WorldWideScience

Sample records for single point failure

  1. Program computes single-point failures in critical system designs

    Science.gov (United States)

    Brown, W. R.

    1967-01-01

    Computer program analyzes the designs of critical systems that will either prove the design is free of single-point failures or detect each member of the population of single-point failures inherent in a system design. This program should find application in the checkout of redundant circuits and digital systems.

  2. Failure mechanisms in single-point incremental forming of metals

    DEFF Research Database (Denmark)

    Silva, Maria B.; Nielsen, Peter Søe; Bay, Niels

    2011-01-01

    The last years saw the development of two different views on how failure develops in single-point incremental forming (SPIF). Today, researchers are split between those claiming that fracture is always preceded by necking and those considering that fracture occurs with suppression of necking. Eac...... and involves independent determination of formability limits by necking and fracture using tensile and hydraulic bulge tests in conjunction with SPIF of benchmark shapes under laboratory conditions.......The last years saw the development of two different views on how failure develops in single-point incremental forming (SPIF). Today, researchers are split between those claiming that fracture is always preceded by necking and those considering that fracture occurs with suppression of necking. Each...... on formability limits and development of fracture. The unified view conciliates the aforementioned different explanations on the role of necking in fracture and is consistent with the experimental observations that have been reported in the past years. The work is performed on aluminium AA1050-H111 sheets...

  3. Single-point incremental forming and formability-failure diagrams

    DEFF Research Database (Denmark)

    Silva, M.B.; Skjødt, Martin; Atkins, A.G.

    2008-01-01

    In a recent work [1], the authors constructed a closed-form analytical model that is capable of dealing with the fundamentals of single point incremental forming and explaining the experimental and numerical results published in the literature over the past couple of years. The model is based on ...

  4. Plastic flow and failure in single point incremental forming of PVC sheets

    Directory of Open Access Journals (Sweden)

    P. A. F. Martins

    2014-05-01

    Full Text Available This paper presents an innovative and effective methodology to characterize plastic flow and failure in single point incremental forming (SPIF of polymers that allows determining the stresses and the accumulated values of ductile damage directly from the experimental values of strain at various positions over the deformed polymer sheets. The approach traces the deformation path of material elements in conical and pyramidal SPIF parts, undergoing linear strain loading paths from beginning until failure, and is built upon the generalization of the analytical framework conditions assumed by Glover et al. [1] to the pressure-sensitive yield surfaces of polymers under incompressible, non-associated, plastic flow. Experimentation in conventional and multi-stage SPIF of Polyvinylchloride (PVC sheets confirms the effectiveness of the proposed methodology and demonstrates that standard non-coupled damage models currently utilized in sheet metal forming are inapplicable to describe failure in polymers. Instead fracture forming limit lines (FFL’s should be employed.

  5. Criteria for evaluating protection from single points of failure for partially expanded fault trees

    International Nuclear Information System (INIS)

    Aswani, D.; Badreddine, B.; Malone, M.; Gauthier, G.; Proietty, J.

    2008-01-01

    Fault tree analysis (FTA) is a technique that describes the combinations of events in a system which result in an undesirable outcome. FTA is used as a tool to quantitatively assess a system's probability for an undesirable outcome. Time constraints from concept to production in modern engineering often limit the opportunity for a thorough statistical analysis of a system. Furthermore, when undesirable outcomes are considered such as hazard to human(s), it becomes difficult to identify strict statistical targets for what is acceptable. Consequently, when hazard to human(s) is concerned a common design target is to protect the system from single points of failure (SPOF) which means that no failure mode caused by a single event, concern, or error has a critical consequence on the system. Such a design target is common with 'by-wire' systems. FTA can be used to verify if a system is protected from SPOF. In this paper, sufficient criteria for evaluating protection from SPOF for partially expanded fault trees are proposed along with proof. The proposed criteria consider potential interactions between the lowest drawn events of a partial fault tree expansion which otherwise easily leads to an overly optimistic analysis of protection from SPOF. The analysis is limited to fault trees that are coherent and static

  6. Mitigation of Critical Single Point Failure (SPF) Material - Laminac 4116 Binder Replacement Program for Parachute and Cluster Stars Illuminant Compositions for Hand Held Signals

    National Research Council Canada - National Science Library

    Lakshminarayanan, G. R; Chen, Gary; Ames, Richard; Lee, Wai T; Wejsa, James L

    2006-01-01

    Laminac 4116 binder has been identified as a single point failure (SPF) material since it is being produced by only one company and there is a possibility that the company may discontinue production due to low product demand...

  7. Revisiting single-point incremental forming and formability/failure diagrams by means of finite elements and experimentation

    DEFF Research Database (Denmark)

    Silva, M. B.; Skjødt, Martin; Bay, Niels

    2009-01-01

    the forming limits determined by the analytical framework with experimental values. It is shown that agreement between analytical, finite element, and experimental results is good, implying that the previously proposed analytical framework can be utilized to explain the mechanics of deformation......In a previously published work, the current authors presented an analytical framework, built upon the combined utilization of membrane analysis and ductile damage mechanics, that is capable of modelling the fundamentals of single-point incremental forming (SPIF) of metallic sheets. The analytical...... mode of deformation. The study of the morphology of the cracks combined with the experimentally observed suppression of neck formation enabled the authors to conclude that traditional forming limit curves are inapplicable for describing failure. Instead, fracture forming limit curves should be employed...

  8. A national assessment of underground natural gas storage: identifying wells with designs likely vulnerable to a single-point-of-failure

    Science.gov (United States)

    Michanowicz, Drew R.; Buonocore, Jonathan J.; Rowland, Sebastian T.; Konschnik, Katherine E.; Goho, Shaun A.; Bernstein, Aaron S.

    2017-05-01

    The leak of processed natural gas (PNG) from October 2015 to February 2016 from the Aliso Canyon storage facility, near Los Angeles, California, was the largest single accidental release of greenhouse gases in US history. The Interagency Task Force on Natural Gas Storage Safety and California regulators recently recommended operators phase out single-point-of-failure (SPF) well designs. Here, we develop a national dataset of UGS well activity in the continental US to assess regulatory data availability and uncertainty, and to assess the prevalence of certain well design deficiencies including single-point-of-failure designs. We identified 14 138 active UGS wells associated with 317 active UGS facilities in 29 states using regulatory and company data. State-level wellbore datasets contained numerous reporting inconsistencies that limited data concatenation. We identified 2715 active UGS wells across 160 facilities that, like the failed well at Aliso Canyon, predated the storage facility, and therefore were not originally designed for gas storage. The majority (88%) of these repurposed wells are located in OH, MI, PA, NY, and WV. Repurposed wells have a median age of 74 years, and the 2694 repurposed wells constructed prior to 1979 are particularly likely to exhibit design-related deficiencies. An estimated 210 active repurposed wells were constructed before 1917—before cement zonal isolation methods were utilized. These wells are located in OH, PA, NY, and WV and represent the highest priority related to potential design deficiencies that could lead to containment loss. This national baseline assessment identifies regulatory data uncertainties, highlights a potentially widespread vulnerability of the natural gas supply chain, and can aid in prioritization and oversight for high-risk wells and facilities.

  9. Systems interaction and single failure criterion

    International Nuclear Information System (INIS)

    1983-10-01

    This study is a continued assessment of US research. All three of the systems interaction review methodologies which NRC's Systems Interaction Section (SIS) is studying are recommended. They are the Digraph-Matrix Analysis and Interactive Fault Tree/Failure Modes and Effects Analysis methodologies. A third methodology was developed for the Indian Point 3 system interaction review. It is recommended to developing the capability to perform and evaluate systems interaction reviews at Swedish nuclear plants. The Swedish demonstration studies should be performed on BWR's. (G.B.)

  10. Theory of Single Point Incremental Forming

    DEFF Research Database (Denmark)

    Martins, P.A.F.; Bay, Niels; Skjødt, Martin

    2008-01-01

    This paper presents a closed-form theoretical analysis modelling the fundamentals of single point incremental forming and explaining the experimental and numerical results available in the literature for the past couple of years. The model is based on membrane analysis with bi-directional in-plan...

  11. Systems interaction and single failure criterion

    International Nuclear Information System (INIS)

    1981-01-01

    This report documents the results of a six-month study to evaluate the ongoing research programs of the U.S. Nuclear Regulatory Commission (NRC) and U.S. commercial nuclear station owners which address the safety significance of systems interaction and the regulatory adequacy of the single failure criterion. The evaluation of system interactions provided is the initial phase of a more detailed study leading to the development and application of methodology for quantifying the relative safety of operating nuclear plants. (Auth.)

  12. Simulation of soft tissue failure using the material point method.

    Science.gov (United States)

    Ionescu, Irina; Guilkey, James E; Berzins, Martin; Kirby, Robert M; Weiss, Jeffrey A

    2006-12-01

    Understanding the factors that control the extent of tissue damage as a result of material failure in soft tissues may provide means to improve diagnosis and treatment of soft tissue injuries. The objective of this research was to develop and test a computational framework for the study of the failure of anisotropic soft tissues subjected to finite deformation. An anisotropic constitutive model incorporating strain-based failure criteria was implemented in an existing computational solid mechanics software based on the material point method (MPM), a quasi-meshless particle method for simulations in computational mechanics. The constitutive model and the strain-based failure formulations were tested using simulations of simple shear and tensile mechanical tests. The model was then applied to investigate a scenario of a penetrating injury: a low-speed projectile was released through a myocardial material slab. Sensitivity studies were performed to establish the necessary grid resolution and time-step size. Results of the simple shear and tensile test simulations demonstrated the correct implementation of the constitutive model and the influence of both fiber family and matrix failure on predictions of overall tissue failure. The slab penetration simulations produced physically realistic wound tracts, exhibiting diameter increase from entrance to exit. Simulations examining the effect of bullet initial velocity showed that the anisotropy influenced the shape and size of the exit wound more at lower velocities. Furthermore, the size and taper of the wound cavity was smaller for the higher bullet velocity. It was concluded that these effects were due to the amount of momentum transfer. The results demonstrate the feasibility of using MPM and the associated failure model for large-scale numerical simulations of soft tissue failure.

  13. Single shell tank sluicing history and failure frequency

    Energy Technology Data Exchange (ETDEWEB)

    HERTZEL, J.S.

    1998-11-10

    This document assesses the potential for failure of the single-shell tanks (SSTs) that are presumably sound and helps to establish the retrieval priorities for these and the assumed leakers. Furthermore, this report examines probabilities of SST failure as a function of age and operational history, and provides a simple statistical summary of historical leak volumes, leak rates, and corrosion factor.

  14. Improving the Patron Experience: Sterling Memorial Library's Single Service Point

    Science.gov (United States)

    Sider, Laura Galas

    2016-01-01

    This article describes the planning process and implementation of a single service point at Yale University's Sterling Memorial Library. While much recent scholarship on single service points (SSPs) has focused on the virtues or hazards of eliminating reference desks in libraries nationwide, this essay explores the ways in which single service…

  15. Transistors - From Point Contact to Single Electron

    Indian Academy of Sciences (India)

    development of the energy band theory of solids by Wilson. ... Davydov developed bis theory independently. All these theories had shortcomings as pointed out by Sab. The correct theory of metal-semiconductor diodes based on thermionic emission of majority carriers .... watches and other portable consumer applications.

  16. Application of the single failure criterion

    International Nuclear Information System (INIS)

    1990-01-01

    In order to present further details on the application and interpretation and on the limitations of individual concepts in the NUSS Codes and Safety Guides, a series of Safety Practice publications have been initiated. It is hoped that many Member States will be able to benefit from the experience presented in these books. The present publication will be useful not only to regulators but also to designers and could be particularly helpful in the interpretation of cases which fall on the borderline between the two areas. It should assist in clarifying, by way of examples, many of the concepts and implementation methods. It also describes some of the limitations involved. The book addresses a specialized topic and it is recommended that it be used together with the other books in the Safety Series. During the development of this publication the actual practices of all countries with major reactor programmes has been taken into account. An interpretation of the relevant text of the Design Code is given in the light of these national practices. The criterion is put into perspective with the general reliability requirements in which it is also embedded in the Design Code. Its relation to common cause and other multiple failure cases and also to the temporary disengagement of components in systems important to safety is clarified. Its use and its limitations are thus explained in the context of reliability targets for systems performance. The guidance provided applies to all reactor systems and would be applicable even to systems not in nuclear power plants. But since this publication was developed to give an interpretation of a specific requirement of the Design Code, the broader applicability is not explicitly claimed. The Design Code lists three cases for which compliance with the criterion may not be justified. The present publication assists in the more precise and practical identification of those cases. 9 figs, 1 tab

  17. Single and multispecies reference points for Baltic fish stocks

    DEFF Research Database (Denmark)

    Gislason, Henrik

    1999-01-01

    Single and multispecies models are used to examine the effect of species interaction on biological reference points for cod, herring, and sprat in the Baltic. The results demonstrate that reference points are different in single and multispecies contexts. Reference points for fishing mortality...... based on single-species yield and SSB calculations are difficult to use when natural mortality depends on the absolute abundance of the predators and their alternative prey. Reference points based on maximizing total yield from the system may lead to impractical results when species interact...... reference points. Management advice based on biomass reference points will also differ. In the single species situation the combinations of cod and pelagic fishing effort for which the equilibrium spawning- stock biomass of the three species is above the biomass reference points forms a rectangular area...

  18. Creating Helical Tool Paths for Single Point Incremental Forming

    DEFF Research Database (Denmark)

    Skjødt, Martin; Hancock, Michael H.; Bay, Niels

    2007-01-01

    Single point incremental forming (SPIF) is a relatively new sheet forming process. A sheet is clamped in a rig and formed incrementally using a rotating single point tool in the form of a rod with a spherical end. The process is often performed on a CNC milling machine and the tool movement...

  19. Slope failure analysis using the random material point method

    NARCIS (Netherlands)

    Wang, B.; Hicks, M.A.; Vardon, P.J.

    2016-01-01

    The random material point method (RMPM), which combines random field theory and the material point method (MPM), is proposed. It differs from the random finite-element method (RFEM), by assigning random field (cell) values to material points that are free to move relative to the computational grid

  20. Point defects and electric compensation in gallium arsenide single crystals

    International Nuclear Information System (INIS)

    Kretzer, Ulrich

    2007-01-01

    In the present thesis the point-defect budget of gallium arsenide single crystals with different dopings is studied. It is shown, in which way the concentration of the single point defects depende on the concentration of the dopants, the stoichiometry deviation, and the position of the Fermi level. For this serve the results of the measurement-technical characterization of a large number of samples, in the fabrication of which these parameters were directedly varied. The main topic of this thesis lies in the development of models, which allow a quantitative description of the experimentally studied electrical and optical properties of gallium arsenide single crystals starting from the point-defect concentrations. Because from point defects charge carriers can be set free, their concentration determines essentially the charge-carrier concentration in the bands. In the ionized state point defects act as scattering centers for free charge carriers and influence by this the drift mobility of the charge carriers. A thermodynamic modeling of the point-defect formation yields statements on the equilibrium concentrations of the point defects in dependence on dopant concentration and stoichiometry deviation. It is show that the electrical properties of the crystals observed at room temperature result from the kinetic suppression of processes, via which the adjustment of a thermodynamic equilibrium between the point defects is mediated [de

  1. Transistors-From Point Contact to Single Electron

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 2; Issue 12. Transistors – From Point Contact to Single Electron. D N Bose. General Article Volume 2 Issue 12 December 1997 pp 39-54. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/002/12/0039-0054 ...

  2. Revisiting the fundamentals of single point incremental forming by

    DEFF Research Database (Denmark)

    Silva, Beatriz; Skjødt, Martin; Martins, Paulo A.F.

    2008-01-01

    Knowledge of the physics behind the fracture of material at the transition between the inclined wall and the corner radius of the sheet is of great importance for understanding the fundamentals of single point incremental forming (SPIF). How the material fractures, what is the state of strain and...

  3. Common fixed points of single-valued and multivalued maps

    Directory of Open Access Journals (Sweden)

    Yicheng Liu

    2005-01-01

    Full Text Available We define a new property which contains the property (EA for a hybrid pair of single- and multivalued maps and give some new common fixed point theorems under hybrid contractive conditions. Our results extend previous ones. As an application, we give a partial answer to the problem raised by Singh and Mishra.

  4. Laser-induced single point nanowelding of silver nanowires

    Energy Technology Data Exchange (ETDEWEB)

    Dai, Shuowei; Li, Qiang, E-mail: qiangli@zju.edu.cn; Liu, Guoping; Yang, Hangbo; Yang, Yuanqing; Zhao, Ding; Wang, Wei; Qiu, Min, E-mail: minqiu@zju.edu.cn [State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027 (China)

    2016-03-21

    Nanowelding of nanomaterials opens up an emerging set of applications in transparent conductors, thin-film solar cells, nanocatalysis, cancer therapy, and nanoscale patterning. Single point nanowelding (SPNW) is highly demanded for building complex nanostructures. In this letter, the precise control of SPNW of silver nanowires is explored in depth, where the nanowelding is laser-induced through the plasmonic resonance enhanced photothermal effect. It is shown that the illumination position is a critical factor for the nanowelding process. As an example of performance enhancement, output at wire end can be increased by 65% after welding for a plasmonic nanocoupler. Thus, single point nanowelding technique shows great potentials for high-performance electronic and photonic devices based on nanowires, such as nanoelectronic circuits and plasmonic nanodevices.

  5. Creating Helical Tool Paths for Single Point Incremental Forming

    DEFF Research Database (Denmark)

    Skjødt, Martin; Hancock, Michael H.; Bay, Niels

    2007-01-01

    Single point incremental forming (SPIF) is a relatively new sheet forming process. A sheet is clamped in a rig and formed incrementally using a rotating single point tool in the form of a rod with a spherical end. The process is often performed on a CNC milling machine and the tool movement...... is programed using CAM software intended for surface milling. Often the function called profile milling or contour milling is applied. Using this milling function the tool only has a continuous feed rate in two directions X and Y, which is the plane of the undeformed sheet. The feed in the vertical Z direction...... from the profile milling code and converts them into a helical tool path with continuous feed in all three directions. Using the helical tool path the scarring is removed, the part is otherwise unchanged and a major disadvantage of using milling software for SPIF is removed. The solution...

  6. 3D Point Cloud Reconstruction from Single Plenoptic Image

    Directory of Open Access Journals (Sweden)

    F. Murgia

    2016-06-01

    Full Text Available Novel plenoptic cameras sample the light field crossing the main camera lens. The information available in a plenoptic image must be processed, in order to create the depth map of the scene from a single camera shot. In this paper a novel algorithm, for the reconstruction of 3D point cloud of the scene from a single plenoptic image, taken with a consumer plenoptic camera, is proposed. Experimental analysis is conducted on several test images, and results are compared with state of the art methodologies. The results are very promising, as the quality of the 3D point cloud from plenoptic image, is comparable with the quality obtained with current non-plenoptic methodologies, that necessitate more than one image.

  7. Laser-induced single point nanowelding of silver nanowires

    International Nuclear Information System (INIS)

    Dai, Shuowei; Li, Qiang; Liu, Guoping; Yang, Hangbo; Yang, Yuanqing; Zhao, Ding; Wang, Wei; Qiu, Min

    2016-01-01

    Nanowelding of nanomaterials opens up an emerging set of applications in transparent conductors, thin-film solar cells, nanocatalysis, cancer therapy, and nanoscale patterning. Single point nanowelding (SPNW) is highly demanded for building complex nanostructures. In this letter, the precise control of SPNW of silver nanowires is explored in depth, where the nanowelding is laser-induced through the plasmonic resonance enhanced photothermal effect. It is shown that the illumination position is a critical factor for the nanowelding process. As an example of performance enhancement, output at wire end can be increased by 65% after welding for a plasmonic nanocoupler. Thus, single point nanowelding technique shows great potentials for high-performance electronic and photonic devices based on nanowires, such as nanoelectronic circuits and plasmonic nanodevices.

  8. SAFETY ALERT - Failure of brass non-return valves in gas point installations

    CERN Multimedia

    HSE Unit

    2016-01-01

    There have been three recent failures in brass non-return valves in separate high pressure gas point installations across CERN. Whilst each was in a different gas service, the visual nature of the failure has been similar.   In all three cases, these components were connected to stainless steel flexible connections and stainless steel pipework. From the metallurgical investigation of the failed component, it appears that the failure is linked to uncontrolled tightening, leading to a localised weakening resulting in premature failure when subjected to pressure. Lead levels in the examined components appear to be a contributing factor to the reduction in ductility but are not identified as the root cause. It has also not been possible to attribute failure to a particular batch of material. The Occupational Health & Safety and Environmental Protection Unit prescribes the following actions to be taken, aligned with the CERN Safety Rules: Verification of all brass non-return valves (prioritising...

  9. ODMR of single point defects in silicon nanostructures

    Energy Technology Data Exchange (ETDEWEB)

    Bagraev, Nikolay; Danilovsky, Eduard; Gets, Dmitry; Klyachkin, Leonid; Kudryavtsev, Andrey; Kuzmin, Roman; Malyarenko, Anna [Ioffe Physical-Technical Institute, Polytekhnicheskaya st. 26, 194021 St. Petersburg (Russian Federation)

    2012-05-15

    We present the findings of the optically detected magnetic resonance technique (ODMR), which reveal single point defects in the ultra-narrow silicon quantum wells (Si-QW) confined by the superconductor {delta}-barriers. This technique allows the ODMR identification without application of an external cavity, as well as a high frequency source and recorder, and with measuring the transmission spectra within the frameworks of the excitonic normal-mode coupling caused by the microcavities embedded in the Si-QW plane. (copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  10. Geometry of single-point turning tools and drills

    CERN Document Server

    Astakhov, Viktor P

    2010-01-01

    Tools for metal cutting have many shapes and features, each of which is described by its angles or geometries. The selection of the right cutting tool geometry is critical because it directly affects the integrity of the machined surface, tool life, power needed for machining, and thus the overall machining efficiency. ""Geometry of Single-Point Turning Tools and Drills"" outlines clear objectives of cutting tool geometry selection and optimization, using multiple examples to provide a thorough explanation. The establishment of clear bridges between cutting theory, tool geometry, and shop prac

  11. Testing single point incremental forming molds for thermoforming operations

    Science.gov (United States)

    Afonso, Daniel; de Sousa, Ricardo Alves; Torcato, Ricardo

    2016-10-01

    Low pressure polymer processing processes as thermoforming or rotational molding use much simpler molds then high pressure processes like injection. However, despite the low forces involved with the process, molds manufacturing for this operations is still a very material, energy and time consuming operation. The goal of the research is to develop and validate a method for manufacturing plastically formed sheets metal molds by single point incremental forming (SPIF) operation for thermoforming operation. Stewart platform based SPIF machines allow the forming of thick metal sheets, granting the required structural stiffness for the mold surface, and keeping the short lead time manufacture and low thermal inertia.

  12. Point defects in electron-irradiated oxide single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Caulfield, K.J.; Cooper, R. [Univ. of Melbourne, Parkville, Victoria (Australia). Dept. of Chemistry; Boas, J.F. [Australian Radiation Lab., Yallambie, Victoria (Australia)

    1995-04-01

    Point defects have been produced in CaO, MgO, and {alpha}-Al{sub 2}O{sub 3} single crystals by electron irradiation, and thresholds for atomic displacement have been measured using time-resolved luminescence spectroscopy. Oxygen displacement energies of approximately 50 eV have been determined; however, a temperature-dependent threshold observed for an emission band in MgO may arise from a magnesium displacement. A 300-nm emission in {alpha}-Al{sub 2}O{sub 3} may be due to an F-center transition. Studies of radiative recombination kinetics are consistent with an electron-detrapping model.

  13. Slope failure with the material point method : An investigation of post-peak material behaviour

    NARCIS (Netherlands)

    Vardon, P.J.; Wang, B.; Hicks, M.A.

    2017-01-01

    The material point method (MPM) has the potential to simulate the onset, the full evolution and the final condition of a slope failure. It is a variant of the finite element method (FEM), where the material is able to move through the mesh, thereby solving one of the major problems in FEM of mesh

  14. Securing Single Points of Compromise (SPoC)

    Energy Technology Data Exchange (ETDEWEB)

    Belangia, David Warren [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-06-25

    Securing the Single Points of Compromise that provide central services to the institution’s environment is paramount to success when trying to protect the business. (Fisk, 2014) Time Based Security mandates protection (erecting and ensuring effective controls) that last longer than the time to detect and react to a compromise. When enterprise protections fail, providing additional layered controls for these central services provides more time to detect and react. While guidance is readily available for securing the individual critical asset, protecting these assets as a group is not often discussed. Using best business practices to protect these resources as individual assets while leveraging holistic defenses for the group increases the opportunity to maximize protection time, allowing detection and reaction time for the SPoCs that is commensurate with the inherent risk of these centralized services.

  15. The Analysis of Forming Forces in Single Point Incremental Forming

    Directory of Open Access Journals (Sweden)

    Koh Kyung Hee

    2016-01-01

    Full Text Available Incremental forming is a process to produce sheet metal parts in quick. Because there is no need for dedicated dies and molds, this process is less cost and time spent. The purpose of this study is to investigate forming forces in single point incremental forming. Producing a cone frustum of aluminum is tested for forming forces. A dynamometer is used to collect forming forces and analyze them. These forces are compared with cutting forces upon producing same geometrical shapes of experimental parts. The forming forces in Z direction are 40 times larger than the machining forces. A spindle and its axis of a forming machine should be designed enough to withstand the forming forces.

  16. Code Single Point Positioning Using Nominal GNSS Constellations (Future Perception)

    Science.gov (United States)

    Farah, A. M. A.

    Global Navigation Satellite Systems (GNSS) have an endless number of applications in industry, science, military, transportation and recreation & sports. Two systems are currently in operation, namely GPS (the USA Global Positioning System) and GLONASS (the Russian GLObal NAvigation Satellite System), and a third is planned, the European satellite navigation system GALILEO. The potential performance improvements achievable through combining these systems could be significant and expectations are high. The need is inevitable to explore the future of positioning from different nominal constellations. In this research paper, Bernese 5.0 software could be modified to simulate and process GNSS observations from three different constellations (GPS, GLONASS and Galileo) using different combinations. This study presents results of code single point positioning for five stations using the three constellations and different combinations.

  17. Single Point Incremental Forming using a Dummy Sheet

    DEFF Research Database (Denmark)

    Skjødt, Martin; Silva, Beatriz; Bay, Niels

    2007-01-01

    A new version of single point incremental forming (SPIF) is presented. This version includes a dummy sheet on top of the work piece, thus forming two sheets instead of one. The dummy sheet, which is in contact with the rotating tool pin, is discarded after forming. The new set-up influences...... the process and furthermore offers a number of new possibilities for solving some of the problems appearing in SPIF. Investigations of the influence of dummy sheet on: formability, wear, surface quality and bulging of planar sides is done by forming to test shapes: a hyperboloid and a truncated pyramid....... The possible influence of friction between the two sheets is furthermore investigated. The results show that the use of a dummy sheet reduces wear of the work piece to almost zero, but also causes a decrease in formability. Bulging of the planar sides of the pyramid is reduced and surface roughness...

  18. Single supplier single retailer inventory model controlled by the reorder and shipping points with sharing information

    Science.gov (United States)

    Ho, Wen-Tsung; Hsiao, Yu-Cheng

    2012-04-01

    This study investigated the integrated stochastic inventory problem for a two-stage supply chain consisting of a single retailer and a single supplier. By using batch shipment policy, the expected total cost can be significantly reduced. An equally sized batch shipment model, controlled by both the reorder and shipping points, with sharing information by enterprise resource planning and radio frequency identification is constructed. The problem is solved optimally by the proposed algorithm that determines the economic lot size, the optimal batch sizes and number of batches. A numerical example is included to illustrate the algorithmic procedures and to prove that the model controlled both by the reorder and shipping points is superior to the classic model controlled only by the reorder point.

  19. Failure analysis of high strength pipeline with single and multiple corrosions

    International Nuclear Information System (INIS)

    Chen, Yanfei; Zhang, Hong; Zhang, Juan; Li, Xin; Zhou, Jing

    2015-01-01

    Highlights: • We study failure of high strength pipelines with single corrosion. • We give regression equations for failure pressure prediction. • We propose assessment procedure for pipelines with multiple corrosions. - Abstract: Corrosion will compromise safety operation of oil and gas pipelines, accurate determination of failure pressure finds importance in residual strength assessment and corrosion allowance design of onshore and offshore pipelines. This paper investigates failure pressure of high strength pipeline with single and multiple corrosions using nonlinear finite element analysis. On the basis of developed regression equations for failure pressure prediction of high strength pipeline with single corrosion, the paper proposes an assessment procedure for predicting failure pressure of high strength pipeline with multiple corrosions. Furthermore, failure pressures predicted by proposed solutions are compared with experimental results and various assessment methods available in literature, where accuracy and versatility are demonstrated

  20. Malaria induced acute renal failure: A single center experience

    International Nuclear Information System (INIS)

    KV Kanodia; AV Vanikar

    2010-01-01

    Malaria has protean clinical manifestations and renal complications, particularly acute renal failure that could be life threatening. To evaluate the incidence, clinical profile, ou come and predictors of mortality in patients with malarial acute renal failure, we retrospectively studied the last two years records of malaria induced acute renal failure in patients with peripheral smear positive for malarial parasites. One hundred (10.4%) (63 males, 37 females) malaria induced acute renal failure amongst 958 cases of acute renal failure were evaluated. Plasmodium (P). falciparum was reported in 85%, P. vivax in 2%, and both in 13% patients. The mean serum creatinine was 9.2 ± 4.2 mg%, and oligo/anuria was present in 82%; 78% of the patients required hemodialysis. Sixty four percent of the patients recovered completely, 10% incompletely, and 5% developed chronic kidney failure; mortality occurred in 21% of the patients. Low hemoglobin, oligo/anuria on admission, hyperbilirubinemia, cerebral malaria, disseminated intravascular coagulation, and high serum creatinine were the main predictors of mortality. We conclude that malaria is associated with acute renal failure, which occurs most commonly in plasmodium falciparum infected patients. Early diagnosis and prompt dialysis with supportive management can reduce morality and enhance recovery of renal function (Author).

  1. Sodium Channel β2 Subunits Prevent Action Potential Propagation Failures at Axonal Branch Points.

    Science.gov (United States)

    Cho, In Ha; Panzera, Lauren C; Chin, Morven; Hoppa, Michael B

    2017-09-27

    Neurotransmitter release depends on voltage-gated Na + channels (Na v s) to propagate an action potential (AP) successfully from the axon hillock to a synaptic terminal. Unmyelinated sections of axon are very diverse structures encompassing branch points and numerous presynaptic terminals with undefined molecular partners of Na + channels. Using optical recordings of Ca 2+ and membrane voltage, we demonstrate here that Na + channel β2 subunits (Na v β2s) are required to prevent AP propagation failures across the axonal arborization of cultured rat hippocampal neurons (mixed male and female). When Na v β2 expression was reduced, we identified two specific phenotypes: (1) membrane excitability and AP-evoked Ca 2+ entry were impaired at synapses and (2) AP propagation was severely compromised with >40% of axonal branches no longer responding to AP-stimulation. We went on to show that a great deal of electrical signaling heterogeneity exists in AP waveforms across the axonal arborization independent of axon morphology. Therefore, Na v β2 is a critical regulator of axonal excitability and synaptic function in unmyelinated axons. SIGNIFICANCE STATEMENT Voltage-gated Ca 2+ channels are fulcrums of neurotransmission that convert electrical inputs into chemical outputs in the form of vesicle fusion at synaptic terminals. However, the role of the electrical signal, the presynaptic action potential (AP), in modulating synaptic transmission is less clear. What is the fidelity of a propagating AP waveform in the axon and what molecules shape it throughout the axonal arborization? Our work identifies several new features of AP propagation in unmyelinated axons: (1) branches of a single axonal arborization have variable AP waveforms independent of morphology, (2) Na + channel β2 subunits modulate AP-evoked Ca 2+ -influx, and (3) β2 subunits maintain successful AP propagation across the axonal arbor. These findings are relevant to understanding the flow of excitation in the

  2. Management of early Fontan failure: a single-institution experience.

    Science.gov (United States)

    Murphy, Michael O; Glatz, Andrew C; Goldberg, David J; Rogers, Lindsay S; Ravishankar, Chitra; Nicolson, Susan C; Steven, James M; Fuller, Stephanie; Spray, Thomas L; Gaynor, J William

    2014-09-01

    To analyse the incidence and outcomes of early Fontan failure (EFF) in a large contemporary cohort of palliated patients. A retrospective, single-centre study of all patients undergoing primary Fontan from 1 July 1995 to 31 December 2009 was performed. EFF was defined as death, need for extracorporeal membrane oxygenation (ECMO), Fontan takedown to superior cavopulmonary connection (SCPC) or transplantation within 30 days of the Fontan procedure. The incidence and outcomes were summarized with descriptive statistics, and risk factors for EFF were identified. A total of 592 patients underwent primary Fontan procedure during the study period; 67% had a dominant right ventricle. An extracardiac conduit (ECC) was used for Fontan completion in 60.5%, with the remainder having a lateral tunnel. EFF occurred in 11 patients (1.9%), all of whom had ECC. ECMO was used in 5 patients, 5 had Fontan takedown and 2 had heart transplantation. Five of eleven, or 46%, study subjects died as opposed to an overall mortality for primary Fontan of 0.8%. Among patients who had Fontan takedown to SCPC, long-term survival was 80%. By univariate analysis, elevated ventricular end-diastolic pressure (9.5 ± 3.3 vs 7.4 ± 2.7 mmHg, P = 0.019) and total circulatory support time (99 ± 33 vs 71 ± 23 min, P = 0.001) were risk factors for EFF. The mean follow-up for the 6 hospital survivors was 5.9 years. There was one late transplant-related death. Of the 4 surviving patients who had Fontan takedown to a SCPC, 3 underwent subsequent Fontan completion and 1 underwent biventricular repair. EFF is rare in the current era, but is associated with significant mortality. High filling pressures and a prolonged intraoperative course are risk factors for EFF. Of the management strategies available, Fontan takedown to an intermediate pathway appears to be associated with the best outcomes. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio

  3. A Failure Criterion for Single-Walled Carbon Nanotubes Based on Molecular Mechanics

    Science.gov (United States)

    Avila, Antonio; Lacerda, Guilherme

    2008-03-01

    Single-walled carbon nanotubes (SWNT) are the natural choice for high performance materials. The problem, however, rises when the experimental data are compared against each other. The large variability of experimental data lead to development of a new set of numerical simulations called molecular mechanics, which is a ``symbiotic'' association of molecular dynamics and solid mechanics. This papers deals with a molecular mechanics simulations of single-walled carbon nanotubes. Three SWNT configurations and its combinations were simulated, i.e. armchair, zigzag and chiral. The failure criterion introduced is based on modified Morse's potential with dissociation energy of 124 Kcal/mol and an inflection point considered is around 13% of strain. The numerical data are in good agreement with data from Belytschko et al. (2002) where the failure occurred at 10.6% strain at 65.2 GPa of stress. To be able to identify the highest stress concentration region, one end of the SWNT all degrees-of-freedom were fixed and a prescribed axial displacement was applied at the opposite end. The Sadoc (chiral-chiral) configuration had the highest stress at the smallest chiral SWNT. For the Dunlap configuration (chiral-zigzag) the highest stress occurred at chiral part close to the pentagon location.

  4. Single-frequency, single-receiver terrestrial and spaceborne point positioning

    Science.gov (United States)

    Beran, Tomas

    High-accuracy, point positioning has been an attractive research topic in the GPS community for a number of years. The overall quality of precise point positioning results is also dependent on the quality of the GPS measurements and the user's processing software. Dual-frequency, geodetic-quality GPS receivers are routinely used both in static and kinematic applications for high-accuracy point positioning. However, use of low-cost, single-frequency GPS receivers in similar applications creates a challenge because of difficulty of handling the ionosphere, multipath and other measurement error sources. Potential use of such receivers to provide horizontal positioning accuracies of a few decimetres, and vertical accuracies of less than two metres, will be examined in this dissertation. Practical applications of post-processed, high-accuracy, single-frequency point positioning include a myriad of terrestrial and space-borne applications, where the size and cost of the GPS unit is an issue. The processing technique uses pseudorange and time-differenced carrier-phase measurements in a sequential least-squares filter. In developing the approach, different techniques were investigated. Ionospheric delay grid maps are used to remove the bulk of the ionospheric error, while tropospheric error is handled by a prediction model. Pseudorange multipath errors are mitigated by means of stochastic modelling and carrier-phase cycle slips are detected and corrupted measurements are removed in a quality-control algorithm. The technique was first tested on L1 measurements extracted from datasets from static, high-quality GPS receivers. Accuracies better than two-decimetres in horizontal components (northing and easting r.m.s.), and three-decimetre accuracies in the vertical component (up-component r.m.s.), were obtained. A test dataset from a stationary low-cost GPS receiver has been processed to demonstrate the difference in data quality. Positioning results obtained are worse than

  5. Reliability modelling for wear out failure period of a single unit system

    OpenAIRE

    Arekar, Kirti; Ailawadi, Satish; Jain, Rinku

    2012-01-01

    The present paper deals with two time-shifted density models for wear out failure period of a single unit system. The study, considered the time-shifted Gamma and Normal distributions. Wear out failures occur as a result of deterioration processes or mechanical wear and its probability of occurrence increases with time. A failure rate as a function of time deceases in an early failure period and it increases in wear out period. Failure rates for time shifted distributions and expression for m...

  6. A Numerical Investigation of CFRP-Steel Interfacial Failure with Material Point Method

    International Nuclear Information System (INIS)

    Shen Luming; Faleh, Haydar; Al-Mahaidi, Riadh

    2010-01-01

    The success of retrofitting steel structures by using the Carbon Fibre Reinforced Polymers (CFRP) significantly depends on the performance and integrity of CFRP-steel joint and the effectiveness of the adhesive used. Many of the previous numerical studies focused on the design and structural performance of the CFRP-steel system and neglected the mechanical responses of adhesive layer, which results in the lack of understanding in how the adhesive layer between the CFRP and steel performs during the loading and failure stages. Based on the recent observation on the failure of CFRP-steel bond in the double lap shear tests, a numerical approach is proposed in this study to simulate the delamination process of CFRP sheet from steel plate using the Material Point Method (MPM). In the proposed approach, an elastoplasticity model with a linear hardening and softening law is used to model the epoxy layer. The MPM, which does not employ fixed mesh-connectivity, is employed as a robust spatial discretization method to accommodate the multi-scale discontinuities involved in the CFRP-steel bond failure process. To demonstrate the potential of the proposed approach, a parametric study is conducted to investigate the effects of bond length and loading rates on the capacity and failure modes of CFRP-steel system. The evolution of the CFRP-steel bond failure and the distribution of stress and strain along bond length direction will be presented. The simulation results not only well match the available experimental data but also provide a better understanding on the physics behind the CFRP sheet delamination process.

  7. State-of-health monitoring of 18650 4S packs with a single-point impedance diagnostic

    Science.gov (United States)

    Love, Corey T.; Virji, Maheboob B. V.; Rocheleau, Richard E.; Swider-Lyons, Karen E.

    2014-11-01

    The state-of-health (SOH) of Li-ion batteries and battery packs must be monitored effectively for abuse to prevent failure and accidents. In a previous publication, we described a single-point impedance diagnostic method for detecting damage in single prismatic lithium polymer rechargeable cells subjected to overcharge abuse. We now determine whether the single-point impedance diagnostic method is applicable to 4S battery packs. At 316 Hz, commercial 18650 LiCoO2 cells are determined to have the least change in impedance response when cycled between 3.0 and 4.2 V, for states-of-charge (SOC) of 0-100%. The impedance response of single cells at 316 Hz changes dramatically during overcharge (SOC = 125%), presumably due to change in their solid electrolyte interface (SEI) layers at the electrodes. When a single cell is purposely subjected to such overcharge abuse and then integrated into a 4S pack with 3 other healthy cells, the impedance response of the 4S pack at 316 Hz also changes, despite variances in the impedance response of each of the 3 healthy cells. The results suggest that this single-point impedance method could serve as a diagnostic in an all-inclusive battery management system to identify overcharge abuse of single cells without individual cell monitoring.

  8. Early complications and short-term failures of zirconia single crowns and partial fixed dental prostheses.

    Science.gov (United States)

    Pihlaja, Juha; Näpänkangas, Ritva; Raustia, Aune

    2014-10-01

    Ceramic single crowns fabricated from newer materials, especially zirconia, have shown relatively high survival rates. However, early reversible complications may increase the risk of an irreversible failure later. The purpose of the study was to evaluate the early complications and short-term failures of zirconia single crowns and partial fixed dental prostheses (FDPs) made by predoctoral dental students. Data were collected from the patient records. Altogether, 264 zirconia single crowns and 120 FDPs (342 abutments and 190 pontics) were fabricated for 173 patients between 2007 and 2010. Early complications were recorded during the prosthetic treatment phase, and short-term failures were recorded during the first year in use. The most frequent early complications were localized gingival irritation (1.9% of single crowns and 2.5% of FDP) and postoperative tooth sensitivity (0.4% of single crowns and 3.3% of FDPs). Pulp exposure during preparation was recorded in 3 abutment teeth of the FDPs. The most frequent short-term failure was chipping of the veneering porcelain (0.8% for single crowns, 0.8% for FDPs). One crown lost cementation because of poor retention (0.4%), and 2 FDPs failed because of framework fractures (1.7%). The most frequent early complications were localized gingival irritation and postoperative tooth sensitivity, and the most frequent short-term failure was chipping of the veneering porcelain. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Fuel-element failures in Hanford single-pass reactors 1944--1971

    Energy Technology Data Exchange (ETDEWEB)

    Gydesen, S.P.

    1993-07-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions since 1944 from the US Department of Energy`s (DOE) Hanford Site near Richland, Washington. To estimate the doses, the staff of the Source Terms Task use operating information from historical documents to approximate the radioactive emissions. One source of radioactive emissions to the Columbia River came from leaks in the aluminum cladding of the uranium metal fuel elements in single-pass reactors. The purpose of this letter report is to provide photocopies of the documents that recorded these failures. The data from these documents will be used by the Source Terms Task to determine the contribution of single-pass reactor fuel-element failures to the radioactivity of the reactor effluent from 1944 through 1971. Each referenced fuel-element failure occurring in the Hanford single-pass reactors is addressed. The first recorded failure was in 1948, the last in 1970. No records of fuel-element failures were found in documents prior to 1948. Data on the approximately 2000 failures which occurred during the 28 years (1944--1971) of Hanford single-pass reactor operations are provided in this report.

  10. Fuel-element failures in Hanford single-pass reactors 1944--1971

    International Nuclear Information System (INIS)

    Gydesen, S.P.

    1993-07-01

    The primary objective of the Hanford Environmental Dose Reconstruction (HEDR) Project is to estimate the radiation dose that individuals could have received as a result of emissions since 1944 from the US Department of Energy's (DOE) Hanford Site near Richland, Washington. To estimate the doses, the staff of the Source Terms Task use operating information from historical documents to approximate the radioactive emissions. One source of radioactive emissions to the Columbia River came from leaks in the aluminum cladding of the uranium metal fuel elements in single-pass reactors. The purpose of this letter report is to provide photocopies of the documents that recorded these failures. The data from these documents will be used by the Source Terms Task to determine the contribution of single-pass reactor fuel-element failures to the radioactivity of the reactor effluent from 1944 through 1971. Each referenced fuel-element failure occurring in the Hanford single-pass reactors is addressed. The first recorded failure was in 1948, the last in 1970. No records of fuel-element failures were found in documents prior to 1948. Data on the approximately 2000 failures which occurred during the 28 years (1944--1971) of Hanford single-pass reactor operations are provided in this report

  11. Risk factors for failure of a single surgical debridement in adults with acute septic arthritis.

    Science.gov (United States)

    Hunter, Joshua G; Gross, Jonathan M; Dahl, Jason D; Amsdell, Simon L; Gorczyca, John T

    2015-04-01

    Acute septic arthritis in a native joint may require more than one surgical debridement to eradicate the infection. Our objectives were to determine the prevalence of failure of a single surgical debridement for acute septic arthritis, to identify risk factors for failure of a single debridement, and to develop a prognostic probability algorithm to predict failure of a single surgical debridement for acute septic arthritis in adults. We collected initial laboratory and medical comorbidity data of 128 adults (132 native joints) with acute septic arthritis who underwent at least one surgical debridement at our institution between 2000 and 2011. Univariate and logistic regression analyses were used to identify potential risk factors for failure of a single surgical debridement. Stepwise variable selection was used to develop a prediction model and identify probabilities of failure of a single surgical debridement. Of the 128 patients (132 affected joints) who underwent surgical debridement for acute septic arthritis, forty-nine (38%) of the patients (fifty joints) experienced failure of a single debridement and required at least two debridements (range, two to four debridements). Staphylococcus aureus was the most common bacterial isolate (in sixty, or 45%, of the 132 joints). Logistic regression analysis identified five independent clinical predictors for failure of a single surgical debridement: a history of inflammatory arthropathy (odds ratio [OR], 7.3; 95% confidence interval [CI], 2.4 to 22.6; p 85.0 x 10(9) cells/L (OR, 4.7; 95% CI, 1.8 to 17.7; p = 0.002), S. aureus as the bacterial isolate (OR, 4.6; 95% CI, 1.8 to 11.9; p = 0.002), and a history of diabetes (OR, 2.6; 95% CI, 1.1 to 6.2; p = 0.04). Most (62%) of the septic joints were managed effectively with a single surgical debridement. Adults with a history of inflammatory arthropathy, involvement of a large joint, a synovial-fluid nucleated cell count of >85.0 x 10(9) cells/L, an infection with S. aureus

  12. Comparing Single-Point and Multi-point Calibration Methods in Modulated DSC

    Energy Technology Data Exchange (ETDEWEB)

    Van Buskirk, Caleb Griffith [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-14

    Heat capacity measurements for High Density Polyethylene (HDPE) and Ultra-high Molecular Weight Polyethylene (UHMWPE) were performed using Modulated Differential Scanning Calorimetry (mDSC) over a wide temperature range, -70 to 115 °C, with a TA Instruments Q2000 mDSC. The default calibration method for this instrument involves measuring the heat capacity of a sapphire standard at a single temperature near the middle of the temperature range of interest. However, this method often fails for temperature ranges that exceed a 50 °C interval, likely because of drift or non-linearity in the instrument's heat capacity readings over time or over the temperature range. Therefore, in this study a method was developed to calibrate the instrument using multiple temperatures and the same sapphire standard.

  13. Failure Rate of Single Dose Methotrexate in Managment of Ectopic Pregnancy

    Directory of Open Access Journals (Sweden)

    Feras Sendy

    2015-01-01

    Full Text Available Background. One of the treatment modalities for ectopic pregnancy is methotrexate. The purpose of this study is to identify the failure rate of methotrexate in treating patients with ectopic pregnancy as well as the risk factors leading to treatment failure. Methods. A retrospective chart review of 225 patients who received methotrexate as a primary management option for ectopic pregnancy. Failure of single dose of methotrexate was defined as drop of BHCG level less than or equal to 14% in the seventh day after administration of methotrexate. Results. 225 patients had methotrexate. Most of the patients (151 (67% received methotrexate based on the following formula: f 50 mg X body surface area. Single dose of methotrexate was successful in 72% (162/225 of the patients. 28% (63/225 were labeled as failure of single dose of methotrexate because of suboptimal drop in BhCG. 63% (40/63 of failure received a second dose of methotrexate, and 37% (23/63 underwent surgical treatment. Among patient who received initial dose of methotrexate, 71% had moderate or severe pain, and 58% had ectopic mass size of more than 4 cm on ultrasound. Conclusion. Liberal use of medical treatment of ectopic pregnancy results in 71% success rate.

  14. Strength and Failure Mechanism of Composite-Steel Adhesive Bond Single Lap Joints

    Directory of Open Access Journals (Sweden)

    Kai Wei

    2018-01-01

    Full Text Available Carbon fiber-reinforced plastics- (CFRP- steel single lap joints with regard to tensile loading with two levels of adhesives and four levels of overlap lengths were experimentally analyzed and numerically simulated. Both joint strength and failure mechanism were found to be highly dependent on adhesive type and overlap length. Joints with 7779 structural adhesive were more ductile and produced about 2-3 kN higher failure load than MA830 structural adhesive. Failure load with the two adhesives increased about 147 N and 176 N, respectively, with increasing 1 mm of the overlap length. Cohesion failure was observed in both types of adhesive joints. As the overlap length increased, interface failure appeared solely on the edge of the overlap in 7779 adhesive joints. Finite element analysis (FEA results revealed that peel and shear stress distributions were nonuniform, which were less severe as overlap length increased. Severe stress concentration was observed on the overlap edge, and shear failure of the adhesive was the main reason for the adhesive failure.

  15. Responsiveness of Myofascial Trigger Points to Single and Multiple Trigger Point Release Massages: A Randomized, Placebo Controlled Trial.

    Science.gov (United States)

    Moraska, Albert F; Schmiege, Sarah J; Mann, John D; Butryn, Nathan; Krutsch, Jason P

    2017-09-01

    This study aimed to assess the effects of single and multiple massage treatments on pressure-pain threshold (PPT) at myofascial trigger points (MTrPs) in people with myofascial pain syndrome expressed as tension-type headache. Individuals (n = 62) with episodic or chronic tension-type headache were randomized to receive 12 twice-weekly 45-min massage or sham ultrasound sessions or wait-list control. Massage focused on trigger point release (ischemic compression) of MTrPs in the bilateral upper trapezius and suboccipital muscles. PPT was measured at MTrPs with a pressure algometer pre and post the first and final (12th) treatments. PPT increased across the study timeframe in all four muscle sites tested for massage, but not sham ultrasound or wait-list groups (P trigger points to myofascial pain; (2) Describe an effective treatment for decreasing tenderness of a myofascial trigger point; and (3) Discuss the relative values of single vs. multiple massage sessions on increasing pressure-pain thresholds at myofascial trigger points. Advanced ACCREDITATION: The Association of Academic Physiatrists is accredited by the Accreditation Council for Continuing Medical Education to provide continuing medical education for physicians.The Association of Academic Physiatrists designates this Journal-based CME activity for a maximum of 0.5 AMA PRA Category 1 Credit(s)™. Physicians should only claim credit commensurate with the extent of their participation in the activity.

  16. Enhancing network performance under single link failure with AS-disjoint BGP extension

    DEFF Research Database (Denmark)

    Manolova, Anna Vasileva; Romeral, S.; Ruepp, Sarah Renée

    2009-01-01

    In this paper we propose an enhancement of the BGP protocol for obtaining AS-disjoint paths in GMPLS multi-domain networks. We evaluate the benefits of having AS-disjoint paths under single inter-domain link failure for two main applications: routing of future connection requests during routing...... protocol re-convergence and applying multi-domain restoration as survivability mechanism in case of a single link failure. The proposed BGP modification is a simple and effective solution for disjoint path selection in connection-oriented multi-domain networks. Our results show that applying the proper...... failure notification method combined with our proposal reduces the blocking of new connection requests under protocol re-convergence. Furthermore. we show that our proposal is a valuable complementary process for increasing the network resilience....

  17. Acute Respiratory Failure in Renal Transplant Recipients: A Single Intensive Care Unit Experience.

    Science.gov (United States)

    Ulas, Aydin; Kaplan, Serife; Zeyneloglu, Pinar; Torgay, Adnan; Pirat, Arash; Haberal, Mehmet

    2015-11-01

    Frequency of pulmonary complications after renal transplant has been reported to range from 3% to 17%. The objective of this study was to evaluate renal transplant recipients admitted to an intensive care unit to identify incidence and cause of acute respiratory failure in the postoperative period and compare clinical features and outcomes between those with and without acute respiratory failure. We retrospectively screened the data of 540 consecutive adult renal transplant recipients who received their grafts at a single transplant center and included those patients admitted to an intensive care unit during this period for this study. Acute respiratory failure was defined as severe dyspnea, respiratory distress, decreased oxygen saturation, hypoxemia or hypercapnia on room air, or requirement of noninvasive or invasive mechanical ventilation. Among the 540 adult renal transplant recipients, 55 (10.7%) were admitted to an intensive care unit, including 26 (47.3%) admitted for acute respiratory failure. Median time from transplant to intensive care unit admission was 10 months (range, 0-67 mo). The leading causes of acute respiratory failure were bacterial pneumonia (56%) and cardiogenic pulmonary edema (44%). Mean partial pressure of arterial oxygen to fractional inspired oxygen ratio was 174 ± 59, invasive mechanical ventilation was used in 13 patients (50%), and noninvasive mechanical ventilation was used in 8 patients (31%). The overall mortality was 16.4%. Acute respiratory failure was the reason for intensive care unit admission in almost half of our renal transplant recipients. Main causes of acute respiratory failure were bacterial pneumonia and cardiogenic pulmonary edema. Mortality of patients admitted for acute respiratory failure was similar to those without acute respiratory failure.

  18. Comparison of Single-Point and Continuous Sampling Methods for Estimating Residential Indoor Temperature and Humidity.

    Science.gov (United States)

    Johnston, James D; Magnusson, Brianna M; Eggett, Dennis; Collingwood, Scott C; Bernhardt, Scott A

    2015-01-01

    Residential temperature and humidity are associated with multiple health effects. Studies commonly use single-point measures to estimate indoor temperature and humidity exposures, but there is little evidence to support this sampling strategy. This study evaluated the relationship between single-point and continuous monitoring of air temperature, apparent temperature, relative humidity, and absolute humidity over four exposure intervals (5-min, 30-min, 24-hr, and 12-days) in 9 northern Utah homes, from March-June 2012. Three homes were sampled twice, for a total of 12 observation periods. Continuous data-logged sampling was conducted in homes for 2-3 wks, and simultaneous single-point measures (n = 114) were collected using handheld thermo-hygrometers. Time-centered single-point measures were moderately correlated with short-term (30-min) data logger mean air temperature (r = 0.76, β = 0.74), apparent temperature (r = 0.79, β = 0.79), relative humidity (r = 0.70, β = 0.63), and absolute humidity (r = 0.80, β = 0.80). Data logger 12-day means were also moderately correlated with single-point air temperature (r = 0.64, β = 0.43) and apparent temperature (r = 0.64, β = 0.44), but were weakly correlated with single-point relative humidity (r = 0.53, β = 0.35) and absolute humidity (r = 0.52, β = 0.39). Of the single-point RH measures, 59 (51.8%) deviated more than ±5%, 21 (18.4%) deviated more than ±10%, and 6 (5.3%) deviated more than ±15% from data logger 12-day means. Where continuous indoor monitoring is not feasible, single-point sampling strategies should include multiple measures collected at prescribed time points based on local conditions.

  19. Single Point Adjustments: A New Definition with Examples. Acquisition Review Quarterly, Fall 2001

    National Research Council Canada - National Science Library

    Bachman, David

    2002-01-01

    .... A single point adjustment (SPA) is made when a contract's existing cost and/or schedule variances are set to zero and all the remaining work is replanned with the goal of completing the project on schedule and on budget...

  20. Restorability on 3-connected WDM Networks Under Single and Dual Physical Link Failures

    DEFF Research Database (Denmark)

    Gutierrez Lopez, Jose Manuel; Jensen, Michael; Riaz, Tahir

    2013-01-01

    This work studies the influence the network interconnection has over restoration techniques. The way physical links are distributed to interconnect network nodes has a great impact on parameters such as path distances when failures occur and restoration is applied. The work focuses on single and ...... to network planning, the trade-off network length vs. performance of the different topological options is studied. The results show how 3-connected graphs could provide a reasonable trade-off between costs, link failure rates, and restored path parameters....

  1. SEE Transient Response of Crane Interpoint Single Output Point of Load DC-DC Converters

    Science.gov (United States)

    Sanders, Anthony B.; Chen, Dakai; Kim, Hak S.; Phan, Anthony M.

    2011-01-01

    This study was undertaken to determine the single event effect and transient susceptibility of the Crane Interpoint Maximum Flexible Power (MFP) Single Output Point of Load DC/DC Converters for transient interruptions in the output signal and for destructive and non destructive events induced by exposing it to a heavy ion beam..

  2. Point Estimation Method of Electromagnetic Flowmeters Life Based on Randomly Censored Failure Data

    Directory of Open Access Journals (Sweden)

    Zhen Zhou

    2014-08-01

    Full Text Available This paper analyzes the characteristics of the enterprise after-sale service records for field failure data, and summarizes the types of field data. Maximum likelihood estimation method and the least squares method are presented for the complexity and difficulty of field failure data processing, and Monte Carlo simulation method is proposed. Monte Carlo simulation, the relatively simple calculation method, is an effective method, whose result is closed to that of the other two methods. Through the after-sale service records analysis of a specific electromagnetic flowmeter enterprises, this paper illustrates the effectiveness of field failure data processing methods.

  3. Failure analysis of single-bolted joint for lightweight composite laminates and metal plate

    Science.gov (United States)

    Li, Linjie; Qu, Junli; Liu, Xiangdong

    2018-01-01

    A three-dimensional progressive damage model was developed in ANSYS to predict the damage accumulation of single bolted joint in composite laminates under in-plane tensile loading. First, we describe the formulation and algorithm of this model. Second, we calculate the failure loads of the joint in fibre reinforced epoxy laminated composite plates and compare it with the experiment results, which validates that our model can appropriately simulate the ultimate tensile strength of the joints and the whole process of failure of structure. Finally, this model is applied to study the failure process of the light-weight composite material (USN125). The study also has a great potential to provide a strong basis for bolted joints design in composite Laminates as well as a simple tool for comparing different laminate geometries and bolt arrangements.

  4. Heart failure in sub-Saharan Africa: review of the aetiology of heart failure and the role of point-of-care biomarker diagnostics.

    Science.gov (United States)

    Glezeva, Nadezhda; Gallagher, Joe; Ledwidge, Mark; O'Donoghue, John; McDonald, Kenneth; Chipolombwe, John; Watson, Chris

    2015-05-01

    Within Africa, the burden of heart failure is significant. This arises from the increase in cardiovascular disease and associated risk factors such as hypertension and diabetes, as well as causes of heart failure which are particular to sub-Saharan Africa, such as endomyocardial fibrosis. The lack of access to echocardiography and other imaging modalities, from a cost and technical perspective, combined with the predominantly rural nature of many countries with poor transport links, means that the vast majority of people never obtain an appropriate diagnosis. Similarly, research has been limited on the causes and treatment of heart failure in Africa and in particular endemic causes such as EMF and rheumatic heart disease. This review outlines the burden of heart failure in Africa and highlights the opportunity to expand diagnosis through the use of biomarkers, in particular natriuretic peptides. This builds on the success of point-of-care testing in human immunodeficiency virus and tuberculosis which have been extensively deployed in community settings in Africa. © 2015 John Wiley & Sons Ltd.

  5. Multiple organ failure in the newborn: the point of view of the pathologist

    Directory of Open Access Journals (Sweden)

    Clara Gerosa

    2014-06-01

    Full Text Available One of the most severe events occurring in critically ill patients admitted to a neonatal intensive care unit (NICU center is represented by the multiple organ failure (MOF, a systemic inflammatory response leading to a progressive organ dysfunction and mortality in newborns. MOF may occur in newborns primarily affected by multiple single organ diseases, including respiratory distress syndrome neonatal sepsis with acute kidney injury, post-asphyxial hypoxic-ischemic encephalopathy and pandemic influenza A (H1N1 infection. In a previous article from our group, based on the histological examination of all organs at autopsy of newborns affected by MOF, all organs studied did not escape to be damaged, including thymus and pancreas normally not mentioned in the literature of MOF. The aim of this article is to review the most important pathological changes pathologists should look for in every case of MOF occurring in the perinatal period, with particular attention to systemic endothelial changes occurring in blood vessels in all organs and sytems. On the basis of our experience, matching data during the last phases of the clinicopathological diagnosis represents a useful method, much more productive as compared to the method based on giving pathological answers to the clinical questions prospected before autopsy. As for the pathological features observed in neonatal MOF, one of them deserves a particular attention: the vascular lesions, and in particular the multiple changes occurring during MOF development in endothelial cells, ending with the loss of the endothelial barrier, probably the most relevant histological lesion followed by the insurgence of interstitial edema and disseminated intravascular coagulation. Small vessels should be observed at high power, with particular attention to the size and shape of endothelial nuclei, in order to evidence endothelial swelling, probably the initial modification of the endothelial cells leading to their

  6. Detection of kinetic change points in piece-wise linear single molecule motion

    Science.gov (United States)

    Hill, Flynn R.; van Oijen, Antoine M.; Duderstadt, Karl E.

    2018-03-01

    Single-molecule approaches present a powerful way to obtain detailed kinetic information at the molecular level. However, the identification of small rate changes is often hindered by the considerable noise present in such single-molecule kinetic data. We present a general method to detect such kinetic change points in trajectories of motion of processive single molecules having Gaussian noise, with a minimum number of parameters and without the need of an assumed kinetic model beyond piece-wise linearity of motion. Kinetic change points are detected using a likelihood ratio test in which the probability of no change is compared to the probability of a change occurring, given the experimental noise. A predetermined confidence interval minimizes the occurrence of false detections. Applying the method recursively to all sub-regions of a single molecule trajectory ensures that all kinetic change points are located. The algorithm presented allows rigorous and quantitative determination of kinetic change points in noisy single molecule observations without the need for filtering or binning, which reduce temporal resolution and obscure dynamics. The statistical framework for the approach and implementation details are discussed. The detection power of the algorithm is assessed using simulations with both single kinetic changes and multiple kinetic changes that typically arise in observations of single-molecule DNA-replication reactions. Implementations of the algorithm are provided in ImageJ plugin format written in Java and in the Julia language for numeric computing, with accompanying Jupyter Notebooks to allow reproduction of the analysis presented here.

  7. Single purse string with four-point traction for better haemorrhoid retraction.

    Science.gov (United States)

    Chen, Shao-Quan; Cai, Ai-Zhen; Wang, Ning; Chen, Lin

    2012-10-01

    Traction method is important to stapled haemorrhoidopexy (SH) for its impact on haemorrhoidal prolapse reduction. Single purse string with one-point traction is most commonly used in SH. This traction method often results in an irregular mucosal doughnut with inadequate height, which leads to insignificant and uneven haemorrhoidal prolapse reduction. Single purse string with two-point traction is a modified traction method. According to some authors, it has significantly improved the height and regularity of the mucosal doughnut in SH. However, the reduction of haemorrhoidal prolapse is not always satisfactory, especially in patients with large prolapse. Our assumption is that single purse string with four-point traction, a more balanced traction method, will provide better control to increase the doughnut height using the same amount of traction. This study was designed to evaluate the outcomes of single purse string with four-point traction as compared with two-point traction in SH. Consecutive patients with symptomatic grade III haemorrhoids were randomized to two groups: Group 1, G(1) ; Group 2, G(2) . Each group underwent SH by colorectal surgeons. The patients in G(1) underwent single purse string with two-point traction. The patients in G(2) underwent SH using single purse string with four-point traction. Preoperative, intraoperative and post-operative patient characteristics were evaluated. Sixty patients with a median age of 44 (range, 21-78) years were identified. Patient demographic and clinical characteristics were similar in the two groups. The height of the mucosectomy specimens significantly increased in patients of G(2) (P string with four-point traction ensures a taller and more regular mucosal doughnut during SH, thus it brings a more satisfactory haemorrhoid retraction. © 2012 The Authors. ANZ Journal of Surgery © 2012 Royal Australasian College of Surgeons.

  8. Estimating Total Heliospheric Magnetic Flux from Single-Point in Situ Measurements

    Science.gov (United States)

    Owens, M. J.; Arge, C. N.; Crooker, N. U.; Schwardron, N. A.; Horbury, T. S.

    2008-01-01

    A fraction of the total photospheric magnetic flux opens to the heliosphere to form the interplanetary magnetic field carried by the solar wind. While this open flux is critical to our understanding of the generation and evolution of the solar magnetic field, direct measurements are generally limited to single-point measurements taken in situ by heliospheric spacecraft. An observed latitude invariance in the radial component of the magnetic field suggests that extrapolation from such single-point measurements to total heliospheric magnetic flux is possible. In this study we test this assumption using estimates of total heliospheric flux from well-separated heliospheric spacecraft and conclude that single-point measurements are indeed adequate proxies for the total heliospheric magnetic flux, though care must be taken when comparing flux estimates from data collected at different heliocentric distances.

  9. Kinematic analysis and fault-tolerant trajectory planning of space manipulator under a single joint failure.

    Science.gov (United States)

    Mu, Zonggao; Han, Liang; Xu, Wenfu; Li, Bing; Liang, Bin

    2016-01-01

    A space manipulator plays an important role in spacecraft capturing, repairing, maintenance, and so on. However, the harsh space environment will cause its joints fail to work. For a non-redundant manipulator, single joint locked failure will cause it to lose one degree of freedom (DOF), hence reducing its movement ability. In this paper, the key problems related to the fault-tolerant including kinematics, workspace, and trajectory planning of a non-redundant space manipulator under single joint failure are handled. First, the analytical inverse kinematics equations are derived for the 5-DOF manipulator formed by locking the failure joint of the original 6-DOF manipulator. Then, the reachable end-effector pose (position and orientation) is determined. Further, we define the missions can be completed by the 5-DOF manipulator. According to the constraints of the on-orbital mission, we determine the grasp envelope required for the end-effector. Combining the manipulability of the manipulator and the performance of its end-effector, a fault tolerance parameter is defined and a planning method is proposed to generate the reasonable trajectory, based on which the 5-DOF manipulator can complete the desired tasks. Finally, typical cases are simulated and the simulation results verify the proposed method.

