WorldWideScience

Sample records for single meteorological tower

  1. Kaiseraugst nuclear power station: meteorological effects of the cooling towers

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Considerations of water conservation persuaded the German Government in 1971 not to allow the use of the Aar and Rhine for direct cooling of nuclear power stations. The criticism is often made that the Kaiseraugst cooling towers were built without full consideration of the resulting meteorological effects. The criticism is considered unjustified because the Federal Cooling Tower Commission considered all the relevant aspects before making its recommendations in 1972. Test results and other considerations show that the effect of the kaiseraugst cooling towers on meteorological and climatic conditions is indeed minimal and details are given. (P.G.R.)

  2. GPM GROUND VALIDATION METEOROLOGICAL TOWER ENVIRONMENT CANADA GCPEX V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GPM Ground Validation Meteorological Tower Environment Canada GCPEx dataset provides temperature, relative humidity, 10 m winds, pressure and solar radiation...

  3. BOREAS TF-3 NSA-OBS Tower Flux, Meteorological, and Soil Temperature Data

    Science.gov (United States)

    Wofsy, Steven; Sutton, Doug; Goulden, Mike; Hall, Forrest G. (Editor); Huemmrich, Karl (Editor)

    2000-01-01

    The BOReal Ecosystem-Atmosphere Study Tower Flux (BOREAS TF-3) team collected tower flux, surface meteorological, and soil temperature data at the BOREAS Northern Study Area-Old Black Spruce (NSA-OBS) site continuously from the March 1994 through October 1996. The data are available in tabular ASCII files.

  4. Average wind statistics for SRP area meteorological towers

    International Nuclear Information System (INIS)

    Laurinat, J.E.

    1987-01-01

    A quality assured set of average wind Statistics for the seven SRP area meteorological towers has been calculated for the five-year period 1982--1986 at the request of DOE/SR. A Similar set of statistics was previously compiled for the years 1975-- 1979. The updated wind statistics will replace the old statistics as the meteorological input for calculating atmospheric radionuclide doses from stack releases, and will be used in the annual environmental report. This report details the methods used to average the wind statistics and to screen out bad measurements and presents wind roses generated by the averaged statistics

  5. The Quality Control Algorithms Used in the Creation of NASA Kennedy Space Center Lightning Protection System Towers Meteorological Database

    Science.gov (United States)

    Orcutt, John M.; Brenton, James C.

    2016-01-01

    An accurate database of meteorological data is essential for designing any aerospace vehicle and for preparing launch commit criteria. Meteorological instrumentation were recently placed on the three Lightning Protection System (LPS) towers at Kennedy Space Center (KSC) launch complex 39B (LC-39B), which provide a unique meteorological dataset existing at the launch complex over an extensive altitude range. Data records of temperature, dew point, relative humidity, wind speed, and wind direction are produced at 40, 78, 116, and 139 m at each tower. The Marshall Space Flight Center Natural Environments Branch (EV44) received an archive that consists of one-minute averaged measurements for the period of record of January 2011 - April 2015. However, before the received database could be used EV44 needed to remove any erroneous data from within the database through a comprehensive quality control (QC) process. The QC process applied to the LPS towers' meteorological data is similar to other QC processes developed by EV44, which were used in the creation of meteorological databases for other towers at KSC. The QC process utilized in this study has been modified specifically for use with the LPS tower database. The QC process first includes a check of each individual sensor. This check includes removing any unrealistic data and checking the temporal consistency of each variable. Next, data from all three sensors at each height are checked against each other, checked against climatology, and checked for sensors that erroneously report a constant value. Then, a vertical consistency check of each variable at each tower is completed. Last, the upwind sensor at each level is selected to minimize the influence of the towers and other structures at LC-39B on the measurements. The selection process for the upwind sensor implemented a study of tower-induced turbulence. This paper describes in detail the QC process, QC results, and the attributes of the LPS towers meteorological

  6. The Quality Control Algorithms Used in the Process of Creating the NASA Kennedy Space Center Lightning Protection System Towers Meteorological Database

    Science.gov (United States)

    Orcutt, John M.; Brenton, James C.

    2016-01-01

    The methodology and the results of the quality control (QC) process of the meteorological data from the Lightning Protection System (LPS) towers located at Kennedy Space Center (KSC) launch complex 39B (LC-39B) are documented in this paper. Meteorological data are used to design a launch vehicle, determine operational constraints, and to apply defined constraints on day-of-launch (DOL). In order to properly accomplish these tasks, a representative climatological database of meteorological records is needed because the database needs to represent the climate the vehicle will encounter. Numerous meteorological measurement towers exist at KSC; however, the engineering tasks need measurements at specific heights, some of which can only be provided by a few towers. Other than the LPS towers, Tower 313 is the only tower that provides observations up to 150 m. This tower is located approximately 3.5 km from LC-39B. In addition, data need to be QC'ed to remove erroneous reports that could pollute the results of an engineering analysis, mislead the development of operational constraints, or provide a false image of the atmosphere at the tower's location.

  7. WJBF TV tower meteorological database for the ERAD Code-1993

    International Nuclear Information System (INIS)

    Weber, A.H.

    1996-07-01

    The Explosive Release Atmospheric Dispersion (ERAD) model (Boughton and DeLaurentis 1992) is a three-dimensional numerical model for simulating atmospheric transport and dispersion. The ERAD code is particularly adept at handling explosive releases into the atmosphere and is being used by the Materials and Accountability Department at the Savannah River Site (SRS) to provide risk estimates. The Environmental Technology Section (ETS) was asked to provide meteorological data to be used for applying ERAD to some site facilities. The ERAD model requires a vertical profile of meteorological measurements. The 1993 data from the WJBF-TV tower has been processed and provided for this purpose. This document describes the steps taken to prepare and format the database

  8. LBA-ECO CD-04 Meteorological and Flux Data, km 83 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — Tower flux measurements of carbon dioxide,water vapor, heat, and meteorological variables were obtained at the Tapajos National Forest, km 83 site, Santarem, Para,...

  9. Modelling regional scale surface fluxes, meteorology and CO2 mixing ratios for the Cabauw tower in the Netherlands

    NARCIS (Netherlands)

    Tolk, L.F.; Peters, W.; Meesters, A.G.C.A.; Groenendijk, M.; Vermeulen, A.T.; Steeneveld, G.J.; Dolman, A.J.

    2009-01-01

    We simulated meteorology and atmospheric CO2 transport over the Netherlands with the mesoscale model RAMS-Leaf3 coupled to the biospheric CO2 flux model 5PM. The results were compared with meteorological and CO2 observations, with emphasis on the tall tower of Cabauw. An analysis of the coupled

  10. Airborne plutonium-239 and americium-241 concentrations measured from the 125-meter Hanford Meteorological Tower

    International Nuclear Information System (INIS)

    Sehmel, G.A.

    1978-01-01

    Airborne plutonium-239 and americium-241 concentrations and fluxes were measured at six heights from 1.9 to 122 m on the Hanford meteorological tower. The data show that plutonium-239 was transported on nonrespirable and small particles at all heights. Airborne americium-241 concentrations on small particles were maximum at the 91 m height

  11. Legionnaires' disease from a cooling tower in a community outbreak in Lidköping, Sweden- epidemiological, environmental and microbiological investigation supported by meteorological modelling.

    Science.gov (United States)

    Ulleryd, Peter; Hugosson, Anna; Allestam, Görel; Bernander, Sverker; Claesson, Berndt E B; Eilertz, Ingrid; Hagaeus, Anne-Christine; Hjorth, Martin; Johansson, Agneta; de Jong, Birgitta; Lindqvist, Anna; Nolskog, Peter; Svensson, Nils

    2012-11-21

    An outbreak of Legionnaires' Disease took place in the Swedish town Lidköping on Lake Vänern in August 2004 and the number of pneumonia cases at the local hospital increased markedly. As soon as the first patients were diagnosed, health care providers were informed and an outbreak investigation was launched. Classical epidemiological investigation, diagnostic tests, environmental analyses, epidemiological typing and meteorological methods. Thirty-two cases were found. The median age was 62 years (range 36 - 88) and 22 (69%) were males. No common indoor exposure was found. Legionella pneumophila serogroup 1 was found at two industries, each with two cooling towers. In one cooling tower exceptionally high concentrations, 1.2 × 109 cfu/L, were found. Smaller amounts were also found in the other tower of the first industry and in one tower of the second plant. Sero- and genotyping of isolated L. pneumophila serogroup 1 from three patients and epidemiologically suspected environmental strains supported the cooling tower with the high concentration as the source. In all, two L. pneumophila strains were isolated from three culture confirmed cases and both these strains were detected in the cooling tower, but one strain in another cooling tower as well. Meteorological modelling demonstrated probable spread from the most suspected cooling tower towards the town centre and the precise location of four cases that were stray visitors to Lidköping. Classical epidemiological, environmental and microbiological investigation of an LD outbreak can be supported by meteorological modelling methods.The broad competence and cooperation capabilities in the investigation team from different authorities were of paramount importance in stopping this outbreak.

  12. Legionnaires’ disease from a cooling tower in a community outbreak in Lidköping, Sweden- epidemiological, environmental and microbiological investigation supported by meteorological modelling

    Science.gov (United States)

    2012-01-01

    Background An outbreak of Legionnaires’ Disease took place in the Swedish town Lidköping on Lake Vänern in August 2004 and the number of pneumonia cases at the local hospital increased markedly. As soon as the first patients were diagnosed, health care providers were informed and an outbreak investigation was launched. Methods Classical epidemiological investigation, diagnostic tests, environmental analyses, epidemiological typing and meteorological methods. Results Thirty-two cases were found. The median age was 62 years (range 36 – 88) and 22 (69%) were males. No common indoor exposure was found. Legionella pneumophila serogroup 1 was found at two industries, each with two cooling towers. In one cooling tower exceptionally high concentrations, 1.2 × 109 cfu/L, were found. Smaller amounts were also found in the other tower of the first industry and in one tower of the second plant. Sero- and genotyping of isolated L. pneumophila serogroup 1 from three patients and epidemiologically suspected environmental strains supported the cooling tower with the high concentration as the source. In all, two L. pneumophila strains were isolated from three culture confirmed cases and both these strains were detected in the cooling tower, but one strain in another cooling tower as well. Meteorological modelling demonstrated probable spread from the most suspected cooling tower towards the town centre and the precise location of four cases that were stray visitors to Lidköping. Conclusions Classical epidemiological, environmental and microbiological investigation of an LD outbreak can be supported by meteorological modelling methods. The broad competence and cooperation capabilities in the investigation team from different authorities were of paramount importance in stopping this outbreak. PMID:23171054

  13. Legionnaires’ disease from a cooling tower in a community outbreak in Lidköping, Sweden- epidemiological, environmental and microbiological investigation supported by meteorological modelling

    Directory of Open Access Journals (Sweden)

    Ulleryd Peter

    2012-11-01

    Full Text Available Abstract Background An outbreak of Legionnaires’ Disease took place in the Swedish town Lidköping on Lake Vänern in August 2004 and the number of pneumonia cases at the local hospital increased markedly. As soon as the first patients were diagnosed, health care providers were informed and an outbreak investigation was launched. Methods Classical epidemiological investigation, diagnostic tests, environmental analyses, epidemiological typing and meteorological methods. Results Thirty-two cases were found. The median age was 62 years (range 36 – 88 and 22 (69% were males. No common indoor exposure was found. Legionella pneumophila serogroup 1 was found at two industries, each with two cooling towers. In one cooling tower exceptionally high concentrations, 1.2 × 109 cfu/L, were found. Smaller amounts were also found in the other tower of the first industry and in one tower of the second plant. Sero- and genotyping of isolated L. pneumophila serogroup 1 from three patients and epidemiologically suspected environmental strains supported the cooling tower with the high concentration as the source. In all, two L. pneumophila strains were isolated from three culture confirmed cases and both these strains were detected in the cooling tower, but one strain in another cooling tower as well. Meteorological modelling demonstrated probable spread from the most suspected cooling tower towards the town centre and the precise location of four cases that were stray visitors to Lidköping. Conclusions Classical epidemiological, environmental and microbiological investigation of an LD outbreak can be supported by meteorological modelling methods. The broad competence and cooperation capabilities in the investigation team from different authorities were of paramount importance in stopping this outbreak.

  14. BOREAS TF-10 NSA-Fen Tower Flux and Meteorological Data

    Science.gov (United States)

    McCaughey, J. Harry; Hall, Forrest G. (Editor); Huemmrich, Karl (Editor); Jelinski, Dennis E.

    2000-01-01

    The BOREAS TF-10 team collected tower flux and meteorological data at two sites, a fen and a young jack pine forest, near Thompson, Manitoba, Canada, as part of BOREAS. A preliminary data set was assembled in August 1993 while field testing the instrument packages, and at both sites data were collected from 15-Aug to 31-Aug. The main experimental period was in 1994, when continuous data were collected from 08-Apr to 23-Sep at the fen site. A very limited experiment was run in the spring/ summer of 1995, when the fen site tower was operated from 08-Apr to 14-Jun in support of a hydrology experiment in an adjoining feeder basin. Upon examination of the 1994 data set, it became clear that the behavior of the heat, water, and carbon dioxide fluxes throughout the whole growing season was an important scientific question, and that the 1994 data record was not sufficiently long to capture the character of the seasonal behavior of the fluxes. Thus, the fen site was operated in 1996 in order to collect data from spring melt to autumn freeze-up. Data were collected from 29-Apr to 05-Nov at the fen site. All variables are presented as 30-minute averages. The data are stored in tabular ASCII files.

  15. Evaluation of Tower Shadowing on Anemometer Measurements at Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, David Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-06-14

    The objective of this study is to evaluate the effect of tower shadowing from the meteorology towers at LANL during 2014. This study is in response to the Department of Energy Meteorological Coordinating Council visit in 2015 that recommended an evaluation of any biases in the wind data introduced by the tower and boom alignment at all meteorology towers.

  16. Potential weather modification caused by waste heat release from large dry cooling towers

    International Nuclear Information System (INIS)

    Lee, J.

    1979-01-01

    A numerical model of a cooling tower plume is employed to study the possible atmospheric effects of thermal plumes from natural draft dry cooling towers. Calculations are performed for both single and multiple towers, each of which can dissipate the waste heat from a nominal 1000 MWe power generating unit, and the results are compared with those for wet cooling towers associated with plants of the same generating capacity. Dry cooling tower plumes are found to have a higher potential for inducing convective clouds than wet cooling tower plumes, under most summertime meteorological conditions. This is due to the fact that both the sensible heat and momentum fluxes from a dry tower in summer are approximately one order of magnitude larger than those from a wet cooling tower

  17. Measurements at cooling tower plumes. Part 3. Three-dimensional measurements at cooling tower plumes

    International Nuclear Information System (INIS)

    Fortak, H.

    An extended field experiment is described in which cooling tower plumes were studied by means of three-dimensional in situ measurements. The goal was to obtain input data for numerical models of cooling tower plumes. Of special interest were data for testing or developing assumptions for sub-grid parametrizations. Utilizing modern systems for high-resolution aerology and small aircraft, four measuring campaigns were conducted: two campaigns (1974) at the cooling towers of the RWE power station Neurath and also two (1975) at the single cooling tower of the RWE power station Meppen. Because of the broad spectrum of weather situations it can be assumed that the results are representative with regard to the interrelationship between structure of cooling tower plume and large-scale meteorological situation. A large number of flights with a powered glider crossing the plumes on orthogonal tracks was performed. All flights showed that the plume could be identified up to large downwind distances by discontinuous jumps of temperature and vapor pressure. Therefore, a definite geometry of the plume could always be defined. In all cross sections a vertical circulation could be observed. At the boundary, which could be defined by the mentioned jumps of temperature and vapor pressure, a maximum of downward vertical motion could be observed in most cases. Entrainment along the boundary of a cross section seems to be very small, except at the lower part of the plume. There, the mass entrainment is maximum and is responsible for plume rise as well as for enlargement of the cross section. The visible part of the plume (cloud) was only a small fraction of the whole plume. High-resolution aerology is necessary in order to explain the structure and behavior of such plumes. This is especially the case in investigations regarding the dynamic break-through of temperature inversions. Such cases were observed frequently under various meteorological conditions and are described

  18. METRODOS: Meteorological preprocessor chain

    DEFF Research Database (Denmark)

    Astrup, P.; Mikkelsen, T.; Deme, S.

    2001-01-01

    The METRODOS meteorological preprocessor chain combines measured tower data and coarse grid numerical weather prediction (NWP) data with local scale flow models and similarity scaling to give high resolution approximations of the meteorological situation. Based on available wind velocity and dire...

  19. Development of adequate meteorological monitoring standards for safety analysis of nuclear facilities

    International Nuclear Information System (INIS)

    Alp, E.; Lewis, P.J.

    1985-09-01

    The aim of this report is to identify what constitutes adequate meteorological information for airborne dispersion calculations in case of releases from nuclear facilities during 'normal operation', 'design postulated accidents', and 'emergency situations'. The models used for estimating downwind dispersion are reviewed, including short-range simple terrain, short-range complex terrain and medium to long range models with emphasis on Lagrangian models. The meteorogolical input parameters required for running these models are identified. The methods by which these parameters may be obtained from raw meteorological data are then considered. Emphasis is placed on well-tried and recommended methods rather than those which are currently being developed and lack long-term field tests. The meteorological data required to calculate the parameters that are in turn input to dispersion calculation methods can be obtained mainly from tower measurements. Recommended tower height is 50 m, with two levels of instruments (10 and 50 m) for wind speed, wind direction and temperature. Data for precipitation and solar radiation, that may be required under certain conditions and for special calculations, may be estimated from nearby representative weather stations (if available). For simple terrain, a single tower is sufficient. For complex terrain, such as coastal regions, two towers are desirable for accurate characterization of the turbulence regime in the vicinity of a release site. The report provides the necessary accuracy specifications for instruments required for the meteorological measurements. Data monitoring and recording, maintenance, quality control and assurance are also discussed. Error propagation analyses are recommended to determine the full implications of instrument accuracies on the accuracy of dispersion model predictions. 82 refs

  20. Operative meteorological data base in Forsmark

    International Nuclear Information System (INIS)

    Appelgren, A.; Hallberg, B.; Nordlinder, S.

    1990-01-01

    This report describes how data collected during a field measurement campaign were analysed and compiled to create a data base for operative use. The data base gives information about the wind and the atmospheric stability at five locations around the Forsmark nuclear power plant. In the measurement campaign, sodar systems and a 100 m high tower at Forsmark were used. Temperature, wind speed and wind direction were measured by sensors on the tower, while wind speed and direction, and the standard deviation of the vertical wind, were monitored by the sodar systems. This gave meteorological data from several heights. At Forsmark, the temperature difference and the wind speed from the tower were used to determine the atmospheric stability. At the sodar locations, the stability was deduced by employing a scheme which considered the season, the time of day, the wind direction and the wind speed. To create the operative data base, the wind speeds and wind directions, respectively, from two locations at the time were correlated. A code for graphical and numerical presentation of the data from the data base was developed. A special system of warnings was included, featuring notification about phenomena such as sea breeze, warnings about large variation in the wind conditions within the area, and warnings for situations in which the meteorological conditions make the results from the atmospheric dispersion calculations uncertain. This feature was implemented to alert the user to the fact that ordinary dispersion and dose calculations, using meteorological data from a single point, might give erroneous results. The operative data base and the presentation code were integrated with the dispersion and dose calculation code AIRPAC/EMMA, which is to be used in case of increased releases from nuclear power plants. The possibility to use the data from the operative data base in the dispersion calculations was investigated. It was found that a modification of AIRPAC/EMMA, in such a

  1. Numerical simulation of a cooling tower coupled with heat pump system associated with single house using TRNSYS

    International Nuclear Information System (INIS)

    Chargui, R.; Sammouda, H.; Farhat, A.

    2013-01-01

    Highlights: • We simulate a cooling tower coupled with heat pump system and a single zone using TRNSYS. • We examine the temperature of water inside the cooling tower and inside the single zone. • We study the temporal evolution of the all parameters for 4500 h operation in winter in Tunisia. - Abstract: The industrial cooling towers in Tunisia meet difficulties due to the poor coordination between the utility and process sectors. In this study, we will consider especially the vapor recovery of the wastewater from the industrial activity in south Tunisia. By using the heat pump for high capacity, the problem for vapor from wastewater may be resolved. The coupling for the cooling tower and the heat pump system is investigated by TRNSYS software. The system of cooling tower is also associated with a single zone which is related to heat exchangers. An optimization model for the operation of a cooling water system was developed that accounts for a cooling tower, and a network of pipelines and heat exchangers for heating a single house. This work is based on numerical studies; the cooling tower performance, the single house, the heat pump and the heat exchanger that are simulated using TRNSYS model. The circulation of cooling water system is assured by a counter flow. The evaluations of the cooling tower geometry and performances are based on an adaptive version of Merkel’s method witch integrated in TRNSYS. The results of optimization using TRNSYS are validated by several theoretical and experimental studies

  2. Tower Mesonetwork Climatology and Interactive Display Tool

    Science.gov (United States)

    Case, Jonathan L.; Bauman, William H., III

    2004-01-01

    Forecasters at the 45th Weather Squadron and Spaceflight Meteorology Group use data from the tower network over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to evaluate Launch Commit Criteria, and issue and verify forecasts for ground operations. Systematic biases in these parameters could adversely affect an analysis, forecast, or verification. Also, substantial geographical variations in temperature and wind speed can occur under specific wind directions. To address these concerns, the Applied Meteorology Unit (AMU) developed a climatology of temperatures and winds from the tower network, and identified the geographical variation and significant tower biases. The mesoclimate is largely driven by the complex land-water interfaces across KSC/CCAFS. Towers with close proximity to water typically had much warmer nocturnal temperatures and higher wind speeds throughout the year. The strongest nocturnal wind speeds occurred from October to March whereas the strongest mean daytime wind speeds occurred from February to May. These results of this project can be viewed by forecasters through an interactive graphical user interface developed by the AMU. The web-based interface includes graphical and map displays of mean, standard deviation, bias, and data availability for any combination of towers, variables, months, hours, and wind directions.

  3. Assessment of cooling tower impact

    International Nuclear Information System (INIS)

    1986-01-01

    This guideline describes the state of the art of the meteorological impact of wet cooling towers that are about 80 m to 170 m high, and have a waste heat power in the range of 1000 MW and 2500 MW. The physical processes occurring in the lowest layer of the atmosphere and their impact in the dispersion of cooling tower emissions are represented. On the basis of these facts, the impact on weather or climate in the vicinity of a high wet cooling tower is estimated. Thereby the results of the latest investigations (observations, measurements, and modeling) on the different locations of plants as well as their different power and construction types are taken into consideration. (orig.) [de

  4. Data from an instrumented navigational light tower off the Savanah River estuary

    International Nuclear Information System (INIS)

    Hayes, D.W.; Dicks, A.S.; Blanton, J.O.

