WorldWideScience

Sample records for single monolithic centralized

  1. Broadband EM Performance Characteristics of Single Square Loop FSS Embedded Monolithic Radome

    Directory of Open Access Journals (Sweden)

    Raveendranath U. Nair

    2013-01-01

    Full Text Available A monolithic half-wave radome panel, centrally loaded with aperture-type single square loop frequency selective surface (SSL-FSS, is proposed here for broadband airborne radome applications. Equivalent transmission line method in conjunction with equivalent circuit model (ECM is used for modeling the SSL-FSS embedded monolithic half-wave radome panel and evaluating radome performance parameters. The design parameters of the SSL-FSS are optimized at different angles of incidence such that the new radome wall configuration offers superior EM performance from L-band to X-band as compared to the conventional monolithic half-wave slab of identical material and thickness. The superior EM performance of SSL-FSS embedded monolithic radome wall makes it suitable for the design of normal incidence and streamlined airborne radomes.

  2. Fabrication of single-walled carbon nanohorns incorporated a monolithic column for capillary electrochromatography.

    Science.gov (United States)

    Zhao, Hongyan; Wang, Yizhou; Cheng, Heyong; Wang, Yuanchao

    2017-08-01

    Single-walled carbon nanohorns have received great interest for their unique properties and diverse potential applications. Herein, we demonstrated the feasibility of single-walled carbon nanohorns incorporated poly(styrene-divinylbenzene) monolith as the stationary phase for capillary electrochromatography, which were prepared by one-step in situ copolymerization. Single-walled carbon nanohorns were dispersed in styrene to give a stable and homogeneous suspension. The monolithic column gave effective separation for a wide range of aromatic compounds, which was based on hydrophobicity and π-π electrostatic stacking of single-walled carbon nanohorns. The precisions of migration time and peak area varied in the ranges of 1.4-1.9% for intraday trials and 1.7-3.5% for interday trials, and 3.2-6.7% for intraday trials and 4.1-7.4% for interday trials, and 3.6-7.2% for inter-column trials and 5.2-21.3% for inter-column trials, respectively, indicating the good reproducibility of single-walled carbon nanohorns embedded monolithic columns. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Single-mode quantum cascade lasers employing a candy-cane shaped monolithic coupled cavity

    Science.gov (United States)

    Liu, Peter Q.; Sladek, Kamil; Wang, Xiaojun; Fan, Jen-Yu; Gmachl, Claire F.

    2011-12-01

    We demonstrate single-mode quantum cascade lasers emitting at ˜4.5 μm by employing a monolithic "candy-cane" shaped coupled-cavity consisting of a straight section connecting at one end to a spiral section. The fabrication process is identical to those for simple Fabry-Perot-type ridge lasers. Continuously tunable single-mode emission across ˜8 cm-1 with side mode suppression ratio up to ˜25 dB and a single-mode operating current range of more than 70% above the threshold current is achieved when the lasers are operated in pulsed-mode from 80 K to 155 K.

  4. Monolithic spectrometer

    Science.gov (United States)

    Rajic, Slobodan; Egert, Charles M.; Kahl, William K.; Snyder, Jr., William B.; Evans, III, Boyd M.; Marlar, Troy A.; Cunningham, Joseph P.

    1998-01-01

    A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.

  5. Complete digital workflow for the production of implant-supported single-unit monolithic crowns.

    Science.gov (United States)

    Joda, Tim; Brägger, Urs

    2014-11-01

    The aim of this case series was to introduce a complete digital workflow for the production of monolithic implant crowns. Six patients were treated with implant-supported crowns made of resin nano ceramic (RNC). Starting with an intraoral optical scan (IOS), and following a CAD/CAM process, the monolithic crowns were bonded either to a novel prefabricated titanium abutment base (group A) or to a CAD/CAM-generated individualized titanium abutment (group B) in premolar or molar sites on a soft tissue level dental implant. Economic analyses included clinical and laboratory steps. An esthetic evaluation was performed to compare the two abutment-crown combinations. None of the digitally constructed RNC crowns required any clinical adaptation. Overall mean work time calculations revealed obvious differences for group A (65.3 min) compared with group B (86.5 min). Esthetic analysis demonstrated a more favorable outcome for the prefabricated bonding bases. Prefabricated or individualized abutments on monolithic RNC crowns using CAD/CAM technology in a model-free workflow seem to provide a feasible and streamlined treatment approach for single-edentulous space rehabilitation in the posterior region. However, RNC as full-contour material has to be considered experimental, and further large-scale clinical investigations with long-term follow-up observation are necessary. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. On-chip III-V monolithic integration of heralded single photon sources and beamsplitters

    Science.gov (United States)

    Belhassen, J.; Baboux, F.; Yao, Q.; Amanti, M.; Favero, I.; Lemaître, A.; Kolthammer, W. S.; Walmsley, I. A.; Ducci, S.

    2018-02-01

    We demonstrate a monolithic III-V photonic circuit combining a heralded single photon source with a beamsplitter, at room temperature and telecom wavelength. Pulsed parametric down-conversion in an AlGaAs waveguide generates counterpropagating photons, one of which is used to herald the injection of its twin into the beamsplitter. We use this configuration to implement an integrated Hanbury-Brown and Twiss experiment, yielding a heralded second-order correlation gher(2 )(0 )=0.10 ±0.02 that confirms single-photon operation. The demonstrated generation and manipulation of quantum states on a single III-V semiconductor chip opens promising avenues towards real-world applications in quantum information.

  7. Short-Term Prospective Clinical Evaluation of Monolithic and Partially Veneered Zirconia Single Crowns.

    Science.gov (United States)

    Bömicke, Wolfgang; Rammelsberg, Peter; Stober, Thomas; Schmitter, Marc

    2017-02-01

    The purpose of this study was to prospectively evaluate the short-term clinical performance and esthetics of monolithic and partially (i.e., facially) veneered zirconia single crowns (MZC and PZC, respectively). Between September 2011 and June 2013, 68 participants received 90 MZCs and 72 PZCs. Clinical study documentation was performed at crown cementation (baseline), at the 6-month follow-up, and then yearly thereafter using standardized report forms. Eight participants with 14 single crowns (eight MZCs and six PZCs) dropped out during clinical follow-up. Thus, 60 participants (28 male, mean age 62.5 ± 13.1 years) fitted with 82 MZCs and 66 PZCs were analyzed in February 2016 (Kaplan-Meier survival; mean observation time for the restorations 35.1 ± 6.3 months). Descriptive statistics were calculated for participants' and dentists' esthetic ratings on a numerical rating scale from 0 to 10 (0 = unacceptable color and shape; 10 = excellent color and shape). Complications were predominantly biological in nature. One PZC was affected by minor chipping. Cumulative 3-year failure-free survival was 98.5% (standard error (SE), 1.5%) for both MZCs and PZCs. Three-year cumulative complication-free survival (success) was 93.6% (SE 2.8%) for MZCs and 95.5% (SE 2.6%) for PZCs. Three-year cumulative fracture-free survival was 100% for MZCs and 98.5% (SE 1.5%) for PZCs. Crowns of both types were awarded high esthetic scores by participants and dentists. Monolithic and partially veneered zirconia crowns can be used clinically with excellent short-term survival and success and without compromising esthetic appearance. Longer-term follow-up is, however, desirable. During the observation time, both monolithic and partially veneered zirconia crowns showed an outstanding low technical complication rate: only one minor chipping and three losses of retention were observed. Additionally, esthetics was excellent. Based on these results the clinical use of this kind of

  8. Monolithic carbon structures including suspended single nanowires and nanomeshes as a sensor platform.

    Science.gov (United States)

    Lim, Yeongjin; Heo, Jeong-Il; Madou, Marc; Shin, Heungjoo

    2013-11-20

    With the development of nanomaterial-based nanodevices, it became inevitable to develop cost-effective and simple nanofabrication technologies enabling the formation of nanomaterial assembly in a controllable manner. Herein, we present suspended monolithic carbon single nanowires and nanomeshes bridging two bulk carbon posts, fabricated in a designed manner using two successive UV exposure steps and a single pyrolysis step. The pyrolysis step is accompanied with a significant volume reduction, resulting in the shrinkage of micro-sized photoresist structures into nanoscale carbon structures. Even with the significant elongation of the suspended carbon nanowire induced by the volume reduction of the bulk carbon posts, the resultant tensional stress along the nanowire is not significant but grows along the wire thickness; this tensional stress gradient and the bent supports of the bridge-like carbon nanowire enhance structural robustness and alleviate the stiction problem that suspended nanostructures frequently experience. The feasibility of the suspended carbon nanostructures as a sensor platform was demonstrated by testing its electrochemical behavior, conductivity-temperature relationship, and hydrogen gas sensing capability.

  9. Monolithic-Structured Single-Layered Textile-Based Dye-Sensitized Solar Cells

    Science.gov (United States)

    Yun, Min Ju; Cha, Seung I.; Kim, Han Seong; Seo, Seon Hee; Lee, Dong Y.

    2016-10-01

    Textile-structured solar cells are frequently discussed in the literature due to their prospective applications in wearable devices and in building integrated solar cells that utilize their flexibility, mechanical robustness, and aesthetic appearance, but the current approaches for textile-based solar cells—including the preparation of fibre-type solar cells woven into textiles—face several difficulties from high friction and tension during the weaving process. This study proposes a new structural concept and fabrication process for monolithic-structured textile-based dye-sensitized solar cells that are fabricated by a process similar to the cloth-making process, including the preparation of wires and yarns that are woven for use in textiles, printed, dyed, and packaged. The fabricated single-layered textile-based dye-sensitized solar cells successfully act as solar cells in our study, even under bending conditions. By controlling the inter-weft spacing and the number of Ti wires for the photoelectrode conductor, we have found that the performance of this type of dye-sensitized solar cell was notably affected by the spacing between photoelectrodes and counter-electrodes, the exposed areas of Ti wires to photoelectrodes, and photoelectrodes’ surface morphology. We believe that this study provides a process and concept for improved textile-based solar cells that can form the basis for further research.

  10. Monolithic-Structured Single-Layered Textile-Based Dye-Sensitized Solar Cells

    Science.gov (United States)

    Yun, Min Ju; Cha, Seung I.; Kim, Han Seong; Seo, Seon Hee; Lee, Dong Y.

    2016-01-01

    Textile-structured solar cells are frequently discussed in the literature due to their prospective applications in wearable devices and in building integrated solar cells that utilize their flexibility, mechanical robustness, and aesthetic appearance, but the current approaches for textile-based solar cells—including the preparation of fibre-type solar cells woven into textiles—face several difficulties from high friction and tension during the weaving process. This study proposes a new structural concept and fabrication process for monolithic-structured textile-based dye-sensitized solar cells that are fabricated by a process similar to the cloth-making process, including the preparation of wires and yarns that are woven for use in textiles, printed, dyed, and packaged. The fabricated single-layered textile-based dye-sensitized solar cells successfully act as solar cells in our study, even under bending conditions. By controlling the inter-weft spacing and the number of Ti wires for the photoelectrode conductor, we have found that the performance of this type of dye-sensitized solar cell was notably affected by the spacing between photoelectrodes and counter-electrodes, the exposed areas of Ti wires to photoelectrodes, and photoelectrodes’ surface morphology. We believe that this study provides a process and concept for improved textile-based solar cells that can form the basis for further research. PMID:27708359

  11. Load-bearing capacity and the recommended thickness of dental monolithic zirconia single crowns.

    Science.gov (United States)

    Sun, Ting; Zhou, Shanyu; Lai, Renfa; Liu, Ruoyu; Ma, Shuyuan; Zhou, Zhiying; Longquan, Shao

    2014-07-01

    The aim of this study was to evaluate the load bearing capacity and a reasonable thicknesss of dental monolithic zirconia crowns. Polymethyl methacrylate (PMMA) abutment tooth specimens were made by CAD/CAM technic. Monolithic zirconia crowns (MZC), monolithic lithium disilicate crowns (MLC), layered zirconia crowns (LZC) and metal ceramic crowns(MCC), of which the occlusal thickness was 1.5mm were thereafter fabricated and cemented on the abutment tooth specimens. MCC with occlusal thicknesses of 0.6mm, 0.8mm, 1.00mm, 1.2mm were also made. All specimens underwent load-to-fracture test. Weibull parameters (σ0) and (m) were calculated. Fracture modes were also evaluated. The mean fracture load was 1863.16±116.81 for MLC, 2284.77±355.60 for MCC, 2308.0±510.94 for LZC, 4109.93±610.18 for MZC (1.5mm), 3068.31±233.88 for MZC (1.2mm), 2429.88±315.03 for MZC (1.0mm), 1814.60±68.21 for MZC (0.8mm) and 1308.38±111.38 for MZC (0.6mm). The fracture load of MZC was significantly higher than MCC, LZC and MLC (P0.05). Monolithic zirconia crowns exhibit higher fracture loads than monolithic lithium disilicate crowns, layered zirconia crowns and metal ceramic crowns. The fracture resistance of monolithic zirconia crowns with a thickness of 1.0mm can be equal to metal ceramic crowns. Doubling the monolithic zirconia core from 0.6mm to 1.5mm increases the fracture resistance of this restorative system threefold. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. High magnetic field trapping in monolithic single-grain YBa2Cu3O(7-delta) bulk materials

    Science.gov (United States)

    Gao, L.; Xue, Y. Y.; Ramirez, D.; Huang, Z. J.; Meng, R. L.; Chu, C. W.

    1993-01-01

    Results of our study on high magnetic field trapping in unirradiated, high quality monolithic single-grain YBa2Cu3O(7-delta) disks are reported. A record high 4 T trapped field at the surface of the unirradiated disks is observed. However, below 11 K, large flux avalanches caused by thermal instability severely limit the remnant trapped field. Therefore, flux avalanche, rather than Jc x d, dictates the maximum trapped field at low temperatures. To overcome this problem, a strong high temperature superconductor trapped field magnet is proposed. A novel application of the avalanche effect is also mentioned.

  13. Monolithic lithium-disilicate single crowns supported by zirconia oral implants: three-year results of a prospective cohort study.

    Science.gov (United States)

    Spies, Benedikt Christopher; Patzelt, Sebastian Berthold Maximilian; Vach, Kirstin; Kohal, Ralf-Joachim

    2016-09-01

    To determine the survival and success rate of CAD/CAM-fabricated monolithic lithium-disilicate crowns supported by zirconia oral implants after 3 years. Twenty-four patients in need of a single tooth replacement received a zirconia implant and were finally restored with 24 single crowns (SCs) ground out of pre-crystallized lithium-disilicate blanks. The restorations were adhesively cemented and evaluated using modified United States Public Health Service (USPHS) criteria. In case of clinically relevant defects that could be repaired to an acceptable level, SCs were regarded as surviving. Restorations with minor chippings, a small-area roughness (ø esthetics, sense, and speech. Monolithic lithium-disilicate SCs supported by zirconia implants showed promising survival and success rates after an observation period of 3 years. It remains to be seen whether the further observation period confirms this positive results. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Monolithic Ytterbium All-single-mode Fiber Laser with Direct Fiber-end Delivery of nJ-level Femtosecond Pulses

    DEFF Research Database (Denmark)

    Turchinovich, Dmitry

    2008-01-01

    We demonstrate a monolithic, i.e. without any free-space coupling, all-single-mode passively modelocked Yb-fiber laser, with direct fiber-end delivery of 364−405 fs pulses of 4 nJ pulse energy using a low-loss hollow-core photonic crystal fiber compression.......We demonstrate a monolithic, i.e. without any free-space coupling, all-single-mode passively modelocked Yb-fiber laser, with direct fiber-end delivery of 364−405 fs pulses of 4 nJ pulse energy using a low-loss hollow-core photonic crystal fiber compression....

  15. Monolithic column in gas chromatography.

    Science.gov (United States)

    Kurganov, A

    2013-05-02

    Monolithic columns invented in chromatographic praxis almost 40 years ago gained nowadays a lot of popularity in separations by liquid chromatographic technique. At the same time, application of monolithic columns in gas chromatography is less common and only a single review published by Svec et al. covers this field of research. Since that time a lot of new findings on application and properties of monolithic columns in gas chromatography have been published in the literature deserving consideration and discussion. This review considers preparation of monolithic columns for GC, an impact of preparation conditions on column performance, optimization of separation conditions for GC analysis on monolithic columns and other important aspects of preparation and usage of monolithic capillary columns in GC. A final part of the review discusses the modern trends and possible applications in the future of capillary monolithic columns in GC. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Single-step synthesis of monolithic comb-like CdS nanostructures with tunable waveguide properties.

    Science.gov (United States)

    Liu, Ruibin; Li, Zi-An; Zhang, Chunhua; Wang, Xiaoxu; Kamran, Muhammad A; Farle, Michael; Zou, Bingsuo

    2013-06-12

    Using a simple in situ seeding chemical vapor deposition (CVD) process, comb-like (branched) monolithic CdS micro/nanostructures were grown. Efficient optical coupling between the backbone and the teeth of the branched architecture is demonstrated by distributing light from an UV-laser-excited spot at one end of the backbone to all branch tips. By varying the deposition conditions, the orientation of the branches with respect to the backbone, their size and density can be tuned as well as the size of the backbone. This in situ seeding CVD method has the potential for a low-cost single-step fabrication of high-quality, micro/nanointegrated photonic devices, with tunable complex waveguiding possibilities.

  17. Stable single-frequency output at 2.01 microm from a diode-pumped monolithic double diffusion-bonded Tm:YAG nonplanar ring oscillator at room temperature.

    Science.gov (United States)

    Gao, Chunqing; Gao, Mingwei; Zhang, Yunshan; Lin, Zhifeng; Zhu, Lingni

    2009-10-01

    We demonstrate a monolithic double diffusion-bonded monolithic Tm:YAG nonplanar ring laser pumped by a fiber-coupled laser diode. Up to 867 mW single-frequency output at 2.01 microm was obtained from the Tm:YAG system at room temperature, with a slope efficiency and an optical-optical efficiency of 31.6% and 19.2%. The power stability of the single frequency laser was 0.32% within 30 min.

  18. Monolithic lithium disilicate complete single crowns with feather-edge preparation design in the posterior region: A multicentric retrospective study up to 12 years.

    Science.gov (United States)

    Schmitz, Johannes H; Cortellini, Davide; Granata, Stefano; Valenti, Marco

    2017-07-20

    This retrospective study evaluated the clinical success and survival of monolithic lithium disilicate single crowns in the posterior region fabricated with feather-edge margins and cemented with resin-based self-etching cement. In total, 627 pressed monolithic lithium disilicate restorations on posterior teeth (110 first premolars, 151 second premolars, 240 first molars, 121 second molars, 5 third molars) were placed in 335 patients. All teeth were prepared with feather-edge margins and restored with single crowns. The modified California Dental Association criteria were used to clinically evaluate subjects during regular maintenance recalls. The mean follow-up time was 48.17 months (SD, 27.7; range, 6 to 144). Nine crowns were replaced during the follow-up period due to bulk fracture of the material (overall 97.93% survival rate), and four teeth were extracted. No other technical or biologic failure was observed. In this retrospective evaluation, monolithic lithium disilicate crowns with feather-edge margins yielded clinical outcomes similar to those reported with other margin designs and materials. Following the same clinical protocol, crowns on second molars showed lower survival rates when compared to restorations on other teeth in the posterior region. Careful evaluation is mandatory in high-risk patients and terminal teeth. Alternative restorative materials, such as full-contour zirconia crowns, should be considered for the restoration of second molars.

  19. High-Precision Displacement Sensing of Monolithic Piezoelectric Disk Resonators Using a Single-Electron Transistor

    Science.gov (United States)

    Li, J.; Santos, J. T.; Sillanpää, M. A.

    2018-02-01

    A single-electron transistor (SET) can be used as an extremely sensitive charge detector. Mechanical displacements can be converted into charge, and hence, SETs can become sensitive detectors of mechanical oscillations. For studying small-energy oscillations, an important approach to realize the mechanical resonators is to use piezoelectric materials. Besides coupling to traditional electric circuitry, the strain-generated piezoelectric charge allows for measuring ultrasmall oscillations via SET detection. Here, we explore the usage of SETs to detect the shear-mode oscillations of a 6-mm-diameter quartz disk resonator with a resonance frequency around 9 MHz. We measure the mechanical oscillations using either a conventional DC SET, or use the SET as a homodyne or heterodyne mixer, or finally, as a radio-frequency single-electron transistor (RF-SET). The RF-SET readout is shown to be the most sensitive method, allowing us to measure mechanical displacement amplitudes below 10^{-13} m. We conclude that a detection based on a SET offers a potential to reach the sensitivity at the quantum limit of the mechanical vibrations.

  20. Direct monolithic integration of vertical single crystalline octahedral molecular sieve nanowires on silicon

    Energy Technology Data Exchange (ETDEWEB)

    Carretero-Genevrier, Adrian [Institut des Nanotechnologies de Lyon (INL), UMR-CNRS 5270, Ecole Central de Lyon, Ecully (France); Institut de Ciencia de Materials de Barcelona ICMAB, Catalonia (Spain); Sorbonne Univ., UPMC Univ. Paris 06, CNRS, College de France, Paris (France); Oro-Sole, Judith [Institut de Ciencia de Materials de Barcelona ICMAB, Catalonia (Spain); Gazquez, Jaume [Institut de Ciencia de Materials de Barcelona ICMAB, Catalonia (Spain); Magen, Cesar [Univ. de Zaragoza, Zaragoza (Spain); Miranda, Laura [Sorbonne Univ., UPMC Univ. Paris 06, CNRS, College de France, Paris (France); Puig, Teresa [Institut de Ciencia de Materials de Barcelona ICMAB, Catalonia (Spain); Obradors, Xavier [Institut de Ciencia de Materials de Barcelona ICMAB, Catalonia (Spain); Ferain, Etienne [Univ. Catholique de Louvain, Louvain-la-Neuve (Belgium); Sanchez, Clement [Sorbonne Univ., UPMC Univ. Paris 06, CNRS, College de France, Paris (France); Rodriguez-Carvajal, Juan [Institut Laue-Langevin, Grenoble Cedex (France); Mestres, Narcis [Institut de Ciencia de Materials de Barcelona ICMAB, Catalonia (Spain)

    2013-12-13

    We developed an original strategy to produce vertical epitaxial single crystalline manganese oxide octahedral molecular sieve (OMS) nanowires with tunable pore sizes and compositions on silicon substrates by using a chemical solution deposition approach. The nanowire growth mechanism involves the use of track-etched nanoporous polymer templates combined with the controlled growth of quartz thin films at the silicon surface, which allowed OMS nanowires to stabilize and crystallize. α-quartz thin films were obtained after thermal activated crystallization of the native amorphous silica surface layer assisted by Sr2+- or Ba2+-mediated heterogeneous catalysis in the air at 800 °C. These α-quartz thin films work as a selective template for the epitaxial growth of randomly oriented vertical OMS nanowires. Furthermore, the combination of soft chemistry and epitaxial growth opens new opportunities for the effective integration of novel technological functional tunneled complex oxides nanomaterials on Si substrates.

  1. Clinical Results and Technical Complications of Posterior Implant-Supported Modified Monolithic Zirconia Single Crowns and Short-Span Fixed Dental Prostheses: A 2-Year Pilot Study.

    Science.gov (United States)

    Cheng, Chih-Wen; Chien, Chia-Hui; Chen, Chun-Jung; Papaspyridakos, Panos

    2018-02-01

    The purpose of this clinical trial was to investigate the clinical outcomes of implant-supported modified monolithic zirconia single crowns (SCs) and short-span fixed dental prostheses (FDPs) after a follow-up of 2 years. Twenty-seven patients in need of implant-supported SCs or 3-unit FDPs in the posterior maxilla or mandible were consecutively selected for this study. A total of 56 modified monolithic zirconia prostheses including 44 SCs (8 screw-retained, 36 cement-retained) and twelve 3-unit FDPs (5 screw-retained, 7 cement-retained) were included in this study. All patients were followed at 6 months, 12 months, 18 months, and 2 years after placement of the modified monolithic zirconia prostheses. During the follow-up period, all prostheses were evaluated with clinical and radiographic examinations. The following technical parameters were assessed: framework fracture, fracture of veneering porcelain, screw loosening, loss of retention because of prosthesis de-cementation and opposing tooth fracture. No implant was lost during the follow-up period, yielding a 2-year implant survival of 100%. One FDP failed because of framework fracture. The overall prosthesis survival rate was 98.2% after 2 years of clinical service. During the study, 5 complication events were observed in 3 SCs and one FDP, including one fracture of veneering porcelain and 2 screw loosenings in 3 SCs, and loss of retention and opposing tooth fracture in the same FDP. Therefore, the complication-free rate of prostheses was 91.1%. According to the results of this study, the modified monolithic zirconia design used in this study resulted in a favorable short-term outcome for posterior implant-supported SCs and 3-unit FDPs. © 2017 by the American College of Prosthodontists.

  2. First demonstration and field trial on multi-user UDWDM-PON full duplex PSK-PSK with single monolithic integrated dual-output-DFB-SOA based ONUs.

    Science.gov (United States)

    Chu, GuangYong; Maho, Anaëlle; Cano, Iván; Polo, Victor; Brenot, Romain; Debrégeas, Hélène; Prat, Josep

    2016-10-15

    We demonstrate a monolithically integrated dual-output DFB-SOA, and conduct the field trial on a multi-user bidirectional coherent ultradense wavelength division multiplexing-passive optical network (UDWDM-PON). To the best of our knowledge, this is the first achievement of simplified single integrated laser-based neighboring coherent optical network units (ONUs) with a 12.5 GHz channel spaced ultra-dense access network, including both downstream and upstream, taking the benefits of low footprint and low-temperature dependence.

  3. Monolithic integration of InGaN segments emitting in the blue, green, and red spectral range in single ordered nanocolumns

    Energy Technology Data Exchange (ETDEWEB)

    Albert, S.; Bengoechea-Encabo, A.; Sanchez-Garcia, M. A.; Calleja, E. [ISOM and Dept. Ingenieria Electronica, ETSI Telecomunicacion, Universidad Politecnica de Madrid, Ciudad Universitaria s/n, 28040 Madrid (Spain); Kong, X.; Trampert, A. [Paul-Drude-Institut fuer Festkoeperelektronik, Hausvogteiplatz 5-7, 10117 Berlin (Germany)

    2013-05-06

    This work reports on the selective area growth by plasma-assisted molecular beam epitaxy and characterization of InGaN/GaN nanocolumnar heterostructures. The optimization of the In/Ga and total III/V ratios, as well as the growth temperature, provides control on the emission wavelength, either in the blue, green, or red spectral range. An adequate structure tailoring and monolithic integration in a single nanocolumnar heterostructure of three InGaN portions emitting in the red-green-blue colors lead to white light emission.

  4. Brain malformation in single median maxillary central incisor

    DEFF Research Database (Denmark)

    Kjaer, I; Wagner, Aa; Thomsen, L L

    2009-01-01

    Clinical and radiographic examinations and MR scan of a 12-year-old girl with SMMCI (single median maxillary central incisor) showed impaired growth and a midline defect involving the central incisor, cranium and the midline structures in the brain, falx cerebri and pituitary gland. She had a sev...

  5. Monolithic ceramics

    Science.gov (United States)

    Herbell, Thomas P.; Sanders, William A.

    1992-01-01

    A development history and current development status evaluation are presented for SiC and Si3N4 monolithic ceramics. In the absence of widely sought improvements in these materials' toughness, and associated reliability in structural applications, uses will remain restricted to components in noncritical, nonman-rated aerospace applications such as cruise missile and drone gas turbine engine components. In such high temperature engine-section components, projected costs lie below those associated with superalloy-based short-life/expendable engines. Advancements are required in processing technology for the sake of fewer and smaller microstructural flaws.

  6. Experiments and analysis of tunable monolithic 1- μm single-frequency fiber lasers with loop mirror filters

    Science.gov (United States)

    Wang, Qi; Song, Huaqing; Wang, Xingpeng; Wang, Dongdong; Li, Li

    2018-03-01

    In this paper, we demonstrated thermally tunable 1- μm single-frequency fiber lasers utilizing loop mirror filters (LMFs) with unpumped Yb-doped fibers. The frequency selection and tracking was achieved by combining a fiber Bragg grating (FBG) and a dynamic grating established inside the LMF. The central emission wavelength was at 1064.07 nm with a tuning range of 1.4 nm, and the measured emission linewidth was less than 10 kHz. We also systematically studied the wavelength-tracking thermal stability of the LMF with separate thermal treatment upon the FBG and LMF, respectively. Finally, we presented a selection criterion for the minimum unpumped doped fiber length inside the LMF with experimental verification.

  7. Monolithic Composite “Pressure + Acceleration + Temperature + Infrared” Sensor Using a Versatile Single-Sided “SiN/Poly-Si/Al” Process-Module

    Science.gov (United States)

    Ni, Zao; Yang, Chen; Xu, Dehui; Zhou, Hong; Zhou, Wei; Li, Tie; Xiong, Bin; Li, Xinxin

    2013-01-01

    We report a newly developed design/fabrication module with low-cost single-sided “low-stress-silicon-nitride (LS-SiN)/polysilicon (poly-Si)/Al” process for monolithic integration of composite sensors for sensing-network-node applications. A front-side surface-/bulk-micromachining process on a conventional Si-substrate is developed, featuring a multifunctional SiN/poly-Si/Al layer design for diverse sensing functions. The first “pressure + acceleration + temperature + infrared” (PATIR) composite sensor with the chip size of 2.5 mm × 2.5 mm is demonstrated. Systematic theoretical design and analysis methods are developed. The diverse sensing components include a piezoresistive absolute-pressure sensor (up to 700 kPa, with a sensitivity of 49 mV/MPa under 3.3 V supplied voltage), a piezoresistive accelerometer (±10 g, with a sensitivity of 66 μV/g under 3.3 V and a −3 dB bandwidth of 780 Hz), a thermoelectric infrared detector (with a responsivity of 45 V/W and detectivity of 3.6 × 107 cm·Hz1/2/W) and a thermistor (−25–120 °C). This design/fabrication module concept enables a low-cost monolithically-integrated “multifunctional-library” technique. It can be utilized as a customizable tool for versatile application-specific requirements, which is very useful for small-size, low-cost, large-scale sensing-network node developments. PMID:23325169

  8. Monolithic Composite “Pressure + Acceleration + Temperature + Infrared” Sensor Using a Versatile Single-Sided “SiN/Poly-Si/Al” Process-Module

    Directory of Open Access Journals (Sweden)

    Xinxin Li

    2013-01-01

    Full Text Available We report a newly developed design/fabrication module with low-cost single-sided “low-stress-silicon-nitride (LS-SiN/polysilicon (poly-Si/Al” process for monolithic integration of composite sensors for sensing-network-node applications. A front-side surface-/bulk-micromachining process on a conventional Si-substrate is developed, featuring a multifunctional SiN/poly-Si/Al layer design for diverse sensing functions. The first “pressure + acceleration + temperature + infrared” (PATIR composite sensor with the chip size of 2.5 mm × 2.5 mm is demonstrated. Systematic theoretical design and analysis methods are developed. The diverse sensing components include a piezoresistive absolute-pressure sensor (up to 700 kPa, with a sensitivity of 49 mV/MPa under 3.3 V supplied voltage, a piezoresistive accelerometer (±10 g, with a sensitivity of 66 μV/g under 3.3 V and a −3 dB bandwidth of 780 Hz, a thermoelectric infrared detector (with a responsivity of 45 V/W and detectivity of 3.6 × 107 cm·Hz1/2/W and a thermistor (−25–120 °C. This design/fabrication module concept enables a low-cost monolithically-integrated “multifunctional-library” technique. It can be utilized as a customizable tool for versatile application-specific requirements, which is very useful for small-size, low-cost, large-scale sensing-network node developments.

  9. The APSEL4D Monolithic Active Pixel Sensor and its Usage in a Single Electron Interference Experiment

    CERN Document Server

    Alberghi, Gian Luigi

    We have realized a Data Acquisition chain for the use and characterization of APSEL4D, a 32 x 128 Monolithic Active Pixel Sensor, developed as a prototype for frontier experiments in high energy particle physics. In particular a transition board was realized for the conversion between the chip and the FPGA voltage levels and for the signal quality enhancing. A Xilinx Spartan-3 FPGA was used for real time data processing, for the chip control and the communication with a Personal Computer through a 2.0 USB port. For this purpose a firmware code, developed in VHDL language, was written. Finally a Graphical User Interface for the online system monitoring, hit display and chip control, based on windows and widgets, was realized developing a C++ code and using Qt and Qwt dedicated libraries. APSEL4D and the full acquisition chain were characterized for the first time with the electron beam of the transmission electron microscope and with 55Fe and 90Sr radioactive sources. In addition, a beam test was performed at ...

  10. 1.25  GHz sine wave gating InGaAs/InP single-photon detector with a monolithically integrated readout circuit.

    Science.gov (United States)

    Jiang, Wen-Hao; Liu, Jian-Hong; Liu, Yin; Jin, Ge; Zhang, Jun; Pan, Jian-Wei

    2017-12-15

    InGaAs/InP single-photon detectors (SPDs) are the key devices for applications requiring near-infrared single-photon detection. The gating mode is an effective approach to synchronous single-photon detection. Increasing gating frequency and reducing the module size are important challenges for the design of such a detector system. Here we present for the first time, to the best of our knowledge, an InGaAs/InP SPD with 1.25 GHz sine wave gating (SWG) using a monolithically integrated readout circuit (MIRC). The MIRC has a size of 15  mm×15  mm and implements the miniaturization of avalanche extraction for high-frequency SWG. In the MIRC, low-pass filters and a low-noise radio frequency amplifier are integrated based on the technique of low temperature co-fired ceramic, which can effectively reduce the parasitic capacitance and extract weak avalanche signals. We then characterize the InGaAs/InP SPD to verify the functionality and reliability of the MIRC, and the SPD exhibits excellent performance with 27.5% photon detection efficiency, a 1.2 kcps dark count rate, and 9.1% afterpulse probability at 223 K and 100 ns hold-off time. With this MIRC, one can further design miniaturized high-frequency SPD modules that are highly required for practical applications.

  11. Porous polymer monolithic col

    Directory of Open Access Journals (Sweden)

    Lydia Terborg

    2015-05-01

    Full Text Available A new approach has been developed for the preparation of mixed-mode stationary phases to separate proteins. The pore surface of monolithic poly(glycidyl methacrylate-co-ethylene dimethacrylate capillary columns was functionalized with thiols and coated with gold nanoparticles. The final mixed mode surface chemistry was formed by attaching, in a single step, alkanethiols, mercaptoalkanoic acids, and their mixtures on the free surface of attached gold nanoparticles. Use of these mixtures allowed fine tuning of the hydrophobic/hydrophilic balance. The amount of attached gold nanoparticles according to thermal gravimetric analysis was 44.8 wt.%. This value together with results of frontal elution enabled calculation of surface coverage with the alkanethiol and mercaptoalkanoic acid ligands. Interestingly, alkanethiols coverage in a range of 4.46–4.51 molecules/nm2 significantly exceeded that of mercaptoalkanoic acids with 2.39–2.45 molecules/nm2. The mixed mode character of these monolithic stationary phases was for the first time demonstrated in the separations of proteins that could be achieved in the same column using gradient elution conditions typical of reverse phase (using gradient of acetonitrile in water and ion exchange chromatographic modes (applying gradient of salt in water, respectively.

  12. Monolithic exploding foil initiator

    Science.gov (United States)

    Welle, Eric J; Vianco, Paul T; Headley, Paul S; Jarrell, Jason A; Garrity, J. Emmett; Shelton, Keegan P; Marley, Stephen K

    2012-10-23

    A monolithic exploding foil initiator (EFI) or slapper detonator and the method for making the monolithic EFI wherein the exploding bridge and the dielectric from which the flyer will be generated are integrated directly onto the header. In some embodiments, the barrel is directly integrated directly onto the header.

  13. A monolithic white laser.

    Science.gov (United States)

    Fan, Fan; Turkdogan, Sunay; Liu, Zhicheng; Shelhammer, David; Ning, C Z

    2015-09-01

    Monolithic semiconductor lasers capable of emitting over the full visible-colour spectrum have a wide range of important applications, such as solid-state lighting, full-colour displays, visible colour communications and multi-colour fluorescence sensing. The ultimate form of such a light source would be a monolithic white laser. However, realizing such a device has been challenging because of intrinsic difficulties in achieving epitaxial growth of the mismatched materials required for different colour emission. Here, we demonstrate a monolithic multi-segment semiconductor nanosheet based on a quaternary alloy of ZnCdSSe that simultaneously lases in the red, green and blue. This is made possible by a novel nanomaterial growth strategy that enables separate control of the composition, morphology and therefore bandgaps of the segments. Our nanolaser can be dynamically tuned to emit over the full visible-colour range, covering 70% more perceptible colours than the most commonly used illuminants.

  14. Neonatal cholestasis - Single centre experience in Central India

    Directory of Open Access Journals (Sweden)

    Mayank Jain

    2016-01-01

    Full Text Available Background: Neonatal cholestasis syndrome (NCS is a major cause of morbidity and mortality in infants. The disorder has rarely been studied in centers from Central India. Objectives: To study the prevalence, clinical presentation and etiology of NCS at a tertiary referral center in Central India. Materials and Methods: The study was carried out at a tertiary referral center in Central India. The study is a descriptive study. The records of all patients with suspected NCS treated in the Department of Pediatrics from 2007−2012 were analyzed. Results: One hundred and sixty-eight children had a provisional diagnosis of NCS. The complete records of 100 children were available for the study. The median age of presentation was 78 days (range 15−270 days. The male: female ratio was 1.17:1. The clinical features noted were- jaundice (100/100,100%, failure to thrive (73,73%, organomegaly (68, 68%, acholic stools (38,38%, abdominal distention (52,52% and poor feeding (29, 29%. The etiology as confirmed by investigations is as follows- neonatal hepatitis (20,20%, idiopathic neonatal hepatitis (18,18%, biliary atresia (41,41%, sepsis (14,14% and others (7,7%. Conclusions: The proportion of NCS in our group of patients was 1.2 per 1000 patients. Jaundice, organomegaly and failure to thrive are the common presentations. Biliary atresia, neonatal hepatitis and idiopathic neonatal hepatitis were the common etiological factors at our center.

  15. Neonatal Cholestasis - Single Centre Experience in Central India.

    Science.gov (United States)

    Jain, Mayank; Adkar, Sagar; Waghmare, Chandrashekhar; Jain, Jenisha; Jain, Shikhar; Jain, Kamna; Passi, Gouri Rao; Vinay, Rashmi Shad; Soni, M K

    2016-01-01

    Neonatal cholestasis syndrome (NCS) is a major cause of morbidity and mortality in infants. The disorder has rarely been studied in centers from Central India. To study the prevalence, clinical presentation and etiology of NCS at a tertiary referral center in Central India. The study was carried out at a tertiary referral center in Central India. The study is a descriptive study. The records of all patients with suspected NCS treated in the Department of Pediatrics from 2007-2012 were analyzed. One hundred and sixty-eight children had a provisional diagnosis of NCS. The complete records of 100 children were available for the study. The median age of presentation was 78 days (range 15-270 days). The male: female ratio was 1.17:1. The clinical features noted were- jaundice (100/100,100%), failure to thrive (73,73%), organomegaly (68, 68%), acholic stools (38,38%), abdominal distention (52,52%) and poor feeding (29, 29%). The etiology as confirmed by investigations is as follows- neonatal hepatitis (20,20%), idiopathic neonatal hepatitis (18,18%), biliary atresia (41,41%), sepsis (14,14%) and others (7,7%). The proportion of NCS in our group of patients was 1.2 per 1000 patients. Jaundice, organomegaly and failure to thrive are the common presentations. Biliary atresia, neonatal hepatitis and idiopathic neonatal hepatitis were the common etiological factors at our center.

  16. Electrical and functional characterisation with single chips and module prototypes of the 1.2 Gb/s serial data link of the monolithic active pixel sensor for the upgrade of the ALICE Inner Tracking System

    CERN Document Server

    Bonora, Matthias; Aglieri Rinella, Gianluca; Hillemanns, Hartmut; Kim, Daehyeok; Kugathasan, Thanushan; Lattuca, Alessandra; Mazza, Giovanni; Sielewicz, Krzysztof Marek; Snoeys, Walter

    2017-01-01

    The upgrade of the ALICE Inner Tracking System uses a newly developed monolithic active pixel sensor (ALPIDE) which will populate seven tracking layers surrounding the interaction point. Chips communicate with the readout electronics using a 1.2 Gb/s data link and a 40 Mb/s bidirectional control link. Event data are transmitted to the readout electronics over microstrips on a Flexible Printed Circuit and a 6 m long twinaxial cable. This paper outlines the characterisation effort for assessing the Data Transmission Unit performance of single sensors and prototypes of the detector modules. It describes the different prototypes used, the test system and procedures, and results of laboratory and irradiation tests.

  17. Embedded-monolith armor

    Science.gov (United States)

    McElfresh, Michael W.; Groves, Scott E; Moffet, Mitchell L.; Martin, Louis P.

    2016-07-19

    A lightweight armor system utilizing a face section having a multiplicity of monoliths embedded in a matrix supported on low density foam. The face section is supported with a strong stiff backing plate. The backing plate is mounted on a spall plate.

  18. Towards a Technique for Extracting Microservices from Monolithic Enterprise Systems

    OpenAIRE

    Levcovitz, Alessandra; Terra, Ricardo; Valente, Marco Tulio

    2016-01-01

    The idea behind microservices architecture is to develop a single large, complex application as a suite of small, cohesive, independent services. On the other way, monolithic systems get larger over the time, deviating from the intended architecture, and becoming risky and expensive to evolve. This paper describes a technique to identify and define microservices on monolithic enterprise systems. As the major contribution, our evaluation shows that our approach was able to identify relevant ca...

  19. Monolithic cells for solar fuels.

    Science.gov (United States)

    Rongé, Jan; Bosserez, Tom; Martel, David; Nervi, Carlo; Boarino, Luca; Taulelle, Francis; Decher, Gero; Bordiga, Silvia; Martens, Johan A

    2014-12-07

    Hybrid energy generation models based on a variety of alternative energy supply technologies are considered the best way to cope with the depletion of fossil energy resources and to limit global warming. One of the currently missing technologies is the mimic of natural photosynthesis to convert carbon dioxide and water into chemical fuel using sunlight. This idea has been around for decades, but artificial photosynthesis of organic molecules is still far away from providing real-world solutions. The scientific challenge is to perform in an efficient way the multi-electron transfer reactions of water oxidation and carbon dioxide reduction using holes and single electrons generated in an illuminated semiconductor. In this tutorial review the design of photoelectrochemical (PEC) cells that combine solar water oxidation and CO2 reduction is discussed. In such PEC cells simultaneous transport and efficient use of light, electrons, protons and molecules has to be managed. It is explained how efficiency can be gained by compartmentalisation of the water oxidation and CO2 reduction processes by proton exchange membranes, and monolithic concepts of artificial leaves and solar membranes are presented. Besides transferring protons from the anode to the cathode compartment the membrane serves as a molecular barrier material to prevent cross-over of oxygen and fuel molecules. Innovative nano-organized multimaterials will be needed to realise practical artificial photosynthesis devices. This review provides an overview of synthesis techniques which could be used to realise monolithic multifunctional membrane-electrode assemblies, such as Layer-by-Layer (LbL) deposition, Atomic Layer Deposition (ALD), and porous silicon (porSi) engineering. Advances in modelling approaches, electrochemical techniques and in situ spectroscopies to characterise overall PEC cell performance are discussed.

  20. Central dogma at the single-molecule level in living cells.

    Science.gov (United States)

    Li, Gene-Wei; Xie, X Sunney

    2011-07-20

    Gene expression originates from individual DNA molecules within living cells. Like many single-molecule processes, gene expression and regulation are stochastic, that is, sporadic in time. This leads to heterogeneity in the messenger-RNA and protein copy numbers in a population of cells with identical genomes. With advanced single-cell fluorescence microscopy, it is now possible to quantify transcriptomes and proteomes with single-molecule sensitivity. Dynamic processes such as transcription-factor binding, transcription and translation can be monitored in real time, providing quantitative descriptions of the central dogma of molecular biology and the demonstration that a stochastic single-molecule event can determine the phenotype of a cell.

  1. Bioaffinity chromatography on monolithic supports

    NARCIS (Netherlands)

    Tetala, K.K.R.; Beek, van T.A.

    2010-01-01

    Affinity chromatography on monolithic supports is a powerful analytical chemical platform because it allows for fast analyses, small sample volumes, strong enrichment of trace biomarkers and applications in microchips. In this review, the recent research using monolithic materials in the field of

  2. Characterization of SOI monolithic detector system

    Science.gov (United States)

    Álvarez-Rengifo, P. L.; Soung Yee, L.; Martin, E.; Cortina, E.; Ferrer, C.

    2013-12-01

    A monolithic active pixel sensor for charged particle tracking was developed. This research is performed within the framework of an R&D project called TRAPPISTe (Tracking Particles for Physics Instrumentation in SOI Technology) whose aim is to evaluate the feasibility of developing a Monolithic Active Pixel Sensor (MAPS) with Silicon-on-Insulator (SOI) technology. Two chips were fabricated: TRAPPISTe-1 and TRAPPISTe-2. TRAPPISTe-1 was produced at the WINFAB facility at the Université catholique de Louvain (UCL), Belgium, in a 2 μm fully depleted (FD-SOI) CMOS process. TRAPPISTe-2 was fabricated with the LAPIS 0.2 μm FD-SOI CMOS process. The electrical characterization on single transistor test structures and of the electronic readout for the TRAPPISTe series of monolithic pixel detectors was carried out. The behavior of the prototypes’ electronics as a function of the back voltage was studied. Results showed that both readout circuits exhibited sensitivity to the back voltage. Despite this unwanted secondary effect, the responses of TRAPPISTe-2 amplifiers can be improved by a variation in the circuit parameters.

  3. Electrically driven monolithic subwavelength plasmonic interconnect circuits.

    Science.gov (United States)

    Liu, Yang; Zhang, Jiasen; Liu, Huaping; Wang, Sheng; Peng, Lian-Mao

    2017-10-01

    In the post-Moore era, an electrically driven monolithic optoelectronic integrated circuit (OEIC) fabricated from a single material is pursued globally to enable the construction of wafer-scale compact computing systems with powerful processing capabilities and low-power consumption. We report a monolithic plasmonic interconnect circuit (PIC) consisting of a photovoltaic (PV) cascading detector, Au-strip waveguides, and electrically driven surface plasmon polariton (SPP) sources. These components are fabricated from carbon nanotubes (CNTs) via a CMOS (complementary metal-oxide semiconductor)-compatible doping-free technique in the same feature size, which can be reduced to deep-subwavelength scale (~λ/7 to λ/95, λ = 1340 nm) compared with the 14-nm technique node. An OEIC could potentially be configured as a repeater for data transport because of its "photovoltaic" operation mode to transform SPP energy directly into electricity to drive subsequent electronic circuits. Moreover, chip-scale throughput capability has also been demonstrated by fabricating a 20 × 20 PIC array on a 10 mm × 10 mm wafer. Tailoring photonics for monolithic integration with electronics beyond the diffraction limit opens a new era of chip-level nanoscale electronic-photonic systems, introducing a new path to innovate toward much faster, smaller, and cheaper computing frameworks.

  4. Safety characteristics of the monolithic CFC divertor

    International Nuclear Information System (INIS)

    Zucchetti, M.; Merola, M.; Matera, R.

    1994-01-01

    The main distinguishing feature of the monolithic CFC divertor is the use of a single material, a carbon fibre reinforced carbon, for the protective armour, the heat sink and the cooling channels. This removes joint interface problems which are one of the most important concerns related to the reference solutions of the ITER CDA divertor. An activation analysis of the different coolant options for this concept is presented. It turns out that neither short-term nor long-term activation are a concern for any coolants investigated. Therefore the proposed concept proves to be attractive from a safety stand-point also. ((orig.))

  5. Safety characteristics of the monolithic CFC divertor

    Science.gov (United States)

    Zucchetti, M.; Merola, M.; Matera, R.

    1994-09-01

    The main distinguishing feature of the monolithic CFC divertor is the use of a single material, a carbon fibre reinforced carbon, for the protective armour, the heat sink and the cooling channels. This removes joint interface problems which are one of the most important concerns related to the reference solutions of the ITER CDA divertor. An activation analysis of the different coolant options for this concept is presented. It turns out that neither short-term nor long-term activation are a concern for any coolants investigated. Therefore the proposed concept proves to be attractive from a safety stand-point also.

  6. Single- and central-diffractive production of open charm and bottom mesons at the LHC

    CERN Document Server

    Łuszczak, Marta; Szczurek, Antoni

    2015-01-01

    We discuss diffractive production of open charm and bottom mesons at the LHC. The differential cross sections for single- and central-diffractive mechanisms for $c\\bar c$ and $b\\bar b$ pair production are calculated in the framework of the Ingelman-Schlein model corrected for absorption effects. The LO gluon-gluon fusion and quark-antiquark anihilation partonic subprocesses are taken into consideration, which are calculated within standard collinear approximation. The extra corrections from reggeon exchanges are taken into account. The hadronization of charm and bottom quarks is taken into account by means of fragmentation functions. Predictions for single- and central-diffractive production in the case of $D$ and $B$ mesons, as well as $D\\bar D$ pairs are presented, including detector acceptance of the ATLAS, CMS and LHCb Collaborations.

  7. Large volume monolithic stationary phases: preparation, properties, and applications.

    Science.gov (United States)

    Podgornik, Aleš; Jančar, Janez; Mihelič, Igor; Barut, Miloš; Strancar, Aleš

    2010-03-01

    Monoliths represents the 4th generation of chromatographic supports. They consist of a single piece of highly porous material with interconnected flow through pores. Because of that transport is based on convection what results in a flow unaffected separation and dynamic binding capacity. This is especially important when large molecular weight molecules such as proteins, DNA or viruses have to be purified. For this purpose large volume monolithic columns are needed. In this article preparation of such columns is described together with their main applications. The article is dedicated to Prof. Tine Koloini who substantially contributed to this topic.

  8. Estimation of methacrylate monolith binding capacity from pressure drop data.

    Science.gov (United States)

    Podgornik, Aleš; Smrekar, Vida; Krajnc, Peter; Strancar, Aleš

    2013-01-11

    Convective chromatographic media comprising of membranes and monoliths represent an important group of chromatographic supports due to their flow-unaffected chromatographic properties and consequently fast separation and purification even of large biological macromolecules. Consisting of a single piece of material, common characterization procedures based on analysis of a small sample assuming to be representative for the entire batch, cannot be applied. Because of that, non-invasive characterization methods are preferred. In this work pressure drop was investigated for an estimation of dynamic binding capacity (DBC) of proteins and plasmid DNA for monoliths with different pore sizes. It was demonstrated that methacrylate monolith surface area is reciprocally proportional to pore diameter and that pressure drop on monolith is reciprocally proportional to square pore size demonstrating that methacrylate monolith microstructure is preserved by changing pore size. Based on these facts mathematical formalism has been derived predicting that DBC is in linear correlation with the square root of pressure drop. This was experimentally confirmed for ion-exchange and hydrophobic interactions for proteins and plasmid DNA. Furthermore, pressure drop was also applied for an estimation of DBC in grafted layers of different thicknesses as estimated from the pressure drop data. It was demonstrated that the capacity is proportional to the estimated grafted layer thickness. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Monolithic metal oxide transistors.

    Science.gov (United States)

    Choi, Yongsuk; Park, Won-Yeong; Kang, Moon Sung; Yi, Gi-Ra; Lee, Jun-Young; Kim, Yong-Hoon; Cho, Jeong Ho

    2015-04-28

    We devised a simple transparent metal oxide thin film transistor architecture composed of only two component materials, an amorphous metal oxide and ion gel gate dielectric, which could be entirely assembled using room-temperature processes on a plastic substrate. The geometry cleverly takes advantage of the unique characteristics of the two components. An oxide layer is metallized upon exposure to plasma, leading to the formation of a monolithic source-channel-drain oxide layer, and the ion gel gate dielectric is used to gate the transistor channel effectively at low voltages through a coplanar gate. We confirmed that the method is generally applicable to a variety of sol-gel-processed amorphous metal oxides, including indium oxide, indium zinc oxide, and indium gallium zinc oxide. An inverter NOT logic device was assembled using the resulting devices as a proof of concept demonstration of the applicability of the devices to logic circuits. The favorable characteristics of these devices, including (i) the simplicity of the device structure with only two components, (ii) the benign fabrication processes at room temperature, (iii) the low-voltage operation under 2 V, and (iv) the excellent and stable electrical performances, together support the application of these devices to low-cost portable gadgets, i.e., cheap electronics.

  10. Mortality following single-fraction stereotactic body radiation therapy for central pulmonary oligometastasis.

    Science.gov (United States)

    Ma, Sung Jun; Mix, Michael; Rivers, Charlotte; Hennon, Mark; Gomez, Jorge; Singh, Anurag K

    2017-01-01

    The case of a 56-year-old male who developed bronchopulmonary hemorrhage after a course of stereotactic body radiation therapy (SBRT) for centrally located squamous cell lung carcinoma is presented. The patient was previously treated with concurrent chemoradiation for stage IVA squamous cell carcinoma of the base of tongue. He showed no evidence of disease for 4 years until he developed a solitary metastasis of squamous cell carcinoma in the right hilum. He underwent a single fraction of 26 Gy with heterogeneity correction. He showed no evidence of disease for 13 months until he developed a sudden grade 4 bronchopulmonary hemorrhage. He underwent an urgent right pneumonectomy and later died of a post-operative complication. Pathologic analysis of the specimen revealed no evidence of tumor. Single-fraction SBRT of 26 Gy was sufficient to achieve complete response of his large central lung tumor. However, when treating patients with central lung tumors, some risk of mortality may be unavoidable with either SBRT or pneumonectomy.

  11. Growth techniques for monolithic YBCO solenoidal magnets

    International Nuclear Information System (INIS)

    Scruggs, S.J.; Putman, P.T.; Fang, H.; Alessandrini, M.; Salama, K.

    2006-01-01

    The possibility of growing large single domain YBCO solenoids by the use of a large seed has been investigated. There are two known methods for producing a similar solenoid. This first is a conventional top seeded melt growth process followed by a post processing machining step to create the bore. The second involves using multiple seeds spaced around the magnet bore. The appeal of the new technique lies in decreasing processing time compared to the single seed technique, while avoiding alignment problems found in the multiple seeding technique. By avoiding these problems, larger diameter monoliths can be produced. Large diameter monoliths are beneficial because the maximum magnetic field produced by a trapped field magnet is proportional to the radius of the sample. Furthermore, the availability of trapped field magnets with large diameter could enable their use in applications that traditionally have been considered to require wound electromagnets, such as beam bending magnets for particle accelerators or electric propulsion. A comparison of YBCO solenoids grown by the use of a large seed and grown by the use of two small seeds simulating multiple seeding is made. Trapped field measurements as well as microstructure evaluation were used in characterization of each solenoid. Results indicate that high quality growth occurs only in the vicinity of the seeds for the multiple seeded sample, while the sample with the large seeded exhibited high quality growth throughout the entire sample

  12. Nebivolol reduces central blood pressure in stage I hypertensive patients: experimental single cohort study

    Directory of Open Access Journals (Sweden)

    Renan Oliveira Vaz-de-Melo

    Full Text Available CONTEXT AND OBJECTIVES: Assessment of central blood pressure (BP has grown substantially over recent years because evidence has shown that central BP is more relevant to cardiovascular outcomes than peripheral BP. Thus, different classes of antihypertensive drugs have different effects on central BP despite similar reductions in brachial BP. The aim of this study was to investigate the effect of nebivolol, a β-blocker with vasodilator properties, on the biochemical and hemodynamic parameters of hypertensive patients.DESIGN AND SETTING: Experimental single cohort study conducted in the outpatient clinic of a university hospital.METHODS: Twenty-six patients were recruited. All of them underwent biochemical and hemodynamic evaluation (BP, heart rate (HR, central BP and augmentation index before and after 3 months of using nebivolol.RESULTS: 88.5% of the patients were male; their mean age was 49.7 ± 9.3 years and most of them were overweight (29.6 ± 3.1 kg/m2 with large abdominal waist (102.1 ± 7.2 cm. There were significant decreases in peripheral systolic BP (P = 0.0020, diastolic BP (P = 0.0049, HR (P < 0.0001 and central BP (129.9 ± 12.3 versus 122.3 ± 10.3 mmHg; P = 0.0083 after treatment, in comparison with the baseline values. There was no statistical difference in the augmentation index or in the biochemical parameters, from before to after the treatment.CONCLUSIONS: Nebivolol use seems to be associated with significant reduction of central BP in stage I hypertensive patients, in addition to reductions in brachial systolic and diastolic BP.

  13. Development of double chain phosphatidylcholine functionalized polymeric monoliths for immobilized artificial membrane chromatography.

    Science.gov (United States)

    Wang, Qiqin; Peng, Kun; Chen, Weijia; Cao, Zhen; Zhu, Peijie; Zhao, Yumei; Wang, Yuqiang; Zhou, Haibo; Jiang, Zhengjin

    2017-01-06

    This study described a simple synthetic methodology for preparing biomembrane mimicking monolithic column. The suggested approach not only simplifies the preparation procedure but also improves the stability of double chain phosphatidylcholine (PC) functionalized monolithic column. The physicochemical properties of the optimized monolithic column were characterized by scanning electron microscopy, energy-dispersive X-ray spectrometry, and nano-LC. Satisfactory column permeability, efficiency, stability and reproducibility were obtained on this double chain PC functionalized monolithic column. It is worth noting that the resulting polymeric monolith exhibits great potential as a useful alternative of commercial immobilized artificial membrane (IAM) columns for in vitro predication of drug-membrane interactions. Furthermore, the comparative study of both double chain and single chain PC functionalized monoliths indicates that the presence or absence of glycerol backbone and the number of acyl chains are not decisive for the predictive ability of IAM monoliths on drug-membrane interactions. This novel PC functionalized monolithic column also exhibited good selectivity for a protein mixture and a set of pharmaceutical compounds. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Acoustic of monolithic dome structures

    Directory of Open Access Journals (Sweden)

    Mostafa Refat Ismail

    2018-03-01

    The interior of monolithic domes have perfect, concave shapes to ensure that sound travels through the dome and perfectly collected at different vocal points. These dome structures are utilized for domestic use because the scale allows the focal points to be positioned across daily life activities, thereby affecting the sonic comfort of the internal space. This study examines the various acoustic treatments and parametric configurations of monolithic dome sizes. A geometric relationship of acoustic treatment and dome radius is established to provide architects guidelines on the correct selection of absorption needed to maintain the acoustic comfort of these special spaces.

  15. Monolithic fiber optic sensor assembly

    Science.gov (United States)

    Sanders, Scott

    2015-02-10

    A remote sensor element for spectrographic measurements employs a monolithic assembly of one or two fiber optics to two optical elements separated by a supporting structure to allow the flow of gases or particulates therebetween. In a preferred embodiment, the sensor element components are fused ceramic to resist high temperatures and failure from large temperature changes.

  16. UV-LED photopolymerised monoliths

    Czech Academy of Sciences Publication Activity Database

    Abele, S.; Nie, F.; Foret, František; Paull, B.; Macka, M.

    2008-01-01

    Roč. 133, č. 7 (2008), s. 864-866 ISSN 0003-2654 R&D Projects: GA AV ČR KAN400310651 Institutional research plan: CEZ:AV0Z40310501 Keywords : photopolymerisation * UV-LED * polymethacrylate monolith Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.761, year: 2008

  17. Design of Semiconductor-Based Back Reflectors for High Voc Monolithic Multijunction Solar Cells: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, I.; Geisz, J.; Steiner, M.; Olson, J.; Friedman, D.; Kurtz, S.

    2012-06-01

    State-of-the-art multijunction cell designs have the potential for significant improvement before going to higher number of junctions. For example, the Voc can be substantially increased if the photon recycling taking place in the junctions is enhanced. This has already been demonstrated (by Alta Devices) for a GaAs single-junction cell. For this, the loss of re-emitted photons by absorption in the underlying layers or substrate must be minimized. Selective back surface reflectors are needed for this purpose. In this work, different architectures of semiconductor distributed Bragg reflectors (DBR) are assessed as the appropriate choice for application in monolithic multijunction solar cells. Since the photon re-emission in the photon recycling process is spatially isotropic, the effect of the incident angle on the reflectance spectrum is of central importance. In addition, the DBR structure must be designed taking into account its integration into the monolithic multijunction solar cells, concerning series resistance, growth economics, and other issues. We analyze the tradeoffs in DBR design complexity with all these requirements to determine if such a reflector is suitable to improve multijunction solar cells.

  18. Monolithic bed structure for capillary liquid chromatography.

    Science.gov (United States)

    Aggarwal, Pankaj; Tolley, H Dennis; Lee, Milton L

    2012-01-06

    Monolithic stationary phases show promise for LC as a result of their good permeability, ease of preparation and broad selectivity. Inorganic silica monoliths have been extensively studied and applied for separation of small molecules. The presence of a large number of through pores and small skeletal structure allows the chromatographic efficiencies of silica monoliths to be comparable to columns packed with 5 μm silica particles, at much lower back pressure. In comparison, organic polymeric monoliths have been mostly used for separation of bio-molecules; however, recently, applications are expanding to small molecules as well. Organic monoliths with high surface areas and fused morphology rather than conventional globular morphology have shown good performance for small molecule separations. Factors such as domain size, through-pore size and mesopore size of the monolithic structures have been found to govern the efficiency of monolithic columns. The structure and performance of monolithic columns are reviewed in comparison to particle packed columns. Studying and characterizing the bed structures of organic monolithic columns can provide great insights into their performance, and aid in structure-directed synthesis of new and improved monoliths. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. Characterization of a Messer – The late-Medieval single-edged sword of Central Europe

    Energy Technology Data Exchange (ETDEWEB)

    Fajfar, Peter; Medved, Jožef; Klančnik, Grega [Department of Materials and Metallurgy, Faculty of Natural Sciences and Engineering, University of Ljubljana, Aškerčeva cesta 12, SI-1000 Ljubljana (Slovenia); Lazar, Tomaž [National Museum of Slovenia, Prešernova cesta 20, SI-1000 Ljubljana (Slovenia); Nečemer, Marijan [Jožef Stefan Institut, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Mrvar, Primož, E-mail: primoz.mrvar@omm.ntf.uni-lj.si [Department of Materials and Metallurgy, Faculty of Natural Sciences and Engineering, University of Ljubljana, Aškerčeva cesta 12, SI-1000 Ljubljana (Slovenia)

    2013-12-15

    Metallurgical characterization of a sword blade fragments dating from the second half of the 15th century found in central Slovenia was performed in order to determine its chemical composition, microstructure, microhardness, and to obtain insight into the methods of manufacture of a late-medieval Messer sword. As the artefact was broken, examinations were limited to six very small fragments that were allowed to be removed from the cutting edge, core and the back of the blade. Light optical microscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy, energy dispersive X-ray fluorescence spectrometry, differential scanning calorimetry, thermodynamics approach and Vickers micro-hardness tests were employed to analyze the microstructure and mechanical properties. The results show that the sword was manufactured from a single wrought iron billet. The surface of the sword was carburized. No evidence of quenching was found. The ferritic microstructure is concentrated in the core, and the pearlitic in the outer layer of the blade. All metal fragments contained non-metallic inclusions that were derived mostly from slag and some from hammer scale. - Highlights: • A metallurgical characterization of a medieval sword blade has been performed. • The carbon content decreased from the surface to the core of the blade. • The dominant microstructure in the outer layer is pearlite and in the core is ferrite. • The presence of lump shaped and elongated non-metallic inclusions was observed. • The sword was manufactured from a single wrought iron billet.

  20. Optical access network using centralized light source, single-mode fiber + broad wavelength window multimode fiber

    Science.gov (United States)

    Yam, Scott S.-H.; Kim, Jaedon; Gutierrez, David; Achten, Frank

    2006-08-01

    Access networks based on a single-mode fiber (SMF) using a centralized light source (CLS) have attracted much attention recently due to their wavelength management flexibility and potential for cost reduction at customers' premises. Future networks, in addition, are likely to contain segments of multimode fiber (MMF), whose core dimension is relatively large in comparison with its single-mode counterpart, substantially reducing fiber alignment constraints and the subsequent network construction and installation cost. In this study, a CLS-based passive optical network (PON) is proposed, which will use a new generation of high-performance MMF optimized for a broad wavelength transmission window spanning from 1300to1550 nm, with a bandwidth distance product (BDP) of 40 Gbit/s-km. The proposed architecture is implemented in a test bed, and its performance is verified by bit error ratio (BER) measurement. Results show that we can implement high-performance CLS-based PONs containing both an SMF and an MMF infrastructure, simultaneously.

  1. Monolithic pattern-sensitive detector

    Science.gov (United States)

    Berger, Kurt W.

    2000-01-01

    Extreme ultraviolet light (EUV) is detected using a precisely defined reference pattern formed over a shallow junction photodiode. The reference pattern is formed in an EUV absorber preferably comprising nickel or other material having EUV- and other spectral region attenuating characteristics. An EUV-transmissive energy filter is disposed between a passivation oxide layer of the photodiode and the EUV transmissive energy filter. The device is monolithically formed to provide robustness and compactness.

  2. Aluminophosphate monoliths with high CO2-over-N2 selectivity and CO2 capture capacity

    OpenAIRE

    Akhtar, Farid; Keshavarzi, Neda; Shakarova, Dilshod; Cheung, Ocean; Hedin, Niklas; Bergström, Lennart

    2014-01-01

    Monoliths of microporous aluminophosphates (AlPO4-17 and AlPO4-53) were structured by binder-freepulsed current processing. Such monoliths could be important for carbon capture from flue gas. TheAlPO4-17 and AlPO4-53 monoliths exhibited a tensile strength of 1.0 MPa and a CO2 adsorption capacityof 2.5 mmol g1 and 1.6 mmol g1, respectively at 101 kPa and 0 C. Analyses of single component CO2and N2 adsorption data indicated that the AlPO4-53 monoliths had an extraordinarily high CO2-over-N2sele...

  3. PERIPHERALLY INSERTED CENTRAL VENOUS CATHETER SAFETYIN BURN CARE: A SINGLE CENTRE RETROSPECTIVE COHORT REVIEW

    Science.gov (United States)

    Austin, Ryan E.; Shahrokhi, Shahriar; Bolourani, Siavash; Jeschke, Marc G.

    2014-01-01

    Objective PICC line use for central venous access in thermally injured patients has increased in recent years despite a lack of evidence regarding safety in this patient population. A recent survey of invasive catheter practices among 44 burn centers in the United States found that 37% of burn units use PICC lines as part of their treatment protocol. The goal of this study was to compare PICC associated complication rates to existing literature in both the critical care and burn settings. Methods A single institution retrospective cohort review of patients who received a PICC line during admission to a regional burn unit between 2008–2013. Fifty-three patients were identified with a total of seventy-three PICC lines. The primary outcome measurement for this study was indication for PICC line discontinuation. Results The most common reason for PICC line discontinuation was that the line was no longer indicated (45.2%). Four cases of symptomatic upper extremity deep vein thrombosis (5.5%) and 3 cases of central line associated bloodstream infection (4.3%, 2.72 infections per 1000 line days) were identified. PICC lines were in situ an average of 15 days [range 1–49 days]. Conclusions We suggest that PICC line associated complication rates are similar to those published in the critical care literature. Though these rates are higher than those published in the burn literature, they are similar to CVC associated complication rates. While PICC lines can be a useful resource in the treatment of the thermally injured patient, they are associated with significant, and potentially fatal risks. PMID:25501778

  4. Monoliths from poly(ethylene glycol) diacrylate and dimethacrylate for capillary hydrophobic interaction chromatography of proteins.

