pb zircon ages reveal that the assemblage is early Carnian (early Late Triassic), 5- to 10-Ma younger than previously thought. Combined with other geochronologic data from the same basin, we constrain the rate of dinosaur origins, demonstrating their relatively rapid origin in a less than 5-Ma interval, thus halving the temporal gap between assemblages containing only dinosaur precursors and those with early dinosaurs. After their origin, dinosaurs only gradually dominated mid- to high-latitude terrestrial ecosystems millions of years later, closer to the Triassic-Jurassic boundary.

  15. Precision neutron polarimetry for neutron beta decay

    International Nuclear Information System (INIS)

    Penttila, S.I.; Bowman, J.D.

    2004-01-01

    The abBA collaboration is developing a new type of field-expansion spectrometer for measurement of the three correlation coefficients a, A, and B and shape parameter b. The measurement of A and B requires precision neutron polarimetry. We will polarize a pulsed cold neutron beam from SNS using a 3 He neutron spin filter. The well-known polarizing cross section for n- 3 He has 1/v dependence, which is used to determine the absolute beam polarization through a time-of-flight (TOF) measurement. We show that measuring the TOF dependence of A and B, the coefficients and the neutron polarization can be determined with small loss of statistical precision and negligible systematic error. We conclude that it is possible to determine the neutron polarization averaged over a run in the neutron beta decay experiment to better than 10 -3 . We discuss various sources of systematic uncertainties in the measurement of A and B and conclude that they are less than 10 -4 .

  16. Towards High Productivity in Precision Grinding

    Directory of Open Access Journals (Sweden)

    W. Brian Rowe

    2018-04-01

    Full Text Available Over the last century, substantial advances have been made, based on improved understanding of the requirements of grinding processes, machines, control systems, materials, abrasives, wheel preparation, coolants, lubricants, and coolant delivery. This paper reviews a selection of areas in which the application of scientific principles and engineering ingenuity has led to the development of new grinding processes, abrasives, tools, machines, and systems. Topics feature a selection of areas where relationships between scientific principles and new techniques are yielding improved productivity and better quality. These examples point towards further advances that can fruitfully be pursued. Applications in modern grinding technology range from high-precision kinematics for grinding very large lenses and reflectors through to medium size grinding machine processes and further down to grinding very small components used in micro electro-mechanical systems (MEMS devices. The importance of material issues is emphasized for the range of conventional engineering steels, through to aerospace materials, ceramics, and composites. It is suggested that future advances in productivity will include the wider application of artificial intelligence and robotics to improve precision, process efficiency, and features required to integrate grinding processes into wider manufacturing systems.

  17. Soviet precision timekeeping research and technology

    Energy Technology Data Exchange (ETDEWEB)

    Vessot, R.F.C.; Allan, D.W.; Crampton, S.J.B.; Cutler, L.S.; Kern, R.H.; McCoubrey, A.O.; White, J.D.

    1991-08-01

    This report is the result of a study of Soviet progress in precision timekeeping research and timekeeping capability during the last two decades. The study was conducted by a panel of seven US scientists who have expertise in timekeeping, frequency control, time dissemination, and the direct applications of these disciplines to scientific investigation. The following topics are addressed in this report: generation of time by atomic clocks at the present level of their technology, new and emerging technologies related to atomic clocks, time and frequency transfer technology, statistical processes involving metrological applications of time and frequency, applications of precise time and frequency to scientific investigations, supporting timekeeping technology, and a comparison of Soviet research efforts with those of the United States and the West. The number of Soviet professionals working in this field is roughly 10 times that in the United States. The Soviet Union has facilities for large-scale production of frequency standards and has concentrated its efforts on developing and producing rubidium gas cell devices (relatively compact, low-cost frequency standards of modest accuracy and stability) and atomic hydrogen masers (relatively large, high-cost standards of modest accuracy and high stability). 203 refs., 45 figs., 9 tabs.

  18. Precision wildlife medicine: applications of the human-centred precision medicine revolution to species conservation.

    Science.gov (United States)

    Whilde, Jenny; Martindale, Mark Q; Duffy, David J

    2017-05-01

    The current species extinction crisis is being exacerbated by an increased rate of emergence of epizootic disease. Human-induced factors including habitat degradation, loss of biodiversity and wildlife population reductions resulting in reduced genetic variation are accelerating disease emergence. Novel, efficient and effective approaches are required to combat these epizootic events. Here, we present the case for the application of human precision medicine approaches to wildlife medicine in order to enhance species conservation efforts. We consider how the precision medicine revolution, coupled with the advances made in genomics, may provide a powerful and feasible approach to identifying and treating wildlife diseases in a targeted, effective and streamlined manner. A number of case studies of threatened species are presented which demonstrate the applicability of precision medicine to wildlife conservation, including sea turtles, amphibians and Tasmanian devils. These examples show how species conservation could be improved by using precision medicine techniques to determine novel treatments and management strategies for the specific medical conditions hampering efforts to restore population levels. Additionally, a precision medicine approach to wildlife health has in turn the potential to provide deeper insights into human health and the possibility of stemming and alleviating the impacts of zoonotic diseases. The integration of the currently emerging Precision Medicine Initiative with the concepts of EcoHealth (aiming for sustainable health of people, animals and ecosystems through transdisciplinary action research) and One Health (recognizing the intimate connection of humans, animal and ecosystem health and addressing a wide range of risks at the animal-human-ecosystem interface through a coordinated, collaborative, interdisciplinary approach) has great potential to deliver a deeper and broader interdisciplinary-based understanding of both wildlife and human

  19. Reliability of Pressure Ulcer Rates: How Precisely Can We Differentiate Among Hospital Units, and Does the Standard Signal‐Noise Reliability Measure Reflect This Precision?

    Science.gov (United States)

    Cramer, Emily

    2016-01-01

    Abstract Hospital performance reports often include rankings of unit pressure ulcer rates. Differentiating among units on the basis of quality requires reliable measurement. Our objectives were to describe and apply methods for assessing reliability of hospital‐acquired pressure ulcer rates and evaluate a standard signal‐noise reliability measure as an indicator of precision of differentiation among units. Quarterly pressure ulcer data from 8,199 critical care, step‐down, medical, surgical, and medical‐surgical nursing units from 1,299 US hospitals were analyzed. Using beta‐binomial models, we estimated between‐unit variability (signal) and within‐unit variability (noise) in annual unit pressure ulcer rates. Signal‐noise reliability was computed as the ratio of between‐unit variability to the total of between‐ and within‐unit variability. To assess precision of differentiation among units based on ranked pressure ulcer rates, we simulated data to estimate the probabilities of a unit's observed pressure ulcer rate rank in a given sample falling within five and ten percentiles of its true rank, and the probabilities of units with ulcer rates in the highest quartile and highest decile being identified as such. We assessed the signal‐noise measure as an indicator of differentiation precision by computing its correlations with these probabilities. Pressure ulcer rates based on a single year of quarterly or weekly prevalence surveys were too susceptible to noise to allow for precise differentiation among units, and signal‐noise reliability was a poor indicator of precision of differentiation. To ensure precise differentiation on the basis of true differences, alternative methods of assessing reliability should be applied to measures purported to differentiate among providers or units based on quality. © 2016 The Authors. Research in Nursing & Health published by Wiley Periodicals, Inc. PMID:27223598

  20. Nano-manipulation of single DNA molecules

    International Nuclear Information System (INIS)

    Hu Jun; Shanghai Jiaotong Univ., Shanghai; Lv Junhong; Wang Guohua; Wang Ying; Li Minqian; Zhang Yi; Li Bin; Li Haikuo; An Hongjie

    2004-01-01

    Nano-manipulation of single atoms and molecules is a critical technique in nanoscience and nanotechnology. This review paper will focus on the recent development of the manipulation of single DNA molecules based on atomic force microscopy (AFM). Precise manipulation has been realized including varied manipulating modes such as 'cutting', 'pushing', 'folding', 'kneading', 'picking up', 'dipping', etc. The cutting accuracy is dominated by the size of the AFM tip, which is usually 10 nm or less. Single DNA fragments can be cut and picked up and then amplified by single molecule PCR. Thus positioning isolation and sequencing can be performed. (authors)

  1. 19 Years of high precision timing of the millisecond pulsar J1713+0747

    Science.gov (United States)

    Zhu, Weiwei

    2013-03-01

    We report the analysis of a 19-year span of timing data on PSR J1713+0747 taken by the Arecibo and Green Bank telescopes. PSR J1713+0747 is one of the best high-timing-precision pulsars monitored by the NANOGrav project for the purpose of detecting gravitational waves. The timing precision of this pulsar can be regarded as the benchmark of NANOGrav timing instruments. We show the precision improvement achieved by multi-generation instruments including the Green Bank Ultimate Pulsar Processing Instrument (GUPPI) and its counterpart in Arecibo. The new timing solution we found improves the measurement of the pulsars mass, its orbital and geometric parameters, sets new limits on alternative gravitational theories, and may provide a high-quality single pulsar gravitational wave upper limit.

  2. An Ultra-low Frequency Modal Testing Suspension System for High Precision Air Pressure Control

    Directory of Open Access Journals (Sweden)

    Qiaoling YUAN

    2014-05-01

    Full Text Available As a resolution for air pressure control challenges in ultra-low frequency modal testing suspension systems, an incremental PID control algorithm with dead band is applied to achieve high-precision pressure control. We also develop a set of independent hardware and software systems for high-precision pressure control solutions. Taking control system versatility, scalability, reliability, and other aspects into considerations, a two-level communication employing Ethernet and CAN bus, is adopted to complete such tasks as data exchange between the IPC, the main board and the control board ,and the pressure control. Furthermore, we build a single set of ultra-low frequency modal testing suspension system and complete pressure control experiments, which achieve the desired results and thus confirm that the high-precision pressure control subsystem is reasonable and reliable.

  3. CubeSat Handling of Multisystem Precision Time Transfer (CHOMPTT)

    Data.gov (United States)

    National Aeronautics and Space Administration — The CubeSat Handling of Multisystem Precision Time Transfer (CHOMPTT) mission is a precision timing satellite equipped with atomic clocks synchronized with a ground...

  4. High precision relative position sensing system for formation flying spacecraft

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop and test an optical sensing system that provides high precision relative position sensing for formation flying spacecraft.  A high precision...

  5. Overcoming gaps and bottlenecks to advance precision agriculture

    Science.gov (United States)

    Maintaining a clear understanding of the technology gaps, knowledge needs, and training bottlenecks is required for improving adoption of precision agriculture. As an industry, precision agriculture embraces tools, methods, and practices that are constantly changing, requiring industry, education, a...

  6. Precision diamond grinding of ceramics and glass

    Energy Technology Data Exchange (ETDEWEB)

    Smith, S.; Paul, H.; Scattergood, R.O.

    1988-12-01

    A new research initiative will be undertaken to investigate the effect of machine parameters and material properties on precision diamond grinding of ceramics and glass. The critical grinding depth to initiate the plastic flow-to-brittle fracture regime will be directly measured using plunge-grind tests. This information will be correlated with machine parameters such as wheel bonding and diamond grain size. Multiaxis grinding tests will then be made to provide data more closely coupled with production technology. One important aspect of the material property studies involves measuring fracture toughness at the very short crack sizes commensurate with grinding damage. Short crack toughness value`s can be much less than the long-crack toughness values measured in conventional fracture tests.

  7. Precision Cosmology: The First Half Million Years

    Science.gov (United States)

    Jones, Bernard J. T.

    2017-06-01

    Cosmology seeks to characterise our Universe in terms of models based on well-understood and tested physics. Today we know our Universe with a precision that once would have been unthinkable. This book develops the entire mathematical, physical and statistical framework within which this has been achieved. It tells the story of how we arrive at our profound conclusions, starting from the early twentieth century and following developments up to the latest data analysis of big astronomical datasets. It provides an enlightening description of the mathematical, physical and statistical basis for understanding and interpreting the results of key space- and ground-based data. Subjects covered include general relativity, cosmological models, the inhomogeneous Universe, physics of the cosmic background radiation, and methods and results of data analysis. Extensive online supplementary notes, exercises, teaching materials, and exercises in Python make this the perfect companion for researchers, teachers and students in physics, mathematics, and astrophysics.

  8. Electroweak effective couplings for future precision experiments

    Energy Technology Data Exchange (ETDEWEB)

    Jegerlehner, F. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Humboldt-Universitaet, Berlin (Germany). Inst. fuer Physik

    2011-07-15

    The leading hadronic effects in electroweak theory derive from vacuum polarization which are non-perturbative hadronic contributions to the running of the gauge couplings, the electromagnetic {alpha}{sub em}(s) and the SU(2){sub L} coupling {alpha}{sub 2}(s). I report on my recent package alphaQED [1], which besides the effective fine structure constant {alpha}{sub em}(s) also allows for a fairly precise calculation of the SU(2){sub L} gauge coupling {alpha}{sub 2}(s). I will briefly review the role, future requirements and possibilities. Applied together with the Rhad package by Harlander and Steinhauser [2], the package allows to calculate all SM running couplings as well as running sin{sup 2} {theta} versions with state-of-the-art accuracy. (orig.)

  9. Sfermion precision measurements at a linear collider

    International Nuclear Information System (INIS)

    Freitas, A.; Ananthanarayan, B.; Bartl, A.; Blair, G.; Bloechinger, C.; Boos, E.; Brandenburg, A.; Datta, A.; Djouadi, A.; Fraas, H.; Guasch, J.; Hesselbach, S.; Hidaka, K.; Hollik, W.; Kernreiter, T.; Maniatis, M.; Manteuffel, A. von; Martyn, H.-U.; Miller, D.J.; Moortgat-Pick, G.; Muehlleitner, M.; Nauenberg, U.; Nowak, H.; Porod, W.; Sola, J.; Sopczak, A.; Stahl, A.; Weber, M.M.; Zerwas, P.M.

    2003-01-01

    At prospective e ± e - linear colliders, the large cross-sections and clean signals of scalar fermion production--in particular for the scalar leptons - allow very precise measurements of their masses and couplings and the determination of their quantum numbers. Various methods are proposed for extracting these parameters from the data at the sfermion thresholds and in the continuum. At the same time, NLO radiative corrections and non-zero width effects have been calculated in order to match the experimental accuracy. The substantial mixing expected in the third generation opens up additional opportunities. Techniques are presented for determining potential CP-violating phases and for extracting tan β from the stau sector, in particular at high values. The consequences of possible large mass differences in the stop and sbottom system are explored in dedicated analyses

  10. Precision cosmology the first half million years

    CERN Document Server

    Jones, Bernard J T

    2017-01-01

    Cosmology seeks to characterise our Universe in terms of models based on well-understood and tested physics. Today we know our Universe with a precision that once would have been unthinkable. This book develops the entire mathematical, physical and statistical framework within which this has been achieved. It tells the story of how we arrive at our profound conclusions, starting from the early twentieth century and following developments up to the latest data analysis of big astronomical datasets. It provides an enlightening description of the mathematical, physical and statistical basis for understanding and interpreting the results of key space- and ground-based data. Subjects covered include general relativity, cosmological models, the inhomogeneous Universe, physics of the cosmic background radiation, and methods and results of data analysis. Extensive online supplementary notes, exercises, teaching materials, and exercises in Python make this the perfect companion for researchers, teachers and students i...

  11. Electroweak Precision Measurements with the ATLAS Detector

    CERN Document Server

    Zhang, Zhiqing; The ATLAS collaboration

    2018-01-01

    With the high integrated luminosities recorded at the LHC and the very good understanding of the ATLAS detector, it is possible to measure electroweak observables to the highest precision. In this talk, we review the measurement of the W boson mass using data, collected at 7 TeV. Special focus is drawn on a discussion of the modeling uncertainties and the physics potential of the latest low-mu runs, recorded at a center of mass energy of 5 and 13 TeV at the end of 2017. The talk will also review the measurement of the triple differential Drell-Yan cross-section at 8 TeV, which can be used to extract the weak mixing angle. We conclude with a presentation of the tau polarization, measured in Z->tautau using 20.3/fb of proton proton collision data collected at a center of mass energy of 8 TeV.

  12. Precise individualized armature for ear reconstruction

    Science.gov (United States)

    Evenhouse, Raymond J.; Chen, Xiaoming

    1991-04-01

    The cosmetic result of an ear restored surgically or via prosthetics is dependent on the surgeon''s ability to carve a precise cartilage armature at the time of surgery or the prosthetist''s ability to sculpt in wax an exact duplicate of the patient''s " missing" ear. Introducing CAD/CAM technology into the process benefits the esthetic outcome of these procedures. By utilizing serial section information derived from CAT MRI or moulage techniques a mirrorimage of the patient''s " donor" ear is generated. The resulting earform data is then used for the design of a cartilage armature produced by multi-axis milling or to produce by stereolithography a model which serves as the basis for a prosthesis.

  13. Atomic physics precise measurements and ultracold matter

    CERN Document Server

    Inguscio, Massimo

    2013-01-01

    Atomic Physics provides an expert guide to two spectacular new landscapes in physics: precision measurements, which have been revolutionized by the advent of the optical frequency comb, and atomic physics, which has been revolutionized by laser cooling. These advances are not incremental but transformative: they have generated a consilience between atomic and many-body physics, precipitated an explosion of scientific and technological applications, opened new areas of research, and attracted a brilliant generation of younger scientists. The research is advancing so rapidly, the barrage of applications is so dazzling, that students can be bewildered. For both students and experienced scientists, this book provides an invaluable description of basic principles, experimental methods, and scientific applications.

  14. Externally Dispersed Interferometry for Precision Radial Velocimetry

    Energy Technology Data Exchange (ETDEWEB)

    Erskine, D J; Muterspaugh, M W; Edelstein, J; Lloyd, J; Herter, T; Feuerstein, W M; Muirhead, P; Wishnow, E

    2007-03-27

    Externally Dispersed Interferometry (EDI) is the series combination of a fixed-delay field-widened Michelson interferometer with a dispersive spectrograph. This combination boosts the spectrograph performance for both Doppler velocimetry and high resolution spectroscopy. The interferometer creates a periodic spectral comb that multiplies against the input spectrum to create moire fringes, which are recorded in combination with the regular spectrum. The moire pattern shifts in phase in response to a Doppler shift. Moire patterns are broader than the underlying spectral features and more easily survive spectrograph blurring and common distortions. Thus, the EDI technique allows lower resolution spectrographs having relaxed optical tolerances (and therefore higher throughput) to return high precision velocity measurements, which otherwise would be imprecise for the spectrograph alone.

  15. Precise documentation of well-structured programs

    Energy Technology Data Exchange (ETDEWEB)

    Parnas, D.L.; Madey, J.; Iglewski, M. [McMaster Univ., Hamilton, Ontario (Canada)

    1997-11-01

    This paper describes a new form of program documentation that is precise, systematic and readable. This documentation comprises a set of displays supplemented by a lexicon and an index. Each display presents a program fragment in such a way that its correctness can be examined without looking at any other display. Each display has three parts: (1) the specification of the program presented in the display, (2) the program itself, and (3) the specifications of programs invoked by this program. The displays are intended to be used by Software Engineers as a reference document during inspection and maintenance. This paper also introduces a specification technique that is a refinement of Mills functional approach to program documentation and verification; programs are specified and described in tabular form.

  16. Precise Multi-Spectral Dermatological Imaging

    DEFF Research Database (Denmark)

    Gomez, David Delgado; Carstensen, Jens Michael; Ersbøll, Bjarne Kjær

    2004-01-01

    In this work, an integrated imaging system to obtain accurate and reproducible multi-spectral dermatological images is proposed. The system is made up of an integrating sphere, light emitting diodes and a generic monochromatic camera. The system can collect up to 10 different spectral bands....... These spectral bands vary from ultraviolet to near infrared. The welldefined and diffuse illumination of the optically closed scene aims to avoid shadows and specular reflections. Furthermore, the system has been developed to guarantee the reproducibility of the collected images. This allows for comparative...... studies of time series of images. Two experiments are conducted to show the ability of the system to acquire highly precise and standardized multi-spectral images. The first experiment aims to show the capacity of the system to collect reproducible images. The second experiment demonstrates that the multi...

  17. PRECISE COSMIC RAYS MEASUREMENTS WITH PAMELA

    Directory of Open Access Journals (Sweden)

    A. Bruno

    2013-12-01

    Full Text Available The PAMELA experiment was launched on board the Resurs-DK1 satellite on June 15th 2006. The apparatus was designed to conduct precision studies of charged cosmic radiation over a wide energy range, from tens of MeV up to several hundred GeV, with unprecedented statistics. In five years of continuous data taking in space, PAMELA accurately measured the energy spectra of cosmic ray antiprotons and positrons, as well as protons, electrons and light nuclei, sometimes providing data in unexplored energetic regions. These important results have shed new light in several astrophysical fields like: an indirect search for Dark Matter, a search for cosmological antimatter (anti-Helium, and the validation of acceleration, transport and secondary production models of cosmic rays in the Galaxy. Some of the most important items of Solar and Magnetospheric physics were also investigated. Here we present the most recent results obtained by the PAMELA experiment.

  18. Intersecting circuits generate precisely patterned retinal waves.

    Science.gov (United States)

    Akrouh, Alejandro; Kerschensteiner, Daniel

    2013-07-24

    The developing retina generates spontaneous glutamatergic (stage III) waves of activity that sequentially recruit neighboring ganglion cells with opposite light responses (ON and OFF RGCs). This activity pattern is thought to help establish parallel ON and OFF pathways in downstream visual areas. The circuits that produce stage III waves and desynchronize ON and OFF RGC firing remain obscure. Using dual patch-clamp recordings, we find that ON and OFF RGCs receive sequential excitatory input from ON and OFF cone bipolar cells (CBCs), respectively. This input sequence is generated by crossover circuits, in which ON CBCs control glutamate release from OFF CBCs via diffusely stratified inhibitory amacrine cells. In addition, neighboring ON CBCs communicate directly and indirectly through lateral glutamatergic transmission and gap junctions, both of which are required for wave initiation and propagation. Thus, intersecting lateral excitatory and vertical inhibitory circuits give rise to precisely patterned stage III retinal waves. Copyright © 2013 Elsevier Inc. All rights reserved.

  19. Calculation of Weighted Geometric Dilution of Precision

    Directory of Open Access Journals (Sweden)

    Chien-Sheng Chen

    2013-01-01

    Full Text Available To achieve high accuracy in wireless positioning systems, both accurate measurements and good geometric relationship between the mobile device and the measurement units are required. Geometric dilution of precision (GDOP is widely used as a criterion for selecting measurement units, since it represents the geometric effect on the relationship between measurement error and positioning determination error. In the calculation of GDOP value, the maximum volume method does not necessarily guarantee the selection of the optimal four measurement units with minimum GDOP. The conventional matrix inversion method for GDOP calculation demands a large amount of operation and causes high power consumption. To select the subset of the most appropriate location measurement units which give the minimum positioning error, we need to consider not only the GDOP effect but also the error statistics property. In this paper, we employ the weighted GDOP (WGDOP, instead of GDOP, to select measurement units so as to improve the accuracy of location. The handheld global positioning system (GPS devices and mobile phones with GPS chips can merely provide limited calculation ability and power capacity. Therefore, it is very imperative to obtain WGDOP accurately and efficiently. This paper proposed two formations of WGDOP with less computation when four measurements are available for location purposes. The proposed formulae can reduce the computational complexity required for computing the matrix inversion. The simpler WGDOP formulae for both the 2D and the 3D location estimation, without inverting a matrix, can be applied not only to GPS but also to wireless sensor networks (WSN and cellular communication systems. Furthermore, the proposed formulae are able to provide precise solution of WGDOP calculation without incurring any approximation error.

  20. Precise Masses in the WASP-47 System

    Science.gov (United States)

    Vanderburg, Andrew; Becker, Juliette C.; Buchhave, Lars A.; Mortier, Annelies; Lopez, Eric; Malavolta, Luca; Haywood, Raphaëlle D.; Latham, David W.; Charbonneau, David; López-Morales, Mercedes; Adams, Fred C.; Bonomo, Aldo Stefano; Bouchy, François; Collier Cameron, Andrew; Cosentino, Rosario; Di Fabrizio, Luca; Dumusque, Xavier; Fiorenzano, Aldo; Harutyunyan, Avet; Johnson, John Asher; Lorenzi, Vania; Lovis, Christophe; Mayor, Michel; Micela, Giusi; Molinari, Emilio; Pedani, Marco; Pepe, Francesco; Piotto, Giampaolo; Phillips, David; Rice, Ken; Sasselov, Dimitar; Ségransan, Damien; Sozzetti, Alessandro; Udry, Stéphane; Watson, Chris

    2017-12-01

    We present precise radial velocity observations of WASP-47, a star known to host a hot Jupiter, a distant Jovian companion, and, uniquely, two additional transiting planets in short-period orbits: a super-Earth in a ≈19 hr orbit, and a Neptune in a ≈9 day orbit. We analyze our observations from the HARPS-N spectrograph along with previously published data to measure the most precise planet masses yet for this system. When combined with new stellar parameters and reanalyzed transit photometry, our mass measurements place strong constraints on the compositions of the two small planets. We find that, unlike most other ultra-short-period planets, the inner planet, WASP-47 e, has a mass (6.83 ± 0.66 {M}\\oplus ) and a radius (1.810 ± 0.027 {R}\\oplus ) that are inconsistent with an Earth-like composition. Instead, WASP-47 e likely has a volatile-rich envelope surrounding an Earth-like core and mantle. We also perform a dynamical analysis to constrain the orbital inclination of WASP-47 c, the outer Jovian planet. This planet likely orbits close to the plane of the inner three planets, suggesting a quiet dynamical history for the system. Our dynamical constraints also imply that WASP-47 c is much more likely to transit than a geometric calculation would suggest. We calculate a transit probability for WASP-47 c of about 10%, more than an order of magnitude larger than the geometric transit probability of 0.6%.

  1. Precision cluster mass determination from weak lensing

    Science.gov (United States)

    Mandelbaum, Rachel; Seljak, Uroš; Baldauf, Tobias; Smith, Robert E.

    2010-07-01

    Weak gravitational lensing has been used extensively in the past decade to constrain the masses of galaxy clusters, and is the most promising observational technique for providing the mass calibration necessary for precision cosmology with clusters. There are several challenges in estimating cluster masses, particularly (a) the sensitivity to astrophysical effects and observational systematics that modify the signal relative to the theoretical expectations, and (b) biases that can arise due to assumptions in the mass estimation method, such as the assumed radial profile of the cluster. All of these challenges are more problematic in the inner regions of the cluster, suggesting that their influence would ideally be suppressed for the purpose of mass estimation. However, at any given radius the differential surface density measured by lensing is sensitive to all mass within that radius, and the corrupted signal from the inner parts is spread out to all scales. We develop a new statistic Υ(RR0) that is ideal for estimation of cluster masses because it completely eliminates mass contributions below a chosen scale (which we suggest should be about 20 per cent of the virial radius), and thus reduces sensitivity to systematic and astrophysical effects. We use simulated and analytical profiles including shape noise to quantify systematic biases on the estimated masses for several standard methods of mass estimation, finding that these can lead to significant mass biases that range from 10 to over 50 per cent. The mass uncertainties when using the new statistic Υ(RR0) are reduced by up to a factor of 10 relative to the standard methods, while only moderately increasing the statistical errors. This new method of mass estimation will enable a higher level of precision in future science work with weak lensing mass estimates for galaxy clusters.

  2. Surviving With Smog and Smoke: Precision Interventions?

    Science.gov (United States)

    Cai, Hua; Wang, Chen

    2017-11-01

    Despite continuous efforts of regional governmental agencies, air pollution remains a major threat to public health worldwide. In January 2017, a severe episode of smog similar to the Great Smog of 1952 occurred in London. The longest episode of Chinese haze also developed in Beijing, during which levels of particulate matter smog and Chinese haze are associated with large numbers of premature deaths each year, at 400,000 and 1.2 million, respectively, primarily from respiratory diseases, cerebrovascular diseases, and ischemic heart diseases. In addition to air pollution, some are exposed to other harmful environmental factors, such as secondhand smoke. For countries with large populations of smokers, such as China, India, the United States, and Russia, surviving both smog and smoke is a serious problem. With novel genomic and epigenomic studies revealing air pollution- and smoking-induced mutational signatures and epigenetic editing in diseases such as lung cancer, it has become feasible to develop precision strategies for early intervention in the disease-causing pathways driven by the specific mutations or epigenetic regulations, or both. New therapies guided by gene-drug interactions and genomic biomarkers may also be developed. We discuss both perspectives regarding the urgent need to manage the toxic effects of smog and smoke for the benefit of global health and the novel concept of precision intervention to protect the exposed individuals when exposure to smog and secondhand smoke cannot be voluntarily avoided or easily modified. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.