    1978-01-01

    An oceanographic and meteorological instrumentation system operating on the Savannah Navigational Light Tower is providing synoptic information on ocean temperatures, currents, tides, and meteorological conditions. The Savannah Navigational Light Tower, an unmanned U.S. Coast Guard tower, is located about nine miles off Savannah Beach, Georgia, in about 16 m of water. The tower is currently instrumented to measure and record water temperatures from six depths, water velocities at two depts, tides, air temperature, barometric pressure, and wind speed and velocity at two heights. The outputs are currently being recorded every 10 minutes. These data aid in the interpretation of the processes governing pollutant transport in the Savannah River marine region and support other DOE funded programs in the southeastern United States. This past year, computer programs were written and are being tested for processing the raw data from the tower and for performing correlative analysis of the data

  5. Measurements on cooling tower plumes. Pt. 3

    International Nuclear Information System (INIS)

    Fortak, H.

    1975-11-01

    In this paper an extended field experiment is described in which cooling tower plumes were investigated by means of three-dimensional in situ measurements. The goal of this program was to obtain input data for numerical models of cooling tower plumes. Data for testing or developing assumptions for sub-grid parametrizations were of special interest. Utilizing modern systems for high-resolution aerology and small aircraft, four measuring campaigns were conducted: two campaigns (1974) at the cooling towers of the RWE power station at Neurath and also two (1975) at the single cooling tower of the RWE power station at Meppen. Because of the broad spectrum of weather situations, it can be assumed that the results are representative with regard to the interrelationship between the structure of cooling tower plumes and the large-scale meteorological situation. A large number of flights with a powered glider ASK 16 (more than 100 flight hours) crossing the plumes on orthogonal tracks was performed. All flights showed that the plume could be identified up to large downwind distances by discontinuous jumps of temperature and vapour pressure. Therefore a definite geometry of the plume could always be defined. In all cross sections a vertical circulation could be observed. At the plumes boundaries, which could be defined by the mentioned jumps of temperature and vapour pressure, a maximum of downward vertical motion was observed in most cases. Entrainment along the boundary of a cross section seems to be very small, except at the lower part of the plume. There, the mass entrainment is maximum and is responsible for plume rise as well as for enlargement of the cross section. The visible part of the plume (cloud) was only a small fraction of the whole plume. The discontinuities of temperature and vapour pressure show that the plume fills the space below the visible plume down to the ground. However, all effects decrease rapidly towards the ground. It turned out that high

  6. Overall analysis of meteorological information in the Daeduk nuclear complex

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Woo; Lee, Young Bok; Han, Moon Hee; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae [Korea Atomic Energy Res. Inst., Taejon (Korea, Republic of)

    1994-01-01

    Inspection and repair of tower structure and lift, instrument calibration have been done with DAS (data aquisition system) updating. Wind direction, wind speed, temperature, humidity at 67m, 27m, and 10m height and temperature, humidity, atmospheric pressure, solar radiation, precipitation, and visibility at surface have been measured and analyzed with statistical methods. Wireless data transmission to MIPS (Meteorological Information Processing System) has been done after collection in the DAS where enviromental assessment can be done by the developed simulation programs in both cases of normal operation and emergency. The meteorological data as the result of this project had been used to report `Environmental Impact Assessment of the Korean Multi-purpose Research Reactor` and {sup S}ite Selection of Meteorological Tower and Environment Impact Assessment of the Cooling Tower of the Korean Multi-purpose Research Reactor{sup .} (Author).

  7. BOREAS TF-10 NSA-YJP Tower Flux, Meteorological, and Porometry Data

    Science.gov (United States)

    McCaughey, J. Harry; Liblik, Laura; Hall, Forrest G. (Editor); Huemmrich, K. (Editor)

    2000-01-01

    The BOREAS TF-10 team collected tower flux and meteorological data at two sites, a fen and a young jack pine forest, near Thompson, Manitoba, Canada, as part of BOREAS. A preliminary data set was assembled in August 1993 while field testing the instrument packages, and at both sites data were collected from 15-Aug to 31-Aug. The main experimental period was in 1994, when continuous data were collected from the young jack pine site from 23-May to 20-Sep. Upon examination of the 1994 data set, it became clear that the behavior of the heat, water, and carbon dioxide fluxes throughout the whole growing season was an important scientific question, and that the 1994 data record was not sufficiently long to capture the character of the seasonal behavior of the fluxes. Thus, the young jack pine site was operated from 08-May to 07-Nov in 1996 in order to collect data from spring melt to autumn freeze-up. All variables are presented as 30-minute averages. Supporting data were also collected to describe the surface#s state and to provide the information, in association with the flux data, to build SVAT models. For the young jack pine site, these supporting data included stomatal conductance measurements. The data are stored in tabular ASCII files.

  8. The meteorological data acquisition system

    International Nuclear Information System (INIS)

    Bouharrour, S.; Thomas, P.

    1975-07-01

    The 200 m meteorological tower of the Karlsruhe Nuclear Research Center has been equipped with 45 instruments measuring the meteorological parameters near the ground level. Frequent inquiry of the instruments implies data acquisition with on-line data reduction. This task is fulfilled by some peripheral units controlled by a PDP-8/I. This report presents details of the hardware configuration and a short description of the software configuration of the meteorological data acquisition system. The report also serves as an instruction for maintenance and repair work to be carried out at the system. (orig.) [de

  9. Plant Vogtle cooling tower studies

    International Nuclear Information System (INIS)

    O'Steen, L.

    2000-01-01

    Intensive ground-based field studies of plumes from two large, natural-draft cooling towers were conducted in support of the MTI modeling effort. Panchromatic imagery, IR imagery, meteorological data, internal tower temperatures and plant power data were collected during the field studies. These data were used to evaluate plume simulations, plume radioactive transfer calculations and plume volume estimation algorithms used for power estimation. Results from six field studies indicate that a 3-D atmospheric model at sufficient spatial resolution can effectively simulate a cooling tower plume if the plume is of sufficient size and the ambient meteorology is known and steady. Small plumes and gusty wind conditions degrade the agreement between the simulated and observed plumes. Thermal radiance calculations based on the simulated plumes produced maximum IR temperatures (near tower exit) which were in good agreement with measured IR temperatures for the larger plumes. For the smaller plumes, the calculated IR temperature was lower than the measured temperature by several degrees. Variations in maximum IR plume temperature with decreasing power (one reactor was undergoing a shutdown process), were clearly observed in the IR imagery and seen in the simulations. These temperature changes agreed with those calculated from an overall tower energy and momentum balance. Plume volume estimates based on camcorder images at three look angles were typically 20--30 percent larger than the plume volumes derived from the simulations, although one estimate was twice the simulated volume. Volume overestimation is expected and will have to be accounted for to some degree if plume volume is to be a useful diagnostic quantity in power estimation. Volume estimation with MTI imagery will require a large, stable plume and two looks in the visible bands (5m GSD) along with a solar shadow

  10. Validation of the Dynamic Wake Meander model with focus on tower loads

    Science.gov (United States)

    Larsen, T. J.; Larsen, G. C.; Pedersen, M. M.; Enevoldsen, K.; Madsen, H. A.

    2017-05-01

    This paper presents a comparison between measured and simulated tower loads for the Danish offshore wind farm Nysted 2. Previously, only limited full scale experimental data containing tower load measurements have been published, and in many cases the measurements include only a limited range of wind speeds. In general, tower loads in wake conditions are very challenging to predict correctly in simulations. The Nysted project offers an improved insight to this field as six wind turbines located in the Nysted II wind farm have been instrumented to measure tower top and tower bottom moments. All recorded structural data have been organized in a database, which in addition contains relevant wind turbine SCADA data as well as relevant meteorological data - e.g. wind speed and wind direction - from an offshore mast located in the immediate vicinity of the wind farm. The database contains data from a period extending over a time span of more than 3 years. Based on the recorded data basic mechanisms driving the increased loading experienced by wind turbines operating in offshore wind farm conditions have been identified, characterized and modeled. The modeling is based on the Dynamic Wake Meandering (DWM) approach in combination with the state-of-the-art aeroelastic model HAWC2, and has previously as well as in this study shown good agreement with the measurements. The conclusions from the study have several parts. In general the tower bending and yaw loads show a good agreement between measurements and simulations. However, there are situations that are still difficult to match. One is tower loads of single-wake operation near rated ambient wind speed for single wake situations for spacing’s around 7-8D. A specific target of the study was to investigate whether the largest tower fatigue loads are associated with a certain downstream distance. This has been identified in both simulations and measurements, though a rather flat optimum is seen in the measurements.

  11. Technical procedures for implementation of meteorology/air quality site studies, Deaf Smith County site, Texas: Environmental Field Program: Preliminary draft

    International Nuclear Information System (INIS)

    1987-09-01

    This report describes The Technical Procedures that will be used to monitor air quality and meteorology. Topics include: high-volume filter handling; operation, maintenance, and calibration of the 10-M meteorological and air quality system; processing data from the 10-M meteorological tower; processing data from the 60-M meteorological tower; processing total suspended particulate filters and data from the high-volume air samplers; operation maintenance, and calibration of the 60-M meteorological and air quality system; and auditing the air quality system. 4 refs., 6 figs

  12. Real time quality control of meteorological data used in SRP's emergency response system

    International Nuclear Information System (INIS)

    Pendergast, M.M.

    1980-05-01

    The Savannah River Laboratory's WIND minicomputer system allows quick and accurate assessment of an accidental release at the Savannah River Plant using data from eight meteorological towers. The accuracy of the assessment is largely determined by the accuracy of the meteorological data; therefore quality control is important in an emergency response system. Real-time quality control of this data will be added to the WIND system to automatically identify inaccurate data. Currently, the system averages the measurements from the towers to minimize the influence of inaccurate data being used in calculations. The computer code used in the real-time quality control has been previously used to identify inaccurate measurements from the archived tower data

  13. Longitudinal Seismic Behavior of a Single-Tower Cable-Stayed Bridge Subjected to Near-Field Earthquakes

    Directory of Open Access Journals (Sweden)

    J. Yi

    2017-01-01

    Full Text Available Cable-stayed bridges are quite sensitive to large amplitude oscillations from earthquakes and seismic damage was observed for Shipshaw Bridge and Chi-Lu Bridge during past earthquakes. In order to investigate seismic damage of cable-stayed bridges, a 1 : 20 scale model of a single-tower cable-stayed bridge with A-shaped tower was designed, constructed, and tested on shake tables at Tongji University, China. One typical near-field ground motion was used to excite the model from low to high intensity. Test result showed that severe structural damage occurred at the tower of the model including parallel concrete cracks from bottom to nearly half height of the tower, concrete spalling, and exposed bars at top tower 0.2 m above the section where two skewed legs intersect. Posttest analysis was conducted and compared with test results. It is revealed that the numerical model was able to simulate the seismic damage of the test model by modeling nonlinearity of different components for cable-stayed bridges, namely, the tower, bents, superstructure, cables, and bearings. Numerical analysis also revealed that cable relaxation, which was detected during the test, had limited influence on the overall seismic response of the bridge with maximum error of 12%.

  14. Meteorological data summaries for the TFTR from March 1984 to February 1985

    International Nuclear Information System (INIS)

    Kolibal, J.; Ku, L.P.; Liew, S.L.; Pierce, C.

    1985-06-01

    This report reviews the first year of meteorological data gathered for the Tokamak Fusion Test Reactor (TFTR) at Princeton Plasma Physics Laboratory (PPPL) from March 1, 1984 to February 28, 1985. The meteorological station at TFTR is located at D-Site, to the east of the motor generator building as shown in Fig. 1. The station consists of a 60 m tower which is instrumented at 10, 30, and 60 m along with the associated equipment for data acquisition and logging. Instrumentation for the tower consists of measuring the temperature, wind speed, wind direction, dew point, and the standard deviation of the horizontal wind direction. The purpose of the station is to gather site specific meteorological data to assess atmospheric transport and dispersion for TFTR

  15. A Meso-Climatology Study of the High-Resolution Tower Network Over the Florida Spaceport

    Science.gov (United States)

    Case, Jonathan L.; Bauman, William H., III

    2004-01-01

    Forecasters at the US Air Force 45th Weather Squadron (45 WS) use wind and temperature data from the tower network over the Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS) to evaluate Launch Commit Criteria and to issue and verify temperature and wind advisories, watches, and warnings for ground operations. The Spaceflight Meteorology Group at the Johnson Space Center in Houston, TX also uses these data when issuing forecasts for shuttle landings at the KSC Shuttle Landing Facility. Systematic biases in these parameters at any of the towers could adversely affect an analysis, forecast, or verification for all of these operations. In addition, substantial geographical variations in temperature and wind speed can occur under specific wind directions. Therefore, the Applied Meteorology Unit (AMU), operated by ENSCO Inc., was tasked to develop a monthly and hourly climatology of temperatures and winds from the tower network, and identify the geographical variation, tower biases, and the magnitude of those biases. This paper presents a sub-set of results from a nine-year climatology of the KSC/CCAFS tower network, highlighting the geographical variations based on location, month, times of day, and specific wind direction regime. Section 2 provides a description of the tower mesonetwork and instrumentation characteristics. Section 3 presents the methodology used to construct the tower climatology including QC methods and data processing. The results of the tower climatology are presented in Section 4 and Section 5 summarizes the paper.

  16. Wind-induced response of CN-Tower: comparison of model and full scale

    International Nuclear Information System (INIS)

    Monbaliu, J.; Ruigrok, C.; Isyumov, N.

    1985-01-01

    The approximately 555-m high CN Communications Tower in Toronto has now been operational for nearly a decade. The action of wind on this tower was extensively tested at the Boundary Layer Wind Tunnel Laboratory during the design of the tower. This study provided information on the overall wind loads and responses of the structure, the action of wind on various components, and its effects on the tower performance including transmission quality. A program of monitoring and recording the wind induced response and various meteorological data was started in 1977. This paper presents some results of that program and makes comparisons with wind tunnel model data. (author)

  17. Industrial cooling tower design and operation in the moderate-continental climate conditions

    Directory of Open Access Journals (Sweden)

    Laković Mirjana S.

    2016-01-01

    Full Text Available A large number of producers offer a wide choice of various types of industrial cooling towers. Usually, a proper choice of pre-fabricated cooling tower satisfies end-user needs. However, if there are specific end-user requirements, it is necessary to design cooling tower according to those requirements. For the adhesive factory located in southern region of Serbia, 350 kW mechanical draught wet cooling tower was designed and built. Dimensioning of the cooling tower was done according to parameters of the ambient air, higher than the standard recommendations given in the literature. In this paper, the reasons for deviation from recommendations are given. The analysis of the cooling tower operation based on real meteorological parameters for 2015 is also shown in this paper. According to this analysis, cooling tower provides required water temperature in any season, and gives opportunity for energy savings in winter, with opportunity for heat capacity enlargement if production capacity is raised as it is planned in the factory.

  18. Induced draught circular cooling tower

    International Nuclear Information System (INIS)

    Blanquet, J.C.

    1980-01-01

    Induced draught atmospheric cooling towers are described, to wit those in which the circulation is by power fans. This technique with fans grouped together in the centre enables a single tower to be used and provides an excellent integration of the steam wreath into the atmosphere. This type of cooling tower has been chosen for fitting out two 900 MW units of the Chinon power station in France [fr

  19. Variations of starting conditions contribution to cooling tower plume predictions; Uticaj promene polaznih uslova na predvidjanje rasprostiranja perjanica rashladnih tornjeva nuklearne elektrane

    Energy Technology Data Exchange (ETDEWEB)

    Vehauc, A; Zaric, Z [Boris Kidric Institute of nuclear sciences, Vinca, Belgrade (Yugoslavia)

    1977-07-01

    The paper deals with quantitative contribution of variations of starting conditions to cooling tower plume predictions. The starting conditions are: plume velocity and temperature and concentration of water drops in the plume at the cooling tower outlet. For the same thermal discharge and meteorological conditions, starting conditions are given by characteristics of cooling towers. (author)

  20. BOREAS TF-06 SSA-YA Surface Energy Flux and Meteorological Data

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: Contains meteorology data collected at the SSA-YA tower flux site by the TF6 group. These data were reported at 10 minute intervals. The flux and ancillary...

  1. Effect of Concrete Creep on the displacement of single tower single cable plane Extradosed Cable-stayed Bridge

    Science.gov (United States)

    Shi, Jing-xian; Ran, Zhi-hong

    2018-03-01

    Extradossed Cable-stayed Bridge is both cable-stayed Bridge and Continuous rigid frame bridge mechanics feature, Beam is the main force components, cable is supplement.This article combined with a single tower and single cable plane Extradossed cable-stayed bridge in Yunnan, use different creep calculation models and analysis deflection caused by creep effects. The results showing that deflection caused by creep effect is smaller than the same span continuous rigid frame bridge, the value is about 2cm. On the other hand the deflection is increasing with ambient humidity decreases, therefore in the dry environment the calculation model is relatively large in the pre-camber. In the choice of RC creep model is significant in the dry areas.

  2. FLORIDA TOWER FOOTPRINT EXPERIMENTS

    Energy Technology Data Exchange (ETDEWEB)

    WATSON,T.B.; DIETZ, R.N.; WILKE, R.; HENDREY, G.; LEWIN, K.; NAGY, J.; LECLERC, M.

    2007-01-01

    The Florida Footprint experiments were a series of field programs in which perfluorocarbon tracers were released in different configurations centered on a flux tower to generate a data set that can be used to test transport and dispersion models. These models are used to determine the sources of the CO{sub 2} that cause the fluxes measured at eddy covariance towers. Experiments were conducted in a managed slash pine forest, 10 km northeast of Gainesville, Florida, in 2002, 2004, and 2006 and in atmospheric conditions that ranged from well mixed, to very stable, including the transition period between convective conditions at midday to stable conditions after sun set. There were a total of 15 experiments. The characteristics of the PFTs, details of sampling and analysis methods, quality control measures, and analytical statistics including confidence limits are presented. Details of the field programs including tracer release rates, tracer source configurations, and configuration of the samplers are discussed. The result of this experiment is a high quality, well documented tracer and meteorological data set that can be used to improve and validate canopy dispersion models.

  3. Hospital-acquired legionellosis originating from a cooling tower during a period of thermal inversion.

    Science.gov (United States)

    Engelhart, Steffen; Pleischl, Stefan; Lück, Christian; Marklein, Günter; Fischnaller, Edith; Martin, Sybille; Simon, Arne; Exner, Martin

    2008-07-01

    A case of hospital-acquired legionellosis occurred in a 75-year-old male patient who underwent surgery due to malignant melanoma. Legionellosis was proven by culture of Legionella pneumophila serogroup 1 from bronchoalveolar lavage (BAL) fluid. Being a chronic smoker the patient used to visit the sickroom balcony that was located about 90 m to the west of a hospital cooling tower. Routine cooling tower water samples drawn during the presumed incubation period revealed 1.0x10(4) CFU/100 ml (L. pneumophila serogroup 1). One of three isolates from the cooling tower water matched the patient's isolate by monoclonal antibody (mab)- and genotyping (sequence-based typing). Horizontal transport of cooling tower aerosols probably was favoured by meteorological conditions with thermal inversion. The case report stresses the importance of routine maintenance and microbiological control of hospital cooling towers.

  4. A system for real-time environmental assessment using an operational meteorological data base for dispersion calculations

    International Nuclear Information System (INIS)

    Appelgren, A.; Hallberg, B.; Nordlinder, S.; Salomonsson, S.

    1990-01-01

    A method for assessing the meteorological conditions on a local scale, about 20 km, around a specific site was developed, and applied to the area around the Forsmark nuclear power plant, situated on the coast about 100 km north of Stockholm. Meteorological data were collected, for an one-year period, from sensors in a tower and from a Sodar system at Forsmark. In addition, two Sodar systems were placed at several locations around the power plant, out to a distance of approximately 20 km. By statistical compiling, an operational data base was established, consisting of classes of wind speed, wind direction and atmospheric stability. The data from the remote sites were related to those from Forsmark. This gave the possibility to determine the variation of the meteorological conditions in time and space, using data from a single location only. The main objective of the Forsmark project was to identify and indicate situations in which the conditions for dispersion were difficult to model accurately when using measurements taken from a conventional tower, without knowledge of the influence of local mesoscale disturbances. Such could be e.g. sea breeze, large horizontal or vertical wind shear, terrain-induced flow patterns etc. The use of an operational data base, as described above, in connection with real-time dispersion models, such as AIRPAC/EMMA, will improve the performance of such models, as well as consequence analyses, in case of accidental releases from nuclear power plants or other industrial plants

  5. Cooling tower drift: comprehensive case study

    International Nuclear Information System (INIS)

    Laulainen, N.S.; Ulanski, S.L.

    1979-01-01

    A comprehensive experiment to study drift from mechanical drift cooling towers was conducted during June 1978 at the PG and E Pittsburg Power Plant. The data from this study will be used for validation of drift deposition models. Preliminary results show the effects of tower geometry and orientation with respect to the wind and to single- or two-tower operation. The effect of decreasing relative humidity during a test run can also be seen

  6. Cooling towers: denvironmental studies (citations from the engineering index data base). Report for 1970-August 1978

    International Nuclear Information System (INIS)

    Hundemann, A.S.

    1978-01-01

    Abstracts from worldwide research on thermal, meteorological, and ecological effects associated with cooling towers used primarily by fossil fuel and nuclear power plants are cited. Citations cover plume behavior studies, including measurement of airborne particulate concentration, and characterization and management of drift as well as noise pollution and salt deposition effects on vegetation. A few abstracts pertain to environmental effects from cooling towers used in wastewater treatment

  7. Meteorological safeguarding of nuclear power plant operation in Czechoslovakia

    International Nuclear Information System (INIS)

    Rak, J.; Skulec, S.

    1976-01-01

    A meteorological tower 200 m high has to be built for meteorological control of the operation of the A-1 nuclear power plant at Jaslovske Bohunice. This meteorological station will measure the physical properties of the lower layers of the atmosphere, carry out experimental verifications of the models of air pollution, investigate the effects of waste heat and waste water from the nuclear power plant on the microclimate, provide the theoretical processing of measured data with the aim of selecting the most favourable model for conditions prevailing in the Czechoslovak Socialist Republic, perform basic research of the physical properties of the ground and boundary layers of the atmosphere and the coordination of state-wide plans in the field of securing the operation of nuclear power plants with regard to meteorology. (Z.M.)

  8. Ocean breeze monitoring network at the Oyster Creek Nuclear Plant

    International Nuclear Information System (INIS)

    Heck, W.