    Science.gov (United States)

    Li, Yuanyuan; Tolley, H Dennis; Lee, Milton L

    2010-07-23

    Rigid monoliths were synthesized solely from poly(ethylene glycol) diacrylates (PEGDA) or poly(ethylene glycol) dimethacrylates (PEGDMA) containing different ethylene glycol chain lengths by one-step UV-initiated polymerization. Methanol/ethyl ether and cyclohexanol/decanol were used as bi-porogen mixtures for the PEGDA and PEGDMA monoliths, respectively. Effects of PEG chain length, bi-porogen ratio and reaction temperature on monolith morphology and back pressure were investigated. For tri- and tetra-ethylene glycol diacrylates (i.e., PEGDA 258 and PEGDA 302), most combinations of methanol and ethyl ether were effective in forming monoliths, while for diacrylates containing longer chain lengths (i.e., PEGDA 575 and PEGDA 700), polymerization became more sensitive to the bi-porogen ratio. A similar tendency was also observed for PEGDMA monomers. Polymerization of monoliths was conducted at approximately 0 degrees C and room temperature, which produced significant differences in monolith morphology and permeability. Monoliths prepared from PEGDA 258 were found to provide the best chromatographic performance with respect to peak capacity and resolution in hydrophobic interaction chromatography (HIC). Detailed study of these monoliths demonstrated that chromatographic performance was not affected by changing the ratios of the two porogens, but resulted in almost identical retention times and comparable peak capacities. An optimized PEGDA 258 monolithic column was able to separate proteins using a 20-min elution gradient with a peak capacity of 62. Mass recoveries for test proteins were found to be greater than 90, indicating its excellent biocompatibility. All monoliths demonstrated nearly no swelling or shrinking in different polarity solvents, and most of them could be stored dry, indicating excellent stability due to their highly crosslinked networks. The preparation of these in situ polymerized single-monomer monolithic columns was highly reproducible. The

  5. A monolithic silicon detector telescope

    International Nuclear Information System (INIS)

    Cardella, G.; Amorini, F.; Cabibbo, M.; Di Pietro, A.; Fallica, G.; Franzo, G.; Figuera, P.; Papa, M.; Pappalardo, G.; Percolla, G.; Priolo, F.; Privitera, V.; Rizzo, F.; Tudisco, S.

    1996-01-01

    An ultrathin silicon detector (1 μm) thick implanted on a standard 400 μm Si-detector has been built to realize a monolithic telescope detector for simultaneous charge and energy determination of charged particles. The performances of the telescope have been tested using standard alpha sources and fragments emitted in nuclear reactions with different projectile-target colliding systems. An excellent charge resolution has been obtained for low energy (less than 5 MeV) light nuclei. A multi-array lay-out of such detectors is under construction to charge identify the particles emitted in reactions induced by low energy radioactive beams. (orig.)

  6. Imaging monolithic silicon detector telescopes

    International Nuclear Information System (INIS)

    Amorini, F.; Sipala, V.; Cardella, G.; Boiano, C.; Carbone, B.; Cosentino, L.; Costa, E.; Di Pietro, A.; Emanuele, U.; Fallica, G.; Figuera, P.; Finocchiaro, P.; La Guidara, E.; Marchetta, C.; Pappalardo, A.; Piazza, A.; Randazzo, N.; Rizzo, F.; Russo, G.V.; Russotto, P.

    2008-01-01

    We show the results of some test beams performed on a new monolithic strip silicon detector telescope developed in collaboration with the INFN and ST-microelectronics. Using an appropriate design, the induction on the ΔE stages, generated by the charge released in the E stage, was used to obtain the position of the detected particle. The position measurement, together with the low threshold for particle charge identification, allows the new detector to be used for a large variety of applications due to its sensitivity of only a few microns measured in both directions

  7. Monolithic media for applications in affinity chromatography.

    Science.gov (United States)

    Sproß, Jens; Sinz, Andrea

    2011-08-01

    Affinity chromatography presents a highly versatile analytical tool, which relies on exploiting highly specific interactions between molecules and their ligands. This review covers the most recent literature on the application of monoliths as stationary phases for various affinity-based chromatographic applications. Different affinity approaches as well as separations using molecularly imprinted monoliths are discussed. Hybrid stationary phases created by embedding of particles or nanoparticles into a monolithic stationary phase are also considered in this review article. The ease of preparation of monoliths and the multitude of functionalization techniques, which have matured during the past years, make monoliths interesting for an increasing number of biochemical and medical applications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Applications of monolithic materials for sample preparation.

    Science.gov (United States)

    Nema, Tarang; Chan, Eric C Y; Ho, Paul C

    2014-01-01

    Recent advances in monolithic columns have made them an alternative to traditional packed columns used in liquid chromatography as well as capillary electrochromatography (CEC). The monolithic columns have been extensively studied and shown to possess several advantages that make them a promising and potential substitute for the particle packed columns. A large number of papers relating to monolithic columns have been published every year, focusing on different preparation techniques, characteristic evaluations as well as applications. This review highlighted the latest development of monoliths for other modes of analytical chemistry. In particular, this review will highlight the application of monoliths for sample preparation which is an important step of the entire analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Physico-chemical control on the REE minerals in chloritoid-grade metasediments from a single outcrop (Central Alps, Switzerland)

    DEFF Research Database (Denmark)

    Janots, Emilie; Berger, Alfons; Engi, Martin

    2011-01-01

    This study assesses the effects of fluid, whole-rock composition and oxygen fugacity, on the texture and composition of monazite, allanite, and xenotime. For this purpose, these were investigated in 13 monometamorphic metasediments from a single locality of the Central Alps (Switzerland), which...

  10. Low cost and highly integrated cop monolithic liquid flow controlling system

    NARCIS (Netherlands)

    Etxebarria, J.; Berganzo, J.; Anduaga, J.; Besteiro, J.; Brivio, M.; Gardeniers, H.; Ezkerra, A.

    2015-01-01

    In this work a polymer monolithic liquid flow controlling system (LFCS) at micro-scale is presented, which enables regulation between 30-230 μl/min with excellent reproducibility and accuracy. The device is made in a single piece by Hot Embossing in Cyclic Olefin Polymer, sealed with a single

  11. Monolithic pixels on moderate resistivity substrate and sparsifying readout architecture

    International Nuclear Information System (INIS)

    Giubilato, P.; Battaglia, M.; Bisello, D.; Caselle, M.; Chalmet, P.; Demaria, L.; Ikemoto, Y.; Kloukinas, K.; Mansuy, S.C.; Mattiazzo, S.; Marchioro, A.; Mugnier, H.; Pantano, D.; Potenza, A.; Rivetti, A.; Rousset, J.; Silvestrin, L.; Snoeys, W.

    2013-01-01

    The LePix projects aim realizing a new generation monolithic pixel detectors with improved performances at lesser cost with respect to both current state of the art monolithic and hybrid pixel sensors. The detector is built in a 90 nm CMOS process on a substrate of moderate resistivity. This allows charge collection by drift while maintaining the other advantages usually offered by MAPS, like having a single piece detector and using a standard CMOS production line. The collection by drift mechanism, coupled to the low capacitance design of the collecting node made possible by the monolithic approach, provides an excellent signal to noise ratio straight at the pixel cell together with a radiation tolerance far superior to conventional un-depleted MAPS. The excellent signal-to-noise performance is demonstrated by the device ability to separate the 6 keV 55 Fe double peak at room temperature. To achieve high granularity (10–20 µm pitch pixels) over large detector areas maintaining high readout speed, a completely new compressing architecture has been devised. This architecture departs from the mainstream hybrid pixel sparsification approach, which uses in-pixel logic to reduce data, by using topological compression to minimize pixel area and power consumption

  12. Monolithic pixels on moderate resistivity substrate and sparsifying readout architecture

    CERN Document Server

    Giubilato, P; Snoeys, W; Bisello, D; Marchioro, A; Battaglia, M; Demaria, L; Mansuy, S C; Pantano, D; Rousset, J; Mattiazzo, S; Kloukinas, K; Potenza, A; Ikemoto, Y; Rivetti, A; Chalmet, P; Mugnier, H; Silvestrin, L

    2013-01-01

    The LePix projects aim realizing a new generation monolithic pixel detectors with improved performances at lesser cost with respect to both current state of the art monolithic and hybrid pixel sensors. The detector is built in a 90 nm CMOS process on a substrate of moderate resistivity. This allows charge collection by drift while maintaining the other advantages usually offered by MAPS, like having a single piece detector and using a standard CMOS production line. The collection by drift mechanism, coupled to the low capacitance design of the collecting node made possible by the monolithic approach, provides an excellent signal to noise ratio straight at the pixel cell together with a radiation tolerance far superior to conventional un-depleted MAPS. The excellent signal-to-noise performance is demonstrated by the device ability to separate the 6 keV Fe-55 double peak at room temperature. To achieve high granularity (10-20 mu m pitch pixels) over large detector areas maintaining high readout speed, a complet...

  13. Rapid and simple preparation of thiol-ene emulsion-templated monoliths and their application as enzymatic microreactors

    DEFF Research Database (Denmark)

    Lafleur, Josiane P; Senkbeil, Silja; Novotny, Jakub

    2015-01-01

    A novel, rapid and simple method for the preparation of emulsion-templated monoliths in microfluidic channels based on thiol-ene chemistry is presented. The method allows monolith synthesis and anchoring inside thiol-ene microchannels in a single photoinitiated step. Characterization by scanning...... electron microscopy showed that the methanol-based emulsion templating process resulted in a network of highly interconnected and regular thiol-ene beads anchored solidly inside thiol-ene microchannels. Surface area measurements indicate that the monoliths are macroporous, with no or little micro...

  14. A single cause for uplift of the Central and Eastern Anatolian plateau?

    NARCIS (Netherlands)

    Bartol, Jeroen; Govers, Rob

    2014-01-01

    Regional observations suggest that the Central Anatolian plateau (central Turkey) has risen by > 1 km since the Tortonian (~ 8 Ma) while significant crustal shortening did not occur. This uplift was preceded by the onset of widespread volcanism (~ 14–9 Ma). The lithospheric context of these events

  15. Preparation and application of hydrophilic monolithic columns.

    Science.gov (United States)

    Jiang, Zhengjin; Smith, Norman William; Liu, Zhenghua

    2011-04-29

    Hydrophilic interaction chromatography (HILIC) has experienced increasing attention in recent years. Much research has been carried out in the area of HILIC separation mechanisms, column techniques and applications. Because of their good permeability, low resistance to mass transfer and easy preparation within capillaries, hydrophilic monolithic columns represent a trend among novel HILIC column techniques. This review attempts to present an overview of the preparation and applications of HILIC monolithic columns carried out in the past decade. The separation mechanism of various hydrophilic monolithic stationary phases is also reviewed. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Positional changes of maxillary central incisors following orthodontic treatment using single-crown implants as fixed reference markers

    DEFF Research Database (Denmark)

    Brahem Ben, Elissa; Holm, Bente; Sonnesen, L

    2017-01-01

    . MATERIALS AND METHODS: Fifty-seven patients - thirty-seven with (test group) and twenty without pre-implant orthodontic treatment (control group) - were rehabilitated with 89 single-crown implants in the upper maxilla. Clinical and radiographic data, clinical photographs, and dental casts were collected......OBJECTIVES: This follow-up study (1) compares tooth displacement of central incisors in patients with and without pre-implant orthodontic treatment and (2) investigates whether sex, age, or orthodontic retention have an effect on tooth displacement after the insertion of single-crown implants...... during baseline examinations after prosthetic rehabilitation and at the final follow-up examination at least 5 years later. A total of 114 dental casts were digitalized and aligned using a software program to measure changes in the positions of the central incisors. RESULTS: After a follow-up period...

  17. Optimization of monolithic columns for microfluidic devices

    Science.gov (United States)

    Pagaduan, Jayson V.; Yang, Weichun; Woolley, Adam T.

    2011-06-01

    Monolithic columns offer advantages as solid-phase extractors because they offer high surface area that can be tailored to a specific function, fast mass transport, and ease of fabrication. Porous glycidyl methacrylate-ethylene glycol dimethacrylate monoliths were polymerized in-situ in microfluidic devices, without pre-treatment of the poly(methyl methacrylate) channel surface. Cyclohexanol, 1-dodecanol and Tween 20 were used to control the pore size of the monoliths. The epoxy groups on the monolith surface can be utilized to immobilize target-specific probes such as antibodies, aptamers, or DNA for biomarker detection. Microfluidic devices integrated with solid-phase extractors should be useful for point-of-care diagnostics in detecting specific biomarkers from complex biological fluids.

  18. MONOLITHIC DISK FOR THE FAST CHROMATOGRAPHIC SEPARATION

    Directory of Open Access Journals (Sweden)

    Nurul Hidayat Aprilita

    2010-06-01

    Full Text Available Poly(styrene/divinylbenzene (PS/DVB monolithic disk was prepared by in situ free-radical copolymerization of styrene and divinylbenzene in the presence of decanol and tetrahydrofuran as porogens. PS/DVB monolithic disks were produced in two different lengths 1.5 mm and 3 mm. The disks were used in reversed phase chromatography of proteins with 0.2 % trifuoroacetic acid (TFA and 0.2 % TFA in acetonitrile as mobile phase A and B, respectively. The effect of gradient rate, flow rate, temperature and disk length on the separation of proteins were also studied. PS/DVB monolithic disks allow the rapid separation of proteins in reversed phase chromatography. Keywords: monolithic disk, poly(styrene/divinylbenzene, proteins

  19. Monolithic Time Delay Integrated APD Arrays Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall goal of the proposed program by Epitaxial Technologies is to develop monolithic time delay integrated avalanche photodiode (APD) arrays with sensitivity...

  20. A Proposed Solution for Managing Doctor's Smart Cards in Hospitals Using a Single Sign-On Central Architecture

    OpenAIRE

    Mauro, Christian;Sunyaev, Ali;Leimeister, Jan Marco;Schweiger, Andreas;Krcmar, Helmut

    2014-01-01

    This paper describes a single sign-on solution for the central management of health care provider?s smart cards in hospitals. The proposed approach which is expected to be an improvement over current methods is made possible through the introduction of a national healthcare telematics infrastructure in Germany where every physician and every patient will automatically be given an electronic health smart card (for patients) and a corresponding health professional card (for health care provider...

  1. Single-nucleotide polymorphisms and DNA methylation markers associated with central obesity and regulation of body weight.

    Science.gov (United States)

    Goni, Leticia; Milagro, Fermín I; Cuervo, Marta; Martínez, J Alfredo

    2014-11-01

    Visceral fat is strongly associated with the development of specific obesity-related metabolic alterations. Genetic and epigenetic mechanisms seem to be involved in the development of obesity and visceral adiposity. The aims of this review are to identify the single-nucleotide polymorphisms related to central obesity and to summarize the main findings on DNA methylation and obesity. A search of the MEDLINE database was conducted to identify genome-wide association studies, meta-analyses of genome-wide association studies, and gene-diet interaction studies related to central obesity, and, in addition, studies that analyzed DNA methylation in relation to body weight regulation. A total of 8 genome-wide association studies and 9 meta-analyses of genome-wide association studies reported numerous single-nucleotide polymorphisms to be associated with central obesity. Ten studies analyzed gene-diet interactions and central obesity, while 2 epigenome-wide association studies analyzed DNA methylation patterns and obesity. Nine studies investigated the relationship between DNA methylation and weight loss, excess body weight, or adiposity outcomes. Given the development of new sequencing and omics technologies, significantly more knowledge on genomics and epigenomics of obesity and body fat distribution will emerge in the near future. © 2014 International Life Sciences Institute.

  2. Wideband Monolithic Tile for Reconfigurable Phased Arrays

    Science.gov (United States)

    2017-03-01

    Wideband Monolithic Tile for Reconfigurable Phased Arrays James J. Komiak1, Ryan S. Westafer2, Nancy V. Saldanha2, Randall Lapierre1, R. Todd...Lee2 BAE Systems Electronic Systems1, Georgia Tech Research Institute2 Abstract: A Wideband Monolithic 6 x 6 Tile of interconnected Quad Switches...circuits. The Tile incorporates 36 such Quad Switches, having 288 PHEMT devices controlled by 144 control lines and 300 bias resistors. To the

  3. Decomposition of monolithic web application to microservices

    OpenAIRE

    Zaymus, Mikulas

    2017-01-01

    Solteq Oyj has an internal Wellbeing project for massage reservations. The task of this thesis was to transform the monolithic architecture of this application to microservices. The thesis starts with a detailed comparison between microservices and monolithic application. It points out the benefits and disadvantages microservice architecture can bring to the project. Next, it describes the theory and possible strategies that can be used in the process of decomposition of an existing monoli...

  4. Monolithic ceramic capacitors for high reliability applications

    Science.gov (United States)

    Thornley, E. B.

    1981-01-01

    Monolithic multi-layer ceramic dielectric capacitors are widely used in high reliability applications in spacecraft, launch vehicles, and military equipment. Their relatively low cost, wide range of values, and package styles are attractive features that result in high usage in electronic circuitry in these applications. Design and construction of monolithic ceramic dielectric capacitors, defects that can lead to failure, and methods for defect detection that are being incorporated in military specifications are discussed.

  5. Monolithic multinozzle emitters for nanoelectrospray mass spectrometry

    Science.gov (United States)

    Wang, Daojing [Daly City, CA; Yang, Peidong [Kensington, CA; Kim, Woong [Seoul, KR; Fan, Rong [Pasadena, CA

    2011-09-20

    Novel and significantly simplified procedures for fabrication of fully integrated nanoelectrospray emitters have been described. For nanofabricated monolithic multinozzle emitters (NM.sup.2 emitters), a bottom up approach using silicon nanowires on a silicon sliver is used. For microfabricated monolithic multinozzle emitters (M.sup.3 emitters), a top down approach using MEMS techniques on silicon wafers is used. The emitters have performance comparable to that of commercially-available silica capillary emitters for nanoelectrospray mass spectrometry.

  6. A monolithically integrated magneto-optoelectronic circuit

    Science.gov (United States)

    Saha, D.; Basu, D.; Bhattacharya, P.

    2008-11-01

    The monolithic integration of a spin valve, an amplifier, and a light emitting diode to form a magneto-optoelectronic integrated circuit on GaAs is demonstrated. The circuit converts the spin polarization information in the channel of the spin valve to an amplified change in light intensity with a gain of 20. The monolithic circuit therefore operates as a magnetoelectronic switch which modulates the light intensity of the light emitting diode.

  7. Methacrylate Polymer Monoliths for Separation Applications

    Directory of Open Access Journals (Sweden)

    Robert J. Groarke

    2016-06-01

    Full Text Available This review summarizes the development of methacrylate-based polymer monoliths for separation science applications. An introduction to monoliths is presented, followed by the preparation methods and characteristics specific to methacrylate monoliths. Both traditional chemical based syntheses and emerging additive manufacturing methods are presented along with an analysis of the different types of functional groups, which have been utilized with methacrylate monoliths. The role of methacrylate based porous materials in separation science in industrially important chemical and biological separations are discussed, with particular attention given to the most recent developments and challenges associated with these materials. While these monoliths have been shown to be useful for a wide variety of applications, there is still scope for exerting better control over the porous architectures and chemistries obtained from the different fabrication routes. Conclusions regarding this previous work are drawn and an outlook towards future challenges and potential developments in this vibrant research area are presented. Discussed in particular are the potential of additive manufacturing for the preparation of monolithic structures with pre-defined multi-scale porous morphologies and for the optimization of surface reactive chemistries.

  8. Methacrylate Polymer Monoliths for Separation Applications

    Science.gov (United States)

    Groarke, Robert J.; Brabazon, Dermot

    2016-01-01

    This review summarizes the development of methacrylate-based polymer monoliths for separation science applications. An introduction to monoliths is presented, followed by the preparation methods and characteristics specific to methacrylate monoliths. Both traditional chemical based syntheses and emerging additive manufacturing methods are presented along with an analysis of the different types of functional groups, which have been utilized with methacrylate monoliths. The role of methacrylate based porous materials in separation science in industrially important chemical and biological separations are discussed, with particular attention given to the most recent developments and challenges associated with these materials. While these monoliths have been shown to be useful for a wide variety of applications, there is still scope for exerting better control over the porous architectures and chemistries obtained from the different fabrication routes. Conclusions regarding this previous work are drawn and an outlook towards future challenges and potential developments in this vibrant research area are presented. Discussed in particular are the potential of additive manufacturing for the preparation of monolithic structures with pre-defined multi-scale porous morphologies and for the optimization of surface reactive chemistries. PMID:28773570

  9. A single cause for uplift of the Central and Eastern Anatolian plateau?

    Science.gov (United States)

    Govers, Rob; Bartol, Jeroen

    2015-04-01

    Regional observations suggest that the Central Anatolian platearal (central Turkey) has risen by more than since the Tortonian (~8 Ma) while significant crustal shortening did not occur. This uplift was preceded by the onset of widespread volcanism (~14-9Ma). The lithospheric context of these events is however unknown. For the Eastern Anatolian plateau, similar events have been attributed to the late-stage evolution of the northern Neotethys slab, resulting in delamination and slab break-off. Recent tomographic results indicate that this slab extended beneath both below the Eastern and Central Anatolian plateau just prior to delamination. We propose a new lithospheric scenario for the regional evolution in the Aegean-Anatolia-Near East region that combines a recent compilation of surface geology data with the structure of the upper mantle. Following Cretaceous-Eocene closure of the northern Neotethys, Africa-Eurasia convergence was accommodated by horizontal subduction at a trench that was located south of Anatolia. Like before the closure, the northern Neotethys slab continued to sink into the deeper mantle beneath the Izmir-Ankara-Erzincan suture. In the early Miocene (~20-15Ma), the northern Neotethys slab started to retreat southward to the trench, resulting in delamination of the lithospheric mantle. The last part of this scenario is testable, whether delamination can explain the uplift of both the Central and Eastern Anatolian plateau. In the east, uplift due to collision of Arabia is included. We use a coupled thermal-flexural model of the lithosphere. Delamination can explain the average present-day long-wavelength topography of the Central Anatolian plateau. For the Eastern Anatolian plateau, delamination explains half the present-day elevation: the other half resulted from crustal thickening. We therefore propose to refer to central and east Anatolia since the middle Miocene as "the Anatolian plateau".

  10. Polymer monolith microextraction using poly(butyl methacrylate-co-1,6-hexanediol ethoxylate diacrylate) monolithic sorbent for determination of phenylurea herbicides in water samples.

    Science.gov (United States)

    Lin, Shu-Ling; Wu, Yu-Ru; Fuh, Ming-Ren

    2016-01-15

    In this study, recently developed 1,6-hexanediol ethoxylate diacrylate (HEDA)-based polymeric monoliths were utilized as sorbents for efficient extraction of phenylurea herbicides (PUHs) from water samples. The HEDA-based monolithic sorbents were prepared in a fused silica capillary (0.7mm i.d., 4.5-cm long) for polymer monolith microextraction (PMME). The experimental parameters of PMME microextraction including sample loading speed, pH of sample solution, composition of elution solvent, and addition of salt were optimized to efficiently extract PUHs from environmental water samples. The extracted PUHs were determined using ultra-high performance liquid chromatography (UHPLC) with UV-photodiode array detection. The extraction recoveries for PUHs-spiked water samples were 91.1-108.1% with relative standard deviations lower than 5%. The linearity range was 0.025-25ngmL(-1) for each PUH and the detection limits of PUHs were estimated at 0.006-0.019ng mL(-1). In addition, good intra-day/inter-day precision (0.1-8.7%/0.2-8.9%) and accuracy (92.0-108.0%/96.5-105.2%) of the proposed method were obtained. The extraction capacity of the monolith-filled capillary was also determined to be approximately 1μg. Moreover, each monolith-filled capillary could be reused up to 8 times without carry-over. According to the European Union regulations, the allowed permissible limit of any single herbicide in drinking water is 0.1ng mL(-1). This permissible level fell in the linear range examined in this study. In addition, the proposed method provided detection limits lower than the allowed permissible level, which demonstrated the feasibility of utilizing the HEDA-based monolithic sorbent to perform PMME for determining contaminants, such as PUHs, in environmental application. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Monolithic fiber-top sensor for critical environments and standard applications

    NARCIS (Netherlands)

    Iannuzzi, D.; Deladi, S.; Gadgil, V. J.; Sanders, R.W.; Schreuders, H.; Elwenspoek, M. C.

    2006-01-01

    We present a monolithic device obtained by carving a cantilever on the top of a single-mode optical fiber. We show that the vertical position of the cantilever can be determined with accuracy comparable to atomic force microscopes and other commonly used scientific instruments. The device does not

  12. Continuous-Flow Monolithic Silica Microreactors with Arenesulphonic Acid Groups: Structure–Catalytic Activity Relationships

    Directory of Open Access Journals (Sweden)

    Agnieszka Ciemięga

    2017-08-01

    Full Text Available The performance of monolithic silica microreactors activated with sulphonic acid groups and a packed bed reactor with Amberlyst 15 resin were compared in the esterification of acetic acid with n-butanol. The monolithic microreactors were made of single silica rods with complex pore architecture, differing in the size of mesopores, and in particular, flow-through macropores which significantly affected the flow characteristic of the continuous system. The highest ester productivity of 105.2 mol·molH+−1·h−1 was achieved in microreactor M1 with the largest porosity, characterized by a total pore volume of 4 cm3·g−1, mesopores with 20 nm diameter, and large flow-through macropores 30–50 μm in size. The strong impact of the permeability of the monoliths on a reaction kinetics was shown.

  13. A neutron polarisation analysis study of the 'central' peak in single-crystal praseodymium

    International Nuclear Information System (INIS)

    Burke, S.K.; Stirling, W.G.; McEwen, K.A.; Salford Univ.

    1981-01-01

    The technique of neutron polarisation analysis has been used to examine the broad 'central' peak in paramagnetic praseodymium. Measurements over the temperature range 1.2-25 K show that these peaks, observed at reciprocal space positions (Q 1 , 0, 2m + 1) with Q 1 = 0.11 tau 100 , are entirely magnetic in character. The relationship between these short-range magnetic correlations and the long-range antiferromagnetic ordering process is discussed. (author)

  14. Sharp Central Venous Recanalization in Hemodialysis Patients: A Single-Institution Experience

    Energy Technology Data Exchange (ETDEWEB)

    Arabi, Mohammad, E-mail: marabi2004@hotmail.com; Ahmed, Ishtiaq; Mat’hami, Abdulaziz [Prince Sultan Military Medical City (PSMMC), Division of Endovascular Interventional Radiology, Department of Medical Imaging (Saudi Arabia); Ahmed, Dildar; Aslam, Naveed [Prince Sultan Military Medical City (PSMMC), Department of Nephrology (Saudi Arabia)

    2016-06-15

    PurposeWe report our institutional experience with sharp central venous recanalization in chronic hemodialysis patients who failed standard techniques.Materials and MethodsSince January 2014, a series of seven consecutive patients (four males and three females), mean age 35 years (18–65 years), underwent sharp central venous recanalization. Indications included obtaining hemodialysis access (n = 6) and restoration of superior vena cava (SVC) patency to alleviate occlusion symptoms and restore fistula function (n = 1). The transseptal needle was used for sharp recanalization in six patients, while it could not be introduced in one patient due to total occlusion of the inferior vena cava. Instead, transmediastinal SVC access using Chiba needle was obtained.ResultsTechnical success was achieved in all cases. SVC recanalization achieved symptoms’ relief and restored fistula function in the symptomatic patient. One patient underwent arteriovenous fistula creation on the recanalized side 3 months after the procedure. The remaining catheters were functional at median follow-up time of 9 months (1–14 months). Two major complications occurred including a right hemothorax and a small hemopericardium, which were managed by covered stent placement across the perforated SVC.ConclusionSharp central venous recanalization using the transseptal needle is feasible technique in patients who failed standard recanalization procedures. The potential high risk of complications necessitates thorough awareness of anatomy and proper technical preparedness.

  15. 10Gbps monolithic silicon FTTH transceiver for PON

    Science.gov (United States)

    Zhang, J.; Liow, T. Y.; Lo, G. Q.; Kwong, D. L.

    2010-05-01

    We propose a new passive optical network (PON) configuration and a novel silicon photonic transceiver architecture for optical network unit (ONU), eliminating the need for an internal laser source in ONU. We adopt dual fiber network configuration. The internal light source in each of the ONUs is eliminated. Instead, an extra seed laser source in the optical line termination (OLT) operates in continuous wave mode to serve the ONUs in the PON as a shared and centralized laser source. λ1 from OLT Tx and λ2 from the seed laser are combined by using a WDM combiner and connected to serve the multiple ONUs through the downstream fibers. The ONUs receive the data in λ1. Meanwhile, the ONUs encode and transmit data in λ2, which are sent back to OLT. The monolithic ONU transceiver contains a wavelength-division-multiplexing (WDM) filter component, a silicon modulator and a Ge photo-detector. The WDM in ONU selectively guides λ1 to the Ge-PD where the data in λ1 are detected and converted to electrical signals, and λ2 to the transmitter where the light is modulated by upstream data. The modulated optical signals in λ2 from ONUs are connected back to OLT through upstream fibers. The monolithic ONU transceiver chip size is only 2mm by 4mm. The crosstalk between the Tx and Rx is measured to be less than -20dB. The transceiver chip is integrated on a SFP+ transceiver board. Both Tx and Rx demonstrated data rate capabilities of up to 10Gbps. By implementing this scheme, the ONU transceiver size can be significantly reduced and the assembly processes will be greatly simplified. The results demonstrate the feasibility of mass manufacturing monolithic silicon ONU transceivers via low cost

  16. Positional changes of maxillary central incisors following orthodontic treatment using single-crown implants as fixed reference markers.

    Science.gov (United States)

    Brahem, E B; Holm, B; Sonnesen, L; Worsaae, N; Gotfredsen, K

    2017-12-01

    This follow-up study (1) compares tooth displacement of central incisors in patients with and without pre-implant orthodontic treatment and (2) investigates whether sex, age, or orthodontic retention have an effect on tooth displacement after the insertion of single-crown implants. Fifty-seven patients - thirty-seven with (test group) and twenty without pre-implant orthodontic treatment (control group) - were rehabilitated with 89 single-crown implants in the upper maxilla. Clinical and radiographic data, clinical photographs, and dental casts were collected during baseline examinations after prosthetic rehabilitation and at the final follow-up examination at least 5 years later. A total of 114 dental casts were digitalized and aligned using a software program to measure changes in the positions of the central incisors. After a follow-up period of at least five years, 87% of the central incisors measured in the test group were displaced >0.25 mm vertically compared with 70% in the control group. Seventy-eight percent of the test group teeth had moved >0.25 mm horizontally compared with 55% in the control group. These differences were not significant, and there were no significant correlations with patient age or sex. The majority of patients had minor vertical (60%) or horizontal (67%) tooth displacement of the central incisors (0.25-0.75 mm) after a minimum follow-up period of 5 years. This study found no significant differences in tooth displacement comparing patients with and without pre-implant orthodontic treatment. No significant effect of sex, age, orthodontic retention, or implant location was observed on tooth displacement. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Surfactant-bound monolithic columns for CEC.

    Science.gov (United States)

    Gu, Congying; He, Jun; Jia, Jinping; Fang, Nenghu; Shamsi, Shahab A

    2009-11-01

    A novel anionic surfactant bound monolithic stationary phase based on 11-acrylaminoundecanoic acid is designed for CEC. The monolith possessing bonded undecanoyl groups (hydrophobic sites) and carboxyl groups (weak cationic ion-exchange sites) were evaluated as a mixed-mode stationary phase in CEC for the separation of neutral and polar solutes. Using a multivariate D-optimal design the composition of the polymerization mixture was modeled and optimized with five alkylbenzenes and seven alkyl phenyl ketones as test solutes. The D-optimal design indicates a strong dependence of electrochromatographic parameters on the concentration of 11-acrylaminoundecanoic acid monomer and porogen (water) in the polymerization mixture. A difference of 6, 8 and 13% RSD between the predicted and the experimental values in terms of efficiency, resolution and retention time, respectively, indeed confirmed that the proposed approach is practical. The physical (i.e. morphology, porosity and permeability) and chromatographic properties of the monolithic columns were thoroughly investigated. With the optimized monolithic column, high efficiency separation of N-methylcarbamates pesticides and positional isomers was successfully achieved. It appears that this type of mixed-mode monolith (containing both chargeable and hydrophobic sites) may have a great potential as a new generation of CEC stationary phase.

  18. Taking a Large Monolith to Use for Teaching Soil Morphology.

    Science.gov (United States)

    Smith, B. R.; And Others

    1989-01-01

    Described is a technique for taking a large monolith for the purpose of teaching soil structure. Materials and procedures are detailed. A survey of 93 students indicated that the larger monolith was preferred over the commonly used narrow ones. (CW)

  19. Fracture resistance of monolithic zirconia molar crowns with reduced thickness

    OpenAIRE

    Nakamura, Keisuke; Harada, A.; Inagaki, R.; Kanno, Taro; Niwano, Y.; Milleding, Percy; Ørtengren, Ulf Thore

    2015-01-01

    This is the accepted manuscript version. Published version is available at Acta Odontologica Scandinavica Objectives. The purpose of the present study was to analyze the relationship between fracture load of monolithic zirconia crowns and axial/occlusal thickness, and to evaluate the fracture resistance of monolithic zirconia crowns with reduced thickness in comparison with that of monolithic lithium disilicate crowns with regular thickness. Materials and methods. Monolithic zi...

  20. Eigenpolarization theory of monolithic nonplanar ring oscillators

    Science.gov (United States)

    Nilsson, Alan C.; Gustafson, Eric K.; Byer, Robert L.

    1989-01-01

    Diode-laser-pumped monolithic nonplanar ring oscillators (NPROs) in an applied magnetic field can operate as unidirectional traveling-wave lasers. The diode laser pumping, monolithic construction, and unidirectional oscillation lead to narrow linewidth radiation. Here, a comprehensive theory of the eigenpolarizations of a monolithic NPRO is presented. It is shown how the properties of the integral optical diode that forces unidirectional operation depend on the choice of the gain medium, the applied magnetic field, the output coupler, and the geometry of the nonplanar ring light path. Using optical equivalence theorems to gain insight into the polarization characteristics of the NPRO, a strategy for designing NPROs with low thresholds and large loss nonreciprocities is given. An analysis of the eigenpolarizations for one such NPRO is presented, alternative optimization approaches are considered, and the prospects for further reducing the linewidths of these lasers are briefly discussed.

  1. Mass transfer kinetic mechanism in monolithic columns and application to the characterization of new research monolithic samples with different average pore sizes.

    Science.gov (United States)

    Gritti, Fabrice; Guiochon, Georges

    2009-06-05

    A general reduced HETP (height equivalent to a theoretical plate) equation is proposed that accounts for the mass transfer of a wide range of molecular weight compounds in monolithic columns. The detailed derivatization of each one of the individual and independent mass transfer contributions (longitudinal diffusion, eddy dispersion, film mass transfer resistance, and trans-skeleton mass transfer resistance) is discussed. The reduced HETPs of a series of small molecules (phenol, toluene, acenaphthene, and amylbenzene) and of a larger molecule, insulin, were measured on three research grade monolithic columns (M150, M225, M350) having different average pore size (approximately 150, 225, and 350 A, respectively) but the same dimension (100 mm x 4.6 mm). The first and second central moments of 2 muL samples were measured and corrected for the extra-column contributions. The h data were fitted to the new HETP equation in order to identify which contribution controls the band broadening in monolithic columns. The contribution of the B-term was found to be negligible compared to that of the A-term, even at very low reduced velocities (nu5), the C-term of the monolithic columns is controlled by film mass transfer resistance between the eluent circulating in the large throughpores and the eluent stagnant inside the thin porous skeleton. The experimental Sherwood number measured on the monolith columns increases from 0.05 to 0.22 while the adsorption energy increases by nearly 6 kJ/mol. Stronger adsorption leads to an increase in the value of the estimated film mass transfer coefficient when a first order film mass transfer rate is assumed (j proportional, variantk(f)DeltaC). The average pore size and the trans-skeleton mass transfer have no (<0.5%, small molecules) or little (<10%, insulin) effect on the overall C-term.

  2. UPDATE ON MONOLITHIC FUEL FABRICATION METHODS

    Energy Technology Data Exchange (ETDEWEB)

    C. R. Clark; J. F. Jue; G. A. Moore; N. P. Hallinan; B. H. Park; D. E. Burkes

    2006-10-01

    Efforts to develop a viable monolithic research reactor fuel plate have continued at Idaho National Laboratory. These efforts have concentrated on both fabrication process refinement and scale-up to produce full sized fuel plates. Progress at INL has led to fabrication of hot isostatic pressed uranium-molybdenum bearing monolithic fuel plates. These miniplates are part of the RERTR-8 miniplate irradiation test. Further progress has also been made on friction stir weld processing which has been used to fabricate full size fuel plates which will be irradiated in the ATR and OSIRIS reactors.

  3. Macroporous Monolithic Polymers: Preparation and Applications

    Science.gov (United States)

    Arrua, Ruben Dario; Strumia, Miriam Cristina; Alvarez Igarzabal, Cecilia Inés

    2009-01-01

    In the last years, macroporous monolithic materials have been introduced as a new and useful generation of polymers used in different fields. These polymers may be prepared in a simple way from a homogenous mixture into a mold and contain large interconnected pores or channels allowing for high flow rates at moderate pressures. Due to their porous characteristics, they could be used in different processes, such as stationary phases for different types of chromatography, high-throughput bioreactors and in microfluidic chip applications. This review reports the contributions of several groups working in the preparation of different macroporous monoliths and their modification by immobilization of specific ligands on the products for specific purposes.

  4. Technology development for SOI monolithic pixel detectors

    International Nuclear Information System (INIS)

    Marczewski, J.; Domanski, K.; Grabiec, P.; Grodner, M.; Jaroszewicz, B.; Kociubinski, A.; Kucharski, K.; Tomaszewski, D.; Caccia, M.; Kucewicz, W.; Niemiec, H.

    2006-01-01

    A monolithic detector of ionizing radiation has been manufactured using silicon on insulator (SOI) wafers with a high-resistivity substrate. In our paper the integration of a standard 3 μm CMOS technology, originally designed for bulk devices, with fabrication of pixels in the bottom wafer of a SOI substrate is described. Both technological sequences have been merged minimizing thermal budget and providing suitable properties of all the technological layers. The achieved performance proves that fully depleted monolithic active pixel matrix might be a viable option for a wide spectrum of future applications

  5. Increased thermal conductivity monolithic zeolite structures

    Science.gov (United States)

    Klett, James; Klett, Lynn; Kaufman, Jonathan

    2008-11-25

    A monolith comprises a zeolite, a thermally conductive carbon, and a binder. The zeolite is included in the form of beads, pellets, powders and mixtures thereof. The thermally conductive carbon can be carbon nano-fibers, diamond or graphite which provide thermal conductivities in excess of about 100 W/mK to more than 1,000 W/mK. A method of preparing a zeolite monolith includes the steps of mixing a zeolite dispersion in an aqueous colloidal silica binder with a dispersion of carbon nano-fibers in water followed by dehydration and curing of the binder is given.

  6. Monolithic JFET preamplifier for ionization chamber calorimeter

    International Nuclear Information System (INIS)

    Radeka, V.; Rescia, S.; Manfredi, P.F.; Speziali, V.

    1990-10-01

    A monolithic charge sensitive preamplifier using exclusively n-channel diffused JFETs has been designed and is now being fabricated by INTERFET Corp. by means of a dielectrically isolated process which allows preserving as much as possible the technology upon which discrete JFETs are based. A first prototype built by means of junction isolated process has been delivered. The characteristics of monolithically integrated JFETs compare favorably with discrete devices. First results of tests of a preamplifier which uses these devices are reported. 4 refs

  7. Optical displacement measurement with GaAs/AlGaAs-based monolithically integrated Michelson interferometers

    OpenAIRE

    Hofstetter, Daniel; Zappe, H. P.; Dändliker, René

    2008-01-01

    Two monolithically integrated optical displacement sensors fabricated in the GaAs/AlGaAs material system are reported. These single-chip microsystems are configured as Michelson interferometers and comprise a distributed Bragg reflector (DBR) laser, photodetectors, phase shifters, and waveguide couplers. While the use of a single Michelson interferometer allows measurement of displacement magnitude only, a double Michelson interferometer with two interferometer signals in phase quadrature als...

  8. Preparation of polymer monolithic column functionalized by arsonic acid groups for mixed-mode capillary liquid chromatography.

    Science.gov (United States)

    Qin, Zhang-Na; Yu, Qiong-Wei; Wang, Ren-Qi; Feng, Yu-Qi

    2018-04-27

    A mixed-mode polymer monolithic column functionalized by arsonic acid groups was prepared by single-step in situ copolymerization of monomers p-methacryloylaminophenylarsonic acid (p-MAPHA) and pentaerythritol triacrylate (PETA). The prepared poly(p-MAPHA-co-PETA) monolithic column has a homogeneous monolithic structure with good permeability and mechanical stability. Zeta potential measurements reveal that the monolithic stationary phase holds a negative surface charge when the mobile phase resides in the pH range of 3.0-8.0. The retention mechanisms of prepared monolithic column are explored by the separation of selected polycyclic aromatic hydrocarbons (PAHs), nucleosides, and three basic compounds. The results indicate that the column functions in three different separation modes associated with reversed-phase chromatography based on hydrophobic interaction, hydrophilic interaction chromatography, and cation-exchange chromatography. The column efficiency of prepared monolithic column is estimated to be 70,000 and 76,000 theoretical plates/m for thiourea and naphthalene, respectively, at a linear flow velocity of 0.85 mm/s using acetonitrile/H 2 O (85/15, v/v) as the mobile phase. Furthermore, an analysis of the retention factors obtained for the PAHs indicates that the prepared monolithic column exhibits good reproducibility with relative standard deviations of 2.9%, 4.0%, and 4.7% based on run-to-run injections, column-to-column preparation, and batch-to-batch preparation, respectively. Finally, we investigate the separation performance of the proposed monolithic column for select phenols, sulfonamides, nucleobases and nucleosides. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Monolithic View of Galaxy Formation and Evolution

    Directory of Open Access Journals (Sweden)

    Cesare Chiosi

    2014-07-01

    Full Text Available We review and critically discuss the current understanding of galaxy formation and evolution limited to Early Type Galaxies (ETGs as inferred from the observational data and briefly contrast the hierarchical and quasi-monolithic paradigms of formation and evolution. Since in Cold Dark Matter (CDM cosmogony small scale structures typically collapse early and form low-mass haloes that subsequently can merge to assembly larger haloes, galaxies formed in the gravitational potential well of a halo are also expected to merge thus assembling their mass hierarchically. Mergers should occur all over the Hubble time and large mass galaxies should be in place only recently. However, recent observations of high redshift galaxies tell a different story: massive ETGs are already in place at high redshift. To this aim, we propose here a revision of the quasi-monolithic scenario as an alternative to the hierarchical one, in which mass assembling should occur in early stages of a galaxy lifetime and present recent models of ETGs made of Dark and Baryonic Matter in a Λ-CDM Universe that obey the latter scheme. The galaxies are followed from the detachment from the linear regime and Hubble flow at z ≥ 20 down to the stage of nearly complete assembly of the stellar content (z ∼ 2 − 1 and beyond.  It is found that the total mass (Mh = MDM + MBM and/or initial over-density of the proto-galaxy drive the subsequent star formation histories (SFH. Massive galaxies (Mh ~ _1012M⊙ experience a single, intense burst of star formation (with rates ≥ 103M⊙/yr at early epochs, consistently with observations, with a weak dependence on the initial over-density; intermediate mass haloes (Mh~_ 1010 − 1011M⊙ have star formation histories that strongly depend on their initial over-density; finally, low mass haloes (Mh ~_ 109M⊙ always have erratic, burst-like star forming histories. The present-day properties (morphology, structure, chemistry and photometry of the

  10. An analysis on single and central diffractive heavy flavour production at hadron colliders

    Energy Technology Data Exchange (ETDEWEB)

    Machado, M.V.T. [Universidade Federal do Pampa, Bage, RS (Brazil). Centro de Ciencias Exatas e Tecnologicas

    2008-09-15

    In this contribution results from a phenomenological analysis for the diffractive hadroproduction of heavy flavors at high energies are reported. Diffractive production of charm, bottom and top are calculated using the Regge factorization, taking into account recent experimental determination of the diffractive parton density functions in Pomeron by the H1 Collaboration at DESY-HERA. In addition, multiple-Pomeron corrections are considered through the rapidity gap survival probability factor. We give numerical predictions for single diffractive as well as double Pomeron exchange (DPE) cross sections, which agree with the available data for diffractive production of charm and beauty. We make estimates which could be compared to future measurements at the LHC. (author)

  11. [Preparation of monolithic materials and their applications in proteomic analysis].

    Science.gov (United States)

    Liang, Yu; Zhang, Lihua; Zhang, Yukui

    2011-09-01

    Proteomics is one of the core contents of life science in the post-genomic era, among which it is very important to develop the analytical techniques with high resolution, high sensitivity, high accuracy and high throughput. With the advantages of facile preparation, fast mass transfer, low backpressure and easy modification, monolithic materials have been widely used in proteomic analysis. This review summarizes the preparation methods of different kinds of monolithic materials (including organic polymer monoliths, silica-based monoliths, organic-inorganic hybrid silica monoliths) and their applications in proteomic study such as the digestion of proteins, the separation of proteins or peptides, high throughput analysis integrating online digestion, separation and identification.

  12. Seismic waves and earthquakes in a global monolithic model

    Science.gov (United States)

    Roubíček, Tomáš

    2018-03-01

    The philosophy that a single "monolithic" model can "asymptotically" replace and couple in a simple elegant way several specialized models relevant on various Earth layers is presented and, in special situations, also rigorously justified. In particular, global seismicity and tectonics is coupled to capture, e.g., (here by a simplified model) ruptures of lithospheric faults generating seismic waves which then propagate through the solid-like mantle and inner core both as shear (S) or pressure (P) waves, while S-waves are suppressed in the fluidic outer core and also in the oceans. The "monolithic-type" models have the capacity to describe all the mentioned features globally in a unified way together with corresponding interfacial conditions implicitly involved, only when scaling its parameters appropriately in different Earth's layers. Coupling of seismic waves with seismic sources due to tectonic events is thus an automatic side effect. The global ansatz is here based, rather for an illustration, only on a relatively simple Jeffreys' viscoelastic damageable material at small strains whose various scaling (limits) can lead to Boger's viscoelastic fluid or even to purely elastic (inviscid) fluid. Self-induced gravity field, Coriolis, centrifugal, and tidal forces are counted in our global model, as well. The rigorous mathematical analysis as far as the existence of solutions, convergence of the mentioned scalings, and energy conservation is briefly presented.

  13. Transferrable monolithic III-nitride photonic circuit for multifunctional optoelectronics

    Science.gov (United States)

    Shi, Zheng; Gao, Xumin; Yuan, Jialei; Zhang, Shuai; Jiang, Yan; Zhang, Fenghua; Jiang, Yuan; Zhu, Hongbo; Wang, Yongjin

    2017-12-01

    A monolithic III-nitride photonic circuit with integrated functionalities was implemented by integrating multiple components with different functions into a single chip. In particular, the III-nitride-on-silicon platform is used as it integrates a transmitter, a waveguide, and a receiver into a suspended III-nitride membrane via a wafer-level procedure. Here, a 0.8-mm-diameter suspended device architecture is directly transferred from silicon to a foreign substrate by mechanically breaking the support beams. The transferred InGaN/GaN multiple-quantum-well diode (MQW-diode) exhibits a turn-on voltage of 2.8 V with a dominant electroluminescence peak at 453 nm. The transmitter and receiver share an identical InGaN/GaN MQW structure, and the integrated photonic circuit inherently works for on-chip power monitoring and in-plane visible light communication. The wire-bonded monolithic photonic circuit on glass experimentally demonstrates in-plane data transmission at 120 Mb/s, paving the way for diverse applications in intelligent displays, in-plane light communication, flexible optical sensors, and wearable III-nitride optoelectronics.

  14. Monolithically Integrated High-β Nanowire Lasers on Silicon.

    Science.gov (United States)

    Mayer, B; Janker, L; Loitsch, B; Treu, J; Kostenbader, T; Lichtmannecker, S; Reichert, T; Morkötter, S; Kaniber, M; Abstreiter, G; Gies, C; Koblmüller, G; Finley, J J

    2016-01-13

    Reliable technologies for the monolithic integration of lasers onto silicon represent the holy grail for chip-level optical interconnects. In this context, nanowires (NWs) fabricated using III-V semiconductors are of strong interest since they can be grown site-selectively on silicon using conventional epitaxial approaches. Their unique one-dimensional structure and high refractive index naturally facilitate low loss optical waveguiding and optical recirculation in the active NW-core region. However, lasing from NWs on silicon has not been achieved to date, due to the poor modal reflectivity at the NW-silicon interface. We demonstrate how, by inserting a tailored dielectric interlayer at the NW-Si interface, low-threshold single mode lasing can be achieved in vertical-cavity GaAs-AlGaAs core-shell NW lasers on silicon as measured at low temperature. By exploring the output characteristics along a detection direction parallel to the NW-axis, we measure very high spontaneous emission factors comparable to nanocavity lasers (β = 0.2) and achieve ultralow threshold pump energies ≤11 pJ/pulse. Analysis of the input-output characteristics of the NW lasers and the power dependence of the lasing emission line width demonstrate the potential for high pulsation rates ≥250 GHz. Such highly efficient nanolasers grown monolithically on silicon are highly promising for the realization of chip-level optical interconnects.

  15. Monolithically Integrated Flexible Black Phosphorus Complementary Inverter Circuits.

    Science.gov (United States)

    Liu, Yuanda; Ang, Kah-Wee

    2017-07-25

    Two-dimensional (2D) inverters are a fundamental building block for flexible logic circuits which have previously been realized by heterogeneously wiring transistors with two discrete channel materials. Here, we demonstrate a monolithically integrated complementary inverter made using a homogeneous black phosphorus (BP) nanosheet on flexible substrates. The digital logic inverter circuit is demonstrated via effective threshold voltage tuning within a single BP material, which offers both electron and hole dominated conducting channels with nearly symmetric pinch-off and current saturation. Controllable electron concentration is achieved by accurately modulating the aluminum (Al) donor doping, which realizes BP n-FET with a room-temperature on/off ratio >10 3 . Simultaneously, work function engineering is employed to obtain a low Schottky barrier contact electrode that facilities hole injection, thus enhancing the current density of the BP p-FET by 9.4 times. The flexible inverter circuit shows a clear digital logic voltage inversion operation along with a larger-than-unity direct current voltage gain, while exhibits alternating current dynamic signal switching at a record high frequency up to 100 kHz and remarkable electrical stability upon mechanical bending with a radii as small as 4 mm. Our study demonstrates a practical monolithic integration strategy for achieving functional logic circuits on one material platform, paving the way for future high-density flexible electronic applications.

  16. A single aerobic exercise session accelerates movement execution but not central processing.

    Science.gov (United States)

    Beyer, Kit B; Sage, Michael D; Staines, W Richard; Middleton, Laura E; McIlroy, William E

    2017-03-27

    Previous research has demonstrated that aerobic exercise has disparate effects on speed of processing and movement execution. In simple and choice reaction tasks, aerobic exercise appears to increase speed of movement execution while speed of processing is unaffected. In the flanker task, aerobic exercise has been shown to reduce response time on incongruent trials more than congruent trials, purportedly reflecting a selective influence on speed of processing related to cognitive control. However, it is unclear how changes in speed of processing and movement execution contribute to these exercise-induced changes in response time during the flanker task. This study examined how a single session of aerobic exercise influences speed of processing and movement execution during a flanker task using electromyography to partition response time into reaction time and movement time, respectively. Movement time decreased during aerobic exercise regardless of flanker congruence but returned to pre-exercise levels immediately after exercise. Reaction time during incongruent flanker trials decreased over time in both an aerobic exercise and non-exercise control condition indicating it was not specifically influenced by exercise. This disparate influence of aerobic exercise on movement time and reaction time indicates the importance of partitioning response time when examining the influence of aerobic exercise on speed of processing. The decrease in reaction time over time independent of aerobic exercise indicates that interpreting pre-to-post exercise changes in behavior requires caution. Copyright © 2017 IBRO. Published by Elsevier Ltd. All rights reserved.

  17. Monolithic graphene oxide sheets with controllable composition.

    Science.gov (United States)

    Chu, Jae Hwan; Kwak, Jinsung; Kim, Sung-Dae; Lee, Mi Jin; Kim, Jong Jin; Park, Soon-Dong; Choi, Jae-Kyung; Ryu, Gyeong Hee; Park, Kibog; Kim, Sung Youb; Kim, Ji Hyun; Lee, Zonghoon; Kim, Young-Woon; Kwon, Soon-Yong

    2014-02-28

    Graphene oxide potentially has multiple applications and is typically prepared by solution-based chemical means. To date, the synthesis of a monolithic form of graphene oxide that is crucial to the precision assembly of graphene-based devices has not been achieved. Here we report the physical approach to produce monolithic graphene oxide sheets on copper foil using solid carbon, with tunable oxygen-to-carbon composition. Experimental and theoretical studies show that the copper foil provides an effective pathway for carbon diffusion, trapping the oxygen species dissolved in copper and enabling the formation of monolithic graphene oxide sheets. Unlike chemically derived graphene oxide, the as-synthesized graphene oxide sheets are electrically active, and the oxygen-to-carbon composition can be tuned during the synthesis process. As a result, the resulting graphene oxide sheets exhibit tunable bandgap energy and electronic properties. Our solution-free, physical approach may provide a path to a new class of monolithic, two-dimensional chemically modified carbon sheets.

  18. Methacrylate monolithic columns functionalized with epinephrine for capillary electrochromatography applications.

    Science.gov (United States)

    Carrasco-Correa, Enrique Javier; Ramis-Ramos, Guillermo; Herrero-Martínez, José Manuel

    2013-07-12

    Epinephrine-bonded polymeric monoliths for capillary electrochromatography (CEC) were developed by nucleophilic substitution reaction of epoxide groups of poly(glycidyl-methacrylate-co-ethylenedimethacrylate) (poly(GMA-co-EDMA)) monoliths using epinephrine as nucleophilic reagent. The ring opening reaction under dynamic conditions was optimized. Successful chemical modification of the monolith surface was ascertained by in situ Raman spectroscopy characterization. In addition, the amount of epinephrine groups that was bound to the monolith surface was evaluated by oxidation of the catechol groups with Ce(IV), followed by spectrophotometric measurement of unreacted Ce(IV). About 9% of all theoretical epoxide groups of the parent monolith were bonded to epinephrine. The chromatographic behavior of the epinephrine-bonded monolith in CEC conditions was assessed with test mixtures of alkyl benzenes, aniline derivatives and substituted phenols. In comparison to the poly(GMA-co-EDMA) monoliths, the epinephrine-bonded monoliths exhibited a much higher retention and slight differences in selectivity. The epinephrine-bonded monolith was further modified by oxidation with a Ce(IV) solution and compared with the epinephrine-bonded monoliths. The resulting monolithic stationary phases were evaluated in terms of reproducibility, giving RSD values below 9% in the parameters investigated. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. Testing the accuracy of a Bayesian central-dose model for single-grain OSL, using known-age samples

    DEFF Research Database (Denmark)

    Guerin, Guillaume; Combès, Benoit; Lahaye, Christelle

    2015-01-01

    remains a difficult task, given the typically considerable dispersion in equivalent dose values measured by OSL - and the numerous sources of such dispersion in measurements. Here, we present the study of 19 samples for which independent age control is available, and whose ages range from 2 to 46ka. Based......-grain OSL and reference ages is about twice as large for the standard approach (12%) as with the Bayesian model (7%). Statistical tests show that, based on our (limited) dataset, the difference between the two models seems to be significant for samples in the age range 4-46ka. Finally, the influence...... on multi-grain OSL age estimates, these samples are presumed to have been both well-bleached at burial, and unaffected by mixing after deposition. Two ways of estimating single-grain ages are then compared: the standard approach on the one hand, consisting of applying the Central Age Model to De values...

  20. Arterial and venous revascularization with bifurcation of a single central artery: a reliable strategy for Tamai Zone I replantation.

    Science.gov (United States)

    Hsu, Chung-Chen; Lin, Yu-Te; Moran, Steven L; Lin, Cheng-Hung; Wei, Fu-Chan; Lin, Chih-Hung

    2010-12-01

    Replantation of the distal phalanx and pulp can be performed to improve finger function and finger aesthetics; however, establishing adequate venous drainage is a challenge. Slattery et al. reported microsurgical reattachment of a partial distal phalanx with the use of a bifurcated terminal digital artery. The bifurcation was divided into two pedicles, one of which was used for venous drainage. In this article, the authors report their experience with a similar technique and propose a new algorithm for distal finger replantation. From January of 2008 to February of 2009, five replantations were performed using a single central artery. The replanted levels were pulp, avulsed fingertip of the thumb, and distal phalanges. There was no volar vein, dorsal vein, or second artery available in the amputated part for standard venous drainage. Venous drainage in all cases was established by creating an anastomosis from a branch of the solitary terminal artery to a recipient vein. All digits were replanted successfully without evidence of arterial insufficiency or venous congestion. Partial necrosis was not identified postoperatively in any of the five fingers. There were no cases of wound infection. A branch of the central solitary artery may be used successfully to reestablish venous outflow in cases of distal finger tip replantation. This technique allowed for the salvage of all fingers in this study without the use of leeches or other techniques used in cases of venous insufficiency.

  1. Evaluation of natural gas supply options for south east and central Europe. Part 1: Indicator definitions and single indicator analysis

    International Nuclear Information System (INIS)

    Afgan, Naim H.; Carvalho, Maria G.; Pilavachi, Petros A.; Martins, Nelson

    2007-01-01

    The need for diversification of energy sources is an immanent goal in long term energy strategy. In particular, this is of great importance for the natural gas supply. In this respect, evaluation and assessment of potential natural gas resources and their relation to consumers is of great importance. The natural gas supply in Europe is one of the main issues of European energy strategy to be followed in the future. In particular, the natural gas supply in the southeast countries is important. This paper provides a framework for understanding how much natural gas is available for use in south east and central Europe as well as the links to the recent supply of natural gas and its transport. The analysis is focused on evaluation of the potential routes for natural gas supply to the south east and central European countries. The potential options included in this analysis are the Yamal Route; Nabucco Route; West Balkan Route; LNG NEUM Route and Gas by Wire Route. In this analysis, attention is focused on the following indicators for assessment of potential options: environmental indicator; NG cost indicator; NG transport and royalty indicator; investment indicator; and NG demand indicator. The first part of this paper is devoted to the definition of the indicators and to single indicator analysis. (author)

  2. Improved Optics in Monolithic Perovskite/Silicon Tandem Solar Cells with a Nanocrystalline Silicon Recombination Junction

    KAUST Repository

    Sahli, Florent

    2017-10-09

    Perovskite/silicon tandem solar cells are increasingly recognized as promi­sing candidates for next-generation photovoltaics with performance beyond the single-junction limit at potentially low production costs. Current designs for monolithic tandems rely on transparent conductive oxides as an intermediate recombination layer, which lead to optical losses and reduced shunt resistance. An improved recombination junction based on nanocrystalline silicon layers to mitigate these losses is demonstrated. When employed in monolithic perovskite/silicon heterojunction tandem cells with a planar front side, this junction is found to increase the bottom cell photocurrent by more than 1 mA cm−2. In combination with a cesium-based perovskite top cell, this leads to tandem cell power-conversion efficiencies of up to 22.7% obtained from J–V measurements and steady-state efficiencies of up to 22.0% during maximum power point tracking. Thanks to its low lateral conductivity, the nanocrystalline silicon recombination junction enables upscaling of monolithic perovskite/silicon heterojunction tandem cells, resulting in a 12.96 cm2 monolithic tandem cell with a steady-state efficiency of 18%.

  3. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns.

    Science.gov (United States)

    Esquivel-Upshaw, J F; Kim, M J; Hsu, S M; Abdulhameed, N; Jenkins, R; Neal, D; Ren, F; Clark, A E

    2018-01-01

    To test the hypothesis that there is no difference in the in vivo maximum wear of enamel opposing monolithic zirconia crowns, enamel opposing porcelain fused to metal crowns and enamel opposing enamel. Thirty patients needing single crowns were randomized to receive either a monolithic zirconia or metal-ceramic crown. Two non-restored opposing teeth in the same quadrants were identified to serve as enamel controls. After cementation, quadrants were scanned for baseline data. Polyvinylsiloxane impressions were obtained and poured in white stone. Patients were recalled at six-months and one-year for re-impression. Stone models were scanned using a tabletop laserscanner to determine maximum wear. Statistical analysis was performed using Mann-Whitney U to determine any significant differences between the wear of enamel against zirconia and metal-ceramic crowns. Sixteen zirconia and 14 metal-ceramic crowns were delivered. There were no statistical differences in mean wear of crown types (p=0.165); enamel antagonists (p=0.235) and enamel controls (p=0.843) after one year. Monolithic zirconia exhibited comparable wear of enamel compared with metal-ceramic crowns and control enamel after one year. This study is clinically significant because the use of polished monolithic zirconia demonstrated comparable wear of opposing enamel to metal-ceramic and enamel antagonists. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Monolithic and core-shell columns in comprehensive two-dimensional HPLC: a review.

    Science.gov (United States)

    Jandera, Pavel; Hájek, Tomáš; Staňková, Magda

    2015-01-01

    The crucial point affecting the separation time in comprehensive two-dimensional liquid chromatography is the performance of the column used in the second dimension, which should allow highly efficient fast chromatographic separations in the short time available for the analysis of fractions transferred from the first to the second dimension (often 1 min or less). This can be accomplished on short columns packed with sub-2-μm particles, at the cost of very high operation pressure. Core-shell or silica monolithic columns have better permeability, and their use in the second dimension of comprehensive two-dimensional liquid chromatography with conventional liquid chromatography instrumentation is continuously increasing. Monolithic columns based on organic polymer matrices offer a wide selection of stationary phase chemistries, including new hydrophilic interaction liquid chromatography materials, which can be used in the design of novel two-dimensional separations. Some organic polymer monolithic materials offer a dual retention mechanism (reversed-phase hydrophilic interaction liquid chromatography), so a single column can be used in alternating runs for highly orthogonal off-line two-dimensional and even three-dimensional separations. In the present work, the properties of core-shell and silica gel monolithic columns are briefly summarized and their applications in two-dimensional separations of peptides, proteins, oligomer surfactants, fats and oils, carotenoids, phenolic and flavone compounds in plant extracts, food, and beverages are reviewed.

  5. Analysis of Catalytic Material Effect on the Photovoltaic Properties of Monolithic Dye-sensitized Solar Cells

    Directory of Open Access Journals (Sweden)

    Natalita Maulani Nursam

    2017-12-01

    Full Text Available Dye-sensitized solar cells (DSSC are widely developed due to their attractive appearance and simple fabrication processes. One of the challenges that arise in the DSSC fabrication involves high material cost associated with the cost of conductive substrate. DSSC with monolithic configuration was then developed on the basis of this motivation. In this contribution, titanium dioxide-based monolithic type DSSCs were fabricated on a single fluorine-doped transparent oxide coated glass using porous ZrO2 as spacer. Herein, the catalytic material for the counter-electrode was varied using carbon composite and platinum in order to analyze their effect on the solar cell efficiency. Four-point probe measurement revealed that the carbon composite exhibited slightly higher conductivity with a sheet resistance of 9.8 Ω/sq and 10.9 Ω/sq for carbon and platinum, respectively. Likewise, the photoconversion efficiency of the monolithic cells with carbon counter-electrode almost doubled the efficiency of the cells with platinum counter-electrode. Our results demonstrate that carbon could outperform the performance of platinum as catalytic material in monolithic DSSC.

  6. Preparation of organic-silica hybrid boronate affinity monolithic column for the specific capture and separation of cis-diol containing compounds.

    Science.gov (United States)

    Li, Qianjin; Lü, Chenchen; Li, Hengye; Liu, Yunchun; Wang, Heye; Wang, Xin; Liu, Zhen

    2012-09-21

    A new boronate-silica hybrid monolithic column was prepared using a one-pot approach with 3-acrylamidophenylboronic acid (AAPBA) as the boronate affinity ligand. The AAPBA-silica monolith exhibited several attractive advantages. First, it is highly hydrophilic, providing excellent specificity and avoiding the presence of organic solvent in the mobile phase. Second, due to its large surface area, it exhibited a high binding capacity, 49.5 μmol/mL, the highest among the boronate affinity monolithic columns appeared in the literature. Third, the monolith can bind with cis-diol containing compounds at pH as low as 6.5, which not only avoids the use of basic pH conditions at which the silica monolith may hydrolysis but also facilitates the applications to wider sample range. Finally, the hybrid monolithic column exhibited apparent secondary separation capability, which allows for two-dimensional (2D) separation of cis-diol compounds in a single column. Due to these merits, the AAPBA-silica hybrid monolithic column can be a promising separation medium for the analysis of cis-diol containing compounds. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Monolithic Superconducting Emitter of Tunable Circularly Polarized Terahertz Radiation

    Science.gov (United States)

    Elarabi, A.; Yoshioka, Y.; Tsujimoto, M.; Kakeya, I.

    2017-12-01

    We propose an approach to controlling the polarization of terahertz (THz) radiation from intrinsic Josephson-junction stacks in a single crystalline high-temperature superconductor Bi2Sr2CaCu2O8 . Monolithic control of the surface high-frequency current distributions in the truncated square mesa structure allows us to modulate the polarization of the emitted terahertz wave as a result of two orthogonal fundamental modes excited inside the mesa. Highly polarized circular terahertz waves with a degree of circular polarization of more than 99% can be generated using an electrically controlled method. The intuitive results obtained from the numerical simulation based on the conventional antenna theory are consistent with the observed emission characteristics.

  8. Highly tailorable thiol-ene based emulsion-templated monoliths

    DEFF Research Database (Denmark)

    Lafleur, J. P.; Kutter, J. P.

    2014-01-01

    The attractive surface properties of thiol-ene polymers combined with their ease of processing make them ideal substrates in many bioanalytical applications. We report the synthesis of highly tailorable emulsion-templated porous polymers and beads in microfluidic devices based on off-stoichiometr......The attractive surface properties of thiol-ene polymers combined with their ease of processing make them ideal substrates in many bioanalytical applications. We report the synthesis of highly tailorable emulsion-templated porous polymers and beads in microfluidic devices based on off......-stoichiometry thiolene chemistry. The method allows monolith synthesis and anchoring inside thiol-ene microchannels in a single step. Variations in the monomer stoichiometric ratios and/or amount of porogen used allow for the creation of extremely varied polymer morphologies, from foam-like materials to dense networks...

  9. 1060-nm Tunable Monolithic High Index Contrast Subwavelength Grating VCSEL

    DEFF Research Database (Denmark)

    Ansbæk, Thor; Chung, Il-Sug; Semenova, Elizaveta

    2013-01-01

    We present the first tunable vertical-cavity surface-emitting laser (VCSEL) where the top distributed Bragg reflector has been completely substituted by an air-cladded high-index-contrast subwavelength grating (HCG) mirror. In this way, an extended cavity design can be realized by reducing...... the reflection at the semiconductor #x2013;air interface using an anti-reflective coating (ARC). We demonstrate how the ARC can be integrated in a monolithic structure by oxidizing AlGaAs with high Al-content. The HCG VCSEL has the potential to achieve polarization stable single-mode output with high tuning...... efficiency. The HCG VCSEL shows a total tuning range of 16 nm around an emission wavelength of 1060 nm with 1-mW output power....

  10. Nondestructive characterization methods for monolithic solid oxide fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Ellingson, W.A.

    1993-01-01

    Monolithic solid oxide fuel cells (MSOFCS) represent a potential breakthrough in fuel cell technology, provided that reliable fabrication methods can be developed. Fabrication difficulties arise in several steps of the processing: First is the fabrication of uniform thin (305 {mu}m) single-layer and trilayer green tapes (the trilayer tapes of anode/electrolyte/cathode and anode/interconnect/cathode must have similar coefficients of thermal expansion to sinter uniformly and to have the necessary electrochemical properties); Second is the development of fuel and oxidant channels in which residual stresses are likely to develop in the tapes; Third is the fabrication of a ``complete`` cell for which the bond quality between layers and the quality of the trilayers must be established; and Last, attachment of fuel and oxidant manifolds and verification of seal integrity. Purpose of this report is to assess nondestructive characterization methods that could be developed for application to laboratory, prototype, and full-scale MSOFCs.

  11. Test of the TRAPPISTe monolithic detector system

    Science.gov (United States)

    Soung Yee, L.; Álvarez, P.; Martin, E.; Cortina, E.; Ferrer, C.