  10. Soft-Switched Neutral-Point-Clamped Single-Phase Boost Rectifier

    Science.gov (United States)

    Itoh, Ryozo; Ishizaka, Kouichi

    A soft-switched neutral-point-clamped single-phase boost rectifier capable of compensating the imbalance load voltage is studied. This is based on a single-phase rectifier, in which an inductor is placed in series with the AC supply to resonate with a capacitor connected across the DC output of a full-bridge rectifier and the switching transition is mainly governed by a series resonance. The experimental prototype using insulated-gate bipolar transistors is implemented to investigate the operation under the charge control. The experimental results confirm that the rectifier has a neutral-point-clamp feature providing a good quality AC current.

  11. Effect of Crystal Orientation on Fatigue Failure of Single Crystal Nickel Base Turbine Blade Superalloys

    Science.gov (United States)

    Arakere, Nagaraj K.; Swanson, Gregory R.

    2000-01-01

    High Cycle Fatigue (HCF) induced failures in aircraft gas-turbine engines is a pervasive problem affecting a wide range of components and materials. HCF is currently the primary cause of component failures in gas turbine aircraft engines. Turbine blades in high performance aircraft and rocket engines are increasingly being made of single crystal nickel superalloys. Single-crystal Nickel-base superalloys were developed to provide superior creep, stress rupture, melt resistance and thermomechanical fatigue capabilities over polycrystalline alloys previously used in the production of turbine blades and vanes. Currently the most widely used single crystal turbine blade superalloys are PWA 1480/1493 and PWA 1484. These alloys play an important role in commercial, military and space propulsion systems. PWA1493, identical to PWA1480, but with tighter chemical constituent control, is used in the NASA SSME (Space Shuttle Main Engine) alternate turbopump, a liquid hydrogen fueled rocket engine. Objectives for this paper are motivated by the need for developing failure criteria and fatigue life evaluation procedures for high temperature single crystal components, using available fatigue data and finite element modeling of turbine blades. Using the FE (finite element) stress analysis results and the fatigue life relations developed, the effect of variation of primary and secondary crystal orientations on life is determined, at critical blade locations. The most advantageous crystal orientation for a given blade design is determined. Results presented demonstrates that control of secondary and primary crystallographic orientation has the potential to optimize blade design by increasing its resistance to fatigue crack growth without adding additional weight or cost.

  12. A Study of Impulsive Multiterm Fractional Differential Equations with Single and Multiple Base Points and Applications

    Directory of Open Access Journals (Sweden)

    Yuji Liu

    2014-01-01

    Full Text Available We discuss the existence and uniqueness of solutions for initial value problems of nonlinear singular multiterm impulsive Caputo type fractional differential equations on the half line. Our study includes the cases for a single base point fractional differential equation as well as multiple base points fractional differential equation. The asymptotic behavior of solutions for the problems is also investigated. We demonstrate the utility of our work by applying the main results to fractional-order logistic models.

  13. The five-point Likert scale for dyspnea can properly assess the degree of pulmonary congestion and predict adverse events in heart failure outpatients

    OpenAIRE

    Weber, Cristina K.; Miglioranza, Marcelo H.; Moraes, Maria A.P. de; Sant'anna, Roberto T.; Rover, Marciane M.; Kalil, Renato A.K.; Leiria, Tiago Luiz L.

    2014-01-01

    OBJECTIVES: Proper assessment of dyspnea is important in patients with heart failure. Our aim was to evaluate the use of the 5-point Likert scale for dyspnea to assess the degree of pulmonary congestion and to determine the prognostic value of this scale for predicting adverse events in heart failure outpatients. METHODS: We undertook a prospective study of outpatients with moderate to severe heart failure. The 5-point Likert scale was applied during regular outpatient visits, along with cl...

  14. SCAP-82, Single Scattering, Albedo Scattering, Point-Kernel Analysis in Complex Geometry

    International Nuclear Information System (INIS)

    Disney, R.K.; Vogtman, S.E.

    1987-01-01

    1 - Description of problem or function: SCAP solves for radiation transport in complex geometries using the single or albedo scatter point kernel method. The program is designed to calculate the neutron or gamma ray radiation level at detector points located within or outside a complex radiation scatter source geometry or a user specified discrete scattering volume. Geometry is describable by zones bounded by intersecting quadratic surfaces within an arbitrary maximum number of boundary surfaces per zone. Anisotropic point sources are describable as pointwise energy dependent distributions of polar angles on a meridian; isotropic point sources may also be specified. The attenuation function for gamma rays is an exponential function on the primary source leg and the scatter leg with a build- up factor approximation to account for multiple scatter on the scat- ter leg. The neutron attenuation function is an exponential function using neutron removal cross sections on the primary source leg and scatter leg. Line or volumetric sources can be represented as a distribution of isotropic point sources, with un-collided line-of-sight attenuation and buildup calculated between each source point and the detector point. 2 - Method of solution: A point kernel method using an anisotropic or isotropic point source representation is used, line-of-sight material attenuation and inverse square spatial attenuation between the source point and scatter points and the scatter points and detector point is employed. A direct summation of individual point source results is obtained. 3 - Restrictions on the complexity of the problem: - The SCAP program is written in complete flexible dimensioning so that no restrictions are imposed on the number of energy groups or geometric zones. The geometric zone description is restricted to zones defined by boundary surfaces defined by the general quadratic equation or one of its degenerate forms. The only restriction in the program is that the total

  15. The Broad vs. the Pointed Brush: Status Change, Stigma and Blame Following Fast Organizational Failure

    DEFF Research Database (Denmark)

    Andersen, Kristina Vaarst; Lorenzen, Mark; Nowinska, Agnieska

    by a mechanism of blame, i.e. perceived culpability of those displaced employees with comparatively strong association to organizational failure. Comparing this new theoretical notion with the extant notion of stigma, we suggest that while both are mechanisms compensating for imperfect information, stigma....... Using unique hand-collected qualitative and quantitative data, we examine the careers of the organization’s displaced employees. At odds with extant theory on stigma, we do not find any general status loss. We explain this by the fast decline and aftermath after bankruptcy of this particular...... organization, allowing insufficient time for a stigmatization mechanism. We find that displaced employees most prone to status loss are those having worked organizationally and geographically proximately to the locus of the organization’s failure. We suggest that in lieu of stigma, status change is driven...

  16. Estimated GFR Decline as a Surrogate End Point for Kidney Failure

    DEFF Research Database (Denmark)

    Lambers Heerspink, Hiddo J; Weldegiorgis, Misghina; Inker, Lesley A

    2014-01-01

    A doubling of serum creatinine value, corresponding to a 57% decline in estimated glomerular filtration rate (eGFR), is used frequently as a component of a composite kidney end point in clinical trials in type 2 diabetes. The aim of this study was to determine whether alternative end points defined...

  17. Bayesian unknown change-point models to investigate immediacy in single case designs.

    Science.gov (United States)

    Natesan, Prathiba; Hedges, Larry V

    2017-12-01

    Although immediacy is one of the necessary criteria to show strong evidence of a causal relation in single case designs (SCDs), no inferential statistical tool is currently used to demonstrate it. We propose a Bayesian unknown change-point model to investigate and quantify immediacy in SCD analysis. Unlike visual analysis that considers only 3-5 observations in consecutive phases to investigate immediacy, this model considers all data points. Immediacy is indicated when the posterior distribution of the unknown change-point is narrow around the true value of the change-point. This model can accommodate delayed effects. Monte Carlo simulation for a 2-phase design shows that the posterior standard deviations of the change-points decrease with increase in standardized mean difference between phases and decrease in test length. This method is illustrated with real data. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Single-Molecule Counting of Point Mutations by Transient DNA Binding

    Science.gov (United States)

    Su, Xin; Li, Lidan; Wang, Shanshan; Hao, Dandan; Wang, Lei; Yu, Changyuan

    2017-03-01

    High-confidence detection of point mutations is important for disease diagnosis and clinical practice. Hybridization probes are extensively used, but are hindered by their poor single-nucleotide selectivity. Shortening the length of DNA hybridization probes weakens the stability of the probe-target duplex, leading to transient binding between complementary sequences. The kinetics of probe-target binding events are highly dependent on the number of complementary base pairs. Here, we present a single-molecule assay for point mutation detection based on transient DNA binding and use of total internal reflection fluorescence microscopy. Statistical analysis of single-molecule kinetics enabled us to effectively discriminate between wild type DNA sequences and single-nucleotide variants at the single-molecule level. A higher single-nucleotide discrimination is achieved than in our previous work by optimizing the assay conditions, which is guided by statistical modeling of kinetics with a gamma distribution. The KRAS c.34 A mutation can be clearly differentiated from the wild type sequence (KRAS c.34 G) at a relative abundance as low as 0.01% mutant to WT. To demonstrate the feasibility of this method for analysis of clinically relevant biological samples, we used this technology to detect mutations in single-stranded DNA generated from asymmetric RT-PCR of mRNA from two cancer cell lines.

  19. Evaluating Change in Behavioral Preferences: Multidimensional Scaling Single-Ideal Point Model

    Science.gov (United States)

    Ding, Cody

    2016-01-01

    The purpose of the article is to propose a multidimensional scaling single-ideal point model as a method to evaluate changes in individuals' preferences under the explicit methodological framework of behavioral preference assessment. One example is used to illustrate the approach for a clear idea of what this approach can accomplish.

  20. Mechanism of DNA–binding loss upon single-point mutation in p53

    Indian Academy of Sciences (India)

    PRAKASH KUMAR

    provides an excellent prototype system to elucidate the different mechanisms underlying the loss in DNA binding affinity and specificity upon single point mutation because over 50% of all human cancers involve p53 mutations, which occur mostly in the sequence–specific DNA–binding central domain (residues 102–292, ...

  1. Single stage buck-boost DC-AC neutral point clamped inverter

    DEFF Research Database (Denmark)

    Mo, Wei; Loh, Poh Chiang; Andrew, A.

    2012-01-01

    This paper proposes a new single stage buck-boost DC-AC neutral point clamped inverter topology which integrates the cascaded configurations of recently introduced inductor-capacitor-capacitor-transformer impedance source network (by Adamowicz) and classic NPC configuration. As a consequence...

  2. Real-time multi-GNSS single-frequency precise point positioning

    NARCIS (Netherlands)

    de Bakker, P.F.; Tiberius, C.C.J.M.

    2017-01-01

    Precise Point Positioning (PPP) is a popular Global Positioning System (GPS) processing strategy, thanks to its high precision without requiring additional GPS infrastructure. Single-Frequency PPP (SF-PPP) takes this one step further by no longer relying on expensive dual-frequency GPS receivers,

  3. MedLink: A Mobile Intervention to Address Failure Points in the Treatment of Depression in General Medicine

    Directory of Open Access Journals (Sweden)

    David Mohr

    2015-11-01

    Full Text Available Major depression is common, and imposes Major depression is common, and imposes a high burden in terms of cost, morbidity, and suffering. Most people with depression are treated in general medicine using antidepressant medication. Outcomes are poor due to failure points across the care system, including patient non-adherence, failure of physicians to optimize the treatment regimens, and lack of patient-physician communication. This study reports on the 4-week pilot deployment of MedLink, a mobile intervention aimed at systemically addressing each of these failure points. A mobile app provides the patient with information and collects data on symptoms and side-effects. A cellularly enabled pill bottle monitors medication adherence. Data from these are provided to the physician and patient to foster communication and medication adjustments. Usability evaluation was generally favorable. Medication adherence rates in this first deployment were high with no patients discontinuing, and 84% of doses taken. Depressive symptom severity was significantly reduced. This study supports the use of a comprehensive, systemic approach to mHealth solutions to enhance processes of care for depression by general medicine physicians.

  4. SINGLE TREE DETECTION FROM AIRBORNE LASER SCANNING DATA USING A MARKED POINT PROCESS BASED METHOD

    Directory of Open Access Journals (Sweden)

    J. Zhang

    2013-05-01

    Full Text Available Tree detection and reconstruction is of great interest in large-scale city modelling. In this paper, we present a marked point process model to detect single trees from airborne laser scanning (ALS data. We consider single trees in ALS recovered canopy height model (CHM as a realization of point process of circles. Unlike traditional marked point process, we sample the model in a constraint configuration space by making use of image process techniques. A Gibbs energy is defined on the model, containing a data term which judge the fitness of the model with respect to the data, and prior term which incorporate the prior knowledge of object layouts. We search the optimal configuration through a steepest gradient descent algorithm. The presented hybrid framework was test on three forest plots and experiments show the effectiveness of the proposed method.

  5. Generating and executing programs for a floating point single instruction multiple data instruction set architecture

    Science.gov (United States)

    Gschwind, Michael K

    2013-04-16

    Mechanisms for generating and executing programs for a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA) are provided. A computer program product comprising a computer recordable medium having a computer readable program recorded thereon is provided. The computer readable program, when executed on a computing device, causes the computing device to receive one or more instructions and execute the one or more instructions using logic in an execution unit of the computing device. The logic implements a floating point (FP) only single instruction multiple data (SIMD) instruction set architecture (ISA), based on data stored in a vector register file of the computing device. The vector register file is configured to store both scalar and floating point values as vectors having a plurality of vector elements.

  6. PowerPoint® presentation flaws and failures: a psychological analysis

    NARCIS (Netherlands)

    Kosslyn, S.M.; Kievit, R.A.; Russell, A.G.; Shepard, J.M.

    2012-01-01

    Electronic slideshow presentations are often faulted anecdotally, but little empirical work has documented their faults. In Study 1 we found that eight psychological principles are often violated in PowerPoint® slideshows, and are violated to similar extents across different fields - for example,

  7. Point defects in lines in single crystalline phosphorene: directional migration and tunable band gaps.

    Science.gov (United States)

    Li, Xiuling; Ma, Liang; Wang, Dayong; Zeng, Xiao Cheng; Wu, Xiaojun; Yang, Jinlong

    2016-10-20

    Extended line defects in two-dimensional (2D) materials can play an important role in modulating their electronic properties. During the experimental synthesis of 2D materials, line defects are commonly generated at grain boundaries between domains of different orientations. In this work, twelve types of line-defect structures in single crystalline phosphorene are examined by using first-principles calculations. These line defects are typically formed via migration and aggregation of intrinsic point defects, including the Stone-Wales (SW), single or double vacancy (SV or DV) defects. Our calculated results demonstrate that the migration of point defects in phosphorene is anisotropic, for instance, the lowest migration energy barriers are 1.39 (or 0.40) and 2.58 (or 0.49) eV for SW (or SV) defects in zigzag and armchair directions, respectively. The aggregation of point defects into lines is energetically favorable compared with the separated point defects in phosphorene. In particular, the axis of line defects in phosphorene is direction-selective, depending on the composed point defects. The presence of line defects effectively modulates the electronic properties of phosphorene, rendering the defect-containing phosphorene either metallic or semiconducting with a tunable band gap. Of particular interest is the fact that the SV-based line defect can behave as a metallic wire, suggesting a possibility to fabricate a circuit with subnanometer widths in the semiconducting phosphorene for nanoscale electronic application.

  8. Design of an omnidirectional single-point photodetector for large-scale spatial coordinate measurement

    Science.gov (United States)

    Xie, Hongbo; Mao, Chensheng; Ren, Yongjie; Zhu, Jigui; Wang, Chao; Yang, Lei

    2017-10-01

    In high precision and large-scale coordinate measurement, one commonly used approach to determine the coordinate of a target point is utilizing the spatial trigonometric relationships between multiple laser transmitter stations and the target point. A light receiving device at the target point is the key element in large-scale coordinate measurement systems. To ensure high-resolution and highly sensitive spatial coordinate measurement, a high-performance and miniaturized omnidirectional single-point photodetector (OSPD) is greatly desired. We report one design of OSPD using an aspheric lens, which achieves an enhanced reception angle of -5 deg to 45 deg in vertical and 360 deg in horizontal. As the heart of our OSPD, the aspheric lens is designed in a geometric model and optimized by LightTools Software, which enables the reflection of a wide-angle incident light beam into the single-point photodiode. The performance of home-made OSPD is characterized with working distances from 1 to 13 m and further analyzed utilizing developed a geometric model. The experimental and analytic results verify that our device is highly suitable for large-scale coordinate metrology. The developed device also holds great potential in various applications such as omnidirectional vision sensor, indoor global positioning system, and optical wireless communication systems.

  9. Identification of Intensity Ratio Break Points from Photon Arrival Trajectories in Ratiometric Single Molecule Spectroscopy

    Science.gov (United States)

    Bingemann, Dieter; Allen, Rachel M.

    2012-01-01

    We describe a statistical method to analyze dual-channel photon arrival trajectories from single molecule spectroscopy model-free to identify break points in the intensity ratio. Photons are binned with a short bin size to calculate the logarithm of the intensity ratio for each bin. Stochastic photon counting noise leads to a near-normal distribution of this logarithm and the standard student t-test is used to find statistically significant changes in this quantity. In stochastic simulations we determine the significance threshold for the t-test’s p-value at a given level of confidence. We test the method’s sensitivity and accuracy indicating that the analysis reliably locates break points with significant changes in the intensity ratio with little or no error in realistic trajectories with large numbers of small change points, while still identifying a large fraction of the frequent break points with small intensity changes. Based on these results we present an approach to estimate confidence intervals for the identified break point locations and recommend a bin size to choose for the analysis. The method proves powerful and reliable in the analysis of simulated and actual data of single molecule reorientation in a glassy matrix. PMID:22837704

  10. Incorporating single detector failure into the ROP detector layout optimization for CANDU reactors

    International Nuclear Information System (INIS)

    Kastanya, Doddy

    2015-01-01

    Highlights: • ROP TSP value needs to be adjusted when any detector in the system fails. • Single detector failure criterion has been incorporated into the detector layout optimization as a constraint. • Results show that the optimized detector layout is more robust with respect to its vulnerability to a single detector failure. • An early rejection scheme has been introduced to speed-up the optimization process. - Abstract: In CANDU ® reactors, the regional overpower protection (ROP) systems are designed to protect the reactor against overpower in the fuel which could reduce the safety margin-to-dryout. In the CANDU ® 600 MW (CANDU 6) design, there are two ROP systems in the core, each of which is connected to a fast-acting shutdown system. Each ROP system consists of a number of fast-responding, self-powered flux detectors suitably distributed throughout the core within vertical and horizontal flux detector assemblies. The placement of these ROP detectors is a challenging discrete optimization problem. In the past few years, two algorithms, DETPLASA and ADORE, have been developed to optimize the detector layout for the ROP systems in CANDU reactors. These algorithms utilize the simulated annealing (SA) technique to optimize the placement of the detectors in the core. The objective of the optimization process is typically either to maximize the TSP value for a given number of detectors in the system or to minimize the number of detectors in the system to obtain a target TSP value. One measure to determine the robustness of the optimized detector layout is to evaluate the maximum decrease (penalty) in TSP value when any single detector in the system fails. The smaller the penalty, the more robust the design is. Therefore, in order to ensure that the optimized detector layout is robust, the single detector failure (SDF) criterion has been incorporated as an additional constraint into the ADORE algorithm. Results from this study indicate that there is a

  11. Incorporating single detector failure into the ROP detector layout optimization for CANDU reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kastanya, Doddy, E-mail: Doddy.Kastanya@snclavalin.com

    2015-12-15

    Highlights: • ROP TSP value needs to be adjusted when any detector in the system fails. • Single detector failure criterion has been incorporated into the detector layout optimization as a constraint. • Results show that the optimized detector layout is more robust with respect to its vulnerability to a single detector failure. • An early rejection scheme has been introduced to speed-up the optimization process. - Abstract: In CANDU{sup ®} reactors, the regional overpower protection (ROP) systems are designed to protect the reactor against overpower in the fuel which could reduce the safety margin-to-dryout. In the CANDU{sup ®} 600 MW (CANDU 6) design, there are two ROP systems in the core, each of which is connected to a fast-acting shutdown system. Each ROP system consists of a number of fast-responding, self-powered flux detectors suitably distributed throughout the core within vertical and horizontal flux detector assemblies. The placement of these ROP detectors is a challenging discrete optimization problem. In the past few years, two algorithms, DETPLASA and ADORE, have been developed to optimize the detector layout for the ROP systems in CANDU reactors. These algorithms utilize the simulated annealing (SA) technique to optimize the placement of the detectors in the core. The objective of the optimization process is typically either to maximize the TSP value for a given number of detectors in the system or to minimize the number of detectors in the system to obtain a target TSP value. One measure to determine the robustness of the optimized detector layout is to evaluate the maximum decrease (penalty) in TSP value when any single detector in the system fails. The smaller the penalty, the more robust the design is. Therefore, in order to ensure that the optimized detector layout is robust, the single detector failure (SDF) criterion has been incorporated as an additional constraint into the ADORE algorithm. Results from this study indicate that there

  12. Single point incremental forming of tailored blanks produced by friction stir welding

    DEFF Research Database (Denmark)

    Silva, M.B.; Skjødt, Martin; Vilaca, P.

    2009-01-01

    This paper is focused on the single point incremental forming (SPIF) of tailored welded blanks produced by friction stirwelding (FSW). Special emphasis is placed on the know-how for producing the tailored blanks and on the utilization of innovative forming strategies to protect thewelding joint...... fromthe rotating single point-forming tool. Formability of the tailor welded blanks (TWB) is evaluated by means of benchmark tests carried out on truncated conical and pyramidal shapes and results are compared with similar tests performed on conventional reference blanks of the same material. Results show...... that the combination of SPIF with tailored welded blanks produced by FSW seems promising in the manufacture of complex sheet metal parts with high depths....

  13. Point defects and magnetic properties of neutron irradiated MgO single crystal

    Directory of Open Access Journals (Sweden)

    Mengxiong Cao

    2017-05-01

    Full Text Available (100-oriented MgO single crystals were irradiated to introduce point defects with different neutron doses ranging from 1.0×1016 to 1.0×1020 cm-2. The point defect configurations were studied with X-ray diffuse scattering and UV-Vis absorption spectra. The isointensity profiles of X-ray diffuse scattering caused by the cubic and double-force point defects in MgO were theoretically calculated based on the Huang scattering theory. The magnetic properties at different temperature were measured with superconducting quantum interference device (SQUID. The reciprocal space mappings (RSMs of irradiated MgO revealed notable diffuse scattering. The UV-Vis spectra indicated the presence of O Frenkel defects in irradiated MgO. Neutron-irradiated MgO was diamagnetic at room temperature and became ferromagnetic at low temperature due to O Frenkel defects induced by neutron-irradiation.

  14. Exposure buildup factors for a cobalt-60 point isotropic source for single and two layer slabs

    International Nuclear Information System (INIS)

    Chakarova, R.

    1992-01-01

    Exposure buildup factors for point isotropic cobalt-60 sources are calculated by the Monte Carlo method with statistical errors ranging from 1.5 to 7% for 1-5 mean free paths (mfp) thick water and iron single slabs and for 1 and 2 mfp iron layers followed by water layers 1-5 mfp thick. The computations take into account Compton scattering. The Monte Carlo data for single slab geometries are approximated by Geometric Progression formula. Kalos's formula using the calculated single slab buildup factors may be applied to reproduce the data for two-layered slabs. The presented results and discussion may help when choosing the manner in which the radiation field gamma irradiation units will be described. (author)

  15. The consistency condition for the three-point function in dissipative single-clock inflation

    International Nuclear Information System (INIS)

    Nacir, Diana López; Porto, Rafael A.; Zaldarriaga, Matias

    2012-01-01

    We generalize the consistency condition for the three-point function in single field inflation to the case of dissipative, multi-field, single-clock models. We use the recently introduced extension of the effective field theory of inflation that accounts for dissipative effects, to provide an explicit proof to leading (non-trivial) order in the generalized slow roll parameters and mixing with gravity scales. Our results illustrate the conditions necessary for the validity of the consistency relation in situations with many degrees of freedom relevant during inflation, namely that there is a preferred clock. Departures from this condition in forthcoming experiments would rule out not only single field but also a large class of multi-field models

  16. The consistency condition for the three-point function in dissipative single-clock inflation

    Energy Technology Data Exchange (ETDEWEB)

    Nacir, Diana López [Departamento de Física, Facultad de Ciencias Exactas y Naturales, UBA and IFIBA, CONICET, Ciudad Universitaria, Pabellón 1, 1428, Buenos Aires (Argentina); Porto, Rafael A.; Zaldarriaga, Matias, E-mail: dnacir@df.uba.ar, E-mail: rporto@ias.edu, E-mail: matiasz@ias.edu [School of Natural Sciences, Institute for Advanced Study, Einstein Drive, Princeton, NJ 08540 (United States)

    2012-09-01

    We generalize the consistency condition for the three-point function in single field inflation to the case of dissipative, multi-field, single-clock models. We use the recently introduced extension of the effective field theory of inflation that accounts for dissipative effects, to provide an explicit proof to leading (non-trivial) order in the generalized slow roll parameters and mixing with gravity scales. Our results illustrate the conditions necessary for the validity of the consistency relation in situations with many degrees of freedom relevant during inflation, namely that there is a preferred clock. Departures from this condition in forthcoming experiments would rule out not only single field but also a large class of multi-field models.

  17. Single Point Incremental Forming to increase material knowledge and production flexibility

    Science.gov (United States)

    Habraken, A. M.

    2016-08-01

    Nowadays, manufactured pieces can be divided into two groups: mass production and production of low volume number of parts. Within the second group (prototyping or small batch production), an emerging solution relies on Incremental Sheet Forming or ISF. ISF refers to processes where the plastic deformation occurs by repeated contact with a relatively small tool. More specifically, many publications over the past decade investigate Single Point Incremental Forming (SPIF) where the final shape is determined only by the tool movement. This manufacturing process is characterized by the forming of sheets by means of a CNC controlled generic tool stylus, with the sheets clamped by means of a non-workpiece-specific clamping system and in absence of a partial or a full die. The advantage is no tooling requirements and often enhanced formability, however it poses a challenge in term of process control and accuracy assurance. Note that the most commonly used materials in incremental forming are aluminum and steel alloys however other alloys are also used especially for medical industry applications, such as cobalt and chromium alloys, stainless steel and titanium alloys. Some scientists have applied incremental forming on PVC plates and other on sandwich panels composed of propylene with mild steel and aluminum metallic foams with aluminum sheet metal. Micro incremental forming of thin foils has also been developed. Starting from the scattering of the results of Finite Element (FE) simulations, when one tries to predict the tool force (see SPIF benchmark of 2014 Numisheet conference), we will see how SPIF and even micro SPIF (process applied on thin metallic sheet with a few grains within the thickness) allow investigating the material behavior. This lecture will focus on the identification of constitutive laws, on the SPIF forming mechanisms and formability as well as the failure mechanism. Different hypotheses have been proposed to explain SPIF formability, they will be

  18. PowerPoint® Presentation Flaws and Failures: A Psychological Analysis

    Science.gov (United States)

    Kosslyn, Stephen M.; Kievit, Rogier A.; Russell, Alexandra G.; Shephard, Jennifer M.

    2012-01-01

    Electronic slideshow presentations are often faulted anecdotally, but little empirical work has documented their faults. In Study 1 we found that eight psychological principles are often violated in PowerPoint® slideshows, and are violated to similar extents across different fields – for example, academic research slideshows generally were no better or worse than business slideshows. In Study 2 we found that respondents reported having noticed, and having been annoyed by, specific problems in presentations arising from violations of particular psychological principles. Finally, in Study 3 we showed that observers are not highly accurate in recognizing when particular slides violated a specific psychological rule. Furthermore, even when they correctly identified the violation, they often could not explain the nature of the problem. In sum, the psychological foundations for effective slideshow presentation design are neither obvious nor necessarily intuitive, and presentation designers in all fields, from education to business to government, could benefit from explicit instruction in relevant aspects of psychology. PMID:22822402

  19. PowerPoint(®) Presentation Flaws and Failures: A Psychological Analysis.

    Science.gov (United States)

    Kosslyn, Stephen M; Kievit, Rogier A; Russell, Alexandra G; Shephard, Jennifer M

    2012-01-01

    Electronic slideshow presentations are often faulted anecdotally, but little empirical work has documented their faults. In Study 1 we found that eight psychological principles are often violated in PowerPoint(®) slideshows, and are violated to similar extents across different fields - for example, academic research slideshows generally were no better or worse than business slideshows. In Study 2 we found that respondents reported having noticed, and having been annoyed by, specific problems in presentations arising from violations of particular psychological principles. Finally, in Study 3 we showed that observers are not highly accurate in recognizing when particular slides violated a specific psychological rule. Furthermore, even when they correctly identified the violation, they often could not explain the nature of the problem. In sum, the psychological foundations for effective slideshow presentation design are neither obvious nor necessarily intuitive, and presentation designers in all fields, from education to business to government, could benefit from explicit instruction in relevant aspects of psychology.

  20. Single-stage Kanban system with deterioration failures and condition-based preventive maintenance

    International Nuclear Information System (INIS)

    Xanthopoulos, A.S.; Koulouriotis, D.E.; Botsaris, P.N.

    2015-01-01

    Despite the fact that the fields of pull type production control policies and condition-based preventive maintenance have much in common contextually, they have evolved independently up to now. In this investigation, an attempt is made to bridge the gap between these two branches of knowledge by introducing the single-stage Kanban system with deterioration failures and condition-based preventive maintenance. The formalism of continuous time Markov chains is used to model the system and expressions for eight performance metrics are derived. Two important, from a managerial perspective, constrained optimization problems for the proposed model are defined where the objective is the simultaneous optimization of the Kanban policy, the preventive maintenance policy and the inspection schedule under conflicting performance criteria. Multiple instances of each optimization problem are solved by means of the augmented Lagrangian genetic algorithm. The results from the optimization trials coupled by the results from extensive numerical examples facilitate the thorough investigation of the system’s behaviour. - Highlights: • Kanban system with deterioration failures and preventive maintenance is introduced. • The system is modeled as a continuous time Markov chain. • Expressions for eight performance metrics are derived. • The behavior of the system is studied through numerical examples. • Optimization results for selected performance metrics are presented

  1. A physics-based framework for spall failure of single crystals

    Science.gov (United States)

    Nguyen, Thao; Luscher, D. J.; Wilkerson, Justin

    2017-06-01

    A framework for dislocation-based viscoplasticity and dynamic ductile failure has been developed to model high strain rate deformation and damage in single crystals. The rate-dependence of the crystal plasticity formulation is based on the physics of relativistic dislocation kinetics suited for extremely high strain rates. The damage evolution is based on the dynamics of void growth, which are governed by both micro-inertia as well as dislocation kinetics and dislocation substructure evolution. The resulting homogenized framework has been implemented into a commercially available finite element package, and a fairly extensive validation study against a suite of direct numerical simulations was carried out. The utility of the homogenized framework is further demonstrated through the mesoscale simulation of a polycrystal subject to dynamic loading. The simulations capture some key experimentally-observed features of damage localization along grain boundaries of particular misorientation.

  2. PowerPoint® Presentation Flaws and Failures: A Psychological Analysis

    Directory of Open Access Journals (Sweden)

    Stephen Michael Kosslyn

    2012-07-01

    Full Text Available Electronic slideshow presentations are often faulted anecdotally, but little empirical work has documented their faults. Three studies reported here document psychological causes of their flaws. In Study 1 we found that eight psychological principles are often violated in PowerPoint® presentations, across different fields—for example, academic research presentations generally were no better or worse than business presentations. In Study 2 we found that respondents reported having noticed, and having been annoyed by, specific problems in presentations arising from violations of particular psychological principles. Finally, in Study 3 we showed that observers are not highly accurate in recognizing when slides violated a specific psychological rule. Furthermore, even when they correctly identified the violation, they often could not explain the nature of the problem. In sum, the psychological foundations for effective slideshow presentation design are neither obvious nor necessarily intuitive, and presentation designers in all fields, from education to business to government, could benefit from explicit instruction in relevant aspects of psychology.

  3. A dislocation-based crystal plasticity framework for dynamic ductile failure of single crystals

    Science.gov (United States)

    Nguyen, Thao; Luscher, D. J.; Wilkerson, J. W.

    2017-11-01

    A framework for dislocation-based viscoplasticity and dynamic ductile failure has been developed to model high strain rate deformation and damage in single crystals. The rate-dependence of the crystal plasticity formulation is based on the physics of relativistic dislocation kinetics suited for extremely high strain rates. The damage evolution is based on the dynamics of void growth, which are governed by both micro-inertia as well as dislocation kinetics and dislocation substructure evolution. An averaging scheme is proposed in order to approximate the evolution of the dislocation substructure in both the macroscale as well as its spatial distribution at the microscale. Additionally, a concept of a single equivalent dislocation density that effectively captures the collective influence of dislocation density on all active slip systems is proposed here. Together, these concepts and approximations enable the use of semi-analytic solutions for void growth dynamics developed in (Wilkerson and Ramesh, 2014), which greatly reduce the computational overhead that would otherwise be required. The resulting homogenized framework has been implemented into a commercially available finite element package, and a validation study against a suite of direct numerical simulations was carried out.

  4. Ultrasonography for suspected deep vein thrombosis: how useful is single-point augmentation?

    Energy Technology Data Exchange (ETDEWEB)

    McQueen, A.S. [Department of Radiology, Freeman Hospital, Newcastle upon Tyne (United Kingdom)], E-mail: andrewmcqueen7@hotmail.com; Elliott, S.T. [Department of Radiology, Freeman Hospital, Newcastle upon Tyne (United Kingdom); Keir, M.J. [Department of Medical Physics, Royal Victoria Infirmary, Newcastle upon Tyne (United Kingdom)

    2009-02-15

    Aims: To assess the role of single-point augmentation of spectral Doppler flow in the diagnosis of acute deep vein thrombosis (DVT). Secondary objectives included identifying the augmentation response in non-DVT diagnoses. Methods: Patients attending the ultrasound departments of two hospitals for investigation of suspected acute DVT during an 8-month period were recruited to the study group. Spectral Doppler assessment of the superficial femoral vein was recorded during Valsalva and calf compression manoeuvres in the asymptomatic and symptomatic legs. The Doppler waveforms from the symptomatic limb were characterized as 'normal' or 'abnormal' by the operator. Standard compression ultrasonography of the symptomatic leg was then performed with the presence of DVT or an alternative diagnosis documented. Results: One hundred and sixty-seven patients underwent ultrasound examinations using the study methodology. Nine patients were subsequently excluded due to bilateral DVT or inability to tolerate calf compression. The mean age of the remaining 158 patients was 65.4 years with 28 DVTs identified (18% of patients). Calf compression elicited a normal response in 118/130 of non-DVT examinations (specificity 91%) and an abnormal response in 18/28 DVT examinations (sensitivity 64%). Diminished or absent augmentation was identified in alternative diagnoses that included haematoma and Baker's cyst. Conclusions: This study demonstrates that single-point augmentation has a low sensitivity in suspected lower-limb DVT, and that the majority of undetected DVTs are isolated to the calf veins. An abnormal augmentation response is a poor predictor of lower-limb DVT as alternative diagnoses can produce diminished or reduced augmentation. Therefore, single-point augmentation does not add to the standard compression ultrasound examination for suspected DVT and should not be routinely performed.

  5. Ultrasonography for suspected deep vein thrombosis: how useful is single-point augmentation?

    International Nuclear Information System (INIS)

    McQueen, A.S.; Elliott, S.T.; Keir, M.J.

    2009-01-01

    Aims: To assess the role of single-point augmentation of spectral Doppler flow in the diagnosis of acute deep vein thrombosis (DVT). Secondary objectives included identifying the augmentation response in non-DVT diagnoses. Methods: Patients attending the ultrasound departments of two hospitals for investigation of suspected acute DVT during an 8-month period were recruited to the study group. Spectral Doppler assessment of the superficial femoral vein was recorded during Valsalva and calf compression manoeuvres in the asymptomatic and symptomatic legs. The Doppler waveforms from the symptomatic limb were characterized as 'normal' or 'abnormal' by the operator. Standard compression ultrasonography of the symptomatic leg was then performed with the presence of DVT or an alternative diagnosis documented. Results: One hundred and sixty-seven patients underwent ultrasound examinations using the study methodology. Nine patients were subsequently excluded due to bilateral DVT or inability to tolerate calf compression. The mean age of the remaining 158 patients was 65.4 years with 28 DVTs identified (18% of patients). Calf compression elicited a normal response in 118/130 of non-DVT examinations (specificity 91%) and an abnormal response in 18/28 DVT examinations (sensitivity 64%). Diminished or absent augmentation was identified in alternative diagnoses that included haematoma and Baker's cyst. Conclusions: This study demonstrates that single-point augmentation has a low sensitivity in suspected lower-limb DVT, and that the majority of undetected DVTs are isolated to the calf veins. An abnormal augmentation response is a poor predictor of lower-limb DVT as alternative diagnoses can produce diminished or reduced augmentation. Therefore, single-point augmentation does not add to the standard compression ultrasound examination for suspected DVT and should not be routinely performed

  6. Assessment of Grade-Level Differences in Coping Behavior among Adolescents Using Multidimensional Scaling Single-Ideal-Point Model

    Science.gov (United States)

    Ding, Cody; Yang, Dong

    2013-01-01

    The purpose of the study was to examine grade-level differences in coping behaviors among adolescents using a probabilistic multidimensional scaling (MDS) single-ideal-point model. Using data from students in middle school and at college, this article illustrated the MDS single-ideal-point model as an alternative to examine students' typical…

  7. Probing Critical Point Energies of Transition Metal Dichalcogenides: Surprising Indirect Gap of Single Layer WSe 2

    KAUST Repository

    Zhang, Chendong

    2015-09-21

    By using a comprehensive form of scanning tunneling spectroscopy, we have revealed detailed quasi-particle electronic structures in transition metal dichalcogenides, including the quasi-particle gaps, critical point energy locations, and their origins in the Brillouin zones. We show that single layer WSe surprisingly has an indirect quasi-particle gap with the conduction band minimum located at the Q-point (instead of K), albeit the two states are nearly degenerate. We have further observed rich quasi-particle electronic structures of transition metal dichalcogenides as a function of atomic structures and spin-orbit couplings. Such a local probe for detailed electronic structures in conduction and valence bands will be ideal to investigate how electronic structures of transition metal dichalcogenides are influenced by variations of local environment.

  8. Efficient Background Segmentation and Seed Point Generation for a Single-Shot Stereo System

    Science.gov (United States)

    Chen, Xiaobo; Xi, Juntong

    2017-01-01

    Single-shot stereo 3D shape measurement is becoming more popular due to its advantages of noise robustness and short acquisition period. One of the key problems is stereo matching, which is related to the efficiency of background segmentation and seed point generation, etc. In this paper, a more efficient and automated matching algorithm based on digital image correlation (DIC) is proposed. The standard deviation of image gradients and an adaptive threshold are employed to segment the background. Scale-invariant feature transform (SIFT)-based feature matching and two-dimensional triangulation are combined to estimate accurate initial parameters for seed point generation. The efficiency of background segmentation and seed point generation, as well as the measuring precision, are evaluated by experimental simulation and real tests. Experimental results show that the average segmentation time for an image with a resolution of 1280 × 960 pixels is 240 milliseconds. The efficiency of seed point generation is verified to be high with different convergence criteria. PMID:29194415

  9. Structure Based Thermostability Prediction Models for Protein Single Point Mutations with Machine Learning Tools.

    Directory of Open Access Journals (Sweden)

    Lei Jia

    Full Text Available Thermostability issue of protein point mutations is a common occurrence in protein engineering. An application which predicts the thermostability of mutants can be helpful for guiding decision making process in protein design via mutagenesis. An in silico point mutation scanning method is frequently used to find "hot spots" in proteins for focused mutagenesis. ProTherm (http://gibk26.bio.kyutech.ac.jp/jouhou/Protherm/protherm.html is a public database that consists of thousands of protein mutants' experimentally measured thermostability. Two data sets based on two differently measured thermostability properties of protein single point mutations, namely the unfolding free energy change (ddG and melting temperature change (dTm were obtained from this database. Folding free energy change calculation from Rosetta, structural information of the point mutations as well as amino acid physical properties were obtained for building thermostability prediction models with informatics modeling tools. Five supervised machine learning methods (support vector machine, random forests, artificial neural network, naïve Bayes classifier, K nearest neighbor and partial least squares regression are used for building the prediction models. Binary and ternary classifications as well as regression models were built and evaluated. Data set redundancy and balancing, the reverse mutations technique, feature selection, and comparison to other published methods were discussed. Rosetta calculated folding free energy change ranked as the most influential features in all prediction models. Other descriptors also made significant contributions to increasing the accuracy of the prediction models.

  10. Optical Properties And Thermal Stability Of Single-Point Diamond-Machined Aluminum Alloys

    Science.gov (United States)

    Ogloza, A. A.; Decker, D. L.; Archibald, P. C.; O'Connor, D. A.; Bueltmann, E. R.

    1989-01-01

    This paper presents the results of diamond-turned surfaces of a wide range of aluminum alloys. The alloys machined included a sand-cast A201 alloy manufactured by Specialty Aluminum Inc., conventionally extruded plate alloys 2024, 3003, 5052, 6061, 7075, and for comparison as a best and worst case possible a high-purity aluminum single crystal, and tooling plate. The surfaces were obtained by diamond single-point machining using an interferometrically controlled two-axis, air-bearing lathe. The effect of tool-rake angle and machining fluid on surface quality is examined. Surface characterization was performed by Nomarski microscopy and noncontact optical surface profilometry. The optical properties measured included absolute reflectance at 3.8 μm, total integrated scatter at 752.5 nm, and bidirectional reflection distribution function measurements at 632.8 nm. The dimensional stability of the aluminum alloys subject to thermal cycling is examined.

  11. An advanced chronic heart failure day care service: a 5 year single-center experience.

    Science.gov (United States)

    Freimark, Dov; Arad, Michael; Matetzky, Shlomi; DeNeen, Isabell; Gershovitz, Liron; Morag, Nira Koren; Hochberg, Naomi; Makmal, Yafit; Shechter, Michael

    2009-07-01

    Chronic heart failure is associated with excessive hospitalizations and poor prognosis. To summarize the 5 year experience of a single-center CHF day care service, detect the cardiovascular and non-cardiovascular events, and evaluate the safety of the treatments provided. We retrospectively studied all patients admitted to the CHF day care service of the Sheba Medical Center between September 2000 and September 2005. Advanced (New York Heart Association class III-IV) CHF patients (n = 190), mean age 65 +/- 12 years and left ventricular ejection fraction 25 +/- 11%, were treated for 6 hourly biweekly visits; 77% had ischemic and 23% had nonischemic cardiomyopathy. Treatment included: intravenous diuretic combinations (91%), intermittent low dose (< or = 5 microg/kg/min) dobutamine (87%), low dose (< or = 3 microg/kg/min) dopamine (38%), intravenous iron preparation and/or blood (47%), and intravenous nitropruside (36%). Follow-up of at least 1 year from initiation of therapy was completed in 158 of 190 patients (83%). Forty-six (29.3%) died: 23% due to CHF exacerbation, 5.7% from infection, 4.4% from sudden cardiac death, 3.8% from malignancy, 2.5% from malignant arrhythmias, 1.9% from renal failure, 1.3% from stroke, and 0.6% from myocardial infarction. There were only 0.68 rehospitalizations/patient/year; the most frequent cause being CHF exacerbation (16.5%). Our study demonstrates the safety and potential benefits of a supportive day care service for advanced CHF patients. Multidrug intravenous treatment, accompanied by monitoring of electrolytes, hemoglobin and cardiac rhythm, along with education and psychological support, appear to reduce morbidity in advanced CHF patients and may have contributed to the lower than expected mortality/ hospitalization rate.

  12. Detection of Janus Kinase 2 gene single point mutation in real samples with electrochemical DNA biosensor.

    Science.gov (United States)

    Topkaya, Seda Nur; Kosova, Buket; Ozsoz, Mehmet

    2014-02-15

    Janus Kinase 2 (JAK2) gene single point mutations, which have been reported to be associated with myeloproliferative disorders, are usually detected through conventional methods such as melting curve assays, allele-specific and quantitative Polymerase Chain Reactions (PCRs). Herein, an electrochemical biosensor for the detection of a Guanine (G) to Thymine (T) transversion at nucleotide position 1849 of the JAK2 gene was reported. Due to clinical importance of this mutation, easy and sensitive tests are needed to be developed. Our aim was to design a biosensor system that is capable of detecting the mutation within less than 1h with high sensitivity. For these purposes, an electrochemical sensing system was developed based on detecting hybridization. Hybridization between probe and its target and discrimination of single point mutation was investigated by monitoring guanine oxidation signals observed at +1.0 V with Differential Pulse Voltammetry (DPV) by using synthetic oligonucleotides and Polymerase Chain Reaction (PCR) amplicons. Hybridization between probe and PCR amplicons was also determined with Electrochemical Impedance Spectroscopy (EIS). We successfully detect hybridization first in synthetic samples, and ultimately in real samples involving blood samples from patients as well as additional healthy controls. The limit of detection (S/N=3) was calculated as 44 pmol of target sequence in a 40-μl reaction volume in real samples. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Automatic tracking of vessel-like structures from a single starting point.

    Science.gov (United States)

    Oliveira, Dário Augusto Borges; Leal-Taixé, Laura; Feitosa, Raul Queiroz; Rosenhahn, Bodo

    2016-01-01

    The identification of vascular networks is an important topic in the medical image analysis community. While most methods focus on single vessel tracking, the few solutions that exist for tracking complete vascular networks are usually computationally intensive and require a lot of user interaction. In this paper we present a method to track full vascular networks iteratively using a single starting point. Our approach is based on a cloud of sampling points distributed over concentric spherical layers. We also proposed a vessel model and a metric of how well a sample point fits this model. Then, we implement the network tracking as a min-cost flow problem, and propose a novel optimization scheme to iteratively track the vessel structure by inherently handling bifurcations and paths. The method was tested using both synthetic and real images. On the 9 different data-sets of synthetic blood vessels, we achieved maximum accuracies of more than 98%. We further use the synthetic data-set to analyze the sensibility of our method to parameter setting, showing the robustness of the proposed algorithm. For real images, we used coronary, carotid and pulmonary data to segment vascular structures and present the visual results. Still for real images, we present numerical and visual results for networks of nerve fibers in the olfactory system. Further visual results also show the potential of our approach for identifying vascular networks topologies. The presented method delivers good results for the several different datasets tested and have potential for segmenting vessel-like structures. Also, the topology information, inherently extracted, can be used for further analysis to computed aided diagnosis and surgical planning. Finally, the method's modular aspect holds potential for problem-oriented adjustments and improvements. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Real-Time Single Frequency Precise Point Positioning Using SBAS Corrections

    Directory of Open Access Journals (Sweden)

    Liang Li

    2016-08-01

    Full Text Available Real-time single frequency precise point positioning (PPP is a promising technique for high-precision navigation with sub-meter or even centimeter-level accuracy because of its convenience and low cost. The navigation performance of single frequency PPP heavily depends on the real-time availability and quality of correction products for satellite orbits and satellite clocks. Satellite-based augmentation system (SBAS provides the correction products in real-time, but they are intended to be used for wide area differential positioning at 1 meter level precision. By imposing the constraints for ionosphere error, we have developed a real-time single frequency PPP method by sufficiently utilizing SBAS correction products. The proposed PPP method are tested with static and kinematic data, respectively. The static experimental results show that the position accuracy of the proposed PPP method can reach decimeter level, and achieve an improvement of at least 30% when compared with the traditional SBAS method. The positioning convergence of the proposed PPP method can be achieved in 636 epochs at most in static mode. In the kinematic experiment, the position accuracy of the proposed PPP method can be improved by at least 20 cm relative to the SBAS method. Furthermore, it has revealed that the proposed PPP method can achieve decimeter level convergence within 500 s in the kinematic mode.

  15. Technical Failure of MR Elastography Examinations of the Liver: Experience from a Large Single-Center Study.

    Science.gov (United States)

    Wagner, Mathilde; Corcuera-Solano, Idoia; Lo, Grace; Esses, Steven; Liao, Joseph; Besa, Cecilia; Chen, Nelson; Abraham, Ginu; Fung, Maggie; Babb, James S; Ehman, Richard L; Taouli, Bachir

    2017-08-01

    Purpose To assess the determinants of technical failure of magnetic resonance (MR) elastography of the liver in a large single-center study. Materials and Methods This retrospective study was approved by the institutional review board. Seven hundred eighty-one MR elastography examinations performed in 691 consecutive patients (mean age, 58 years; male patients, 434 [62.8%]) in a single center between June 2013 and August 2014 were retrospectively evaluated. MR elastography was performed at 3.0 T (n = 443) or 1.5 T (n = 338) by using a gradient-recalled-echo pulse sequence. MR elastography and anatomic image analysis were performed by two observers. Additional observers measured liver T2* and fat fraction. Technical failure was defined as no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. Logistic regression analysis was performed to assess potential predictive factors of technical failure of MR elastography. Results The technical failure rate of MR elastography at 1.5 T was 3.5% (12 of 338), while it was higher, 15.3% (68 of 443), at 3.0 T. On the basis of univariate analysis, body mass index, liver iron deposition, massive ascites, use of 3.0 T, presence of cirrhosis, and alcoholic liver disease were all significantly associated with failure of MR elastography (P analysis, only body mass index, liver iron deposition, massive ascites, and use of 3.0 T were significantly associated with failure of MR elastography (P technical failure rate of MR elastography with a gradient-recalled-echo pulse sequence was low at 1.5 T but substantially higher at 3.0 T. Massive ascites, iron deposition, and high body mass index were additional independent factors associated with failure of MR elastography of the liver with a two-dimensional gradient-recalled-echo pulse sequence. © RSNA, 2017.

  16. From single point of measurement to distributed sensing in long-term glacier monitoring

    International Nuclear Information System (INIS)

    Cesarini, Daniel; Avvenuti, Marco; Jelicic, Vana; Bilas, Vedran

    2013-01-01

    Glacial environment monitoring is a key task in understanding natural phenomena related to global warming. For the last 30 years, Automatic Weather Stations (AWSs) have been spreading among the meteorological and geophysical community, and are on the way to become a de facto standard to perform long-lasting unattended data acquisitions in single localized points of interest. Sensor Networks (SNs), on the other hand, promise the possibility to perform measurements with a higher spatial density and lower cost. Designing and developing a SN for glacial environment face particular challenges for embedded electronics and sensor systems, which is why SNs are still under research and development in this field. This paper surveys the AWSs and SNs for glacial monitoring applications and compares their characteristics.

  17. Simulation study based on the single-point temperature monitoring system of LabVIEW

    Science.gov (United States)

    Wu, Yongling; Yang, Na; Liu, Shuping; Pan, Xiaohui; Wang, Wenjiang

    2014-12-01

    This paper takes LabVIEW2012 as a development platform, creating a J-type thermocouple sensor and the NI USB-6229 data acquisition card and other hardware emulation circuitry which combined with the PC designed a single-point temperature monitoring system. Through simulation experiments, the system has a collection interval, the sampling rate per channel sampling on the temperature limit set by the user function and it also has the function of real-time display the current temperature, the temperature limit alarm, maximum temperature, minimum temperature display and a temperature history data query. This system can be used for temperature monitoring of life, research, industrial control, environmental monitoring, biomedical, tobacco processing, greenhouse cultivation, livestock breeding and other fields, which has important significance and practical value.

  18. A single quantum dot-based biosensor for DNA point mutation assay.

    Science.gov (United States)

    Tang, Wei; Zhu, Guichi; Liang, Li; Zhang, Chun-Yang

    2015-09-07

    Sensitive and selective detection of point mutation is essential to molecular biology research and early clinical diagnosis. Here, we demonstrate a single quantum dot (QD)-based biosensor for DNA point mutation assay. In this assay, a mutant target (G/C) remains unchanged after the endonuclease treatment, and the polymerase chain reaction (PCR) may be initiated with the assistance of primers and polymerase, generating a large number of mutant targets. The amplified mutant targets can be captured by biotinylated probes during the process of denaturation and annealing, and Cy5-dGTP may be assembled into the biotinylated probe with the catalysis of polymerase, leading to the formation of Cy5-labeled biotinylated probes. The Cy5-labeled biotinylated probes can be further assembled onto the QD surface to obtain a Cy5-DNA-QD complex, resulting in the generation of fluorescence resonance energy transfer (FRET) between the QD donor and the Cy5 receptor. The mutant targets can be quantitatively evaluated by the measurement of Cy5 counts by total internal reflection fluorescence (TIRF) microscopy. While in the presence of wild-type targets (T/A), no Cy5-dGTP can be assembled into the biotinylated probe due to the presence of a mismatch and consequently no FRET is observed. This single QD-based biosensor exhibits high sensitivity with a detection limit of 5.3 aM (or 32 copies) and can even discriminate as low as 0.01% variant frequency from the mixture of mutant targets and wild-type ones. Importantly, this biosensor can be used for genomic analysis in human lung cancer cells, and may be further applied for an early clinical diagnosis and personalized medicine.

  19. Monitoring single event upsets in SRAM-based FPGAs at the SuperKEKB interaction point

    Science.gov (United States)

    Giordano, R.; Tortone, G.; Perrella, S.; Izzo, V.; Aloisio, A.

    2017-07-01

    In February 2016, the SuperKEKB positron-electron high-luminosity collider of the KEK laboratory (Tsukuba, Japan) started being commissioned. A dedicated commissioning detector, named BEAST2, has been used to characterize beam backgrounds before the Belle2 detector was rolled into the beams and to provide tuning parameters for Monte Carlo simulations. BEAST2 consists of a fiberglass support structure and several sub-detectors mounted onto it, including time projection chambers (TPCs) and He-3 tubes. In this work, we present direct measurements of radiation-induced single event upsets in a SRAM-based FPGA device installed in BEAST2 at a distance of ~ 1 m from the beam interaction point. Our goal was to provide experimental results of the expected radiation-induced configuration upset rate and power consumption variation at Belle2 and at other experiments operating in similar radiation environments. Beam currents for both electron and positron rings spanned a range between 50 and 500 mA, therefore providing data about the FPGA operation in different radiation conditions. Even if the machine has not been providing collisions yet, as the beams were not focused to the interaction point, our results show a rate of 0.15 upsets/day averaged over the whole commissioning time frame. We had neither evidence of total dose effects on the FPGA power consumption nor of permanent damage to the device.

  20. Spherical Projection Based Straight Line Segment Extraction for Single Station Terrestrial Laser Point Cloud

    Directory of Open Access Journals (Sweden)

    ZHANG Fan

    2015-06-01

    Full Text Available Due to the discrete distribution computing errors and lack of adaptability are ubiquitous in the current straight line extraction for TLS data methods. A 3D straight line segment extraction method is proposed based on spherical projection for single station terrestrial laser point clouds. Firstly, horizontal and vertical angles of each laser point are calculated by means of spherical coordinates, intensity panoramic image according to the two angles is generated. Secondly, edges which include straight line features are detected from intensity panoramic image by using of edge detection algorithm. Thirdly, great circles are detected from edges of panoramic image using spherical Hough transform. According to the axiom that a straight line segment in 3D space is a spherical great circle after spherical projection, detecting great circles from spherical projected data sets is essentially detecting straight line segments from 3D data sets without spherical projection. Finally, a robust 3D straight line fitting method is employed to fitting the straight lines and calculating parameters of the straight line segments. Experiments using different data sets and comparison with other methods show the accuracy and applicability of the proposed method.

  1. Sensor system for multi-point monitoring using bending loss of single mode optical fiber

    International Nuclear Information System (INIS)

    Kim, Heon Young; Kim, Dae Hyun

    2015-01-01

    Applications of smart sensors have been extended to safety systems in the aerospace, transportation and civil engineering fields. In particular, structural health monitoring techniques using smart sensors have gradually become necessary and have been developed to prevent dangers to human life and damage to assets. Generally, smart sensors are based on electro-magnets and have several weaknesses, including electro-magnetic interference and distortion. Therefore, fiber optic sensors are an outstanding alternative to overcome the weaknesses of electro-magnetic sensors. However, they require expensive devices and complex systems. This paper proposes a new, affordable and simple sensor system that uses a single fiber to monitor pressures at multiple-points. Moreover, a prototype of the sensor system was manufactured and tested for a feasibility study. Based on the results of this experimental test, a relationship was carefully observed between the bend loss conditions and light-intensity. As a result, it was shown that impacts at multiple-points could be monitored.

  2. Analysis of Point Based Image Registration Errors With Applications in Single Molecule Microscopy.

    Science.gov (United States)

    Cohen, E A K; Ober, R J

    2013-12-15

    We present an asymptotic treatment of errors involved in point-based image registration where control point (CP) localization is subject to heteroscedastic noise; a suitable model for image registration in fluorescence microscopy. Assuming an affine transform, CPs are used to solve a multivariate regression problem. With measurement errors existing for both sets of CPs this is an errors-in-variable problem and linear least squares is inappropriate; the correct method being generalized least squares. To allow for point dependent errors the equivalence of a generalized maximum likelihood and heteroscedastic generalized least squares model is achieved allowing previously published asymptotic results to be extended to image registration. For a particularly useful model of heteroscedastic noise where covariance matrices are scalar multiples of a known matrix (including the case where covariance matrices are multiples of the identity) we provide closed form solutions to estimators and derive their distribution. We consider the target registration error (TRE) and define a new measure called the localization registration error (LRE) believed to be useful, especially in microscopy registration experiments. Assuming Gaussianity of the CP localization errors, it is shown that the asymptotic distribution for the TRE and LRE are themselves Gaussian and the parameterized distributions are derived. Results are successfully applied to registration in single molecule microscopy to derive the key dependence of the TRE and LRE variance on the number of CPs and their associated photon counts. Simulations show asymptotic results are robust for low CP numbers and non-Gaussianity. The method presented here is shown to outperform GLS on real imaging data.

  3. Turn-off failure in multi-finger SOI-LIGBT used for single chip inverter ICs

    Science.gov (United States)

    Zhang, Long; Zhu, Jing; Zhao, Minna; Huang, Xuequan; Chen, Jiajun; Sun, Weifeng; Ding, Desheng

    2017-11-01

    In this paper, the clamped inductive turn-off failure of the Silicon-on-Insulator Lateral Insulated Gate Bipolar Transistor (SOI-LIGBT) with multiple fingers under high-voltage and high-current conditions is investigated. First, the measured turn-off waveforms combining with the on-state I-V characteristics of the failed device are discussed to distinguish the probable cause of the failure. Then, two-dimensional (2-D) electrothermal simulations are performed to reproduce the failure by using Sentaurus TCAD. The failure is originated from an inhomogeneous depletion behavior among the paralleled fingers during the turn-off, which gives rise to the non-uniform current-sharing and the subsequent current crowding in single finger. As a result, the latch-up of the device takes place. The simulation indicates that the current crowding is formed mainly through an internal path in the silicon. In order to verify the failure mechanism, an improved device with deep-oxide trenches arranged between the adjacent fingers is fabricated. The measured results demonstrate that no failure occurs when the improved device turns off under high-voltage and high-current conditions.

  4. Evaluations of Three-Dimensional Building Model Reconstruction from LiDAR Point Clouds and Single-View Perspective Imagery

    Directory of Open Access Journals (Sweden)

    F. Tsai

    2014-06-01

    Full Text Available This paper briefly presents two approaches for effective three-dimensional (3D building model reconstruction from terrestrial laser scanning (TLS data and single perspective view imagery and assesses their applicability to the reconstruction of 3D models of landmark or historical buildings. The collected LiDAR point clouds are registered based on conjugate points identified using a seven-parameter transformation system. Three dimensional models are generated using plan and surface fitting algorithms. The proposed single-view reconstruction (SVR method is based on vanishing points and single-view metrology. More detailed models can also be generated according to semantic analysis of the façade images. Experimental results presented in this paper demonstrate that both TLS and SVR approaches can successfully produce accurate and detailed 3D building models from LiDAR point clouds or different types of single-view perspective images.

  5. Multi-spectral investigation of bulk and facet failures in high-power single emitters at 980 nm

    Science.gov (United States)

    Yanson, Dan; Levy, Moshe; Shamay, Moshe; Cohen, Shalom; Shkedy, Lior; Berk, Yuri; Tessler, Renana; Klumel, Genadi; Rappaport, Noam; Karni, Yoram

    2013-03-01

    Reliable single emitters delivering >10W in the 9xx nm spectral range, are common building blocks for fiber laser pumps. As facet passivation techniques can suppress or delay catastrophic optical mirror damage (COMD) extending emitter reliability into hundreds of thousands of hours, other, less dominant, failure modes such as intra-chip catastrophic optical bulk damage (COBD) become apparent. Based on our failure statistics in high current operation, only ~52% of all failures can be attributed to COMD. Imaging through a window opened in the metallization on the substrate (n) side of a p-side down mounted emitter provides valuable insight into both COMD and COBD failure mechanisms. We developed a laser ablation process to define a window on the n-side of an InGaAs/AlGaAs 980nm single emitter that is overlaid on the pumped 90μm stripe on the p-side. The ablation process is compatible with the chip wire-bonding, enabling the device to be operated at high currents with high injection uniformity. We analyzed both COMD and COBD failed emitters in the electroluminescence and mid-IR domains supported by FIB/SEM observation. The ablated devices revealed branching dark line patterns, with a line origin either at the facet center (COMD case) or near the stripe edge away from the facet (COBD case). In both cases, the branching direction is always toward the rear facet (against the photon density gradient), with SEM images revealing a disordered active layer structure. Absorption levels between 0.22eV - 0.55eV were observed in disordered regions by FT-IR spectroscopy. Temperature mapping of a single emitter in the MWIR domain was performed using an InSb detector. We also report an electroluminescence study of a single emitter just before and after failure.

  6. Towards single-valued polylogarithms in two variables for the seven-point remainder function in multi-Regge kinematics

    Directory of Open Access Journals (Sweden)

    Johannes Broedel

    2017-02-01

    Full Text Available We investigate single-valued polylogarithms in two complex variables, which are relevant for the seven-point remainder function in N=4 super-Yang–Mills theory in the multi-Regge regime. After constructing these two-dimensional polylogarithms, we determine the leading logarithmic approximation of the seven-point remainder function up to and including five loops.

  7. Femtosecond few- to single-electron point-projection microscopy for nanoscale dynamic imaging

    Science.gov (United States)

    Bainbridge, A. R.; Barlow Myers, C. W.; Bryan, W. A.

    2016-01-01

    Femtosecond electron microscopy produces real-space images of matter in a series of ultrafast snapshots. Pulses of electrons self-disperse under space-charge broadening, so without compression, the ideal operation mode is a single electron per pulse. Here, we demonstrate femtosecond single-electron point projection microscopy (fs-ePPM) in a laser-pump fs-e-probe configuration. The electrons have an energy of only 150 eV and take tens of picoseconds to propagate to the object under study. Nonetheless, we achieve a temporal resolution with a standard deviation of 114 fs (equivalent to a full-width at half-maximum of 269 ± 40 fs) combined with a spatial resolution of 100 nm, applied to a localized region of charge at the apex of a nanoscale metal tip induced by 30 fs 800 nm laser pulses at 50 kHz. These observations demonstrate real-space imaging of reversible processes, such as tracking charge distributions, is feasible whilst maintaining femtosecond resolution. Our findings could find application as a characterization method, which, depending on geometry, could resolve tens of femtoseconds and tens of nanometres. Dynamically imaging electric and magnetic fields and charge distributions on sub-micron length scales opens new avenues of ultrafast dynamics. Furthermore, through the use of active compression, such pulses are an ideal seed for few-femtosecond to attosecond imaging applications which will access sub-optical cycle processes in nanoplasmonics. PMID:27158637

  8. Femtosecond few- to single-electron point-projection microscopy for nanoscale dynamic imaging

    Directory of Open Access Journals (Sweden)

    A. R. Bainbridge

    2016-03-01

    Full Text Available Femtosecond electron microscopy produces real-space images of matter in a series of ultrafast snapshots. Pulses of electrons self-disperse under space-charge broadening, so without compression, the ideal operation mode is a single electron per pulse. Here, we demonstrate femtosecond single-electron point projection microscopy (fs-ePPM in a laser-pump fs-e-probe configuration. The electrons have an energy of only 150 eV and take tens of picoseconds to propagate to the object under study. Nonetheless, we achieve a temporal resolution with a standard deviation of 114 fs (equivalent to a full-width at half-maximum of 269 ± 40 fs combined with a spatial resolution of 100 nm, applied to a localized region of charge at the apex of a nanoscale metal tip induced by 30 fs 800 nm laser pulses at 50 kHz. These observations demonstrate real-space imaging of reversible processes, such as tracking charge distributions, is feasible whilst maintaining femtosecond resolution. Our findings could find application as a characterization method, which, depending on geometry, could resolve tens of femtoseconds and tens of nanometres. Dynamically imaging electric and magnetic fields and charge distributions on sub-micron length scales opens new avenues of ultrafast dynamics. Furthermore, through the use of active compression, such pulses are an ideal seed for few-femtosecond to attosecond imaging applications which will access sub-optical cycle processes in nanoplasmonics.

  9. Obtaining Global Picture From Single Point Observations by Combining Data Assimilation and Machine Learning Tools

    Science.gov (United States)

    Shprits, Y.; Zhelavskaya, I. S.; Kellerman, A. C.; Spasojevic, M.; Kondrashov, D. A.; Ghil, M.; Aseev, N.; Castillo Tibocha, A. M.; Cervantes Villa, J. S.; Kletzing, C.; Kurth, W. S.