  3. High precision neutron polarization for PERC

    International Nuclear Information System (INIS)

    Klauser, C.

    2013-01-01

    The decay of the free neutron into a proton, an electron and an anti-electron neutrino offers a simple system to study the semi-leptonic weak decay. High precision measurements of angular correlation coefficients of this decay provide the opportunity to test the standard model on the low energy frontier. The Proton Electron Radiation Channel PERC is part of a new generation of expriments pushing the accuracy of such an angular correlation coefficient measurement towards 10 -4 . Past experiments have been limited to an accuracy of 10 -3 with uncertainties on the neutron polarization as one of the leading systematic errors. This thesis focuses on the development of a stable, highly precise neutron polarization for a large, divergent cold neutron beam. A diagnostic tool that provides polarization higher than 99.99 % and analyzes with an accuracy of 10 -4 , the Opaque Test Bench, is presented and validated. It consists of two highly opaque polarized helium cells. The Opaque Test Bench reveals depolarizing effects in polarizing supermirrors commonly used for polarization in neutron decay experiments. These effects are investigated in detail. They are due to imperfect lateral magnetization in supermirror layers and can be minimized by significantly increased magnetizing fields and low incidence angle and supermirror factor m. A subsequent test in the crossed (X-SM) geometry demonstrated polarizations up to 99.97% from supermirrors only, improving neutron polarization with supermirrors by an order of magnitude. The thesis also discusses other neutron optical components of the PERC beamline: Monte-Carlo simulations of the beamline under consideration of the primary guide are carried out. In addition, calculation shows that PERC would statistically profit from an installation at the European Spallation source. Furthermore, beamline components were tested. A radio-frequency spin flipper was confirmed to work with an efficiency higher than 0.9999. (author) [de

  4. Using Precision in STEM Language: A Qualitative Look

    Science.gov (United States)

    Capraro, Mary M.; Bicer, Ali; Grant, Melva R.; Lincoln, Yvonna S.

    2017-01-01

    Teachers need to develop a variety of pedagogical strategies that can encourage precise and accurate communication--an extremely important 21st century skill. Precision with STEM oral language is essential. Emphasizing oral communication with precise language in combination with increased spatial skills with modeling can improve the chances of…

  5. Precise Positioning with Multi-GNSS and its Advantage for Seismic Parameters Inversion

    Science.gov (United States)

    Chen, K.; Li, X.; Babeyko, A. Y.; Ge, M.

    2015-12-01

    Together with the ongoing modernization of U.S. GPS and Russian GLONASS, the two new emerging global navigation satellite systems (BeiDou from China and Galileo from European Union) have already been running and multi-GNSS era is coming. Compared with single system, multi-GNSS can significantly improve the satellite visibility, optimize the spatial geometry, reduce dilution of precision and will be of great benefits to both scientific applications and engineering services. In this contribution, we focus mainly on its potential advantages for earthquake parameters estimation and tsunami early warning. First, we assess the precise positioning performance of multi-GNSS by an out-door experiment on a shaking table. Three positioning methods were used to retrieve the simulated seismic signal: precise point positioning (PPP), variometric approach for displacements analysis stand-alone engine (VADASE) and temporal point positioning (TPP). In addition to that, with respect to VADASE and TPP, we extended the original dual-frequency model to single-frequency model and then tested the algorithms. Accuracy, reliability, and continuity were evaluated and analyzed in detail accordingly. Our results revealed that multi-GNSS offer more precise and robust positioning results over GPS-only. At last, as a case study, multi-GNSS data recorded during 2014 Pisagua Earthquake were re-processed. Using co-seismic displacements from GPS and multi-GNSS, earthquake and the aftermath tsunami were inverted, respectively.

  6. Development of high precision and cryogenic lens holders

    Science.gov (United States)

    Reutlinger, A.; Boesz, Anton; Mottaghibonab, A.; Eckert, P.; Dubowy, M.; Gebler, H.; Grupp, F.; Geis, N.; Bode, A.; Katterloher, R.; Bender, R.

    2017-11-01

    The optical system of the Near Infrared Spectrometer and Photometer (NISP) of the EUCLID mission consists mainly of a filter and grism wheel and 4 aspherical lenses with large diameters up to 170 mm. The single lenses require a high precision positioning at the operational temperature of 150 K. An additional design driver represents the CaF2 material of a lens, which is very sensitive wrt brittleness. The technical maturity of the combination of single features such as CaF2, large diameter (and mass), high precision and cryogenic conditions is considered as low. Therefore, a dedicated pre-development program has been launched to design and develop a first prototype of lens holder and to demonstrate the functional performance at representative operational conditions. The 4 lenses are divided into 3x lenses for the Camera Lens Assembly (CaLA) and 1x lens for the Corrector Lens Assembly (CoLA). Each lens is glue mounted onto solid state springs, part of an adaption ring. The adaption ring shall provide protection against vibration loads, high accuracy positioning, as well as quasi load free mounting of the lens under operational conditions. To reduce thermomechanical loads on the lens, the CTE of the adaption ring is adapted to that of the lens. The glue between lens and solid state spring has to withstand high tension loads during vibration. At the operational temperature the deviating CTE between glue and lens/adaption ring introduces shear loads into the glue interface, which are critical, in particular for the fragile CaF2 lens material. For the case of NISP the shear loads are controlled with the glue pad diameter and the glue thickness. In the context of the development activity many technology aspects such as various solid state spring designs, glue selection and glue handling have been investigated. A parametric structural model was developed to derive the specific design feature of each ring, such as spring force, number of springs, eigenfrequency, etc. This

  7. Poly-(amidoamine) dendrimers with a precisely core positioned sulforhodamine B molecule for comparative biological tracing and profiling

    DEFF Research Database (Denmark)

    Wu, Lin-Ping; Ficker, Mario; Mejlsøe, Søren Leth

    2017-01-01

    We report on a simple robust procedure for synthesis of generation-4 poly-(amidoamine) (PAMAM) dendrimers with a precisely core positioned single sulforhodamine B molecule. The labelled dendrimers exhibited high fluorescent quantum yields where the absorbance and fluorescence spectrum of the fluo......We report on a simple robust procedure for synthesis of generation-4 poly-(amidoamine) (PAMAM) dendrimers with a precisely core positioned single sulforhodamine B molecule. The labelled dendrimers exhibited high fluorescent quantum yields where the absorbance and fluorescence spectrum...... of its coupling efficiency). Our dendrimer core-labelling approach could provide a new conceptual basis for improved understanding of dendrimer performance within biological settings...

  8. Comparison of BMD precision for Prodigy and Delphi spine and femur scans.

    Science.gov (United States)

    Shepherd, J A; Fan, B; Lu, Y; Lewiecki, E M; Miller, P; Genant, H K

    2006-01-01

    Precision error in bone mineral density (BMD) measurement can be affected by patient positioning, variations in scan analysis, automation of software, and both short- and long-term fluctuations of the densitometry equipment. Minimization and characterization of these errors is essential for reliable assessment of BMD change over time. We compared the short-term precision error of two dual-energy X-ray absorptiometry (DXA) devices: the Lunar Prodigy (GE Healthcare) and the Delphi (Hologic). Both are fan-beam DXA devices predominantly used to measure BMD of the spine and proximal femur. In this study, 87 women (mean age 61.6+/-8.9 years) were measured in duplicate, with repositioning, on both systems, at one of three clinical centers. The technologists were International Society for Clinical Densitometry (ISCD) certified and followed manufacturer-recommended procedures. All scans were acquired using 30-s scan modes. Precision error was calculated as the root-mean-square standard deviation (RMS-SD) and coefficient of variation (RMS-%CV) for the repeated measurements. Right and left femora were evaluated individually and as a combined dual femur precision. Precision error of Prodigy and Delphi measurements at each measurement region was compared using an F test to determine significance of any observed differences. While precision errors for both systems were low, Prodigy precision errors were significantly lower than Delphi at L1-L4 spine (1.0% vs 1.2%), total femur (0.9% vs 1.3%), femoral neck (1.5% vs 1.9%), and dual total femur (0.6% vs 0.9%). Dual femur modes decreased precision errors by approximately 25% compared with single femur results. This study suggests that short-term BMD precision errors are skeletal-site and manufacturer specific. In clinical practice, precision should be considered when determining: (a) the minimum time interval between baseline and follow-up scans and (b) whether a statistically significant change in the patient's BMD has occurred.

  9. Precise nuclear physics for the sun

    Energy Technology Data Exchange (ETDEWEB)

    Bemmerer, Daniel

    2012-07-01

    For many centuries, the study of the Sun has been an important testbed for understanding stars that are further away. One of the first astronomical observations Galileo Galilei made in 1612 with the newly invented telescope concerned the sunspots, and in 1814, Joseph von Fraunhofer employed his new spectroscope to discover the absorption lines in the solar spectrum that are now named after him. Even though more refined and new modes of observation are now available than in the days of Galileo and Fraunhofer, the study of the Sun is still high on the agenda of contemporary science, due to three guiding interests. The first is connected to the ages-old human striving to understand the structure of the larger world surrounding us. Modern telescopes, some of them even based outside the Earth's atmosphere in space, have succeeded in observing astronomical objects that are billions of light-years away. However, for practical reasons precision data that are important for understanding stars can still only be gained from the Sun. In a sense, the observations of far-away astronomical objects thus call for a more precise study of the closeby, of the Sun, for their interpretation. The second interest stems from the human desire to understand the essence of the world, in particular the elementary particles of which it consists. Large accelerators have been constructed to produce and collide these particles. However, man-made machines can never be as luminous as the Sun when it comes to producing particles. Solar neutrinos have thus served not only as an astronomical tool to understand the Sun's inner workings, but their behavior on the way from the Sun to the Earth is also being studied with the aim to understand their nature and interactions. The third interest is strictly connected to life on Earth. A multitude of research has shown that even relatively slight changes in the Earth's climate may strongly affect the living conditions in a number of densely

  10. Precise nuclear physics for the sun

    International Nuclear Information System (INIS)

    Bemmerer, Daniel

    2012-01-01

    For many centuries, the study of the Sun has been an important testbed for understanding stars that are further away. One of the first astronomical observations Galileo Galilei made in 1612 with the newly invented telescope concerned the sunspots, and in 1814, Joseph von Fraunhofer employed his new spectroscope to discover the absorption lines in the solar spectrum that are now named after him. Even though more refined and new modes of observation are now available than in the days of Galileo and Fraunhofer, the study of the Sun is still high on the agenda of contemporary science, due to three guiding interests. The first is connected to the ages-old human striving to understand the structure of the larger world surrounding us. Modern telescopes, some of them even based outside the Earth's atmosphere in space, have succeeded in observing astronomical objects that are billions of light-years away. However, for practical reasons precision data that are important for understanding stars can still only be gained from the Sun. In a sense, the observations of far-away astronomical objects thus call for a more precise study of the closeby, of the Sun, for their interpretation. The second interest stems from the human desire to understand the essence of the world, in particular the elementary particles of which it consists. Large accelerators have been constructed to produce and collide these particles. However, man-made machines can never be as luminous as the Sun when it comes to producing particles. Solar neutrinos have thus served not only as an astronomical tool to understand the Sun's inner workings, but their behavior on the way from the Sun to the Earth is also being studied with the aim to understand their nature and interactions. The third interest is strictly connected to life on Earth. A multitude of research has shown that even relatively slight changes in the Earth's climate may strongly affect the living conditions in a number of densely populated areas

  11. Programming supramolecular biohybrids as precision therapeutics.

    Science.gov (United States)

    Ng, David Yuen Wah; Wu, Yuzhou; Kuan, Seah Ling; Weil, Tanja

    2014-12-16

    CONSPECTUS: Chemical programming of macromolecular structures to instill a set of defined chemical properties designed to behave in a sequential and precise manner is a characteristic vision for creating next generation nanomaterials. In this context, biopolymers such as proteins and nucleic acids provide an attractive platform for the integration of complex chemical design due to their sequence specificity and geometric definition, which allows accurate translation of chemical functionalities to biological activity. Coupled with the advent of amino acid specific modification techniques, "programmable" areas of a protein chain become exclusively available for any synthetic customization. We envision that chemically reprogrammed hybrid proteins will bridge the vital link to overcome the limitations of synthetic and biological materials, providing a unique strategy for tailoring precision therapeutics. In this Account, we present our work toward the chemical design of protein- derived hybrid polymers and their supramolecular responsiveness, while summarizing their impact and the advancement in biomedicine. Proteins, in their native form, represent the central framework of all biological processes and are an unrivaled class of macromolecular drugs with immense specificity. Nonetheless, the route of administration of protein therapeutics is often vastly different from Nature's biosynthesis. Therefore, it is imperative to chemically reprogram these biopolymers to direct their entry and activity toward the designated target. As a consequence of the innate structural regularity of proteins, we show that supramolecular interactions facilitated by stimulus responsive chemistry can be intricately designed as a powerful tool to customize their functions, stability, activity profiles, and transportation capabilities. From another perspective, a protein in its denatured, unfolded form serves as a monodispersed, biodegradable polymer scaffold decorated with functional side

  12. Active vibration isolation of high precision machines

    CERN Document Server

    Collette, C; Artoos, K; Hauviller, C

    2010-01-01

    This paper provides a review of active control strategies used to isolate high precisionmachines (e.g. telescopes, particle colliders, interferometers, lithography machines or atomic force microscopes) from external disturbances. The objective of this review is to provide tools to develop the best strategy for a given application. Firstly, the main strategies are presented and compared, using single degree of freedom models. Secondly, the case of huge structures constituted of a large number of elements, like particle colliders or segmented telescopes, is considered.

  13. Precise orbit analysis and global verification results from ERS-1 altimetry

    Science.gov (United States)

    Shum, C. K.; Tapley, B. D.; Kozel, B. J.; Visser, P.; Ries, J. C.; Seago, J.

    1994-01-01

    A technique which employs dual satellite crossover measurements from ERS-1 and Topology Ocean Experiment (TOPEX)/Poseidon together with laser tracking data and single satellite crossover measurements for ERS-1 precision orbit determination is described. The accuracy assessment of the resulting ERS-1 orbit is provided. Results of global verification of the ERS-1 Ocean Products (OPR02) and the Interim Geophysical Data Records (IGDR) data products in terms of altimeter bias, time lag bias and sea state bias are presented.

  14. Precision measurements and searches with single and multiple gauge bosons with the ATLAS detector

    CERN Document Server

    Soldatov, Evgeny; The ATLAS collaboration

    2016-01-01

    The ATLAS collaboration has carried out a set of measurements at center-of-mass energies of 8 TeV and 13 TeV which provide stringent tests of the electroweak sector of the Standard Model, specifically on di- and multibosonproduction cross sections. Such measurements include inclusive and differential cross sections for the production of two heavy gauge bosons (WW, WZ, ZZ) in the leptonic or semileptonic channels, the search for the production of three W bosons, the production of a Z boson in association with one or two photons, a Z or W boson in the vector-boson fusion channel, the observation of vector-boson scattering in the WW channel and the search for WZ production via vector-boson scattering. These measurements are compared to (N)NLO predictions of the Standard Model and provide model-independent constraints on new physics, by setting limits on anomalous triple or quartic gauge-boson couplings. We also present a measurement of the exclusive gamma+gamma >WW production cross-section and a search for exclu...

  15. Analytical error reduction using single point calibration for accurate and precise metabolomic phenotyping

    NARCIS (Netherlands)

    Kloet, F.M. van der; Bobeldijk, I.; Verheij, E.R.; Jellema, R.H.

    2009-01-01

    Analytical errors caused by suboptimal performance of the chosen platform for a number of metabolites and instrumental drift are a major issue in large-scale metabolomics studies. Especially for MS-based methods, which are gaining common ground within metabolomics, it is difficult to control the

  16. Precision segmented reflectors for space applications

    Science.gov (United States)

    Lehman, David H.; Pawlik, Eugene V.; Meinel, Aden B.; Fichter, W. B.

    1990-08-01

    A project to develop precision segmented reflectors (PSRs) which operate at submillimeter wavelengths is described. The development of a light efficient means for the construction of large-aperture segmented reflecting space-based telescopes is the primary aim of the project. The 20-m Large Deployable Reflector (LDR) telescope is being developed for a survey mission, and it will make use of the reflector panels and materials, structures, and figure control being elaborated for the PSR. The surface accuracy of a 0.9-m PSR panel is shown to be 1.74-micron RMS, the goal of 100-micron RMS positioning accuracy has been achieved for a 4-m erectable structure. A voice-coil actuator for the figure control system architecture demonstrated 1-micron panel control accuracy in a 3-axis evaluation. The PSR technology is demonstrated to be of value for several NASA projects involving optical communications and interferometers as well as missions which make use of large-diameter segmented reflectors.

  17. Precision Saturated Absorption Spectroscopy of H3+

    Science.gov (United States)

    Guan, Yu-chan; Liao, Yi-Chieh; Chang, Yung-Hsiang; Peng, Jin-Long; Shy, Jow-Tsong

    2016-06-01

    In our previous work on the Lamb dips of the νb{2} fundamental band of H3+, the saturated absorption spectrum was obtained by the third-derivative spectroscopy using frequency modulation [1]. However, the frequency modulation also causes error in absolute frequency determination. To solve this problem, we have built an offset-locking system to lock the OPO pump frequency to an iodine-stabilized Nd:YAG laser. With this modification, we are able to scan the OPO idler frequency precisely and obtain the profile of the Lamb dips. Double modulation (amplitude modulation of the idler power and concentration modulation of the ion) is employed to subtract the interference fringes of the signal and increase the signal-to-noise ratio effectively. To Determine the absolute frequency of the idler wave, the pump wave is offset locked on the R(56) 32-0 a10 hyperfine component of 127I2, and the signal wave is locked on a GPS disciplined fiber optical frequency comb (OFC). All references and lock systems have absolute frequency accuracy better than 10 kHz. Here, we demonstrate its performance by measuring one transition of methane and sixteen transitions of H3+. This instrument could pave the way for the high-resolution spectroscopy of a variety of molecular ions. [1] H.-C. Chen, C.-Y. Hsiao, J.-L. Peng, T. Amano, and J.-T. Shy, Phys. Rev. Lett. 109, 263002 (2012).

  18. A precision measurement of muon decay

    Energy Technology Data Exchange (ETDEWEB)

    Quraan, M.A.; Amaudruz, P.; Andersson, W.; Comyn, M.; Davydov, Yu.; Depommier, P.; Doornbos, J.; Faszer, W.; Gagliardi, C.A.; Gill, D.R.; Green, P.; Gumplinger, P.; Hardy, J.C.; Hasinoff, M.; Helmer, R.; Henderson, R.; Khruchinsky, A.; Kitching, P.; Koetke, D.D.; Korkmaz, E.; Lachin, Y.; Mass, D.; Macdonald, J.A.; Manweiler, R.; Mathie, T.; Musser, J.R.; Nord, P.; Olin, A.; Ottewell, D.; Openshaw, R.; Piilonen, L.; Porcelli, T.; Poutissou, J-M.; Poutissou, R.; Rodning, N.L.; Schaapman, J.; Selivanov, V.; Sheffer, G.; Shin, Y.; Sobratee, F.; Soukup, J.; Stanislaus, T.D.S.; Stinson, G.; Tacik, R.; Torokhov, V.; Tribble, R.E.; Vasiliev, M.A.; Walter, H.K.; Wright, D

    2000-01-31

    The V-A structure of the weak interaction was put into the standard model by hand in order to obtain agreement with experiments. These experiments, however, do not rule out relatively large deviations from this structure. Muon decay provides an ideal laboratory to test this structure, being a purely leptonic process. TRIUMF experiment E614 will measure both the energy and emission-angle distribution of positrons from the decay of polarized muons. This will provide a simultaneous determination of the Michel parameters P{sub {mu}}{xi}, {rho} and {delta} describing muon decay with a precision of a few parts in 10{sup 4}. Stringent limits may then be placed on the coupling constants, as well as the mass and mixing angle of a possible right-handed W boson (W{sub R}). In this paper the formalism for muon decay is presented, the E614 experiment is described, and the sensitivity expected from E614 is compared to present limits on the values of the coupling constants and the mass and mixing angle of W{sub R}.

  19. Light top partners and precision physics

    CERN Document Server

    Grojean, Christophe; Panico, Giuliano

    2013-01-01

    We analyze the corrections to the precision EW observables in minimal composite Higgs models by using a general effective parametrization which also includes the lightest fermionic resonances. A new, possibly large, logarithmically divergent contribution to S is identified, which comes purely from the strong dynamics. It can be interpreted as a running of S induced by the non-renormalizable Higgs interactions due to the non-linear sigma-model structure. As expected, the corrections to the T parameter coming from fermion loops are finite and dominated by the contributions of the lightest composite states. The fit of the oblique parameters suggests a rather stringent lower bound on the sigma-model scale f > 750GeV. The corrections to the Z bL bL vertex coming from the lowest-order operators in the effective Lagrangian are finite and somewhat correlated to the corrections to T. Large additional contributions are generated by contact interactions with 4 composite fermions. In this case a logarithmic divergence ca...

  20. Precision diboson observables for the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Frye, Christopher [Department of Physics, Harvard University,17 Oxford St, Cambridge, MA 02138 (United States); Freytsis, Marat [Department of Physics, Harvard University,17 Oxford St, Cambridge, MA 02138 (United States); Institute of Theoretical Science, University of Oregon,1585 E 13th Ave, Eugene, OR 97403 (United States); Scholtz, Jakub; Strassler, Matthew J. [Department of Physics, Harvard University,17 Oxford St, Cambridge, MA 02138 (United States)

    2016-03-24

    Motivated by the restoration of SU(2)×U(1) at high energy, we suggest that certain ratios of diboson differential cross sections can be used as high-precision observables at the LHC. We rewrite leading-order diboson partonic cross sections in a form that makes their SU(2)×U(1) and custodial SU(2) structure more explicit than in previous literature, and identify important aspects of this structure that survive even in hadronic cross sections. We then focus on higher-order corrections to ratios of γγ, Zγ and ZZ processes, including full next-to-leading-order corrections and gg initial-state contributions, and argue that these ratios can likely be predicted to better than 5%, which should make them useful in searches for new phenomena. The ratio of Zγ to γγ is especially promising in the near term, due to large rates and to exceptional cancellations of QCD-related uncertainties. We argue that electroweak corrections are moderate in size, have small uncertainties, and can potentially be observed in these ratios in the long run.

  1. Cold Antihydrogen for Precise Laser Spectroscopy

    CERN Multimedia

    Gabrielse, G S; Walz, J; Hessels, E A; Tan, J; Oelert, W; George, M C; Grzonka, D J; Kossick, M; Storry, C H; Sefzick, T

    2002-01-01

    %AD-2 %title\\\\ \\\\The Antihydrogen TRAP Collaboration (ATRAP) seeks to do precise laser spectroscopy of antihydrogen. Comparisons of antihydrogen and hydrogen atoms should provide the most stringent test of CPT invariance involving baryons and leptons. ATRAP is an expansion of the TRAP collaboration that developed the techniques to take CERN antiprotons from an energy of 6 MeV (momentum 100 MeV/c) all the way down to thermal equilibrium at 4 K for storage. This storage energy is lower than realized previously by more than ten orders of magnitude. The TRAP techniques include slowing, capturing, electron cooling and stacking of antiprotons. ATRAP and other collaborations will use antiprotons from the Antiproton Decelerator (AD). This new facility makes sense for such experiments because we showed that antiprotons can be accumulated in a trap at much lower expense than was required in the earlier CERN AC-AA-LEAR complex. In the closest approach yet to the production of cold antihydrogen, collaboration members wer...

  2. RPCs: the choreography of precise timing

    CERN Document Server

    Boyko, I; Dydak, F; Elagin, A; Gostkin, M; Koreshev, V; Nefedov, Y; Nikolaev, K; Wotschack, J; Zhemchugov, A

    2005-01-01

    We present a comprehensive overview of all steps to be taken in order to achieve precise timing of the HARP RPCs. After briefly recalling the salient features of the RPC mechanics and electronics, we discuss the results from the dedicated calibration scan in a -12 GeV/c beam which gave valuable first information on efficiency and uniformity of response, charge attenuation, the global time slewing correction, effective strip transit time, relative delays between strips of a pad, and intrinsic time resolution. The latter was determined to be ~140 ps which sets the scale for the control of systematic effects, so as not to deteriorate significantly the overall time-of-flight resolution of the RPCs. From physics data, primarily from `neutral' and `charged' hits in RPC overlap regions, further refinements are derived, in particular padring-specific modifications of the global time slewing correction, and manifestations of the `knock-on' and noise' effects. With a view to a bias-free determination of pad-specific t0...