    2013-12-01

    A monolithic pixel detector named TRAPPISTe-2 has been developed in Silicon-on-Insulator (SOI) technology. A p-n junction is implanted in the bottom handle wafer and connected to readout electronics integrated in the top active layer. The two parts are insulated from each other by a buried oxide layer resulting in a monolithic detector. Two small pixel matrices have been fabricated: one containing a 3-transistor readout and a second containing a charge sensitive amplifier readout. These two readout structures have been characterized and the pixel matrices were tested with an infrared laser source. The readout circuits are adversely affected by the backgate effect, which limits the voltage that can be applied to the metal back plane to deplete the sensor, thus narrowing the depletion width of the sensor. Despite the low depletion voltages, the integrated pixel matrices were able to respond to and track a laser source.

  12. Monolithic pixel detectors for high energy physics

    CERN Document Server

    Snoeys, W

    2013-01-01

    Monolithic pixel detectors integrating sensor matrix and readout in one piece of silicon have revolutionized imaging for consumer applications, but despite years of research they have not yet been widely adopted for high energy physics. Two major requirements for this application, radiation tolerance and low power consumption, require charge collection by drift for the most extreme radiation levels and an optimization of the collected signal charge over input capacitance ratio ( Q / C ). It is shown that monolithic detectors can achieve Q / C for low analog power consumption and even carryout the promise to practically eliminate analog power consumption, but combining suf fi cient Q / C , collection by drift, and integration of readout circuitry within the pixel remains a challenge. An overview is given of different approaches to address this challenge, with possible advantages and disadvantages.

  13. Monolithically Integrated Fiber Optic Coupler

    Science.gov (United States)

    2013-01-14

    single fused fiber 52 and drawn into ferrule 54 in order to provide an output as a photonic crystal fiber (PCF) or photonic bandgap ( PBG ) fiber 56...the reduced diameter air-silica photonic crystal fiber 56 (PCF) or photonic band gap ( PBG ), which is connected by a continuous transition of the... PBG 56 with a negative index of refraction includes metamaterials of superlattices formed by metal nanoparticles. The binary superlattices are

  14. Update On Monolithic Fuel Fabrication Development

    Energy Technology Data Exchange (ETDEWEB)

    C. R Clark; J. M. Wight; G. C. Knighton; G. A. Moore; J. F. Jue

    2005-11-01

    Efforts to develop a viable monolithic research reactor fuel plate have continued at Idaho National Laboratory. These efforts have concentrated on both fabrication process refinement and scale-up to produce full sized fuel plates. Advancements have been made in the production of U-Mo foil including full sized foils. Progress has also been made in the friction stir welding and transient liquid phase bonding fabrication processes resulting in better bonding, more stable processes and the ability to fabricate larger fuel plates.

  15. FLUIDIZED BED STEAM REFORMER MONOLITH FORMATION

    Energy Technology Data Exchange (ETDEWEB)

    Jantzen, C

    2006-12-22

    Fluidized Bed Steam Reforming (FBSR) is being considered as an alternative technology for the immobilization of a wide variety of aqueous high sodium containing radioactive wastes at various DOE facilities in the United States. The addition of clay, charcoal, and a catalyst as co-reactants converts aqueous Low Activity Wastes (LAW) to a granular or ''mineralized'' waste form while converting organic components to CO{sub 2} and steam, and nitrate/nitrite components, if any, to N{sub 2}. The waste form produced is a multiphase mineral assemblage of Na-Al-Si (NAS) feldspathoid minerals with cage-like structures that atomically bond radionuclides like Tc-99 and anions such as SO{sub 4}, I, F, and Cl. The granular product has been shown to be as durable as LAW glass. Shallow land burial requires that the mineralized waste form be able to sustain the weight of soil overburden and potential intrusion by future generations. The strength requirement necessitates binding the granular product into a monolith. FBSR mineral products were formulated into a variety of monoliths including various cements, Ceramicrete, and hydroceramics. All but one of the nine monoliths tested met the <2g/m{sup 2} durability specification for Na and Re (simulant for Tc-99) when tested using the Product Consistency Test (PCT; ASTM C1285). Of the nine monoliths tested the cements produced with 80-87 wt% FBSR product, the Ceramicrete, and the hydroceramic produced with 83.3 wt% FBSR product, met the compressive strength and durability requirements for an LAW waste form.

  16. Peculiarities of Thermal Treatment of Monolithic Reinforced Concrete Structures

    Science.gov (United States)

    Kuchin, V. N.; Shilonosova, N. V.

    2017-11-01

    A mathematical program has been developed that allows one to determine the parameters of heat treatment of monolithic structures. One of the quality indicators of monolithic reinforced concrete structures is the level of temperature stresses arising in the process of heat treatment and further operation of structures. In winter at heat treatment the distribution of temperatures along the cross-section of the structure is uneven. A favorable thermo-stressed state in a concrete massif occurs when using the preheating method, providing the concrete temperature in the center of the structure is greater than at the periphery. In this case, after the strength is set and the temperature is later equalized along the cross-section, the central part of the structure tends to decrease its dimensions more but the extreme zones prevent it. Therefore, the center is in a state of tension, and the extreme zones on the periphery are compressed. In compressed concrete there is a lesser chance of cracks or defects. The temperature gradient over the section of the structure, the stress in the concrete and its strength are determined. When calculating the temperature and strength fields, the stress level was determined - a value equal to the ratio of the tensile stresses in the section under consideration to the tensile strength of the concrete in this section at the same time. The nature of the change in stress level is determined by the massive structure and power of the formwork heaters. It is shown that under unfavorable conditions the stress level is close to the critical value. The greatest temperature gradient occurs in the outer layers adjacent to the heating formwork. A technology for concrete conditioning is proposed which makes it possible to reduce the temperature stresses along the cross-section of the structure. The time for concrete conditioning in the formwork is reduced. In its turn, it further reduces labor costs and the cost of concrete work along with the cost of

  17. FRACTURE-RESISTANT MONOLITHIC DENTAL CROWNS

    Science.gov (United States)

    Zhang, Yu; Mai, Zhisong; Barani, Amir; Bush, Mark; Lawn, Brian

    2016-01-01

    Objective To quantify the splitting resistance of monolithic zirconia, lithium disilicate and nanoparticle-composite dental crowns. Methods Fracture experiments were conducted on anatomically-correct monolithic crown structures cemented to standard dental composite dies, by axial loading of a hard sphere placed between the cusps. The structures were observed in situ during fracture testing, and critical loads to split the structures were measured. Extended finite element modeling (XFEM), with provision for step-by-step extension of embedded cracks, was employed to simulate full failure evolution. Results Experimental measurements and XFEM predictions were self consistent within data scatter. In conjunction with a fracture mechanics equation for critical splitting load, the data were used to predict load-sustaining capacity for crowns on actual dentin substrates and for loading with a sphere of different size. Stages of crack propagation within the crown and support substrate were quantified. Zirconia crowns showed the highest fracture loads, lithium disilicate intermediate, and dental nanocomposite lowest. Dental nanocomposite crowns have comparable fracture resistance to natural enamel. Significance The results confirm that monolithic crowns are able to sustain high bite forces. The analysis indicates what material and geometrical properties are important in optimizing crown performance and longevity. PMID:26792623

  18. Fracture-resistant monolithic dental crowns.

    Science.gov (United States)

    Zhang, Yu; Mai, Zhisong; Barani, Amir; Bush, Mark; Lawn, Brian

    2016-03-01

    To quantify the splitting resistance of monolithic zirconia, lithium disilicate and nanoparticle-composite dental crowns. Fracture experiments were conducted on anatomically-correct monolithic crown structures cemented to standard dental composite dies, by axial loading of a hard sphere placed between the cusps. The structures were observed in situ during fracture testing, and critical loads to split the structures were measured. Extended finite element modeling (XFEM), with provision for step-by-step extension of embedded cracks, was employed to simulate full failure evolution. Experimental measurements and XFEM predictions were self-consistent within data scatter. In conjunction with a fracture mechanics equation for critical splitting load, the data were used to predict load-sustaining capacity for crowns on actual dentin substrates and for loading with a sphere of different size. Stages of crack propagation within the crown and support substrate were quantified. Zirconia crowns showed the highest fracture loads, lithium disilicate intermediate, and dental nanocomposite lowest. Dental nanocomposite crowns have comparable fracture resistance to natural enamel. The results confirm that monolithic crowns are able to sustain high bite forces. The analysis indicates what material and geometrical properties are important in optimizing crown performance and longevity. Copyright © 2015 Academy of Dental Materials. All rights reserved.

  19. Metal oxide nanorod arrays on monolithic substrates

    Energy Technology Data Exchange (ETDEWEB)

    Gao, Pu-Xian; Guo, Yanbing; Ren, Zheng

    2018-01-02

    A metal oxide nanorod array structure according to embodiments disclosed herein includes a monolithic substrate having a surface and multiple channels, an interface layer bonded to the surface of the substrate, and a metal oxide nanorod array coupled to the substrate surface via the interface layer. The metal oxide can include ceria, zinc oxide, tin oxide, alumina, zirconia, cobalt oxide, and gallium oxide. The substrate can include a glass substrate, a plastic substrate, a silicon substrate, a ceramic monolith, and a stainless steel monolith. The ceramic can include cordierite, alumina, tin oxide, and titania. The nanorod array structure can include a perovskite shell, such as a lanthanum-based transition metal oxide, or a metal oxide shell, such as ceria, zinc oxide, tin oxide, alumina, zirconia, cobalt oxide, and gallium oxide, or a coating of metal particles, such as platinum, gold, palladium, rhodium, and ruthenium, over each metal oxide nanorod. Structures can be bonded to the surface of a substrate and resist erosion if exposed to high velocity flow rates.

  20. An overview of monolithic zirconia in dentistry

    Directory of Open Access Journals (Sweden)

    Özlem Malkondu

    2016-07-01

    Full Text Available Zirconia restorations have been used successfully for years in dentistry owing to their biocompatibility and good mechanical properties. Because of their lack of translucency, zirconia cores are generally veneered with porcelain, which makes restorations weaker due to failure of the adhesion between the two materials. In recent years, all-ceramic zirconia restorations have been introduced in the dental sector with the intent to solve this problem. Besides the elimination of chipping, the reduced occlusal space requirement seems to be a clear advantage of monolithic zirconia restorations. However, scientific evidence is needed to recommend this relatively new application for clinical use. This mini-review discusses the current scientific literature on monolithic zirconia restorations. The results of in vitro studies suggested that monolithic zirconia may be the best choice for posterior fixed partial dentures in the presence of high occlusal loads and minimal occlusal restoration space. The results should be supported with much more in vitro and particularly in vivo studies to obtain a final conclusion.

  1. Chromatographic selectivity of poly(alkyl methacrylate-co-divinylbenzene) monolithic columns for polar aromatic compounds by pressure-driven capillary liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Shu-Ling; Wang, Chih-Chieh; Fuh, Ming-Ren, E-mail: msfuh@scu.edu.tw

    2016-10-05

    In this study, divinylbenzene (DVB) was used as the cross-linker to prepare alkyl methacrylate (AlMA) monoliths for incorporating π-π interactions between the aromatic analytes and AlMA-DVB monolithic stationary phases in capillary LC analysis. Various AlMA/DVB ratios were investigated to prepare a series of 30% AlMA-DVB monolithic stationary phases in fused-silica capillaries (250-μm i.d.). The physical properties (such as porosity, permeability, and column efficiency) of the synthesized AlMA-DVB monolithic columns were investigated for characterization. Isocratic elution of phenol derivatives was first employed to evaluate the suitability of the prepared AlMA-DVB columns for small molecule separation. The run-to-run (0.16–1.20%, RSD; n = 3) and column-to-column (0.26–2.95%, RSD; n = 3) repeatabilities on retention times were also examined using the selected AlMA-DVB monolithic columns. The π-π interactions between the aromatic ring and the DVB-based stationary phase offered better recognition on polar analytes with aromatic moieties, which resulted in better separation resolution of aromatic analytes on the AlMA-DVB monolithic columns. In order to demonstrate the capability of potential environmental and/or food safety applications, eight phenylurea herbicides with single benzene ring and seven sulfonamide antibiotics with polyaromatic moieties were analyzed using the selected AlMA-DVB monolithic columns. - Highlights: • First investigation on chromatographic selectivity of AlMA-DVB monolithic columns. • Good run-to-run/column-to-column repeatability (<3%) on AlMA-DVB monolithic columns. • Efficient separation of phenylurea herbicides and sulfonamides on AlMA-DVB columns.

  2. Simplified Monolithic Flow Cytometer Chip With Three-Dimensional Hydrodyanmic Focusing And Integrated Fiber-Free Optics

    DEFF Research Database (Denmark)

    Motosuke, Masahiro; Jensen, Thomas Glasdam; Zhuang, Guisheng

    2011-01-01

    optical fibers in a monolithic architecture fabricated by a single photolithographic process. The vertical flow focusing is achieved by the optimized inlet geometry in a PDMS lid onto the substrate with detection channel and integrated optics. The simplified approach indicates the possibility...

  3. Immobilized monolithic enzyme reactors for application in proteomics and pharmaceutics.

    Science.gov (United States)

    Spross, Jens; Sinz, Andrea

    2009-11-01

    The use of monolithic supports for a wide variety of applications has rapidly expanded during the past few years. The examples for applications of monoliths presented herein show that the chromatographic performance of bioreactors and affinity media prepared from monolithic media is superior to that of conventional particle-based systems. The ease of fabrication and modification combined with the long lifetime of the monolithic columns and their potential to be used in fully automated analytical systems make them attractive tools for an increasing number of applications.

  4. [The use of peripherally inserted central catheter (PICC) in patients with hematological malignancies--a single center experience].

    Science.gov (United States)

    Mitrović, Zdravko; Komljenović, Igor; Jaksic, Ozren; Prka, Zeljko; Crnek, Sandra Sestan; Stojsavljević, Radmila Ajduković; Pirsic, Mario; Haris, Visnja; Kusec, Rajko; Dautovic, Diana; Pejsa, Vlatko

    2014-01-01

    AIM. In this study we presented our experience with peripherally inserted central venous catheter (PICC) in patients with hematological malignancies. In the period from 2009 to 2012, a total of 105 PICCs were inserted in 90 patients. Patients with Non-Hodgkin lymphoma treated with DA-EPOCH comprised almost 40% of the cohort. The total PICC in-dwell time was 14781 days with a median of 129 days (range 8-570 days). Malposition of the PICC occurred in 12 patients (11.4%) with a successful reposition or re-insertion. In 39 patients (37%) PICC was removed before the end of treatment due to suspected or proven infection (30 patients, 29%; 2.03 per 1000 PICC days), thrombosis associated with PICC in four patients (3.8%), occlusion of the PICC (two patients), misplaced catheter (two patients), and suspected thromboembolism in a single patient. PICC is a safe and convenient long-term venous access in patients with hematological malignancies.

  5. Estimation of a respiratory signal from a single-lead ECG using the 4th order central moments

    Directory of Open Access Journals (Sweden)

    Schmidt Marcus

    2015-09-01

    Full Text Available For a variety of clinical applications like magnetic resonance imaging (MRI the monitoring of vital signs is a common standard in clinical daily routine. Besides the electrocardiogram (ECG, the respiratory activity is an important vital parameter and might reveal pathological changes. Thoracic movement and the resulting impedance change between ECG electrodes enable the estimation of the respiratory signal from the ECG. This ECG-derived respiration (EDR can be used to calculate the breathing rate without the need for additional devices or monitoring modules. In this paper a new method is presented to estimate the respiratory signal from a single-lead ECG. The 4th order central moments was used to estimate the EDR signal exploiting the change of the R-wave slopes induced by respiration. This method was compared with two approaches by analyzing the Fantasia database from www.physionet.org. Furthermore, the ECG signals of 24 healthy subjects placed in an 3 T MR-scanner were acquired.

  6. Zinc tin oxide as high-temperature stable recombination layer for mesoscopic perovskite/silicon monolithic tandem solar cells

    KAUST Repository

    Werner, Jérémie

    2016-12-05

    Perovskite/crystalline silicon tandem solar cells have the potential to reach efficiencies beyond those of silicon single-junction record devices. However, the high-temperature process of 500 °C needed for state-of-the-art mesoscopic perovskite cells has, so far, been limiting their implementation in monolithic tandem devices. Here, we demonstrate the applicability of zinc tin oxide as a recombination layer and show its electrical and optical stability at temperatures up to 500 °C. To prove the concept, we fabricate monolithic tandem cells with mesoscopic top cell with up to 16% efficiency. We then investigate the effect of zinc tin oxide layer thickness variation, showing a strong influence on the optical interference pattern within the tandem device. Finally, we discuss the perspective of mesoscopic perovskite cells for high-efficiency monolithic tandem solar cells. © 2016 Author(s)

  7. A High Resolution Monolithic Crystal, DOI, MR Compatible, PET Detector

    Energy Technology Data Exchange (ETDEWEB)

    Robert S Miyaoka

    2012-03-06

    The principle objective of this proposal is to develop a positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning capability that will achieve state of the art spatial resolution and sensitivity performance for small animal PET imaging. When arranged in a ring or box detector geometry, the proposed detector module will support <1 mm3 image resolution and >15% absolute detection efficiency. The detector will also be compatible with operation in a MR scanner to support simultaneous multi-modality imaging. The detector design will utilize a thick, monolithic crystal scintillator readout by a two-dimensional array of silicon photomultiplier (SiPM) devices using a novel sensor on the entrance surface (SES) design. Our hypothesis is that our single-ended readout SES design will provide an effective DOI positioning performance equivalent to more expensive dual-ended readout techniques and at a significantly lower cost. Our monolithic crystal design will also lead to a significantly lower cost system. It is our goal to design a detector with state of the art performance but at a price point that is affordable so the technology can be disseminated to many laboratories. A second hypothesis is that using SiPM arrays, the detector will be able to operate in a MR scanner without any degradation in performance to support simultaneous PET/MR imaging. Having a co-registered MR image will assist in radiotracer localization and may also be used for partial volume corrections to improve radiotracer uptake quantitation. The far reaching goal of this research is to develop technology for medical research that will lead to improvements in human health care.

  8. Selective oxidation of cyclohexene through gold functionalized silica monolith microreactors

    Science.gov (United States)

    Alotaibi, Mohammed T.; Taylor, Martin J.; Liu, Dan; Beaumont, Simon K.; Kyriakou, Georgios

    2016-04-01

    Two simple, reproducible methods of preparing evenly distributed Au nanoparticle containing mesoporous silica monoliths are investigated. These Au nanoparticle containing monoliths are subsequently investigated as flow reactors for the selective oxidation of cyclohexene. In the first strategy, the silica monolith was directly impregnated with Au nanoparticles during the formation of the monolith. The second approach was to pre-functionalize the monolith with thiol groups tethered within the silica mesostructure. These can act as evenly distributed anchors for the Au nanoparticles to be incorporated by flowing a Au nanoparticle solution through the thiol functionalized monolith. Both methods led to successfully achieving even distribution of Au nanoparticles along the length of the monolith as demonstrated by ICP-OES. However, the impregnation method led to strong agglomeration of the Au nanoparticles during subsequent heating steps while the thiol anchoring procedure maintained the nanoparticles in the range of 6.8 ± 1.4 nm. Both Au nanoparticle containing monoliths as well as samples with no Au incorporated were tested for the selective oxidation of cyclohexene under constant flow at 30 °C. The Au free materials were found to be catalytically inactive with Au being the minimum necessary requirement for the reaction to proceed. The impregnated Au-containing monolith was found to be less active than the thiol functionalized Au-containing material, attributable to the low metal surface area of the Au nanoparticles. The reaction on the thiol functionalized Au-containing monolith was found to depend strongly on the type of oxidant used: tert-butyl hydroperoxide (TBHP) was more active than H2O2, likely due to the thiol induced hydrophobicity in the monolith.

  9. Clinical study on the success of posterior monolithic zirconia crowns and fixed dental prostheses: preliminary report

    Directory of Open Access Journals (Sweden)

    Merve Bankoğlu Güngör

    2017-09-01

    Full Text Available Objective: The purpose of this report was to present preliminary clinical results regarding the success rates and technical outcomes of posterior monolithic zirconia single tooth crowns (STs and fixed dental prostheses (FDPs. Materials and Method: Thirty-four patients received 43 posterior monolithic zirconia restorations as single tooth crowns (STs and/or fixed dental prostheses (FDPs, which were fabricated using a CAD-CAM (Computer Aided Design - Computer Aided Manufacturing system. At baseline and every 6 months, the restorations were examined for survival and technical outcomes. Success of the restorations was defined as the restoration remaining in situ, with no need for removal or replacement at follow-up visits. Technical outcomes were evaluated with a modified version of the United States Public Health Services criteria. Survival of restorations was estimated by using the Kaplan-Meier survival analysis. For each restoration, duration of follow-up was calculated from the time of placement to the date of its first failure. Results: After a mean observation period of 18.6 ± 3.9 months (between 8-24 months, cumulative survival rates were 86.7% and 92.3% for STs and FDPs, respectively. Technical evaluation revealed good marginal adaptation and crown contours; however, modifications were needed for shade and occlusion of restorations. Conclusion: These preliminary results revealed high survival rate and generally successful technical outcomes for posterior monolithic zirconia STs and FDPs.

  10. Large-scale single incised valley from a small catchment basin on the western Adriatic margin (central Mediterranean Sea)

    Science.gov (United States)

    Maselli, Vittorio; Trincardi, Fabio

    2013-01-01

    The Manfredonia Incised Valley (MIV) is a huge erosional feature buried below the Apulian shelf, on the western side of the Adriatic margin. The incision extends more than 60 km eastward, from the Tavoliere Plain to the outer shelf, not reaching the shelf edge. High-resolution chirp sonar profiles allow reconstruction of the morphology of the incision and its correlation at regional scale. The MIV records a single episode of incision, induced by the last glacial-interglacial sea level fall that forced the rivers draining the Tavoliere Plain to advance basinward, reaching their maximum extent at the peak of the Last Glacial Maximum. The valley was filled during a relatively short interval of about 10,000 yr during the Late Pleistocene-Holocene sea level rise and almost leveled-off at the time of maximum marine ingression, possibly recording the short-term climatic fluctuations that occurred. The accommodation space generated by the lowstand incision was exploited during the following interval of sea level rise by very high rates of sediment supply that allowed the preservation of up to 45 m of valley fill. High-resolution chirp sonar profiles highlight stratal geometries that are consistent with a typical transgressive valley fill of an estuary environment, including bay-head deltas, central basin and distal barrier-island deposits, organized in a backstepping configuration. The highest complexity of the valley fill is reached in the shallowest and most proximal area, where a kilometric prograding wedge formed during a period dominated by riverine input, possibly connected to high precipitation rates. Based on the depth of the valley margins during this interval, the fill was likely isochronous with the formation of sapropel S1 in the Mediterranean region and may have recorded significant fluctuations within the hydrological cycle.

  11. New progress on monolithic X-ray lens in diffraction application

    International Nuclear Information System (INIS)

    Li Yude; He Yejun; Chen Jun; Luo Ping; Wang Dachun; Yan Yiming

    1999-12-01

    The basic physical properties for monolithic X-ray lens are introduced. The X-ray diffraction for macromolecular crystallography using monolithic X-ray lens were investigated. The experimental results show that in the same X-ray source power the diffracted intensity in the condition with X-ray lens was increased about 7 times, and the resolution was improved by 0.2 x 10 -10 -0.6 x 10 -10 m. The signal to noise ratio was also improved, and the time of measurement was reduced. The X-ray diffraction of Au thin films on the Si(100) single crystal substrates were investigated in a X-ray powder diffractometer. The experimental results show that in the same X-ray source power the diffracted intensity in the condition with X-ray lens was increased about 2 times, and the angular resolution of the diffractometer was enhanced

  12. Regional waste treatment facilities with underground monolith disposal for all low-heat-generating nuclear wastes

    International Nuclear Information System (INIS)

    Forsberg, C.W.

    1982-01-01

    An alternative system for treatment and disposal of all ''low-heat-generating'' nuclear wastes from all sources is proposed. The system, Regional Waste Treatment Facilities with Underground Monolith Disposal (RWTF/UMD), integrates waste treatment and disposal operations into single facilities at regional sites. Untreated and/or pretreated wastes are transported from generation sites such as reactors, hospitals, and industries to regional facilities in bulk containers. Liquid wastes are also transported in bulk after being gelled for transport. The untreated and pretreated wastes are processed by incineration, crushing, and other processes at the RWTF. The processed wastes are mixed with cement. The wet concrete mixture is poured into large low-cost, manmade caverns or deep trenches. Monolith dimensions are from 15 to 25 m wide, and 20 to 60 m high and as long as required. This alternative waste system may provide higher safety margins in waste disposal at lower costs

  13. Development of a Monolithic Research Reactor Fuel Type at Argonne National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Clark, C.R.; Briggs, R.J.

    2004-10-06

    The Reduced Enrichment for Research and Test Reactors (RERTR) program has been tasked with the conversion of research reactors from highly enriched to low-enriched uranium (LEU). To convert several high power reactors, monolithic fuel, a new fuel type, is being developed. This fuel type replaces the standard fuel dispersion with a fuel alloy foil, which allows for fuel densities far in excess of that found in dispersion fuel. The single-piece fuel foil also contains a significantly lower interface area between the fuel and the aluminum in the plate than the standard fuel type, limiting the amount of detrimental fuel-aluminum interaction that can occur. Implementation of monolithic fuel is dependant on the development of a suitable fabrication method as traditional roll-bonding techniques are inadequate.

  14. Validation and perspectives of a femtosecond laser fabricated monolithic optical stretcher

    Science.gov (United States)

    Bellini, Nicola; Bragheri, Francesca; Cristiani, Ilaria; Guck, Jochen; Osellame, Roberto; Whyte, Graeme

    2012-01-01

    The combination of high power laser beams with microfluidic delivery of cells is at the heart of high-throughput, single-cell analysis and disease diagnosis with an optical stretcher. So far, the challenges arising from this combination have been addressed by externally aligning optical fibres with microfluidic glass capillaries, which has a limited potential for integration into lab-on-a-chip environments. Here we demonstrate the successful production and use of a monolithic glass chip for optical stretching of white blood cells, featuring microfluidic channels and optical waveguides directly written into bulk glass by femtosecond laser pulses. The performance of this novel chip is compared to the standard capillary configuration. The robustness, durability and potential for intricate flow patterns provided by this monolithic optical stretcher chip suggest its use for future diagnostic and biotechnological applications. PMID:23082304

  15. Stellan Hjertén’s contribution to the development of monolithic stationary phases

    Science.gov (United States)

    Svec, Frantisek

    2009-01-01

    This overview is presented to celebrate birthday of one of the luminaries of the separation science and my friend – Stellan Hjertén. He made significant contributions to a variety of areas in the separation science such as electrophoresis, liquid chromatography, and capillary electrochromatography to name just a few. Since the scope of his work was enormous, this review will focus only on a single aspect of his scientific activities, design and applications of monolithic materials. During the years starting from 1989, Stellan Hjertén published many excellent papers concerning the preparation of acrylamide chemistry-based monoliths and their use in both micro-HPLC and capillary electrochromatography. The following text details his works in field. PMID:18383033

  16. Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow.

    Science.gov (United States)

    Jiang, Peng; Zhao, Shuai; Zhu, Rong

    2015-12-15

    This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system.

  17. Fine-grain concrete from mining waste for monolithic construction

    Science.gov (United States)

    Lesovik, R. V.; Ageeva, M. S.; Lesovik, G. A.; Sopin, D. M.; Kazlitina, O. V.; Mitrokhin, A. A.

    2018-03-01

    The technology of a monolithic construction is a well-established practice among most Russian real estate developers. The strong points of the technology are low cost of materials and lower demand for qualified workers. The monolithic construction uses various types of reinforced slabs and foamed concrete, since they are easy to use and highly durable; they also need practically no additional treatment.

  18. Applications of monolithic silica capillary columns in proteomics

    NARCIS (Netherlands)

    Barroso, B.; Lubda, D; Bischoff, Rainer

    2003-01-01

    The use and applicability of silica based capillary monolithic reversed-phase columns in proteomic analysis has been evaluated by liquid chromatography-mass spectrometry (LC-MS). Chromatographic performance of the monolithic capillaries was evaluated with a tryptic digest of cytochrome C showing

  19. Time-based position estimation in monolithic scintillator detectors

    NARCIS (Netherlands)

    Tabacchini, V.; Borghi, G.; Schaart, D.R.

    2015-01-01

    Gamma-ray detectors based on bright monolithic scintillation crystals coupled to pixelated photodetectors are currently being considered for several applications in the medical imaging field. In a typical monolithic detector, both the light intensity and the time of arrival of the earliest

  20. A novel photocatalytic monolith reactor for multiphase heterogeneous photocatalysis

    NARCIS (Netherlands)

    Du, P.; Carneiro, J.T.; Moulijn, J.A.; Mul, Guido

    2008-01-01

    A novel reactor for multi-phase photocatalysis is presented, the so-called internally illuminated monolith reactor (IIMR). In the concept of the IIMR, side light emitting fibers are placed inside the channels of a ceramic monolith, equipped with a TiO2 photocatalyst coated on the wall of each

  1. Hydrogel coated monoliths for enzymatic hydrolysis of penicillin G

    NARCIS (Netherlands)

    De Lathouder, K.M.; Smeltink, M.W.; Straathof, A.J.J.; Paasman, M.A.; Van de Sandt, E.J.A.X.; Kapteijn, F.; Moulijn, J.A.

    2008-01-01

    The objective of this work was to develop a hydrogel-coated monolith for the entrapment of penicillin G acylase (E. coli, PGA). After screening of different hydrogels, chitosan was chosen as the carrier material for the preparation of monolithic biocatalysts. This protocol leads to active

  2. Energy Absorption of Monolithic and Fibre Reinforced Aluminium Cylinders

    NARCIS (Netherlands)

    De Kanter, J.L.C.G.

    2006-01-01

    Summary accompanying the thesis: Energy Absorption of Monolithic and Fibre Reinforced Aluminium Cylinders by Jens de Kanter This thesis presents the investigation of the crush behaviour of both monolithic aluminium cylinders and externally fibre reinforced aluminium cylinders. The research is based

  3. Monolithic LTCC seal frame and lid

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, Daniel S.; Peterson, Kenneth A.; Stockdale, Dave; Duncan, James Brent; Riggs, Bristen

    2016-06-21

    A method for forming a monolithic seal frame and lid for use with a substrate and electronic circuitry comprises the steps of forming a mandrel from a ceramic and glass based material, forming a seal frame and lid block from a ceramic and glass based material, creating a seal frame and lid by forming a compartment and a plurality of sidewalls in the seal frame and lid block, placing the seal frame and lid on the mandrel such that the mandrel fits within the compartment, and cofiring the seal frame and lid block.

  4. FLUIDIZED BED STEAM REFORMER (FBSR) PRODUCT: MONOLITH FORMATION AND CHARACTERIZATION

    Energy Technology Data Exchange (ETDEWEB)

    Jantzen, C

    2006-09-13

    The most important requirement for Hanford's low activity waste (LAW) form for shallow land disposal is the chemical durability of the product. A secondary, but still essential specification, is the compressive strength of the material with regards to the strength of the material under shallow land disposal conditions, e.g. the weight of soil overburden and potential intrusion by future generations, because the term ''near-surface disposal'' indicates disposal in the uppermost portion, or approximately the top 30 meters, of the earth's surface. The THOR{reg_sign} Treatment Technologies (TTT) mineral waste form for LAW is granular in nature because it is formed by Fluidized Bed Steam Reforming (FBSR). As a granular product it has been shown to be as durable as Hanford's LAW glass during testing with ASTM C-1285-02 known as the Product Consistency Test (PCT) and with the Single Pass Flow Through Test (SPFT). Hanford Envelope A and Envelope C simulants both performed well during PCT and SPFT testing and during subsequent performance assessment modeling. This is partially due to the high aluminosilicate content of the mineral product which provides a natural aluminosilicate buffering mechanism that inhibits leaching and is known to occur in naturally occurring aluminosilicate mineral analogs. In order for the TTT Na-Al-Si (NAS) granular mineral product to meet the compressive strength requirements (ASTM C39) for a Hanford waste form, the granular product needs to be made into a monolith or disposed of in High Integrity Containers (HIC's). Additionally, the Hanford intruder scenario for disposal in the Immobilized Low Activity Waste (ILAW) trench is mitigated as there is reduced intruder exposure when a waste form is in a monolithic form. During the preliminary testing of a monolith binder for TTT's FBSR mineral product, four parameters were monitored: (1) waste loading (not optimized for each waste form tested); (2) density

  5. Applications of silica-based monolithic HPLC columns.

    Science.gov (United States)

    Cabrera, Karin

    2004-07-01

    The recent invention and successive commercial introduction of monolithic silica columns has motivated many scientists from both academia and industry to study their use in HPLC. The first paper on monolithic silica columns appeared in 1996. Currently about 200 papers have been published relating to applications and characterization of monolithic silica columns, including monolithic capillaries. This review attempts to give an overview covering various aspects of this new column type in the field of high throughput analysis of drugs and metabolites, chiral separations, analysis of pollutants and food-relevant compounds, as well as in bioanalytical separations such as in proteomics. Some of the applications are described in greater detail. The numerous publications dealing with the physicochemical and chromatographic characterization of monolithic silica columns are briefly summarized.

  6. Less common applications of monoliths: V. Monolithic scaffolds modified with nanostructures for chromatographic separations and tissue engineering.

    Science.gov (United States)

    Krenkova, Jana; Foret, Frantisek; Svec, Frantisek

    2012-06-01

    Scaffolds modified with nanostructures are recently finding use in a broad range of applications spanning from chromatographic separations to tissue engineering. This continuation of the review series on design and applications of monolithic materials covers some of the less common monoliths including use of nanostructures in preparation, modifications, and applications. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. The preparation of a poly (pentaerythritol tetraglycidyl ether-co-poly ethylene imine) organic monolithic capillary column and its application in hydrophilic interaction chromatography for polar molecules.

    Science.gov (United States)

    Chen, Ye; Shu, Yan; Yang, Zihui; Lv, Xumei; Tan, Wangming; Chen, Yingzhuang; Ma, Ming; Chen, Bo

    2017-10-02

    An easy single-step thermal treatment "one-pot" approach for the preparation of poly (pentaerythritol tetraglycidyl ether-co-poly ethylene imine) organic monolithic capillary columns was developed successfully. The column was prepared by the epoxy-amine ring-opening polymerization of pentaerythritol tetraglycidyl ether (PTE) with poly (ethylene imine) (PEI) using acetonitrile (ACN) and polyethylene glycol 600 (PEG 600) as the porogenic system at 60 °C for 12 h. The obtained monolith was homogeneous and permeable. It achieved the high-efficiency separation of polar molecules including amides, nucleosides, bases, phenols, and benzoic acids in capillary liquid chromatography (cLC). The highest column efficiency reached ca. 101,000 plates/m (for guanine) on monolith poly(PTE-co-PEI) at 0.64 mm/s, and satisfactory chromatographic performance with column efficiencies ranged from 45,500 to 97,000 plates/m was achieved for the four amides. A typical hydrophilic interaction liquid chromatography (HILIC) retention mechanism was observed with high organic solvent contents (>60% ACN). Also, the polymer-based monolithic column was successfully applied to separate the tumor markers. Furthermore, the poly(PTE-co-PEI) monolith could be easily modified with 1, 2-epoxydodecane, which reacted with the amino groups presented on the surface of the poly(PTE-co-PEI) monolith. Hydrophobic interactions were observed during the separation of alkylbenzenes and anilines on the post-modified poly(PTE-co-PEI) monolith. Together, these results confirm the feasibility of the epoxy-amine ring-opening polymerization reaction during the fabrication of a monolithic column with high efficiency for cLC applications. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Catastrophic failure of a monolithic zirconia prosthesis.

    Science.gov (United States)

    Chang, Jae-Seung; Ji, Woon; Choi, Chang-Hoon; Kim, Sunjai

    2015-02-01

    Recently, monolithic zirconia restorations have received attention as an alternative to zirconia veneered with feldspathic porcelain to eliminate chipping failures of veneer ceramics. In this clinical report, a patient with mandibular edentulism received 4 dental implants in the interforaminal area, and a screw-retained monolithic zirconia prosthesis was fabricated. The patient also received a maxillary complete removable dental prosthesis over 4 anterior roots. At the 18-month follow-up, all of the zirconia cylinders were seen to be fractured, and the contacting abutment surfaces had lost structural integrity. The damaged abutments were replaced with new abutments, and a new prosthesis was delivered with a computer-assisted design and computer-assisted manufacturing fabricated titanium framework with denture teeth and denture base resins. At the 6-month recall, the patient did not have any problems. Dental zirconia has excellent physical properties; however, care should be taken to prevent excessive stresses on the zirconia cylinders when a screw-retained zirconia restoration is planned as a definitive prosthesis. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  9. Aperture scaling effects with monolithic periodically poled lithium niobate optical parametric oscillators and generators.

    Science.gov (United States)

    Missey, M; Dominic, V; Powers, P; Schepler, K L

    2000-02-15

    We used elliptical beams to demonstrate aperture scaling effects in nanosecond single-grating and multigrating periodically poled lithium niobate (PPLN) monolithic optical parametric oscillators and generators. Increasing the cavity Fresnel number in single-grating crystals broadened both the beam divergence and the spectral bandwidth. Both effects are explained in terms of the phase-matching geometry. These effects are suppressed when a multigrating PPLN crystal is used because the individual gratings provide small effective subapertures. A flood-pumped multigrating optical parametric generator displayed a low output beam divergence and contained 19 pairs of signal and idler frequencies.

  10. Aerosol optical properties at Lampedusa (Central Mediterranean. 2. Determination of single scattering albedo at two wavelengths for different aerosol types

    Directory of Open Access Journals (Sweden)

    D. Meloni

    2006-01-01

    Full Text Available Aerosol optical properties were retrieved from direct and diffuse spectral irradiance measurements made by a multi-filter rotating shadowband radiometer (MFRSR at the island of Lampedusa (35.5° N, 12.6° E, in the Central Mediterranean, in the period July 2001–September 2003. In a companion paper (Pace et al., 2006 the aerosol optical depth (AOD and Ångström exponent were used together with airmass backward trajectories to identify and classify different aerosol types. The MFRSR diffuse-to-direct ratio (DDR at 415.6 nm and 868.7 nm for aerosol classified as 'biomass burning-urban/industrial', originating primarily from the European continent, and desert dust, originating from the Sahara, is used in this study to estimate the aerosol single scattering albedo (SSA. A detailed radiative transfer model is initialised with the measured aerosol optical depth; calculations are performed at the two wavelengths varying the SSA values until the modelled DDR matches the MFRSR observations. Sensitivity studies are performed to estimate how uncertainties on AOD, DDR, asymmetry factor (g, and surface albedo influence the retrieved SSA values. The results show that a 3% variation of AOD or DDR produce a change of about 0.02 in the retrieved SSA value at 415.6 and 868.7 nm; a ±0.06 variation of the asymmetry factor g produces a change of the estimated SSA of <0.04 at 415.6 nm, and <0.06 at 868.7 nm; finally, an increase of the assumed surface albedo of 0.05 causes very small changes (0.01–0.02 in the retrieved SSA. The calculations show that the SSA of desert dust (DD increases with wavelength, from 0.81±0.05 at 415.6 nm to 0.94±0.05 at 868.7 nm; on the contrary, the SSA of urban/industrial (UN aerosols decreases from 0.96±0.02 at 415.6 nm to 0.87±0.07 at 868.7 nm; the SSA of biomass burning (BB particles is 0.82±0.04 at 415.6 nm and 0.80±0.05 at 868.7 nm. Episodes of UN aerosols occur usually in June and July; long lasting BB aerosol episodes

  11. All-fiber high-power monolithic femtosecond laser at 1.59 µm with 63-fs pulse width

    Science.gov (United States)

    Hekmat, M. J.; Omoomi, M.; Gholami, A.; Yazdabadi, A. Bagheri; Abdollahi, M.; Hamidnejad, E.; Ebrahimi, A.; Normohamadi, H.

    2018-01-01

    In this research, by adopting an alternative novel approach to ultra-short giant pulse generation which basically originated from difficulties with traditional employed methods, an optimized Er/Yb co-doped double-clad fiber amplifier is applied to boost output average power of single-mode output pulses to a high level of 2-W at 1.59-µm central wavelength. Output pulses of approximately 63-fs pulse width at 52-MHz repetition rate are obtained in an all-fiber monolithic laser configuration. The idea of employing parabolic pulse amplification for stretching output pulses together with high-power pulse amplification using Er/Yb co-doped active fibers for compressing and boosting output average power plays crucial role in obtaining desired results. The proposed configuration enjoys massive advantages over previously reported literature which make it well-suited for high-power precision applications such as medical surgery. Detailed dynamics of pulse stretching and compressing in active fibers with different GVD parameters are numerically and experimentally investigated.

  12. Applications of methacrylate-based monolithic supports for speciation analysis.

    Science.gov (United States)

    Scancar, Janez; Milacic, Radmila

    2009-08-01

    Liquid chromatography combined with element specific detection is commonly applied in speciation analysis. In these analyses, to obtain reliable data chemical species should not be transformed. To preserve chemical species during the separation step, fast chromatographic procedures and mild separation conditions are required. Monolithic supports that enable rapid chromatographic separations have rarely been used in speciation analysis. Methacrylate-based anion- and cation-exchange monolithic supports offer separation of charged chemical species of elements and can be used as a complementary tool to particle-packed liquid chromatographic columns. The present paper presents an overview of successful applications of methacrylate-based monolithic supports in speciation of zinc (Zn), chromium (Cr), and aluminium (Al) in environmental, occupational health, and biological samples. Measures of analytical performance of convective interaction media (CIM) monolithic chromatographic supports, namely selectivity, sensitivity, and time of analysis, are compared to those of particle-packed columns. The potential of CIM monolithic chromatography in speciation analysis is critically discussed. Direct comparison of the experimental data in speciation of elements by ion-exchange monolithic and fast protein liquid chromatography is reported for the first time. Finally, some recommendations are given for further investigations of the potential of monolithic chromatography and its implementations in different fields of element speciation analysis.

  13. Influence of different carbon monolith preparation parameters on pesticide adsorption

    Directory of Open Access Journals (Sweden)

    Vukčević Marija

    2013-01-01

    Full Text Available The capacity of carbon monolith for pesticide removal from water, and the mechanism of pesticide interaction with carbon surface were examined. Different carbon monolith samples were obtained by varying the carbonization and activation parameters. In order to examine the role of surface oxygen groups in pesticide adsorption, carbon monolith surface was functionalized by chemical treatment in HNO3, H2O2 and KOH. The surface properties of the obtained samples were investigated by BET surface area, pore size distribution and temperature-programmed desorption. Adsorption of pesticides from aqueous solution onto activated carbon monolith samples was studied by using five pesticides belonging to different chemical groups (acetamiprid, dimethoate, nicosulfuron, carbofuran and atrazine. Presented results show that higher temperature of carbonization and the amount of activating agent allow obtaining microporous carbon monolith with higher amount of surface functional groups. Adsorption properties of the activated carbon monolith were more readily affected by the amount of the surface functional groups than by specific surface area. Results obtained by carbon monolith functionalisation showed that π-π interactions were the main force for adsorption of pesticides with aromatic structure, while acidic groups play an important role in adsorption of pesticides with no aromatic ring in the chemical structure.

  14. Biomimetic small peptide functionalized affinity monoliths for monoclonal antibody purification.

    Science.gov (United States)

    Wang, Xiangyu; Xia, Donghai; Han, Hai; Peng, Kun; Zhu, Peijie; Crommen, Jacques; Wang, Qiqin; Jiang, Zhengjin

    2018-08-09

    The rapid development of monoclonal antibodies (mAbs) in therapeutic and diagnostic applications has necessitated the advancement of mAbs purification technologies. In this study, a biomimetic small peptide ligand 3,5-di-tert-butyl-4-hydroxybenzoic acid-Arg-Arg-Gly (DAAG) functionalized monolith was fabricated through a metal ion chelation-based multi-step approach. The resulting monolith showed good chromatographic performance. Compared with the Ni 2+ based IMAC monolith, the DAAG functionalized monolith exhibited not only excellent specificity but also higher dynamic binding capacity (DBC). The 10% DBC and 50% DBC for hIgG reached as high values as 26.0 and 34.6 mg/mL, respectively, at a ligand density of 8.8 μmol/mL, due to the high porosity and accessibility of the monolithic matrix. Moreover, the stability of the DAAG functionalized monolith in successive breakthrough experiments indicates that it has a promising potential for long-term use in mAbs purification. Finally, the DAAG functionalized monolith was successfully applied to the purification of trastuzumab or human immunoglobulin G (hIgG) from biological samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Monolithic Chip for High-throughput Blood Cell Depletion to Sort Rare Circulating Tumor Cells.

    Science.gov (United States)

    Fachin, Fabio; Spuhler, Philipp; Martel-Foley, Joseph M; Edd, Jon F; Barber, Thomas A; Walsh, John; Karabacak, Murat; Pai, Vincent; Yu, Melissa; Smith, Kyle; Hwang, Henry; Yang, Jennifer; Shah, Sahil; Yarmush, Ruby; Sequist, Lecia V; Stott, Shannon L; Maheswaran, Shyamala; Haber, Daniel A; Kapur, Ravi; Toner, Mehmet

    2017-09-07

    Circulating tumor cells (CTCs) are a treasure trove of information regarding the location, type and stage of cancer and are being pursued as both a diagnostic target and a means of guiding personalized treatment. Most isolation technologies utilize properties of the CTCs themselves such as surface antigens (e.g., epithelial cell adhesion molecule or EpCAM) or size to separate them from blood cell populations. We present an automated monolithic chip with 128 multiplexed deterministic lateral displacement devices containing ~1.5 million microfabricated features (12 µm-50 µm) used to first deplete red blood cells and platelets. The outputs from these devices are serially integrated with an inertial focusing system to line up all nucleated cells for multi-stage magnetophoresis to remove magnetically-labeled white blood cells. The monolithic CTC-iChip enables debulking of blood samples at 15-20 million cells per second while yielding an output of highly purified CTCs. We quantified the size and EpCAM expression of over 2,500 CTCs from 38 patient samples obtained from breast, prostate, lung cancers, and melanoma. The results show significant heterogeneity between and within single patients. Unbiased, rapid, and automated isolation of CTCs using monolithic CTC-iChip will enable the detailed measurement of their physicochemical and biological properties and their role in metastasis.

  16. LePIX: First results from a novel monolithic pixel sensor

    International Nuclear Information System (INIS)

    Mattiazzo, S.; Battaglia, M.; Bisello, D.; Caselle, M.; Chalmet, P.; Demaria, N.; Giubilato, P.; Ikemoto, Y.; Kloukinas, K.; Mansuy, C.; Marchioro, A.; Mugnier, H.; Pantano, D.; Potenza, A.; Rivetti, A.; Rousset, J.; Silvestrin, L.; Snoeys, W.; Wyss, J.

    2013-01-01

    We present a monolithic pixel sensor developed in the framework of the LePIX project aimed at tracking/triggering tasks where high granularity, low power consumption, material budget, radiation hardness and production costs are a concern. The detector is built in a 90 nm CMOS process on a substrate of moderate resistivity. This maintains the advantages usually offered by Monolithic Active Pixel Sensors (MAPS), like a low input capacitance, having a single piece detector and using a standard CMOS production line, but offers charge collection by drift from a depleted region and therefore an excellent signal to noise ratio and a radiation tolerance superior to conventional undepleted MAPS. Measurement results obtained with the first prototypes from laser, radioactive source and beam test experiments are described. The excellent signal-to-noise performance is demonstrated by the capability of the device to separate the peaks in the spectrum of a 55 Fe source. We will also highlight the interaction between pixel cell design and architecture which points toward a very precise direction in the development of such depleted monolithic pixel devices for high energy physics

  17. An analysis of reliability and validity of the papilla index score of implant-supported single crowns of maxillary central incisors

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2012-01-01

    Objectives: To test the reliability and validity of the papilla index scores of the implant-supported single crowns (ISSCs) of maxillary central incisors. Materials and Methods: Twenty-five patients with 25 ISSCs were included. Two prosthodontists evaluated the papilla index score (PIS) of three ...... inter-observer agreement. The PIS score demonstrated significant correlation to the corresponding PP value (rs=.567, p=.000). Conclusions: The feasibility, reliability and validity of the PIS made the parameter useful for quality control of the pri-implant soft tissue of ISSCs.......Objectives: To test the reliability and validity of the papilla index scores of the implant-supported single crowns (ISSCs) of maxillary central incisors. Materials and Methods: Twenty-five patients with 25 ISSCs were included. Two prosthodontists evaluated the papilla index score (PIS) of three...

  18. Bypassing the central bottleneck after single-task practice in the psychological refractory period paradigm: evidence for task automatization and greedy resource recruitment.

    Science.gov (United States)

    Maquestiaux, François; Laguë-Beauvais, Maude; Ruthruff, Eric; Bherer, Louis

    2008-10-01

    In this research, the controversial issue of whether the central bottleneck can be bypassed through task automatization was investigated. To examine this issue, participants received six single-task practice sessions with an auditory-vocal task (low vs. high pitch). We then assessed dual-task performance using the analytically tractable psychological refractory period (PRP) paradigm, in which the highly practiced auditory-vocal task was presented as Task 2, along with an unpracticed visual-manual Task 1. The results provide evidence of bottleneck bypass for virtually all the participants (17 out of 20). Several converging tests suggest that the bottleneck reemerged, however, in a follow-up experiment with tasks presented in the opposite order (auditory-vocal Task 1 and visual-manual Task 2). One possible explanation is that tasks greedily recruit central resources when available, even though they can operate without central resources when unavailable.

  19. Microstructural characteristics of HIP-bonded monolithic nuclear fuels with a diffusion barrier

    Science.gov (United States)

    Jue, Jan-Fong; Keiser, Dennis D.; Breckenridge, Cynthia R.; Moore, Glenn A.; Meyer, Mitchell K.

    2014-05-01

    Due to the limitation of maximum uranium load achievable by dispersion fuel type, the Global Threat Reduction Initiative is developing an advanced monolithic fuel to convert US high-performance research reactors to low-enriched uranium. Hot-isostatic-press (HIP) bonding was the single process down-selected to bond monolithic U-Mo fuel meat to aluminum alloy cladding. A diffusion barrier was applied to the U-Mo fuel meat by roll-bonding process to prevent extensive interaction between fuel meat and aluminum-alloy cladding. Microstructural characterization was performed on fresh fuel plates fabricated at Idaho National Laboratory. Interfaces between the fuel meat, the cladding, and the diffusion barrier, as well as between the U-10Mo fuel meat and the Al-6061 cladding, were characterized by scanning electron microscopy. Preliminary results indicate that the interfaces contain many different phases while decomposition, second phases, and chemical banding were also observed in the fuel meat. The important attributes of the HIP-bonded monolithic fuel are: line. Some of these attributes might be critical to the irradiation performance of monolithic U-10Mo nuclear fuel. There are several issues or concerns that warrant more detailed study, such as precipitation along the cladding-to-cladding bond line, chemical banding, uncovered fuel-zone edge, and the interaction layer between the U-Mo fuel meat and zirconium. Future post-irradiation examination results will focus, among other things, on identifying in-reactor failure mechanisms and, eventually, directing further fresh fuel characterization efforts.

  20. Fast calibration of SPECT monolithic scintillation detectors using un-collimated sources

    Science.gov (United States)

    España, Samuel; Deprez, Karel; Van Holen, Roel; Vandenberghe, Stefaan

    2013-07-01

    Monolithic scintillation detectors for positron emission tomography and single-photon emission computed tomography (SPECT) imaging have many advantages over pixelated detectors. The use of monolithic crystals allows for reducing the scintillator cost per unit volume and increasing the sensitivity along with the energy and timing resolution of the detector. In addition, on thick detectors the depth-of-interaction can be determined without additional hardware. However, costly and complex calibration procedures have been proposed to achieve optimal detector performance for monolithic detectors. This hampers their use in commercial systems. There is thus, a need for simple calibration routines that can be performed on assembled systems. The main goal of this work is to develop a simplified calibration procedure based on acquired training data. In comparison with other methods that use training data acquired with beam sources attached to robotic stages, the proposed method uses a static un-collimated activity source with simple geometry acquiring in a reasonable time. Once the data are acquired, the calibration of the detector is accomplished in three steps: energy calibration based on the k-means clustering method, self-organization based on the self-organizing maps algorithm, and distortion correction based on the Monge-Kantorovich grid adaptation. The proposed calibration method was validated for 2D positioning using a SPECT detector. Similar results were obtained by comparison with an existing calibration method (maximum likelihood estimation). In conclusion, we proposed a novel calibration method for monolithic scintillation detectors that greatly simplifies their use with optimal performance in SPECT systems.

  1. Post-Polymerization Modifications of Polymeric Monolithic Columns: A Review

    Directory of Open Access Journals (Sweden)

    Sinéad Currivan

    2014-02-01

    Full Text Available The vast cache of methods used in polymeric monolithic column modification is presented herein, with specific attention to post-polymerization modification reactions. The modification of polymeric monolithic columns is defined and can include the modification of pre-existing surface groups, the addition of polymeric chains or indeed the addition of structures such as nano-particles and nano-structures. The use of these modifications can result in the specific patterning of monoliths, useful in microfluidic device design or in the investigation of modification optimization.

  2. Monolithic fuel injector and related manufacturing method

    Science.gov (United States)

    Ziminsky, Willy Steve [Greenville, SC; Johnson, Thomas Edward [Greenville, SC; Lacy, Benjamin [Greenville, SC; York, William David [Greenville, SC; Stevenson, Christian Xavier [Greenville, SC

    2012-05-22

    A monolithic fuel injection head for a fuel nozzle includes a substantially hollow vesicle body formed with an upstream end face, a downstream end face and a peripheral wall extending therebetween, an internal baffle plate extending radially outwardly from a downstream end of the bore, terminating short of the peripheral wall, thereby defining upstream and downstream fuel plenums in the vesicle body, in fluid communication by way of a radial gap between the baffle plate and the peripheral wall. A plurality of integral pre-mix tubes extend axially through the upstream and downstream fuel plenums in the vesicle body and through the baffle plate, with at least one fuel injection hole extending between each of the pre-mix tubes and the upstream fuel plenum, thereby enabling fuel in the upstream plenum to be injected into the plurality of pre-mix tubes. The fuel injection head is formed by direct metal laser sintering.

  3. Determining leach rates of monolithic waste forms

    International Nuclear Information System (INIS)

    Gilliam, T.M.; Dole, L.R.

    1986-01-01

    The ANS 16.1 Leach Procedure provides a conservative means of predicting long-term release from monolithic waste forms, offering a simple and relatively quick means of determining effective solid diffusion coefficients. As presented here, these coefficients can be used in a simple model to predict maximum release rates or be used in more complex site-specific models to predict actual site performance. For waste forms that pass the structural integrity test, this model also allows the prediction of EP-Tox leachate concentrations from these coefficients. Thus, the results of the ANS 16.1 Leach Procedure provide a powerful tool that can be used to predict the waste concentration limits in order to comply with the EP-Toxicity criteria for characteristically nonhazardous waste. 12 refs., 3 figs

  4. Present status of the MONOLITH project

    International Nuclear Information System (INIS)

    Petrukhin, A.A.

    2001-01-01

    MONOLITH is a proposed massive (34 kt) magnetized tracking calorimeter at the Gran Sasso laboratory in Italy, optimized for the detection of atmospheric muon neutrinos. The main goal is to establish (or reject) the neutrino oscillation hypothesis through an explicit observation of the full first oscillation swing. The Δm 2 sensitivity range for this measurement comfortably covers the complete Super-Kamiokande allowed region. Other measurements include studies of matter effects, the NC up/down ratio, ν bar / ν ratio, the study of cosmic ray muons in the multi-TeV range, and auxiliary measurements from the CERN to Gran Sasso neutrino beam. Depending on approval, data taking with the part of the detector could start towards the end of 2004

  5. Transparent monolithic metal ion containing nanophase aerogels

    Energy Technology Data Exchange (ETDEWEB)

    Risen, W. M., Jr.; Hu, X.; Ji, S.; Littrell, K.

    1999-12-01

    The formation of monolithic and transparent transition metal containing aerogels has been achieved through cooperative interactions of high molecular weight functionalized carbohydrates and silica precursors, which strongly influence the kinetics of gelation. After initial gelation, subsequent modification of the ligating character of the system, coordination of the group VIII metal ions, and supercritical extraction afford the aerogels. The structures at the nanophase level have been probed by photon and electron transmission and neutron scattering techniques to help elucidate the basis for structural integrity together with the small entity sizes that permit transparency in the visible range. They also help with understanding the chemical reactivities of the metal-containing sites in these very high surface area materials. These results are discussed in connection with new reaction studies.

  6. Skin antisepsis with 0.05% sodium hypochlorite before central venous catheter insertion in neonates: A 2-year single-center experience.

    Science.gov (United States)

    Ciccia, Matilde; Chakrokh, Roksana; Molinazzi, Dario; Zanni, Angela; Farruggia, Patrizia; Sandri, Fabrizio

    2018-02-01

    The study reports a 2-year single-center experience of the practice of skin antisepsis using a 0.05% sodium hypochlorite solution before central venous catheter placement in neonates. Eligible subjects included any hospitalized neonate who needed a central line for at least 48 hours. Infants were excluded if they had a generalized or localized skin disorder. An ad hoc Excel (Microsoft Corp, Redmond, WA) file was used to record the data from each patient. The catheter sites were monitored daily for the presence of contact dermatitis. Central line-associated bloodstream infection was diagnosed according to Centers for Disease Control and Prevention definition. One hundred five infants underwent central venous catheter placement and were enrolled. A total of 198 central lines were inserted. The median gestational age was 31 weeks (range, 23-41 weeks) and median birth weight was 1,420 g (range, 500-5,170 g). There were no signs of 0.05% sodium hypochlorite-related skin toxicity in any infant. Of 198 catheters (1,652 catheter-days) prospectively studied, 9 were associated with bloodstream infections (5.4 per 1,000 catheter-days). During the observation period, no local adverse effects were observed suggesting that 0.05% sodium hypochlorite may be a safe choice in this context. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  7. Pilot tests of a PET detector using the TOF-PET ASIC based on monolithic crystals and SiPMs

    International Nuclear Information System (INIS)

    Aguilar, A.; González-Montoro, A.; González, A.J.; Hernández, L.; Monzó, J.M.; Benlloch, J.M.; Bugalho, R.; Ferramacho, L.

    2016-01-01

    In this work we show pilot tests of PET detector blocks using the TOF-PET ASIC, coupled to SiPM detector arrays and different crystal configurations. We have characterized the main ASIC features running calibration processes to compensate the time dispersion among the different ASIC/SiPM paths as well as for the time walk on the arrival of optical photons. The aim of this work is to use of LYSO monolithic crystals and explore their photon Depth of Interaction (DOI) capabilities, keeping good energy and spatial resolutions. First tests have been carried out with crystal arrays. Here we made it possible to reach a coincidence resolving times (CRT) of 370 ps FWHM, with energy resolutions better than 20% and resolving well 2 mm sized crystal elements. When using monolithic crystals, a single-pixel LYSO reference crystal helped to explore the CRT performance. We studied different strategies to provide the best timestamp determination in the monolithic scintillator. Times around 1 ns FWHM have been achieved in these pilot studies. In terms of spatial and energy resolution, values of about 3 mm and better than 30% were found, respectively. We have also demonstrated the capability of this system (monolithic and ASIC) to return accurate DOI information.

  8. Monolithically integrated quantum dot optical modulator with semiconductor optical amplifier for thousand and original band optical communication

    Science.gov (United States)

    Yamamoto, Naokatsu; Akahane, Kouichi; Umezawa, Toshimasa; Matsumoto, Atsushi; Kawanishi, Tetsuya

    2016-04-01

    A monolithically integrated quantum dot (QD) optical gain modulator (OGM) with a QD semiconductor optical amplifier (SOA) was successfully developed with T-band (1.0 µm waveband) and O-band (1.3 µm waveband) QD optical gain materials for Gbps-order, high-speed optical data generation. The insertion loss due to coupling between the device and the optical fiber was effectively compensated for by the SOA section. It was also confirmed that the monolithic QD-OGM/SOA device enabled >4.8 Gbps optical data generation with a clear eye opening in the T-band. Furthermore, we successfully demonstrated error-free 4.8 Gbps optical data transmissions in each of the six wavelength channels over a 10-km-long photonic crystal fiber using the monolithic QD-OGM/SOA device in multiple O-band wavelength channels, which were generated by the single QD gain chip. These results suggest that the monolithic QD-OGM/SOA device will be advantageous in ultra-broadband optical frequency systems that utilize the T+O-band for short- and medium-range optical communications.

  9. Profiling of drug binding proteins by monolithic affinity chromatography in combination with liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Zhang, Xuepei; Wang, Tongdan; Zhang, Hanzhi; Han, Bing; Wang, Lishun; Kang, Jingwu

    2014-09-12

    A new approach for proteome-wide profiling drug binding proteins by using monolithic capillary affinity chromatography in combination with HPLC-MS/MS is reported. Two immunosuppresive drugs, namely FK506 and cyclosporin A, were utilized as the experimental models for proof-of-concept. The monolithic capillary affinity columns were prepared through a single-step copolymerization of the drug derivatives with glycidyl methacrylate and ethylene dimethacrylate. The capillary chromatography with the affinity monolithic column facilitates the purification of the drug binding proteins from the cell lysate. By combining the capillary affinity column purification and the shot-gun proteomic analysis, totally 33 FK506- and 32 CsA-binding proteins including all the literature reported target proteins of these two drugs were identified. Among them, two proteins, namely voltage-dependent anion-selective channel protein 1 and serine/threonine-protein phosphatase PGAM5 were verified by using the recombinant proteins. The result supports that the monolithic capillary affinity chromatography is likely to become a valuable tool for profiling of binding proteins of small molecular drugs as well as bioactive compounds. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Monolithic Rare Earth Doped PTR Glass Laser, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The main goal of the project is to demonstrate the feasibility of a monolithic solid state laser on the basis of PTR glass co-doped with luminescent rare earth ions....

  11. Packaged, cascadable wideband monolithic feedback amplifiers for radar systems applications

    OpenAIRE

    Alleva, V.; Calori, M.; Cetronio, A.; Lanzieri, C.; Proietti, C.; Rapisarda, S.

    1990-01-01

    Design criteria and fabrication of a packaged, monolithic, cascadable, feedback amplifier are presented. The good performances in term of bandwidth, gain, flatness, reproducibility and reliability makes this component highly suitable for many radar applications.

  12. Reliability Analysis and Optimal Design of Monolithic Vertical Wall Breakwaters

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Burcharth, Hans F.; Christiani, E.

    1994-01-01

    Reliability analysis and reliability-based design of monolithic vertical wall breakwaters are considered. Probabilistic models of the most important failure modes, sliding failure, failure of the foundation and overturning failure are described . Relevant design variables are identified and relia...

  13. Plant oil-based shape memory polymer using acrylic monolith

    Directory of Open Access Journals (Sweden)

    T. Tsujimoto

    2015-09-01

    Full Text Available This article deals with the synthesis of a plant oil-based material using acrylic monolith. An acrylic monolith bearing oxirane groups was prepared via simple technique that involved the dissolution of poly(glycidyl methacrylate-comethyl methacrylate (PGMA in ethanolic – aqueous solution by heating and subsequent cooling. The PGMA monolith had topologically porous structure, which was attributed to the phase separation of the polymer solution. The PGMA monolith was impregnated by epoxidized soybean oil (ESO containing thermally-latent catalyst, and the subsequent curing produced a crosslinked material with relatively good transparency. The Young’s modulus and the tensile strength of polyESO/PGMA increased compared with the ESO homopolymer. The strain at break of polyESO/PGMA was larger than that of the ESO homopolymer and crosslinked PGMA. Furthermore, polyESO/PGMA exhibited good shape memory-recovery behavior.

  14. Application of monolithic chromatographic supports in virus research.

    Science.gov (United States)

    Krajacic, Mladen; Ravnikar, Maja; Štrancar, Aleš; Gutiérrez-Aguirre, Ion

    2017-11-01

    Key properties of monolithic chromatographic supports, make them suitable for separation and/or concentration of large biomolecules, especially virus particles and viral genomes. One by one, the studies that have been completed so far, contributed to the knowledge that monolith chromatography has hardly any limitation to be applied in virus research. Viruses of different sizes, possessing icosahedral structure and symmetrical morphology, as well as rod-shaped or filamentous viruses with helical structure, even enveloped ones, all of them could be successfully managed by means of monolith chromatography. Same is true for viral genomes, primarily when being distinct from other nucleic acid forms present in a host cell. This review is exclusively focused on viruses. It describes the application of monolith chromatography to different problematics within the virus research field. The reviewed achievements offer new possibilities and trigger new aspects in virology. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Effect of accelerated aging on translucency of monolithic zirconia

    Directory of Open Access Journals (Sweden)

    O. Abdelbary

    2016-12-01

    Conclusion: Thickness of zirconia has significant effect on translucency. Aging has significant effect on thinner sections of zirconia. More research is required on zirconia towards making the material more translucent for its potential use as esthetic monolithic restoration.

  16. Microchip-based monolithic column for high performance liquid chromatography

    Data.gov (United States)

    National Aeronautics and Space Administration — We have developed microchip based monolithic columns that can be used for liquid chromatography of small organic molecules, as well as, macromolecules such as...

  17. Monolithic Perovskite Silicon Tandem Solar Cells with Advanced Optics

    Energy Technology Data Exchange (ETDEWEB)

    Goldschmidt, Jan C.; Bett, Alexander J.; Bivour, Martin; Blasi, Benedikt; Eisenlohr, Johannes; Kohlstadt, Markus; Lee, Seunghun; Mastroianni, Simone; Mundt, Laura; Mundus, Markus; Ndione, Paul; Reichel, Christian; Schubert, Martin; Schulze, Patricia S.; Tucher, Nico; Veit, Clemens; Veurman, Welmoed; Wienands, Karl; Winkler, Kristina; Wurfel, Uli; Glunz, Stefan W.; Hermle, Martin

    2016-11-14

    For high efficiency monolithic perovskite silicon tandem solar cells, we develop low-temperature processes for the perovskite top cell, rear-side light trapping, optimized perovskite growth, transparent contacts and adapted characterization methods.

  18. A symmetric positive definite formulation for monolithic fluid structure interaction

    KAUST Repository

    Robinson-Mosher, Avi

    2011-02-01

    In this paper we consider a strongly coupled (monolithic) fluid structure interaction framework for incompressible flow, as opposed to a loosely coupled (partitioned) method. This requires solving a single linear system that combines the unknown velocities of the structure with the unknown pressures of the fluid. In our previous work, we were able to obtain a symmetric formulation of this coupled system; however, it was also indefinite, making it more difficult to solve. In fact in practice there have been cases where we have been unable to invert the system. In this paper we take a novel approach that consists of factoring the damping matrix of deformable structures and show that this can be used to obtain a symmetric positive definite system, at least to the extent that the uncoupled systems were symmetric positive definite. We use a traditional MAC grid discretization of the fluid and a fully Lagrangian discretization of the structures for the sake of exposition, noting that our procedure can be generalized to other scenarios. For the special case of rigid bodies, where there are no internal damping forces, we exactly recover the system of Batty et al. (2007) [4]. © 2010 Elsevier Inc.

  19. A monolithic charge multiplexer with 0.5% accuracy

    International Nuclear Information System (INIS)

    Lewis, J.; McPherson, G.M.; Morrissey, M.C.; Thompson, J.C.; Tucker, A.W.

    1990-01-01

    This paper describes a 16 channel monolithic charge multiplexer providing a close tolerance, low cost, low power solution to the problem of handling the signals from detectors with large numbers of channels. Outputs may be wire-orred to increase the degree of multiplexing. A system designed with this chip and with suitable close tolerance processing downstream will have a gain match of ±0.5% and a front end chip cost of approximately $1 per channel. The chip is fabricated in CMOS technology and the test of a 1500 channel system has demonstrated the feasibility of CMOS in this context. The chip produces a prompt sum of the charges from the 16 signal sources and integrates and stores the individual charges for later serial readout. A single network provides amplifier bias and releases area to facilitate optimum noise performance and signal handling. Amplifier and bias network design together with p-well screens to isolate storage capacitors from the substrate provide the power line rejection essential in systems generating a trigger from large numbers of channels. (orig.)