    2017-12-01

    Increasing volume of satellite measurements requires deployment of new tools that can utilize such vast amount of data. Satellite measurements are usually limited to a single location in space, which complicates the data analysis geared towards reproducing the global state of the space environment. In this study we show how measurements can be combined by means of data assimilation and how machine learning can help analyze large amounts of data and can help develop global models that are trained on single point measurement. Data Assimilation: Manual analysis of the satellite measurements is a challenging task, while automated analysis is complicated by the fact that measurements are given at various locations in space, have different instrumental errors, and often vary by orders of magnitude. We show results of the long term reanalysis of radiation belt measurements along with fully operational real-time predictions using data assimilative VERB code. Machine Learning: We present application of the machine learning tools for the analysis of NASA Van Allen Probes upper-hybrid frequency measurements. Using the obtained data set we train a new global predictive neural network. The results for the Van Allen Probes based neural network are compared with historical IMAGE satellite observations. We also show examples of predictions of geomagnetic indices using neural networks. Combination of machine learning and data assimilation: We discuss how data assimilation tools and machine learning tools can be combine so that physics-based insight into the dynamics of the particular system can be combined with empirical knowledge of it's non-linear behavior.

  10. Is equilibrium point control feasible for fast goal-directed single-joint movements?

    Science.gov (United States)

    Kistemaker, Dinant A; Van Soest, Arthur J; Bobbert, Maarten F

    2006-05-01

    Several types of equilibrium point (EP) controllers have been proposed for the control of posture and movement. EP controllers are appealing from a computational perspective because they do not require solving the "inverse dynamic problem" (i.e., computation of the torques required to move a system along a desired trajectory). It has been argued that EP controllers are not capable of controlling fast single-joint movements. To refute this statement, several extensions have been proposed, although these have been tested using models in which only the tendon compliance, force-length-velocity relation, and mechanical interaction between tendon and contractile element were not adequately represented. In the present study, fast elbow-joint movements were measured and an attempt was made to reproduce these using a realistic musculoskeletal model of the human arm. Three types of EP controllers were evaluated: an open-loop alpha-controller, a closed-loop lambda-controller, and a hybrid open- and closed-loop controller. For each controller we considered a continuous version and a version in which the control signals were sent out intermittently. Only the intermittent hybrid EP controller was capable of generating movements that were as fast as those of the subjects. As a result of the nonlinear muscle properties, the hybrid EP controller requires a more detailed representation of static muscle properties than generally assumed in the context of EP control. In sum, this study shows that fast single-joint movements can be realized without explicitly solving the inverse dynamics problem, but in a less straightforward manner than implied by proponents of conventional EP controllers.

  11. Management of Pediatric Acute Liver Failure in a Region With Insufficient Deceased Donor Support: A Single-Center Experience.

    Science.gov (United States)

    Yankol, Yucel; Ertugrul, Mustafa; Kanmaz, Turan; Mecit, Nesimi; Ocak, Ilhan; Durmaz, Ozlem; Acarli, Koray; Kalayoglu, Munci

    2016-10-01

    Acute liver failure is a rapidly progressive and life-threatening disease in children, whose clinical features differ from those of adults. This is a review of a single center's experience with pediatric acute liver failure in a region with insufficient deceased donor support. The study is a retrospective review and analysis of 22 pediatric patients with acute liver failure between January 2007 and May 2013. The cause of acute liver failure was indeterminate in 45.4% of cases. Listing for liver transplant was required in 72.7% of patients, whereas 27.3% developed spontaneous remission. In the patients placed on the liver transplant wait list, 75% underwent liver transplant and 25% died before undergoing liver transplant. The presence of ascites, high-grade encephalopathy, and laboratory findings including high lactate dehydrogenase and phosphorous levels and international normalized ratio were significant parameters in selecting patients needing liver transplants. All liver transplants were from living donors. One- and 3-year patient survival rates after liver transplant were 75% and 75%. No serious donor complications occurred. Living-donor liver transplant may be the only option to save the lives of pediatric patients with acute liver failure, especially in regions with insufficient deceased-donor support. Timely referral to a multidisciplinary transplant center, expedient evaluation of living donors, and appropriate timing of transplant are crucial for a successful outcome.

  12. Prediction and control of pillow defect in single point incremental forming using numerical simulations

    Energy Technology Data Exchange (ETDEWEB)

    Isidore, B. B. Lemopi [Eastern Mediterranean University, Gazimagusa (Turkmenistan); Hussain, G.; Khan, Wasim A. [GIK Institute of Engineering, Swabi (Pakistan); Shamachi, S. Pourhassan [University of Minho, Guimaraes (Portugal)

    2016-05-15

    Pillows formed at the center of sheets in Single point incremental forming (SPIF) are fabrication defects which adversely affect the geometrical accuracy and formability of manufactured parts. This study is focused on using FEA as a tool to predict and control pillowing in SPIF by varying tool size and shape. 3D Finite element analysis (FEA) and experiments are carried out using annealed Aluminum 1050. From FEA, it is found out that the stress/strain state in the immediate vicinity of the forming tool in the transverse direction plays a determinant role on sheet pillowing. Furthermore, pillow height increases as compression in the sheet-plane increases. The nature of in-plane stresses in the transverse direction varies from compressive to tensile as the tool-end geometry is changed from spherical to flat. Additionally, the magnitude of corresponding in-plane stresses decreases as the tool radius increases. According to measurements from the FEA model, flat end tools and large radii both retard pillow formation. However, the influence of changing tool end shape from hemispherical to flat is observed to be more important than the effect of varying tool radius, because the deformation zone remains in tension in the transverse direction while forming with flat end tools. These findings are verified by conducting a set of experiments. A fair agreement between the FEM and empirical results show that FEM can be employed as a tool to predict and control the pillow defect in SPIF.

  13. Pan European Phenological database (PEP725): a single point of access for European data

    Science.gov (United States)

    Templ, Barbara; Koch, Elisabeth; Bolmgren, Kjell; Ungersböck, Markus; Paul, Anita; Scheifinger, Helfried; Rutishauser, This; Busto, Montserrat; Chmielewski, Frank-M.; Hájková, Lenka; Hodzić, Sabina; Kaspar, Frank; Pietragalla, Barbara; Romero-Fresneda, Ramiro; Tolvanen, Anne; Vučetič, Višnja; Zimmermann, Kirsten; Zust, Ana

    2018-02-01

    The Pan European Phenology (PEP) project is a European infrastructure to promote and facilitate phenological research, education, and environmental monitoring. The main objective is to maintain and develop a Pan European Phenological database (PEP725) with an open, unrestricted data access for science and education. PEP725 is the successor of the database developed through the COST action 725 "Establishing a European phenological data platform for climatological applications" working as a single access point for European-wide plant phenological data. So far, 32 European meteorological services and project partners from across Europe have joined and supplied data collected by volunteers from 1868 to the present for the PEP725 database. Most of the partners actively provide data on a regular basis. The database presently holds almost 12 million records, about 46 growing stages and 265 plant species (including cultivars), and can be accessed via http://www.pep725.eu/. Users of the PEP725 database have studied a diversity of topics ranging from climate change impact, plant physiological question, phenological modeling, and remote sensing of vegetation to ecosystem productivity.

  14. Pan European Phenological database (PEP725): a single point of access for European data.

    Science.gov (United States)

    Templ, Barbara; Koch, Elisabeth; Bolmgren, Kjell; Ungersböck, Markus; Paul, Anita; Scheifinger, Helfried; Rutishauser, This; Busto, Montserrat; Chmielewski, Frank-M; Hájková, Lenka; Hodzić, Sabina; Kaspar, Frank; Pietragalla, Barbara; Romero-Fresneda, Ramiro; Tolvanen, Anne; Vučetič, Višnja; Zimmermann, Kirsten; Zust, Ana

    2018-02-18

    The Pan European Phenology (PEP) project is a European infrastructure to promote and facilitate phenological research, education, and environmental monitoring. The main objective is to maintain and develop a Pan European Phenological database (PEP725) with an open, unrestricted data access for science and education. PEP725 is the successor of the database developed through the COST action 725 "Establishing a European phenological data platform for climatological applications" working as a single access point for European-wide plant phenological data. So far, 32 European meteorological services and project partners from across Europe have joined and supplied data collected by volunteers from 1868 to the present for the PEP725 database. Most of the partners actively provide data on a regular basis. The database presently holds almost 12 million records, about 46 growing stages and 265 plant species (including cultivars), and can be accessed via http://www.pep725.eu/ . Users of the PEP725 database have studied a diversity of topics ranging from climate change impact, plant physiological question, phenological modeling, and remote sensing of vegetation to ecosystem productivity.

  15. An application of eddy current damping effect on single point diamond turning of titanium alloys

    Science.gov (United States)

    Yip, W. S.; To, S.

    2017-11-01

    Titanium alloys Ti6Al4V (TC4) have been popularly applied in many industries. They have superior material properties including an excellent strength-to-weight ratio and corrosion resistance. However, they are regarded as difficult to cut materials; serious tool wear, a high level of cutting vibration and low surface integrity are always involved in machining processes especially in ultra-precision machining (UPM). In this paper, a novel hybrid machining technology using an eddy current damping effect is firstly introduced in UPM to suppress machining vibration and improve the machining performance of titanium alloys. A magnetic field was superimposed on samples during single point diamond turning (SPDT) by exposing the samples in between two permanent magnets. When the titanium alloys were rotated within a magnetic field in the SPDT, an eddy current was generated through a stationary magnetic field inside the titanium alloys. An eddy current generated its own magnetic field with the opposite direction of the external magnetic field leading a repulsive force, compensating for the machining vibration induced by the turning process. The experimental results showed a remarkable improvement in cutting force variation, a significant reduction in adhesive tool wear and an extreme long chip formation in comparison to normal SPDT of titanium alloys, suggesting the enhancement of the machinability of titanium alloys using an eddy current damping effect. An eddy current damping effect was firstly introduced in the area of UPM to deliver the results of outstanding machining performance.

  16. An application of eddy current damping effect on single point diamond turning of titanium alloys

    International Nuclear Information System (INIS)

    Yip, W S; To, S

    2017-01-01

    Titanium alloys Ti6Al4V (TC4) have been popularly applied in many industries. They have superior material properties including an excellent strength-to-weight ratio and corrosion resistance. However, they are regarded as difficult to cut materials; serious tool wear, a high level of cutting vibration and low surface integrity are always involved in machining processes especially in ultra-precision machining (UPM). In this paper, a novel hybrid machining technology using an eddy current damping effect is firstly introduced in UPM to suppress machining vibration and improve the machining performance of titanium alloys. A magnetic field was superimposed on samples during single point diamond turning (SPDT) by exposing the samples in between two permanent magnets. When the titanium alloys were rotated within a magnetic field in the SPDT, an eddy current was generated through a stationary magnetic field inside the titanium alloys. An eddy current generated its own magnetic field with the opposite direction of the external magnetic field leading a repulsive force, compensating for the machining vibration induced by the turning process. The experimental results showed a remarkable improvement in cutting force variation, a significant reduction in adhesive tool wear and an extreme long chip formation in comparison to normal SPDT of titanium alloys, suggesting the enhancement of the machinability of titanium alloys using an eddy current damping effect. An eddy current damping effect was firstly introduced in the area of UPM to deliver the results of outstanding machining performance. (paper)

  17. Mental Health Conditions and Symptoms in Pediatric Hospitalizations: A Single-Center Point Prevalence Study.

    Science.gov (United States)

    Doupnik, Stephanie K; Henry, M Katherine; Bae, Hanah; Litman, Jessica; Turner, Shanarra; Scharko, Alexander M; Feudtner, Chris

    2017-03-01

    Children and adolescents necessitating hospitalization for physical health conditions are at high risk for mental health conditions; however, the prevalence of mental health conditions and symptoms among hospitalized children and adolescents is uncertain. The objective of this study was to determine the proportion of hospitalized children and adolescents who have diagnosed mental health disorders or undiagnosed mental health problems. In this single-center point prevalence study of hospitalized children between the ages of 4 and 21 years, patients or their parents reported known mental health diagnoses and use of services using the Services Assessment for Children and Adolescent, and they reported patient mental health symptoms using the Pediatric Symptom Checklist, 17-item form (PSC-17). Of 229 eligible patients, 119 agreed to participate. Demographic characteristics of patients who enrolled were not statistically significantly different from those of patients who declined to participate. Among participants, 26% (95% confidence interval [CI], 18%-35%) reported a known mental health diagnosis. On the PSC-17, 29% (95% CI, 21%-38%) of participants had a positive screen for mental health symptoms. Of those with a positive screen, 38% (95% CI, 21%-55%) had no known mental health diagnosis, and 26% (95% CI, 12%-43%) had not received ambulatory mental health services in the 12 months before hospitalization. Mental health conditions and symptoms are common among patients hospitalized in a tertiary children's hospital, and many affected patients are not receiving ambulatory mental health services. Copyright © 2016 Academic Pediatric Association. Published by Elsevier Inc. All rights reserved.

  18. Estimating Uncertainty of Point-Cloud Based Single-Tree Segmentation with Ensemble Based Filtering

    Directory of Open Access Journals (Sweden)

    Matthew Parkan

    2018-02-01

    Full Text Available Individual tree crown segmentation from Airborne Laser Scanning data is a nodal problem in forest remote sensing. Focusing on single layered spruce and fir dominated coniferous forests, this article addresses the problem of directly estimating 3D segment shape uncertainty (i.e., without field/reference surveys, using a probabilistic approach. First, a coarse segmentation (marker controlled watershed is applied. Then, the 3D alpha hull and several descriptors are computed for each segment. Based on these descriptors, the alpha hulls are grouped to form ensembles (i.e., groups of similar tree shapes. By examining how frequently regions of a shape occur within an ensemble, it is possible to assign a shape probability to each point within a segment. The shape probability can subsequently be thresholded to obtain improved (filtered tree segments. Results indicate this approach can be used to produce segmentation reliability maps. A comparison to manually segmented tree crowns also indicates that the approach is able to produce more reliable tree shapes than the initial (unfiltered segmentation.

  19. Single point incremental sheet forming investigated by in-process 3D digital image correlation

    Directory of Open Access Journals (Sweden)

    Bernhart G.

    2010-06-01

    Full Text Available Single Point Incremental Forming (SPIF is a promising sheet metal forming process for prototyping and small batches, in which the blank is formed in a stepwise fashion by a displacement-controlled small-sized tool. Due to specific strain paths induced by the process and limited plastic zones in the contact region between the tool and the workpiece, forming diagrams and forming strategies are different from the classical stamping processes. One major limitation of SPIF is the lack of accuracy of the obtained final parts because of the poor knowledge of the state of stress during the process that requires a good description of the material models and a right choice of the process parameters. In this paper, the SPIF process is experimentally investigated by the mean of surface 3D digital image correlation during the forming of a AW-5086-H111 grade aluminium alloy. Development of strain fields encountered in incremental forming is reported and material formability is evaluated on several formed shapes, taking into account a wide range of straining conditions of this process.

  20. Single point incremental sheet forming investigated by in-process 3D digital image correlation

    Science.gov (United States)

    Decultot, N.; Robert, L.; Velay, V.; Bernhart, G.

    2010-06-01

    Single Point Incremental Forming (SPIF) is a promising sheet metal forming process for prototyping and small batches, in which the blank is formed in a stepwise fashion by a displacement-controlled small-sized tool. Due to specific strain paths induced by the process and limited plastic zones in the contact region between the tool and the workpiece, forming diagrams and forming strategies are different from the classical stamping processes. One major limitation of SPIF is the lack of accuracy of the obtained final parts because of the poor knowledge of the state of stress during the process that requires a good description of the material models and a right choice of the process parameters. In this paper, the SPIF process is experimentally investigated by the mean of surface 3D digital image correlation during the forming of a AW-5086-H111 grade aluminium alloy. Development of strain fields encountered in incremental forming is reported and material formability is evaluated on several formed shapes, taking into account a wide range of straining conditions of this process.

  1. Prediction and control of pillow defect in single point incremental forming using numerical simulations

    International Nuclear Information System (INIS)

    Isidore, B. B. Lemopi; Hussain, G.; Khan, Wasim A.; Shamachi, S. Pourhassan

    2016-01-01

    Pillows formed at the center of sheets in Single point incremental forming (SPIF) are fabrication defects which adversely affect the geometrical accuracy and formability of manufactured parts. This study is focused on using FEA as a tool to predict and control pillowing in SPIF by varying tool size and shape. 3D Finite element analysis (FEA) and experiments are carried out using annealed Aluminum 1050. From FEA, it is found out that the stress/strain state in the immediate vicinity of the forming tool in the transverse direction plays a determinant role on sheet pillowing. Furthermore, pillow height increases as compression in the sheet-plane increases. The nature of in-plane stresses in the transverse direction varies from compressive to tensile as the tool-end geometry is changed from spherical to flat. Additionally, the magnitude of corresponding in-plane stresses decreases as the tool radius increases. According to measurements from the FEA model, flat end tools and large radii both retard pillow formation. However, the influence of changing tool end shape from hemispherical to flat is observed to be more important than the effect of varying tool radius, because the deformation zone remains in tension in the transverse direction while forming with flat end tools. These findings are verified by conducting a set of experiments. A fair agreement between the FEM and empirical results show that FEM can be employed as a tool to predict and control the pillow defect in SPIF.

  2. The use of single point incremental forming for customized implants of unicondylar knee arthroplasty: a review

    Directory of Open Access Journals (Sweden)

    Pankaj Kailasrao Bhoyar

    Full Text Available Abstract Introduction The implantable devices are having enormous market. These products are basically made by traditional manufacturing process, but for the custom-made implants Incremental Sheet Forming is a paramount alternative. Single Point Incremental Forming (SPIF is a manufacturing process to form intricate, asymmetrical components. It forms the component using stretching and bending by maintaining materials crystal structure. SPIF process can be performed using conventional Computer Numerical Control (CNC milling machine. Review This review paper elaborates the various manufacturing processes carried on various biocompatible metallic and nonmetallic customised implantable devices. Conclusion Ti-6Al-4V alloy is broadly used for biomedical implants, but in this alloy, Vanadium is toxic so this alloy is not compatible for implants. The attention of researchers is towards the non toxic and suitable biocompatible materials. For this reason, a novel approach was developed in order to enhance the mechanical properties of this material. . The development of incremental forming technique can improve the formability of existing alloys and may meet the current strict requirements for performance of dies and punches.

  3. Modeling and optimization of surface roughness in single point incremental forming process

    Directory of Open Access Journals (Sweden)

    Suresh Kurra

    2015-07-01

    Full Text Available Single point incremental forming (SPIF is a novel and potential process for sheet metal prototyping and low volume production applications. This article is focuses on the development of predictive models for surface roughness estimation in SPIF process. Surface roughness in SPIF has been modeled using three different techniques namely, Artificial Neural Networks (ANN, Support Vector Regression (SVR and Genetic Programming (GP. In the development of these predictive models, tool diameter, step depth, wall angle, feed rate and lubricant type have been considered as model variables. Arithmetic mean surface roughness (Ra and maximum peak to valley height (Rz are used as response variables to assess the surface roughness of incrementally formed parts. The data required to generate, compare and evaluate the proposed models have been obtained from SPIF experiments performed on Computer Numerical Control (CNC milling machine using Box–Behnken design. The developed models are having satisfactory goodness of fit in predicting the surface roughness. Further, the GP model has been used for optimization of Ra and Rz using genetic algorithm. The optimum process parameters for minimum surface roughness in SPIF have been obtained and validated with the experiments and found highly satisfactory results within 10% error.

  4. Readout of a single electron spin in a double quantum dot using a quantum point contact

    International Nuclear Information System (INIS)

    Zhang Jianping; Ouyang Shihua; You, J Q; Lam, C.-H.

    2008-01-01

    We study the dynamics of a single electron spin in a double quantum dot (DQD) and its readout via a quantum point contact (QPC). We model the system microscopically and derive rate equations for the reduced electron density matrix of the DQD. Two cases with one and two electrons in the DQD are studied. In the one-electron case, with different Zeeman splittings in the two dots, the electron spin states are distinctly characterized by a constant and an oscillatory current through the QPC. In the two-electron case, the readout of the spin state of the electron in one of the dots called the qubit dot is essentially similar after considering hyperfine interactions between the electrons and the nuclear spins of the host materials and a uniform magnetic field applied to the DQD. Moreover, to ensure that an electron is properly injected into the qubit dot, we propose to determine the success of the electron injection from the variations of the QPC current after applying an oscillating magnetic field to the qubit dot

  5. A geometric approach for fault detection and isolation of stator short circuit failure in a single asynchronous machine

    KAUST Repository

    Khelouat, Samir

    2012-06-01

    This paper deals with the problem of detection and isolation of stator short-circuit failure in a single asynchronous machine using a geometric approach. After recalling the basis of the geometric approach for fault detection and isolation in nonlinear systems, we will study some structural properties which are fault detectability and isolation fault filter existence. We will then design filters for residual generation. We will consider two approaches: a two-filters structure and a single filter structure, both aiming at generating residuals which are sensitive to one fault and insensitive to the other faults. Some numerical tests will be presented to illustrate the efficiency of the method.

  6. Retrospective Analysis of Factors Leading to Pediatric Tracheostomy Decannulation Failure. A Single-Institution Experience.

    Science.gov (United States)

    Bandyopadhyay, Anuja; Cristea, A Ioana; Davis, Stephanie D; Ackerman, Veda L; Slaven, James E; Jalou, Hasnaa E; Givan, Deborah C; Daftary, Ameet

    2017-01-01

    There is a lack of evidence regarding factors associated with failure of tracheostomy decannulation. We aimed to identify characteristics of pediatric patients who fail a tracheostomy decannulation challenge Methods: A retrospective review was performed on all patients who had a decannulation challenge at a tertiary care center from June 2006 to October 2013. Tracheostomy decannulation failure was defined as reinsertion of the tracheostomy tube within 6 months of the challenge. Data on demographics, indications for tracheostomy, home mechanical ventilation, and comorbidities were collected. Data were also collected on specific airway endoscopic findings during the predecannulation bronchoscopy and airway surgical procedures before decannulation. We attempted to predict the decannulation outcome by analyzing associations. 147 of 189 (77.8%) patients were successfully decannulated on the first attempt. Tracheostomy performed due to chronic respiratory failure decreased odds for decannulation failure (odds ratio = 0.34, 95% confidence interval = 0.15-0.77). Genetic abnormalities (45%) and feeding dysfunction (93%) were increased in the population of patients failing their first attempt. The presence of one comorbidity increased the odds of failure by 68% (odds ratio = 1.68, 95% confidence interval = 1.23-2.29). Decannulation pursuit based on parental expectation of success, rather than medically determined readiness, was associated with a higher chance of failure (P = 0.01). Our study highlights the role of genetic abnormalities, feeding dysfunction, and multiple comorbidities in patients who fail decannulation. Our findings also demonstrate that the outcome of decannulation may be predicted by the indication for tracheostomy. Patients who had tracheostomy placed for chronic respiratory support had a higher likelihood of success. Absence of a surgically treatable airway obstruction abnormality on the predecannulation bronchoscopy increased the

  7. Papilla height in relation to the distance between bone crest and interproximal contact point at single-tooth implants: A systematic review.

    Science.gov (United States)

    Roccuzzo, Mario; Roccuzzo, Andrea; Ramanuskaite, Ausra

    2018-03-01

    The aim of this systematic review was to investigate the tooth-implant papilla formation in correlation with the distance between the interproximal bone level and the prosthetic contact point. A comprehensive search of the current literature (01/01/2000-01/01/2017) was performed to identify human trials that included 10 patients or more, with at least 12 months follow-up, in need of the replacement of one single tooth in the anterior maxillary region with an implant-supported single crown. To meet the inclusion criteria, studies had to provide both radiographic and clinical data regarding the distance between the interproximal bone level and the prosthetic contact point. The search yielded 136 records. After evaluation of abstracts and full texts, 12 papers were included in the final review, even though various reference points, for the comparison between the vertical distance and the papilla height, were used. The vertical distance between the interproximal bone level and prosthetic contact point ranged between 2 and 11 mm, and the partial or complete papilla fill (Jemt's score 2-3) ranged between 56.5% and 100% of cases. There is limited evidence that the vertical distance from the base of the interproximal contact point to the crestal bone level seems to affect the interproximal papilla height; that is, the lower is the distance the higher is the percentage of papilla fill. Complete embrasure fill between an implant restoration and the adjacent tooth seems to be correlated with the integrity of the periodontal ligament of the tooth. To reduce the risk of aesthetic failures, interproximal probing on the adjacent teeth should be encouraged before implant placement. © 2018 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  8. Detection of Single Tree Stems in Forested Areas from High Density ALS Point Clouds Using 3d Shape Descriptors

    Science.gov (United States)

    Amiri, N.; Polewski, P.; Yao, W.; Krzystek, P.; Skidmore, A. K.

    2017-09-01

    Airborne Laser Scanning (ALS) is a widespread method for forest mapping and management purposes. While common ALS techniques provide valuable information about the forest canopy and intermediate layers, the point density near the ground may be poor due to dense overstory conditions. The current study highlights a new method for detecting stems of single trees in 3D point clouds obtained from high density ALS with a density of 300 points/m2. Compared to standard ALS data, due to lower flight height (150-200 m) this elevated point density leads to more laser reflections from tree stems. In this work, we propose a three-tiered method which works on the point, segment and object levels. First, for each point we calculate the likelihood that it belongs to a tree stem, derived from the radiometric and geometric features of its neighboring points. In the next step, we construct short stem segments based on high-probability stem points, and classify the segments by considering the distribution of points around them as well as their spatial orientation, which encodes the prior knowledge that trees are mainly vertically aligned due to gravity. Finally, we apply hierarchical clustering on the positively classified segments to obtain point sets corresponding to single stems, and perform ℓ1-based orthogonal distance regression to robustly fit lines through each stem point set. The ℓ1-based method is less sensitive to outliers compared to the least square approaches. From the fitted lines, the planimetric tree positions can then be derived. Experiments were performed on two plots from the Hochficht forest in Oberösterreich region located in Austria.We marked a total of 196 reference stems in the point clouds of both plots by visual interpretation. The evaluation of the automatically detected stems showed a classification precision of 0.86 and 0.85, respectively for Plot 1 and 2, with recall values of 0.7 and 0.67.

  9. Multitype Events and the Analysis of Heart Failure Readmissions: Illustration of a New Modeling Approach and Comparison With Familiar Composite End Points.

    Science.gov (United States)

    Brown, Paul M; Ezekowitz, Justin A

    2017-06-01

    Heart failure-related hospital readmissions and mortality are often outcomes in clinical trials. Patients may experience multiple hospital readmissions over time with mortality acting as a dependent terminal event. Univariate composite end points are used for the analysis of readmissions. We may amend these approaches to include emergency department visits as a further outcome. An alternative multivariate modeling approach that categorizes hospital readmissions and emergency department visits as separate event types is proposed. We seek to compare the modeling approach which handles event types as separate, correlated end points against composites that amalgamate them to create a unified end point. Using a heart failure data set for illustration, a model with random effects for event types is estimated. The time-to-first event, unmatched win-ratio, and days-alive-and-out-of-hospital composites are derived for comparison. The model provides supplementary statistics such as the correlation among event types and yields considerably more power than the competing composite end points. The effect on individual outcomes is lost when they are intermingled to form a univariate composite. Simultaneously modeling different outcomes provides an alternative or supplementary analysis that may yield greater statistical power and additional insights. Improvements in software have made the multitype events model easier to implement and thus a useful, more efficient option when analyzing heart failure hospital readmissions and emergency department visits. © 2017 American Heart Association, Inc.

  10. A Single Case of Rosai-Dorfman Disease Marked by Pathologic Fractures, Kidney Failure, and Liver Cirrhosis Treated with Single-Agent Cladribine

    Directory of Open Access Journals (Sweden)

    Koji eSasaki

    2014-10-01

    Full Text Available Rosai-Dorfman disease (RDD is a proliferative histiocytic disorder of unknown etiology which is characterized by sinus histiocytosis with massive lymphadenopathy. In most cases, RDD has a benign course and treatment is not necessary. However, severe cases of RDD require treatment, and the treatment strategy is determined on the basis of the severity of the disease or the extranodal involvement of vital organs. We report a single case of RDD with atypical presentation of persistent constitutional symptoms, progressing pathologic fractures, and end-organ dysfunction, including acute kidney failure and liver cirrhosis with esophageal varices.

  11. A Direct Maximum Power Point Tracking Method for Single-Phase Grid Connected PV Inverters

    DEFF Research Database (Denmark)

    EL Aamri, Faicel; Maker, Hattab; Sera, Dezso

    2018-01-01

    in dynamic conditions, especially in low irradiance when the measurement of signals becomes more sensitive to noise. The proposed MPPT is designed for single-phase single-stage grid-connected PV inverters, and is based on estimating the instantaneous PV power and voltage ripples, using second...

  12. Single-Carrier Modulation for Neutral-Point-Clamped Inverters in Three-Phase Transformerless Photovoltaic Systems

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Cavalcanti, Marcelo C.; Farias, Alexandre M.

    2013-01-01

    Modulation strategy is one of the most important issues for three-level neutral-point-clamped inverters in three-phase transformerless photovoltaic systems. A challenge for modulation is how to keep the common-mode voltages constant to reduce the leakage currents. A single-carrier modulation...

  13. Electrically continuous graphene from single crystal copper verified by terahertz conductance spectroscopy and micro four-point probe

    DEFF Research Database (Denmark)

    Buron, Jonas Christian Due; Pizzocchero, Filippo; Jessen, Bjarke Sørensen

    2014-01-01

    . Micro four-point probe resistance values measured on graphene grown on single crystalline copper in two different voltage-current configurations show close agreement with the expected distributions for a continuous 2D conductor, in contrast with previous observations on graphene grown on commercial...... noninvasive conductance characterization methods: ultrabroadband terahertz time-domain spectroscopy and micro four-point probe, which probe the electrical properties of the graphene film on different length scales, 100 nm and 10 μm, respectively. Ultrabroadband terahertz time-domain spectroscopy allows...... copper foil. The terahertz and micro four-point probe conductance values of the graphene grown on single crystalline copper shows a close to unity correlation, in contrast with those of the graphene grown on commercial copper foil, which we explain by the absence of extended defects on the microscale...

  14. A Starting Point for Fluorescence-Based Single-Molecule Measurements in Biomolecular Research

    Directory of Open Access Journals (Sweden)

    Alexander Gust

    2014-09-01

    Full Text Available Single-molecule fluorescence techniques are ideally suited to provide information about the structure-function-dynamics relationship of a biomolecule as static and dynamic heterogeneity can be easily detected. However, what type of single-molecule fluorescence technique is suited for which kind of biological question and what are the obstacles on the way to a successful single-molecule microscopy experiment? In this review, we provide practical insights into fluorescence-based single-molecule experiments aiming for scientists who wish to take their experiments to the single-molecule level. We especially focus on fluorescence resonance energy transfer (FRET experiments as these are a widely employed tool for the investigation of biomolecular mechanisms. We will guide the reader through the most critical steps that determine the success and quality of diffusion-based confocal and immobilization-based total internal reflection fluorescence microscopy. We discuss the specific chemical and photophysical requirements that make fluorescent dyes suitable for single-molecule fluorescence experiments. Most importantly, we review recently emerged photoprotection systems as well as passivation and immobilization strategies that enable the observation of fluorescently labeled molecules under biocompatible conditions. Moreover, we discuss how the optical single-molecule toolkit has been extended in recent years to capture the physiological complexity of a cell making it even more relevant for biological research.

  15. Analysis of single point and continuous wave of condensation root filling techniques by micro-computed tomography

    Directory of Open Access Journals (Sweden)

    Daniele Angerame

    2012-01-01

    Full Text Available The aim of the present microtomographic study was to investigate the quality of root canal filling and the voids formation in canals of extracted teeth instrumented with a simultaneous technique and filled with two different methods. Twenty-four single-rooted teeth were assigned to two experimental groups (no. = 12; canals were shaped with NiTi rotary files, irrigated with NaOCl and filled either with the single point (group 1 or the continuous wave of condensation technique (group 2. Specimens underwent microtomographic scanning. Collected data were statistically analyzed by nonparametric methods. Void mean percentages were found to be limited and similar between the two groups; the single point technique led to greater sealer thickness in partially oval canals.

  16. How far can a rubber molecule stretch before breaking? Ab initio study of tensile elasticity and failure in single-molecule polyisoprene

    Energy Technology Data Exchange (ETDEWEB)

    Hanson, David E [Los Alamos National Laboratory

    2008-01-01

    We present ab initio calculations of the internal C-C bond dissociation curve for single molecules of (cis 1,4) polyisoprene, polybutadiene, and polyethylene, all of comparable length. We define 'bond rupture' as that point on the reaction coordinate where the unrestricted Kohn-Sham, or diradical, solution falls below the restricted, or closed-shell, solution. Using this well-defined though crude approximation, we find that rupture occurs at a tensile force of 6.8 nN for poly isoprene and 7.2 nN for polybutadiene. Their respective rupture strains are 45% and 42%. Our calculations show that the energy density vs. extension is not sensitive to the length of the molecule, i.e., it is essentially independent of the number of isoprene units contained. These relatively large rupture strains have important implications for understanding the failure mechanism in rubber, and imply that purely enthalpic chain stretching must commence well before tensile failure occurs.

  17. Etiologies, outcomes, and prognostic factors of pediatric acute liver failure: A single center's experience in Turkey.

    Science.gov (United States)

    Özçay, Figen; Karadağ Öncel, Eda; Barış, Zeren; Canan, Oğuz; Moray, Gökhan; Haberal, Mehmet

    2016-09-01

    Our aim was to determine the etiologies, outcomes, and prognostic indicators in children with acute liver failure. Ninety-one patients who were followed for pediatric acute liver failure (PALF) over a 15-year period were included. Patients who survived with supportive therapy were designated as Group 1, while those who died or underwent liver transplantation were designated as Group 2. There were 37 (40.6%) patients in Group 1 (spontaneous recovery) and 54 (59.4%) patients in Group 2. Thirty-two patients (35.2%) underwent liver transplantation. Infectious and indeterminate causes were the most common etiologies (33% each). Among the infectious causes, hepatitis A (76%) was the most frequent. Hepatic encephalopathy grade 3-4 on admission and during follow-up and high Pediatric Risk of Mortality (PRISM) and Pediatric End-Stage Liver Disease (PELD) scores within the first 24 h were related with a poor prognosis. Group 2 had a more prolonged prothrombin time, higher international normalized ratio, more prolonged activated partial thromboplastin time (aPTT), and higher levels of total and direct bilirubin, ammonia, and lactate (for all, pLiver transplantation was the only curative treatment for patients with poor prognoses and resulted in high survival rates (1-, 5-, and 10-year survival rates of 81.3%, 81.3%, and 75%, respectively) in our study.

  18. Single species biofilm-forming ability of root canal isolates on gutta-percha points.

    Science.gov (United States)

    Takemura, Naoki; Noiri, Yuichiro; Ehara, Atsushi; Kawahara, Takashi; Noguchi, Nobuo; Ebisu, Shigeyuki

    2004-12-01

    The participation of bacterial biofilms in the over-filled gutta-percha points associated with refractory periapical periodontitis has recently been reported. This study investigated the initial biofilm-forming ability of root canal isolates (Enterococcus faecalis, Streptococcus sanguis, Strep. intermedius, Strep. pyogenes, Staphylococcus aureus, Fusobacterium nucleatum, Propionibacterium acnes, Porphyromonas gingivalis and Prevotella intermedia) on gutta-percha points in vitro. Each bacterial strain was suspended in 100% cell culture medium or in culture medium containing 4.5, 45 or 90% (vol/vol) serum. The bacterial suspensions were then co-incubated anaerobically with gutta-percha points for 7 d. The gutta-percha points were processed for scanning electron microscopic observation and examined for biofilm presence and thickness. E. faecalis, Strep. sanguis, Strep. intermedius, Strep. pyogenes and Staph. aureus biofilms were generated on the surfaces of the specimens incubated in culture medium supplemented with 45 or 90% (vol/vol) serum. The E. faecalis and Strep. sanguis biofilms were significantly thicker than those of Strep. intermedius, Strep. pyogenes and Staph. aureus. No biofilms were detected on the specimens incubated with F. nucleatum, Prop. acnes, Porph. gingivalis and Prev. intermedia. These findings suggest that Gram-positive facultative anaerobes have the ability to colonize and form extracellular matrices on gutta-percha points, while serum plays a crucial role in biofilm formation. Copyright Eur J Oral Sci, 2004.

  19. A Single-Center, Adult Chronic Intestinal Failure Cohort Analyzed According to the ESPEN-Endorsed Recommendations, Definitions, and Classifications

    DEFF Research Database (Denmark)

    Brandt, Christopher Filtenborg; Tribler, Siri; Hvistendahl, Mark

    2017-01-01

    BACKGROUND/AIMS: The objective of this study was to describe a clinically well-defined, single-center, intestinal failure (IF) cohort based on a template of definitions and classifications endorsed by the European Society for Clinical Nutrition and Metabolism (ESPEN). METHODS: A cross-sectional, ......BACKGROUND/AIMS: The objective of this study was to describe a clinically well-defined, single-center, intestinal failure (IF) cohort based on a template of definitions and classifications endorsed by the European Society for Clinical Nutrition and Metabolism (ESPEN). METHODS: A cross...... fluids and electrolytes, while 97% required parenteral energy (17 ± 12 kcal/kg/d). Although 92% of the cohort had undergone intestinal resection, only 53% were classified as patients with short bowel syndrome (SBS) according to the pathophysiological classification. In the remaining cohort, patients were...... = 82), group 2 (jejuno-colonic-anastomosis, n = 16), and group 3 (jejuno-ileo-colonic-anastomosis, n = 2). When evaluating the cohort requirements for PS using the ESPEN chronic IF classification based on the need for fluid volume and energy, 53% of the patients with IF were distributed in the maximum...

  20. Analytical and semi-analytical inverse kinematics of SSRMS-type manipulators with single joint locked failure

    Science.gov (United States)

    Xu, Wenfu; She, Yu; Xu, Yangsheng

    2014-12-01

    Redundant space manipulators, including Space Station Remote Manipulator System (SSRMS), Special Purpose Dexterous Manipulator (SPDM) and European Robotic Arm (ERA), have been playing important roles in the construction and maintenance of International Space Station (ISS). They all have 7 revolute joints arranged in similar configurations, and are referred to as SSRMS-type manipulators. When a joint is locked in an arbitrary position due to some failures, a 7R manipulator degrades to a 6R manipulator. Without a spherical wrist or three consecutive parallel joints, the inverse kinematics of the 6R manipulator is very complex. In this paper, we propose effective methods to resolve the inverse kinematics for different cases of any joint locked in an arbitrary position. Firstly, configuration characteristics of the SSRMS-type redundant manipulators are analyzed. Then, an existing of closed-form inverse kinematics is discussed for locking different joints. Secondly, D-H frames and corresponding D-H parameters of the new 6-DOF manipulator formed by locking a joint in an arbitrary position are re-constructed. A unified table is then created to describe the kinematics for all possible cases of single joint locking failure. Thirdly, completely analytical and semi-analytical methods are presented to solve the inverse kinematics equations, and the former is used for locking joint 1, 2, 6 or 7 while the latter for locking joint 3, 4 or 5. Finally, typical cases for single joint locking are studied. The results verify the proposed methods.

  1. X-Ray Radiography of Three-Point Bending of Single Human Trabecula

    Czech Academy of Sciences Publication Activity Database

    Jiroušek, Ondřej; Doktor, Tomáš; Kytýř, Daniel; Zlámal, Petr

    2012-01-01

    Roč. 45, S1 (2012), s. 261-261 ISSN 0021-9290 R&D Projects: GA ČR(CZ) GAP105/10/2305 Institutional support: RVO:68378297 Keywords : microspheres * strain measurement * three-point bending * trabecular bone * X-ray radiography Subject RIV: FI - Traumatology, Orthopedics Impact factor: 2.716, year: 2012

  2. Shape measurement system for single point incremental forming (SPIF) manufacts by using trinocular vision and random pattern

    International Nuclear Information System (INIS)

    Setti, Francesco; Bini, Ruggero; Lunardelli, Massimo; Bosetti, Paolo; Bruschi, Stefania; De Cecco, Mariolino

    2012-01-01

    Many contemporary works show the interest of the scientific community in measuring the shape of artefacts made by single point incremental forming. In this paper, we will present an algorithm able to detect feature points with a random pattern, check the compatibility of associations exploiting multi-stereo constraints and reject outliers and perform a 3D reconstruction by dense random patterns. The algorithm is suitable for a real-time application, in fact it needs just three images and a synchronous relatively fast processing. The proposed method has been tested on a simple geometry and results have been compared with a coordinate measurement machine acquisition. (paper)

  3. A High-Power-Density Single-Phase Rectifier Based on Three-Level Neutral-Point Clamped Circuits

    Directory of Open Access Journals (Sweden)

    Tao Zhou

    2017-05-01

    Full Text Available A single-phase three-level converter is suitable for medium-power applications, with an interface voltage that is higher than that of a traditional two-level configuration. The three-level neutral-point clamped converter is adopted using four switches in each bridge arm, which, compared to a two-level rectifier, leads to less voltage stress, a lower switching frequency, and switching loss on switches. The transient current control strategy is designed to control the active power. The single-phase space vector pulse width modulation (SVPWM with a voltage balance strategy is designed to solve the neutral point voltage fluctuation problem and keep the dc-link voltage stable. A 1.3 kW high-power-density prototype based on SiC MOSFET was built and tested. The experimental results verified the high performance of steady-state and dynamic responses.

  4. Highly macroscopically degenerated single-point ground states as source of specific heat capacity anomalies in magnetic frustrated systems

    Science.gov (United States)

    Jurčišinová, E.; Jurčišin, M.

    2018-04-01

    Anomalies of the specific heat capacity are investigated in the framework of the exactly solvable antiferromagnetic spin- 1 / 2 Ising model in the external magnetic field on the geometrically frustrated tetrahedron recursive lattice. It is shown that the Schottky-type anomaly in the behavior of the specific heat capacity is related to the existence of unique highly macroscopically degenerated single-point ground states which are formed on the borders between neighboring plateau-like ground states. It is also shown that the very existence of these single-point ground states with large residual entropies predicts the appearance of another anomaly in the behavior of the specific heat capacity for low temperatures, namely, the field-induced double-peak structure, which exists, and should be observed experimentally, along with the Schottky-type anomaly in various frustrated magnetic system.

  5. Characteristics of X-point lobe structures in single-null discharges on MAST

    Czech Academy of Sciences Publication Activity Database

    Harrison, J.R.; Kirk, A.; Chapman, I.T.; Cahyna, Pavel; Liu, Y.; Nardon, E.; Thornton, A.J.

    2014-01-01

    Roč. 54, č. 6 (2014), 064015-064015 ISSN 0029-5515 R&D Projects: GA ČR GAP205/11/2341 Institutional support: RVO:61389021 Keywords : tokamak * MAST * X-point * resonant magnetic perturbation Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 3.062, year: 2014 http://iopscience.iop.org/0029-5515/54/6/064015/pdf/0029-5515_54_6_064015.pdf

  6. Characterization of Point Defects in Lithium Aluminate (LiAlO2) Single Crystals

    Science.gov (United States)

    2015-09-17

    insulating wide-band gap material currently under development for tritium breeding and radiation detection and dosimetry appli- cations. Point defects...110 xi List of Tables Table Page 1.1. Anion - Cation Bond Lengths...the valence band from the bottom of the conduction band is known as the band gap energy, and is normally represented by Eg. If a photon with an energy

  7. A QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices.

    Science.gov (United States)

    Chen, Chieh-Li; Chuang, Chun-Te

    2017-08-26

    In the new-generation wearable Electrocardiogram (ECG) system, signal processing with low power consumption is required to transmit data when detecting dangerous rhythms and to record signals when detecting abnormal rhythms. The QRS complex is a combination of three of the graphic deflection seen on a typical ECG. This study proposes a real-time QRS detection and R point recognition method with low computational complexity while maintaining a high accuracy. The enhancement of QRS segments and restraining of P and T waves are carried out by the proposed ECG signal transformation, which also leads to the elimination of baseline wandering. In this study, the QRS fiducial point is determined based on the detected crests and troughs of the transformed signal. Subsequently, the R point can be recognized based on four QRS waveform templates and preliminary heart rhythm classification can be also achieved at the same time. The performance of the proposed approach is demonstrated using the benchmark of the MIT-BIH Arrhythmia Database, where the QRS detected sensitivity (Se) and positive prediction (+P) are 99.82% and 99.81%, respectively. The result reveals the approach's advantage of low computational complexity, as well as the feasibility of the real-time application on a mobile phone and an embedded system.

  8. Optimal fits of diffusion constants from single-time data points of Brownian trajectories.

    Science.gov (United States)

    Boyer, Denis; Dean, David S; Mejía-Monasterio, Carlos; Oshanin, Gleb

    2012-12-01

    Experimental methods based on single particle tracking (SPT) are being increasingly employed in the physical and biological sciences, where nanoscale objects are visualized with high temporal and spatial resolution. SPT can probe interactions between a particle and its environment but the price to be paid is the absence of ensemble averaging and a consequent lack of statistics. Here we address the benchmark question of how to accurately extract the diffusion constant of one single Brownian trajectory. We analyze a class of estimators based on weighted functionals of the square displacement. For a certain choice of the weight function these functionals provide the true ensemble averaged diffusion coefficient, with a precision that increases with the trajectory resolution.

  9. Point defects and electric compensation in gallium arsenide single crystals; Punktdefekte und elektrische Kompensation in Galliumarsenid-Einkristallen

    Energy Technology Data Exchange (ETDEWEB)

    Kretzer, Ulrich

    2007-12-10

    In the present thesis the point-defect budget of gallium arsenide single crystals with different dopings is studied. It is shown, in which way the concentration of the single point defects depende on the concentration of the dopants, the stoichiometry deviation, and the position of the Fermi level. For this serve the results of the measurement-technical characterization of a large number of samples, in the fabrication of which these parameters were directedly varied. The main topic of this thesis lies in the development of models, which allow a quantitative description of the experimentally studied electrical and optical properties of gallium arsenide single crystals starting from the point-defect concentrations. Because from point defects charge carriers can be set free, their concentration determines essentially the charge-carrier concentration in the bands. In the ionized state point defects act as scattering centers for free charge carriers and influence by this the drift mobility of the charge carriers. A thermodynamic modeling of the point-defect formation yields statements on the equilibrium concentrations of the point defects in dependence on dopant concentration and stoichiometry deviation. It is show that the electrical properties of the crystals observed at room temperature result from the kinetic suppression of processes, via which the adjustment of a thermodynamic equilibrium between the point defects is mediated. [German] In der vorliegenden Arbeit wird der Punktdefekthaushalt von Galliumarsenid-Einkristallen mit unterschiedlichen Dotierungen untersucht. Es wird gezeigt, in welcher Weise die Konzentration der einzelnen Punktdefekte von der Konzentration der Dotierstoffe, der Stoechiometrieabweichung und der Lage des Ferminiveaus abhaengen. Dazu dienen die Ergebnisse der messtechnischen Charakterisierung einer grossen Anzahl von Proben, bei deren Herstellung diese Parameter gezielt variiert wurden. Der Schwerpunkt der Arbeit liegt in der Entwicklung

  10. Single-point reactive power control method on voltage rise mitigation in residential networks with high PV penetration

    DEFF Research Database (Denmark)

    Hasheminamin, Maryam; Agelidis, Vassilios; Ahmadi, Abdollah

    2018-01-01

    Voltage rise (VR) due to reverse power flow is an important obstacle for high integration of Photovoltaic (PV) into residential networks. This paper introduces and elaborates a novel methodology of an index-based single-point-reactive power-control (SPRPC) methodology to mitigate voltage rise by ...... system with high r/x ratio. Efficacy, effectiveness and cost study of SPRPC is compared to droop control to evaluate its advantages....... by absorbing adequate reactive power from one selected point. The proposed index utilizes short circuit analysis to select the best point to apply this Volt/Var control method. SPRPC is supported technically and financially by distribution network operator that makes it cost effective, simple and efficient...

  11. Examples of deletion of single component failure mode on fuelling machine hoist system

    International Nuclear Information System (INIS)

    Arthurs, D.L.

    1986-01-01

    Strachan and Henshaw AGR Fuelling Machine designs have previously used two completely independent hoist chains for reactor component handling. For Heysham II/Torness the concept has been extended to include the headshaft which carries the chain sprockets. The design described in the paper now includes a duplicate load path through all components from the chain/grab attachment through to the emergency headshaft brakes. The machine grab comprises a single main forged body with a very high load factor of safety. Studies are being undertaken to provide a second load path through the grab. (author)

  12. New, multi-dimensional reconstructions for the 12-detector, scanned focal point, single-photon tomograph

    International Nuclear Information System (INIS)

    Stoddart, H.A.; Stoddart, H.F.

    1990-01-01

    The heuristic reconstruction process used for the highly-focused, scanned focal-point tomograph described by us in 1979 has remained unchanged until recently. This paper describes an entirely new and completely rigorous reconstruction for this unique geometry which produces dramatically improved images that are least square estimates of the objects. The handling of attenuation, scattering, and object power spectra are discussed. Reconstructions are described for 2D, 3D from three slices, time varying 3D from three slices, and 3D from a large set of slices. Reconstructions for simulated and actual clinical data are shown and the accuracy for quantitation is estimated

  13. Prediction of effects of punch shapes on tableting failure by using a multi-functional single-punch tablet press

    Directory of Open Access Journals (Sweden)

    Takashi Osamura

    2017-09-01

    Full Text Available We previously determined “Tableting properties” by using a multi-functional single-punch tablet press (GTP-1. We proposed plotting “Compactability” on the x-axis against “Manufacturability” on the y-axis to allow visual evaluation of “Tableting properties”. Various types of tableting failure occur in commercial drug production and are influenced by the amount of lubricant used and the shape of the punch. We used the GTP-1 to measure “Tableting properties” with different amounts of lubricant and compared the results with those of tableting on a commercial rotary tableting machine. Tablets compressed with a small amount of lubricant showed bad “Manufacturability”, leading to sticking of powder on punches. We also tested various punch shapes. The GTP-1 correctly predicted the actual tableting results for all punch shapes. With punches that were more likely to cause tableting failure, our system predicted the effects of lubricant quantity in the tablet formulation and the occurrence of sticking in the rotary tableting machine.

  14. Ultrasonically Assisted Single Point Diamond Turning of Optical Mold of Tungsten Carbide

    Directory of Open Access Journals (Sweden)

    Zhanjie Li

    2018-02-01

    Full Text Available To realize high efficiency, low/no damage and high precision machining of tungsten carbide used for lens mold, a high frequency ultrasonic vibration cutting system was developed at first. Then, tungsten carbide was precisely machined with a polycrystalline diamond (PCD tool assisted by the self-developed high frequency ultrasonic vibration cutting system. Tool wear mechanism was investigated in ductile regime machining of tungsten carbide. The cutter back-off phenomenon in the process was analyzed. The subsequent experimental results of ultra-precision machining with a single crystal diamond tool showed that: under the condition of high frequency ultrasonic vibration cutting, nano-scale surface roughness can be obtained by the diamond tool with smaller tip radius and no defects like those of ground surface were found on the machined surface. Tool wear mechanisms of the single crystal diamond tool are mainly abrasive wear and micro-chipping. To solve the problem, a method of inclined ultrasonic vibration cutting with negative rake angle was put forward according to force analysis, which can further reduce tool wear and roughness of the machined surface. The investigation was important to high efficiency and quality ultra-precision machining of tungsten carbide.

  15. Failure of single electron descriptions of molecular orbital collision processes. [Electron promotion mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Elston, S.B.

    1978-01-01

    Inner-shell excitation occurring in low and moderate (keV range) energy collisions between light atomic and ionic systems is frequently describable in terms of molecular promotion mechanisms, which were extensively explored both theoretically and experimentally. The bulk of such studies have concentrated on processes understandable through the use of single- and independent-electron models. Nonetheless, it is possible to find cases of inner-shell excitation in relatively simple collision systems which involve nearly simultaneous multiple-electron transitions and transitions induced by inherently two-electron interactions. Evidence for these many- and nonindependent-electron phenomena in inner-shell excitation processes and the importance of considering such effects in the interpretation of collisionally induced excitation spectra is discussed. 13 references.

  16. Epidemiology of chronic renal failure in Iran: A four year single center experience

    International Nuclear Information System (INIS)

    Afshar, R.; Sanavi, S.; Salimi, J.

    2007-01-01

    Chronic renal failure (CRF) is a major public health problem. Early diagnosis and proper management have important roles in prevention of CRF progression to end-stage renal disease (ESRD). For this purpose, determining the etiology of CRF may be helpful. This study was conducted in the nephrology department at the Mostafa Khomeini Hospital in Tehran, Iran from March 2001 to March 2005, to determine the etiology of CRF in adult Iranian patients. A total of 1200 patients with a diagnosis of CRF were involved in the study. Relevant data were collected using a reliable questionnaire. All data analyses were carried out using SPSS and the x2 test. Of the 1200 patients, 61% were males and 39% females. The most frequent age group was 61-75 years (38.3%) and the mean age of study patients was 51.6 +- 17 years. The etiology of CRF in our series included diabetes mellitus in 26.8%, hypertension in 13.5%, obstructive uropathy in 12%, cystic and congenital disorders in 10.3%, glomerulonephritis in 6.5%, urinary tract infections in 4%, vasculitis in 2%, tubulo-interstitial nephritis and pregnancy related in 0.8% each and unknown causes in 29.5% of the patients. Laboratory and ultrasonographic assessment at initiation of the study revealed blood urea nitrogen >100 mg/dl in 57.8% of the patients, serum creatinine >10mg/dl in 40.3%, glomerular filtration rate (GFR) < 10ml/min in 61.3%, hemoglobin < 10 g/dl in 65.8% and kidney size lesser than 8 cm in 46% of the cases. There was a significant statistical relationship between kidney size and duration of hypertension greater than five years (P=0.017). The high frequency of CRF of unknown etiology in this study may be attributed to diagnostic limitations prevailing in our country. A GFR of < 10 ml/min in 61.3% of these cases at presentation suggests late diagnosis/ and/or referral. Aggressive screening and treatment strategies to prevent ESRD are recommended. (author)

  17. Hepatitis G virus infection in Egyptian children with chronic renal failure (single centre study

    Directory of Open Access Journals (Sweden)

    Zaghloul Mohammad

    2009-12-01

    Full Text Available Abstract Background Hepatitis G virus (HGV is an RNA virus. It is mainly transmitted through exposure to contaminated blood although other routes may also exist. Patients with chronic renal failure (CRF are at high risk of acquiring HGV because they require frequent blood transfusions. Ongoing HGV infection can be only diagnosed by demonstrating viremia in patient sample by reverse transcriptase (RT PCR. Antibodies to the envelop protein E2 (anti E2 of HGV is an indicator of virus clearance and testify past HGV contact. This cross sectional study was done to assess the frequency of HGV exposure (ongoing and past infection in Egyptian children with CRF and to study the possible risk factors of infection. Methods This study included 100 children with CRF [34 on regular haemodialysis (HD and 66 before the start of dialysis (predialysis]. All patients sera were tested for HGV RNA by RT-PCR, anti E2, hepatitis C virus (HCV antibody, hepatitis B surface antigen (HBsAg, and hepatitis B core antibody (HBcAB. Twenty five healthy children of matched age & sex were used as controls. Results HGV RNA was positive in 9 (26.5% of HD and 9 (13.6% of predialysis children. Anti E2 was positive in 14 (41.2% of HD and 19 (28.8% of predialysis children. In comparison to controls; CRF (n = 100; HD and predialysis children had significantly higher prevalence of anti E2 [4% VS 33% for all CRF cases; (p = 0.002& 41.2% (p = 0.002 and 28.8% (p = 0.01; for HD and predialysis groups; respectively]. HGV RNA was significantly more prevalent only in HD children in comparison to controls (p = 0.03. HD and predialysis children did not have significant difference in the prevalence of HGV RNA (p = 0.16 or anti E2 (p = 0.26. HGV exposure was not correlated with positivity of anti HCV (p = 0.32, HCV RNA (0.09, HBsAg/HBcAB (p = 1, age (p = 0.06, or gender (p = 0.83. It was significantly correlated with duration of the disease (p Conclusions The frequency of HGV exposure in Egyptian

  18. CScape: a tool for predicting oncogenic single-point mutations in the cancer genome.

    Science.gov (United States)

    Rogers, Mark F; Shihab, Hashem A; Gaunt, Tom R; Campbell, Colin

    2017-09-14

    For somatic point mutations in coding and non-coding regions of the genome, we propose CScape, an integrative classifier for predicting the likelihood that mutations are cancer drivers. Tested on somatic mutations, CScape tends to outperform alternative methods, reaching 91% balanced accuracy in coding regions and 70% in non-coding regions, while even higher accuracy may be achieved using thresholds to isolate high-confidence predictions. Positive predictions tend to cluster in genomic regions, so we apply a statistical approach to isolate coding and non-coding regions of the cancer genome that appear enriched for high-confidence predicted disease-drivers. Predictions and software are available at http://CScape.biocompute.org.uk/ .

  19. Potential use of point shear wave elastography for the pancreas: A single center prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Kawada, Natsuko, E-mail: kawada-na@mc.pref.osaka.jp [Department of Pathology, Osaka Medical Center for Cancer and Cardiovascular Diseases, 1-3-3 Nakamichi, Higashinari, Osaka 537-8511 (Japan); Department of Gastroenterology, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Ishikawa 920-0293 (Japan); Tanaka, Sachiko, E-mail: sachi686@cocoa.plala.or.jp [Osaka Center for Cancer and Cardiovascular Disease Prevention, 1-6-107, Morinomiya, Johtoh, Osaka 536-8588 (Japan); Uehara, Hiroyuki, E-mail: uehara-hi@mc.pref.osaka.jp [Department of Gastroenterology, Osaka Medical Center for Cancer and Cardiovascular Diseases, 1-3-3 Nakamichi, Higashinari, Osaka 537-8511 (Japan); Ohkawa, Kazuyoshi, E-mail: okawa-ka@mc.pref.osaka.jp [Department of Gastroenterology, Osaka Medical Center for Cancer and Cardiovascular Diseases, 1-3-3 Nakamichi, Higashinari, Osaka 537-8511 (Japan); Yamai, Takuo, E-mail: yamai-ta@mc.pref.osaka.jp [Department of Gastroenterology, Osaka Medical Center for Cancer and Cardiovascular Diseases, 1-3-3 Nakamichi, Higashinari, Osaka 537-8511 (Japan); Takada, Ryoji, E-mail: takada-ry@mc.pref.osaka.jp [Department of Gastroenterology, Osaka Medical Center for Cancer and Cardiovascular Diseases, 1-3-3 Nakamichi, Higashinari, Osaka 537-8511 (Japan); Shiroeda, Hisakazu, E-mail: shiroeda@kanazawa-med.ac.jp [Department of Gastroenterology, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Ishikawa 920-0293 (Japan); Arisawa, Tomiyasu, E-mail: tarisawa@kanazawa-med.ac.jp [Department of Gastroenterology, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Ishikawa 920-0293 (Japan); Tomita, Yasuhiko, E-mail: tomota-ya@mc.pref.osaka.jp [Department of Pathology, Osaka Medical Center for Cancer and Cardiovascular Diseases, 1-3-3 Nakamichi, Higashinari, Osaka 537-8511 (Japan)

    2014-04-15

    Aim: Clinical use of point shear wave elastography for the liver has been established, however, few studies demonstrated its usefulness for the pancreas. A prospective study was conducted to clarify its feasibility for the pancreas and its usefulness for the identification of high risk group for pancreatic cancer. Patients and methods: Consecutive eighty-five patients underwent point shear wave elastography for the pancreas. The success rate of shear wave velocity (SWV) measurement, that is the number of successful measurements over total 10 measurements, was recorded. The SWV of the pancreas measured at non-tumorous area was compared between patients with and without pancreatic cancer. Factors associated with high SWV were determined by logistic regression model. Results: Sixty patients were included, of these 18 had pancreatic cancer. The success rate of 100% was achieved at the head, the body and the tail of the pancreas in 80%, 83%, and 68% of the patients, respectively. The success rate of ≥80% was achieved in 100%, 100%, and 96% of the patients, respectively. Although mean SWV of the pancreas harboring pancreatic cancer tended to be higher compared with that of the pancreas without cancer (1.51 ± 0.45 m/s vs 1.43 ± 0.28 m/s), they did not reach statistical significance. Multivariate analysis showed that increased amount of alcohol intake was associated with high SWV. Conclusion: The SWV of the pancreas was measured with excellent success rate. However, tendency of higher SWV obtained from the pancreas harboring pancreatic cancer needed to be further investigated.

  20. Self-ordered pointing in children with autism: failure to use verbal mediation in the service of working memory?

    Science.gov (United States)

    Joseph, Robert M; Steele, Shelley D; Meyer, Echo; Tager-Flusberg, Helen

    2005-01-01

    This study tested the hypothesis that children with autism are impaired in using verbal encoding and rehearsal strategies in the service of working memory. Participants were 24 high-ability, school-age children with autism and a comparison group matched on verbal and non-verbal IQ, receptive and expressive vocabulary, and visual memory. Working memory was assessed using verbal and non-verbal variants of a non-spatial, self-ordered pointing test [Petrides, M., & Milner, B. (1982). Deficits on subject-ordered tasks after frontal- and temporal-lobe lesions in man. Neuropsychologia, 20, 249-262] in which children had to point to a new stimulus in a set upon each presentation without repeating a previous choice. In the verbal condition, the stimuli were pictures of concrete, nameable objects, whereas in the non-verbal condition, the stimuli were not easily named or verbally encoded. Participants were also administered a verbal span task to assess non-executive verbal rehearsal skills. Although the two groups were equivalent in verbal rehearsal skills, the autism group performed significantly less well in the verbal, but not the non-verbal, self-ordered pointing test. These findings suggested that children with autism are deficient in the use of verbal mediation strategies to maintain and monitor goal-related information in working memory. The findings are discussed in terms of possible autistic impairments in episodic memory as well as working memory.

  1. Design of thermostable rhamnogalacturonan lyase mutants from Bacillus licheniformis by combination of targeted single point mutations

    DEFF Research Database (Denmark)

    da Silva, Ines Isabel Cardoso Rodrigues; Jers, Carsten; Otten, Harm

    2014-01-01

    Rhamnogalacturonan I lyases (RGI lyases) (EC 4.2.2.-) catalyze cleavage of α-1,4 bonds between rhamnose and galacturonic acid in the backbone of pectins by β-elimination. In the present study, targeted improvement of the thermostability of a PL family 11 RGI lyase from Bacillus licheniformis (DSM...... the wild-type RGI lyase in Bacillus subtilis as opposed to in Pichia pastoris; this effect is suggested to be a negative result of glycosylation of the P. pastoris expressed enzyme. A ~ twofold improvement in thermal stability at 60 °C, accompanied by less significant increases in Tm of the enzyme mutants......, were obtained due to additive stabilizing effects of single amino acid mutations (E434L, G55V, and G326E) compared to the wild type. The crystal structure of the B. licheniformis wild-type RGI lyase was also determined; the structural analysis corroborated that especially mutation of charged amino...

  2. A study of point defect aggregates in #betta#-irradiated LiF single crystals

    International Nuclear Information System (INIS)

    Frugoli, P.A.; Pimentel, C.A.F.

    1982-11-01

    Diffuse X-ray scattering near the Bragg Reflection and Bragg profile analaysis have been made in #betta#-irradiated LiF single crystal X-ray diffractometer. An estimate of the half-width of the diffraction patterns was done and preferential alteration in the profile parameters was observed. Clusters with mean parameter sizes from hundreds to thousands of angstroms were observed but each sample has presented a set of average size values. The nature of clusters was found to be dependent on the #betta#-dose: vacancy at low dose (approximately 10 MRad) and interstitial at high dose (approximately 50 MRad). Some process of coalescence at 50 MRad seems to occur. (Author) [pt

  3. ACUTE RENAL FAILURE WITH NORMAL PLASMA UREA LEVEL SECONDARY TO ACUTE PYELONEPHITIS IN A SINGLE KIDNEY PATIENT

    Directory of Open Access Journals (Sweden)

    Algranati L

    2007-04-01

    Full Text Available SUMMARY: Acute renal failure is a syndrome that usually runs with an increase in creatinine and urea plasma levels. However, there are clinical situations in which this syndrome may run with an increase in plasma creatinine keeping normal the urea one. In this report we present a case of acute renal failure with normal plasma urea level secondary to an acute pyelonephritis in a single kidney patient. The patient had an increased fractional excretion of urea which could explain the normal plasma urea levels found despite of his reduced glomerular filtration. This increased urea excretion state was interpreted as a consequence of the nephrogenic diabetes insipidus and alteration of the intra-renal urea reciclying process that the acute pyelonephritis induced. In conclusion: Acute pyelonephritis in a single kidney patient can appear as a pattern of acute renal failure with normal plasma urea levels.RESUMEN: La insuficiencia renal aguda es un sindrome que característicamente cursa con niveles plasmáticos elevados de urea y creatinina. Sin embargo, hay situaciones clínicas en las cuales este sindrome puede cursar con un incremento de la creatininemia sin presentar elevación de la uremia. En este reporte presentamos un caso clínico de una insuficiencia renal aguda con uremia normal secundaria a una pielonefritis aguda en un paciente con riñón único. El paciente presentaba una elevada excreción fraccional de urea lo cual podía explicar su uremia normal pese a estar cursando una caída del filtrado gomerular. Dicha excreción de urea elevada fue interpretada como secundaria a una diabetes insipida nefrogénica y una alteración en el recirculado intra-renal de la urea ambos producto de la pielonefritis aguda. Concluimos que la pielonefritis aguda en un paciente mono-reno puede presentarse con un patrón de insuficiencia renal aguda con uremia normal.