  3. Precision electroweak measurements on the $Z$ resonance

    CERN Document Server

    Schael, S; Brunelière, R; Buskulic, Damir; De Bonis, I; Décamp, D; Ghez, P; Goy, C; Jézéquel, S; Lees, J P; Lucotte, A; Martin, F; Merle, E; Minard, M N; Nief, J Y; Odier, P; Pietrzyk, B; Trocmé, B; Bravo, S; Casado, M P; Chmeissani, M; Comas, P; Crespo, J M; Fernández, E; Fernández-Bosman, M; Garrido, L; Graugès-Pous, E; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Orteu, S; Pacheco, A; Park, I C; Perlas, J; Riu, I; Ruiz, H; Sánchez, F; Colaleo, A; Creanza, D; De Filippis, N; De Palma, M; Iaselli, G; Maggi, G; Maggi, M; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Bazarko, A; Becker, U; Boix, G; Bird, F; Blucher, E; Bonvicini, B; Bright-Thomas, P; Barklow, T; Cattaneo, M; Cerutti, F; Clerbaux, B; Drevermann, H; Forty, R W; Frank, M; Greening, T C; Hagelberg, R; Halley, A W; Gianotti, F; Girone, M; Hansen, J B; Harvey, J; Jacobsen, R; Hutchcroft, D E; Janot, P; Jost, B; Knobloch, J; Kado, M; Lehraus, Ivan; Lazeyras, Pierre; Maley, P; Mato, P; May, J; Moutoussi, A; Pepé-Altarelli, M; Ranjard, F; Rolandi, Luigi; Schlatter, W D; Schmitt, B; Schneider, O; Tejessy, W; Teubert, F; Tomalin, I R; Tournefier, E; Veenhof, R; Valassi, A; Wiedenmann, W; Wright, A E; Ajaltouni, Ziad J; Badaud, F; Chazelle, G; Deschamps, O; Dessagne, S; Falvard, A; Ferdi, C; Fayolle, D; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Pascolo, J M; Perret, P; Podlyski, F; Bertelsen, H; Fernley, T; Hansen, J D; Hansen, J R; Hansen, P H; Kraan, A C; Lindahl, A; Møllerud, R; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, E; Siotis, I; Vayaki, A; Blondel, A; Bonneaud, G; Brient, J C; Machefert, F; Rougé, A; Rumpf, M; Swynghedauw, M; Tanaka, R; Verderi, M; Videau, H L; Ciulli, V; Focardi, E; Parrini, G; Zachariadou, K; Corden, M; Georgiopoulos, C H; Antonelli, A; Antonelli, M; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, G P; Passalacqua, L; Picchi, P; Colrain, P; ten Have, I; Hughes, I S; Kennedy, J; Knowles, I G; Lynch, J G; Morton, W T; Negus, P; O'Shea, V; Raine, C; Reeves, P; Scarr, J M; Smith, K; Thompson, A S; Turnbull, R M; Wasserbaech, S R; Buchmüller, O L; Cavanaugh, R J; Dhamotharan, S; Geweniger, C; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, W; Wunsch, M; Beuselinck, R; Binnie, D M; Cameron, W; Davies, G; Dornan, P J; Goodsir, S M; Marinelli, N; Martin, E; Nash, J; Nowell, J; Rutherford, S A; Sedgbeer, J K; Thompson, J C; White, R; Williams, M D; Ghete, V M; Girtler, P; Kneringer, E; Kuhn, D; Rudolph, G; Bouhova-Thacker, E; Bowdery, C K; Buck, P G; Clarke, D P; Ellis, G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Keemer, N R; Pearson, M R; Robertson, N A; Sloan, T; Smizanska, M; Snow, S W; Williams, M I; van der Aa, O; Delaere, C; Leibenguth, G; Lemaître, V; Bauerdick, L A T; Blumenschein, U; Van Gemmeren, P; Giehl, I; Hölldorfer, F; Jakobs, K; Kasemann, M; Kayser, F; Kleinknecht, K; Müller, A S; Quast, G; Renk, B; Rohne, E; Sander, H G; Schmeling, S; Wachsmuth, H W; Wanke, R; Zeitnitz, C; Ziegler, T; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Carr, J; Coyle, P; Curtil, C; Ealet, A; Etienne, F; Fouchez, D; Motsch, F; Payre, P; Rousseau, D; Talby, M; Thulasidas, M; Aleppo, M; Ragusa, F; Büscher, V; David, A; Dietl, H; Ganis, G; Hüttmann, K; Lütjens, G; Mannert, C; Männer, W; Moser, H G; Settles, R; Seywerd, H; Stenzel, H; Villegas, M; Wolf, G; Boucrot, J; Callot, O; Chen, S; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Jacholkowska, A; Le Diberder, F R; Lefrançois, J; Mutz, A M; Schune, M H; Serin, L; Veillet, J J; Videau, I; Zerwas, D; Azzurri, P; Bagliesi, G; Bettarini, S; Boccali, T; Bozzi, C; Calderini, G; Dell'Orso, R; Fantechi, R; Ferrante, I; Fidecaro, F; Foà, L; Giammanco, A; Giassi, A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, F; Rizzo, G; Sanguinetti, G; Sciabà, A; Sguazzoni, G; Spagnolo, P; Steinberger, J; Tenchini, R; Vannini, C; Venturi, A; Verdini, P G; Awunor, O; Blair, G A; Cowan, G; García-Bellido, A; Green, M G; Medcalf, T; Strong, J A; Teixeira-Dias, P; Botterill, David R; Clifft, R W; Edgecock, T R; Edwards, M; Haywood, S J; Norton, P R; Ward, J J; Bloch-Devaux, B; Boumediene, D E; Colas, P; Emery, S; Fabbro, B; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Tuchming, B; Vallage, B; Black, S N; Dann, J H; Kim, H Y; Konstantinidis, N P; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Cartwright, S; Combley, F; Hodgson, P N; Lehto, M H; Thompson, L F; Affholderbach, K; Barberio, E; Böhrer, A; Brandt, S; Burkhardt, H; Feigl, E; Grupen, C; Hess, J; Lutters, G; Meinhard, H; Minguet-Rodríguez, J A; Mirabito, L; Misiejuk, A; Neugebauer, E; Ngac, A; Prange, G; Rivera, F; Saraiva, P; Schäfer, U; Sieler, U; Smolik, L; Stephan, F; Trier, H; Apollonio, M; Borean, C; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Pitis, L; He, H; Kim, H; Pütz, J; Rothberg, J E; Armstrong, S R; Bellantoni, L; Berkelman, K; Cinabro, D; Conway, J S; Cranmer, K; Elmer, P; Feng, Z; Ferguson, D P S; Gao, Y; González, S; Grahl, J; Harton, J L; Hayes, O J; Hu, H; Jin, S; Johnson, R P; Kile, J; McNamara, P A; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Sharma, V; Walsh, A M; Walsh, J; Wear, J; Von Wimmersperg-Töller, J H; Wu, J; Wu, S L; Wu, X; Yamartino, J M; Zobernig, G; Dissertori, G; Abdallah, J; Abreu, P; Adam, W; Adye, T; Adzic, P; Ajinenko, I; Albrecht, T; Alderweireld, T; Alekseev, G D; Alemany-Fernandez, R; Allmendinger, T; Allport, P P; Almehed, S; Amaldi, Ugo; Amapane, N; Amato, S; Anashkin, E; Anassontzis, E G; Andersson, P; Andreazza, A; Andringa, S; Anjos, N; Antilogus, P; Apel, W D; Arnoud, Y; Ask, S; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Ballestrero, A; Bambade, P; Barão, F; Barbiellini, G; Barbier, R; Bardin, D; Barker, G; Baroncelli, A; Battaglia, M; Baubillier, M; Becks, K H; Begalli, M; Behrmann, A; Beillière, P; Belokopytov, Yu A; Belous, K S; Ben-Haim, E; Benekos, N; Benvenuti, A C; Bérat, C; Berggren, M; Berntzon, L; Bertini, D; Bertrand, D; Besançon, M; Besson, N; Bianchi, F; Bigi, M; Bilenky, S M; Bizouard, M A; Bloch, D; Blom, M; Bluj, M; Bonesini, M; Bonivento, W; Boonekamp, M; Booth, P S L; Borgland, A W; Borisov, G; Bosio, C; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Boyko, I; Bozovic, I; Bozzo, M; Bracko, M; Branchini, P; Brenke, T; Brenner, R; Brodet, E; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschbeck, Brigitte; Buschmann, P; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Carena, F; Carroll, L; Caso, C; Castillo-Gimenez, M V; Castro, N; Cattai, A; Cavallo, F; Chabaud, V; Chapkin, M; Charpentier, P; Chaussard, L; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Shlyapnikov, P; Chochula, P; Chorowicz, V; Chudoba, J; Chung, S U; Cieslik, K; Collins, P; Colomer, M; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Costa, M J; Cowell, J H; Crawley, H B; Crennell, D J; Crépé, S; Crosetti, G; Cuevas-Maestro, J; Czellar, S; D'Hondt, J; D'Almagne, B; Dalmau, J; Damgaard, G; Davenport, M; Da Silva, T; Da Silva, W; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; De Lotto, B; De Maria, N; De Min, A; De Paula, L; Dijkstra, H; Di Ciaccio, L; Di Diodato, A; Di Simone, A; Djannati, A; Dolbeau, J; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Duperrin, A; Durand, J D; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, G; Ellert, M; Elsing, M; Engel, J P; Erzen, B; Espirito-Santo, M C; Falk, E; Fanourakis, G K; Fassouliotis, D; Fayot, J; Feindt, M; Fenyuk, A; Fernández, J; Ferrari, P; Ferrer, A; Ferrer-Ribas, E; Ferro, F; Fichet, S; Firestone, A; Fischer, P A; Flagmeyer, U; Föth, H; Fokitis, E; Fontanelli, F; Franek, B; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J; Galloni, A; Gamba, D; Gamblin, S; Gandelman, M; García, C; García, J; Gaspar, C; Gaspar, M; Gasparini, U; Gavillet, P; Gazis, E; Gelé, D; Gerber, J P; Gerdyukov, L N; Ghodbane, N; Gil, I; Glege, F; Gokieli, R; Golob, B; Gómez-Ceballos, G; Gonçalves, P; González-Caballero, I; Gopal, G; Gorn, L; Górski, M; Guz, Yu; Gracco, Valerio; Graziani, E; Green, C; Grefrath, A; Grimm, H J; Gris, P; Grosdidier, G; Grzelak, K; Günther, M; Guy, J; Haag, C; Hahn, F; Hahn, S; Haider, S; Hallgren, A; Hamacher, K; Hamilton, K; Hansen, J; Harris, F J; Haug, S; Hauler, F; Hedberg, V; Heising, S; Hennecke, M; Henriques, R; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Heuser, J M; Higón, E; Hoffman, J; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Hrubec, Josef; Huber, M; Huet, K; Hughes, G J; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Jeans, D; Johansson, E K; Johansson, P D; Jonsson, P; Joram, C; Juillot, P; Jungermann, L; Kapusta, F; Karafasoulis, K; Katsanevas, S; Katsoufis, E C; Keränen, R; Kernel, G; Kersevan, B P; Kerzel, U; Khomenko, B A; Khovanskii, N N; Kiiskinen, A P; King, B T; Kinvig, A; Kjaer, N J; Klapp, O; Klein, H; Kluit, P; Knoblauch, D; Kokkinias, P; Konoplyannikov, A K; Koratzinos, M; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Krammer, M; Kreuter, C; Kriznic, E; Krstic, J; Krumshtein, Z; Kubinec, P; Kucewicz, W; Kucharczyk, M; Kurowska, J; Kurvinen, K; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Lapin, V; Laugier, J P; Lauhakangas, R; Leder, G; Ledroit, F; Lefébure, V; Leinonen, L; Leisos, A; Leitner, R; Lemonne, J; Lenzen, G; Lepeltier, V; Lesiak, T; Lethuillier, M; Libby, J; Liebig, W; Liko, D; Lipniacka, A; Lippi, I; Lörstad, B; Lokajícek, M; Loken, J G; Lopes, J H; López, J M; López-Fernandez, R; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J; Mahon, J R; Maio, A; Malek, A; Malmgren, T G M; Maltezos, S; Malychev, V; Mandl, F; Marco, J; Marco, R; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Masik, J; Mastroyiannopoulos, N; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, F; Mazzucato, M; McCubbin, M; McKay, R; McNulty, R; McPherson, G; Meroni, C; Meyer, W T; Myagkov, A; Migliore, E; Mitaroff, W A; Mjörnmark, U; Moa, T; Moch, M; Møller, R; Mönig, K; Monge, R; Montenegro, J; Moraes, D; Moreau, X; Moreno, S; Morettini, P; Morton, G; Müller, U; Münich, K; Mulders, M; Mulet-Marquis, C; Mundim, L; Muresan, R; Murray, W; Muryn, B; Myatt, G; Myklebust, T; Naraghi, F; Nassiakou, M; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Neufeld, N; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Niezurawski, P; Nikolaenko, V; Nikolenko, M; Nomokonov, V P; Normand, A; Nygren, A; Oblakowska-Mucha, A; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, R; Orazi, G; Österberg, K; Ouraou, A; Oyanguren, A; Paganini, P; Paganoni, M; Paiano, S; Pain, R; Paiva, R; Palacios, J P; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Parzefall, U; Passeri, A; Passon, O; Pavel, T; Pegoraro, M; Peralta, L; Perepelitsa, V F; Pernicka, M; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Piedra, J; Pieri, L; Pierre, F; Pimenta, M; Piotto, E; Podobnik, T; Poireau, V; Pol, M E; Polok, G; Polycarpo, E; Poropat, P; Pozdnyakov, V; Privitera, P; Pukhaeva, N; Pullia, A; Radojicic, D; Ragazzi, S; Rahmani, H; Rakoczy, D; Rames, J; Ramler, L; Ratoff, P N; Read, A; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Rehn, J; Reid, D; Reinhardt, R; Renton, P B; Resvanis, L K; Richard, F; Rídky, J; Rinaudo, G; Ripp-Baudot, I; Rivero, M; Rodríguez, D; Rohne, O; Romero, A; Ronchese, P; Rosenberg, E I; Rosinsky, P; Roudeau, P; Rovelli, T; Royon, C; Ruhlmann-Kleider, V; Ruiz, A; Ryabtchikov, D; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salmi, L; Salt, J; Sampsonidis, D; Sannino, M; Savoy-Navarro, A; Scheidle, T; Schneider, H; Schwemling, P; Schwering, B; Schwickerath, U; Schyns, M A E; Scuri, F; Seager, P; Sedykh, Yu; Segar, A; Seibert, N; Sekulin, R L; Shellard, R C; Sheridan, A; Siebel, M; Silvestre, R; Simard, L; Simonetto, F; Sisakian, A; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O; Smith, G R; Sokolov, A; Sopczak, A; Sosnowski, R; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stampfer, D; Stanescu, C; Stanic, S; Stanitzki, M; Stapnes, S; Stevenson, K; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Szumlak, T; Tabarelli de Fatis, T; Taffard, A C; Tegenfeldt, F; Terranova, F; Thomas, J; Tilquin, A; Timmermans, J; Tinti, N; Tkatchev, L G; Tobin, M; Todorov, T; Todorovova, S; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tortosa, P; Tranströmer, G; Travnicek, P; Treille, D; Tristram, G; Trochimczuk, M; Trombini, A; Troncon, C; Tsirou, A; Turluer, M L; Tyapkin, I A; Tyapkin, P; Tzamarias, S; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; Van der Velde, C; van Apeldoorn, G W; van Dam, P; Van den Boeck, W; Van Doninck, W K; Van Eldik, J; Van Lysebetten, A; Van Remortel, N; Van Vulpen, I; Vassilopoulos, N; Vegni, G; Veloso, F; Ventura, L; Venus, W; Verbeure, F; Verdier, P; Verlato, M; Vertogradov, L S; Verzi, V; Vilanova, D; Vitale, L; Vlasov, E; Vodopyanov, A S; Vollmer, C; Voulgaris, G; Vrba, V; Wahlen, H; Walck, C; Washbrook, A J; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J; Wilkinson, G; Winter, M; Witek, M; Wlodek, T; Yi, J; Yushchenko, O P; Zaitsev, A; Zalewska-Bak, A; Zalewski, P; Zavrtanik, D; Zevgolatakos, E; Zhuravlov, V; Zimin, N I; Zintchenko, A; Zoller, P; Zucchelli, G C; Zumerle, G; Zupan, M; Acciarri, M; Achard, P; Adriani, O; Aguilar-Benítez, M; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alviggi, M G; Ambrosi, G; Anderhub, H; Andreev, V P; Angelescu, T; Anselmo, F; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Bajo, A; Baksay, G; Baksay, L; Balandras, A; Baldew, S V; Ball, R C; Banerjee, S; Banerjee, Sw; Barczyk, A; Barillère, R; Barone, L; Bartalini, P; Basile, M; Batalova, N; Battiston, R; Bay, A; Becattini, F; Behner, F; Bellucci, L; Berbeco, R; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Bhattacharya, S; Biasini, M; Biglietti, M; Biland, A; Blaising, J J; Blyth, S C; Bobbink, G J; Böhm, A; Boldizsar, L; Borgia, B; Bottai, S; Bourilkov, D; Bourquin, M; Braccini, S; Branson, J G; Brigljevic, V; Brochu, F; Brock, I C; Buffini, A; Buijs, A; Burger, J D; Burger, W J; Button, A J; Cai, X D; Campanelli, M; Capell, M; Cara Romeo, G; Carlino, G; Cartacci, A; Casaus, J; Castellini, G; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada, M; Cesaroni, F; Chamizo-Llatas, M; Chang, Y H; Chaturvedi, U K; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chiefari, G; Cifarelli, L; Cindolo, F; Civinini, C; Clare, I; Clare, R; Coignet, G; Colijn, A P; Colino, N; Costantini, S; Cotorobai, F; Cozzoni, B; de la Cruz, B; Csilling, A; Cucciarelli, S; Dai, T S; van Dalen, J A; D'Alessandro, R; De Asmundis, R; Debreczeni, J; Deglon, P; Degré, A; Dehmelt, K; Deiters, K; Della Volpe, D; Delmeire, E; Denes, P; De Notaristefani, F; De Salvo, A; Diemoz, M; Dierckxsens, M; Van Dierendonck, D N; Di Lodovico, F; Dionisi, C; Dittmar, M; Dominguez, A; Doria, A; Dova, M T; Duchesneau, D; Dufournaud, D; Duda, M; Duinker, P; Durán, I; Dutta, S; Echenard, B; Eline, A; El-Hage, A; El-Mamouni, H; Engler, A; Eppling, F J; Erné, F C; Extermann, P; Fabre, M; Faccini, R; Falagán, M A; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, M; Ferguson, T; Ferroni, F; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, F; Fisher, P H; Fisher, W; Fisk, I; Forconi, G; Fredj, L; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gataullin, M; Gau, S S; Gentile, S; Gheordanescu, N; Giagu, S; Gong, Z F; Grenier, G; Grimm, O; Grünewald, M W; Guida, M; van Gulik, R; Gupta, V K; Gurtu, A; Gutay, L J; Haas, D; Hasan, A; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Hidas, P; Hirschfelder, J; Hofer, H; Hohlmann, M; Holzner, G; Hoorani, H; Hou, S R; Iashvili, I; Innocente, V; Jin, B N; Jindal, P; Jones, L W; de Jong, P; Josa-Mutuberria, I; Khan, R A; Kaur, M; Kienzle-Focacci, M N; Kim, D; Kim, J K; Kirkby, Jasper; Kiss, D; Kittel, E W; Klimentov, A; König, A C; Koffeman, E; Kopal, M; Kopp, A; Koutsenko, V F; Kraber, M; Krämer, R W; Krenz, W; Krüger, A; Kuijten, H; Kunin, A; Ladrón de Guevara, P; Laktineh, I; Landi, G; Lassila-Perini, K M; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Lee, H J; Le Goff, J M; Leiste, R; Leonardi, E; Levtchenko, M; Levchenko, P M; Li, C; Likhoded, S; Lin, C H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lü, Y S; Lu, W; Lübelsmeyer, K; Luci, C; Luckey, D; Luminari, L; Lugnier, L; Lustermann, W; Ma, W G; Maity, M; Malgeri, L; Malinin, A; Maña, C; Mangeol, D J J; Mans, J; Marchesini, P A; Marian, G; Martin, J P; Marzano, F; Massaro, G G G; Mazumdar, K; McNeil, R R; Mele, S; Merola, L; Merk, M; Meschini, M; Metzger, W J; Von der Mey, M; Mihul, A; Milcent, H; Mirabelli, G; Mnich, J; Mohanty, G B; Molnár, P; Monteleoni, B; Moulik, T; Muanza, G S; Muheim, F; Muijs, A J M; Musicar, B; Musy, M; Nagy, S; Natale, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Niessen, T; Nisati, A; Novák, T; Nowak, H; Ofierzynski, R A; Organtini, G; Oulianov, A; Pal, I; Palomares, C; Pandoulas, D; Paoletti, S; Paoloni, A; Paolucci, P; Paramatti, R; Park, H K; Park, I H; Pascale, G; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, F; Peach, D; Pedace, M; Pensotti, S; Perret-Gallix, D; Petersen, B; Piccolo, D; Pierella, F; Pieri, M; Pioppi, M; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Postema, H; Pothier, J; Produit, N; Prokofiev, D O; Prokofev, D; Quartieri, J; Rahal-Callot, G; Rahaman, M A; Raics, P; Raja, N; Ramelli, R; Rancoita, P G; Ranieri, R; Raspereza, A V; Razis, P; Ren, D; Rescigno, M; Reucroft, S; Van Rhee, T; Riemann, S; Riles, K; Robohm, A; Rodin, J; Roe, B P; Romero, L; Rosca, A; Rosemann, C; Rosenbleck, C; Rosier-Lees, S; Roth, S; Rubio, J A; Ruggiero, G; Ruschmeier, D; Rykaczewski, H; Sakharov, A; Saremi, S; Sarkar, S; Salicio, J; Sánchez, E; Sanders, M P; Sarakinos, M E; Schäfer, C; Shchegelskii, V; Schmidt-Kärst, S; Schmitz, D; Schopper, Herwig Franz; Schotanus, D J; Schwering, G; Sciacca, C; Sciarrino, D; Seganti, A; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shumilov, E; Shvorob, A; Siedenburg, T; Son, D; Smith, B; Souga, C; Spillantini, P; Steuer, M; Stickland, D P; Stone, A; Stone, H; Stoyanov, B; Strässner, A; Sudhakar, K; Sultanov, G G; Sun, L Z; Sushkov, S; Suter, H; Swain, J D; Szillási, Z; Sztaricskai, T; Tang, X W; Tarjan, P; Tauscher, L; Taylor, L; Tellili, B; Teyssier, D; Timmermans, C; Ting, Samuel C C; Ting, S M; Tonwar, S C; Tóth, J; Tully, C; Tung, K L; Uchida, Y; Ulbricht, J; Uwer, U; Valente, E; Van de Walle, R T; Vásquez, R; Veszpremi, V; Vesztergombi, G; Vetlitskii, I; Vicinanza, D; Viertel, G; Villa, S; Vivargent, M; Vlachos, S; Vodopyanov, I; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Vorvolakos, A; Wadhwa, M; Wallraff, W; Wang, Q; Wang, X L; Wang, Z M; Weber, A; Weber, M; Wienemann, P; Wilkens, H; Wu, S X; Wynhoff, S; Xia, L; Xu, Z Z; Yamamoto, J; Yang, B Z; Yang, C G; Yang, H J; Yang, M; Ye, J B; Yeh, S C; You, J M; Zalite, A; Zalite, Yu; Zhang, Z P; Zhao, J; Zhu, G Y; Zhu, R Y; Zhuang, H L; Zichichi, A; Zilizi, G; Zimmermann, B; Zöller, M; Abbiendi, G; Ainsley, C; Åkesson, P F; Alexander, G; Allison, J; Altekamp, N; Amaral, P; Ametewee, K A; Anagnostou, G; Anderson, K J; Anderson, S; Arcelli, S; Armitage, J C; Asai, S; Ashby, S F; Ashton, P; Astbury, A; Axen, D; Azuelos, Georges; Bahan, G A; Bailey, I; Baines, J T M; Ball, A H; Banks, J; Barillari, T; Barker, G J; Barlow, R J; Barnett, S; Bartoldus, R; Batley, J Richard; Beaudoin, G; Bechtle, P; Bechtluft, J; Beck, A; Becker, J; Beeston, C; Behnke, T; Bell, A N; Bell, K W; Bell, P J; Bella, G; Bellerive, A; Benelli, G; Bentvelsen, Stanislaus Cornelius Maria; Berlich, P; Bethke, Siegfried; Biebel, O; Binder, U; Blobel, Volker; Bloodworth, Ian J; Bloomer, J E; Bock, P; Boden, B; Böhme, J; Boeriu, O; Bonacorsi, D; Bosch, H M; Bougerolle, S; Boutemeur, M; Bouwens, B T; Brabson, B B; Braibant, S; Breuker, H; Brigliadori, L; Brown, R M; Brun, R; Bürgin, R; Büsser, K; Burckhart, H J; Burgard, C; Cammin, J; Campana, S; Capiluppi, P; Carnegie, R K; Caron, B; Carter, A A; Carter, J R; Chang, C Y; Charlesworth, C; Charlton, D G; Chrin, J T M; Chrisman, D; Chu, S L; Ciocca, C; Clarke, P E L; Clay, E; Clayton, J C; Cohen, I; Collins, W J; Conboy, J E; Cooke, O C; Cooper, M; Couch, M; Couchman, J; Coupland, M; do Couto e Silva, E; Coxe, R L; Cuffiani, M; Dado, S; Dallapiccola, C; Dallavalle, G M; Dallison, S; Darling, C; De Jong, S; de Roeck, A; De Wolf, E A; Debu, P; Deng, H; Deninno, M M; Dervan, P; Desch, Klaus; Dieckmann, A; Dienes, B; Dixit, M S; Donkers, M; Doucet, M; Dubbert, J; Duchovni, E; Duckeck, G; Duerdoth, I P; Dumas, D J P; Eckerlin, G; Edwards, J E G; Elcombe, P A; Estabrooks, P G; Evans, H G; Evans, M; Fabbri, F; Fanti, M; Fath, P; Feld, L; Fiedler, F; Fierro, M; Fincke-Keeler, M; Fischer, H M; Fleck, I; Folman, R; Fong, D G; Ford, M; Foucher, M; Frey, A; Fürtjes, A; Fukui, H; Fukunaga, C; Futyan, D I; Gagnon, P; Gaidot, A; Ganel, O; Gary, J W; Gascon, J; Gascon-Shotkin, S M; Gaycken, G; Geddes, N I; Geich-Gimbel, C; Gensler, S W; Gentit, F X; Geralis, T; Giacomelli, G; Giacomelli, P; Giacomelli, R; Gibson, V; Gibson, W R; Gillies, James D; Gingrich, D M; Giunta, M; Glenzinski, D A; Goldberg, J; Goodrick, M J; Gorn, W; Graham, K; Grandi, C; Grant, F C; Gross, E; Grunhaus, Jacob; Gruwé, M; Günther, P O; Sen-Gupta, A; Hagemann, J; Hajdu, C; Hamann, M; Hanson, G G; Hansroul, M; Hapke, M; Harder, K; Harel, A; Hargrove, C K; Harin-Dirac, M; Harrison, P F; Hart, P A; Hartmann, C; Hattersley, P M; Hauschild, M; Hawkes, C M; Hawkings, R; Heflin, E; Hemingway, R J; Hensel, C; Herten, G; Heuer, R D; Hill, J C; Hillier, S J; Hilse, T; Hinshaw, D A; Ho, C; Hoare, J; Hobbs, J D; Hobson, P R; Hochman, D; Höcker, Andreas; Hoffman, K; Holl, B; Homer, R J; Honma, A K; Horváth, D; Hossain, K R; Howard, R; Howarth, C P; Hüntemeyer, P; Hughes-Jones, R E; Humbert, R; Igo-Kemenes, P; Ihssen, H; Imrie, D C; Ingram, M R; Ishii, K; Jacob, F R; Janissen, A C; Jawahery, A; Jeffreys, P W; Jeremie, H; Jimack, M; Jobes, M; Joly, A; Jones, C R; Jones, G; Jones, M; Jost, U; Jovanovic, P; Jui, C; Kanaya, N; Kanzaki, J; Karapetian, G V; Karlen, D; Kartvelishvili, V G; Kawagoe, K; Kawamoto, T; Keeler, R K; Kellogg, R G; Kennedy, B W; Kim, D H; King, B J; Kirk, J; Klein, K; Kleinwort, C; Klem, D E; Klier, A; Kluth, S; Kobayashi, T; Kobel, M; Köpke, L; Koetke, D S; Kokott, T P; Komamiya, S; Kormos, L; Kowalewski, R V; Kramer, T; Kral, J F; Kress, T; Kreutzmann, H; Krieger, P; Von Krogh, J; Kroll, J; Krop, D; Krüger, K; Kühl, T; Kupper, M; Kuwano, M; Kyberd, P; Lafferty, G D; Lafoux, H; Lahmann, R; Lai, W P; Lamarche, F; Landsman, H; Lanske, D; Larson, W J; Lauber, J; Lautenschlager, S R; Lawson, I; Layter, J G; Lazic, D; Le Dû, P; Leblanc, P; Lee, A M; Lefebvre, E; Leins, A; Lellouch, D; Lennert, P; Leroy, C; Lessard, L; Letts, J; Levegrün, S; Levinson, L; Lewis, C; Liebisch, R; Lillich, J; Littlewood, C; Lloyd, A W; Lloyd, S L; Loebinger, F K; Long, G D; Lorah, J M; Lorazo, B; Losty, Michael J; Lou, X C; Lü, J; Ludwig, A; Ludwig, J; Luig, A; Macchiolo, A; MacPherson, A; Mader, W; Mättig, P; Malik, A; Mannelli, M; Marcellini, S; Marchant, T E; Maringer, G; Markus, C; Martin, A J; Martínez, G; Masetti, G; Mashimo, T; Matthews, W; Maur, U; McDonald, W J; McGowan, R F; McKenna, J; McKigney, E A; McMahon, T J; McNab, A I; McNutt, J R; McPherson, A C; McPherson, R A; Meijers, F; Méndez-Lorenzo, P; Menges, W; Menke, S; Menszner, D; Merritt, F S; Mes, H; Meyer, J; Meyer, N; Michelini, A; Middleton, R P; Mihara, S; Mikenberg, G; Mildenberger, J; Miller, D J; Milstene, C; Mir, R; Moed, S; Mohr, W; Moisan, C; Montanari, A; Mori, T; Moss, M W; Mouthuy, T; Murphy, P G; Mutter, A; Nagai, K; Nakamura, I; Nanjo, H; Neal, H A; Nellen, B; Nguyen, H H; Nijjhar, B; Nisius, R; Nozaki, M; Oakham, F G; Odorici, F; Ogg, M; Ögren, H O; Oh, A; Oh, H; Okpara, A; Oldershaw, N J; Omori, T; O'Neale, S W; O'Neill, B P; Oram, C J; Oreglia, M J; Orito, S; Pahl, C; Pálinkás, J; Palmonari, F; Pansart, J P; Panzer-Steindel, B; Paschievici, P; Pásztor, G; Pater, J R; Patrick, G N; Pawley, S J; Paz-Jaoshvili, N; Pearce, M J; Petzold, S; Pfeifenschneider, P; Pfister, P; Pilcher, J E; Pinfold, J L; Pitman, D; Plane, D E; Poffenberger, P R; Poli, B; Polok, J; Pooth, O; Posthaus, A; Pouladdej, A; del Pozo, L A; Prebys, E; Pritchard, T W; Przybycien, M B; Przysiezniak, H; Quadt, A; Rabbertz, K; Raith, B; Redmond, M W; Rees, D L; Rembser, C; Renkel, P; Richards, G E; Rick, H; Rigby, D; Robins, S A; Robinson, D; Rodning, N; Rollnik, A; Roney, J M; Rooke, A M; Ros, E; Rosati, S; Roscoe, K; Rossberg, S; Rossi, A M; Rosvick, M; Routenburg, P; Rozen, Y; Runge, K; Runólfsson, O; Ruppel, U; Rust, D R; Rylko, R; Sachs, K; Saeki, T; Sahr, O; Sanghera, S; Sarkisyan-Grinbaum, E; Sasaki, M; Sbarra, C; Schaile, A D; Schaile, O; Schappert, W; Scharf, F; Scharff-Hansen, P; Schenk, P; Schieck, J; von der Schmitt, H; Schmitt, S; Schörner-Sadenius, T; Schreiber, S; Schröder, M; Schütz, P; Schultz-Coulon, H C; Schulz, M; Schumacher, M; Schwarz, J; Schwick, C; Scott, W G; Settles, M; Seuster, R; Shears, T G; Shen, B C; Shepherd-Themistocleous, C H; Sherwood, P; Shypit, R; Simon, A; Singh, P; Siroli, G P; Sittler, A; Skillman, A; Skuja, A; Smith, A M; Smith, T J; Snow, G A; Sobie, R J; Söldner-Rembold, S; Spagnolo, S; Spanó, F; Springer, R W; Sproston, M; Starks, M; Steiert, M; Stephens, K; Steuerer, J; Stier, H E; Stockhausen, B; Stoll, K; Ströhmer, R; Strom, D; Strumia, F; Stumpf, L; Surrow, B; Szymanski, P; Tafirout, R; Takeda, H; Takeshita, T; Talbot, S D; Tanaka, S; Taras, P; Tarem, S; Tasevsky, M; Taylor, R J; Tecchio, M; Tesch, N; Teuscher, R; Thackray, N J; Thiergen, M; Thomson, M A; Von Törne, E; Towers, S; Toya, D; Trócsányi, Z L; Tran, P; Trefzger, T; Tresilian, N J; Trigger, I; Tscheulin, M; Tsukamoto, T; Tsur, E; Turcot, A S; Turner-Watson, M F; Tysarczyk-Niemeyer, G; Ueda, I; Ujvári, B; Utzat, P; Vachon, B; Van den Plas, D; Van Kooten, R; VanDalen, G J; Vannerem, P; Vasseur, G; Vertesi, R; Verzocchi, M; Vikas, P; Vincter, M G; Virtue, C J; Vokurka, E H; Vollmer, C F; Voss, H; Vossebeld, Joost Herman; Wäckerle, F; Wagner, A; Wagner, D L; Wahl, C; Walker, J P; Waller, D; Ward, C P; Ward, D R; Watkins, P M; Watson, A T; Watson, N K; Weber, P; Weisz, S; Wells, P S; Wengler, T; Wermes, N; Wetterling, D; Weymann, M; Whalley, M A; White, J S; Wilkens, B; Wilson, J A; Wilson, G W; Wingerter, Isabelle; Winterer, V H; Wood, N C; Wotton, S; Wyatt, T R; Yaari, R; Yamashita, S; Yang, Y; Yeaman, A; Yekutieli, G; Yurko, M; Zacek, V; Zacharov, I E; Zer-Zion, D; Zeuner, W; Zivkovic, L; Zorn, G T; Abe, Kenji; Abe, Koya; Abe, T; Abt, I; Acton, P D; Adam, I; Agnew, G; Akagi, T; Akimoto, H; Allen, N J; Ash, W W; Aston, D; Bacchetta, N; Baird, K G; Baltay, C; Band, H R; Barakat, M B; Baranko, G J; Bardon, O; Barklow, T L; Bashindzhagian, G L; Bauer, J M; Bazarko, A O; Bean, A; Bellodi, G; Ben-David, R; Berger, R; Bienz, T; Bilei, G M; Bisello, D; Blaylock, G; Bogart, J R; Bolen, B; Bolton, T; Bower, G R; Brau, J E; Breidenbach, M; Bugg, W M; Burke, D; Burnett, T H; Burrows, P N; Busza, W; Calcaterra, A; Caldwell, D O; Camanzi, B; Carpinelli, M; Cassell, R; Castaldi, R; Castro, A; Cavalli-Sforza, M; Chadwick, George B; Chou, A; Church, E; Claus, R; Cohn, H O; Coller, J A; Convery, M R; Cook, V; Cotton, R; Cowan, R F; Coyne, D G; Crawford, G; de Oliveira, A; Damerell, C J S; Daoudi, M; Dasu, S; De Groot, N; De Sangro, R; De Simone, P; De Simone, S; Dervan, P J; Dima, M; Dong, D N; Doser, Michael; Du, P Y C; Dubois, R; Duboscq, J E; Eisenstein, B I; Elia, R; Erdos, E; Erofeeva, I; Eschenburg, V; Etzion, E; Fahey, S; Falciai, D; Fan, C; Fernández, J P; Fero, M J; Flood, K; Frey, R; Friedman, Jerome Isaac; Furuno, K; Garwin, E L; Gillman, T; Gladding, G; Hallewell, G D; Hart, E L; Hasegawa, Y; Hasuko, K; Hedges, S; Hertzbach, S S; Hildreth, M D; Hitlin, D G; Honma, A; Huber, J S; Huffer, M E; Hughes, E W; Huynh, X; Hwang, H; Iwasaki, M; Iwasaki, Y; Izen, J M; Jackson, D J; Jacques, P; Jaros, J A; Jiang, Z Y; Johnson, A S; Johnson, J R; Johnson, R A; Junk, T R; Kajikawa, R; Kalelkar, M; Kamyshkov, Yu A; Kang, H J; Karliner, I; Kawahara, H; Kelsey, M H; Kendall, H W; Kim, Y D; King, M; King, R; Kofler, R R; Krishna, N M; Kwon, Y; Labs, J F; Kroeger, R S; Langston, M; Lath, A; Lauber, J A; Leith, D W G S; Lia, V; Lin, C; Liu, M X; Loreti, M; Lu, A; Lynch, H L; Ma, J; Mancinelli, G; Manly, S; Mantovani, G C; Markiewicz, T W; Maruyama, T; Masuda, H; Mazzucato, E; McGowan, J F; McKemey, A K; Meadows, B T; Messner, R; Mockett, P M; Moffeit, K C; Moore, T B; Morii, M; Mours, B; Müller, D; Müller, G; Murzin, V; Nagamine, T; Narita, S; Nauenberg, U; Neal, H; Nesom, G; Nussbaum, M; Ohnishi, Y; Oishi, N; Onoprienko, D; Osborne, L S; Panvini, R S; Park, C H; Park, H; Pavel, T J; Peruzzi, I; Pescara, L; Piccolo, M; Piemontese, L; Pieroni, E; Pitts, K T; Plano, R J; Prepost, R; Prescott, C Y; Punkar, G; Quigley, J; Ratcliff, B N; Reeves, K; Reeves, T W; Reidy, J; Reinertsen, P L; Rensing, P E; Rochester, L S; Rowson, P C; Russell, J J; Saxton, O H; Schalk, T; Schindler, R H; Schneekloth, U; Schumm, B A; Schwiening, J; Seiden, A; Sen, S; Serbo, V V; Shaevitz, M H; Shank, J T; Shapiro, G; Sherden, D J; Shmakov, K D; Simopoulos, C; Sinev, N B; Smith, S R; Smy, M B; Snyder, J A; Sokoloff, M D; Stängle, H; Stahl, A; Stamer, P; Steiner, H; Steiner, R; Strauss, M G; Su, D; Suekane, F; Sugiyama, A; Suzuki, A; Suzuki, S; Swartz, M; Szumilo, A; Takahashi, T; Taylor, F E; Thaler, J J; Thom, J; Torrence, E; Trandafir, A I; Turk, J D; Usher, T; Vavra, J; Vella, E; Venuti, J P; Verdier, R; Wagner, S R; Waite, A P; Walston, S; Wang, J; Watts, S J; Weidemann, A W; Weiss, E R; Whitaker, J S; White, S L; Wickens, F J; Williams, D A; Williams, D C; Williams, S H; Willocq, S; Wilson, R J; Wisniewski, W J; Wittlin, J L; Woods, M; Word, G B; Wright, T R; Wyss, J; Yamamoto, R K; Yang, X Q; Yashima, J; Yellin, S J; Young, C C; Yuta, H; Zapalac, G; Zdarko, R W; Zeitlin, C; Zhou, J