  20. Randomized controlled trial comparing different single doses of intravenous paracetamol for placement of peripherally inserted central catheters in preterm infants

    NARCIS (Netherlands)

    D.W.E. Roofthooft (Daniella); S.H. Simons (Sinno); R.A. Lingen (Richard); D. Tibboel (Dick); J.N. van den Anker (John); I.K.M. Reiss (Irwin); M. van Dijk (Monique)

    2017-01-01

    markdownabstract__Background:__ The availability of a safe and effective pharmacological therapy to reduce procedural pain in preterm infants is limited. The effective analgesic single dose of intravenous paracetamol in preterm infants is unknown. Comparative studies on efficacy of different

  1. Sol-Gel Synthesis of Non-Silica Monolithic Materials

    Science.gov (United States)

    Gaweł, Bartłomiej; Gaweł, Kamila; Øye, Gisle

    2010-01-01

    Monolithic materials have become very popular because of various applications, especially within chromatography and catalysis. Large surface areas and multimodal porosities are great advantages for these applications. New sol-gel preparation methods utilizing phase separation or nanocasting have opened the possibility for preparing materials of other oxides than silica. In this review, we present different synthesis methods for inorganic, non-silica monolithic materials. Some examples of application of the materials are also included.

  2. Evaluation of translucency of monolithic zirconia and framework zirconia materials

    OpenAIRE

    Tuncel, ?lkin; Turp, I??l; ???mez, Asl?han

    2016-01-01

    PURPOSE The opacity of zirconia is an esthetic disadvantage that hinders achieving natural and shade-matched restorations. The aim of this study was to evaluate the translucency of non-colored and colored framework zirconia and monolithic zirconia. MATERIALS AND METHODS The three groups tested were: non-colored framework zirconia, colored framework zirconia with the A3 shade according to Vita Classic Scale, and monolithic zirconia (n=5). The specimens were fabricated in the dimensions of 15?1...

  3. Extended Leach Testing of Simulated LAW Cast Stone Monoliths

    Energy Technology Data Exchange (ETDEWEB)

    Serne, R. Jeffrey [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westsik, Joseph H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jung, H. B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Guohui [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-07-09

    This report describes the results from long-term laboratory leach tests performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate the release of key constituents from monoliths of Cast Stone prepared with four simulated low-activity waste (LAW) liquid waste streams. Specific objectives of the Cast Stone long-term leach tests described in this report focused on four activities: 1. Extending the leaching times for selected ongoing EPA-1315 tests on monoliths made with LAW simulants beyond the conventional 63-day time period up to 609 days reported herein (with some tests continuing that will be documented later) in an effort to evaluate long-term leaching properties of Cast Stone to support future performance assessment activities. 2. Starting new EPA-1315 leach tests on archived Cast Stone monoliths made with four LAW simulants using two leachants (deionized water [DIW] and simulated Hanford Integrated Disposal Facility (IDF) Site vadose zone pore water [VZP]). 3. Evaluating the impacts of varying the iodide loading (starting iodide concentrations) in one LAW simulant (7.8 M Na Hanford Tank Waste Operations Simulator (HTWOS) Average) by manufacturing new Cast Stone monoliths and repeating the EPA-1315 leach tests using DIW and the VZP leachants. 4. Evaluating the impacts of using a non-pertechnetate form of Tc that is present in some Hanford tanks. In this activity one LAW simulant (7.8 M Na HTWOS Average) was spiked with a Tc(I)-tricarbonyl gluconate species and then solidified into Cast Stone monoliths. Cured monoliths were leached using the EPA-1315 leach protocol with DIW and VZP. The leach results for the Tc-Gluconate Cast Stone monoliths were compared to Cast Stone monoliths pertechnetate.

  4. Performance characteristics between monolithic and microservice-based systems

    OpenAIRE

    Flygare, Robin; Holmqvist, Anthon

    2017-01-01

    A new promising technology to face the problem of scalability and availability is the microservice architecture. The problem with this architecture is that there is no significant study that clearly proves the performance differences compared to the monolithic architecture. Our thesis aims to provide a more conclusive answer of how the microservice architecture differs performance wise compared to the monolithic architecture. In this study, we conducted several experiments on a self-developed...

  5. 100% reflectivity from a monolithic dielectric microstructured surface

    OpenAIRE

    Brückner, F.; Clausnitzer, T.; Burmeister, O.; Friedrich, D.; Kley, E.; Danzmann, K.; Tünnermann, A.; Schnabel, R.

    2008-01-01

    Here, we propose a new mirror architecture which is solely based upon a monolithic dielectric micro-structured surface. Hence, the mirror device, which consists of a possibly mono-crystalline bulk material, can in principle simultaneously provide perfect reflectivity and lowest mechanical loss. By specifically structuring the monolithic surface, resulting in T-shaped ridges of a subwavelength grating, a resonant behavior of light coupling can be realized, leading to theoretically 100% reflect...

  6. Sol-Gel Synthesis of Non-Silica Monolithic Materials

    Directory of Open Access Journals (Sweden)

    Bartłomiej Gaweł

    2010-04-01

    Full Text Available Monolithic materials have become very popular because of various applications, especially within chromatography and catalysis. Large surface areas and multimodal porosities are great advantages for these applications. New sol-gel preparation methods utilizing phase separation or nanocasting have opened the possibility for preparing materials of other oxides than silica. In this review, we present different synthesis methods for inorganic, non-silica monolithic materials. Some examples of application of the materials are also included.

  7. Sol-Gel Synthesis of Non-Silica Monolithic Materials

    OpenAIRE

    Gawe?, Bart?omiej; Gawe?, Kamila; ?ye, Gisle

    2010-01-01

    Monolithic materials have become very popular because of various applications, especially within chromatography and catalysis. Large surface areas and multimodal porosities are great advantages for these applications. New sol-gel preparation methods utilizing phase separation or nanocasting have opened the possibility for preparing materials of other oxides than silica. In this review, we present different synthesis methods for inorganic, non-silica monolithic materials. Some examples of appl...

  8. Classifying Pediatric Central Nervous System Tumors through near Optimal Feature Selection and Mutual Information: A Single Center Cohort

    Directory of Open Access Journals (Sweden)

    Mohammad Faranoush

    2013-10-01

    Full Text Available Background: Labeling, gathering mutual information, clustering and classificationof central nervous system tumors may assist in predicting not only distinct diagnosesbased on tumor-specific features but also prognosis. This study evaluates the epidemi-ological features of central nervous system tumors in children who referred to Mahak’sPediatric Cancer Treatment and Research Center in Tehran, Iran.Methods: This cohort (convenience sample study comprised 198 children (≤15years old with central nervous system tumors who referred to Mahak's PediatricCancer Treatment and Research Center from 2007 to 2010. In addition to the descriptiveanalyses on epidemiological features and mutual information, we used the LeastSquares Support Vector Machines method in MATLAB software to propose apreliminary predictive model of pediatric central nervous system tumor feature-labelanalysis. Results:Of patients, there were 63.1% males and 36.9% females. Patients' mean±SDage was 6.11±3.65 years. Tumor location was as follows: supra-tentorial (30.3%, infra-tentorial (67.7% and 2% (spinal. The most frequent tumors registered were: high-gradeglioma (supra-tentorial in 36 (59.99% patients and medulloblastoma (infra-tentorialin 65 (48.51% patients. The most prevalent clinical findings included vomiting,headache and impaired vision. Gender, age, ethnicity, tumor stage and the presence ofmetastasis were the features predictive of supra-tentorial tumor histology.Conclusion: Our data agreed with previous reports on the epidemiology of centralnervous system tumors. Our feature-label analysis has shown how presenting features maypartially predict diagnosis. Timely diagnosis and management of central nervous systemtumors can lead to decreased disease burden and improved survival. This may be furtherfacilitated through development of partitioning, risk prediction and prognostic models.

  9. Clinical profile and etiologies of children with central diabetes insipidus: a single-center experience from Turkey.

    Science.gov (United States)

    Catli, Gonul; Abaci, Ayhan; Demir, Korcan; Ulusoy, Emel; Altincik, Ayca; Buyukgebiz, Atilla; Bober, Ece

    2012-01-01

    The aim of this study is to evaluate the clinical, anthropometric, hormonal, and radiological characteristics of children with central diabetes insipidus (DI). Case records of 34 children (22 boys and 12 girls) with documented central DI referred to the Pediatric Endocrinology and Adolescent Clinic of Dokuz Eylul University Faculty of Medicine were reviewed. The mean age at diagnosis was 6.4 +/- 5.6 years (range, 0.08-16 years). All patients underwent anterior pituitary function assessment and magnetic resonance imaging of pituitary at diagnosis. The median duration of follow-up was 7.9 +/- 4.5 years. The etiology of central DI was organic in 22 (64.7%) patients, trauma in 2 (5.9%) patients, and idiopathic in 10 (29.4%) patients. Organic causes consisted of craniopharyngioma in 7 patients, Langerhans cell histiocytosis in 4 patients, germinoma in 4 patients, holoprosencephaly in 3 patients, astrocytoma in 1 patient, cavernous hemangioma in 1 patient, Rathke's cleft cyst in 1 patient, and autoimmune polyendocrinopathy in 1 patient. Anterior pituitary hormone deficiencies were documented in 18 (53%) patients. Organic central DI group had a greater prevalence of anterior pituitary hormone deficiency when compared with the idiopathic group (66% and 10%, respectively; p = 0.007). The final height of patients with organic etiology were significantly lower than the idiopathic group (155 and 178, cm respectively; p = 0.021). Etiological diagnosis is possible in a significant proportion (70.6%) of children with central DI. Findings of this study suggest that accompanying anterior pituitary hormone deficiencies and short stature may be considered as indicators of organic etiology.

  10. Nano-Doped Monolithic Materials for Molecular Separation

    Directory of Open Access Journals (Sweden)

    Caleb Acquah

    2017-01-01

    Full Text Available Monoliths are continuous adsorbents that can easily be synthesised to possess tuneable meso-/macropores, convective fluid transport, and a plethora of chemistries for ligand immobilisation. They are grouped into three main classes: organic, inorganic, and hybrid, based on their chemical composition. These classes may also be differentiated by their unique morphological and physicochemical properties which are significantly relevant to their specific separation applications. The potential applications of monoliths for molecular separation have created the need to enhance their characteristic properties including mechanical strength, electrical conductivity, and chemical and thermal stability. An effective approach towards monolith enhancement has been the doping and/or hybridization with miniaturized molecular species of desirable functionalities and characteristics. Nanoparticles are usually preferred as dopants due to their high solid phase dispersion features which are associated with improved intermolecular adsorptive interactions. Examples of such nanomaterials include, but are not limited to, carbon-based, silica-based, gold-based, and alumina nanoparticles. The incorporation of these nanoparticles into monoliths via in situ polymerisation and/or post-modification enhances surface adsorption for activation and ligand immobilisation. Herein, insights into the performance enhancement of monoliths as chromatographic supports by nanoparticles doping are presented. In addition, the potential and characteristics of less common nanoparticle materials such as hydroxyapatite, ceria, hafnia, and germania are discussed. The advantages and challenges of nanoparticle doping of monoliths are also discussed.

  11. The Effect of a Single Session of Whole-Body Vibration Training in Recreationally Active Men on the Excitability of the Central and Peripheral Nervous System

    Directory of Open Access Journals (Sweden)

    Chmielewska Daria

    2014-07-01

    Full Text Available Vibration training has become a popular method used in professional sports and recreation. In this study, we examined the effect of whole-body vibration training on the central nervous system and muscle excitability in a group of 28 active men. Subjects were assigned randomly to one of two experimental groups with different variables of vibrations. The chronaximetry method was used to evaluate the effect of a single session of whole-body vibration training on the excitability of the rectus femoris and brachioradialis muscles. The examination of the fusing and flickering frequencies of the light stimulus was performed. An increase in the excitability of the quadriceps femoris muscle due to low intensity vibrations (20 Hz frequency, 2 mm amplitude was noted, and a return to the initial values was observed 30 min after the application of vibration. High intensity vibrations (60 Hz frequency, 4 mm amplitude caused elongations of the chronaxy time; however, these differences were not statistically significant. Neither a low intensity vibration amplitude of 2 mm (frequency of 20 Hz nor a high intensity vibration amplitude of 4 mm (frequency of 60 Hz caused a change in the excitability of the central nervous system, as revealed by the average frequency of the fusing and flickering of the light stimulus. A single session of high intensity whole-body vibration did not significantly decrease the excitability of the peripheral nervous system while the central nervous system did not seem to be affected.

  12. Monoliths: A Review of the Basics, Preparation Methods and Their Relevance to Oxidation

    Directory of Open Access Journals (Sweden)

    Sandeeran Govender

    2017-02-01

    Full Text Available Considerable research has been conducted on monolithic catalysts for various applications. Strategies toward coating monoliths are of equal interest and importance. In this paper, the preparation of monoliths and monolithic catalysts have been summarized. More specifically, a brief explanation for the manufacturing of ceramic and metallic monoliths has been provided. Also, different methods for coating γ-alumina, as a secondary support, are included. Techniques used to deposit metal-based species, zeolites and carbon onto monoliths are discussed. Furthermore, monoliths extruded with metal oxides, zeolites and carbon are described. The main foci are on the reasoning and understanding behind the preparation of monolithic catalysts. Ideas and concerns are also contributed to encourage better approaches when designing these catalysts. More importantly, the relevance of monolithic structures to reactions, such as the selective oxidation of alkanes, catalytic combustion for power generation and the preferential oxidation of carbon monoxide, has been described.

  13. Frontend Receiver Electronics for High Frequency Monolithic CMUT-on-CMOS Imaging Arrays

    OpenAIRE

    Gurun, Gokce; Hasler, Paul; Degertekin, F. Levent

    2011-01-01

    This paper describes the design of CMOS receiver electronics for monolithic integration with capacitive micromachined ultrasonic transducer (CMUT) arrays for high-frequency intravascular ultrasound imaging. A custom 8-inch wafer is fabricated in a 0.35 μm two-poly, four-metal CMOS process and then CMUT arrays are built on top of the application specific integrated circuits (ASICs) on the wafer. We discuss advantages of the single-chip CMUT-on-CMOS approach in terms of receive sensitivity and ...

  14. You Can't Unscramble an Egg: Population Genetic Structure of Oncorhynchus mykiss in the California Central Valley Inferred from Combined Microsatellite and Single Nucleotide Polymorphism Data

    Directory of Open Access Journals (Sweden)

    Devon E. Pearse

    2015-12-01

    Full Text Available doi: http://dx.doi.org/10.15447/sfews.2015v13iss4art3Steelhead/rainbow trout (Oncorhynchus mykiss are found in all of the major tributaries of the Sacramento and San Joaquin rivers, which flow through California’s Central Valley and enter the ocean through San Francisco Bay and the Golden Gate. This river system is heavily affected by water development, agriculture, and invasive species, and salmon and trout hatchery propagation has been occurring for over 100 years. We collected genotype data for 18 highly variable microsatellite loci and 95 single nucleotide polymorphisms (SNPs from more than 1,900 fish from Central Valley drainages to analyze genetic diversity, population structure, differentiation between populations above and below dams, and the relationship of Central Valley O. mykiss populations to coastal California steelhead. In addition, we evaluate introgression by both hatchery rainbow trout strains, which have primarily native Central Valley ancestry, and imported coastal steelhead stocks. In contrast to patterns typical of coastal steelhead, Central Valley O. mykiss above and below dams within the same tributary were not found to be each others’ closest relatives, and we found no relationship between genetic and geographic distance among below-barrier populations. While introgression by hatchery rainbow trout strains does not appear to be widespread among above-barrier populations, steelhead in the American River and some neighboring tributaries have been introgressed by coastal steelhead. Together, these results demonstrate that the ancestral population genetic structure that existed among Central Valley tributaries has been significantly altered in contemporary populations. Future conservation, restoration, and mitigation efforts should take this into account when working to meet recovery planning goals.

  15. Polymethacrylate Monolithic and Hybrid Particle-Monolithic Columns for Reversed-Phase and Hydrophilic Interaction Capillary Liquid Chromatography

    Czech Academy of Sciences Publication Activity Database

    Jandera, P.; Urban, J.; Škeříková, V.; Langmeier, P.; Kubíčková, R.; Planeta, Josef

    2010-01-01

    Roč. 1217, č. 1 (2010), s. 22-33 ISSN 0021-9673 R&D Projects: GA ČR GA203/08/1536 Institutional research plan: CEZ:AV0Z40310501 Keywords : particle-monolithic columns * hybrid columns * polymethacrylate monoliths * capillary HPLC * HILIC * proteins * phenolic acids Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.194, year: 2010

  16. Uso de motores monofásicos acoplados mecanicamente em série, em irrigação por pivô central Utilization of mechanically coupled single phase motors in series in central pivot irrigation system

    Directory of Open Access Journals (Sweden)

    Delly Oliveira Filho

    2005-03-01

    Full Text Available A utilização de sistemas de irrigação por pivô central requer elevada potência elétrica, o que, em geral, implica em alto investimento inicial. No Brasil, a maioria das fazendas é eletrificada no sistema monofásico, devido ao fato de sua implantação requerer cerca de 40% do investimento inicial exigido pelo sistema trifásico. Salienta-se que a maior potência disponível no mercado de motores monofásicos no Brasil é de 9,2 kW (12,5 cv. Para suprir demanda de potência acima desta com sistema monofásico, propõe-se acoplar os motores monofásicos mecanicamente em série. Este trabalho teve como objetivo estimar o rendimento de um sistema de acoplamento e sua viabilidade técnico-econômica, comparado-o com outras formas de fornecimento de energia, diesel e sistema elétrico trifásico.The utilization of central pivot irrigation system requires in most cases high electric power which imply in high initial investment. Most of the Brazilian farms are electrified in the single phase electrical system, due to the fact that their implementation requires only about 40% of the initial investment as compared to three phase system. In Brazilian market the highest available power of single phase motors is 9.2 kW (12.5 hp. To supply power demand above this limit with single phase system one could couple mechanically the single phase motors in series. The objective of this work was to estimate the efficiency of such coupling system and to evaluate the economic and technical feasibility compared with other forms of energy supply such as diesel and three phase electrical system.

  17. Frequency stability and offset locking of a laser-diode-pumped Nd:YAG monolithic nonplanar ring oscillator

    Science.gov (United States)

    Kane, Thomas J.; Nilsson, Alan C.; Byer, Robert L.

    1987-01-01

    The frequency stability of laser-diode-pumped, monolithic Nd:YAG solid-state unidirectional nonplanar ring oscillators was studied by heterodyne measurements. CW single-axial- and transverse-mode power of 25 mW at 1064 nm was obtained at a slope efficiency of 19 percent. Two independent oscillators were offset-locked at 17 MHz with frequency fluctuations of less than + or - 40 kHz for periods of 8 min.

  18. Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer

    Science.gov (United States)

    Siegel, Peter; Schlecht, Erich; Mehdi, Imran; Gill, John; Velebir, James; Tsang, Raymond; Dengler, Robert; Lin, Robert

    2010-01-01

    This device is a biasable, submillimeter-wave, balanced mixer fabricated using JPL s monolithic membrane process a simplified version of planar membrane technology. The primary target application is instrumentation used for analysis of atmospheric constituents, pressure, temperature, winds, and other physical and chemical properties of the atmospheres of planets and comets. Other applications include high-sensitivity gas detection and analysis. This innovation uses a balanced configuration of two diodes allowing the radio frequency (RF) signal and local oscillator (LO) inputs to be separated. This removes the need for external diplexers that are inherently narrowband, bulky, and require mechanical tuning to change frequency. Additionally, this mixer uses DC bias-ability to improve its performance and versatility. In order to solve problems relating to circuit size, the GaAs membrane process was created. As much of the circuitry as possible is fabricated on-chip, making the circuit monolithic. The remainder of the circuitry is precision-machined into a waveguide block that holds the GaAs circuit. The most critical alignments are performed using micron-scale semiconductor technology, enabling wide bandwidth and high operating frequencies. The balanced mixer gets superior performance with less than 2 mW of LO power. This can be provided by a simple two-stage multiplier chain following an amplifier at around 90 GHz. Further, the diodes are arranged so that they can be biased. Biasing pushes the diodes closer to their switching voltage, so that less LO power is required to switch the diodes on and off. In the photo, the diodes are at the right end of the circuit. The LO comes from the waveguide at the right into a reduced-height section containing the diodes. Because the diodes are in series to the LO signal, they are both turned on and off simultaneously once per LO cycle. Conversely, the RF signal is picked up from the RF waveguide by the probe at the left, and flows

  19. Monotherapy with methotrexate for primary central nervous lymphoma has single agent activity in the absence of radiotherapy: a single institution cohort.

    Science.gov (United States)

    Cobert, Julien; Hochberg, Ephraim; Woldenberg, Nina; Hochberg, Fred

    2010-07-01

    We have retrospectively reviewed toxicities and response of a cohort of primary central nervous system lymphoma (PCNSL) patients treated with high dose parenteral methotrexate (MTX) monotherapy without whole brain radiation. From The Massachusetts General Hospital (MGH) Cancer Registry, active since 1946, we selected all immunocompetent patients with histologic and/or radiographic PCNSL diagnosed between 1980 and 2007. We identified the recipients of MTX with leucovorin rescue as sole therapy. No patient received radiation therapy (XRT). We analyzed this cohort for toxicity, response and patterns of recurrence. The cohort of 121 patients received on average 11 cycles of intravenous MTX at a median dose of 8 g/m(2). Median interval between cycles was 10 days. After 3 months of therapy, the overall response rate was 85% (58% CR, 27% PR). The overall survival (OS) for the cohort was 7 years and progression-free survival (PFS) was 3.14 years. A trend toward a higher PFS was seen in patients who continued to receive MTX (3.48 years) every three months as compared to patients who ceased MTX after one year (2.86 years). Of 68 patients who achieved initial CR, there were 40 recurrences. Twenty-six of the 40 were re-induced with MTX as above; Sixty-nine percent again achieved CR. Eighty-one treatment-related toxicities occurred in 1316 MTX cycles. These toxicities included MRI white matter changes (N = 8) and lead to MTX cessation in 16 patients. High-dose MTX monotherapy of PCNSL is well-tolerated and provides PFS of >3 years and OS >7 years.

  20. A new application of monolithic supports: the separation of viruses from one another.

    Science.gov (United States)

    Ruščić, J; Gutiérrez-Aguirre, I; Žnidarič, M Tušek; Kolundžija, S; Slana, A; Barut, M; Ravnikar, M; Krajačić, M

    2015-04-03

    The emergence of next-generation "deep" sequencing has enabled the study of virus populations with much higher resolutions. This new tool increases the possibility of observing mixed infections caused by combinations of plant viruses, which are likely to occur more frequently than previously thought. The biological impact of co-infecting viruses on their host has yet to be determined and fully understood, and the first step towards reaching this goal is the separation and purification of individual species. Ion-exchange monolith chromatography has been used successfully for the purification and concentration of different viruses, and number of them have been separated from plant homogenate or bacterial and eukaryotic lysate. Thus, the question remained as to whether different virus species present in a single sample could be separated. In this study, anion-exchange chromatography using monolithic supports was optimized for fast and efficient partial purification of three model plant viruses: Turnip yellow mosaic virus, Tomato bushy stunt virus, and Tobacco mosaic virus. The virus species, as well as two virus strains, were separated from each other in a single chromatographic experiment from an artificially mixed sample. Based on A260/280 ratios, we were able to attribute specific peaks to a certain viral morphology/structure (icosahedral or rod-shaped). This first separation of individual viruses from an artificially prepared laboratory mixture should encourage new applications of monolithic chromatographic supports in the separation of plant, bacterial, or animal viruses from all kinds of mixed samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Solid oxide fuel cell with monolithic core

    Science.gov (United States)

    McPheeters, C.C.; Mrazek, F.C.

    1988-08-02

    A solid oxide fuel cell in which fuel and oxidant gases undergo an electrochemical reaction to produce an electrical output includes a monolithic core comprised of a corrugated conductive sheet disposed between upper and lower generally flat sheets. The corrugated sheet includes a plurality of spaced, parallel, elongated slots which form a series of closed, linear, first upper and second lower gas flow channels with the upper and lower sheets within which a fuel gas and an oxidant gas respectively flow. Facing ends of the fuel cell are generally V-shaped and provide for fuel and oxidant gas inlet and outlet flow, respectively, and include inlet and outlet gas flow channels which are continuous with the aforementioned upper fuel gas and lower oxidant gas flow channels. The upper and lower flat sheets and the intermediate corrugated sheet are preferably comprised of ceramic materials and are securely coupled together such as by assembly in the green state and sintering together during firing at high temperatures. A potential difference across the fuel cell, or across a stacked array of similar fuel cells, is generated when an oxidant gas such as air and a fuel such as hydrogen gas is directed through the fuel cell at high temperatures, e.g., between 700 C and 1,100 C. 8 figs.

  2. Properties of glass-bonded zeolite monoliths

    International Nuclear Information System (INIS)

    Lewis, M.A.; Fischer, D.F.; Murphy, C.D.

    1994-01-01

    It has been shown that mineral waste forms can be used to immobilize waste salt generated during the pyrochemical processing of spent fuel from the Integral Fast Reactor (IFR). Solid, leach resistant monoliths were formed by hot-pressing mixtures of salt-occluded zeolite A powders and glass frit at 990 K and 28 MPa. Additional samples have now been fabricated and tested. Normalized release rates for all elements, including iodide and chloride, were less than 1 g/m 2 d in 28-day tests in deionized water and in brine at 363 K (90 degrees C). Preliminary results indicate that these rates fall with time with both leachants and that the zeolite phase in the glass-bonded zeolite does not function as an ion exchanger. Some material properties were measured. The Poisson ratio and Young's modulus were slightly smaller in glass-bonded zeolite than in borosilicate glass. Density depended on zeolite fraction. The glass-bonded zeolite represents a promising mineral waste form for IFR salt

  3. Characterisation of methacrylate monoliths for bacteriophage purification.

    Science.gov (United States)

    Smrekar, Franc; Ciringer, Mateja; Strancar, Aleš; Podgornik, Aleš

    2011-04-29

    Binding of three different bacteriophages (phages), namely T7, lambda and M13 on methacrylate monoliths was investigated. Phage M13 exhibited the highest dynamic binding capacity of 4.5×10(13) pfu/mL while T7 and lambda showed capacity of 1×10(13) pfu/mL, all corresponding to values of around 1mg/mL. Interestingly, capacity for lambda phage was increased 5-fold by increasing NaCl concentration in a loaded sample from 0 to 0.2M while there was a constant capacity decrease for T7 and M13 phages. Under optimal conditions, recovery for all three phages approached 100%. Measurement of a pressure drop increase during loading enabled estimation of adsorbed phage layer thickness. At a maximal capacity it was calculated to be around 50 nm for T7 phage and 60 nm for lambda phage matching closely capside size thus indicating monolayer adsorption while 80 nm layer thickness was estimated for M13 phage showing its orientation along the pore. Copyright © 2010 Elsevier B.V. All rights reserved.

  4. Single-Cell Transcriptional Analysis Reveals Novel Neuronal Phenotypes and Interaction Networks Involved in the Central Circadian Clock.

    Science.gov (United States)

    Park, James; Zhu, Haisun; O'Sullivan, Sean; Ogunnaike, Babatunde A; Weaver, David R; Schwaber, James S; Vadigepalli, Rajanikanth

    2016-01-01

    Single-cell heterogeneity confounds efforts to understand how a population of cells organizes into cellular networks that underlie tissue-level function. This complexity is prominent in the mammalian suprachiasmatic nucleus (SCN). Here, individual neurons exhibit a remarkable amount of asynchronous behavior and transcriptional heterogeneity. However, SCN neurons are able to generate precisely coordinated synaptic and molecular outputs that synchronize the body to a common circadian cycle by organizing into cellular networks. To understand this emergent cellular network property, it is important to reconcile single-neuron heterogeneity with network organization. In light of recent studies suggesting that transcriptionally heterogeneous cells organize into distinct cellular phenotypes, we characterized the transcriptional, spatial, and functional organization of 352 SCN neurons from mice experiencing phase-shifts in their circadian cycle. Using the community structure detection method and multivariate analytical techniques, we identified previously undescribed neuronal phenotypes that are likely to participate in regulatory networks with known SCN cell types. Based on the newly discovered neuronal phenotypes, we developed a data-driven neuronal network structure in which multiple cell types interact through known synaptic and paracrine signaling mechanisms. These results provide a basis from which to interpret the functional variability of SCN neurons and describe methodologies toward understanding how a population of heterogeneous single cells organizes into cellular networks that underlie tissue-level function.

  5. Single-cell Transcriptional Analysis Reveals Novel Neuronal Phenotypes and Interaction Networks involved In the Central Circadian Clock

    Directory of Open Access Journals (Sweden)

    James Park

    2016-10-01

    Full Text Available Single-cell heterogeneity confounds efforts to understand how a population of cells organizes into cellular networks that underlie tissue-level function. This complexity is prominent in the mammalian suprachiasmatic nucleus (SCN. Here, individual neurons exhibit a remarkable amount of asynchronous behavior and transcriptional heterogeneity. However, SCN neurons are able to generate precisely coordinated synaptic and molecular outputs that synchronize the body to a common circadian cycle by organizing into cellular networks. To understand this emergent cellular network property, it is important to reconcile single-neuron heterogeneity with network organization. In light of recent studies suggesting that transcriptionally heterogeneous cells organize into distinct cellular phenotypes, we characterized the transcriptional, spatial, and functional organization of 352 SCN neurons from mice experiencing phase-shifts in their circadian cycle. Using the community structure detection method and multivariate analytical techniques, we identified previously undescribed neuronal phenotypes that are likely to participate in regulatory networks with known SCN cell types. Based on the newly discovered neuronal phenotypes, we developed a data-driven neuronal network structure in which multiple cell types interact through known synaptic and paracrine signaling mechanisms. These results provide a basis from which to interpret the functional variability of SCN neurons and describe methodologies towards understanding how a population of heterogeneous single cells organizes into cellular networks that underlie tissue-level function.

  6. The effects of a single intravenous injection of novel activin A/BMP-2 (AB204) on toxicity and the respiratory and central nervous systems.

    Science.gov (United States)

    Yoon, Byung-Hak; Lee, Jae Hyup; Na, Kyuheum; Ahn, Chihoon; Cho, Jongho; Ahn, Hyun Chan; Choi, Jungyoun; Oh, Hyosun; Kim, Byong Moon; Choe, Senyon

    2016-01-01

    The purpose of this study was to determine the effects of a single intravenous injection of a novel osteoinductive material, activin A/BMP-2 (AB204), to rodents on toxicity and their respiratory functions and central nervous system (CNS). A single intravenous injection of AB204 was given to Sprague-Dawley (SD) rats in doses of 0, 0.625, 2.5 and 10 mg/kg to observe the mortality rate, the general symptoms for 14 days. The experimental groups were also given 0.2, 0.4 and 0.8 mg/kg of AB204, respectively, and the respiration rate, the tidal volume and the minute volume were measured for 240 min. The experimental groups of imprinting control region (ICR) mice were given a single intravenous injection of 0.2, 0.4 and 0.8 mg/kg of AB204, respectively. Their body temperature was taken and general behaviors were observed to evaluate the effect of AB204 on the CNS for 240 min. The study on toxicity of a single intravenous injection found no death or abnormal symptoms, abnormal findings from autopsy, or abnormal body weight gain or loss in all the experimental groups. No abnormal variation associated with the test substance was observed in the respiration rate, the tidal volume, the minute volume, body temperature or the general behaviors. On the basis of these results, the approximate lethal dose of AB204 for a single intravenous injection exceeds 10 mg/kg for SD rats and a single intravenous injection of ≤0.8 mg/kg AB204 has no effect on their respiratory system for SD rat and no effect on their CNS for ICR mice.

  7. The Magnitude of Peripheral Muscle Fatigue Induced by High and Low Intensity Single-Joint Exercise Does Not Lead to Central Motor Output Reductions in Resistance Trained Men.

    Directory of Open Access Journals (Sweden)

    Paul W M Marshall

    Full Text Available To examine quadriceps muscle fatigue and central motor output during fatiguing single joint exercise at 40% and 80% maximal torque output in resistance trained men.Ten resistance trained men performed fatiguing isometric knee extensor exercise at 40% and 80% of maximal torque output. Maximal torque, rate of torque development, and measures of central motor output and peripheral muscle fatigue were recorded at two matched volumes of exercise, and after a final contraction performed to exhaustion. Central motor output was quantified from changes in voluntary activation, normalized surface electromyograms (EMG, and V-waves. Quadriceps muscle fatigue was assessed from changes in the size and shape of the resting potentiated twitch (Q.(pot.tw. Central motor output during the exercise protocols was estimated from EMG and interpolated twitches applied during the task (VA(sub.Greater reductions in maximal torque and rate of torque development were observed during the 40% protocol (p<0.05. Maximal central motor output did not change for either protocol. For the 40% protocol reductions from pre-exercise in rate and amplitude variables calculated from the Q.(pot.tw between 66.2 to 70.8% (p<0.001 exceeded those observed during the 80% protocol (p<0.01. V-waves only declined during the 80% protocol between 56.8 ± 35.8% to 53.6 ± 37.4% (p<0.05. At the end of the final 80% contraction VA(sub had increased from 91.2 ± 6.2% to 94.9 ± 4.7% (p = 0.005, but a greater increase was observed during the 40% contraction where VA(sub had increased from 67.1 ± 6.1% to 88.9 ± 9.6% (p<0.001.Maximal central motor output in resistance trained men is well preserved despite varying levels of peripheral muscle fatigue. Upregulated central motor output during the 40% contraction protocol appeared to elicit greater peripheral fatigue. V-waves declines during the 80% protocol suggest intensity dependent modulation of the Ia afferent pathway.

  8. Fracture resistance of monolithic zirconia molar crowns with reduced thickness.

    Science.gov (United States)

    Nakamura, Keisuke; Harada, Akio; Inagaki, Ryoichi; Kanno, Taro; Niwano, Yoshimi; Milleding, Percy; Örtengren, Ulf

    2015-01-01

    The purpose of the present study was to analyze the relationship between fracture load of monolithic zirconia crowns and axial/occlusal thickness and to evaluate the fracture resistance of monolithic zirconia crowns with reduced thickness in comparison with that of monolithic lithium disilicate crowns with regular thickness. Monolithic zirconia crowns (Lava Plus Zirconia, 3M/ESPE) with specified axial/occlusal thicknesses and lithium disilicate crowns (IPS e.max press, Ivoclar/Vivadent) with regular thickness were fabricated using a dental CAD/CAM system and a press technique, respectively. The crowns cemented onto dies were loaded until fracture. Based on measurements of the crown thickness made by micro-CT and the fracture load, multiple regression analysis was performed. It was revealed that the occlusal thickness significantly affected the fracture load (p zirconia crowns, the fracture load of the zirconia crowns with the occlusal thickness of 0.5 mm (5558 ± 522 N) was significantly higher than that of lithium disilicate crowns with an occlusal thickness of 1.5 mm (3147 ± 409 N). Within the limitations of the present study, it is suggested that monolithic zirconia crown with chamfer width of 0.5 mm and occlusal thickness of 0.5 mm can be used in the molar region in terms of fracture resistance.

  9. Surfactant-Bound Monolithic Columns for Capillary Electrochromatography

    Science.gov (United States)

    Gu, Congying; He, Jun; Jia, Jinping; Fang, Nenghu; Shamsi, Shahab A.

    2010-01-01

    A novel anionic surfactant bound monolithic stationary phase based on 11-acrylaminoundecanoic acid (AAUA) is designed for capillary electrochromatography (CEC). The monolith possessing bonded undecanoyl groups (hydrophobic sites) and carboxyl groups (weak cationic ion-exchange sites) was evaluated as a mixed-mode stationary phase in CEC for the separation of neutral and polar solutes. Using a multivariate D-optimal design the composition of the polymerization mixture was modeled and optimized with five alkylbenzenes (ABs) and seven alkyl phenyl ketones (APKs) as test solutes. The D-optimal design indicates a strong dependence of electrochromatographic parameters on the concentration of AAUA monomer and porogen (water) in the polymerization mixture. A difference of 6%, 8% and 13% RSD between the predicted and the experimental values in terms of efficiency, resolution, and retention time, respectively, indeed confirmed that the proposed approach is practical. The physical (i.e., morphology, porosity and permeability) and chromatographic properties of the monolithic columns were thoroughly investigated. With the optimized monolithic column, high efficiency separation of N-methylcarbamates (NMCs) pesticides and positional isomers was successfully achieved. It appears that this type of mixed-mode monolith (containing both chargeable and hydrophobic sites) may have a great potential as a new generation of CEC stationary phase. PMID:19885887

  10. Edge chipping and flexural resistance of monolithic ceramics☆

    Science.gov (United States)

    Zhang, Yu; Lee, James J.-W.; Srikanth, Ramanathan; Lawn, Brian R.

    2014-01-01

    Objective Test the hypothesis that monolithic ceramics can be developed with combined esthetics and superior fracture resistance to circumvent processing and performance drawbacks of traditional all-ceramic crowns and fixed-dental-prostheses consisting of a hard and strong core with an esthetic porcelain veneer. Specifically, to demonstrate that monolithic prostheses can be produced with a much reduced susceptibility to fracture. Methods Protocols were applied for quantifying resistance to chipping as well as resistance to flexural failure in two classes of dental ceramic, microstructurally-modified zirconias and lithium disilicate glass–ceramics. A sharp indenter was used to induce chips near the edges of flat-layer specimens, and the results compared with predictions from a critical load equation. The critical loads required to produce cementation surface failure in monolithic specimens bonded to dentin were computed from established flexural strength relations and the predictions validated with experimental data. Results Monolithic zirconias have superior chipping and flexural fracture resistance relative to their veneered counterparts. While they have superior esthetics, glass–ceramics exhibit lower strength but higher chip fracture resistance relative to porcelain-veneered zirconias. Significance The study suggests a promising future for new and improved monolithic ceramic restorations, with combined durability and acceptable esthetics. PMID:24139756

  11. Monolithic Chip-Integrated Absorption Spectrometer from 3-5 microns, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A monolithically integrated indium phosphide (InP) to silicon-on-sapphire (SoS) platform is being proposed for a monolithic portable or handheld spectrometer between...

  12. Monolithic PDMS passband filters for fluorescence detection.

    Science.gov (United States)

    Llobera, Andreu; Demming, Stefanie; Joensson, Haakan N; Vila-Planas, J; Andersson-Svahn, Helene; Büttgenbach, Stephanus

    2010-08-07

    We present the fabrication and characteristics of monolithically integrated ink dyed poly(dimethylsiloxane) (PDMS) filters for optical sensing in disposable lab-on-a-chip. This represents a migration of auxillary functions onto the disposable chip with the goal of producing truly portable systems. Filters made from commercially available ink (Pelikan) directly mixed into PDMS oligomer without the use of any additional solvents were patterned with standard soft lithography technologies. Furthermore, a fabrication process based on capillary forces is presented allowing PDMS coloration of arbitrary shapes. Different filters of varying thickness fabricated using red, green and blue ink in four different concentrations were characterized. The optimal performance was found with filter thicknesses of 250 microm and ink to PDMS ratios of 0.1 (mL ink : mL PDMS oligomer) resulting in a transmittance ranging from -15.1 dB to -12.3 dB in the stopband and from -4.0 dB to -2.5 dB in the passband. Additionally, we demonstrate the robustness of this approach as the ink dyed PDMS filters do not exhibit temporal ageing due to diffusion or autofluorescence. We also show that such filters can easily be integrated in fluorescence systems, with stopbands efficient enough to allow fluorescence measurements under non-optimal conditions (broadband excitation, 180 degrees configuration). Integrated ink dyed PDMS filters add robust optical functionalities to disposable microdevices at a low cost and will enable the use of these devices for a wide range of fluorescence and absorbance based biological and chemical analysis.

  13. Diode-side-pumped monolithic Nd:YAG slab laser

    Science.gov (United States)

    Šulc, Jan; Jelínek, Michal; Kubeček, Václav; Jelínková, Helena; Nejezchleb, Karel; Škoda, Václav

    2017-05-01

    Compact, high-efficient, side-pumped monolithic Nd:YAG slab laser is presented. Designed active crystal shape ensures four internal reflections of generated laser radiation forming a ring resonator with high gain. A horizontal projection of the active medium form was a isosceles trapezoid with 18.6 mm long base, and 5 mm height. The angels between long base and legs are 87 deg. The thickness of the slab was 4 mm. Both base-sides and one leg-side was high reflective for lasing radiation. Second leg-side was partially reflective for lasing radiation and serves as an output coupler. The longer base-side was highly transparent for pumping radiation. The opposite base-side was highly reflecting for pump. To increase the pump absorption efficiency Nd-doping concentration was 1.4 % Nd/Y. As a pump source, single-bar quasi-cw fast-axis collimated laser diode JOLD-180-QPFN (Jenoptik) with peak power 180 W at 808 nm and output beam 10 0.9 mm without any further optics was used for slab side-pumping. The pumping pulses with repetition rate 5 Hz were 250 μs long (maximum pump energy 39 mJ). The Nd:YAG laser was operated at 1.06 µm. Two external mirrors (one totally reflecting, second with reflectivity 80 % at 1.06 μm) were used to form the oscillator. The laser was tested in the free-running regime. The maximum laser output energy reached was 5.9 mJ which corresponds to optical-to-optical efficiency of 15 %. The laser slope efficiency in respect to laser diode output was 20 %. The divergence of multimode output beam was 7 × 2.5mrad.

  14. AlGaN/GaN-on-Si monolithic power-switching device with integrated gate current booster

    Science.gov (United States)

    Han, Sang-Woo; Jo, Min-Gi; Kim, Hyungtak; Cho, Chun-Hyung; Cha, Ho-Young

    2017-08-01

    This study investigates the effects of a monolithic gate current booster integrated with an AlGaN/GaN-on-Si power-switching device. The integrated gate current booster was implemented by a single-stage inverter topology consisting of a recessed normally-off AlGaN/GaN MOS-HFET and a mesa resistor. The monolithically integrated gate current booster in a switching FET eliminated the parasitic elements caused by external interconnection and enabled fast switching operation. The gate charging and discharging currents were boosted by the integrated inverter, which significantly reduced both rise and fall times: the rise time was reduced from 626 to 41.26 ns, while the fall time was reduced from 554 to 42.19 ns by the single-stage inverter. When the packaged monolithic power chip was tested under 1 MHz hard-switching operation with VDD = 200 V, the switching loss was found to have been drastically reduced, from 5.27 to 0.55 W.

  15. Exploring sub-daily to seasonal variations in methane exchange in a single-crop rice paddy in central Japan

    Science.gov (United States)

    Iwata, Hiroki; Mano, Masayoshi; Ono, Keisuke; Tokida, Takeshi; Kawazoe, Takahiro; Kosugi, Yoshiko; Sakabe, Ayaka; Takahashi, Kenshi; Miyata, Akira

    2018-04-01

    Season-long methane (CH4) exchange was observed in a rice paddy field in central Japan (Kanto Region) using the eddy covariance technique to clarify the variations in environmental controls on CH4 exchange in different stages of cultivation. Before heading of rice plant, the CH4 emission depended on wind speed and soil temperature. The soil temperature dependence can be due to an increase in CH4 production, higher molecular diffusion, and higher conductance within rice plant at higher soil temperature. An occurrence of ebullitive emission was also suggested from the wind speed dependence. After heading was completed, relative humidity and water temperature influenced CH4 emission. The amplitude of the diurnal variation in emission increased from 0.03 μmolm-2s-1 in the late pre-heading stage to 0.13 μmolm-2s-1 in the post-heading stage. Induced convective throughflow within the rice aerenchyma after the change in plant structure was attributable to this variation in environmental controls after the heading. After drainage, CH4 emission was confined to short periods after strong rain events. The water level controlled the timing of emission, most likely by influencing the diffusion efficiency from the anoxic soil to the atmosphere and CH4 oxidation in the surface oxic zone. The variation in the dominant transport pathway needs to be accounted for in terrestrial ecosystem models to accurately predict CH4 emission from rice paddies.

  16. Bee venom acupuncture point injection for central post stroke pain: a preliminary single-blind randomized controlled trial.

    Science.gov (United States)

    Cho, Seung-Yeon; Park, Joo-Young; Jung, Woo-Sang; Moon, Sang-Kwan; Park, Jung-Mi; Ko, Chang-Nam; Park, Seong-Uk

    2013-06-01

    We investigated apipuncture, or acupuncture point injection with diluted bee venom, as a promising new treatment for central post stroke pain (CPSP). Bee venom, diluted to 0.005% in normal saline, was administered to the treatment group, and normal saline given to control group as twice-weekly injections for three weeks. The points were LI15, GB21, LI11, GB31, ST36 and GB39 of the affected side and the amount of injection was 0.05 ml at each point. Eight patients in each group were included in the analysis. After three weeks there were significant decreases in visual analogue pain scores compared with baseline in both groups and the treatment group improved more significantly than the control group (p = 0.009). Apipuncture significantly improved CPSP in this pilot trial. Further studies of its mechanisms and a larger and long-term follow-up trial will be needed to determine more definitely the efficacy of apipuncture and to elucidate duration of improvement. Copyright © 2013 Elsevier Ltd. All rights reserved.

  17. Single-neuron diversity generated by Protocadherin-β cluster in mouse central and peripheral nervous systems

    Directory of Open Access Journals (Sweden)

    Keizo eHirano

    2012-08-01

    Full Text Available The generation of complex neural circuits depends on the correct wiring of neurons with diverse individual characteristics. To understand the complexity of the nervous system, the molecular mechanisms for specifying the identity and diversity of individual neurons must be elucidated. The clustered protocadherins (Pcdh in mammals consist of approximately 50 Pcdh genes (Pcdh-α, Pcdh-β, and Pcdh-γ that encode cadherin-family cell surface adhesion proteins. Individual neurons express a random combination of Pcdh-α and Pcdh-γ, whereas the expression patterns for the Pcdh-β genes, 22 one-exon genes in mouse, are not fully understood. Here we show that the Pcdh-β genes are expressed in a 3’-polyadenylated form in mouse brain. In situ hybridization using a pan-Pcdh-β probe against a conserved Pcdh-β sequence showed widespread labeling in the brain, with prominent signals in the olfactory bulb, hippocampus, and cerebellum. In situ hybridization with specific probes for individual Pcdh-β genes showed their expression to be scattered in Purkinje cells from P10 to P150. The scattered expression patterns were confirmed by performing a newly developed single-cell 3’-RACE analysis of Purkinje cells, which clearly demonstrated that the Pcdh-β genes are expressed monoallelically and combinatorially in individual Purkinje cells. Scattered expression patterns of individual Pcdh-β genes were also observed in pyramidal neurons in the hippocampus and cerebral cortex, neurons in the trigeminal and dorsal root ganglion, GABAergic interneurons, and cholinergic neurons. Our results extend previous observations of diversity at the single-neuron level generated by Pcdh expression and suggest that the Pcdh-β cluster genes contribute to specifying the identity and diversity of individual neurons.

  18. Cerec anterior crowns: restorative options with monolithic ceramic materials.

    Science.gov (United States)

    Reich, Sven; Fiedlar, Kurt

    2013-01-01

    The aim of this article is to discuss the different types of monolithic ceramic crowns that can be placed on anterior teeth with existing shoulder preparations. Anterior crowns were indicated for the teeth 12 to 22 in the present case. The patient, a 65-year-old male, had received all-ceramic crowns 20 years earlier, which had started to develop cracks and palatal fractures over the last few years. The patient's teeth were prepared and four sets of crowns were fabricated using different monolithic ceramic materials: IPS e.max CAD, Cerec Blocs C In, VITABLOCS Real Life, and ENAMIC. Both shade characterization and crystallization firing were performed on the monolithic lithium disilicate glass ceramic crowns. The silicate ceramic crowns received glaze firing alone. The crowns made of hybrid ceramic (ENAMIC) were treated with a polymer sealant.

  19. Monolithic optoelectronic integrated broadband optical receiver with graphene photodetectors

    Directory of Open Access Journals (Sweden)

    Cheng Chuantong

    2017-07-01

    Full Text Available Optical receivers with potentially high operation bandwidth and low cost have received considerable interest due to rapidly growing data traffic and potential Tb/s optical interconnect requirements. Experimental realization of 65 GHz optical signal detection and 262 GHz intrinsic operation speed reveals the significance role of graphene photodetectors (PDs in optical interconnect domains. In this work, a novel complementary metal oxide semiconductor post-backend process has been developed for integrating graphene PDs onto silicon integrated circuit chips. A prototype monolithic optoelectronic integrated optical receiver has been successfully demonstrated for the first time. Moreover, this is a firstly reported broadband optical receiver benefiting from natural broadband light absorption features of graphene material. This work is a perfect exhibition of the concept of monolithic optoelectronic integration and will pave way to monolithically integrated graphene optoelectronic devices with silicon ICs for three-dimensional optoelectronic integrated circuit chips.

  20. Monolithic optoelectronic integrated broadband optical receiver with graphene photodetectors

    Science.gov (United States)

    Cheng, Chuantong; Huang, Beiju; Mao, Xurui; Zhang, Zanyun; Zhang, Zan; Geng, Zhaoxin; Xue, Ping; Chen, Hongda

    2017-07-01

    Optical receivers with potentially high operation bandwidth and low cost have received considerable interest due to rapidly growing data traffic and potential Tb/s optical interconnect requirements. Experimental realization of 65 GHz optical signal detection and 262 GHz intrinsic operation speed reveals the significance role of graphene photodetectors (PDs) in optical interconnect domains. In this work, a novel complementary metal oxide semiconductor post-backend process has been developed for integrating graphene PDs onto silicon integrated circuit chips. A prototype monolithic optoelectronic integrated optical receiver has been successfully demonstrated for the first time. Moreover, this is a firstly reported broadband optical receiver benefiting from natural broadband light absorption features of graphene material. This work is a perfect exhibition of the concept of monolithic optoelectronic integration and will pave way to monolithically integrated graphene optoelectronic devices with silicon ICs for three-dimensional optoelectronic integrated circuit chips.

  1. Effect of the number of coloring liquid applications on the optical properties of monolithic zirconia.

    Science.gov (United States)

    Kim, Hee-Kyung; Kim, Sung-Hun

    2014-09-01

    This study was aimed to investigate the effect of the number of coloring liquid applications on the optical properties of monolithic zirconia. Eighteen monolithic zirconia specimens (27.6 mm×27.6 mm×2.0 mm) were fabricated and divided into 6 groups (n=3). Each group was designated by the number of A2-coloring liquid applications (Group I to Group V) and Group O as a control. Color and spectral distribution of the specimens were measured with a double-beam spectrophotometer. CIE L*, a* and b* relative to the standard illuminants D65 were measured in reflectance and transmittance modes. Color difference (ΔEab*), translucency parameter (TP) and opalescence parameter (OP) were calculated. All measurements were performed on five different areas of each specimen. All data were analyzed by ANOVA and multiple comparison Scheffé test, Pearson correlations and linear regression analysis (α=0.05). With the increase of the number of coloring liquid applications, CIE L* (R2=0.878) and OP values (R2=0.701) were decreased, but CIE b* (R2=0.938) was increased. However, TP values were not significantly changed. The color differences among groups ranged from 1.3 to 15.7 ΔEab* units. Strong correlation was found between OP and Δb* (R2=0.982, Papplications with a single shade affects the lightness, yellow chromaticity and opalescence of monolithic zirconia, although its translucency cannot be controlled by the coloring procedure. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  2. Bioadsorption of proteins on large mesocage-shaped mesoporous alumina monoliths.

    Science.gov (United States)

    El-Safty, Sherif A; Shenashen, M A; Khairy, M

    2013-03-01

    With the remarkable progress in the field of gene technology, proteins have gained an important function in the field of disease diagnosis and treatment. Protein bioadsorption has drawn increasing attention partly because of the promising advances for diagnostic assays, sensors, separations, and gene technology. Mesocage alumina has a cage-type structure with high surface area and pore volume, exhibiting superior capabilities for protein adsorption. In this study, we report the size-selective adsorption/removal of virtual proteins having different shapes, sizes, functions, and properties, including insulin, HopPmaL domain, lysozyme, galectin-3, β-lactoglobulin, α-1-antitrypsin, α-amylase, and myosin in aqueous water using mesocage alumina. The mesoporous alumina monoliths have unique morphology and physical properties and enhanced protein adsorption characteristics in terms of sample loading capacity and quantity, thereby ensuring a higher concentration of proteins, interior pore diffusivity, and encapsulation in a short period. Thermodynamic analysis shows that protein adsorption on mesocage alumina monoliths is favorable and spontaneous. Theoretical models have been studied to investigate the major driving forces to achieve the most optimal performance of protein adsorption. The development of ultra- or micrometer-scale morphology composed of mesocage-shaped mesoporous monoliths or alumina network clusters can be effectively used to encapsulate the macromolecules into the interior cage cavities, which can greatly assist in other potentials for biomedical applications. Furthermore, the adsorption of a single protein from mixtures based on size- and shape-selective separation can open up new ways to produce micro-objects that suit a given protein encapsulation design. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Preparation of poly(γ-glutamic acid)/hydroxyapatite monolith via biomineralization for bone tissue engineering.

    Science.gov (United States)

    Park, Sung-Bin; Hasegawa, Urara; van der Vlies, André J; Sung, Moon-Hee; Uyama, Hiroshi

    2014-01-01

    A hybrid monolith of poly(γ-glutamic acid) and hydroxyapatite (PGA/HAp monolith) was prepared via biomineralization and used as a macroporous cell scaffold in bone tissue engineering. The PGA monolith having a bimodal pore size distribution was used as a substrate to induce biomineralization. The PGA/HAp monolith was obtained by immersing the PGA monolith in simulated body fluid. Pretreatment with CaCl2 enhanced the apatite-forming ability of the PGA monolith. Murine osteoblastic MC3T3-E1 cells efficiently attached and proliferated on the PGA/HAp monolith. MTT assay showed that both the PGA and PGA/HAp monolith did not have apparent cytotoxicity. Moreover, the PGA and PGA/HAp monoliths adsorbed bone morphogenetic protein-2 (BMP-2) by electrostatic interaction which was slowly released in the medium during cell culture. The PGA/HAp monolith enhanced BMP-2 induced alkaline phosphatase activity compared to the PGA monolith and a polystyrene culture plate. Thus, these PGA/HAp monoliths may have potential in bone tissue engineering.

  4. Single cell cultures of Drosophila neuroectodermal and mesectodermal central nervous system progenitors reveal different degrees of developmental autonomy

    Directory of Open Access Journals (Sweden)

    Technau Gerhard M

    2009-08-01

    Full Text Available Abstract Background The Drosophila embryonic central nervous system (CNS develops from two sets of progenitor cells, neuroblasts and ventral midline progenitors, which behave differently in many respects. Neuroblasts derive from the neurogenic region of the ectoderm and form the lateral parts of the CNS. Ventral midline precursors are formed by two rows of mesectodermal cells and build the CNS midline. There is plenty of evidence that individual identities are conferred to precursor cells by positional information in the ectoderm. It is unclear, however, how far the precursors can maintain their identities and developmental properties in the absence of normal external signals. Results To separate the respective contributions of autonomous properties versus extrinsic signals during their further development, we isolated individual midline precursors and neuroectodermal precursors at the pre-mitotic gastrula stage, traced their development in vitro, and analyzed the characteristics of their lineages in comparison with those described for the embryo. Although individually cultured mesectodermal cells exhibit basic characteristics of CNS midline progenitors, the clones produced by these progenitors differ from their in situ counterparts with regard to cell numbers, expression of molecular markers, and the separation of neuronal and glial fate. In contrast, clones derived from individually cultured precursors taken from specific dorsoventral zones of the neuroectoderm develop striking similarities to the lineages of neuroblasts that normally delaminate from these zones and develop in situ. Conclusion This in vitro analysis allows for the first time a comparison of the developmental capacities in situ and in vitro of individual neural precursors of defined spatial and temporal origin. The data reveal that cells isolated at the pre-mitotic and pre-delamination stage express characteristics of the progenitor type appropriate to their site of origin in

  5. Single cell cultures of Drosophila neuroectodermal and mesectodermal central nervous system progenitors reveal different degrees of developmental autonomy.

    Science.gov (United States)

    Lüer, Karin; Technau, Gerhard M

    2009-08-03

    The Drosophila embryonic central nervous system (CNS) develops from two sets of progenitor cells, neuroblasts and ventral midline progenitors, which behave differently in many respects. Neuroblasts derive from the neurogenic region of the ectoderm and form the lateral parts of the CNS. Ventral midline precursors are formed by two rows of mesectodermal cells and build the CNS midline. There is plenty of evidence that individual identities are conferred to precursor cells by positional information in the ectoderm. It is unclear, however, how far the precursors can maintain their identities and developmental properties in the absence of normal external signals. To separate the respective contributions of autonomous properties versus extrinsic signals during their further development, we isolated individual midline precursors and neuroectodermal precursors at the pre-mitotic gastrula stage, traced their development in vitro, and analyzed the characteristics of their lineages in comparison with those described for the embryo. Although individually cultured mesectodermal cells exhibit basic characteristics of CNS midline progenitors, the clones produced by these progenitors differ from their in situ counterparts with regard to cell numbers, expression of molecular markers, and the separation of neuronal and glial fate. In contrast, clones derived from individually cultured precursors taken from specific dorsoventral zones of the neuroectoderm develop striking similarities to the lineages of neuroblasts that normally delaminate from these zones and develop in situ. This in vitro analysis allows for the first time a comparison of the developmental capacities in situ and in vitro of individual neural precursors of defined spatial and temporal origin. The data reveal that cells isolated at the pre-mitotic and pre-delamination stage express characteristics of the progenitor type appropriate to their site of origin in the embryo. However, presumptive neuroblasts, once

  6. Fast methods for analysis of neurotransmitters from single cell and monitoring their releases in central nervous system by capillary electrophoresis, fluorescence microscopy and luminescence imaging

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Ziqiang [Iowa State Univ., Ames, IA (United States)

    1999-12-10

    Fast methods for separation and detection of important neurotransmitters and the releases in central nervous system (CNS) were developed. Enzyme based immunoassay combined with capillary electrophoresis was used to analyze the contents of amino acid neurotransmitters from single neuron cells. The release of amino acid neurotransmitters from neuron cultures was monitored by laser induced fluorescence imaging method. The release and signal transduction of adenosine triphosphate (ATP) in CNS was studied with sensitive luminescence imaging method. A new dual-enzyme on-column reaction method combined with capillary electrophoresis has been developed for determining the glutamate content in single cells. Detection was based on monitoring the laser-induced fluorescence of the reaction product NADH, and the measured fluorescence intensity was related to the concentration of glutamate in each cell. The detection limit of glutamate is down to 10-8 M level, which is 1 order of magnitude lower than the previously reported detection limit based on similar detection methods. The mass detection limit of a few attomoles is far superior to that of any other reports. Selectivity for glutamate is excellent over most of amino acids. The glutamate content in single human erythrocyte and baby rat brain neurons were determined with this method and results agreed well with literature values.

  7. Evaluation of fracture resistance of inlay-retained fixed partial dentures fabricated with different monolithic zirconia materials.

    Science.gov (United States)

    Gumus, Hilal Siriner; Polat, Nilufer Tulin; Yildirim, Guler

    2017-09-29

    Data are lacking on the fracture resistance of monolithic zirconia inlay-retained fixed partial dentures as a conservative treatment for a single missing tooth. The purpose of this in vitro study was to evaluate the fracture resistance of inlay-retained fixed partial dentures produced from 3 different monolithic zirconia materials and based on 2 preparation types and applications with and without thermocycling. A model with missing right and left mandibular first molars was used for different cavity preparations. A tube-shaped cavity and a box-shaped cavity were prepared. Seventy-two epoxy resin casts were prepared from an additional silicone impression. Twenty-four inlay-retained fixed partial dentures from each monolithic zirconia material (Prettau, Zirkonzahn; Katana, Noritake; and Copran, Whitepeaks) were fabricated for each preparation type and cemented to their epoxy model with dual-polymerizing adhesive resin cement; 50% of all specimens were thermocycled for 10000 cycles. The specimens were subjected to a fracture resistance test using a universal testing machine with a crosshead speed of 0.5 mm/min. Fracture surfaces were examined with scanning electron microscopy (SEM), and a specimen from each group was examined for structural changes with differential thermal analysis (DTA). No statistically significant differences in terms of fracture resistance were found among brands with both cavity designs and with and without thermal cycles (P>.05). However, SEM and DTA results showed some changes in monolithic zirconia structure after 1 year of aging. The brands and cavity preparation types for single posterior tooth loss generated similar fracture resistance. Copyright © 2017 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. Monolithic zirconia dental crowns. Internal fit, margin quality, fracture mode and load at fracture.

    Science.gov (United States)

    Schriwer, Christian; Skjold, Anneli; Gjerdet, Nils Roar; Øilo, Marit

    2017-09-01

    Dental all-ceramic restorations of zirconia, with and without an aesthetic veneering layer, have become a viable alternative to conventional metal-ceramic restorations. The aim of this study was to evaluate whether factors of the production methods or the material compositions affect load at fracture, fracture modes, internal fit or crown margins of monolithic zirconia crowns. Sixty crowns made from six different commercially available dental zirconias were produced to a model tooth with a shallow circumferential chamfer preparation. Internal fit was assessed by the replica method. The crown margin quality was assessed by light microscopy on an ordinal scale. The cemented crowns were loaded centrally in the occlusal fossa with a horizontal steel cylinder with a diameter of 13mm at 0.5mm/min until fracture. Fractographic analysis was performed on the fractured crowns. There were statistically significant differences among the groups regarding crown margins, internal fit and load at fracture (pFracture analyses revealed that all fractures started cervically and propagated to the occlusal surface similar to clinically observed fractures. There was statistically significant correlation between margin quality and load at fracture (Spearman's rank correlation, pfracture. The hard-machined Y-TZP zirconia crowns had the best margin quality and the highest load at fracture. Reduction of margin flaws will improve fracture strength of monolithic zirconia crowns and thereby increase clinical success. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Simulated performance of a small-animal PET scanner based on monolithic scintillation detectors

    International Nuclear Information System (INIS)

    Laan, D.J. van der; Maas, M.C.; Jong, H.W.A.M. de; Schaart, D.R.; Bruyndonckx, P.; Lemaitre, C.; Eijk, C.W.E. van

    2007-01-01

    The performance of a small-animal positron emission tomography (PET) scanner based on monolithic scintillation detectors read-out by avalanche photo-diode arrays has been investigated by simulation. By minimizing dead space, both within and between the modules, these detectors offer increased detection efficiency compared to pixellated detectors. The spatial resolution of the scanner was investigated in 2-D by simulating a point source at various radial distances from the center. To model the detector response, measured detector line-spread functions were used. An optimum value of approximately 1 mm FWHM was found at 10 mm radial distance from the scanner central axis. Point-source sensitivity profiles in the radial and axial directions were simulated at 1 MBq activity using the Monte-Carlo code GATE. They indicated that monolithic designs increase the sensitivity roughly by a factor of two compared to pixellated designs. NECR curves simulated for these scanner designs show no significant degradation of the performance for activities up to 40 MBq

  10. A monolithic integrated low-voltage deep brain stimulator with wireless power and data transmission

    Science.gov (United States)

    Zhang, Zhang; Ye, Tan; Jianmin, Zeng; Xu, Han; Xin, Cheng; Guangjun, Xie

    2016-09-01

    A monolithic integrated low-voltage deep brain stimulator with wireless power and data transmission is presented. Data and power are transmitted to the stimulator by mutual inductance coupling, while the in-vitro controller encodes the stimulation parameters. The stimulator integrates the digital control module and can generate the bipolar current with equal amplitude in four channels. In order to reduce power consumption, a novel controlled threshold voltage cancellation rectifier is proposed in this paper to provide the supply voltage of the stimulator. The monolithic stimulator was fabricated in a SMIC 0.18 μm 1-poly 6-metal mixed-signal CMOS process, occupying 0.23 mm2, and consumes 180 μW on average. Compared with previously published stimulators, this design has advantages of large stimulated current (0-0.8 mA) with the double low-voltage supply (1.8 and 3.3 V), and high-level integration. Project supported by the National Natural Science Foundation of China (Nos. 61404043, 61401137), the Key Laboratory of Infrared Imaging Materials and Detectors, Shanghai Institute of Technical Physics, Chinese Academy of Sciences (Nos. IIMDKFJJ-13-06, IIMDKFJJ-14-03), and the Fundamental Research Funds for the Central Universities (No. 2015HGZX0026).

  11. Silver-coated monolithic columns for separation in radiopharmaceutical applications.

    Science.gov (United States)

    Sedlacek, Ondrej; Kucka, Jan; Svec, Frantisek; Hruby, Martin

    2014-04-01

    In this study, we demonstrate the preparation of a macroporous monolithic column containing anchored silver nanoparticles and its use for the elimination of excess radioiodine from the radiolabeled pharmaceutical. The poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith was first functionalized with cystamine and the free thiol groups liberated by reaction with borohydride. In-house-prepared silver nanoparticles were then attached by interaction with the surface thiols. The deiodization process was demonstrated with the commonly used radiopharmaceutical m-iodobenzylguanidine labeled with radionuclide iodine-125. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Numerical Simulation of Fluid Dynamics in a Monolithic Column

    Directory of Open Access Journals (Sweden)

    Kazuhiro Yamamoto

    2017-01-01

    Full Text Available As for the measurement of polycyclic aromatic hydrocarbons (PAHs, ultra-performance liquid chromatography (UPLC is used for PAH identification and densitometry. However, when a solvent containing a substance to be identified passes through a column of UPLC, a dedicated high-pressure-proof device is required. Recently, a liquid chromatography instrument using a monolithic column technology has been proposed to reduce the pressure of UPLC. The present study tested five types of monolithic columns produced in experiments. To simulate the flow field, the lattice Boltzmann method (LBM was used. The velocity profile was discussed to decrease the pressure drop in the ultra-performance liquid chromatography (UPLC system.

  13. Paladin Enterprises: Monolithic particle physics models global climate.

    CERN Multimedia

    2002-01-01

    Paladin Enterprises presents a monolithic particle model of the universe which will be used by them to build an economical fusion energy system. The model is an extension of the work done by James Clerk Maxwell. Essentially, gravity is unified with electro-magnetic forces and shown to be a product of a closed loop current system, i.e. a particle - monolithic or sub atomic. This discovery explains rapid global climate changes which are evident in the geological record and also provides an explanation for recent changes in the global climate.

  14. Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns.

    Science.gov (United States)

    Elshiyab, Shareen H; Nawafleh, Noor; Öchsner, Andreas; George, Roy

    2018-02-01

    The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between 5℃ and 55℃. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments.

  15. Constitutive Theory Developed for Monolithic Ceramic Materials

    Science.gov (United States)

    Janosik, Lesley A.

    1998-01-01

    with these service conditions by developing a multiaxial viscoplastic constitutive model that accounts for time-dependent hereditary material deformation (such as creep and stress relaxation) in monolithic structural ceramics. Using continuum principles of engineering mechanics, we derived the complete viscoplastic theory from a scalar dissipative potential function.

  16. Influence of implant position on clinical crown length and peri-implant soft tissue dimensions at implant-supported single crowns replacing maxillary central incisors

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2013-01-01

    The aims of the present study were to evaluate the influence of implant position on clinical crown length and marginal soft tissue dimensions at implant-supported single crowns of maxillary central incisors, and to validate the papilla index score (PIS). Twenty-five patients, who had lost one...... as controls. Paired sample t-testand Pearson´s correlation analysis were used to analyze implant position, dimension of crownand papilla fill.Cohen’s ¿ andSpearman correlation were used to validate the PIS.The implant-supported crown was statistically longer than the contra-lateral tooth......, and there was significant correlation between the oro-facial position of the implant and the crown length difference (r=.607, p=.001). The distalpapilla was significantly shorter than the mesialpapilla at implant-supported crowns (ptooth (p=.415...

  17. Dual CARS and SHG image acquisition scheme that combines single central fiber and multimode fiber bundle to collect and differentiate backward and forward generated photons

    Science.gov (United States)

    Weng, Sheng; Chen, Xu; Xu, Xiaoyun; Wong, Kelvin K.; Wong, Stephen T. C.