  4. ACUTE RENAL FAILURE WITH NORMAL PLASMA UREA LEVEL SECONDARY TO ACUTE PYELONEPHITIS IN A SINGLE KIDNEY PATIENT

    Directory of Open Access Journals (Sweden)

    Imperiali N

    2006-03-01

    Full Text Available SUMMARYAcute renal failure is a syndrome that usually runs with an increase in creatinine and urea plasma levels. However, there are clinical situations in which this syndrome may run with an increase in plasma creatinine keeping normal the urea one.In this report we present a case of acute renal failure with normal plasma urea level secondary to an acute pyelonephritis in a single kidney patient. The patient had an increased fractional excretion of urea which could explain the normal plasma urea levels found despite of his reduced glomerular filtration. This increased urea excretion state was interpreted as a consequence of the nephrogenic diabetes insipidus and alteration of the intra-renal urea reciclying process that the acute pyelonephritis induced. In conclusion: Acute pyelonephritis in a single kidney patient can appear as a pattern of acute renal failure with normal plasma urea levels. RESUMEN:La insuficiencia renal aguda es un sindrome que característicamente cursa con niveles plasmáticos elevados de urea y creatinina. Sin embargo, hay situaciones clínicas en las cuales este sindrome puede cursar con un incremento de la creatininemia sin presentar elevación de la uremia.En este reporte presentamos un caso clínico de una insuficiencia renal aguda con uremia normal secundaria a una pielonefritis aguda en un paciente con riñón único. El paciente presentaba una elevada excreción fraccional de urea lo cual podía explicar su uremia normal pese a estar cursando una caída del filtrado gomerular. Dicha excreción de urea elevada fue interpretada como secundaria a una diabetes insipida nefrogénica y una alteración en el recirculado intra-renal de la urea ambos producto de la pielonefritis aguda. Concluimos que la pielonefritis aguda en un paciente mono-reno puede presentarse con un patrón de insuficiencia renal aguda con uremia normal.

  5. Action potential-evoked calcium release is impaired in single skeletal muscle fibers from heart failure patients.

    Directory of Open Access Journals (Sweden)

    Marino DiFranco

    Full Text Available Exercise intolerance in chronic heart failure (HF has been attributed to abnormalities of the skeletal muscles. Muscle function depends on intact excitation-contraction coupling (ECC, but ECC studies in HF models have been inconclusive, due to deficiencies in the animal models and tools used to measure calcium (Ca2+ release, mandating investigations in skeletal muscle from HF patients. The purpose of this study was to test the hypothesis that Ca2+ release is significantly impaired in the skeletal muscle of HF patients in whom exercise capacity is severely diminished compared to age-matched healthy volunteers.Using state-of-the-art electrophysiological and optical techniques in single muscle fibers from biopsies of the locomotive vastus lateralis muscle, we measured the action potential (AP-evoked Ca2+ release in 4 HF patients and 4 age-matched healthy controls. The mean peak Ca2+ release flux in fibers obtained from HF patients (10±1.2 µM/ms was markedly (2.6-fold and significantly (p<0.05 smaller than in fibers from healthy volunteers (28±3.3 µM/ms. This impairment in AP-evoked Ca2+ release was ubiquitous and was not explained by differences in the excitability mechanisms since single APs were indistinguishable between HF patients and healthy volunteers.These findings prove the feasibility of performing electrophysiological experiments in single fibers from human skeletal muscle, and offer a new approach for investigations of myopathies due to HF and other diseases. Importantly, we have demonstrated that one step in the ECC process, AP-evoked Ca2+ release, is impaired in single muscle fibers in HF patients.

  6. Hepatitis G virus infection in Egyptian children with chronic renal failure (single centre study)

    Science.gov (United States)

    2009-01-01

    Background Hepatitis G virus (HGV) is an RNA virus. It is mainly transmitted through exposure to contaminated blood although other routes may also exist. Patients with chronic renal failure (CRF) are at high risk of acquiring HGV because they require frequent blood transfusions. Ongoing HGV infection can be only diagnosed by demonstrating viremia in patient sample by reverse transcriptase (RT) PCR. Antibodies to the envelop protein E2 (anti E2) of HGV is an indicator of virus clearance and testify past HGV contact. This cross sectional study was done to assess the frequency of HGV exposure (ongoing and past infection) in Egyptian children with CRF and to study the possible risk factors of infection. Methods This study included 100 children with CRF [34 on regular haemodialysis (HD) and 66 before the start of dialysis (predialysis)]. All patients sera were tested for HGV RNA by RT-PCR, anti E2, hepatitis C virus (HCV) antibody, hepatitis B surface antigen (HBsAg), and hepatitis B core antibody (HBcAB). Twenty five healthy children of matched age & sex were used as controls. Results HGV RNA was positive in 9 (26.5%) of HD and 9 (13.6%) of predialysis children. Anti E2 was positive in 14 (41.2%) of HD and 19 (28.8%) of predialysis children. In comparison to controls; CRF (n = 100); HD and predialysis children had significantly higher prevalence of anti E2 [4% VS 33% for all CRF cases; (p = 0.002)& 41.2% (p = 0.002) and 28.8% (p = 0.01); for HD and predialysis groups; respectively]. HGV RNA was significantly more prevalent only in HD children in comparison to controls (p = 0.03). HD and predialysis children did not have significant difference in the prevalence of HGV RNA (p = 0.16) or anti E2 (p = 0.26). HGV exposure was not correlated with positivity of anti HCV (p = 0.32), HCV RNA (0.09), HBsAg/HBcAB (p = 1), age (p = 0.06), or gender (p = 0.83). It was significantly correlated with duration of the disease (p < 0.001). Ongoing HGV infection was significantly more

  7. High-performance analysis of single interphase cells with custom DNA probes spanning translocation break points

    Science.gov (United States)

    Weier, Heinz-Ulli G.; Munne, S.; Lersch, Robert A.; Marquez, C.; Wu, J.; Pedersen, Roger A.; Fung, Jingly

    1999-06-01

    The chromatin organization of interphase cell nuclei, albeit an object of intense investigation, is only poorly understood. In the past, this has hampered the cytogenetic analysis of tissues derived from specimens where only few cells were actively proliferating or a significant number of metaphase cells could be obtained by induction of growth. Typical examples of such hard to analyze cell systems are solid tumors, germ cells and, to a certain extent, fetal cells such as amniocytes, blastomeres or cytotrophoblasts. Balanced reciprocal translocations that do not disrupt essential genes and thus do not led to disease symptoms exit in less than one percent of the general population. Since the presence of translocations interferes with homologue pairing in meiosis, many of these individuals experience problems in their reproduction, such as reduced fertility, infertility or a history of spontaneous abortions. The majority of translocation carriers enrolled in our in vitro fertilization (IVF) programs carry simple translocations involving only two autosomes. While most translocations are relatively easy to spot in metaphase cells, the majority of cells biopsied from embryos produced by IVF are in interphase and thus unsuitable for analysis by chromosome banding or FISH-painting. We therefore set out to analyze single interphase cells for presence or absence of specific translocations. Our assay, based on fluorescence in situ hybridization (FISH) of breakpoint-spanning DNA probes, detects translocations in interphase by visual microscopic inspection of hybridization domains. Probes are prepared so that they span a breakpoint and cover several hundred kb of DNA adjacent to the breakpoint. On normal chromosomes, such probes label a contiguous stretch of DNA and produce a single hybridization domain per chromosome in interphase cells. The translocation disrupts the hybridization domain and the resulting two fragments appear as physically separated hybridization domains in

  8. A Single Phase Doubly Grounded Semi-Z-Source Inverter for Photovoltaic (PV Systems with Maximum Power Point Tracking (MPPT

    Directory of Open Access Journals (Sweden)

    Tofael Ahmed

    2014-06-01

    Full Text Available In this paper, a single phase doubly grounded semi-Z-source inverter with maximum power point tracking (MPPT is proposed for photovoltaic (PV systems. This proposed system utilizes a single-ended primary inductor (SEPIC converter as DC-DC converter to implement the MPPT algorithm for tracking the maximum power from a PV array and a single phase semi-Z-source inverter for integrating the PV with AC power utilities. The MPPT controller utilizes a fast-converging algorithm to track the maximum power point (MPP and the semi-Z-source inverter utilizes a nonlinear SPWM to produce sinusoidal voltage at the output. The proposed system is able to track the MPP of PV arrays and produce an AC voltage at its output by utilizing only three switches. Experimental results show that the fast-converging MPPT algorithm has fast tracking response with appreciable MPP efficiency. In addition, the inverter shows the minimization of common mode leakage current with its ground sharing feature and reduction of the THD as well as DC current components at the output during DC-AC conversion.

  9. Fast computation of quadrupole and hexadecapole approximations in microlensing with a single point-source evaluation

    Science.gov (United States)

    Cassan, Arnaud

    2017-07-01

    The exoplanet detection rate from gravitational microlensing has grown significantly in recent years thanks to a great enhancement of resources and improved observational strategy. Current observatories include ground-based wide-field and/or robotic world-wide networks of telescopes, as well as space-based observatories such as satellites Spitzer or Kepler/K2. This results in a large quantity of data to be processed and analysed, which is a challenge for modelling codes because of the complexity of the parameter space to be explored and the intensive computations required to evaluate the models. In this work, I present a method that allows to compute the quadrupole and hexadecapole approximations of the finite-source magnification with more efficiency than previously available codes, with routines about six times and four times faster, respectively. The quadrupole takes just about twice the time of a point-source evaluation, which advocates for generalizing its use to large portions of the light curves. The corresponding routines are available as open-source python codes.

  10. On the estimation of the current density in space plasmas: Multi- versus single-point techniques

    Science.gov (United States)

    Perri, Silvia; Valentini, Francesco; Sorriso-Valvo, Luca; Reda, Antonio; Malara, Francesco

    2017-06-01

    Thanks to multi-spacecraft mission, it has recently been possible to directly estimate the current density in space plasmas, by using magnetic field time series from four satellites flying in a quasi perfect tetrahedron configuration. The technique developed, commonly called ;curlometer; permits a good estimation of the current density when the magnetic field time series vary linearly in space. This approximation is generally valid for small spacecraft separation. The recent space missions Cluster and Magnetospheric Multiscale (MMS) have provided high resolution measurements with inter-spacecraft separation up to 100 km and 10 km, respectively. The former scale corresponds to the proton gyroradius/ion skin depth in ;typical; solar wind conditions, while the latter to sub-proton scale. However, some works have highlighted an underestimation of the current density via the curlometer technique with respect to the current computed directly from the velocity distribution functions, measured at sub-proton scales resolution with MMS. In this paper we explore the limit of the curlometer technique studying synthetic data sets associated to a cluster of four artificial satellites allowed to fly in a static turbulent field, spanning a wide range of relative separation. This study tries to address the relative importance of measuring plasma moments at very high resolution from a single spacecraft with respect to the multi-spacecraft missions in the current density evaluation.

  11. Ambiguity resolution in precise point positioning with hourly data for global single receiver

    Science.gov (United States)

    Zhang, Xiaohong; Li, Pan; Guo, Fei

    2013-01-01

    Integer ambiguity resolution (IAR) can improve precise point positioning (PPP) performance significantly. IAR for PPP became a highlight topic in global positioning system (GPS) community in recent years. More and more researchers focus on this issue. Progress has been made in the latest years. In this paper, we aim at investigating and demonstrating the performance of a global zero-differenced (ZD) PPP IAR service for GPS users by providing routine ZD uncalibrated fractional offsets (UFOs) for wide-lane and narrow-lane. Data sets from all IGS stations collected on DOY 1, 100, 200 and 300 of 2010 are used to validate and demonstrate this global service. Static experiment results show that an accuracy better than 1 cm in horizontal and 1-2 cm in vertical could be achieved in ambiguity-fixed PPP solution with only hourly data. Compared with PPP float solution, an average improvement reaches 58.2% in east, 28.3% in north and 23.8% in vertical for all tested stations. Results of kinematic experiments show that the RMS of kinematic PPP solutions can be improved from 21.6, 16.6 and 37.7 mm to 12.2, 13.3 and 34.3 mm for the fixed solutions in the east, north and vertical components, respectively. Both static and kinematic experiments show that wide-lane and narrow-lane UFO products of all satellites can be generated and provided in a routine way accompanying satellite orbit and clock products for the PPP user anywhere around the world, to obtain accurate and reliable ambiguity-fixed PPP solutions.

  12. Channel capacity of TDD-OFDM-MIMO for multiple access points in a wireless single-frequency-network

    DEFF Research Database (Denmark)

    Takatori, Y.; Fitzek, Frank; Tsunekawa, K.

    2005-01-01

    MIMO data transmission scheme, which combines Single-Frequency-Network (SFN) with TDD-OFDM-MIMO applied for wireless LAN networks. In our proposal, we advocate to use SFN for multiple access points (MAP) MIMO data transmission. The goal of this approach is to achieve very high channel capacity in both...... LOS and non line of sight (NLOS) environments. The channel capacity of the proposed method is derived for the direct path environments and it confirms the effectiveness of the proposed scheme in the LOS scenario. Moreover, solid computer simulation results confirm the effectiveness of the proposed...

  13. Theoretical Basis for Stochastic Optimization Starting from a Single Point in the Search Space Formed by Real DNA Molecules

    Science.gov (United States)

    Someya, Hiroshi; Yamamura, Masayuki; Sakamoto, Kensaku

    This paper discusses DNA-based stochastic optimizations under the constraint that the search starts from a given point in a search space. Generally speaking, a stochastic optimization method explores a search space and finds out the optimum or a sub-optimum after many cycles of trials and errors. This search process could be implemented efficiently by ``molecular computing'', which processes DNA molecules by the techniques of molecular biology to generate and evaluate a vast number of solution candidates at a time. We assume the exploration starting from a single point, and propose a method to embody DNA-based optimization under this constraint, because this method has a promising application in the research field of protein engineering. In this application, a string of nucleotide bases (a base sequence) encodes a protein possessing a specific activity, which could be given as a value of an objective function. Thus, a problem of obtaining a protein with the optimum or a sub-optimum about the desired activity corresponds to a combinatorial problem of obtaining a base sequence giving the optimum or a sub-optimum in the sequence space. Biologists usually modify a base sequence corresponding to a naturally occurring protein into another sequence giving a desired activity. In other words, they explore the space in the proximity of a natural protein as a start point. We first examined if the optimization methods that involve a single start point, such as simulated annealing, Gibbs sampler, and MH algorithms, can be implemented by DNA-based operations. Then, we proposed an application of genetic algorithm, and examined the performance of this application on a model fitness landscape by computer experiments. These experiments gave helpful guidelines in the embodiments of DNA-based stochastic optimization, including a better design of crossover operator.

  14. Detecting shifts in gene regulatory networks during time-course experiments at single-time-point temporal resolution.

    Science.gov (United States)

    Takenaka, Yoichi; Seno, Shigeto; Matsuda, Hideo

    2015-10-01

    Comprehensively understanding the dynamics of biological systems is one of the greatest challenges in biology. Vastly improved biological technologies have provided vast amounts of information that must be understood by bioinformatics and systems biology researchers. Gene regulations have been frequently modeled by ordinary differential equations or graphical models based on time-course gene expression profiles. The state-of-the-art computational approaches for analyzing gene regulations assume that their models are same throughout time-course experiments. However, these approaches cannot easily analyze transient changes at a time point, such as diauxic shift. We propose a score that analyzes the gene regulations at each time point. The score is based on the information gains of information criterion values. The method detects the shifts in gene regulatory networks (GRNs) during time-course experiments with single-time-point resolution. The effectiveness of the method is evaluated on the diauxic shift from glucose to lactose in Escherichia coli. Gene regulation shifts were detected at two time points: the first corresponding to the time at which the growth of E. coli ceased and the second corresponding to the end of the experiment, when the nutrient sources (glucose and lactose) had become exhausted. According to these results, the proposed score and method can appropriately detect the time of gene regulation shifts. The method based on the proposed score provides a new tool for analyzing dynamic biological systems. Because the score value indicates the strength of gene regulation at each time point in a gene expression profile, it can potentially infer hidden GRNs from time-course experiments.

  15. Ten-year survival and prognostic markers in one thousand patients with advanced heart failure. A single-centre analysis.

    Science.gov (United States)

    Lesny, Peter; Luknar, Milan; Matejka, Martin; Varga, Ivan; Solik, Peter; Wimmerova, Sona; Goncalvesova, Eva

    2016-06-01

    Patients with advanced heart failure (HF) represent a pool of candidates for heart transplantation and long-term mechanical circulatory support devices. The aim of our study was to determine simple and reliable markers of one-year mortality for selection of the most suitable patients for heart replacement therapy. One thousand consecutive patients with HF (mean age 49 ± 10.9 years; 86.8% males) referred to a single tertiary centre from January 1998 to January 2010 in order to assess the indication for heart transplantation were enrolled. Kaplan-Meier survival analysis was performed. Independent mortality predictors were established using logistic regression analysis. The mean follow-up was 4.3 ± 2.7 years (range 1-12 years). Cumulative survival was as follows: 1-year survival 83%, 3-year 63%, 5-year 50%, 7-year 39%, and 10-year 23%. Independent predictors of 1-year mortality included coronary artery disease, left ventricular diastolic diameter >79 mm, plasma sodium 240 mg/day. Short-term prognosis of HF patient can be estimated based on simple parameters. Patients with signs of poor prognosis should be referred to tertiary centres to be considered for heart replacement therapy.

  16. The evolution of IRRR nuclear standards from the single failure criterion and their impact on system design

    International Nuclear Information System (INIS)

    Clark, D.H.

    1978-01-01

    One of the first industry standards developed in the United States to meet regulatory agency criteria for the design and installation of nuclear power plant control and instrumentation systems was prepared by the Institute of Electrical and Electronics Engineers, Inc., abbreviated IEEE. This was IEEE Std. 279, first issued in 1968. It was subsequently revised and reissued as IEEE Std. 279-1971 ''IEEE Standard: Criteria for Protection Systems for Nuclear Power Generating Stations''. Not only has the implementation of this standard had a tremendous impact on nuclear power plant design in the United States, it has been the base document from which subsequent IEEE nuclear standards have been developed. Three major concepts which are addressed by IEEE 279, and which have had a major impact upon control and instrumentation systems in nuclear power plants are the following : 1) Single failure criterion. 2) Equipment qualification. 3) Channel independence. Each of these concepts has resulted in the development of subsequent IEEE Nuclear Standards. The impact of some of these on control and instrumentation systems are discussed. (author)

  17. Enhancement of the point defect pinning effect in Mo-doped Bi2212 single crystals of reduced anisotropy

    CERN Document Server

    Han, S H; Dai, Y; Zhang, Y; Zhang, H; Zhao, Y

    2002-01-01

    High quality Bi sub 2 Sr sub 2 CaCu sub 2 sub - sub x Mo sub x O sub y (x = 0, 0.01 and 0.02) single crystals have been grown by a self-flux method in a horizontal temperature gradient and their flux pinning and irreversibility behaviour have been investigated. The irreversibility lines of the undoped and Mo-doped Bi2212 crystals have been greatly improved by reducing the anisotropy parameter gamma. However, this improvement is much more pronounced for Mo-doped crystals than for the undoped ones. The peak effect of magnetization loops also changes with both Mo-doping and gamma. The results provide strong evidence that the point defect pinning served by Mo is greatly enhanced when the anisotropy of the system is reduced.

  18. High performance control strategy for single-phase three-level neutral-point-clamped traction four-quadrant converters

    DEFF Research Database (Denmark)

    Kejian, Song; Konstantinou, Georgios; Jing, Li

    2017-01-01

    multiple unit traction system is proposed in this study. The strategy is based on a multiple frequency tuned quasi-proportional resonant controller in the ac-side current loop and a multiple frequency tuned notch filter in the dc-link voltage loop. Under the typical supply voltage distortion present......Operational data from Chinese railways indicate a number of challenges for traction four-quadrant converter (4QC) control including low-order voltage and current harmonics and reference tracking. A control strategy for a single-phase three-level neutral-point-clamped 4QC employed in the electric...... in the network, the proposed control strategy improves the current tracking performance and reduces the line current harmonics, when compared with conventional control strategies. Experimental results, both under purely sinusoidal and distorted supply voltages, validate the effectiveness of the proposed control...

  19. Experimental and numerical study on optimization of the single point incremental forming of AINSI 304L stainless steel sheet

    Science.gov (United States)

    Saidi, B.; Giraud-Moreau, L.; Cherouat, A.; Nasri, R.

    2017-09-01

    AINSI 304L stainless steel sheets are commonly formed into a variety of shapes for applications in the industrial, architectural, transportation and automobile fields, it’s also used for manufacturing of denture base. In the field of dentistry, there is a need for personalized devises that are custom made for the patient. The single point incremental forming process is highly promising in this area for manufacturing of denture base. The single point incremental forming process (ISF) is an emerging process based on the use of a spherical tool, which is moved along CNC controlled tool path. One of the major advantages of this process is the ability to program several punch trajectories on the same machine in order to obtain different shapes. Several applications of this process exist in the medical field for the manufacturing of personalized titanium prosthesis (cranial plate, knee prosthesis...) due to the need of product customization to each patient. The objective of this paper is to study the incremental forming of AISI 304L stainless steel sheets for future applications in the dentistry field. During the incremental forming process, considerable forces can occur. The control of the forming force is particularly important to ensure the safe use of the CNC milling machine and preserve the tooling and machinery. In this paper, the effect of four different process parameters on the maximum force is studied. The proposed approach consists in using an experimental design based on experimental results. An analysis of variance was conducted with ANOVA to find the input parameters allowing to minimize the maximum forming force. A numerical simulation of the incremental forming process is performed with the optimal input process parameters. Numerical results are compared with the experimental ones.

  20. Investigating the use of multi-point coupling for single-sensor bearing estimation in one direction

    Science.gov (United States)

    Woolard, Americo G.; Phoenix, Austin A.; Tarazaga, Pablo A.

    2018-04-01

    Bearing estimation of radially propagating symmetric waves in solid structures typically requires a minimum of two sensors. As a test specimen, this research investigates the use of multi-point coupling to provide directional inference using a single-sensor. By this provision, the number of sensors required for localization can be reduced. A finite-element model of a beam is constructed with a symmetrically placed bipod that has asymmetric joint-stiffness properties. Impulse loading is applied at different points along the beam, and measurements are taken from the apex of the bipod. A technique is developed to determine the direction-of-arrival of the propagating wave. The accuracy when using the bipod with the developed technique is compared against results gathered without the bipod and measuring from an asymmetric location along the beam. The results show 92% accuracy when the bipod is used, compared to 75% when measuring without the bipod from an asymmetric location. A geometry investigation finds the best accuracy results when one leg of the bipod has a low stiffness and a large diameter relative to the other leg.

  1. Single-Point Incremental Forming of Two Biocompatible Polymers: An Insight into Their Thermal and Structural Properties

    Directory of Open Access Journals (Sweden)

    Luis Marcelo Lozano-Sánchez

    2018-04-01

    Full Text Available Sheets of polycaprolactone (PCL and ultra-high molecular weight polyethylene (UHMWPE were fabricated and shaped by the Single-Point Incremental Forming process (SPIF. The performance of these biocompatible polymers in SPIF was assessed through the variation of four main parameters: the diameter of the forming tool, the spindle speed, the feed rate, and the step size based on a Box–Behnken design of experiments of four variables and three levels. The design of experiments allowed us to identify the parameters that most affect the forming of PCL and UHMWPE. The study was completed by means of a deep characterization of the thermal and structural properties of both polymers. These properties were correlated to the performance of the polymers observed in SPIF, and it was found that the polymer chains are oriented as a consequence of the SPIF processing. Moreover, by X-ray diffraction it was proved that polymer chains behave differently on each surface of the fabricated parts, since the chains on the surface in contact with the forming tool are oriented horizontally, while on the opposite surface they are oriented in the vertical direction. The unit cell of UHMWPE is distorted, passing from an orthorhombic cell to a monoclinic due to the slippage between crystallites. This slippage between crystallites was observed in both PCL and UHMWPE, and was identified as an alpha star thermal transition located in the rubbery region between the glass transition and the melting point of each polymer.

  2. Retrospective analysis of 56 edentulous dental arches restored with 344 single-stage implants using an immediate loading fixed provisional protocol: statistical predictors of implant failure.

    Science.gov (United States)

    Kinsel, Richard P; Liss, Mindy

    2007-01-01

    The purpose of this retrospective study was to evaluate the effects of implant dimensions, surface treatment, location in the dental arch, numbers of supporting implant abutments, surgical technique, and generally recognized risk factors on the survival of a series of single-stage Straumann dental implants placed into edentulous arches using an immediate loading protocol. Each patient received between 4 and 18 implants in one or both dental arches. Periapical radiographs were obtained over a 2- to 10-year follow-up period to evaluate crestal bone loss following insertion of the definitive metal-ceramic fixed prostheses. Univariate tests for failure rates as a function of age ( or = 60 years), gender, smoking, bone grafting, dental arch, surface type, anterior versus posterior, number of implants per arch, and surgical technique were made using Fisher exact tests. The Cochran-Armitage test for trend was used to evaluate the presence of a linear trend in failure rates regarding implant length and implant diameter. Logistic regression modeling was used to determine which, if any, of the aforementioned factors would predict patient and implant failure. A significance criterion of P = .05 was utilized. Data were collected for 344 single-stage implants placed into 56 edentulous arches (39 maxillae and 17 mandibles) of 43 patients and immediately loaded with a 1-piece provisional fixed prosthesis. A total of 16 implants failed to successfully integrate, for a survival rate of 95.3%. Increased rates of failure were associated with reduced implant length, placement in the posterior region of the jaw, increased implant diameter, and surface treatment. Implant length emerged as the sole significant predictor of implant failure. In this retrospective analysis of 56 consecutively treated edentulous arches with multiple single-stage dental implants loaded immediately, reduced implant length was the sole significant predictor of failure.

  3. Patterns of Failure Following Multimodal Treatment for Medulloblastoma: Long-Term Follow-up Results at a Single Institution.

    Science.gov (United States)

    Lee, Dong Soo; Cho, Jaeho; Kim, Se Hoon; Kim, Dong-Seok; Shim, Kyu Won; Lyu, Chuhl Joo; Han, Jung Woo; Suh, Chang-Ok

    2015-10-01

    The purpose of this study is to investigate the long-term results and appropriateness of radiation therapy (RT) for medulloblastoma (MB) at a single institution. We analyzed the clinical outcomes of 106 patients with MB who received RT between January 1992 and October 2009. The median age was 7 years (range, 0 to 50 years), and the proportion of M0, M1, M2, and M3 stages was 60.4%, 8.5%, 4.7%, and 22.6%, respectively. The median total craniospinal irradiation (CSI) and posterior fossa tumor bed dose in 102 patients (96.2%) treated with CSI was 36 Gy and 54 Gy, respectively. The median follow-up period in survivors was 132 months (range, 31 to 248 months). A gradual improvement in survival outcomes was observed, with 5-year overall survival rates of 61.5% in 1990s increasing to 73.6% in 2000s. A total of 29 recurrences (27.4%) developed at the following sites: five (17.2%) in the tumor bed; five (17.2%) in the posterior fossa other than the tumor bed; nine (31%) in the supratentorium; and six (20.7%) in the spinal subarachnoid space only. The four remaining patients showed multiple site recurrences. Among 12 supratentorial recurrences, five cases recurred in the subfrontal areas. Although the frequency of posterior fossa/tumor bed recurrences was significantly high among patients treated with subtotal resection, other site (other intracranial/spinal) recurrences were more common among patients treated with gross tumor removal (p=0.016). There was no case of spinal subarachnoid space relapse from desmoplastic/extensive nodular histological subtypes. Long-term follow-up results and patterns of failure confirmed the importance of optimal RT dose and field arrangement. More tailored multimodal strategies and proper CSI technique may be the cornerstones for improving treatment outcomes in MB patients.

  4. Bayesian framework for prediction of future number of failures from a single group of units in the field

    International Nuclear Information System (INIS)

    Ebrahimi, Nader

    2009-01-01

    This paper considers prediction of unknown number of failures in a future inspection of a group of in-service units based on number of failures observed from an earlier inspection. We develop a flexible Bayesian model and calculate Bayesian estimator for this unknown number and other quantities of interest. The paper also includes an illustration of our method in an example about heat exchanger. A main advantage of our approach is in its nonparametric nature. By nonparametric here we simply mean that no assumption is required about the failure time distribution of a unit

  5. Point-of-Care Determination of Acetaminophen Levels with Multi-Hydrogen Bond Manipulated Single-Molecule Recognition (eMuHSiR).

    Science.gov (United States)

    Zhang, Yan; Huang, Zhongyuan; Wang, Letao; Wang, Chunming; Zhang, Changde; Wiese, Tomas; Wang, Guangdi; Riley, Kevin; Wang, Zhe

    2018-04-03

    This work aims to face the challenge of monitoring small molecule drugs accurately and rapidly for point-of-care (POC) diagnosis in current clinical settings. Overdose of acetaminophen (AP), a commonly used over the counter (OTC) analgesic drug, has been determined to be a major cause of acute liver failure in the US and the UK. However, there is no rapid and accurate detection method available for this drug in the emergency room. The present study examined an AP sensing strategy that relies on a previously unexplored strong interaction between AP and the arginine (Arg) molecule. It was found that as many as 4 hydrogen bonds can be formed between one Arg molecule and one AP molecule. By taking advantages of this structural selectivity and high tenability of hydrogen bonds, Arg, immobilized on a graphene surface via electrostatic interactions, was utilized to structurally capture AP. Interestingly, bonded AP still remained the perfect electrochemical activities. The extent of Arg-AP bonds was quantified using a newly designed electrochemical (EC) sensor. To verify the feasibility of this novel assay, based on multihydrogen bond manipulated single-molecule recognition (eMuHSiR), both pharmaceutical and serum sample were examined. In commercial tablet measurement, no significant difference was seen between the results of eMuHSiR and other standard methods. For measuring AP concentration in the mice blood, the substances in serum, such as sugars and fats, would not bring any interference to the eMuHSiR in a wide concentration range. This eMuHSiR method opens the way for future development of small molecule detection for the POC testing.

  6. The ADOPT trial (Assessment of Efficacies of Cardiac Resynchronization Therapies (CRT-P/D for Heart Failure Patients in China: rationale, design, and end-points

    Directory of Open Access Journals (Sweden)

    Liu B

    2011-06-01

    agree, after re-evaluation of the baseline situation, they may enter into Group for Selection again. Since patients know they already have a device implant and the examiners are aware of the grouping of the patients after seeing the incision scar and post-implant electrocardiogram, this study is of open-label design; however the executive committee will be kept blind when making event-adjudication. Results: Prospectively defined primary end-points for the study include combined all-cause mortality and hospitalizations. A variety of secondary end-points will further define the efficacy and mechanism(s of action of CRT in CHF. The last date of the study shall be the day after 24 months of follow-up of the last enrolled patient. Recruitment is expected to be completed at the end of 2011 and the study should close at the beginning of 2014.Conclusion: The ADOPT trial will evaluate the effects of CRT on Chinese CHF patients and provide related research data for Chinese CHF patients who may need CRT.Keywords: heart failure, clinical trial, biventricular pacing, cardiac device

  7. Evaluation of mixing downstream of tees in duct systems with respect to single point representative air sampling.

    Science.gov (United States)

    Kim, Taehong; O'Neal, Dennis L; Ortiz, Carlos

    2006-09-01

    Air duct systems in nuclear facilities must be monitored with continuous sampling in case of an accidental release of airborne radionuclides. The purpose of this work is to identify the air sampling locations where the velocity and contaminant concentrations fall below the 20% coefficient of variation required by the American National Standards Institute/Health Physics Society N13.1-1999. Experiments of velocity and tracer gas concentration were conducted on a generic "T" mixing system which included combinations of three sub ducts, one main duct, and air velocities from 0.5 to 2 m s (100 to 400 fpm). The experimental results suggest that turbulent mixing provides the accepted velocity coefficients of variation after 6 hydraulic diameters downstream of the T-junction. About 95% of the cases achieved coefficients of variation below 10% by 6 hydraulic diameters. However, above a velocity ratio (velocity in the sub duct/velocity in the main duct) of 2, velocity profiles were uniform in a shorter distance downstream of the T-junction as the velocity ratio went up. For the tracer gas concentration, the distance needed for the coefficients of variation to drop 20% decreased with increasing velocity ratio due to the sub duct airflow momentum. The results may apply to other duct systems with similar geometries and, ultimately, be a basis for selecting a proper sampling location under the requirements of single point representative sampling.

  8. Role of single-point mutations and deletions on transition temperatures in ideal proteinogenic heteropolymer chains in the gas phase.

    Science.gov (United States)

    Olivares-Quiroz, L

    2016-07-01

    A coarse-grained statistical mechanics-based model for ideal heteropolymer proteinogenic chains of non-interacting residues is presented in terms of the size K of the chain and the set of helical propensities [Formula: see text] associated with each residue j along the chain. For this model, we provide an algorithm to compute the degeneracy tensor [Formula: see text] associated with energy level [Formula: see text] where [Formula: see text] is the number of residues with a native contact in a given conformation. From these results, we calculate the equilibrium partition function [Formula: see text] and characteristic temperature [Formula: see text] at which a transition from a low to a high entropy states is observed. The formalism is applied to analyze the effect on characteristic temperatures [Formula: see text] of single-point mutations and deletions of specific amino acids [Formula: see text] along the chain. Two probe systems are considered. First, we address the case of a random heteropolymer of size K and given helical propensities [Formula: see text] on a conformational phase space. Second, we focus our attention to a particular set of neuropentapeptides, [Met-5] and [Leu-5] enkephalins whose thermodynamic stability is a key feature on their coupling to [Formula: see text] and [Formula: see text] receptors and the triggering of biochemical responses.

  9. Influence of Fiber Orientation on Single-Point Cutting Fracture Behavior of Carbon-Fiber/Epoxy Prepreg Sheets

    Directory of Open Access Journals (Sweden)

    Yingying Wei

    2015-10-01

    Full Text Available The purpose of this article is to investigate the influences of carbon fibers on the fracture mechanism of carbon fibers both in macroscopic view and microscopic view by using single-point flying cutting method. Cutting tools with three different materials were used in this research, namely, PCD (polycrystalline diamond tool, CVD (chemical vapor deposition diamond thin film coated carbide tool and uncoated carbide tool. The influence of fiber orientation on the cutting force and fracture topography were analyzed and conclusions were drawn that cutting forces are not affected by cutting speeds but significantly influenced by the fiber orientation. Cutting forces presented smaller values in the fiber orientation of 0/180° and 15/165° but the highest one in 30/150°. The fracture mechanism of carbon fibers was studied in different cutting conditions such as 0° orientation angle, 90° orientation angle, orientation angles along fiber direction, and orientation angles inverse to the fiber direction. In addition, a prediction model on the cutting defects of carbon fiber reinforced plastic was established based on acoustic emission (AE signals.

  10. Accurate mitochondrial DNA sequencing using off-target reads provides a single test to identify pathogenic point mutations.

    Science.gov (United States)

    Griffin, Helen R; Pyle, Angela; Blakely, Emma L; Alston, Charlotte L; Duff, Jennifer; Hudson, Gavin; Horvath, Rita; Wilson, Ian J; Santibanez-Koref, Mauro; Taylor, Robert W; Chinnery, Patrick F

    2014-12-01

    Mitochondrial disorders are a common cause of inherited metabolic disease and can be due to mutations affecting mitochondrial DNA or nuclear DNA. The current diagnostic approach involves the targeted resequencing of mitochondrial DNA and candidate nuclear genes, usually proceeds step by step, and is time consuming and costly. Recent evidence suggests that variations in mitochondrial DNA sequence can be obtained from whole-exome sequence data, raising the possibility of a comprehensive single diagnostic test to detect pathogenic point mutations. We compared the mitochondrial DNA sequence derived from off-target exome reads with conventional mitochondrial DNA Sanger sequencing in 46 subjects. Mitochondrial DNA sequences can be reliably obtained using three different whole-exome sequence capture kits. Coverage correlates with the relative amount of mitochondrial DNA in the original genomic DNA sample, heteroplasmy levels can be determined using variant and total read depths, and-providing there is a minimum read depth of 20-fold-rare sequencing errors occur at a rate similar to that observed with conventional Sanger sequencing. This offers the prospect of using whole-exome sequence in a diagnostic setting to screen not only all protein coding nuclear genes but also all mitochondrial DNA genes for pathogenic mutations. Off-target mitochondrial DNA reads can also be used to assess quality control and maternal ancestry, inform on ethnic origin, and allow genetic disease association studies not previously anticipated with existing whole-exome data sets.

  11. Comparison of plastic strains on AA5052 by single point incremental forming process using digital image processing

    Energy Technology Data Exchange (ETDEWEB)

    Mugendiran, V.; Gnanavelbabu, A. [Anna University, Chennai, Tamilnadu (India)

    2017-06-15

    In this study, a surface based strain measurement was used to determine the formability of the sheet metal. A strain measurement may employ manual calculation of plastic strains based on the reference circle and the deformed circle. The manual calculation method has a greater margin of error in the practical applications. In this paper, an attempt has been made to compare the formability by implementing three different theoretical approaches: Namely conventional method, least square method and digital based strain measurements. As the sheet metal was formed by a single point incremental process the etched circles get deformed into elliptical shapes approximately, image acquisition has been done before and after forming. The plastic strains of the deformed circle grids are calculated based on the non- deformed reference. The coordinates of the deformed circles are measured by various image processing steps. Finally the strains obtained from the deformed circle are used to plot the forming limit diagram. To evaluate the accuracy of the system, the conventional, least square and digital based method of prediction of the forming limit diagram was compared. Conventional method and least square method have marginal error when compared with digital based processing method. Measurement of strain based on image processing agrees well and can be used to improve the accuracy and to reduce the measurement error in prediction of forming limit diagram.

  12. PIV study of non-Marangoni surface flows in thin liquid films induced by single- and multi-point thermodes

    Science.gov (United States)

    Cui, Nai-Yi; Wang, Song-Po

    2018-03-01

    The non-Marangoni directional flows, which can occur in only very thin liquid films, have been studied using particle image velocimetry techniques. Single- and multi-point thermodes have been used in this study for generating the flows. The results show that the direction of these flows is governed by the variation trend of the thickness of the film and the shape of the temperature profile. A hot thermode always drives a thick-to-thin flow, whereas a cold thermode always drives a flow in the opposite direction. Increasing the temperature difference between the thermode and the ambience, or decreasing the thickness of the liquid film, can accelerate the flow speed. However, the flow speed cannot exceed an upper limit. When more than one thermode was used, different flow patterns, including thick-to-thin streams driven by hot thermodes and thin-to-thick streams driven by cold thermodes, could be formed. The experimental results strongly suggest that these flows were not driven by thermo-capillary forces but by a newly proposed thermo-dynamic mechanism.

  13. Congestive heart failure is associated with lipoprotein components in statin-treated patients with coronary heart disease Insights from the Incremental Decrease in End points Through Aggressive Lipid Lowering Trial (IDEAL)

    DEFF Research Database (Denmark)

    Holme, Ingar; Strandberg, Timo E; Faergeman, Ole

    2009-01-01

    BACKGROUND: Very few, if any, studies have assessed the ability of apolipoproteins to predict new-onset of congestive heart failure (HF) in statin-treated patients with coronary heart disease (CHD). AIMS: To employ the Incremental Decrease in End points Through Aggressive Lipid Lowering Trial...... with the occurrence of new-onset HF. Variables related to low-density lipoprotein cholesterol (LDL-C) carried less predictive information than those related to high-density lipoprotein cholesterol (HDL-C), and apoA-1 was the single variable most strongly associated with HF. LDL-C was less predictive than both non......-HDL-C (total cholesterol minus HDL-C) and apoB. The ratio of apoB to apoA-1 was most strongly related to HF after adjustment for potential confounders, among which diabetes had a stronger correlation with HF than did hypertension. ApoB/apoA-1 carried approximately 2.2 times more of the statistical information...

  14. Mechanical performance of a screw-type veterinary suture anchor subjected to single load to failure and cyclic loads.

    Science.gov (United States)

    Balara, Jason M; McCarthy, Robert J; Boudrieau, Randy J; Kraus, Karl H

    2004-01-01

    To characterize the mechanical performance of a veterinary bone anchor under static and cyclic loads. Mechanical testing study. Cadaveric canine humeri. Humeri (6 pairs) were collected from skeletally mature dogs (mean [+/-SD] age, 17.2+/-2.1 months; weight, 20.8+/-1.5 kg). Bone anchors were inserted in the proximal metaphysis using nylon, and were longitudinally extracted. For the opposite humerus, anchors were subjected to longitudinal cyclic load (50% of the load at failure of their pair) for 1200 cycles then longitudinally loaded to failure. Anchors were then installed in a similar and adjacent area of these 2(nd) humeri with nylon and cyclically tested perpendicular to the axis of anchor insertion (100% of the longitudinal holding power of their pair) for 1200 cycles, then perpendicularly loaded to failure. Paired t-tests were used to compare holding power before and after longitudinal cyclic testing. Longitudinal holding power of the screw-type anchor in the proximal humerus was 385+/-30 N. Anchor pullout was the only mode of failure. Anchors in the paired humeri did not fail after 1200 cycles of 50% longitudinal loading, and post-cycle holding strength was not different (335+/-87 N; P=.32). Perpendicularly loaded anchors did not fail after 1200 cycles of 100% of opposite longitudinal holding strength, and had post-cycle perpendicular holding strengths of 514+/-72 N. Suture breakage was the mode of failure. Bone anchor holding strength is dependent on orientation of suture load. Screw-type bone anchor holding strength was not affected by longitudinal cyclic loading, and holding strengths of approximately 385 N can be expected in metaphyseal bone of large-breed mature dogs. Perpendicularly loaded anchors have higher failure loads, and holding strength of approximately 514 N can be expected in metaphyseal bone of the proximal humerus.

  15. Multiple enhanced self-protected spanning trees based architecture for recovery from single failure in metro ethernet

    Science.gov (United States)

    Li, Yong; Chen, Wentao; Jin, Depeng; Su, Li; Zeng, Lieguang

    2008-11-01

    Carriers and service providers are rushing to provide Ethernet-based virtual private network services in metro area network (MAN) as the most cost effective way to address the needs of the enterprise network market. To address the fast recovery from any signal failure issue in the Metro Ethernet, we propose a metro Ethernet architecture based on multiple Enhanced Self-protected Spanning Trees (ESST). The recovery mechanism, named Birthday-based Link Replacing Mechanism (BLRM), in this architecture is able to transform a self-protected spanning tree into another spanning tree after any signal link or node failure. Simulation result demonstrates the effectiveness of the BLRM in achieving fast recovery.

  16. Heart failure in patients with sick sinus syndrome treated with single lead atrial or dual-chamber pacing

    DEFF Research Database (Denmark)

    Riahi, Sam; Nielsen, Jens Cosedis; Hjortshøj, Søren

    2012-01-01

    AIMS: Previous studies indicate that ventricular pacing may precipitate heart failure (HF). We investigated occurrence of HF during long-term follow-up among patients with sick sinus syndrome (SSS) randomized to AAIR or DDDR pacing. Furthermore, we investigated effects of percentage of ventricular...... during follow-up. Patients were classified with new HF, if in New York Heart Association (NYHA) functional class IV or if presence of ≥2 of: oedema; dyspnoea; NYHA functional class III. Mean follow-up was 5.4 ± 2.4 years. Heart failure hospitalizations did not differ between groups. In the AAIR group...

  17. Low-pressure, single-point grout injection for tank heel sludge mixing and in-situ immobilization

    International Nuclear Information System (INIS)

    Whyatt, G.A.; Hymas, C.R.

    1998-09-01

    This report describes tests conducted in an approximately 9-ft diameter test tank situated outside the 336 building in Hanford's 300 area. The tests were performed to measure the ability of jets of grout slurry to mobilize and mix simulated tank sludge. The technique is intended for in situ immobilization of tank waste heels. The current approach uses a single, rotated, larger-diameter nozzle driven at lower pressure. Due to the larger diameter, the potential for plugging is reduced and the effective radius around an injection point over which the jet is effective in mobilizing sludge from the tank bottom can be made larger. A total of three grout injection tests were conducted in a 9-ft diameter tank. In each case, a 2-in. layer of kaolin clay paste was placed on a dry tank floor to simulate a sludge heel. The clay was covered with 4 inches of water. The grout slurry, consisting of Portland cement, class F fly ash, and eater, was prepared and delivered by an offsite vendor. In the third test, the sludge in half of the tank was replaced by a layer of 20x50 mesh zeolite, and bentonite clay was added to the grout formulation. After injection, the grout was allowed to set and then the entire grout monolith was manually broken up and excavated using a jack hammer. Intact pieces of clay were visually apparent due to a sharp color contrast between the grout and clay. Remaining clay deposits were collected and weighed and suspended clay pieces within the monolith were photographed. The mobilization performance of the grout jets exceeded expectations

  18. Van Allen Probes Science Gateway: Single-Point Access to Long-Term Radiation Belt Measurements and Space Weather Nowcasting

    Science.gov (United States)

    Romeo, G.; Barnes, R. J.; Ukhorskiy, A. Y.; Sotirelis, T.; Stephens, G.

    2017-12-01

    The Science Gateway gives single-point access to over 4.5 years of comprehensive wave and particle measurements from the Van Allen Probes NASA twin-spacecraft mission. The Gateway provides a set of visualization and data analysis tools including: HTML5-based interactive visualization of high-level data products from all instrument teams in the form of: line plots, orbital content plots, dynamical energy spectra, L-shell context plots (including two-spacecraft plotting), FFT spectra of wave data, solar wind and geomagnetic indices data, etc.; download custom multi-instrument CDF data files of selected data products; publication quality plots of digital data; combined orbit predicts for mission planning and coordination including: Van Allen Probes, MMS, THEMIS, Arase (ERG), Cluster, GOES, Geotail, FIREBIRD; magnetic footpoint calculator for coordination with LEO and ground-based assets; real-time computation and processing of empirical magnetic field models - computation of magnetic ephemeris, computation of adiabatic invariants. Van Allen Probes is the first spacecraft mission to provide a nowcast of the radiation environment in the heart of the radiation belts, where the radiation levels are the highest and most dangerous for spacecraft operations. For this purpose, all instruments continuously broadcast a subset of their science data in real time. Van Allen Probes partners with four foreign institutions who operate ground stations that receive the broadcast: Korea (KASI), the Czech republic (CAS), Argentina (CONAE), and Brazil (INPE). The SpWx broadcast is then collected at APL and delivered to the community via the Science Gateway.

  19. Assessment of left ventricular function with single breath-hold highly accelerated cine MRI combined with guide-point modeling

    International Nuclear Information System (INIS)

    Heilmaier, Christina; Nassenstein, Kai; Nielles-Vallespin, Sonia; Zuehlsdorff, Sven; Hunold, Peter; Barkhausen, Joerg

    2010-01-01

    Purpose: To prospectively assess the performance of highly accelerated cine MRI in multi-orientations combined with a new guide-point modeling post-processing technique (GPM approach) for assessment of left ventricular (LV) function compared to the standard summation of slices method based on a stack of short axis views (SoS approach). Materials and methods: 33 consecutive patients were examined on a 1.5 T scanner with a standard steady state free precession (SSFP) sequence (TR, 3.0 ms; TE, 1.5 m; flip angle (FA), 60 o ; acceleration factor (AF), 2) analyzed with the SoS method and a highly accelerated, single breath-hold temporal parallel acquisition SSFP sequence (TR, 4.6 ms; TE, 1.1 ms; AF, 3) post-processed with the GPM method. LV function values were measured by two independent readers with different experience in cardiac MRI and compared by using the paired t-test and F-test. Inter- and intraobserver agreements were calculated using Bland-Altman-Plots. Results: Mean acquisition and post-processing time was significantly shorter with the GPM approach (15 s/3 min versus 360 s/6 min). For all LV function parameters interobserver agreement between the experienced and non-experienced reader was significantly improved when the GPM approach was used. However, end-diastolic and end-systolic volumes were larger for the GPM technique when compared to the SoS method (P 0.121). In both readers and for all parameters variances did not differ significantly (P ≥ 0.409) and the two approaches showed an excellent linear correlation (r > 0.951). Conclusion: Due to its accurate, fast and reproducible assessment of LV function parameters highly accelerated MRI combined with the GPM technique may become the technique of first choice for assessment of LV function in clinical routine.

  20. Diagnostic accuracy of point-of-care testing for acute coronary syndromes, heart failure and thromboembolic events in primary care: a cluster-randomised controlled trial

    Directory of Open Access Journals (Sweden)

    Diemand Albert

    2011-03-01

    Full Text Available Abstract Background Evidence of the clinical benefit of 3-in-1 point-of-care testing (POCT for cardiac troponin T (cTnT, N-terminal pro-brain natriuretic peptide (NT-proBNP and D-dimer in cardiovascular risk stratification at primary care level for diagnosing acute coronary syndromes (ACS, heart failure (HF and thromboembolic events (TE is very limited. The aim of this study is to analyse the diagnostic accuracy of POCT in primary care. Methods Prospective multicentre controlled trial cluster-randomised to POCT-assisted diagnosis and conventional diagnosis (controls. Men and women presenting in 68 primary care practices in Zurich County (Switzerland with chest pain or symptoms of dyspnoea or TE were consecutively included after baseline consultation and working diagnosis. A follow-up visit including confirmed diagnosis was performed to determine the accuracy of the working diagnosis, and comparison of working diagnosis accuracy between the two groups. Results The 218 POCT patients and 151 conventional diagnosis controls were mostly similar in characteristics, symptoms and pre-existing diagnoses, but differed in working diagnosis frequencies. However, the follow-up visit showed no statistical intergroup difference in confirmed diagnosis frequencies. Working diagnoses overall were significantly more correct in the POCT group (75.7% vs 59.6%, p = 0.002, as were the working diagnoses of ACS/HF/TE (69.8% vs 45.2%, p = 0.002. All three biomarker tests showed good sensitivity and specificity. Conclusion POCT confers substantial benefit in primary care by correctly diagnosing significantly more patients. Trial registration DRKS: DRKS00000709

  1. Influence of Clinical Trial Site Enrollment on Patient Characteristics, Protocol Completion, and End Points : Insights From the ASCEND-HF Trial (Acute Study of Clinical Effectiveness of Nesiritide in Decompensated Heart Failure)

    NARCIS (Netherlands)

    Greene, Stephen J.; Hernandez, Adrian F.; Sun, Jie-Lena; Metra, Marco; Butler, Javed; Ambrosy, Andrew P.; Ezekowitz, Justin A.; Starling, Randall C.; Teerlink, John R.; Schulte, Phillip J.; Voors, Adriaan A.; Armstrong, Paul W.; O'Connor, Christopher M.; Mentz, Robert J.

    Background Most international acute heart failure trials have failed to show benefit with respect to key end points. The impact of site enrollment and protocol execution on trial performance is unclear. Methods and Results We assessed the impact of varying site enrollment volume among all 7141 acute

  2. An elevated neutrophil-lymphocyte ratio is associated with adverse outcomes following single time-point paracetamol (acetaminophen) overdose: a time-course analysis.

    Science.gov (United States)

    Craig, Darren G; Kitto, Laura; Zafar, Sara; Reid, Thomas W D J; Martin, Kirsty G; Davidson, Janice S; Hayes, Peter C; Simpson, Kenneth J

    2014-09-01

    The innate immune system is profoundly dysregulated in paracetamol (acetaminophen)-induced liver injury. The neutrophil-lymphocyte ratio (NLR) is a simple bedside index with prognostic value in a number of inflammatory conditions. To evaluate the prognostic accuracy of the NLR in patients with significant liver injury following single time-point and staggered paracetamol overdoses. Time-course analysis of 100 single time-point and 50 staggered paracetamol overdoses admitted to a tertiary liver centre. Timed laboratory samples were correlated with time elapsed after overdose or admission, respectively, and the NLR was calculated. A total of 49/100 single time-point patients developed hepatic encephalopathy (HE). Median NLRs were higher at both 72 (P=0.0047) and 96 h after overdose (P=0.0041) in single time-point patients who died or were transplanted. Maximum NLR values by 96 h were associated with increasing HE grade (P=0.0005). An NLR of more than 16.7 during the first 96 h following overdose was independently associated with the development of HE [odds ratio 5.65 (95% confidence interval 1.67-19.13), P=0.005]. Maximum NLR values by 96 h were strongly associated with the requirement for intracranial pressure monitoring (Poverdose cohort, the NLR was not associated with adverse outcomes or death/transplantation either at admission or subsequently. The NLR is a simple test which is strongly associated with adverse outcomes following single time-point, but not staggered, paracetamol overdoses. Future studies should assess the value of incorporating the NLR into existing prognostic and triage indices of single time-point paracetamol overdose.

  3. Centrifugal multiplexing fixed-volume dispenser on a plastic lab-on-a-disk for parallel biochemical single-end-point assays.

    Science.gov (United States)

    La, Moonwoo; Park, Sang Min; Kim, Dong Sung

    2015-01-01

    In this study, a multiple sample dispenser for precisely metered fixed volumes was successfully designed, fabricated, and fully characterized on a plastic centrifugal lab-on-a-disk (LOD) for parallel biochemical single-end-point assays. The dispenser, namely, a centrifugal multiplexing fixed-volume dispenser (C-MUFID) was designed with microfluidic structures based on the theoretical modeling about a centrifugal circumferential filling flow. The designed LODs were fabricated with a polystyrene substrate through micromachining and they were thermally bonded with a flat substrate. Furthermore, six parallel metering and dispensing assays were conducted at the same fixed-volume (1.27 μl) with a relative variation of ±0.02 μl. Moreover, the samples were metered and dispensed at different sub-volumes. To visualize the metering and dispensing performances, the C-MUFID was integrated with a serpentine micromixer during parallel centrifugal mixing tests. Parallel biochemical single-end-point assays were successfully conducted on the developed LOD using a standard serum with albumin, glucose, and total protein reagents. The developed LOD could be widely applied to various biochemical single-end-point assays which require different volume ratios of the sample and reagent by controlling the design of the C-MUFID. The proposed LOD is feasible for point-of-care diagnostics because of its mass-producible structures, reliable metering/dispensing performance, and parallel biochemical single-end-point assays, which can identify numerous biochemical.

  4. Fixed Points of Single- and Set-Valued Mappings in Uniformly Convex Metric Spaces with No Metric Convexity

    Directory of Open Access Journals (Sweden)

    Rafa Espínola

    2010-01-01

    Full Text Available We study the existence of fixed points and convergence of iterates for asymptotic pointwise contractions in uniformly convex metric spaces. We also study the existence of fixed points for set-valued nonexpansive mappings in the same class of spaces. Our results do not assume convexity of the metric which makes a big difference when studying the existence of fixed points for set-valued mappings.

  5. A generic-tee-plenum mixing system for application to single point aerosol sampling in stacks and ducts.

    Science.gov (United States)

    Han, Taewon; O'Neal, Dennis L; Ortiz, Carlos A

    2007-01-01

    The ANSI/HPS-N13.1-1999 standard is based on the concept of obtaining a single point representative sample from a location where the velocity and contaminant profiles are relatively uniform. It is difficult to predict the level of mixing in an arbitrary stack or duct without experimental data to meet the ANSI/HPS N13.1-1999 requirements. The goal of this study was to develop experimental data for a range of conditions in "S" (S-shaped configuration) duct systems with different mixing elements and "S" systems having one or two mixing elements. Results were presented in terms of the coefficients of variation (COVs) for velocity, tracer gas, and 10-mum aerodynamic diameter (AD) aerosol particle profiles at different downstream locations for each mixing element. Five mixing elements were tested, including a 90 degrees elbow, a commercial static mixer, a Small-Horizontal Generic-Tee-Plenum (SH-GTP), a Small-Vertical Generic-Tee-Plenum (SV-GTP), and a Large-Horizontal Generic-Tee-Plenum (LH-GTP) system. The COVs for velocity, gas concentration, and aerosol particles for the three GTP systems were all determined to be less than 8%. Tests with two different sizes of GTPs were conducted, and the results showed the performance of the GTPs was relatively unaffected by either size or velocity as reflected by the Reynolds number. The pressure coefficients were 0.59, 0.57, and 0.65, respectively, for the SH-GTP, SV-GTP, and LH-GTP. The pressure drop for the GTPs was approximately twice that of the round elbow, but a factor of 5 less than a Type IV Air Blender. The GTP was developed to provide a sampling location less than 4-duct diameters downstream of a mixing element with low pressure drop condition. The object of the developmental effort was to provide a system that could be employed in new stack; however, the concept of GTPs could also be retrofitted onto existing system applications as well. Results from these tests show that the system performance is well within the ANSI

  6. Predictors of failure of the commonly used single-dose methotrexate protocol for treating tubal ectopic pregnancies

    Directory of Open Access Journals (Sweden)

    Eser Sefik Ozyurek

    2017-12-01

    Conclusion: Day (0–4 thresholds or newly defined day (4–7 thresholds were not more sensitive than the conventional day (4–7 criteria. Day (0–4 β-hCG levels increased by more than 9.7% in half the patients who required additional methotrexate doses or surgery despite fulfillment of the conventional day (4–7 criteria. In contrast, no cases of treatment failure were observed if the day (0–4 decrease was >26.6%.

  7. Root Cause Analysis and Correction of Single Metal Contact Open-Induced Scan Chain Failure in 90nm node VLSI

    OpenAIRE

    Ting, Chao-Cheng; Liu, Ya-Chi; Chen, Hsuan-Hsien; Tsai, Chung-Ching; Shih, Liwen

    2018-01-01

    In this paper, the localization of open metal contact for 90nm node SOC is reported based on Electron Beam Absorbed Current (EBAC) technique and scan diagnosis for the first time. According to the detected excess carbon, silicon and oxygen signals obtained from X-ray energy dispersive spectroscopy (EDX), the failure was deemed to be caused by the incomplete removal of silicate photoresist polymer formed during the O2 plasma dry clean before copper plating. Based on this, we proposed to replac...

  8. X Marks the Spot: Creating and Managing a Single Service Point to Improve Customer Service and Maximize Resources

    Science.gov (United States)

    Venner, Mary Ann; Keshmiripour, Seti

    2016-01-01

    This article will describe how merging service points in an academic library is an opportunity to improve customer service and utilize staffing resources more efficiently. Combining service points provides libraries with the ability to create a more positive library experience for patrons by minimizing the ping-pong effect for assistance. The…

  9. Contraceptive failure

    DEFF Research Database (Denmark)

    Rasch, Vibeke

    2002-01-01

    , and 2614 received antenatal care. The variables studied comprise age, partner relationship, number of births, occupational and economical situation, and contraceptive use.Contraceptive failure, defined as contraceptive use (condom, diaphragm, IUD, oral contraception, or another modern method...... to use of condom and oral contraception than women aged 25-34 years. In addition, contraceptive failure was found to be associated with being single, a student, and having given birth twice or more previously. Regarding pregnancy acceptance, being 25-34 years of age was positively associated, whereas...

  10. Dynamics of single photon transport in a one-dimensional waveguide two-point coupled with a Jaynes-Cummings system

    KAUST Repository

    Wang, Yuwen

    2016-09-22

    We study the dynamics of an ultrafast single photon pulse in a one-dimensional waveguide two-point coupled with a Jaynes-Cummings system. We find that for any single photon input the transmissivity depends periodically on the separation between the two coupling points. For a pulse containing many plane wave components it is almost impossible to suppress transmission, especially when the width of the pulse is less than 20 times the period. In contrast to plane wave input, the waveform of the pulse can be modified by controlling the coupling between the waveguide and Jaynes-Cummings system. Tailoring of the waveform is important for single photon manipulation in quantum informatics. © The Author(s) 2016.

  11. FoCuS-point: software for STED fluorescence correlation and time-gated single photon counting

    DEFF Research Database (Denmark)

    Waithe, Dominic; Clausen, Mathias P; Sezgin, Erdinc

    2016-01-01

    microscopy (STED-FCS). Specifically, the use of gated detection has shown great potential for enhancing STED-FCS, but has also created a demand for software which is efficient and also implements the latest algorithms. Prior to this study, no open software has been available which would allow practical time...... to be established quickly and efficiently. AVAILABILITY AND IMPLEMENTATION: FoCuS-point is written in python and is available through the github repository: https://github.com/dwaithe/FCS_point_correlator. Furthermore, compiled versions of the code are available as executables which can be run directly in Linux...

  12. Phase transitions and multicritical points in the mixed spin-32 and spin-2 Ising system with a single-ion anisotropy

    International Nuclear Information System (INIS)

    Bobak, A.; Dely, J.

    2007-01-01

    The effect of a single-ion anisotropy on the phase diagram of the mixed spin-32 and spin-2 Ising system is investigated by the use of a mean-field theory based on the Bogoliubov inequality for the free energy. Topologically different kinds of phase diagrams are achieved by changing values of the parameter in the model Hamiltonian. Besides second-order transitions, lines of first-order transitions terminating either at a tricritical point or an isolated critical point, are found

  13. SU-E-T-263: Point Dose Variation Using a Single Ir-192 HDR Brachytherapy Plan for Two Treatments with a Single Tandem-Ovoid Insertion for Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liang, X; Morrill, S; Hardee, M; Han, E; Penagaricano, J; Zhang, X; Vaneerat, R [University of Arkansas Medical Science, Little Rock, AR (United States)

    2014-06-01

    Purpose: To evaluate the point dose variations between Ir-192 HDR treatments on two consecutive days using a single tandem-ovoid insertion without replanning in cervical cancer patients. Methods: This study includes eleven cervical cancer patients undergoing HDR brachytherapy with a prescribed dose of 28 Gy in 4 fractions. Each patient had two tandemovoid insertions one week apart. Each insertion was treated on consecutive days with rescanning and replanning prior to each treatment. To study the effect of no replanning for day 2 treatments, the day 1 plan dwell position and dwell time with decay were applied to the day 2 CT dataset. The point dose variations on the prescription point H (defined according to American Brachytherapy Society), and normal tissue doses at point B, bladder, rectum and vaginal mucosa (based on ICRU Report 38) were obtained. Results: Without replanning, the mean point H dose variation was 4.6 ± 10.7% on the left; 2.3 ± 2.9% on the right. The mean B point variation was 3.8 ± 4.9% on the left; 3.6 ± 4.7% on the right. The variation in the left vaginal mucosal point was 12.2 ± 10.7%; 9.5 ± 12.5% on the right; the bladder point 5.5 ± 7.4%; and the rectal point 7.9 ± 9.1%. Conclusion: Without replanning, there are variations both in the prescription point and the normal tissue point doses. The latter can vary as much as 10% or more. This is likely due to the steep dose gradient from brachytherapy compounded by shifts in the positions of the applicator in relationship to the patients anatomy. Imaging prior to each treatment and replanning ensure effective and safe brachytherapy are recommended.

  14. Comparison of single point normalized and modified Gate's method for measurement of glomerular filtration rate by nuclear medicine

    International Nuclear Information System (INIS)

    Fonseca, L.M.B. da; Fonseca, N.M.; Martins, E.; Pereira, E.

    1992-01-01

    Glomerular filtration rate was measured in 22 patients (mean age 30 years) using a noninvasive modified Gates method and the results were compared to the one point normalized technique. The values obtained were 74-11.7 and 82-11.09 ml/min., respectively. The advantages of the method are its reliability, easy adaptation to small laboratories and the avoidance of blood and urine sampling. (author)

  15. Safety of multi-channel stimulation implants: a single blocking capacitor per channel is not sufficient after single-fault failure.

    Science.gov (United States)

    Nonclercq, Antoine; Lonys, Laurent; Vanhoestenberghe, Anne; Demosthenous, Andreas; Donaldson, Nick

    2012-04-01

    One reason given for placing capacitors in series with stimulation electrodes is that they prevent direct current flow and therefore tissue damage under fault conditions. We show that this is not true for multiplexed multi-channel stimulators with one capacitor per channel. A test bench of two stimulation channels, two stimulation tripoles and a saline bath was used to measure the direct current flowing through the electrodes under two different single fault conditions. The electrodes were passively discharged between stimulation pulses. For the particular condition used (16 mA, 1 ms stimulation pulse at 20 Hz with electrodes placed 5 cm apart), the current ranged from 38 to 326 μA depending on the type of fault. The variation of the fault current with time, stimulation amplitude, stimulation frequency and distance between the electrodes is given. Possible additional methods to improve safety are discussed.

  16. Bee venom acupuncture point injection for central post stroke pain: a preliminary single-blind randomized controlled trial.

    Science.gov (United States)

    Cho, Seung-Yeon; Park, Joo-Young; Jung, Woo-Sang; Moon, Sang-Kwan; Park, Jung-Mi; Ko, Chang-Nam; Park, Seong-Uk

    2013-06-01

    We investigated apipuncture, or acupuncture point injection with diluted bee venom, as a promising new treatment for central post stroke pain (CPSP). Bee venom, diluted to 0.005% in normal saline, was administered to the treatment group, and normal saline given to control group as twice-weekly injections for three weeks. The points were LI15, GB21, LI11, GB31, ST36 and GB39 of the affected side and the amount of injection was 0.05 ml at each point. Eight patients in each group were included in the analysis. After three weeks there were significant decreases in visual analogue pain scores compared with baseline in both groups and the treatment group improved more significantly than the control group (p = 0.009). Apipuncture significantly improved CPSP in this pilot trial. Further studies of its mechanisms and a larger and long-term follow-up trial will be needed to determine more definitely the efficacy of apipuncture and to elucidate duration of improvement. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Respiratory Failure in Children With Hemato-oncological Diseases Admitted to the PICU: A Single-center Experience.