    2006-01-01

    We report on the final electroweak measurements performed with data taken at the Z resonance by the experiments operating at the electron-positron colliders SLC and LEP. The data consist of 17 million Z decays accumulated by the ALEPH, DELPHI, L3 and OPAL experiments at LEP, and 600 thousand Z decays by the SLD experiment using a polarised beam at SLC. The measurements include cross-sections, forward-backward asymmetries and polarised asymmetries. The mass and width of the Z boson, $MZ$ and $GZ$, and its couplings to fermions, for example the $ ho$ parameter and the effective electroweak mixing angle for leptons, are precisely measured: egin{eqnarray*} MZ & = & 91.1875 pm 0.0021~GeV \\ GZ & = & 2.4952 pm 0.0023~GeV \\ ho_ell & = & 1.0050 pm 0.0010 \\ swsqeffl & =& 0.23153 pm 0.00016 ,. end{eqnarray*} The number of light neutrino species is determined to be $2.9840pm0.0082$, in agreement with the three observed generations of fundamental fermions. The results are compared to the pr...

  4. Are torque values of preadjusted brackets precise?

    Directory of Open Access Journals (Sweden)

    Alessandra Motta Streva

    Full Text Available OBJECTIVE: The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS: Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli and Ortho Organizers. The torque angle, established by reference points and lines, was measured by an operator using an optical microscope coupled to a computer. The values were compared to those established by the MBT prescription. RESULTS: The results showed that for the maxillary canine brackets, only the Morelli torque (-3.33º presented statistically significant difference from the proposed values (-7º. For the mandibular canines, American Orthodontics (-6.34º and Ortho Organizers (-6.25º presented statistically significant differences from the standards (-6º. Comparing the brands, Morelli presented statistically significant differences in comparison with all the other brands for maxillary canine brackets. For the mandibular canine brackets, there was no statistically significant difference between the brands. CONCLUSIONS: There are significant variations in torque values of some of the brackets assessed, which would clinically compromise the buccolingual positioning of the tooth at the end of orthodontic treatment.

  5. Precision measurement of $D$ meson mass differences

    CERN Document Server

    INSPIRE-00258707; Abellan Beteta, C; Adeva, B; Adinolfi, M; Adrover, C; Affolder, A; Ajaltouni, Z; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves Jr, A A; Amato, S; Amerio, S; Amhis, Y; Anderlini, L; Anderson, J; Andreassen, R; Appleby, R B; Aquines Gutierrez, O; Archilli, F; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Bachmann, S; Back, J J; Baesso, C; Balagura, V; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Bauer, Th; Bay, A; Beddow, J; Bedeschi, F; Bediaga, I; Belogurov, S; Belous, K; Belyaev, I; Ben-Haim, E; Benayoun, M; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bettler, M -O; van Beuzekom, M; Bien, A; Bifani, S; Bird, T; Bizzeti, A; Bjørnstad, P M; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borgia, A; Bowcock, T J V; Bowen, E; Bozzi, C; Brambach, T; van den Brand, J; Bressieux, J; Brett, D; Britsch, M; Britton, T; Brook, N H; Brown, H; Burducea, I; Bursche, A; Busetto, G; Buytaert, J; Cadeddu, S; Callot, O; Calvi, M; Calvo Gomez, M; Camboni, A; Campana, P; Campora Perez, D; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carranza-Mejia, H; Carson, L; Carvalho Akiba, K; Casse, G; Cattaneo, M; Cauet, Ch; Charles, M; Charpentier, Ph; Chen, P; Chiapolini, N; Chrzaszcz, M; Ciba, K; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coca, C; Coco, V; Cogan, J; Cogneras, E; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Couturier, B; Cowan, G A; Craik, D C; Cunliffe, S; Currie, R; D'Ambrosio, C; David, P; David, P N Y; Davis, A; De Bonis, I; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Silva, W; De Simone, P; Decamp, D; Deckenhoff, M; Del Buono, L; Derkach, D; Deschamps, O; Dettori, F; Di Canto, A; Dijkstra, H; Dogaru, M; Donleavy, S; Dordei, F; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dupertuis, F; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; van Eijk, D; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Elsby, D; Falabella, A; Färber, C; Fardell, G; Farinelli, C; Farry, S; Fave, V; Ferguson, D; Fernandez Albor, V; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fitzpatrick, C; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Furcas, S; Furfaro, E; Gallas Torreira, A; Galli, D; Gandelman, M; Gandini, P; Gao, Y; Garofoli, J; Garosi, P; Garra Tico, J; Garrido, L; Gaspar, C; Gauld, R; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gibson, V; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gordon, H; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hampson, T; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; Hartmann, T; He, J; Heijne, V; Hennessy, K; Henrard, P; Hernando Morata, J A; van Herwijnen, E; Hicks, E; Hill, D; Hoballah, M; Hombach, C; Hopchev, P; Hulsbergen, W; Hunt, P; Huse, T; Hussain, N; Hutchcroft, D; Hynds, D; Iakovenko, V; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jans, E; Jaton, P; Jing, F; John, M; Johnson, D; Jones, C R; Jost, B; Kaballo, M; Kandybei, S; Karacson, M; Karbach, T M; Kenyon, I R; Kerzel, U; Ketel, T; Keune, A; Khanji, B; Kochebina, O; Komarov, I; Koopman, R F; Koppenburg, P; Korolev, M; Kozlinskiy, A; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Kucharczyk, M; Kudryavtsev, V; Kvaratskheliya, T; La Thi, V N; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lambert, R W; Lanciotti, E; Lanfranchi, G; Langenbruch, C; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J -P; Lefèvre, R; Leflat, A; Lefrançois, J; Leo, S; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Li Gioi, L; Liles, M; Lindner, R; Linn, C; Liu, B; Liu, G; Lohn, S; Longstaff, I; Lopes, J H; Lopez Asamar, E; Lopez-March, N; Lu, H; Lucchesi, D; Luisier, J; Luo, H; Machefert, F; Machikhiliyan, I V; Maciuc, F; Maev, O; Malde, S; Manca, G; Mancinelli, G; Marconi, U; Märki, R; Marks, J; Martellotti, G; Martens, A; Martin, L; Martín Sánchez, A; Martinelli, M; Martinez Santos, D; Martins Tostes, D; Massafferri, A; Matev, R; Mathe, Z; Matteuzzi, C; Maurice, E; Mazurov, A; McCarthy, J; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Merk, M; Milanes, D A; Minard, M -N; Molina Rodriguez, J; Monteil, S; Moran, D; Morawski, P; Morello, M J; Mountain, R; Mous, I; Muheim, F; Müller, K; Muresan, R; Muryn, B; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nasteva, I; Needham, M; Neufeld, N; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Nicol, M; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Nomerotski, A; Novoselov, A; Oblakowska-Mucha, A; Obraztsov, V; Oggero, S; Ogilvy, S; Okhrimenko, O; Oldeman, R; Orlandea, M; Otalora Goicochea, J M; Owen, P; Oyanguren, A; Pal, B K; Palano, A; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Parkes, C; Parkinson, C J; Passaleva, G; Patel, G D; Patel, M; Patrick, G N; Patrignani, C; Pavel-Nicorescu, C; Pazos Alvarez, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perego, D L; Perez Trigo, E; Pérez-Calero Yzquierdo, A; Perret, P; Perrin-Terrin, M; Pessina, G; Petridis, K; Petrolini, A; Phan, A; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Playfer, S; Plo Casasus, M; Polci, F; Polok, G; Poluektov, A; Polycarpo, E; Popov, D; Popovici, B; Potterat, C; Powell, A; Prisciandaro, J; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Rademacker, J H; Rakotomiaramanana, B; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redford, S; Reid, M M; dos Reis, A C; Ricciardi, S; Richards, A; Rinnert, K; Rives Molina, V; Roa Romero, D A; Robbe, P; Rodrigues, E; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Rouvinet, J; Ruf, T; Ruffini, F; Ruiz, H; Ruiz Valls, P; Sabatino, G; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salzmann, C; Sanmartin Sedes, B; Sannino, M; Santacesaria, R; Santamarina Rios, C; Santovetti, E; Sapunov, M; Sarti, A; Satriano, C; Satta, A; Savrie, M; Savrina, D; Schaack, P; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmidt, B; Schneider, O; Schopper, A; Schune, M -H; Schwemmer, R; Sciascia, B; Sciubba, A; Seco, M; Semennikov, A; Senderowska, K; Sepp, I; Serra, N; Serrano, J; Seyfert, P; Shapkin, M; Shapoval, I; Shatalov, P; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, O; Shevchenko, V; Shires, A; Silva Coutinho, R; Skwarnicki, T; Smith, N A; Smith, E; Smith, M; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Sparkes, A; Spradlin, P; Stagni, F; Stahl, S; Steinkamp, O; Stoica, S; Stone, S; Storaci, B; Straticiuc, M; Straumann, U; Subbiah, V K; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Teklishyn, M; Teodorescu, E; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Tolk, S; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Tran, M T; Tresch, M; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ubeda Garcia, M; Ukleja, A; Urner, D; Uwer, U; Vagnoni, V; Valenti, G; Vazquez Gomez, R; Vazquez Regueiro, P; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; Voss, H; Waldi, R; Wallace, R; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Webber, A D; Websdale, D; Whitehead, M; Wicht, J; Wiechczynski, J; Wiedner, D; Wiggers, L; Wilkinson, G; Williams, M P; Williams, M; Wilson, F F; Wishahi, J; Witek, M; Wotton, S A; Wright, S; Wu, S; Wyllie, K; Xie, Y; Xing, F; Xing, Z; Yang, Z; Young, R; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, F; Zhang, L; Zhang, W C; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zvyagin, A

    2013-01-01

    Using three- and four-body decays of $D$ mesons produced in semileptonic $b$-hadron decays, precision measurements of $D$ meson mass differences are made together with a measurement of the $D^{0}$ mass. The measurements are based on a dataset corresponding to an integrated luminosity of 1.0 fb$^{-1}$ collected in $pp$ collisions at 7~TeV. Using the decay $D^0 \\rightarrow K^{+} K^{-} K^{-} \\pi^{+}$, the $D^0$ mass is measured to be \\begin{alignat*}{3} M(D^0) \\phantom{ghd} &=&~1864.75 \\pm 0.15 \\,({\\rm stat}) \\pm 0.11 \\,({\\rm syst}) \\, \\textrm{MeV}/c^2. \\end{alignat*} The mass differences \\begin{alignat*}{3} M(D^{+}) - M(D^{0}) &=& 4.76 \\pm 0.12 \\,({\\rm stat}) \\pm 0.07 \\,({\\rm syst}) \\, \\textrm{MeV}/c^2, \\\\ M(D^{+}_s) - M(D^{+}) &=& \\phantom{00}98.68 \\pm 0.03 \\,({\\rm stat}) \\pm 0.04 \\,({\\rm syst}) \\, \\textrm{MeV}/c^2 \\end{alignat*} are measured using the $D^0 \\rightarrow K^{+} K^{-} \\pi^{+} \\pi^{-}$ and $D^{+}_{(s)} \\rightarrow K^{+}K^{-} \\pi^{+}$ modes.

  6. Precision holography for non-conformal branes

    Science.gov (United States)

    Kanitscheider, Ingmar; Skenderis, Kostas; Taylor, Marika

    2008-09-01

    We set up precision holography for the non-conformal branes preserving 16 supersymmetries. The near-horizon limit of all such p-brane solutions with p tensor properly defines the notion of mass for backgrounds with such asymptotics. The analysis is done both in the original formulation of the method and also using a radial Hamiltonian analysis. The latter formulation exhibits most clearly the existence of an underlying generalized conformal structure. In the cases of Dp-branes, the corresponding dual boundary theory, the maximally supersymmetric Yang-Mills theory SYMp+1, indeed exhibits the generalized conformal structure found at strong coupling. We compute the holographic 2-point functions of the stress energy tensor and gluon operator and show they satisfy the expected Ward identities and the constraints of generalized conformal structure. The holographic results are also manifestly compatible with the M-theory uplift, with the asymptotic solutions, counterterms, one and two point functions etc. of the IIA F1 and D4 appropriately descending from those of M2 and M5 branes, respectively. We present a few applications including the computation of condensates in Witten's model of holographic YM{}4 theory.

  7. Toward precision holography with supersymmetric Wilson loops

    Energy Technology Data Exchange (ETDEWEB)

    Faraggi, Alberto [Instituto de Física, Pontificia Universidad Católica de Chile,Casilla 306, Santiago (Chile); Zayas, Leopoldo A. Pando [The Abdus Salam International Centre for Theoretical Physics,Strada Costiera 11, 34014 Trieste (Italy); Michigan Center for Theoretical Physics, Department of Physics,University of Michigan, Ann Arbor, MI 48109 (United States); Silva, Guillermo A. [Instituto de Física de La Plata - CONICET & Departamento de Física - UNLP,C.C. 67, 1900 La Plata (Argentina); Trancanelli, Diego [Institute of Physics, University of São Paulo,05314-970 São Paulo (Brazil)

    2016-04-11

    We consider certain 1/4 BPS Wilson loop operators in SU(N)N=4 supersymmetric Yang-Mills theory, whose expectation value can be computed exactly via supersymmetric localization. Holographically, these operators are mapped to fundamental strings in AdS{sub 5}×S{sup 5}. The string on-shell action reproduces the large N and large coupling limit of the gauge theory expectation value and, according to the AdS/CFT correspondence, there should also be a precise match between subleading corrections to these limits. We perform a test of such match at next-to-leading order in string theory, by deriving the spectrum of quantum fluctuations around the classical string solution and by computing the corresponding 1-loop effective action. We discuss in detail the supermultiplet structure of the fluctuations. To remove a possible source of ambiguity in the ghost zero mode measure, we compare the 1/4 BPS configuration with the 1/2 BPS one, dual to a circular Wilson loop. We find a discrepancy between the string theory result and the gauge theory prediction, confirming a previous result in the literature. We are able to track the modes from which this discrepancy originates, as well as the modes that by themselves would give the expected result.

  8. Precise Orbit Determination of QZS-1

    Science.gov (United States)

    Hugentobler, U.; Steigenberger, P.; Rodriguez-Solano, C.; Hauschild, A.

    2011-12-01

    QZS-1, the first satellite of the Japanese Quasi Zenith Satellite System (QZSS) was launched in September 2010. Transmission of the standard codes started in December 2010 and the satellite was declared healthy in June 2011. Five stations of the COoperative Network for GIOVE Observation (CONGO) were upgraded to provide QZSS tracking capability. These five stations provide the basis for the precise orbit determination (POD) of the QZS-1 spacecraft. The stability and consistency of different orbital arc lengths is analyzed based on orbit fit residuals, day boundary discontinuities, and Satellite Laser Ranging residuals. As QZS-1 simultaneously transmits navigation signals on three frequencies in the L1, L2, and L5 band, different ionosphere-free linear combinations can be formed. The differences of the orbits computed from these different observables (ionosphere-free linear combination of L1/L2 and L1/L5) as well as the stability of the differential code biases estimated within the POD are studied. Finally, results of the attitude determination based on the navigation signal transmission from two different antennas onboard QZS-1 are presented.

  9. Charting a Course for Precision Oncology.

    Science.gov (United States)

    Kusnezov, D; Paragas, J

    2017-05-01

    The fields of science have undergone dramatic reorganizations as they have come to terms with the realities of the growing complexities of their problem set, the costs, and the breadth of skills needed to make major progress. A field such as particle physics transformed from principal investigator-driven research supported by an electron synchrotron in the basement of your physics building in the 1950s, to regional centers when costs became prohibitive to refresh technology everywhere, driving larger teams of scientists to cooperate in the 1970s, to international centers where multinational teams work together to achieve progress. The 2013 Nobel Prize winning discovery of the Higgs boson would have been unlikely without such team science. Other fields such as the computational sciences are well on their way through such a transformation. Today, we see precision medicine as a field that will need to come to terms with new organizational principles in order to make major progress, including everyone from individual medical researchers to pharma. Interestingly, the Cancer Moonshot has helped move thinking in that direction for part of the community and now the initiative has been transformed into law. Published 2017. This article is a U.S. Government work and is in the public domain in the USA.

  10. Design of precision position adjustable scoop

    International Nuclear Information System (INIS)

    Li Zhili; Zhang Kai; Dong Jinping

    2014-01-01

    In isotopes separation technologies, the centrifuge method has been the most popular technology now. Separation performance of centrifugal machines is greatly influenced by the flow field in the centrifugal machines. And the position of scoops in the centrifuges has a significant influence on the flow field. To obtain a better flow field characteristic and find the best position of scoops in the centrifuges, a position adjustable scoop system was studied. A micro stage and a linear encoder were used in the system to improve the position accuracy of the scoop. Eddy current sensors had been used in a position calibration measurement. The measurement result showed the sensitivity and stability of the position system could meet the performance expectation. But as the driving mean, the steel wire and pulley limit the control precision. On the basis of this scheme, an ultrasonic motor was used as driving mean. Experimental results showed the control accuracy was improved. This scheme laid a foundation to obtain internal flow field parameters of centrifuge and get the optimal feeding tube position. (authors)

  11. Differential Phase Detector for Precise Phase Alignment

    CERN Document Server

    Olexa, Jakub

    2016-01-01

    This paper presents a differential phase detector circuit, whose phase-to-voltage characteristic has an extremum when its two input signals are exactly in phase. In this condition all its digital signals are of 50 % duty cycle so that the circuit characteristic does not have a dead zone. This feature allows a precise indication of the zero-phase condition, which is independent of the detector power supply and the offset of its ADC readout. Such a detector is used for a phase alignment of two reference clock signals with frequency about 11 kHz in front-ends processing signals from beam position monitors of the Large Hadron Collider (LHC) at CERN. The detector output voltage is digitized with a 24-bit ADC at the rate of the reference signals. The resulting samples are processed in the front-end FPGA and transmitted to the control system using an Ethernet data stream. After a detailed description of the differential phase detector its performance is demonstrated with laboratory measurements. The results show tha...

  12. Precision Cardiovascular Medicine: State of Genetic Testing.

    Science.gov (United States)

    Giudicessi, John R; Kullo, Iftikhar J; Ackerman, Michael J

    2017-04-01

    In the 15 years following the release of the first complete human genome sequences, our understanding of rare and common genetic variation as determinants of cardiovascular disease susceptibility, prognosis, and therapeutic response has grown exponentially. As such, the use of genomics to enhance the care of patients with cardiovascular diseases has garnered increased attention from clinicians, researchers, and regulatory agencies eager to realize the promise of precision genomic medicine. However, owing to a large burden of "complex" common diseases, emphasis on evidence-based practice, and a degree of unfamiliarity/discomfort with the language of genomic medicine, the development and implementation of genomics-guided approaches designed to further individualize the clinical management of a variety of cardiovascular disorders remains a challenge. In this review, we detail a practical approach to genetic testing initiation and interpretation as well as review the current state of cardiovascular genetic and pharmacogenomic testing in the context of relevant society and regulatory agency recommendations/guidelines. Copyright © 2017 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  13. Precision Laser Annealing of Focal Plane Arrays

    Energy Technology Data Exchange (ETDEWEB)

    Bender, Daniel A. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); DeRose, Christopher [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Starbuck, Andrew Lea [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Verley, Jason C. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Jenkins, Mark W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-09-01

    We present results from laser annealing experiments in Si using a passively Q-switched Nd:YAG microlaser. Exposure with laser at fluence values above the damage threshold of commercially available photodiodes results in electrical damage (as measured by an increase in photodiode dark current). We show that increasing the laser fluence to values in excess of the damage threshold can result in annealing of a damage site and a reduction in detector dark current by as much as 100x in some cases. A still further increase in fluence results in irreparable damage. Thus we demonstrate the presence of a laser annealing window over which performance of damaged detectors can be at least partially reconstituted. Moreover dark current reduction is observed over the entire operating range of the diode indicating that device performance has been improved for all values of reverse bias voltage. Additionally, we will present results of laser annealing in Si waveguides. By exposing a small (<10 um) length of a Si waveguide to an annealing laser pulse, the longitudinal phase of light acquired in propagating through the waveguide can be modified with high precision, <15 milliradian per laser pulse. Phase tuning by 180 degrees is exhibited with multiple exposures to one arm of a Mach-Zehnder interferometer at fluence values below the morphological damage threshold of an etched Si waveguide. No reduction in optical transmission at 1550 nm was found after 220 annealing laser shots. Modeling results for laser annealing in Si are also presented.

  14. Advances in precision mirror figure metrology (abstract)

    International Nuclear Information System (INIS)

    Takacs, P.Z.; Furenlid, K.; Church, E.L.