    1987-01-01

    The Oyster Creek Nuclear Generating Station (OCNGS) is located in New Jersey 10 km west of the Atlantic Ocean. Routine meteorological monitoring at the station has consisted of a single meteorological tower 120 m high and instrumented at the 10-m, 46-m, and 116-m levels. An analysis of 5 yr of data from this tower showed the OCNGS is affected by an ocean breeze ∼ 1 day out of 4 during May through August. This suggested the need for meteorological monitoring in addition to the single met tower at OCNGS. As a result of the 1985 OCNGS meteorological monitoring study, GPU Nuclear established an ocean breeze monitoring network in the fall of 1986. It is a permanent part of OCNGS meteorological monitoring and consists of the same sites as used in the 1985 field study. Meteorological towers are located at the ocean site, the inland site, and at OCNGS. The ocean tower is 13 m (43 ft) high, the inland tower 10 m (33 ft), and the OCNGS tower 116 m (380 ft). Wind speed, wind direction, and temperature are measured on each tower; delta-temperature is also measured on the main tower. The instruments are calibrated in the spring, summer, and fall. The network is operated and maintained by GPU Nuclear Environmental Controls. The ocean breeze monitoring network and meteorological information system forms the basis for including the effects of the ocean breeze in OCNGS emergency off-site dose assessment

  9. Influence of the Meteorology Mast on a Cup Anemometer

    DEFF Research Database (Denmark)

    Hansen, Martin O. L.; Pedersen, B.M.

    1999-01-01

    The actuator disc model is applied on lattice-type meteorological masts to estimate the influence of the tower on the accuracy of the measured wind speed. Combining the results with corrections for the boom, on which the anemometer is mounted, good agreement is found for measurements made on the ...

  10. Observed rise of visible plumes from hyperbolic natural draft cooling towers

    Energy Technology Data Exchange (ETDEWEB)

    Brennan, P T [Smith-Singer Meteorologists, Inc., Amityville, NY; Seymour, D E; Butler, M J; Kramer, M L; Smith, M E; Frankenberg, T T

    1976-01-01

    The behavior of natural draft cooling tower plumes and related meteorological variables have been measured from aircraft near three major plants of the American Electric Power System. The rise of those plumes which persisted long enough to reach a stabilized height depended primarily upon the height of the capping inversion aloft. All such plumes rose to elevations of 425 m or more above grade. No significant relationships between plume rise and wind speed, plant load, or ambient temperature were found. We conclude that simple temperature humidity soundings in the vicinity of the towers would serve as effective predictors of plume rise and persistence.

  11. EDF's ageing management program for cooling towers

    International Nuclear Information System (INIS)

    Roure, T.; Crolet, Y.

    2015-01-01

    EDF operates a large fleet of cooling towers for its thermal and nuclear plants. Proactive maintenance strategies require ranking the towers according to the risk of failure and the observed damage. The ranking includes monitoring data such as: foundation settlements, material properties, quantified crack patterns, shell deformation, meteorological data, and corrosion. The numerical tool suite includes a finite element analysis of each tower under thermal and mechanical loadings and a corrosion predicting tool, based on carbonation. The first module computes the behavior of cooling towers under five types of loading: soil differential settlement, self-weight, moisture transport, temperature and wind. By comparison with the ultimate resisting capacity of the reinforced concrete cross section, a risk index map is produced for each tower. This risk index is used to rank the cooling towers and then to identify which structures should be monitored more closely or reinforced - if needed - first in the case of an extended operating life. The second module aims to anticipate the corrosion depth of reinforcement steel of the towers in the future. Examination of the existing carbonation is currently done for each structure and evolution of the carbonation depth is computed so as to predict with reasonable assurance when carbonation reaches the rebars. A prediction of the eventual cross-section loss of rebars is then made for long term analysis (i.e. up to 60 years of operating life). When corrosion is predicted the first module takes into account this loss and computes the behavior of the predicted corrosion damaged structure under the same loadings. (authors)

  12. Los Alamos National Laboratory Meteorology Monitoring Program: 2016 Data Completeness/ Quality Report

    Energy Technology Data Exchange (ETDEWEB)

    Bruggeman, David Alan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-06-15

    This report summarizes data completeness by tower and by instrument for 2016 and compares that data with the Los Alamos National Laboratory (LANL) and American National Standards Institute (ANSI) 2015 standards. This report is designed to make data users aware of data completeness and any data quality issues. LANL meteorology monitoring goals include 95% completeness for all measurements. The ANSI 2015 standard requires 90% completeness for all measurements. This report documents instrument/tower issues as they impact data completeness.

  13. Meteorological experiments for emergency preparedness. part 1

    International Nuclear Information System (INIS)

    Leao, I.L.B.; Nicolli, D.

    1993-12-01

    Since the preliminary studies for the Angra dos Reis Nuclear Power Plant (NPP) siting, by an American consultant company, it was verified that the micro scale and mesoscale meteorological conditions in the region show a unique complex pattern, so that no similar nuclear installation site could be found for reference. Therefore, it was recommended to install onsite a correspondingly complex meteorological data acquisition system which comprises a 100-meter tower with instruments at three different levels and three 15-meter satellite towers on the hills around. In this report, are described the equipment and instruments sent by the IAEA to CNEN as well as the procedures and particular computer programming developed by the staff. It is also reported on the bureaucratic problems and meager budget allocation for the Project which delayed the installation of the two meteorological stations and hindered the implementation of the Project. The equipment for the atmospheric boundary layer sounding were used for the first time in September 1993, when CNEN provided some resource for the purchase of gas and batteries. The first atmospheric sounding campaign showed the occurrence of strong night winds and intense thermal inversion at the higher level of the boundary layer, until now unknown by the Brazilian meteorologists. By way of this report, the staff of meteorologists tries to show the status of Project BRA/09/031 and the know-how gained with it. (author)

  14. Automated emergency meteorological response system

    International Nuclear Information System (INIS)

    Pepper, D.W.

    1980-01-01

    A sophisticated emergency response system was developed to aid in the evaluation of accidental releases of hazardous materials from the Savannah River Plant to the environment. A minicomputer system collects and archives data from both onsite meteorological towers and the National Weather Service. In the event of an accidental release, the computer rapidly calculates the trajectory and dispersion of pollutants in the atmosphere. Computer codes have been developed which provide a graphic display of predicted concentration profiles downwind from the source, as functions of time and distance

  15. Performance of water distribution systems in a pilot cooling tower

    International Nuclear Information System (INIS)

    Tognotti, L.; Giacomelli, A.; Zanelli, S.; Bellagamba, B.; Lotti, G.; Mattachini, F.

    1990-01-01

    An experimental study has been carried out on the water distribution system of a Pilot cooling tower of 160 m 3 /hr The performances of different industrial water distributors have been evaluated by changing the operative conditions of the pilot tower. In particular, the efficiency and the uniformity of the water distribution have been investigated and compared with the results obtained in a small-scale loop, in which the single nozzles were tested. Measurements in both systems, pilot tower and small scale loop, included the geometric characteristics of the jet umbrella by ensemble photography, the wetted zone by measuring the specific flowrate, the drop-size distribution and liquid concentration by high-speed photography. The results show that correlations exist between the nozzle behaviour in single and pilot tower configuration. The uniformity of water distribution in the pilot tower is strongly related to the nozzle installation pattern and to the operative conditions. Coalescence plays an important role on the drop size distribution in the pilot-tower. Comments upon the influence of these parameters on tower behaviour are also included

  16. Correlation between the meteorological data acquisition systems of the Centro Experimental ARAMAR

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Rando M.; Beu, Cássia M.L., E-mail: rando.oliveira@marinha.mil.br, E-mail: cassia.beu@marinha.mil.br [Centro Tecnológico da Marinha em São Paulo (CEA/CTMSP), Iperó, SP (Brazil). Centro Experimental ARAMAR

    2017-07-01

    Centro Experimental ARAMAR (CEA) is a Brazilian Navy Technological Center located in the rural area of lperó (São Paulo State), about 10-km distant from the nearest urban area. One of the most important activities at CEA is the nuclear fuel cycle research, as well as the development of a small-scale pressurized water reactor (PWR) land based prototype, The Laboratório Radioecológico (LAR E) is responsible for the meteorological observation program which relies on an automatic data collection system, The following variables are continuously measured: pressure, precipitation, wind speed, wind direction, temperature and relative humidity, The obtained data is refined and used in the annual reports to Comissão Nacional de Energia Nuclear (CNEN), and are an important input data for atmospheric dispersion models. Due to the construction of the Laboratório de Geraç!o Nucleoclétrica (LABGENE), it will be necessary to change tbe location of the towers and meteorological sensors, Thus, since 20 14, a new set of towers and sensors (Torre Nova) are in operation. The new location is 900 m distant from the old set (Torre Velha). Therefore, CEA has currently two meteorological data acquisition systems operating concurrently for approximately three years. The present work aims to compare the meteorological data of both systems in order to verify their agreement. The meteorological time series of both systems were submitted to a statistical analysis to evaluate their correlation. The results of this work confirm the compatibility of the two systems, showing that the Torre Velha can be deactivated without impairment to the meteorological time series. (author)

  17. Correlation between the meteorological data acquisition systems of the Centro Experimental ARAMAR

    International Nuclear Information System (INIS)

    Oliveira, Rando M.; Beu, Cássia M.L.

    2017-01-01

    Centro Experimental ARAMAR (CEA) is a Brazilian Navy Technological Center located in the rural area of lperó (São Paulo State), about 10-km distant from the nearest urban area. One of the most important activities at CEA is the nuclear fuel cycle research, as well as the development of a small-scale pressurized water reactor (PWR) land based prototype, The Laboratório Radioecológico (LAR E) is responsible for the meteorological observation program which relies on an automatic data collection system, The following variables are continuously measured: pressure, precipitation, wind speed, wind direction, temperature and relative humidity, The obtained data is refined and used in the annual reports to Comissão Nacional de Energia Nuclear (CNEN), and are an important input data for atmospheric dispersion models. Due to the construction of the Laboratório de Geraç!o Nucleoclétrica (LABGENE), it will be necessary to change tbe location of the towers and meteorological sensors, Thus, since 20 14, a new set of towers and sensors (Torre Nova) are in operation. The new location is 900 m distant from the old set (Torre Velha). Therefore, CEA has currently two meteorological data acquisition systems operating concurrently for approximately three years. The present work aims to compare the meteorological data of both systems in order to verify their agreement. The meteorological time series of both systems were submitted to a statistical analysis to evaluate their correlation. The results of this work confirm the compatibility of the two systems, showing that the Torre Velha can be deactivated without impairment to the meteorological time series. (author)

  18. The WACMOS-ET project – Part 1: Tower-scale evaluation of four remote sensing-based evapotranspiration algorithms

    KAUST Repository

    Michel, D.

    2015-10-20

    The WACMOS-ET project has compiled a forcing data set covering the period 2005–2007 that aims to maximize the exploitation of European Earth Observations data sets for evapotranspiration (ET) estimation. The data set was used to run 4 established ET algorithms: the Priestley–Taylor Jet Propulsion Laboratory model (PT-JPL), the Penman–Monteith algorithm from the MODIS evaporation product (PM-MOD), the Surface Energy Balance System (SEBS) and the Global Land Evaporation Amsterdam Model (GLEAM). In addition, in-situ meteorological data from 24 FLUXNET towers was used to force the models, with results from both forcing sets compared to tower-based flux observations. Model performance was assessed across several time scales using both sub-daily and daily forcings. The PT-JPL model and GLEAM provide the best performance for both satellite- and tower-based forcing as well as for the considered temporal resolutions. Simulations using the PM-MOD were mostly underestimated, while the SEBS performance was characterized by a systematic overestimation. In general, all four algorithms produce the best results in wet and moderately wet climate regimes. In dry regimes, the correlation and the absolute agreement to the reference tower ET observations were consistently lower. While ET derived with in situ forcing data agrees best with the tower measurements (R2 = 0.67), the agreement of the satellite-based ET estimates is only marginally lower (R2 = 0.58). Results also show similar model performance at daily and sub-daily (3-hourly) resolutions. Overall, our validation experiments against in situ measurements indicate that there is no single best-performing algorithm across all biome and forcing types. An extension of the evaluation to a larger selection of 85 towers (model inputs re-sampled to a common grid to facilitate global estimates) confirmed the original findings.

  19. A Method for Evaluation of Model-Generated Vertical Profiles of Meteorological Variables

    Science.gov (United States)

    2016-03-01

    evaluated WRF output for the boundary layer over Svalbard in the Arctic in terms of height above ground compared to tower and tethered balloon ...Valparaiso, Chile; 2011. Dutsch ML. Evaluation of the WRF model based on observations made by controlled meteorological balloons in the atmospheric

  20. Solar tower enhanced natural draft dry cooling tower

    Science.gov (United States)

    Yang, Huiqiang; Xu, Yan; Acosta-Iborra, Alberto; Santana, Domingo

    2017-06-01

    Concentrating Solar Power (CSP) plants are located in desert areas where the Direct Normal Irradiance (DNI) value is very high. Since water resource is scarcely available, mechanical draft cooing technology is commonly used, with power consumption of mechanical fans being approximately 2% of the total power generated. Today, there is only one solar power plant (Khi Solar One in South Africa) uses a condenser installed in a Natural Draft Cooling (NDC) tower that avoids the windage loss of water occurring in wet cooling towers. Although, Khi Solar One is a cavity receiver power tower, the receivers can be hung onto the NDC tower. This paper looks at a novel integration of a NDC tower into an external molten salt receiver of a solar power plant, which is one of a largest commercial molten salt tower in China, with 100MWe power capacity. In this configuration study, the NDC tower surrounds the concrete tower of the receiver concentrically. In this way, the receiver concrete tower is the central support of the NDC tower, which consists of cable networks that are fixed to the concrete tower and suspended at a certain height over the floor. The cable networks support the shell of the NDC tower. To perform a preliminary analysis of the behavior of this novel configuration, two cases of numerical simulation in three dimensional (3D) models have been solved using the commercial Computational Fluid Dynamics (CFD) code, ANSYS Fluent 6.3. The results show that the integration of the NDC tower into an external central receiver tower is feasible. Additionally, the total heat transfer rate is not reduced but slightly increases when the molten salt receiver is in operation because of the additional natural draft induced by the high temperature of the receiver.

  1. Probabilistic Capacity Assessment of Lattice Transmission Towers under Strong Wind

    Directory of Open Access Journals (Sweden)

    Wei eZhang

    2015-10-01

    Full Text Available Serving as one key component of the most important lifeline infrastructure system, transmission towers are vulnerable to multiple nature hazards including strong wind and could pose severe threats to the power system security with possible blackouts under extreme weather conditions, such as hurricanes, derechoes, or winter storms. For the security and resiliency of the power system, it is important to ensure the structural safety with enough capacity for all possible failure modes, such as structural stability. The study is to develop a probabilistic capacity assessment approach for transmission towers under strong wind loads. Due to the complicated structural details of lattice transmission towers, wind tunnel experiments are carried out to understand the complex interactions of wind and the lattice sections of transmission tower and drag coefficients and the dynamic amplification factor for different panels of the transmission tower are obtained. The wind profile is generated and the wind time histories are simulated as a summation of time-varying mean and fluctuating components. The capacity curve for the transmission towers is obtained from the incremental dynamic analysis (IDA method. To consider the stochastic nature of wind field, probabilistic capacity curves are generated by implementing IDA analysis for different wind yaw angles and different randomly generated wind speed time histories. After building the limit state functions based on the maximum allowable drift to height ratio, the probabilities of failure are obtained based on the meteorological data at a given site. As the transmission tower serves as the key nodes for the power network, the probabilistic capacity curves can be incorporated into the performance based design of the power transmission network.

  2. Environmental impact of cooling towers of large nuclear power plants

    International Nuclear Information System (INIS)

    Nester, K.

    1975-01-01

    The computer program for the calculation of the rise of cooling tower plumes (3-dimensional) was extented. In addition to the distributions of the vertical velocity, the temperatures and the specific humidity, it yields now the distribution of the rain droplets in the plume, too. The treatment of the cloud physics was based on the theory of Kessler (E. Kessler, Meteorological Monographs, 10 (1969) No. 32). (orig.) [de

  3. Meteorological effects of the mechanical-draft cooling towers of the Oak Ridge Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Hanna, S.R.

    1975-01-01

    The mechanical-draft cooling towers at the Oak Ridge Gaseous Diffusion Plant dissipate about 2000 MW of heat. Downwash occurs about 40 percent of the time, when wind speeds exceed about 3 m/sec. An elevated cloud forms about 10 percent of the time. The length of the visible plume, which is typically 100 or 200 m, is satisfactorily modeled if it is assumed that the plumes from all the cells in a cooling-tower bank combine. The calculation of fog concentration is complicated by the fact that the moisture is not inert but is taking part in the energy exchanges of a thermodynamic system. Calculations of drift deposition agree fairly well with observations

  4. A Meteorological Supersite for Aviation and Cold Weather Applications

    Science.gov (United States)

    Gultepe, Ismail; Agelin-Chaab, M.; Komar, J.; Elfstrom, G.; Boudala, F.; Zhou, B.

    2018-05-01

    The goal of this study is to better understand atmospheric boundary layer processes and parameters, and to evaluate physical processes for aviation applications using data from a supersite observing site. Various meteorological sensors, including a weather and environmental unmanned aerial vehicle (WE-UAV), and a fog and snow tower (FSOS) observations are part of the project. The PanAm University of Ontario Institute of Technology (UOIT) Meteorological Supersite (PUMS) observations are being collected from April 2015 to date. The FSOS tower gathers observations related to rain, snow, fog, and visibility, aerosols, solar radiation, and wind and turbulence, as well as surface and sky temperature. The FSOSs are located at three locations at about 450-800 m away from the PUMS supersite. The WE-UAV measurements representing aerosol, wind speed and direction, as well as temperature (T) and relative humidity (RH) are provided during clear weather conditions. Other measurements at the PUMS site include cloud backscattering profiles from CL51 ceilometer, MWR observations of liquid water content (LWC), T, and RH, and Microwave Rain Radar (MRR) reflectivity profile, as well as the present weather type, snow water depth, icing rate, 3D-ultrasonic wind and turbulence, and conventional meteorological observations from compact weather stations, e.g., WXTs. The results based on important weather event studies, representing fog, snow, rain, blowing snow, wind gust, planetary boundary layer (PBL) wind research for UAV, and icing conditions are given. The microphysical parameterizations and analysis processes for each event are provided, but the results should not be generalized for all weather events and be used cautiously. Results suggested that integrated observing systems based on data from a supersite as well as satellite sites can provide better information applicable to aviation meteorology, including PBL weather research, validation of numerical weather model predictions, and

  5. A Single Tower Configuration of the Modular Gamma Box Counter System - 13392

    Energy Technology Data Exchange (ETDEWEB)

    Morris, K.; Nakazawa, D.; Francalangia, J.; Gonzalez, H. [Canberra Industries Inc., 800 Research Parkway, Meriden, CT, 06450 (United States)

    2013-07-01

    Canberra's Standard Gamma Box Counter System is designed to perform accurate quantitative assays of gamma emitting nuclides for a wide range of large containers including B-25 crates and ISO shipping containers. Using a modular building-block approach, the system offers tremendous flexibility for a variety of measurement situations with wide ranges of sample activities and throughput requirements, as well as the opportunity to modify the configuration for other applications at a later date. The typical configuration consists of two opposing towers each equipped with two high purity germanium detectors, and an automated container trolley. This paper presents a modified configuration, consisting of a single tower placed inside a measurement trailer with three detector assemblies, allowing for additional vertical segmentation as well as a viewing a container outside the trailer through the trailer wall. An automatic liquid nitrogen fill system is supplied for each of the detectors. The use of a forklift to move the container for horizontal segmentation is accommodated by creating an additional operational and calibration set-up in the NDA 2000 software to allow for the operator to rotate the container and assay the opposite side, achieving the same sensitivity as a comparable two-tower system. This Segmented Gamma Box Counter System retains the core technologies and design features of the standard configuration. The detector assemblies are shielded to minimize interference from environmental and plant background, and are collimated to provide segmentation of the container. The assembly positions can also be modified in height and distance from the container. The ISOCS calibration software provides for a flexible approach to providing the calibrations for a variety of measurement geometries. The NDA 2000 software provides seamless operation with the current configuration, handling the data acquisition and analysis. In this paper, an overview of this system is

  6. Transporting method for adsorbing tower and the adsorbing tower

    International Nuclear Information System (INIS)

    Shimokawa, Nobuhiro.

    1996-01-01

    A cylindrical plastic bag is disposed to the upper surface of an adsorbing tower so as to surround a suspending piece. One opening of the bag is sealed, and other opening is secured in a sealed state to a bag holding portion disposed to glove box at a gate for the adsorbing tower box. The adsorbing tower is transported into the glove box, and after the completion of the operation of the adsorbing tower, the adsorbing tower is taken out in a state that the bag is restricted and sealed at a portion below the adsorbing tower. The bag may be made of a vinyl plastic, the bag holding portion may be a short-cylindrical protrusion, and may have an O-ring groove at the outer surface. Even if the adsorbing tower is heavy, the adsorbing tower can be carried out easily in a state where it is sealed gas tightly. (N.H.)

  7. Implementation of a micro-physical scheme for warm clouds in the meteorological model 'MERCURE': Application to cooling tower plumes and to orographic precipitation

    International Nuclear Information System (INIS)

    Bouzereau, Emmanuel

    2004-01-01

    A two-moment semi-spectral warm micro-physical scheme has been implemented inside the meteorological model 'MERCURE'. A new formulation of the buoyancy flux () is proposed, which is coherent with the corrigendum of Mellor (1977) but differs from Bougeault (1981). The non-precipitating cloud microphysics is validated by comparing the numerical simulations of fifteen cases of cooling tower plumes with data from a measurement campaign in Bugey in 1980. Satisfactory results are obtained on the plumes shape, on the temperature and vertical velocity fields and on the droplets spectrums, although the liquid water contents tend to be overestimated. The precipitating cloud microphysics is tested by reproducing the academical cases of orographic precipitation of Chaumerliac et al. (1987) and Richard and Chaumerliac (1989). The simulations allow a check of the action of different micro-physical terms. (author) [fr

  8. Noise from cooling towers of power parks

    International Nuclear Information System (INIS)

    Zakaria, J.; Moore, F.K.

    1975-01-01

    A study is presented of the noise pollution problem for large power parks proposed for the future. Such parks might have an area of about 75 sq. miles, and a generating capacity up to 48000 MW. A comparative analysis has been done for natural and mechanical-draft wet towers as the major sources of acoustic power. Noise radiation from single isolated towers as well as from a dispersed array of towers has been considered for both types of cooling systems. Major noise attenuation effects considered are due to the atmospheric absorption and A-weighting. Conditions of 60F and 70 percent relative humidity in a still atmosphere have been assumed

  9. Automated data system for emergency meteorological response

    International Nuclear Information System (INIS)

    Kern, C.D.