    Science.gov (United States)

    García-Salido, Alberto; Mastro-Martínez, Ignacio; Cabeza-Martín, Beatriz; Oñoro, Gonzalo; Nieto-Moro, Montserrat; Iglesias-Bouzas, María I; Serrano-González, Ana; Casado-Flores, Juan

    2015-08-01

    Respiratory failure (RF) is a main cause of pediatric intensive care unit (PICU) admission in children with hemato-oncological diseases. We present a retrospective chart review of children admitted to our PICU because of RF (January 2006 to December 2010). The aims of this study are the following: (1) to describe the demographical and clinical characteristics and respiratory management of these children; and (2) to identify the factors associated with mechanical ventilation (MV) and mortality. A total of 69 patients, encompassing 88 episodes, were included (55/88 cases were hypoxemic RF). The first respiratory support at PICU admission was, in decreasing order of frequency, high-flow oxygen nasal cannula (HFNC; 50/88), noninvasive ventilation (NIV; 13/88), and oxygen nasal cannula (16/88). MV was necessary in 47/88 episodes, 38/47 after another respiratory support. In 18/28 children with initial NIV, MV was required later. MV was associated with O-PRISM score, NIV requirement, suspected respiratory infection, and days of PICU treatment. Patients without MV showed an increased survival rate (P=0.001). In summary, the hypoxemic RF was the main cause of PICU admission, and HFNC or NIV was almost always the first respiratory support. The use of MV was associated with a higher mortality rate. The utility of precocious HFNC or NIV should be investigated in larger clinical studies.

  18. Enhancing the accuracy of GPS point positioning by converting the single frequency data to dual frequency data

    Directory of Open Access Journals (Sweden)

    Aly M. El-naggar

    2011-09-01

    Full Text Available The global positioning system (GPS has been used to support a wide variety of applications, such as high-accuracy positioning and navigation. Differential GPS techniques can largely eliminate common-mode errors between the reference and the rover GPS stations resulting from ionospheric and tropospheric refraction and delays, satellite and receiver clock biases, and orbital errors [1]. The ionospheric delay in the propagation of global positioning system (GPS signals is one of the main sources of error in GPS precise positioning and navigation. A dual-frequency GPS receiver can eliminate (to the first order the ionospheric delay through a linear combination of the L1 and L2 observations [2]. The most significant effect of ionospheric delay appear in case of using single frequency data. In this paper the single frequency data of concerned station are converted to dual frequency data by employing dual frequency data from 11 regional GPS stations distributed around it. Total electron content (TEC was calculated at every GPS station to produce the mathematical model of TEC which is a function of latitude (Φ and longitude (λ. By using this mathematical model the values of TEC and L2 can be predicted at the single frequency GPS station for each satellite, after that the comparison between predicted and observation values of TEC and L2 was performed. The estimation method and test results of the proposed method indicates that the difference between predicted and observation values is very small.

  19. Fracture strength and failure mode of maxillary implant-supported provisional single crowns: a comparison of composite resin crowns fabricated directly over PEEK abutments and solid titanium abutments.

    Science.gov (United States)

    Santing, Hendrik Jacob; Meijer, Henny J A; Raghoebar, Gerry M; Özcan, Mutlu

    2012-12-01

    Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. The objectives of this study were to evaluate the fracture strength of implant-supported composite resin crowns on PEEK and solid titanium temporary abutments, and to analyze the failure types. Three types of provisional abutments, RN synOcta Temporary Meso Abutment (PEEK; Straumann), RN synOcta Titanium Post for Temporary Restorations (Straumann), and Temporary Abutment Engaging NobRplRP (Nobel Biocare) were used, and provisional screw-retained crowns using composite resin (Solidex) were fabricated for four different locations in the maxilla. The specimens were tested in a universal testing machine at a crosshead speed of 1 mm/minute until fracture occurred. The failure types were analyzed and further categorized as irreparable (Type 1) or reparable (Type 2). No significant difference was found between different abutment types. Only for the position of the maxillary central incisor, composite resin crowns on PEEK temporary abutments showed significantly lower (p Provisional crowns on PEEK abutments showed similar fracture strength as titanium temporary abutments except for central incisors. Maxillary right central incisor composite resin crowns on PEEK temporary abutments fractured below the mean anterior masticatory loading forces reported to be approximately 206 N. © 2010 Wiley Periodicals, Inc.

  20. A Phase I, Single Ascending Dose Study of Cimaglermin Alfa (Neuregulin 1β3 in Patients With Systolic Dysfunction and Heart Failure

    Directory of Open Access Journals (Sweden)

    Daniel J. Lenihan, MD

    2016-12-01

    Full Text Available A first-in-human, phase 1, double blind, placebo-controlled, single ascending dose study examined the safety, tolerability, and exploratory efficacy of intravenous infusion of a recombinant growth factor, cimaglermin alfa, in patients with heart failure and left ventricular systolic dysfunction (LVSD. In these patients on optimal guideline-directed medical therapy, cimaglermin treatment was generally tolerated except for transient nausea and headache and a dose-limiting toxicity was noted at the highest planned dose. There was a dose-dependent improvement in left ventricular ejection fraction lasting 90 days following infusion. Thus, cimaglermin is a potential therapy to enhance cardiac function in LVSD and warrants further investigation.

  1. First year's operation experience of the deepest SPM (Single Point Mooring) in the world

    Energy Technology Data Exchange (ETDEWEB)

    Millar, J.L.; Hughes, H.; Dyer, R.C.

    1979-01-01

    The British National Oil Corp. had a Single Anchor Leg Mooring (SALM) installed at the Thistle Field in Apr. 1977 for export loading of tankers pending completion of the Brent System 36 in. pipeline to Sullom-Voe, which became operational in Dec. 1978; the SALM will continue to be maintained in good condition as a standby alternative export outlet. Modification of the original three 80,000 dwt tankers during 1977 provided the original design capacity of an 80,000 dwt tanker, but with added clean ballast capacity to eliminate tank cleaning and treatment of dirty ballast water. A fully integrated tanker/SALM/platform instrumentation system monitors mooring loads, buoy and riser angles, and tanker status; the latter being radio telemetered to the nearby block platform. Operation of the system and necessary modifications are described.

  2. Extremely high genetic diversity in a single tumor points to prevalence of non-Darwinian cell evolution.

    Science.gov (United States)

    Ling, Shaoping; Hu, Zheng; Yang, Zuyu; Yang, Fang; Li, Yawei; Lin, Pei; Chen, Ke; Dong, Lili; Cao, Lihua; Tao, Yong; Hao, Lingtong; Chen, Qingjian; Gong, Qiang; Wu, Dafei; Li, Wenjie; Zhao, Wenming; Tian, Xiuyun; Hao, Chunyi; Hungate, Eric A; Catenacci, Daniel V T; Hudson, Richard R; Li, Wen-Hsiung; Lu, Xuemei; Wu, Chung-I

    2015-11-24

    The prevailing view that the evolution of cells in a tumor is driven by Darwinian selection has never been rigorously tested. Because selection greatly affects the level of intratumor genetic diversity, it is important to assess whether intratumor evolution follows the Darwinian or the non-Darwinian mode of evolution. To provide the statistical power, many regions in a single tumor need to be sampled and analyzed much more extensively than has been attempted in previous intratumor studies. Here, from a hepatocellular carcinoma (HCC) tumor, we evaluated multiregional samples from the tumor, using either whole-exome sequencing (WES) (n = 23 samples) or genotyping (n = 286) under both the infinite-site and infinite-allele models of population genetics. In addition to the many single-nucleotide variations (SNVs) present in all samples, there were 35 "polymorphic" SNVs among samples. High genetic diversity was evident as the 23 WES samples defined 20 unique cell clones. With all 286 samples genotyped, clonal diversity agreed well with the non-Darwinian model with no evidence of positive Darwinian selection. Under the non-Darwinian model, MALL (the number of coding region mutations in the entire tumor) was estimated to be greater than 100 million in this tumor. DNA sequences reveal local diversities in small patches of cells and validate the estimation. In contrast, the genetic diversity under a Darwinian model would generally be orders of magnitude smaller. Because the level of genetic diversity will have implications on therapeutic resistance, non-Darwinian evolution should be heeded in cancer treatments even for microscopic tumors.

  3. Performance evaluation of thermally treated graphite felt electrodes for vanadium redox flow battery and their four-point single cell characterization

    Science.gov (United States)

    Mazúr, P.; Mrlík, J.; Beneš, J.; Pocedič, J.; Vrána, J.; Dundálek, J.; Kosek, J.

    2018-03-01

    In our contribution we study the electrocatalytic effect of oxygen functionalization of thermally treated graphite felt on kinetics of electrode reactions of vanadium redox flow battery. Chemical and morphological changes of the felts are analysed by standard physico-chemical characterization techniques. A complex method four-point method is developed and employed for characterization of the felts in a laboratory single-cell. The method is based on electrochemical impedance spectroscopy and load curves measurements of positive and negative half-cells using platinum wire pseudo-reference electrodes. The distribution of ohmic and faradaic losses within a single-cell is evaluated for both symmetric and asymmetric electrode set-up with respect to the treatment conditions. Positive effect of oxygen functionalization is observed only for negative electrode, whereas kinetics of positive electrode reaction is almost unaffected by the treatment. This is in a contradiction to the results of typically employed cyclovoltammetric characterization which indicate that both electrodes are enhanced by the treatment to a similar extent. The developed four-point characterization method can be further used e.g., for the component screening and in-situ durability studies on single-cell scale redox flow batteries of various chemistries.

  4. A DAB Converter with Common-Point-Connected Winding Transformers Suitable for a Single-Phase 5-Level SST System

    Directory of Open Access Journals (Sweden)

    Hyeok-Jin Yun

    2018-04-01

    Full Text Available One of the main disadvantages of the multi-level solid-state transformer (SST system is the voltage imbalance on the output of the rectifier modules. This voltage imbalance can be caused by parameter mismatch of the active and passive components, different loads, and the floating structure of the high voltage DC-links. Some studies have been done to solve this voltage imbalance problem. A common way to avoid this imbalance is to balance the voltage of DC-links at the AC/DC conversion stage and balance the power between the modules at the DC/DC conversion stage. Most of these methods require a complex balancing controller or additional circuits. This paper proposes a novel dual active bridge (DAB converter specialized in power balancing in a single-phase 5-level SST system. The proposed DAB converter does not require any additional balancing controllers or techniques for power balancing. The performance of the proposed DAB converter was verified by simulation and experiments using a 3 kW 5-level SST prototype system.

  5. Safety and Palliative Efficacy of Single-Dose 8-Gy Reirradiation for Painful Local Failure in Patients With Stage IV Non-Small Cell Lung Cancer Previously Treated With Radical Chemoradiation Therapy

    Energy Technology Data Exchange (ETDEWEB)

    Topkan, Erkan, E-mail: docdretopkan@gmail.com [Baskent Department of Radiation Oncology, University Adana Medical Faculty, Adana (Turkey); Yildirim, Berna Akkus; Guler, Ozan Cem; Parlak, Cem [Baskent Department of Radiation Oncology, University Adana Medical Faculty, Adana (Turkey); Pehlivan, Berrin [Koc University, School of Medicine, Department of Radiation Oncology, Istanbul, and American Hospital, University of Texas MD Anderson Radiation Treatment Center, Istanbul (Turkey); Selek, Ugur [Medstar Hospital, Department of Radiation Oncology, Antalya (Turkey)

    2015-03-15

    Purpose: To investigate the safety and efficacy of single-dose 8-Gy palliative chest reirradiation (CRI) in metastatic non-small cell lung cancer (M-NSCLC) patients with painful thoracic failures (TF) within the previous radiation portal. Patients and Methods: We retrospectively analyzed the clinical data of 78 M-NSCLC patients who received single-dose 8-Gy CRI for painful TF after concurrent chemoradiation therapy to a total radiation dose of 52 to 66 Gy between 2007 and 2012. Primary endpoints included significant pain relief (SPR) defined as a ≥2 point decrement in the Visual Analogue Scale for Pain inventory (VAS-P), time to pain relief, and duration of pain control. Secondary objectives were survival and prognostic factors. Results: Treatment was well tolerated, with only 5.1% grade 3 pneumonitis and 1.3% grade 2 esophagitis. Pre-CRI median and post-CRI minimum VAS-P were 7 and 3 (P<.001), respectively. SPR was noted in 67 (85.9%) patients, and only 3 (3.9%) scored progressive pain. Median time to lowest VAS-P and duration of pain control were 27 days and 6.1 months, respectively. Median overall survival (OS) was 7.7 months, and the 1-year OS rate was 26.5%. On multivariate analyses, lower Eastern Cooperative Oncology group score (1-2; P<.001), absence of anemia (P=.001), and fewer metastatic sites (1-2; P<.001) were found to be associated with longer OS. Conclusions: Single-dose 8-Gy CRI provides safe, effective, and durable pain palliation for TF in radically irradiated M-NSCLC patients. Because of its convenience, lower cost, and higher comfort, the present protocol can be considered an appropriate option for patients with limited life spans.

  6. Nutritional analysis of gastric contents and body condition score at a single time point in feral horses in Australia.

    Science.gov (United States)

    Hampson, Brian A; Owens, Elizabeth; Watts, Kathryn A; Mills, Paul C; Pollitt, Christopher C; de Laat, Melody A

    2011-09-01

    To determine the impact of a free-choice diet on nutritional intake and body condition of feral horses. Cadavers of 41 feral horses from 5 Australian locations. Body condition score (BCS) was determined (scale of 1 to 9), and the stomach was removed from horses during postmortem examination. Stomach contents were analyzed for nutritional variables and macroelement and microelement concentrations. Data were compared among the locations and also compared with recommended daily intakes for horses. Mean BCS varied by location; all horses were judged to be moderately thin. The BCS for males was 1 to 3 points higher than that of females. Amount of protein in the stomach contents varied from 4.3% to 14.9% and was significantly associated with BCS. Amounts of water-soluble carbohydrate and ethanol-soluble carbohydrate in stomach contents of feral horses from all 5 locations were higher than those expected for horses eating high-quality forage. Some macroelement and microelement concentrations were grossly excessive, whereas others were grossly deficient. There was no evidence of ill health among the horses. Results suggested that the diet for several populations of feral horses in Australia appeared less than optimal. However, neither low BCS nor trace mineral deficiency appeared to affect survival of the horses. Additional studies on food sources in these regions, including analysis of water-soluble carbohydrate, ethanol-soluble carbohydrate, and mineral concentrations, are warranted to determine the provenance of such rich sources of nutrients. Determination of the optimal diet for horses may need revision.

  7. A single point mutation within the coding sequence of cholera toxin B subunit will increase its expression yield.

    Science.gov (United States)

    Bakhshi, Bita; Boustanshenas, Mina; Ghorbani, Masoud

    2014-07-01

    Cholera toxin B subunit (CTB) has been extensively considered as an immunogenic and adjuvant protein, but its yield of expression is not satisfactory in many studies. The aim of this study was to compare the expression of native and mutant recombinant CTB (rCTB) in pQE vector. ctxB fragment from Vibrio cholerae O1 ATCC14035 containing the substitution of mutant ctxB for amino acid S128T was amplified by PCR and cloned in pGETM-T easy vector. It was then transformed to E. coli Top 10F' and cultured on LB agar plate containing ampicillin. Sequence analysis confirmed the mature ctxB gene sequence and the mutant one in both constructs which were further subcloned to pQE-30 vector. Both constructs were subsequently transformed to E. coli M15 (pREP4) for expression of mature and mutant rCTB. SDS-PAGE analysis showed the maximum expression of rCTB in both systems at 5 hours after induction and Western-blot analysis confirmed the presence of rCTB in blotting membranes. The expression of mutant rCTB was much higher than mature rCTB, which may be the result of serine-to-threonine substitution at position 128 of mature rCTB amino acid sequence created by PCR mutagenesis. The mutant rCTB retained pentameric stability and its ability to bind to anti- cholera toxin IgG antibodies. Point mutation in ctxB sequence resulted in over-expression of rCTB, probably due to the increase of solubility of produced rCTB. Consequently, this expression system can be used to produce rCTB in high yield.

  8. On the Failure of Upscaling the Single-Collector Efficiency to the Transport of Colloids in an Array of Collectors

    Science.gov (United States)

    Messina, F.; Tosco, T.; Sethi, R.

    2017-12-01

    Colloidal transport and deposition in saturated porous media are phenomena of considerable importance in a large number of natural processes and engineering applications, such as the contaminant and microorganism propagation in aquifer systems, the development of innovative groundwater remediation technologies, air and water filtration, and many others. Therefore, a thorough understanding of particle filtration is essential for predicting the transport and fate of colloids in the subsurface environment. The removal efficiency of a filter is a key aspect for colloid transport in porous media. Several efforts were devoted to derive accurate correlations for the single collector efficiency, one of the key concept in the filtration theory. However, up scaling this parameter to the entire porous medium is still a challenge. The common up-scaling approach assumes the deposition to be independent of the transport history, which means that the collector efficiency is considered uniform along the porous medium. However, previous works showed that this approach is inadequate under unfavorable deposition conditions. This study demonstrates that it is not adequate even in the simplest case of favorable deposition. Computational Fluid Dynamics simulations were run for a simplify porous media geometry, composed of a vertical array of 50 identical spherical collectors. A combination of Lagrangian and Eulerian simulations were performed to analyze the particle transport under a broad range of parameters (i.e., particle size, particle density, water velocity). The results show the limits of the existing models to interpret the experimental data. In fact, the outcome evidenced that when particle deposition is not controlled by Brownian diffusion, non-exponential concentration profiles are retrieved, in contrast with the assumption of uniform efficiency. Moreover, when the deposition mechanisms of sedimentation and interception dominate, the efficiency of the first sphere of the

  9. Progress and Failure of Repository Projects for Radioactive Waste - a Comparative Analysis of Turning Points, Deadlock and Ways to get out

    International Nuclear Information System (INIS)

    Barth, Regine; Kallenbach-Herbert, Beate

    2009-12-01

    The examples of factors that may support or obstruct a disposal process give an overview of results from empirical studies with regard to the selected issues in site selection and approval procedure and public participation. They reveal how experience from disposal projects in different countries and from other large infrastructure projects may contribute to the shaping of national disposal projects. As was to be expected project specific features limit the level of detail with which factors of success or failure can be described. On the other hand a relatively large number of factors on a generic level can be identified. They give a clear indication as to which issues are important for the successful implementation of a disposal project for high active waste. The project specific implementation of generic success factors on the national level requires an additional step of analysis. In that step a detailed adaption under consideration of the specific situation and circumstances of a project can be performed

  10. Single scan parameterization of space-variant point spread functions in image space via a printed array: the impact for two PET/CT scanners

    Energy Technology Data Exchange (ETDEWEB)

    Kotasidis, F A; Matthews, J C; Angelis, G I; Noonan, P J; Jackson, A [Imaging, Genomics and Proteomics, Wolfson Molecular Imaging Centre, MAHSC, University of Manchester, Manchester (United Kingdom); Price, P [Academic Department of Radiation Oncology, University of Manchester, Manchester (United Kingdom); Lionheart, W R [School of Mathematics, Alan Turing Building, University of Manchester, Manchester (United Kingdom); Reader, A J, E-mail: fotis.kotasidis@mmic.man.ac.uk [Brain Imaging Centre, Montreal Neurological Institute, McGill University, Montreal, QC (Canada)

    2011-05-21

    Incorporation of a resolution model during statistical image reconstruction often produces images of improved resolution and signal-to-noise ratio. A novel and practical methodology to rapidly and accurately determine the overall emission and detection blurring component of the system matrix using a printed point source array within a custom-made Perspex phantom is presented. The array was scanned at different positions and orientations within the field of view (FOV) to examine the feasibility of extrapolating the measured point source blurring to other locations in the FOV and the robustness of measurements from a single point source array scan. We measured the spatially-variant image-based blurring on two PET/CT scanners, the B-Hi-Rez and the TruePoint TrueV. These measured spatially-variant kernels and the spatially-invariant kernel at the FOV centre were then incorporated within an ordinary Poisson ordered subset expectation maximization (OP-OSEM) algorithm and compared to the manufacturer's implementation using projection space resolution modelling (RM). Comparisons were based on a point source array, the NEMA IEC image quality phantom, the Cologne resolution phantom and two clinical studies (carbon-11 labelled anti-sense oligonucleotide [{sup 11}C]-ASO and fluorine-18 labelled fluoro-l-thymidine [{sup 18}F]-FLT). Robust and accurate measurements of spatially-variant image blurring were successfully obtained from a single scan. Spatially-variant resolution modelling resulted in notable resolution improvements away from the centre of the FOV. Comparison between spatially-variant image-space methods and the projection-space approach (the first such report, using a range of studies) demonstrated very similar performance with our image-based implementation producing slightly better contrast recovery (CR) for the same level of image roughness (IR). These results demonstrate that image-based resolution modelling within reconstruction is a valid alternative to

  11. Pre-fabricated zirconium dioxide implant abutments for single-tooth replacement in the posterior region: success and failure after 3 years of function.

    Science.gov (United States)

    Nothdurft, Frank P; Nonhoff, Joerg; Pospiech, Peter R

    2014-07-01

    Zirconia implant abutments have gained a much broader clinical use over the past few years. The aim of the present study was to assess the clinical performance of a pre-fabricated zirconium dioxide implant abutment for single-tooth replacement in the posterior region. Forty implants of the XiVE(®) S plus screw type (DENTSPLY Friadent, Mannheim, Germany) were inserted in the posterior region of 24 patients and provided with zirconium dioxide abutments (FRIADENT(®) CERCON(®) Abutment, DENTSPLY Friadent). The following parameters were used to document the state of soft tissue: modified plaque index, modified sulcus bleeding index and pocket depth. Mesial and distal bone levels were determined on radiographs during the prosthetic treatment and at the 36-month recall. Thirty-seven implants could be followed up after 36 months in function. One patient wearing two abutments was lost to follow-up. One abutment exhibited a rotational misfit after 2 years in function. A further abutment showed the same failure at the 36-months recall appointment. In the remaining 36 implants the soft and hard tissue parameters were indicative of a low inflammatory status. Compared to the baseline situation, a partly significant bone apposition could be observed. Chipping of parts of the veneering ceramic was registered in 22% of the remaining implant restorations. The use of zirconia abutments in this study lead to mainly healthy peri-implant hard and soft tissue conditions but, considering the observed failures after 3 years in function, clinical long-term results should be awaited before recommending full zirconia implant abutments in a posterior indication.

  12. Adenocarcinoma of the esophagus and esophago-gastric junction: The effects of single and combined modalities on the survival and patterns of failure following treatment

    International Nuclear Information System (INIS)

    Whittington, R.; Coia, L.R.; Haller, D.G.; Rubenstein, J.H.; Rosato, E.F.

    1990-01-01

    One hundred sixty-five patients with localized adenocarcinomas of the esophagus or esophago-gastric (EG) junction were treated with surgery alone, radiation therapy alone, chemotherapy alone, surgery followed by post-operative radiation therapy, chemotherapy, or chemosensitized radiation therapy, and chemosensitized radiation therapy alone. Patients were retrospectively evaluated for survival, control of tumor within the mediastinum, post-operative swallowing function, patterns of failure, and treatment-related morbidity. Follow-up of survivors ranges from 9-88 months (median 23 months). Chemotherapy and radiation therapy as single modalities were associated with a recurrence rate of 100%. Combined modality therapy significantly reduced the risk of local recurrence in all patient groups. Chemosensitized radiation therapy alone reduced the local recurrence rate to 48%, and surgery followed by radiation therapy reduced the local failure rate to 24%. When chemotherapy or chemosensitization was added to surgery plus radiation, the risk was further reduced to 15%. The use of combined modality therapy was also found to extend the survival of patients without excessive toxicity. Median survival was shortest among the group treated with radiation alone (5 months) and intermediate among patients following chemosensitized radiation alone (10 months) or complete surgical resection alone (15 months). Patients treated with all three modalities had the longest median survival (21 months). Based on this experience, the optimum treatment of these patients appears to include aggressive attempts at surgical resection with chemosensitized radiation therapy. Excellent pallination can also be achieved in unresectable patients with chemosensitized radiation therapy with a smaller chance for long term survival

  13. In-vivo visualisation of the anatomical structures related to the acupuncture points Dai mai and Shen mai by MRI: A single-case pilot study

    International Nuclear Information System (INIS)

    Moncayo, Roy; Rudisch, Ansgar; Diemling, Markus; Kremser, Christian

    2007-01-01

    The concept of acupuncture point localisation in Traditional Chinese Medicine (TCM) is based on millenary practical experience. Modern imaging methods such as PET, MRI and SPECT have been used primary for the investigation of the mechanisms of action of acupuncture. In this pilot single-case study we have evaluated the technical possibilities for in-vivo imaging of the anatomical relations of acupuncture points using state of the art MRI. Preliminary experiments relating to the quality of acupuncture needles under the setting of MRI were done both with stainless steel and gold needles. In a second step, in-vivo imaging was carried out. A licensed acupuncture practitioner (RM) chose two points belonging to the so-called extraordinary vessels. In 2 sequential, separate procedures, he inserted himself gold acupuncture needles using a neutral technique (known as Ping Bu Ping Xie) into the Dai mai and Shen mai points, i.e. gall bladder 26 and bladder 62. Imaging was done on a Siemens Magnetom Avanto MR scanner using a head array and body coil. Mainly T1-weighted imaging sequences, as routinely used for patient exams, were used to obtain multi-slice images. In the preliminary experiments only acupuncture needles made of gold showed enough stability in order to be used for further imaging procedures. Using an onion and a banana as an object, further studies showed that the gold needles produced a void defect that corresponds to the tip of the inserted needle, while at the same time an artefactually increased diameter was observed. The in-vivo experiments showed that the Dai mai point was in relation to the abdominal internal oblique muscle. The Shen mai point artefact showed up close to the longus and brevis peroneal tendons at the fibular malleolus. Side effects related to heating or burning were not observed. Improved anatomical recognition was obtained using 3D-volume rendering techniques. Through an adequate choice of acupuncture material (gold needles) as well as of

  14. Extended daily veno-venous high-flux haemodialysis in patients with acute renal failure and multiple organ dysfunction syndrome using a single path batch dialysis system.

    Science.gov (United States)

    Lonnemann, G; Floege, J; Kliem, V; Brunkhorst, R; Koch, K M

    2000-08-01

    In the treatment of acute renal failure in patients with multiple organ dysfunction syndrome (MODS), continuous renal replacement therapies (CRRT) are increasingly used because of excellent volume control in the presence of improved cardiovascular stability. Patients with MODS, however, are frequently catabolic and have a high urea generation rate requiring either cost-intensive high-volume CRRT or additional intermittent haemodialysis to provide adequate clearance of small-molecular waste products. We tested the closed-loop batch haemodialysis system (called Genius((R))) for the treatment of acute renal failure in patients with MODS in the intensive care unit. Blood flow and countercurrent dialysate flow were reduced to 70 ml/min. Thus the 75 l dialysate tank of the Genius((R)) system lasts for 18 h of extended single-path high-flux haemodialysis (18 h-HFD) using polysulphous F60 S((R)) dialysers. Blood pressure, body temperature, and venous blood temperature in the extracorporeal circuit (no heating of the dialysate), ultrafiltration rate, serum urea levels, dialyser urea clearance, and total urea removal were monitored. In addition we tested the bacteriological quality of the spent dialysate at the end of 18-h treatments. Twenty patients with acute renal failure and MODS were investigated. Averaged dialyser urea clearance was 59.8 ml/min (equal to 3.6 l/h or 64.8 l/day). Total removal of urea was 14.1+/-6.5 g/day keeping serum levels of urea below 13 mmol/l. Mean arterial pressure remained stable during the 18-h treatments with a mean ultrafiltration rate of 120 ml/h. The temperature in the venous blood tubing dropped by 5+/-0.5 degrees C during the 18-h treatment (0.28 degrees C/h) in the presence of unchanged core temperature in the patients. There was no bacterial growth in 2.5 l of spent dialysate (dialysis using the Genius((R)) system combines the benefits of CRRT (good cardiovascular stability, sterile dialysate) with the advantages of intermittent

  15. Glutamate Excitotoxicity Is Involved in the Induction of Paralysis in Mice after Infection by a Human Coronavirus with a Single Point Mutation in Its Spike Protein▿

    Science.gov (United States)

    Brison, Elodie; Jacomy, Hélène; Desforges, Marc; Talbot, Pierre J.

    2011-01-01

    Human coronaviruses (HCoV) are recognized respiratory pathogens, and some strains, including HCoV-OC43, can infect human neuronal and glial cells of the central nervous system (CNS) and activate neuroinflammatory mechanisms. Moreover, HCoV-OC43 is neuroinvasive, neurotropic, and neurovirulent in susceptible mice, where it induces chronic encephalitis. Herein, we show that a single point mutation in the viral spike (S) glycoprotein (Y241H), acquired during viral persistence in human neural cells, led to a hind-limb paralytic disease in infected mice. Inhibition of glutamate excitotoxicity using a 2-amino-3-(5-methyl-3-oxo-1,2-oxazol-4-yl)propranoic acid (AMPA) receptor antagonist (GYKI-52466) improved clinical scores related to the paralysis and motor disabilities in S mutant virus-infected mice, as well as protected the CNS from neuronal dysfunctions, as illustrated by restoration of the phosphorylation state of neurofilaments. Expression of the glial glutamate transporter GLT-1, responsible for glutamate homeostasis, was downregulated following infection, and GYKI-52466 also significantly restored its steady-state expression level. Finally, GYKI-52466 treatment of S mutant virus-infected mice led to reduced microglial activation, which may lead to improvement in the regulation of CNS glutamate homeostasis. Taken together, our results strongly suggest an involvement of excitotoxicity in the paralysis-associated neuropathology induced by an HCoV-OC43 mutant which harbors a single point mutation in its spike protein that is acquired upon persistent virus infection. PMID:21957311

  16. A single point mutation in Tomato spotted wilt virus NSs protein is sufficient to overcome Tsw-gene-mediated resistance in pepper.

    Science.gov (United States)

    Almási, Asztéria; Nemes, Katalin; Csömör, Zsófia; Tóbiás, István; Palkovics, László; Salánki, Katalin

    2017-06-01

    The nonstructural protein (NSs) of Tomato spotted wilt virus (TSWV) was previously identified as an avirulence determinant for Tsw-based resistance on pepper. The NSs of wild-type (WT) and resistance-breaking (RB) TSWV strains isolated in Hungary had only two amino acid substitutions (104, 461). We have analysed the ability of the NSs and their point mutant variants to trigger Tsw-mediated hypersensitive responses and RNA silencing suppressor (RSS) activity in patch assays. We identified a single amino acid change at position 104 (T-A) that was responsible for the necrosis induction or loss, while a significant difference was not detected in the RSS activity of the two parental strains. We have successfully complemented the infection of the WT strain on resistant pepper cultivar with the infectious S RNA transcript of the RB strain and the WT-T104A point mutant. Our work provides direct evidence that a single amino acid change can induce an RB phenotype.

  17. Adding point of care ultrasound to assess volume status in heart failure patients in a nurse-led outpatient clinic. A randomised study.

    Science.gov (United States)

    Gundersen, Guri Holmen; Norekval, Tone M; Haug, Hilde Haugberg; Skjetne, Kyrre; Kleinau, Jens Olaf; Graven, Torbjorn; Dalen, Havard

    2016-01-01

    Medical history, physical examination and laboratory testing are not optimal for the assessment of volume status in heart failure (HF) patients. We aimed to study the clinical influence of focused ultrasound of the pleural cavities and inferior vena cava (IVC) performed by specialised nurses to assess volume status in HF patients at an outpatient clinic. HF outpatients were prospectively included and underwent laboratory testing, history recording and clinical examination by two nurses with and without an ultrasound examination of the pleural cavities and IVC using a pocket-size imaging device, in random order. Each nurse worked in a team with a cardiologist. The influence of the different diagnostic tests on diuretic dosing was assessed descriptively and in linear regression analyses. Sixty-two patients were included and 119 examinations were performed. Mean±SD age was 74±12 years, EF was 34±14%, and N-terminal pro-brain natriuretic peptide (NT-proBNP) value was 3761±3072 ng/L. Dosing of diuretics differed between the teams in 31 out of 119 consultations. Weight change and volume status assessed clinically with and without ultrasound predicted dose adjustment of diuretics at follow-up (p<0.05). Change of oedema, NT-proBNP, creatinine, and symptoms did not (p≥0.10). In adjusted analyses, only volume status based on ultrasound predicted dose adjustments of diuretics at first visit and follow-up (all ultrasound p≤0.01, all other p≥0.2). Ultrasound examinations of the pleural cavities and IVC by nurses may improve diagnostics and patient care in HF patients at an outpatient clinic, but more studies are needed to determine whether these examinations have an impact on clinical outcomes. NCT01794715. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  18. Alternative end points to evaluate a therapeutic strategy in advanced colorectal cancer: evaluation of progression-free survival, duration of disease control, and time to failure of strategy--an Aide et Recherche en Cancerologie Digestive Group Study.

    Science.gov (United States)

    Chibaudel, Benoist; Bonnetain, Franck; Shi, Qian; Buyse, Marc; Tournigand, Christophe; Sargent, Daniel J; Allegra, Carmen J; Goldberg, Richard M; de Gramont, Aimery

    2011-11-01

    Progression-free survival (PFS) is not an optimal end point to evaluate therapeutic strategies in advanced colorectal cancer (ACRC). Therefore, composite end points have been proposed to evaluate a chemotherapy strategy when sequential treatments are available: duration of disease control (DDC) and time to failure of strategy (TFS). The goal of this study was to evaluate these alternative end points and their potential surrogacy for overall survival (OS). We pooled individual patient data from three randomized trials evaluating chemotherapy strategy, which accrued 1,042 patients with previously untreated ACRC. In these trials, first-line treatment was either oxaliplatin- or irinotecan-based chemotherapy. Compared with TFS, DDC included neither time interval between progression and next sequence of treatment nor time to progression if the best result of the next sequence of treatment was progression. There was good correlation between DDC and OS (correlation of median: r, 0.62; correlation of hazard ratio [HR]: adjusted copula R(2), 0.72) and between TFS and OS (correlation of median: r, 0.59; correlation of HR: adjusted copula R(2), 0.67). There was no correlation between PFS and OS (correlation of median: r, 0.45; correlation of HR: adjusted copula R(2), 0.47). DDC and TFS roughly achieved the same results. Both are acceptable new end points to evaluate a therapeutic strategy in ACRC. Although TFS achieved a pragmatic evaluation of a multiline strategy, DDC captured the effect of a specific sequence in a therapeutic strategy.

  19. Failure-free survival following brachytherapy alone or external beam irradiation alone for T1-2 prostate tumors in 2222 patients: results from a single practice

    International Nuclear Information System (INIS)

    Brachman, David G.; Thomas, Theresa; Hilbe, Joseph; Beyer, David C.

    2000-01-01

    Purpose: To evaluate failure-free survival (FFS) for brachytherapy (BT) alone compared to external beam radiotherapy (EBRT) alone for Stage T1-2 Nx-No Mo patients over the same time period by a single community-based practice in the prostate-specific antigen (PSA) era. Materials and Methods: The database of Arizona Oncology Services (a multiphysician radiation oncology practice in the Phoenix metropolitan area) was reviewed for patients meeting the following criteria: (1) T1 or T2 Nx-No Mo prostate cancer; (2) no prior or concurrent therapy including hormones; (3) treatment period 12/88-12/95; and (4) treatment with either EBRT alone or BT alone ( 125 I or 103 Pd). This yielded 1527 EBRT and 695 BT patients; no patients meeting the above criteria were excluded from analysis. Median follow-up for EBRT patients was 41.3 months and, for BT patients, 51.3 months. Patients were not randomized to either therapy but rather received EBRT or BT based upon patient, treating, and/or referring physician preference. PSA failure was defined according to the ASTRO consensus guidelines. The median patient age was 74 years for both groups. Results: Failure-free survival at 5 years for EBRT and BT are 69% and 71%, respectively (p = 0.91). For T stage, no significant difference in FFS at 5 years is observed between EBRT and BT for either T1 (78% vs. 83%, p = 0.47) or T2 (67% vs. 67%, p = 0.89) tumors. Analysis by Gleason score shows superior outcomes for Gleason 8-10 lesions treated with EBRT vs. BT (5-year FFS 52% vs. 28%, p = 0.04); outcomes for lower grade lesions (Gleason 4-6) when analyzed by Gleason score alone do not significantly differ according to treatment received. Patients with initial PSA values of 10-20 ng/dL have an improved FFS with EBRT vs. BT at 5 years (70% vs. 53%, p = 0.001); outcomes for patients with initial PSA ranges of 0-4 ng/dL, of > 4-10 ng/dL, and > 20 ng/dL did not differ significantly by treatment received. FFS was also determined for presenting

  20. A study on density functional theory of the effect of pressure on the formation and migration enthalpies of intrinsic point defects in growing single crystal Si

    Science.gov (United States)

    Sueoka, Koji; Kamiyama, Eiji; Kariyazaki, Hiroaki

    2012-05-01

    In 1982, Voronkov presented a model describing point defect behavior during the growth of single crystal Si from a melt and derived an expression to predict if the crystal was vacancy- or self-interstitial-rich. Recently, Vanhellemont claimed that one should take into account the impact of compressive stress introduced by the thermal gradient at the melt/solid interface by considering the hydrostatic pressure dependence of the formation enthalpy of the intrinsic point defects. To evaluate the impact of thermal stress more correctly, the pressure dependence of both the formation enthalpy (Hf) and the migration enthalpy (Hm) of the intrinsic point defects should be taken into account. Furthermore, growing single crystal Si is not under hydrostatic pressure but almost free of external pressure (generally in Ar gas under reduced pressure). In the present paper, the dependence of Hf and Hm on the pressure P, or in other words, the pressure dependence of the formation energy (Ef) and the relaxation volume (vf), is quantified by density functional theory calculations. Although a large number of ab initio calculations of the properties of intrinsic point defects have been published during the last years, calculations for Si crystals under pressure are rather scarce. For vacancies V, the reported pressure dependences of HfV are inconsistent. In the present study, by using 216-atom supercells with a sufficient cut-off energy and mesh of k-points, the neutral I and V are found to have nearly constant formation energies EfI and EfV for pressures up to 1 GPa. For the relaxation volume, vfI is almost constant while vfV decreases linearly with increasing pressure P. In case of the hydrostatic pressure Ph, the calculated formation enthalpy HfI and migration enthalpy HmI at the [110] dumbbell site are given by HfI = 3.425 - 0.057 × Ph (eV) and HmI = 0.981 - 0.039 × Ph (eV), respectively, with Ph given in GPa. The calculated HfV and HmV dependencies on Ph given by HfV = 3.543 - 0

  1. An experimental investigation on dynamics and heat transfer associated with a single droplet impacting on a hot surface above the Leidenfrost point temperature

    Energy Technology Data Exchange (ETDEWEB)

    Park, J.; Kim, H. [Kyung Hee Univ., Gyeonggi-do (Korea, Republic of). Dept. of Nuclear Engineering

    2016-07-15

    During large loss-of-coolant accidents in nuclear reactors, water splatters as the quench front propagates at the quenching surface, and many droplets of different sizes and velocities are generated and carried with the steam in the cooling channel. Heat transfer due to droplets striking an overheated fuel rod above the Leidenfrost point temperature is important for predicting the peak cladding temperature. This study investigated the dynamics and heat transfer characteristics when a single droplet at room temperature collided with a surface at 425 C experimentally, using synchronized high-speed video and infrared cameras. Various physical parameters related to heat transfer model development were measured, including the residence time, spreading diameter, local heat flux distribution, effective heat transfer area, average vapor film thickness, and total heat transfer per collision. The measured data were compared with the values of the physical parameters predicted by existing mechanistic models.

  2. A Generic Simulation Approach for the Fast and Accurate Estimation of the Outage Probability of Single Hop and Multihop FSO Links Subject to Generalized Pointing Errors

    KAUST Repository

    Ben Issaid, Chaouki

    2017-07-28

    When assessing the performance of the free space optical (FSO) communication systems, the outage probability encountered is generally very small, and thereby the use of nave Monte Carlo simulations becomes prohibitively expensive. To estimate these rare event probabilities, we propose in this work an importance sampling approach which is based on the exponential twisting technique to offer fast and accurate results. In fact, we consider a variety of turbulence regimes, and we investigate the outage probability of FSO communication systems, under a generalized pointing error model based on the Beckmann distribution, for both single and multihop scenarios. Selected numerical simulations are presented to show the accuracy and the efficiency of our approach compared to naive Monte Carlo.

  3. Introduction of a point mutation into an HLA class I single-chain trimer induces enhancement of CTL priming and antitumor immunity

    Directory of Open Access Journals (Sweden)

    Masanori Matsui

    2014-01-01

    Full Text Available We previously discovered one particular HLA-A*02:01 mutant that enhanced peptide-specific cytotoxic T lymphocyte (CTL recognition in vitro compared to wild-type HLA-A*02:01. This mutant contains a single amino acid substitution from histidine to leucine at position 74 (H74L that is located in the peptide-binding groove. To investigate the effect of the H74L mutation on the in vivo CTL priming, we took advantage of the technology of the HLA class I single-chain trimer (SCT in which three components involving a peptide, β2 microglobulin and the HLA class I heavy chain are joined together via flexible linkers. We generated recombinant adenovirus expressing SCT comprised influenza A matrix protein (FMP-derived peptide, β2 microglobulin and the H74L heavy chain. HLA-A*02:01 transgenic mice were immunized with the adenovirus, and the induction of peptide-specific CTLs and antitumor immunity was investigated. It was clearly shown that the H74L mutation enabled the HLA-A*02:01 SCT molecule to dramatically enhance both in vivo priming of FMP-specific CTLs and protection against a lethal challenge of tumor cells expressing FMP. These data present the first evidence that a simple point mutation in the HLA class I heavy chain of SCT is beneficial for improving CTL-based immunotherapy and prophylaxis to control tumors.

  4. Comparison of a multi-breath-hold and a single breath-hold cine imaging approach for 4D guide-point modeling of the left ventricle

    International Nuclear Information System (INIS)

    Heilmaier, C.; Schlosser, T.; Nassenstein, K.; Bruder, O.

    2010-01-01

    Purpose: Guide-point modeling (GPM) enables reliable and time-efficient assessment of left ventricular (LV) volumes when using sequences that allow acquisition of short- and long-axis scans within a single breath-hold. Slice misalignment may influence GPM analysis of standard multi-breath-hold images due to image acquisition in different breath-holds. Thus, our study aimed to assess if such an approach allows for reliable volumetric calculations in the clinical routine. Materials and Methods: 52 patients were examined on a 1.5 T scanner with multi-breath-hold acquisitions on the standard short- and long-axis using an SSFP (TR 3 ms, TE 1.5 ms, FA 60 ) sequence and a TPAT accelerated SSFP (TR 4.6 msec, TE 1.1msec, FA 60 , acceleration factor 3) sequence that covered the LV in 3 short- and 2 long-axis slices within a single breath-hold. For both datasets GPM was used to assess LV volumes. In addition, LV parameters were calculated by applying the summation of slices (SoS) approach (standard of reference) with the short-axis views of the multi-breath-hold dataset. Results: The post-processing times were shorter with both GPM approaches (both, p 0.97). Conclusion: Cine short- and long-axis images that had been acquired in different breath-holds can be reliably evaluated by the GPM approach. (orig.)

  5. Visit of Peters Higgs at Point 2 ALICE Experiment - British theoretical physicist, He worked on proposals to unify the weak and the electromagnetic forces into a single electroweak theory, The Boson of Higgs.

    CERN Multimedia

    Mona Schweizer

    2008-01-01

    Visit of Peters Higgs at Point 2 ALICE Experiment - British theoretical physicist, He worked on proposals to unify the weak and the electromagnetic forces into a single electroweak theory, The Boson of Higgs.

  6. Estimation of failure parameters for finite element simulations based on a single state of stress and arbitrary stress-strain relation

    NARCIS (Netherlands)

    Voormeeren, L.O.; Tang, L.; Walters, C.L.; Vredeveldt, A.W.

    2014-01-01

    Crash analysis in the maritime and offshore industry typically relies on failure criteria that are based only on uniaxial states of stress. However, it is well known that the failure strain depends on the state of stress, and the state of stress in ship collisions is not necessarily uniaxial.

  7. Slope Failure Simulations with MPM

    NARCIS (Netherlands)

    Vardon, P.J.; Wang, B.; Hicks, M.A.

    2017-01-01

    The simulation of slope failures, including both failure initiation and development, has been modelled using the material point method. By utilising a constitutive model which encompasses, in a simplified manner, both pre- and post-failure behaviour, the majority of types of geotechnical slope

  8. Kidney Failure

    Science.gov (United States)

    ... enough red blood cells. This is called kidney failure. If your kidneys fail, you need treatment to ... providers, family, and friends, most people with kidney failure can lead full and active lives. NIH: National ...

  9. Respiratory Failure

    Science.gov (United States)

    Respiratory failure happens when not enough oxygen passes from your lungs into your blood. Your body's organs, such as ... need oxygen-rich blood to work well. Respiratory failure also can happen if your lungs can't ...

  10. Heart Failure

    DEFF Research Database (Denmark)

    Jorsal, Anders; Wiggers, Henrik; McMurray, John J V

    2018-01-01

    This article briefly discusses the epidemiology of heart failure and diabetes and summarizes the key findings from the recent cardiovascular outcome trials in patients with type 2 diabetes, with a focus on heart failure as an endpoint.......This article briefly discusses the epidemiology of heart failure and diabetes and summarizes the key findings from the recent cardiovascular outcome trials in patients with type 2 diabetes, with a focus on heart failure as an endpoint....

  11. Heart Failure

    Science.gov (United States)

    Heart failure is a condition in which the heart can't pump enough blood to meet the body's needs. Heart failure does not mean that your heart has stopped ... and shortness of breath Common causes of heart failure are coronary artery disease, high blood pressure and ...

  12. A single-center experience of hemofiltration treatment for acute aortic dissection (Stanford type A) complicated with postoperative acute renal failure.

    Science.gov (United States)

    Qi, Peng; Zhang, Xi-Quan; Pang, Xin-Yan; Cao, Guang-Qing; Fang, Chang-Cun; Wu, Shu-Ming

    2015-01-01

    To investigate the effect of continuous venovenous hemofiltration (CVVH) for aortic dissection patients with acute renal failure after surgery in retrospective manner. A total of thirty-seven aortic dissection patients with postoperative acute renal failure accepted CVVH therapy. The effect of CVVH was evaluated by analyzing clinical condition changes and laboratory examination results. After treatment of CVVH, renal function and clinical symptoms were significantly improved in thirty patients. Eight of the thirty patients got completely renal function recovery within two weeks after CVVH therapy; and twenty-two of the thirty patients got completely renal function recovery within four weeks after CVVH therapy. Nevertheless, seven patients got no benefit from CVVH therapy with poor prognosis. CVVH is an effective treatment to most aortic dissection patients with postoperative acute renal failure. The effect of CVVH was correlated with original renal function, early CVVH therapy, and continuous intensive care.

  13. Eligibility of sacubitril-valsartan in a real-world heart failure population: a community-based single-centre study.

    Science.gov (United States)

    Norberg, Helena; Bergdahl, Ellinor; Lindmark, Krister

    2018-04-01

    This study aims to investigate the eligibility of the Prospective Comparison of Angiotensin Receptor-Neprilysin Inhibitor (ARNI) with ACE inhibitor to Determine Impact on Global Mortality and Morbidity in Heart Failure (PARADIGM-HF) study to a real-world heart failure population. Medical records of all heart failure patients living within the catchment area of Umeå University Hospital were reviewed. This district consists of around 150 000 people. Out of 2029 patients with a diagnosis of heart failure, 1924 (95%) had at least one echocardiography performed, and 401 patients had an ejection fraction of ≤35% at their latest examination. The major PARADIGM-HF criteria were applied, and 95 patients fulfilled all enrolment criteria and thus were eligible for sacubitril-valsartan. This corresponds to 5% of the overall heart failure population and 24% of the population with ejection fraction ≤ 35%. The eligible patients were significantly older (73.2 ± 10.3 vs. 63.8 ± 11.5 years), had higher blood pressure (128 ± 17 vs. 122 ± 15 mmHg), had higher heart rate (77 ± 17 vs. 72 ± 12 b.p.m.), and had more atrial fibrillation (51.6% vs. 36.2%) than did the PARADIGM-HF population. Only 24% of our real-world heart failure and reduced ejection fraction population was eligible for sacubitril-valsartan, and the real-world heart failure and reduced ejection fraction patients were significantly older than the PARADIGM-HF population. The lack of data on a majority of the patients that we see in clinical practice is a real problem, and we are limited to extrapolation of results on a slightly different population. This is difficult to address, but perhaps registry-based randomized clinical trials will help to solve this issue. © 2018 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of the European Society of Cardiology.

  14. Relative effectiveness of kinetic analysis vs single point readings for classifying environmental samples based on community-level physiological profiles (CLPP)

    Science.gov (United States)

    Garland, J. L.; Mills, A. L.; Young, J. S.

    2001-01-01

    The relative effectiveness of average-well-color-development-normalized single-point absorbance readings (AWCD) vs the kinetic parameters mu(m), lambda, A, and integral (AREA) of the modified Gompertz equation fit to the color development curve resulting from reduction of a redox sensitive dye from microbial respiration of 95 separate sole carbon sources in microplate wells was compared for a dilution series of rhizosphere samples from hydroponically grown wheat and potato ranging in inoculum densities of 1 x 10(4)-4 x 10(6) cells ml-1. Patterns generated with each parameter were analyzed using principal component analysis (PCA) and discriminant function analysis (DFA) to test relative resolving power. Samples of equivalent cell density (undiluted samples) were correctly classified by rhizosphere type for all parameters based on DFA analysis of the first five PC scores. Analysis of undiluted and 1:4 diluted samples resulted in misclassification of at least two of the wheat samples for all parameters except the AWCD normalized (0.50 abs. units) data, and analysis of undiluted, 1:4, and 1:16 diluted samples resulted in misclassification for all parameter types. Ordination of samples along the first principal component (PC) was correlated to inoculum density in analyses performed on all of the kinetic parameters, but no such influence was seen for AWCD-derived results. The carbon sources responsible for classification differed among the variable types with the exception of AREA and A, which were strongly correlated. These results indicate that the use of kinetic parameters for pattern analysis in CLPP may provide some additional information, but only if the influence of inoculum density is carefully considered. c2001 Elsevier Science Ltd. All rights reserved.

  15. Recommendations for collaborative paediatric research including biobanking in Europe: a Single Hub and Access point for paediatric Rheumatology in Europe (SHARE) initiative.

    Science.gov (United States)

    Kuemmerle-Deschner, Jasmin B; Hansmann, Sandra; Wulffraat, Nico M; Vastert, Sebastiaan J; Hens, Kristien; Anton, Jordi; Avcin, Tadej; Martini, Alberto; Koné-Paut, Isabelle; Uziel, Yosef; Ravelli, Angelo; Wouters, Carine; Shaw, David; Özen, Seza; Eikelberg, Andreas; Prakken, Berent J; Ruperto, Nicolino; Horneff, Gerd; Constantin, Tamas; Beresford, Michael W; Sikken, Marijn; Foster, Helen E; Haug, Iris; Schuller, Sabrina; Jägle, Christine; Benseler, Susanne M

    2018-03-01

    Innovative research in childhood rheumatic diseases mandates international collaborations. However, researchers struggle with significant regulatory heterogeneity; an enabling European Union (EU)-wide framework is missing. The aims of the study were to systematically review the evidence for best practice and to establish recommendations for collaborative research. The Paediatric Rheumatology European Single Hub and Access point for paediatric Rheumatology in Europe (SHARE) project enabled a scoping review and expert discussion, which then informed the systematic literature review. Published evidence was synthesised; recommendations were drafted. An iterative review process and consultations with Ethics Committees and European experts for ethical and legal aspects of paediatric research refined the recommendations. SHARE experts and patient representatives vetted the proposed recommendations at a consensus meeting using Nominal Group Technique. Agreement of 80% was mandatory for inclusion. The systematic literature review returned 1319 records. A total of 223 full-text publications plus 22 international normative documents were reviewed; 85 publications and 16 normative documents were included. A total of 21 recommendations were established including general principles (1-3), ethics (4-7), paediatric principles (8 and 9), consent to paediatric research (10-14), paediatric databank and biobank (15 and 16), sharing of data and samples (17-19), and commercialisation and third parties (20 and 21). The refined recommendations resulted in an agreement of >80% for all recommendations. The SHARE initiative established the first recommendations for Paediatric Rheumatology collaborative research across borders in Europe. These provide strong support for an urgently needed European framework and evidence-based guidance for its implementation. Such changes will promote research in children with rheumatic diseases. © Article author(s) (or their employer(s) unless otherwise

  16. Single-point ACT2 gene mutation in the Arabidopsis root hair mutant der1-3 affects overall actin organization, root growth and plant development.

    Science.gov (United States)

    Vaškebová, L; Šamaj, J; Ovecka, M

    2017-12-27

    The actin cytoskeleton forms a dynamic network in plant cells. A single-point mutation in the DER1 (deformed root hairs1) locus located in the sequence of ACTIN2, a gene for major actin in vegetative tissues of Arabidopsis thaliana, leads to impaired root hair development (Ringli C, Baumberger N, Diet A, Frey B, Keller B. 2002. ACTIN2 is essential for bulge site selection and tip growth during root hair development of Arabidopsis. Plant Physiology129: 1464-1472). Only root hair phenotypes have been described so far in der1 mutants, but here we demonstrate obvious aberrations in the organization of the actin cytoskeleton and overall plant development. Organization of the actin cytoskeleton in epidermal cells of cotyledons, hypocotyls and roots was studied qualitatively and quantitatively by live-cell imaging of transgenic lines carrying the GFP-FABD2 fusion protein and in fixed cells after phalloidin labelling. Patterns of root growth were characterized by FM4-64 vital staining, light-sheet microscopy imaging and microtubule immunolabelling. Plant phenotyping included analyses of germination, root growth and plant biomass. Speed of germination, plant fresh weight and total leaf area were significantly reduced in the der1-3 mutant in comparison with the C24 wild-type. Actin filaments in root, hypocotyl and cotyledon epidermal cells of the der1-3 mutant were shorter, thinner and arranged in more random orientations, while actin bundles were shorter and had altered orientations. The wavy pattern of root growth in der1-3 mutant was connected with higher frequencies of shifted cell division planes (CDPs) in root cells, which was consistent with the shifted positioning of microtubule-based preprophase bands and phragmoplasts. The organization of cortical microtubules in the root cells of the der1-3 mutant, however, was not altered. Root growth rate of the der1-3 mutant is not reduced, but changes in the actin cytoskeleton organization can induce a wavy root growth pattern

  17. Feasibility of in vivo three-dimensional T2*mapping using dicarboxy-PROXYL and CW-EPR-based single-point imaging.

    Science.gov (United States)

    Kubota, Harue; Komarov, Denis A; Yasui, Hironobu; Matsumoto, Shingo; Inanami, Osamu; Kirilyuk, Igor A; Khramtsov, Valery V; Hirata, Hiroshi

    2017-06-01

    The aim of this study was to demonstrate the feasibility of in vivo three-dimensional (3D) relaxation time T 2 * mapping of a dicarboxy-PROXYL radical using continuous-wave electron paramagnetic resonance (CW-EPR) imaging. Isotopically substituted dicarboxy-PROXYL radicals, 3,4-dicarboxy-2,2,5,5-tetra( 2 H 3 )methylpyrrolidin-(3,4- 2 H 2 )-(1- 15 N)-1-oxyl ( 2 H, 15 N-DCP) and 3,4-dicarboxy-2,2,5,5-tetra( 2 H 3 )methylpyrrolidin-(3,4- 2 H 2 )-1-oxyl ( 2 H-DCP), were used in the study. A clonogenic cell survival assay was performed with the 2 H-DCP radical using squamous cell carcinoma (SCC VII) cells. The time course of EPR signal intensities of intravenously injected 2 H, 15 N-DCP and 2 H-DCP radicals were determined in tumor-bearing hind legs of mice (C3H/HeJ, male, n = 5). CW-EPR-based single-point imaging (SPI) was performed for 3D T 2 * mapping. 2 H-DCP radical did not exhibit cytotoxicity at concentrations below 10 mM. The in vivo half-life of 2 H, 15 N-DCP in tumor tissues was 24.7 ± 2.9 min (mean ± standard deviation [SD], n = 5). The in vivo time course of the EPR signal intensity of the 2 H, 15 N-DCP radical showed a plateau of 10.2 ± 1.2 min (mean ± SD) where the EPR signal intensity remained at more than 90% of the maximum intensity. During the plateau, in vivo 3D T 2 * maps with 2 H, 15 N-DCP were obtained from tumor-bearing hind legs, with a total acquisition time of 7.5 min. EPR signals of 2 H, 15 N-DCP persisted long enough after bolus intravenous injection to conduct in vivo 3D T 2 * mapping with CW-EPR-based SPI.

  18. Cardiac EASE (Ensuring Access and Speedy Evaluation) – the impact of a single-point-of-entry multidisciplinary outpatient cardiology consultation program on wait times in Canada

    Science.gov (United States)

    Bungard, Tammy J; Smigorowsky, Marcie J; Lalonde, Lucille D; Hogan, Terry; Doliszny, Katharine M; Gebreyesus, Ghirmay; Garg, Sipi; Archer, Stephen L

    2009-01-01

    BACKGROUND: Universal access to health care is valued in Canada but increasing wait times for services (eg, cardiology consultation) raise safety questions. Observations suggest that deficiencies in the process of care contribute to wait times. Consequently, an outpatient clinic was designed for Ensuring Access and Speedy Evaluation (Cardiac EASE) in a university group practice, providing cardiac consultative services for northern Alberta. Cardiac EASE has two components: a single-point-of-entry intake service (prospective testing using physician-approved algorithms and previsit triage) and a multidisciplinary clinic (staffed by cardiologists, nurse practitioners and doctoral-trained pharmacists). OBJECTIVES: It was hypothesized that Cardiac EASE would reduce the time to initial consultation and a definitive diagnosis, and also increase the referral capacity. METHODS: The primary and secondary outcomes were time from referral to initial consultation, and time to achieve a definitive diagnosis and management plan, respectively. A conventionally managed historical control group (three-month pre-EASE period in 2003) was compared with the EASE group (2004 to 2006). The conventional referral mechanism continued concurrently with EASE. RESULTS: A comparison between pre-EASE (n=311) and EASE (n=3096) revealed no difference in the mean (± SD) age (60±16 years), sex (55% and 52% men, respectively) or reason for referral, including chest pain (31% and 40%, respectively) and arrhythmia (27% and 29%, respectively). Cardiac EASE reduced the time to initial cardiac consultation (from 71±45 days to 33±19 days) and time to a definitive diagnosis (from 120±86 days to 51±58 days) (P<0.0001). The annual number of new referrals increased from 1512 in 2002 to 2574 in 2006 due to growth in the Cardiac EASE clinic. The number of patients seen through the conventional referral mechanism and their wait times remained constant during the study period. CONCLUSIONS: Cardiac EASE reduced

  19. Fatigue resistance and failure mode of novel-design anterior single-tooth implant restorations: influence of material selection for type III veneers bonded to zirconia abutments.

    Science.gov (United States)

    Magne, Pascal; Paranhos, Maria Paula Gandolfi; Burnett, Luiz Henrique; Magne, Michel; Belser, Urs Christoph

    2011-02-01

    This study assessed the fatigue resistance and failure mode of type III porcelain and composite resin veneers bonded to custom zirconia implant abutments. Twenty-four standardized zirconia implant abutments were fabricated. Using the CEREC 3 machine, type III veneers of standardized shape were milled in ceramic Vita Mark II or in composite resin Paradigm MZ100. The intaglio surfaces of the restorations were hydrofluoric acid etched and silanated (Mark II) or airborne-particle abraded and silanated (MZ100). The fitting surface of the abutments was airborne-particle abraded, cleaned, and inserted into a bone level implant (BLI RC SLActive 10 mm). All veneers (n=24) were adhesively luted with a zirconia primer (Z-Prime Plus), adhesive resin (Optibond FL) and a pre-heated light-curing composite resin (Filtek Z100). Cyclic isometric chewing (5 Hz) was simulated, starting with a load of 40 N, followed by stages of 80, 120, 160, 200, 240, and 280 N (20,000 cycles each). Samples were loaded until fracture or to a maximum of 140,000 cycles. Groups were compared using the life table survival analysis (Logrank test at P=.05). Mark II and MZ100 specimens fractured at an average load of 216 N and 229 N (survival rate of 17% and 8%), respectively, with no difference in survival probability (P=.18). Among the fractured samples, 40% of the failures were at the abutment level for Mark II and 27% were at the abutment level for MZ100. No exclusive adhesive failures were observed. Type III Mark II and Paradigm MZ100 veneers showed similar fatigue resistance when bonded to custom non-retentive zirconia implant abutments. The bond was strong enough to induce abutment fractures. MZ100 presented a higher percentage of "friendly" failures, i.e. maintaining the restoration-abutment adhesive interface and the abutment itself intact. © 2010 John Wiley & Sons A/S.

  20. Biochemical failure as single abnormality in patients with prostate cancer following radical treatment with external radiotherapy: follow-up without immediate treatment

    Directory of Open Access Journals (Sweden)

    Sergio L. Faria

    2004-08-01

    Full Text Available INTRODUCTION: Biochemical failure has been defined as 3 consecutive increases in PSA following curative treatment of prostate cancer. The appropriate management in such cases is controversial. The most usual treatment has been early introduction of hormones. Such patients will live for many years and hormone therapy causes important secondary effects and increases costs. The guideline in our Department of Radiotherapy has been to follow up, with no initial therapy, cases with low PSA and short PSA doubling time. The present study reports this experience. MATERIALS AND METHODS: 528 patients with localized prostate cancer were treated by radical approach between 1992 and 1999, with external radiotherapy, with or without adjuvant hormone therapy. After a median follow-up of 77 months, there were 207 (39% cases with biochemical failure, 78 of which were followed without therapy after the identification of biochemical failure. All of them were asymptomatic patients and had negative radiographic examinations or did not have imaging exams requested since they presented a favorable outcome. The follow-up included at least 2 annual visits with physical examination and PSA. RESULTS: Of the 78 patients with biochemical failure followed without initial therapy, 7 died from other causes than prostate cancer and the remaining 71 cases were alive and asymptomatic in the last follow-up. Prognostic factors previous to radiotherapy such as stage and Gleason score were not considered when deciding for follow-up without initial therapy in these cases. The most significant aspects considered for this decision were low PSA value (median PSA on the last visit for the 78 cases was only 3.9 ng/mL and a slow PSA doubling time (in the present experience the median PSA doubling time was 22.5 months. CONCLUSION: There seems to be space for expectant management, without initial hormone therapy, in patients with prostate cancer who present biochemical failure and are

  1. Comparison of in-vivo failure of single-thread and dual-thread temporary anchorage devices over 18 months: A split-mouth randomized controlled trial.

    Science.gov (United States)

    Durrani, Owais Khalid; Shaheed, Sohrab; Khan, Arsalan; Bashir, Ulfat

    2017-10-01

    The purpose of this study was to compare the in-vivo failure rates of single-thread and dual-thread temporary anchorage device (TAD) designs over 18 months. Thirty patients with skeletal Class II Division 1 malocclusion requiring anchorage from TADs for retraction of maxillary incisors into the extracted premolar space were recruited in this parallel group, split-mouth, randomized controlled trial. A block randomization sequence was generated with Random Allocation Software (version 2.0; Isfahan, Iran) with the allocations concealed in sequentially numbered, opaque, sealed envelopes. A total of 60 TADs (diameter, 2 mm; length, 10 mm) were placed in the maxillary arches of these patients with random allocation of the 2 types to the left and the right sides in a 1:1 ratio. All TADs were placed between the roots of the second premolar and the first molar and were immediately loaded. Patients were followed for a minimum of 12 months and a maximum of 18 months for the failure of the TADs. Data were analyzed blindly on an intention-to-treat basis. Four TADs (13.3%) failed in the single-thread group, and 6 TADs (20%) failed in the dual-thread group. The McNemar test showed an insignificant difference (P = 0.72) between the 2 groups. An odds ratio of 1.6 (95% confidence interval, 0.39-6.97) showed no significant associations among the variables. Most TADs failed in the first month after insertion (50%). The failure rate of dual-thread TADs compared with single-thread TADs is statistically insignificant when placed in the maxilla for retraction of the anterior segment. Registration: The trial was not registered before commencement. The protocol was not published before the trial. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  2. Fracture Strength and Failure Mode of Maxillary Implant-Supported Provisional Single Crowns : A Comparison of Composite Resin Crowns Fabricated Directly Over PEEK Abutments and Solid Titanium Abutments

    NARCIS (Netherlands)

    Santing, H.J.; Meijer, Henny J.A.; Raghoebar, G.M.; Ozcan, M.

    2012-01-01

    Background: Polyetheretherketone (PEEK) temporary abutments have been recently introduced for making implant-supported provisional single crowns. Little information is available in the dental literature on the durability of provisional implant-supported restorations. Purpose: The objectives of this

  3. Slope failure simulations with MPM

    NARCIS (Netherlands)

    Vardon, P.J.; Wang, B.; Hicks, M.A.