    1992-01-01

    New developments in optical measurement techniques have made it possible to test the surface quality on grazing incidence optics with extreme precision and accuracy. An instrument developed at Brookhaven, the Long Trace Profiler (LTP), measures the figure of large (up to 1 m long) cylindrical aspheres with nanometer accuracy. The LTP optical system is based around a common-path interferometer design belonging to the class of slope measuring interferometers and, as such, it is very robust, stable, and vibration insensitive. A unique error correction technique removes the effect of tilt errors in the optical head as it traverses the air bearing, thus allowing one to accurately measure the absolute surface profile and radius of curvature. This is of critical importance to the manufacture of long-radius spherical optics used in high-resolution soft x-ray monochromators and in the testing of mirror bending systems. This talk will review the principle of operation of the LTP, probe the factors limiting the performance of the system, and will examine the current state of the art in synchrotron radiation mirror manufacturing quality (as viewed by our metrology techniques). This research was supported by the U.S. Department of Energy Contract No. DE-AC02-76CH00016

  15. LHC Power Converters: A Precision Game

    CERN Multimedia

    2001-01-01

    The LHC test-bed, String 2, is close to commissioning and one important element to get a first chance to prove what it can do is the power converter system. In String 2 there are 16 converters, in the full LHC there will be almost 1800. This article takes a look at what is so special about the power converters for the LHC. The 13 000 Amps power converters with the watercooled cables going to the String 2 feedboxes. The LHC's superconducting magnets will be the pinnacle of high technology. But to work, they'll need the help of high-precision power converters to supply them with extremely stable DC current. Perfection will be the name of the game, with an accuracy of just 1-2 parts per million (ppm) required. LEP, for the sake of comparison, could live with 10-20 ppm. The LHC's power converters will be very different from those of LEP or the SPS since the new accelerator's magnets are mostly superconducting. That means that they require much higher currents at a lower voltage since superconductors have no re...

  16. Precision machining of advanced materials with waterjets

    Science.gov (United States)

    Liu, H. T.

    2017-01-01

    Recent advances in abrasive waterjet technology have elevated to the state that it often competes on equal footing with lasers and EDM for precision machining. Under the support of a National Science Foundation SBIR Phase II grant, OMAX has developed and commercialized micro abrasive water technology that is incorporated into a MicroMAX® JetMa- chining® Center. Waterjet technology, combined both abrasive waterjet and micro abrasive waterjet technology, is capable of machining most materials from macro to micro scales for a wide range of part size and thickness. Waterjet technology has technological and manufacturing merits that cannot be matched by most existing tools. As a cold cutting tool that creates no heat-affected zone, for example, waterjet cuts much faster than wire EDM and laser when measures to minimize a heat-affected zone are taken into account. In addition, waterjet is material independent; it cuts materials that cannot be cut or are difficult to cut otherwise. The versatility of waterjet has also demonstrated machining simulated nanomaterials with large gradients of material properties from metal, nonmetal, to anything in between. This paper presents waterjet-machined samples made of a wide range of advanced materials from macro to micro scales.

  17. High-Precision Phenotyping of Grape Bunch Architecture Using Fast 3D Sensor and Automation.

    Science.gov (United States)

    Rist, Florian; Herzog, Katja; Mack, Jenny; Richter, Robert; Steinhage, Volker; Töpfer, Reinhard

    2018-03-02

    Wine growers prefer cultivars with looser bunch architecture because of the decreased risk for bunch rot. As a consequence, grapevine breeders have to select seedlings and new cultivars with regard to appropriate bunch traits. Bunch architecture is a mosaic of different single traits which makes phenotyping labor-intensive and time-consuming. In the present study, a fast and high-precision phenotyping pipeline was developed. The optical sensor Artec Spider 3D scanner (Artec 3D, L-1466, Luxembourg) was used to generate dense 3D point clouds of grapevine bunches under lab conditions and an automated analysis software called 3D-Bunch-Tool was developed to extract different single 3D bunch traits, i.e., the number of berries, berry diameter, single berry volume, total volume of berries, convex hull volume of grapes, bunch width and bunch length. The method was validated on whole bunches of different grapevine cultivars and phenotypic variable breeding material. Reliable phenotypic data were obtained which show high significant correlations (up to r² = 0.95 for berry number) compared to ground truth data. Moreover, it was shown that the Artec Spider can be used directly in the field where achieved data show comparable precision with regard to the lab application. This non-invasive and non-contact field application facilitates the first high-precision phenotyping pipeline based on 3D bunch traits in large plant sets.

  18. High-Precision Phenotyping of Grape Bunch Architecture Using Fast 3D Sensor and Automation

    Directory of Open Access Journals (Sweden)

    Florian Rist

    2018-03-01

    Full Text Available Wine growers prefer cultivars with looser bunch architecture because of the decreased risk for bunch rot. As a consequence, grapevine breeders have to select seedlings and new cultivars with regard to appropriate bunch traits. Bunch architecture is a mosaic of different single traits which makes phenotyping labor-intensive and time-consuming. In the present study, a fast and high-precision phenotyping pipeline was developed. The optical sensor Artec Spider 3D scanner (Artec 3D, L-1466, Luxembourg was used to generate dense 3D point clouds of grapevine bunches under lab conditions and an automated analysis software called 3D-Bunch-Tool was developed to extract different single 3D bunch traits, i.e., the number of berries, berry diameter, single berry volume, total volume of berries, convex hull volume of grapes, bunch width and bunch length. The method was validated on whole bunches of different grapevine cultivars and phenotypic variable breeding material. Reliable phenotypic data were obtained which show high significant correlations (up to r2 = 0.95 for berry number compared to ground truth data. Moreover, it was shown that the Artec Spider can be used directly in the field where achieved data show comparable precision with regard to the lab application. This non-invasive and non-contact field application facilitates the first high-precision phenotyping pipeline based on 3D bunch traits in large plant sets.

  19. Accelerating Correlated Quantum Chemistry Calculations Using Graphical Processing Units and a Mixed Precision Matrix Multiplication Library.

    Science.gov (United States)

    Olivares-Amaya, Roberto; Watson, Mark A; Edgar, Richard G; Vogt, Leslie; Shao, Yihan; Aspuru-Guzik, Alán

    2010-01-12

    Two new tools for the acceleration of computational chemistry codes using graphical processing units (GPUs) are presented. First, we propose a general black-box approach for the efficient GPU acceleration of matrix-matrix multiplications where the matrix size is too large for the whole computation to be held in the GPU's onboard memory. Second, we show how to improve the accuracy of matrix multiplications when using only single-precision GPU devices by proposing a heterogeneous computing model, whereby single- and double-precision operations are evaluated in a mixed fashion on the GPU and central processing unit, respectively. The utility of the library is illustrated for quantum chemistry with application to the acceleration of resolution-of-the-identity second-order Møller-Plesset perturbation theory calculations for molecules, which we were previously unable to treat. In particular, for the 168-atom valinomycin molecule in a cc-pVDZ basis set, we observed speedups of 13.8, 7.8, and 10.1 times for single-, double- and mixed-precision general matrix multiply (SGEMM, DGEMM, and MGEMM), respectively. The corresponding errors in the correlation energy were reduced from -10.0 to -1.2 kcal mol(-1) for SGEMM and MGEMM, respectively, while higher accuracy can be easily achieved with a different choice of cutoff parameter.

  20. Precision half-life measurement of 11C: The most precise mirror transition F t value

    Science.gov (United States)

    Valverde, A. A.; Brodeur, M.; Ahn, T.; Allen, J.; Bardayan, D. W.; Becchetti, F. D.; Blankstein, D.; Brown, G.; Burdette, D. P.; Frentz, B.; Gilardy, G.; Hall, M. R.; King, S.; Kolata, J. J.; Long, J.; Macon, K. T.; Nelson, A.; O'Malley, P. D.; Skulski, M.; Strauss, S. Y.; Vande Kolk, B.

    2018-03-01

    Background: The precise determination of the F t value in T =1 /2 mixed mirror decays is an important avenue for testing the standard model of the electroweak interaction through the determination of Vu d in nuclear β decays. 11C is an interesting case, as its low mass and small QE C value make it particularly sensitive to violations of the conserved vector current hypothesis. The present dominant source of uncertainty in the 11CF t value is the half-life. Purpose: A high-precision measurement of the 11C half-life was performed, and a new world average half-life was calculated. Method: 11C was created by transfer reactions and separated using the TwinSol facility at the Nuclear Science Laboratory at the University of Notre Dame. It was then implanted into a tantalum foil, and β counting was used to determine the half-life. Results: The new half-life, t1 /2=1220.27 (26 ) s, is consistent with the previous values but significantly more precise. A new world average was calculated, t1/2 world=1220.41 (32 ) s, and a new estimate for the Gamow-Teller to Fermi mixing ratio ρ is presented along with standard model correlation parameters. Conclusions: The new 11C world average half-life allows the calculation of a F tmirror value that is now the most precise value for all superallowed mixed mirror transitions. This gives a strong impetus for an experimental determination of ρ , to allow for the determination of Vu d from this decay.

  1. Subtractive fabrication of ferroelectric thin films with precisely controlled thickness

    Science.gov (United States)

    Ievlev, Anton V.; Chyasnavichyus, Marius; Leonard, Donovan N.; Agar, Joshua C.; Velarde, Gabriel A.; Martin, Lane W.; Kalinin, Sergei V.; Maksymovych, Petro; Ovchinnikova, Olga S.

    2018-04-01

    The ability to control thin-film growth has led to advances in our understanding of fundamental physics as well as to the emergence of novel technologies. However, common thin-film growth techniques introduce a number of limitations related to the concentration of defects on film interfaces and surfaces that limit the scope of systems that can be produced and studied experimentally. Here, we developed an ion-beam based subtractive fabrication process that enables creation and modification of thin films with pre-defined thicknesses. To accomplish this we transformed a multimodal imaging platform that combines time-of-flight secondary ion mass spectrometry with atomic force microscopy to a unique fabrication tool that allows for precise sputtering of the nanometer-thin layers of material. To demonstrate fabrication of thin-films with in situ feedback and control on film thickness and functionality we systematically studied thickness dependence of ferroelectric switching of lead-zirconate-titanate, within a single epitaxial film. Our results demonstrate that through a subtractive film fabrication process we can control the piezoelectric response as a function of film thickness as well as improve on the overall piezoelectric response versus an untreated film.

  2. Compact, Low-power and Precision Timing Photodetector Readout

    International Nuclear Information System (INIS)

    Varner, Gary S.; Ruckman, Larry L.; Schwiening, Jochen; Vavra, Jaroslav

    2011-01-01

    Photodetector readout for next generation high event rate particle identification and single-photon detection requires a digitizer capable of integrated recording of dense arrays of sensor elements with high analog bandwidth (precision timing) and large record depth, in a cost-effective, compact and low-power way. Simply stated, one cannot do better than having a high-fidelity 'oscilloscope on a chip' for every sensor channel. A firs version of the Buffered Large Analog Bandwidth (BLAB1) ASIC has been designed based upon the lessons learned from the development of the Large Analog Bandwidth Recorder and Digitizer with Ordered Readout (LABRADOR) ASIC. While this LABRADOR ASIC has been very successful and forms the readout basis of a generation of new, large-scale radio neutrino detectors, its limited sampling depth is a major drawback. To address this shortcoming, a prototype intended for photodetector readout has been designed and fabricated with 64k deep sampling at multi-GSa/s operation. An evaluation system has been constructed for instrumentation of Time-Of-Propagation (TOP) and focusing DIRC prototypes and test results will be reported.

  3. High-Precision Direct Mass Determination of Unstable Isotopes

    CERN Multimedia

    2002-01-01

    The extension of systematic high-precision measurements of the nuclear mass to nuclei far from the valley of $\\beta$ stability is of great interest in nuclear physics and astrophysics. The mass, or binding energy, is a fundamental gross property and a key input parameter for nuclear matter calculations. It is also a sensitive probe for collective and single-particle effects in nuclear structure. \\\\ \\\\ For such purposes, nuclear masses need to be known to an accuracy of about 10$^{-7}$ (i.e. $\\Delta$M~$\\leq$~10~keV for A~=~100). To resolve a particular mass from its nuclear isomers and isobars, resolving power of 10$^6$ are often required. To achieve this, the ions delivered by the on-line mass separator ISOLDE are confined in a Penning quadrupole trap. This trap is placed in the very homogeneous and stable magnetic field of a superconducting magnet. Here, the cyclotron frequency and hence the mass are determined. \\\\ \\\\ The first measurements using this new technique have been completed for a long chain of Cs ...

  4. Precision of MPX detectors as LHC luminosity monitor

    Energy Technology Data Exchange (ETDEWEB)

    Sopczak, Andre; Ali, Babar; Benes, Petr; Bergmann, Benedikt; Biskup, Bartolomej; Caforio, Davide; Heijne, Erik; Pospisil, Stanislav; Seifert, Frank; Solc, Jaroslav; Suk, Michal; Turecek, Daniel; Vykydal, Zdenek [IEAP CTU in Prague (Czech Republic); Asbah, Nedaa; Leroy, Claude; Soueid, Paul [University of Montreal (Canada); Campbell, Michael; Nessi, Marzio [CERN (Switzerland); Kladiva, Edward [IEP SAS Kosice (Slovakia)

    2015-07-01

    A network consisting of MPX detectors based on Medipix2 silicon pixel devices were originally adapted for measuring the composition and spectral characteristics of the radiation field in the ATLAS experiment and its surroundings. We demonstrate that the MPX network, which consists of 16 MPX detectors, is a self-contained luminosity monitor system. As the MPX detectors are collecting data independently of the ATLAS data-recording chain, they provide independent measurements of the bunch-integrated ATLAS/LHC luminosity. In particular, the MPX detectors close enough to the primary interaction point are used to perform van der Meer calibration scans with good precision. Results from the luminosity monitoring are presented for 2012 data taken at √(s)=8 TeV proton-proton collisions. The characteristics of the LHC luminosity reduction are studied and the effects of beam-beam (burn-off) and beam-gas (single bunch) interactions are evaluated. The variations of the MPX luminosity measurements around the fitted curve lead to a relative uncertainty on the luminosity measurement below 0.3% for one minute time intervals.

  5. Precision glass molding: Toward an optimal fabrication of optical lenses

    Science.gov (United States)

    Zhang, Liangchi; Liu, Weidong

    2017-03-01

    It is costly and time consuming to use machining processes, such as grinding, polishing and lapping, to produce optical glass lenses with complex features. Precision glass molding (PGM) has thus been developed to realize an efficient manufacture of such optical components in a single step. However, PGM faces various technical challenges. For example, a PGM process must be carried out within the super-cooled region of optical glass above its glass transition temperature, in which the material has an unstable non-equilibrium structure. Within a narrow window of allowable temperature variation, the glass viscosity can change from 105 to 1012 Pas due to the kinetic fragility of the super-cooled liquid. This makes a PGM process sensitive to its molding temperature. In addition, because of the structural relaxation in this temperature window, the atomic structure that governs the material properties is strongly dependent on time and thermal history. Such complexity often leads to residual stresses and shape distortion in a lens molded, causing unexpected changes in density and refractive index. This review will discuss some of the central issues in PGM processes and provide a method based on a manufacturing chain consideration from mold material selection, property and deformation characterization of optical glass to process optimization. The realization of such optimization is a necessary step for the Industry 4.0 of PGM.

  6. Precision measurements of electroweak observables with the ATLAS Detector

    CERN Document Server

    Vittori, Camilla; The ATLAS collaboration

    2017-01-01

    Measurements of the Drell-Yan production of W and Z/gamma bosons at the LHC provide a benchmark of our understanding of perturbative QCD and probe the proton structure in a unique way. The ATLAS collaboration measured the di-lepton mass range up to the TeV scale as well as the triple differential cross-section measurement as a function of Mll, dilepton rapidity and cosθ defined in the Collins-Soper frame. This measurement provides sensitivity to the PDFs and the weak mixing angle. The latest results of the ATLAS collaboration will be presented. A second important observable in the electroweak sector is the W boson mass in order to test the overall consistency of the Standard Model. Since the discovery of a Higgs Boson, the the W boson mass is predicted to 7 MeV precision, while the world average of all measurements is 15 MeV, making the improved measurement an important goal. Large samples of leptonic decays of W and Z bosons were collected with efficient single lepton triggers in the 7 TeV data set correspo...

  7. PRECISION POINTING OF IBEX-Lo OBSERVATIONS

    International Nuclear Information System (INIS)

    Hłond, M.; Bzowski, M.; Möbius, E.; Kucharek, H.; Heirtzler, D.; Schwadron, N. A.; Neill, M. E. O'; Clark, G.; Crew, G. B.; Fuselier, S.; McComas, D. J.

    2012-01-01

    Post-launch boresight of the IBEX-Lo instrument on board the Interstellar Boundary Explorer (IBEX) is determined based on IBEX-Lo Star Sensor observations. Accurate information on the boresight of the neutral gas camera is essential for precise determination of interstellar gas flow parameters. Utilizing spin-phase information from the spacecraft attitude control system (ACS), positions of stars observed by the Star Sensor during two years of IBEX measurements were analyzed and compared with positions obtained from a star catalog. No statistically significant differences were observed beyond those expected from the pre-launch uncertainty in the Star Sensor mounting. Based on the star observations and their positions in the spacecraft reference system, pointing of the IBEX satellite spin axis was determined and compared with the pointing obtained from the ACS. Again, no statistically significant deviations were observed. We conclude that no systematic correction for boresight geometry is needed in the analysis of IBEX-Lo observations to determine neutral interstellar gas flow properties. A stack-up of uncertainties in attitude knowledge shows that the instantaneous IBEX-Lo pointing is determined to within ∼0. 0 1 in both spin angle and elevation using either the Star Sensor or the ACS. Further, the Star Sensor can be used to independently determine the spacecraft spin axis. Thus, Star Sensor data can be used reliably to correct the spin phase when the Star Tracker (used by the ACS) is disabled by bright objects in its field of view. The Star Sensor can also determine the spin axis during most orbits and thus provides redundancy for the Star Tracker.

  8. Interacting dark sector and precision cosmology

    Science.gov (United States)

    Buen-Abad, Manuel A.; Schmaltz, Martin; Lesgourgues, Julien; Brinckmann, Thejs

    2018-01-01

    We consider a recently proposed model in which dark matter interacts with a thermal background of dark radiation. Dark radiation consists of relativistic degrees of freedom which allow larger values of the expansion rate of the universe today to be consistent with CMB data (H0-problem). Scattering between dark matter and radiation suppresses the matter power spectrum at small scales and can explain the apparent discrepancies between ΛCDM predictions of the matter power spectrum and direct measurements of Large Scale Structure LSS (σ8-problem). We go beyond previous work in two ways: 1. we enlarge the parameter space of our previous model and allow for an arbitrary fraction of the dark matter to be interacting and 2. we update the data sets used in our fits, most importantly we include LSS data with full k-dependence to explore the sensitivity of current data to the shape of the matter power spectrum. We find that LSS data prefer models with overall suppressed matter clustering due to dark matter - dark radiation interactions over ΛCDM at 3–4 σ. However recent weak lensing measurements of the power spectrum are not yet precise enough to clearly distinguish two limits of the model with different predicted shapes for the linear matter power spectrum. In two appendices we give a derivation of the coupled dark matter and dark radiation perturbation equations from the Boltzmann equation in order to clarify a confusion in the recent literature, and we derive analytic approximations to the solutions of the perturbation equations in the two physically interesting limits of all dark matter weakly interacting or a small fraction of dark matter strongly interacting.

  9. Precision Casting via Advanced Simulation and Manufacturing

    Science.gov (United States)

    1997-01-01

    A two-year program was conducted to develop and commercially implement selected casting manufacturing technologies to enable significant reductions in the costs of castings, increase the complexity and dimensional accuracy of castings, and reduce the development times for delivery of high quality castings. The industry-led R&D project was cost shared with NASA's Aerospace Industry Technology Program (AITP). The Rocketdyne Division of Boeing North American, Inc. served as the team lead with participation from Lockheed Martin, Ford Motor Company, Howmet Corporation, PCC Airfoils, General Electric, UES, Inc., University of Alabama, Auburn University, Robinson, Inc., Aracor, and NASA-LeRC. The technical effort was organized into four distinct tasks. The accomplishments reported herein. Task 1.0 developed advanced simulation technology for core molding. Ford headed up this task. On this program, a specialized core machine was designed and built. Task 2.0 focused on intelligent process control for precision core molding. Howmet led this effort. The primary focus of these experimental efforts was to characterize the process parameters that have a strong impact on dimensional control issues of injection molded cores during their fabrication. Task 3.0 developed and applied rapid prototyping to produce near net shape castings. Rocketdyne was responsible for this task. CAD files were generated using reverse engineering, rapid prototype patterns were fabricated using SLS and SLA, and castings produced and evaluated. Task 4.0 was aimed at developing technology transfer. Rocketdyne coordinated this task. Casting related technology, explored and evaluated in the first three tasks of this program, was implemented into manufacturing processes.

  10. Autonomous calibration of single spin qubit operations

    Science.gov (United States)

    Frank, Florian; Unden, Thomas; Zoller, Jonathan; Said, Ressa S.; Calarco, Tommaso; Montangero, Simone; Naydenov, Boris; Jelezko, Fedor

    2017-12-01

    Fully autonomous precise control of qubits is crucial for quantum information processing, quantum communication, and quantum sensing applications. It requires minimal human intervention on the ability to model, to predict, and to anticipate the quantum dynamics, as well as to precisely control and calibrate single qubit operations. Here, we demonstrate single qubit autonomous calibrations via closed-loop optimisations of electron spin quantum operations in diamond. The operations are examined by quantum state and process tomographic measurements at room temperature, and their performances against systematic errors are iteratively rectified by an optimal pulse engineering algorithm. We achieve an autonomous calibrated fidelity up to 1.00 on a time scale of minutes for a spin population inversion and up to 0.98 on a time scale of hours for a single qubit π/2 -rotation within the experimental error of 2%. These results manifest a full potential for versatile quantum technologies.

  11. High-precision laser microcutting and laser microdrilling using diffractive beam-splitting and high-precision flexible beam alignment

    Science.gov (United States)

    Zibner, F.; Fornaroli, C.; Holtkamp, J.; Shachaf, Lior; Kaplan, Natan; Gillner, A.

    2017-08-01

    High-precision laser micro machining gains more importance in industrial applications every month. Optical systems like the helical optics offer highest quality together with controllable and adjustable drilling geometry, thus as taper angle, aspect ratio and heat effected zone. The helical optics is based on a rotating Dove-prism which is mounted in a hollow shaft engine together with other optical elements like wedge prisms and plane plates. Although the achieved quality can be interpreted as extremely high the low process efficiency is a main reason that this manufacturing technology has only limited demand within the industrial market. The objective of the research studies presented in this paper is to dramatically increase process efficiency as well as process flexibility. During the last years, the average power of commercial ultra-short pulsed laser sources has increased significantly. The efficient utilization of the high average laser power in the field of material processing requires an effective distribution of the laser power onto the work piece. One approach to increase the efficiency is the application of beam splitting devices to enable parallel processing. Multi beam processing is used to parallelize the fabrication of periodic structures as most application only require a partial amount of the emitted ultra-short pulsed laser power. In order to achieve highest flexibility while using multi beam processing the single beams are diverted and re-guided in a way that enables the opportunity to process with each partial beam on locally apart probes or semimanufactures.

  12. Rapid and Precise Orbit Determination for the GOCE Satellite

    Science.gov (United States)

    Visser, P.; van den IJssel, J.; Van Helleputte, T.; Bock, H.; Jaeggi, A.; Beutler, G.; Heinze, M.

    2010-12-01

    The ESA GOCE Core Explorer Mission carries a 12-channel, dual-frequency Global Positioning System (GPS) receiver for high-accuracy precise orbit determination. Precise GOCE orbit solutions are used to accurately geolocate the observations taken by the primary science instrument, the gradiometer, that aims at collect- ing medium to short wavelength gravity information. In addition, the orbit solutions provide complementary in- formation for the long-wavelength gravity field part. Precise orbit determination is an integral part of the GOCE High-Level Processing Facility (HPF) that produces the best gravity field model products possible. A rapid (RSO) and precise science orbit (PSO) determination chain are providing orbit solutions with a precision of about 10 cm at 1 day latency and 2-3 cm at 4 weeks latency, respectively. The 4 weeks latency for the PSO product holds for the final validated version. An interim PSO product with comparable precision is provided with a latency of 1-2 weeks.

  13. Precisely timed signal transmission in neocortical networks with reliable intermediate-range projections

    Directory of Open Access Journals (Sweden)

    Martin P Nawrot

    2009-02-01

    Full Text Available The mammalian neocortex has a remarkable ability to precisely reproduce behavioral sequences or to reliably retrieve stored information. In contrast, spiking activity in behaving animals shows a considerable trial-to-trial variability and temporal irregularity. The signal propagation and processing underlying these conflicting observations is based on fundamental neurophysiological processes like synaptic transmission, signal integration within single cells, and spike formation. Each of these steps in the neuronal signaling chain has been studied separately to a great extend, but it has been difficult to judge how they interact and sum up in active sub-networks of neocortical cells. In the present study, we experimentally assessed the precision and reliability of small neocortical networks consisting of trans-columnar, intermediate-range projections (200 – 1000 µm on a millisecond time-scale. Employing photo-uncaging of glutamate in acute slices, we activated a number of distant pre-synaptic cells in a spatiotemporally precisely controlled manner, while monitoring the resulting membrane potential fluctuations of a post-synaptic cell. We found that signal integration in this part of the network is highly reliable and temporally precise. As numerical simulations showed, the residual membrane potential variability can be attributed to amplitude variability in synaptic transmission and may significantly contribute to trial-to-trial output variability of a rate signal. However, it does not impair the temporal accuracy of signal integration. We conclude that signals from intermediate-range projections onto neocortical neurons are propagated and integrated in a highly reliable and precise manner, and may serve as a substrate for temporally precise signal transmission in neocortical networks.