    1975-01-01

    The Savannah River Plant (SRP) releases small amounts of radioactive nuclides to the atmosphere as a consequence of the production of radioisotopes. The potential for larger accidental releases to the atmosphere also exists, although the probability for most accidents is low. To provide for emergency meteorological response to accidental releases and to conduct research on the transport and diffusion of radioactive nuclides in the routine releases, a series of high-quality meteorological sensors have been located on towers in and about SRP. These towers are equipped with instrumentation to detect and record temperature and wind turbulence. Signals from the meterological sensors are brought by land-line to the SRL Weather Center-Analysis Laboratory (WC-AL). At the WC-AL, a Weather Information and Display (WIND) system has been installed. The WIND system consists of a minicomputer with graphical displays in the WC-AL and also in the emergency operating center (EOC) of SRP. In addition, data are available to the system from standard weat []er teletype services, which provide both routine surface weather observations and routine upper air wind and temperature observations for the southeastern United States. Should there be an accidental release to the atmosphere, available recorded data and computer codes would allow the calculation and display of the location, time, and downwind concentration of the atmospheric release. These data are made available to decision makers in near real-time to permit rapid decisive action to limit the consequences of such accidental releases. (auth)

  10. Physical quantities related to measurement campaigns for cooling towers

    International Nuclear Information System (INIS)

    Boegel, W.

    1975-12-01

    The nomenclature in reports on the measurement campaigns for cooling towers will be adapted as far as possible to the already existing VDI report on this subject. On the other hand, the appropriate standards will also be accounted for. In order to facilitate a decision in individual cases in a first table the meteorologically or generally interesting quantities of the VDI reports are compared with the German, international, and WMO standards and - if necessary - also commented. A second table contains the air humidity parameters standardized by WMO including brief definitions. (orig/HP) [de

  11. The meteorological measurement system of the Karlsruhe Nuclear Research Center

    International Nuclear Information System (INIS)

    Dilger, H.

    1976-08-01

    The system mainly serves to record the parameters which are important for the diffusion of offgas plume. The system includes 47 instruments in total which are used to measure the wind velocity, the wind direction, the wind vector, the temperature, the dew point, the solar and heat radiation, the precipitations and the atmospheric pressure, most of them mounted at the 200 m high meteorological tower. (orig./HP) [de

  12. The WACMOS-ET project – Part 1: Tower-scale evaluation of four remote-sensing-based evapotranspiration algorithms

    KAUST Repository

    Michel, D.; Jimé nez, C.; Miralles, Diego G.; Jung, M.; Hirschi, M.; Ershadi, Ali; Martens, B.; McCabe, Matthew; Fisher, J. B.; Mu, Q.; Seneviratne, S. I.; Wood, E. F.; Ferná ndez-Prieto, D.

    2016-01-01

    The WAter Cycle Multi-mission Observation Strategy – EvapoTranspiration (WACMOS-ET) project has compiled a forcing data set covering the period 2005–2007 that aims to maximize the exploitation of European Earth Observations data sets for evapotranspiration (ET) estimation. The data set was used to run four established ET algorithms: the Priestley–Taylor Jet Propulsion Laboratory model (PT-JPL), the Penman–Monteith algorithm from the MODerate resolution Imaging Spectroradiometer (MODIS) evaporation product (PM-MOD), the Surface Energy Balance System (SEBS) and the Global Land Evaporation Amsterdam Model (GLEAM). In addition, in situ meteorological data from 24 FLUXNET towers were used to force the models, with results from both forcing sets compared to tower-based flux observations. Model performance was assessed on several timescales using both sub-daily and daily forcings. The PT-JPL model and GLEAM provide the best performance for both satellite- and tower-based forcing as well as for the considered temporal resolutions. Simulations using the PM-MOD were mostly underestimated, while the SEBS performance was characterized by a systematic overestimation. In general, all four algorithms produce the best results in wet and moderately wet climate regimes. In dry regimes, the correlation and the absolute agreement with the reference tower ET observations were consistently lower. While ET derived with in situ forcing data agrees best with the tower measurements (R2  =  0.67), the agreement of the satellite-based ET estimates is only marginally lower (R2  =  0.58). Results also show similar model performance at daily and sub-daily (3-hourly) resolutions. Overall, our validation experiments against in situ measurements indicate that there is no single best-performing algorithm across all biome and forcing types. An extension of the evaluation to a larger selection of 85 towers (model inputs resampled to a

  13. The WACMOS-ET project – Part 1: Tower-scale evaluation of four remote-sensing-based evapotranspiration algorithms

    KAUST Repository

    Michel, D.

    2016-02-23

    The WAter Cycle Multi-mission Observation Strategy – EvapoTranspiration (WACMOS-ET) project has compiled a forcing data set covering the period 2005–2007 that aims to maximize the exploitation of European Earth Observations data sets for evapotranspiration (ET) estimation. The data set was used to run four established ET algorithms: the Priestley–Taylor Jet Propulsion Laboratory model (PT-JPL), the Penman–Monteith algorithm from the MODerate resolution Imaging Spectroradiometer (MODIS) evaporation product (PM-MOD), the Surface Energy Balance System (SEBS) and the Global Land Evaporation Amsterdam Model (GLEAM). In addition, in situ meteorological data from 24 FLUXNET towers were used to force the models, with results from both forcing sets compared to tower-based flux observations. Model performance was assessed on several timescales using both sub-daily and daily forcings. The PT-JPL model and GLEAM provide the best performance for both satellite- and tower-based forcing as well as for the considered temporal resolutions. Simulations using the PM-MOD were mostly underestimated, while the SEBS performance was characterized by a systematic overestimation. In general, all four algorithms produce the best results in wet and moderately wet climate regimes. In dry regimes, the correlation and the absolute agreement with the reference tower ET observations were consistently lower. While ET derived with in situ forcing data agrees best with the tower measurements (R2  =  0.67), the agreement of the satellite-based ET estimates is only marginally lower (R2  =  0.58). Results also show similar model performance at daily and sub-daily (3-hourly) resolutions. Overall, our validation experiments against in situ measurements indicate that there is no single best-performing algorithm across all biome and forcing types. An extension of the evaluation to a larger selection of 85 towers (model inputs resampled to a

  14. Historical Single Image-Based Modeling: The Case of Gobierna Tower, Zamora (Spain

    Directory of Open Access Journals (Sweden)

    Jesús Garcia-Gago

    2014-01-01

    Full Text Available Historical perspective images have been proved to be very useful to properly provide a dimensional analysis of buildings façades or even to generate a pseudo-3D reconstruction based on rectified images of the whole structure. In this paper, the case of Gobierna Tower (Zamora, Spain is analyzed from a historical single image-based modeling approach. In particular, a bottom-up approach, which takes advantage from the perspective of the image, the existence of the three vanishing points and the usual geometric constraints (i.e., planarity, orthogonality, and parallelism is applied for the dimensional analysis of a destroyed historical building. Results were compared with ground truth measurements existing in a historical topographical surveying obtaining deviations of about 1%.

  15. A method to estimate the ageing of a cooling tower

    International Nuclear Information System (INIS)

    Barnel, Nathalie; Courtois, Alexis; Ilie, Petre-Lazar

    2006-09-01

    This paper deals with cooling towers ageing. Our contribution is a method to determine which part of on site measured strain we are able to predict by means of simulations. As a result, we map a gap indicator on the structure. Calculations have been performed in three configurations. Comparing the values obtained in the three cases helps to determine which researches are worth to be done. Indeed, gap indicator reveals that: - THM can not be considered as the main and only ageing mechanism, so long as tower older than 10 years are examined. At least creep has to be taken into account too; - Gap indicator is sensitive to initial hydration conditions. Drying process before bringing into service should be estimated properly, taking into account the different construction steps; - Comparing different thermal conditions reveals that meteorological conditions have a significant influence on results. So, it will be interesting to differentiate the sunny and the shaded part of the tower when the measurements are done; - A large part of the values obtained can be explicated by construction defects. A study on this particular problematic seems to be essential. The four items mentioned must be considered as perspectives to improve the present method of simulations. (authors)

  16. Evaluation of plume potential and plume abatement of evaporative cooling towers in a subtropical region

    International Nuclear Information System (INIS)

    Xu Xinhua; Wang Shengwei; Ma Zhenjun

    2008-01-01

    Hong Kong is a typical subtropical region with frequently high humidity in late spring and summer seasons. Plume from evaporative cooling towers, which service air-conditioning systems of civil buildings, has aroused public concerns since 2000 when the fresh water evaporative cooling towers were allowed to be used for high energy efficiency and environmental issues. This paper presents the evaluation of the plume potential and its effect on the sizing of the plume abatement system in a large commercial office building in Hong Kong for practical application. This evaluation was conducted based on a dynamic simulation platform using the typical meteorological year of Hong Kong since the occurrence of the plume heavily depends on the state conditions of the exhaust air from cooling towers and the ambient air, while the state condition of the exhaust air is determined by the total building cooling load and the control strategies of cooling towers employed mainly for improving energy efficiency. The results show that the control strategies have a significant effect on the plume potential and further affect the system design and sizing of the plume abatement system

  17. Overall analysis of meteorological information in the daeduk nuclear complex

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Byung Woo; Lee, Young Bok; Han, Moon Hee; Kim, Eun Han; Suh, Kyung Suk; Hwang, Won Tae; Hong, Suk Boong [Korea Atomic Energy Res. Inst., Taejon (Korea, Republic of)

    1992-12-01

    Problem shooting in tower structure, sensor installation, earth, and cabling have been done with integrated field-test, establishment of data acquisition system, and instrument calibration since the completion of the main tower construction in this year. Procedure guide was also made for the effective management covering instrument operation, calibration and repair. Real measurement has been done during two months from this October after whole integration of equipments. Occurrence of nocturnal inversion layer, fogging, and frequent stable condition of atmospheric stability were shown as the analysis results of measured data which well represented seasonal and regional characteristics in the site. Wireless data transmission to MIPS(Meteorological Information Processing System) has been done after collection in the DAS(data acquision system) where environmental assessment can be done by the developed simulation programs in both cases of normal operation and emergency. (Author).

  18. The experimental study of pollution meteorology and diffusion feature in the site of Tianwan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Hu Erbang; Yao Rentai; Xin Cuntian; Chen Jiayi

    2003-01-01

    The experimental observation and study of pollution meteorology and diffusion feature in site of Tianwan nuclear power plant is described. Four sets of (10, 30, 70, 100 m) sensors set on a 100-m-height tower to measure wind speed, wind direction and temperature were used to obtain hourly meteorological information during 1997-08 to 1999-08. The feature of middle scale wind field and the example and frequency of sea and land breezes are analyzed. The observation and formula of the internal boundary layer are completed. A simulation tests were done in a wind tunnel. In order to obtain the diffusion parameter the turbulence observation on two height of 100 m-height tower and 10 sets of SF 6 tracer experiments were done in summer, 1997. Based on above measured data the annual atmospheric dispersion factor and the accident probability dispersion factor at the boundary of an area of no residences were estimated. (authors)

  19. Cooling tower calculations

    International Nuclear Information System (INIS)

    Simonkova, J.

    1988-01-01

    The problems are summed up of the dynamic calculation of cooling towers with forced and natural air draft. The quantities and relations are given characterizing the simultaneous exchange of momentum, heat and mass in evaporative water cooling by atmospheric air in the packings of cooling towers. The method of solution is clarified in the calculation of evaporation criteria and thermal characteristics of countercurrent and cross current cooling systems. The procedure is demonstrated of the calculation of cooling towers, and correction curves and the effect assessed of the operating mode at constant air number or constant outlet air volume flow on their course in ventilator cooling towers. In cooling towers with the natural air draft the flow unevenness is assessed of water and air relative to its effect on the resulting cooling efficiency of the towers. The calculation is demonstrated of thermal and resistance response curves and cooling curves of hydraulically unevenly loaded towers owing to the water flow rate parameter graded radially by 20% along the cross-section of the packing. Flow rate unevenness of air due to wind impact on the outlet air flow from the tower significantly affects the temperatures of cooled water in natural air draft cooling towers of a design with lower demands on aerodynamics, as early as at wind velocity of 2 m.s -1 as was demonstrated on a concrete example. (author). 11 figs., 10 refs

  20. Simultaneous multicopter-based air sampling and sensing of meteorological variables

    Science.gov (United States)

    Brosy, Caroline; Krampf, Karina; Zeeman, Matthias; Wolf, Benjamin; Junkermann, Wolfgang; Schäfer, Klaus; Emeis, Stefan; Kunstmann, Harald

    2017-08-01

    The state and composition of the lowest part of the planetary boundary layer (PBL), i.e., the atmospheric surface layer (SL), reflects the interactions of external forcing, land surface, vegetation, human influence and the atmosphere. Vertical profiles of atmospheric variables in the SL at high spatial (meters) and temporal (1 Hz and better) resolution increase our understanding of these interactions but are still challenging to measure appropriately. Traditional ground-based observations include towers that often cover only a few measurement heights at a fixed location. At the same time, most remote sensing techniques and aircraft measurements have limitations to achieve sufficient detail close to the ground (up to 50 m). Vertical and horizontal transects of the PBL can be complemented by unmanned aerial vehicles (UAV). Our aim in this case study is to assess the use of a multicopter-type UAV for the spatial sampling of air and simultaneously the sensing of meteorological variables for the study of the surface exchange processes. To this end, a UAV was equipped with onboard air temperature and humidity sensors, while wind conditions were determined from the UAV's flight control sensors. Further, the UAV was used to systematically change the location of a sample inlet connected to a sample tube, allowing the observation of methane abundance using a ground-based analyzer. Vertical methane gradients of about 0.3 ppm were found during stable atmospheric conditions. Our results showed that both methane and meteorological conditions were in agreement with other observations at the site during the ScaleX-2015 campaign. The multicopter-type UAV was capable of simultaneous in situ sensing of meteorological state variables and sampling of air up to 50 m above the surface, which extended the vertical profile height of existing tower-based infrastructure by a factor of 5.

  1. A Meteorological Distribution System for High Resolution Terrestrial Modeling (MicroMet)

    Science.gov (United States)

    Liston, G. E.; Elder, K.

    2004-12-01

    Spatially distributed terrestrial models generally require atmospheric forcing data on horizontal grids that are of higher resolution than available meteorological data. Furthermore, the meteorological data collected may not necessarily represent the area of interest's meteorological variability. To address these deficiencies, computationally efficient and physically realistic methods must be developed to take available meteorological data sets (e.g., meteorological tower observations) and generate high-resolution atmospheric-forcing distributions. This poster describes MicroMet, a quasi-physically-based, but simple meteorological distribution model designed to produce high-resolution (e.g., 5-m to 1-km horizontal grid increments) meteorological data distributions required to run spatially distributed terrestrial models over a wide variety of landscapes. The model produces distributions of the seven fundamental atmospheric forcing variables required to run most terrestrial models: air temperature, relative humidity, wind speed, wind direction, incoming solar radiation, incoming longwave radiation, and precipitation. MicroMet includes a preprocessor that analyzes meteorological station data and identifies and repairs potential data deficiencies. The model uses known relationships between meteorological variables and the surrounding area (primarily topography) to distribute those variables over any given landscape. MicroMet performs two kinds of adjustments to available meteorological data: 1) when there are data at more than one location, at a given time, the data are spatially interpolated over the domain using a Barnes objective analysis scheme, and 2) physical sub-models are applied to each MicroMet variable to improve its realism at a given point in space and time with respect to the terrain. The three, 25-km by 25-km, Cold Land Processes Experiment (CLPX) mesoscale study areas (MSAs: Fraser, North Park, and Rabbit Ears) will be used as example Micro

  2. Evaluation of Savannah River Plant emergency response models using standard and nonstandard meteorological data

    International Nuclear Information System (INIS)

    Hoel, D.D.

    1984-01-01

    Two computer codes have been developed for operational use in performing real time evaluations of atmospheric releases from the Savannah River Plant (SRP) in South Carolina. These codes, based on mathematical models, are part of the SRP WIND (Weather Information and Display) automated emergency response system. Accuracy of ground level concentrations from a Gaussian puff-plume model and a two-dimensional sequential puff model are being evaluated with data from a series of short range diffusion experiments using sulfur hexafluoride as a tracer. The models use meteorological data collected from 7 towers on SRP and at the 300 m WJBF-TV tower about 15 km northwest of SRP. The winds and the stability, which is based on turbulence measurements, are measured at the 60 m stack heights. These results are compared to downwind concentrations using only standard meteorological data, i.e., adjusted 10 m winds and stability determined by the Pasquill-Turner stability classification method. Scattergrams and simple statistics were used for model evaluations. Results indicate predictions within accepted limits for the puff-plume code and a bias in the sequential puff model predictions using the meteorologist-adjusted nonstandard data. 5 references, 4 figures, 2 tables

  3. Vertical Deformation Monitoring of the Suspension Bridge Tower Using GNSS: A Case Study of the Forth Road Bridge in the UK

    Directory of Open Access Journals (Sweden)

    Qusen Chen

    2018-02-01

    Full Text Available The vertical deformation monitoring of a suspension bridge tower is of paramount importance to maintain the operational safety since nearly all forces are eventually transferred as the vertical stress on the tower. This paper analyses the components affecting the vertical deformation and attempts to reveal its deformation mechanism. Firstly, we designed a strategy for high-precision GNSS data processing aiming at facilitating deformation extraction and analysis. Then, 33 months of vertical deformation time series of the southern tower of the Forth Road Bridge (FRB in the UK were processed, and the accurate subsidence and the parameters of seasonal signals were estimated based on a classic function model that has been widely studied to analyse GNSS coordinate time series. We found that the subsidence rate is about 4.7 mm/year, with 0.1 mm uncertainty. Meanwhile, a 15-month meteorological dataset was utilised with a thermal expansion model (TEM to explain the effects of seasonal signals on tower deformation. The amplitude of the annual signals correlated quite well that obtained by the TEM, with the consistency reaching 98.9%, demonstrating that the thermal effect contributes significantly to the annual signals. The amplitude of daily signals displays poor consistency with the ambient temperature data. However, the phase variation tendencies between the daily signals of the vertical deformation and the ambient temperature are highly consistent after February 2016. Finally, the potential contribution of the North Atlantic Drift (NAD to the characteristics of annual and daily signals is discussed because of the special geographical location of the FRB. Meanwhile, this paper emphasizes the importance of collecting more detailed meteorological and other loading data for the investigation of the vertical deformation mechanism of the bridge towers over time with the support of GNSS.

  4. Wind-induced response analysis of a wind turbine tower including the blade-tower coupling effect

    Institute of Scientific and Technical Information of China (English)

    Xiao-bo CHEN; Jing LI; Jian-yun CHEN

    2009-01-01

    To analyze wind-induced response characteristics of a wind turbine tower more accurately, the blade-tower coupling effect was investigated. The mean wind velocity of the rotating blades and tower was simulated according to wind shear effects,and the fluctuating wind velocity time series of the wind turbine were simulated by a harmony superposition method. A dynamic finite element method (FEM) was used to calculate the wind-induced response of the blades and tower. Wind-induced responses of the tower were calculated in two cases (one included the blade-tower coupling effect, and the other only added the mass of blades and the hub at the top of the tower), and then the maximal displacements at the top of the tower of the tow cases were compared with each other. As a result of the influence of the blade-tower coupling effect and the total base shear of the blades, the maximal displacement of the first case increased nearly by 300% compared to the second case. To obtain more precise analysis, the blade-tower coupling effect and the total base shear of the blades should be considered simultaneously in the design of wind turbine towers.

  5. Tower counts

    Science.gov (United States)

    Woody, Carol Ann; Johnson, D.H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Counting towers provide an accurate, low-cost, low-maintenance, low-technology, and easily mobilized escapement estimation program compared to other methods (e.g., weirs, hydroacoustics, mark-recapture, and aerial surveys) (Thompson 1962; Siebel 1967; Cousens et al. 1982; Symons and Waldichuk 1984; Anderson 2000; Alaska Department of Fish and Game 2003). Counting tower data has been found to be consistent with that of digital video counts (Edwards 2005). Counting towers do not interfere with natural fish migration patterns, nor are fish handled or stressed; however, their use is generally limited to clear rivers that meet specific site selection criteria. The data provided by counting tower sampling allow fishery managers to determine reproductive population size, estimate total return (escapement + catch) and its uncertainty, evaluate population productivity and trends, set harvest rates, determine spawning escapement goals, and forecast future returns (Alaska Department of Fish and Game 1974-2000 and 1975-2004). The number of spawning fish is determined by subtracting subsistence, sport-caught fish, and prespawn mortality from the total estimated escapement. The methods outlined in this protocol for tower counts can be used to provide reasonable estimates ( plus or minus 6%-10%) of reproductive salmon population size and run timing in clear rivers. 

  6. Method to characterize local meteorology at nuclear facilities for application to emergency response needs

    International Nuclear Information System (INIS)

    Lindsey, C.G.; Glantz, C.S.

    1986-04-01

    Effluent dispersion is evaluated using computer codes that require various meteorological parameters such as wind and stability data. These data will be based on current conditions at the site in question, and on forecasts of the expected local meteorology for the time period to be simulated. To assist NRC personnel in preparing these forecasts, a weather-typing model was implemented to analyze the characteristic behavior of local meteorology as it responds to various synoptic-scale weather features (e.g., warm fronts, cold fronts, high pressure systems). Historical observations acquired by instrumented towers at several nuclear power plants were analyzed as a function of the prevailing synoptic weather feature, synoptic-scale pressure gradient, and time of year. This study focused on sites located in shoreline and complex terrain environments because of the occurrence of mesoscale circulations, which are the sea/lake-land breeze and valley wind systems. Such circulations produce diurnally changing wind and stability conditions that cannot be readily identified by synoptic-scale weather forecasts. The advantage in analyzing the climatological behavior of local meteorology as it responds to various synoptic weather systems is that certain weather systems will control the local meteorology and produce persistent conditions

  7. Water tower

    CERN Multimedia

    CERN PhotoLab

    1970-01-01

    The water tower, being built on the highest point of the site, 460.5 m above the sea level. The tank will hold 750 m3 of water, and the tower will be topped by a knob which can serve as a geological survey reference mark.