    2017-01-01

    The simulation of slope failures, including both failure initiation and development, has been modelled using the material point method (MPM). Numerical case studies involving various slope angles, heterogeneity and rainfall infiltration are presented. It is demonstrated that, by utilising a

  4. Testicular failure

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/000395.htm Testicular failure To use the sharing features on this page, ... Professor of Medicine, Division of Metabolism, Endocrinology & Nutrition, University of Washington School of Medicine, Seattle, WA. Also ...

  5. Eradication of large solid tumors by gene therapy with a T cell receptor targeting a single cancer-specific point mutation

    Science.gov (United States)

    Leisegang, Matthias; Engels, Boris; Schreiber, Karin; Yew, Poh Yin; Kiyotani, Kazuma; Idel, Christian; Arina, Ainhoa; Duraiswamy, Jaikumar; Weichselbaum, Ralph R.; Uckert, Wolfgang; Nakamura, Yusuke; Schreiber, Hans

    2015-01-01

    Purpose Cancers usually contain multiple unique tumor-specific antigens produced by single amino acid substitutions (AAS) and encoded by somatic non-synonymous single nucleotide substitutions. We determined whether adoptively transferred T cells can reject large, well-established solid tumors when engineered to express a single type of T cell receptor (TCR) that is specific for a single AAS. Experimental Design By exome and RNA sequencing of an UV-induced tumor, we identified an AAS in p68 (mp68), a co-activator of p53. This AAS seemed to be an ideal tumor-specific neoepitope because it is encoded by a trunk mutation in the primary autochthonous cancer and binds with highest affinity to the MHC. A high-avidity mp68-specific TCR was used to genetically engineer T cells as well as to generate TCR-transgenic mice for adoptive therapy. Results When the neoepitope was expressed at high levels and by all cancer cells, their direct recognition sufficed to destroy intra-tumor vessels and eradicate large, long-established solid tumors. When the neoepitope was targeted as autochthonous antigen, T cells caused cancer regression followed by escape of antigen-negative variants. Escape could be thwarted by expressing the antigen at increased levels in all cancer cells or by combining T cell therapy with local irradiation. Therapeutic efficacies of TCR-transduced and TCR-transgenic T cells were similar. Conclusions Gene therapy with a single TCR targeting a single AAS can eradicate large established cancer but a uniform expression and/or sufficient levels of the targeted neoepitope or additional therapy are required to overcome tumor escape. PMID:26667491

  6. Single-phase AutoReClosure ARC failure on 400 kV combinedcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    consisting of overhead lines, crossbonded cable sections and shunt reactor has been created in PSCAD/EMTDC and verified against measurements with good results. Main focus has been put on the likelihood of having a successful single-phase autoreclosure ARC in such a combined cable/OHL line....

  7. What controls the failure process of irregularly-shaped reinforced ...

    African Journals Online (AJOL)

    The failure process starts with the cracking of the tensile concrete at the critical cross-section. It is found that the maximum load point is the peak of the failure process while the maximum bending moment occurs later. The first point represents the stability failure, while the second corresponds to the material failure of the ...

  8. Adjacent, distal, or combination of point-selective effects of acupuncture on temporomandibular joint disorders: A randomized, single-blind, assessor-blind controlled trial

    Directory of Open Access Journals (Sweden)

    Kyung-Won Kang

    2012-12-01

    Conclusion: Our results suggest that point-selective effects among adjacent, distal, or a combination of acupoints are hardly associated with pain intensity or palpation index in participants with TMDs. Larger sample size trials are required to overcome the shortcomings of the study.

  9. Intention-to-Treat Analysis of Radical Trachelectomy for Early-Stage Cervical Cancer With Special Reference to Oncologic Failures: Single-Institutional Experience in Hungary.

    Science.gov (United States)

    Póka, Robert; Molnár, Szabolcs; Daragó, Péter; Lukács, János; Lampé, Rudolf; Krasznai, Zoárd; Hernádi, Zoltán

    2017-09-01

    The aim of our study was to evaluate clinical and pathological data in order to draw eligibility criteria for oncologically sufficient radical trachelectomy (RT) in early-stage cervical cancer. Reviewing all cases of attempted RT performed at our unit, we focused attention on prognostic indicators of the need for additional oncologic treatment following RT. The analysis was extended by extensive literature review to include previously published cases of oncologic failures. The authors retrospectively analyzed data of patients who underwent RT at the Department of Obstetrics and Gynecology, University of Debrecen. Electronic records and case notes of RT cases were reviewed to determine the incidence of abdominal and vaginal route, distribution of clinicopathologic data, and follow-up results of individual cases. Individual procedures were categorized as oncologically insufficient if additional oncologic treatment was necessary following RT. Theoretical eligibility criteria for RT in early-stage cervical cancer were determined retrospectively by selecting prognostic features that were associated with oncologic insufficiency from clinicopathologic indicators of the complete series. Twenty-four cases of RT were performed by the authors, 15 vaginal RTs with laparoscopic pelvic lymphadenectomy and 9 abdominal RTs with open pelvic lymphadenectomy. Fifteen of 24 cases proved oncologically sufficient. Three cases required immediate conversion to radical hysterectomy because of positive sentinel nodes and/or positive isthmic disc on frozen section. In further 5 cases, final pathology results indicated additional oncologic treatment, that is, radical hysterectomy (n = 2), chemoradiotherapy (n = 2), or chemotherapy (n = 1). One patient among immediately converted cases and another 3 among those who required additional oncologic treatment died of their disease later. There were no other cases of recurrences over a median follow-up of 34 months (range, 12-188 months). Factors

  10. A NOVEL SINGLE IMPEDANCE NETWORK BASED NEUTRAL POINT CLAMPED SEVEN LEVEL THREE PHASE INVETER WITH REDUCED CLAMPING DIODES FOR REGENERATIVE APPLICATIONS

    OpenAIRE

    T. A. Raghavendiran; C.L.Kuppuswamy

    2012-01-01

    A Multilevel Inverter (MLI) can eliminate the need for the step-up transformer and reduce the harmonics produced by the inverter. This paper presents Neutral Point Clamped (NPC) seven level inverter with less number of clamping diodes which is suitable for regenerative loads such as three phase induction motor with regenerative braking. To reduce the stress across the main switches, diodes are clamped anti-parallel to the main switches. In Earlier configurations, the numbers of clamping diode...

  11. Ab initio analysis of a vacancy and a self-interstitial near single crystal silicon surfaces: Implications for intrinsic point defect incorporation during crystal growth from a melt

    Energy Technology Data Exchange (ETDEWEB)

    Kamiyama, Eiji; Sueoka, Koji [Department of Communication Engineering, Okayama Prefectural University, 111 Kuboki, Soja, Okayama 719-1197 (Japan); Vanhellemont, Jan [Department of Solid State Sciences, Ghent University, Krijgslaan 281-S1, Gent 9000 (Belgium)

    2012-10-15

    The microscopic model of the Si (001) crystal surface was investigated by first principles calculations to clarify the behavior of intrinsic point defects near crystal surfaces. A c(4 x 2) structure model was used to describe the crystal surface in contact with vacuum. The calculations show lower formation energy near the surface and the existence of formation energy differences between the surface and the bulk for both types of intrinsic point defects. The tetrahedral (T)-site and the dumbbell (DB)-site, in which a Si atom is captured from the surface and forms a self-interstitial, are found as stable sites near the third atomic layer. The T-site has a barrier of 0.48 eV, whereas the DB-site has no barrier for the interstitial to penetrate into the crystal from the vacuum. Si atoms in a melt can migrate and reach at the third layer during crystal growth when bulk diffusion coefficient is used. Therefore, the melt/solid interface is always a source of intrinsic point defects. (Copyright copyright 2012 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  12. The analysis of dyes in ball point pen inks on single paper fibres using laser desorption ionisation time of flight mass spectrometry (LDI-TOFMS).

    Science.gov (United States)

    Matthews, Broderick; Walker, G Stewart; Kobus, Hilton; Pigou, Paul; Bird, Carolyne; Smith, Glyn

    2011-06-15

    An important requisite for the forensic analysis of inks on documents is that damage to the document is avoided or minimised. This paper describes a technique for dye identification in ballpoint pen inks using LDI-TOFMS on single ink bearing paper fibres and its application to a case. A single ink bearing paper fibre can be prised from the surface of the document under a stereo microscope and presented to the instrument for analysis without further treatment. This sampling process causes imperceptible damage to the surface of the document. Clear mass spectrometric identification of the ink dyes is obtained. A case example is provided to illustrate the practical application of the technique. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. An SVM-Based Classifier for Estimating the State of Various Rotating Components in Agro-Industrial Machinery with a Vibration Signal Acquired from a Single Point on the Machine Chassis

    Directory of Open Access Journals (Sweden)

    Ruben Ruiz-Gonzalez

    2014-11-01

    Full Text Available The goal of this article is to assess the feasibility of estimating the state of various rotating components in agro-industrial machinery by employing just one vibration signal acquired from a single point on the machine chassis. To do so, a Support Vector Machine (SVM-based system is employed. Experimental tests evaluated this system by acquiring vibration data from a single point of an agricultural harvester, while varying several of its working conditions. The whole process included two major steps. Initially, the vibration data were preprocessed through twelve feature extraction algorithms, after which the Exhaustive Search method selected the most suitable features. Secondly, the SVM-based system accuracy was evaluated by using Leave-One-Out cross-validation, with the selected features as the input data. The results of this study provide evidence that (i accurate estimation of the status of various rotating components in agro-industrial machinery is possible by processing the vibration signal acquired from a single point on the machine structure; (ii the vibration signal can be acquired with a uniaxial accelerometer, the orientation of which does not significantly affect the classification accuracy; and, (iii when using an SVM classifier, an 85% mean cross-validation accuracy can be reached, which only requires a maximum of seven features as its input, and no significant improvements are noted between the use of either nonlinear or linear kernels.

  14. Tipping Point

    Medline Plus

    Full Text Available ... en español Blog About OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point The Tipping Point by ... danger death electrical fall furniture head injury product safety television tipover tv Watch the video in Adobe ...

  15. Annular suspension and pointing system with controlled DC electromagnets

    Science.gov (United States)

    Vu, Josephine Lynn; Tam, Kwok Hung

    1993-01-01

    The Annular Suspension and Pointing System (ASPS) developed by the Flight System division of Sperry Corporation is a six-degree of freedom payload pointing system designed for use with the space shuttle. This magnetic suspension and pointing system provides precise controlled pointing in six-degrees of freedom, isolation of payload-carrier disturbances, and end mount controlled pointing. Those are great advantages over the traditional mechanical joints for space applications. In this design, we first analyzed the assumed model of the single degree ASPS bearing actuator and obtained the plant dynamics equations. By linearizing the plant dynamics equations, we designed the cascade and feedback compensators such that a stable and satisfied result was obtained. The specified feedback compensator was computer simulated with the nonlinearized plant dynamics equations. The results indicated that an unstable output occurred. In other words, the designed feedback compensator failed. The failure of the design is due to the Taylor's series expansion not converging.

  16. The effect of correlated and point defects on the vortex lattice melting transition in single crystal YBa2Cu3O7-δ

    International Nuclear Information System (INIS)

    Kwok, W.K.; Fleshler, S.; Welp, U.; Downey, J.; Crabtree, G.W.; Fendrich, J. Giapintzakis, J.

    1993-08-01

    The vortex melting transition T m in several untwinned and twinned crystals measured resistively in fields up to 8 Tesla. A Lindemann criterion for vortex lattice melting is obtained in addition to a sharp hysteresis in the magnetoresistance at B m supporting a first order phase transition. The anisotropy of twin boundary pinning and its reduction of the ''kink'' in ρ(T) associated with the first order melting transition is discussed in samples with very dilute twin boundaries. We also report on direct suppression of melting transition by intrinsic pinning for H parallel ab and by electron-irradiation-induced point defects

  17. High prevalence of malnutrition and inflammation in undialyzed patients with chronic renal failure in developing countries: a single center experience from eastern India.

    Science.gov (United States)

    Prakash, Jai; Raja, R; Mishra, R N; Vohra, Rubina; Sharma, Naveen; Wani, I A; Parekh, A

    2007-01-01

    Malnutrition is common in patients with chronic renal failure (CRF), and its prevalence before the initiation of dialysis is poorly characterized in these patients in developing countries. There is a paucity of data on the quantification of malnutrition and inflammation in undialyzed patients of CRF from India. This study analyzed the prevalence and causes of malnutrition in patients with CRF before the initiation of dialysis treatment. In the present study, assessments of nutritional and inflammatory status were carried out in patients with CRF. Serum albumin, body mass index (BMI), triceps skin fold thickness (TST), mid-arm muscle circumference (MAMC), and subjective global assessment (SGA) scoring were used for assessment of nutritional parameters. Serum C-reactive protein and serum ferritin level were used to assess the inflammatory state of the patient. Two hundred and three (146 male, 57 female) patients with CRF were included in the study from August 2004 to April 2006. Overall, the prevalence of malnutrition was 65% (131/203). The age of malnourished patients (93 male, 38 female) ranged from 11-82, with mean age of 52 +/- 12.68 years. The mean serum total protein and albumin were also significantly lower in patients with malnutrition in comparison to non malnourished cases (5.50 +/- 0.40 gm/dL vs. 5.74 +/- 0.38 gm/dL; p malnutrition was common in patients with CRF before the commencement of dialysis. These data indicate that an emphasis should be placed on the assessment and prevention or correction of malnutrition in patients with CRF because of its documented adverse effect on the outcome on maintenance dialysis.

  18. Cost-effectiveness of lumbar discectomy and single-level fusion for spondylolisthesis: experience with the NeuroPoint-SD registry.

    Science.gov (United States)

    Mummaneni, Praveen V; Whitmore, Robert G; Curran, Jill N; Ziewacz, John E; Wadhwa, Rishi; Shaffrey, Christopher I; Asher, Anthony L; Heary, Robert F; Cheng, Joseph S; Hurlbert, R John; Douglas, Andrea F; Smith, Justin S; Malhotra, Neil R; Dante, Stephen J; Magge, Subu N; Kaiser, Michael G; Abbed, Khalid M; Resnick, Daniel K; Ghogawala, Zoher

    2014-06-01

    There is significant practice variation and uncertainty as to the value of surgical treatments for lumbar spine disorders. The authors' aim was to establish a multicenter registry to assess the efficacy and costs of common lumbar spinal procedures by using prospectively collected outcomes. An observational prospective cohort study was completed at 13 academic and community sites. Patients undergoing single-level fusion for spondylolisthesis or single-level lumbar discectomy were included. The 36-Item Short Form Health Survey (SF-36) and Oswestry Disability Index (ODI) data were obtained preoperatively and at 1, 3, 6, and 12 months postoperatively. Power analysis estimated a sample size of 160 patients: lumbar disc (125 patients) and lumbar listhesis (35 patients). The quality-adjusted life year (QALY) data were calculated using 6-dimension utility index scores. Direct costs and complication costs were estimated using Medicare reimbursement values from 2011, and indirect costs were estimated using the human capital approach with the 2011 US national wage index. Total costs equaled $14,980 for lumbar discectomy and $43,852 for surgery for lumbar spondylolisthesis. There were 198 patients enrolled over 1 year. The mean age was 46 years (49% female) for lumbar discectomy (n = 148) and 58.1 years (60% female) for lumbar spondylolisthesis (n = 50). Ten patients with disc herniation (6.8%) and 1 with listhesis (2%) required repeat operation at 1 year. The overall 1-year follow-up rate was 88%. At 30 days, both lumbar discectomy and single-level fusion procedures were associated with significant improvements in ODI, visual analog scale, and SF-36 scores (p = 0.0002), which persisted at the 1-year evaluation (p spondylolisthesis. One-year cost per QALY was obtained, and this cost per QALY is expected to improve further by 2 years. This work sets the stage for real-world analysis of the value of health interventions.

  19. LHC Magnet test failure

    CERN Multimedia

    2007-01-01

    "On Tueday, March 22, a Fermilab-built quadrupole magnet, one of an "inner triplet" of three focusing magnets, failed a high-pressure test at Point 5 in the tunnel of the LHC accelerator at CERN. Since Tuesday, teams at CERN and Fermilab have worked closely together to address the problem and have identified the cause of the failure. Now they are at work on a solution.:" (1 page)

  20. Effect of Administration of Single Dose GnRH Agonist in Luteal Phase on Outcome of ICSI-ET Cycles in Women with Previous History of IVF/ICSI Failure: A Randomized Controlled Trial

    Science.gov (United States)

    Zafardoust, Simin; Jeddi-Tehrani, Mahmood; Akhondi, Mohammad Mehdi; Sadeghi, Mohammad Reza; Kamali, Koroush; Mokhtar, Sara; Badehnoosh, Bita; Arjmand-Teymouri, Fatemeh; Fatemi, Farnaz; Mohammadzadeh, Afsaneh

    2015-01-01

    Background GnRH agonist administration in the luteal phase has been suggested to beneficially affect the outcome of intracytoplasmic sperm injection (ICSI) and embryo transfer (ET) cycles. This blind randomized controlled study evaluates the effect of GnRH (Gonadotropine Releasing Hormone) agonist administration on ICSI outcome in GnRH antagonist ovarian stimulation protocol in women with 2 or more previous IVF/ICSI-ET failures. Methods One hundred IVF failure women who underwent ICSI cycles and stimulated with GnRH antagonist ovarian stimulation protocol, were included in the study. Women were randomly assigned to intervention (received a single dose injection of GnRH agonist (0.1 mg of Decapeptil) subcutaneously 6 days after oocyte retrieval) and control (did not receive GnRH agonist) groups. Implantation and clinical pregnancy rates were the primary outcome measures. Results Although the age of women, the number of embryos transferred in the current cycle and the quality of the transferred embryos were similar in the two groups, there was a significantly higher rate of implantation (Mann Whitney test, p = 0.041) and pregnancy (32.6% vs. 12.5%, p = 0.030, OR = 3.3, 95%CI, 1.08 to 10.4) in the intervention group. Conclusion Our results suggested that, in addition to routine luteal phase support using progesterone, administration of 0.1 mg of Decapeptil 6 days after oocyte retrieval in women with previous history of 2 or more IVF/ICSI failures led to a significant improvement in implantation and pregnancy rates after ICSI following ovarian stimulation with GnRH antagonist protocol. PMID:25927026

  1. Reproductive Failure

    African Journals Online (AJOL)

    The need for the establishment of a Reproductive Failure. Clinic at Groote Schuur Hospital was considered long overdue, as it was felt that there were a number of high risk pregnancies continually being lost among the large volume of pregnant women attending the routine, busy and overcrowded antenatal clinics,. Various ...

  2. Failure Modes

    DEFF Research Database (Denmark)

    Jakobsen, K. P.; Burcharth, H. F.; Ibsen, Lars Bo

    1999-01-01

    The present appendix contains the derivation of ten different limit state equations divided on three different failure modes. Five of the limit state equations can be used independently of the characteristics of the subsoil, whereas the remaining five can be used for either drained or undrained...

  3. Power failure at CERN Meyrin site

    CERN Multimedia

    2006-01-01

    The power failure, which occured at 7:47 on the morning of Saturday 29 July, was caused by a short-circuit in a 66 kV substation on the Meyrin site. The automatic reconfiguration of the network did not work as planned for a number of reasons, all of which are now well understood. As a result all the normal power networks on the Meyrin site, for the SPS and the LHC general services, were down. The secured power supply on the Meyrin site is provided by a set of three diesel motor driven power generators. All three diesel engines started correctly, but only one power generator could be correctly engaged. The single power generator's diesel motor ran for 45 minutes but was stopped automatically due to a mechanical fault. The reasons for these failures are being investigated. At that point, the Meyrin site and LHC Point 1 did not have a secured power network. The secured power networks for all the other LHC points worked as expected with their local diesel generators. The normal power network for the SPS and LHC ...

  4. The Random Material Point Method

    NARCIS (Netherlands)

    Wang, B.; Vardon, P.J.; Hicks, M.A.

    2017-01-01

    The material point method is a finite element variant which allows the material, represented by a point-wise discretization, to move through the background mesh. This means that large deformations, such as those observed post slope failure, can be computed. By coupling this material level

  5. Kidney (Renal) Failure

    Science.gov (United States)

    ... Physician Resources Professions Site Index A-Z Kidney Failure Kidney failure, also known as renal failure, is ... is kidney failure treated? What is kidney (renal) failure? The kidneys are designed to maintain proper fluid ...

  6. Muscle power failure in mobility-limited older adults: preserved single fiber function despite lower whole muscle size, quality and rate of neuromuscular activation.

    Science.gov (United States)

    Reid, Kieran F; Doros, Gheorghe; Clark, David J; Patten, Carolynn; Carabello, Robert J; Cloutier, Gregory J; Phillips, Edward M; Krivickas, Lisa S; Frontera, Walter R; Fielding, Roger A

    2012-06-01

    This study investigated the physiological and gender determinants of the age-related loss of muscle power in 31 healthy middle-aged adults (aged 40-55 years), 28 healthy older adults (70-85 years) and 34 mobility-limited older adults (70-85 years). We hypothesized that leg extensor muscle power would be significantly lower in mobility-limited elders relative to both healthy groups and sought to characterize the physiological mechanisms associated with the reduction of muscle power with aging. Computed tomography was utilized to assess mid-thigh body composition and calculate specific muscle power and strength. Surface electromyography was used to assess rate of neuromuscular activation and muscle biopsies were taken to evaluate single muscle fiber contractile properties. Peak muscle power, strength, muscle cross-sectional area, specific muscle power and rate of neuromuscular activation were significantly lower among mobility-limited elders compared to both healthy groups (P ≤ 0.05). Mobility-limited older participants had greater deposits of intermuscular adipose tissue (P mobility-limited elders relative to both healthy groups. Male gender was associated with greater decrements in peak and specific muscle power among mobility-limited participants. Impairments in the rate of neuromuscular activation and concomitant reductions in muscle quality are important physiological mechanisms contributing to muscle power deficits and mobility limitations. The dissociation between age-related changes at the whole muscle and single fiber level suggest that, even among older adults with overt mobility problems, contractile properties of surviving muscle fibers are preserved in an attempt to maintain overall muscle function.

  7. Development and Positioning Accuracy Assessment of Single-Frequency Precise Point Positioning Algorithms by Combining GPS Code-Pseudorange Measurements with Real-Time SSR Corrections

    Directory of Open Access Journals (Sweden)

    Miso Kim

    2017-06-01

    Full Text Available We have developed a suite of real-time precise point positioning programs to process GPS pseudorange observables, and validated their performance through static and kinematic positioning tests. To correct inaccurate broadcast orbits and clocks, and account for signal delays occurring from the ionosphere and troposphere, we applied State Space Representation (SSR error corrections provided by the Seoul Broadcasting System (SBS in South Korea. Site displacements due to solid earth tide loading are also considered for the purpose of improving the positioning accuracy, particularly in the height direction. When the developed algorithm was tested under static positioning, Kalman-filtered solutions produced a root-mean-square error (RMSE of 0.32 and 0.40 m in the horizontal and vertical directions, respectively. For the moving platform, the RMSE was found to be 0.53 and 0.69 m in the horizontal and vertical directions.

  8. Etiological Peculiarities in Pediatric Heart Failure

    OpenAIRE

    Angela, Butnariu; Gabriel, Samasca

    2015-01-01

    Heart failure in children presents important characteristic features different from adult congestive failure, from a pathophysiological and mostly from an etiopathogenic point of view. Heart failure in children is, in most cases, a consequence of congenital structural cardiac abnormalities that remained unoperated, underwent a palliative operation or presented post-surgery complications, or of cardiomyopathy. Based on the nature of the clinical presentation, new onset heart failure can be dif...

  9. Failure Analysis

    International Nuclear Information System (INIS)

    Iorio, A.F.; Crespi, J.C.

    1987-01-01

    After ten years of operation at the Atucha I Nuclear Power Station a gear belonging to a pressurized heavy water reactor refuelling machine, failed. The gear box was used to operate the inlet-outlet heavy-water valve of the machine. Visual examination of the gear device showed an absence of lubricant and that several gear teeth were broken at the root. Motion was transmitted with a speed-reducing device with controlled adjustable times in order to produce a proper fitness of the valve closure. The aim of this paper is to discuss the results of the gear failure analysis in order to recommend the proper solution to prevent further failures. (Author)

  10. Failure Assessment

    Science.gov (United States)

    Lutz, Robyn; Nikora, Allen

    2005-01-01

    Three questions to which software developers want accurate, precise answers are "How can the software system fail?", "mat bad things will happen if the software fails?t', and "How many failures will the software experience?". Numerous techniques have been devised to answer these questions; three of the best known are: 1) Software Fault Tree Analysis (SFTA) 2) Software Failure Modes, Effects, and Criticality Analysis (SFMECA 3) Software Fault/Failure Modeling. SFTA and SFMECA have been successfully used to analyze the flight software for a number of robotic planetary exploration missions, including Galileo, Cassini, and Deep Space 1. Given the increasing interest in reusing software components from mission to mission, one of us has developed techniques for reusing the corresponding portions of the SFTA and SFMECA, reducing the effort required to conduct these analyses. SFTA has also been shown to be effective in analyzing the security aspects of software systems; intrusion mechanisms and effects can easily be modeled using these techniques. The Bi- Directional Safety Analysis (BDSA) method combines a forward search (similar to SFMECA) from potential failure modes to their effects, with a backward search (similar to SFTA) from feasible hazards to the contributing causes of each hazard. BDSA offers an efficient way to identify latent failures. Recent work has extended BDSA to product-line applications such as flight-instrumentation displays and developed tool support for the reuse of the failure-analysis artifacts within a product line. BDSA has also been streamlined to support those projects having tight cost and/or schedule constraints for their failure analysis efforts. We discuss lessons learned from practice, describe available tools, and identi@ some future directions for the topic. A substantial amount of research has been devoted to estimating the number of failures that a software system will experience during test and operations, as well as the number of

  11. Structure-Guided, Single-Point Modifications in the Phosphinic Dipeptide Structure Yield Highly Potent and Selective Inhibitors of Neutral Aminopeptidases

    Energy Technology Data Exchange (ETDEWEB)

    Vassiliou, Stamatia; Węglarz-Tomczak, Ewelina; Berlicki, Łukasz; Pawełczak, Małgorzata; Nocek, Bogusław; Mulligan, Rory; Joachimiak, Andrzej; Mucha, Artur

    2014-10-09

    Seven crystal structures of alanyl aminopeptidase from Neisseria meningitides (the etiological agent of meningitis, NmAPN) complexed with organophosphorus compounds were resolved to determine the optimal inhibitor-enzyme interactions. The enantiomeric phosphonic acid analogs of Leu and hPhe, which correspond to the P1 amino acid residues of well-processed substrates, were used to assess the impact of the absolute configuration and the stereospecific hydrogen bond network formed between the aminophosphonate polar head and the active site residues on the binding affinity. For the hPhe analog, an imperfect stereochemical complementarity could be overcome by incorporating an appropriate P1 side chain. The constitution of P1'-extended structures was rationally designed and the lead, phosphinic dipeptide hPhePψ[CH2]Phe, was modified in a single position. Introducing a heteroatom/heteroatom-based fragment to either the P1 or P1' residue required new synthetic pathways. The compounds in the refined structure were low nanomolar and subnanomolar inhibitors of N. meningitides, porcine and human APNs, and the reference leucine aminopeptidase (LAP). The unnatural phosphinic dipeptide analogs exhibited a high affinity for monozinc APNs associated with a reasonable selectivity versus dizinc LAP. Another set of crystal structures containing the NmAPN dipeptide ligand were used to verify and to confirm the predicted binding modes; furthermore, novel contacts, which were promising for inhibitor development, were identified, including a π-π stacking interaction between a pyridine ring and Tyr372.

  12. Accurate approach for determining fresh-water carbonate (H2CO3(*)) alkalinity, using a single H3PO4 titration point.

    Science.gov (United States)

    Birnhack, Liat; Sabach, Sara; Lahav, Ori

    2012-10-15

    A new, simple and accurate method is introduced for determining H(2)CO(3)(*) alkalinity in fresh waters dominated by the carbonate weak-acid system. The method relies on a single H(3)PO(4) dosage and two pH readings (acidic pH value target: pH~4.0). The computation algorithm is based on the concept that the overall alkalinity mass of a solution does not change upon the addition of a non-proton-accepting species. The accuracy of the new method was assessed batch-wise with both synthetic and actual tap waters and the results were compared to those obtained from two widely used alkalinity analysis methods (titration to pH~4.5 and the Gran titration method). The experimental results, which were deliberately obtained with simple laboratory equipment (glass buret, general-purpose pH electrode, magnetic stirrer) proved the method to be as accurate as the conventional methods at a wide range of alkalinity values (20-400 mg L(-1) as CaCO(3)). Analysis of the relative error attained in the proposed method as a function of the target (acidic) pH showed that at the range 4.0pHalkalinity measurement is also described. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. SAAFEC: Predicting the Effect of Single Point Mutations on Protein Folding Free Energy Using a Knowledge-Modified MM/PBSA Approach.

    Science.gov (United States)

    Getov, Ivan; Petukh, Marharyta; Alexov, Emil

    2016-04-07

    Folding free energy is an important biophysical characteristic of proteins that reflects the overall stability of the 3D structure of macromolecules. Changes in the amino acid sequence, naturally occurring or made in vitro, may affect the stability of the corresponding protein and thus could be associated with disease. Several approaches that predict the changes of the folding free energy caused by mutations have been proposed, but there is no method that is clearly superior to the others. The optimal goal is not only to accurately predict the folding free energy changes, but also to characterize the structural changes induced by mutations and the physical nature of the predicted folding free energy changes. Here we report a new method to predict the Single Amino Acid Folding free Energy Changes (SAAFEC) based on a knowledge-modified Molecular Mechanics Poisson-Boltzmann (MM/PBSA) approach. The method is comprised of two main components: a MM/PBSA component and a set of knowledge based terms delivered from a statistical study of the biophysical characteristics of proteins. The predictor utilizes a multiple linear regression model with weighted coefficients of various terms optimized against a set of experimental data. The aforementioned approach yields a correlation coefficient of 0.65 when benchmarked against 983 cases from 42 proteins in the ProTherm database. the webserver can be accessed via http://compbio.clemson.edu/SAAFEC/.

  14. High genetic homogeneity points to a single introduction event responsible for invasion of Cotton leaf curl Multan virus and its associated betasatellite into China.

    Science.gov (United States)

    Du, Zhenguo; Tang, Yafei; He, Zifu; She, Xiaoman

    2015-10-07

    Cotton leaf curl Multan virus (CLCuMuV) is a Whitefly Transmitted Geminivirus (WTG) endemic to the India subcontinent and is notorious as a causal agent of cotton leaf curl disease (CLCuD), a major constraint to cotton production in south Asia. We found CLCuMuV infecting Hibiscus rosa-sinensis in Guangzhou, China in 2006. The spread and evolution of the invading CLCuMuV were monitored in the following nine years. CLCuMuV spread rapidly in the last nine years and became established in Southern China. It infects at least five malvaceous plant species, H. rosa-sinensis, H. esculentus, Malvaiscus arboreus, Gossypium hirsutum and H. cannabinus. Complete nucleotide sequences of 34 geographically and/or temporally distinct CLCuMuV isolates were determined and analyzed together with six other publicly available genomes of CLCuMuV occurring in China. The 40 CLCuMuV isolates were found to share > 99 % nucleotide sequence identity with each other. In all cases tested, the CLCuMuVs were associated with a CLCuMuB. The 36 CLCuMuBs (30 sequenced by us) shared > 98 % nucleotide sequence identity. The high genetic homogeneity of CLCuMuV and CLCuMuB in China suggests the establishment of them from a single founder event.

  15. Balance failure in single limb stance due to ankle sprain injury: an analysis of center of pressure using the fractal dimension method.

    Science.gov (United States)

    Doherty, Cailbhe; Bleakley, Chris; Hertel, Jay; Caulfield, Brian; Ryan, John; Delahunt, Eamonn

    2014-01-01

    Instrumented postural control analysis plays an important role in evaluating the effects of injury on dynamic stability during balance tasks, and is often conveyed with measures based on the displacement of the center-of-pressure (COP) assessed with a force platform. However, the desired outcome of the task is frequently characterized by a loss of dynamic stability, secondary to injury. Typically, these failed trials are discarded during research investigations, with the potential loss of informative data pertaining to task success. The novelty of the present study is that COP characteristics of failed trials in injured participants are compared to successful trial data in another injured group, and a control group of participants, using the fractal dimension (FD) method. Three groups of participants attempted a task of eyes closed single limb stance (SLS): twenty-nine participants with acute ankle sprain successfully completed the task on their non-injured limb (successful injury group); twenty eight participants with acute ankle sprain failed their attempt on their injured limb (failed injury group); sixteen participants with no current injury successfully completed the task on their non-dominant limb (successful non-injured group). Between trial analyses of these groups revealed significant differences in COP trajectory FD (successful injury group: 1.58±0.06; failed injury group: 1.54±0.07; successful non-injured group: 1.64±0.06) with a large effect size (0.27). These findings demonstrate that successful eyes-closed SLS is characterized by a larger FD of the COP path when compared to failed trials, and that injury causes a decrease in COP path FD. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Risk factors and outcomes for catastrophic failures at the top of long pedicle screw constructs: a matched cohort analysis performed at a single center.

    Science.gov (United States)

    O'Leary, Patrick T; Bridwell, Keith H; Lenke, Lawrence G; Good, Christopher R; Pichelmann, Mark A; Buchowski, Jacob M; Kim, Yongjung J; Flynn, Jennifer

    2009-09-15

    Retrospective review with matched-cohort analysis performed at a single institution. To determine risk factors and outcomes for acute fractures at the proximal aspect of long pedicle screw constructs. Acute fractures at the top of long segmental pedicle screw constructs (FPSC) can be catastrophic. Substantial surgical increase in lordosis may precipitate this problem. In relation to a matched cohort, we postulated that age, body mass index (BMI), and significant correction of lumbar lordosis would increase risk of FPSC and patients with FPSC would have lesser improvements in outcomes. Thirteen patients who sustained FPSC between 2000 and 2007 were evaluated. During this time, 264 patients aged 40 or older had a spinal fusion from the thoracic spine to the sacrum using an all-pedicle screw construct. A cohort of 31 of these patients without FPSC but with all pedicle screw constructs was matched for diagnosis of positive sagittal imbalance, gender, preoperative C7 sagittal plumb, and number of levels fused. There was a significant difference in age (P = 0.02) and BMI (P = 0.006) between the matched groups. There was no significant difference in preoperative/postoperative C7 plumb or change in lumbar lordosis between groups. Acute neurological deficit developed in 2 patients; both patients improved substantially after revision surgery. Nine patients underwent proximal extension of the fusion. For 7 of the 13 FPSC patients with bone mineral density data (BMD) available, average T score was-1.73; -0.58 for the matched group (10/31 with bone mineral density data) (P = 0.02). Factors that increased the risk of FPSC included obesity and older age. Osteopenia increased the risk as evidenced by BMD (based on 17 patients) and the older age of these patients. There was no statistical difference in clinical improvement between groups based on ODI, but the FPSC group did demonstrate a smaller improvement in ODI score than the matched cohort.

  17. Tipping Point

    Medline Plus

    Full Text Available ... OnSafety CPSC Stands for Safety The Tipping Point Home > 60 Seconds of Safety (Videos) > The Tipping Point ... 24 hours a day. For young children whose home is a playground, it’s the best way to ...

  18. Fixed Points

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 5; Issue 5. Fixed Points - From Russia with Love - A Primer of Fixed Point Theory. A K Vijaykumar. Book Review Volume 5 Issue 5 May 2000 pp 101-102. Fulltext. Click here to view fulltext PDF. Permanent link:

  19. Rapid MR assessment of left ventricular systolic function after acute myocardial infarction using single breath-hold cine imaging with the temporal parallel acquisition technique (TPAT) and 4D guide-point modelling analysis of left ventricular function

    International Nuclear Information System (INIS)

    Eberle, Holger C.; Jensen, Christoph J.; Sabin, Georg V.; Naber, Christoph K.; Bruder, Oliver; Nassenstein, Kai; Schlosser, Thomas

    2010-01-01

    We compared four-dimensional guide-point modelling left ventricular function analysis (4DVF) results of cine images in four short-axis and two long-axis slices acquired in a single breath-hold, obtained with the temporal parallel acquisition technique (TPAT), with standard left ventricular function (LVF) analysis results determined by the summation of discs method, in patients who had recently suffered myocardial infarction. Despite wall motion abnormalities, 4DVF yields results for left ventricular ejection fractions and end-diastolic and end-systolic volumes that are in excellent agreement with standard LVF analysis results in these patients. A shortened cardiac magnetic resonance (CMR) protocol using single breath-hold cine image acquisition could facilitate the assessment of left ventricular function soon after myocardial infarction in critically ill patients who are unable to comply with the multiple breath-holds required for standard LVF analysis. (orig.)

  20. Heart failure - tests

    Science.gov (United States)

    CHF - tests; Congestive heart failure - tests; Cardiomyopathy - tests; HF - tests ... best test to: Identify which type of heart failure (systolic, diastolic, valvular) Monitor your heart failure and ...

  1. Predicting Failure Progression and Failure Loads in Composite Open-Hole Tension Coupons

    Science.gov (United States)

    Arunkumar, Satyanarayana; Przekop, Adam

    2010-01-01

    Failure types and failure loads in carbon-epoxy [45n/90n/-45n/0n]ms laminate coupons with central circular holes subjected to tensile load are simulated using progressive failure analysis (PFA) methodology. The progressive failure methodology is implemented using VUMAT subroutine within the ABAQUS(TradeMark)/Explicit nonlinear finite element code. The degradation model adopted in the present PFA methodology uses an instantaneous complete stress reduction (COSTR) approach to simulate damage at a material point when failure occurs. In-plane modeling parameters such as element size and shape are held constant in the finite element models, irrespective of laminate thickness and hole size, to predict failure loads and failure progression. Comparison to published test data indicates that this methodology accurately simulates brittle, pull-out and delamination failure types. The sensitivity of the failure progression and the failure load to analytical loading rates and solvers precision is demonstrated.

  2. Advantages of conducting in-situ U-Pb age dating of multiple U-bearing minerals from a single complex: Case in point - the Oka Carbonatite Complex

    Science.gov (United States)

    Chen, W.; Simonetti, A.

    2012-12-01

    sample. The niocalite for a carbonatite sample Oka153 defines a bimodal age distribution, with weighted average 206Pb/238U ages of 110.1 ±5.0 and 133.2 ±6.1 Ma. Apatite from the same sample also records a similar bimodal age distribution of 111.4 ±2.8 and 126.9 ±1.8 Ma. The combined in situ U-Pb dating results for apatite, pervoskite, niocalite from Oka clearly support a protracted history of magmatic activity (~30 Myr) for this carbonatite complex. Of importance, the U-Pb results from this study clearly indicate the significance of conducting a thorough geochronological investigation rather than defining the age of any one alkaline complex solely on the basis of a single radiometric age determination.

  3. Tipping Point

    Medline Plus

    Full Text Available ... Point by CPSC Blogger September 22, 2009 appliance child Childproofing CPSC danger death electrical fall furniture head ... see news reports about horrible accidents involving young children and furniture, appliance and tv tip-overs. The ...

  4. B-type natriuretic peptide as predictor of heart failure in patients with acute ST elevation myocardial infarction, single-vessel disease, and complete revascularization: follow-up study.

    LENUS (Irish Health Repository)

    Manola, Sime

    2012-01-31

    AIM: To assess the concentration of B-type natriuretic peptide (BNP) as a predictor of heart failure in patients with acute ST elevation myocardial infarction (STEMI) who underwent primary percutaneous coronary intervention (PCI) with successful and complete revascularization. METHODS: Out of a total of 220 patients with acute STEMI admitted to the Sisters of Mercy University Hospital in the period January 1 to December 31, 2007, only patients with acute STEMI undergoing primary PCI who had single vessel disease and were successfully revascularized were included in the study. Selected patients had no history of myocardial infarction or heart failure and a normal or near-normal left ventricular ejection fraction (> or =50%) assessed by left ventriculography at admission. Only 58 patients met the inclusion criteria for the study. Out of those, 6 patients refused to participate in the study, and another 5 could not be followed up, so a total of 47 patients were evaluated. Blood samples were taken for measurement of BNP levels at admission, 24 hours later, and 7 days later. Patients were followed up for 1 year. The primary outcome was reduction in left ventricular ejection fraction (LVEF) to <50% after 1 year. RESULTS: Patients who developed echocardiographic signs of reduced systolic function defined as LVEF<50% had significantly higher values of BNP (> or =80 pg\\/mL) at 24 hours (P=0.001) and 7 days (P=0.020) after STEMI and successful reperfusion. Patients who had BNP levels > or =80 pg\\/mL after 7 days were 21 times more likely to develop LVEF<50 (odds ratio, 20.8; 95% confidence interval, 2.2-195.2; P=0.008). CONCLUSION: BNP can be used as a predictor of reduced systolic function in patients with STEMI who underwent successful reperfusion and had normal ejection fraction at admission.

  5. Analysis of failures in concrete containments

    International Nuclear Information System (INIS)

    Moreno-Gonzalez, A.

    1989-09-01

    The function of Containment, in an accident event, is to avoid the release of radioactive substances into the surroundings. Containment failure, therefore, is defined as the appearance of leak paths to the external environment. These leak paths may appear either as a result of loss of leaktightness due to degradation of design conditions or structural failure with containment material break. This document is a survey of the state of the art of Containment Failure Analysis. It gives a detailed description of all failure mechanisms, indicating all the possible failure modes and their causes, right from failure resulting from degradation of the materials to structural failure and linear breake failure. Following the description of failure modes, possible failure criteria are identified, with special emphasis on structural failure criteria. These criteria have been obtained not only from existing codes but also from the latest experimental results. A chapter has been dedicated exclusively to failure criteria in conventional structures, for the purpose of evaluating the possibility of application to the case of containment. As the structural behaviour of the containment building is very complex, it is not possible to define failure through a single parameter. It is therefore advisable to define a methodology for containment failure analysis which could be applied to a particular containment. This methodology should include prevailing load and material conditions together with the behaviour of complex conditions such as the liner-anchorage-cracked concrete interaction

  6. Investigación de la unión soldada entre el vástago y las placas de las cuchillas calzadas // Investigation of the welded joint between plates and tipped single-point lathe tools

    Directory of Open Access Journals (Sweden)

    M. Jacas Cabrera

    2000-01-01

    Full Text Available El presente trabajo está dirigido al incremento de los niveles de producción y calidad, específicamente en la línea defabricación de cuchillas calzadas para torno en el centro fabril “Miguel Saavedra” HERRAMIX.En este caso se realizó un análisis para la sustitución de las pastillas de soldar, fabricadas por CIME por nuevastrimetálicas.En el mismo se determinaron los tiempos de calentamiento necesarios para realizar la soldadura, en las máquinas deinducción (TBCHE, así como los valores de resistencia al cizallamiento de los calzos una vez soldados.Palabras claves: Cuchillas de punta, calzos metalo-ceramicos, placas trimetálicas_____________________________________________________________________Abstract:The present work is directed to increase the production and quality levels of tipped single-point lathe tools at “MiguelSaavedra” plant HERRAMIX.This work deals with a study about the substitution of brazing-pads made by CIME for tri-metallic new ones.The induction brazing heating time’s necessaries at induction machines (TBCHE as well as shear-stress values at the tips afterwelding are determined.Key words: tip single point lathe tool, metal ceramic plate, trimetallic pads.

  7. Acute kidney failure

    Science.gov (United States)

    Kidney failure; Renal failure; Renal failure - acute; ARF; Kidney injury - acute ... Symptoms of acute kidney failure may include any of the following: Bloody stools Breath odor and metallic taste in the mouth Bruising easily Changes in ...

  8. Types of Heart Failure

    Science.gov (United States)

    ... Venous Thromboembolism Aortic Aneurysm More Types of Heart Failure Updated:May 8,2017 Left-sided heart failure ... This content was last reviewed May 2017. Heart Failure • Home • About Heart Failure Introduction Types of Heart ...

  9. Randomized, open-label, blinded-endpoint, crossover, single-dose study to compare the pharmacodynamics of torasemide-PR 10 mg, torasemide-IR 10 mg, and furosemide-IR 40 mg, in patients with chronic heart failure

    Science.gov (United States)

    Ballester, Maria Rosa; Roig, Eulàlia; Gich, Ignasi; Puntes, Montse; Delgadillo, Joaquín; Santos, Benjamín; Antonijoan, Rosa Maria

    2015-01-01

    Purpose Diuretics are the primary treatment for the management of chronic heart failure (HF) symptoms and for the improvement of acute HF symptoms. The rate of delivery to the site of action has been suggested to affect diuretic pharmacodynamics. The main objective of this clinical trial was to explore whether a prolonged release tablet formulation of torasemide (torasemide-PR) was more natriuretically efficient in patients with chronic HF compared to immediate-release furosemide (furosemide-IR) after a single-dose administration. Moreover, the pharmacokinetics of torasemide-PR, furosemide-IR, and torasemide-IR were assessed in chronic HF patients as well as urine pharmacodynamics. Methods Randomized, open-label, blinded-endpoint, crossover, and single-dose Phase I clinical trial with three experimental periods. Torasemide-PR and furosemide-IR were administered as a single dose in a crossover fashion for the first two periods, and torasemide-IR 10 mg was administered for the third period. Blood and urine samples were collected at fixed timepoints. The primary endpoint was the natriuretic efficiency after administration of torasemide-PR and furosemide-IR, defined as the ratio between the average drug-induced natriuresis and the average drug recovered in urine over 24 hours. Results Ten patients were included and nine completed the study. Here, we present the results from nine patients. Torasemide-PR was more natriuretically efficient than furosemide-IR (0.096±0.03 mmol/μg vs 0.015±0.0007 mmol/μg; P<0.0001). Mictional urgency was lower and more delayed with torasemide-PR than with furosemide-IR. Conclusion In a study with a limited sample size, our results suggest that 10 mg of torasemide-PR is more natriuretically efficient than 40 mg of furosemide-IR after single-dose administration in patients with chronic HF over a 24-hour collection period. Further studies are necessary to evaluate potential pharmacodynamic differences between torasemide formulations and to

  10. Contextualizing Genetics for Regional Heart Failure Care.

    Science.gov (United States)

    Iyngkaran, Pupalan; Thomas, Merlin C; Johnson, Renee; French, John; Ilton, Marcus; McDonald, Peter; Hare, David L; Fatkin, Diane

    Congestive heart failure (CHF) is a chronic and often devastating cardiovascular disorder with no cure. There has been much advancement in the last two decades that has seen improvements in morbidity and mortality. Clinicians have also noted variations in the responses to therapies. More detailed observations also point to clusters of diseases, phenotypic groupings, unusual severity and the rates at which CHF occurs. Medical genetics is playing an increasingly important role in answering some of these observations. This developing field in many respects provides more information than is currently clinically applicable. This includes making sense of the established single gene mutations or uncommon private mutations. In this thematic series which discusses the many factors that could be relevant for CHF care, once established treatments are available in the communities; this section addresses a contextual role for medical genetics.

  11. Scalable single point power extraction for compact mobile and stand-alone solar harvesting power sources based on fully printed organic photovoltaic modules and efficient high voltage DC/DC conversion

    DEFF Research Database (Denmark)

    Garcia Valverde, Rafael; Villarejo, José A.; Hösel, Markus

    2015-01-01

    Patterns for fully printed polymer solar cells are presented that inherently enable scaling of the power output with single point electrical energy connection is presented. Connection is made to only one end of the printed foil that can be rolled out for light energy harvesting. The power level...... (AM1.5G, 1000 W m−2). As a demonstration we present a scalable fully integrated and compact power unit for mobile applications comprising solar energy harvesting OPV modules, power conversion and storage. Applications possible include electrical charging of mobile devices, illumination using LED lamps...... takes place in a HVDC–DC converter that is tailored specifically for operation with polymer solar cells by regulation on the input side. The system charges a lithium-polymer battery thus enabling storage of 82 Wh for a printed OPV foil measuring 0.305 m×9 m having a nominal power output of at least 15 W...

  12. Is It Possible to Detect Activated Brown Adipose Tissue in Humans Using Single-Time-Point Infrared Thermography under Thermoneutral Conditions? Impact of BMI and Subcutaneous Adipose Tissue Thickness.

    Science.gov (United States)

    Gatidis, Sergios; Schmidt, Holger; Pfannenberg, Christina A; Nikolaou, Konstantin; Schick, Fritz; Schwenzer, Nina F

    2016-01-01

    To evaluate the feasibility to detect activated brown adipose tissue (BAT) using single-time-point infrared thermography of the supraclavicular skin region under thermoneutral conditions. To this end, infrared thermography was compared with 18-F-FDG PET, the current reference standard for the detection of activated BAT. 120 patients were enrolled in this study. After exclusion of 18 patients, 102 patients (44 female, 58 male, mean age 58±17 years) were included for final analysis. All patients underwent a clinically indicated 18F-FDG-PET/CT examination. Immediately prior to tracer injection skin temperatures of the supraclavicular, presternal and jugular regions were measured using spatially resolved infrared thermography at room temperature. The presence of activated BAT was determined in PET by typical FDG uptake within the supraclavicular adipose tissue compartments. Local thickness of supraclavicular subcutaneous adipose tissue (SCAT) was measured on CT. Measured skin temperatures were statistically correlated with the presence of activated BAT and anthropometric data. Activated BAT was detected in 9 of 102 patients (8.8%). Local skin temperature of the supraclavicular region was significantly higher in individuals with active BAT compared to individuals without active BAT. However, after statistical correction for the influence of BMI, no predictive value of activated BAT on skin temperature of the supraclavicular region could be observed. Supraclavicular skin temperature was significantly negatively correlated with supraclavicular SCAT thickness. We conclude that supraclavicular SCAT thickness influences supraclavicular skin temperature and thus makes a specific detection of activated BAT using single-time-point thermography difficult. Further studies are necessary to evaluate the possibility of BAT detection using alternative thermographic methods, e.g. dynamic thermography or MR-based thermometry taking into account BMI as a confounding factor.

  13. Is It Possible to Detect Activated Brown Adipose Tissue in Humans Using Single-Time-Point Infrared Thermography under Thermoneutral Conditions? Impact of BMI and Subcutaneous Adipose Tissue Thickness.

    Directory of Open Access Journals (Sweden)

    Sergios Gatidis

    Full Text Available To evaluate the feasibility to detect activated brown adipose tissue (BAT using single-time-point infrared thermography of the supraclavicular skin region under thermoneutral conditions. To this end, infrared thermography was compared with 18-F-FDG PET, the current reference standard for the detection of activated BAT.120 patients were enrolled in this study. After exclusion of 18 patients, 102 patients (44 female, 58 male, mean age 58±17 years were included for final analysis. All patients underwent a clinically indicated 18F-FDG-PET/CT examination. Immediately prior to tracer injection skin temperatures of the supraclavicular, presternal and jugular regions were measured using spatially resolved infrared thermography at room temperature. The presence of activated BAT was determined in PET by typical FDG uptake within the supraclavicular adipose tissue compartments. Local thickness of supraclavicular subcutaneous adipose tissue (SCAT was measured on CT. Measured skin temperatures were statistically correlated with the presence of activated BAT and anthropometric data.Activated BAT was detected in 9 of 102 patients (8.8%. Local skin temperature of the supraclavicular region was significantly higher in individuals with active BAT compared to individuals without active BAT. However, after statistical correction for the influence of BMI, no predictive value of activated BAT on skin temperature of the supraclavicular region could be observed. Supraclavicular skin temperature was significantly negatively correlated with supraclavicular SCAT thickness.We conclude that supraclavicular SCAT thickness influences supraclavicular skin temperature and thus makes a specific detection of activated BAT using single-time-point thermography difficult. Further studies are necessary to evaluate the possibility of BAT detection using alternative thermographic methods, e.g. dynamic thermography or MR-based thermometry taking into account BMI as a confounding factor.

  14. Single point mutations in the helicase domain of the NS3 protein enhance dengue virus replicative capacity in human monocyte-derived dendritic cells and circumvent the type I interferon response.

    Science.gov (United States)

    Silveira, G F; Strottmann, D M; de Borba, L; Mansur, D S; Zanchin, N I T; Bordignon, J; dos Santos, C N Duarte

    2016-01-01

    Dengue is the most prevalent arboviral disease worldwide. The outcome of the infection is determined by the interplay of viral and host factors. In the present study, we evaluated the cellular response of human monocyte-derived DCs (mdDCs) infected with recombinant dengue virus type 1 (DV1) strains carrying a single point mutation in the NS3hel protein (L435S or L480S). Both mutated viruses infect and replicate more efficiently and produce more viral progeny in infected mdDCs compared with the parental, non-mutated virus (vBACDV1). Additionally, global gene expression analysis using cDNA microarrays revealed that the mutated DVs induce the up-regulation of the interferon (IFN) signalling and pattern recognition receptor (PRR) canonical pathways in mdDCs. Pronounced production of type I IFN were detected specifically in mdDCs infected with DV1-NS3hel-mutated virus compared with mdDCs infected with the parental virus. In addition, we showed that the type I IFN produced by mdDCs is able to reduce DV1 infection rates, suggesting that cytokine function is effective but not sufficient to mediate viral clearance of DV1-NS3hel-mutated strains. Our results demonstrate that single point mutations in subdomain 2 have important implications for adenosine triphosphatase (ATPase) activity of DV1-NS3hel. Although a direct functional connection between the increased ATPase activity and viral replication still requires further studies, these mutations speed up viral RNA replication and are sufficient to enhance viral replicative capacity in human primary cell infection and circumvent type I IFN activity. This information may have particular relevance for attenuated vaccine protocols designed for DV. © 2015 British Society for Immunology.

  15. Development in fracture mechanics and failure assessment

    International Nuclear Information System (INIS)

    Chell, G.G.

    1978-01-01

    Application of the theories of fracture mechanics can help avoid the type of catastrophic failure that has occurred in structures, eg the failure, whilst undergoing a routine test, of a turbogenerator for Hinkly Point power station. The development is described for a procedure for summarising the salient features of fracture theory as applied to steel structures. This is achieved by the introduction of a relatively simple failure assessment diagram which may be used by unspecialised staff. (author)

  16. Failure Detector for Power-Factor Controller

    Science.gov (United States)

    Nola, F. J.

    1982-01-01

    New protective circuits have been developed for power-factor ac motor controllers. Circuits prevent direct current and consequent motor heating that would normally result from failure of solid-state switch in controller. Single-phase power-factor controller with short detector compensates for short-circuit failure in either direction by applying full power to motor. Controller with open detector compensates for open-circuit failure in either direction by turning off power to motor.

  17. Procalcitonin for selecting the antibiotic regimen in outpatients with low-risk community-acquired pneumonia using a rapid point-of-care testing: A single-arm clinical trial

    Science.gov (United States)

    Masiá, Mar; Padilla, Sergio; Ortiz de la Tabla, Victoria; González, Matilde; Bas, Cristina; Gutiérrez, Félix

    2017-01-01

    Objective We aimed to assess the role of procalcitonin (PCT) to guide the initial selection of the antibiotic regimen for low-risk community-acquired pneumonia (CAP). Methods A single-arm clinical trial was conducted including outpatients with CAP and Pneumonia Severity Index risk classes I-II. Antimicrobial selection was based on the results of PCT measured with a rapid point-of-care testing. According to serum PCT levels, patients were assigned to two treatment strategies: oral azithromycin if PCT was Atypical organisms were more common in patients given azithromycin (18.5% vs 8.1%, respectively). The majority (93%) of patients with atypical pneumonia had low PCT levels. Clinical cure rates were 95.8% in the azithromycin group, 94.6% in the levofloxacin group, and 94.4% in the historical control group. No 30-day mortality or recurrences were observed, and the 3-year rates of recurrence and mortality were very low in both groups. Adverse events occurrence was also infrequent. Conclusion A PCT-guided strategy with a rapid point-of-care testing safely allowed selecting empirical narrow-spectrum antibiotics in outpatients with CAP. Trial registration The study is registered with ClinicalTrials.gov, number NCT02600806 PMID:28426811

  18. Do Foreign Language Learners Need Failures?

    Directory of Open Access Journals (Sweden)

    Joanna Kic-Drgas

    2016-06-01

    Full Text Available A lack of motivation, incomprehensible content and a high workload are only some of the causes leading to students’ failures in the learning process. Dealing with failures seems to have become a new core competence in the current world, which is why the definition and implementation of an appropriate strategy is essential for prospective learning results. The focus of the contribution is on the meaning of failure and sources of potential student failures in the foreign language learning at the university level. The results presented in the paper base on the survey conducted with English language students at Koszalin University of Technology. Students were asked to identify the field causing learning failures. The described survey delivers information about the sources of failures from learner’s point of view, which can be an incentive to develop and implement strategies to cope with failures in the ESP class.

  19. Efficacy and Safety of Single Botulinum Toxin Type A (Botox®) Injection for Relief of Upper Trapezius Myofascial Trigger Point: A Randomized, Double-Blind, Placebo-Controlled Study.

    Science.gov (United States)

    Kwanchuay, Photsawee; Petchnumsin, Thavatchai; Yiemsiri, Pichet; Pasuk, Nakkamol; Srikanok, Wannarat; Hathaiareerug, Chanasak

    2015-12-01

    Botulinum toxin injection has been applied for pain relief in various chronic pain syndromes. Recently, systematic review studies reported inconclusive effects of Botulinum toxin in myofascial pain management. The present study aimed to demonstrate the efficacy and safety of Botulinum toxin type A (BTxA) (Botox®) injection for pain reduction in myofascial trigger point (MTrP) of the upper trapezius muscle. Thirty-three patients with 48 MTrP on the upper trapezius muscles over three months with moderate to severe pain intensity diagnosed at physical medicine and rehabilitation outpatient department were recruited between December 2011 and March 2012. Eligible patients were blinded and randomly injected with single 0.2 ml (20 IU) of BTxA for 24 MTrP and 0.2 ml of 0.9% NaCl solution for 24 MTrP at the most tender trigger point on the upper trapezius muscle. All patients were advised for stretching exercise and ergonomic adaptation throughout the study. At 3- and 6-week after injections, visual analogue scale (VAS), the pressure pain threshold (PPT), and reported adverse effects were measured. Both BTxA and control groups demonstrated statistically significant differences in VAS reduction and increased PPT after 3 weeks and 6 weeks compared with before treatment. There were no statistically significant differences in VAS reduction from baseline between the two groups at 3- and 6-week after treatment. A statistically significant difference in improvement of PPT from baseline and 6-week after BTxA injection compared with 0.9% NaCl group was shown (1.0 ± 0.9 and 0.5 ± 0.7, p = 0.036). There was mild degree side-effects that spontaneous resolved within one week in both groups without significant difference in percentage. No severe adverse effects were reported during the study. The efficacy in VAS reduction of a single 20 IU of Botulinum toxin type A (Botox®) injection was not different from 0.9% NaCl for myofascial trigger point at the upper trapezius muscle. However

  20. 32 CFR 634.45 - Point system application.

    Science.gov (United States)

    2010-07-01

    .... Violation: Failure to stop for school bus or school-crossing signals. Points assessed: 4 Q. Violation... disregard for the safety of persons or property). Points assessed: 6 B. Violation: Owner knowingly and... traffic, causing potential safety hazard. Points assessed: 2 H. Violation: Failure of operator or...

  1. Collimator fast failure losses for various HL-LHC configurations

    CERN Document Server

    Lari, L; Redaelli, S

    2014-01-01

    The upgrade of the Large Hadron Collider (LHC), in terms of beam intensity and energy, implies an increasing risk of severe damage in particular in case of beam losses during fast failures. For this reason, efforts were put in developing simulation tools to allow studies of asynchronous dump accidents, including realistic additional failure scenarios. The scope of these studies is to understand realistic beam loads in different collimators, in order to improve the actual LHC collimation system design, to provide feedbacks on optics design and to elaborate different mitigation actions. Simulations were set up with a modified SixTrack collimation routine able to simulate erroneous firing of a single dump kicker or the simultaneous malfunction of all the 15 kickers. In such a context, results are evaluated from the whole LHC collimation system point of view.

  2. Technical evaluation of the susceptibility of safety-related systems to flooding caused by the failure of non-Category I systems for Turkey Point Nuclear Power Plant, Units 3 and 4

    International Nuclear Information System (INIS)

    Collins, E.K.

    1979-08-01

    Three separate reviews of the Turkey Point Units 3 and 4 were conducted by the FPLCO between 1972 and 1975. Initially, at the request of NBC in 1972, the FPLCO reviewed several water systems as sources of flooding. Subsequently, as a result of an abnormal occurrence, the drainage system was reviewed. Finally, the facilities were again reviewed at NRC's request and both the potential sources of flooding and safety-related equipment which could be damaged by flooding were identified. The sources of flooding and the appropriate safety equipment are discussed. An evaluation is presented of measures that were taken by FPLCO to minimize the danger of flooding and to protect safety-related equipment

  3. Revisiting Formability and Failure of AISI304 Sheets in SPIF: Experimental Approach and Numerical Validation

    OpenAIRE

    Centeno, Gabriel; Martínez-Donaire, Andrés Jesús; Bagudanch Frigolé, Isabel; Morales-Palma, Domingo; Garcia-Romeu, Maria Luisa; Vallellano, Carpóforo

    2017-01-01

    Single Point Incremental Forming (SPIF) is a flexible and economic manufacturing process with a strong potential for manufacturing small and medium batches of highly customized parts. Formability and failure in SPIF have been intensively discussed in recent years, especially because this process allows stable plastic deformation well above the conventional forming limits, as this enhanced formability is only achievable within a certain range of process parameters depending on the material typ...

  4. Multiple Failure Response Procedure System, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — When an ISHM module identifies a single failure, an associated response procedure, developed and validated in advance, can be selected for execution to verify the...

  5. Heart failure - medicines

    Science.gov (United States)

    CHF - medicines; Congestive heart failure - medicines; Cardiomyopathy - medicines; HF - medicines ... will need to take most of your heart failure medicines every day. Some medicines are taken once ...

  6. The failure-tolerant leader.

    Science.gov (United States)

    Farson, Richard; Keyes, Ralph

    2002-08-01

    "The fastest way to succeed," IBM's Thomas Watson, Sr., once said, "is to double your failure rate." In recent years, more and more executives have embraced Watson's point of view, coming to understand what innovators have always known: Failure is a prerequisite to invention. But while companies may grasp the value of making mistakes at the level of corporate practices, they have a harder time accepting the idea at the personal level. People are afraid to fail, and corporate culture reinforces that fear. In this article, psychologist and former Harvard Business School professor Richard Farson and coauthor Ralph Keyes discuss how companies can reduce the fear of miscues. What's crucial is the presence of failure-tolerant leaders--executives who, through their words and actions, help employees overcome their anxieties about making mistakes and, in the process, create a culture of intelligent risk-taking that leads to sustained innovation. Such leaders don't just accept productive failure, they promote it. Drawing from their research in business, politics, sports, and science, the authors identify common practices among failure-tolerant leaders. These leaders break down the social and bureaucratic barriers that separate them from their followers. They engage at a personal level with the people they lead. They avoid giving either praise or criticism, preferring to take a nonjudgmental, analytical posture as they interact with staff. They openly admit their own mistakes rather than trying to cover them up or shifting the blame. And they try to root out the destructive competitiveness built into most organizations. Above all else, failure-tolerant leaders push people to see beyond traditional definitions of success and failure. They know that as long as a person views failure as the opposite of success, rather than its complement, he or she will never be able to take the risks necessary for innovation.

  7. Factors contributing to migraine headache surgery failure and success.

    Science.gov (United States)

    Larson, Kelsey; Lee, Michelle; Davis, Janine; Guyuron, Bahman

    2011-11-01

    The purpose of this study was to identify factors that contribute to migraine headache surgery failure and success. A retrospective chart review was conducted of patients who underwent surgery for migraine headaches performed by the senior author (B.G.) and had at least 11 months of follow-up. The study population included three groups: migraine surgery success, improvement, and failure. Thirty-six unique data points were collected for each patient. A total of 169 patients met inclusion criteria. Of these, 66 patients comprised the migraine surgery success group (S, complete elimination of migraine headaches); 67 comprised the migraine surgery improvement group (I, >50 percent reduction in migraine frequency, intensity, or duration); and 36 comprised the migraine surgery failure group (F, I, p=0.02), migraine frequency (SI, p=0.003; S>F, p=0.04), history of head or neck injury (SI, p=0.02), increased intraoperative bleeding (SF, p=0.0006; I>F, p=0.0004), site II (S>F, p=0.015), single operative site (SI, p=0.05; S>F, p=0.04). Factors associated with migraine surgery failure include increased intraoperative bleeding and surgery on fewer trigger sites. Factors associated with migraine surgery success are older age of migraine onset, higher rate of visual symptoms versus improvement group, surgery at site I or II, and deactivating all four operative sites. Risk, III.

  8. Asymptotic behaviour of total times for jobs that must start over if a failure occurs

    DEFF Research Database (Denmark)

    Asmussen, Søren; Fiorini, Pierre; Lipsky, Lester

    2008-01-01

    Many processes must complete in the presence of failures. Different systems respond to task failure in different ways. The system may resume a failed task from the failure point (or a saved checkpoint shortly before the failure point), it may give up on the task and select a replacement task from...

  9. Asymptotic behavior of total times For jobs that must start over if a failure occurs

    DEFF Research Database (Denmark)

    Asmussen, Søren; Fiorini, Pierre; Lipsky, Lester

    Many processes must complete in the presence of failures. Different systems respond to task failure in different ways. The system may resume a failed task from the failure point (or a saved checkpoint shortly before the failure point), it may give up on the task and select a replacement task from...