  14. A Precise Measurement of the Tau Lifetime

    CERN Document Server

    Abdallah, J; Adam, W; Adzic, P; Albrecht, T; Alderweireld, T; Alemany-Fernandez, R; Allmendinger, T; Allport, P P; Amaldi, Ugo; Amapane, N; Amato, S; Anashkin, E; Andreazza, A; Andringa, S; Anjos, N; Antilogus, P; Apel, W D; Arnoud, Y; Ask, S; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Ballestrero, A; Bambade, P; Barbier, R; Bardin, Dimitri Yuri; Barker, G J; Baroncelli, A; Battaglia, Marco; Baubillier, M; Becks, K H; Begalli, M; Behrmann, A; Ben-Haim, E; Benekos, N C; Benvenuti, Alberto C; Bérat, C; Berggren, M; Berntzon, L; Bertrand, D; Besançon, M; Besson, N; Bloch, D; Blom, M; Bluj, M; Bonesini, M; Boonekamp, M; Booth, P S L; Borisov, G; Botner, O; Bouquet, B; Bowcock, T J V; Boyko, I; Bracko, M; Brenner, R; Brodet, E; Brückman, P; Brunet, J M; Bugge, L; Buschmann, P; Calvi, M; Camporesi, T; Canale, V; Carena, F; Castro, N; Cavallo, F R; Chapkin, M M; Charpentier, P; Checchia, P; Chierici, R; Shlyapnikov, P; Chudoba, J; Chung, S U; Cieslik, K; Collins, P; Contri, R; Cosme, G; Cossutti, F; Costa, M J; Crennell, D J; Cuevas-Maestro, J; D'Hondt, J; Dalmau, J; Da Silva, T; Da Silva, W; Della Ricca, G; De Angelis, A; de Boer, Wim; De Clercq, C; De Lotto, B; De Maria, N; De Min, A; De Paula, L S; Di Ciaccio, L; Di Simone, A; Doroba, K; Drees, J; Dris, M; Eigen, G; Ekelöf, T J C; Ellert, M; Elsing, M; Espirito-Santo, M C; Fanourakis, G K; Fassouliotis, D; Feindt, M; Fernández, J; Ferrer, A; Ferro, F; Flagmeyer, U; Föth, H; Fokitis, E; Fulda-Quenzer, F; Fuster, J A; Gandelman, M; García, C; Gavillet, P; Gazis, E N; Gokieli, R; Golob, B; Gómez-Ceballos, G; Gonçalves, P; Graziani, E; Grosdidier, G; Grzelak, K; Guy, J; Haag, C; Hallgren, A; Hamacher, K; Hamilton, K; Haug, S; Hauler, F; Hedberg, V; Hennecke, M; Herr, H; Hoffman, J; Holmgren, S O; Holt, P J; Houlden, M A; Hultqvist, K; Jackson, J N; Jarlskog, G; Jarry, P; Jeans, D; Johansson, E K; Johansson, P D; Jonsson, P; Joram, C; Jungermann, L; Kapusta, F; Katsanevas, S; Katsoufis, E C; Kernel, G; Kersevan, B P; Kerzel, U; Kiiskinen, A P; King, B T; Kjaer, N J; Kluit, P; Kokkinias, P; Kourkoumelis, C; Kuznetsov, O; Krumshtein, Z; Kucharczyk, M; Lamsa, J; Leder, G; Ledroit, F; Leinonen, L; Leitner, R; Lemonne, J; Lepeltier, V; Lesiak, T; Liebig, W; Liko, D; Lipniacka, A; Lopes, J H; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J; Malek, A; Maltezos, S; Mandl, F; Marco, J; Marco, R; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Martínez-Rivero, C; Masik, J; Mastroyiannopoulos, N; Matorras, F; Matteuzzi, C; Mazzucato, F; Mazzucato, M; McNulty, R; Meroni, C; Migliore, E; Mitaroff, W A; Mjörnmark, U; Moa, T; Moch, M; Mönig, K; Monge, R; Montenegro, J; Moraes, D; Moreno, S; Morettini, P; Müller, U; Münich, K; Mulders, M; Mundim, L; Murray, W; Muryn, B; Myatt, G; Myklebust, T; Nassiakou, M; Navarria, Francesco Luigi; Nawrocki, K; Nicolaidou, R; Nikolenko, M; Oblakowska-Mucha, A; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, R; Österberg, K; Ouraou, A; Oyanguren, A; Paganoni, M; Paiano, S; Palacios, J P; Palka, H; Papadopoulou, T D; Pape, L; Parkes, C; Parodi, F; Parzefall, U; Passeri, A; Passon, O; Peralta, L; Perepelitsa, V F; Perrotta, A; Petrolini, A; Piedra, J; Pieri, L; Pierre, F; Pimenta, M; Piotto, E; Podobnik, T; Poireau, V; Pol, M E; Polok, G; Pozdnyakov, V; Pukhaeva, N; Pullia, A; Rames, J; Read, A; Rebecchi, P; Rehn, J; Reid, D; Reinhardt, R; Renton, P B; Richard, F; Rídky, J; Rivero, M; Rodríguez, D; Romero, A; Ronchese, P; Roudeau, P; Rovelli, T; Ruhlmann-Kleider, V; Ryabtchikov, D; Sadovskii, A; Salmi, L; Salt, J; Sander, C; Savoy-Navarro, A; Schwickerath, U; Segar, A; Sekulin, R L; Siebel, M; Sissakian, A N; Smadja, G; Smirnova, O G; Sokolov, A; Sopczak, A; Sosnowski, R; Spassoff, Tz; Stanitzki, M; Stocchi, A; Strauss, J; Stugu, B; Szczekowski, M; Szeptycka, M; Szumlak, T; Tabarelli de Fatis, T; Taffard, A C; Tegenfeldt, F; Timmermans, J; Tkatchev, L G; Tobin, M; Todorovova, S; Tomé, B; Tonazzo, A; Tortosa, P; Travnicek, P; Treille, D; Tristram, G; Trochimczuk, M; Troncon, C; Turluer, M L; Tyapkin, I A; Tyapkin, P; Tzamarias, S; Uvarov, V; Valenti, G; van Dam, P; Van Eldik, J; Van Lysebetten, A; Van Remortel, N; Van Vulpen, I; Vegni, G; Veloso, F; Venus, W A; Verdier, P; Verzi, V; Vilanova, D; Vitale, L; Vrba, V; Wahlen, H; Washbrook, A J; Weiser, C; Wicke, D; Wickens, J H; Wilkinson, G; Winter, M; Witek, M; Yushchenko, O P; Zalewska-Bak, A; Zalewski, P; Zavrtanik, D; Zhuravlov, V; Zimin, N I; Zintchenko, A; Zupan, M

    2004-01-01

    The tau lepton lifetime has been measured with the e+e- -> tau+tau- events collected by the DELPHI detector at LEP in the years 1991-1995. Three different methods have been exploited, using both one-prong and three-prong tau decay channels. Two measurements have been made using events in which both taus decay to a single charged particle. Combining these measurements gave tau_tau (1 prong) = 291.8 +/- 2.3 (stat) +/- 1.5 (sys) fs. A third measurement using taus which decayed to three charged particles yielded tau_tau (3 prong) = 288.6 +/- 2.4 (stat) +/- 1.3 (sys) fs. These were combined with previous DELPHI results to measure the tau lifetime, using the full LEP1 data sample, to be tau_tau = 290.9 +/- 1.4 (stat) +/- 1.0 (sys) fs.

  15. Autonomous execution of the Precision Immobilization Technique

    Science.gov (United States)

    Mascareñas, David D. L.; Stull, Christopher J.; Farrar, Charles R.

    2017-03-01

    Over the course of the last decade great advances have been made in autonomously driving cars. The technology has advanced to the point that driverless car technology is currently being tested on publicly accessed roadways. The introduction of these technologies onto publicly accessed roadways not only raises questions of safety, but also security. Autonomously driving cars are inherently cyber-physical systems and as such will have novel security vulnerabilities that couple both the cyber aspects of the vehicle including the on-board computing and any network data it makes use of, with the physical nature of the vehicle including its sensors, actuators, and the vehicle chassis. Widespread implementation of driverless car technology will require that both the cyber, as well as physical security concerns surrounding these vehicles are addressed. In this work, we specifically developed a control policy to autonomously execute the Precision Immobilization Technique, a.k.a. the PIT maneuver. The PIT maneuver was originally developed by law enforcement to end high-speed vehicular pursuits in a quasi-safe manner. However, there is still a risk of damage/roll-over to both the vehicle executing the PIT maneuver as well as to the vehicle subject to the PIT maneuver. In law enforcement applications, it would be preferable to execute the PIT maneuver using an autonomous vehicle, thus removing the danger to law-enforcement officers. Furthermore, it is entirely possible that unscrupulous individuals could inject code into an autonomously-driving car to use the PIT maneuver to immobilize other vehicles while maintaining anonymity. For these reasons it is useful to know how the PIT maneuver can be implemented on an autonomous car. In this work a simple control policy based on velocity pursuit was developed to autonomously execute the PIT maneuver using only a vision and range measurements that are both commonly collected by contemporary driverless cars. The ability of this

  16. Advanced navigation algorithms for precision landing

    Science.gov (United States)

    Zanetti, Renato

    2007-12-01

    A detailed analysis of autonomous navigation algorithms to achieve autonomous precision landing is presented. The problem of integrated attitude determination and inertial navigation is solved. The theoretical results are applied and tested in three different applications. Optimality conditions for constrained quaternion estimation using the Kalman filter are derived. It is common in spacecraft applications to separate the attitude determination from the inertial navigation system. While this approach has worked in the past, it inevitably degrades the navigation performance when the correlations between the two systems are not correctly accounted for. It is shown how to optimally include an attitude determination algorithm into the Kalman filter. When the conditions to achieve optimality are not met, it is shown how to achieve sub-optimality by properly accounting for the correlation. The traditional approach to inertial navigation is to employ the inertial measurement unit (IMU) outputs to propagate the estimated states forward in time, rather then use them to update the state. This approach, known as dead-reckoning, allows for a simplified dynamics model, which in turn reduces the process noise, a contributor to the estimation error. A detailed covariance analysis of dead-reckoning Mars entry navigation is performed. The contribution of various sources of IMU errors are explicitly accounted for and the filter performance is validated through Monte Carlo analysis. The drawback of dead-reckoning is that this approach prevents the inertial measurements from reducing the uncertainty of the estimated states. While this shortcoming can be compensated by the availability of other measurements, it becomes crucial when the IMU is the only sensor to provide measurements. Such a situation arises, for example, during Mars atmospheric entry. In the second application of this work, IMU measurements from a NASA mission are processed in an extended Kalman filter, and the results

  17. Precision Agriculture: Changing the Face of Farming

    Science.gov (United States)

    Rickman, D.; Luvall, J.; Mask, P.; Shaw, J.; Kissel, D.; Sullivan, D.

    2003-01-01

    . Just a one percent increase in efficiency is a $2,000,000 change. We all depend on farmers, literally for the bread we eat. No other activity of man even has an impact on the land that farming has. If application of precision agriculture can nelp farmers manage their land better, we all may benefit.

  18. Modeling and Positioning of a PZT Precision Drive System

    OpenAIRE

    Liu, Che; Guo, Yanling

    2017-01-01

    The fact that piezoelectric ceramic transducer (PZT) precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circu...

  19. Evaluating impacts of unexpected earning on precision of profit estimation

    OpenAIRE

    Hossein Kazemi; Atefeh Khoshnodi

    2013-01-01

    Precision in earning report has always been a concern among investors, and when there are some negative adjustments on earning, investor may find it challenging to decide whether they should hold or sell their shares. This paper studies the impact of earning precision and unexpected earning adjustments on firms whose share are listed on Tehran Stock Exchange. The proposed study of this paper considers three hypotheses including whether earning precision has negative relationship with unexpect...

  20. How is precision regulated in maintaining trunk posture?

    OpenAIRE

    Willigenburg, Nienke W.; Kingma, Idsart; van Die?n, Jaap H.

    2010-01-01

    Precision of limb control is associated with increased joint stiffness caused by antagonistic co-activation. The aim of this study was to examine whether this strategy also applies to precision of trunk postural control. To this end, thirteen subjects performed static postural tasks, aiming at a target object with a cursor that responded to 2D trunk angles. By manipulating target dimensions, different levels of precision were imposed in the frontal and sagittal planes. Trunk angle and electro...

  1. precision deburring using NC and robot equipment. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, L.K.

    1980-05-01

    Deburring precision miniature components is often time consuming and inconsistent. Although robots are available for deburring parts, they are not precise enough for precision miniature parts. Numerical control (NC) machining can provide edge break consistencies to meet requirements such as 76.2-..mu..m maximum edge break (chamfer). Although NC machining has a number of technical limitations which prohibits its use on many geometries, it can be an effective approach to features that are particularly difficult to deburr.

  2. Using Precision in STEM Language: A Qualitative Look

    OpenAIRE

    Capraro, Mary Margaret; Bicer, Ali; Grant, Melva R.; Lincoln, Yvonna S.

    2017-01-01

    Teachers need to develop a variety of pedagogical strategies that can encourage precise and accurate communication - an extremely important 21st century skill. Precision with STEM oral language is essential. Emphasizing oral communication with precise language in combination with increased spatial skills with modeling can improve the chances of success in STEM courses and later in making STEM career choices. The participants were 14 middle and high school teachers who participated in a week o...

  3. Invariance for Single Curved Manifold

    KAUST Repository

    Castro, Pedro Machado Manhaes de

    2012-08-01

    Recently, it has been shown that, for Lambert illumination model, solely scenes composed by developable objects with a very particular albedo distribution produce an (2D) image with isolines that are (almost) invariant to light direction change. In this work, we provide and investigate a more general framework, and we show that, in general, the requirement for such in variances is quite strong, and is related to the differential geometry of the objects. More precisely, it is proved that single curved manifolds, i.e., manifolds such that at each point there is at most one principal curvature direction, produce invariant is surfaces for a certain relevant family of energy functions. In the three-dimensional case, the associated energy function corresponds to the classical Lambert illumination model with albedo. This result is also extended for finite-dimensional scenes composed by single curved objects. © 2012 IEEE.

  4. Precision Seismic Monitoring of Volcanic Eruptions at Axial Seamount

    Science.gov (United States)

    Waldhauser, F.; Wilcock, W. S. D.; Tolstoy, M.; Baillard, C.; Tan, Y. J.; Schaff, D. P.

    2017-12-01

    Seven permanent ocean bottom seismometers of the Ocean Observatories Initiative's real time cabled observatory at Axial Seamount off the coast of the western United States record seismic activity since 2014. The array captured the April 2015 eruption, shedding light on the detailed structure and dynamics of the volcano and the Juan de Fuca midocean ridge system (Wilcock et al., 2016). After a period of continuously increasing seismic activity primarily associated with the reactivation of caldera ring faults, and the subsequent seismic crisis on April 24, 2015 with 7000 recorded events that day, seismicity rates steadily declined and the array currently records an average of 5 events per day. Here we present results from ongoing efforts to automatically detect and precisely locate seismic events at Axial in real-time, providing the computational framework and fundamental data that will allow rapid characterization and analysis of spatio-temporal changes in seismogenic properties. We combine a kurtosis-based P- and S-phase onset picker and time domain cross-correlation detection and phase delay timing algorithms together with single-event and double-difference location methods to rapidly and precisely (tens of meters) compute the location and magnitudes of new events with respect to a 2-year long, high-resolution background catalog that includes nearly 100,000 events within a 5×5 km region. We extend the real-time double-difference location software DD-RT to efficiently handle the anticipated high-rate and high-density earthquake activity during future eruptions. The modular monitoring framework will allow real-time tracking of other seismic events such as tremors and sea-floor lava explosions that enable the timing and location of lava flows and thus guide response research cruises to the most interesting sites. Finally, rapid detection of eruption precursors and initiation will allow for adaptive sampling by the OOI instruments for optimal recording of future

  5. Precision and linearity targets for validation of an IFNγ ELISPOT, cytokine flow cytometry, and tetramer assay using CMV peptides

    Directory of Open Access Journals (Sweden)

    Lyerly Herbert K

    2008-03-01

    Full Text Available Abstract Background Single-cell assays of immune function are increasingly used to monitor T cell responses in immunotherapy clinical trials. Standardization and validation of such assays are therefore important to interpretation of the clinical trial data. Here we assess the levels of intra-assay, inter-assay, and inter-operator precision, as well as linearity, of CD8+ T cell IFNγ-based ELISPOT and cytokine flow cytometry (CFC, as well as tetramer assays. Results Precision was measured in cryopreserved PBMC with a low, medium, or high response level to a CMV pp65 peptide or peptide mixture. Intra-assay precision was assessed using 6 replicates per assay; inter-assay precision was assessed by performing 8 assays on different days; and inter-operator precision was assessed using 3 different operators working on the same day. Percent CV values ranged from 4% to 133% depending upon the assay and response level. Linearity was measured by diluting PBMC from a high responder into PBMC from a non-responder, and yielded R2 values from 0.85 to 0.99 depending upon the assay and antigen. Conclusion These data provide target values for precision and linearity of single-cell assays for those wishing to validate these assays in their own laboratories. They also allow for comparison of the precision and linearity of ELISPOT, CFC, and tetramer across a range of response levels. There was a trend toward tetramer assays showing the highest precision, followed closely by CFC, and then ELISPOT; while all three assays had similar linearity. These findings are contingent upon the use of optimized protocols for each assay.

  6. High precision measurements of the luminosity at LEP

    International Nuclear Information System (INIS)

    Pietrzyk, B.

    1994-01-01

    The art of the luminosity measurements at LEP is presented. First generation LEP detectors have measured the absolute luminosity with the precision of 0.3-0.5%. The most precise present detectors have reached the 0.07% precision and the 0.05% is not excluded in future. Center-of-mass energy dependent relative precision of the luminosity detectors and the use of the theoretical cross-section in the LEP experiments are also discussed. (author). 18 refs., 6 figs., 6 tabs

  7. Sampling plans in attribute mode with multiple levels of precision

    International Nuclear Information System (INIS)

    Franklin, M.

    1986-01-01

    This paper describes a method for deriving sampling plans for nuclear material inventory verification. The method presented is different from the classical approach which envisages two levels of measurement precision corresponding to NDA and DA. In the classical approach the precisions of the two measurement methods are taken as fixed parameters. The new approach is based on multiple levels of measurement precision. The design of the sampling plan consists of choosing the number of measurement levels, the measurement precision to be used at each level and the sample size to be used at each level

  8. High precision target center determination from a point cloud

    Directory of Open Access Journals (Sweden)

    K. Kregar

    2013-10-01

    Full Text Available Many applications of terrestrial laser scanners (TLS require the determination of a specific point from a point cloud. In this paper procedure of high precision planar target center acquisition from point cloud is presented. The process is based on an image matching algorithm but before we can deal with raster image to fit a target on it, we need to properly determine the best fitting plane and project points on it. The main emphasis of this paper is in the precision estimation and propagation through the whole procedure which allows us to obtain precision assessment of final results (target center coordinates. Theoretic precision estimations – obtained through the procedure were rather high so we compared them with the empiric precision estimations obtained as standard deviations of results of 60 independently scanned targets. An χ2-test confirmed that theoretic precisions are overestimated. The problem most probably lies in the overestimated precisions of the plane parameters due to vast redundancy of points. However, empirical precisions also confirmed that the proposed procedure can ensure a submillimeter precision level. The algorithm can automatically detect grossly erroneous results to some extent. It can operate when the incidence angles of a laser beam are as high as 80°, which is desirable property if one is going to use planar targets as tie points in scan registration. The proposed algorithm will also contribute to improve TLS calibration procedures.

  9. Advanced precision expendable pattern casting technology. 1994 Summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    Casting technology is described. The following areas are reported on: precision pattern production; pattern coating; sand fill and compaction; pattern gating; mechanical properties; and technology transfer efforts.

  10. Introduction to precision machine design and error assessment

    CERN Document Server

    Mekid, Samir

    2008-01-01

    While ultra-precision machines are now achieving sub-nanometer accuracy, unique challenges continue to arise due to their tight specifications. Written to meet the growing needs of mechanical engineers and other professionals to understand these specialized design process issues, Introduction to Precision Machine Design and Error Assessment places a particular focus on the errors associated with precision design, machine diagnostics, error modeling, and error compensation. Error Assessment and ControlThe book begins with a brief overview of precision engineering and applications before introdu

  11. Pressure Controlled Heat Pipe for Precise Temperature Control, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research project will develop Pressure Controlled Heat Pipes (PCHPs) for precise temperature control (milli-Kelvin level). Several...

  12. MITP Workshop on Low-Energy Precision Physics

    CERN Document Server

    2013-01-01

    The scientific program will be focussed on the theory of low-energy precision physics relevant to the MESA and TRIGA initiatives. Topics include searches for TeV-scale physics beyond the Standard Model via ultra-precise measurements of parity-violating electron scattering asymmetries, determinations of neutron decay parameters via precision measurements of its lifetime and decay asymmetries, and searches for EDMs of nucleons, nuclei and atoms. The necessary high-precision theoretical tools to analyse these experiments, which include advanced calculations of radiative corrections, will be explored and developed.

  13. Attaining the Photometric Precision Required by Future Dark Energy Projects

    Energy Technology Data Exchange (ETDEWEB)

    Stubbs, Christopher [Harvard Univ., Cambridge, MA (United States)

    2013-01-21

    This report outlines our progress towards achieving the high-precision astronomical measurements needed to derive improved constraints on the nature of the Dark Energy. Our approach to obtaining higher precision flux measurements has two basic components: 1) determination of the optical transmission of the atmosphere, and 2) mapping out the instrumental photon sensitivity function vs. wavelength, calibrated by referencing the measurements to the known sensitivity curve of a high precision silicon photodiode, and 3) using the self-consistency of the spectrum of stars to achieve precise color calibrations.

  14. SpecBit, DecayBit and PrecisionBit: GAMBIT modules for computing mass spectra, particle decay rates and precision observables

    Science.gov (United States)

    Athron, Peter; Balázs, Csaba; Dal, Lars A.; Edsjö, Joakim; Farmer, Ben; Gonzalo, Tomás E.; Kvellestad, Anders; McKay, James; Putze, Antje; Rogan, Chris; Scott, Pat; Weniger, Christoph; White, Martin

    2018-01-01

    We present the GAMBIT modules SpecBit, DecayBit and PrecisionBit. Together they provide a new framework for linking publicly available spectrum generators, decay codes and other precision observable calculations in a physically and statistically consistent manner. This allows users to automatically run various combinations of existing codes as if they are a single package. The modular design allows software packages fulfilling the same role to be exchanged freely at runtime, with the results presented in a common format that can easily be passed to downstream dark matter, collider and flavour codes. These modules constitute an essential part of the broader GAMBIT framework, a major new software package for performing global fits. In this paper we present the observable calculations, data, and likelihood functions implemented in the three modules, as well as the conventions and assumptions used in interfacing them with external codes. We also present 3-BIT-HIT, a command-line utility for computing mass spectra, couplings, decays and precision observables in the MSSM, which shows how the three modules can easily be used independently of GAMBIT.

  15. Lack of precision of burn surface area calculation by UK Armed Forces medical personnel.

    Science.gov (United States)

    Martin, Niall A J; Lundy, Jonathan B; Rickard, Rory F

    2014-03-01

    Accurate determination of the severity of burn is essential for the care of thermally injured patients. We aimed to examine the accuracy and precision of TBSA calculation performed by specialist military burn care providers and non-specialist but experienced military clinicians. Using a single case example with photographic montages and a modified Lund and Browder chart, the two cohorts of clinicians were each given 10min to map and calculate the case example TBSA involvement. The accuracy and precision of results from the two cohorts were compared to a set standard %TBSA. The set standard %TBSA involvement was 64.5%. Mean %TBSA mapped by non-specialists (52.53±10.03%) differed significantly from the set standard (pburn care providers (65.68±10.29%; p=0.622). However, when comparing precision of calculation of TBSA burned, there was no evidence of a difference in heterogeneity of results between the two cohorts (F test, p=0.639; Levene's test, p=0.448). These results indicate that experienced military burn care providers overall more accurately assess %TBSA burned than relatively inexperienced clinicians. However, results demonstrate a lack of precision in both groups. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  16. Segment-embedded frame definition affects the hip joint centre precision during walking.

    Science.gov (United States)

    Roosen, Andy; Pain, Matthew T G; Thouzé, Arsène; Monnet, Tony; Begon, Mickaël

    2013-08-01

    Due to marker-specific soft tissue artefacts, the choice of the markers defining the segment-embedded frame affects the functional joint centre location, with subsequent error propagation to joint kinematics and kinetics in gait analysis. Our aim was to assess the effect of the number and placement of markers on the precision of the hip joint centre (HJC) location during walking. Twelve markers (2x6) were attached to the pelvis and left thigh of 15 young male subjects. Set-up movements were collected to locate an optimised functional HJC. For all permutations of three from six markers, a HJC was located and subsequently reconstructed in a static trial and during walking. Precision measures with two different definitions of the origin, namely a single maker or their mean-point, and using three, four, five and six were calculated. Finally, marker triads that reduced the variability of the HJC location were determined. Both the number of markers and method for defining the origin significantly affected the HJC precision during static and walking trials. For walking, precision of 39 mm using three markers improved to 5mm using redundant markers and the mean marker position as the segment origin. Markers placed close to the joint gave more consistent results. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  17. Real-Time IGS products verification in the context of their use in Precise Point Positioning

    Science.gov (United States)

    Hadas, Tomasz; Bosy, Jaroslaw; Kaplon, Jan; Sierny, Jan

    2013-04-01

    Precise Point Positioning (PPP) is a positioning technique of single GNSS receiver which applies high quality products from permanent GNSS observations to utilize the computational potential of global network analysis. Estimated satellite orbits and clocks corrections are introduced into equation system as known parameters. PPP requires the application of precise products, since their quality directly reflects the positioning accuracy. In June 2007 IGS Real-time Pilot Project has started in order to satisfy real-time users, which is especially important for Precise Point Positioning. Currently available streams including precise orbits, clocks and code biases are standardized on RTCM-SC 104 formats and may be used as a substitute for ultra-rapid products. The target combination product performances are 0.3ns for satellite clock accuracy and orbit accuracy at the level of the IGS Ultra predictions with maximum latency of 10s. This study presents the quality assessment of currently available Real-Time IGS products. Long-term test include comparisons of disseminated information with final and high-rate products, stability assessment over time, as well as latency validation of available RTCM streams.

  18. The effects of selective and divided attention on sensory precision and integration.

    Science.gov (United States)

    Odegaard, Brian; Wozny, David R; Shams, Ladan

    2016-02-12

    In our daily lives, our capacity to selectively attend to stimuli within or across sensory modalities enables enhanced perception of the surrounding world. While previous research on selective attention has studied this phenomenon extensively, two important questions still remain unanswered: (1) how selective attention to a single modality impacts sensory integration processes, and (2) the mechanism by which selective attention improves perception. We explored how selective attention impacts performance in both a spatial task and a temporal numerosity judgment task, and employed a Bayesian Causal Inference model to investigate the computational mechanism(s) impacted by selective attention. We report three findings: (1) in the spatial domain, selective attention improves precision of the visual sensory representations (which were relatively precise), but not the auditory sensory representations (which were fairly noisy); (2) in the temporal domain, selective attention improves the sensory precision in both modalities (both of which were fairly reliable to begin with); (3) in both tasks, selective attention did not exert a significant influence over the tendency to integrate sensory stimuli. Therefore, it may be postulated that a sensory modality must possess a certain inherent degree of encoding precision in order to benefit from selective attention. It also appears that in certain basic perceptual tasks, the tendency to integrate crossmodal signals does not depend significantly on selective attention. We conclude with a discussion of how these results relate to recent theoretical considerations of selective attention. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  19. Direct high-precision measurement of the magnetic moment of the proton.

    Science.gov (United States)

    Mooser, A; Ulmer, S; Blaum, K; Franke, K; Kracke, H; Leiteritz, C; Quint, W; Rodegheri, C C; Smorra, C; Walz, J

    2014-05-29

    One of the fundamental properties of the proton is its magnetic moment, µp. So far µp has been measured only indirectly, by analysing the spectrum of an atomic hydrogen maser in a magnetic field. Here we report the direct high-precision measurement of the magnetic moment of a single proton using the double Penning-trap technique. We drive proton-spin quantum jumps by a magnetic radio-frequency field in a Penning trap with a homogeneous magnetic field. The induced spin transitions are detected in a second trap with a strong superimposed magnetic inhomogeneity. This enables the measurement of the spin-flip probability as a function of the drive frequency. In each measurement the proton's cyclotron frequency is used to determine the magnetic field of the trap. From the normalized resonance curve, we extract the particle's magnetic moment in terms of the nuclear magneton: μp = 2.792847350(9)μN. This measurement outperforms previous Penning-trap measurements in terms of precision by a factor of about 760. It improves the precision of the forty-year-old indirect measurement, in which significant theoretical bound state corrections were required to obtain µp, by a factor of 3. By application of this method to the antiproton magnetic moment, the fractional precision of the recently reported value can be improved by a factor of at least 1,000. Combined with the present result, this will provide a stringent test of matter/antimatter symmetry with baryons.

  20. Local high precision 3D measurement based on line laser measuring instrument

    Science.gov (United States)

    Zhang, Renwei; Liu, Wei; Lu, Yongkang; Zhang, Yang; Ma, Jianwei; Jia, Zhenyuan

    2018-03-01

    In order to realize the precision machining and assembly of the parts, the geometrical dimensions of the surface of the local assembly surfaces need to be strictly guaranteed. In this paper, a local high-precision three-dimensional measurement method based on line laser measuring instrument is proposed to achieve a high degree of accuracy of the three-dimensional reconstruction of the surface. Aiming at the problem of two-dimensional line laser measuring instrument which lacks one-dimensional high-precision information, a local three-dimensional profile measuring system based on an accurate single-axis controller is proposed. First of all, a three-dimensional data compensation method based on spatial multi-angle line laser measuring instrument is proposed to achieve the high-precision measurement of the default axis. Through the pretreatment of the 3D point cloud information, the measurement points can be restored accurately. Finally, the target spherical surface is needed to make local three-dimensional scanning measurements for accuracy verification. The experimental results show that this scheme can get the local three-dimensional information of the target quickly and accurately, and achieves the purpose of gaining the information and compensating the error for laser scanner information, and improves the local measurement accuracy.

  1. Precise Plan in the analysis of volume precision in SynergyTM conebeam CT image

    International Nuclear Information System (INIS)

    Bai Sen; Xu Qingfeng; Zhong Renming; Jiang Xiaoqin; Jiang Qingfeng; Xu Feng

    2007-01-01

    Objective: A method of checking the volume precision in Synergy TM conebeam CT image. Methods: To scan known phantoms (big, middle, small spheres, cubes and cuniform cavum) at different positions (CBCT centre and departure centre from 5, 8, 10 cm along the accelerator G-T way)with conebeam CT, the phantom volume of reconstructed images were measure. Then to compared measured volume of Synergy TM conebeam CT with fanbeam CT results and nominal values. Results: The middle spheres had 1.5% discrepancy in nominal values and metrical average values at CBCT centre and departure from centre 5, 8 cm along accelerator G-T way. The small spheres showed 8.1%, with 0.8 % of the big cube and 2.9% of small cube, in nominal values and metrical average values at CBCT centre and departure from centre 5, 8, 10 cm along the accelerator G-T way. Conclusion: In valid scan range of Synergy TM conebeam CT, reconstructed precision is independent of the distance deviation from the center. (authors)

  2. Data Collection Satellite Application in Precision Agriculture

    Science.gov (United States)

    Durào, O.

    2002-01-01

    's over Brazilian territory. There were 25 platforms when SCD-1 was launched. However this number is growing rapidly to 400 platforms, at first for measurements of water reservoir levels as well as other hydrology applications (The Brazilian Electricity Regulatory Agency - ANEEL is the customer), and for many other different applications such as meteorology, oceanography, environmental monitoring sciences, and people and animal tracking. The clear feeling is that users are discovering a satellite system whose benefits were not previously well understood when launched and being able to propose and come up with different and useful applications. A new field in the country that has a great potential to benefit from this system is agriculture. Per se, this is a very important sector of the Brazilian economy and its international trade. Combining it with space technology may justify the investment of new and low cost dedicated satellites. This paper describes a new proposal for use of the SCD-1,2,CBERS-1 satellite system for precision agriculture. New PCD's would be developed for measurements of chemical content of the soil, such as, for example, Nitrogen and others, beyond humidity and solar incidence. This can lead to a more efficient fertilization, harvesting and even the spray of chemical defensives, with the consequence of environment protection. The PCD's ground network so established, along with the information network already available, combined with the space segment of such a system may, as previously said, be able to justify the investment in low cost satellites with this sole purpose.