    2016-01-01

    In coherent anti-Stokes Raman scattering (CARS) and second harmonic generation (SHG) imaging, backward and forward generated photons exhibit different image patterns and thus capture salient intrinsic information of tissues from different perspectives. However, they are often mixed in collection using traditional image acquisition methods and thus are hard to interpret. We developed a multimodal scheme using a single central fiber and multimode fiber bundle to simultaneously collect and differentiate images formed by these two types of photons and evaluated the scheme in an endomicroscopy prototype. The ratio of these photons collected was calculated for the characterization of tissue regions with strong or weak epi-photon generation while different image patterns of these photons at different tissue depths were revealed. This scheme provides a new approach to extract and integrate information captured by backward and forward generated photons in dual CARS/SHG imaging synergistically for biomedical applications. PMID:27375938

  18. An analysis of reliability and validity of the papilla index score of implant-supported single crowns of maxillary central incisors

    DEFF Research Database (Denmark)

    Peng, Min; Fei, Wei; Hosseini, Mandana

    2012-01-01

    Objectives: To test the reliability and validity of the papilla index scores of the implant-supported single crowns (ISSCs) of maxillary central incisors. Materials and Methods: Twenty-five patients with 25 ISSCs were included. Two prosthodontists evaluated the papilla index score (PIS) of three...... fill percent (PP) was calculated. The validity of PIS was tested against the corresponding papilla fill percent (PP) by using the Spearman correlation analysis. Results: The intra-observer agreement was >70% in 4/5 and >50% in all observations, the pooled Cohen’s ¿ was 0.64 and 0.70 for two observers...... inter-observer agreement. The PIS score demonstrated significant correlation to the corresponding PP value (rs=.567, p=.000). Conclusions: The feasibility, reliability and validity of the PIS made the parameter useful for quality control of the pri-implant soft tissue of ISSCs....

  19. Development and applications of femtosecond monolithic Yb-doped fiber chirped-pulse amplifiers

    International Nuclear Information System (INIS)

    Zhu, L.

    2011-01-01

    solid-state oscillator seeder in terms of the pulse fidelity and pulse energy while offering the robustness of a fiber oscillator. Finally, a broadband difference-frequency converter is demonstrated, by employing the monolithic Yb-doped FCPA system as a robust and efficient front-end for a two-stage optical parametric amplifier (OPA) system. This converter is able to emit carrier-envelope-offset-free pulses with energy of tens of ∼nJ that is tunable in the wavelength range from 1200 nm to beyond 2 um. The measurement results of the OPA output phase stability, through spectral broadening in a piece of single mode fiber together with a so-called f-to-2f interferometer, prove the passive carrier-envelope-phase stability nature of this OPA system. (author)

  20. A Study of Cortical Excitability, Central Motor Conduction, and Cortical Inhibition Using Single Pulse Transcranial Magnetic Stimulation in Patients with Early Frontotemporal and Alzheimer's Dementia.

    Science.gov (United States)

    Chandra, Sadanandavalli Retnaswami; Issac, Thomas Gregor; Nagaraju, B C; Philip, Mariamma

    2016-01-01

    Degenerative cortical dementias affect several million people worldwide. Early diagnosis and categorization are essential for initiating appropriate pharmacological and nonpharmacological treatment so that deterioration can be postponed, and disability adjusted life years can be saved both for the patient and for the caregiver. Therefore, an early, simple, noninvasive biomarker will serve as a boon. Patients who satisfied probable Alzheimer's disease (AD) or frontotemporal dementia (FTD) using international consensus criteria for FTD and National Institute of Neurological Disorders and Stroke-AD and Related Disorders Association criteria for AD were evaluated using single pulse transcranial magnetic stimulation with figure of eight coil and motor evoked potential from right first dorsal interossei. Resting threshold (MT), central motor conduction time (CMCT), and silent period (SP) were evaluated. Resting MT and SP are reduced in patients with Alzheimer's disease whereas CMCT is prolonged in patients with FTD and SP is in the lower limit of normal in both conditions. The patterns of central motor conduction and MT are distinctly different in patients with early Alzheimer's disease (AD) and FTD.

  1. Components for monolithic fiber chirped pulse amplification laser systems

    Science.gov (United States)

    Swan, Michael Craig

    The first portion of this work develops techniques for generating femtosecond-pulses from conventional fabry-perot laser diodes using nonlinear-spectral-broadening techniques in Yb-doped positive dispersion fiber ampliers. The approach employed an injection-locked fabry-perot laser diode followed by two stages of nonlinear-spectral-broadening to generate sub-200fs pulses. This thesis demonstrated that a 60ps gain-switched fabry-perot laser-diode can be injection-locked to generate a single-longitudinal-mode pulse and compressed by nonlinear spectral broadening to 4ps. Two problems have been identified that must be resolved before moving forward with this approach. First, gain-switched pulses from a standard diode-laser have a number of characteristics not well suited for producing clean self-phase-modulation-broadened pulses, such as an asymmetric temporal shape, which has a long pulse tail. Second, though parabolic pulse formation occurs for any arbitrary temporal input pulse profile, deviation from the optimum parabolic input results in extensively spectrally modulated self-phase-modulation-broadened pulses. In conclusion, the approach of generating self-phase-modulation-broadened pulses from pulsed laser diodes has to be modified from the initial approach explored in this thesis. The first Yb-doped chirally-coupled-core ber based systems are demonstrated and characterized in the second portion of this work. Robust single-mode performance independent of excitation or any other external mode management techniques have been demonstrated in Yb-doped chirally-coupled-core fibers. Gain and power efficiency characteristics are not compromised in any way in this novel fiber structure up to the 87W maximum power achieved. Both the small signal gain at 1064nm of 30.3dB, and the wavelength dependence of the small signal gain were comparable to currently deployed large-mode-area-fiber technology. The efficiencies of the laser and amplifier were measured to be 75% and 54

  2. Towards using a Monolithic Active Pixel Sensor for in vivo beam monitoring of Intensity Modulated Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Page, R.F., E-mail: ryan.page@bristol.ac.uk [H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Abbott, N.L.; Davies, J.; Dyke, E.L.; Randles, H.J. [H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Velthuis, J.J. [H.H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol BS8 1TL (United Kingdom); Bristol Haematology and Oncology Centre, University Hospitals Bristol, NHS Foundation Trust (United Kingdom); Fletcher, S.; Gregory, S.D.; Hall, C.; John, A.; Lawrence, H.; Stevens, P.H. [Bristol Haematology and Oncology Centre, University Hospitals Bristol, NHS Foundation Trust (United Kingdom); Hugtenburg, R.P.; Tunbridge, V. [Swansea University, Singleton Park, Swansea SA2 8PP (United Kingdom)

    2013-12-11

    The use of Intensity Modulated Radiotherapy (IMRT) for cancer treatments is entering wider use. These treatments involve using a complex configuration of field modifying components, known as Multileaf Collimators (MLC), to dynamically shape the beam. A treatment consists of a sequence of irregular shaped fields, which means real time monitoring and verification is essential. In the current framework the treatment plans are verified before the patient is treated, but not during. The aim of our collaboration is to monitor the treatment being given to the patient. This is achieved by placing a camera system using an ultra-thin Monolithic Active Pixel Sensor (MAPS) upstream of the patient. -- Highlights: •A Monolithic Active Pixel Sensor was used to measure the shape of an IMRT field. •The sensor was positioned upstream of the patient causing only a ∼ 0.1% attenuation. •Edges of Multileaf Collimators were determined using edge reconstruction techniques. •The reconstructed edge precision was measured to be 52±4μm for a single frame. •Edge positions from the sensor and film are compared and found to be within error.

  3. Design of a Modular Monolithic Implicit Solver for Multi-Physics Applications

    Science.gov (United States)

    Carton De Wiart, Corentin; Diosady, Laslo T.; Garai, Anirban; Burgess, Nicholas; Blonigan, Patrick; Ekelschot, Dirk; Murman, Scott M.

    2018-01-01

    The design of a modular multi-physics high-order space-time finite-element framework is presented together with its extension to allow monolithic coupling of different physics. One of the main objectives of the framework is to perform efficient high- fidelity simulations of capsule/parachute systems. This problem requires simulating multiple physics including, but not limited to, the compressible Navier-Stokes equations, the dynamics of a moving body with mesh deformations and adaptation, the linear shell equations, non-re effective boundary conditions and wall modeling. The solver is based on high-order space-time - finite element methods. Continuous, discontinuous and C1-discontinuous Galerkin methods are implemented, allowing one to discretize various physical models. Tangent and adjoint sensitivity analysis are also targeted in order to conduct gradient-based optimization, error estimation, mesh adaptation, and flow control, adding another layer of complexity to the framework. The decisions made to tackle these challenges are presented. The discussion focuses first on the "single-physics" solver and later on its extension to the monolithic coupling of different physics. The implementation of different physics modules, relevant to the capsule/parachute system, are also presented. Finally, examples of coupled computations are presented, paving the way to the simulation of the full capsule/parachute system.

  4. LePix—A high resistivity, fully depleted monolithic pixel detector

    International Nuclear Information System (INIS)

    Giubilato, P.; Bisello, D.; Chalmet, P.; Denes, P.; Kloukinas, K.; Mattiazzo, S.; Marchioro, A.; Mugnier, H.; Pantano, D.; Potenza, A.; Rivetti, A.; Rousset, J.; Snoeys, W.; Tindall, C.

    2013-01-01

    The LePix project explores monolithic pixel sensors fabricated in a 90 nm CMOS technology built over a lightly doped substrate. This approach keeps the advantages usually offered by Monolithic Active Pixel Sensors (MAPS), like a low input capacitance, having a single piece detector and using a standard CMOS production line, and adds the benefit of charge collection by drift from a depleted region several tens of microns deep into the substrate, therefore providing an excellent signal to noise ratio and a radiation tolerance superior to conventional un-depleted MAPS. Such sensors are expected to offer significant cost savings and reduction of power consumption for the same performance, leading to the use of much less material in the detector (less cooling and less copper), addressing one of the main limitations of present day particle tracking systems. The latest evolution of the project uses detectors thinned down to 50 μm to obtain back illuminated sensors operated in full depletion mode. By back-processing the chip and collecting the charge from the full substrate it is hence possible to efficiently detect soft X-rays up to 10 keV. Test results from first successfully processed detectors will be presented and discussed

  5. A new high-voltage interconnection shielding method for SOI monolithic ICs

    Science.gov (United States)

    Zhang, Long; Zhu, Jing; Sun, Weifeng; Huang, Xuequan; Zhao, Minna; Chen, Jiajun; Shi, Longxing; Chen, Jian; Ding, Desheng

    2017-07-01

    The high-voltage interconnection (HVI) issue becomes severe in the high-voltage monolithic ICs when single-layer metal is used for lowering the cost. This paper proposes a dual deep-oxide trenches (DDOT) structure for 500 V Silicon-on-Insulator Lateral Insulated Gate Bipolar Transistor (SOI-LIGBT) to shield the influence of HVI on the breakdown voltage. Compared with the conventional DDOT structure, HVI region of the proposed DDOT structure is shrunk by employing a shallow trench (T1) and a deep trench (T2). Besides the breakdown mechanism in the off-state, the current density and impact ionization rate distributions in the on-state of the proposed structure are also investigated. The experiments demonstrate that the proposed DDOT structure can fully shield the influence of HVI with significant reduction in the area of silicon region beneath the HVI. With almost the same off-state breakdown voltage (BVoff) of 550 V as the conventional DDOT structure, the length of the silicon region under the HVI in the proposed structure is shortened from 45 μm to 15 μm. Meanwhile, no on-state breakdown voltage (BVon) degradation is observed according to the measured results. The new method proposed in this work can also be used for other types of high-voltage devices such as LDMOS and free-wheeling diode in SOI Monolithic ICs.

  6. The preparation of microfluidic architecture with monolithic materials using a dual porous silica structure.

    Science.gov (United States)

    Birch, Christopher; Esfahani, Mohammad Mehdi Nasr; Shaw, Kirsty J; Kemp, Cordula; Haswell, Stephen James; Dyer, Charlotte

    2017-11-01

    A microfluidic device (MD) has been developed which features a porous silica (PS) monolithic disk synthesized from tetramethyl orthosilicate, incorporated into the device post-fabrication and sealed in place with a second PS monolithic layer, synthesized from potassium silicate. This dual porous silica (DPS) structure provides a pathway for sample introduction to the MD and offers an ideal platform for solid phase extraction (SPE) methodologies which can be rapidly and efficiently integrated into a chip-based format. All silica disk manufacture and functionalization was carried out in batch to provide a readily scalable method of production. Application of this design for processing samples was demonstrated using two alternative nucleic acid purification chemistries, yielding polymerase chain reaction amplifiable DNA extracted from 150 μL of human urine in less than 35 min. It is proposed that this DPS system could be further developed for a diverse range of chip-based SPE applications, providing an interface facilitating sample delivery and enabling SPE on-chip. Furthermore, to the author's knowledge it is the first reporting of two different types of PS amalgamated in a single MD. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Monolithic wide tunable laser diodes for gas sensing at 2100 nm

    Science.gov (United States)

    Koslowski, Nicolas; Heger, Andreas; Roessner, Karl; Legge, Michael; Koeth, Johannes; Hildebrandt, Lars

    2013-03-01

    Novel monolithic widely tunable laser diodes in the 2.1μm wavelength region based on GaSb / AlGaAsSb are presented. Using the concept of a lateral binary superimposed (BSG) grating structures and multisegment Verniertuning, stable single-mode output is realized at discrete wavelength channels in the 2060 nm - 2140 nm region. A total tuning above 80 nm in six channels is demonstrated. In every wavelength channel, the output wavelength can be tuned by current and temperature. Each wavelength channel offers up to 6 nm of mode hop free tuning, making this novel widely tunable laser highly attractive as a monolithic light source for multiple-gas sensing or liquid detection purposes. The wavelength channels can be arbitrarily placed within the material gain allowing BSG lasers to sweep e.g. over several gas absorption line within 80 nm. Within a wavelength channel, the widely tunable lasers show DFB like spectral performance with average side-mode suppression-ratios above 40 dB, output power of up to 15 mW at 25°C. Also temperature and current tuning coefficients are comparable to those of DFB lasers. This paper will present an overview of laser concept, performance data and applications.

  8. Monolithically integrated tri-axis shock accelerometers with MHz-level high resonant-frequency

    Science.gov (United States)

    Zou, Hongshuo; Wang, Jiachou; Chen, Fang; Bao, Haifei; Jiao, Ding; Zhang, Kun; Song, Zhaohui; Li, Xinxin

    2017-07-01

    This paper reports a novel monolithically integrated tri-axis high-shock accelerometer with high resonant-frequency for the detection of a broad frequency-band shock signal. For the first time, a resonant-frequency as high as about 1.4 MHz is designed for all the x-, y- and z-axis accelerometers of the integrated tri-axis sensor. In order to achieve a wide frequency-band detection performance, all the three sensing structures are designed into an axially compressed/stretched tiny-beam sensing scheme, where the p  +  -doped tiny-beams are connected into a Wheatstone bridge for piezoresistive output. By using ordinary (1 1 1) silicon wafer (i.e. non-SOI wafer), a single-wafer based fabrication technique is developed to monolithically integrate the three sensing structures for the tri-axis sensor. Testing results under high-shock acceleration show that each of the integrated three-axis accelerometers exhibit about 1.4 MHz resonant-frequency and 0.2-0.4 µV/V/g sensitivity. The achieved high frequencies for all the three sensing units make the tri-axis sensor promising in high fidelity 3D high-shock detection applications.

  9. LePix-A high resistivity, fully depleted monolithic pixel detector

    CERN Document Server

    Giubilato, P; Mugnier, H; Bisello, D; Marchioro, A; Snoeys, W; Denes, P; Pantano, D; Rousset, J; Mattiazzo, S; Kloukinas, K; Potenza, A; Rivetti, A; Chalmet, P

    2013-01-01

    The LePix project explores monolithic pixel sensors fabricated in a 90 nm CMOS technology built over a lightly doped substrate. This approach keeps the advantages usually offered by Monolithic Active Pixel Sensors (MAPS), like a low input capacitance, having a single piece detector and using a standard CMOS production line, and adds the benefit of charge collection by drift from a depleted region several tens of microns deep into the substrate, therefore providing an excellent signal to noise ratio and a radiation tolerance superior to conventional un-depleted MAPS. Such sensors are expected to offer significant cost savings and reduction of power consumption for the same performance, leading to the use of much less material in the detector (less cooling and less copper), addressing one of the main limitations of present day particle tracking systems. The latest evolution of the project uses detectors thinned down to 50 mu m to obtain back illuminated sensors operated in full depletion mode. By back processin...

  10. Broadband 2-µm emission on silicon chips: monolithically integrated Holmium lasers.

    Science.gov (United States)

    Li, Nanxi; Magden, Emir Salih; Su, Zhan; Singh, Neetesh; Ruocco, Alfonso; Xin, Ming; Byrd, Matthew; Callahan, Patrick T; Bradley, Jonathan D B; Baiocco, Christopher; Vermeulen, Diedrik; Watts, Michael R

    2018-02-05

    Laser sources in the mid-infrared are of great interest due to their wide applications in detection, sensing, communication and medicine. Silicon photonics is a promising technology which enables these laser devices to be fabricated in a standard CMOS foundry, with the advantages of reliability, compactness, low cost and large-scale production. In this paper, we demonstrate a holmium-doped distributed feedback laser monolithically integrated on a silicon photonics platform. The Al 2 O 3 :Ho 3+ glass is used as gain medium, which provides broadband emission around 2 µm. By varying the distributed feedback grating period and Al 2 O 3 :Ho 3+ gain layer thickness, we show single mode laser emission at wavelengths ranging from 2.02 to 2.10 µm. Using a 1950 nm pump, we measure a maximum output power of 15 mW, a slope efficiency of 2.3% and a side-mode suppression ratio in excess of 50 dB. The introduction of a scalable monolithic light source emitting at > 2 µm is a significant step for silicon photonic microsystems operating in this highly promising wavelength region.

  11. Evaluation of the deflected mode of the monolithic span pieces and preassembled slabs combined action

    Science.gov (United States)

    Roshchina, Svetlana; Ezzi, Hisham; Shishov, Ivan; Lukin, Mikhail; Sergeev, Michael

    2017-10-01

    In single-story industrial buildings, the cost of roof covering comprises 40-55% of the total cost of the buildings. Therefore, research, development and application of new structural forms of reinforced concrete rafter structures, that allow to reduce material consumption and reduce the sub-assembly weight of structures, are the main tasks in the field of improving the existing generic solutions. The article suggests a method for estimating the relieving effect in the rafter structure as the result of combined deformation of the roof slabs with the end arrises. Calculated and experimental method for determining the stress and strain state of the rafter structure upper belt and the roof slabs with regard to their rigid connection has been proposed. A model of a highly effective roof structure providing a significant reduction in the construction height of the roofing and the cubic content of the building at the same time allowing to include the end arrises and a part of the slabs shelves with the help of the monolithic concrete has been proposed. The proposed prefabricated monolithic concrete rafter structure and its rigid connection with ribbed slabs allows to reduce the consumption of the prestressed slabs reinforcement by 50%.

  12. Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow

    Directory of Open Access Journals (Sweden)

    Peng Jiang

    2015-12-01

    Full Text Available This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system.

  13. Comparison of monolithic silica and polymethacrylate capillary columns for LC

    Czech Academy of Sciences Publication Activity Database

    Moravcová, D.; Jandera, P.; Urban, J.; Planeta, Josef

    2004-01-01

    Roč. 27, 10-11 (2004), s. 789-800 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GA203/02/0023 Keywords : monolithic column s * capillary HPLC * column testing Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 1.927, year: 2004

  14. Characterization of polymer monolithic stationary phases for capillary HPLC

    Czech Academy of Sciences Publication Activity Database

    Moravcová, D.; Jandera, P.; Urban, J.; Planeta, Josef

    2003-01-01

    Roč. 26, č. 11 (2003), s. 1005-1016 ISSN 1615-9306 R&D Projects: GA ČR GA203/02/0023 Institutional research plan: CEZ:AV0Z4031919; CEZ:MSM 253100002 Keywords : monolithic column s * capillary HPLC * column testing Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.108, year: 2003

  15. Monolithic CMOS pixel detector for international linear collider ...

    Indian Academy of Sciences (India)

    the vertex detector elements and thus existing CCDs are not adequate. New CCD architectures are ... sizes of the 292 detector elements (chips) are summarized in tables 1 and 2. The baseline time structure of ... an R&D contract, we developed a conceptual design for a monolithic CMOS device. (chip) that achieves the ILC ...

  16. Monolithic CMOS pixel detector for international linear collider ...

    Indian Academy of Sciences (India)

    Toggle navigation. Logo of the Indian Academy of Sciences. Indian Academy of Sciences. Home · About ... Home; Journals; Pramana – Journal of Physics; Volume 69; Issue 6. Monolithic CMOS pixel detector for international linear ... Keywords. Vertex detector; international linear collider; linear collider; high energy physics.

  17. CMOS Monolithic Active Pixel Sensors (MAPS): developments and future outlook

    NARCIS (Netherlands)

    Turchetta, R.; Fant, A.; Gasiorek, P.; Esbrand, C.; Griffiths, J.A.; Metaxas, M.G.; Royle, G.J.; Speller, R.; Venanzi, C.; van der Stelt, P.F.; Verheij, H.; Li, G.; Theodoridis, S.; Georgiou, H.; Cavouras, D.; Hall, G.; Noy, M.; Jones, J.; Leaver, J.; Machin, D.; Greenwood, S.; Khaleeq, M.; Schulerud, H.; Østby, J.M.; Triantis, F.; Asimidis, A.; Bolanakis, D.; Manthos, N.; Longo, R.; Bergamaschi, A.

    2007-01-01

    Re-invented in the early 1990s, on both sides of the Atlantic, Monolithic Active Pixel Sensors (MAPS) in a CMOS technology are today the most sold solid-state imaging devices, overtaking the traditional technology of Charge-Coupled Devices (CCD). The slow uptake of CMOS MAPS started with low-end

  18. Cyclodextrin-Functionalized Monolithic Capillary Columns: Preparation and Chiral Applications.

    Science.gov (United States)

    Adly, Frady G; Antwi, Nana Yaa; Ghanem, Ashraf

    2016-02-01

    In this review, the recently reported approaches for the preparation of cyclodextrin-functionalized capillary monolithic columns are highlighted, with few applications in chiral separations using capillary liquid chromatography (CLC) and capillary electrochromatography (CEC). Chirality 28:97-109, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  19. A Monolithically-Integrated μGC Chemical Sensor System

    Directory of Open Access Journals (Sweden)

    Davor Copic

    2011-06-01

    Full Text Available Gas chromatography (GC is used for organic and inorganic gas detection with a range of applications including screening for chemical warfare agents (CWA, breath analysis for diagnostics or law enforcement purposes, and air pollutants/indoor air quality monitoring of homes and commercial buildings. A field-portable, light weight, low power, rapid response, micro-gas chromatography (μGC system is essential for such applications. We describe the design, fabrication and packaging of mGC on monolithically-integrated Si dies, comprised of a preconcentrator (PC, μGC column, detector and coatings for each of these components. An important feature of our system is that the same mechanical micro resonator design is used for the PC and detector. We demonstrate system performance by detecting four different CWA simulants within 2 min. We present theoretical analyses for cost/power comparisons of monolithic versus hybrid μGC systems. We discuss thermal isolation in monolithic systems to improve overall performance. Our monolithically-integrated μGC, relative to its hybrid cousin, will afford equal or slightly lower cost, a footprint that is 1/2 to 1/3 the size and an improved resolution of 4 to 25%.

  20. A monolithically-integrated μGC chemical sensor system.

    Science.gov (United States)

    Manginell, Ronald P; Bauer, Joseph M; Moorman, Matthew W; Sanchez, Lawrence J; Anderson, John M; Whiting, Joshua J; Porter, Daniel A; Copic, Davor; Achyuthan, Komandoor E

    2011-01-01

    Gas chromatography (GC) is used for organic and inorganic gas detection with a range of applications including screening for chemical warfare agents (CWA), breath analysis for diagnostics or law enforcement purposes, and air pollutants/indoor air quality monitoring of homes and commercial buildings. A field-portable, light weight, low power, rapid response, micro-gas chromatography (μGC) system is essential for such applications. We describe the design, fabrication and packaging of μGC on monolithically-integrated Si dies, comprised of a preconcentrator (PC), μGC column, detector and coatings for each of these components. An important feature of our system is that the same mechanical micro resonator design is used for the PC and detector. We demonstrate system performance by detecting four different CWA simulants within 2 min. We present theoretical analyses for cost/power comparisons of monolithic versus hybrid μGC systems. We discuss thermal isolation in monolithic systems to improve overall performance. Our monolithically-integrated μGC, relative to its hybrid cousin, will afford equal or slightly lower cost, a footprint that is 1/2 to 1/3 the size and an improved resolution of 4 to 25%.

  1. Status of the Monolithic Suspensions for Advanced Virgo

    Science.gov (United States)

    Travasso, F.; Virgo Collaboration

    2018-02-01

    Successfully implemented in GEO and Virgo+, the monolithic suspensions are one of the most important upgrades in the second generation of gravitational wave interferometric detectors, including Advanced LIGO (aLIGO) and Advanced Virgo (AdV). Characterized by a very low thermal noise, monolithic suspensions are essential for improving the interferometers sensitivity at low frequencies (10-100Hz). In Advanced Virgo their installation was delayed because of a contamination problem in the vacuum system: dust produced by scroll pumps was injected in the main vacuum chambers during the venting processes, damaging the fibers and ultimately causing their repeated failure. The effort to explain and resolve this issue was useful to further confirm the suspensions’ reliability and our control on the production process. Moreover, we developed and implemented new tools and procedures to certify each part of the monolithic suspensions. In the meanwhile, in order to join aLIGO during its second Observation Run (O2), a temporary steel suspension was implemented, based on the initial Virgo design. That solution allowed us to contribute to the first three-detector observation of a gravitational wave (GW) ([1]), and to the first observation of a coalescing neutron star binary ([2]) In the near future the monolithic suspensions will be reinstalled along with additional upgrades of Virgo.

  2. Methacrylate monolithic capillary columns for gradient peptide separations

    NARCIS (Netherlands)

    Pruim, P.; Öhman, M.; Huo, Y.; Schoenmakers, P.J.; Kok, W.Th.

    2008-01-01

    For the separation of peptides with gradient-elution liquid chromatography a poly(butyl methacrylate-co-ethylene dimethacrylate) (BMA) monolithic capillary column was prepared and tested. The conditional peak capacity was used as a metric for the performance of this column, which was compared with a

  3. High density fuels using dispersion and monolithic fuel

    Energy Technology Data Exchange (ETDEWEB)

    Gomes, Daniel S.; Silva, Antonio T.; Abe, Alfredo Y.; Muniz, Rafael O.R.; Giovedi, Claudia, E-mail: dsgomes@ipen.br, E-mail: teixeira@ipen.br, E-mail: alfredo@ctmsp.mar.mil.br, E-mail: rafael.orm@gmail.com, E-mail: claudia.giovedi@ctmsp.mar.mil.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Universidade de São Paulo (USP), SP (Brazil). Departamento de Engenharia Naval e Oceânica

    2017-07-01

    Fuel plates used in high-performance research reactors need to be converted to low-enrichment uranium fuel; the fuel option based on a monolithic formulation requires alloys to contain 6 - 10 wt% Mo. In this case, the fuel plates are composed of the metallic alloy U-10Mo surrounded by a thin zirconium layer encapsulated in aluminum cladding. This study reviewed the physical properties of monolithic forms. The constraints produced during the manufacturing process were analyzed and compared to those of dispersed fuel. The bonding process used for dispersion fuels differs from the techniques applied to foil bonding used for pure alloys. The quality of monolithic plates depends on the fabrication method, which usually involves hot isostatic pressing and the thermal annealing effect of residual stress, which degrades the uranium cubic phase. The preservation of the metastable phase has considerable influence on fuel performance. The physical properties of the foil fuel under irradiation are superior to those of aluminum-dispersed fuels. The fuel meat, using zirconium as the diffusion barrier, prevents the interaction layer from becoming excessively thick. The problem with dispersed fuel is breakaway swelling with a medium fission rate. It has been observed that the fuel dispersed in aluminum was minimized in monolithic forms. The pure alloys exhibited a suitable response from a rate at least twice as much as the fission rate of dispersions. The foils can support fissile material concentration combined with a reduced swelling rate. (author)

  4. A Monolithic Perovskite Structure for Use as a Magnetic Regenerator

    DEFF Research Database (Denmark)

    Pryds, Nini; Clemens, Frank; Menon, Mohan

    2011-01-01

    and the influence of the sintering on the adiabatic temperature change, were investigated. Comparisons between the extruded monolithic structure before and after the sintering showed that an increase of the adiabatic temperature change was seen after the sintering. Furthermore, calculations show...

  5. A radiation hard bipolar monolithic front-end readout

    CERN Document Server

    Baschirotto, A; Cappelluti, I; Castello, R; Cermesoni, M; Gola, A; Pessina, G; Pistolesi, E; Rancoita, P G; Seidman, A

    1999-01-01

    A fast bipolar monolithic charge sensitive preamplifier (CSP), implemented in the monolithic 2 mu m BiCMOS technology (called HF2CMOS) was designed and built in a quad monolithic chip. Studies of radiation effects in the CSP $9 performance, from non-irradiated and up to neutron irradiation of 5.3*10/sup 14/ n/cm/sup 2/, have confirmed that the use of bipolar npn transistors is suitable for the radiation level of the future LHC collider environment. The CSP $9 presents a new circuit solution for obtaining adequate slew rate performances which results in an integral linearity better than 0.8554330n 5 V at 20 ns of shaping time, regardless of the bias current selected for the CSP. This way $9 the bias current of the CSP can be set for optimizing the power dissipation with respect to series and parallel noise, especially useful when the CSP is put in a radiation environment. A prototype test with a novel monolithic 20 ns $9 time constant RC-CR shaper, capable to sum up four inputs has been also realized, featurin...

  6. Monolithic natural gas storage delivery system based on sorbents

    Energy Technology Data Exchange (ETDEWEB)

    Hornbostel, Marc; Krishnan, Gopala N.; Sanjurjo, Angel

    2016-09-27

    The invention provides methods for producing a strong, light, sorbent-based storage/dispenser system for gases and fuels. The system comprises a porous monolithic material with an adherent strong impervious skin that is capable of storing a gas under pressure in a safe and usable manner.

  7. Study of monolithic prestressed reinforced concrete overhead road.

    Directory of Open Access Journals (Sweden)

    Ya.I. Kovalchyk

    2011-12-01

    Full Text Available Results of inspection and testing of monolithic prestressed reinforced concrete road trestle built in Kyiv are considered. The analysis of the gained results has shown that parametres correspond to the requirements of current standards on design of bridges.

  8. Monolithic CMOS pixel detector for international linear collider ...

    Indian Academy of Sciences (India)

    the vertex detector elements and thus existing CCDs are not adequate. New CCD architectures are under development [2] but have yet to achieve the required perfor- mance. For these reasons there is an increased importance on the development of monolithic CMOS pixel detectors that allow extremely fast non-sequential ...

  9. Dopamine-imprinted monolithic column for capillary electrochromatography.

    Science.gov (United States)

    Aşır, Süleyman; Sarı, Duygu; Derazshamshir, Ali; Yılmaz, Fatma; Şarkaya, Koray; Denizli, Adil

    2017-11-01

    A dopamine-imprinted monolithic column was prepared and used in capillary electrochromatography as stationary phase for the first time. Dopamine was selectively separated from aqueous solution containing the competitor molecule norepinephrine, which is similar in size and shape to the template molecule. Morphology of the dopamine-imprinted column was observed by scanning electron microscopy. The influence of the organic solvent content of mobile phase, applied pressure and pH of the mobile phase on the recognition of dopamine by the imprinted monolithic column has been evaluated, and the imprinting effect in the dopamine-imprinted monolithic polymer was verified. Developed dopamine-imprinted monolithic column resulted in excellent separation of dopamine from structurally related competitor molecule, norepinephrine. Separation was achieved in a short period of 10 min, with the electrophoretic mobility of 5.81 × 10 -5  m 2 V -1 s -1 at pH 5.0 and 500 mbar pressure. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Monolithic and Small Particle Column Materials for Application in Proteomics

    NARCIS (Netherlands)

    Rozenbrand, J.

    2012-01-01

    In this thesis the influence of the capillary liquid chromatography separation on the identification of protein digests is studied. In the first part the chromatographic parameters for silica monolithic columns are optimized to obtain a high throughput or a high separation performance. in the second

  11. Environmentally Benign Production of Stretchable and Robust Superhydrophobic Silicone Monoliths.

    Science.gov (United States)

    Davis, Alexander; Surdo, Salvatore; Caputo, Gianvito; Bayer, Ilker S; Athanassiou, Athanassia

    2018-01-24

    Superhydrophobic materials hold an enormous potential in sectors as important as aerospace, food industries, or biomedicine. Despite this great promise, the lack of environmentally friendly production methods and limited robustness remain the two most pertinent barriers to the scalability, large-area production, and widespread use of superhydrophobic materials. In this work, highly robust superhydrophobic silicone monoliths are produced through a scalable and environmentally friendly emulsion technique. It is first found that stable and surfactantless water-in-polydimethylsiloxane (PDMS) emulsions can be formed through mechanical mixing. Increasing the internal phase fraction of the precursor emulsion is found to increase porosity and microtexture of the final monoliths, rendering them superhydrophobic. Silica nanoparticles can also be dispersed in the aqueous internal phase to create micro/nanotextured monoliths, giving further improvements in superhydrophobicity. Due to the elastomeric nature of PDMS, superhydrophobicity can be maintained even while the material is mechanically strained or compressed. In addition, because of their self-similarity, the monoliths show outstanding robustness to knife-scratch, tape-peel, and finger-wipe tests, as well as rigorous sandpaper abrasion. Superhydrophobicity was also unchanged when exposed to adverse environmental conditions including corrosive solutions, UV light, extreme temperatures, and high-energy droplet impact. Finally, important properties for eventual adoption in real-world applications including self-cleaning, stain-repellence, and blood-repellence are demonstrated.

  12. Mechanical monolithic horizontal sensor for low frequency seismic noise measurement.

    Science.gov (United States)

    Acernese, Fausto; Giordano, Gerardo; Romano, Rocco; De Rosa, Rosario; Barone, Fabrizio

    2008-07-01

    This paper describes a mechanical monolithic horizontal sensor for geophysical applications developed at the University of Salerno. The instrument is basically a monolithic tunable folded pendulum, shaped with precision machining and electric discharge machining, that can be used both as seismometer and, in a force-feedback configuration, as accelerometer. The monolithic mechanical design and the introduction of laser interferometric techniques for the readout implementation makes it a very compact instrument, very sensitive in the low frequency seismic noise band, with a very good immunity to environmental noises. Many changes have been produced since last version (2007), mainly aimed to the improvement of the mechanics and of the optical readout of the instrument. In fact, we have developed and tested a prototype with elliptical hinges and mechanical tuning of the resonance frequency together with a laser optical lever and a new laser interferometer readout system. The theoretical sensitivity curve for both laser optical lever and laser interferometric readouts, evaluated on the basis of suitable theoretical models, shows a very good agreement with the experimental measurements. Very interesting scientific result is the measured natural resonance frequency of the instrument of 70 mHz with a Q=140 in air without thermal stabilization. This result demonstrates the feasibility of a monolithic folded pendulum sensor with a natural resonance frequency of the order of millihertz with a more refined mechanical tuning.

  13. Scalable Fabrication of Photochemically Reduced Graphene-Based Monolithic Micro-Supercapacitors with Superior Energy and Power Densities.

    Science.gov (United States)

    Wang, Sen; Wu, Zhong-Shuai; Zheng, Shuanghao; Zhou, Feng; Sun, Chenglin; Cheng, Hui-Ming; Bao, Xinhe

    2017-04-25

    Micro-supercapacitors (MSCs) hold great promise as highly competitive miniaturized power sources satisfying the increased demand of smart integrated electronics. However, single-step scalable fabrication of MSCs with both high energy and power densities is still challenging. Here we demonstrate the scalable fabrication of graphene-based monolithic MSCs with diverse planar geometries and capable of superior integration by photochemical reduction of graphene oxide/TiO 2 nanoparticle hybrid films. The resulting MSCs exhibit high volumetric capacitance of 233.0 F cm -3 , exceptional flexibility, and remarkable capacity of modular serial and parallel integration in aqueous gel electrolyte. Furthermore, by precisely engineering the interface of electrode with electrolyte, these monolithic MSCs can operate well in a hydrophobic electrolyte of ionic liquid (3.0 V) at a high scan rate of 200 V s -1 , two orders of magnitude higher than those of conventional supercapacitors. More notably, the MSCs show landmark volumetric power density of 312 W cm -3 and energy density of 7.7 mWh cm -3 , both of which are among the highest values attained for carbon-based MSCs. Therefore, such monolithic MSC devices based on photochemically reduced, compact graphene films possess enormous potential for numerous miniaturized, flexible electronic applications.

  14. Highly luminescent and ultrastable CsPbBr{sub 3} perovskite quantum dots incorporated into a silica/alumina monolith

    Energy Technology Data Exchange (ETDEWEB)

    Li, Zhichun; Kong, Long; Huang, Shouqiang; Li, Liang [School of Environmental Science and Engineering, Shanghai Jiao Tong University (China)

    2017-07-03

    We successfully prepared QDs incorporated into a silica/alumina monolith (QDs-SAM) by a simple sol-gel reaction of an Al-Si single precursor with CsPbBr{sub 3} QDs blended in toluene solution, without adding water and catalyst. The resultant transparent monolith exhibits high photoluminescence quantum yields (PLQY) up to 90 %, and good photostability under strong illumination of blue light for 300 h. We show that the preliminary ligand exchange of didodecyl dimethyl ammonium bromide (DDAB) was very important to protect CsPbBr{sub 3} QDs from surface damages during the sol-gel reaction, which not only allowed us to maintain the original optical properties of CsPbBr{sub 3} QDs but also prevented the aggregation of QDs and made the monolith transparent. The CsPbBr{sub 3} QDs-SAM in powder form was easily mixed into the resins and applied as color-converting layer with curing on blue light-emitting diodes (LED). The material showed a high luminous efficacy of 80 lm W{sup -1} and a narrow emission with a full width at half maximum (FWHM) of 25 nm. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  15. Highly Luminescent and Ultrastable CsPbBr3 Perovskite Quantum Dots Incorporated into a Silica/Alumina Monolith.

    Science.gov (United States)

    Li, Zhichun; Kong, Long; Huang, Shouqiang; Li, Liang

    2017-07-03

    We successfully prepared QDs incorporated into a silica/alumina monolith (QDs-SAM) by a simple sol-gel reaction of an Al-Si single precursor with CsPbBr 3 QDs blended in toluene solution, without adding water and catalyst. The resultant transparent monolith exhibits high photoluminescence quantum yields (PLQY) up to 90 %, and good photostability under strong illumination of blue light for 300 h. We show that the preliminary ligand exchange of didodecyl dimethyl ammonium bromide (DDAB) was very important to protect CsPbBr 3 QDs from surface damages during the sol-gel reaction, which not only allowed us to maintain the original optical properties of CsPbBr 3 QDs but also prevented the aggregation of QDs and made the monolith transparent. The CsPbBr 3 QDs-SAM in powder form was easily mixed into the resins and applied as color-converting layer with curing on blue light-emitting diodes (LED). The material showed a high luminous efficacy of 80 lm W -1 and a narrow emission with a full width at half maximum (FWHM) of 25 nm. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. A novel application of methacrylate based short monolithic columns: concentrating Potato spindle tuber viroid from water samples.

    Science.gov (United States)

    Ruščić, Jelena; Gutiérrez-Aguirre, Ion; Urbas, Lidija; Kramberger, Petra; Mehle, Nataša; Škorić, Dijana; Barut, Miloš; Ravnikar, Maja; Krajačić, Mladen

    2013-01-25

    Potato spindle tuber viroid (PSTVd) is the causal agent of a number of agriculturally important diseases. It is a single-stranded, circular and unencapsidated RNA molecule with only 356-360 nucleotides and no coding capacity. Because of its peculiar structural features, it is very stable ex vivo and it is easily transmitted mechanically by contaminated hands, tools, machinery, etc. In this work, we describe the development and optimization of a method for concentrating PSTVd using Convective Interaction Media (CIM) monolithic columns. The ion-exchange chromatography on diethylamine (DEAE) monolithic analytical column (CIMac DEAE-0.1 mL) resulted in up to 30% PSTVd recovery whilst the hydrophobic interaction chromatography on C4 monolithic analytical column (CIMac C4-0.1 mL) improved it up to 60%. This was due to the fact that the binding of the viroid to the C4 matrix was less strong than to the highly charged anion-exchange matrix and could be easier and more completely eluted under the applied chromatographic conditions. Based on these preliminary results, a C4 HLD-1 (High Ligand Density) 1 mL monolithic tube column was selected for further experiments. One-litre-water samples were mixed with different viroid quantities and loaded onto the column. By using reverse transcription quantitative polymerase chain reaction (RT-qPCR), the viroid RNA was quantified in the elution fraction (≈5 mL) indicating that 70% of the viroid was recovered and concentrated by at least two orders of magnitude. This approach will be helpful in screening irrigation waters and/or hydroponic systems' nutrient solutions for the presence of even extremely low concentrations of PSTVd. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. NY-ESO-1 TCR single edited stem and central memory T cells to treat multiple myeloma without graft-versus-host disease.

    Science.gov (United States)

    Mastaglio, Sara; Genovese, Pietro; Magnani, Zulma; Ruggiero, Eliana; Landoni, Elisa; Camisa, Barbara; Schiroli, Giulia; Provasi, Elena; Lombardo, Angelo; Reik, Andreas; Cieri, Nicoletta; Rocchi, Martina; Oliveira, Giacomo; Escobar, Giulia; Casucci, Monica; Gentner, Bernhard; Spinelli, Antonello; Mondino, Anna; Bondanza, Attilio; Vago, Luca; Ponzoni, Maurilio; Ciceri, Fabio; Holmes, Michael C; Naldini, Luigi; Bonini, Chiara

    2017-08-03

    Transfer of T-cell receptors (TCRs) specific for tumor-associated antigens is a promising approach for cancer immunotherapy. We developed the TCR gene editing technology that is based on the knockout of the endogenous TCR α and β genes, followed by the introduction of tumor-specific TCR genes, and that proved safer and more effective than conventional TCR gene transfer. Although successful, complete editing requires extensive cell manipulation and 4 transduction procedures. Here we propose a novel and clinically feasible TCR "single editing" (SE) approach, based on the disruption of the endogenous TCR α chain only, followed by the transfer of genes encoding for a tumor-specific TCR. We validated SE with the clinical grade HLA-A2 restricted NY-ESO-1 157-165 -specific TCR. SE allowed the rapid production of high numbers of tumor-specific T cells, with optimal TCR expression and preferential stem memory and central memory phenotype. Similarly to unedited T cells redirected by TCR gene transfer (TCR transferred [TR]), SE T cells efficiently killed NY-ESO-1 pos targets; however, although TR cells proved highly alloreactive, SE cells showed a favorable safety profile. Accordingly, when infused in NSG mice previously engrafted with myeloma, SE cells mediated tumor rejection without inducing xenogeneic graft-versus-host disease, thus resulting in significantly higher survival than that observed in mice treated with TR cells. Overall, single TCR gene editing represents a clinically feasible approach that is able to increase the safety and efficacy of cancer adoptive immunotherapy. © 2017 by The American Society of Hematology.

  18. Monolithic integration of dual optical elements on high power semiconductor lasers

    Science.gov (United States)

    Vaissie, Laurent

    This dissertation investigates the monolithic integration of dual optical elements on high power semiconductor lasers for emission around 980nm wavelength. In the proposed configuration, light is coupled out of the AlGaAs/GaAs waveguide by a low reflectivity grating coupler towards the substrate where a second monolithic optical element is integrated to improve the device performance or functionality. A fabrication process based on electron beam lithography and plasma etching was developed to control the grating coupler duty cycle and shape. The near-field intensity profile outcoupled by the grating is modeled using a combination of finite-difference time domain (FDTD) analysis of the nonuniform grating and a self-consistent model of the broad area active region. Improvement of the near-field intensity profile in good agreement with the FDTD model is demonstrated by varying the duty cycle from 20% to 55% and including the aspect ratio dependent etching (ARDE) for sub-micron features. The grating diffraction efficiency is estimated to be higher than 95% using a detailed analysis of the losses mechanisms of the device. The grating reflectivity is estimated to be as low as 2.10-4. The low reflectivity of the light extraction process is shown to increase the device efficiency and efficiently suppress lasing oscillations if both cleaved facets are replaced by grating couplers to produce 1.5W QCW with 11 nm bandwidth into a single spot a few mm above the device. Peak power in excess of 30W without visible COMD is achieved in this case. Having optimized, the light extraction process, we demonstrate the integration of three different optical functions on the substrate of the surface-emitting laser. First, a 40 level refractive microlens milled using focused ion beam shows a twofold reduction of the full-width half maximum 1mm above the device, showing potential for monolithic integration of coupling optics on the wafer. We then show that differential quantum efficiency of

  19. Purification of papain using reactive green 5 attached supermacroporous monolithic cryogel.

    Science.gov (United States)

    Uygun, Deniz Aktaş; Akduman, Begüm; Uygun, Murat; Akgöl, Sinan; Denizli, Adil

    2012-06-01

    Supermacroporous poly(2-hydroxyethyl methacrylate) [poly(HEMA)] monolithic cryogel was prepared by radical cryocopolymerization of HEMA with N,N'-methylene bisacrylamide as crosslinker. Reactive Green 5 dye was immobilized to the cryogel with nucleophilic substitution reaction, and this dye attached cryogel column was used for affinity purification of papain from Carica papaya latex. Reactive Green 5-immobilized poly(HEMA) cryogel was characterized by swelling studies, Fourier transform infrared spectroscopy, scanning electron microscopy, and energy dispersive X-ray analysis. Maximum papain adsorption capacity was found to be 68.5 mg/g polymer while nonspecific papain adsorption onto plain cryogel was negligible (3.07 mg/g polymer). Papain from C. papaya was purified 42-fold in single step with dye attached cryogel, and purity of papain was shown by silver-stained sodium dodecyl sulfate-polyacrylamide gel electrophoresis.

  20. Inlay-Retained Fixed Dental Prosthesis: A Clinical Option Using Monolithic Zirconia

    Directory of Open Access Journals (Sweden)

    Davide Augusti

    2014-01-01

    Full Text Available Different indirect restorations to replace a single missing tooth in the posterior region are available in dentistry: traditional full-coverage fixed dental prostheses (FDPs, implant-supported crowns (ISC, and inlay-retained FDPs (IRFDP. Resin bonded FDPs represent a minimally invasive procedure; preexisting fillings can minimize tooth structure removal and give retention to the IRFDP, transforming it into an ultraconservative option. New high strength zirconia ceramics, with their stiffness and high mechanical properties, could be considered a right choice for an IRFDP rehabilitation. The case report presented describes an IRFDP treatment using a CAD/CAM monolithic zirconia IRFDP; clinical and laboratory steps are illustrated, according to the most recent scientific protocols. Adhesive procedures are focused on the Y-TZP and tooth substrate conditioning methods. Nice esthetic and functional integration of indirect restoration at two-year follow-up confirmed the success of this conservative approach.

  1. Degradation of orange dyes and carbamazepine by soybean peroxidase immobilized on silica monoliths and titanium dioxide.

    Science.gov (United States)

    Calza, Paola; Zacchigna, Dario; Laurenti, Enzo

    2016-12-01

    In this paper, the removal of three common dyes (orange I, orange II, and methylorange) and of the anticonvulsant drug carbamazepine from aqueous solutions by means of enzymatic and photocatalytic treatment was studied. Soybean peroxidase (SBP) was used as biocatalyst, both free in solution and immobilized on silica monoliths, and titanium dioxide as photocatalyst. The combination of the two catalysts led to a faster (about two to four times) removal of all the orange dyes compared to the single systems. All the dyes were completely removed within 2 h, also in the presence of immobilized SBP. As for carbamazepine, photocatalytic treatment prevails on the enzymatic degradation, but the synergistic effect of two catalysts led to a more efficient degradation; carbamazepine's complete disappearance was achieved within 60 min with combined system, while up to 2 h is required with TiO 2 only.

  2. Performance of a SiPM based semi-monolithic scintillator PET detector

    Science.gov (United States)

    Zhang, Xianming; Wang, Xiaohui; Ren, Ning; Kuang, Zhonghua; Deng, Xinhan; Fu, Xin; Wu, San; Sang, Ziru; Hu, Zhanli; Liang, Dong; Liu, Xin; Zheng, Hairong; Yang, Yongfeng

    2017-10-01

    A depth encoding PET detector module using semi-monolithic scintillation crystal single-ended readout by a SiPM array was built and its performance was measured. The semi-monolithic scintillator detector consists of 11 polished LYSO slices measuring 1  ×  11.6  ×  10 mm3. The slices are glued together with enhanced specular reflector (ESR) in between and outside of the slices. The bottom surface of the slices is coupled to a 4  ×  4 SiPM array with a 1 mm light guide and silicon grease between them. No reflector is used on the top surface and two sides of the slices to reduce the scintillation photon reflection. The signals of the 4  ×  4 SiPM array are grouped along rows and columns separately into eight signals. Four SiPM column signals are used to identify the slices according to the center of the gravity of the scintillation photon distribution in the pixelated direction. Four SiPM row signals are used to estimate the y (monolithic direction) and z (depth of interaction) positions according to the center of the gravity and the width of the scintillation photon distribution in the monolithic direction, respectively. The detector was measured with 1 mm sampling interval in both the y and z directions with electronic collimation by using a 0.25 mm diameter 22Na point source and a 1  ×  1  ×  20 mm3 LYSO crystal detector. An average slice based energy resolution of 14.9% was obtained. All slices of 1 mm thick were clearly resolved and a detector with even thinner slices could be used. The y positions calculated with the center of gravity method are different for interactions happening at the same y, but different z positions due to depth dependent edge effects. The least-square minimization and the maximum likelihood positioning algorithms were developed and both methods improved the spatial resolution at the edges of the detector as compared with the center of gravity method. A mean absolute error

  3. Monolithic millimeter-wave and picosecond electronic technologies

    International Nuclear Information System (INIS)

    Talley, W.K.; Luhmann, N.C.

    1996-01-01

    Theoretical and experimental studies into monolithic millimeter-wave and picosecond electronic technologies have been undertaken as a collaborative project between the Lawrence Livermore National Laboratory (LLNL) and the University of California Department of Applied Science Coherent Millimeter-Wave Group under the auspices of the Laboratory Directed Research and Development Program at LLNL. The work involves the design and fabrication of monolithic frequency multiplier, beam control, and imaging arrays for millimeter-wave imaging and radar, as well as the development of high speed nonlinear transmission lines for ultra-wideband radar imaging, time domain materials characterization and magnetic fusion plasma applications. In addition, the Coherent Millimeter-Wave Group is involved in the fabrication of a state-of-the-art X-band (∼8-11 GHz) RF photoinjector source aimed at producing psec high brightness electron bunches for advanced accelerator and coherent radiation generation studies

  4. Hydrogenation with monolith reactor under conditions of immiscible liquid phases

    Science.gov (United States)

    Nordquist, Andrew Francis; Wilhelm, Frederick Carl; Waller, Francis Joseph; Machado, Reinaldo Mario

    2002-01-01

    The present invention relates to an improved for the hydrogenation of an immiscible mixture of an organic reactant in water. The immiscible mixture can result from the generation of water by the hydrogenation reaction itself or, by the addition of, water to the reactant prior to contact with the catalyst. The improvement resides in effecting the hydrogenation reaction in a monolith catalytic reactor from 100 to 800 cpi, at a superficial velocity of from 0.1 to 2 m/second in the absence of a cosolvent for the immiscible mixture. In a preferred embodiment, the hydrogenation is carried out using a monolith support which has a polymer network/carbon coating onto which a transition metal is deposited.

  5. Monolithic integration of a plasmonic sensor with CMOS technology

    Science.gov (United States)

    Shakoor, Abdul; Cheah, Boon C.; Hao, Danni; Al-Rawhani, Mohammed; Nagy, Bence; Grant, James; Dale, Carl; Keegan, Neil; McNeil, Calum; Cumming, David R. S.

    2017-02-01

    Monolithic integration of nanophotonic sensors with CMOS detectors can transform the laboratory based nanophotonic sensors into practical devices with a range of applications in everyday life. In this work, by monolithically integrating an array of gold nanodiscs with the CMOS photodiode we have developed a compact and miniaturized nanophotonic sensor system having direct electrical read out. Doing so eliminates the need of expensive and bulky laboratory based optical spectrum analyzers used currently for measurements of nanophotonic sensor chips. The experimental optical sensitivity of the gold nanodiscs is measured to be 275 nm/RIU which translates to an electrical sensitivity of 5.4 V/RIU. This integration of nanophotonic sensors with the CMOS electronics has the potential to revolutionize personalized medical diagnostics similar to the way in which the CMOS technology has revolutionized the electronics industry.

  6. From 1D to 3D - macroscopic nanowire aerogel monoliths

    Science.gov (United States)

    Cheng, Wei; Rechberger, Felix; Niederberger, Markus

    2016-07-01

    Here we present a strategy to assemble one-dimensional nanostructures into a three-dimensional architecture with macroscopic size. With the assistance of centrifugation, we successfully gel ultrathin W18O49 nanowires with diameters of 1 to 2 nm and aspect ratios larger than 100 into 3D networks, which are transformed into monolithic aerogels by supercritical drying.Here we present a strategy to assemble one-dimensional nanostructures into a three-dimensional architecture with macroscopic size. With the assistance of centrifugation, we successfully gel ultrathin W18O49 nanowires with diameters of 1 to 2 nm and aspect ratios larger than 100 into 3D networks, which are transformed into monolithic aerogels by supercritical drying. Electronic supplementary information (ESI) available: Experimental details, SEM and TEM images, and digital photographs. See DOI: 10.1039/c6nr04429h

  7. Coherent optical monolithic phased-array antenna steering system

    Science.gov (United States)

    Hietala, Vincent M.; Kravitz, Stanley H.; Vawter, Gregory A.

    1994-01-01

    An optical-based RF beam steering system for phased-array antennas comprising a photonic integrated circuit (PIC). The system is based on optical heterodyning employed to produce microwave phase shifting by a monolithic PIC constructed entirely of passive components. Microwave power and control signal distribution to the antenna is accomplished by optical fiber, permitting physical separation of the PIC and its control functions from the antenna. The system reduces size, weight, complexity, and cost of phased-array antenna systems.

  8. Monolithic AlGaAs second-harmonic nanoantennas.

    Science.gov (United States)

    Gili, V F; Carletti, L; Locatelli, A; Rocco, D; Finazzi, M; Ghirardini, L; Favero, I; Gomez, C; Lemaître, A; Celebrano, M; De Angelis, C; Leo, G

    2016-07-11

    We demonstrate monolithic aluminum gallium arsenide (AlGaAs) optical nanoantennas. Using a selective oxidation technique, we fabricated epitaxial semiconductor nanocylinders on an aluminum oxide substrate. Second harmonic generation from AlGaAs nanocylinders of 400 nm height and varying radius pumped with femtosecond pulses delivered at 1554-nm wavelength has been measured, revealing a peak conversion efficiency exceeding 10-5 for nanocylinders with an optimized geometry.

  9. Clinical assessment of enamel wear caused by monolithic zirconia crowns.

    Science.gov (United States)

    Stober, T; Bermejo, J L; Schwindling, F S; Schmitter, M

    2016-08-01

    The purpose of this study was to measure enamel wear caused by antagonistic monolithic zirconia crowns and to compare this with enamel wear caused by contralateral natural antagonists. Twenty monolithic zirconia full molar crowns were placed in 20 patients. Patients with high activity of the masseter muscle at night (bruxism) were excluded. For analysis of wear, vinylpolysiloxane impressions were prepared after crown incorporation and at 6-, 12-, and 24-month follow-up. Wear of the occlusal contact areas of the crowns, of their natural antagonists, and of two contralateral natural antagonists (control teeth) was measured by use of plaster replicas and a 3D laser-scanning device. Differences of wear between the zirconia crown antagonists and the control teeth were investigated by means of two-sided paired Student's t-tests and linear regression analysis. After 2 years, mean vertical loss was 46 μm for enamel opposed to zirconia, 19-26 μm for contralateral control teeth and 14 μm for zirconia crowns. Maximum vertical loss was 151 μm for enamel opposed to zirconia, 75-115 μm for control teeth and 60 μm for zirconia crowns. Statistical analysis revealed significant differences between wear of enamel by zirconia-opposed teeth and by control teeth. Gender, which significantly affected wear, was identified as a possible confounder. Monolithic zirconia crowns generated more wear of opposed enamel than did natural teeth. Because of the greater wear caused by other dental ceramics, the use of monolithic zirconia crowns may be justified. © 2016 John Wiley & Sons Ltd.

  10. An Energy Preserving Monolithic Eulerian Fluid-Structure Numerical Scheme *

    OpenAIRE

    Pironneau, Olivier

    2016-01-01

    The conservation laws of continuum mechanic written in an Eulerian frame make no difference between fluids and solids except in the expression of the stress tensors, usually with Newton's hypothesis for the fluids and Helmholtz potentials of energy for hyperelastic solids. By taking the velocities as unknown , monolithic methods for fluid structure interactions (FSI) are built. In this article such a formulation is analyzed when the fluid is compressible and the fluid is incompressible. The i...

  11. An Energy stable Monolithic Eulerian Fluid-Structure Numerical Scheme *

    OpenAIRE

    Pironneau , Olivier

    2017-01-01

    The conservation laws of continuum mechanic written in an Eulerian frame make no difference between fluids and solids except in the expression of the stress tensors, usually with Newton's hypothesis for the fluids and Helmholtz potentials of energy for hyperelastic solids. By taking the velocities as unknown , monolithic methods for fluid structure interactions (FSI) are built. In this article such a formulation is analyzed when the fluid is compressible and the fluid is incompressible. The i...

  12. Fabrication and characterization of nanotemplated carbon monolithic material

    OpenAIRE

    He, Xiaoyun; Nesterenko, Ekaterina; Nesterenko, Pavel; Brabazon, Dermot; Zhou, Lin; Glennon, Jeremy D.; Luong, John H.T.; Paull, Brett

    2013-01-01

    A novel hierarchical nanotemplated carbon monolithic rod (NTCM) was prepared using a novel facile nanotemplating approach. The NTCM was obtained using C60-fullerene modified silica gels as hard templates, which were embedded in a phenolic resin containing a metal catalyst for localized graphitization, followed by bulk carbonization, and template and catalyst removal. TEM, SEM, and BET measurements revealed that NTCM possessed an integrated open hierarchical porous structure, with a trimodal p...

  13. Porous polyacrylamide monoliths in hydrophilic interaction capillary electrochromatography of oligosaccharides

    Czech Academy of Sciences Publication Activity Database

    Guryča, Vilém; Mechref, Y.; Palm, A. K.; Michálek, Jiří; Pacáková, V.; Novotny, M. V.

    2007-01-01

    Roč. 70, č. 1 (2007), s. 3-13 ISSN 0165-022X R&D Projects: GA MŠk 1M0538 Grant - others:U.S. Department of Health and Human Services(US) GM24349 Institutional research plan: CEZ:AV0Z40500505 Keywords : polyacrylamide monoliths * analytical glycobiology * capillary electrochromatography Subject RIV: CD - Macromolecular Chemistry Impact factor: 1.338, year: 2007

  14. Nanoparticle-modified monolithic pipette tips for phosphopeptide enrichment

    Czech Academy of Sciences Publication Activity Database

    Křenková, Jana; Foret, František

    2013-01-01

    Roč. 405, č. 7 (2013), s. 2175-2183 ISSN 1618-2642 R&D Projects: GA ČR(CZ) GAP301/11/2055 Grant - others:Jihomoravský kraj(CZ) 2SGA2721 Program:2SGA Institutional support: RVO:68081715 Keywords : nanoparticles * monolith * phosphopeptide Enrichment Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 3.578, year: 2013

  15. Distributed or Monolithic? A Computational Architecture Decision Framework

    OpenAIRE

    Mosleh, Mohsen; Dalili, Kia; Heydari, Babak

    2016-01-01

    Distributed architectures have become ubiquitous in many complex technical and socio-technical systems because of their role in improving uncertainty management, accommodating multiple stakeholders, and increasing scalability and evolvability. This departure from monolithic architectures provides a system with more flexibility and robustness in response to uncertainties that it may confront during its lifetime. Distributed architecture does not provide benefits only, as it can increase cost a...

  16. Short monolithic columns for purification and fractionation of peptide samples

    Czech Academy of Sciences Publication Activity Database

    Moravcová, Dana; Kahle, Vladislav; Řehulková, Helena; Chmelík, Jan; Řehulka, Pavel

    2009-01-01

    Roč. 1216, č. 17 (2009), s. 3629-3636 ISSN 0021-9673 R&D Projects: GA MŠk LC06023; GA MŠk 1M06030; GA ČR GA203/06/1179; GA AV ČR IAAX00310701 Institutional research plan: CEZ:AV0Z40310501 Keywords : proteomics * monolithic capillary columns * sample pre-treatment Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 4.101, year: 2009

  17. Monolithic GaAs surface acoustic wave chemical microsensor array

    Energy Technology Data Exchange (ETDEWEB)

    HIETALA,VINCENT M.; CASALNUOVO,STEPHEN A.; HELLER,EDWIN J.; WENDT,JOEL R.; FRYE-MASON,GREGORY CHARLES; BACA,ALBERT G.

    2000-03-09

    A four-channel surface acoustic wave (SAW) chemical sensor array with associated RF electronics is monolithically integrated onto one GaAs IC. The sensor operates at 690 MHz from an on-chip SAW based oscillator and provides simple DC voltage outputs by using integrated phase detectors. This sensor array represents a significant advance in microsensor technology offering miniaturization, increased chemical selectivity, simplified system assembly, improved sensitivity, and inherent temperature compensation.

  18. Extended Leach Testing of Simulated LAW Cast Stone Monoliths

    Energy Technology Data Exchange (ETDEWEB)

    Serne, R. Jeffrey [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Lanigan, David C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Westsik, Joseph H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Williams, Benjamin D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Jung, H. B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wang, Guohui [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-08-12

    This revision to the original report adds two longer term leach sets of data to the report and provides more discussion and graphics on how to interpret the results from long-term laboratory leach tests. The leach tests were performed at Pacific Northwest National Laboratory (PNNL) for Washington River Protection Solutions (WRPS) to evaluate the release of key constituents from monoliths of Cast Stone prepared with four simulated low-activity waste (LAW) liquid waste streams.

  19. Preparation and evaluation of zirconia-coated silica monolith for capillary electrochromatography.

    Science.gov (United States)

    Shi, Z-G; Feng, Y-Q; Xu, L; Zhang, M; Da, S-L

    2004-06-17

    Silica monoliths were fabricated inside fused-silica capillaries. Then the monolithic columns were coated with membrane-like zirconia. The zirconia-coated silica monoliths exhibited different EOF behavior comparing with that of bare silica monoliths. The magnitude and direction could be manipulated by changing the running buffers. Due to the amphoteric characteristic of zirconia, the silica monoliths with zirconia surface facilitate the separation of basic compounds. Aromatic amines and alkaloids were separated without obvious peak tailing. The zirconia surface was easily modified with octadecylphosphonic acid for the separation of neutral compounds. Column efficiency as high as 90,000 and 80,000m(-1) was obtained for beberine and naphthalene, respectively. Furthermore, the zirconia coating increased the stability of the monolithic columns. Even after being exposed to severe condition, there was no apparently efficiency decrease for the test samples.

  20. Cholesterol-imprinted macroporous monoliths: Preparation and characterization.

    Science.gov (United States)

    Stepanova, Mariia А; Kinziabulatova, Lilia R; Nikitina, Anna A; Korzhikova-Vlakh, Evgenia G; Tennikova, Tatiana B

    2017-11-01

    The development of sorbents for selective binding of cholesterol, which is a risk factor for cardiovascular disease, has a great importance for analytical science and medicine. In this work, two series of macroporous cholesterol-imprinted monolithic sorbents differing in the composition of functional monomers (methacrylic acid, butyl methacrylate, 2-hydroxyethyl methacrylate and ethylene dimethacrylate), amount of a template (4, 6 and 8 mol%) used for molecular imprinting, as well as mean pore size were synthesized by in situ free-radical process in stainless steel housing of 50 mm × 4.6 mm i.d. All prepared materials were characterized regarding to their hydrodynamic permeability and porous properties, as well as examined by BET and SEM methods. Imprinting factors, apparent dynamic dissociation constants, the maximum binding capacity, the number of theoretical plates and the height equivalent to a theoretical palate of MIP monoliths at different mobile phase flow rates were determined. The separation of a mixture of structural analogues, namely, cholesterol and prednisolone, was demonstrated. Additionally, the possibility of using the developed monoliths for cholesterol solid-phase extraction from simulated biological solution was shown. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Effect of cements on fracture resistance of monolithic zirconia crowns

    Science.gov (United States)

    Nakamura, Keisuke; Mouhat, Mathieu; Nergård, John Magnus; Lægreid, Solveig Jenssen; Kanno, Taro; Milleding, Percy; Örtengren, Ulf

    2016-01-01

    Abstract Objectives The present study investigated the effect of cements on fracture resistance of monolithic zirconia crowns in relation to their compressive strength. Materials and methods Four different cements were tested: zinc phosphate cement (ZPC), glass-ionomer cement (GIC), self-adhesive resin-based cement (SRC) and resin-based cement (RC). RC was used in both dual cure mode (RC-D) and chemical cure mode (RC-C). First, the compressive strength of each cement was tested according to a standard (ISO 9917-1:2004). Second, load-to-failure test was performed to analyze the crown fracture resistance. CAD/CAM-produced monolithic zirconia crowns with a minimal thickness of 0.5 mm were prepared and cemented to dies with each cement. The crown–die samples were loaded until fracture. Results The compressive strength of SRC, RC-D and RC-C was significantly higher than those of ZPC and GIC (p crown between the groups. Conclusion The values achieved in the load-to-failure test suggest that monolithic zirconia crowns with a minimal thickness of 0.5 mm may have good resistance against fracture regardless of types of cements. PMID:27335900

  2. A Ferrite LTCC-Based Monolithic SIW Phased Antenna Array

    KAUST Repository

    Nafe, Ahmed

    2016-11-17

    In this work, we present a novel configuration for realizing monolithic SIW-based phased antenna arrays using Ferrite LTCC technology. Unlike the current common schemes for realizing SIW phased arrays that rely on surface-mount component (p-i-n diodes, etc) for controlling the phase of the individual antenna elements, here the phase is tuned by biasing of the ferrite filling of the SIW. This approach eliminates the need for mounting of any additional RF components and enables seamless monolithic integration of phase shifters and antennas in SIW technology. As a proof of concept, a two-element slotted SIW-based phased array is designed, fabricated and measured. The prototype exhibits a gain of 4.9 dBi at 13.2 GHz and a maximum E-plane beam-scanning of 28 degrees using external windings for biasing the phase shifters. Moreover, the array can achieve a maximum beam-scanning of 19 degrees when biased with small windings that are embedded in the package. This demonstration marks the first time a fully monolithic SIW-based phased array is realized in Ferrite LTCC technology and paves the way for future larger-size implementations.

  3. Photoinitiated grafting of porous polymer monoliths and thermoplastic polymers for microfluidic devices

    Science.gov (United States)

    Frechet, Jean M. J. [Oakland, CA; Svec, Frantisek [Alameda, CA; Rohr, Thomas [Leiden, NL

    2008-10-07

    A microfluidic device preferably made of a thermoplastic polymer that includes a channel or a multiplicity of channels whose surfaces are modified by photografting. The device further includes a porous polymer monolith prepared via UV initiated polymerization within the channel, and functionalization of the pore surface of the monolith using photografting. Processes for making such surface modifications of thermoplastic polymers and porous polymer monoliths are set forth.