  8. Assessing the environmental health relevance of cooling towers--a systematic review of legionellosis outbreaks.

    Science.gov (United States)

    Walser, Sandra M; Gerstner, Doris G; Brenner, Bernhard; Höller, Christiane; Liebl, Bernhard; Herr, Caroline E W

    2014-03-01

    Bioaerosols from cooling towers are often suspected to cause community-acquired legionellosis outbreaks. Although Legionella infections can mostly be assigned to the emission sources, uncertainty exists about the release and distribution into the air, the occurrence of the respirable virulent form and the level of the infective concentration. Our study aimed to evaluate studies on legionellosis outbreaks attributed to cooling towers published within the last 11 years by means of a systematic review of the literature. 19 legionellosis outbreaks were identified affecting 12 countries. Recurring events were observed in Spain and Great Britain. In total, 1609 confirmed cases of legionellosis and a case-fatality rate of approximately 6% were reported. Duration of outbreaks was 65 days on average. For diagnosis the urinary antigen test was mainly used. Age, smoking, male sex and underlying diseases (diabetes, immunodeficiency) could be confirmed as risk factors. Smoking and underlying diseases were the most frequent risk factors associated with legionellosis in 11 and 10 of the 19 studies, respectively. The meteorological conditions varied strongly. Several studies reported a temporal association of outbreaks with inadequate maintenance of the cooling systems. A match of clinical and environmental isolates by serotyping and/or molecular subtyping could be confirmed in 84% of outbreaks. Legionella-contaminated cooling towers as environmental trigger, in particular in the neighbourhood of susceptible individuals, can cause severe health problems and even death. To prevent and control Legionella contamination of cooling towers, maintenance actions should focus on low-emission cleaning procedures of cooling towers combined with control measurements of water and air samples. Procedures allowing rapid detection and risk assessment in the case of outbreaks are essential for adequate public health measures. Systematic registration of cooling towers will facilitate the

  9. Formation of secondary inorganic aerosols by power plant emissions exhausted through cooling towers in Saxony.

    Science.gov (United States)

    Hinneburg, Detlef; Renner, Eberhard; Wolke, Ralf

    2009-01-01

    The fraction of ambient PM10 that is due to the formation of secondary inorganic particulate sulfate and nitrate from the emissions of two large, brown-coal-fired power stations in Saxony (East Germany) is examined. The power stations are equipped with natural-draft cooling towers. The flue gases are directly piped into the cooling towers, thereby receiving an additionally intensified uplift. The exhausted gas-steam mixture contains the gases CO, CO2, NO, NO2, and SO2, the directly emitted primary particles, and additionally, an excess of 'free' sulfate ions in water solution, which, after the desulfurization steps, remain non-neutralized by cations. The precursor gases NO2 and SO2 are capable of forming nitric and sulfuric acid by several pathways. The acids can be neutralized by ammonia and generate secondary particulate matter by heterogeneous condensation on preexisting particles. The simulations are performed by a nested and multi-scale application of the online-coupled model system LM-MUSCAT. The Local Model (LM; recently renamed as COSMO) of the German Weather Service performs the meteorological processes, while the Multi-scale Atmospheric Transport Model (MUSCAT) includes the transport, the gas phase chemistry, as well as the aerosol chemistry (thermodynamic ammonium-sulfate-nitrate-water system). The highest horizontal resolution in the inner region of Saxony is 0.7 km. One summer and one winter episode, each realizing 5 weeks of the year 2002, are simulated twice, with the cooling tower emissions switched on and off, respectively. This procedure serves to identify the direct and indirect influences of the single plumes on the formation and distribution of the secondary inorganic aerosols. Surface traces of the individual tower plumes can be located and distinguished, especially in the well-mixed boundary layer in daytime. At night, the plumes are decoupled from the surface. In no case does the resulting contribution of the cooling tower emissions to PM10

  10. The quantity of algae colonizing the inside face of cooling towers and the consequences for wear of the shell

    International Nuclear Information System (INIS)

    Aprosi, G.; Chauvel, D.

    1990-01-01

    These studies are part of the interdirectorate working group's mandate relating to lifespan project on cooling towers. Involving the collaboration of several divisions of Electricity de France: the Construction Division (SEPTEN). The Generation and Transmission Division (SPT) and the Research and Development Division (EAA). Among the biological colonies which proliferate in the cooling circuits of power stations, algae are broadly represented in the form of wall coatings which cover the inside face of cooling towers: shell algae. They can also grow at other points in the cooling circuit; in the cold water basin, in the fill, and, in some cooling towers, in the hot water basin. These plant organisms hamper the operation of power stations by clogging the grids located in the pipe from the cold water basin to the condenser. In addition, when algae come free of the shell, they remove micro-fragments of the concrete, which could accelerate wear. This paper presents the findings of studies conducted by the Aquatic and Atmospheric Department on the infestation of cooling towers by algae. In particular, the results of studies to evaluate the quantity of algae on the inside face of the shell of cooling towers. Many scenarios will be proposed, linked to the operation of the plant and to the local meteorological conditions

  11. Tower Based Load Measurements for Individual Pitch Control and Tower Damping of Wind Turbines

    International Nuclear Information System (INIS)

    Kumar, A A; Hugues-Salas, O; Savini, B; Keogh, W

    2016-01-01

    The cost of IPC has hindered adoption outside of Europe despite significant loading advantages for large wind turbines. In this work we presented a method for applying individual pitch control (including for higher-harmonics) using tower-top strain gauge feedback instead of blade-root strain gauge feedback. Tower-top strain gauges offer hardware savings of approximately 50% in addition to the possibility of easier access for maintenance and installation and requiring a less specialised skill-set than that required for applying strain gauges to composite blade roots. A further advantage is the possibility of using the same tower-top sensor array for tower damping control. This method is made possible by including a second order IPC loop in addition to the tower damping loop to reduce the typically dominating 3P content in tower-top load measurements. High-fidelity Bladed simulations show that the resulting turbine spectral characteristics from tower-top feedback IPC and from the combination of tower-top IPC and damping loops largely match those of blade-root feedback IPC and nacelle- velocity feedback damping. Lifetime weighted fatigue analysis shows that the methods allows load reductions within 2.5% of traditional methods. (paper)

  12. A modular restoration tower for electric power line transmission

    Energy Technology Data Exchange (ETDEWEB)

    Nicolazzi, L.C.; Pereira, J.C.; Leonel, C.E.L.; Rocha, G.B.; Bianchezzi, V.; Mendes, F. [Universidade Federal Santa Catarina (UFSC), Florianopolis, SC (Brazil). Dept. de Engenharia Mecanica], Emails: lauro@grante.ufsc.br, jcarlos@grante.ufsc.br; Luz, R.L. [ELETROSUL Centrais Eletricas S.A., Florianopolis, SC (Brazil)], Email: rluz@eletrosul.gov.br

    2009-07-01

    The main target of this R and D project is to develop an restoration tower for electric energy lines transmission. Whereas these towers should present the main features like transport facility, easiest assembling associated with a low cost of manufacture, it was applied the single-column tower concepts supported by stays, modularized, framed and articulated at the base. The concepts used for this development was a design methodology. From the different definition situations of load, numerical models have been developed focusing the design to the best of structural element arrangements of its modules. Then, tests were performed in laboratory to determine the module structural performance for different work load situations. These tests served to identify inconsistencies in the numerical models and proposed adjustments in its design to improve its performance on the strength and stability. (author)

  13. Origin and prevention of infection with Legionella pneumophila through cooling towers and evaporative cooling towers

    International Nuclear Information System (INIS)

    Schulze-Roebbecke, R.

    1994-01-01

    Evaporative cooling towers and industrial ventilator cooling towers have repeatedly been described as the origin of Legionnaires' disease. This article describes the design and function of cooling towers and evaporative cooling towers, sums up knowledge on the colonization of such systems with Legionella pneumophila, and describes conditions permitting the transmission of Legionella. Furthermore, design, maintenance, cleaning and disinfection measures are indicated which are believed to reduce the risk of infection through industrial and evaporative cooling towers. (orig.) [de

  14. New student-designed research and demonstration drop tower

    Science.gov (United States)

    Bell, Donald; Weislogel, Mark

    A new drop tower has been designed and constructed at Portland State University. The ap-proach incorporates innovative features to increase throughput and microgravity quality in a highly public facility. Push button operation with full wireless CCTV coverage and passive magnetic deceleration provides quiet, safe operation from a single control station with low re-cycle time. A two-stage coaxial release mechanism decouples the payload from the drag shield to minimize disturbances to the experiment during release. This is especially important for fluids experiments that are highly sensitive to initial conditions. Performance of the new tower is presented including release, free fall, and deceleration accelerometer data. The two second tower is used for research and educational outreach. The research efforts focus on capillary flows and phenomena relevant to spacecraft fluid systems. The outreach efforts utilize partnerships with local primary, secondary and post-secondary institutions to promote the fields of science, technology, engineering and mathematics.

  15. Easy steel tower elevation. Development of a steel tower elevating aiding device; Tetto shoko wo rakuraku to. Tetto shoko hojo sochi no kaihatsu ni tsuite

    Energy Technology Data Exchange (ETDEWEB)

    Tobe, Y. [Kansai Electric Power Co. Inc., Osaka (Japan)

    1999-02-10

    Elevation of a transmission line steel tower is performed by an operator`s own force upon fixing a safety device to prevent a fall on a safety wire (SW) previously installed on a specified tower leg. It is a considerable burden for the operator to move the tower having a height of 80 to 100 m up and down several times a day. In order to reduce the fatigue, a portable, small and light-weight steel tower elevation aiding device was developed. The existing SW is used to fix the device, requiring no additional facility to be fixed on the tower. Safety assurance depends on the safety device on the SW as currently used. The device has pulling force of 50 kgf (the device operates in a range of 4 to 50 kgf to assure workability in elevation and stopping), and elevation speed of 15 to 20 m/minute (equivalent to the present work. The braking force can be adjusted in three steps at descent according to the ability of the operator). An Ni-hydrogen battery is used, capable of two returns on a tower per charge. Considering the device to be transported in mountainous area, the shape is such that a single unit can be put into a backpack. The device can also be used in general construction sites. (NEDO)

  16. Composite wind turbine towers

    Energy Technology Data Exchange (ETDEWEB)

    Polyzois, D. [Manitoba Univ., Winnipeg, MB (Canada). Dept. of Civil Engineering

    2008-07-01

    This paper discussed experiments conducted to optimized the advanced composite materials such as fiberglass reinforced plastics (FRP) used to fabricate wind turbine towers. FRP materials are used in tubular steel, lattice, guyed, and reinforced concrete towers. The towers and turbine blades are transported in segments and assembled on-site, sometimes in offshore or remote locations.The FRP composites are used to build towers with a high strength-to-weight ratio as well as to provide resistance to chemical attacks and corrosion. Use of the materials has resulted in towers that do not require heavy installation equipment. Experimental programs were conducted to verify the structural behaviour of the tower structure's individual-scaled cells as well as to evaluate the performance of multi-cell assemblies. Joint assembly designs were optimized, and a filament winding machine was used to conduct the experimental study and to test individual cells. Failure mode analyses were conducted to determine local buckling and shear rupture. Tension, compression, and shear properties of the FRP materials were tested experimentally, and data from the test were then used to develop finite element models of the composite towers as well as to obtain load deflection curves and tip oscillation data. A case study of a 750 kW wind turbine in Churchill, Manitoba was used to test the design. tabs., figs.

  17. Improve crossflow cooling tower operation

    International Nuclear Information System (INIS)

    Burger, R.

    1989-01-01

    This paper reports how various crossflow cooling tower elements can be upgraded. A typical retrofit example is presented. In the past decade, cooling tower technology has progressed. If a cooling tower is over ten years old, chances are the heat transfer media and mechanical equipment were designed over 30 to 40 years ago. When a chemical plant expansion is projected or a facility desires to upgrade its equipment for greater output and energy efficiency, the cooling tower is usually neglected until someone discovers that the limiting factor of production is the quality of cold water returning from the cooling tower

  18. Good Towers of Function Fields

    DEFF Research Database (Denmark)

    Bassa, Alp; Beelen, Peter; Nguyen, Nhut

    2014-01-01

    In this paper, we will give an overview of known and new techniques on how one can obtain explicit equations for candidates of good towers of function fields. The techniques are founded in modular theory (both the classical modular theory and the Drinfeld modular theory). In the classical modular...... setup, optimal towers can be obtained, while in the Drinfeld modular setup, good towers over any non-prime field may be found. We illustrate the theory with several examples, thus explaining some known towers as well as giving new examples of good explicitly defined towers of function fields....

  19. Mathematical model of drift deposition from a bifurcated cooling tower plume

    International Nuclear Information System (INIS)

    Chen, N.C.J.; Jung, L.

    1978-01-01

    Cooling tower drift deposition modeling has been extended by including centrifugal force induced through plume bifurcation in a crosswind as a mechanism for drift droplet removal from the plume. The model, in its current state of development, is capable of predicting the trajectory of a single droplet from the stage of strong interaction with the vortex field soon after droplet emission at the tower top through the stage of droplet evaporation in an unsaturated atmosphere after droplet breakaway from the plume. The computer program developed from the mathematical formulation has been used to explore the dependency of the droplet trajectory on droplet size, vortex strength, point of droplet emission, drag coefficient, droplet efflux speed, and ambient conditions. A specific application to drift from a mechanical-draft cooling tower (for a wind speed twice the efflux speed, a relative humidity of 70 per cent, and an initial droplet radius of 100 μm) showed the droplet to follow a helical trajectory within the plume, with breakaway occurring at 2.5 tower diameters downwind and ground impact of the droplet (reduced through evaporation to 55 μm radius) at 11 tower diameters

  20. Fire analog: a comparison between fire plumes and energy center cooling tower plumes

    Energy Technology Data Exchange (ETDEWEB)

    Orgill, M.M.

    1977-10-01

    Thermal plumes or convection columns associated with large fires are compared to thermal plumes from cooling towers and proposed energy centers to evaluate the fire analog concept. Energy release rates of mass fires are generally larger than for single or small groups of cooling towers but are comparable to proposed large energy centers. However, significant physical differences exist between cooling tower plumes and fire plumes. Cooling tower plumes are generally dominated by ambient wind, stability and turbulence conditions. Fire plumes, depending on burning rates and other factors, can transform into convective columns which may cause the fire behavior to become more violent. This transformation can cause strong inflow winds and updrafts, turbulence and concentrated vortices. Intense convective columns may interact with ambient winds to create significant downwind effects such as wakes and Karman vortex streets. These characteristics have not been observed with cooling tower plumes to date. The differences in physical characteristics between cooling tower and fire plumes makes the fire analog concept very questionable even though the approximate energy requirements appear to be satisfied in case of large energy centers. Additional research is suggested in studying the upper-level plume characteristics of small experimental fires so this information can be correlated with similar data from cooling towers. Numerical simulation of fires and proposed multiple cooling tower systems could also provide comparative data.

  1. Wind tower service lift

    Science.gov (United States)

    Oliphant, David; Quilter, Jared; Andersen, Todd; Conroy, Thomas

    2011-09-13

    An apparatus used for maintaining a wind tower structure wherein the wind tower structure may have a plurality of legs and may be configured to support a wind turbine above the ground in a better position to interface with winds. The lift structure may be configured for carrying objects and have a guide system and drive system for mechanically communicating with a primary cable, rail or other first elongate member attached to the wind tower structure. The drive system and guide system may transmit forces that move the lift relative to the cable and thereby relative to the wind tower structure. A control interface may be included for controlling the amount and direction of the power into the guide system and drive system thereby causing the guide system and drive system to move the lift relative to said first elongate member such that said lift moves relative to said wind tower structure.

  2. Experimental Investigation on Strengthening of Bolted Connections in Transmission/Communication Towers

    Science.gov (United States)

    Balagopal, R.; Prasad Rao, N.; Rokade, R. P.; Umesha, P. K.

    2018-02-01

    Due to increase in demand for power supply and increase in bandwidth for communication industry, the existing transmission line (TL) and communication towers needs to be strengthened. The strengthening of existing tower is economical rather than installation of new towers due to constraints in acquisition of land. The size of conductors have to be increased or additional number of antenna needs to be installed in existing TL/communication tower respectively. The compression and tension capacity of members in the existing towers have to be increased to sustain the additional loads due to wind and self-weight of these components. The tension capacity enhancement of existing angle sections in live line condition without power shut-down is a challenging task. In the present study, the use of Glass Fiber Reinforced Plastic (GFRP) plate/angle sections is explored to strengthen existing bolted connections in TL/communication towers. Experimental investigation conducted at component level on strengthening of existing two types of single cover steel butt joint, one made of steel plate and another joint made of steel angle sections respectively. First series of experiment conducted on strengthening the connection using GFRP plate/cleat angle sections. The second series of strengthening experiment is conducted using steel plate/angle sections to replace GFRP sections. The load sharing behaviour of strengthened GFRP and steel section is compared and suitable recommendations are given.

  3. Experimental Investigation on Strengthening of Bolted Connections in Transmission/Communication Towers

    Science.gov (United States)

    Balagopal, R.; Prasad Rao, N.; Rokade, R. P.; Umesha, P. K.

    2018-06-01

    Due to increase in demand for power supply and increase in bandwidth for communication industry, the existing transmission line (TL) and communication towers needs to be strengthened. The strengthening of existing tower is economical rather than installation of new towers due to constraints in acquisition of land. The size of conductors have to be increased or additional number of antenna needs to be installed in existing TL/communication tower respectively. The compression and tension capacity of members in the existing towers have to be increased to sustain the additional loads due to wind and self-weight of these components. The tension capacity enhancement of existing angle sections in live line condition without power shut-down is a challenging task. In the present study, the use of Glass Fiber Reinforced Plastic (GFRP) plate/angle sections is explored to strengthen existing bolted connections in TL/communication towers. Experimental investigation conducted at component level on strengthening of existing two types of single cover steel butt joint, one made of steel plate and another joint made of steel angle sections respectively. First series of experiment conducted on strengthening the connection using GFRP plate/cleat angle sections. The second series of strengthening experiment is conducted using steel plate/angle sections to replace GFRP sections. The load sharing behaviour of strengthened GFRP and steel section is compared and suitable recommendations are given.

  4. You're a What?: Tower Technician

    Science.gov (United States)

    Vilorio, Dennis

    2012-01-01

    In this article, the author talks about the role and functions of a tower technician. A tower technician climbs up the face of telecommunications towers to remove, install, test, maintain, and repair a variety of equipment--from antennas to light bulbs. Tower technicians also build shelters and radiofrequency shields for electronic equipment, lay…

  5. Cooling Tower Losses in Industry

    OpenAIRE

    Barhm Mohamad

    2017-01-01

    Cooling towers are a very important part of many chemical plants. The primary task of a cooling tower is to reject heat into the atmosphere. They represent a relatively inexpensive and dependable means of removing low-grade heat from cooling water. The make-up water source is used to replenish water lost to evaporation. Hot water from heat exchangers is sent to the cooling tower. The water exits the cooling tower and is sent back to the exchangers or to other units for further cooling.

  6. A community outbreak of Legionnaires' disease associated with a cooling tower in Vic and Gurb, Catalonia (Spain) in 2005.

    Science.gov (United States)

    Ferré, M R Sala; Arias, C; Oliva, J M; Pedrol, A; García, M; Pellicer, T; Roura, P; Domínguez, A

    2009-02-01

    We report the investigation of a community-acquired outbreak of Legionnaires' disease. An epidemiological, environmental, and meteorological investigation was undertaken. Fifty-five cases were reported in October and November 2005. The exposure occurred in a large area, with 12 cases (21.8%) located between 1,800 and 3,400 metres from the source. Water sample cultures showed that Legionella pneumophila serogroup 1 (Lp-1) was present in five cooling towers in two industrial locations in Gurb (plants A and B). Two Lp-1 strains were recovered from plants A and B, but only Lp-1 strains from plant A showed a pulsed-field gel electrophoresis (PFGE) profile identical to those obtained from three of the cases. Inspection of the cooling towers in plant A revealed inadequate maintenance. Weather conditions in October 2005, with mostly high temperatures and high humidity, together with the flat terrain could have been favouring factors. This study showed a community outbreak from a cooling tower as a common source in a large area. Climate and terrain could explain the dissemination of contaminated aerosols.

  7. Meteorological Effects of Thermal Energy Releases (METER) Program. Annual progress report, October 1978-September 1979

    International Nuclear Information System (INIS)

    Patrinos, A.A.N.; Hoffman, H.W.

    1980-04-01

    The METER (Meteorological Effects of Thermal Energy Releases) Program was organized to develop and verify methods for predicting the maximum amount of energy that can be dissipated to the atmosphere (through cooling towers or cooling ponds) from proposed nuclear energy centers without affecting...the local and regional environment. The initial program scope (mathematical modeling, laboratory and field experimentation, and societal impact assessment) has now narrowed to emphasis on the acquisition of field data of substantial quality and extent

  8. Reliability analysis of meteorological data registered during nuclear power plant normal operation

    International Nuclear Information System (INIS)

    Amado, V.; Ulke, A.; Marino, B.; Thomas, L.

    2011-01-01

    The atmosphere is the environment in which gaseous radioactive discharges from nuclear power plants are transported. It is therefore essential to have reliable meteorological information to characterize the dispersion and feed evaluation models and radiological environmental impact during normal operation of the plant as well as accidental releases. In this way it is possible to determine the effects on the environment and in humans. The basic data needed to represent adequately the local weather include air temperature, wind speed and direction, rainfall, humidity and pressure. On the other hand, specific data consistent with the used model is required to determine the turbulence, for instance, radiation, cloud cover and vertical temperature gradient. It is important that the recorded data are representative of the local meteorology. This requires, first, properly placed instruments, that should be kept in operation and undergoing maintenance on a regular basis. Second, but equally substantial, a thorough analysis of its reliability must be performed prior to storage and/or data processing. In this paper we present the main criteria to consider choosing the location of a meteorological tower in the area of a nuclear power plant and propose a methodology for assessing the reliability of recorded data. The methodology was developed from the analysis of meteorological data registered in nuclear power plants in Argentina. (authors) [es

  9. Drop Tower Physics

    Science.gov (United States)

    Dittrich, William A.

    2014-01-01

    The drop towers of yesteryear were used to make lead shot for muskets, as described in "The Physics Teacher" in April 2012. However, modern drop towers are essentially elevators designed so that the cable can "break" on demand, creating an environment with microgravity for a short period of time, currently up to nine seconds at…

  10. Wind turbine tower for storing hydrogen and energy

    Science.gov (United States)

    Fingersh, Lee Jay [Westminster, CO

    2008-12-30

    A wind turbine tower assembly for storing compressed gas such as hydrogen. The tower assembly includes a wind turbine having a rotor, a generator driven by the rotor, and a nacelle housing the generator. The tower assembly includes a foundation and a tubular tower with one end mounted to the foundation and another end attached to the nacelle. The tower includes an in-tower storage configured for storing a pressurized gas and defined at least in part by inner surfaces of the tower wall. In one embodiment, the tower wall is steel and has a circular cross section. The in-tower storage may be defined by first and second end caps welded to the inner surface of the tower wall or by an end cap near the top of the tower and by a sealing element attached to the tower wall adjacent the foundation, with the sealing element abutting the foundation.