  3. Sub-micrometer-precision, three-dimensional (3D) hydrodynamic focusing via “microfluidic drifting”

    Science.gov (United States)

    Nawaz, Ahmad Ahsan; Zhang, Xiangjun; Mao, Xiaole; Rufo, Joseph; Lin, Sz-Chin Steven; Guo, Feng; Zhao, Yanhui; Lapsley, Michael; Li, Peng; McCoy, J. Philip; Levine, Stewart J.; Huang, Tony Jun

    2014-01-01

    In this article, we demonstrate single-layered, “microfluidic drifting” based three-dimensional (3D) hydrodynamic focusing devices with particle/cell focal positioning approaching submicron precision along both lateral and vertical directions. By systematically optimizing channel geometries and sample/sheath flow rates, a series of “microfluidic drifting” based 3D hydrodynamic focusing devices with different curvature angles are designed and fabricated. Their performances are then evaluated by confocal microscopy, fast camera imaging, and side-view imaging techniques. Using a device with a curvature angle of 180°, we have achieved a standard deviation of ±0.45 µm in particle focal position and a coefficient of variation (CV) of 2.37% in flow cytometric measurements. To the best of our knowledge, this is the best CV that has been achieved by a microfluidic flow cytometry device. Moreover, the device showed the capability to distinguish 8 peaks when subjected to a stringent 8-peak rainbow calibration test, signifying the ability to perform sensitive, accurate tests similar to commercial flow cytometers. We have further tested and validated our device by detection of HEK-293 cells. With its advantages in simple fabrication (i.e., single-layered device), precise 3D hydrodynamic focusing (i.e., submicrometer precision along both lateral and vertical directions), and high detection resolution (i.e., low CV), our method could serve as an important basis for high-performance, mass-producible microfluidic flow cytometry. PMID:24287742

  4. Sub-micrometer-precision, three-dimensional (3D) hydrodynamic focusing via "microfluidic drifting".

    Science.gov (United States)

    Nawaz, Ahmad Ahsan; Zhang, Xiangjun; Mao, Xiaole; Rufo, Joseph; Lin, Sz-Chin Steven; Guo, Feng; Zhao, Yanhui; Lapsley, Michael; Li, Peng; McCoy, J Philip; Levine, Stewart J; Huang, Tony Jun

    2014-01-21

    In this article, we demonstrate single-layered, "microfluidic drifting" based three-dimensional (3D) hydrodynamic focusing devices with particle/cell focal positioning approaching submicron precision along both lateral and vertical directions. By systematically optimizing channel geometries and sample/sheath flow rates, a series of "microfluidic drifting" based 3D hydrodynamic focusing devices with different curvature angles are designed and fabricated. Their performances are then evaluated using confocal microscopy, fast camera imaging, and side-view imaging techniques. Using a device with a curvature angle of 180°, we have achieved a standard deviation of ±0.45 μm in particle focal position and a coefficient of variation (CV) of 2.37% in flow cytometric measurements. To the best of our knowledge, this is the best CV that has been achieved using a microfluidic flow cytometry device. Moreover, the device showed the capability to distinguish 8 peaks when subjected to a stringent 8-peak rainbow calibration test, signifying the ability to perform sensitive, accurate tests similar to commercial flow cytometers. We have further tested and validated our device by detection of HEK-293 cells. With its advantages in simple fabrication (i.e., single-layered device), precise 3D hydrodynamic focusing (i.e., submicrometer precision along both lateral and vertical directions), and high detection resolution (i.e., low CV), our method could serve as an important basis for high-performance, mass-producible microfluidic flow cytometry.

  5. Fabrication of ultrahigh-precision hemispherical mirrors for quantum-optics applications.

    Science.gov (United States)

    Higginbottom, Daniel B; Campbell, Geoff T; Araneda, Gabriel; Fang, Fengzhou; Colombe, Yves; Buchler, Ben C; Lam, Ping Koy

    2018-01-09

    High precision, high numerical aperture mirrors are desirable for mediating strong atom-light coupling in quantum optics applications and can also serve as important reference surfaces for optical metrology. In this work we demonstrate the fabrication of highly-precise hemispheric mirrors with numerical aperture NA = 0.996. The mirrors were fabricated from aluminum by single-point diamond turning using a stable ultra-precision lathe calibrated with an in-situ white-light interferometer. Our mirrors have a diameter of 25 mm and were characterized using a combination of wide-angle single-shot and small-angle stitched multi-shot interferometry. The measurements show root-mean-square (RMS) form errors consistently below 25 nm. The smoothest of our mirrors has a RMS error of 14 nm and a peak-to-valley (PV) error of 88 nm, which corresponds to a form accuracy of λ/50 for visible optics.

  6. Precision Health Economics and Outcomes Research to Support Precision Medicine: Big Data Meets Patient Heterogeneity on the Road to Value

    Science.gov (United States)

    Chen, Yixi; Guzauskas, Gregory F.; Gu, Chengming; Wang, Bruce C. M.; Furnback, Wesley E.; Xie, Guotong; Dong, Peng; Garrison, Louis P.

    2016-01-01

    The “big data” era represents an exciting opportunity to utilize powerful new sources of information to reduce clinical and health economic uncertainty on an individual patient level. In turn, health economic outcomes research (HEOR) practices will need to evolve to accommodate individual patient–level HEOR analyses. We propose the concept of “precision HEOR”, which utilizes a combination of costs and outcomes derived from big data to inform healthcare decision-making that is tailored to highly specific patient clusters or individuals. To explore this concept, we discuss the current and future roles of HEOR in health sector decision-making, big data and predictive analytics, and several key HEOR contexts in which big data and predictive analytics might transform traditional HEOR into precision HEOR. The guidance document addresses issues related to the transition from traditional to precision HEOR practices, the evaluation of patient similarity analysis and its appropriateness for precision HEOR analysis, and future challenges to precision HEOR adoption. Precision HEOR should make precision medicine more realizable by aiding and adapting healthcare resource allocation. The combined hopes for precision medicine and precision HEOR are that individual patients receive the best possible medical care while overall healthcare costs remain manageable or become more cost-efficient. PMID:27827859

  7. Precision Health Economics and Outcomes Research to Support Precision Medicine: Big Data Meets Patient Heterogeneity on the Road to Value

    Directory of Open Access Journals (Sweden)

    Yixi Chen

    2016-11-01

    Full Text Available The “big data” era represents an exciting opportunity to utilize powerful new sources of information to reduce clinical and health economic uncertainty on an individual patient level. In turn, health economic outcomes research (HEOR practices will need to evolve to accommodate individual patient–level HEOR analyses. We propose the concept of “precision HEOR”, which utilizes a combination of costs and outcomes derived from big data to inform healthcare decision-making that is tailored to highly specific patient clusters or individuals. To explore this concept, we discuss the current and future roles of HEOR in health sector decision-making, big data and predictive analytics, and several key HEOR contexts in which big data and predictive analytics might transform traditional HEOR into precision HEOR. The guidance document addresses issues related to the transition from traditional to precision HEOR practices, the evaluation of patient similarity analysis and its appropriateness for precision HEOR analysis, and future challenges to precision HEOR adoption. Precision HEOR should make precision medicine more realizable by aiding and adapting healthcare resource allocation. The combined hopes for precision medicine and precision HEOR are that individual patients receive the best possible medical care while overall healthcare costs remain manageable or become more cost-efficient.

  8. Applications of Seafloor Mapping Using Precise Sonars

    Directory of Open Access Journals (Sweden)

    Jerneja Fridl

    2009-05-01

    Full Text Available Seafloor measurements using single-beam, multi-beam, sub-bottom, and side-scan sonars which enable detailed mapping of solid objects in sediments, seafloor structure and depth can provide useful information for marine traffic as well as scientific studies. The measurements obtained using these technologies, which provide a large number of points, make possible the preparation of an accurate digital bathymetric model. The most widely used application of these kinds of measurements is undoubtedly to determine depths of marinas, berths and shipping channels, especially around large commercial ports. However, their importance in the discovery and investigation of undersea archaeological sites such as shipwrecks, ancient piers, and amphorae is not to be ignored. The data are also useful for geologists, since they can provide clues as to the type of seafloor and the composition of rocks underneath the sediments. They can also be helpful to nature conservationists in locating and studying undersea springs and grassy areas of the seafloor which provide habitat for marine fauna. In order to facilitate access to data by users, we are developing an “undersea information system” containing different layers of data in various forms and with different types of content. Findings from the latest research can be added to the system. A system set up in this way would allow for faster production of three-dimensional seafloor models, more detailed charts and a variety of thematic maps.

  9. BS Seeker: precise mapping for bisulfite sequencing

    Directory of Open Access Journals (Sweden)

    Pellegrini Matteo

    2010-04-01

    Full Text Available Abstract Background Bisulfite sequencing using next generation sequencers yields genome-wide measurements of DNA methylation at single nucleotide resolution. Traditional aligners are not designed for mapping bisulfite-treated reads, where the unmethylated Cs are converted to Ts. We have developed BS Seeker, an approach that converts the genome to a three-letter alphabet and uses Bowtie to align bisulfite-treated reads to a reference genome. It uses sequence tags to reduce mapping ambiguity. Post-processing of the alignments removes non-unique and low-quality mappings. Results We tested our aligner on synthetic data, a bisulfite-converted Arabidopsis library, and human libraries generated from two different experimental protocols. We evaluated the performance of our approach and compared it to other bisulfite aligners. The results demonstrate that among the aligners tested, BS Seeker is more versatile and faster. When mapping to the human genome, BS Seeker generates alignments significantly faster than RMAP and BSMAP. Furthermore, BS Seeker is the only alignment tool that can explicitly account for tags which are generated by certain library construction protocols. Conclusions BS Seeker provides fast and accurate mapping of bisulfite-converted reads. It can work with BS reads generated from the two different experimental protocols, and is able to efficiently map reads to large mammalian genomes. The Python program is freely available at http://pellegrini.mcdb.ucla.edu/BS_Seeker/BS_Seeker.html.

  10. PRECISE HEAD TRACKING IN HEARING APPLICATIONS

    Directory of Open Access Journals (Sweden)

    A. M. Helle

    2015-05-01

    Full Text Available The paper gives an overview about two research projects, both dealing with optical head tracking in hearing applications. As part of the project “Development of a real-time low-cost tracking system for medical and audiological problems (ELCoT” a cost-effective single camera 3D tracking system has been developed which enables the detection of arm and head movements of human patients. Amongst others, the measuring system is designed for a new hearing test (based on the “Mainzer Kindertisch”, which analyzes the directional hearing capabilities of children in cooperation with the research project ERKI (Evaluation of acoustic sound source localization for children. As part of the research project framework “Hearing in everyday life (HALLO” a stereo tracking system is being used for analyzing the head movement of human patients during complex acoustic events. Together with the consideration of biosignals like skin conductance the speech comprehension and listening effort of persons with reduced hearing ability, especially in situations with background noise, is evaluated. For both projects the system design, accuracy aspects and results of practical tests are discussed.

  11. Precise Head Tracking in Hearing Applications

    Science.gov (United States)

    Helle, A. M.; Pilinski, J.; Luhmann, T.

    2015-05-01

    The paper gives an overview about two research projects, both dealing with optical head tracking in hearing applications. As part of the project "Development of a real-time low-cost tracking system for medical and audiological problems (ELCoT)" a cost-effective single camera 3D tracking system has been developed which enables the detection of arm and head movements of human patients. Amongst others, the measuring system is designed for a new hearing test (based on the "Mainzer Kindertisch"), which analyzes the directional hearing capabilities of children in cooperation with the research project ERKI (Evaluation of acoustic sound source localization for children). As part of the research project framework "Hearing in everyday life (HALLO)" a stereo tracking system is being used for analyzing the head movement of human patients during complex acoustic events. Together with the consideration of biosignals like skin conductance the speech comprehension and listening effort of persons with reduced hearing ability, especially in situations with background noise, is evaluated. For both projects the system design, accuracy aspects and results of practical tests are discussed.

  12. High precision laser direct microstructuring system based on bursts of picosecond pulses

    Science.gov (United States)

    Mur, Jaka; Petelin, Jaka; Osterman, Natan; Petkovšek, Rok

    2017-08-01

    We have developed an efficient, high precision system for direct laser microstructuring using fiber laser generated bursts of picosecond pulses. An advanced opto-mechanical system for beam deflection and sample movement, precise pulse energy control, and a custom built fiber laser with the pulse duration of 65 ps have been combined in a compact setup. The setup allows structuring of single-micrometer sized objects with a nanometer resolution of the laser beam positioning due to a combination of acousto-optical laser beam deflection and tight focusing. The precise synchronization of the fiber laser with the pulse burst repetition frequency of up to 100 kHz allowed a wide range of working parameters, including a tuneable number of pulses in each burst with the intra-burst repetition frequency of 40 MHz and delivering exactly one burst of pulses to every chosen position. We have demonstrated that tightly focused bursts of pulses significantly increase the ablation efficiency during the microstructuring of a copper layer and shorten the typical processing time compared to the single pulse per spot regime. We have used a simple short-pulse ablation model to describe our single pulse ablation data and developed an upgrade to the model to describe the ablation with bursts. Bursts of pulses also contribute to a high quality definition of structure edges and sides. The increased ablation efficiency at lower pulse energies compared to the single pulse per spot regime opens a window to utilize compact fiber lasers designed to operate at lower pulse energies, reducing the overall system complexity and size.

  13. Radio emission from Supernovae and High Precision Astrometry

    Science.gov (United States)

    Perez-Torres, M. A.

    1999-11-01

    The present thesis work makes contributions in two scientific fronts: differential astrometry over the largest angular scales ever attempted (approx. 15 arcdegrees) and numerical simulations of radio emission from very young supernovae. In the first part, we describe the results of the use of very-long-baseline interferometry (VLBI) in one experiment designed to measure with very high precision the angular distance between the radio sources 1150+812 (QSO) and 1803+784 (BL Lac). We observed the radio sources on 19 November 1993 using an intercontinental array of radio telescopes, which simultaneously recorded at 2.3 and 8.4 GHz. VLBI differential astrometry is capable, Nature allowing, of yielding source positions with precisions well below the milliarcsecond level. To achieve this precision, we first had to accurately model the rotation of the interferometric fringes via the most precise models of Earth Orientation Parameters (EOP; precession, polar motion and UT1, nutation). With this model, we successfully connected our phase delay data at both frequencies and, using difference astrometric techniques, determined the coordinates of 1803+784 relative to those of 1150+812-within the IERS reference frame--with an standard error of about 0.6 mas in each coordinate. We then corrected for several effects including propagation medium (mainly the atmosphere and ionosphere), and opacity and source-structure effects within the radio sources. We stress that our dual-frequency measurements allowed us to accurately subtract the ionosphere contribution from our data. We also used GPS-based TEC measurements to independently find the ionosphere contribution, and showed that these contributions agree with our dual-frequency measurements within about 2 standard deviations in the less favorables cases (the longest baselines), but are usually well within one standard deviation. Our estimates of the relative positions, whether using dual-frequency-based or GPS-based ionosphere

  14. Laser cooled ion beams and strongly coupled plasmas for precision experiments

    International Nuclear Information System (INIS)

    Bussmann, Michael

    2008-01-01

    This cumulative thesis summarizes experimental and theoretical results on cooling of ion beams using single-frequency, single-mode tabletop laser systems. It consists of two parts. One deals with experiments on laser-cooling of ion beams at relativistic energies, the other with simulations of stopping and sympathetic cooling of ions for precision in-trap experiments. In the first part, experimental results are presented on laser-cooling of relativistic C 3+ ion beams at a beam energy of 122 MeV/u, performed at the Experimental Storage Ring (ESR) at GSI. The main results presented in this thesis include the first attainment of longitudinally space-charge dominated relativistic ion beams using pure laser-cooling. The second part lists theoretical results on stopping and sympathetic cooling of ions in a laser-cooled one-component plasma of singly charged 24 Mg ions, which are confined in a three-dimensional harmonic trap potential. (orig.)

  15. Precision templates for gluing wire holding pieces to chamber frames

    International Nuclear Information System (INIS)

    Berdugo, J.; Burgos, C; Cerrada, M.

    1995-01-01

    In the present report we describe the procedure which has been used in order to optimize the precision obtained when positioning forward backward muon chamber sensor wire planes of the L3 experiment at CERN. With templates produced at CIEMAT a precision of about 10 microns. In sizes of the order of 3 meters. has been achieved. (Author) 2 refs

  16. A High-Precision Capacitive Sensor System for Displacement Measurements

    NARCIS (Netherlands)

    Yang, R.

    2015-01-01

    This thesis presents the theory, design and qualification of a precision capacitive sensor system for displacement measurement that require high resolution, high precision and simultaneously, low power consumption. The challenge to achieve the required performance has been taken care at both

  17. Prognostic and predictive biomarkers in colorectal cancer. Towards precision medicine

    NARCIS (Netherlands)

    Reimers, Marlies Suzanne

    2015-01-01

    The aim of this thesis was to define prognostic and predictive biomarkers in colorectal cancer for improved risk stratification and treatment benefit in the individual patient, with the introduction of precision medicine in the near future as the ultimate goal. By definition, precision medicine is

  18. Precision in Upper Lip Reconstructon. | Segun | Nigerian Journal of ...

    African Journals Online (AJOL)

    Both men were pleased. CONCLUSION: To achieve perfect symmetry, precise measurement must be used, using the normal side as a standard. Any discrepancy will still produce asymmetry. Keywords: Upper lip, Precision, Reconstructive surgery, Symmetry Nigerian Journal of Plastic Surgery Vol. 2 (2) 2006: pp. 11-14 ...

  19. Precision templates for glueing wire holding pieces to chamber frames

    International Nuclear Information System (INIS)

    Berdugo, J.; Burgos, C.; Cerrada, M.

    1995-09-01

    In the present report we describe the procedure which has been used in order to optimize the precision obtained when positioning forward backward muon chamber sensor wire planes of the L3 experiment at CERN. With templates produced at CIEMAT a precision of about 10 microns, in sizes of the order of 3 meters has been achieved

  20. Fluxgate magnetometry for precise mapping of the Earth's field

    DEFF Research Database (Denmark)

    Primdahl, Fritz; Merayo, José M.G.; Brauer, Peter

    2007-01-01

    The requirements for precise global mapping of the Earth's vector magnetic field from a high inclination LEO satellite needs a stable and precise vector magnetometer. Equally important are the measurement of the stellar attitude of the vector sensor and establishment of the calibration by onboard...

  1. The study of high precision neutron moisture gauge

    International Nuclear Information System (INIS)

    Liu Shengkang; Bao Guanxiong; Sang Hai; Zhu Yuzhen

    1993-01-01

    The principle, structure and calibration experiment of the high precision neutron moisture gauge (insertion type) are described. The gauge has been appraised. The precision of the measuring moisture of coke is lower than 0.5%, and the range of the measuring moisture is 2%-12%. The economic benefit of the gauge application is good

  2. What can we learn from high precision measurements of neutrino ...

    Indian Academy of Sciences (India)

    Many experiments are being planned to measure the neutrino mixing angles more precisely. In this note, the theoretical significance of a high precision measurement of these parameters is discussed. It is emphasized that they can provide crucial information about different ways to understand the origin of large atmospheric ...

  3. PRECISE - pregabalin in addition to usual care: Statistical analysis plan

    NARCIS (Netherlands)

    S. Mathieson (Stephanie); L. Billot (Laurent); C. Maher (Chris); A.J. McLachlan (Andrew J.); J. Latimer (Jane); B.W. Koes (Bart); M.J. Hancock (Mark J.); I. Harris (Ian); R.O. Day (Richard O.); J. Pik (Justin); S. Jan (Stephen); C.-W.C. Lin (Chung-Wei Christine)

    2016-01-01

    textabstractBackground: Sciatica is a severe, disabling condition that lacks high quality evidence for effective treatment strategies. This a priori statistical analysis plan describes the methodology of analysis for the PRECISE study. Methods/design: PRECISE is a prospectively registered, double

  4. Cerebral correlates of motor imagery of normal and precision gait

    NARCIS (Netherlands)

    Bakker, M.; Lange, F.P. de; Helmich, R.C.G.; Scheeringa, R.; Bloem, B.R.; Toni, I.

    2008-01-01

    We have examined the cerebral structures involved in motor imagery of normal and precision gait (i.e., gait requiring precise foot placement and increased postural control). We recorded cerebral activity with functional magnetic resonance imaging while subjects imagined walking along paths of two

  5. Precision two-photon spectroscopy of alkali elements

    Indian Academy of Sciences (India)

    2014-07-18

    Jul 18, 2014 ... A review of various techniques adopted for measuring absolute frequencies of the atomic transitions and precision measurements of isotope shifts and hyperfine structures (HFS) is presented. Some of the recent works on precision measurements of HFS constants of 6 2 S 1 / 2 level of 39 K and 41 K, 9 2 ...

  6. Precise FIA plot registration using field and dense LIDAR data

    Science.gov (United States)

    Demetrios Gatziolis

    2009-01-01

    Precise registration of forest inventory and analysis (FIA) plots is a prerequisite for an effective fusion of field data with ancillary spatial information, which is an approach commonly employed in the mapping of various forest parameters. Although the adoption of Global Positioning System technology has improved the precision of plot coordinates obtained during...

  7. How is precision regulated in maintaining trunk posture?

    NARCIS (Netherlands)

    Willigenburg, N.W.; Kingma, I.; van Dieen, J.H.

    2010-01-01

    Precision of limb control is associated with increased joint stiffness caused by antagonistic co-activation. The aim of this study was to examine whether this strategy also applies to precision of trunk postural control. To this end, thirteen subjects performed static postural tasks, aiming at a

  8. How is precision regulated in maintaining trunk posture?

    Science.gov (United States)

    Willigenburg, Nienke W; Kingma, Idsart; van Dieën, Jaap H

    2010-05-01

    Precision of limb control is associated with increased joint stiffness caused by antagonistic co-activation. The aim of this study was to examine whether this strategy also applies to precision of trunk postural control. To this end, thirteen subjects performed static postural tasks, aiming at a target object with a cursor that responded to 2D trunk angles. By manipulating target dimensions, different levels of precision were imposed in the frontal and sagittal planes. Trunk angle and electromyography (EMG) of abdominal and back muscles were recorded. Repeated measures ANOVAs revealed significant effects of target dimensions on kinematic variability in both movement planes. Specifically, standard deviation (SD) of trunk angle decreased significantly when target size in the same direction decreased, regardless of the precision demands in the other direction. Thus, precision control of trunk posture was directionally specific. However, no consistent effect of precision demands was found on trunk muscle activity, when averaged over time series. Therefore, it was concluded that stiffness regulation by antagonistic co-activation was not used to meet increased precision demands in trunk postural control. Instead, results from additional analyses suggest that precision of trunk angle was controlled in a feedback mode.

  9. Research Note: Precision and accuracy of sward height distributions ...

    African Journals Online (AJOL)

    African Journal of Range and Forage Science ... Research Note: Precision and accuracy of sward height distributions. CD Morris, PJK Zacharias ... The effect of sample size on the precision and accuracy of parameters of sward height distributions was examined by drawing sub-samples (n = 10) of increasing sample size ...

  10. Mathematical Precision of Pitch Gaps in Tribal Tonal

    African Journals Online (AJOL)

    SOCIAL PATHOLOGY OF CLEFT PALATE IN THE AFRICAN: MATHEMATICAL PRECISION OF PITCH GAPS IN TRIBAL TONAL ... with Tonic Solfa precision. I have done this both in tribal tonal linguistics and in ... in English. My native ear enables me to hear 4 pitches in the word “Agriculture” in Queen's English [high.

  11. UAV low-altitude remote sensing for precision weed management

    Science.gov (United States)

    Precision weed management, an application of precision agriculture, accounts for within-field variability of weed infestation and herbicide damage. Unmanned aerial vehicles (UAVs) provide a unique platform for remote sensing of field crops. They are more efficient and flexible than manned agricultur...

  12. Water vapour retrieval using the Precision Solar Spectroradiometer

    Science.gov (United States)

    Raptis, Panagiotis-Ioannis; Kazadzis, Stelios; Gröbner, Julian; Kouremeti, Natalia; Doppler, Lionel; Becker, Ralf; Helmis, Constantinos

    2018-02-01

    The Precision Solar Spectroradiometer (PSR) is a new spectroradiometer developed at Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD-WRC), Davos, measuring direct solar irradiance at the surface, in the 300-1020 nm spectral range and at high temporal resolution. The purpose of this work is to investigate the instrument's potential to retrieve integrated water vapour (IWV) using its spectral measurements. Two different approaches were developed in order to retrieve IWV: the first one uses single-channel and wavelength measurements, following a theoretical water vapour high absorption wavelength, and the second one uses direct sun irradiance integrated at a certain spectral region. IWV results have been validated using a 2-year data set, consisting of an AERONET sun-photometer Cimel CE318, a Global Positioning System (GPS), a microwave radiometer profiler (MWP) and radiosonde retrievals recorded at Meteorological Observatorium Lindenberg, Germany. For the monochromatic approach, better agreement with retrievals from other methods and instruments was achieved using the 946 nm channel, while for the spectral approach the 934-948 nm window was used. Compared to other instruments' retrievals, the monochromatic approach leads to mean relative differences up to 3.3 % with the coefficient of determination (R2) being in the region of 0.87-0.95, while for the spectral approach mean relative differences up to 0.7 % were recorded with R2 in the region of 0.96-0.98. Uncertainties related to IWV retrieval methods were investigated and found to be less than 0.28 cm for both methods. Absolute IWV deviations of differences between PSR and other instruments were determined the range of 0.08-0.30 cm and only in extreme cases would reach up to 15 %.

  13. Tests of FARICH prototype with precise photon position detection

    Energy Technology Data Exchange (ETDEWEB)

    Barnyakov, A.Yu. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Barnyakov, M.Yu. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Novosibirsk State Technical University, Novosibirsk (Russian Federation); Basok, I.Yu. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Blinov, V.E. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Novosibirsk State Technical University, Novosibirsk (Russian Federation); Bobrovnikov, V.S.; Borodenko, A.A.; Buzykaev, A.R. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Danilyuk, A.F. [Boreskov Institute of Catalysis SB RAS, Novosibirsk (Russian Federation); Degenhardt, C.; Dorscheid, R. [Philips Digital Photon Counting, Aachen (Germany); Finogeev, D.A. [Institute of Nuclear Research RAS, Moscow (Russian Federation); Frach, T. [Philips Digital Photon Counting, Aachen (Germany); Gulevich, V.V. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Karavicheva, T.L. [Institute of Nuclear Research RAS, Moscow (Russian Federation); Kasyanenko, P.V. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Kononov, S.A. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Novosibirsk State University, Novosibirsk (Russian Federation); Korda, D.V. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Novosibirsk State Technical University, Novosibirsk (Russian Federation); Kravchenko, E.A., E-mail: E.A.Kravchenko@inp.nsk.su [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Novosibirsk State University, Novosibirsk (Russian Federation); Kudryavtsev, V.N. [Budker Institute of Nuclear Physics SB RAS, Novosibirsk (Russian Federation); Kurepin, A.B. [Institute of Nuclear Research RAS, Moscow (Russian Federation); and others

    2014-12-01

    In June 2012 a FARICH prototype from Philips Digital Photon Counting (PDPC) based on a photon camera with dimensions of 200×200 mm has been tested at CERN. Remarkable particle separation has been achieved with a 4-layer aerogel sample: the π/K separation at a 6 GeV/c momentum is 3.5σ, the μ/π separation is 5.3σ at 1 GeV/c. The analysis of the data has shown that the main contribution to the accuracy of the ring radius measurement comes from aerogel. The development of focusing aerogels is proceeding in two main directions: tuning of production technology of multilayer blocks and development of a new production method with continuous density (refractive index) gradient along the block depth. The beam test was carried out in December 2012–January 2013 at the electron beam test facility at the VEPP-4 M e{sup +}e{sup −} collider. The goal of this test was to measure different single layer and focusing aerogel samples, both multilayer and gradient. Aerogel samples were tested with a PDPC FARICH prototype. A part of DPC SPADs in each pixel was disabled to form an active area of 1×1 mm{sup 2}. The collected data proved that gradient aerogel samples focus Cherenkov light. - Highlights: • The first aerogel tiles with specified profile of refractive index along the block depth are produced. • To get 300 μm photon position resolution 92% of individual micro-cells were inhibited in a DPC pixel. • The first tests with ‘gradient’ radiators and DPC detector working in precise detection mode were done.