  4. Application of Monolithic Zirconia Ceramics in Dental Practice: A Case History Report.

    Science.gov (United States)

    Kim, Hee-Kyung; Kim, Sung-Hun; Lee, Jai-Bong; Han, Jung-Suk; Yeo, In-Sung

    2016-01-01

    Monolithic zirconia restorations increasingly have been used in dental practice in recent years and demonstrate superior mechanical performance compared with porcelain-veneered zirconia restorations. Recent advances in manufacturing technology have made possible the fabrication of translucent monolithic zirconia ceramics. This case report describes three clinical examples of monolithic zirconia fixed dental prostheses being used in the anterior and posterior regions and exhibiting acceptable esthetic results.

  5. Central Solenoid

    CERN Multimedia

    2002-01-01

    The Central Solenoid (CS) is a single layer coil wound internally in a supporting cylinder housed in the cryostat of the Liquid Argon Calorimeter. It was successfully tested at Toshiba in December 2000 and was delivered to CERN in September 2001 ready for integration in the LAr Calorimeter in 2003. An intermediate test of the chimney and proximity cryogenics was successfully performed in June 2002.

  6. Electrochromatographic performance of conventional and polar-embedded C16 silica monolithic stationary phases.

    Science.gov (United States)

    Ye, Fanggui; Huang, Baojun; Wang, Shun; Zhao, Shulin

    2010-11-01

    A novel monolithic silica column that has a polar-embedded amide-secondary amine group linking with C16 functionality for RP-CEC is described. The amide-secondary aminealkyloxysilane was synthesized by the reaction of 3-(2-aminoethylamino) propyltrimethoxysilane with hexadecanoyl chloride. Then, the silylant agent was bonded to the silica monolith matrix to produce hexadecanamide-secondary amine bonded silica (HDAIS) monolithic column. The electrochromatographic performance of HDAIS monolithic column for the separation of neutral, basic and polar solutes was studied, which was compared to that using the hexadecyl bonded silica monolithic column. The HDAIS monolithic column displayed reduced hydrophobic retention characteristics in the separation of five hydrophobic n-alkylbenzenes and four polar phenols when compared to the hexadecyl bonded silica monolithic column. A very much reduced silanol activity of HDAIS monolithic column was observed in the separation of test basic mixture including four aromatic amines, atenolol and metoprolol with 10 mM borate buffer (pH 7.5) containing 30% v/v ACN as the mobile phase. The comparison results indicate good performance for both polar and basic mixtures on HDAIS monolithic column in RP-CEC, and also show promising results for further applications.

  7. [Recent developments in preparation of monolithic columns and their applications in proteomic analysis].

    Science.gov (United States)

    Zou, Hanfa; Wu, Minghuo; Wang, Fangjun; Wu, Renan; Ye, Mingliang

    2009-09-01

    Monolithic column is a continuous unitary porous structure prepared by in-situ polymerization or consolidation inside the column tubing. Monolithic columns have been attracted great attention due to their simple preparation procedure, high permeability and high mass transfer rate. Big progress on the technology and methods for the preparation of monolithic columns and their applications to the highly efficient separation and pretreatment of biological samples have been made in last decade. This review summarizes the developments in the preparation of the monolithic columns and their applications to the proteomic analysis during the last five years.

  8. Development of the trigger algorithm for the MONOLITH experiment

    International Nuclear Information System (INIS)

    Gutsche, O.

    2001-05-01

    The MONOLITH project is proposed to prove atmospheric neutrino oscillations and to improve the corresponding measurements of Super-Kamiokande. The MONOLITH detector consists of a massive (34 kt) magnetized iron tracking calorimeter and is optimized for muon neutrino detection. This diploma thesis presents the development of the trigger algorithm for the MONOLITH experiment and related test measurements. Chapter two gives an introduction to the mechanism of neutrino oscillations. The two flavor approximation and the three flavor mechanism are described and influences of matter on neutrino oscillations are discussed. The principles of neutrino oscillation experiments are discussed and the results of Super-Kamiokande, a neutrino oscillation experiment, are presented. Super-Kamiokande gave the strongest indications for atmospheric neutrino oscillations so far. The third chapter introduces the MONOLITH project in the context of atmospheric neutrino oscillations. The MONOLITH detector is described and the main active component, the glass spark chamber, is presented. Chapter four presents the practical part of this thesis. A test setup of a glass spark chamber is built up including a cosmics trigger and a data acquisition system. Cosmic ray muons are used for the investigation of the chamber. During a long term test, the stability of the efficiency and the noise rate of the chamber are investigated. A status report of the results is given. The results are taken as input for the trigger development. In chapter five, the development of the trigger algorithm is presented. In the beginning, the structural design of the trigger algorithm is described. The efficiency and the rate of the trigger algorithm are investigated using two event sources, a Monte Carlo neutrino event sample and a generated noise sample. For the analysis, the data sources are processed by several processing stages which are visualized by corresponding event displays. In the course of the data processing

  9. DATA QUALITY OBJECTIVE SUMMARY REPORT FOR THE 105 K EAST ION EXCHANGE COLUMN MONOLITH

    Energy Technology Data Exchange (ETDEWEB)

    JOCHEN, R.M.

    2007-08-02

    The 105-K East (KE) Basin Ion Exchange Column (IXC) cells, lead caves, and the surrounding vault are to be removed as necessary components in implementing ''Hanford Federal Facility Agreement and Consent Order'' (Ecology et al. 2003) milestone M-034-32 (Complete Removal of the K East Basin Structure). The IXCs consist of six units located in the KE Basin, three in operating positions in cells and three stored in a lead cave. Methods to remove the IXCs from the KE Basin were evaluated in KBC-28343, ''Disposal of K East Basin Ion Exchange Column Evaluation''. The method selected for removal was grouting the six IXCs into a single monolith for disposal at the Environmental Restoration Disposal Facility (ERDF). Grout will be added to the IXC cells, IXC lead caves containing spent IXCs, and in the spaces between the lead cave walls and metal skin, to immobilize the contaminants, provide self-shielding, minimize void space, and provide a structurally stable waste form. The waste to be offered for disposal is the encapsulated monolith defined by the exterior surfaces of the vault and the lower surface of the underlying slab. This document presents summary of the data quality objective (DQO) process establishing the decisions and data required to support decision-making activities for the disposition of the IXC monolith. The DQO process is completed in accordance with the seven-step planning process described in EPA QA/G-4, ''Guidance for the Data Quality Objectives Process'', which is used to clarify and study objectives; define the appropriate type, quantity, and quality of data; and support defensible decision-making. The DQO process involves the following steps: (1) state the problem; (2) identify the decision; (3) identify the inputs to the decision; (4) define the boundaries of the study; (5) develop a decision rule (DR); (6) specify tolerable limits on decision errors; and (7) optimize the design for

  10. Correlation between single nucleotide polymorphism of rs3811047 in IL-1 F7 gene and rheumatoid arthritis susceptibility among Han population in central plains of China.

    Science.gov (United States)

    Shi, Li-Pu; He, Ya; Liu, Zhi-Dui

    2013-01-01

    To discuss the association between single nucleotide polymorphism (SNP) of rs3811047 in IL-1 F7 gene and rheumatoid arthritis (RA) susceptibility among the Han population in central plains of China. A total of 276 RA patients admitted to our hospital from December 2009 to December 2011 together with 276 healthy physical examinees in the same period were chosen as the subjects. The typing for rs3811047 SNP in IL-1 F7 gene was carried out by using ligase detection reaction and polymerase chain reaction technique. And the frequency of each allele and genotypes distribution was calculated so as to evaluate the association between genotype distribution and RA susceptibility. The frequency of A allele of rs3811047 in IL-1 F7 gene in RA group and control group was 16.27% and 17.68%, respectively, and that of G allele in two groups was 83.73% and 82.32%, respectively. The difference between two groups wasn't statistical significant (P >0.05). The frequency of genotype AA, AG and GG in RA group was 2.19%, 27.84% and 69.97%, respectively, while that in control group was 2.94%, 29.78% and 67.28%, respectively. The difference of distribution of three genotypes was not statistically significant (P >0.05). RA patients with A allele were better than those without A allele in joint swelling index, rest pain, HAQ scoring and blood sedimentation. There was significant difference between two groups in above indexes (PF7 gene is observed. However, A allele of rs3811047 has certain influence on the condition of RA patients. Copyright © 2013 Hainan Medical College. Published by Elsevier B.V. All rights reserved.

  11. A single institutional retrospective evaluation for younger patients with primary central nervous lymphomas on a modified R-MPV regimen followed by radiotherapy and high dose cytarabine.

    Science.gov (United States)

    Hattori, Keiichiro; Sakata-Yanagimoto, Mamiko; Okoshi, Yasushi; Kato, Takayasu; Kurita, Naoki; Yokoyama, Yasuhisa; Obara, Naoshi; Takano, Shingo; Ishikawa, Eiichi; Yamamoto, Tetsuya; Matsumura, Akira; Hasegawa, Yuichi; Chiba, Shigeru

    2017-10-12

    We conducted a retrospective analysis of patients younger than 60 years (N = 10, median age 54.5) with newly diagnosed primary central nervous system lymphoma (PCNSL) at the University of Tsukuba Hospital from January 2008 to November 2016. All the patients were scheduled to receive a single regimen without registration to any clinical trials. This was based on a phase 2 study by Memorial Sloan-Kettering Cancer Center (MSKCC); induction chemotherapy with rituximab, methotrexate, procarbazine, and vincristine (R-MPV) (five to seven cycles), followed by whole-brain radiotherapy (rd-WBRT) (23.4 Gy) and two high-dose cytarabine (HD-AC) cycles as a consolidation. The median age was 54.5 years, and median follow up duration was 33.1 months. The 3-year overall survival (OS) and progression-free survival (PFS) were 69% (95% CI 31-89%) and 56% (95% CI 20-81%). The median OS and PFS were not reached, respectively. Acute and delayed toxicities were manageable. In particular, OS and PFS of seven patients who achieved CR by the R-MPV induction chemotherapy were significantly superb (3-year OS, 100%; 3-year PFS, 80%), implying that a large proportion of patients in CR after the completion of this treatment may achieve durable disease control. On the other hand, all of the three patients who had progressive disease during this treatment died of disease progression within 1 year after diagnosis without achieving CR. Identifying the patients having a risk of failure in the R-MPV induction chemotherapy is important, and may allow us to consider a potentially more effective regimen.

  12. Simultaneous Replacement of Maxillary Central Incisors with CEREC Biogeneric Reference Technique: A Case Report

    Directory of Open Access Journals (Sweden)

    Gokhan Akgungor

    2013-06-01

    Full Text Available Biogeneric Reference Technique (BRT of the CEREC 3D v.3.8 software is an effective technique for single anterior ceramic crowns because it provides computer-controlled match of the tooth form to the contralateral tooth. BRT also enables the fabrication of two or more anterior all-ceramic crowns simultaneously. This clinical report demonstrates the clinical application of BRT for designing and milling two central incisors in one appointment using a single optical impression. After completing the virtual design of the first central incisor, it was copied and a mirror image was created. The second central incisor was designed using this replicated image and therefore a computer-controlled symmetry was obtained. The crowns were milled from monolithic feldspathic ceramic blocks and adhesively luted with dual-cured resin cement following dentin conditioning. At the two-year follow-up appointment, the restorations were intact, no adverse effects were noted, and the resultant appearance was highly satisfactory for the patient. A step-by-step protocol is described from design to cementation of these restorations.

  13. Fracture rate of monolithic zirconia restorations up to 5 years: A dental laboratory survey.

    Science.gov (United States)

    Sulaiman, Taiseer A; Abdulmajeed, Aous A; Donovan, Terence E; Cooper, Lyndon F; Walter, Ricardo

    2016-09-01

    The demand for ceramic restorations has increased over the past years because of their esthetic properties and the high cost of noble metals. However, the lack of long-term clinical studies and the difficulty of interpreting in vitro studies have placed the durability of ceramic restorations in doubt. The purpose of this study was to determine the failure rate of monolithic zirconia restorations due to fracture up to 5 years of clinical performance. Data were collected over 5 years from 2 commercial dental laboratories. Restorations that were returned to the laboratory for remake because of catastrophic failure (fracture) were identified and included. Restorations were categorized as anterior or posterior. Each category was further divided into complete-coverage single crowns (SCs) and multiple-unit fixed dental prostheses (FDPs). Fracture rates were compared and analyzed using a chi-square test (α=.05). A total of 39827 restoration records were reviewed and included 3731 anterior restorations (1952 SC; 1799 FDP) and 36096 posterior restorations (29808 SC; 6288 FDP). The overall fracture rate of up to 5 years for all restorations (anterior and posterior) was 1.09%. Fracture rates were 2.06% for all anterior restorations and 0.99% for all posterior restorations. Fracture rates were 0.97% for anterior SCs and 0.69% for posterior SCs, and the combined fracture rate (anterior and posterior) was 0.71%. For FDPs, 3.26% restorations fractured anteriorly and 2.42% fractured posteriorly, and the combined fracture rate (anterior and posterior) was 2.60%. Within the relative short-term evaluation of 5 years, restorations fabricated from monolithic zirconia material displayed relatively low fracture rates. Anterior restorations fractured at a slightly higher rate than posterior restorations, and FDPs fractured at a rate double that of SCs. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. A High Resolution Monolithic Crystal, DOI, MR Compatible, PET Detector. Final-Report

    International Nuclear Information System (INIS)

    Miyaoka, Robert S.

    2012-01-01

    The principle objective of this proposal is to develop a positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning capability that will achieve state of the art spatial resolution and sensitivity performance for small animal PET imaging. When arranged in a ring or box detector geometry, the proposed detector module will support 15% absolute detection efficiency. The detector will also be compatible with operation in a MR scanner to support simultaneous multi-modality imaging. The detector design will utilize a thick, monolithic crystal scintillator readout by a two-dimensional array of silicon photomultiplier (SiPM) devices using a novel sensor on the entrance surface (SES) design. Our hypothesis is that our single-ended readout SES design will provide an effective DOI positioning performance equivalent to more expensive dual-ended readout techniques and at a significantly lower cost. Our monolithic crystal design will also lead to a significantly lower cost system. It is our goal to design a detector with state of the art performance but at a price point that is affordable so the technology can be disseminated to many laboratories. A second hypothesis is that using SiPM arrays, the detector will be able to operate in a MR scanner without any degradation in performance to support simultaneous PET/MR imaging. Having a co-registered MR image will assist in radiotracer localization and may also be used for partial volume corrections to improve radiotracer uptake quantitation. The far reaching goal of this research is to develop technology for medical research that will lead to improvements in human health care.

  15. Facile solution synthesis and photoelectric properties of monolithic tin(II) sulfide nanobelt arrays.

    Science.gov (United States)

    Zhang, Xing; Yang, Long; Jiang, Yan; Yu, Bin-Bin; Zou, Yu-Gang; Fang, Ying; Hu, Jin-Song; Wan, Li-Jun

    2013-10-01

    The tremendous future energy demand and environmental concerns prompt the lasting search for new materials for low-cost and high-efficiency solar cells. SnS, as a low-cost, earth-abundant, and environmentally friendly material with proper band gap and absorption coefficient, has received attention as a potential candidate for solar absorber, but it is still under-developed due to insufficient conversion efficiency. Fabricating SnS nanostructured films for solar cell design could be effective to boost photovoltaic performance and pave the way for applications in photovoltaics. Herein, a facile surfactant-free solution-based approach has been developed to prepare monolithic SnS nanostructured films directly on tin foil substrate. The morphologies of nanostructured films could be tuned from well-defined orthorhombic SnS nanobelt arrays to nanorods, nanosheets, or nanoflakes by simply changing the ratio of used solvents. The photoelectric response and electronic transportation properties of SnS nanobelts were investigated by fabricating single-nanobelt-based nanodevices. The SnS nanobelt exhibited a fast and reliable photoresponse even at illumination intensity as weak as 0.103 mW cm(-2). The measurements on SnS FET devices also indicated that the synthesized SnS nanobelts demonstrated a hole mobility as high as 12.33 cm(2) V(-1) s(-1). These results reveal that the reported approach for preparing monolithic SnS nanostructured films could be useful to further develop SnS as an alternative material for low-cost solar cells and electronic devices. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Thermal management of quantum cascade lasers in an individually addressable monolithic array architecture

    Science.gov (United States)

    Missaggia, Leo; Wang, Christine; Connors, Michael; Saar, Brian; Sanchez-Rubio, Antonio; Creedon, Kevin; Turner, George; Herzog, William

    2016-03-01

    There are a number of military and commercial applications for high-power laser systems in the mid-to-long-infrared wavelength range. By virtue of their demonstrated watt-level performance and wavelength diversity, quantum cascade laser (QCL) and amplifier devices are an excellent choice of emitter for those applications. To realize the power levels of interest, beam combining of arrays of these emitters is required and as a result, array technology must be developed. With this in mind, packaging and thermal management strategies were developed to facilitate the demonstration of a monolithic QCL array operating under CW conditions. Thermal models were constructed and simulations performed to determine the effect of parameters such as array-element ridge width and pitch on gain region temperature rise. The results of the simulations were considered in determining an appropriate QCL array configuration. State-of-the-art micro-impingement cooling along with an electrical distribution scheme comprised of AlN multi-layer technology were integrated into the design. The design of the module allows for individual electrical addressability of the array elements, a method of phase control demonstrated previously for coherent beam combining of diode arrays, along with access to both front and rear facets. Hence, both laser and single-pass amplifier arrays can be accommodated. A module was realized containing a 5 mm cavity length monolithic QCL array comprised of 7 elements on 450 m pitch. An output power of 3.16 W was demonstrated under CW conditions at an emission wavelength of 9μm.

  17. Preparation of organic monolithic columns in polytetrafluoroethylene tubes for reversed-phase liquid chromatography

    Energy Technology Data Exchange (ETDEWEB)

    Catalá-Icardo, M., E-mail: mocaic@qim.upv.es [Research Institute for Integrated Management of Coastal Areas, Universitat Politècnica de València, Paranimf 1, 46730, Grao de Gandía, Valencia (Spain); Torres-Cartas, S.; Meseguer-Lloret, S.; Gómez-Benito, C. [Research Institute for Integrated Management of Coastal Areas, Universitat Politècnica de València, Paranimf 1, 46730, Grao de Gandía, Valencia (Spain); Carrasco-Correa, E.; Simó-Alfonso, E.F.; Ramis-Ramos, G. [Department of Analytical Chemistry, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia (Spain); Herrero-Martínez, J.M., E-mail: jmherrer@uv.es [Department of Analytical Chemistry, Universitat de València, Dr. Moliner 50, 46100, Burjassot, Valencia (Spain)

    2017-04-01

    In this work, a method for the preparation and anchoring of polymeric monoliths in a polytetrafluoroethylene (PTFE) tubing as a column housing for microbore HPLC is described. In order to assure a covalent attachment of the monolith to the inner wall of the PTFE tube, a two-step procedure was developed. Two surface etching reagents, a commercial sodium naphthalene solution (Fluoroetch{sup ®}), or mixtures of H{sub 2}O{sub 2} and H{sub 2}SO{sub 4}, were tried and compared. Then, the obtained hydroxyl groups on the PTFE surface were modified by methacryloylation. Attenuated total reflectance Fourier-transform infrared (ATR-FTIR) spectroscopy and scanning electron microscopy (SEM) confirmed the successful modification of the tubing wall and the stable anchorage of monolith to the wall, respectively. Special emphasis was also put on the reduction of the unwanted effects of shrinking of monolith during polymerization, by using an external proper mold and by selecting the adequate monomers in order to increase the flexibility of the polymer. Poly(glycidyl methacrylate-co-divinylbenzene) monoliths were in situ synthesized by thermal polymerization within the confines of surface-vinylized PTFE tubes. The modified PTFE tubing tightly held the monolith, and the monolithic column exhibited good pressure resistance up to 20 MPa. The column performance was also evaluated via the isocratic separation of a series of alkylbenzenes in the reversed-phase mode. The optimized monolithic columns gave plate heights ranged between 70 and 80 μm. The resulting monoliths were also satisfactorily applied to the separation of proteins. - Highlights: • Successful surface etching of PTFE inner wall tubing was done. • The modified PTFE support was next methacryloylated with GMA. • Organic polymeric monolith was in situ prepared in the functionalized PTFE tube. • The monolithic columns gave suitable pressure resistance and separation of proteins.

  18. Photon-counting monolithic avalanche photodiode arrays for the super collider

    International Nuclear Information System (INIS)

    Ishaque, A.N.; Castleberry, D.E.; Rougeot, H.M.

    1994-01-01

    In fiber tracking, calorimetry, and other high energy and nuclear physics experiments, the need arises to detect an optical signal consisting of a few photons (in some cases a single photoelectron) with a detector insensitive to magnetic fields. Previous attempts to detect a single photoelectron have involved avalanche photodiodes (APDs) operated in the Geiger mode, the visible light photon counter, and a photomultiplier tube with an APD as the anode. In this paper it is demonstrated that silicon APDs, biased below the breakdown voltage, can be used to detect a signal of a few photons with conventional pulse counting circuitry at room temperature. Moderate cooling, it is further argued, could make it possible to detect a single photoelectron. Monolithic arrays of silicon avalanche photodiodes fabricated by Radiation Monitoring Devices, Inc. (RMD) were evaluated for possible use in the Super Collider detector systems. Measurements on 3 element x 3 element (2 mm pitch) APD arrays, using pulse counting circuitry with a charge sensitive amplifier (CSA) and a Gaussian filter, are reported and found to conform to a simple noise model. The model is used to obtain the optimal operating point. Experimental results are described in Section II, modeling results in Section III, and the conclusions are summarized in Section IV

  19. Nanoscale photonic crystal sensor arrays on monolithic substrates using side-coupled resonant cavity arrays.

    Science.gov (United States)

    Yang, Daquan; Tian, Huiping; Ji, Yuefeng

    2011-10-10

    We present nanoscale photonic crystal sensor arrays (NPhCSAs) on monolithic substrates. The NPhCSAs can be used as an opto-fluidic architecture for performing highly parallel, label-free detection of biochemical interactions in aqueous environments. The architecture consists of arrays of lattice-shifted resonant cavities side-coupled to a single PhC waveguide. Each resonant cavity has slightly different cavity spacing and is shown to independently shift its resonant peak (a single and narrow drop) in response to the changes in refractive index. The extinction ratio of well-defined single drop exceeds 20 dB. With three-dimensional finite-difference time-domain (3D-FDTD) technique, we demonstrate that the refractive index sensitivity of 115.60 nm/RIU (refractive index unit) is achieved and a refractive index detection limit is approximately of 8.65×10-5 for this device. In addition, the sensitivity can be adjusted from 84.39 nm/RIU to 161.25 nm/RIU by changing the number of functionalized holes.

  20. Recent advances in the preparation and application of monolithic capillary columns in separation science

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Tingting; Yang, Xi; Xu, Yujing [Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009 (China); Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009 (China); Ji, Yibing, E-mail: jiyibing@msn.com [Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 210009 (China); Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, Nanjing, 210009 (China)

    2016-08-10

    Novel column technologies involving various materials and efficient reactions have been investigated for the fabrication of monolithic capillary columns in the field of analytical chemistry. In addition to the development of these miniaturized systems, a variety of microscale separation applications have achieved noteworthy results, providing a stepping stone for new types of chromatographic columns with improved efficiency and selectivity. Three novel strategies for the preparation of capillary monoliths, including ionic liquid-based approaches, nanoparticle-based approaches and “click chemistry”, are highlighted in this review. Furthermore, we present the employment of state-of-the-art capillary monolithic stationary phases for enantioseparation, solid-phase microextraction, mixed-mode separation and immobilized enzyme reactors. The review concludes with recommendations for future studies and improvements in this field of research. - Highlights: • Preparation of novel monolithic capillary columns have shown powerful potential in analytical chemistry field. • Various materials including ionic liquids and nanoparticles involved into capillary monolithic micro-devices are concluded. • Click chemistry strategy applied for preparing monolithic capillary columns is reviewed. • Recent strategies utilized in constructing different capillary monoliths for enantiomeric separation are summarized. • Advancement of capillary monoliths for complex samples analysis is comprehensively described.

  1. Monolithic junction field-effect transistor charge preamplifier for calorimetry at high luminosity hadron colliders

    International Nuclear Information System (INIS)

    Radeka, V.; Rescia, S.; Rehn, L.A.; Manfredi, P.F.; Speziali, V.

    1991-11-01

    The outstanding noise and radiation hardness characteristics of epitaxial-channel junction field-effect transistors (JFET) suggest that a monolithic preamplifier based upon them may be able to meet the strict specifications for calorimetry at high luminosity colliders. Results obtained so far with a buried layer planar technology, among them an entire monolithic charge-sensitive preamplifier, are described

  2. Monolithic Gyroidal Mesoporous Mixed Titanium–Niobium Nitrides

    Science.gov (United States)

    2015-01-01

    Mesoporous transition metal nitrides are interesting materials for energy conversion and storage applications due to their conductivity and durability. We present ordered mixed titanium–niobium (8:2, 1:1) nitrides with gyroidal network structures synthesized from triblock terpolymer structure-directed mixed oxides. The materials retain both macroscopic integrity and mesoscale ordering despite heat treatment up to 600 °C, without a rigid carbon framework as a support. Furthermore, the gyroidal lattice parameters were varied by changing polymer molar mass. This synthesis strategy may prove useful in generating a variety of monolithic ordered mesoporous mixed oxides and nitrides for electrode and catalyst materials. PMID:25122534

  3. Inherent polarization entanglement generated from a monolithic semiconductor chip

    DEFF Research Database (Denmark)

    Horn, Rolf T.; Kolenderski, Piotr; Kang, Dongpeng

    2013-01-01

    Creating miniature chip scale implementations of optical quantum information protocols is a dream for many in the quantum optics community. This is largely because of the promise of stability and scalability. Here we present a monolithically integratable chip architecture upon which is built...... a photonic device primitive called a Bragg reflection waveguide (BRW). Implemented in gallium arsenide, we show that, via the process of spontaneous parametric down conversion, the BRW is capable of directly producing polarization entangled photons without additional path difference compensation, spectral...... as a serious contender on which to build large scale implementations of optical quantum processing devices....

  4. A monolithic (Si) massively broadband non-reverberant monopole

    International Nuclear Information System (INIS)

    Vilches, Antonio; Michelakis, Kostis; Toumazou, Chris; Hand, Jeff

    2008-01-01

    A novel monolithic implementation of a Wu–King profiled antenna intended for use in critical time-domain/UWB/imaging applications is presented. The simulated device was fabricated on a high-resistivity Si substrate on top of which a layer of GaAs is grown, segmented and patterned to serve as the radiating element. The device's measured return loss indicates a −10 dB BW > 50 GHz and time-domain measurements using a 500 pS input pulse prove that the device is practically non-reverberant in air

  5. Development and characterization of monolithic multilayer Laue lens nanofocusing optics

    Energy Technology Data Exchange (ETDEWEB)

    Nazaretski, E.; Xu, W., E-mail: weihexu@bnl.gov; Bouet, N.; Zhou, J.; Yan, H.; Huang, X.; Chu, Y. S. [Brookhaven National Laboratory, Upton, New York 11973 (United States)

    2016-06-27

    We have developed an experimental approach to bond two independent linear Multilayer Laue Lenses (MLLs) together. A monolithic MLL structure was characterized using ptychography at 12 keV photon energy, and we demonstrated 12 nm and 24 nm focusing in horizontal and vertical directions, respectively. Fabrication of 2D MLL optics allows installation of these focusing elements in more conventional microscopes suitable for x-ray imaging using zone plates, and opens easier access to 2D imaging with high spatial resolution in the hard x-ray regime.

  6. Development and characterization of monolithic multilayer Laue lens nanofocusing optics

    Energy Technology Data Exchange (ETDEWEB)

    Nazaretski, E.; Xu, W.; Bouet, N.; Zhou, J.; Yan, H.; Huang, X.; Chu, Y. S.

    2016-06-27

    We have developed an experimental approach to bond two independent linear Multilayer Laue Lenses (MLLs) together. A monolithic MLL structure was characterized using ptychography at 12 keV photon energy, and we demonstrated 12 nm and 24 nm focusing in horizontal and vertical directions, respectively. Fabrication of 2D MLL optics allows installation of these focusing elements in more conventional microscopes suitable for x-ray imaging using zone plates, and opens easier access to 2D imaging with high spatial resolution in the hard x-ray regime.

  7. Photodetectors and monolithic optical receivers in silicon technologies

    Science.gov (United States)

    Schaub, Jeremy Daniel

    Long-distance, high-performance optical data links operate at 1.55mum to take advantage of the low loss of optical fibers at this wavelength. Shorter distance optical links can be implemented at wavelengths near 850nm to take advantage of low-cost optical devices based on GaAs technology. Since silicon (Si) also detects light at this wavelength, it is possible to use Si-based receivers to further reduce costs and to benefit from the advanced manufacturability and proven reliability of Si technology. In this dissertation, I discuss the design, fabrication and performance characteristics of Si-based photodetectors and monolithically integrated optical receivers. This discussion includes a description of a resonant-cavity-enhanced p-i-n photodiode grown using a selective epitaxial growth technique. The device demonstrated peak quantum efficiencies of 42% at 704nm and 31% at 830nm and a bandwidth exceeding 34GHz at -5V. This is the highest speed reported for a Si p-i-n photodiode and the highest bandwidth-efficiency product for any Si-based photodetector. Two monolithically integrated photoreceivers are also described. The first, a lateral p-i-n photodiode integrated with an NMOS transimpedance amplifier on a high-resistivity Si substrate, achieved a bit error ratio of 10-9 at an incident optical power of -31.8dBm at 622Mb/s and -23.2dBm at 1.0Gb/s. This is the highest reported sensitivity of any Si-based monolithic photoreceiver at these data rates. The slow response of the photodiode, which required a -30V bias, limited the overall speed of the receiver. A similar receiver was fabricated on a 3.0mum-thick silicon-on-insulator (SOI) substrate to improve the speed and lower the operating voltage of the photodiode. This receiver demonstrated a maximum operating speed of 2.0Gb/s with a sensitivity of -12.2dBm. This is the fastest speed reported for a monolithic Si receiver in MOS technology. The sensitivities at 622Mb/s and 1.0Gb/s were -26.2dBm and -20.3d

  8. A hybrid FIA/HPLC system incorporating monolithic column chromatography

    International Nuclear Information System (INIS)

    Adcock, Jacqui L.; Francis, Paul S.; Agg, Kent M.; Marshall, Graham D.; Barnett, Neil W.

    2007-01-01

    We have combined the generation of solvent gradients using milliGAT pumps, chromatographic separations with monolithic columns and chemiluminescence detection in an instrument manifold that approaches the automation and separation efficiency of HPLC, whilst maintaining the positive attributes of flow injection analysis (FIA), such as manifold versatility, speed of analysis and portability. As preliminary demonstrations of this hybrid FIA/HPLC system, we have determined six opiate alkaloids (morphine, pseudomorphine, codeine, oripavine, ethylmorphine and thebaine) and four biogenic amines (vanilmandelic acid, serotonin, 5-hydroxyindole-3-acetic acid and homovanillic acid) in human urine, using tris(2,2'-bipyridyl)ruthenium(III) and acidic potassium permanganate chemiluminescence detection

  9. THE PECULIARITIES OF DESIGNING OF MONOLITHIC FOUNDATION SLABS IN BANGLADESH

    Directory of Open Access Journals (Sweden)

    Анна Николаевна Малахова

    2017-05-01

    Full Text Available The climatic and engineering-geological conditions of the construction sites for civil buildings in the People's Republic of Bangladesh are considered. There are described the features of the constructive solution of load-bearing structures of buildings of mass urban development. Monolithic reinforced concrete buildings of medium height of column and wall construction systems are considered, and the average ground pressure is determined. There are shown the slabs foundations of such buildings, the features of their design and reinforcement, including under the conditions of seismic influences.

  10. Preparation and application of novel zwitterionic monolithic column for hydrophilic interaction chromatography.

    Science.gov (United States)

    Liu, Zhenghua; Peng, Yongbo; Wang, Tingting; Yuan, Guangxin; Zhang, Qiaoxuan; Guo, Jialiang; Jiang, Zhengjin

    2013-01-01

    A novel zwitterionic hydrophilic porous monolithic stationary phase was prepared based on the thermal-initiated copolymerization of N,N-dimethyl-N-(3-methacryl-amidopropyl)-N-(3-(sulfopropyl)ammonium betaine and ethylene glycol dimethacrylate. A typical hydrophilic separation mechanism was observed at a highly organic mobile phase (ACN >60%) on this optimized zwitterionic hydrophilic interaction chromatography (HILIC) monolithic stationary phase. Good permeability, stability, and column efficiency were observed on the final monolithic column. Additionally, a weak electrostatic interaction for charged analytes was confirmed in analysis of six benzoic acids by studying the influence of mobile phase pH and salt concentration on their retention behaviors on the obtained zwitterionic HILIC monolithic column. The optimized zwitterionic HILIC monolith exhibited good selectivity for a range of polar test analytes. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Recent advances in preparation and application of hybrid organic-silica monolithic capillary columns.

    Science.gov (United States)

    Ou, Junjie; Lin, Hui; Zhang, Zhenbin; Huang, Guang; Dong, Jing; Zou, Hanfa

    2013-01-01

    Hybrid organic-silica monolithic columns, regarded as a second generation of silica-based monoliths, have received much interest due to their unique properties over the pure silica-based monoliths. This review mainly focuses on development in the fields of preparation of hybrid monolithic columns in a capillary and their application for CEC and capillary liquid chromatography separation, as well as for sample pretreatment of solid-phase microextraction and immobilized enzyme reactor since July 2010. The preparation approaches are comprehensively summarized with three routes: (i) general sol-gel process using trialkoxysilanes and tetraalkoxysilanes as coprecursors; (ii) "one-pot" process of alkoxysilanes and organic monomers concomitantly proceeding sol-gel chemistry and free radical polymerization; and (iii) other polymerization approaches of organic monomers containing silanes. The modification of hybrid monoliths containing reactive groups to acquire the desired surface functionality is also described. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. [Preparation of chiral monolithic column with covalently bonded cellulose and their application to rapid enantioseparation].

    Science.gov (United States)

    Wang, Jiabin; Wang, Xiao; Li, Jianhua; Lü, Haixia; Lin, Xucong; Xie, Zenghong; Zhang, Qiqing

    2011-12-01

    A chiral monolithic capillary column for rapid enantioseparation was prepared by covalently bonding of cellulose tris(4-methylbenzoate) (CTMB) on N-acryloxysuccinimide-based monolith. The preparation and derivatization conditions of the monolithic column were optimized. The successful grafting of CTMB was confirmed on the characterizations of the infrared spectrum and the cathodic electroosmotic flow (EOF). The effects of acetic acid concentration and methanol content on the enantioseparation were studied. The solvent resistance, reproducibility and stability of the monolithic column have also been investigated. The rapid enantioseparation of the five solutes (phenylalanine, tyrosine, tryptophan, propranolol and phenylethanol) with resolution (R(s)) values up to 1.31 was achieved within 1.2 min on the prepared chiral capillary monolithic column by capillary electrochromatography.

  13. Preparation and application of organic-silica hybrid monolithic capillary columns.

    Science.gov (United States)

    Wu, Minghuo; Wu, Ren'an; Zhang, Zhenbin; Zou, Hanfa

    2011-01-01

    Organic-silica hybrid monolithic columns have drawn more and more attention due to the ease of preparation and good mechanical stability in recent years. Many synthetic approaches have been developed and a variety of hybrid monolithic capillary columns have been prepared. The sol-gel process is well recognized in the fabrication of hybrid monolithic columns, which can be mainly classified as one-step, acid/base two-step procedures. The new approaches such as the "one-pot" and nano-scaled inorganic-organic hybrid reagent of polyhedral oligomeric silsesquioxane used as a cross-linker have also emerged for the preparation of hybrid monolithic columns. The applications of the organic-silica hybrid monolithic capillary columns for capillary electrochromatography, micro high-performance liquid chromatography, solid-phase micro-extraction and enzymatic reactor etc. are included in this review. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Position and time resolution measurements with a microchannel plate image intensifier: A comparison of monolithic and pixelated CeBr{sub 3} scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Ackermann, Ulrich, E-mail: ulrich.ackermann@unibw.de [Universität der Bundeswehr München, Institut für angewandte Physik und Messtechnik (LRT2), Werner-Heisenberg-Weg 39, 85577 Neubiberg (Germany); Eschbaumer, Stephan, E-mail: stephan.eschbaumer@unibw.de [Universität der Bundeswehr München, Institut für angewandte Physik und Messtechnik (LRT2), Werner-Heisenberg-Weg 39, 85577 Neubiberg (Germany); Bergmaier, Andreas, E-mail: andreas.bergmaier@unibw.de [Universität der Bundeswehr München, Institut für angewandte Physik und Messtechnik (LRT2), Werner-Heisenberg-Weg 39, 85577 Neubiberg (Germany); Egger, Werner, E-mail: werner.egger@unibw.de [Universität der Bundeswehr München, Institut für angewandte Physik und Messtechnik (LRT2), Werner-Heisenberg-Weg 39, 85577 Neubiberg (Germany); Sperr, Peter, E-mail: peter.sperr@unibw.de [Universität der Bundeswehr München, Institut für angewandte Physik und Messtechnik (LRT2), Werner-Heisenberg-Weg 39, 85577 Neubiberg (Germany); Greubel, Christoph, E-mail: christoph.greubel@unibw.de [Universität der Bundeswehr München, Institut für angewandte Physik und Messtechnik (LRT2), Werner-Heisenberg-Weg 39, 85577 Neubiberg (Germany); and others

    2016-07-01

    To perform Four Dimensional Age Momentum Correlation measurements in the near future, where one obtains the positron lifetime in coincidence with the three dimensional momentum of the electron annihilating with the positron, we have investigated the time and position resolution of two CeBr{sub 3} scintillators (monolithic and an array of pixels) using a Photek IPD340/Q/BI/RS microchannel plate image intensifier. The microchannel plate image intensifier has an active diameter of 40 mm and a stack of two microchannel plates in chevron configuration. The monolithic CeBr{sub 3} scintillator was cylindrically shaped with a diameter of 40 mm and a height of 5 mm. The pixelated scintillator array covered the whole active area of the microchannel plate image intensifier and the shape of each pixel was 2.5·2.5·8 mm{sup 3} with a pixel pitch of 3.3 mm. For the monolithic setup the measured mean single time resolution was 330 ps (FWHM) at a gamma energy of 511 keV. No significant dependence on the position was detected. The position resolution at the center of the monolithic scintillator was about 2.5 mm (FWHM) at a gamma energy of 662 keV. The single time resolution of the pixelated crystal setup reached 320 ps (FWHM) in the region of the center of the active area of the microchannel plate image intensifier. The position resolution was limited by the cross-section of the pixels. The gamma energy for the pixel setup measurements was 511 keV.

  15. Optimising reversed-phase liquid chromatographic separation of an acidic mixture on a monolithic stationary phase with the aid of response surface methodology and experimental design.

    Science.gov (United States)

    Wang, Y; Harrison, M; Clark, B J

    2006-02-10

    An optimization strategy for the separation of an acidic mixture by employing a monolithic stationary phase is presented, with the aid of experimental design and response surface methodology (RSM). An orthogonal array design (OAD) OA(16) (2(15)) was used to choose the significant parameters for the optimization. The significant factors were optimized by using a central composite design (CCD) and the quadratic models between the dependent and the independent parameters were built. The mathematical models were tested on a number of simulated data set and had a coefficient of R(2) > 0.97 (n = 16). On applying the optimization strategy, the factor effects were visualized as three-dimensional (3D) response surfaces and contour plots. The optimal condition was achieved in less than 40 min by using the monolithic packing with the mobile phase of methanol/20 mM phosphate buffer pH 2.7 (25.5/74.5, v/v). The method showed good agreement between the experimental data and predictive value throughout the studied parameter space and were suitable for optimization studies on the monolithic stationary phase for acidic compounds.

  16. Less common applications of monoliths: V. Monolithic scaffolds modified with nanostructures for chromatographic separations and tissue engineering

    Czech Academy of Sciences Publication Activity Database

    Křenková, Jana; Foret, František; Švec, F.

    2012-01-01

    Roč. 35, 10-11 (2012), s. 1266-1283 ISSN 1615-9306 R&D Projects: GA ČR(CZ) GBP206/12/G014; GA ČR(CZ) GAP301/11/2055 Grant - others:Jihomoravský kraj(CZ) 2SGA2721 Program:2SGA Institutional research plan: CEZ:AV0Z40310501 Keywords : nanoparticles * monoliths * separation Subject RIV: CB - Analytical Chemistry, Separation Impact factor: 2.591, year: 2012 http://onlinelibrary.wiley.com/doi/10.1002/jssc.201100956/pdf

  17. Single-grain feldspar luminescence chronology of historical extreme wave event deposits recorded in a coastal lowland, Pacific coast of central Japan

    DEFF Research Database (Denmark)

    Riedesel, Svenja; Brill, Dominik; Roberts, Helen M.

    2018-01-01

    The Shirasuka lowlands, located on the Enshu-nada coast of central Japan, record evidence for numerous extreme wave events. Here we test the applicability of using the luminescence signal from feldspars to date these young (

  18. Effectiveness of optical illusions 
applied on a single composite resin veneer for the diastema closure 
of maxillary central incisors.

    Science.gov (United States)

    Katsarou, Thomai; Antoniadou, Maria; Papazoglou, Efstratios

    To assess the esthetic effectiveness of four illusion techniques applied to a composite resin veneer for diastema closure between maxillary central incisors. An acrylic model with six natural maxillary anterior teeth was fabricated with a 2-mm diastema between the central incisors. Resin veneers were constructed on the left central incisor and the following cases were derived: V0: no veneer; V1: veneer without optical illusion features; V2: veneer with centralized interproximal ridges; V3: veneer with curved incisal edges; V4: veneer with gray pigment mesially/distally; V5: veneer with gray pigment on the developmental lobes. Digital printed photos of the models (13.2 x 17.8 cm, and 6.1 x 8 cm), with low, medium, and high smile lines and without a smile line (processed by Adobe Photoshop CS6) were shown to three groups of people (faculty members, senior undergraduate students, and patients; n = 25/group) for them to assess the overall size and width of the two central incisors. The results were analyzed by Pearson's and chi-square goodness of fit tests. There was no significant influence in the estimation of the two central incisors as being the same size, according to the technique used (P = 0.869) and group of evaluators (P = 0.209). The estimated probability of assessing the tested incisor as wider was indicatively lower in V2 compared to V1 (adjusted odds ratio = 0.59; P = 0.088). The height of the smile line affected the evaluation of the veneers only in the large-sized photos. No interference is the best esthetic decision concerning a 2-mm diastema closure when restoring only one central incisor with a laminate veneer. The next best option is to deliver a veneer with centralized interproximal ridges.

  19. The preparation method of terahertz monolithic integrated device

    Science.gov (United States)

    Zhang, Cong; Su, Bo; He, Jingsuo; Zhang, Hongfei; Wu, Yaxiong; Zhang, Shengbo; Zhang, Cunlin

    2018-01-01

    The terahertz monolithic integrated device is to integrate the pumping area of the terahertz generation, the detection area of the terahertz receiving and the metal waveguide of terahertz transmission on the same substrate. The terahertz generation and detection device use a photoconductive antenna structure the metal waveguide use a microstrip line structure. The evanescent terahertz-bandwidth electric field extending above the terahertz transmission line interacts with, and is modified by, overlaid dielectric samples, thus enabling the characteristic vibrational absorption resonances in the sample to be probed. In this device structure, since the semiconductor substrate of the photoconductive antenna is located between the strip conductor and the dielectric layer of the microstrip line, and the semiconductor substrate cannot grow on the dielectric layer directly. So how to prepare the semiconductor substrate of the photoconductive antenna and how to bond the semiconductor substrate to the dielectric layer of the microstrip line is a key step in the terahertz monolithic integrated device. In order to solve this critical problem, the epitaxial wafer structure of the two semiconductor substrates is given and transferred to the desired substrate by two methods, respectively.

  20. Optimization of lytic phage manufacturing in bioreactor using monolithic supports.

    Science.gov (United States)

    Smrekar, Franc; Ciringer, Mateja; Jančar, Janez; Raspor, Peter; Štrancar, Aleš; Podgornik, Aleš

    2011-08-01

    A process for manufacturing large quantities of lytic bacteriophages was developed. Determination of cultivation termination was found to be essential to achieve high phage quantity and purity. When optimal cultivation termination is missed, phage fraction was found to be highly contaminated with deoxyribonucleic acid released from Escherichia coli cells. Besides, an already established method for monitoring of phage cultivation based on optical density, where its peak indicates point when maximal phage titer is achieved, a new indirect chromatographic method using methacrylate monoliths is proposed for on-line estimation of phage titer. It is based on the measurement of released E. coli deoxyribonucleic acid and shows high correlation with phage titer obtained from plaque assay. Its main advantage is that the information is obtained within few minutes. In addition, the same method can also be used to determine purity of a final phage fraction. Two strategies to obtain highly pure phage fractions are proposed: an immediate purification of phage lysate using monolithic columns or an addition of EDTA before chromatographic purification. The developed protocol was shown to give phage purity above 90% and it is completed within one working day including cultivation and phage titer in the final formulation using developed chromatographic method. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Monolithic Active Pixel Matrix with Binary Counters (MAMBO) ASIC

    International Nuclear Information System (INIS)

    Khalid, Farah F.; Deptuch, Grzegorz; Shenai, Alpana; Yarema, Raymond J.

    2010-01-01

    Monolithic Active Matrix with Binary Counters (MAMBO) is a counting ASIC designed for detecting and measuring low energy X-rays from 6-12 keV. Each pixel contains analogue functionality implemented with a charge preamplifier, CR-RC 2 shaper and a baseline restorer. It also contains a window comparator which can be trimmed by 4 bit DACs to remove systematic offsets. The hits are registered by a 12 bit ripple counter which is reconfigured as a shift register to serially output the data from the entire ASIC. Each pixel can be tested individually. Two diverse approaches have been used to prevent coupling between the detector and electronics in MAMBO III and MAMBO IV. MAMBO III is a 3D ASIC, the bottom ASIC consists of diodes which are connected to the top ASIC using μ-bump bonds. The detector is decoupled from the electronics by physically separating them on two tiers and using several metal layers as a shield. MAMBO IV is a monolithic structure which uses a nested well approach to isolate the detector from the electronics. The ASICs are being fabricated using the SOI 0.2 (micro)m OKI process, MAMBO III is 3D bonded at T-Micro and MAMBO IV nested well structure was developed in collaboration between OKI and Fermilab.

  2. Monolithic Active Pixel Matrix with Binary Counters (MAMBO) ASIC

    Energy Technology Data Exchange (ETDEWEB)

    Khalid, Farah F.; Deptuch, Grzegorz; Shenai, Alpana; Yarema, Raymond J.; /Fermilab

    2010-11-01

    Monolithic Active Matrix with Binary Counters (MAMBO) is a counting ASIC designed for detecting and measuring low energy X-rays from 6-12 keV. Each pixel contains analogue functionality implemented with a charge preamplifier, CR-RC{sup 2} shaper and a baseline restorer. It also contains a window comparator which can be trimmed by 4 bit DACs to remove systematic offsets. The hits are registered by a 12 bit ripple counter which is reconfigured as a shift register to serially output the data from the entire ASIC. Each pixel can be tested individually. Two diverse approaches have been used to prevent coupling between the detector and electronics in MAMBO III and MAMBO IV. MAMBO III is a 3D ASIC, the bottom ASIC consists of diodes which are connected to the top ASIC using {mu}-bump bonds. The detector is decoupled from the electronics by physically separating them on two tiers and using several metal layers as a shield. MAMBO IV is a monolithic structure which uses a nested well approach to isolate the detector from the electronics. The ASICs are being fabricated using the SOI 0.2 {micro}m OKI process, MAMBO III is 3D bonded at T-Micro and MAMBO IV nested well structure was developed in collaboration between OKI and Fermilab.

  3. Evaluation of C18 monolithic columns for radiochemical purity measurement.

    Science.gov (United States)

    Schenk, David J; Welch, Christopher J; Antonucci, Vincent

    2016-08-01

    Speeding the analysis of reaction aliquots, high-performance liquid chromatography (HPLC) fractions and final products continue to be an area of great interest in the study of radiopharmaceuticals. Translating recently developed rapid HPLC and ultra high-performance liquid chromatography analysis approaches to radio-HPLC can sometimes be fraught with peril, owing to specific peculiarities of online radiochemical chromatographic detection (notably, a proportionally large system volume for the radio-HPLC detector). In this study, we investigate an alternate approach for rapid radio-HPLC analysis where a 150-cm C18 monolithic column is used with a 15-min run time. To ascertain this method's ability to distinguish between radiolabeled compounds with acceptable (≥97%) and unacceptable purity, the results were compared with results from a conventional HPLC 45-min method using a 25-cm C18 column, where a large radiodetector cell volume is of lower impact. Overall, for the 54 radiolabeled compounds assayed by the two methods, there were similar measured radiochemical purities, but cases were also found where there were significantly large differences between the results (>1%). A calculated confidence of ~85% was found for the 15-min monolithic method's ability to accurately reproduce the corresponding result from the 25-cm column method. Copyright © 2016 John Wiley & Sons, Ltd.

  4. Affinity monolith chromatography: A review of general principles and applications.

    Science.gov (United States)

    Li, Zhao; Rodriguez, Elliott; Azaria, Shiden; Pekarek, Allegra; Hage, David S

    2017-11-01

    Affinity monolith chromatography, or AMC, is a liquid chromatographic method in which the support is a monolith and the stationary phase is a biological-binding agent or related mimic. AMC has become popular for the isolation of biochemicals, for the measurement of various analytes, and for studying biological interactions. This review will examine the principles and applications of AMC. The materials that have been used to prepare AMC columns will be discussed, which have included various organic polymers, silica, agarose, and cryogels. Immobilization schemes that have been used in AMC will also be considered. Various binding agents and applications that have been reported for AMC will then be described. These applications will include the use of AMC for bioaffinity chromatography, immunoaffinity chromatography, dye-ligand affinity chromatography, and immobilized metal-ion affinity chromatography. The use of AMC with chiral stationary phases and as a tool to characterize biological interactions will also be examined. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. The market of huge monolithic mirror substrates for optical astronomy

    Science.gov (United States)

    Döhring, Thorsten

    2013-09-01

    Professional astronomical telescopes are complex optical systems at the limit of technical feasibility. Often monolithic primary mirrors and sometimes even secondary mirrors with huge dimensions are used. Prominent examples are the two reflectors of the Large Binocular Telescope and the giant mirrors of VLT, GEMINI, and SUBARU. The performance of such precision optical components significantly depends on the physical parameters and the quality of their substrate materials. Within this paper selection criteria for mirror substrates will be discussed, thereby considering the important technical parameters as well as commercial points and aspects of project management. Qualities and limitations of classical mirror substrate materials like Zerodur, ULE, Sitall, borosilicate glass and Cervit will be evaluated and compared to new substrate materials like silicon carbide and beryllium. The different suppliers and their production processes are presented. In addition large mirrors of existing observatories and of telescopes under construction will be listed, thereby concentrating on mirrors above three meter in diameter. An outlook on material trends and on future astronomical telescopes closes this overview on the market of huge monolithic mirror substrates for optical astronomy.

  6. Macroporous monoliths for trace metal extraction from seawater

    Energy Technology Data Exchange (ETDEWEB)

    Yue, Yanfeng; Mayes, Richard; Gill, Gary A.; Kuo, Li-Jung; Wood, Jordana R.; Binder, Andrew; Brown, Suree; Dai, Sheng

    2015-05-29

    The viability of seawater-based uranium recovery depends on the uranium adsorption rate and capacity, since the concentration of uranium in the oceans is relatively low (3.3 μgL⁻¹). An important consideration for a fast adsorption is to maximize the adsorption properties of adsorbents such as surface areas and pore structures, which can greatly improve the kinetics of uranium extraction and the adsorption capacity simultaneously. Following this consideration, macroporous monolith adsorbents were prepared from the copolymerization of acrylonitrile (AN) and N,N’-methylenebis(acrylamide) (MBAAm) based on a cryogel method using both hydrophobic and hydrophilic monomers. The monolithic sorbents were tested with simulated seawater containing a high uranyl concentration (–6 ppm) and the uranium adsorption results showed that the adsorption capacities are strongly influenced by the ratio of monomer to the crosslinker, i.e., the density of the amidoxime groups. The preliminary seawater testing indicates the high salinity content of seawater does not hinder the adsorption of uranium.

  7. Development of stable monolithic wide-field Michelson interferometers.

    Science.gov (United States)

    Wan, Xiaoke; Ge, Jian; Chen, Zhiping

    2011-07-20

    Bulk wide-field Michelson interferometers are very useful for high precision applications in remote sensing and astronomy. A stable monolithic Michelson interferometer is a key element in high precision radial velocity (RV) measurements for extrasolar planets searching and studies. Thermal stress analysis shows that matching coefficients of thermal expansion (CTEs) is a critical requirement for ensuring interferometer stability. This requirement leads to a novel design using BK7 and LAK7 materials, such that the monolithic interferometer is free from thermal distortion. The processes of design, fabrication, and testing of interferometers are described in detail. In performance evaluations, the field angle is typically 23.8° and thermal sensitivity is typically -2.6×10(-6)/°C near 550 nm, which corresponds to ∼800 m/s/°C in the RV scale. Low-cost interferometer products have been commissioned in multiple RV instruments, and they are producing high stability performance over long term operations. © 2011 Optical Society of America

  8. Immobilization of trypsin on sub-micron skeletal polymer monolith

    Energy Technology Data Exchange (ETDEWEB)

    Yao Chunhe [Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Graduate School, Chinese Academy of Sciences, Beijing 100049 (China); Qi Li, E-mail: qili@iccas.ac.cn [Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Hu Wenbin [Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Graduate School, Chinese Academy of Sciences, Beijing 100049 (China); Wang Fuyi [Beijing National Laboratory for Molecular Sciences, Key Laboratory of Analytical Chemistry for Living Biosystems, Institute of Chemistry, Chinese Academy of Sciences, Beijing 100190 (China); Yang Gengliang [College of Pharmacy, Hebei University, Baoding 071002 (China)

    2011-04-29

    A new kind of immobilized trypsin reactor based on sub-micron skeletal polymer monolith has been developed. Covalent immobilization of trypsin on this support was performed using the epoxide functional groups in either a one- or a multi-step reaction. The proteolytic activity of the immobilized trypsin was measured by monitoring the formation of N-{alpha}-benzoyl-L-arginine (BA) which is the digestion product of a substrate N-{alpha}-benzoyl-L-arginine ethyl ester (BAEE). Results showed that the digestion speed was about 300 times faster than that performed in free solution. The performance of such an enzyme reactor was further demonstrated by digesting protein myoglobin. It has been found that the protein digestion could be achieved in 88 s at 30 deg. C, which is comparable to 24 h digestion in solution at 37 {sup o}C. Furthermore, the immobilized trypsin exhibits increased stability even after continuous use compared to that in free solution. The present monolithic enzyme-reactor provides a promising platform for the proteomic research.

  9. Stable polarization short pulse passively Q-switched monolithic microchip laser with [110] cut Cr4+:YAG

    International Nuclear Information System (INIS)

    Wang, Y; Gong, M; Yan, P; Huang, L; Li, D

    2009-01-01

    A monolithic Nd:YAG microchip laser with [110] cut Cr 4+ :YAG is presented. The output beam is linearly polarized with polarization ratio higher than 100:1. The polarization direction is stable, independent of pump power, crystal temperature, LD temperature. In single longitudinal mode operation, stable 259 ps pulses at 2.5 kHz with 82 kW peak power and diffraction limited beam mode are output. With a simple and compact one-pass Nd:YVO 4 amplifier, 144 kW peak power is achieved. Single longitudinal and fundamental transverse mode is kept after passing through the amplifier stage. The microchip laser can be operated in two longitudinal modes with two sets of output pulses by increasing the pump power

  10. Single frequency semiconductor lasers

    CERN Document Server

    Fang, Zujie; Chen, Gaoting; Qu, Ronghui

    2017-01-01

    This book systematically introduces the single frequency semiconductor laser, which is widely used in many vital advanced technologies, such as the laser cooling of atoms and atomic clock, high-precision measurements and spectroscopy, coherent optical communications, and advanced optical sensors. It presents both the fundamentals and characteristics of semiconductor lasers, including basic F-P structure and monolithic integrated structures; interprets laser noises and their measurements; and explains mechanisms and technologies relating to the main aspects of single frequency lasers, including external cavity lasers, frequency stabilization technologies, frequency sweeping, optical phase locked loops, and so on. It paints a clear, physical picture of related technologies and reviews new developments in the field as well. It will be a useful reference to graduate students, researchers, and engineers in the field.

  11. A 30 Mbps in-plane full-duplex light communication using a monolithic GaN photonic circuit

    Science.gov (United States)

    Gao, Xumin; Yuan, Jialei; Yang, Yongchao; Li, Yuanhang; Yuan, Wei; Zhu, Guixia; Zhu, Hongbo; Feng, Meixin; Sun, Qian; Liu, Yuhuai; Wang, Yongjin

    2017-07-01

    We propose, fabricate and characterize photonic integration of a InGaN/GaN multiple-quantum-well light-emitting diode (MQW-LED), waveguide, ring resonator and InGaN/GaN MQW-photodiode on a single chip, in which the photonic circuit is suspended by the support beams. Both experimental observations and simulation results illustrate the manipulation of in-plane light coupling and propagation by the waveguide and the ring resonator. The monolithic photonic circuit forms an in-plane data communication system using visible light. When the two suspended InGaN/GaN MQW-diodes simultaneously serve as the transmitter and the receiver, an in-plane full-duplex light communication is experimentally demonstrated with a transmission rate of 30 Mbps, and the superimposed signals are extracted using the self-interference cancellation method. The suspended photonic circuit creates new possibilities for exploring the in-plane full-duplex light communication and manufacturing complex GaN-based monolithic photonic integrations.

  12. Sequence-specific DNA solid-phase extraction in an on-chip monolith: Towards detection of antibiotic resistance genes.

    Science.gov (United States)

    Knob, Radim; Nelson, Daniel B; Robison, Richard A; Woolley, Adam T

    2017-11-10

    Antibiotic resistance of bacteria is a growing problem and presents a challenge for prompt treatment in patients with sepsis. Currently used methods rely on culturing or amplification; however, these steps are either time consuming or suffer from interference issues. A microfluidic device was made from black polypropylene, with a monolithic column modified with a capture oligonucleotide for sequence selective solid-phase extraction of a complementary target from a lysate sample. Porous properties of the monolith allow flow and hybridization of a target complementary to the probe immobilized on the column surface. Good flow-through properties enable extraction of a 100μL sample and elution of target DNA in 12min total time. Using a fluorescently labeled target oligonucleotide related to Verona Integron-Mediated Metallo-β-lactamase it was possible to extract and detect a 1pM sample with 83% recovery. Temperature-mediated elution by heating above the duplex melting point provides a clean extract without any agents that interfere with base pairing, allowing various labeling methods or further downstream processing of the eluent. Further integration of this extraction module with a system for isolation and lysis of bacteria from blood, as well as combining with single-molecule detection should allow rapid determination of antibiotic resistance. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Facile preparation of silver nanoparticles homogeneously immobilized in hierarchically monolithic silica using ethylene glycol as reductant.

    Science.gov (United States)

    Yu, Huan; Zhu, Yang; Yang, Hui; Nakanishi, Kazuki; Kanamori, Kazuyoshi; Guo, Xingzhong

    2014-09-07

    A facile and "green" method was proposed to introduce Ag nanoparticles (Ag NPs) into the hierarchically monolithic silica uniformly in the presence of (3-aminopropyl)-triethoxysilane (APTES) and ethylene glycol. APTES is used to modify the monolith by incorporating amino groups onto the surface of meso-macroporous skeletons, while ethylene glycol is employed as the productive reductant. Ag NPs are homogeneously immobilized in hierarchically monolithic silica after reduction and drying at 40 °C for different duration times, and the embedded amount of Ag NPs can reach 15.44 wt% when treated once. The embedment of Ag NPs increases with the repeat treatment and the APTES amount, without uncontrollable crystalline growth. The surface areas of Ag NPs embedded in silica monoliths after heat treatment at 300 and 400 °C are higher than those before heat treatment. The modification via APTES and the embedment of Ag NPs does not spoil the morphology of monolithic silica, while changing the pore structures of the monolith. A tentative formation process and a reduction mechanism are proposed for the modification, reduction and embedment. Ag NPs embedded in monolithic silica is promising for wide applications such as catalysis and separation.

  14. Enthalpy-entropy compensation effect on adsorption of light hydrocarbons on monolithic stationary phases.

    Science.gov (United States)

    Korolev, Alexander A; Shiryaeva, Valeria E; Popova, Tamara P; Kurganov, Alexander A

    2011-08-01

    Enthalpy and entropy of adsorption of light hydrocarbons C1-C4 have been measured for three monoliths of different polarity and for five different carrier gases: helium, hydrogen, nitrogen, carbon dioxide and dinitrogen oxide. Using carrier gas helium the highest values of enthalpy and entropy were observed for monolith based on ethylenedimethacrylate and the lowest values were observed for monolith based on silica, while monolith based on divinylbenzene demonstrated intermediate values. Entropy-enthalpy correlations were observed with carrier gas helium for all thee monoliths and possess similar slope indicating similar adsorption mechanism on all monoliths studied. Comparing different carrier gases entropy-enthalpy correlations within a homological series of solutes were observed for light carrier gases (He, H2 and N2) and were not observed for heavy carrier gases (CO2 and N2O). Instead, entropy-enthalpy correlations for heavy carrier gases were observed with pressure as variable and the higher the carrier gas pressure the lower the values of enthalpy and entropy observed. The observed changes in entropy-enthalpy correlations were explained by competitive adsorption of heavy carrier gas on monoliths. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Monolithic columns with immobilized monomeric avidin: preparation and application for affinity chromatography.

    Science.gov (United States)

    Spross, Jens; Sinz, Andrea

    2012-03-01

    A poly(glycidyl methacrylate-co-acrylamide-co-ethylene dimethacrylate) monolith and a poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith were prepared in fused silica capillaries (100 μm ID) and modified with monomeric avidin using the glutaraldehyde technique. The biotin binding capacity of monolithic affinity columns with immobilized monomeric avidin (MACMAs) was determined by fluorescence spectroscopy using biotin (5-fluorescein) conjugate, as well as biotin- and fluorescein-labeled bovine serum albumin (BSA). The affinity columns were able to bind 16.4 and 3.7 μmol biotin/mL, respectively. Columns prepared using the poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith retained 7.1 mg BSA/mL, almost six times more than commercially available monomeric avidin beads. Protocols based on MALDI-TOF mass spectrometry monitoring were optimized for the enrichment of biotinylated proteins and peptides. A comparison of enrichment efficiencies between MACMAs and commercially available monomeric avidin beads yielded superior results for our novel monolithic affinity columns. However, the affinity medium presented in this work suffers from a significant degree of nonspecific binding, which might hamper the analysis of more complex mixtures. Further modifications of the monolith's surface are envisaged for the future development of monoliths with improved enrichment characteristics.

  16. Synthesis and characterization of hierarchically porous metal, metal oxide, and carbon monoliths with highly ordered nanostructure

    Science.gov (United States)

    Grano, Amy Janine

    Hierarchically porous materials are of great interest in such applications as catalysis, separations, fuel cells, and advanced batteries. One such way of producing these materials is through the process of nanocasting, in which a sacrificial template is replicated and then removed to form a monolithic replica. This replica consists of mesopores, which can be ordered or disordered, and bicontinuous macropores, which allow flow throughout the length of the monolith. Hierarchically porous metal oxide and carbon monoliths with an ordered mesopores system are synthesized for the first time via nanocasting. These replicas were used as supports for the deposition of silver particles and the catalytic efficiency was evaluated. The ordered silica template used in producing these monoliths was also used for an in-situ TEM study involving metal nanocasting, and an observation of the destruction of the silica template during nanocasting made. Two new methods of removing the silica template were developed and applied to the synthesis of copper, nickel oxide, and zinc oxide monoliths. Finally, hollow fiber membrane monoliths were examined via x-ray tomography in an attempt to establish the presence of this structure throughout the monolith.

  17. Sub-200 ps CRT in monolithic scintillator PET detectors using digital SiPM arrays and maximum likelihood interaction time estimation

    International Nuclear Information System (INIS)

    Van Dam, Herman T; Borghi, Giacomo; Seifert, Stefan; Schaart, Dennis R

    2013-01-01

    Digital silicon photomultiplier (dSiPM) arrays have favorable characteristics for application in monolithic scintillator detectors for time-of-flight positron emission tomography (PET). To fully exploit these benefits, a maximum likelihood interaction time estimation (MLITE) method was developed to derive the time of interaction from the multiple time stamps obtained per scintillation event. MLITE was compared to several deterministic methods. Timing measurements were performed with monolithic scintillator detectors based on novel dSiPM arrays and LSO:Ce,0.2%Ca crystals of 16 × 16 × 10 mm 3 , 16 × 16 × 20 mm 3 , 24 × 24 × 10 mm 3 , and 24 × 24 × 20 mm 3 . The best coincidence resolving times (CRTs) for pairs of identical detectors were obtained with MLITE and measured 157 ps, 185 ps, 161 ps, and 184 ps full-width-at-half-maximum (FWHM), respectively. For comparison, a small reference detector, consisting of a 3 × 3 × 5 mm 3 LSO:Ce,0.2%Ca crystal coupled to a single pixel of a dSiPM array, was measured to have a CRT as low as 120 ps FWHM. The results of this work indicate that the influence of the optical transport of the scintillation photons on the timing performance of monolithic scintillator detectors can at least partially be corrected for by utilizing the information contained in the spatio-temporal distribution of the collection of time stamps registered per scintillation event. (paper)

  18. Semi-high-throughput isolation and N-glycan analysis of human fibrinogen using monolithic supports bearing monoclonal anti-human fibrinogen antibodies.

    Science.gov (United States)

    Vidic, Urška; Trbojević-Akmačić, Irena; Černigoj, Urh; Albers, Malena; Gašperšič, Jernej; Pučić-Baković, Maja; Vidič, Jana; Štrancar, Aleš; Lauc, Gordan

    2017-11-01

    Fibrinogen (FIB) is a secretory glycoprotein synthesized by hepatocytes that has a key role in blood clotting. Its glycosylation has not been studied in detail and little is known about the biological variability of FIB N-glycosylation, mainly due to the lack of fast, simple, and robust approaches to purify FIB from blood plasma samples. In recent years, customised chromatographic monoliths have been used for a variety of biological applications due to their unique characteristics. Here we describe development and optimisation of monolithic supports bearing monoclonal anti-human fibrinogen antibodies in a single column as well as in multi-well plate formats with high FIB specificity and binding capacity for fast immunoaffinity purification of FIB from human blood samples. The developed semi-high-throughput workflow has been successfully applied for FIB immunoaffinity isolation and subsequent ultra performance liquid chromatography N-glycosylation analysis in ten healthy human individuals, demonstrating the potential of monolithic supports in glycomics studies. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Comparison of perfusion media and monoliths for protein and virus-like particle chromatography.

    Science.gov (United States)

    Wu, Yige; Abraham, Dicky; Carta, Giorgio

    2016-05-20

    Structural and performance characteristics of perfusion chromatography media (POROS HS 20 and 50) and those of a polymethacrylate monolith (CIM SO3-1 tube monolith column) are compared for protein and virus-like particle chromatography using 1mL columns. Axial flow columns are used for POROS while the monolith has a radial flow configuration, which provides comparable operating pressures. The POROS beads contain a bimodal distribution of pore sizes, some as large as 0.5μm, which allow a small fraction of the mobile phase to flow within the particles, while the monolith contains 1-2μm flow channels. For proteins (lysozyme and IgG), the dynamic binding capacity of the POROS columns is more than twice that of the monolith at longer residence times. While the DBC of the POROS HS 50 column decreases at shorter residence times, the DBC of the POROS HS 20 column for IgG remains nearly twice that of the monolith at residence times at least as low as 0.2min as a result of intraparticle convection. Protein recoveries are comparable for all three columns. For VLPs, however, the eluted peaks are broader and recovery is lower for the monolith than for the POROS columns and is dependent on the direction of flow in the monolith, which is attributed to denser layer observed by SEM at the inlet surface of the monolith that appears to trap VLPs when loading in the normal flow direction. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Monolitni katalizatori i reaktori: osnovne značajke, priprava i primjena (Monolith catalysts and reactors: preparation and applications

    Directory of Open Access Journals (Sweden)

    Tomašić, V.