  11. Structure of natural draft cooling towers, 1. Study on cooling tower shells

    Energy Technology Data Exchange (ETDEWEB)

    Ishioka, H; Sakamoto, Y; Tsurusaki, M; Koshizawa, K; Chiba, T [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan)

    1976-09-01

    Recently in Japan, demands for cooling tower systems have been increasing remarkably with the construction of large power plants and the legislation of environmental regulations. In view of the severe natural conditions in Japan such as strong wind and seismic loadings, etc., the establishment of the optimum design and construction method is essential for the building of safe and economical towers. In order to establish a comprehensive plan of a power plant cooling system of the appropriate structural type, the authors have made researches and experiments on design conditions, static and dynamic analyses, and comparative studies of various structural types such as reinforced concrete thin-shell structures, steel framed structures and composite shell segment structures, based on the investigation results of towers in Europe and America. These results are presented in three reports, the 1st of which concerns cooling tower shells as are herein described.

  12. Fire ants perpetually rebuild sinking towers

    Science.gov (United States)

    Phonekeo, Sulisay; Mlot, Nathan; Monaenkova, Daria; Hu, David L.; Tovey, Craig

    2017-07-01

    In the aftermath of a flood, fire ants, Solenopsis invicta, cluster into temporary encampments. The encampments can contain hundreds of thousands of ants and reach over 30 ants high. How do ants build such tall structures without being crushed? In this combined experimental and theoretical study, we investigate the shape and rate of construction of ant towers around a central support. The towers are bell shaped, consistent with towers of constant strength such as the Eiffel tower, where each element bears an equal load. However, unlike the Eiffel tower, the ant tower is built through a process of trial and error, whereby failed portions avalanche until the final shape emerges. High-speed and novel X-ray videography reveal that the tower constantly sinks and is rebuilt, reminiscent of large multicellular systems such as human skin. We combine the behavioural rules that produce rafts on water with measurements of adhesion and attachment strength to model the rate of growth of the tower. The model correctly predicts that the growth rate decreases as the support diameter increases. This work may inspire the design of synthetic swarms capable of building in vertical layers.

  13. A highly efficient Francis turbine designed for energy recovery in cooling towers

    Directory of Open Access Journals (Sweden)

    Daqing Zhou

    2015-03-01

    Full Text Available In China, cooling water entering cooling towers still retains surplus pressure between 39,240 and 147,150 Pa. In order to utilize this wasted energy, it is suggested that the surplus water energy can be harnessed to drive a type of hydroturbine installed in the inner platform of cooling tower and make the fan rotate via its coupled shafts. However, conventional hydroturbines are not suited for this job because of their low efficiency or unmatched rotating speed with that of the fan under the operating conditions of cooling towers. In this article, according to the requirements of turbine work environment in cooling towers, a new type of hydroturbine, Francis turbine with ultra-low specific speed (ns  = 50 m.kW, was designed to replace the fan motor in a cooling tower. Primarily, the shape, position, and number of runner blades were designed and optimized through theoretical analyses and computational fluid dynamics simulations. Additionally, metal elliptical volute and single-row ring guide vanes were applied to scale down the structural dimensions. Finally, the optimal scheme of the new Francis turbine was proven to have a high efficiency of 88% and good operation stability through testing of a physical model and can achieve the goal of harvesting renewable energy in the cooling tower.

  14. Dry cross-flow cooling tower

    Energy Technology Data Exchange (ETDEWEB)

    Fordyce, H E

    1975-01-23

    The invention deals with dry cooling towers in particular a circular cooling tower of the mechanical-draught construction whose operating characteristics should be independent of the wind direction. The recycling of the hot air should be as low as possible without necessitating high fan or natural-draught shafts, so that the costs of the tower can be brought down to a minimum.

  15. Applied Meteorology Unit (AMU)

    Science.gov (United States)

    Bauman, William; Crawford, Winifred; Barrett, Joe; Watson, Leela; Wheeler, Mark

    2010-01-01

    This report summarizes the Applied Meteorology Unit (AMU) activities for the first quarter of Fiscal Year 2010 (October - December 2009). A detailed project schedule is included in the Appendix. Included tasks are: (1) Peak Wind Tool for User Launch Commit Criteria (LCC), (2) Objective Lightning Probability Tool, Phase III, (3) Peak Wind Tool for General Forecasting, Phase II, (4) Upgrade Summer Severe Weather Tool in Meteorological Interactive Data Display System (MIDDS), (5) Advanced Regional Prediction System (ARPS) Data Analysis System (ADAS) Update and Maintainability, (5) Verify 12-km resolution North American Model (MesoNAM) Performance, and (5) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) Graphical User Interface.

  16. Cooling tower

    Energy Technology Data Exchange (ETDEWEB)

    Norbaeck, P; Heneby, H

    1976-01-22

    Cooling towers to be transported on road vehicles as a unit are not allowed to exceed certain dimensions. In order to improve the efficiency of such a cooling tower (of cross-flow design and box-type body) with given dimensions, it is proposed to arrange at least one of the scrubbing bodies displaceable within a module or box. Then it can be moved out of the casing into working position, thereby increasing the front surface available for the inlet of air (and with it the efficiency) by nearly a factor of two.

  17. Integration of Small Solar tower Systems into Distributed Power Islands

    Energy Technology Data Exchange (ETDEWEB)

    Romero, M.; Marcos, M. J.; Tellez, F. M.; Blanco, M.; Fernandez, V.; Baonza, F.; Berger, S. [Ciemat, Madrid (Spain)

    2000-07-01

    One of the short-term priorities for renewable energies in Europe is their integration for local power supply into communities and energy islands (blocks of buildings, new neighborhoods in residential areas, shopping centers, hospitals, recreational areas, eco-paks, small rural areas or isolated ones such as islands or mountain communities). Following this strategy, the integration of small tower fields into so-called MIUS (Modular Integrated Utility Systems) is proposed. This application strongly influences field concepts leadings to modular multi-tower systems able to more closely track demand, meet reliability requirements with fewer megawatts of installed power and spread construction costs over time after output has begum. In addition, integration into single-cycle high-efficiency gas turbines plus waste-heat applications clearly increments the solar share. The chief questions are whether solar towers can be redesigned for such distributed markets and the keys to their feasibility. This paper includes the design and performance analysis of a 1.36-MW plant and integration in the MIUS system, as well as the expected cost of electricity and a sensitivity analysis of the small tower plant's performance with design parameters like heliostat configuration and tower height. A practical application is analyzed for a shopping center with 85% power demand during day-time by using a hybrid solar tower and a gas turbine producing electricity and waste heat for hot water and heating and cooling of spaces. The operation mode proposed is covering night demand with power from the grid and solar-gas power island mode during 14 hours daytime with a maximum power production of 1.36 MW. (Author) 26 refs.

  18. Integration of Small Solar Tower Systems Into Distributed Power Islands

    International Nuclear Information System (INIS)

    Romero, M.; Marcos, M. J.; Tellez, F. M.; Blanco, M.; Fernandez, V.; Baonza, F.; Berger, S.

    1999-01-01

    One of the short-term priorities for renewable energies in Europe is their integration for local power supply into communities and energy islands (blocks of buildings, new neighborhoods in residential areas, shopping centers, hospitals, recreational areas, eco-parks, small rural areas or isolated ones such as islands or mountain communities). Following this strategy, the integration of small tower fields into so-called MIUS (Modular Integrated Utility Systems) is proposed. This application strongly influences field concepts leading to modular multi-tower systems able to more closely track demand, meet reliability requirements with fewer megawatts of installed power and spread construction costs over time after output has begun. In addition, integration into single-cycle high-efficiency gas turbines plus waste-heat applications clearly increments the solar share. The chief questions are whether solar towers can be redesigned for such distributed markets and the keys to their feasibility. This paper includes the design and performance analysis of a 1.36-MW plant and integration in the MIUS system, as well as the expected cost of electricity and a sensitivity analysis of the small tower plant's performance with design parameters like heliostats configuration and tower height. A practical application is analyzed for a shopping center with 85% power demand during day-time by using a hybrid solar tower and a gas turbine producing electricity and waste heat for hot water and heating and cooling of spaces. The operation mode proposed is covering night demand with power from the grid and solar-gas power island mode during 14 hours daytime with a maximum power production of 1.36 MW. (Author) 26 refs

  19. Cooling towers

    International Nuclear Information System (INIS)

    Korik, L.; Burger, R.

    1992-01-01

    What is the effect of 0.6C (1F) temperature rise across turbines, compressors, or evaporators? Enthalpy charts indicate for every 0.6C (1F) hotter water off the cooling tower will require an additional 2 1/2% more energy cost. Therefore, running 2.2C (4F) warmer due to substandard cooling towers could result in a 10% penalty for overcoming high heads and temperatures. If it costs $1,250,000.00 a year to operate the system, $125,000.00 is the energy penalty for hotter water. This paper investigates extra fuel costs involved in maintaining design electric production with cooling water 0.6C (1F) to 3C (5.5F) hotter than design. If design KWH cannot be maintained, paper will calculate dollar loss of saleable electricity. The presentation will conclude with examining the main causes of deficient cold water production. State-of-the-art upgrading and methodology available to retrofit existing cooling towers to optimize lower cooling water temperatures will be discussed

  20. Aerodynamical errors on tower mounted wind speed measurements due to the presence of the tower

    Energy Technology Data Exchange (ETDEWEB)

    Bergstroem, H. [Uppsala Univ. (Sweden). Dept. of Meteorology; Dahlberg, J.Aa. [Aeronautical Research Inst. of Sweden, Bromma (Sweden)

    1996-12-01

    Field measurements of wind speed from two lattice towers showed large differences for wind directions where the anemometers of both towers should be unaffected by any upstream obstacle. The wind speed was measured by cup anemometers mounted on booms along the side of the tower. A simple wind tunnel test indicates that the boom, for the studied conditions, could cause minor flow disturbances. A theoretical study, by means of simple 2D flow modelling of the flow around the mast, demonstrates that the tower itself could cause large wind flow disturbances. A theoretical study, based on simple treatment of the physics of motion of a cup anemometer, demonstrates that a cup anemometer is sensitive to velocity gradients across the cups and responds clearly to velocity gradients in the vicinity of the tower. Comparison of the results from the theoretical study and field tests show promising agreement. 2 refs, 8 figs

  1. Long-term Measurements of Summer-time Ozone at the Walnut Grove Tower - Understanding Trends in the Boundary Layer

    Science.gov (United States)

    Mahmud, A.; Di, P.; Mims, D.; Avise, J.; DaMassa, J.; Kaduwela, A. P.

    2015-12-01

    The California Air Resources Board (CARB) has been monitoring boundary layer ozone at the Walnut Grove Tower (WGT) since 1996 for investigating regional transport and vertical profile. Walnut Grove is located between Sacramento and Stockton, CA in the Sacramento - San Joaquin Delta. Sampling inlets are positioned at 30-ft, 400-ft, 800-ft, 1200-ft and 1600-ft levels of the 2000-ft tower, which is one of the tallest monitoring towers in the Western US. Ozone, ambient temperature, wind speed, and wind direction are simultaneously measured at each level, and reported as hourly averages. The current study included analyses of available ozone and corresponding meteorological data for the months of June - September from 1996 - 2014 with objectives to: 1) explore trends and inter-annual variability of ozone, 2) examine any correlations between ozone and meteorological parameters, 3) understand interactions of ozone measured at various levels, and 4) assess how well a regulatory state-of-the-science air quality model such as the Community Multi-scale Air Quality Model (CMAQ) captures observation. Daily 1-hr maximum ozone has been consistently decreasing during the 1996 - 2014 period at a rate of ~1 ppb per year. This indicates that CARB's measures to control ambient ozone have been effective over the past years. Evolution of the vertical profile throughout the day shows that ozone is fairly homogeneously mixed between 1 - 5 pm, when mixing height typically reaches the maximum. Ozone at 30-ft shows the greatest variability because of its proximity to the ground and emissions sources - rises faster during morning hours (7 - 10 am) and declines more rapidly during evening hours (7 - 10 pm) compared to other levels. Air masses reaching the tower are predominantly southwesterly (247 - 257 deg.) at the bottom, and southwesterly to slightly northwesterly (254 - 302 deg.) at top levels. Daily 1-hr maximum ozone was negatively correlated with wind speed (i.e. ozone was high under

  2. Collapse and pull - down analysis of high voltage electricity transmission towers subjected to cyclonic wind

    International Nuclear Information System (INIS)

    Ahmed, Ammar; Arthur, Craig; Edwards, Mark

    2010-01-01

    Bulk electricity transmission lines are linear assets that can be very exposed to wind effects, particularly where they traverse steep topography or open coastal terrain in cyclonic regions. Interconnected nature of the lattice type towers and conductors also, present complex vulnerabilities. These relate to the direction of wind attack to the conductors and the cascading failure mechanisms in which the failure of a single tower has cascading effects on neighbouring towers. Such behaviour is exacerbated by the finely tuned nature of tower design which serves to minimize cost and reserve strength at design wind speeds. There is a clear need to better quantify the interdependent vulnerabilities of these critical infrastructure assets in the context of the severe wind hazard. This paper presents a novel methodology developed for the Critical Infrastructure Protection Modelling and Analysis (CIPMA) capability for assessing local wind speeds and the likelihood of tower failure for a range of transmission tower and conductor types. CIPMA is a program managed by the Federal Attorney-General's Department and Geoscience Australia is leading the technical development. The methodology then involves the development of heuristically derived vulnerability models that are consistent with Australian industry experience and full-scale static tower testing results, considering isolated tower loss along with three interdependent failure mechanisms to give overall likelihoods of failure.

  3. Cooling towers of nuclear power plants

    International Nuclear Information System (INIS)

    Mikyska, L.

    1986-01-01

    The specifications are given of cooling towers of foreign nuclear power plants and a comparison is made with specifications of cooling towers with natural draught in Czechoslovak nuclear power plants. Shortcomings are pointed out in the design of cooling towers of Czechoslovak nuclear power plants which have been derived from conventional power plant design. The main differences are in the adjustment of the towers for winter operation and in the designed spray intensity. The comparison of selected parameters is expressed graphically. (J.B.)

  4. Cooling tower modification for intermittent operation

    International Nuclear Information System (INIS)

    Midkiff, W.S.

    1975-03-01

    One of the cooling towers at Los Alamos Scientific Laboratory is being operated intermittently. The cooling tower has been modified to restrict air flow and to keep the tower from drying out. The modifications are relatively inexpensive, simple to operate, and have proved effective. (U.S.)

  5. The continuous tower of scalar fields as a system of interacting dark matter–dark energy

    International Nuclear Information System (INIS)

    Santos, Paulo

    2015-01-01

    This paper aims to introduce a new parameterisation for the coupling Q in interacting dark matter and dark energy models by connecting said models with the Continuous Tower of Scalar Fields model. Based upon the existence of a dark matter and a dark energy sectors in the Continuous Tower of Scalar Fields, a simplification is considered for the evolution of a single scalar field from the tower, validated in this paper. This allows for the results obtained with the Continuous Tower of Scalar Fields model to match those of an interacting dark matter–dark energy system, considering that the energy transferred from one fluid to the other is given by the energy of the scalar fields that start oscillating at a given time, rather than considering that the energy transference depends on properties of the whole fluids that are interacting.

  6. Component for articulated offshore loading towers

    Energy Technology Data Exchange (ETDEWEB)

    Backhaus, H.

    1980-09-01

    The construction of offshore natural gas liquefaction plants must be regarded as technically feasible and the marketing prospects for LNG - a source of clean burning energy - appear excellent. Nevertheless, the optimum loading procedure for LNG tankers in the - sometimes adverse - offshore environment is still a matter under discussion by the experts - with a tendency to adopt and adapt well-proven components from the offshore crude oil sector. Here, articulated towers are in use for tankerloading and the crude oil is pumped at ambient temperature through the cardan joint of the tower itself. In the case of the cryogenic liquid LNG, this method would entail intolerable risks. Leaks and subsequent LNG spills within the tower joint will cause low temperature-embrittlement and most likely damage the cardan connection at the tower's base plate on the sea bed. The described submarine joint for ultra-cold liquids, which has the same cardanic properties as the cardan joint of the tower is completely separated from the latter. Thus a cryogenic leakage in this submarine joint will under no circumstance reach and affect the tower cardan.

  7. Radio Transmitters and Tower Locations, Layer includes all towers identified visually and include cellular and other communication towers., Published in 2008, 1:1200 (1in=100ft) scale, Noble County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Radio Transmitters and Tower Locations dataset current as of 2008. Layer includes all towers identified visually and include cellular and other communication towers..

  8. Legionella in industrial cooling towers: monitoring and control strategies.

    Science.gov (United States)

    Carducci, A; Verani, M; Battistini, R

    2010-01-01

    Legionella contamination of industrial cooling towers has been identified as the cause of sporadic cases and outbreaks of legionellosis among people living nearby. To evaluate and control Legionella contamination in industrial cooling tower water, microbiological monitoring was carried out to determine the effectiveness of the following different disinfection treatments: (i) continuous chlorine concentration of 0.01 ppm and monthly chlorine shock dosing (5 ppm) on a single cooling tower; (ii) continuous chlorine concentration of 0.4 ppm and monthly shock of biocide P3 FERROCID 8580 (BKG Water Solution) on seven towers. Legionella spp. and total bacterial count (TBC) were determined 3 days before and after each shock dose. Both strategies demonstrated that when chlorine was maintained at low levels, the Legionella count grew to levels above 10(4) CFU l(-1) while TBC still remained above 10(8 )CFU l(-1). Chlorine shock dosing was able to eliminate bacterial contamination, but only for 10-15 days. Biocide shock dosing was also insufficient to control the problem when the disinfectant concentration was administered at only one point in the plant and at the concentration of 30 ppm. On the other hand, when at a biocide concentration of 30 or 50 ppm was distributed throughout a number of points, depending on the plant hydrodynamics, Legionella counts decreased significantly and often remained below the warning limit. Moreover, the contamination of water entering the plant and the presence of sediment were also important factors for Legionella growth. For effective decontamination of outdoor industrial cooling towers, disinfectants should be distributed in a targeted way, taking into account the possible sources of contamination. The data of the research permitted to modify the procedure of disinfection for better reduce the water and aerosol contamination and consequently the exposure risk.

  9. The future cooling tower; Fremtidens koeletaarn

    Energy Technology Data Exchange (ETDEWEB)

    Ibsen, C.H. (Vestas Aircoil A/S, Lem St. (Denmark)); Schneider, P. (Teknologisk Institut, AArhus (Denmark)); Haaning, N. (Ramboell A/S, Copenhagen (Denmark)); Lund, K. (Nyrup Plast A/S, Nyrup (Denmark)); Soerensen, Ole (MultiWing A/S, Vedbaek (Denmark)); Dalsgaard, T. (Silhorko A/S, Skanderborg (Denmark)); Pedersen, Michael (Skive Kommune, Skive (Denmark))

    2011-03-15

    This project has designed and built a pilot-scale cooling tower with an output of up to 100 kW for which good correlation has been ascertained between measured and calculated values for output and pressure loss. The new cooling tower will save approximately 15% of electricity consumption compared with the widespread dry coolers. The pilot tower uses rainwater so that both water consumption and electricity consumption are saved in softening plants. On the basis of this cooling tower, models have been made and these have been implemented in PackCalc II in order to calculate electricity and other operating savings. (Energy 11)

  10. Dynamic interaction effects in cooling tower groups

    International Nuclear Information System (INIS)

    Riera, J.D.

    1984-01-01

    A theoretical and experimental determination of the dynamic response of reinforced concrete cooling towers, taking into consideration group effects, are described. The results for an individual tower are thoroughly examined. A complete analysis is then performed for the critical wind orientations, for each tower in a six towers group. It's shown that ignoring group effects in the analysis may lead to a significant underestimation of the structural response. (E.G.) [pt

  11. Effects of nearby surface features on wind speed at a nuclear plant meteorological station

    International Nuclear Information System (INIS)

    Nielsen, N.A.; Goodwin, R.J.; Pittman, D.E.

    1984-01-01

    There is a definite cause and effect relationship between the trees in the vicinity of the meteorological tower and the wind speed at the 10-meter level on the meteorological tower. For the affected directions, horizontal wind speed is significantly reduced below what it would be for that level if the trees were not present. This effect is only slightly less for the 10:1 exposure achieved with the 1977 tree clearing, which illustrates that meeting this commonly accepted distance to height ratio does not assure representativeness of 10-meter data collected at a nuclear plant site. The somewhat stronger effect for winds from the south through southwest directions may be partly attributable to the abrupt change in roughness and elevation encountered by air moving at an angle or directly across the reservoir, which is 3.5 to 5.0 kilometers wide at this site. This general reduction in wind speed values below what would be expected at the plant location will result in biased dispersion estimates. Calculated relative concentration values for releases treated as ground-level or building-wake releases would be larger than actual concentrations. While this would provide conservative concentration values, radioactive plume transport calculations would be nonconservative. The calculated, or predicted, transport rate would be slower than the actual transport rate. Such local biases affecting the spatial representativeness of airflow at 10 meters are a primary reason for TVA's decision to use 46-meter wind data for ground-level transport and diffusion modeling in its radiological emergency preparedness program

  12. Overall analysis of meteorological information in the Daeduk nuclear complex

    Energy Technology Data Exchange (ETDEWEB)

    Han, Moon Hee; Lee, Young Bok; Kim, Eun Han; Seo, Kyung Seok; Hwang, Wan Tae [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-12-01

    Inspection and repair of tower structure and lift, instrument calibration have been done. Wireless data transmission to MIPS(Meteorological Information Processing System) has been done after collection in the DAS where environmental assessment can be done by the developed simulation programs in both cases of normal operation and emergency. Wind direction, wind speed, temperature, humidity at 67m, 27m, and 10m height and temperature, humidity, atmospheric pressure, solar radiation, precipitation, and visibility at surface have been measured and analyzed with statistical methods. At the site, the prevailing wind directions were SW in spring and summer, NNW in winter season. The calm distributed 28.6% at 67m, 20.5% at 27m, 39.2% at 10m height. 9 tabs., 4 figs., 6 refs. (Author).

  13. Cooling towers principles and practice

    CERN Document Server

    Hill, G B; Osborn, Peter D

    1990-01-01

    Cooling Towers: Principles and Practice, Third Edition, aims to provide the reader with a better understanding of the theory and practice, so that installations are correctly designed and operated. As with all branches of engineering, new technology calls for a level of technical knowledge which becomes progressively higher; this new edition seeks to ensure that the principles and practice of cooling towers are set against a background of up-to-date technology. The book is organized into three sections. Section A on cooling tower practice covers topics such as the design and operation of c

  14. Proceedings: Cooling tower and advanced cooling systems conference

    International Nuclear Information System (INIS)

    1995-02-01

    This Cooling Tower and Advanced Cooling Systems Conference was held August 30 through September 1, 1994, in St. Petersburg, Florida. The conference was sponsored by the Electric Power Research Institute (EPRI) and hosted by Florida Power Corporation to bring together utility representatives, manufacturers, researchers, and consultants. Nineteen technical papers were presented in four sessions. These sessions were devoted to the following topics: cooling tower upgrades and retrofits, cooling tower performance, cooling tower fouling, and dry and hybrid systems. On the final day, panel discussions addressed current issues in cooling tower operation and maintenance as well as research and technology needs for power plant cooling. More than 100 people attended the conference. This report contains the technical papers presented at the conference. Of the 19 papers, five concern cooling tower upgrades and retrofits, five to cooling tower performance, four discuss cooling tower fouling, and five describe dry and hybrid cooling systems. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  15. Instantaneous-to-daily GPP upscaling schemes based on a coupled photosynthesis-stomatal conductance model: correcting the overestimation of GPP by directly using daily average meteorological inputs.