  10. Heart failure - surgeries and devices

    Science.gov (United States)

    CHF - surgery; Congestive heart failure - surgery; Cardiomyopathy - surgery; HF - surgery; Intra-aortic balloon pumps - heart failure; IABP - heart failure; Catheter based assist devices - heart failure

  11. Modification and Validation of the Triglyceride-to-HDL Cholesterol Ratio as a Surrogate of Insulin Sensitivity in White Juveniles and Adults without Diabetes Mellitus: The Single Point Insulin Sensitivity Estimator (SPISE).

    Science.gov (United States)

    Paulmichl, Katharina; Hatunic, Mensud; Højlund, Kurt; Jotic, Aleksandra; Krebs, Michael; Mitrakou, Asimina; Porcellati, Francesca; Tura, Andrea; Bergsten, Peter; Forslund, Anders; Manell, Hannes; Widhalm, Kurt; Weghuber, Daniel; Anderwald, Christian-Heinz

    2016-09-01

    The triglyceride-to-HDL cholesterol (TG/HDL-C) ratio was introduced as a tool to estimate insulin resistance, because circulating lipid measurements are available in routine settings. Insulin, C-peptide, and free fatty acids are components of other insulin-sensitivity indices but their measurement is expensive. Easier and more affordable tools are of interest for both pediatric and adult patients. Study participants from the Relationship Between Insulin Sensitivity and Cardiovascular Disease [43.9 (8.3) years, n = 1260] as well as the Beta-Cell Function in Juvenile Diabetes and Obesity study cohorts [15 (1.9) years, n = 29] underwent oral-glucose-tolerance tests and euglycemic clamp tests for estimation of whole-body insulin sensitivity and calculation of insulin sensitivity indices. To refine the TG/HDL ratio, mathematical modeling was applied including body mass index (BMI), fasting TG, and HDL cholesterol and compared to the clamp-derived M-value as an estimate of insulin sensitivity. Each modeling result was scored by identifying insulin resistance and correlation coefficient. The Single Point Insulin Sensitivity Estimator (SPISE) was compared to traditional insulin sensitivity indices using area under the ROC curve (aROC) analysis and χ(2) test. The novel formula for SPISE was computed as follows: SPISE = 600 × HDL-C(0.185)/(TG(0.2) × BMI(1.338)), with fasting HDL-C (mg/dL), fasting TG concentrations (mg/dL), and BMI (kg/m(2)). A cutoff value of 6.61 corresponds to an M-value smaller than 4.7 mg · kg(-1) · min(-1) (aROC, M:0.797). SPISE showed a significantly better aROC than the TG/HDL-C ratio. SPISE aROC was comparable to the Matsuda ISI (insulin sensitivity index) and equal to the QUICKI (quantitative insulin sensitivity check index) and HOMA-IR (homeostasis model assessment-insulin resistance) when calculated with M-values. The SPISE seems well suited to surrogate whole-body insulin sensitivity from inexpensive fasting single-point blood draw and BMI

  12. Procalcitonin for selecting the antibiotic regimen in outpatients with low-risk community-acquired pneumonia using a rapid point-of-care testing: A single-arm clinical trial.

    Directory of Open Access Journals (Sweden)

    Mar Masiá

    Full Text Available We aimed to assess the role of procalcitonin (PCT to guide the initial selection of the antibiotic regimen for low-risk community-acquired pneumonia (CAP.A single-arm clinical trial was conducted including outpatients with CAP and Pneumonia Severity Index risk classes I-II. Antimicrobial selection was based on the results of PCT measured with a rapid point-of-care testing. According to serum PCT levels, patients were assigned to two treatment strategies: oral azithromycin if PCT was <0.5 ng/ml, or levofloxacin if levels were ≥0.5 ng/ml. Primary outcome was clinical cure rate. Short-term and long-term outcomes were assessed. Results were compared with those of a historical standard-of-care control-group treated in our centre.Of 253 subjects included, 216 (85.4% were assigned to azithromycin. Pneumococcal infection was diagnosed in 26 (12% and 21 (56.8% patients allocated to azithromycin and levofloxacin groups, respectively. No patients in the azithromycin group developed bacteraemia. Atypical organisms were more common in patients given azithromycin (18.5% vs 8.1%, respectively. The majority (93% of patients with atypical pneumonia had low PCT levels. Clinical cure rates were 95.8% in the azithromycin group, 94.6% in the levofloxacin group, and 94.4% in the historical control group. No 30-day mortality or recurrences were observed, and the 3-year rates of recurrence and mortality were very low in both groups. Adverse events occurrence was also infrequent.A PCT-guided strategy with a rapid point-of-care testing safely allowed selecting empirical narrow-spectrum antibiotics in outpatients with CAP.The study is registered with ClinicalTrials.gov, number NCT02600806.

  13. EVALUATION OF LIVER FAILURE STAGE IN CHILDREN

    Directory of Open Access Journals (Sweden)

    G. V. Volynets

    2013-01-01

    Full Text Available Aim: to develop a system of evaluation of liver failure stage in children based on the International classification of functioning, disability and health (ICF. Patients and methods: based on the retrospective analysis of 14 biochemical markers, characterizing hepatic role in proteins, lipids and carbohydrates metabolism, of 115 children without liver diseases, 15 children who died of liver failure and 220 patients with various hepatic disorders, being followed-up in the SCCH of RAMS, a score system of evaluation of liver failure stage in children as an additional diagnostic tool was developed. Each of the biochemical markers was assessed according to the 5-point rating scale in dependence of its changes intensity. Results: the sum of points was considered to be a criterion of liver failure stage. According to the ICF recommendations, decrease of points on 0–4% (54–56 points corresponds with absence of liver failure; 5–24% (43–53 points — as mild dysfunction, 25–49% (29–42 points — as moderate; 50-95% (3–28 points — as severe; and 96–100% (0-2 points — as absolute failure. Conclusions: score system of evaluation of liver failure stage can be applied at any step of diagnostics and treatment of children of any age, due to independence of the used markers from the age. It can be used in assessment of the severity of disorder in dynamics, in determination of the prognosis and as criterion of indications to liver transplantation, as well as during medico-social examination.

  14. Advanced Heart Failure

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Advanced Heart Failure Updated:May 9,2017 When heart failure (HF) ... Making This content was last reviewed May 2017. Heart Failure • Home • About Heart Failure • Causes and Risks for ...

  15. Angiotensin inhibition in heart failure

    Directory of Open Access Journals (Sweden)

    John JV Mcmurray

    2004-03-01

    Full Text Available Survival in patients with heart failure remains very poor, and is worse than that for most common cancers, including bowel cancer in men and breast cancer in women. The renin-angiotensin-aldosterone system (RAAS is not completely blocked by angiotensin-converting enzyme (ACE inhibition. Blockade of the RAAS at the AT1-receptor has the theoretical benefit of more effective blockade of the actions of angiotensin II. ACE inhibitors (ACE-Is prevent the breakdown of bradykinin: this has been blamed for some of the unwanted effects of ACE-Is although bradykinin may have advantageous effects in heart failure. Consequently, ACE-Is and ARBs might be complementary or even additive treatments; recent trials have tested these hypotheses. The Candesartan in Heart failure Assessment of Reduction in Mortality and morbidity (CHARM programme compared the angiotensin receptor blocker (ARB candesartan (target dose 32 mg once daily to placebo in three distinct but complementary populations of patients with symptomatic heart failure. These were: patients with reduced left ventricular ejection fraction (LVEF who were ACE-I-intolerant (CHARM-Alternative; patients with reduced LVEF who were being treated with ACE-Is (CHARM-Added; and patients with preserved left ventricular systolic function (CHARM-Preserved. There were substantial and statistically significant reductions in the primary composite end point (risk of cardiovascular death or hospital admission for heart failure in CHARM-Alternative. This was also the case in CHARM-Added, supporting and extending the findings of Val-HeFT. In CHARM-Preserved, the effect of candesartan on the primary end point did not reach conventional statistical significance though hospital admission for heart failure was reduced significantly with candesartan. In the CHARM-Overall programme there was a statistically borderline reduction in all-cause mortality with a clear reduction in cardiovascular mortality. All-cause mortality was

  16. Angiotensin inhibition in heart failure

    Directory of Open Access Journals (Sweden)

    John JV McMurray

    2004-03-01

    Full Text Available Survival in patients with heart failure remains very poor, and is worse than that for most common cancers, including bowel cancer in men and breast cancer in women. The renin-angiotensin-aldosterone system (RAAS is not completely blocked by angiotensin-converting enzyme (ACE inhibition. Blockade of the RAAS at the AT1-receptor has the theoretical benefit of more effective blockade of the actions of angiotensin II. ACE inhibitors (ACE-Is prevent the breakdown of bradykinin: this has been blamed for some of the unwanted effects of ACE-Is although bradykinin may have advantageous effects in heart failure. Consequently, ACE-Is and ARBs might be complementary or even additive treatments; recent trials have tested these hypotheses.The Candesartan in Heart failure Assessment of Reduction in Mortality and morbidity (CHARM programme compared the angiotensin receptor blocker (ARB candesartan (target dose 32 mg once daily to placebo in three distinct but complementary populations of patients with symptomatic heart failure. These were: patients with reduced left ventricular ejection fraction (LVEF who were ACE-I-intolerant (CHARM-Alternative; patients with reduced LVEF who were being treated with ACE-Is (CHARM-Added; and patients with preserved left ventricular systolic function (CHARM-Preserved.There were substantial and statistically significant reductions in the primary composite end point (risk of cardiovascular death or hospital admission for heart failure in CHARM-Alternative. This was also the case in CHARM-Added, supporting and extending the findings of Val-HeFT. In CHARM-Preserved, the effect of candesartan on the primary end point did not reach conventional statistical significance though hospital admission for heart failure was reduced significantly with candesartan. In the CHARM-Overall programme there was a statistically borderline reduction in all-cause mortality with a clear reduction in cardiovascular mortality. All-cause mortality was

  17. Successive failure, repeat entrepreneurship and no learning: A case study

    Directory of Open Access Journals (Sweden)

    Marius Pretorius

    2011-10-01

    Full Text Available Orientation: Current theories of repeat entrepreneurship provide little explanation for the effect of failure as a ‘trigger’ for creating successive ventures or learning from repeated failures. Research purpose: This study attempts to establish the role of previous failures on the ventures that follow them and to determine the process of learning from successive failures. Motivation for the study: Successive failures offer potentially valuable insights into the relationship between failures on the ventures that follow and the process of learning from failure. Research design, approach and method: The researchers investigated a single case study of one entrepreneur’s successive failures over 20 years. Main findings: Although the causes varied, all the failures had fundamental similarities. This suggested that the entrepreneur had not learnt from them. The previous failures did not trigger the subsequent ventures. Instead, they played a role in causing the failures. Learning from failure does not happen immediately but requires deliberate reflection. Deliberate reflection is a prerequisite for learning from failure as the entrepreneur repeated similar mistakes time after time until he reflected on each failure. Practical/managerial implications: It confirms that failure is a part of entrepreneurial endeavours. However, learning from it requires deliberate reflection. Failure does not ‘trigger’ the next venture and educators should note this. Contribution/value-add: Knowing the effect of failure on consecutive ventures may help us to understand the development of prototypes (mental frameworks and expand the theory about entrepreneurial prototype categories.

  18. Immune mediated liver failure

    OpenAIRE

    Wang, Xiaojing; Ning, Qin

    2014-01-01

    Liver failure is a clinical syndrome of various etiologies, manifesting as jaundice, encephalopathy, coagulopathy and circulatory dysfunction, which result in subsequent multiorgan failure. Clinically, liver failure is classified into four categories: acute, subacute, acute-on-chronic and chronic liver failure. Massive hepatocyte death is considered to be the core event in the development of liver failure, which occurs when the extent of hepatocyte death is beyond the liver regenerative capac...

  19. Failure to thrive: an update.

    Science.gov (United States)

    Cole, Sarah Z; Lanham, Jason S

    2011-04-01

    Failure to thrive in childhood is a state of undernutrition due to inadequate caloric intake, inadequate caloric absorption, or excessive caloric expenditure. In the United States, it is seen in 5 to 10 percent of children in primary care settings. Although failure to thrive is often defined as a weight for age that falls below the 5th percentile on multiple occasions or weight deceleration that crosses two major percentile lines on a growth chart, use of any single indicator has a low positive predictive value. Most cases of failure to thrive involve inadequate caloric intake caused by behavioral or psychosocial issues. The most important part of the outpatient evaluation is obtaining an accurate account of a child's eating habits and caloric intake. Routine laboratory testing rarely identifies a cause and is not generally recommended. Reasons to hospitalize a child for further evaluation include failure of outpatient management, suspicion of abuse or neglect, or severe psychosocial impairment of the caregiver. A multidisciplinary approach to treatment, including home nursing visits and nutritional counseling, has been shown to improve weight gain, parent-child relationships, and cognitive development. The long-term effects of failure to thrive on cognitive development and future academic performance are unclear.

  20. Single gaze gestures

    DEFF Research Database (Denmark)

    Møllenbach, Emilie; Lilholm, Martin; Gail, Alastair

    2010-01-01

    This paper examines gaze gestures and their applicability as a generic selection method for gaze-only controlled interfaces. The method explored here is the Single Gaze Gesture (SGG), i.e. gestures consisting of a single point-to-point eye movement. Horizontal and vertical, long and short SGGs were...

  1. Microscopic observations during longitudinal compression loading of single pulp fibers

    Science.gov (United States)

    Irving B. Sachs

    1986-01-01

    Paperboard components (linerboard adn corrugating medium) fail in edgewise compression because of failure of single fibers, as well as fiber-to-fiber bonds. While fiber-to-fiber-bond failure has been studied extensively, little is known about the longitudinal compression failure of a single fiber. In this study, surface alterations on single loblolly pine kraft pulp...

  2. Heart failure - home monitoring

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000113.htm Heart failure - home monitoring To use the sharing features on this page, please enable JavaScript. Heart failure is a condition in which the heart is ...

  3. Real System Failures

    Data.gov (United States)

    National Aeronautics and Space Administration — This resource area contains descriptions of actual electronic systems failure scenarios with an emphasis on the diversity of failure modes and effects that can...

  4. Acute liver failure

    DEFF Research Database (Denmark)

    Larsen, Fin Stolze; Bjerring, Peter Nissen

    2011-01-01

    Acute liver failure (ALF) results in a multitude of serious complications that often lead to multi-organ failure. This brief review focuses on the pathophysiological processes in ALF and how to manage these.......Acute liver failure (ALF) results in a multitude of serious complications that often lead to multi-organ failure. This brief review focuses on the pathophysiological processes in ALF and how to manage these....

  5. Potentially damaging failure modes of high- and medium-voltage electrical equipment

    International Nuclear Information System (INIS)

    Hoy, H.C.

    1983-07-01

    The electrical equipment failures of both nuclear and nonnuclear public utilities were reviewed. Those failures that could pose an additional problem to surrounding and connected equipment were defined. The literature was searched; utilities, repair shops, and large electrical equipment users were contacted for failure information. The data were reviewed in detail, and failure modes were determined. Sample cascade failures are discussed. The failure rate of electrical equipment in utilities is historically quite low. Nuclear plants record too few failures to be statistically valid, but failures that have been recorded show that good design usually restricts the failure to a single piece of equipment

  6. In Support of Failure

    Science.gov (United States)

    Carr, Allison

    2013-01-01

    In this essay, I propose a concerted effort to begin devising a theory and pedagogy of failure. I review the discourse of failure in Western culture as well as in composition pedagogy, ultimately suggesting that failure is not simply a judgement or indication of rank but is a relational, affect-bearing concept with tremendous relevance to…

  7. Acute Liver Failure

    Science.gov (United States)

    ... begins in or spreads to your liver can cause your liver to fail. Shock. Overwhelming infection (sepsis) and shock can severely impair blood flow to the liver, causing liver failure. Many cases of acute liver failure have no apparent ... liver failure often causes complications, including: ...

  8. Prediction of failure enthalpy and reliability of irradiated fuel rod under reactivity-initiated accidents by means of statistical approach

    International Nuclear Information System (INIS)

    Nam, Cheol; Choi, Byeong Kwon; Jeong, Yong Hwan; Jung, Youn Ho

    2001-01-01

    During the last decade, the failure behavior of high-burnup fuel rods under RIA has been an extensive concern since observations of fuel rod failures at low enthalpy. Of great importance is placed on failure prediction of fuel rod in the point of licensing criteria and safety in extending burnup achievement. To address the issue, a statistics-based methodology is introduced to predict failure probability of irradiated fuel rods. Based on RIA simulation results in literature, a failure enthalpy correlation for irradiated fuel rod is constructed as a function of oxide thickness, fuel burnup, and pulse width. From the failure enthalpy correlation, a single damage parameter, equivalent enthalpy, is defined to reflect the effects of the three primary factors as well as peak fuel enthalpy. Moreover, the failure distribution function with equivalent enthalpy is derived, applying a two-parameter Weibull statistical model. Using these equations, the sensitivity analysis is carried out to estimate the effects of burnup, corrosion, peak fuel enthalpy, pulse width and cladding materials used

  9. Conversion of Human Steroid 5[beta]-Reductase (AKR1D1) into 3[beta]-Hydroxysteroid Dehydrogenase by Single Point Mutation E120H: Example of Perfect Enzyme Engineering

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Mo; Drury, Jason E.; Christianson, David W.; Penning, Trevor M. (UPENN)

    2012-10-10

    Human aldo-keto reductase 1D1 (AKR1D1) and AKR1C enzymes are essential for bile acid biosynthesis and steroid hormone metabolism. AKR1D1 catalyzes the 5{beta}-reduction of {Delta}{sup 4}-3-ketosteroids, whereas AKR1C enzymes are hydroxysteroid dehydrogenases (HSDs). These enzymes share high sequence identity and catalyze 4-pro-(R)-hydride transfer from NADPH to an electrophilic carbon but differ in that one residue in the conserved AKR catalytic tetrad, His120 (AKR1D1 numbering), is substituted by a glutamate in AKR1D1. We find that the AKR1D1 E120H mutant abolishes 5{beta}-reductase activity and introduces HSD activity. However, the E120H mutant unexpectedly favors dihydrosteroids with the 5{alpha}-configuration and, unlike most of the AKR1C enzymes, shows a dominant stereochemical preference to act as a 3{beta}-HSD as opposed to a 3{alpha}-HSD. The catalytic efficiency achieved for 3{beta}-HSD activity is higher than that observed for any AKR to date. High resolution crystal structures of the E120H mutant in complex with epiandrosterone, 5{beta}-dihydrotestosterone, and {Delta}{sup 4}-androstene-3,17-dione elucidated the structural basis for this functional change. The glutamate-histidine substitution prevents a 3-ketosteroid from penetrating the active site so that hydride transfer is directed toward the C3 carbonyl group rather than the {Delta}{sup 4}-double bond and confers 3{beta}-HSD activity on the 5{beta}-reductase. Structures indicate that stereospecificity of HSD activity is achieved because the steroid flips over to present its {alpha}-face to the A-face of NADPH. This is in contrast to the AKR1C enzymes, which can invert stereochemistry when the steroid swings across the binding pocket. These studies show how a single point mutation in AKR1D1 can introduce HSD activity with unexpected configurational and stereochemical preference.

  10. Heart failure in children - overview

    Science.gov (United States)

    Congestive heart failure - children; Cor pulmonale - children; Cardiomyopathy - children; CHF - children; Congenital heart defect - heart failure in children; Cyanotic heart disease - heart failure in children; Birth ...

  11. Out-of-plane integration of a multimode optical fiber for single particle/cell detection at multiple points on a microfluidic device with applications to particle/cell counting, velocimetry, size discrimination and the analysis of single cell lysate injections.

    Science.gov (United States)

    Sadeghi, Jalal; Patabadige, Damith E W; Culbertson, Anne H; Latifi, Hamid; Culbertson, Christopher T

    2016-12-20

    In this paper a single particle/cell-tracking microfluidic device that integrates an out-of-plane multimode optical fiber (OP-MMF) is reported. This OP-MMF is used to generate three excitation light-lines and three detection spots using only one excitation source and one detector. It takes advantage of an optical tunneling mode to create two excitation lines in a microfluidic channel emanating from a single fiber end. This method was used to accurately count particles/cells and perform velocity measurements and size discrimination. The velocity and size distributions of 5, 7, and 10 μm fluorescently labeled polystyrene beads were determined using the OP-MMF. Additionally, this method was used to analyze cell lysates with the third excitation line in the separation channel. The OP-MMF setup accurately detected an intact cell twice ∼2 mm prior to lysis, determined its velocity, and detected the injected cell lysate 3 mm downstream of the injection point in the separation channel. Using this setup, the velocity of cells entering the lysis intersection and the absolute migration times of fluorescently labeled analytes injected into the separation channel were determined in an automated fashion. This method enabled us to determine a lysing/injection efficiency coefficient (K) using signals from the injected lysate signal and from the intact cell before lysing. K provided a reliable measurement of the amount of cell lysate that was injected into the separation channel. The approach reported here could be used in the future to track particles, cells or droplets in a variety of existing microfluidic devices without the need for multiplexed masks, layers, bulky optical elements or complex optical designs.

  12. Flexural fatigue failures and lives of Eco-Core sandwich beams

    International Nuclear Information System (INIS)

    Hossain, Mohammad Mynul; Shivakumar, Kunigal

    2014-01-01

    Highlights: • Eco-Core sandwich beam is flexural fatigue tested to study its fatigue response. • The core showed three failure types: damage onset, progression and final failure. • These failures were found to be represented by 1%, 5% and 7% change in compliance. • The fatigue stress-life (S–N) relationship follows a power low, σ max /σ ct = A o N α . • The fatigue failure was by multiple vertical cracks followed by 45° shear failure. - Abstract: Eco-Core is a class of syntactic foam made from small volume of high char yield binder and large volume of a class of flyash for fire resistance application. Very little or no flexural fatigue data of this class of core material is reported in the open literature. This paper presents a flexural fatigue response of Eco-Core in a glass/vinyl ester composite face sheet sandwich beam. A four-point loaded flexural test specimen was designed and tested in static and fatigue loadings to cause tension failure in the core. The fatigue test was conducted at maximum cyclic stress (σ max ) ranged from 0.7σ ct to 0.9σ ct , where σ ct is the static flexural strength of the core. The sinusoidal loading frequency of 2 Hz with the stress ratio of 0.1 was used. Flexural fatigue failure modes of Eco-Core sandwich beam were classified: damage onset (single tension crack), damage progression (multiple tension cracks) and ultimate failure (a combination of tension and shear). These failures were characterized by 1%, 5% and 7% changes in compliance that corresponds to N 1% , N 5% and N 7% lives. The fatigue stress-life (S–N) relationship was found to follow the well-known power law equation, σ max /σ ct = A o N α . The constants A o and α were established for all three types of failures. The endurance limit was established based on 1 million cycles limit and it was found to be 0.65σ ct , 0.70σ ct and 0.71σ ct , respectively for the three modes of failure. Flexural fatigue and static failure modes of Eco-Core sandwich

  13. Analysis of instrumentation failures after three column osteotomies of the spine.

    Science.gov (United States)

    Kavadi, Niranjan; Tallarico, Richard A; Lavelle, William F

    2017-01-01

    Correction of fixed spinal imbalance in a sagittal and/or coronal plane frequently needs a tricolumnar wedge resection when the deformity is rigid. Complications associated with deformity correction surgery are pseudoarthrosis and implant failure located along the construct. The purposes of this study were to assess comparative rates of pseudoarthrosis (implant failure) at weaker points along lumbosacral junction and level of osteotomy, estimate overall incidence of implant failure, and comparatively analyze failures at different points along the construct. This was an IRB approved, single center study retrospective analysis. Twenty-six patients who underwent three column osteotomies were grouped according to procedure: pedicle subtraction osteotomy (PSO, ( n  = 18)); vertebral column resection (VCR, ( n  = 4)); hemivertebra excision (HE, ( n  = 2)); and extracavitary corpectomy (EC, ( n  = 2)). Follow-up data is presented on all of the study patients. Number of levels of fusion, anchors, percent saturation of fixation levels, type of bone graft and graft substitutes, and rod material and diameter were recorded. Radiographical data was reviewed preoperatively and postoperatively at 2 weeks and 3, 6, and 12 months and annually to determine sagittal and coronal balance, lumbopelvic parameters, presence or absence of interbody structural support, laterality or rod failure, and time to implant failure. Twenty-seven percent (7/26) patients demonstrated rod breakage either unilaterally ( N  = 2) or bilaterally ( N  = 5) during follow-up. Seventy-one percent had increasing back pain or worsening sagittal balance, while remaining failures found incidentally. No failures in children were seen. Tricolumnar osteotomy by posterior approach is a valuable tool. Rod failures found approximately 1 year from surgery, with 86% located at level of osteotomy and 14% at lumbosacral junction. Possible reasons are increased stress in the rod at this point and

  14. Intestinal Failure (Short Bowel Syndrome)

    Science.gov (United States)

    Intestinal Failure (Short Bowel Syndrome) What is intestinal failure? Intestinal failure occurs when a significant portion of the small ... intestine does. Who is at risk for intestinal failure? N Babies (usually premature) who have had surgery ...

  15. Change of BNP between admission and discharge after ST-elevation myocardial infarction (Killip I) improves risk prediction of heart failure, death, and recurrent myocardial infarction compared to single isolated measurement in addition to the GRACE score.

    Science.gov (United States)

    Carvalho, Luiz Sergio F; Bogniotti, Lauro Afonso C; de Almeida, Osorio Luis Rangel; E Silva, Jose C Quinaglia; Nadruz, Wilson; Coelho, Otavio Rizzi; Sposito, Andrei C

    2018-01-01

    In ST-elevation myocardial infarction, 7-15% of patients admitted as Killip I will develop symptomatic heart failure or decreased ejection fraction. However, available clinical scores do not predict the risk of severe outcomes well, such as heart failure, recurrent myocardial infarction, and sudden death in these Killip I individuals. Therefore, we evaluated whether one vs two measurements of BNP would improve prediction of adverse outcomes in addition to the GRACE score in ST-elevation myocardial infarction/Killip I individuals. Consecutive patients with ST-elevation myocardial infarction/Killip I ( n=167) were admitted and followed for 12 months. The GRACE score was calculated and plasma BNP levels were obtained in the first 12 h after symptom onset (D1) and at the fifth day (D5). Fifteen percent of patients admitted as Killip I developed symptomatic heart failure and/or decreased ejection fraction in 12 months. The risk of developing symptomatic heart failure or ejection fraction <40% at 30 days was increased by 8.7-fold (95% confidence interval: 1.10-662, p=0.046) per each 100 pg/dl increase in BNP-change. Both in unadjusted and adjusted Cox-regressions, BNP-change as a continuous variable was associated with incident sudden death/myocardial infarction at 30 days (odds ratio 1.032 per each increase of 10 pg/dl, 95% confidence interval: 1.013-1.052, p<0.001), but BNP-D1 was not. The GRACE score alone showed a moderate C-statistic=0.709 ( p=0.029), but adding BNP-change improved risk discrimination (C-statistic=0.831, p=0.001). Net reclassification confirmed a significant improvement in individual risk prediction by 33.4% (95% confidence interval: 8-61%, p=0.034). However, GRACE +BNP-D1 did not improve risk reclassification at 30 days compared to GRACE ( p=0.8). At 12 months, BNP-change was strongly associated with incident sudden death/myocardial infarction, but not BNP-D1. Only BNP-change following myocardial infarction was associated with poorer short- and

  16. Definition of containment failure

    International Nuclear Information System (INIS)

    Cybulskis, P.

    1982-01-01

    Core meltdown accidents of the types considered in probabilistic risk assessments (PRA's) have been predicted to lead to pressures that will challenge the integrity of containment structures. Review of a number of PRA's indicates considerable variation in the predicted probability of containment failure as a function of pressure. Since the results of PRA's are sensitive to the prediction of the occurrence and the timing of containment failure, better understanding of realistic containment capabilities and a more consistent approach to the definition of containment failure pressures are required. Additionally, since the size and location of the failure can also significantly influence the prediction of reactor accident risk, further understanding of likely failure modes is required. The thresholds and modes of containment failure may not be independent

  17. Equations for arithmetic pointed tori

    NARCIS (Netherlands)

    Sijsling, J.R.

    2010-01-01

    In 1983, Kisao Takeuchi enumerated all 71 arithmetic (1;e)-groups. This is a special set of discrete subgroups of SL(2,R) of finite covolume and signature (1;e). The corresponding quotients of the upper half plane (called (1;e)-curves) have genus equal to 1 and a single elliptic point of order e.

  18. Address Points - Allegheny County Address Points 201601

    Data.gov (United States)

    NSGIC Education | GIS Inventory — This dataset contains Address Points in Allegheny County. The Address Points were created by GDR for the Allegheny County CAD project, October 2008. Data is updated...

  19. Access to Liver Transplantation in Different ABO-Blood Groups and "Exceptions Points" in a Model for End-Stage Liver Disease Allocation System: A Brazilian Single-Center Study.

    Science.gov (United States)

    Martino, R B; Waisberg, D R; Dias, A P M; Inoue, V B S; Arantes, R M; Haddad, L B P; Rocha-Santos, V; Pinheiro, R S N; Nacif, L S; D'Albuquerque, L A C

    2018-04-01

    In the Model for End-Stage Liver Disease (MELD) system, patients with "MELD exceptions" points may have unfair privilege in the competition for liver grafts. Furthermore, organ distribution following identical ABO blood types may also result in unjust organ allocation. The aim of this study was to investigate access to liver transplantation in a tertiary Brazilian center, regarding "MELD exceptions" situations and among ABO-blood groups. A total of 465 adult patients on the liver waitlist from August 2015 to August 2016 were followed up until August 2017. Patients were divided into groups according to ABO-blood type and presence of "exceptions points." No differences in outcomes were observed among ABO-blood groups. However, patients from B and AB blood types spent less time on the list than patients from A and O groups (median, 46, 176, 415, and 401 days, respectively; P = .03). "Exceptions points" were granted for 141 patients (30.1%), hepatocellular carcinoma being the most common reason (52.4%). Patients with "exceptions points" showed higher transplantation rate, lower mortality on the list, and lower delta-MELD than non-exceptions patients (56.7% vs 19.1% [P blood types, despite shorter time on the waitlist for AB and B groups. The current MELD exception system provides advantages for candidates with "exception points," resulting in superior outcomes compared with those without exceptions. Copyright © 2018 Elsevier Inc. All rights reserved.

  20. Relative Critical Points

    Directory of Open Access Journals (Sweden)

    Debra Lewis

    2013-05-01

    Full Text Available Relative equilibria of Lagrangian and Hamiltonian systems with symmetry are critical points of appropriate scalar functions parametrized by the Lie algebra (or its dual of the symmetry group. Setting aside the structures – symplectic, Poisson, or variational – generating dynamical systems from such functions highlights the common features of their construction and analysis, and supports the construction of analogous functions in non-Hamiltonian settings. If the symmetry group is nonabelian, the functions are invariant only with respect to the isotropy subgroup of the given parameter value. Replacing the parametrized family of functions with a single function on the product manifold and extending the action using the (coadjoint action on the algebra or its dual yields a fully invariant function. An invariant map can be used to reverse the usual perspective: rather than selecting a parametrized family of functions and finding their critical points, conditions under which functions will be critical on specific orbits, typically distinguished by isotropy class, can be derived. This strategy is illustrated using several well-known mechanical systems – the Lagrange top, the double spherical pendulum, the free rigid body, and the Riemann ellipsoids – and generalizations of these systems.

  1. Tipping point leadership.

    Science.gov (United States)

    Kim, W Chan; Mauborgne, Renée

    2003-04-01

    When William Bratton was appointed police commissioner of New York City in 1994, turf wars over jurisdiction and funding were rife and crime was out of control. Yet in less than two years, and without an increase in his budget, Bratton turned New York into the safest large city in the nation. And the NYPD was only the latest of five law-enforcement agencies Bratton had turned around. In each case, he succeeded in record time despite limited resources, a demotivated staff, opposition from powerful vested interests, and an organization wedded to the status quo. Bratton's turnarounds demonstrate what the authors call tipping point leadership. The theory of tipping points hinges on the insight that in any organization, fundamental changes can occur quickly when the beliefs and energies of a critical mass of people create an epidemic movement toward an idea. Bratton begins by overcoming the cognitive hurdles that block organizations from recognizing the need for change. He does this by putting managers face-to-face with operational problems. Next, he manages around limitations on funds, staff, or equipment by concentrating resources on the areas that are most in need of change and that have the biggest payoffs. He meanwhile solves the motivation problem by singling out key influencers--people with disproportionate power due to their connections or persuasive abilities. Finally, he closes off resistance from powerful opponents. Not every CEO has the personality to be a Bill Bratton, but his successes are due to much more than his personality. He relies on a remarkably consistent method that any manager looking to turn around an organization can use to overcome the forces of inertia and reach the tipping point.

  2. A Failure Locus for Hydrogen Assisted Failure

    DEFF Research Database (Denmark)

    Fuentes-Alonso, Sandra; Harris, Zach D.; Burns, James T.

    2017-01-01

    important insight into the failure process, enabling to identify critical values of hydrogen concentration and remote stresses that trigger cracking. The work builds upon previous works by the authors and brings important insight into the technologically important problem of hydrogen assisted cracking....

  3. Bone Marrow Failure Secondary to Cytokinesis Failure

    Science.gov (United States)

    2015-12-01

    SUPPLEMENTARY NOTES 14. ABSTRACT Fanconi anemia (FA) is a human genetic disease characterized by a progressive bone marrow failure and heightened...L. Tian, M. Kahkonen, J. Schwartzentruber, M. Kircher, G. University of Washington Centre for Mendelian , F.C. Consortium, J. Majewski, D.A. Dyment

  4. Failure Forecasting in Triaxially Stressed Sandstones

    Science.gov (United States)

    Crippen, A.; Bell, A. F.; Curtis, A.; Main, I. G.

    2017-12-01

    Precursory signals to fracturing events have been observed to follow power-law accelerations in spatial, temporal, and size distributions leading up to catastrophic failure. In previous studies this behavior was modeled using Voight's relation of a geophysical precursor in order to perform `hindcasts' by solving for failure onset time. However, performing this analysis in retrospect creates a bias, as we know an event happened, when it happened, and we can search data for precursors accordingly. We aim to remove this retrospective bias, thereby allowing us to make failure forecasts in real-time in a rock deformation laboratory. We triaxially compressed water-saturated 100 mm sandstone cores (Pc= 25MPa, Pp = 5MPa, σ = 1.0E-5 s-1) to the point of failure while monitoring strain rate, differential stress, AEs, and continuous waveform data. Here we compare the current `hindcast` methods on synthetic and our real laboratory data. We then apply these techniques to increasing fractions of the data sets to observe the evolution of the failure forecast time with precursory data. We discuss these results as well as our plan to mitigate false positives and minimize errors for real-time application. Real-time failure forecasting could revolutionize the field of hazard mitigation of brittle failure processes by allowing non-invasive monitoring of civil structures, volcanoes, and possibly fault zones.

  5. Parathyroid hormone secretion in chronic renal failure

    DEFF Research Database (Denmark)

    Madsen, J C; Rasmussen, A Q; Ladefoged, S D

    1996-01-01

    The aim of study was to introduce and evaluate a method for quantifying the parathyroid hormone (PTH) secretion during hemodialysis in secondary hyperparathyroidism due to end-stage renal failure. We developed a method suitable for inducing sequential hypocalcemia and hypercalcemia during....../ionized calcium curves were constructed, and a mean calcium set-point of 1.16 mmol/liter was estimated compared to the normal mean of about 1.13 mmol/liter. In conclusion, we demonstrate that it is important to use a standardized method to evaluate parathyroid hormone dynamics in chronic renal failure. By the use...... of a standardized method we show that the calcium set-point is normal or slightly elevated, indicating normal parathyroid reactivity to calcium in chronic renal failure....

  6. Detecting failure of climate predictions

    Science.gov (United States)

    Runge, Michael C.; Stroeve, Julienne C.; Barrett, Andrew P.; McDonald-Madden, Eve

    2016-01-01

    The practical consequences of climate change challenge society to formulate responses that are more suited to achieving long-term objectives, even if those responses have to be made in the face of uncertainty1, 2. Such a decision-analytic focus uses the products of climate science as probabilistic predictions about the effects of management policies3. Here we present methods to detect when climate predictions are failing to capture the system dynamics. For a single model, we measure goodness of fit based on the empirical distribution function, and define failure when the distribution of observed values significantly diverges from the modelled distribution. For a set of models, the same statistic can be used to provide relative weights for the individual models, and we define failure when there is no linear weighting of the ensemble models that produces a satisfactory match to the observations. Early detection of failure of a set of predictions is important for improving model predictions and the decisions based on them. We show that these methods would have detected a range shift in northern pintail 20 years before it was actually discovered, and are increasingly giving more weight to those climate models that forecast a September ice-free Arctic by 2055.

  7. Regulatory experience with fuel failures in Switzerland

    International Nuclear Information System (INIS)

    Adam, L.

    2015-01-01

    In this paper the main ENSI activities like: supervision of reactor and radiation safety and security; supervision of safety of transports of nuclear materials and assess the safety of proposed solutions for the geological disposal are listed. Recent events concerning the reactor core, common causes for fuel failures, findings during inspections and potential root cause for fuel failures are discussed. Management of fuel failures, started from reporting of the event – evaluation of the need of imminent action; identification of the fuel element if possible till evaluation by the plant and fuel vendor and allowance by ENSI for repair of the fuel element and definition of measures (short and long term) are also presented. The following Conclusions by ENSI about status of fuel failures are made: 1) Number of fuel failures was reduced regardless more economic operation in all plants; 2) Old PWR and BWR reactors achieved 15 to 29 years operation without leakers, but two minor fuel damage during fuel handling appeared; 3) Newer plants are not better in achieving operation without leakers than older plants; 4) Technical improvements at fuel elements parallel to changes in operation strategy and improvements in manufacturing quality but single effects difficult to judge. The issues about how to implement “Zero Failure Rates” in regulations and how to achieve “Zero Failure Rates” as well as some future measures by ENSI are discussed

  8. Dopamine in heart failure and critical care

    NARCIS (Netherlands)

    Smit, AJ

    Dopamine is widely used in critical care to prevent renal function loss. Nevertheless sufficient evidence is still lacking of reduction in end points like mortality or renal replacement therapy. Dopaminergic treatment in chronic heart failure (CHF) has provided an example of unexpected adverse

  9. Failure of Kak quantum key distribution protocol

    Indian Academy of Sciences (India)

    Kak's quantum key distribution (QKD) protocol provides not only the distribution but also the integrity of secret key simultaneously in quantum channel. Consequently the additional exchange of information, used to check whether an eavesdropper exists, is unnecessary. In this comment, we will point out the failure of Kak's ...

  10. Immune mediated liver failure.

    Science.gov (United States)

    Wang, Xiaojing; Ning, Qin

    2014-01-01

    Liver failure is a clinical syndrome of various etiologies, manifesting as jaundice, encephalopathy, coagulopathy and circulatory dysfunction, which result in subsequent multiorgan failure. Clinically, liver failure is classified into four categories: acute, subacute, acute-on-chronic and chronic liver failure. Massive hepatocyte death is considered to be the core event in the development of liver failure, which occurs when the extent of hepatocyte death is beyond the liver regenerative capacity. Direct damage and immune-mediated liver injury are two major factors involved in this process. Increasing evidence has suggested the essential role of immune-mediated liver injury in the pathogenesis of liver failure. Here, we review the evolved concepts concerning the mechanisms of immune-mediated liver injury in liver failure from human and animal studies. Both innate and adaptive immunity, especially the interaction of various immune cells and molecules as well as death receptor signaling system are discussed. In addition, we highlight the concept of "immune coagulation", which has been shown to be related to the disease progression and liver injury exacerbation in HBV related acute-on-chronic liver failure.

  11. Acute heart failure syndrome

    African Journals Online (AJOL)

    Heart failure can be defined as a clinical syndrome in which a structural or functional cardiac abnormality impairs the capacity of the ventricle to fill or eject enough blood for the requirements of the body. Acute heart failure syndrome represents a complex, heterogeneous set of clinical conditions, all with the common.

  12. Chronic heart failure

    African Journals Online (AJOL)

    associated with a reduction in morbidity and mortality.3. Clinical picture. The symptoms of heart failure are ... crepitations and a third heart sound gallop, are more predictive, but none of them are 100% diagnostic. Therefore ... some abnormality) in heart failure with reduced ejection fraction. A normal ECG should prompt an ...

  13. Success by Failure

    Science.gov (United States)

    Andrews, Benjamin D.

    2017-01-01

    By taking the step to talk openly about his failure, the author stumbled upon one of several important lessons that he learned from this experience. The author recognized that he did not have to pretend anymore. In this article, the author shares his story of developing a "growth mindset" to overcome his own failure and support his…

  14. Modeling Epidemic Network Failures

    DEFF Research Database (Denmark)

    Ruepp, Sarah Renée; Fagertun, Anna Manolova

    2013-01-01

    This paper presents the implementation of a failure propagation model for transport networks when multiple failures occur resulting in an epidemic. We model the Susceptible Infected Disabled (SID) epidemic model and validate it by comparing it to analytical solutions. Furthermore, we evaluate...... to evaluate multiple epidemic scenarios in various network types....

  15. First-line endoscopic treatment with over-the-scope clips significantly improves the primary failure and rebleeding rates in high-risk gastrointestinal bleeding: A single-center experience with 100 cases.

    Science.gov (United States)

    Richter-Schrag, Hans-Jürgen; Glatz, Torben; Walker, Christine; Fischer, Andreas; Thimme, Robert

    2016-11-07

    To evaluate rebleeding, primary failure (PF) and mortality of patients in whom over-the-scope clips (OTSCs) were used as first-line and second-line endoscopic treatment (FLET, SLET) of upper and lower gastrointestinal bleeding (UGIB, LGIB). A retrospective analysis of a prospectively collected database identified all patients with UGIB and LGIB in a tertiary endoscopic referral center of the University of Freiburg, Germany, from 04-2012 to 05-2016 ( n = 93) who underwent FLET and SLET with OTSCs. The complete Rockall risk scores were calculated from patients with UGIB. The scores were categorized as < or ≥ 7 and were compared with the original Rockall data. Differences between FLET and SLET were calculated. Univariate and multivariate analysis were performed to evaluate the factors that influenced rebleeding after OTSC placement. Primary hemostasis and clinical success of bleeding lesions (without rebleeding) was achieved in 88/100 (88%) and 78/100 (78%), respectively. PF was significantly lower when OTSCs were applied as FLET compared to SLET (4.9% vs 23%, P = 0.008). In multivariate analysis, patients who had OTSC placement as SLET had a significantly higher rebleeding risk compared to those who had FLET (OR 5.3; P = 0.008). Patients with Rockall risk scores ≥ 7 had a significantly higher in-hospital mortality compared to those with scores < 7 (35% vs 10%, P = 0.034). No significant differences were observed in patients with scores < or ≥ 7 in rebleeding and rebleeding-associated mortality. Our data show for the first time that FLET with OTSC might be the best predictor to successfully prevent rebleeding of gastrointestinal bleeding compared to SLET. The type of treatment determines the success of primary hemostasis or primary failure.

  16. Leverage points for sustainability transformation.

    Science.gov (United States)

    Abson, David J; Fischer, Joern; Leventon, Julia; Newig, Jens; Schomerus, Thomas; Vilsmaier, Ulli; von Wehrden, Henrik; Abernethy, Paivi; Ives, Christopher D; Jager, Nicolas W; Lang, Daniel J

    2017-02-01

    Despite substantial focus on sustainability issues in both science and politics, humanity remains on largely unsustainable development trajectories. Partly, this is due to the failure of sustainability science to engage with the root causes of unsustainability. Drawing on ideas by Donella Meadows, we argue that many sustainability interventions target highly tangible, but essentially weak, leverage points (i.e. using interventions that are easy, but have limited potential for transformational change). Thus, there is an urgent need to focus on less obvious but potentially far more powerful areas of intervention. We propose a research agenda inspired by systems thinking that focuses on transformational 'sustainability interventions', centred on three realms of leverage: reconnecting people to nature, restructuring institutions and rethinking how knowledge is created and used in pursuit of sustainability. The notion of leverage points has the potential to act as a boundary object for genuinely transformational sustainability science.

  17. Failure points in the PKI architecture / Точки отказа в PKI архитектуре / Tačke otkaza u PKI arhitekturi

    Directory of Open Access Journals (Sweden)

    Radomir I. Prodanović

    2017-07-01

    Full Text Available Over the last 20 years, the PKI architecture has found its vast application, especially in the fields which require the establishment of a security infrastructure. Given that the purpose of this architecture is to be used for achieving higher security standards, its smooth operation has to be one of the main requirements for its implementation. Its complexity is mirrored in the numerous implementations that the PKI has had so far. For all the reasons mentioned above, it is of great importance to consider potential failure points of such a structure. Due to the complexity of these structures, this paper will present only a basic review of such stress points, without providing details on specific applications and types of implementations. The significance of failure points will be explained by examining the common features of the PKI architectures and the occurrence of failure points in these structures, and where possible, an overview of suggestions for preventing such failures will be provided. / За последних двадцать лет, архитектура PKI стала широко применяться, особенно в областях, требующих создания инфраструктуры безопасности. Учитывая, что цель создания такой архитектуры заключается в обеспечении безопасности систем, главными задачами при внедрении архитектуры PKI являются бесперебойная работа и взаимодействие с другими компонентами комплектной структуры. Из вышеизложенного следует, что прогноз потенциальных точек отказа представляет собой исключительно важный фактор. В связи с ограничением объема

  18. Radiology of renal failure

    International Nuclear Information System (INIS)

    Griffiths, H.J.

    1990-01-01

    This book covers most aspects of imaging studies in patients with renal failure. The initial chapter provides basic information on contrast agents, intravenous urography, and imaging findings in the urinary tract disorders responsible for renal failure and in patients who have undergone transplantation. It illustrates common gastro-intestinal abnormalities seen on barium studies in patients with renal failure. It illustrates the cardiopulmonary complications of renal failure and offers advice for radiologic differentiation. It details different aspects of skeletal changes in renal failure, including a basic description of the pathophysiology of the changes; many excellent illustrations of classic bone changes, arthritis, avascular necrosis, and soft-tissue calcifications; and details of bone mineral analysis

  19. Theodicies as Failures of Recognition

    Directory of Open Access Journals (Sweden)

    Sari Kivistö

    2017-11-01

    Full Text Available This paper examines the ethical failure of theodicies by integrating the perspectives of philosophical argumentation and literary reading and analysis. The paper consists of two main parts. In the first part, we propose an ethical critique of metaphysical realism by analyzing its inability to recognize the perspectival plurality and diversity of suffering. As theodicies seek to explain how an omnipotent, omniscient, and absolutely benevolent God could allow the world to contain evil and suffering, it can be argued that metaphysical realism—i.e., the thesis that the world possesses its own fundamental structure independently of human perspectives of conceptualization and inquiry—is a problematic starting point of theodicism. We examine the failure of recognition of others’ suffering inherent in theodicies as a failure based on the search for an overall reductive and objectifying picture (a “God’s-Eye View” that is constitutive of metaphysical realism. The second part of the paper shows why we should include insights from imaginative literature in our attempts to understand the recognition failures of theodicies. Emphasizing the literary, philosophical, and theological relevance of various modern rewritings of the Book of Job, which has been a crucially important sub-text for many later literary works in which the protagonists render a particular kind of human experience—unmerited suffering—we turn more closely to some literary examples, such as Joseph Roth’s novels Hiob and Die Rebellion. The tensions that are created around the moral controversy of the experiences of injustice and suffering and the human and religious reasoning and justification of violence are examined. The ambiguous ending of Hiob that adds an apparently hopeful and almost fairytale-like redemption to the story plays a crucial role in the interpretation provided in the paper. By analyzing some literary examples and their relation to the literary Job tradition

  20. neutron-Induced Failures in semiconductor Devices

    Energy Technology Data Exchange (ETDEWEB)

    Wender, Stephen Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-13

    Single Event Effects are a very significant failure mode in modern semiconductor devices that may limit their reliability. Accelerated testing is important for semiconductor industry. Considerable more work is needed in this field to mitigate the problem. Mitigation of this problem will probably come from Physicists and Electrical Engineers working together

  1. Single-coil and dual-coil defibrillator leads and association with clinical outcomes in a complete Danish nationwide ICD cohort

    DEFF Research Database (Denmark)

    Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C

    2016-01-01

    BACKGROUND: The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. OBJECTIVE: The purpose of this study was to compare clinical...... outcomes in patients with single- and dual-coil leads. METHODS: All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end...... point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. RESULTS: Single-coil leads were associated with lower all-cause mortality...

  2. SOR-ring failure

    International Nuclear Information System (INIS)

    Kitamura, Hideo

    1981-01-01

    It was in the autumn of 1976 that the SOR-ring (synchrotron radiation storage ring) has commenced the regular operation. Since then, the period when the operation was interrupted due to the failures of SOR-ring itself is in total about 8 weeks. Failures and accidents have occurred most in the vacuum system. Those failure experiences are described on the vacuum, electromagnet, radio-frequency acceleration and beam transport systems with their interrupted periods. The eleven failures in the vacuum system have been reported, such as bellows breakage in a heating-evacuating period, leakage from the bellows of straight-through valves (made in U.S.A. and Japan), and leakage from the joint flange of the vacuum system. The longest interruption was 5 weeks due to the failure of a domestically manufactured straight-through valve. The failures of the electromagnet system involve the breakage in a cooling water system, short circuit of a winding in the Q magnet power transformer, blow of a fuse protecting the deflection magnet power source by the current less than the rating, and others. The failures of the RF acceleration system include the breakage of an output electronic tube the breakage of a cavity ceramic, RF voltage fluctuation due to the contact deterioration at a cavity electrode, and the failure of grid bias power source. It is necessary to select the highly reliable components for the vacuum system because the vacuum system failures require longer time for recovery, and very likely to induce secondary and tertiary failures. (Wakatsuki, Y.)

  3. Bumetanide kinetics in renal failure

    International Nuclear Information System (INIS)

    Pentikaeinen, P.J.P.; Pasternack, A.; Lampainen, E.; Neuvonen, P.J.; Penttilae, A.

    1985-01-01

    To study the effects of renal failure on bumetanide kinetics, the authors administered single intravenous doses of 1.0 mg/3.08 microCi 14 C-bumetanide to six healthy subjects and 22 patients with variable degrees of renal failure. The kinetics of 14 C-bumetanide and total 14 C were adequately described by a two-compartment open model in the control subjects and in the patients. The volume of the central compartment and the distribution t1/2 were of the same order in both groups, whereas the mean (+/- SE) volume at steady state was larger (22.1 +/- 1.6 and 16.9 +/- 1.0 L) and the elimination t1/2 was longer (1.9 +/- 0.2 and 1.4 +/- 0.1 hours) in patients with renal failure than in healthy controls. Bumetanide renal clearance was lower (10 +/- 3 and 90 +/- 13 ml/min) in patients than in subjects and correlated with creatinine clearance (r = 0.784) and log serum creatinine level (r = -0.843), whereas nonrenal clearance was significantly higher in the patients (153 +/- 14 and 99 +/- 6 ml/min). Bumetanide total plasma clearance did not significantly change. The non-protein-bound, free fraction of bumetanide was higher in patients and correlated with plasma albumin levels (r = -0.777). The kinetics of total 14 C showed similar but greater changes than those of 14C-bumetanide. Thus the most important changes in bumetanide kinetics in patients with renal failure are low renal clearance and a high free fraction, with a consequent increase in nonrenal clearance, volume of distribution, and elimination t1/2

  4. The research on the failure regularity of GM counter tubes

    International Nuclear Information System (INIS)

    Li Jiyuan; Huai Guangli; Xie Bo; Zhang Hao

    2002-01-01

    The reliability of GM counter tubes should be described by useful time before failure-life and failure rate during life. A new method to study the failure regularity of GM counter tubes is advanced and adopted. The essential point of the method is that after the GM counter tubes of the instruments in use is tested, both the performance parameters and other information of the GM counter tubes and the instruments collected are recorded. Then database is created. Failure criterion is ascertained. The GM counter tubes are inspected to determine whether they are failure. Failure mode should be decided if the GM counter tubes failure. The GM counter tubes with the same useful year come together to make up a subsample. According to the relevant information, the number of the subsample is restored to the number of the sample that initially put into use. Then the number of failure sample is counted and at the same time the distribution of failure mode is got. The parameter m, γ, t 0 of Weibull distribution function are calculated with method of linear fit. Thus mean life, failure rate and other character values are obtained. Using this method, useful life and failure rate are determined. The conclusion is that the useful life is 18-20 years and the failure rate is 5 x 10 -6 and 4 x 10 -6 /h respectively during the course

  5. Esthetic failure in implant dentistry.

    Science.gov (United States)

    Fuentealba, Rodrigo; Jofré, Jorge

    2015-01-01

    The definition of failure for dental implants has evolved from lack of osseointegration to increased concern for other aspects, such as esthetics. However, esthetic failure in implant dentistry has not been well defined. Although multiple esthetic indices have been validated for objectively evaluating clinical outcomes, including failure of an implant-supported crown, only one author has determined a failure threshold. On the basis of objective indices, esthetic failures in implant dentistry can be categorized as pink-tissue failures and white-tissue failures. This article discusses esthetic failures, the factors involved in these failures, and their prevention and treatment. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Failure Diameter Resolution Study

    Energy Technology Data Exchange (ETDEWEB)

    Menikoff, Ralph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-12-19

    Previously the SURFplus reactive burn model was calibrated for the TATB based explosive PBX 9502. The calibration was based on fitting Pop plot data, the failure diameter and the limiting detonation speed, and curvature effect data for small curvature. The model failure diameter is determined utilizing 2-D simulations of an unconfined rate stick to find the minimum diameter for which a detonation wave propagates. Here we examine the effect of mesh resolution on an unconfined rate stick with a diameter (10mm) slightly greater than the measured failure diameter (8 to 9 mm).

  7. Magnet failure workshop

    International Nuclear Information System (INIS)

    Marston, P.G.; Desportes, H.; Morpurgo, M.; Komarek, P.; Van Hulst, K.; Hackley, D.; Young, J.L.; Kibbe, K.

    1984-01-01

    The dictionary defines failure as nonperformance or an unacceptable want of success. (The definition implies that the results should have been avoided). In an emerging technology such as ours, the boundaries of expectations and ''unacceptable success'' are often ill defined. Failures are often touted as hugh successes (occasionally rightfully so) and exceptional technological achievement can become dismal failure (if expectations are too high). We all, however, have experienced problems of one sort or another and the basic purpose of the workshop was simply to communicate these so that new or future workers don't make the same mistakes

  8. A bivariate model for analyzing recurrent multi-type automobile failures

    Science.gov (United States)

    Sunethra, A. A.; Sooriyarachchi, M. R.

    2017-09-01

    The failure mechanism in an automobile can be defined as a system of multi-type recurrent failures where failures can occur due to various multi-type failure modes and these failures are repetitive such that more than one failure can occur from each failure mode. In analysing such automobile failures, both the time and type of the failure serve as response variables. However, these two response variables are highly correlated with each other since the timing of failures has an association with the mode of the failure. When there are more than one correlated response variables, the fitting of a multivariate model is more preferable than separate univariate models. Therefore, a bivariate model of time and type of failure becomes appealing for such automobile failure data. When there are multiple failure observations pertaining to a single automobile, such data cannot be treated as independent data because failure instances of a single automobile are correlated with each other while failures among different automobiles can be treated as independent. Therefore, this study proposes a bivariate model consisting time and type of failure as responses adjusted for correlated data. The proposed model was formulated following the approaches of shared parameter models and random effects models for joining the responses and for representing the correlated data respectively. The proposed model is applied to a sample of automobile failures with three types of failure modes and up to five failure recurrences. The parametric distributions that were suitable for the two responses of time to failure and type of failure were Weibull distribution and multinomial distribution respectively. The proposed bivariate model was programmed in SAS Procedure Proc NLMIXED by user programming appropriate likelihood functions. The performance of the bivariate model was compared with separate univariate models fitted for the two responses and it was identified that better performance is secured by

  9. Success and Failure Rates of 1,344 6- to 9-mm-Length Rough-Surface Implants Placed at the Time of Transalveolar Sinus Elevations, Restored with Single Crowns, and Followed for 60 to 229 Months in Function.

    Science.gov (United States)

    Fugazzotto, Paul A

    To assess the success and stability of 6-, 7-, 8-, and 9-mm-long, 6.5-mm-wide-neck tissue-level implants placed at the time of transalveolar sinus augmentation therapy, utilizing a trephine and osteotome approach, which were restored with single crowns. In total, 1,344 implants were placed by the author, varying in length from 6 to 9 mm, with parallel-wall 4.8-mm-diameter implant bodies and 6.5-mm-diameter implant necks. The implants were restored with single abutments and crowns by a variety of practitioners. They were followed for 60 to 229 months in function, with a mean time of 121.1 months in function. Implant success was evaluated by the author utilizing a combination of the Albrektsson et al criteria, and buccal and palatal/lingual bone sounding under anesthesia. The overall cumulative success rate was 98.8%. One hundred ninety 6-mm-long implants demonstrated a cumulative success rate of 97.5% at a mean time of 109.2 months in function. Eleven 7-mm-long implants demonstrated a cumulative success rate of 100% at a mean time of 218.5 months in function. One thousand ninety-four 8-mm-long implants demonstrated a cumulative success rate of 98.9% at a mean time of 112.3 months in function. Forty-nine 9-mm-long implants demonstrated a cumulative success rate of 100% at a mean time of 212.1 months in function. Implants of 6 to 9 mm in length, placed at the time of trephine and osteotome transalveolar sinus elevation procedures and restored with abutments and single crowns, demonstrate a high level of long-term clinical success, assuming specific comprehensive treatment criteria are met.

  10. Acute Kidney Failure

    Science.gov (United States)

    ... breath Acute kidney failure Symptoms & causes Diagnosis & treatment Advertisement Mayo Clinic does not endorse companies or products. ... a Job Site Map About This Site Twitter Facebook Google YouTube Pinterest Mayo Clinic is a not- ...

  11. Failure to thrive

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/000991.htm Failure to thrive To use the sharing features on ... K. Kaneshiro, MD, MHA, Clinical Professor of Pediatrics, University of Washington School of Medicine, Seattle, WA. Also ...

  12. Inverter ratio failure detector

    Science.gov (United States)

    Wagner, A. P.; Ebersole, T. J.; Andrews, R. E. (Inventor)

    1974-01-01

    A failure detector which detects the failure of a dc to ac inverter is disclosed. The inverter under failureless conditions is characterized by a known linear relationship of its input and output voltages and by a known linear relationship of its input and output currents. The detector includes circuitry which is responsive to the detector's input and output voltages and which provides a failure-indicating signal only when the monitored output voltage is less by a selected factor, than the expected output voltage for the monitored input voltage, based on the known voltages' relationship. Similarly, the detector includes circuitry which is responsive to the input and output currents and provides a failure-indicating signal only when the input current exceeds by a selected factor the expected input current for the monitored output current based on the known currents' relationship.

  13. Planning Ahead: Advanced Heart Failure

    Science.gov (United States)

    ... Thromboembolism Aortic Aneurysm More Planning Ahead: Advanced Heart Failure Updated:May 9,2017 An important part of ... This content was last reviewed May 2017. Heart Failure • Home • About Heart Failure • Causes and Risks for ...

  14. SPECT and PET in ischemic heart failure.

    Science.gov (United States)

    Angelidis, George; Giamouzis, Gregory; Karagiannis, Georgios; Butler, Javed; Tsougos, Ioannis; Valotassiou, Varvara; Giannakoulas, George; Dimakopoulos, Nikolaos; Xanthopoulos, Andrew; Skoularigis, John; Triposkiadis, Filippos; Georgoulias, Panagiotis

    2017-03-01

    Heart failure is a common clinical syndrome associated with significant morbidity and mortality worldwide. Ischemic heart disease is the leading cause of heart failure, at least in the industrialized countries. Proper diagnosis of the syndrome and management of patients with heart failure require anatomical and functional information obtained through various imaging modalities. Nuclear cardiology techniques play a main role in the evaluation of heart failure. Myocardial single photon emission computed tomography (SPECT) with thallium-201 or technetium-99 m labelled tracers offer valuable data regarding ventricular function, myocardial perfusion, viability, and intraventricular synchronism. Moreover, positron emission tomography (PET) permits accurate evaluation of myocardial perfusion, metabolism, and viability, providing high-quality images and the ability of quantitative analysis. As these imaging techniques assess different parameters of cardiac structure and function, variations of sensitivity and specificity have been reported among them. In addition, the role of SPECT and PET guided therapy remains controversial. In this comprehensive review, we address these controversies and report the advances in patient's investigation with SPECT and PET in ischemic heart failure. Furthermore, we present the innovations in technology that are expected to strengthen the role of nuclear cardiology modalities in the investigation of heart failure.

  15. Myofascial trigger point pain.

    Science.gov (United States)

    Jaeger, Bernadette

    2013-01-01

    Myofascial trigger point pain is an extremely prevalent cause of persistent pain disorders in all parts of the body, not just the head, neck, and face. Features include deep aching pain in any structure, referred from focally tender points in taut bands of skeletal muscle (the trigger points). Diagnosis depends on accurate palpation with 2-4 kg/cm2 of pressure for 10 to 20 seconds over the suspected trigger point to allow the referred pain pattern to develop. In the head and neck region, cervical muscle trigger points (key trigger points) often incite and perpetuate trigger points (satellite trigger points) and referred pain from masticatory muscles. Management requires identification and control of as many perpetuating factors as possible (posture, body mechanics, psychological stress or depression, poor sleep or nutrition). Trigger point therapies such as spray and stretch or trigger point injections are best used as adjunctive therapy.

  16. Rational points on varieties

    CERN Document Server

    Poonen, Bjorn

    2017-01-01

    This book is motivated by the problem of determining the set of rational points on a variety, but its true goal is to equip readers with a broad range of tools essential for current research in algebraic geometry and number theory. The book is unconventional in that it provides concise accounts of many topics instead of a comprehensive account of just one-this is intentionally designed to bring readers up to speed rapidly. Among the topics included are Brauer groups, faithfully flat descent, algebraic groups, torsors, étale and fppf cohomology, the Weil conjectures, and the Brauer-Manin and descent obstructions. A final chapter applies all these to study the arithmetic of surfaces. The down-to-earth explanations and the over 100 exercises make the book suitable for use as a graduate-level textbook, but even experts will appreciate having a single source covering many aspects of geometry over an unrestricted ground field and containing some material that cannot be found elsewhere. The origins of arithmetic (o...

  17. Acute decompensated heart failure: new strategies for improving outcomes [digest].

    Science.gov (United States)

    Singer Fisher, Emily; Burns, Boyd; Kim, Jeremy

    2017-05-22

    Acute decompensated heart failure is a common emergency department presentation with significant associated morbidity and mortality. Heart failure accounts for more than 1 million hospitalizations annually, with a steadily increasing incidence as our population ages. This issue reviews recent literature regarding appropriate management of emergency department presentations of acute decompensated heart failure, with special attention to newer medication options. Emergency department management and appropriate interventions are discussed, along with critical decision-making points in resuscitation for both hypertensive and hypotensive patients. [Points & Pearls is a digest of Emergency Medicine Practice].

  18. Percutaneous closure of the left atrial appendage for prevention of thromboembolism in atrial fibrillation for patients with contraindication to or failure of oral anticoagulation: a single-center experience.

    Science.gov (United States)

    Faustino, Ana; Paiva, Luís; Providência, Rui; Trigo, Joana; Botelho, Ana; Costa, Marco; Leitão-Marques, António

    2013-06-01

    In non-valvular atrial fibrillation 90% of thrombi originate in the left atrial appendage (LAA). Percutaneous LAA closure has been shown to be non-inferior to warfarin for prevention of thromboembolism. To evaluate the initial experience of a single center in percutaneous LAA closure in patients with high thromboembolic risk and in whom oral anticoagulation was impractical or contraindicated or had failed. Patients with non-valvular atrial fibrillation and CHADS2 score ≥2 in whom oral anticoagulation was impractical or contraindicated or had failed underwent percutaneous LAA closure according to the standard technique. After the procedure, dual antiplatelet therapy was maintained for one month, followed by single antiplatelet therapy indefinitely. Patients were followed by clinical assessment and transthoracic and transesophageal echocardiography. The procedure was performed in 22 of the 23 selected patients (95.7%), mean age 70±9 years, CHADS2 score 3.2±0.9 and CHA2DS2-VASC score 4.7±1.4. Intraprocedural device replacement was necessary only in the first patient, due to oversizing. The following periprocedural complications were observed: one femoral pseudoaneurysm, three femoral hematomas and two minor oropharyngeal bleeds, resolved by local hemostatic measures. During a 12±8 month follow-up a mild peri-device flow and a thrombus adhering to the device, resolved under with enoxaparin therapy, were identified. The rate of transient ischemic attack (TIA)/stroke was lower than expected according to the CHADS2 score (0 vs. 6.7±2.2%). In our initial experience, this procedure proved to be a feasible, safe and effective alternative for atrial fibrillation patients in whom oral anticoagulation is not an option. Only relatively minor complications were observed, with a lower than expected TIA/stroke rate. Copyright © 2012 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  19. Dependent failures of diesel generators

    International Nuclear Information System (INIS)

    Mankamo, T.; Pulkkinen, U.