  14. HIGH-PRECISION ASTROMETRY WITH A DIFFRACTIVE PUPIL TELESCOPE

    International Nuclear Information System (INIS)

    Guyon, Olivier; Eisner, Josh A.; Angel, Roger; Woolf, Neville J.; Bendek, Eduardo A.; Milster, Thomas D.; Mark Ammons, S.; Shao, Michael; Shaklan, Stuart; Levine, Marie; Nemati, Bijan; Pitman, Joe; Woodruff, Robert A.; Belikov, Ruslan

    2012-01-01

    Astrometric detection and mass determination of Earth-mass exoplanets require sub-μas accuracy, which is theoretically possible with an imaging space telescope using field stars as an astrometric reference. The measurement must, however, overcome astrometric distortions, which are much larger than the photon noise limit. To address this issue, we propose to generate faint stellar diffraction spikes using a two-dimensional grid of regularly spaced small dark spots added to the surface of the primary mirror (PM). Accurate astrometric motion of the host star is obtained by comparing the position of the spikes to the background field stars. The spikes do not contribute to scattered light in the central part of the field and therefore allow unperturbed coronagraphic observation of the star's immediate surroundings. Because the diffraction spikes are created on the PM and imaged on the same focal plane detector as the background stars, astrometric distortions affect equally the diffraction spikes and the background stars and are therefore calibrated. We describe the technique, detail how the data collected by the wide-field camera are used to derive astrometric motion, and identify the main sources of astrometric error using numerical simulations and analytical derivations. We find that the 1.4 m diameter telescope, 0.3 deg 2 field we adopt as a baseline design achieves 0.2 μas single measurement astrometric accuracy. The diffractive pupil concept thus enables sub-μas astrometry without relying on the accurate pointing, external metrology, or high-stability hardware required with previously proposed high-precision astrometry concepts.

  15. Research Of Airborne Precision Spacing to Improve Airport Arrival Operations

    Science.gov (United States)

    Barmore, Bryan E.; Baxley, Brian T.; Murdoch, Jennifer L.

    2011-01-01

    In September 2004, the European Organization for the Safety of Air Navigation (EUROCONTROL) and the United States Federal Aviation Administration (FAA) signed a Memorandum of Cooperation to mutually develop, modify, test, and evaluate systems, procedures, facilities, and devices to meet the need for safe and efficient air navigation and air traffic control in the future. In the United States and Europe, these efforts are defined within the architectures of the Next Generation Air Transportation System (NextGen) Program and Single European Sky Air Traffic Management Research (SESAR) Program respectively. Both programs have identified Airborne Spacing as a critical component, with Automatic Dependent Surveillance Broadcast (ADS-B) as a key enabler. Increased interest in reducing airport community noise and the escalating cost of aviation fuel has led to the use of Continuous Descent Arrival (CDA) procedures to reduce noise, emissions, and fuel usage compared to current procedures. To provide these operational enhancements, arrival flight paths into terminal areas are planned around continuous vertical descents that are closer to an optimum trajectory than those in use today. The profiles are designed to be near-idle descents from cruise altitude to the Final Approach Fix (FAF) and are typically without any level segments. By staying higher and faster than conventional arrivals, CDAs also save flight time for the aircraft operator. The drawback is that the variation of optimized trajectories for different types and weights of aircraft requires the Air Traffic Controller to provide more airspace around an aircraft on a CDA than on a conventional arrival procedure. This additional space decreases the throughput rate of the destination airport. Airborne self-spacing concepts have been developed to increase the throughput at high-demand airports by managing the inter-arrival spacing to be more precise and consistent using on-board guidance. It has been proposed that the

  16. Assessment of precision and reproducibility of a new myograph

    Directory of Open Access Journals (Sweden)

    Piepenbrock Siegfried

    2007-12-01

    Full Text Available Abstract Background The physiological characteristics of muscle activity and the assessment of muscle strength represent important diagnostic information. There are many devices that measure muscle force in humans, but some require voluntary contractions, which are difficult to assess in weak or unconscious patients who are unable to complete a full range of voluntary force assessment tasks. Other devices, which obtain standard muscle contractions by electric stimulations, do not have the technology required to induce and measure reproducible valid contractions at the optimum muscle length. Methods In our study we used a newly developed diagnostic device which measures accurately the reproducibility and time-changed-variability of the muscle force in an individual muscle. A total of 500 in-vivo measurements of supra-maximal isometric single twitch contractions were carried out on the musculus adductor pollicis of 5 test subjects over 10 sessions, with ten repetitions per session. The same protocol was performed on 405 test subjects with two repetitions each to determine a reference-interval on healthy subjects. Results Using our test setting, we found a high reproducibility of the muscle contractions of each test subject. The precision of the measurements performed with our device was 98.74%. Only two consecutive measurements are needed in order to assess a real, representative individual value of muscle force. The mean value of the force of contraction was 9.51 N and the 95% reference interval was 4.77–14.25 N. Conclusion The new myograph is a highly reliable measuring device with which the adductor pollicis can be investigated at the optimum length. It has the potential to become a reliable and valid tool for diagnostic in the clinical setting and for monitoring neuromuscular diseases.

  17. Joint Estimation of Multiple Precision Matrices with Common Structures.

    Science.gov (United States)

    Lee, Wonyul; Liu, Yufeng

    Estimation of inverse covariance matrices, known as precision matrices, is important in various areas of statistical analysis. In this article, we consider estimation of multiple precision matrices sharing some common structures. In this setting, estimating each precision matrix separately can be suboptimal as it ignores potential common structures. This article proposes a new approach to parameterize each precision matrix as a sum of common and unique components and estimate multiple precision matrices in a constrained l 1 minimization framework. We establish both estimation and selection consistency of the proposed estimator in the high dimensional setting. The proposed estimator achieves a faster convergence rate for the common structure in certain cases. Our numerical examples demonstrate that our new estimator can perform better than several existing methods in terms of the entropy loss and Frobenius loss. An application to a glioblastoma cancer data set reveals some interesting gene networks across multiple cancer subtypes.

  18. Modeling and Positioning of a PZT Precision Drive System.

    Science.gov (United States)

    Liu, Che; Guo, Yanling

    2017-11-08

    The fact that piezoelectric ceramic transducer (PZT) precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circuit based on Position Sensitive Detector (PSD) is constructed, followed by the establishment of system closed-loop control and creep control models. An XL-80 laser interferometer (Renishaw, Wotton-under-Edge, UK) was used to measure the performance of the precision drive system, showing that system modeling and control algorithms were correct, with the requirements for precision positioning of the drive system satisfied.

  19. Modeling and Positioning of a PZT Precision Drive System

    Directory of Open Access Journals (Sweden)

    Che Liu

    2017-11-01

    Full Text Available The fact that piezoelectric ceramic transducer (PZT precision drive systems in 3D printing are faced with nonlinear problems with respect to positioning, such as hysteresis and creep, has had an extremely negative impact on the precision of laser focusing systems. To eliminate the impact of PZT nonlinearity during precision drive movement, mathematical modeling and theoretical analyses of each module comprising the system were carried out in this study, a micro-displacement measurement circuit based on Position Sensitive Detector (PSD is constructed, followed by the establishment of system closed-loop control and creep control models. An XL-80 laser interferometer (Renishaw, Wotton-under-Edge, UK was used to measure the performance of the precision drive system, showing that system modeling and control algorithms were correct, with the requirements for precision positioning of the drive system satisfied.

  20. Potentials and prospects of precision agriculture in pakistan - a review

    International Nuclear Information System (INIS)

    Mahmood, H.S.; Ahmad, T.; Saeed, M.A.; Iqbal, M.

    2013-01-01

    Precision agriculture is to fine-tune the agricultural production system by emergence and convergence of several information-based technologies for enhancing profit and reducing environmental risks. These technologies have demonstrated to provide benefits to farmers as well as reduced environmental stresses in the developed world. Present paper provides an overview of precision agriculture and examines the potentials, prospects, implications, issues and relevance of precision agricultural applications in Pakistani agricultural system. There is a scope of many precision technologies to be implemented in the country. In this perspective, farmers and government authorities should look forward to adopt new and sustainable technologies to increase the efficiency of available resources and reduce the input costs. Before this, the effectiveness of precision technologies needs to be realised in Pakistan through field experiments and land management practices. (author)

  1. Note: High precision measurements using high frequency gigahertz signals

    Science.gov (United States)

    Jin, Aohan; Fu, Siyuan; Sakurai, Atsunori; Liu, Liang; Edman, Fredrik; Pullerits, Tõnu; Öwall, Viktor; Karki, Khadga Jung

    2014-12-01

    Generalized lock-in amplifiers use digital cavities with Q-factors as high as 5 × 108 to measure signals with very high precision. In this Note, we show that generalized lock-in amplifiers can be used to analyze microwave (giga-hertz) signals with a precision of few tens of hertz. We propose that the physical changes in the medium of propagation can be measured precisely by the ultra-high precision measurement of the signal. We provide evidence to our proposition by verifying the Newton's law of cooling by measuring the effect of change in temperature on the phase and amplitude of the signals propagating through two calibrated cables. The technique could be used to precisely measure different physical properties of the propagation medium, for example, the change in length, resistance, etc. Real time implementation of the technique can open up new methodologies of in situ virtual metrology in material design.

  2. Precision Measurements of Tau Lepton Decays

    Energy Technology Data Exchange (ETDEWEB)

    Nugent, Ian M. [Univ. of Victoria, BC (Canada)

    2008-01-01

    Using data collected with the BABAR detector at the SLAC PEP-II electron-positron storage ring operating at a centre-of-mass energy near 10.58 GeV, the branching fractions B(τ- → π-π-π+ντ) =(8.83±0.01±0.13)%, B(τ- → K-π-π+ντ) =(0.273± 0.002 ± 0.009)%, B(τ- → K-π-K+ντ) =(0.1346 ± 0.0010 ± 0.0036)%, and B(τ- → K-K-K+ντ) =(1.58 ± 0.13 ± 0.12) × 10-5 are measured where the uncertainties are statistical and systematic, respectively. The invariant mass distribution for the τ- → π-π-π+ντ , τ- → K-π-π+ντ , τ- → K-π-K+ντ and τ- → K-K-K+ντ decays are unfolded to correct for detector effects. A measurement of B(τ- → φπ-ντ ) =(3.42±0.55±0.25)×10-5, a measurement of B(τ- → φK-ντ) =(3.39±0.20±0.28)× 10-5 and an upper limit on B(τ- → K-K-K+ντ [ex.φ]) ≤ 2.5 × 10-6@90%CL are determined from a binned maximum likelihood fit of the τ- → K-π-K+ντ and τ- → K-K-K+ντ K+K- invariant mass distributions. The branching ratio B(τ-→K-ντ )/ B(τ-→π-ντ ) is measured to be (6.531±0.056±0.093)×10-2 from which |Vus| is determined to be 0.2255 ± 0.0023. The branching ratio B(τ-→μ-ντ $\\bar{v}$μ)/ B(τ-→e-ντ $\\bar{v}$e) =(9.796 ± 0.016 ± 0.035) × 10-1 is measured enabling a precision test of the Standard Model assumption of

  3. A speech recognition system for data collection in precision agriculture

    Science.gov (United States)

    Dux, David Lee

    Agricultural producers have shown interest in collecting detailed, accurate, and meaningful field data through field scouting, but scouting is labor intensive. They use yield monitor attachments to collect weed and other field data while driving equipment. However, distractions from using a keyboard or buttons while driving can lead to driving errors or missed data points. At Purdue University, researchers have developed an ASR system to allow equipment operators to collect georeferenced data while keeping hands and eyes on the machine during harvesting and to ease georeferencing of data collected during scouting. A notebook computer retrieved locations from a GPS unit and displayed and stored data in Excel. A headset microphone with a single earphone collected spoken input while allowing the operator to hear outside sounds. One-, two-, or three-word commands activated appropriate VBA macros. Four speech recognition products were chosen based on hardware requirements and ability to add new terms. After training, speech recognition accuracy was 100% for Kurzweil VoicePlus and Verbex Listen for the 132 vocabulary words tested, during tests walking outdoors or driving an ATV. Scouting tests were performed by carrying the system in a backpack while walking in soybean fields. The system recorded a point or a series of points with each utterance. Boundaries of points showed problem areas in the field and single points marked rocks and field corners. Data were displayed as an Excel chart to show a real-time map as data were collected. The information was later displayed in a GIS over remote sensed field images. Field corners and areas of poor stand matched, with voice data explaining anomalies in the image. The system was tested during soybean harvest by using voice to locate weed patches. A harvester operator with little computer experience marked points by voice when the harvester entered and exited weed patches or areas with poor crop stand. The operator found the

  4. Characterization of corticospinal activation of finger motor neurons during precision and power grip in humans

    DEFF Research Database (Denmark)

    Svane, Christian; Forman, Christian Riis; Nielsen, Jens Bo

    2018-01-01

    Direct and indirect corticospinal pathways to finger muscles may play a different role in control of the upper extremity. We used transcranial magnetic stimulation (TMS) and coherence analysis to characterize the corticospinal drive to the first dorsal interosseous (FDI) and abductor pollicis bre...... brevis (APB) when active during a precision and power grip task. In experiment 1, single motor units were recorded during precision grip and power grip in 20 adults (25.2 ± 7.1 years). Post-stimulus time histograms (PSTH) were obtained following TMS. In experiment 2, coherence and cross...... system) is equally involved in the control of both tasks. The data do not support that indirect pathways would make a larger contribution to power grip....

  5. Double resonance calibration of g factor standards: Carbon fibers as a high precision standard.

    Science.gov (United States)

    Herb, Konstantin; Tschaggelar, Rene; Denninger, Gert; Jeschke, Gunnar

    2018-04-01

    The g factor of paramagnetic defects in commercial high performance carbon fibers was determined by a double resonance experiment based on the Overhauser shift due to hyperfine coupled protons. Our carbon fibers exhibit a single, narrow and perfectly Lorentzian shaped ESR line and a g factor slightly higher than g free with g=2.002644=g free ·(1+162ppm) with a relative uncertainty of 15ppm. This precisely known g factor and their inertness qualify them as a high precision g factor standard for general purposes. The double resonance experiment for calibration is applicable to other potential standards with a hyperfine interaction averaged by a process with very short correlation time. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Estimated venous return surface and cardiac output curve precisely predicts new hemodynamics after volume change.

    Science.gov (United States)

    Sugimachi, Masaru; Sunagawa, Kenji; Uemura, Kazunori; Kamiya, Atsunori; Shimizu, Shuji; Inagaki, Masashi; Shishido, Toshiaki

    2010-01-01

    In our extended Guyton's model, the ability of heart to pump blood is characterized by a cardiac output curve and the ability of vasculature to pool blood by a venous return surface. These intersect in a three-dimensional coordinate system at the operating right atrial pressure, left atrial pressure, and cardiac output. The baseline cardiac output curve and venous return surface and their changes after volume change would predict new hemodynamics. The invasive methods needed to precisely characterize cardiac output curve and venous return surface led us to aim at estimating cardiac output curve and venous return surface from a single hemodynamic measurement. Using the average values for two logarithmic function parameters, and for two slopes of a surface, we were able to estimate cardiac output curve and venous return surface. The estimated curve and surface predicted new hemodynamics after volume change precisely.

  7. Active and Precise Control of Microdroplet Division Using Horizontal Pneumatic Valves in Bifurcating Microchannel

    Directory of Open Access Journals (Sweden)

    Shuichi Shoji

    2013-05-01

    Full Text Available This paper presents a microfluidic system for the active and precise control of microdroplet division in a micro device. Using two horizontal pneumatic valves formed at downstream of bifurcating microchannel, flow resistances of downstream channels were variably controlled. With the resistance control, volumetric ratio of downstream flows was changed and water-in-oil microdroplets were divided into two daughter droplets of different volume corresponding to the ratio. The microfluidic channels and pneumatic valves were fabricated by single-step soft lithography process of PDMS (polydimethylsiloxane using SU-8 mold. A wide range control of the daughter droplets’ volume ratio was achieved by the simple channel structure. Volumetric ratio between large and small daughter droplets are ranged from 1 to 70, and the smallest droplet volume of 14 pL was obtained. The proposed microfluidic device is applicable for precise and high throughput droplet based digital synthesis.

  8. Evaluation of the Precision ID Ancestry Panel for crime case work

    DEFF Research Database (Denmark)

    Pereira, Vania; Mogensen, Helle S; Børsting, Claus

    2017-01-01

    single MPS assay. This reduces both the amount of sample used and the time of the investigations. This study assessed the utility of the Precision ID Ancestry Panel (Thermo Fisher Scientific, Waltham, USA) in forensic genetics. This assay was developed for the Ion Torrent PGM™ System and genotypes 165...... ancestry informative SNPs. The performance of the assay and the accompanying software solution for ancestry inference was assessed by typing 142 Danes and 98 Somalis. Locus balance, heterozygote balance, and noise levels were calculated and future analysis criteria for crime case work were estimated....... Overall, the Precision ID Ancestry Panel performed well, and only minor changes to the recommended protocol were implemented. Three out of the 165 loci (rs459920, rs7251928, and rs7722456) had consistently poor performance, mainly due to misalignment of homopolymeric stretches. We suggest that these loci...

  9. Dynamic metrology and data processing for precision freeform optics fabrication and testing

    Science.gov (United States)

    Aftab, Maham; Trumper, Isaac; Huang, Lei; Choi, Heejoo; Zhao, Wenchuan; Graves, Logan; Oh, Chang Jin; Kim, Dae Wook

    2017-06-01

    Dynamic metrology holds the key to overcoming several challenging limitations of conventional optical metrology, especially with regards to precision freeform optical elements. We present two dynamic metrology systems: 1) adaptive interferometric null testing; and 2) instantaneous phase shifting deflectometry, along with an overview of a gradient data processing and surface reconstruction technique. The adaptive null testing method, utilizing a deformable mirror, adopts a stochastic parallel gradient descent search algorithm in order to dynamically create a null testing condition for unknown freeform optics. The single-shot deflectometry system implemented on an iPhone uses a multiplexed display pattern to enable dynamic measurements of time-varying optical components or optics in vibration. Experimental data, measurement accuracy / precision, and data processing algorithms are discussed.

  10. Role of low-energy observables in precision Higgs boson analyses

    Energy Technology Data Exchange (ETDEWEB)

    Petrov, Alexey A. [Wayne State Univ., Detroit, MI (United States); Univ. of Michigan, Ann Arbor, MI (United States); Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States); Pokorski, Stefan [Univ. of Warsaw, Warsaw (Poland); Wells, James D. [Univ. of Michigan, Ann Arbor, MI (United States); Zhang, Zhengkang [Univ. of Michigan, Ann Arbor, MI (United States)

    2015-04-02

    A conventional approach to precision calculations of Higgs boson observables uses quark masses mc and mb as inputs. However, quark masses are single numbers that hide a variety of low-energy data from which they are extracted, and also hide the various sources of theoretical uncertainties and correlations with additional input parameters such as αs. Higher-precision calculations, which are needed to give meaning to future measurements, require more direct engagement with the low-energy data in a global analysis. As a result, we present an initial calculation in this direction, which illustrates the procedure and reveals some of the theory uncertainties that challenge subpercent determinations of Higgs boson partial widths.

  11. Preprocessing of the GPS Raw Data for the Precision Orbit Determination by Dgps Technique

    Directory of Open Access Journals (Sweden)

    Bo-Yeon Moon

    2002-06-01

    Full Text Available This article investigates the problem of data preprocessing for the precision orbit determination (POD of low earth orbit satellite using GPS raw data. Several data preprocessing algorithms have been developed to edit the GPS data automatically such that outlier deletion, cycle slip identification and correction, and time tag error correction. The GPS data are precisely edited for the accuracy of POD. Some methods of data preprocessing are restricted to the rate of the collections of the pseudorange and carrier phase measurements. This study considers the preprocessing efficiency varied with the rate, the quality of receiver and the altitude of the satellite's orbit. We also propose the proper methods in accordance with the rate for single frequency and dual frequency receivers.

  12. Precise calculations in simulations of the interaction of low energy neutrons with nano-dispersed media

    Energy Technology Data Exchange (ETDEWEB)

    Artem’ev, V. A., E-mail: niitm@inbox.ru [Research Institute of Materials Technology (Russian Federation); Nezvanov, A. Yu. [Moscow State Industrial University (Russian Federation); Nesvizhevsky, V. V. [Institut Max von Laue—Paul Langevin (France)

    2016-01-15

    We discuss properties of the interaction of slow neutrons with nano-dispersed media and their application for neutron reflectors. In order to increase the accuracy of model simulation of the interaction of neutrons with nanopowders, we perform precise quantum mechanical calculation of potential scattering of neutrons on single nanoparticles using the method of phase functions. We compare results of precise calculations with those performed within first Born approximation for nanodiamonds with the radius of 2–5 nm and for neutron energies 3 × 10{sup -7}–10{sup -3} eV. Born approximation overestimates the probability of scattering to large angles, while the accuracy of evaluation of integral characteristics (cross sections, albedo) is acceptable. Using Monte-Carlo method, we calculate albedo of neutrons from different layers of piled up diamond nanopowder.

  13. ACADEMIC TRAINING: Probing nature with high precision; particle traps, laser spectroscopy and optical combs

    CERN Multimedia

    Françoise Benz

    2002-01-01

    17, 18, 19 June LECTURE SERIES from 11.00 to 12.00 hrs - Auditorium, bldg. 500 Probing nature with high precision; particle traps, laser spectroscopy and optical combs by G. GABRIELSE / Harvard University, USA Experiments with atomic energy scales probe nature and its symmetries with exquisite precision. Particle traps allow the manipulation of single charged particles for months at a time, allow the most accurate comparison of theory and experiment, and promise to allow better measurement of fundamental quantities like the fine structure constant. Ions and atoms can be probed with lasers that are phase locked to microwave frequency standards via optical combs, thus calibrating optical sources in terms of the official cesium second. A series of three lectures will illustrate what can be measured and discuss key techniques.  ACADEMIC TRAINING Françoise Benz Tel. 73127 francoise.benz@cern.ch

  14. Upgrades for the Precision Proton Spectrometer at the LHC: Precision Timing and Tracking Detectors

    CERN Document Server

    Gallinaro, Michele

    2017-01-01

    The CMS-TOTEM Precision Proton Spectrometer (CT-PPS) is an approved project to add tracking and timing information at approximately $\\pm$210~m from the interaction point around the CMS detector. It is designed to operate at high luminosity with up to 50 interactions per 25~ns bunch crossing to perform measurements of e.g. the quartic gauge couplings and search for rare exclusive processes. During 2016, CT-PPS took data in normal high-luminosity proton-proton LHC collisions. In the coming years, high radiation doses and large multiple-vertex interactions will represent difficult challenges that resemble those of the high-luminosity LHC program. A coordinated effort of detector upgrades with the goal of reaching the physics goals while mitigating the degradation effects is under way. Upgrades to the tracking and timing detectors are discussed.

  15. Precision templates for gluing wire holding pieces to chamber frames; Plantillas de precision para la construccion de detectores de muones

    Energy Technology Data Exchange (ETDEWEB)

    Berdugo, J.; Burgos, C; Cerrada, M.

    1995-07-01

    In the present report we describe the procedure which has been used in order to optimize the precision obtained when positioning forward backward muon chamber sensor wire planes of the L3 experiment at CERN. With templates produced at CIEMAT a precision of about 10 microns. In sizes of the order of 3 meters. has been achieved. (Author) 2 refs.

  16. Program Guide for Basic Precision Machining 8754000 (IN48.052300) and Precision Machining MTR0470 (IN48.050300).

    Science.gov (United States)

    University of South Florida, Tampa. Dept. of Adult and Vocational Education.

    This competency-based program guide provides course content information and procedures for secondary schools, postsecondary vocational schools, and community colleges in Florida that conduct programs in basic precision machining and precision machining. The first section is on legal authority, which applies to all vocational education programs in…

  17. Micro-precise spatiotemporal delivery system embedded in 3D printing for complex tissue regeneration.

    Science.gov (United States)

    Tarafder, Solaiman; Koch, Alia; Jun, Yena; Chou, Conrad; Awadallah, Mary R; Lee, Chang H

    2016-04-25

    Three dimensional (3D) printing has emerged as an efficient tool for tissue engineering and regenerative medicine, given its advantages for constructing custom-designed scaffolds with tunable microstructure/physical properties. Here we developed a micro-precise spatiotemporal delivery system embedded in 3D printed scaffolds. PLGA microspheres (μS) were encapsulated with growth factors (GFs) and then embedded inside PCL microfibers that constitute custom-designed 3D scaffolds. Given the substantial difference in the melting points between PLGA and PCL and their low heat conductivity, μS were able to maintain its original structure while protecting GF's bioactivities. Micro-precise spatial control of multiple GFs was achieved by interchanging dispensing cartridges during a single printing process. Spatially controlled delivery of GFs, with a prolonged release, guided formation of multi-tissue interfaces from bone marrow derived mesenchymal stem/progenitor cells (MSCs). To investigate efficacy of the micro-precise delivery system embedded in 3D printed scaffold, temporomandibular joint (TMJ) disc scaffolds were fabricated with micro-precise spatiotemporal delivery of CTGF and TGFβ3, mimicking native-like multiphase fibrocartilage. In vitro, TMJ disc scaffolds spatially embedded with CTGF/TGFβ3-μS resulted in formation of multiphase fibrocartilaginous tissues from MSCs. In vivo, TMJ disc perforation was performed in rabbits, followed by implantation of CTGF/TGFβ3-μS-embedded scaffolds. After 4 wks, CTGF/TGFβ3-μS embedded scaffolds significantly improved healing of the perforated TMJ disc as compared to the degenerated TMJ disc in the control group with scaffold embedded with empty μS. In addition, CTGF/TGFβ3-μS embedded scaffolds significantly prevented arthritic changes on TMJ condyles. In conclusion, our micro-precise spatiotemporal delivery system embedded in 3D printing may serve as an efficient tool to regenerate complex and inhomogeneous tissues.

  18. Geometrical precision of 3DP casting form for founding gears

    Directory of Open Access Journals (Sweden)

    T. Markowski

    2010-01-01

    Full Text Available The article presents analysis of geometrical precision of casting form made by means of 3DP method. Three dimentional printing is a universal method of rapid prototyping which can be used to make tools – castings forms as a Rapid Tooling method. By means of this method in direct incremental process a casting form of spur gear was created. Precision of creating the form by 3DP method depends on different factors. Technological factors depending on machine operator include: the thickness of the layer and placing the model in working space. The precision of creating the model also depends on preparing the printer for work: the condition and calibration of printing heads, the condition of the printing unit slide guides and preparing the working space. Three dimentional printer Z510 Spectrum was prepared for work in a way assuring the greatest precision of created models. Technological parameters responsible for precision were set on maximum values. The aim of the research was defining the precision of casting form generated by 3DP Rapid Prototyping Method. The research was made by means of coordinate measuring machine Wenzel LH87. The measuring machine software was used to compare the outcome of the measurement to nominal model 3D-CAD. The problem of tool precision of casting forms generated by Rapid Tooling is rarely considered in literature covering rapid prototyping and casting technologies. That is why the research presented in this article isan original work in the technological and practical aspect.

  19. A Precision Measurement of the W Boson Mass with 1 Inverse Femtobarn of DZero Run IIa Data

    Energy Technology Data Exchange (ETDEWEB)

    Osta, Jyotsna [Univ. of Notre Dame, IN (United States)

    2009-12-01

    This thesis is a detailed presentation of a precision measurement of the mass of the W boson. It has been obtained by analyzing W → ev decays. The data used for this analysis was collected from 2002 to 2006 with the D0 detector, during Run IIa of the Fermilab Tevatron collider. It corresponds to a total integrated luminosity of 1 fb-1. With a sample of 499,830 W → ev candidate events, we obtain a mass measurement of MW = 80.401 ± 0.043 GeV. This is the most precise measurement from a single experiment to date.

  20. A Portable Single Axis Magnetic Gradiometer

    DEFF Research Database (Denmark)

    Merayo, José M.G.; Petersen, Jan Raagaard; Nielsen, Otto V

    2001-01-01

    The single axis magnetic gradiometer based on two compact detector compensation (CDC) fluxgate ringcore sensors separated 20 cm is described. Despite its high stability and precision better than 1 nT, the calibration procedures are not straightforward. Firstly, the mono-axial measurement does not...... measurements is achieved by using a magnetic dipole of strength 2 mAm(2). In a coil facility, the gradient can be determined with an accuracy of 0.3 nT/m(RMS)....