    Science.gov (United States)

    Wang, Fumin; Gonsamo, Alemu; Chen, Jing M; Black, T Andrew; Zhou, Bin

    2014-11-01

    Daily canopy photosynthesis is usually temporally upscaled from instantaneous (i.e., seconds) photosynthesis rate. The nonlinear response of photosynthesis to meteorological variables makes the temporal scaling a significant challenge. In this study, two temporal upscaling schemes of daily photosynthesis, the integrated daily model (IDM) and the segmented daily model (SDM), are presented by considering the diurnal variations of meteorological variables based on a coupled photosynthesis-stomatal conductance model. The two models, as well as a simple average daily model (SADM) with daily average meteorological inputs, were validated using the tower-derived gross primary production (GPP) to assess their abilities in simulating daily photosynthesis. The results showed IDM closely followed the seasonal trend of the tower-derived GPP with an average RMSE of 1.63 g C m(-2) day(-1), and an average Nash-Sutcliffe model efficiency coefficient (E) of 0.87. SDM performed similarly to IDM in GPP simulation but decreased the computation time by >66%. SADM overestimated daily GPP by about 15% during the growing season compared to IDM. Both IDM and SDM greatly decreased the overestimation by SADM, and improved the simulation of daily GPP by reducing the RMSE by 34 and 30%, respectively. The results indicated that IDM and SDM are useful temporal upscaling approaches, and both are superior to SADM in daily GPP simulation because they take into account the diurnally varying responses of photosynthesis to meteorological variables. SDM is computationally more efficient, and therefore more suitable for long-term and large-scale GPP simulations.

  16. Estimating rice yield related traits and quantitative trait loci analysis under different nitrogen treatments using a simple tower-based field phenotyping system with modified single-lens reflex cameras

    Science.gov (United States)

    Naito, Hiroki; Ogawa, Satoshi; Valencia, Milton Orlando; Mohri, Hiroki; Urano, Yutaka; Hosoi, Fumiki; Shimizu, Yo; Chavez, Alba Lucia; Ishitani, Manabu; Selvaraj, Michael Gomez; Omasa, Kenji

    2017-03-01

    Application of field based high-throughput phenotyping (FB-HTP) methods for monitoring plant performance in real field conditions has a high potential to accelerate the breeding process. In this paper, we discuss the use of a simple tower based remote sensing platform using modified single-lens reflex cameras for phenotyping yield traits in rice under different nitrogen (N) treatments over three years. This tower based phenotyping platform has the advantages of simplicity, ease and stability in terms of introduction, maintenance and continual operation under field conditions. Out of six phenological stages of rice analyzed, the flowering stage was the most useful in the estimation of yield performance under field conditions. We found a high correlation between several vegetation indices (simple ratio (SR), normalized difference vegetation index (NDVI), transformed vegetation index (TVI), corrected transformed vegetation index (CTVI), soil-adjusted vegetation index (SAVI) and modified soil-adjusted vegetation index (MSAVI)) and multiple yield traits (panicle number, grain weight and shoot biomass) across a three trials. Among all of the indices studied, SR exhibited the best performance in regards to the estimation of grain weight (R2 = 0.80). Under our tower-based field phenotyping system (TBFPS), we identified quantitative trait loci (QTL) for yield related traits using a mapping population of chromosome segment substitution lines (CSSLs) and a single nucleotide polymorphism data set. Our findings suggest the TBFPS can be useful for the estimation of yield performance during early crop development. This can be a major opportunity for rice breeders whom desire high throughput phenotypic selection for yield performance traits.

  17. Wind Turbine Tower Vibration Modeling and Monitoring by the Nonlinear State Estimation Technique (NSET

    Directory of Open Access Journals (Sweden)

    Peng Guo

    2012-12-01

    Full Text Available With appropriate vibration modeling and analysis the incipient failure of key components such as the tower, drive train and rotor of a large wind turbine can be detected. In this paper, the Nonlinear State Estimation Technique (NSET has been applied to model turbine tower vibration to good effect, providing an understanding of the tower vibration dynamic characteristics and the main factors influencing these. The developed tower vibration model comprises two different parts: a sub-model used for below rated wind speed; and another for above rated wind speed. Supervisory control and data acquisition system (SCADA data from a single wind turbine collected from March to April 2006 is used in the modeling. Model validation has been subsequently undertaken and is presented. This research has demonstrated the effectiveness of the NSET approach to tower vibration; in particular its conceptual simplicity, clear physical interpretation and high accuracy. The developed and validated tower vibration model was then used to successfully detect blade angle asymmetry that is a common fault that should be remedied promptly to improve turbine performance and limit fatigue damage. The work also shows that condition monitoring is improved significantly if the information from the vibration signals is complemented by analysis of other relevant SCADA data such as power performance, wind speed, and rotor loads.

  18. LBA-ECO CD-10 Temperature Profiles at km 67 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — ABSTRACT: This data set contains a single text file which reports temperature measurements at the Para Western (Santarem) - km 67, Primary Forest Tower Site. This...

  19. A drilling rig tower

    Energy Technology Data Exchange (ETDEWEB)

    Mironov, A.A.; Barashkov, V.A.; Bulgakov, E.S.; Kuldoshin, I.P.; Lebedev, A.I.; Papin, N.M.; Rebrik, B.M.; Sirotkin, N.V.

    1981-05-23

    Presentation is made of a drilling rig tower, comprising a gantry, a support shaft with a bracing strut and drawings out, and turn buckles. In order to increase the reliability of the tower in operation, to decrease the over all dimensions in a transport position, and to decrease the amount of time taken to transfer the tower from an operational position into a transportable one, and vice versa, the tower is equipped with a rotary frame made in the form of a triangular prism, whose lateral edges are connected by hinges: the first one with the lower part of the support shaft, the second with the gantry, and the third one to the upper part of the support shaft by means of the drawings out. The large boundary of the rotary frame is connected by a hinge to the support shaft by means of a bracing strut, which is equipped with a slide block connected to it by a hinge, and the rotary frame has a guide for the slide block reinforced to it on the large boundary. Besides this, the lateral edge of the rotary frame is connected to the gantry by means of turn buckles.

  20. The Design of Akhmat Tower

    Science.gov (United States)

    Beardsley, Sara; Stochetti, Alejandro; Cerone, Marc

    2018-03-01

    Akhmat Tower is a 435m supertall building designed by Adrian Smith + Gordon Gill Architecture. It is currently under construction in the city of Grozny, in the Chechen Republic, in the North Caucasus region of Russia. The design of the tower was done during a collaborative process by a multi-disciplinary architectural and engineering team, based primarily in the United States and Russia. During this process, the designers considered many factors including, most primarily, the cultural and historical context, the structural requirements given the high seismicity of the region, and the client's programmatic needs. The resulting crystalline-shaped tower is both an aesthetic statement and a performative architectural solution which will be a new landmark for Chechnya. "The Design of Akhmat Tower" describes in detail the design process including structural considerations, exterior wall design, building program, interior design, the tuned mass damper, and the use of building information modeling.

  1. Study on Tower Models for EHV Transmission Line

    Directory of Open Access Journals (Sweden)

    Xu Bao-Qing

    2016-01-01

    Full Text Available Lightning outage accident is one of the main factors that threat seriously the safe and reliable operation of power system. So it is very important to establish reasonable transmission tower model and evaluate the impulse response characteristic of lightning wave traveling on the transmission tower properly for determining reliable lightning protection performance. With the help of Electromagnetic Transient Program (EMTP, six 500kV tower models are built. Aiming at one line to one transformer operating mode of 500kV substation, the intruding wave overvoltage under different tower models is calculated. The effect of tower model on intruding overvoltage has been studied. The results show that different tower models can result in great differences to the calculation results. Hence, reasonable selection of the tower model in the calculation of back- strike intruding wave is very important.

  2. Performance characteristics of counter flow wet cooling towers

    International Nuclear Information System (INIS)

    Khan, Jameel-Ur-Rehman; Yaqub, M.; Zubair, Syed M.

    2003-01-01

    Cooling towers are one of the biggest heat and mass transfer devices that are in widespread use. In this paper, we use a detailed model of counter flow wet cooling towers in investigating the performance characteristics. The validity of the model is checked by experimental data reported in the literature. The thermal performance of the cooling towers is clearly explained in terms of varying air and water temperatures, as well as the driving potential for convection and evaporation heat transfer, along the height of the tower. The relative contribution of each mode of heat transfer rate to the total heat transfer rate in the cooling tower is established. It is demonstrated with an example problem that the predominant mode of heat transfer is evaporation. For example, evaporation contributes about 62.5% of the total rate of heat transfer at the bottom of the tower and almost 90% at the top of the tower. The variation of air and water temperatures along the height of the tower (process line) is explained on psychometric charts

  3. Atmospheric cooling tower with reduced plume

    International Nuclear Information System (INIS)

    Gautier, D.M.; Lagoutte, A.

    1985-01-01

    The cooling tower, usable in thermal-electric power plants, has a vertical chimney having a central water tower fed with water to be cooled, a pipe network distributing water coming from the water tower and dispersing it in flows streaming down on a packing, and a basin to receive the water cooled by contact with an air flow passing through apertures at the lower part of the chimney and flowing up through the chimney. The cooling tower has inlet air pipes for the said apertures to a zone of the chimney situated beyond the streaming zone, the said pipes being arranged such their surface is swept by water to be cooled [fr

  4. LBA-ECO CD-10 Temperature Profiles at km 67 Tower Site, Tapajos National Forest

    Data.gov (United States)

    National Aeronautics and Space Administration — This data set contains a single text file which reports temperature measurements at the Para Western (Santarem) - km 67, Primary Forest Tower Site. This site is in...

  5. Control Towers in Supply Chain Management - Past and Future

    Directory of Open Access Journals (Sweden)

    Anna Trzuskawska-Grzesińska

    2017-02-01

    Full Text Available The global economy requires global supply chain management which relies on visibility and responsiveness. Determinants such as: information technology tools, process knowledge, sales and operations planning experiences, etc., enable the formation of theory and practice for the supply chain control tower concept. The goal of the research paper is to identify business examples of different approaches to the supply chain control tower in the past and initiate a discussion on their future. This paper synthesizes past control tower practices and identifies possible future trends. The author performed: literature analysis, three selected companies' case studies and comparative analyses. As the control towers evolve, while supply chains are transforming continuous, update from the market is needed. The research findings showed the selected companies, in the future, perceived control tower's activities as a potential source of revenue not just solely a source of cost and time optimization as well as a source of value added to customer. The researched control towers were built and still they are developed. The business frequently changes and requires control towers to be adjusted, reengineered and adaptive. The researched control towers are needed to keep control over supply chain while it is transforming. There is a differentiation between the supply chain control towers, logistic services control towers and reverse supply chain control towers. An integration mechanism between the control towers would be necessary to assure entire supply chain visibility and orchestration. The research also shows the knowledge gap regarding the control towers in supply chain, specially their possible configurations and future.

  6. SUMO: A small unmanned meteorological observer for atmospheric boundary layer research

    International Nuclear Information System (INIS)

    Reuder, J; Jonassen, M; Mayer, S; Brisset, P; Mueller, M

    2008-01-01

    A new system for atmospheric measurements in the lower troposphere has been developed and successfully tested. The presented Small Unmanned Meteorological Observer (SUMO) is based on a light-weighted commercially available model airplane, equipped with an autopilot and meteorological sensors for temperature, humidity and pressure. During the 5 week field campaign FLOHOF (Flow over and around HofsjoUkull) in Central Iceland the system has been successfully tested in July/August 2007. Atmospheric profiles of temperature, humidity, wind speed and wind direction have been determined up to 3500 m above ground. In addition the applicability of SUMO for horizontal surveys up to 4 km away from the launch site has been approved. During a 3 week campaign on and around Spitsbergen in February/March 2008 the SUMO system also proved its functionality under harsh polar conditions, reaching altitudes above 1500 m at ground temperatures of -20 deg. C and wind speeds up to 15 m s -1 . With its wingspan of 80 cm, its length of 75 cm and its weight of below 600 g, SUMO is easy to transport and operate even in remote areas. The direct material costs for one SUMO unit, including airplane, autopilot and sensors are below 1200 Euro. Assuming at least several tenths of flights for each airframe, SUMO provides a cost-efficient measurement system with a large potential to close the existing observational gap of reasonable atmospheric measurement systems in between meteorological masts/towers and radiosondes

  7. SUMO: A small unmanned meteorological observer for atmospheric boundary layer research

    Energy Technology Data Exchange (ETDEWEB)

    Reuder, J; Jonassen, M; Mayer, S [Geophysical Institute, University of Bergen, Allegaten 70, 5009 Bergen (Norway); Brisset, P [Ecole Nationale de l' Aviation Civile (ENAC), 7 avenue Edouard Belin, 31055 Toulouse (France); Mueller, M [Orleansstrasse 26a, 31135 Hildesheim (Germany)], E-mail: joachim.reuder@gfi.uib.no, E-mail: pascal.brisset@enac.fr, E-mail: marius.jonassen@gfi.uib.no, E-mail: martin@pfump.org, E-mail: stephanie.mayer@gfi.uib.no

    2008-05-01

    A new system for atmospheric measurements in the lower troposphere has been developed and successfully tested. The presented Small Unmanned Meteorological Observer (SUMO) is based on a light-weighted commercially available model airplane, equipped with an autopilot and meteorological sensors for temperature, humidity and pressure. During the 5 week field campaign FLOHOF (Flow over and around HofsjoUkull) in Central Iceland the system has been successfully tested in July/August 2007. Atmospheric profiles of temperature, humidity, wind speed and wind direction have been determined up to 3500 m above ground. In addition the applicability of SUMO for horizontal surveys up to 4 km away from the launch site has been approved. During a 3 week campaign on and around Spitsbergen in February/March 2008 the SUMO system also proved its functionality under harsh polar conditions, reaching altitudes above 1500 m at ground temperatures of -20 deg. C and wind speeds up to 15 m s{sup -1}. With its wingspan of 80 cm, its length of 75 cm and its weight of below 600 g, SUMO is easy to transport and operate even in remote areas. The direct material costs for one SUMO unit, including airplane, autopilot and sensors are below 1200 Euro. Assuming at least several tenths of flights for each airframe, SUMO provides a cost-efficient measurement system with a large potential to close the existing observational gap of reasonable atmospheric measurement systems in between meteorological masts/towers and radiosondes.

  8. Statistics Analysis Measures Painting of Cooling Tower

    Directory of Open Access Journals (Sweden)

    A. Zacharopoulou

    2013-01-01

    Full Text Available This study refers to the cooling tower of Megalopolis (construction 1975 and protection from corrosive environment. The maintenance of the cooling tower took place in 2008. The cooling tower was badly damaged from corrosion of reinforcement. The parabolic cooling towers (factory of electrical power are a typical example of construction, which has a special aggressive environment. The protection of cooling towers is usually achieved through organic coatings. Because of the different environmental impacts on the internal and external side of the cooling tower, a different system of paint application is required. The present study refers to the damages caused by corrosion process. The corrosive environments, the application of this painting, the quality control process, the measures and statistics analysis, and the results were discussed in this study. In the process of quality control the following measurements were taken into consideration: (1 examination of the adhesion with the cross-cut test, (2 examination of the film thickness, and (3 controlling of the pull-off resistance for concrete substrates and paintings. Finally, this study refers to the correlations of measurements, analysis of failures in relation to the quality of repair, and rehabilitation of the cooling tower. Also this study made a first attempt to apply the specific corrosion inhibitors in such a large structure.

  9. Improving performance and reducing costs of cooling towers

    International Nuclear Information System (INIS)

    Bartz, J.A.

    1992-01-01

    Cooling towers represent a significant capital investment at a steam electric power station. In addition, deficiencies in thermal performance can result in major operating penalties of fuel cost, replacement energy, and capacity addition. This paper summarizes two recent EPRI research projects aimed at reducing thermal performance deficiencies and decreasing installed costs of evaporative cooling towers. First, EPRI Research Project 2113, Cooling Tower Performance Prediction and Improvement, is summarized. This project has resulted in published data sets on the measured thermal performance characteristics of a variety of cooling tower packings, computer codes to predict tower performance, and computer code validation through large-scale tower performance measurements. Principal results are contained in an EPRIGEMS software module, Cooling Tower Advisor. This PC- based software contains a tutorial plus codes to predict tower thermal performance, arranged in a user-friendly format. The second EPRI effort, Research Project 2819-10/11, Fabric Structures for Power Plant Applications, has resulted in designs and costs of large structures with shells constructed of recently-developed fabrics. Primary power plant applications for such structures are the shells of natural draft cooling towers and coal-pile covers. Fabric structures offer low initial cost, acceptable life, and seismic superiority, among other advantages. Detailed conceptual designs and installed cost data are reviewed. 8 refs., 9 figs., 3 tabs

  10. Analysis of Ideal Towers for Tall Wind Applications

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, Katherine L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Damiani, Rick R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Roberts, Joseph O [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lantz, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-01-12

    Innovation in wind turbine tower design is of significant interest for future development of wind power plants. First, wind turbine towers account for a large portion of overall capital expenditures for wind power projects. Second, for low wind-resource regions of the world, the use of low-cost tall-tower technology has the potential to open new markets for development. This study investigates the relative potential of various tower configurations in terms of mass and cost. For different market applications and hub heights, idealized tall towers are designed and compared. The results show that innovation in wind turbine controls makes reaching higher hub heights with current technology economically viable. At the same time, new technologies hold promise for reducing tower costs as these technologies mature and hub heights reach twice the current average.

  11. Overall analysis of meteorological information in the Daeduk nuclear complex

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Han; Lee, Yung Bok; Han, Moon Heui; Suh, Kyung Suk; Tae, Hwang Won [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-01-01

    Inspection and repair of tower structure and lift, instrument calibration have been done. Wireless data transmission to MIPS(Meteorological Information Processing System) has been done after collection in the DAS where environmental assessment can be done by the developed simulation programs in both cases of normal operation and emergency. Wind direction, wind speed, temperature, humidity, at 67 m, 27 m, and 10 m height and temperature, humidity, atmospheric pressure, solar radiation, precipitation, and visibility at surface have been measured and analyzed with statistical methods. At the site, the prevailing wind directions were SW in spring and summer, N and NW in autumn and winter season. The calm distributed 13.6% at 67 m, 24.5% at 27 m, 40.8% at 10 m height. 4 figs, 9 tabs, 6 refs. (Author).

  12. Overall analysis of meteorological information in the Daeduk nuclear complex

    International Nuclear Information System (INIS)

    Kim, Eun Han; Lee, Yung Bok; Han, Moon Heui; Suh, Kyung Suk; Hwang Won Tae

    1995-01-01

    Inspection and repair of tower structure and lift, instrument calibration have been done. Wireless data transmission to MIPS(Meteorological Information Processing System) has been done after collection in the DAS where environmental assessment can be done by the developed simulation programs in both cases of normal operation and emergency. Wind direction, wind speed, temperature, humidity, at 67 m, 27 m, and 10 m height and temperature, humidity, atmospheric pressure, solar radiation, precipitation, and visibility at surface have been measured and analyzed with statistical methods. At the site, the prevailing wind directions were SW in spring and summer, N and NW in autumn and winter season. The calm distributed 13.6% at 67 m, 24.5% at 27 m, 40.8% at 10 m height. 4 figs, 9 tabs, 6 refs. (Author)

  13. Cooling towers for thermal power plants

    International Nuclear Information System (INIS)

    Chaboseau, J.

    1987-01-01

    After a brief recall on cooling towers testing and construction, this paper presents four examples of very large French nuclear power plant cooling towers, and one of an Australian thermal power plant [fr

  14. Lifting system and apparatus for constructing wind turbine towers

    Science.gov (United States)

    Livingston, Tracy; Schrader, Terry; Goldhardt, James; Lott, James

    2011-02-01

    The disclosed invention is utilized for mounting a wind turbine and blade assembly on the upper end of a wind turbine tower. The invention generally includes a frame or truss that is pivotally secured to the top bay assembly of the tower. A transverse beam is connected to the frame or truss and extends fore of the tower when the frame or truss is in a first position and generally above the tower when in a second position. When in the first position, a wind turbine or blade assembly can be hoisted to the top of the tower. The wind turbine or blade assembly is then moved into position for mounting to the tower as the frame or truss is pivoted to a second position. When the turbine and blade assembly are secured to the tower, the frame or truss is disconnected from the tower and lowered to the ground.

  15. The Schmehausen cable net cooling tower

    International Nuclear Information System (INIS)

    Schlaich, J.; Mayr, G.; Weber, P.; Jasch, E.

    1976-01-01

    The prototype of a large cable net shell as a natural-draught cooling tower for the THTR-300 is presented. Results of wind tunnel tests and calculations are given, and the capacity is discussed. Design features of the main components are presented in illustrations and are described with regard to the construction process of the cooling tower. Finally, it is shown that the cable net cooling tower is a suitable construction for large dimensions and caving-in or seismic areas. (orig./HP) [de

  16. Performance characteristics of a shower cooling tower

    International Nuclear Information System (INIS)

    Qi Xiaoni; Liu Zhenyan; Li Dandan

    2007-01-01

    This study was prompted by the need to design towers for applications in which, due to salt deposition on the packing and subsequent blockage, the use of tower packing is not practical. In contrast to conventional cooling towers, the cooling tower analyzed in this study is void of fill. By means of efficient atomization nozzles, a shower cooling tower (SCT) is possible to be applied in industry, which, in terms of water cooling, energy saving and equipment investing, is better than conventional packed cooling towers. However, no systematic thermodynamic numerical method could be found in the literature up to now. Based on the kinetic model and mass and heat transfer model, this paper has developed a one dimensional model for studying the motional process and evaporative cooling process occurring at the water droplet level in the SCT. The finite difference approach is used for three motional processes to obtain relative parameters in each different stage, and the possibility of the droplets being entrained outside the tower is fully analyzed. The accuracy of this model is checked by practical operational results from a full scale prototype in real conditions, and some exclusive factors that affect the cooling characteristics for the SCT are analyzed in detail. This study provides the theoretical foundation for practical application of the SCT in industry

  17. Atmospheric emissions from power plant cooling towers

    International Nuclear Information System (INIS)

    Micheletti, W.