    1982-01-01

    This survey of dependent failures (common-cause failures) is based on the data of diesel generator failures in U. S. nuclear power plants as reported in Licensee Event Reports. Failures were classified into random and potentially dependent failures. All failures due to design errors, manufacturing or installation errors, maintenance errors, or deviations in the operational environment were classified as potentially dependent failures.The statistical dependence between failures was estimated from the relative portion of multiple failures. Results confirm the earlier view of the significance of statistical dependence, a strong dependence on the age of the diesel generator was found in each failure class excluding random failures and maintenance errors, which had a nearly constant frequency independent of diesel generator age

  20. The Failure of Mandated Disclosure

    Directory of Open Access Journals (Sweden)

    Omri Ben-Shahar

    2017-12-01

    Full Text Available Objective to elaborate the conceptual theoreticallegal provisions and scientific recommendations for the substantiating the inefficiency of mandated disclosure. Methods general dialectic method of cognition as well as the general scientific and specific legal methods of research based on it. Results the article explores the spectacular prevalence and failure of the single most common technique for protecting personal autonomy in modern society mandated disclosure. The article has four parts 1 a comprehensive summary of the recurring use of mandated disclosures in many forms and circumstances in the areas of consumer and borrower protection patient informed consent contract formation and constitutional rights 2 a survey of the empirical literature documenting the failure of the mandated disclosure regime in informing people and in improving their decisions 3 an account of the multitude of reasons mandated disclosures fail focusing on the political dynamics underlying the enactments of these mandates the incentives of disclosers to carry them out and most importantly on the ability of disclosees to use them and 4 an argument that mandated disclosure not only fails to achieve its stated goal but also leads to unintended consequences that often harm the very people it intends to serve. Scientific novelty the article elaborates and introduces into academic sphere the substantiation of the efficiency of mandated disclosure proves the failure of the mandated disclosure regime in informing people and in improving their decisions and reveals the unintended consequences that often harm the very people it intends to serve. Practical significance the provisions ad conclusions of the article can be used in scientific lawmaking and lawenforcement activities and in the educational process of institutions of higher education.

  1. The Failure of Mandated Disclosures

    Directory of Open Access Journals (Sweden)

    Omri Ben-Shahar

    2017-06-01

    Full Text Available Objective to elaborate the conceptual theoreticallegal provisions and scientific recommendations for the substantiating the inefficiency of mandated disclosure. Methods general dialectic method of cognition as well as the general scientific and specific legal methods of research based on it. Results the article explores the spectacular prevalence and failure of the single most common technique for protecting personal autonomy in modern society mandated disclosure. The article has four parts 1 a comprehensive summary of the recurring use of mandated disclosures in many forms and circumstances in the areas of consumer and borrower protection patient informed consent contract formation and constitutional rights 2 a survey of the empirical literature documenting the failure of the mandated disclosure regime in informing people and in improving their decisions 3 an account of the multitude of reasons mandated disclosures fail focusing on the political dynamics underlying the enactments of these mandates the incentives of disclosers to carry them out and most importantly on the ability of disclosees to use them and 4 an argument that mandated disclosure not only fails to achieve its stated goal but also leads to unintended consequences that often harm the very people it intends to serve. Scientific novelty the article elaborates and introduces into academic sphere the substantiation of the efficiency of mandated disclosure proves the failure of the mandated disclosure regime in informing people and in improving their decisions and reveals the unintended consequences that often harm the very people it intends to serve. Practical significance the provisions ad conclusions of the article can be used in scientific lawmaking and lawenforcement activities and in the educational process of institutions of higher education.

  2. Impedance analysis of acupuncture points and pathways

    International Nuclear Information System (INIS)

    Teplan, Michal; Kukucka, Marek; Ondrejkovicová, Alena

    2011-01-01

    Investigation of impedance characteristics of acupuncture points from acoustic to radio frequency range is addressed. Discernment and localization of acupuncture points in initial single subject study was unsuccessfully attempted by impedance map technique. Vector impedance analyses determined possible resonant zones in MHz region.

  3. Impedance analysis of acupuncture points and pathways

    Science.gov (United States)

    Teplan, Michal; Kukučka, Marek; Ondrejkovičová, Alena

    2011-12-01

    Investigation of impedance characteristics of acupuncture points from acoustic to radio frequency range is addressed. Discernment and localization of acupuncture points in initial single subject study was unsuccessfully attempted by impedance map technique. Vector impedance analyses determined possible resonant zones in MHz region.

  4. Antithrombin III is associated with acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support.

    Science.gov (United States)

    Hoefer, Judith; Ulmer, Hanno; Kilo, Juliane; Margreiter, Raimund; Grimm, Michael; Mair, Peter; Ruttmann, Elfriede

    2017-06-01

    There are few data on the role of liver dysfunction in patients with end-stage heart failure supported by mechanical circulatory support. The aim of our study was to investigate predictors for acute liver failure in patients with end-stage heart failure undergoing mechanical circulatory support. A consecutive 164 patients with heart failure with New York Heart Association class IV undergoing mechanical circulatory support were investigated for acute liver failure using the King's College criteria. Clinical characteristics of heart failure together with hemodynamic and laboratory values were analyzed by logistic regression. A total of 45 patients (27.4%) with heart failure developed subsequent acute liver failure with a hospital mortality of 88.9%. Duration of heart failure, cause, cardiopulmonary resuscitation, use of vasopressors, central venous pressure, pulmonary capillary wedge pressure, pulmonary pulsatility index, cardiac index, and transaminases were not significantly associated with acute liver failure. Repeated decompensation, atrial fibrillation (P failure in univariate analysis only. In multivariable analysis, decreased antithrombin III was the strongest single measurement indicating acute liver failure (relative risk per %, 0.84; 95% confidence interval, 0.77-0.93; P = .001) and remained an independent predictor when adjustment for the Model for End-Stage Liver Disease score was performed (relative risk per %, 0.89; 95% confidence interval, 0.80-0.99; P = .031). Antithrombin III less than 59.5% was identified as a cutoff value to predict acute liver failure with a corresponding sensitivity of 81% and specificity of 87%. In addition to the Model for End-Stage Liver Disease score, decreased antithrombin III activity tends to be superior in predicting acute liver failure compared with traditionally thought predictors. Antithrombin III measurement may help to identify patients more precisely who are developing acute liver failure during mechanical

  5. Radiographic Predictors for Mechanical Failure After Adult Spinal Deformity Surgery

    DEFF Research Database (Denmark)

    Hallager, Dennis W; Karstensen, Sven; Bukhari, Naeem

    2017-01-01

    STUDY DESIGN: Retrospective cohort study at a single institution. OBJECTIVE: We aimed at estimating the rate of revision procedures and identify radiographic predictors of mechanical failure after adult spinal deformity surgery. SUMMARY OF BACKGROUND DATA: Mechanical failure rates after adult......°, the role of radiographic sagittal spine parameters and alignment targets as predictors for mechanical failure remains uncertain. METHODS: A consecutive cohort of adult spinal deformity patients who underwent corrective surgery with at least 5 levels of instrumentation between January 2008 and December 2012...... at a single tertiary spine unit were followed for at least 2 years. Time to death or failure was recorded and cause-specific Cox regressions were applied to evaluate predictors for mechanical failure or death. RESULTS: A total of 138 patients with median age of 61 years were included for analysis. Follow up...

  6. Experiments and modeling of ballistic penetration using an energy failure criterion

    Directory of Open Access Journals (Sweden)

    Dolinski M.

    2015-01-01

    Full Text Available One of the most intricate problems in terminal ballistics is the physics underlying penetration and perforation. Several penetration modes are well identified, such as petalling, plugging, spall failure and fragmentation (Sedgwick, 1968. In most cases, the final target failure will combine those modes. Some of the failure modes can be due to brittle material behavior, but penetration of ductile targets by blunt projectiles, involving plugging in particular, is caused by excessive localized plasticity, with emphasis on adiabatic shear banding (ASB. Among the theories regarding the onset of ASB, new evidence was recently brought by Rittel et al. (2006, according to whom shear bands initiate as a result of dynamic recrystallization (DRX, a local softening mechanism driven by the stored energy of cold work. As such, ASB formation results from microstructural transformations, rather than from thermal softening. In our previous work (Dolinski et al., 2010, a failure criterion based on plastic strain energy density was presented and applied to model four different classical examples of dynamic failure involving ASB formation. According to this criterion, a material point starts to fail when the total plastic strain energy density reaches a critical value. Thereafter, the strength of the element decreases gradually to zero to mimic the actual material mechanical behavior. The goal of this paper is to present a new combined experimental-numerical study of ballistic penetration and perforation, using the above-mentioned failure criterion. Careful experiments are carried out using a single combination of AISI 4340 FSP projectiles and 25[mm] thick RHA steel plates, while the impact velocity, and hence the imparted damage, are systematically varied. We show that our failure model, which includes only one adjustable parameter in this present work, can faithfully reproduce each of the experiments without any further adjustment. Moreover, it is shown that the

  7. Single ventricle cardiac defect

    International Nuclear Information System (INIS)

    Eren, B.; Turkmen, N.; Fedakar, R.; Cetin, V.

    2010-01-01

    Single ventricle heart is defined as a rare cardiac abnormality with a single ventricle chamber involving diverse functional and physiological defects. Our case is of a ten month-old baby boy who died shortly after admission to the hospital due to vomiting and diarrhoea. Autopsy findings revealed cyanosis of finger nails and ears. Internal examination revealed; large heart, weighing 60 grams, single ventricle, without a septum and upper membranous part. Single ventricle is a rare pathology, hence, this paper aims to discuss this case from a medico-legal point of view. (author)

  8. Fault failure with moderate earthquakes

    Science.gov (United States)

    Johnston, M.J.S.; Linde, A.T.; Gladwin, M.T.; Borcherdt, R.D.

    1987-01-01

    High resolution strain and tilt recordings were made in the near-field of, and prior to, the May 1983 Coalinga earthquake (ML = 6.7, ?? = 51 km), the August 4, 1985, Kettleman Hills earthquake (ML = 5.5, ?? = 34 km), the April 1984 Morgan Hill earthquake (ML = 6.1, ?? = 55 km), the November 1984 Round Valley earthquake (ML = 5.8, ?? = 54 km), the January 14, 1978, Izu, Japan earthquake (ML = 7.0, ?? = 28 km), and several other smaller magnitude earthquakes. These recordings were made with near-surface instruments (resolution 10-8), with borehole dilatometers (resolution 10-10) and a 3-component borehole strainmeter (resolution 10-9). While observed coseismic offsets are generally in good agreement with expectations from elastic dislocation theory, and while post-seismic deformation continued, in some cases, with a moment comparable to that of the main shock, preseismic strain or tilt perturbations from hours to seconds (or less) before the main shock are not apparent above the present resolution. Precursory slip for these events, if any occurred, must have had a moment less than a few percent of that of the main event. To the extent that these records reflect general fault behavior, the strong constraint on the size and amount of slip triggering major rupture makes prediction of the onset times and final magnitudes of the rupture zones a difficult task unless the instruments are fortuitously installed near the rupture initiation point. These data are best explained by an inhomogeneous failure model for which various areas of the fault plane have either different stress-slip constitutive laws or spatially varying constitutive parameters. Other work on seismic waveform analysis and synthetic waveforms indicates that the rupturing process is inhomogeneous and controlled by points of higher strength. These models indicate that rupture initiation occurs at smaller regions of higher strength which, when broken, allow runaway catastrophic failure. ?? 1987.

  9. Fault failure with moderate earthquakes

    Science.gov (United States)

    Johnston, M. J. S.; Linde, A. T.; Gladwin, M. T.; Borcherdt, R. D.

    1987-12-01

    High resolution strain and tilt recordings were made in the near-field of, and prior to, the May 1983 Coalinga earthquake ( ML = 6.7, Δ = 51 km), the August 4, 1985, Kettleman Hills earthquake ( ML = 5.5, Δ = 34 km), the April 1984 Morgan Hill earthquake ( ML = 6.1, Δ = 55 km), the November 1984 Round Valley earthquake ( ML = 5.8, Δ = 54 km), the January 14, 1978, Izu, Japan earthquake ( ML = 7.0, Δ = 28 km), and several other smaller magnitude earthquakes. These recordings were made with near-surface instruments (resolution 10 -8), with borehole dilatometers (resolution 10 -10) and a 3-component borehole strainmeter (resolution 10 -9). While observed coseismic offsets are generally in good agreement with expectations from elastic dislocation theory, and while post-seismic deformation continued, in some cases, with a moment comparable to that of the main shock, preseismic strain or tilt perturbations from hours to seconds (or less) before the main shock are not apparent above the present resolution. Precursory slip for these events, if any occurred, must have had a moment less than a few percent of that of the main event. To the extent that these records reflect general fault behavior, the strong constraint on the size and amount of slip triggering major rupture makes prediction of the onset times and final magnitudes of the rupture zones a difficult task unless the instruments are fortuitously installed near the rupture initiation point. These data are best explained by an inhomogeneous failure model for which various areas of the fault plane have either different stress-slip constitutive laws or spatially varying constitutive parameters. Other work on seismic waveform analysis and synthetic waveforms indicates that the rupturing process is inhomogeneous and controlled by points of higher strength. These models indicate that rupture initiation occurs at smaller regions of higher strength which, when broken, allow runaway catastrophic failure.

  10. Single gene deletions of mrpA to mrpG and mrpE point mutations affect activity of the Mrp Na+/H+ antiporter of alkaliphilic Bacillus and formation of hetero-oligomeric Mrp complexes.

    Science.gov (United States)

    Morino, Masato; Natsui, Shinsuke; Swartz, Talia H; Krulwich, Terry A; Ito, Masahiro

    2008-06-01

    Mrp antiporters catalyze secondary Na(+)(Li(+))/H(+) antiport and/or K(+)/H(+) antiport that is physiologically important in diverse bacteria. An additional capacity for anion flux has been observed for a few systems. Mrp is unique among antiporters in that it requires all six or seven hydrophobic gene products (MrpA to MrpG) of the mrp operon for full antiporter activity, but MrpE has been reported to be dispensable. Here, the membrane complexes formed by Mrp proteins were examined using a cloned mrp operon from alkaliphilic Bacillus pseudofirmus OF4. The operon was engineered so that the seven Mrp proteins could be detected in single samples. Membrane extracts of an antiporter-deficient Escherichia coli strain expressing this construct were analyzed by blue native-sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Mrp complexes of two sizes were identified containing all seven Mrp proteins. Studies of the single nonpolar mrp gene deletions in the construct showed that a subcomplex of MrpA, MrpB, MrpC, and MrpD was formed in the absence of MrpE, MrpF, or MrpG. By contrast, MrpE, MrpF, and MrpG were not observed in membranes lacking MrpA, MrpB, MrpC, or MrpD. Although MrpA and MrpD have been hypothesized to be the antiporter proteins, the MrpA-to-D complex was inactive. Every Mrp protein was required for an activity level near that of the wild-type Na(+)/H(+) antiporter, but a very low activity level was observed in the absence of MrpE. The introduction of an MrpE(P114G) mutation into the full Mrp complex led to antiport activity with a greatly increased apparent K(m) value for Na(+). The results suggested that interactions among the proteins of heterooligomeric Mrp complexes strongly impact antiporter properties.

  11. Ductile failure modeling

    DEFF Research Database (Denmark)

    Benzerga, Ahmed Amine; Leblond, Jean Baptiste; Needleman, Alan

    2016-01-01

    Ductile fracture of structural metals occurs mainly by the nucleation, growth and coalescence of voids. Here an overview of continuum models for this type of failure is given. The most widely used current framework is described and its limitations discussed. Much work has focused on extending void...... growth models to account for non-spherical initial void shapes and for shape changes during growth. This includes cases of very low stress triaxiality, where the voids can close up to micro-cracks during the failure process. The void growth models have also been extended to consider the effect of plastic...... anisotropy, or the influence of nonlocal effects that bring a material size scale into the models. Often the voids are not present in the material from the beginning, and realistic nucleation models are important. The final failure process by coalescence of neighboring voids is an issue that has been given...

  12. Short-Term Effects of Kinesio Taping and Cross Taping Application in the Treatment of Latent Upper Trapezius Trigger Points: A Prospective, Single-Blind, Randomized, Sham-Controlled Trial

    Directory of Open Access Journals (Sweden)

    Tomasz Halski

    2015-01-01

    Full Text Available Kinesio taping (KT may be a new treatment in patients with myofascial trigger points (MTrPs. A new method available for taping practitioners is cross taping (CT. The main objective was to determine how CT, KT, and medical adhesive tape (sham group affect the subjective assessment of resting bioelectrical activity and pain of the upper trapezius muscle (UT in patients with MTrPs. 105 volunteers were recruited to participate. The primary outcome was resting bioelectrical activity of UT muscle as assessed by surface electromyography (sEMG in each group and pain intensity on a visual analog scale (VAS. Assessments were collected before and after intervention and after the 24-hours follow-up. No significant differences were observed in bioelectrical activity of UT between pre-, post-, and follow-up results. In three groups patients had significantly lower pain VAS score after the intervention (CT—p<0.001, KT—p<0.001, and sham—p<0.01. The Kruskal-Wallis ANOVA showed no significant differences in almost all measurements between groups. The application of all three types of tapes does not influence the resting bioelectrical activity of UT muscle and may not lead to a reduction in muscle tone in the case of MTrPs.

  13. The role of targeted viral load testing in diagnosing virological failure in children on antiretroviral therapy with immunological failure.

    Science.gov (United States)

    Davies, Mary-Ann; Boulle, Andrew; Technau, Karl; Eley, Brian; Moultrie, Harry; Rabie, Helena; Garone, Daniela; Giddy, Janet; Wood, Robin; Egger, Matthias; Keiser, Olivia

    2012-11-01

    To determine the improvement in positive predictive value of immunological failure criteria for identifying virological failure in HIV-infected children on antiretroviral therapy (ART) when a single targeted viral load measurement is performed in children identified as having immunological failure. Analysis of data from children (CD4 count/per cent and HIV-RNA monitoring are performed 6-monthly. Immunological failure was defined according to both WHO 2010 and United States Department of Health and Human Services (DHHS) 2008 criteria. Confirmed virological failure was defined as HIV-RNA >5000 copies/ml on two consecutive occasions <365 days apart in a child on ART for ≥18 months. Among 2798 children on ART for ≥18 months [median (IQR) age 50 (21-84) months at ART initiation], the cumulative probability of confirmed virological failure by 42 months on ART was 6.3%. Using targeted viral load after meeting DHHS immunological failure criteria rather than DHHS immunological failure criteria alone increased positive predictive value from 28% to 82%. Targeted viral load improved the positive predictive value of WHO 2010 criteria for identifying confirmed virological failure from 49% to 82%. The addition of a single viral load measurement in children identified as failing immunologically will prevent most switches to second-line treatment in virologically suppressed children. © 2012 Blackwell Publishing Ltd.

  14. Automotive component failures

    CSIR Research Space (South Africa)

    Heyes, AM

    1998-06-01

    Full Text Available [ However\\ in the presence of a stress concentration the ultimate tensile stress can be exceeded before the ultimate shear stress is reached\\ resulting in a tensile failure 0 [ 2[6[ Metallo`raphy and Ener`y Dispersive Spectroscopy "EDS# A microspecimen...\\ Vol[ 4\\ No[ 1\\ pp[ 018 030\\ 0887 0887 Elsevier Science Ltd[ All rights reserved\\ Pergamon Printed in Great Britain 0249 5296:87 ,08[99 9[99 PII] S0249 5296"87#99909 6 AUTOMOTIVE COMPONENT FAILURES A[ M[ HEYES Advanced Engineering and Testing...

  15. Generalized Block Failure

    DEFF Research Database (Denmark)

    Jönsson, Jeppe

    2015-01-01

    Block tearing is considered in several codes as a pure block tension or a pure block shear failure mechanism. However in many situations the load acts eccentrically and involves the transfer of a substantial moment in combination with the shear force and perhaps a normal force. A literature study...... shows that no readily available tests with a well-defined substantial eccentricity have been performed. This paper presents theoretical and experimental work leading towards generalized block failure capacity methods. Simple combination of normal force, shear force and moment stress distributions along...

  16. Sensitive Troponin I Assay in Patients with Chest Pain - Association with Significant Coronary Lesions with or Without Renal Failure.

    Science.gov (United States)

    Soeiro, Alexandre de Matos; Gualandro, Danielle Menosi; Bossa, Aline Siqueira; Zullino, Cindel Nogueira; Biselli, Bruno; Soeiro, Maria Carolina Feres de Almeida; Leal, Tatiana de Carvalho Andreucci Torres; Serrano, Carlos Vicente; Oliveira Junior, Mucio Tavares de

    2018-01-01

    Despite having higher sensitivity as compared to conventional troponins, sensitive troponins have lower specificity, mainly in patients with renal failure. Study aimed at assessing the sensitive troponin I levels in patients with chest pain, and relating them to the existence of significant coronary lesions. Retrospective, single-center, observational. This study included 991 patients divided into two groups: with (N = 681) and without (N = 310) significant coronary lesion. For posterior analysis, the patients were divided into two other groups: with (N = 184) and without (N = 807) chronic renal failure. The commercial ADVIA Centaur® TnI-Ultra assay (Siemens Healthcare Diagnostics) was used. The ROC curve analysis was performed to identify the sensitivity and specificity of the best cutoff point of troponin as a discriminator of the probability of significant coronary lesion. The associations were considered significant when p renal failure, the areas under the ROC curve were 0.703 (95% CI: 0.66 - 0.74) and 0.608 (95% CI: 0.52 - 0.70), respectively. The best cutoff points to discriminate the presence of significant coronary lesion were: in the general population, 0.605 ng/dL (sensitivity, 63.4%; specificity, 67%); in patients without renal failure, 0.605 ng/dL (sensitivity, 62.7%; specificity, 71%); and in patients with chronic renal failure, 0.515 ng/dL (sensitivity, 80.6%; specificity, 42%). In patients with chest pain, sensitive troponin I showed a good correlation with significant coronary lesions when its level was greater than 0.605 ng/dL. In patients with chronic renal failure, a significant decrease in specificity was observed in the correlation of troponin levels and severe coronary lesions.

  17. The End of Points

    Science.gov (United States)

    Feldman, Jo

    2018-01-01

    Have teachers become too dependent on points? This article explores educators' dependency on their points systems, and the ways that points can distract teachers from really analyzing students' capabilities and achievements. Feldman argues that using a more subjective grading system can help illuminate crucial information about students and what…

  18. Epidemiology and Prognosis of Heart Failure

    Directory of Open Access Journals (Sweden)

    Ilaria Spoletini

    2017-01-01

    Full Text Available In this article the state of the art of prevalence, incidence and prognosis of heart failure is discussed. Prevalence and incidence are two measures of disease occurrence. Briefly, prevalence is the proportion of the population affected by the disease at a certain point in time. Incidence indicates the number of new cases within a given time period in a population at risk for the disease (for example, elderly people. A related, prognostic measure is mortality, i.e. the incidence of death from the disease occurring in a period of time. In the case of chronic, steady- state disease such as heart failure, disease duration is directly affected by mortality, and prevalence may correspond to the incidence of disease multiplied by the average duration of disease . Prevalence rates of heart failure may, therefore, vary across studies depending on the variability in incidence as well as in survival between population samples. Also, given that heart failure is a complex syndrome with different phenotypes (see article 1, each with specific clinical characteristics and associated risk factors, prevalence and incidence rates may vary according to the definition of the heart failure subtype. Finally, rates may vary on the basis of the method of collecting data and the criterion for defining left ventricular systolic dysfunction that is applied in the study.

  19. Government failure : four types

    NARCIS (Netherlands)

    Dolfsma, W.A.

    Economists tend to see the market as a default option for social order and a role for government only when markets fail. Developing a convincing analysis of the role of government in economic processes, however, needs to start by considering government failure in its own terms. Drawing on insights

  20. Beyond Success and Failure

    NARCIS (Netherlands)

    Etalle, Sandro; Jaffar, Joxan; van Raamsdonk, Femke

    We study a new programming framework based on logic programming where success and failure are replaced by predicates for adequacy and inadequacy. Adequacy allows to extract a result from a partial computation, and inadequacy allows to flexibly constrain the search space. In this parameterized

  1. Poverty and Aspirations Failure

    NARCIS (Netherlands)

    Dalton, P.S.; Ghosal, S.; Mani, A.

    2011-01-01

    We develop a theoretical framework to study the psychology of poverty and 'aspirations failure'. In our framework, the rich and the poor share the same preferences - and also a behavioral bias in setting aspirations. Greater downside risks imposed by poverty exacerbates the effects of this

  2. Poverty and aspirations failure

    NARCIS (Netherlands)

    Dalton, P.S.; Ghosal, S.; Mani, A.

    We develop a theoretical framework to study the psychology of poverty and ‘aspirations failure’, defined as the failure to aspire to one’s own potential. In our framework, rich and the poor persons share the same preferences and same behavioral bias in setting aspirations. We show that poverty can

  3. Copeptin in Heart Failure

    DEFF Research Database (Denmark)

    Balling, Louise; Gustafsson, Finn

    2016-01-01

    Heart failure (HF) is one of the most common causes of hospitalization and mortality in the modern Western world and an increasing proportion of the population will be affected by HF in the future. Although HF management has improved quality of life and prognosis, mortality remains very high...

  4. Heart failure overview

    Science.gov (United States)

    ... Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Internal review and update on 09/01/2016 by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the A.D.A.M. Editorial team. Heart Failure Read more NIH MedlinePlus Magazine Read more Health ...

  5. Perioperative acute renal failure.

    LENUS (Irish Health Repository)

    Mahon, Padraig

    2012-02-03

    PURPOSE OF REVIEW: Recent biochemical evidence increasingly implicates inflammatory mechanisms as precipitants of acute renal failure. In this review, we detail some of these pathways together with potential new therapeutic targets. RECENT FINDINGS: Neutrophil gelatinase-associated lipocalin appears to be a sensitive, specific and reliable biomarker of renal injury, which may be predictive of renal outcome in the perioperative setting. For estimation of glomerular filtration rate, cystatin C is superior to creatinine. No drug is definitively effective at preventing postoperative renal failure. Clinical trials of fenoldopam and atrial natriuretic peptide are, at best, equivocal. As with pharmacological preconditioning of the heart, volatile anaesthetic agents appear to offer a protective effect to the subsequently ischaemic kidney. SUMMARY: Although a greatly improved understanding of the pathophysiology of acute renal failure has offered even more therapeutic targets, the maintenance of intravascular euvolaemia and perfusion pressure is most effective at preventing new postoperative acute renal failure. In the future, strategies targeting renal regeneration after injury will use bone marrow-derived stem cells and growth factors such as insulin-like growth factor-1.

  6. Acute liver failure

    DEFF Research Database (Denmark)

    Bernal, William; Lee, William M; Wendon, Julia

    2015-01-01

    Over the last three decades acute liver failure (ALF) has been transformed from a rare and poorly understood condition with a near universally fatal outcome, to one with a well characterized phenotype and disease course. Complex critical care protocols are now applied and emergency liver...

  7. Heart failure - discharge

    Science.gov (United States)

    ... of Medicine, Division of Cardiology, Harborview Medical Center, University of Washington Medical School, Seattle, WA. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the A.D.A.M. Editorial team. Related MedlinePlus Health Topics Heart Failure Browse the Encyclopedia A.D.A.M., Inc. ...

  8. Failures of Socialization.

    Science.gov (United States)

    Hogan, Robert; Sloan, Tod

    1984-01-01

    Discusses the incidence of crime (and other indicators of alienation) for school-aged, young Americans in terms of sociological variables. Draws on the tradition of research in culture and personality to interpret these failures of socialization in terms of certain widespread changes in patterns of child-rearing. (Author/JAC)

  9. Diuretics for heart failure.

    Science.gov (United States)

    Faris, Rajaa F; Flather, Marcus; Purcell, Henry; Poole-Wilson, Philip A; Coats, Andrew J S

    2012-02-15

    Chronic heart failure is a major cause of morbidity and mortality worldwide. Diuretics are regarded as the first-line treatment for patients with congestive heart failure since they provide symptomatic relief. The effects of diuretics on disease progression and survival remain unclear. To assess the harms and benefits of diuretics for chronic heart failure Updated searches were run in the Cochrane Central Register of Controlled Trials in The Cochrane Library (CENTRAL Issue 1 of 4, 2011), MEDLINE (1966 to 22 February 2011), EMBASE (1980 to 2011 Week 07) and HERDIN database (1990 to February 2011). We hand searched pertinent journals and reference lists of papers were inspected. We also contacted manufacturers and researchers in the field. No language restrictions were applied. Double-blinded randomised controlled trials of diuretic therapy comparing one diuretic with placebo, or one diuretic with another active agent (e.g. ACE inhibitors, digoxin) in patients with chronic heart failure. Two authors independently abstracted the data and assessed the eligibility and methodological quality of each trial. Extracted data were analysed by determining the odds ratio for dichotomous data, and difference in means for continuous data, of the treated group compared with controls. The likelihood of heterogeneity of the study population was assessed by the Chi-square test. If there was no evidence of statistical heterogeneity and pooling of results was clinically appropriate, a combined estimate was obtained using the fixed-effects model. This update has not identified any new studies for inclusion. The review includes 14 trials (525 participants), 7 were placebo-controlled, and 7 compared diuretics against other agents such as ACE inhibitors or digoxin. We analysed the data for mortality and for worsening heart failure. Mortality data were available in 3 of the placebo-controlled trials (202 participants). Mortality was lower for participants treated with diuretics than for

  10. C2 Failures: A Taxonomy and Analysis

    Science.gov (United States)

    2013-06-01

    1989, Apr. 15 United Kingdom (Sheffield, England) 96 deaths [15] Hurricane Andrew 1992, Aug. 24 United States (Florida) 26 direct deaths, 39...Victorian Bushfires Royal Commission (2010), p.8 Hurricane Andrew Response "...failure to have a single person in charge with a clear chain of command...communications infrastructure. This happened during Hurricane Andrew , 31 Hurricane Katrina, 32 and the Indian Ocean Tsunami. 33 Even if not substantially

  11. OBSTETRIC RENAL FAILURE

    Directory of Open Access Journals (Sweden)

    Rajeshwari

    2015-11-01

    Full Text Available Renal failure in obstetrics is rare but important complication, associated with significant mortality and long term morbidity.1,2 It includes acute renal failure due to obstetrical complications or due to deterioration of existing renal disease. AIMS AND OBJECTIVES: To evaluate the etiology and outcome of renal failure in obstetric patients. METHODS: We prospectively analyzed 30 pregnant and puerperal women with acute renal failure or pre-existing renal disease developing renal failure during pregnancy between November 2007 to sep-2009. Patients who presented/developed ARF during the hospital stay were included in this study. RESULTS: Among 30 patients, mean age was 23 years and 33 years age group. 12 cases (40% patients were primigravidae and 9(30% patients were multigravidae and 9 cases (30% presented in post-partum period. Eighteen cases (60% with ARF were seen in third trimester, followed by in postpartum period 9 cases (30%. Most common contributing factors to ARF were Pre-eclampsia, eclampsia and HELLP syndrome 60%, sepsis 56.6%, post abortal ARF 10%. DIC 40%. Haemorrhage as the aetiology for ARF was present 46%, APH in 20% and PPH in 26.6%. The type of ARF was renal in (63% and prerenal (36%; Oliguric seen in 10 patients (33% and high mortality (30%. Among the 20 pregnant patients with ARF, The average period of gestation was 33±2 weeks (30 -36 weeks, 5 cases (25% presented with intrauterine fetal demise and 18 cases (66% had preterm vaginal delivery and 2 cases (10% had induced abortion. And the average birth weight was 2±0.5 kg (1.5 kg. Eight cases (26% required dialysis. 80% of patients recovered completely of renal functions. 63% patients recovered without renal replacement therapy whereas 17% required dialysis. the maternal mortality was 20%, the main reason for mortality was septic shock and multi organ dysfunction (66%. CONCLUSION: ARF related pregnancy was seen commonly in the primigravidae and in the third trimester, the most

  12. Metaharmonic Lattice Point Theory

    CERN Document Server

    Freeden, Willi

    2011-01-01

    Metaharmonic Lattice Point Theory covers interrelated methods and tools of spherically oriented geomathematics and periodically reflected analytic number theory. The book establishes multi-dimensional Euler and Poisson summation formulas corresponding to elliptic operators for the adaptive determination and calculation of formulas and identities of weighted lattice point numbers, in particular the non-uniform distribution of lattice points. The author explains how to obtain multi-dimensional generalizations of the Euler summation formula by interpreting classical Bernoulli polynomials as Green

  13. Flat Coalgebraic Fixed Point Logics

    Science.gov (United States)

    Schröder, Lutz; Venema, Yde

    Fixed point logics are widely used in computer science, in particular in artificial intelligence and concurrency. The most expressive logics of this type are the μ-calculus and its relatives. However, popular fixed point logics tend to trade expressivity for simplicity and readability, and in fact often live within the single variable fragment of the μ-calculus. The family of such flat fixed point logics includes, e.g., CTL, the *-nesting-free fragment of PDL, and the logic of common knowledge. Here, we extend this notion to the generic semantic framework of coalgebraic logic, thus covering a wide range of logics beyond the standard μ-calculus including, e.g., flat fragments of the graded μ-calculus and the alternating-time μ-calculus (such as ATL), as well as probabilistic and monotone fixed point logics. Our main results are completeness of the Kozen-Park axiomatization and a timed-out tableaux method that matches ExpTime upper bounds inherited from the coalgebraic μ-calculus but avoids using automata.

  14. Autoimmune premature ovarian failure

    Directory of Open Access Journals (Sweden)

    Beata Komorowska

    2017-02-01

    Full Text Available Premature ovarian failure (POF, also termed as primary ovarian insufficiency (POI, is a highly heterogenous condition affecting 0.5-3.0% of women in childbearing age. These young women comprise quite a formidable group with unique physical and psychological needs that require special attention. Premature ovarian senescence (POS in all of its forms evolves insidiously as a basically asymptomatic process, leading to complete loss of ovarian function, and POI/POF diagnoses are currently made at relatively late stages. Well-known and well-documented risk factors exist, and the presence or suspicion of autoimmune disorder should be regarded as an important one. Premature ovarian failure is to some degree predictable in its occurrence and should be considered while encountering young women with loss of menstrual regularity, especially when there is a concomitant dysfunction in the immune system.

  15. Rate based failure detection

    Science.gov (United States)

    Johnson, Brett Emery Trabun; Gamage, Thoshitha Thanushka; Bakken, David Edward

    2018-01-02

    This disclosure describes, in part, a system management component and failure detection component for use in a power grid data network to identify anomalies within the network and systematically adjust the quality of service of data published by publishers and subscribed to by subscribers within the network. In one implementation, subscribers may identify a desired data rate, a minimum acceptable data rate, desired latency, minimum acceptable latency and a priority for each subscription. The failure detection component may identify an anomaly within the network and a source of the anomaly. Based on the identified anomaly, data rates and or data paths may be adjusted in real-time to ensure that the power grid data network does not become overloaded and/or fail.

  16. Reliability analysis based on the losses from failures.

    Science.gov (United States)

    Todinov, M T

    2006-04-01

    The conventional reliability analysis is based on the premise that increasing the reliability of a system will decrease the losses from failures. On the basis of counterexamples, it is demonstrated that this is valid only if all failures are associated with the same losses. In case of failures associated with different losses, a system with larger reliability is not necessarily characterized by smaller losses from failures. Consequently, a theoretical framework and models are proposed for a reliability analysis, linking reliability and the losses from failures. Equations related to the distributions of the potential losses from failure have been derived. It is argued that the classical risk equation only estimates the average value of the potential losses from failure and does not provide insight into the variability associated with the potential losses. Equations have also been derived for determining the potential and the expected losses from failures for nonrepairable and repairable systems with components arranged in series, with arbitrary life distributions. The equations are also valid for systems/components with multiple mutually exclusive failure modes. The expected losses given failure is a linear combination of the expected losses from failure associated with the separate failure modes scaled by the conditional probabilities with which the failure modes initiate failure. On this basis, an efficient method for simplifying complex reliability block diagrams has been developed. Branches of components arranged in series whose failures are mutually exclusive can be reduced to single components with equivalent hazard rate, downtime, and expected costs associated with intervention and repair. A model for estimating the expected losses from early-life failures has also been developed. For a specified time interval, the expected losses from early-life failures are a sum of the products of the expected number of failures in the specified time intervals covering the

  17. Failure by design?

    DEFF Research Database (Denmark)

    Moyo, Francis; Ijumba, Jasper; Lund, Jens Friis

    2016-01-01

    In this paper, we revisit the on-the-ground reality of Burunge Wildlife Management Area (WMA) that is celebrated as one of Tanzania's best examples of community-based conservation (CBC). We find Burunge WMA rife with conflict and contestation over grievances that remained unsettled since its esta...... failure to address this detrimental discrepancy between reality and representation, and start supporting affected residents in their struggles for self-determination....

  18. Failures of chain systems

    CSIR Research Space (South Africa)

    James, A

    1997-03-01

    Full Text Available ?C and intermittent exposure at 400--450 ?C. Unlike structural steels, which become softer and more ductile when reheated in service, manga- nese steels become brittle when reheated sufficiently to induce carbide... to form a roughly oval shaped crack until the link section could no longer withstand the applied loading experienced during normal dragline operations, and this resulted in final fast brittle failure. The general...

  19. Psychopedagogy and school failure

    OpenAIRE

    Mabel Fresquet, Adriana

    2012-01-01

    This paper aims to analyze Lhe relationship between psychopedagogy and school failure, emphasizing potential actions of Lhe former to avoid unsuccesses in school. From a historic-cultural perspective, the concept of proximal developmental zone is discussed to explain Lhe region of inter-subjective action that characterizes psychopedagogical tasks. The latter goes beyond Lhe teacher-"student" duality to become a space of social inter-subjectivity of teacher-"students". In this sense, psyc...

  20. Bitter taste – cheese failure

    Directory of Open Access Journals (Sweden)

    Slavko Kirin

    2001-10-01

    Full Text Available Bitter taste is serous and very often cheese failure in modern cheesemaking process. In this paper the sources and bitter taste development in cheese will be presented. Bitterness in cheese is linked to bitter compounds development during cheese ripening. Most of the bitter compounds come from bitter peptides, the mechanism of theirs development being due to proteasepeptidase system of the cured enzymes and the milk cultures as well as other proteases present in cheese. By the action of curd enzymes, the milk protein - casein - is firstly degraded into high molecular weight compounds possessing no bitter taste. Those compounds are then degraded, by milk protease cultures, to hydrophobic bitter peptides of low molecular weight further degraded, by bacterial endopeptidase during cheese ripening, to bitter peptides and amino acids. In the case when no balance exists, between bitter compounds development and breakdown by lactic acid bacteria peptidase, an accumulation of bitter peptides occurs thus having an influence on cheese bitterness. During cheese ripening naturally occurring milk protease – plasmin, and thermostable proteases of raw milk microflora are also involved in proteolytic process. Fat cheese lipases, initiated by lipase originating from psychrotrophic bacteria in raw milk as well as other cheese lipases, are also associated with bitter taste generation. The other sources of bitterness come from the forages, the medicament residues as well as washing and disinfecting agents. In order to eliminate these failures a special care should be taken in milk quality as well as curd and milk culture selection. At this point technological norms and procedures, aimed to maintain the proteolysis balance during cheese ripening, should be adjusted, thus eliminating the bitter taste of the cheese.

  1. Catastrophic Failure and Critical Scaling Laws of Fiber Bundle Material

    Directory of Open Access Journals (Sweden)

    Shengwang Hao

    2017-05-01

    Full Text Available This paper presents a spring-fiber bundle model used to describe the failure process induced by energy release in heterogeneous materials. The conditions that induce catastrophic failure are determined by geometric conditions and energy equilibrium. It is revealed that the relative rates of deformation of, and damage to the fiber bundle with respect to the boundary controlling displacement ε0 exhibit universal power law behavior near the catastrophic point, with a critical exponent of −1/2. The proportion of the rate of response with respect to acceleration exhibits a linear relationship with increasing displacement in the vicinity of the catastrophic point. This allows for the prediction of catastrophic failure immediately prior to failure by extrapolating the trajectory of this relationship as it asymptotes to zero. Monte Carlo simulations are completed and these two critical scaling laws are confirmed.

  2. Catastrophic Failure and Critical Scaling Laws of Fiber Bundle Material.

    Science.gov (United States)

    Hao, Shengwang; Yang, Hang; Liang, Xiangzhou

    2017-05-09

    This paper presents a spring-fiber bundle model used to describe the failure process induced by energy release in heterogeneous materials. The conditions that induce catastrophic failure are determined by geometric conditions and energy equilibrium. It is revealed that the relative rates of deformation of, and damage to the fiber bundle with respect to the boundary controlling displacement ε ₀ exhibit universal power law behavior near the catastrophic point, with a critical exponent of -1/2. The proportion of the rate of response with respect to acceleration exhibits a linear relationship with increasing displacement in the vicinity of the catastrophic point. This allows for the prediction of catastrophic failure immediately prior to failure by extrapolating the trajectory of this relationship as it asymptotes to zero. Monte Carlo simulations are completed and these two critical scaling laws are confirmed.

  3. Data and Statistics: Heart Failure

    Science.gov (United States)

    ... Blood Pressure Salt Cholesterol Million Hearts® WISEWOMAN Heart Failure Fact Sheet Recommend on Facebook Tweet Share Compartir ... mean that the heart has stopped beating. Heart Failure in the United States About 5.7 million ...

  4. Heart failure - fluids and diuretics

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000112.htm Heart failure - fluids and diuretics To use the sharing features on this page, please enable JavaScript. Heart failure is a condition in which the heart is ...

  5. Heart failure in Nigerian hypertensives.

    Science.gov (United States)

    Falase, A O; Ayeni, O; Sekoni, G A; Odia, O J

    1983-03-01

    A study of 209 consecutive cases of hypertension, seen at the cardiac unit of the University College Hospital, Ibadan, Nigeria, showed that heart failure occurred more commonly in patients who were in the low socio-economic class. All those who had a haematocrit below 30% had heart failure. The lower the serum albumin, the greater the likelihood of developing heart failure. Hypertensives who were heavy alcohol drinkers were very prone to heart failure while a significant proportion of those who had cardiomegaly or cardiomegaly with aortic unfolding on chest x-ray had heart failure. Age, sex, Hb genotype, obesity and retinal changes had no influence on the development of heart failure. It is concluded that there are other factors, besides hypertension, which precipitate heart failure in Nigerian hypertensives. This may be responsible for the high incidence of heart failure among Nigerian with hypertension.

  6. Heart Failure in the Elderly

    NARCIS (Netherlands)

    B. Cost (Bernard)

    2000-01-01

    textabstractHeart failure is a clinical syndrome with various causes for which no universally accepted definition exists. Packer's definition of heart failure "representing a complex clinical syndrome characterised by abnonnalities of left ventricular function and neurohumoral regulation. which are

  7. Interesting Interest Points

    DEFF Research Database (Denmark)

    Aanæs, Henrik; Dahl, Anders Lindbjerg; Pedersen, Kim Steenstrup

    2012-01-01

    Not all interest points are equally interesting. The most valuable interest points lead to optimal performance of the computer vision method in which they are employed. But a measure of this kind will be dependent on the chosen vision application. We propose a more general performance measure bas...

  8. Poisson branching point processes

    International Nuclear Information System (INIS)

    Matsuo, K.; Teich, M.C.; Saleh, B.E.A.

    1984-01-01

    We investigate the statistical properties of a special branching point process. The initial process is assumed to be a homogeneous Poisson point process (HPP). The initiating events at each branching stage are carried forward to the following stage. In addition, each initiating event independently contributes a nonstationary Poisson point process (whose rate is a specified function) located at that point. The additional contributions from all points of a given stage constitute a doubly stochastic Poisson point process (DSPP) whose rate is a filtered version of the initiating point process at that stage. The process studied is a generalization of a Poisson branching process in which random time delays are permitted in the generation of events. Particular attention is given to the limit in which the number of branching stages is infinite while the average number of added events per event of the previous stage is infinitesimal. In the special case when the branching is instantaneous this limit of continuous branching corresponds to the well-known Yule--Furry process with an initial Poisson population. The Poisson branching point process provides a useful description for many problems in various scientific disciplines, such as the behavior of electron multipliers, neutron chain reactions, and cosmic ray showers

  9. Indexing Moving Points

    DEFF Research Database (Denmark)

    Agarwal, Pankaj K.; Arge, Lars Allan; Erickson, Jeff

    2003-01-01

    We propose three indexing schemes for storing a set S of N points in the plane, each moving along a linear trajectory, so that any query of the following form can be answered quickly: Given a rectangle R and a real value t, report all K points of S that lie inside R at time t. We first present an...

  10. Model Breaking Points Conceptualized

    Science.gov (United States)

    Vig, Rozy; Murray, Eileen; Star, Jon R.

    2014-01-01

    Current curriculum initiatives (e.g., National Governors Association Center for Best Practices and Council of Chief State School Officers 2010) advocate that models be used in the mathematics classroom. However, despite their apparent promise, there comes a point when models break, a point in the mathematical problem space where the model cannot,…

  11. Multispectral Image Feature Points

    Directory of Open Access Journals (Sweden)

    Cristhian Aguilera

    2012-09-01

    Full Text Available This paper presents a novel feature point descriptor for the multispectral image case: Far-Infrared and Visible Spectrum images. It allows matching interest points on images of the same scene but acquired in different spectral bands. Initially, points of interest are detected on both images through a SIFT-like based scale space representation. Then, these points are characterized using an Edge Oriented Histogram (EOH descriptor. Finally, points of interest from multispectral images are matched by finding nearest couples using the information from the descriptor. The provided experimental results and comparisons with similar methods show both the validity of the proposed approach as well as the improvements it offers with respect to the current state-of-the-art.

  12. Failure to Thrive (For Parents)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Failure to Thrive KidsHealth / For Parents / Failure to Thrive What's in ... child back into a healthy growth pattern. About Failure to Thrive Although it's been recognized for more than a ...

  13. A Failure Criterion for Concrete

    DEFF Research Database (Denmark)

    Ottosen, N. S.

    1977-01-01

    A four-parameter failure criterion containing all the three stress invariants explicitly is proposed for short-time loading of concrete. It corresponds to a smooth convex failure surface with curved meridians, which open in the negative direction of the hydrostatic axis, and the trace...... are given for three typical ratios. A review of some earlier proposed failure criteria is included....

  14. Failure Rates in Introductory Programming

    DEFF Research Database (Denmark)

    Bennedsen, Jens; Caspersen, Michael Edelgaard

    2007-01-01

    It is a common conception that CS1 is a very difficult course and that failure rates are high. However, until now there has only been anecdotal evidence for this claim. This article reports on a survey among institutions around the world regarding failure rates in introductory programming courses...... solid proof of the actual failure and pass rates of CS1....

  15. Single-photon imaging

    CERN Document Server

    Seitz, Peter

    2011-01-01

    The acquisition and interpretation of images is a central capability in almost all scientific and technological domains. In particular, the acquisition of electromagnetic radiation, in the form of visible light, UV, infrared, X-ray, etc. is of enormous practical importance. The ultimate sensitivity in electronic imaging is the detection of individual photons. With this book, the first comprehensive review of all aspects of single-photon electronic imaging has been created. Topics include theoretical basics, semiconductor fabrication, single-photon detection principles, imager design and applications of different spectral domains. Today, the solid-state fabrication capabilities for several types of image sensors has advanced to a point, where uncoooled single-photon electronic imaging will soon become a consumer product. This book is giving a specialist´s view from different domains to the forthcoming “single-photon imaging” revolution. The various aspects of single-photon imaging are treated by internati...

  16. Uncertainty analysis of point by point sampling complex surfaces using touch probe CMMs

    DEFF Research Database (Denmark)

    Barini, Emanuele; Tosello, Guido; De Chiffre, Leonardo

    2007-01-01

    The paper describes a study concerning point by point scanning of complex surfaces using tactile CMMs. A four factors-two level full factorial experiment was carried out, involving measurements on a complex surface configuration item comprising a sphere, a cylinder and a cone, combined in a singl...

  17. Revisiting Formability and Failure of AISI304 Sheets in SPIF: Experimental Approach and Numerical Validation

    Directory of Open Access Journals (Sweden)

    Gabriel Centeno

    2017-11-01

    Full Text Available Single Point Incremental Forming (SPIF is a flexible and economic manufacturing process with a strong potential for manufacturing small and medium batches of highly customized parts. Formability and failure in SPIF have been intensively discussed in recent years, especially because this process allows stable plastic deformation well above the conventional forming limits, as this enhanced formability is only achievable within a certain range of process parameters depending on the material type. This paper analyzes formability and failure of AISI304-H111 sheets deformed by SPIF compared to conventional testing conditions (including Nakazima and stretch-bending tests. With this purpose, experimental tests in SPIF and stretch-bending were carried out and a numerical model of SPIF is performed. The results allow the authors to establish the following contributions regarding SPIF: (i the setting of the limits of the formability enhancement when small tool diameters are used, (ii the evolution of the crack when failure is attained and (iii the determination of the conditions upon which necking is suppressed, leading directly to ductile fracture in SPIF.

  18. Heart failure - palliative care

    Science.gov (United States)

    ... with your doctors and loved ones may help bring you peace of mind. You may have already discussed heart transplantation and the use of a ventricular assist device with your doctor. At some point, you will ...

  19. ANALYSIS OF RELIABILITY OF NONRECTORABLE REDUNDANT POWER SYSTEMS TAKING INTO ACCOUNT COMMON FAILURES

    Directory of Open Access Journals (Sweden)

    V. A. Anischenko

    2014-01-01

    Full Text Available Reliability Analysis of nonrestorable redundant power Systems of industrial plants and other consumers of electric energy was carried out. The main attention was paid to numbers failures influence, caused by failures of all elements of System due to one general reason. Noted the main possible reasons of common failures formation. Two main indicators of reliability of non-restorable systems are considered: average time of no-failure operation and mean probability of no-failure operation. Modeling of failures were carried out by mean of division of investigated system into two in-series connected subsystems, one of them indicated independent failures, but the other indicated common failures. Due to joined modeling of single and common failures resulting intensity of failures is the amount incompatible components: intensity statistically independent failures and intensity of common failures of elements and system in total.It is shown the influence of common failures of elements on average time of no-failure operation of system. There is built the scale of preference of systems according to criterion of  average time maximum of no-failure operation, depending on portion of common failures. It is noticed that such common failures don’t influence on the scale of preference, but  change intervals of time, determining the moments of systems failures and excepting them from the number of comparators. There were discussed two problems  of conditionally optimization of  systems’  reservation choice, taking into account their reliability and cost. The first problem is solved due to criterion of minimum cost of system providing mean probability of no-failure operation, the second problem is solved due to criterion of maximum of mean probability of no-failure operation with cost limitation of system.

  20. Do acupuncture points exist?

    International Nuclear Information System (INIS)

    Yan Xiaohui; Zhang Xinyi; Liu Chenglin; Dang, Ruishan; Huang Yuying; He Wei; Ding Guanghong

    2009-01-01

    We used synchrotron x-ray fluorescence analysis to probe the distribution of four chemical elements in and around acupuncture points, two located in the forearm and two in the lower leg. Three of the four acupuncture points showed significantly elevated concentrations of elements Ca, Fe, Cu and Zn in relation to levels in the surrounding tissue, with similar elevation ratios for Cu and Fe. The mapped distribution of these elements implies that each acupuncture point seems to be elliptical with the long axis along the meridian. (note)

  1. Do acupuncture points exist?

    Energy Technology Data Exchange (ETDEWEB)

    Yan Xiaohui; Zhang Xinyi [Department of Physics, Surface Physics Laboratory (State Key Laboratory), and Synchrotron Radiation Research Center of Fudan University, Shanghai 200433 (China); Liu Chenglin [Physics Department of Yancheng Teachers' College, Yancheng 224002 (China); Dang, Ruishan [Second Military Medical University, Shanghai 200433 (China); Huang Yuying; He Wei [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100039 (China); Ding Guanghong [Shanghai Research Center of Acupuncture and Meridian, Pudong, Shanghai 201203 (China)

    2009-05-07

    We used synchrotron x-ray fluorescence analysis to probe the distribution of four chemical elements in and around acupuncture points, two located in the forearm and two in the lower leg. Three of the four acupuncture points showed significantly elevated concentrations of elements Ca, Fe, Cu and Zn in relation to levels in the surrounding tissue, with similar elevation ratios for Cu and Fe. The mapped distribution of these elements implies that each acupuncture point seems to be elliptical with the long axis along the meridian. (note)

  2. Tissue microarray profiling in human heart failure.

    Science.gov (United States)

    Lal, Sean; Nguyen, Lisa; Tezone, Rhenan; Ponten, Fredrik; Odeberg, Jacob; Li, Amy; Dos Remedios, Cristobal

    2016-09-01

    Tissue MicroArrays (TMAs) are a versatile tool for high-throughput protein screening, allowing qualitative analysis of a large number of samples on a single slide. We have developed a customizable TMA system that uniquely utilizes cryopreserved human cardiac samples from both heart failure and donor patients to produce formalin-fixed paraffin-embedded sections. Confirmatory upstream or downstream molecular studies can then be performed on the same (biobanked) cryopreserved tissue. In a pilot study, we applied our TMAs to screen for the expression of four-and-a-half LIM-domain 2 (FHL2), a member of the four-and-a-half LIM family. This protein has been implicated in the pathogenesis of heart failure in a variety of animal models. While FHL2 is abundant in the heart, not much is known about its expression in human heart failure. For this purpose, we generated an affinity-purified rabbit polyclonal anti-human FHL2 antibody. Our TMAs allowed high-throughput profiling of FHL2 protein using qualitative and semiquantitative immunohistochemistry that proved complementary to Western blot analysis. We demonstrated a significant relative reduction in FHL2 protein expression across different forms of human heart failure. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Provisional crown failures in dental school predoctoral clinics.

    Science.gov (United States)

    Hyde, Jeffrey D; Bader, James A; Shugars, Daniel A

    2007-11-01

    Following a preliminary study indicating that at least 10 percent of single-unit crown temporary restorations failed in patients who received treatment by predoctoral students, a comprehensive examination of provisional crown failure was initiated to identify strategies to reduce the failure rate. For all provisionalized, natural tooth, single-unit crown preparations in University of North Carolina School of Dentistry predoctoral clinics for one year (N=1008), we noted tooth type, type of crown, student level, faculty coverage experience, treatment clinic, temporary material and luting agent, and retreatment (failure) of the provisional restoration. For failures, we also noted the stage of crown preparation at failure and the time since initial placement of the temporary. We analyzed these data using simple cross-tabs and logistic regression on need for retreatment (alpha =0.05). The failure rate was 18.75 percent (N=189). The median time to failure was twelve days; the 25(th) and 75(th) percentiles were six and twenty-six days. Significant risk factors, in order of odds ratio estimates, were molar tooth, second- or third-year student, and inexperienced faculty. Most provisional failures occurred during the final preparation phase of treatment. Provisional restoration failure is more frequent than was initially suspected from preliminary studies. Strategies for institutional intervention to reduce provisional restoration failure include greater attention to evaluating provisional crowns placed by inexperienced students (sophomores and juniors) and placing more emphasis on the retentiveness of provisional restorations reused following the final impression. Review of provisional evaluation procedures is also indicated for faculty who do not routinely supervise these procedures.

  4. Rapid Prototyping by Single Point Incremental Forming of Sheet Metal

    DEFF Research Database (Denmark)

    Skjødt, Martin

    2008-01-01

    explains a lot of experimental observation seen in the literature. SPIF of tailored blanks produced by friction stir welding. It is demonstrated that SPIF of tailored sheets produced by friction stir welding is possible and a promising way of combining two innovative manufacturing processes. Multi stage...

  5. Single point methods for determining blast wave injury

    NARCIS (Netherlands)

    Teland, J.A.; Doormaal, J.C.A.M. van; Horst, M.J. van der; Svinsas, E.

    2011-01-01

    Models for calculating human injury from a blast wave are examined. The Axelsson BTD model is able to give injury estimates also for complex shock waves, but is difficult to use in practise since it requires input from four pressure sensors on a BTD (Blast Test Device) in the specific location. To

  6. Transition at the deliquesce point in single salts

    DEFF Research Database (Denmark)

    Rörig-Dalgaard, Inge

    2014-01-01

    of the CS is the thermoelectric module which is a small wafer composed of PN semiconductor layers. When current passes through these elements, one side of the wafer heats and the opposite one cools. Reversing the polarity switches cold and hot sides. This is refered to as the Peltier effect. With the CS...

  7. Enhancing RGI lyase thermostability by targeted single point mutations

    DEFF Research Database (Denmark)

    Silva, Inês R.; Larsen, Dorte Møller; Jers, Carsten

    2013-01-01

    Rhamnogalacturonan I lyase (RGI lyase) (EC 4.2.2.-) catalyzes the cleavage of rhamnogalacturonan I in pectins by β-elimination. In this study the thermal stability of a RGI lyase (PL 11) originating from Bacillus licheniformis DSM 13/ATCC14580 was increased by a targeted protein engineering...

  8. Wear monitoring of single point cutting tool using acoustic emission ...

    Indian Academy of Sciences (India)

    This paper examines the flank and crater wear characteristics of coated carbide tool inserts during dry turning of steel workpieces. A brief review of tool wear mechanisms is presented together with new evidence showing that wear of the TiC layer on both flank and rake faces is dominated by discrete plastic deformation, ...

  9. Single service point: it's all in the design.

    Science.gov (United States)

    Bradigan, Pamela S; Rodman, Ruey L

    2008-01-01

    "Design thinking" principles from a leading design firm, IDEO, were key elements in the planning process for a one-desk service model, the ASK Desk, at the John A. Prior Health Sciences Library. The library administration and staff employed the methodology to enhance customer experiences, meet technology challenges, and compete in a changing education environment. The most recent renovations demonstrate how the principles were applied. The concept of "continuous design thinking" is important in the library's daily operations to serve customers most effectively.

  10. Diffusion of fish from a single release point

    DEFF Research Database (Denmark)

    Sparrevohn, Claus Reedtz; Nielsen, Anders; Støttrup, Josianne

    2002-01-01

    In a field experiment, 3529 turbot (Psetta maxima) were released in order to estimate and describe the movements of hatchery-reared fish by applying diffusion theory. After liberation, the development of the population density was estimated during the following 9 days, and from that, the rate...... that the sampling of fish during the experiment did not have any detectable effect on the population density. The activity of the released turbot resulted in an individual daily displacement of 151 m-day(-1), except for the first 2 days at liberty, where the displacement was estimated to be considerably lower....... Advection was significant and was related to the displacement of the water body. Further, it was possible to estimate the postrelease mortality as 14%.day(-1) and the catchability of the turbot when caught with a young fish trawl as 28%....

  11. Wear monitoring of single point cutting tool using acoustic emission ...

    Indian Academy of Sciences (India)

    It clearly indicates that the three stages of wear viz., Stage I, where the rate of wear is low, Stage II, where the rate of wear is moderate and. Stage III, where the rate of wear is faster and leading to the termination of tool life. In stage I, 0 to 8.5 min of the machining operation the tool wear is in the range of 0–8.3 μm only.

  12. Wear monitoring of single point cutting tool using acoustic emission ...

    Indian Academy of Sciences (India)

    Blum & Inasaki (1990) have stated in their research investigations that a wide variety of measure- ment s can be carried out according to the type of AE signal, the experimental instrumentation used and the personal preferences of the individual research workers. One of the most signifi- cant methods to analyse AE is the ...

  13. Failure and nonfailure of fluid filaments in extension

    DEFF Research Database (Denmark)

    Hassager, Ole; Kolte, Mette Irene; Renardy, Michael

    1998-01-01

    The phenomenon of ductile failure of Newtonian and viscoelastic fluid filaments without surface tension is studied by a 2D finite element method and by ID non-linear analysis. The viscoelastic fluids are described by single integral constitutive equations. The main conclusions are: (1) Newtonian...... fluid filaments do not exhibit ductile failure without surface tension; (2) some viscoelastic fluids form stable filaments while other fluids exhibit ductile failure as a result of an elastic instability; (3) for large Deborah numbers, the Considere condition may be used to predict the Hencky strain...

  14. Formation of failure matrix and failure-free control algorithm for multi-sectioned Switched-reluctance drive

    Science.gov (United States)

    Odnokopylov, G.; Rozayev, I.

    2014-10-01

    We review fault-tolerant switched reluctance drive with sectioning of the three-phase stator winding. In the operating process of an electric drive, there will be continuous monitoring of the operating state on the basis of a developed algorithm to analyse drive operability and formation tabulate a failure matrix. The paper introduces a failure-free control algorithm for multi-section switch - reluctance motor with formation the assignment values of amplitude phase currents taking into account the failure matrix. We show that in an emergency such single failure or multiple failure in switched-reluctance drive it is possible to provide reduction of torque fall and pro-gressively stock depletion with providing fault-tolerance of drive system. A method of residual life evaluation is proposed on the basis of calculating the coefficient of operability of the electric drive system that gives possibility to control the endurance of electric drive in real time from operational to completely unusable.

  15. Steam generator tube failures

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

  16. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  17. Renal insufficiency and failure.

    Science.gov (United States)

    Dimopoulos, Meletios A; Terpos, Evangelos

    2010-01-01

    Renal impairment is a common complication of multiple myeloma. Chronic renal failure is classified according to glomerular filtration rate as estimated by the MDRD (modification of diet in renal disease) formula, while RIFLE (risk, injury, failure, loss and end-stage renal disease) and AKIN (acute renal injury network) criteria may be used for the definition of the severity of acute renal injury. Novel criteria based on estimated glomerular filtration rate measurements are proposed for the definition of the reversibility of renal impairment. Renal complete response (CRrenal) is defined as sustained (i.e., lasting at least 2 months) improvement of creatinine clearance (CRCL) from under 50 mL/min at baseline to 60 mL/min or above. Renal partial response (PRrenal) is defined as sustained improvement of CRCL from under 15 mL/min at baseline to 30 to 59 mL/min. Renal minor response (MRrenal) is defined as sustained improvement of the baseline CRCL of under 15 mL/min to 15 to 29 mL/min or, if baseline CRCL was 15 to 29 mL/min, improvement to 30 to 59 mL/min. Bortezomib with high-dose dexamethasone is considered the treatment of choice for myeloma patients with renal impairment and improves renal function in most patients. Although there is limited experience with thalidomide, this agent can be administered at the standard dosage to patients with renal failure. Lenalidomide, when administered at reduced doses according to renal function, is effective and can reverse renal impairment in a subset of myeloma patients.

  18. The Point Lepreau Desktop Simulator

    International Nuclear Information System (INIS)

    MacLean, M.; Hogg, J.; Newman, H.

    1997-01-01

    The Point Lepreau Desktop Simulator runs plant process modeling software on a 266 MHz single CPU DEC Alpha computer. This same Alpha also runs the plant control computer software on an SSCI 125 emulator. An adjacent Pentium PC runs the simulator's Instructor Facility software, and communicates with the Alpha through an Ethernet. The Point Lepreau Desktop simulator is constructed to be as similar as possible to the Point Lepreau full scope training simulator. This minimizes total maintenance costs and enhances the benefits of the desktop simulator. Both simulators have the same modeling running on a single CPU in the same schedule of calculations. Both simulators have the same Instructor Facility capable of developing and executing the same lesson plans, doing the same monitoring and control of simulations, inserting all the same malfunctions, performing all the same overrides, capable of making and restoring all the same storepoints. Both simulators run the same plant control computer software - the same assembly language control programs as the power plant uses for reactor control, heat transport control, annunciation, etc. This is a higher degree of similarity between a desktop simulator and a full scope training simulator than previously reported for a computer controlled nuclear plant. The large quantity of control room hardware missing from the desktop simulator is replaced by software. The Instructor Facility panel override software of the training simulator provides the means by which devices (switches, controllers, windows, etc.) on the control room panels can be controlled and monitored in the desktop simulator. The CRT of the Alpha provides a mouse operated DCC keyboard mimic for controlling the plant control computer emulation. Two emulated RAMTEK display channels appear as windows for monitoring anything of interest on plant DCC displays, including one channel for annunciation. (author)

  19. Premature ovarian failure

    Directory of Open Access Journals (Sweden)

    Persani Luca

    2006-04-01

    Full Text Available Abstract Premature ovarian failure (POF is a primary ovarian defect characterized by absent menarche (primary amenorrhea or premature depletion of ovarian follicles before the age of 40 years (secondary amenorrhea. It is a heterogeneous disorder affecting approximately 1% of women e.g. Turner syndrome represent the major cause of primary amenorrhea associated with ovarian dysgenesis. Despite the description of several candidate genes, the cause of POF remains undetermined in the vast majority of the cases. Management includes substitution of the hormone defect by estrogen/progestin preparations. The only solution presently available for the fertility defect in women with absent follicular reserve is ovum donation.

  20. Acute Liver Failure.

    Science.gov (United States)

    Newland, Catherine D

    2016-12-01

    Pediatric acute liver failure (ALF) is a complex and rapidly progressive syndrome that results from a variety of age-dependent etiologies. It is defined by the acute onset of liver disease with no evidence of chronic liver disease. There must be biochemical or clinical evidence of severe liver dysfunction as defined by an international normalized ratio (INR) ≥2. If hepatic encephalopathy is present, INR should be ≥1.5. Unfortunately, due to the rarity of ALF in pediatric patients, there is a paucity of diagnostic and management algorithms and each patient must have an individualized approach. [Pediatr Ann. 2016;45(12):e433-e438.]. Copyright 2016, SLACK Incorporated.