    2004-12-01

    Full Text Available Monolithic (honeycomb catalysts are continuous unitary structures containing many narrow, parallel and usually straight channels (or passages. Catalytically active components are dispersed uniformly over the whole porous ceramic monolith structure (so-called incorporated monolithic catalysts or are in a layer of porous material that is deposited on the walls of channels in the monolith's structure (washcoated monolithic catalysts. The material of the main monolithic construction is not limited to ceramics but includes metals, as well. Monolithic catalysts are commonly used in gas phase catalytic processes, such as treatment of automotive exhaust gases, selective catalytic reduction of nitrogen oxides, catalytic removal of volatile organic compounds from industrial processes, etc. Monoliths continue to be the preferred support for environmental applications due to their high geometric surface area, different design options, low pressure drop, high temperature durability, mechanical strength, ease of orientation in a reactor and effectiveness as a support for a catalytic washcoat. As known, monolithic catalysts belong to the class of the structured catalysts and/or reactors (in some cases the distinction between "catalyst" and "reactor" has vanished. Structured catalysts can greatly intensify chemical processes, resulting in smaller, safer, cleaner and more energy efficient technologies. Monolith reactors can be considered as multifunctional reactors, in which chemical conversion is advantageously integrated with another unit operation, such as separation, heat exchange, a secondary reaction, etc. Finally, structured catalysts and/or reactors appear to be one of the most significant and promising developments in the field of heterogeneous catalysis and chemical engineering of the recent years. This paper gives a description of the background and perspectives for application and development of monolithic materials. Different methods and techniques

  1. Charge heterogeneity profiling of monoclonal antibodies using low ionic strength ion-exchange chromatography and well-controlled pH gradients on monolithic columns.

    Science.gov (United States)

    Talebi, Mohammad; Nordborg, Anna; Gaspar, Andras; Lacher, Nathan A; Wang, Qian; He, Xiaoping Z; Haddad, Paul R; Hilder, Emily F

    2013-11-22

    In this work, the suitability of employing shallow pH gradients generated using single component buffer systems as eluents through cation-exchange (CEX) monolithic columns is demonstrated for the high-resolution separation of monoclonal antibody (mAb) charge variants in three different biopharmaceuticals. A useful selection of small molecule buffer species is described that can be used within very narrow pH ranges (typically 1 pH unit) defined by their buffer capacity for producing controlled and smooth pH profiles when used together with porous polymer monoliths. Using very low ionic strength eluents also enabled direct coupling with electrospray ionisation mass spectrometry. The results obtained by the developed pH gradient approach for the separation of closely related antibody species appear to be consistent with those obtained by imaged capillary isoelectric focusing (iCE) in terms of both resolution and separation profile. Both determinants of resolution, i.e., peak compression and peak separation contribute to the gains in resolution, evidently through the Donnan potential effect, which is increased by decreasing the eluent concentration, and also through the way electrostatic charges are distributed on the protein surface. Retention mechanisms based on the trends observed in retention of proteins at pH values higher than the electrophoretic pI are also discussed using applicable theories. Employing monolithic ion-exchangers is shown to enable fast method development, short analysis time, and high sample throughput owing to the accelerated mass transport of the monolithic media. The possibility of short analysis time, typically less than 15 min, and high sample throughput is extremely useful in the assessment of charge-based changes to the mAb products, such as during manufacturing or storage. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Effect of different cement types on monolithic lithium disilicate complete crowns with feather-edge preparation design in the posterior region.

    Science.gov (United States)

    Schmitz, Johannes H; Beani, Massimiliano

    2016-06-01

    Ideally, tooth preparation for complete crowns should require the removal of the smallest amount possible of sound tooth structure to maximize the strength of the remaining tooth. Some preparation designs, such as the feather-edge margin, are less invasive. However, limited data are available regarding monolithic lithium disilicate crowns for molars and premolars with this type of margin geometry. The purpose of this retrospective study was to evaluate the clinical outcome and survival of monolithic lithium disilicate crowns in the posterior region fabricated with feather-edge margins and cemented either with conventional (glass ionomer) or resin self-etching cement in 2 private practices. A total of 257 monolithic lithium disilicate restorations on posterior teeth (108 premolars, 149 molars) were placed in 158 patients. All teeth were prepared with feather-edge margins and restored with single crowns. The modified California Dental Association (CDA) criteria were used to clinically evaluate participants recalled between June and December 2014. The mean ±standard deviation follow-up time was 24 (±13.6; range: 6-75) months. Three crowns were replaced during the follow-up period because of the bulk fracture of the material (98.83% survival rate). No other technical or biological failure was observed. In this retrospective evaluation, monolithic lithium disilicate crowns with feather-edge margins yielded clinical outcomes similar to those reported with other margin designs and materials. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  3. Advancing the Technology of Monolithic CMOS detectors for their use as X-ray Imaging Spectrometers

    Science.gov (United States)

    Kenter, Almus

    The Smithsonian Astrophysical Observatory (SAO) proposes a two year program to further advance the scientific capabilities of monolithic CMOS detectors for use as x-ray imaging spectrometers. This proposal will build upon the progress achieved with funding from a previous APRA proposal that ended in 2013. As part of that previous proposal, x- ray optimized, highly versatile, monolithic CMOS imaging detectors and technology were developed and tested. The performance and capabilities of these devices were then demonstrated, with an emphasis on the performance advantages these devices have over CCDs and other technologies. The developed SAO/SRI-Sarnoff CMOS devices incorporate: Low noise, high sensitivity ("gain") pixels; Highly parallel on-chip signal chains; Standard and very high resistivity (30,000Ohm-cm) Si; Back-Side thinning and passivation. SAO demonstrated the performance benefits of each of these features in these devices. This new proposal high-lights the performance of this previous generation of devices, and segues into new technology and capability. The high sensitivity ( 135uV/e) 6 Transistor (6T) Pinned Photo Diode (PPD) pixels provided a large charge to voltage conversion gain to the detect and resolve even small numbers of photo electrons produced by x-rays. The on-chip, parallel signal chain processed an entire row of pixels in the same time that a CCD requires to processes a single pixel. The resulting high speed operation ( 1000 times faster than CCD) provide temporal resolution while mitigating dark current and allowed room temperature operation. The high resistivity Si provided full (over) depletion for thicker devices which increased QE for higher energy x-rays. In this proposal, SAO will investigate existing NMOS and existing PMOS devices as xray imaging spectrometers. Conventional CMOS imagers are NMOS. NMOS devices collect and measure photo-electrons. In contrast, PMOS devices collect and measure photo-holes. PMOS devices have various

  4. Failure analysis of various monolithic posterior aesthetic dental crowns using finite element method

    Science.gov (United States)

    Porojan, Liliana; Topală, Florin

    2017-08-01

    The aim of the study was to assess the effect of material stiffness and load on the biomechanical performance of the monolithic full-coverage posterior aesthetic dental crowns using finite element analysis. Three restorative materials for monolithic dental crowns were selected for the study: zirconia; lithium disilicate glass-ceramic, and resin-based composite. Stresses were calculated in the crowns for all materials and in the teeth structures, under different load values. The experiments show that dental crowns made from all this new aesthetic materials processed by CAD/CAM technologies would be indicated as monolithic dental crowns for posterior areas.

  5. Stanley Kubrick and B.F. Skinner : Is a Teaching Machine a Monolith ?

    OpenAIRE

    浜野, 保樹; ハマノ, ヤスキ; Yasuki, Hamano

    1990-01-01

    The teaching machine invented by B.F. Skinner was recog-nized as one of few clear achievements of scientific pedagogy and even appeared in SF. Arthur C. Clarke who wrote the script of the SF movie "2001: A Space Odyssey" with Stanley Kubrick wanted to scientifically define a monolith to be a God who had given intelligence to our ancestors. In other words, he wanted to describe a monolith as a teaching machine as well as a God. However Kubrick did not want to make clear about what a monolith i...

  6. Data in support of preparation and functionalization of a clickable polycarbonate monolith

    Directory of Open Access Journals (Sweden)

    Yuanrong Xin

    2016-06-01

    Full Text Available This data article provides supplementary figures to the research article entitled, “Phase separation approach to a reactive polycarbonate monolith for “click” modifications” (Xin et al., Polymer, 2015, doi:10.1016/j.polymer.2015.04.008. Here, the nitrogen adsorption/desorption isotherms of the prepared porous polycarbonate monolith are shown to classify its inner structure and calculate the specific surface area. The monoliths were modified by using the thiol-ene click chemistry and the olefin metathesis, which was examined by contact angle measurements, FT-IR, solid state 13C NMR spectroscopy as well as thermogravimetric analysis.

  7. Monolithically Integrated Electrically Pumped Continuous-Wave III-V Quantum Dot Light Sources on Silicon

    OpenAIRE

    Liao, M.; Chen, S.; Huo, S.; Chen, S.; Wu, J.; Tang, M.; Kennedy, K.; Li, W.; Kumar, S.; Martin, M.; Baron, T.; Jin, C.; Ross, I.; Seeds, A.; Liu, H.

    2017-01-01

    In this paper, we report monolithically integrated IIIV\\ud quantum dot (QD) light-emitting sources on silicon substrates\\ud for silicon photonics. We describe the first practical InAs/GaAs\\ud QD lasers monolithically grown on an offcut silicon (001) substrate\\ud due to the realization of high quality III-V epilayers on silicon with\\ud low defect density, indicating that the large material dissimilarity\\ud between III-Vs and silicon is no longer a fundamental barrier\\ud limiting monolithic gro...

  8. Monolithic active pixel radiation detector with shielding techniques

    Energy Technology Data Exchange (ETDEWEB)

    Deptuch, Grzegorz W.

    2018-03-20

    A monolithic active pixel radiation detector including a method of fabricating thereof. The disclosed radiation detector can include a substrate comprising a silicon layer upon which electronics are configured. A plurality of channels can be formed on the silicon layer, wherein the plurality of channels are connected to sources of signals located in a bulk part of the substrate, and wherein the signals flow through electrically conducting vias established in an isolation oxide on the substrate. One or more nested wells can be configured from the substrate, wherein the nested wells assist in collecting charge carriers released in interaction with radiation and wherein the nested wells further separate the electronics from the sensing portion of the detector substrate. The detector can also be configured according to a thick SOA method of fabrication.

  9. Monolithic silica aerogel - material design on the nano-scale

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev; Schultz, Jørgen Munthe; Kristiansen, Finn Harken

    of piezoelectric transducers. - Other applications could be; waste encapsulation, spacers for vacuum insulation panels, membranes, etc. Department of Civil Engineering is co-ordinator of a current EU FP5 research project1, which deals with the application of aerogel as transparent insulation materials in windows......By means of a production process in two major steps - a sol/gel process and a supercritical drying – open-cell, monolithic silica aerogel can be made. This material can have a density in the range of 30- to 300 kg/m3, corresponding to porosities between 86 and 98 %. The solid structure has...... characteristic dimensions of 2 – 5 nm and the typical pore diameter is about 20 nm. A number of different applications of aerogel have been proposed: - Because of the large internal surface of aerogel (up to 1000 m²/g), the material is proposed to serve as substrate for catalytic materials. - The special pore...

  10. Monolithic Controlled Delivery Systems: Part II. Basic Mathematical Models

    Directory of Open Access Journals (Sweden)

    Rumiana Blagoeva

    2006-12-01

    Full Text Available The article presents a brief but comprehensive review of the large variety of mathematical models of drug controlled release from polymeric monoliths in the last 25 years. The models are considered systematically, from the first simple empirical models up to the most comprehensive theoretical ones taking into account the main release mechanisms (diffusion, swelling, dissolution or erosion simultaneously. Their advantages and limitations are briefly discussed and some applications are outlined. The present review shows the choice of appropriate mathematical model for a particular controlled system design mainly depends on the desired predictive ability and accuracy of the model. This aspect is connected with the necessity the main factors influencing the concrete release kinetics, especially the basic controlling mechanisms, to be identified in advance.

  11. Monolithic Controlled Delivery Systems: Part I. Basic Characteristics and Mechanisms

    Directory of Open Access Journals (Sweden)

    Rumiana Blagoeva

    2006-04-01

    Full Text Available The article considers contemporary systems for controlled delivery of active agents, such as drugs, agricultural chemicals, pollutants and additives in the environment. A useful classification of the available controlled release systems (CRS is proposed according to the type of control (passive, active or self-preprogrammed and according to the main controlling mechanism (diffusion, swelling, dissolution or erosion. Special attention is given to some of the most used CRS - polymer monoliths. The structural and physical-chemical characteristics of CRS as well as the basic approaches to their production are examined. The basic mechanisms of controlled agent release are reviewed in detail and factors influencing the release kinetics are classified according to their importance. The present study can be helpful for understanding and applying the available mathematical models and for developing more comprehensive ones intended for design of new controlled delivery systems.

  12. Optimal parameters of monolithic high-contrast grating mirrors.

    Science.gov (United States)

    Marciniak, Magdalena; Gębski, Marcin; Dems, Maciej; Haglund, Erik; Larsson, Anders; Riaziat, Majid; Lott, James A; Czyszanowski, Tomasz

    2016-08-01

    In this Letter a fully vectorial numerical model is used to search for the construction parameters of monolithic high-contrast grating (MHCG) mirrors providing maximal power reflectance. We determine the design parameters of highly reflecting MHCG mirrors where the etching depth of the stripes is less than two wavelengths in free space. We analyze MHCGs in a broad range of real refractive index values corresponding to most of the common optoelectronic materials in use today. Our results comprise a complete image of possible highly reflecting MHCG mirror constructions for potential use in optoelectronic devices and systems. We support the numerical analysis by experimental verification of the high reflectance via a GaAs MHCG designed for a wavelength of 980 nm.

  13. CMOS Monolithic Active Pixel Sensors (MAPS): Developments and future outlook

    Science.gov (United States)

    Turchetta, R.; Fant, A.; Gasiorek, P.; Esbrand, C.; Griffiths, J. A.; Metaxas, M. G.; Royle, G. J.; Speller, R.; Venanzi, C.; van der Stelt, P. F.; Verheij, H.; Li, G.; Theodoridis, S.; Georgiou, H.; Cavouras, D.; Hall, G.; Noy, M.; Jones, J.; Leaver, J.; Machin, D.; Greenwood, S.; Khaleeq, M.; Schulerud, H.; Østby, J. M.; Triantis, F.; Asimidis, A.; Bolanakis, D.; Manthos, N.; Longo, R.; Bergamaschi, A.

    2007-12-01

    Re-invented in the early 1990s, on both sides of the Atlantic, Monolithic Active Pixel Sensors (MAPS) in a CMOS technology are today the most sold solid-state imaging devices, overtaking the traditional technology of Charge-Coupled Devices (CCD). The slow uptake of CMOS MAPS started with low-end applications, for example web-cams, and is slowly pervading the high-end applications, for example in prosumer digital cameras. Higher specifications are required for scientific applications: very low noise, high speed, high dynamic range, large format and radiation hardness are some of these requirements. This paper will present a brief overview of the CMOS Image Sensor technology and of the requirements for scientific applications. As an example, a sensor for X-ray imaging will be presented. This sensor was developed within a European FP6 Consortium, intelligent imaging sensors (I-ImaS).

  14. Monolithic growth of partly cured polydimethylsiloxane thin film layers

    DEFF Research Database (Denmark)

    Yu, Liyun; Skov, Anne Ladegaard

    2014-01-01

    at different curing times. The monolithic films are investigated by rheology, scanning electron microscope, mechanical testing, dielectric relaxation spectroscopy, thermal gravimetric analysis (TGA) and differential scanning calorimetry (DSC). The morphology, mechanical and dielectric properties, as well...... to enable interlayer crosslinking reactions either by application of an adhesion promoter or by ensuring that there are reactive, complementary sites available on the two surfaces. Polydimethylsiloxane (PDMS) is a widely used polymer for DEAPs. In this work, two-layered PDMS films are adhered together...... as thermal stabilities of the bilayer elastomer films are observed to change with the curing time of the monolayers before lamination. The objective of this work is to create adhesion of two layers without destroying the original viscoelastic properties of the PDMS films, and hence enable, for example...

  15. Design of ultra-lightweight concrete: towards monolithic concrete structures

    Directory of Open Access Journals (Sweden)

    Yu Qing Liang

    2014-04-01

    Full Text Available This study addresses the development of ultra-lightweight concrete. A moderate strength and an excellent thermal conductivity of the lightweight concrete are set as the design targets. The designed lightweight aggregates concrete is targeted to be used in monolithic concrete façade structure, performing as both load bearing element and thermal insulator. The developed lightweight concrete shows excellent thermal properties, with a low thermal conductivity of about 0.12 W/(m·K; and moderate mechanical properties, with 28-day compressive strengths of about 10-12 N/mm . This combination of values exceeds, to the researchers’ knowledge, the performance of all other lightweight building materials. Furthermore, the developed lightweight concrete possesses excellent durability properties.

  16. Monolithic beam splitter in silicon-on-insulator.

    Science.gov (United States)

    Wang, Yongjin; Cheng, Xinli; Lin, Zhilang; Gao, Fan; Zhang, Feng

    2004-10-18

    Inductively coupled plasma reactive ion etching is used to fabricate the monolithic beam splitter in silicon-on-insulator wafer. The near-field image shows that the symmetric 1x2 T-branch works well. The rms roughness of the corner mirror surfaces is measured by atomic force microscope, and the sidewall surface roughness of rib waveguide is evaluated by the corner mirror rms roughness. The scattering losses from the rough sidewall surfaces and the rough mirror surfaces are evaluated to be 0.5 dB/cm and 0.2 dB/mirror, respectively. And the fiber-waveguide insertion loss is measured approximately 5.0 dB.

  17. Thermoresponsive Polyrotaxane Aerogels: Converting Molecular Necklaces into Tough Porous Monoliths.

    Science.gov (United States)

    Wang, Jin; Du, Ran; Zhang, Xuetong

    2018-01-17

    Polyrotaxanes (PRs) are supramolecular systems that combine with several cyclic molecules threaded on a linear molecule, and have been widely applied in molecular abacus, stimuli-responsive systems, self-healing materials, etc. The fabrication of macroscopic porous PR monoliths, which is expected to impart more functions, has not been realized yet. PR aerogels featuring with high specific surface area (232 m 2 /g), high strength (74.7 MPa), and temperature-responsiveness have been synthesized in this work by introducing poly(N-isopropylacrylamide) to the molecular necklaces followed by chemical cross-linking with a rigid cross-linker and supercritical fluid drying in sequence, which might open a new door toward smart macroscopic porous materials.

  18. GaN Monolithic Power Amplifiers for Microwave Backhaul Applications

    Directory of Open Access Journals (Sweden)

    Roberto Quaglia

    2016-06-01

    Full Text Available Gallium nitride integrated technology is very promising not only for wireless applications at mobile frequencies (below 6 GHz but also for network backhaul radiolink deployment, now under deep revision for the incoming 5G generation of mobile communications. This contribution presents three linear power amplifiers realized on 0.25 μ m Gallium Nitride on Silicon Carbide monolithic integrated circuits for microwave backhaul applications: two combined power amplifiers working in the backhaul band around 7 GHz, and a more challenging third one working in the higher 15 GHz band. Architectures and main design steps are described, highlighting the pros and cons of Gallium Nitride with respect to the reference technology which, for these applications, is represented by gallium arsenide.

  19. Inherent polarization entanglement generated from a monolithic semiconductor chip.

    Science.gov (United States)

    Horn, Rolf T; Kolenderski, Piotr; Kang, Dongpeng; Abolghasem, Payam; Scarcella, Carmelo; Della Frera, Adriano; Tosi, Alberto; Helt, Lukas G; Zhukovsky, Sergei V; Sipe, J E; Weihs, Gregor; Helmy, Amr S; Jennewein, Thomas

    2013-01-01

    Creating miniature chip scale implementations of optical quantum information protocols is a dream for many in the quantum optics community. This is largely because of the promise of stability and scalability. Here we present a monolithically integratable chip architecture upon which is built a photonic device primitive called a Bragg reflection waveguide (BRW). Implemented in gallium arsenide, we show that, via the process of spontaneous parametric down conversion, the BRW is capable of directly producing polarization entangled photons without additional path difference compensation, spectral filtering or post-selection. After splitting the twin-photons immediately after they emerge from the chip, we perform a variety of correlation tests on the photon pairs and show non-classical behaviour in their polarization. Combined with the BRW's versatile architecture our results signify the BRW design as a serious contender on which to build large scale implementations of optical quantum processing devices.

  20. Cost and Potential of Monolithic CIGS Photovoltaic Modules

    Energy Technology Data Exchange (ETDEWEB)

    Horowitz, Kelsey; Woodhouse, Michael

    2015-06-17

    A bottom-up cost analysis of monolithic, glass-glass Cu(In,Ga)(Se,S)2 (CIGS) modules is presented, illuminating current cost drivers for this technology and possible pathways to reduced cost. At 14% module efficiency, for the case of U.S. manufacturing, a manufacturing cost of $0.56/WDC and a minimum sustainable price of $0.72/WDC were calculated. Potential for reduction in manufacturing costs to below $0.40/WDC in the long-term may be possible if module efficiency can be increased without significant increase in $/m2 costs. The levelized cost of energy (LCOE) in Phoenix, AZ under different conditions is assessed and compared to standard c-Si.

  1. Monolithic Microwave Integrated Circuit (MMIC) technology for space communications applications

    Science.gov (United States)

    Connolly, Denis J.; Bhasin, Kul B.; Romanofsky, Robert R.

    1987-01-01

    Future communications satellites are likely to use gallium arsenide (GaAs) monolithic microwave integrated-circuit (MMIC) technology in most, if not all, communications payload subsystems. Multiple-scanning-beam antenna systems are expected to use GaAs MMIC's to increase functional capability, to reduce volume, weight, and cost, and to greatly improve system reliability. RF and IF matrix switch technology based on GaAs MMIC's is also being developed for these reasons. MMIC technology, including gigabit-rate GaAs digital integrated circuits, offers substantial advantages in power consumption and weight over silicon technologies for high-throughput, on-board baseband processor systems. For the more distant future pseudomorphic indium gallium arsenide (InGaAs) and other advanced III-V materials offer the possibility of MMIC subsystems well up into the millimeter wavelength region. All of these technology elements are in NASA's MMIC program. Their status is reviewed.

  2. Material Engineering for Monolithic Semiconductor Mode-Locked Lasers

    DEFF Research Database (Denmark)

    Kulkova, Irina

    This thesis is devoted to the materials engineering for semiconductor monolithic passively mode-locked lasers (MLLs) as a compact energy-efficient source of ultrashort optical pulses. Up to the present day, the achievement of low-noise sub-picosecond pulse generation has remained a challenge...... application in MLLs. Improved QW laser performance was demonstrated using the asymmetric barrier layer approach. The analysis of the gain characteristics showed that the high population inversion beneficial for noise reduction cannot be achieved for 10 GHz QW MLLs and would have required lowering the modal....... This work has considered the role of the combined ultrafast gain and absorption dynamics in MLLs as a main factor limiting laser performance. An independent optimization of MLL amplifier and saturable absorber active materials was performed. Two promising approaches were considered: quantum dot (QD...

  3. Monolithically integrated glass microlens scanner using a thermal reflow process

    International Nuclear Information System (INIS)

    Yoo, Sunghyun; Ha, Joon-Geun; Jin, Joo-Young; Kim, Yong-Kweon; Ji, Chang-Hyeon

    2013-01-01

    A monolithically integrated glass microlens optical scanner is presented. A new wafer-level fabrication approach addresses the issue of microlens integration and alignment in conventional microlens integrated devices. A through-silicon plano-convex glass microlens has been fabricated on a silicon substrate prior to the formation of an integrated microlens actuator, realized through two thermal reflow processes at 850 °C. A lateral comb drive is adapted to demonstrate the glass microlens scanner. The 800 µm diameter microlens was laterally shifted up to ±51.6 µm when an ac voltage of 28.5 V in amplitude was applied at a resonant frequency of 1.749 kHz at atmospheric pressure. The optical scanning angle of ±2.0° has been obtained with the fabricated device. (paper)

  4. Low aberration monolithic diffraction gratings for high performance optical spectrometers

    Science.gov (United States)

    Triebel, Peter; Moeller, Tobias; Diehl, Torsten; Gatto, Alexandre; Pesch, Alexander; Erdmann, Lars E.; Burkhardt, Matthias; Kalies, Alexander

    2017-09-01

    Gratings are the core element of the spectrometer. For imaging spectrometers beside the polarization sensitivity and efficiency the imaging quality of the diffraction grating is essential. Lenses and mirrors can be produced with lowest wavefront aberrations. Low aberration imaging quality of the grating is required not to limit the overall imaging quality of the instrument. Different types of spectrometers will lead to different requirements on the wavefront aberrations for their specific diffraction gratings. The wavefront aberration of an optical grating is a combination of the substrate wavefront and the grating wavefront. During the manufacturing process of the grating substrate different processes can be applied in order to minimize the wavefront aberrations. The imaging performance of the grating is also optimized due to the recording setup of the holography. This technology of holographically manufactured gratings is used for transmission and reflection gratings on different types of substrates like prisms, convex and concave spherical and aspherical surface shapes, free-form elements. All the manufactured gratings are monolithic and can be coated with high reflection and anti-reflection coatings. Prism substrates were used to manufacture monolithic GRISM elements for the UV to IR spectral range preferably working in transmission. Besides of transmission gratings, numerous spectrometer setups (e.g. Offner, Rowland circle, Czerny-Turner system layout) working on the optical design principles of reflection gratings. The present approach can be applied to manufacture high quality reflection gratings for the EUV to the IR. In this paper we report our latest results on manufacturing lowest wavefront aberration gratings based on holographic processes in order to enable at least diffraction limited complex spectrometric setups over certain wavelength ranges. Beside the results of low aberration gratings the latest achievements on improving efficiency together with

  5. Highly improved operation of monolithic BGO-PET blocks

    Science.gov (United States)

    Gonzalez-Montoro, A.; Sanchez, F.; Majewski, S.; Zanettini, S.; Benlloch, J. M.; Gonzalez, A. J.

    2017-11-01

    In PET scanners both scintillation crystals and photosensors are key components defining the system's performance and cost. Original PET systems used BGO or NaI(Tl) scintillators but achieved limited performance due to its slow decay and relatively low light output. Moreover, NaI(Tl) has low stopping power for 511 keV annihilation photons. In this study we report the possibility to reintroduce BGO crystals, and in particular in the form of monolithic blocks, especially suitable for low-dose large-size PET scanners, offering significantly improved sensitivity at a highly reduced cost compared to LYSO type fast scintillators. We have studied the performance of a monolithic BGO block as large as 50 × 50 × 15 mm3 with black-painted lateral walls to reduce lights spread, enabling accurate photon depth of interaction (DOI) measurements. A directional optical layer, called retro-reflector, was coupled to the entrance face bouncing back the scintillation light in the direction of the emission source and, therefore, adding to the light signal while preserving the narrow light cone distribution. Four configurations namely 12 × 12 and 16 × 16 SiPM arrays (3 mm × 3 mm each) as photosensors, with or without a nanopattern treatment at the crystal exit face, have been studied. This structure consisted of a thin layer of a specific high refractive index material shaped with a periodic nanopattern, increasing the scintillation light extraction. The readout returned information for each SiPM row and column, characterizing the X-Y light distribution projections. We have studied the detector spatial resolution using collimated 22Na sources at normal incidence. The DOI resolution was evaluated using collimated gamma beams with lateral incidence. The overall best detector performance was obtained for the 16× 16 SiPM array offering higher readout granularity. We have determined the spatial resolution for 3 separated DOI layers, obtaining the best results for the DOI region near to

  6. Single cell cultures of Drosophila neuroectodermal and mesectodermal central nervous system progenitors reveal different degrees of developmental autonomy

    OpenAIRE

    Technau Gerhard M; Lüer Karin

    2009-01-01

    Abstract Background The Drosophila embryonic central nervous system (CNS) develops from two sets of progenitor cells, neuroblasts and ventral midline progenitors, which behave differently in many respects. Neuroblasts derive from the neurogenic region of the ectoderm and form the lateral parts of the CNS. Ventral midline precursors are formed by two rows of mesectodermal cells and build the CNS midline. There is plenty of evidence that individual identities are conferred to precursor cells by...

  7. Testing single-grain quartz OSL methods using sediment samples with independent age control from the Bordes-Fitte rockshelter (Roches d'Abilly site, Central France)

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, Andrew Sean; Buylaert, Jan-Pieter

    2016-01-01

    We present quartz single-grain dose distributions for four well-bleached and unmixed sediment samples with independent age control (22–48 ka), from the archaeologically important Bordes-Fitte rockshelter at Roches d'Abilly, France. This site has previously been dated using 14C AMS dating and stan......We present quartz single-grain dose distributions for four well-bleached and unmixed sediment samples with independent age control (22–48 ka), from the archaeologically important Bordes-Fitte rockshelter at Roches d'Abilly, France. This site has previously been dated using 14C AMS dating...

  8. A Monolithic, Non-Field-Widened Spatial Heterodyne Spectrometer for Solar System Exploration, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal of this project is to produce a monolithic Spatial Heterodyne Spectrometer (a Fourier Transform Interferometer) for use in Solar System exploration. In...

  9. Recent developments and applications of molecularly imprinted monolithic column for HPLC and CEC.

    Science.gov (United States)

    Zheng, Chao; Huang, Yan-Ping; Liu, Zhao-Sheng

    2011-08-01

    As a new generation of stationary phases, monolithic supports have attracted significant interest in high-performance liquid chromatography (HPLC) and capillary electrochromatography (CEC) because of their ease of preparation, high reproducibility, versatile surface chemistry and rapid mass transport. Molecularly imprinted polymers (MIPs) are synthetic materials with high specific recognition ability to template molecule. The combination of monolithic column and MIPs integrates the high efficiency of modern chromatography and the high selectivity provided by MIPs. This review focuses on the recent developments and applications of all kinds of monolithic matrix, i.e. organic polymer-based and silica-based MIP monolith in HPLC and CEC mode. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Separation of intact proteins by using polyhedral oligomeric silsesquioxane based hybrid monolithic capillary columns.

    Science.gov (United States)

    Liu, Zheyi; Ou, Junjie; Liu, Zhongshan; Liu, Jing; Lin, Hui; Wang, Fangjun; Zou, Hanfa

    2013-11-22

    High-efficient separation of intact proteins is still a huge challenge in proteome analysis of complex biological samples by using capillary columns. In this study, four POSS-based hybrid monolithic capillary columns were prepared and applied in nano-flow liquid chromatography (Nano-LC) separation of intact proteins. It was observed that the POSS-based hybrid monolithic columns exhibit high permeability, good LC separation reproducibility and column efficiency for intact protein separation. The effects of different LC separation conditions such as flow rate, gradient steepness, column length and mobile phase additives on the LC separation efficiency of the POSS-based hybrid monolithic column were systematically examined. Finally, fast LC separation of 7 proteins mixture was realized in 2.5 min by using the optimized conditions on the 100 μm i.d. POSS-based hybrid monolithic capillary column. Copyright © 2013. Published by Elsevier B.V.

  11. Monolithically integrated AlN/GaN electronics for harsh environments, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Recently, resonant-tunneling-diode (RTD) based circuits employing monolithically-integrated RTD on high electron mobility (HEMT) structures have been developed in a...

  12. Folsom Dam Outlet Works Modification Project; Simplified Three-Dimensional Stress Analysis of Monolith 12

    National Research Council Canada - National Science Library

    Matheu, Enrique E; Garner, Sharon B

    2005-01-01

    This report presents a finite-element stress analysis of monolith 12 conducted to assess any potential adverse effects caused by the proposed dimensions of the air vent near the base of the spillway pier wall...

  13. 2R-regeneration in a monolithically integrated four-section SOA-EA chip

    DEFF Research Database (Denmark)

    Vivero, Tania; Calabretta, Nicola; Tafur Monroy, Idelfonso

    2009-01-01

    Optical regeneration using a monolithically integrated chip formed by a cascade of semiconductor optical amplifiers and saturable absorbers is investigated. Static transfer functions, signal reshaping, extinction ratio enhancement, noise dynamics and device dependence on operation conditions...

  14. Improved methods of forming monolithic integrated circuits having complementary bipolar transistors

    Science.gov (United States)

    Bohannon, R. O., Jr.; Cashion, W. F.; Stehlin, R. A.

    1971-01-01

    Two new processes form complementary transistors in monolithic semiconductor circuits, require fewer steps /infusions/ than previous methods, and eliminate such problems as nonuniform h sub FE distribution, low yield, and large device formation.

  15. Monolithic three-dimensional electrochemical energy storage system on aerogel or nanotube scaffold

    Science.gov (United States)

    Farmer, Joseph C; Stadermann, Michael

    2013-11-12

    A monolithic three-dimensional electrochemical energy storage system is provided on an aerogel or nanotube scaffold. An anode, separator, cathode, and cathodic current collector are deposited on the aerogel or nanotube scaffold.

  16. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins.

    Science.gov (United States)

    Kurdi, Said El; Muaileq, Dina Abu; Alhazmi, Hassan A; Bratty, Mohammed Al; Deeb, Sami El

    2017-06-27

    HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5) and precision (RSD ≤ 0.6 %). Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  17. Comparing monolithic and fused core HPLC columns for fast chromatographic analysis of fat-soluble vitamins

    Directory of Open Access Journals (Sweden)

    Kurdi Said El

    2017-06-01

    Full Text Available HPLC stationary phases of monolithic and fused core type can be used to achieve fast chromatographic separation as an alternative to UPLC. In this study, monolithic and fused core stationary phases are compared for fast separation of four fat-soluble vitamins. Three new methods on the first and second generation monolithic silica RP-18e columns and a fused core pentafluoro-phenyl propyl column were developed. Application of three fused core columns offered comparable separations of retinyl palmitate, DL-α-tocopheryl acetate, cholecalciferol and menadione in terms of elution speed and separation efficiency. Separation was achieved in approx. 5 min with good resolution (Rs > 5 and precision (RSD ≤ 0.6 %. Monolithic columns showed, however, a higher number of theoretical plates, better precision and lower column backpressure than the fused core column. The three developed methods were successfully applied to separate and quantitate fat-soluble vitamins in commercial products.

  18. Real-time multianalyte biosensors based on interference-free multichannel monolithic quartz crystal microbalance.

    Science.gov (United States)

    Jaruwongrungsee, Kata; Waiwijit, Uraiwan; Wisitsoraat, Anurat; Sangworasil, Manas; Pintavirooj, Chuchart; Tuantranont, Adisorn

    2015-05-15

    In this work, we design, fabricate and characterize a new interference-free multichannel monolithic quartz crystal microbalance (MQCM) platform for bio-sensing applications. Firstly, interference due to thickness-shear vibration mode coupling between channels in MQCM array is effectively suppressed by interposing a polydimethylsiloxane wall between adjacent QCM electrodes on a quartz substrate to form inverted-mesa-like structure. In addition, the electrical coupling due to the electrical impedance of solution is diminished by extending the flow path between them with an extended-design flow channel. The electrical testing results show that individual QCM signal is unaffected by those of adjacent channels under liquid loading, signifying the achievement of interference-free MQCM. The MQCM is applied for multi-analyte biosensing of IgG and HSA. The anti-IgG and anti-HSA are separately immobilized on two adjacent QCM electrodes, which are subsequently blocked with BSA to avoid unspecific binding. The MQCM biosensors are tested with single- and double-analyte solutions under continuous flow of buffer. The IgG and HSA QCM sensors only show frequency shift responses to their corresponding analytes and there are very small cross frequency shifts due to remnant unspecific binding. Moreover, MQCM sensors show approximately linear frequency shift response with analyte concentration. Therefore, the developed MQCM platform is promising for real-time interference-free label-free detection and quantification of multiple bio-analytes. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Front-end receiver electronics for high-frequency monolithic CMUT-on-CMOS imaging arrays.

    Science.gov (United States)

    Gurun, Gokce; Hasler, Paul; Degertekin, F

    2011-08-01

    This paper describes the design of CMOS receiver electronics for monolithic integration with capacitive micromachined ultrasonic transducer (CMUT) arrays for highfrequency intravascular ultrasound imaging. A custom 8-inch (20-cm) wafer is fabricated in a 0.35-μm two-poly, four-metal CMOS process and then CMUT arrays are built on top of the application specific integrated circuits (ASICs) on the wafer. We discuss advantages of the single-chip CMUT-on-CMOS approach in terms of receive sensitivity and SNR. Low-noise and high-gain design of a transimpedance amplifier (TIA) optimized for a forward-looking volumetric-imaging CMUT array element is discussed as a challenging design example. Amplifier gain, bandwidth, dynamic range, and power consumption trade-offs are discussed in detail. With minimized parasitics provided by the CMUT-on-CMOS approach, the optimized TIA design achieves a 90 fA/√Hz input-referred current noise, which is less than the thermal-mechanical noise of the CMUT element. We show successful system operation with a pulseecho measurement. Transducer-noise-dominated detection in immersion is also demonstrated through output noise spectrum measurement of the integrated system at different CMUT bias voltages. A noise figure of 1.8 dB is obtained in the designed CMUT bandwidth of 10 to 20 MHz.

  20. Frontend Receiver Electronics for High Frequency Monolithic CMUT-on-CMOS Imaging Arrays

    Science.gov (United States)

    Gurun, Gokce; Hasler, Paul; Degertekin, F. Levent

    2012-01-01

    This paper describes the design of CMOS receiver electronics for monolithic integration with capacitive micromachined ultrasonic transducer (CMUT) arrays for high-frequency intravascular ultrasound imaging. A custom 8-inch wafer is fabricated in a 0.35 μm two-poly, four-metal CMOS process and then CMUT arrays are built on top of the application specific integrated circuits (ASICs) on the wafer. We discuss advantages of the single-chip CMUT-on-CMOS approach in terms of receive sensitivity and SNR. Low-noise and high-gain design of a transimpedance amplifier (TIA) optimized for a forward-looking volumetric-imaging CMUT array element is discussed as a challenging design example. Amplifier gain, bandwidth, dynamic range and power consumption trade-offs are discussed in detail. With minimized parasitics provided by the CMUT-on-CMOS approach, the optimized TIA design achieves a 90 fA/√Hz input referred current noise, which is less than the thermal-mechanical noise of the CMUT element. We show successful system operation with a pulse-echo measurement. Transducer noise-dominated detection in immersion is also demonstrated through output noise spectrum measurement of the integrated system at different CMUT bias voltages. A noise figure of 1.8 dB is obtained in the designed CMUT bandwidth of 10 MHz to 20 MHz. PMID:21859585

  1. ZnO on nickel RF micromechanical resonators for monolithic wireless communication applications

    Science.gov (United States)

    Wei, Mian; Avila, Adrian; Rivera, Ivan; Baghelani, Masoud; Wang, Jing

    2017-05-01

    On-chip integrability of high-Q RF passives alongside CMOS transistors is crucial for the implementation of monolithic radio transceivers. One of the most significant bottlenecks in back-end-of-line (BEoL) integration of MEMS devices on CMOS processed wafers is their relatively low thermal budget, which is less than that required for typical MEMS material deposition processes. This paper investigates electroplated nickel as a structural material for piezoelectrically-transduced resonators to demonstrate ZnO-on-nickel resonators with a CMOS-compatible low temperature process for the first time. Aside from the obvious manufacturing cost benefit, electroplated nickel is a reasonable substitute for polycrystalline or single crystal silicon and thin-film microcrystalline diamond device layers, while realizing decent acoustic velocity and moderate Q. Electroplated nickel has been already adopted by MEMSCAP, a multi-user MEMS process foundry, in its MetalMUMPs process. Furthermore, it is observed that a localized annealing process through Joule heating can be exploited to significantly improve the effective mechanical quality factor for the ZnO-on-nickel resonators, which is still lower than the reported AlN resonators. This work demonstrates ZnO-on-nickel piezoelectrically-actuated MEMS resonators and resonator arrays by using an IC compatible low temperature process. There is room for performance improvement by lowering the acoustic energy losses in the ZnO and nickel layers.

  2. Tailoring the graphene/silicon carbide interface for monolithic wafer-scale electronics.

    Science.gov (United States)

    Hertel, S; Waldmann, D; Jobst, J; Albert, A; Albrecht, M; Reshanov, S; Schöner, A; Krieger, M; Weber, H B

    2012-07-17

    Graphene is an outstanding electronic material, predicted to have a role in post-silicon electronics. However, owing to the absence of an electronic bandgap, graphene switching devices with high on/off ratio are still lacking. Here in the search for a comprehensive concept for wafer-scale graphene electronics, we present a monolithic transistor that uses the entire material system epitaxial graphene on silicon carbide (0001). This system consists of the graphene layer with its vanishing energy gap, the underlying semiconductor and their common interface. The graphene/semiconductor interfaces are tailor-made for ohmic as well as for Schottky contacts side-by-side on the same chip. We demonstrate normally on and normally off operation of a single transistor with on/off ratios exceeding 10(4) and no damping at megahertz frequencies. In its simplest realization, the fabrication process requires only one lithography step to build transistors, diodes, resistors and eventually integrated circuits without the need of metallic interconnects.

  3. Kilo-scale droplet generation in three-dimensional monolithic elastomer device (3D MED).

    Science.gov (United States)

    Jeong, Heon-Ho; Yelleswarapu, Venkata R; Yadavali, Sagar; Issadore, David; Lee, Daeyeon

    2015-12-07

    Droplet-based microfluidics has led to transformational new approaches in diverse areas including materials synthesis and high-throughput biological assays. However, the translation of droplet microfluidics technology into commercial applications requires scale-up of droplet generation from the laboratory (1 L h(-1)) scale. To address this challenge, we develop a three-dimensional monolithic elastomer device (3D MED) for mass production of monodisperse emulsion droplets. Using double-sided imprinting, 3D microchannels are formed in a single elastomer piece that has 1000 parallel flow focusing generators (k-FFGs). Compared to previous work that parallelizes droplet generation, the 3D MED eliminates the needs for alignment and bonding of multiple pieces and thus makes it possible to achieve the high flow rates and pressure necessary for the kilo-scale generation of droplets. Using this approach, we demonstrate mass production of water-in-oil (W/O) emulsion droplets at production rates as high as 1.5 L h(-1) (>30 billion 45 μm diameter droplets per hour), with a coefficient of variation of droplet diameter of only 6.6%. Because of the simplicity, robustness, and manufacturability of our 3D MED architecture, it is well suited to bridge the gap between the continuously growing library of promising microfluidic technologies to generate microparticles that have been demonstrated in laboratory settings and their successful application in industry.

  4. 3D graphene foam as a monolithic and macroporous carbon electrode for electrochemical sensing.

    Science.gov (United States)

    Dong, Xiaochen; Wang, Xuewan; Wang, Lianhui; Song, Hao; Zhang, Hua; Huang, Wei; Chen, Peng

    2012-06-27

    Graphene, a single-atom-thick monolayer of sp(2) carbon atoms perfectly arranged in a honeycomb lattice, is an emerging sensing material because of its extraordinary properties, such as exceptionally high specific surface area, electrical conductivity, and electrochemical potential window. In this study, we demonstrate that three-dimensional (3D), macroporous, highly conductive, and monolithic graphene foam synthesized by chemical vapor deposition represents a novel architecture for electrochemical electrodes. Being employed as an electrochemical sensor for detection of dopamine, 3D graphene electrode exhibits remarkable sensitivity (619.6 μA mM(-1) cm(-2)) and lower detection limit (25 nM at a signal-to-noise ratio of 5.6), with linear response up to ∼25 μM. And the oxidation peak of dopamine can be easily distinguished from that of uric acid - a common interferent to dopamine detection. We envision that the graphene foam provides a promising platform for the development of electrochemical sensors as well as other applications, such as energy storage and conversion.

  5. Advancing the technology of monolithic CMOS detectors for use as x-ray imaging spectrometers

    Science.gov (United States)

    Kenter, Almus; Kraft, Ralph; Gauron, Thomas; Amato, Stephen

    2017-08-01

    The Smithsonian Astrophysical Observatory (SAO) in collaboration with SRI/Sarnoff has been engaged in a multi year effort to advance the technology of monolithic back-thinned CMOS detectors for use as X-ray imaging spectrometers. The long term goal of this campaign is to produce X-ray Active Pixel Sensor (APS) detectors with Fano limited performance over the 0.1-10keV band while incorporating the many benefits of CMOS technology. These benefits include: low power consumption, radiation "hardness", high levels of integration, and very high read rates. Such devices would be ideal for candidate post 2020 decadal missions such as LYNX and for smaller more immediate applications such as CubeX. Devices from a recent fabrication have been back-thinned, packaged and tested for soft X-ray response. These devices have 16μm pitch, 6 Transistor Pinned Photo Diode (6TPPD) pixels with ˜135μV/electron sensitivity and a highly parallel signal chain. These new detectors are fabricated on 10μm epitaxial silicon and have a 1k by 1k format. We present details of our camera design and device performance with particular emphasis on those aspects of interest to single photon counting X-ray astronomy. These features include read noise, X-ray spectral response and quantum efficiency.

  6. The fabrication and modification of capillary polymer monoliths for the separation of small ions

    OpenAIRE

    Moyna, Aine

    2012-01-01

    The fabrication and modification of polymer monoliths, in capillary formats, for the separation of small ions is presented. The separation of small ions using polymer monoliths has limitations and this work aims to investigate increasing the ion exchange capacity using photo-grafting techniques. Chapter 1.0 includes a comprehensive review on the use of capillary ion chromatography including advancements made in capillary instrumentation, stationary phases and detection devices. This chapter a...

  7. Influence of the preparation design and artificial aging on the fracture resistance of monolithic zirconia crowns

    OpenAIRE

    Mitov, Gergo; Anastassova-Yoshida, Yana; Nothdurft, Frank Phillip; von See, Constantin; Pospiech, Peter

    2016-01-01

    PURPOSE The aim of this study was to evaluate the fracture resistance and fracture behavior of monolithic zirconia crowns in accordance with the preparation design and aging simulation method. MATERIALS AND METHODS An upper first molar was prepared sequentially with three different preparation designs: shoulderless preparation, 0.4 mm chamfer and 0.8 mm chamfer preparation. For each preparation design, 30 monolithic zirconia crowns were fabricated. After cementation on Cr-Co alloy dies, the f...

  8. THE CHANGE IN DEFORMATION CHARACTERISTICS OF CONCRETE MONOLITHIC HIGH-RISE BUILDINGS

    Directory of Open Access Journals (Sweden)

    V. V. Punahin

    2009-03-01

    Full Text Available In the article results of studies of deformation features of concrete on actuate cement for monolithic high-altitude buildings are presented. It is shown that in construction of the high-altitude monolithic buildings in a summer period of a year one should take into account the character of changing the concrete elasticity and plasticity in time, which differs from the same indices for the concrete of normal hardening.

  9. Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type

    OpenAIRE

    Ha, Seung-Ryong

    2015-01-01

    PURPOSE The objective of this study was to evaluate the influence of various cement types on the stress distribution in monolithic zirconia crowns under maximum bite force using the finite element analysis. MATERIALS AND METHODS The models of the prepared #46 crown (deep chamfer margin) were scanned and solid models composed of the monolithic zirconia crown, cement layer, and prepared tooth were produced using the computer-aided design technology and were subsequently translated into 3-dimens...

  10. The application of a monolithic triphenylphosphine reagent for conducting Ramirez gem-dibromoolefination reactions in flow.

    Science.gov (United States)

    Roper, Kimberley A; Berry, Malcolm B; Ley, Steven V

    2013-01-01

    The application of a monolithic form of triphenylphosphine to the Ramirez gem-dibromoolefination reaction using flow chemistry techniques is reported. A variety of gem-dibromides were synthesised in high purity and excellent yield following only removal of solvent and no further off-line purification. It is also possible to perform the Appel reaction using the same monolith and the relationship between the mechanisms of the two reactions is discussed.

  11. The application of a monolithic triphenylphosphine reagent for conducting Ramirez gem-dibromoolefination reactions in flow

    Directory of Open Access Journals (Sweden)

    Kimberley A. Roper

    2013-09-01

    Full Text Available The application of a monolithic form of triphenylphosphine to the Ramirez gem-dibromoolefination reaction using flow chemistry techniques is reported. A variety of gem-dibromides were synthesised in high purity and excellent yield following only removal of solvent and no further off-line purification. It is also possible to perform the Appel reaction using the same monolith and the relationship between the mechanisms of the two reactions is discussed.

  12. Rapid Fabrication of Low-Density Porous Tin Monolith via Hydrogen Bulb Dynamics Templates

    Science.gov (United States)

    Ren, Hongbo; Zhu, Jiayi; Bi, Yutie; Xu, Yewei; Zhang, Lin; Wang, Ni

    Low-density porous tin monolith with the pteridophyta leaf-like structure was fast fabricated by a facile route via the electrochemical deposition process via hydrogen bulb dynamics templates within less than 1min. The samples were characterized by scanning electron microscope, X-ray diffraction and so on. The results indicated that the deposited tin porous structure could be easily controlled to form film or monolith by adjusting the tin precursor concentration and surfactant content.

  13. Modeling Thermal and Stress Behavior of the Fuel-clad Interface in Monolithic Fuel Mini-plates

    International Nuclear Information System (INIS)

    Miller, Gregory K.; Medvedev, Pavel G.; Burkes, Douglas E.; Wachs, Daniel M.

    2010-01-01

    As part of the Global Threat Reduction Initiative, a fuel development and qualification program is in process with the objective of qualifying very high density low enriched uranium fuel that will enable the conversion of high performance research reactors with operational requirements beyond those supported with currently available low enriched uranium fuels. The high density of the fuel is achieved by replacing the fuel meat with a single monolithic low enriched uranium-molybdenum fuel foil. Doing so creates differences in the mechanical and structural characteristics of the fuel plate because of the planar interface created by the fuel foil and cladding. Furthermore, the monolithic fuel meat will dominate the structural properties of the fuel plate rather than the aluminum matrix, which is characteristic of dispersion fuel types. Understanding the integrity and behavior of the fuel-clad interface during irradiation is of great importance for qualification of the new fuel, but can be somewhat challenging to determine with a single technique. Efforts aimed at addressing this problem are underway within the fuel development and qualification program, comprised of modeling, as-fabricated plate characterization, and post-irradiation examination. An initial finite element analysis model has been developed to investigate worst-case scenarios for the basic monolithic fuel plate structure, using typical mini-plate irradiation conditions in the Advanced Test Reactor. Initial analysis shows that the stress normal to the fuel-clad interface dominates during irradiation, and that the presence of small, rounded delaminations at the interface is not of great concern. However, larger and/or fuel-clad delaminations with sharp corners can create areas of concern, as maximum principal cladding stress, strain, displacement, and peak fuel temperature are all significantly increased. Furthermore, stresses resulting from temperature gradients that cause the plate to bow or buckle in

  14. Robocast Pb(Zr0.95Ti0.05)O3 Ceramic Monoliths and Composites

    International Nuclear Information System (INIS)

    Tuttle, Bruce A.; Smay, James E.; Cesarano, Joseph III; Voigt, James A.; Scofield, Timothy W.; Olson, Walter R.; Lewis, J.A.

    2000-01-01

    Robocasting, a computer controlled slurry deposition technique, was used to fabricate ceramic monoliths and composites of chemically prepared Pb(Zr 0.95 Ti 0.05 )O 3 (PZT 95/5) ceramics. Densities and electrical properties of the robocast samples were equivalent to those obtained for cold isostatically pressed (CIP) parts formed at 200 MPa. Robocast composites consisting of alternate layers of the following sintered densities: (93.9%--96.1%--93.9%), were fabricated using different levels of organic pore former additions. Modification from a single to a multiple material deposition robocaster was essential to the fabrication of composites that could withstand repeated cycles of saturated polarization switching under 30 kV/cm fields. Further, these composites withstood 500 MPa hydrostatic pressure induced poled ferroelectric (FE) to antiferroelectric (AFE) phase transformation during which strain differences on the order of 0.8% occurred between composite elements

  15. Study of the spectrometric performances of monolithic CdZnTe / CdTe gamma ray detectors

    International Nuclear Information System (INIS)

    Gros d'Aillon, E.

    2005-11-01

    Pixelated monolithic CdTe/CdZnTe semiconductor gamma ray detectors are brought to replace scintillation detectors for medical applications, notably for single photon emission computed tomography (SPECT). In addition to compactness, they present better spectrometric performances: energy resolution, detection efficiency, and spatial resolution. Moreover, the photons depth of interaction in the crystal can be measured. This work aimed in studying experimentally and by simulation the correlations between anodes pitch, material physic properties (resistivity and electron transport properties), and detectors spectrometric performances. We have compared several methods of measuring the photon interaction depth, and have obtained an energy resolution ranging from 1.7% to 7% at 122 keV, according to material, for 5 mm thick detectors. Charge sharing between adjacent anodes has been studied and a measured data processing is proposed. (author)

  16. A Butyl Methacrylate Monolithic Column Prepared In-Situ on a Microfluidic Chip and its Applications

    Directory of Open Access Journals (Sweden)

    Qiang Cao

    2009-05-01

    Full Text Available A butyl methacrylate (BMA monolithic column was polymerized in-situ with UV irradiation in an ultraviolet transparent PDMS micro-channel on a homemade micro-fluidic chip. Under the optimized conditions and using a typical polymerization mixture consisting of 75% porogenic solvents and 25% monomers, the BMA monolithic column was obtained as expected. The BET surface area ratio of the BMA monolithic column was 366 m2·g-1. The corresponding SEM images showed that the monolithic column material polymerized in a glass channel was composed of uniform pores and spherical particles with diameters ranging from 3 to 5 μm. The promethazine–luminal–potassium ferricyanide chemiluminescence system was selected for testing the capability of the column. A flow injection analytical technique–chemiluminescence (FIA–CL system on the microfluidic chip with a BMA monolithic column pretreatment unit was established to determine promethazine. Trace promethazine was enriched by the BMA monolithic column, with more than a 10-fold average enrichment ratio. The proposed method has a linear response concentration range of 1.0×10-8 - 1.0×10-6g·mL-1 and the detection limit was 1.6×10-9g·mL-1.

  17. A butyl methacrylate monolithic column prepared in-situ on a microfluidic chip and its applications.

    Science.gov (United States)

    Xu, Yi; Zhang, Wenpin; Zeng, Ping; Cao, Qiang

    2009-01-01

    A butyl methacrylate (BMA) monolithic column was polymerized in-situ with UV irradiation in an ultraviolet transparent PDMS micro-channel on a homemade micro-fluidic chip. Under the optimized conditions and using a typical polymerization mixture consisting of 75% porogenic solvents and 25% monomers, the BMA monolithic column was obtained as expected. The BET surface area ratio of the BMA monolithic column was 366 m(2)·g(-1). The corresponding SEM images showed that the monolithic column material polymerized in a glass channel was composed of uniform pores and spherical particles with diameters ranging from 3 to 5 μm. The promethazine-luminal-potassium ferricyanide chemiluminescence system was selected for testing the capability of the column. A flow injection analytical technique-chemiluminescence (FIA-CL) system on the microfluidic chip with a BMA monolithic column pretreatment unit was established to determine promethazine. Trace promethazine was enriched by the BMA monolithic column, with more than a 10-fold average enrichment ratio. The proposed method has a linear response concentration range of 1.0×10(-8) - 1.0×10(-6)g·mL(-1) and the detection limit was 1.6×10(-9)g·mL(-1).

  18. Preparation and characterization of alkyl methacrylate-based monolithic columns for capillary gas chromatography applications.

    Science.gov (United States)

    Yusuf, Kareem; Aqel, Ahmad; A L Othman, Zeid; Badjah-Hadj-Ahmed, Ahmed Yacine

    2013-08-02

    Gas chromatography (GC) is considered the least common application of both polymer and silica-based monolithic columns. This study describes the fabrication of alkyl methacrylate monolithic materials for use as stationary phases in capillary gas chromatography. Following the deactivation of the capillary surface with 3-(trimethoxysilyl)propyl methacrylate (TMSM), the monoliths were formed by the co-polymerization of either hexyl methacrylate (HMA) or lauryl methacrylate (LMA) with different percentage of ethylene glycol dimethacrylate (EDMA) in presence of an initiator (azobisisobutyronitrile, AIBN) and a mixture of porogens include 1-propanol, 1,4-butanediol and water. The monoliths were prepared in 500mm length capillaries possessing inner diameters of 250μm. The efficiencies of the monolithic columns for low molecular weight compounds significantly improved as the percentage of crosslinker was increased, because of the greater proportion of pores less than 50nm. The columns containing lower percentages of crosslinker were able to rapidly separate a series of 8 alkane members in 0.7min, but the separation was less efficient for the light alkanes. Columns prepared with the lauryl methacrylate monomer yielded a different morphology for the monolith-interconnected channels. The channels were more branched, which increased the separation time, and unlike the other columns, allowed for temperature programming. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. [Preparation of divinylbenzene polymer monolithic columns and their applications in gas chromatography].

    Science.gov (United States)

    Tian, Hongxu; Li, Yun; Chen, Jiping

    2010-11-01

    The preparation of divinylbenzene polymer monolithic columns and their applications in gas chromatography (GC) are discussed. Based on liquid chromatographic (LC) monolithic columns, the high-permeable monolithic columns can be applied in GC through changing the ratio of toluene and dodecanol. It is shown that the monolithic columns possess fastness configuration and good mechanical intensity via the bonding of 3-(trimethoxysilyl) propyl methacrylate (TMP) to the capillary wall and the polymerization of the crosslinker itself. Compared with a commercial porous layer open tube (PLOT) column and a PEG-20M column, the monolithic columns demonstrate good performance in the analysis of low carbon alcohols in water, the analysis of mixed solvents and the standard liquor sample. In the mixed solvents, the peak symmetries of alcohols, ketones, esters and aromatics precede those on the PLOT column. The separation of methanol, acetaldehyde and ethyl acetate in the standard liquor sample on the monolithic column is much more convenient than that on PEG-20M columns.

  20. Rapid recovery of DNA from agarose gel slices by coupling electroelution with monolithic SPE.

    Science.gov (United States)

    Yu, Shengbing; Yang, Shuixian; Zhou, Ping; Zhou, Ke; Wang, Jing; Chen, Xiangdong

    2009-06-01

    An amino silica monolithic column prepared by in situ polymerization of tetraethoxysilane and N-(beta-aminoethyl)-gamma-aminopropyltriethoxysilane was firstly applied to recover DNA from agarose gel slices by coupling electroelution with monolithic SPE. DNA was electroeluted from the agarose gel slices onto the amino silica monolithic column. The DNA adsorbed on this monolithic column was then recovered using sodium phosphate solution at pH 10. The whole recovery procedure could be completed within 10 min because the use of amino silica monolithic column accelerated the DNA capture and facilitated the DNA release. Electroelution conditions, such as buffer pH, buffer concentration and applied voltage, were online optimized. The average yield for herring sperm DNA, pBR 322 DNA and lambda DNA recovered from 1.0% w/v agarose gel slices were 55+/-4, 50+/-6 and 42+/-7% (n=3), respectively. The polymerase chain reaction performance of pGM plasmid recovered from agarose gel slices demonstrated that the method could provide high-quality DNA for downstream processes. The combination of electroelution with monolithic SPE allows a rapid, simple and efficient DNA recovery method. This technique is especially useful for applications that need to purify small starting amounts of DNA.

  1. Fracture Strength of Aged Monolithic and Bilayer Zirconia-Based Crowns.

    Science.gov (United States)

    Lameira, Deborah Pacheco; Buarque e Silva, Wilkens Aurélio; Andrade e Silva, Frederico; De Souza, Grace M

    2015-01-01

    The purpose of this study was to evaluate the effect of design and surface finishing on fracture strength of yttria-tetragonal zirconia polycrystal (Y-TZP) crowns in monolithic (1.5 mm thickness) and bilayer (0.8 mm zirconia coping and 0.7 mm porcelain veneer) configuration after artificial aging. Bovine incisors received crown preparation and Y-TZP crowns were manufactured using CAD/CAM technique, according to the following groups (n = 10): Polished monolithic zirconia crowns (PM); Glazed monolithic zirconia crowns (GM); Bi-layer crowns (BL). Crowns were cemented with resin cement, submitted to artificial aging in a chewing simulator (2.5 million cycles/80 N/artificial saliva/37 °C), and tested for fracture strength. Two remaining crowns referring to PM and GM groups were submitted to a chemical composition analysis to measure the level of yttrium after aging. One-way ANOVA and Tukey's test (P = .05) indicated that monolithic zirconia crowns presented similar fracture strength (PM = 3476.2 N ± 791.7; GM = 3561.5 N ± 991.6), which was higher than bilayer crowns (2060.4 N ± 810.6). There was no difference in the yttrium content among the three surfaces evaluated in the monolithic crowns. Thus, monolithic zirconia crowns present higher fracture strength than bilayer veneered zirconia after artificial aging and surface finishing does not affect their fracture strength.

  2. Behavior of macroporous vinyl silica and silica monolithic columns in high pressure gas chromatography.

    Science.gov (United States)

    Maniquet, Adrien; Bruyer, Nicolas; Raffin, Guy; Baco-Antionali, Franck; Demesmay, Claire; Dugas, Vincent; Randon, Jérôme

    2017-06-30

    80% vinyltrimethoxysilane-based hybrid silica monoliths (80-VTMS), which have been initially developed for separation in reversed-phase liquid chromatography, have been investigated in high pressure gas chromatography separations (carrier gas pressure up to 60bar) and compared to silica monolithic columns. The behavior of both silica and 80-VTMS monolithic columns was investigated using helium, nitrogen and carbon dioxide as carrier gas. The efficiency of 80-VTMS monolithic columns was shown to vary differently than silica monolithic columns according to the temperature and the carrier gas used. Carrier gas nature was a significant parameter on the retention for both silica and vinyl columns in relation to its adsorption onto the stationary phase in such high pressure conditions. The comparison of retention and selectivity between 80-VTMS monoliths and silica was performed under helium using the logarithm of the retention factor according to the number of carbon atoms combined to Kovats indexes. The very good performances of these columns were demonstrated, allowing the separation of 8 compounds in less than 1min. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. Preparation of porous polymer monoliths featuring enhanced surface coverage with gold nanoparticles

    KAUST Repository

    Lv, Yongqin

    2012-10-01

    A new approach to the preparation of porous polymer monoliths with enhanced coverage of pore surface with gold nanoparticles has been developed. First, a generic poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith was reacted with cystamine followed by the cleavage of its disulfide bonds with tris(2-carboxylethyl)phosphine, which liberated the desired thiol groups. Dispersions of gold nanoparticles with sizes varying from 5 to 40. nm were then pumped through the functionalized monoliths. The materials were then analyzed using both energy dispersive X-ray spectroscopy and thermogravimetric analysis. We found that the quantity of attached gold was dependent on the size of nanoparticles, with the maximum attachment of more than 60. wt% being achieved with 40. nm nanoparticles. Scanning electron micrographs of the cross sections of all the monoliths revealed the formation of a non-aggregated, homogenous monolayer of nanoparticles. The surface of the bound gold was functionalized with 1-octanethiol and 1-octadecanethiol, and these monolithic columns were used successfully for the separations of proteins in reversed phase mode. The best separations were obtained using monoliths modified with 15, 20, and 30. nm nanoparticles since these sizes produced the most dense coverage of pore surface with gold. © 2012 Elsevier B.V.

  4. Applications of monolithic columns in liquid chromatography-based clinical chemistry assays.

    Science.gov (United States)

    Bunch, Dustin R; Wang, Sihe

    2011-08-01

    Monolithic columns have slowly been applied to HPLC methods for clinical chemistry testing in the last 10 years. The application areas include therapeutic drug monitoring, drugs of abuse, vitamins, porphyrins, and steroids. In comparison with conventional particulate columns, the monolithic columns may offer shorter chromatography time, more robustness, and better resolution for certain analytes. The potential drawback of large mobile phase consumption may be improved with smaller id columns, which are currently on the market. Methods covered in this review are those searchable in PubMed up to December 2010. This review highlights the emergence of monolithic column technology in HPLC methods used for clinical chemistry testing. The goals of this review are threefold: (i) To identify the areas of clinical chemistry that analytical monolithic columns have been used in HPLC methods. (ii) To demonstrate the application of analytical monolithic columns in HPLC methods using different detection systems. (iii) To discuss the advantages and limitations of the monolithic columns compared with particulate columns in the clinical chemistry applications. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. A Butyl Methacrylate Monolithic Column Prepared In-Situ on a Microfluidic Chip and its Applications

    Science.gov (United States)

    Xu, Yi; Zhang, Wenpin; Zeng, Ping; Cao, Qiang

    2009-01-01

    A butyl methacrylate (BMA) monolithic column was polymerized in-situ with UV irradiation in an ultraviolet transparent PDMS micro-channel on a homemade micro-fluidic chip. Under the optimized conditions and using a typical polymerization mixture consisting of 75% porogenic solvents and 25% monomers, the BMA monolithic column was obtained as expected. The BET surface area ratio of the BMA monolithic column was 366 m2·g-1. The corresponding SEM images showed that the monolithic column material polymerized in a glass channel was composed of uniform pores and spherical particles with diameters ranging from 3 to 5 μm. The promethazine–luminal–potassium ferricyanide chemiluminescence system was selected for testing the capability of the column. A flow injection analytical technique–chemiluminescence (FIA–CL) system on the microfluidic chip with a BMA monolithic column pretreatment unit was established to determine promethazine. Trace promethazine was enriched by the BMA monolithic column, with more than a 10-fold average enrichment ratio. The proposed method has a linear response concentration range of 1.0×10-8 - 1.0×10-6g·mL-1 and the detection limit was 1.6×10-9g·mL-1. PMID:22412320

  6. Design of catalytic monoliths for closed-cycle carbon dioxide lasers

    Science.gov (United States)

    Herz, R. K.; Guinn, K.; Goldblum, S.; Noskowski, E.

    1989-01-01

    Pulsed carbon dioxide (CO2) lasers have many applications in aeronautics, space research, weather monitoring and other areas. Full exploitation of the potential of these lasers in hampered by the dissociation of CO2 that occurs during laser operation. The development of closed-cycle CO2 lasers requires active CO-O2 recombination (CO oxidation) catalyst and design methods for implementation of catalysts in CO2 laser systems. A monolith catalyst section model and associated design computer program, LASCAT, are presented to assist in the design of a monolith catalyst section of a closed cycle CO2 laser system. Using LASCAT,the designer is able to specify a number of system parameters and determine the monolith section performance. Trade-offs between the catalyst activity, catalyst dimensions, monolith dimensions, pressure drop, O2 conversion, and other variables can be explored and adjusted to meet system design specifications. An introduction describes a typical closed-cycle CO2 system, and indicates some advantages of a closed cycle laser system over an open cycle system and some advantages of monolith support over other types of supports. The development and use of a monolith catalyst model is presented. The results of a design study and a discussion of general design rules are given.

  7. Ionic liquid-regenerated macroporous cellulose monolith: Fabrication, characterization and its protein chromatography.

    Science.gov (United States)

    Du, Kaifeng

    2017-04-21

    Macroporous cellulose monolith as chromatographic support was successfully fabricated from an ionic liquid dissolved cellulose solution by an emulsification method and followed by the cross-linking reaction and DEAE modification. With the physical characterization, the cellulose monolith featured by both the interconnected macropores in range of 0.5-2.5μm and the diffusion pores centered at about 10nm. Given the bimodal pore system, the monolith possessed the specific surface area of 36.4m 2 g -1 and the column permeability of about 7.45×10 -14 m 2 . After the DEAE modification, the anion cellulose monolith was evaluated for its chromatography performances. It demonstrated that the static and dynamic adsorption capacity of BSA reached about 66.7mgmL -1 and 43.9mgmL -1 at 10% breakthrough point, respectively. The results were comparable to other chromatographic adsorbent. In addition, the proteins mixture with different pI was well separated at high flow velocity (611.0cmh -1 ) and high protein recovery (over 97%), proving the macroporous cellulose monolith had excellent separation performance. In this way, the prepared cellulose monolith with bimodal pores system is expected for the potential application in high-speed chromatography. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. You Can't Unscramble an Egg: Population Genetic Structure of Oncorhynchus mykiss in the California Central Valley Inferred from Combined Microsatellite and Single Nucleotide Polymorphism Data

    OpenAIRE

    Pearse, Devon E.; Garza, John Carlos

    2015-01-01

    doi: http://dx.doi.org/10.15447/sfews.2015v13iss4art3 Steelhead/rainbow trout (Oncorhynchus mykiss) are found in all of the major tributaries of the Sacramento and San Joaquin rivers, which flow through California’s Central Valley and enter the ocean through San Francisco Bay and the Golden Gate. This river system is heavily affected by water development, agriculture, and invasive species, and salmon and trout hatchery propagation has been occurring for over 100 years. We c...

  9. Investigation of bi-enzymatic reactor based on hybrid monolith with nanoparticles embedded and its proteolytic characteristics.

    Science.gov (United States)

    Shangguan, Lulu; Zhang, Lingyi; Xiong, Zhichao; Ren, Jun; Zhang, Runsheng; Gao, Fangyuan; Zhang, Weibing

    2015-04-03

    The bottom-up strategy of proteomic profiling study based on mass spectrometer (MS) has drawn high attention. However, conventional solution-based digestion could not satisfy the demands of highly efficient and complete high throughput proteolysis of complex samples. We proposed a novel bi-enzymatic reactor by immobilizing two different enzymes (trypsin/chymotrypsin) onto a mixed support of hybrid organic-inorganic monolith with SBA-15 nanoparticles embedded. Typsin and chymotrypsin were crossly immobilized onto the mixed support by covalent bonding onto the monolith with glutaraldehyde as bridge reagent and chelation via copper ion onto the nanoparticles, respectively. Compared with single enzymatic reactors, the bi-enzymatic reactor improved the overall functional analysis of membrane proteins of rat liver by doubling the number of identified peptides (from 1184/1010 with trypsin/chymotrypsin enzymatic reactors to 2891 with bi-enzymatic reactor), which led to more proteins identified with deep coverage (from 452/336 to 620); the efficiency of the bi-enzymatic reactor is also better than that of solution-based tandem digestion, greatly shorting the digestion time from 24h to 50s. Moreover, more transmembrane proteins were identified by bi-enzymatic reactor (106) compared with solution-based tandem digestion (95) with the same two enzymes and enzymatic reactors with single enzyme immobilized (75 with trypsin and 66 with chymotrypsin). The proteolytic characteristics of the bi-enzymatic reactors were evaluated by applying them to digestion of rat liver proteins. The reactors showed good digestion capability for proteins with different hydrophobicity and molecular weight. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. FIBROUS MONOLITH WEAR RESISTANT COMPONENTS FOR THE MINING INDUSTRY

    Energy Technology Data Exchange (ETDEWEB)

    Mark J. Rigali

    2001-10-01

    Published mechanical and thermal properties data on a variety of materials was gathered, with focus on materials that have potential with respect to developing wear resistant and damage tolerant composite for mining industry applications. Preliminary core materials of interest include but are not limited to: Diamond, Tungsten Carbide and Cemented Tungsten Carbides, Carbides of Boron, Silicon, Titanium and Aluminum, Diboride of Titanium and Aluminum, Nitrides of Aluminum, Silicon, Titanium, and Boron, Aluminum Oxide, Tungsten, Titanium, Iron, Cobalt and Metal Alloys. Preliminary boundary materials of interest include but are not limited to: W metal, WC-Co, W-Co, WFeNi, and Mo metal and alloys. Several FM test coupons were fabricated with various compositions using the above listed materials. These coupons were consolidated to varying degrees by uniaxial hot pressing, then cut and ground to expose the FM cell structure. One promising system, WC-Co core and WFeNi boundary, was consolidated to 97% of theoretical density, and demonstrates excellent hardness. Data on standard mechanical tests was gathered, and tests will begin on the consolidated test coupons during the upcoming reporting period. The program statements of work for ACR Inc. and its subcontractors, as well as the final contract negotiations, were finalized during the current reporting period. The program start date was February 22nd, 2001. In addition to the current subcontractors, Kennametal Inc., a major manufacturer of cutting tools and wear resistant tooling for the mining industry, expressed considerable interest in ACR's Fibrous Monolith composites for both machine and mining applications. At the request of Kennametal, ARC Inc fabricated and delivered several Fibrous Monolith coupons and components for testing and evaluation in the mining and machine tool applications. Additional samples of Diamond/Tungsten Carbide-6%Cobalt Fibrous Monolith were fabricated and delivered for testing Kennametal

  11. Fabrication of porous zeolite/chitosan monoliths and their applications for drug release and metal ions adsorption.

    Science.gov (United States)

    Zhang, Yongli; Yan, Weiwei; Sun, Zhiming; Pan, Cheng; Mi, Xue; Zhao, Gang; Gao, Jianping

    2015-03-06

    Ordered porous zeolite/chitosan (Zel/Chi) monoliths were prepared by a unidirectional freeze-drying method, and their properties and structures were characterized by various instrumental methods. The metal ion adsorption and the drug release performance of the porous Zel/Chi monoliths were also studied. The release rate of cefalexin from drug-loaded Zel/Chi monoliths depended on the composition and porous structure of the monoliths. The metal ion adsorption capacity of the Zel/Chi monoliths was related to the concentration of the metal ions, the adsorption time and the Zel/Chi ratio. An experimentally maximum adsorption of 89 mg/g was achieved for Cu(2+) ions. The Zel/Chi monoliths with adsorbed Cu(2+) ions effectively catalyzed the reduction of 4-nitrophenol to 4-aminophenol and had good recyclability. They were easily recovered by simply removing them from the reaction system and rinsing them with water. Copyright © 2014. Published by Elsevier Ltd.

  12. Superficial siderosis of the central nervous system induced by a single-episode of traumatic subarachnoid hemorrhage: a study using MRI-enhanced gradient echo T2 star-weighted angiography.

    Directory of Open Access Journals (Sweden)

    Hongwei Zhao

    Full Text Available The purpose of this study was to examine whether a single episode of traumatic subarachnoid hemorrhage (tSAH could cause superficial siderosis of the central nervous system (SS-CNS.This study was approved by the local ethics committee. Thirty-two patients with a history of a single episode of tSAH were enrolled in the study. An episode of tSAH was confirmed in patients based on a CT scan or a lumbar puncture, and a follow-up examination was conducted at least six weeks after the brain trauma. A follow-up MRI examination was performed, using enhanced gradient echo T2 star-weighted angiography (ESWAN to detect hemosiderin deposition on the cortical surface. The extent to which hemosiderin deposition was associated with several clinical factors was investigated. Various degrees of hemosiderin deposition were detected in 31 of 32 (96.9% single-episode tSAH patients. Analysis of contingency tables revealed an association between the regions of subarachnoid bleeding based on CT images and the regions of hemosiderin deposition based on ESWAN images (χ2 = 17.73, P<0.05. SS-CNS was determined to be a common consequence after a single episode of tSAH. The extent of hemosiderin deposition is closely correlated with the initial bleeding sites and bleeding volume.

  13. P61-S Multidimensional Liquid Chromatography of Proteins Using Monolithic Weak Anion Exchange and Reversed-Phase Columns

    OpenAIRE

    Sneekes, E.; van Ling, R.; de Haan, B.; Dolman, B.; Swart, R.; van Gils, M.

    2007-01-01

    Recent developments in monolithic column technology have yielded significant improvements in the biopolymer analysis field. Monolithic columns offer several advantages over particulate columns due to their macroporous structure, which provides fast mass transfer, low back pressure and high resolution. Polystyrene divinylbenzene (PS-DVB) monolithic columns are chemically inert; they offer high pH stability and excellent chromatographic performance in reversed-phase LC. While the application of...

  14. The influence of water vapour on the photocatalytic oxidation of cyclohexane in an internally illuminated monolith reactor

    OpenAIRE

    van Dijk, Vic; Simmelink, Gideon; Mul, Guido

    2014-01-01

    This paper discusses effects of humidity on photocatalytic cyclohexane oxidation performed in an internally illuminated monolith reactor equipped with an immobilised layer of approximately 3 μm titania (Hombikat uv100). Using dry nitrogen containing 10–20% of oxygen, cyclohexanone is produced with high selectivity (>90%) over cyclohexanol. The photocatalytic monolith deactivates within 80 min of operation. Regeneration of activity of such deactivated monolith is possible by air treatment at 4...

  15. Retrospective analysis of multiplex polymerase chain reaction-based molecular diagnostics (SES) in 70 patients with suspected central nervous system infections: A single-center study.

    Science.gov (United States)

    Ramalingam, Rama Krishnan Tiruppur Chinnappan; Chakraborty, Dipanjan

    2016-01-01

    Central nervous system (CNS) infections present a grave health care challenge due to high morbidity and mortality. Clinical findings and conventional laboratory assessments are not sufficiently distinct for specific etiologic diagnosis. Identification of pathogens is a key to appropriate therapy. In this retrospective observational study, we evaluated the efficacy and clinical utility of syndrome evaluation system (SES) for diagnosing clinically suspected CNS infections. This retrospective analysis included inpatients in our tertiary level neurointensive care unit (NICU) and ward from February 2010 to December 2013. Cerebrospinal fluid (CSF) samples of 70 patients, clinically suspected of having CNS infections, were subjected to routine laboratory tests, culture, imaging, and SES. We analyzed the efficacy of SES in the diagnosis of CNS infections and its utility in therapeutic decision-making. SES had a clinical sensitivity of 57.4% and clinical specificity of 95.6%. Streptococcus pneumoniae and Pseudomonas aeruginosa were the top two bacterial pathogens, whereas Herpes simplex virus (HSV) was the most common viral pathogen. Polymicrobial infections were detected in 32.14% of SES-positive cases. SES elicited a change in the management in 30% of the patients from initial empiric therapy. At discharge, 51 patients recovered fully while 11 patients had partial recovery. Three-month follow-up showed only six patients to have neurological deficits. In a tertiary care center, etiological microbial diagnosis is central to appropriate therapy and outcomes. Sensitive and accurate multiplex molecular diagnostics play a critical role in not only identifying the causative pathogen but also in helping clinicians to institute appropriate therapy, reduce overuse of antimicrobials, and ensure superior clinical outcomes.

  16. Steam reforming of n-hexane on pellet and monolithic catalyst beds. A comparative study on improvements due to heat transfer

    Science.gov (United States)

    1981-01-01

    Monolithic catalysts with higher available active surface areas and better thermal conductivity than conventional pellets beds, making possible the steam reforming of fuels heavier than naphtha, were examined. Performance comparisons were made between conventional pellet beds and honeycomb monolith catalysts using n-hexane as the fuel. Metal-supported monoliths were examined. These offer higher structural stability and higher thermal conductivity than ceramic supports. Data from two metal monoliths of different nickel catalyst loadings were compared to pellets under the same operating conditions. Improved heat transfer and better conversion efficiencies were obtained with the monolith having higher catalyst loading. Surface-gas interaction was observed throughout the length of the monoliths.

  17. Green synthesis of mesoporous molecular sieve incorporated monoliths using room temperature ionic liquid and deep eutectic solvents.

    Science.gov (United States)

    Zhang, Li-Shun; Zhao, Qing-Li; Li, Xin-Xin; Li, Xi-Xi; Huang, Yan-Ping; Liu, Zhao-Sheng

    2016-12-01

    A hybrid monolith incorporated with mesoporous molecular sieve MCM-41 of uniform pore structure and high surface area was prepared with binary green porogens in the first time. With a mixture of room temperature ionic liquids and deep eutectic solvents as porogens, MCM-41 was modified with 3-(trimethoxysilyl) propyl methacrylate (γ-MPS) and the resulting MCM-41-MPS was incorporated into poly (BMA-co-EDMA) monoliths covalently. Because of good dispersibility of MCM-41-MPS in the green solvent-based polymerization system, high permeability and homogeneity for the resultant hybrid monolithic columns was achieved. The MCM-41-MPS grafted monolith was characterized by scanning electron microscopy, energy dispersive spectrometer area scanning, transmission electron microscopy, FT-IR spectra and nitrogen adsorption tests. Chromatographic performance of MCM-41-MPS grafted monolith was characterized by separating small molecules in capillary electrochromatography, including phenol series, naphthyl substitutes, aniline series and alkyl benzenes. The maximum column efficiency of MCM-41-MPS grafted monolith reached 209,000 plates/m, which was twice higher than the corresponding MCM-41-MPS free monolith. Moreover, successful separation of non-steroidal anti-inflammatory drugs and polycyclic aromatic hydrocarbons demonstrated the capacity in broad-spectrum application of the MCM-41-MPS incorporated monolith. The results indicated that green synthesis using room temperature ionic liquid and deep eutectic solvents is an effective method to prepare molecular sieve-incorporated monolithic column. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Measurement and Modeling of the Transfer Function of a Monolithic SOA-EA 2R-Regenerator

    DEFF Research Database (Denmark)

    Christiansen, Lotte Jin; Öhman, Filip; Kjær, Rasmus

    2005-01-01

    We have measured steep power transfer characteristics with tunable threshold for a monolithic 2R-regenerator combining amplifying and absorbing sections. Modeling results explain the basic characteristics....

  19. A monolithic RF transceiver for DC-OFDM UWB

    International Nuclear Information System (INIS)

    Chen Yunfeng; Li Wei; Fu Haipeng; Gao Ting; Chen Danfeng; Zhou Feng; Cai Deyun; Li Dan; Niu Yangyang; Zhou Hanchao; Zhu Ning; Li Ning; Ren Junyan

    2012-01-01

    This paper presents a first monolithic RF transceiver for DC-OFDM UWB applications. The proposed direct-conversion transceiver integrates all the building blocks including two receiver (Rx) cores, two transmitter (Tx) cores and a dual-carrier frequency synthesizer (DC-FS) as well as a 3-wire serial peripheral interface (SPI) to set the operating status of the transceiver. The ESD-protected chip is fabricated by a TSMC 0.13-μm RF CMOS process with a die size of 4.5 × 3.6 mm 2 . The measurement results show that the wideband Rx achieves an NF of 5–6.2 dB, a max gain of 76–84 dB with 64-dB variable gain, an in-/out-of-band IIP3 of −6/+4 dBm and an input loss S 11 of < −10 in all bands. The Tx achieves an LOLRR/IMGRR of −34/-33 dBc, a typical OIP3 of +6 dBm and a maximum output power of −5 dBm. The DC-FS outputs two separate carriers simultaneously with an inter-band hopping time of < 1.2 ns. The full chip consumes a maximum current of 420 mA under a 1.2-V supply. (semiconductor integrated circuits)

  20. Monolithic III-nitride photonic integration toward multifunctional devices.

    Science.gov (United States)

    Gao, Xumin; Shi, Zheng; Jiang, Yan; Zhang, Shuai; Qin, Chuan; Yuan, Jialei; Liu, Yuhuai; Grünberg, Peter; Wang, Yongjin

    2017-12-01

    The multiple functionalities of III-nitride semiconductors enable the integration with different components into a multicomponent system with enhanced functions. Here, we propose to fabricate and characterize a monolithic InGaN photonic circuit of a transmitter, waveguide, and receiver on an III-nitride-on-silicon platform. Both the transmitter and the receiver, sharing identical InGaN/GaN multiple-quantum-well structures and fabrication procedures, work to emit light and detect light independently. The 8 μm wide and 200 μm long InGaN waveguide couples the modulated light from the transmitter and sends the guided light to the receiver, leading to the formation of an in-plane light transmission system. The induced photocurrent at the receiver is highly sensitive to the light output of the transmitter. Multi-dimensional light transmissions are experimentally demonstrated at 200 Mb/s. These multifunctional photonic circuits open feasible approaches to the development of III-nitride multicomponent systems with integrated functions for comprehensive applications in the visible region.

  1. Considerations for creating a free-standing monolith

    International Nuclear Information System (INIS)

    Salsman, J.M.

    1985-01-01

    The Texas Low-Level Radioactive Waste Disposal Authority is investigating alternatives to shallow-land burial for low-level radioactive waste. This alternative proposes a standard shallow-land burial trench with a reinforced concrete floor over a sand bottom, backfilling the trench voids with concrete instead of sand and using a concrete cap covered with clay and top soil. The use of concrete backfilled trenches in a geologically stable, semi-arid area can provide an additional degree of safety, but their use in a geologically unfavorable area could actually create problems. Three reasons for using concrete backfill are: better intruder barriers, creation of a concrete monolith, and lower susceptibility to subsidence. A fourth nontechnical reason is that the public seems to be infatuated with concrete, which may prove to be the best reason for a concrete backfilled trench. The additional cost of using concrete is approximately $7.78/ft 3 of waste buried if the concrete is commercially purchased; however, if a batch plant is utilized, the cost is reduced to $1.43/ft 3

  2. IRRADIATION PERFORMANCE OF U-Mo MONOLITHIC FUEL

    Directory of Open Access Journals (Sweden)

    M.K. MEYER

    2014-04-01

    Full Text Available High-performance research reactors require fuel that operates at high specific power to high fission density, but at relatively low temperatures. Research reactor fuels are designed for efficient heat rejection, and are composed of assemblies of thin-plates clad in aluminum alloy. The development of low-enriched fuels to replace high-enriched fuels for these reactors requires a substantially increased uranium density in the fuel to offset the decrease in enrichment. Very few fuel phases have been identified that have the required combination of very-high uranium density and stable fuel behavior at high burnup. UMo alloys represent the best known tradeoff in these properties. Testing of aluminum matrix U-Mo aluminum matrix dispersion fuel revealed a pattern of breakaway swelling behavior at intermediate burnup, related to the formation of a molybdenum stabilized high aluminum intermetallic phase that forms during irradiation. In the case of monolithic fuel, this issue was addressed by eliminating, as much as possible, the interfacial area between U-Mo and aluminum. Based on scoping irradiation test data, a fuel plate system composed of solid U-10Mo fuel meat, a zirconium diffusion barrier, and Al6061 cladding was selected for development. Developmental testing of this fuel system indicates that it meets core criteria for fuel qualification, including stable and predictable swelling behavior, mechanical integrity to high burnup, and geometric stability. In addition, the fuel exhibits robust behavior during power-cooling mismatch events under irradiation at high power.

  3. Ionic liquids monolithic columns for protein separation in capillary electrochromatography.

    Science.gov (United States)

    Liu, Cui-Cui; Deng, Qi-Liang; Fang, Guo-Zhen; Liu, Hui-Lin; Wu, Jian-Hua; Pan, Ming-Fei; Wang, Shuo

    2013-12-04

    A series of ionic liquids (ILs) monolithic capillary columns based on 1-vinyl-3-octylimidazolium (ViOcIm(+)) were prepared by two approaches ("one-pot" approach and "anion-exchange" approach). The effects of different anions (bromide, Br(-); tetrafluoroborate, BF4(-); hexafluorophosphate, PF6(-); and bis-trifluoromethanesulfonylimide, NTf2(-)) on chromatography performance of all the resulting columns were investigated systematically under capillary electrochromatography (CEC) mode. The results indicated that all these columns could generate a stable reversed electroosmotic flow (EOF) over a wide pH range from 2.0 to 12.0. For the columns prepared by "one-pot" approach, the EOF decreased in the order of ViOcIm(+)Br(-)>ViOcIm(+)BF4(-)>ViOcIm(+)PF6(-)>ViOcIm(+)NTf2(-) under the same CEC conditions; the ViOcIm(+)Br(-) based column exhibited highest column efficiencies for the test small molecules; the ViOcIm(+)NTf2(-) based column possessed the strongest retention for aromatic hydrocarbons; and baseline separation of four standard proteins was achieved on ViOcIm(+)NTf2(-) based column corresponding to the highest column efficiency of 479,000 N m(-1) for cytochrome c (Cyt c). These results indicated that the property of ILs based columns could be tuned successfully by changing anions, which gave these columns potential to separate both small molecules and macro biomolecules. Crown Copyright © 2013. Published by Elsevier B.V. All rights reserved.

  4. Sausage Waves in Transversely Nonuniform Monolithic Coronal Tubes

    Science.gov (United States)

    Lopin, I.; Nagorny, I.

    2015-09-01

    We investigate fast sausage waves in a monolithic coronal magnetic tube, modeled as a local density inhomogeneity with a continuous radial profile. This work is a natural extension of our previous results, obtained for a slab loop model for the case of cylindrical geometry. Using Kneser’s oscillating theorem, we provided the criteria for the existence of trapped and leaky wave regimes as a function of the profile features. For a number of density profiles there are only trapped modes for the entire range of longitudinal wave numbers. The phase speed of these modes tends toward the external Alfvén speed in the long wavelength limit. The generalized results were supported by the analytic solution of the wave equation for the specific density profiles. The approximate Wentzel-Kramers-Brillouin solutions allowed us to obtain the desired dispersion relations and to study their properties as a function of the profile parameters. The multicomponent quasi-periodic pulsations in flaring loops, observed on 2001 May 2 and 2002 July 3, are interpreted in terms of the transversely fundamental trapped fast sausage mode with several longitudinal harmonics in a smooth coronal waveguide.

  5. SAUSAGE WAVES IN TRANSVERSELY NONUNIFORM MONOLITHIC CORONAL TUBES

    International Nuclear Information System (INIS)

    Lopin, I.; Nagorny, I.

    2015-01-01

    We investigate fast sausage waves in a monolithic coronal magnetic tube, modeled as a local density inhomogeneity with a continuous radial profile. This work is a natural extension of our previous results, obtained for a slab loop model for the case of cylindrical geometry. Using Kneser’s oscillating theorem, we provided the criteria for the existence of trapped and leaky wave regimes as a function of the profile features. For a number of density profiles there are only trapped modes for the entire range of longitudinal wave numbers. The phase speed of these modes tends toward the external Alfvén speed in the long wavelength limit. The generalized results were supported by the analytic solution of the wave equation for the specific density profiles. The approximate Wentzel–Kramers–Brillouin solutions allowed us to obtain the desired dispersion relations and to study their properties as a function of the profile parameters. The multicomponent quasi-periodic pulsations in flaring loops, observed on 2001 May 2 and 2002 July 3, are interpreted in terms of the transversely fundamental trapped fast sausage mode with several longitudinal harmonics in a smooth coronal waveguide

  6. Pressure-actuated monolithic acrylic microfluidic valves and pumps.

    Science.gov (United States)

    Guevara-Pantoja, Pablo E; Jiménez-Valdés, Rocío J; García-Cordero, Jose L; Caballero-Robledo, Gabriel A

    2018-02-13

    In this article, we describe a microfluidic device with embedded valves and pumps made exclusively of layers of acrylic glass. Flat acrylic sheets are carved out with a micromilling machine and bonded together by solvent bonding. The working principle of the valves is based on a thin flexible membrane (≈100 μm) machined on one acrylic sheet and actuated with pneumatic pressure. A completely closed valve resists a pressure difference of ≈17 kPa (≈2.5 psi), and when open, it can sustain flow rates of up to 100 μL s -1 . Pumping is achieved by combining two valves and a pumping chamber in series, which is also based on the bending of a thin acrylic membrane. The maximum flow rate obtained with this pumping mechanism is 20 μL min -1 . Acrylic is a popular rigid thermoplastic because it is inexpensive, making it ideal for mass production of disposable devices, and also because it has demonstrated compatibility with different biochemical assays. The physical and optical properties it shares with other thermoplastics could lead to this material being implemented for similar valves and pumps. As a proof-of-concept of our technology, we implemented a controlled cell-staining assay in two parallel incubation chambers integrating four valves and one pump into one device. Our monolithic acrylic valves can enable the mass production of disposable microfluidic devices that require fluid control with pressure-actuated valves and aid in the automation of biochemical assays.

  7. Deep-red semiconductor monolithic mode-locked lasers

    Energy Technology Data Exchange (ETDEWEB)

    Kong, L.; Bajek, D.; White, S. E.; Forrest, A. F.; Cataluna, M. A., E-mail: m.a.cataluna@dundee.ac.uk [School of Engineering, Physics and Mathematics, University of Dundee, Dundee DD1 4HN (United Kingdom); Wang, H. L.; Pan, J. Q. [Institute of Semiconductors, Chinese Academy of Sciences, Beijing 100083 (China); Wang, X. L.; Cui, B. F. [Key Laboratory of Opto-electronics Technology, Ministry of Education, Beijing University of Technology, Beijing 100124 (China); Ding, Y. [School of Engineering, Physics and Mathematics, University of Dundee, Dundee DD1 4HN (United Kingdom); School of Engineering, University of Glasgow, Glasgow G12 8LT (United Kingdom)

    2014-12-01

    A deep-red semiconductor monolithic mode-locked laser is demonstrated. Multi-section laser diodes based on an AlGaAs multi-quantum-well structure were passively mode-locked, enabling the generation of picosecond optical pulses at 752 nm, at pulse repetition rates of 19.37 GHz. An investigation of the dependence of the pulse duration as a function of reverse bias revealed a predominantly exponential decay trend of the pulse duration, varying from 10.5 ps down to 3.5 ps, which can be associated with the concomitant reduction of absorption recovery time with increasing applied field. A 30-MHz-tunability of the pulse repetition rate with bias conditions is also reported. The demonstration of such a compact, efficient and versatile ultrafast laser in this spectral region paves the way for its deployment in a wide range of applications such as biomedical microscopy, pulsed terahertz generation as well as microwave and millimeter-wave generation, with further impact on sensing, imaging and optical communications.

  8. A Differential Monolithically Integrated Inductive Linear Displacement Measurement Microsystem

    Directory of Open Access Journals (Sweden)

    Matija Podhraški

    2016-03-01

    Full Text Available An inductive linear displacement measurement microsystem realized as a monolithic Application-Specific Integrated Circuit (ASIC is presented. The system comprises integrated microtransformers as sensing elements, and analog front-end electronics for signal processing and demodulation, both jointly fabricated in a conventional commercially available four-metal 350-nm CMOS process. The key novelty of the presented system is its full integration, straightforward fabrication, and ease of application, requiring no external light or magnetic field source. Such systems therefore have the possibility of substituting certain conventional position encoder types. The microtransformers are excited by an AC signal in MHz range. The displacement information is modulated into the AC signal by a metal grating scale placed over the microsystem, employing a differential measurement principle. Homodyne mixing is used for the demodulation of the scale displacement information, returned by the ASIC as a DC signal in two quadrature channels allowing the determination of linear position of the target scale. The microsystem design, simulations, and characterization are presented. Various system operating conditions such as frequency, phase, target scale material and distance have been experimentally evaluated. The best results have been achieved at 4 MHz, demonstrating a linear resolution of 20 µm with steel and copper scale, having respective sensitivities of 0.71 V/mm and 0.99 V/mm.

  9. Monolithic subwavelength high refractive-index-contrast grating VCSELs

    Science.gov (United States)

    Gebski, Marcin; Dems, Maciej; Lott, James A.; Czyszanowski, Tomasz

    2016-03-01

    In this paper we present optical design and simulation results of vertical-cavity surface-emitting lasers (VCSELs) that incorporate monolithic subwavelength high refractive-index-contrast grating (MHCG) mirrors - a new variety of HCG mirror that is composed of high index material surrounded only on one side by low index material. We show the impact of an MHCG mirror on the performance of 980 nm VCSELs designed for high bit rate and energy-efficient optical data communications. In our design, all or part of the all-semiconductor top coupling distributed Bragg reflector mirror is replaced by an undoped gallium-arsenide MHCG. We show how the optical field intensity distribution of the VCSEL's fundamental mode is controlled by the combination of the number of residual distributed Bragg reflector (DBR) mirror periods and the physical design of the topmost gallium-arsenide MHCG. Additionally, we numerically investigate the confinement factors of our VCSELs and show that this parameter for the MHCG DBR VCSELs may only be properly determined in two or three dimensions due to the periodic nature of the grating mirror.

  10. Electromechanical displacement of piezoelectric-electrostrictive monolithic bilayer composites

    Science.gov (United States)

    Ngernchuklin, P.; Akdoǧan, E. K.; Safari, A.; Jadidian, B.

    2009-02-01

    We examine the electromechanical displacement of piezoelectric-electrostrictive monolithic bilayer composites with various piezoelectric volume percentage obtained by cosintering piezoelectric 0.65Pb(Mg1/3Nb2/3)O3-0.35PbTiO3 and electrostrictive 0.9Pb(Mg1/3Nb2/.3)O3-0.1PbTiO3 under unipolar and bipolar electric field excitation up to 10 kV/cm experimentally. It is shown that the effective d33 of the composites is limited by the electrostrictive layer, which acts as a capacitor in series to the piezoelectric layer, causing incomplete poling. We show that by controlling the volume content of the piezoelectric layer and constraining it with an electrostrictor, substantial strain amplification (15 μm for bipolar excitation) can be achieved while inducing asymmetry to the displacement with respect to the polarity of the applied field, which we discuss in the context of symmetry superposition.

  11. Monolithic active pixel sensors (MAPS) in a VLSI CMOS technology

    CERN Document Server

    Turchetta, R; Manolopoulos, S; Tyndel, M; Allport, P P; Bates, R; O'Shea, V; Hall, G; Raymond, M

    2003-01-01

    Monolithic Active Pixel Sensors (MAPS) designed in a standard VLSI CMOS technology have recently been proposed as a compact pixel detector for the detection of high-energy charged particle in vertex/tracking applications. MAPS, also named CMOS sensors, are already extensively used in visible light applications. With respect to other competing imaging technologies, CMOS sensors have several potential advantages in terms of low cost, low power, lower noise at higher speed, random access of pixels which allows windowing of region of interest, ability to integrate several functions on the same chip. This brings altogether to the concept of 'camera-on-a-chip'. In this paper, we review the use of CMOS sensors for particle physics and we analyse their performances in term of the efficiency (fill factor), signal generation, noise, readout speed and sensor area. In most of high-energy physics applications, data reduction is needed in the sensor at an early stage of the data processing before transfer of the data to ta...

  12. Compressible, Dense, Three-Dimensional Holey Graphene Monolithic Architecture.

    Science.gov (United States)

    Han, Xiaogang; Yang, Zhi; Zhao, Bin; Zhu, Shuze; Zhou, Lihui; Dai, Jiaqi; Kim, Jae-Woo; Liu, Boyang; Connell, John W; Li, Teng; Yang, Bao; Lin, Yi; Hu, Liangbing

    2017-03-28

    By creating holes in 2D nanosheets, tortuosity and porosity can be greatly tunable, which enables a fast manufacturing process (i.e., fast removal of gas and solvent) toward various nanostructures. We demonstrated outstanding compressibility of holey graphene nanosheets, which is impossible for pristine graphene. Holey graphene powder can be easily compressed into dense and strong monoliths with different shapes at room temperature without using any solvents or binders. The remarkable compressibility of holey graphene, which is in sharp contrast with pristine graphene, not only enables the fabrication of robust, dense graphene products that exhibit high density (1.4 g/cm 3 ), excellent specific mechanical strength [18 MPa/(g/cm 3 )], and good electrical (130 S/cm) and thermal (20 W/mK) conductivities, but also provides a binder-free dry process that overcomes the disadvantages of wet processes required for fabrication of three-dimensional graphene products. Fundamentally different from graphite, the holey graphene products are both dense and porous, which can enable possible broader applications such as energy storage and gas separation membranes.

  13. Viscoplastic Constitutive Theory Demonstrated for Monolithic Ceramic Materials

    Science.gov (United States)

    Janosik, Lesley A.

    1999-01-01

    Development of accurate three-dimensional (multiaxial) inelastic stress-strain models is critical in utilizing advanced ceramics for challenging 21st century high-temperature structural applications. The current state of the art uses elastic stress fields as a basis for both subcritical crack growth and creep life prediction efforts aimed at predicting the time dependent reliability response of ceramic components subjected to elevated service temperatures. However, to successfully design components that will meet tomorrow's challenging requirements, design engineers must recognize that elastic predictions are inaccurate for these materials when subjected to high-temperature service conditions such as those encountered in advanced heat engine components. Analytical life prediction methodologies developed for advanced ceramics and other brittle materials must employ accurate constitutive models that capture the inelastic response exhibited by these materials at elevated service temperatures. A constitutive model recently developed at the NASA Lewis Research Center helps address this issue by accounting for the time-dependent (inelastic) material deformation phenomena (e.g., creep, rate sensitivity, and stress relaxation) exhibited by monolithic ceramics exposed to high-temperature service conditions. In addition, the proposed formulation is based on a threshold function that is sensitive to hydrostatic stress and allows different behavior in tension and compression, reflecting experimental observations obtained for these material systems.

  14. FIBROUS MONOLITH WEAR RESISTANT COMPONENTS FOR THE MINING INDUSTRY

    Energy Technology Data Exchange (ETDEWEB)

    Mark J. Rigali; Kenneth L. Knittel; Mike L. Fulcher

    2002-03-01

    During this reporting period, work continued on development of formulations using the materials identified as contenders for the fibrous monolith wear resistant components. The FM structures fabricated were: diamond/WC-Co, B{sub 4}C/WC-Co, TiB{sub 2}/WC-Co, WC-Co/Co, WC-Co/WC-Co. Results of our consolidation densification studies on these systems lead to the down-selection of WC-Co/WC-Co, WC-Co/Co and diamond/WC-Co for further development for mining applications including drill bit inserts, roof bit inserts, radial tools conical tools and wear plates (WC-Co based system only) for earth moving equipment. Prototype component fabrication focused on the fabrication of WC-Co/WC-Co FM conical tools, diamond/WC-Co coated drill bit insert prototypes. Fabrication of WC-Co/WC-Co FM insert prototypes for a grader blade is also underway. ACR plans to initiate field-testing of the drill bit insert prototypes and the grader blade insert this summer (2002). The first WC-Co/WC-Co FM conical tool prototypes were sent to Kennametal for evaluation towards the end of the current reporting period.

  15. Immediate Implant Placement of a Single Central Incisor Using a CAD/CAM Crown-Root Form Technique: Provisional to Final Restoration.

    Science.gov (United States)

    Vafiadis, Dean; Goldstein, Gary; Garber, David; Lambrakos, Anthony; Kowalski, Bj

    2017-02-01

    Preserving soft and hard tissues after extraction and implant placement is crucial for anterior esthetics. This technique will show how the information gathered from a cone-beam computed tomography (CBCT) scan of the maxillary left central incisor and an intra-oral digital impression can be merged to fabricate a CAD/CAM crown-root matrix to be used as an immediate provisional restoration that mimics the natural anatomy. Due to trauma, a left central incisor appeared to be fractured and was scheduled for extraction and implant placement. The crown-root configuration captured by the CBCT scan was merged with the digital files from an intra-oral digital impression. A CAD/CAM crown-root matrix was fabricated. Because the matrix shell was fabricated with the exact anatomy of the natural tooth, it replicated the position and three dimensional anatomy of the soft and hard tissue. It was connected to the implant with a customized provisional abutment. A digital impression of a coded healing abutment was made to fabricate the final implant abutment and final restoration. Throughout the treatment time and 36 months after completion, the thickness of tissue, emergence profile, and adjacent papilla was analyzed by clinical evaluation and photography and seemed to be maintained. The use of a pre-operative intra-oral digital scan of the clinical crown-root architecture and the CBCT scan of the bone/root anatomy, can be used together to fabricate a CAD/CAM crown-root form provisional matrix. This digital design helps in the preservation of the 3D tissue topography, as well as the final restoration. The preservation of soft and hard tissue after extraction and implant placement has always been paramount for ideal anterior implant esthetics. Using the information from digital files from CBCT scans and intra-oral scans may help the clinician identify critical anatomical features that can be replicated in the provisional and final CAD/CAM restoration. (J Esthet Restor Dent 29

  16. Method to make a single-step etch mask for 3D monolithic nanostructures

    NARCIS (Netherlands)

    Grishina, Diana; Harteveld, Cornelis A.M.; Woldering, L.A.; Vos, Willem L.

    2015-01-01

    Current nanostructure fabrication by etching is usually limited to planar structures as they are defined by a planar mask. The realization of three-dimensional (3D) nanostructures by etching requires technologies beyond planar masks. We present a method for fabricating a 3D mask that allows one to

  17. On-chip optical phase locking of single growth monolithically integrated Slotted Fabry Perot lasers.

    Science.gov (United States)

    Morrissey, P E; Cotter, W; Goulding, D; Kelleher, B; Osborne, S; Yang, H; O'Callaghan, J; Roycroft, B; Corbett, B; Peters, F H

    2013-07-15

    This work investigates the optical phase locking performance of Slotted Fabry Perot (SFP) lasers and develops an integrated variable phase locked system on chip for the first time to our knowledge using these lasers. Stable phase locking is demonstrated between two SFP lasers coupled on chip via a variable gain waveguide section. The two lasers are biased differently, one just above the threshold current of the device with the other at three times this value. The coupling between the lasers can be controlled using the variable gain section which can act as a variable optical attenuator or amplifier depending on bias. Using this, the width of the stable phase locking region on chip is shown to be variable.

  18. Research and Development of Monolithic Active Pixel Sensors for the Detection of the Elementary Particles

    International Nuclear Information System (INIS)

    Li, Y.

    2007-09-01

    In order to develop high spatial resolution and readout speed vertex detectors for the future International Linear Collider (ILC), fast CMOS Monolithic Active Pixel Sensors (MAPS) are studied on this work. Two prototypes of MAPS, MIMOSA 8 and MIMOSA 16, based on the same micro-electronic architecture were developed in CMOS processes with different thickness of epitaxial layer. The size of pixel matrix is 32 x 128: 8 columns of the pixel array are readout directly with analog outputs and the other 24 columns are connected to the column level auto-zero discriminators. The Correlated Double Sampling (CDS) structures are successfully implemented inside pixel and discriminator. The photo diode type pixels with different diode sizes are used in these prototypes. With a 55 Fe X-ray radioactive source, the important parameters, such as Temporal Noise, Fixed Pattern Noise (FPN), Signal-to-Noise Ratio (SNR), Charge-to-Voltage conversion Factor (CVF) and Charge Collection Efficiency (CCE), are studied as function of readout speed and diode size. For MIMOSA 8, the effect of fast neutrons irradiation is also. Two beam tests campaigns were made: at DESY with a 5 GeV electrons beam and at CERN with a 180 GeV pions beam. Detection Efficiency and Spatial Resolution are studied in function of the discriminator threshold. For these two parameters, the influences of diode size and SNR of the central pixel of a cluster are also discussed. In order to improve the spatial resolution of the digital outputs, a very compact (25 μm x 1 mm) and low consumption (300 μW) column level ADC is designed in AMS 0.35 μm OPTO process. Based on successive approximation architecture, the auto-offset cancellation structure is integrated. A new column level auto-zero discriminator using static latch is also designed. (author)

  19. Progress toward a 30 percent-efficient, monolithic, three-junction, two-terminal concentrator solar cell for space applications

    Science.gov (United States)

    Partain, L. D.; Chung, B.-C.; Virshup, G. F.; Schultz, J. C.; Macmillan, H. F.; Ristow, M. Ladle; Kuryla, M. S.; Bertness, K. A.

    1991-01-01

    Component efficiencies of 0.2/sq cm cells at approximately 100x AMO light concentration and 80 C temperatures are not at 15.3 percent for a 1.9 eV AlGaAs top cell, 9.9 percent for a 1.4 eV GaAs middle cell under a 1.9 eV AlGaAs filter, and 2.4 percent for a bottom 1.0 eV InGaAs cell under a GaAs substrate. The goal is to continue improvement in these performance levels and to sequentially grow these devices on a single substrate to give 30 percent efficient, monolithic, two-terminal, three-junction space concentrator cells. The broad objective is a 30 percent efficient monolithic two-terminal cell that can operate under 25 to 100x AMO light concentrations and at 75 to 100 C cell temperatures. Detailed modeling predicts that this requires three junctions. Two options are being pursued, and both use a 1.9 eV AlGaAs top junction and a 1.4 eV GaAs middle junction grown by a 1 atm OMVPE on a lattice matched substrate. Option 1 uses a low-doped GaAs substrate with a lattice mismatched 1.0 eV InGaAs cell formed on the back of the substrate. Option 2 uses a Ge substrate to which the AlGaAs and GaAs top junctions are lattice matched, with a bottom 0.7 eV Ge junction formed near the substrate interface with the GaAs growth. The projected efficiency contributions are near 16, 11, and 3 percent, respectively, from the top, middle, and bottom junctions.

  20. A novel ionic liquid monolithic column and its separation properties in capillary electrochromatography.

    Science.gov (United States)

    Wang, Yu; Deng, Qi-Liang; Fang, Guo-Zhen; Pan, Ming-Fei; Yu, Yang; Wang, Shuo

    2012-01-27

    A novel ionic liquid (IL) monolithic capillary column was successfully prepared by thermal free radical copolymerization of IL (1-vinyl-3-octylimidazolium chloride, ViOcIm(+)Cl(-)) together with lauryl methacrylate (LMA) as the binary functional monomers and ethylene dimethacrylate (EDMA) as the cross-linker in binary porogen. The proportion of monomers, porogens and cross-linker in the polymerization mixture was optimized in detail. The resulting IL-monolithic column could not only generate a stable reversed electroosmotic flow (EOF) in a wide pH range (2.0-12.0), but also effectively eliminate the wall adsorption of the basic analytes. The obtained IL-monolithic columns were examined by scanning electron microscopy (SEM) and Fourier transform infrared (FT-IR). These results indicated that the IL-monolithic capillary column possessed good pore properties, mechanical stability and permeability. The column performance was also evaluated by separating different kinds of compounds, such as alkylbenzenes, thiourea and its analogues, and amino acids. The lowest plate height of ~6.8 μm was obtained, which corresponded to column efficiency (theoretical plates, N) of ~147,000 plates m(-1) for thiourea. ILs, as a new type of functional monomer, present a promising option in the fabrication of the organic polymer-based monolithic columns in CEC. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Use of monolithic supports for high-throughput protein and peptide separation in proteomics.

    Science.gov (United States)

    Andjelković, Uroš; Tufegdžić, Srdjan; Popović, Milica

    2017-11-01

    The exclusive properties of monolithic supports enable fast mass transfer, high porosity, low back pressure, easy preparation process and miniaturisation, and the availability of different chemistries make them particularly suitable materials for high-throughput (HTP) protein and peptide separation. In this review recent advances in monolith-based chromatographic supports for HTP screening of protein and peptide samples are presented and their application in HTP sample preparation (separation, enrichment, depletion, proteolytic digestion) for HTP proteomics is discussed. Development and applications of different monolithic capillary columns in HTP MS-based bottom-up and top-down proteomics are overviewed. By discussing the chromatographic conditions and the mass spectrometric data acquisition conditions an attempt is made to present currently demonstrated capacities of monolithic capillary columns for HTP identification and quantification of proteins and peptides from complex biological samples by MS-based proteomics. Some recent advances in basic monolith technology of importance for proteomics are also discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Influence of the preparation design and artificial aging on the fracture resistance of monolithic zirconia crowns.

    Science.gov (United States)

    Mitov, Gergo; Anastassova-Yoshida, Yana; Nothdurft, Frank Phillip; von See, Constantin; Pospiech, Peter

    2016-02-01

    The aim of this study was to evaluate the fracture resistance and fracture behavior of monolithic zirconia crowns in accordance with the preparation design and aging simulation method. An upper first molar was prepared sequentially with three different preparation designs: shoulderless preparation, 0.4 mm chamfer and 0.8 mm chamfer preparation. For each preparation design, 30 monolithic zirconia crowns were fabricated. After cementation on Cr-Co alloy dies, the following artificial aging procedures were performed: (1) thermal cycling and mechanical loading (TCML): 5000 cycles of thermal cycling 5℃-55℃ and chewing simulation (1,200,000 cycles, 50 N); (2) Low Temperature Degradation simulation (LTD): autoclave treatment at 137℃, 2 bar for 3 hours and chewing simulation; and (3) no pre-treatment (control group). After artificial aging, the crowns were loaded until fracture. The mean values of fracture resistance varied between 3414 N (LTD; 0.8 mm chamfer preparation) and 5712 N (control group; shoulderless preparation). Two-way ANOVA analysis showed a significantly higher fracture loads for the shoulderless preparation, whereas no difference was found between the chamfer preparations. In contrast to TCML, after LTD simulation the fracture strength of monolithic zirconia crowns decreased significantly. The monolithic crowns tested in this study showed generally high fracture load values. Preparation design and LTD simulation had a significant influence on the fracture strength of monolithic zirconia crowns.

  3. A monolithic lipase reactor for biodiesel production by transesterification of triacylglycerides into fatty acid methyl esters.

    Science.gov (United States)

    Urban, Jiri; Svec, Frantisek; Fréchet, Jean M J

    2012-02-01

    An enzymatic reactor with lipase immobilized on a monolithic polymer support has been prepared and used to catalyze the transesterification of triacylglycerides into the fatty acid methyl esters commonly used for biodiesel. A design of experiments procedure was used to optimize the monolithic reactor with variables including control of the surface polarity of the monolith via variations in the length of the hydrocarbon chain in alkyl methacrylate monomer, time of grafting of 1-vinyl-4,4-dimethylazlactone used to activate the monolith, and time used for the immobilization of porcine lipase. Optimal conditions involved the use of a poly(stearyl methacrylate-co-ethylene dimethacrylate) monolith, grafted first with vinylazlactone, then treated with lipase for 2 h to carry out the immobilization of the enzyme. Best conditions for the transesterification of glyceryl tributyrate included a temperature of 37°C and a 10 min residence time of the substrate in the bioreactor. The reactor did not lose its activity even after pumping through it a solution of substrate equaling 1,000 reactor volumes. This enzymatic reactor was also used for the transesterification of triacylglycerides from soybean oil to fatty acid methyl esters thus demonstrating the ability of the reactor to produce biodiesel. Copyright © 2011 Wiley Periodicals, Inc.

  4. Applications of monolithic solid-phase extraction in chromatography-based clinical chemistry assays.

    Science.gov (United States)

    Bunch, Dustin R; Wang, Sihe

    2013-04-01

    Complex matrices, for example urine, serum, plasma, and whole blood, which are common in clinical chemistry testing, contain many non-analyte compounds that can interfere with either detection or in-source ionization in chromatography-based assays. To overcome this problem, analytes are extracted by protein precipitation, solid-phase extraction (SPE), and liquid-liquid extraction. With correct chemistry and well controlled material SPE may furnish clean specimens with consistent performance. Traditionally, SPE has been performed with particle-based adsorbents, but monolithic SPE is attracting increasing interest of clinical laboratories. Monoliths, solid pieces of stationary phase, have bimodal structures consisting of macropores, which enable passage of solvent, and mesopores, in which analytes are separated. This structure results in low back-pressure with separation capabilities similar to those of particle-based adsorbents. Monoliths also enable increased sample throughput, reduced solvent use, varied support formats, and/or automation. However, many of these monoliths are not commercially available. In this review, application of monoliths to purification of samples from humans before chromatography-based assays will be critically reviewed.

  5. Recent Advances and Uses of Monolithic Columns for the Analysis of Residues and Contaminants in Food

    Directory of Open Access Journals (Sweden)

    Mónica Díaz-Bao

    2015-02-01

    Full Text Available Monolithic columns are gaining interest as excellent substitutes to conventional particle-packed columns. These columns show higher permeability and lower flow resistance than conventional liquid chromatography columns, providing high-throughput performance, resolution and separation in short run times. Monoliths possess also great potential for the clean-up and preparation of complex mixtures. In situ polymerization inside appropriate supports allows the development of several microextraction formats, such as in-tube solid-phase and pipette tip-based extractions. These techniques using porous monoliths offer several advantages, including miniaturization and on-line coupling with analytical instruments. Additionally, monoliths are ideal support media for imprinting template-specific sites, resulting in the so-called molecularly-imprinted monoliths, with ultra-high selectivity. In this review, time-saving LC columns and preparative applications applied to the analysis of residues and contaminants in food in 2010–2014 are described, focusing on recent improvements in design and with emphasis in automated on-line systems and innovative materials and formats.

  6. Mesoporous aluminosilica monoliths for the adsorptive removal of small organic pollutants.

    Science.gov (United States)

    El-Safty, Sherif A; Shahat, Ahmed; Ismael, Mohamed

    2012-01-30

    Water treatment for the removal of organic or inorganic pollutants has become a serious global issue because of the increasing demand for public health awareness and environmental quality. The current paper, reports the applicability of mesoporous aluminosilica monoliths with three-dimensional structures and aluminum contents with 19≤Si/Al≥1 as effective adsorbents of organic molecules from an aqueous solution. Mesocage cubic Pm3n aluminosilica monoliths were successfully fabricated using a simple, reproducible, and direct synthesis. The acidity of the monoliths significantly increased with increasing amounts of aluminum species in the silica pore framework walls. The batch adsorption of the organic pollutants onto (10 g/L) aluminosilica monoliths was performed in an aqueous solution at various temperatures. These adsorbents exhibit efficient removal of organic pollutants (e.g., aniline, p-chloroaniline, o-aminophenol, and p-nitroaniline) of up to 90% within a short period (in the order of minutes). In terms of proximity adsorption, the functional acid sites and the condensed and rigid monoliths with tunable periodic scaffolds of the cubic mesocages are useful in providing easy-to-use removal assays for organic compounds and reusable adsorbents without any mesostructural damage, even under chemical treatment for a number of repeated cycles. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Effects of surface treatments on the translucency, opalescence, and surface texture of dental monolithic zirconia ceramics.

    Science.gov (United States)

    Kim, Hee-Kyung; Kim, Sung-Hun; Lee, Jai-Bong; Ha, Seung-Ryong

    2016-06-01

    Surface polishing or glazing may increase the appearance of depth of monolithic zirconia restorations. The purpose of this in vitro study was to investigate the effects of surface treatments on the translucency, opalescence, and surface texture of dental monolithic zirconia ceramics. Forty-five monolithic zirconia specimens (16.3×16.4×2.0 mm) were divided into groups I to V, according to the number of colorings each received. Each group was then divided into 3 subgroups (n=3) according to the surface treatment: N=no treatment; P=polished; and G=glazed. CIElab color coordinates were obtained relative to D65 on a reflection spectrophotometer. The translucency parameter (TP) and opalescence parameter (OP) were calculated. One specimen per subgroups I and V was selected for evaluation of surface roughness (Ra) and was examined with scanning electron microscopy (SEM). Data were analyzed with 2-way ANOVA and pairwise comparisons (α=.05). Statistical powers were verified to evaluate results (α=.05). The interaction effects of surface treatments combined with the number of colorings were significant for TP, OP, and Ra (P.05), whereas glazing significantly decreased OP and Ra in most groups. SEM images demonstrated that surface treatments affected the surface texture of monolithic zirconia ceramics. Surface treatments combined with coloring strongly affect the surface texture of dental monolithic zirconia ceramics. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  8. A monolithic lipase reactor for biodiesel production by transesterification of triacylglycerides into fatty acid methyl esters

    KAUST Repository

    Urban, Jiří T.

    2011-09-26

    An enzymatic reactor with lipase immobilized on a monolithic polymer support has been prepared and used to catalyze the transesterification of triacylglycerides into the fatty acid methyl esters commonly used for biodiesel. A design of experiments procedure was used to optimize the monolithic reactor with variables including control of the surface polarity of the monolith via variations in the length of the hydrocarbon chain in alkyl methacrylate monomer, time of grafting of 1-vinyl-4,4-dimethylazlactone used to activate the monolith, and time used for the immobilization of porcine lipase. Optimal conditions involved the use of a poly(stearyl methacrylate-co-ethylene dimethacrylate) monolith, grafted first with vinylazlactone, then treated with lipase for 2h to carry out the immobilization of the enzyme. Best conditions for the transesterification of glyceryl tributyrate included a temperature of 37°C and a 10min residence time of the substrate in the bioreactor. The reactor did not lose its activity even after pumping through it a solution of substrate equaling 1,000 reactor volumes. This enzymatic reactor was also used for the transesterification of triacylglycerides from soybean oil to fatty acid methyl esters thus demonstrating the ability of the reactor to produce biodiesel. © 2011 Wiley Periodicals, Inc.

  9. Polymer monoliths with chelating functionalities for solid phase extraction of metal ions from water.

    Science.gov (United States)

    Wang, Hongxia; Zhang, Haiyang; Lv, Yongqin; Svec, Frantisek; Tan, Tianwei

    2014-05-23

    Simple devices for the adsorption and preconcentration of metal ions comprising various monolithic polymers have been prepared by in situ polymerization within the 5.5cm long and 5.6mm i.d. polypropylene syringes. Poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith was modified with ethylenediamine to obtain the chelating material. The poly(butyl methacrylate-co-ethylene dimethacrylate) and poly(lauryl methacrylate-co-ethylene dimethacrylate) monoliths were first photografted with glycidyl methacrylate prior to functionalization with ethylenediamine. Alternatively, other chelating functionalities including poly(ethylene imines) varying in molecular weight and shape (linear and branched) as well as lysozyme were also attached to the monolithic supports. We found that the poly(glycidyl methacrylate-co-ethylene dimethacrylate) monolith functionalized with ethylenediamine exhibited the best chelating properties characterized with rapid adsorption and a capacity of 111.2mg/g (537μmol/g) for Pb(2+), 38.1mg/g (649μmol/g) for Ni(2+), 69.9mg/g (1100μmol/g) for Cu(2+), and 188.9mg/g (3633μmol/g) for Cr(3+). The very fast desorption was then achieved using 1.0mol/L HNO3 as the eluent. An enrichment factor of 300 was observed for metal ions adsorbed from solutions containing 2ppb of the metal. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Influence of Surface Treatments on the Bond Strength of Resin Cements to Monolithic Zirconia.

    Science.gov (United States)

    Elsaka, Shaymaa E

    To assess the influence of surface treatment on the microtensile bond strength (μTBS) of resin cements to monolithic zirconia materials. Two types of monolithic zirconia (Zenostar T [ZT] and Prettau Anterior [PA]) were evaluated. The specimens were assigned to three groups based on the surface treatment applied: group 1: control, assintered; group 2: sandblasted with 50-μm Al₂O₃; group 3: tribochemically silica sandblasted. Two types of resin cements (Multilink Speed [MS] and Multilink N [MN]) were applied to each group for evaluating the bond strength using the μTBS test. The fractured specimens were observed with a stereomicroscope and SEM. Surface roughness and topography of monolithic zirconia were examined after treatment. Data were analyzed using ANOVA and Tukey's test. A Weibull analysis was performed on the bond strength data. The bond strength was significantly affected by the surface treatment and the type of resin cement (p zirconia (p = 0.387). Surface treatment with tribochemical silica sandblasting revealed significantly higher bond strength (p zirconia was changed due to surface treatments. The surface treatment of monolithic zirconia with tribochemical silica sandblasting enhanced the bond strength between zirconia and resin cements. Resins cements containing adhesive phosphate monomer (APM, MS) provided higher bond strength to monolithic zirconia than non-APM (MN).

  11. Biomechanical three-dimensional finite element analysis of monolithic zirconia crown with different cement type

    Science.gov (United States)

    2015-01-01

    PURPOSE The objective of this study was to evaluate the influence of various cement types on the stress distribution in monolithic zirconia crowns under maximum bite force using the finite element analysis. MATERIALS AND METHODS The models of the prepared #46 crown (deep chamfer margin) were scanned and solid models composed of the monolithic zirconia crown, cement layer, and prepared tooth were produced using the computer-aided design technology and were subsequently translated into 3-dimensional finite element models. Four models were prepared according to different cement types (zinc phosphate, polycarboxylate, glass ionomer, and resin). A load of 700 N was applied vertically on the crowns (8 loading points). Maximum principal stress was determined. RESULTS Zinc phosphate cement had a greater stress concentration in the cement layer, while polycarboxylate cement had a greater stress concentration on the distal surface of the monolithic zirconia crown and abutment tooth. Resin cement and glass ionomer cement showed similar patterns, but resin cement showed a lower stress distribution on the lingual and mesial surface of the cement layer. CONCLUSION The test results indicate that the use of different luting agents that have various elastic moduli has an impact on the stress distribution of the monolithic zirconia crowns, cement layers, and abutment tooth. Resin cement is recommended for the luting agent of the monolithic zirconia crowns. PMID:26816578

  12. Trimethyl-β-cyclodextrin-encapsulated monolithic capillary columns: Preparation, characterization and chiral nano-LC application.

    Science.gov (United States)

    Ghanem, Ashraf; Adly, Frady G; Sokerik, Yasser; Antwi, Nana Yaa; Shenashen, Mohamed A; El-Safty, Sherif A

    2017-07-01

    Trimethylated-β-cyclodextrin (TM-β-CD) was encapsulated within several polymer monolithic capillary columns for reversed-phase chiral nano-liquid chromatography (nano-LC). The monolithic phases were prepared using the one-pot in situ copolymerization of ethylene glycol dimethacrylate (EDMA), glycidyl methacrylate (GMA) monomers and 1-propanol, 1,4-butanediol as progenic solvents in presence of TM-β-CD solution within fused silica capillaries (150µm I.D.). The obtained chiral monolithic stationery phases were characterized by scanning electron microscopy (SEM), N 2 adsorption/desorption isotherms, wide angle x-ray diffraction (WAXRD), thermogravimetric analysis (TGA) and differential thermal analysis (DTA). The materials characterization demonstrated that monolithic phases with higher concentration of TM-β-CD have relatively larger surface area, smaller pore size and larger total pore volume compared to those with lower concentration TM-β-CD. The prepared columns were tested for their enantioseparation efficiency of a range of racemic pharmaceuticals. The screening results demonstrated the potential of functionalizing polymer monolithic stationary phases with TM-β-CD using the in situ encapsulation approach. Crown Copyright © 2016. Published by Elsevier B.V. All rights reserved.

  13. [Preparation and application of mixed-mode capillary polymer monolithic column].

    Science.gov (United States)

    Dou, Abo; Zou, Cunjie; Shan, Yuanhong; Shi, Xianzhe; Xu, Guowang

    2014-05-01

    Based on the diversity of the retention mechanism, mixed-mode capillary monolithic columns have broad application prospect. In this work, a novel capillary polymer monolithic column was prepared with [2-(methacryloyloxy) ethyl] dimethyl-(3-sulfopropyl) ammonium hydroxide (SPE) as monomer, ethylene dimethacrylate (EDMA) as crosslinking agent, azobisisobutyronitrile (AIBN) as initiator and butylalcohol/1, 4-butanediol/water as ternary porogens. Under the optimized reaction conditions including the proportion of monomer and porogens, amount of initiator, reaction temperature and polymerization time, the monolithic column showed good mechanical strength up to 10 MPa, high permeability of 2. 17 x 10(-14) m2 and good repeatability. The peak area RSDs of column-to-column and batch-to-batch reproducibility were 1.0% and 4.6%, respectively. Finally, the capillary monolithic column was evaluated with polar and non-polar test mixtures. It showed hydrophilic interaction under high organic phase while hydrophobic interaction under low organic phase, indicating it a mixed-mode monolithic column.

  14. Effect of pore size on performance of monolithic tube chromatography of large biomolecules.

    Science.gov (United States)

    Podgornik, Ales; Hamachi, Masataka; Isakari, Yu; Yoshimoto, Noriko; Yamamoto, Shuichi

    2017-11-01

    Effect of pore size on the performance of ion-exchange monolith tube chromatography of large biomolecules was investigated. Radial flow 1 mL polymer based monolith tubes of different pore sizes (1.5, 2, and 6 μm) were tested with model samples such as 20 mer poly T-DNA, basic proteins, and acidic proteins (molecular weight 14 000-670 000). Pressure drop, pH transient, the number of binding site, dynamic binding capacity, and peak width were examined. Pressure drop-flow rate curves and dynamic binding capacity values were well correlated with the nominal pore size. While duration of the pH transient curves depends on the pore size, it was found that pH duration normalized on estimated surface area was constant, indicating that the ligand density is the same. This was also confirmed by the constant number of binding site values being independent of pore size. The peak width values were similar to those for axial flow monolith chromatography. These results showed that it is easy to scale up axial flow monolith chromatography to radial flow monolith tube chromatography by choosing the right pore size in terms of the pressure drop and capacity. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. Towards high capacity latex-coated porous polymer monoliths as ion-exchange stationary phases.

    Science.gov (United States)

    Hutchinson, Joseph P; Hilder, Emily F; Shellie, Robert A; Smith, Jason A; Haddad, Paul R

    2006-02-01

    The preparation of high capacity agglomerated monolithic ion-exchangers for capillary ion chromatography is described. Post-modification of reactive monoliths was investigated as an alternative to co-polymerisation of a suitable functional monomer with an overarching goal of increasing ion-exchange capacity. Direct sulfonation of poly styrene-co-divinyl benzene monoliths using concentrated sulfuric acid or chlorosulfonic acid was unsuccessful even for monoliths containing as low as 8% crosslinker. In contrast, chemical transformation of reactive monoliths containing glycidyl methacrylate was used to increase the ion-exchange capacity by up to more than thirty-fold with ion exchange capacities of 14-29 microequiv g(-1) achieved. Three different reactions were considered, including reaction with 4-hydroxybenenesulfonic acid under basic conditions; reaction with thiobenzoic acid followed by transformation to a reactive thiol and the subsequent oxidation to the sulfonic acid; and direct sulfonation with sodium sulfite. Of these, the reaction with sodium sulfite resulted in the most significant increase in the capacity and the best separation performance. In the isocratic mode separation efficiencies of over 13,500 plates m(-1) were observed (for iodate). The separation of seven inorganic anions was also demonstrated using a hydroxide gradient.

  16. High-resolution digital elevation models from single-pass TanDEM-X interferometry over mountainous regions: A case study of Inylchek Glacier, Central Asia

    Science.gov (United States)

    Neelmeijer, Julia; Motagh, Mahdi; Bookhagen, Bodo

    2017-08-01

    This study demonstrates the potential of using single-pass TanDEM-X (TDX) radar imagery to analyse inter- and intra-annual glacier changes in mountainous terrain. Based on SAR images acquired in February 2012, March 2013 and November 2013 over the Inylchek Glacier, Kyrgyzstan, we discuss in detail the processing steps required to generate three reliable digital elevation models (DEMs) with a spatial resolution of 10 m that can be used for glacial mass balance studies. We describe the interferometric processing steps and the influence of a priori elevation information that is required to model long-wavelength topographic effects. We also focus on DEM alignment to allow optimal DEM comparisons and on the effects of radar signal penetration on ice and snow surface elevations. We finally compare glacier elevation changes between the three TDX DEMs and the C-band shuttle radar topography mission (SRTM) DEM from February 2000. We introduce a new approach for glacier elevation change calculations that depends on the elevation and slope of the terrain. We highlight the superior quality of the TDX DEMs compared to the SRTM DEM, describe remaining DEM uncertainties and discuss the limitations that arise due to the side-looking nature of the radar sensor.

  17. Estimating central tendency from a single spot measure: A closed-form solution for lognormally distributed biomarker data for risk assessment at the individual level.

    Science.gov (United States)

    Pleil, Joachim D; Sobus, Jon R

    2016-01-01

    Exposure-based risk assessment employs large cross-sectional data sets of environmental and biomarker measurements to predict population statistics for adverse health outcomes. The underlying assumption is that long-term (many years) latency health problems including cancer, autoimmune and cardiovascular disease, diabetes, and asthma are triggered by lifetime exposures to environmental stressors that interact with the genome. The aim of this study was to develop a specific predictive method that provides the statistical parameters for chronic exposure at the individual level based upon a single spot measurement and knowledge of global summary statistics as derived from large data sets. This is a profound shift in exposure and health statistics in that it begins to answer the question "How large is my personal risk?" rather than just providing an overall population-based estimate. This approach also holds value for interpreting exposure-based risks for small groups of individuals within a community in comparison to random individuals from the general population.

  18. Use of single photon emission computed tomography and magnetic resonance to evaluate central nervous system involvement in patients with juvenile systemic lupus erythematosus

    Directory of Open Access Journals (Sweden)

    Prismich G.

    2002-01-01

    Full Text Available The objective of the present study was to identify the single photon emission computed tomography (SPECT and magnetic resonance (MR findings in juvenile systemic lupus erythematosus (JSLE patients with CNS involvement and to try to correlate them with neurological clinical history data and neurological clinical examination. Nineteen patients with JSLE (16 girls and 3 boys, mean age at onset 9.2 years were submitted to neurological examination, electroencephalography, cerebrospinal fluid analysis, SPECT and MR. All the evaluations were made separately within a period of 15 days. SPECT and MR findings were analyzed independently by two radiologists. Electroencephalography and cerebrospinal fluid analysis revealed no relevant alterations. Ten of 19 patients (53% presented neurological abnormalities including present or past neurological clinical history (8/19, 42%, abnormal neurological clinical examination (5/19, 26%, and abnormal SPECT or MR (8/19, 42% and 3/19, 16%, respectively. The most common changes in SPECT were cerebral hypoperfusion and heterogeneous distribution of blood flow. The most common abnormalities in MR were leukomalacia and diffuse alterations of white matter. There was a correlation between SPECT and MR (P<0.05. We conclude that SPECT and MR are complementary and useful exams in the evaluation of neurological involvement of lupus.

  19. Physical properties of monolithic U8 wt.%-Mo

    Science.gov (United States)

    Hengstler, R. M.; Beck, L.; Breitkreutz, H.; Jarousse, C.; Jungwirth, R.; Petry, W.; Schmid, W.; Schneider, J.; Wieschalla, N.

    2010-07-01

    As a possible high density fuel for research reactors, monolithic U8 wt.%-Mo ("U8Mo") was examined with regard to its structural, thermal and electric properties. X-ray diffraction by the Bragg-Brentano method was used to reveal the tetragonal lattice structure of rolled U8Mo. The specific heat capacity of cast U8Mo was determined by differential scanning calorimetry, its thermal diffusivity was measured by the laser flash method and its mass density by Archimedes' principle. From these results, the thermal conductivity of U8Mo in the temperature range from 40 °C to 250 °C was calculated; in the measured temperature range, it is in good accordance with literature data for UMo with 8 and 9 wt.% Mo, is higher than for 10 wt.% Mo and lower than for 5 wt.% Mo. The electric conductivity of rolled and cast U8Mo was measured by a four-wire method and the electron based part of the thermal conductivity calculated by the Wiedemann-Frantz law. Rolled and cast U8Mo was irradiated at about 150 °C with 80 MeV 127I ions to receive the same iodine ion density in the damage peak region as the fission product density in the fuel of a typical high flux reactor after the targeted nuclear burn-up. XRD analysis of irradiated U8Mo showed a change of the lattice parameters as well as the creation of UO 2 in the superficial sample regions; however, a phase change by irradiation was not observed. The determination of the electron based part of the thermal conductivity of the irradiated samples failed due to high measurement errors which are caused by the low thickness of the damage region in the ion irradiated samples.

  20. Fabrication and characterization of nanotemplated carbon monolithic material.

    Science.gov (United States)

    He, Xiaoyun; Nesterenko, Ekaterina P; Nesterenko, Pavel N; Brabazon, Dermot; Zhou, Lin; Glennon, Jeremy D; Luong, John H T; Paull, Brett

    2013-09-11

    A novel hierarchical nanotemplated carbon monolithic rod (NTCM) was prepared using a novel facile nanotemplating approach. The NTCM was obtained using C60-fullerene modified silica gels as hard templates, which were embedded in a phenolic resin containing a metal catalyst for localized graphitization, followed by bulk carbonization, and template and catalyst removal. TEM, SEM, and BET measurements revealed that NTCM possessed an integrated open hierarchical porous structure, with a trimodal pore distribution. This porous material also possessed a high mesopore volume and narrow mesopore size distribution. During the course of carbonization, the C60 conjugated to aminated silica was partly decomposed, leading to the formation of micropores. The Raman signature of NTCM was very similar to that of multiwalled carbon nanotubes as exemplified by three major peaks as commonly observed for other carbon materials, i.e., the sp3 and sp2 carbon phases coexisted in the sample. Surface area measurements were obtained using both nitrogen adsorption/desorption isotherms (BET) and with a methylene blue binding assay, with BET results showing the NTCM material possessed an average specific surface area of 435 m2 g(-1), compared to an area of 372 m2 g(-1) obtained using the methylene blue assay. Electrochemical studies using NTCM modified glassy carbon or boron doped diamond (BDD) electrodes displayed quasi-reversible oxidation/reduction with ferricyanide. In addition, the BDD electrode modified with NTCM was able to detect hydrogen peroxide with a detection limit of below 300 nM, whereas the pristine BDD electrode was not responsive to this target compound.