    2006-01-01

    Power plant recirculated cooling systems (cooling towers) are not typically thought of as potential sources of air pollution. However, atmospheric emissions can be important considerations that may influence cooling tower design and operation. This paper discusses relevant U.S. environmental regulations for potential atmospheric pollutants from power plant cooling towers, and various methods for estimating and controlling these emissions. (orig.)

  18. The effect of a tall tower on flow and dispersion through a model urban neighborhood: part 2. Pollutant dispersion.

    Science.gov (United States)

    Brixey, Laurie A; Heist, David K; Richmond-Bryant, Jennifer; Bowker, George E; Perry, Steven G; Wiener, Russell W

    2009-12-01

    This article is the second in a two-paper series presenting results from wind tunnel and computational fluid dynamics (CFD) simulations of flow and dispersion in an idealized model urban neighborhood. Pollutant dispersion results are presented and discussed for a model neighborhood that was characterized by regular city blocks of three-story row houses with a single 12-story tower located at the downwind edge of one of these blocks. The tower had three significant effects on pollutant dispersion in the surrounding street canyons: drawing the plume laterally towards the tower, greatly enhancing the vertical dispersion of the plume in the wake of the tower, and significantly decreasing the residence time of pollutants in the wake of the tower. In the wind tunnel, tracer gas released in the avenue lee of the tower, but several blocks away laterally, was pulled towards the tower and lifted in the wake of the tower. The same lateral movement of the pollutant was seen in the next avenue, which was approximately 2.5 tower heights downwind of the tower. The tower also served to ventilate the street canyon directly in its wake more rapidly than the surrounding areas. This was evidenced by CFD simulations of concentration decay where the residence time of pollutants lee of the 12-story tower was found to be less than half the residence time behind a neighboring three-story building. This same phenomenon of rapid vertical dispersion lee of a tower among an array of smaller buildings was also demonstrated in a separate set of wind tunnel experiments using an array of cubical blocks. A similar decrease in the residence time was observed when the height of one block was increased.

  19. Biofouling control of industrial seawater cooling towers

    KAUST Repository

    Albloushi, Mohammed

    2017-11-01

    The use of seawater in cooling towers for industrial applications has much merit in the Gulf Cooperation Council countries due to the scarcity and availability of fresh water. Seawater make-up in cooling towers is deemed the most feasible because of its unlimited supply in coastal areas. Such latent-heat removal with seawater in cooling towers is several folds more efficient than sensible heat extraction via heat exchangers. Operational challenges such as scaling, corrosion, and biofouling are a major challenge in conventional cooling towers, where the latter is also a major issue in seawater cooling towers. Biofouling can significantly hamper the efficiency of cooling towers. The most popular methods used in cooling treatment to control biofouling are disinfection by chlorination. However, the disadvantages of chlorination are formation of harmful disinfection byproducts in the presence of high organic loading and safety concerns in the storage of chlorine gas. In this study, the research focuses on biofouling control in seawater cooling towers by investigating two different approaches. The first strategy addresses the use of alternative oxidants (i.e. ozone micro-bubbles and chlorine dioxide) in treatment of cooling towers. The second strategy investigates removing nutrients in seawater using granular activated carbon filter column and ultrafiltration to prevent the growth of microorganisms. Laboratory bench-scale tests in terms of temperature, cycle of concentration, dosage, etc. indicated that, at lower oxidant dosages (total residual oxidant (TRO) equivalent = 0.1 mg/l Cl2), chlorine dioxide had a better disinfection effect than chlorine and ozone. The performance of oxidizing biocides at pilot scale, operating at assorted conditions, showed that for the disinfectants tested, ozone could remove 95 % bioactivity of total number of bacteria and algae followed by chlorine dioxide at 85%, while conventional chlorine dosing only gave 60% reduction in bioactivities

  20. Mechanical Properties of UHPFRC Joint for FORIDA Wind Turbine Tower

    DEFF Research Database (Denmark)

    Sørensen, Eigil Verner

    FORIDA Development, Vestas and Aalborg University are currently undertaking the project “FORIDA Hybrid Towers – The towers for next generation of wind turbines”, aiming to develop a new wind turbine tower structure (The FORIDA Tower) for very tall turbines. The tower is going to be a hybrid of ma...

  1. Damping of wind turbine tower vibrations

    DEFF Research Database (Denmark)

    Brodersen, Mark Laier; Pedersen, Mikkel Melters

    Damping of wind turbine vibrations by supplemental dampers is a key ingredient for the continuous use of monopiles as support for offshore wind turbines. The present thesis consists of an extended summary with four parts and appended papers [P1-P4] concerning novel strategies for damping of tower...... dominated vibrations.The first part of the thesis presents the theoretical framework for implementation of supplemental dampers in wind turbines. It is demonstrated that the feasibility of installing dampers at the bottom of the tower is significantly increased when placing passive or semiactive dampers...... in a stroke amplifying brace, which amplifies the displacement across the damper and thus reduces the desired level of damper force. For optimal damping of the two lowest tower modes, a novel toggle-brace concept for amplifying the bending deformation of the tower is presented. Numerical examples illustrate...

  2. Modality analysis of anchored ion exchange tower using Ansys

    International Nuclear Information System (INIS)

    Li Liang; Lei Zeyong

    2008-01-01

    Ion exchange towers are exposed to serious damage in the event of earthquakes. It is very necessary to study the seismic resistance of ion exchange tower. A finite element model of anchored ion exchange tower was made by Ansys. The first 10 ranks of inherent frequencies were made out, and three-dimensional main vibratory model figures were drawn out. The maximal stress along x-axis and y-axis and the main displacement were found at the bottom part of the wall of tower junction with the pillars. It is concluded that the breakage of tower wall easily occurs at the bottom part of the wall of tower junction with the pillars. Therefore, it is very important to reinforce the junction of the tower body, and the strengthening plate should lie near the bottom of wall. (authors)

  3. Asbestos in cooling-tower waters. Final report

    International Nuclear Information System (INIS)

    Lewis, B.A.G.

    1979-03-01

    Water discharges from cooling towers constructed with asbestos fill were found to contain chrysotile--asbestos fibers at concentrations as high as 10 8 fibers/liter. The major source of these fibers, appears to be the components of the towers rather than the air drawn through the towers or the makeup water taken into the towers. Suggested mechanisms for the release of chrysotile fibers from cooling-tower fill include freeze-thaw cycles and dissolution of the cement due to acidic components of the circulating water. Ash- or other material-settling ponds were found to reduce asbestos-fiber concentrations in cooling-tower effluent. The literature reviewed did not support the case for a causal relationship between adverse human health effects and drinking water containing on the order of 10 6 chrysotile--asbestos fibers/liter; for this and other reasons, it is not presently suggested that the use of asbestos fill be discontinued. However, caution and surveillance are dictated by the uncertainties in the epidemiological studies, the absence of evidence for a safe threshold concentration in water, and the conclusive evidence for adverse effects from occupational exposure. It is recommended that monitoring programs be carried out at sites where asbestos fill is used; data from such programs can be used to determine whether any mitigative measures should be taken. On the basis of estimates made in this study, monitoring for asbestos in drift from cooling towers does not appear to be warranted

  4. ''Novel'' types of cooling towers for the power industry

    International Nuclear Information System (INIS)

    Mikyska, L.

    1991-01-01

    New types of cooling towers are beginning to be used abroad for the cooling circuits of nuclear power plants employing power generation units rated at 1,300 to 1,400 MW. These so-called water recovery cooling towers make use of natural draught without a droplet section. They are actually upgraded designs which were built in Europe as far back as 70 years ago. Because of the unsuitable materials then employed, these cooling towers fell into oblivion. Today, however, they are undergoing a renaissance. An upgraded design of these towers is described and compared with existing cooling towers with a droplet section. The feasibility of using these towers in Czechoslovak conditions is considered. (author)

  5. Summary of tower designs for large horizontal axis wind turbines

    Science.gov (United States)

    Frederick, G. R.; Savino, J. M.

    1986-01-01

    Towers for large horizontal axis wind turbines, machines with a rotor axis height above 30 meters and rated at more than 500 kW, have varied in configuration, materials of construction, type of construction, height, and stiffness. For example, the U.S. large HAWTs have utilized steel truss type towers and free-standing steel cylindrical towers. In Europe, the trend has been to use only free-standing and guyed cylindrical towers, but both steel and reinforced concrete have been used as materials of construction. These variations in materials of construction and type of construction reflect different engineering approaches to the design of cost effective towers for large HAWTs. Tower designs are the NASA/DOE Mod-5B presently being fabricated. Design goals and requirements that influence tower configuration, height and materials are discussed. In particular, experiences with United States large wind turbine towers are elucidated. Finally, current trends in tower designs for large HAWTs are highlighted.

  6. Health risks from exposure to Legionella in reclaimed water aerosols: Toilet flushing, spray irrigation, and cooling towers.

    Science.gov (United States)

    Hamilton, Kerry A; Hamilton, Mark T; Johnson, William; Jjemba, Patrick; Bukhari, Zia; LeChevallier, Mark; Haas, Charles N

    2018-05-01

    The use of reclaimed water brings new challenges for the water industry in terms of maintaining water quality while increasing sustainability. Increased attention has been devoted to opportunistic pathogens, especially Legionella pneumophila, due to its growing importance as a portion of the waterborne disease burden in the United States. Infection occurs when a person inhales a mist containing Legionella bacteria. The top three uses for reclaimed water (cooling towers, spray irrigation, and toilet flushing) that generate aerosols were evaluated for Legionella health risks in reclaimed water using quantitative microbial risk assessment (QMRA). Risks are compared using data from nineteen United States reclaimed water utilities measured with culture-based methods, quantitative PCR (qPCR), and ethidium-monoazide-qPCR. Median toilet flushing annual infection risks exceeded 10 -4 considering multiple toilet types, while median clinical severity infection risks did not exceed this value. Sprinkler and cooling tower risks varied depending on meteorological conditions and operational characteristics such as drift eliminator performance. However, the greatest differences between risk scenarios were due to 1) the dose response model used (infection or clinical severity infection) 2) population at risk considered (residential or occupational) and 3) differences in laboratory analytical method. Theoretical setback distances necessary to achieve a median annual infection risk level of 10 -4 are proposed for spray irrigation and cooling towers. In both cooling tower and sprinkler cases, Legionella infection risks were non-trivial at potentially large setback distances, and indicate other simultaneous management practices could be needed to manage risks. The sensitivity analysis indicated that the most influential factors for variability in risks were the concentration of Legionella and aerosol partitioning and/or efficiency across all models, highlighting the importance of

  7. Effect on the annual atmospheric dispersion factor of different diffusion parameters and meteorological data at nuclear power plant

    International Nuclear Information System (INIS)

    Hu Erbang; Yan Jiangyu; Wang Han; Xin Cuntian

    2003-01-01

    Based on the hourly metrological observing data of 100 m high tower during 1997-1999 at Tianwan Nuclear Power Plant (NPP) site and 1995-1997 in Fujian Huian NPP site, the effect on the annual atmospheric dispersion factor (AADF) of four different diffusion parameters (on-site measuring values, IAEA's, Briggs's and Pasquill's) are estimated. The analysis shows that the deviation between the results from IAEA's, Briggs's and on-site measured diffusion parameters is less than 20%. The effect on the AADF from different years' meteorological data also is estimated. (authors)

  8. Newton slopes for Artin-Schreier-Witt towers

    DEFF Research Database (Denmark)

    Davis, Christopher; Wan, Daqing; Xiao, Liang

    2016-01-01

    We fix a monic polynomial f(x)∈Fq[x] over a finite field and consider the Artin-Schreier-Witt tower defined by f(x); this is a tower of curves ⋯→Cm→Cm−1→⋯→C0=A1, with total Galois group Zp. We study the Newton slopes of zeta functions of this tower of curves. This reduces to the study of the Newton...... slopes of L-functions associated to characters of the Galois group of this tower. We prove that, when the conductor of the character is large enough, the Newton slopes of the L-function form arithmetic progressions which are independent of the conductor of the character. As a corollary, we obtain...

  9. Virtual Tower

    International Nuclear Information System (INIS)

    Wayne, R.A.

    1997-01-01

    The primary responsibility of an intrusion detection system (IDS) operator is to monitor the system, assess alarms, and summon and coordinate the response team when a threat is acknowledged. The tools currently provided to the operator are somewhat limited: monitors must be switched, keystrokes must be entered to call up intrusion sensor data, and communication with the response force must be maintained. The Virtual tower is an operator interface assembled from low-cost commercial-off-the-shelf hardware and software; it enables large amounts of data to be displayed in a virtual manner that provides instant recognition for the operator and increases assessment accuracy in alarm annunciator and control systems. This is accomplished by correlating and fusing the data into a 360-degree visual representation that employs color, auxiliary attributes, video, and directional audio to prompt the operator. The Virtual Tower would be a valuable low-cost enhancement to existing systems

  10. Mycobacteria in Finnish cooling tower waters.

    Science.gov (United States)

    Torvinen, Eila; Suomalainen, Sini; Paulin, Lars; Kusnetsov, Jaana

    2014-04-01

    Evaporative cooling towers are water systems used in, e.g., industry and telecommunication to remove excess heat by evaporation of water. Temperatures of cooling waters are usually optimal for mesophilic microbial growth and cooling towers may liberate massive amounts of bacterial aerosols. Outbreaks of legionellosis associated with cooling towers have been known since the 1980's, but occurrences of other potentially pathogenic bacteria in cooling waters are mostly unknown. We examined the occurrence of mycobacteria, which are common bacteria in different water systems and may cause pulmonary and other soft tissue infections, in cooling waters containing different numbers of legionellae. Mycobacteria were isolated from all twelve cooling systems and from 92% of the 24 samples studied. Their numbers in the positive samples varied from 10 to 7.3 × 10(4) cfu/L. The isolated species included M. chelonae/abscessus, M. fortuitum, M. mucogenicum, M. peregrinum, M. intracellulare, M. lentiflavum, M. avium/nebraskense/scrofulaceum and many non-pathogenic species. The numbers of mycobacteria correlated negatively with the numbers of legionellae and the concentration of copper. The results show that cooling towers are suitable environments for potentially pathogenic mycobacteria. Further transmission of mycobacteria from the towers to the environment needs examination. © 2013 APMIS. Published by John Wiley & Sons Ltd.

  11. Cellular Phone Towers, Tower locations and attributes generated from FCC anntenna registration database. Tower data was cross referenced with county zoning special use permits., Published in 2008, 1:600 (1in=50ft) scale, Waupaca County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Cellular Phone Towers dataset current as of 2008. Tower locations and attributes generated from FCC anntenna registration database. Tower data was cross referenced...

  12. The Small Unmanned Meteorological Observer SUMO. A new tool for atmospheric boundary layer research

    Energy Technology Data Exchange (ETDEWEB)

    Reuder, Joachim; Jonassen, Marius; Mayer, Stephanie [Bergen Univ. (Norway). Geophysical Inst.; Brisset, Pascal [Ecole Nationale de l' Aviation Civile (ENAC), Toulouse (France); Mueller, Martin [Martin Mueller Engineering, Hildesheim (Germany)

    2009-04-15

    The Small Unmanned Meteorological Observer SUMO has been developed as a cost-efficient measurement system with the aim to close the existing observational gap of atmospheric measurement systems in between meteorological masts/towers and radiosondes. The system is highly flexible and has the capability for in-situ ABL measurements with unique spatial and temporal resolution. SUMO is based on a light-weighted styrofoam model airplane, equipped with an autopilot system for autonomous flight missions and in its recent version with meteorological sensors for temperature, humidity and pressure. With its wingspan of 80 cm, its length of 75 cm and a total lift-off weight of 580 g, SUMO is easy to transport and operate even in remote areas with limited infrastructure. During several field campaigns in 2007 and 2008 the system has been successfully tested and operated. Atmospheric profiles of temperature, humidity, wind speed and wind direction have been determined up to 3500 m above ground during the FLOHOF (FLOw over and around HOFsjoekull) field campaign in Central Iceland in July/August 2007. During a 3 week campaign on and around Spitsbergen in February/March 2008 the SUMO system also proved its functionality under polar conditions, reaching altitudes above 1500 m even at ground temperatures of -20 C and wind speeds up to 15 m s{sup -1}. (orig.)

  13. Improving the efficiency of natural draft cooling towers

    International Nuclear Information System (INIS)

    Smrekar, J.; Oman, J.; Sirok, B.

    2006-01-01

    This study shows how the efficiency of a natural draft cooling tower can be improved by optimising the heat transfer along the cooling tower (CT) packing using a suitable water distribution across the plane area of the cooling tower. On the basis of cooling air measurements, it is possible to distribute the water in such a way that it approaches the optimal local water/air mass flow ratio and ensures the homogeneity of the heat transfer and a reduction of entropy generation, thus minimising the amount of exergy lost. The velocity and temperature fields of the air flow were measured with the aid of a remote control mobile robot unit that was developed to enable measurements at an arbitrary point above the spray zone over the entire plane area of the cooling tower. The topological structures of the moist air velocity profiles and the temperature profiles above the spray zone were used as input data for calculation of the local entropy generation in the tower. On the basis of the measured boundary conditions, a numerical analysis of the influence of the water distribution across the cooling tower's plane area on entropy generation and exergy destruction in the cooling tower was conducted

  14. Improving the efficiency of natural draft cooling towers

    Energy Technology Data Exchange (ETDEWEB)

    Smrekar, J. [Faculty of Mechanical Engineering, Askerceva 6, SI-1000 Ljubljana (Slovenia); Oman, J. [Faculty of Mechanical Engineering, Askerceva 6, SI-1000 Ljubljana (Slovenia)]. E-mail: janez.oman@fs.uni-lj.si; Sirok, B. [Faculty of Mechanical Engineering, Askerceva 6, SI-1000 Ljubljana (Slovenia)

    2006-06-15

    This study shows how the efficiency of a natural draft cooling tower can be improved by optimising the heat transfer along the cooling tower (CT) packing using a suitable water distribution across the plane area of the cooling tower. On the basis of cooling air measurements, it is possible to distribute the water in such a way that it approaches the optimal local water/air mass flow ratio and ensures the homogeneity of the heat transfer and a reduction of entropy generation, thus minimising the amount of exergy lost. The velocity and temperature fields of the air flow were measured with the aid of a remote control mobile robot unit that was developed to enable measurements at an arbitrary point above the spray zone over the entire plane area of the cooling tower. The topological structures of the moist air velocity profiles and the temperature profiles above the spray zone were used as input data for calculation of the local entropy generation in the tower. On the basis of the measured boundary conditions, a numerical analysis of the influence of the water distribution across the cooling tower's plane area on entropy generation and exergy destruction in the cooling tower was conducted.

  15. TacTower

    DEFF Research Database (Denmark)

    Rasmussen, Majken Kirkegaard; Jürgensen, Christine

    2009-01-01

    Learning from the multiplayer interaction in sports, we describe our project TacTower; a flexible system for professional elite handball players to train game perception and kinesthetic em- pathy. The design is founded in ideas of Collective Interaction and qualities that is inherent in sport...

  16. Adiabatic Rearrangement of Hollow PV Towers

    Directory of Open Access Journals (Sweden)

    Eric A Hendricks

    2010-10-01

    Full Text Available Diabatic heating from deep moist convection in the hurricane eyewall produces a towering annular structure of elevated potential vorticity (PV. This structure has been referred to as a hollow PV tower. The sign reversal of the radial gradient of PV satisfies the Charney-Stern necessary condition for combined barotropic-baroclinic instability. For thin enough annular structures, small perturbations grow exponentially, extract energy from the mean flow, and lead to hollow tower breakdown, with significant vortex structural and intensity change. The three-dimensional adiabatic rearrangements of two prototypical hurricane-like hollow PV towers (one thick and one thin are examined in an idealized framework. For both hollow towers, dynamic instability causes air parcels with high PV to be mixed into the eye preferentially at lower levels, where unstable PV wave growth rates are the largest. Little or no mixing is found to occur at upper levels. The mixing at lower and middle levels is most rapid for the breakdown of the thin hollow tower, consistent with previous barotropic results. For both hollow towers, this advective rearrangement of PV affects the tropical cyclone structure and intensity in a number of ways. First, the minimum central pressure and maximum azimuthal mean velocity simultaneously decrease, consistent with previous barotropic results. Secondly, isosurfaces of absolute angular momentum preferentially shift inward at low levels, implying an adiabatic mechanism by which hurricane eyewall tilt can form. Thirdly, a PV bridge, similar to that previously found in full-physics hurricane simulations, develops as a result of mixing at the isentropic levels where unstable PV waves grow most rapidly. Finally, the balanced mass field resulting from the PV rearrangement is warmer in the eye between 900 and 700 hPa. The location of this warming is consistent with observed warm anomalies in the eye, indicating that in certain instances the hurricane

  17. Adaptive Backstepping Control of Lightweight Tower Wind Turbine

    DEFF Research Database (Denmark)

    Galeazzi, Roberto; Borup, Kasper Trolle; Niemann, Hans Henrik

    2015-01-01

    the angular deflection of the tower with respect to the vertical axis in response to variations in wind speed. The controller is shown to guarantee asymptotic tracking of the reference trajectory. The performance of the control system is evaluated through deterministic and stochastic simulations including......This paper investigates the feasibility of operating a wind turbine with lightweight tower in the full load region exploiting an adaptive nonlinear controller that allows the turbine to dynamically lean against the wind while maintaining nominal power output. The use of lightweight structures...... for towers and foundations would greatly reduce the construction cost of the wind turbine, however extra features ought be included in the control system architecture to avoid tower collapse. An adaptive backstepping collective pitch controller is proposed for tower point tracking control, i.e. to modify...

  18. Analysis of Ideal Towers for Tall Wind Applications: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Dykes, Katherine L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Damiani, Rick R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Roberts, Joseph O [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lantz, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-02-27

    Innovation in wind turbine tower design is of significant interest for future development of wind power plants. First, wind turbine towers account for a large portion of overall capital expenditures for wind power projects. Second, for low wind-resource regions of the world, the use of low-cost tall-tower technology has the potential to open new markets for development. This study investigates the relative potential of various tower configurations in terms of mass and cost. For different market applications and hub heights, idealized tall towers are designed and compared. The results show that innovation in wind turbine controls makes reaching higher hub heights with current technology economically viable. At the same time, new technologies hold promise for reducing tower costs as these technologies mature and hub heights reach twice the current average.

  19. Ejection Tower Lab

    Data.gov (United States)

    Federal Laboratory Consortium — The Ejection Tower Facility's mission is to test and evaluate new ejection seat technology being researched and developed for future defense forces. The captive and...

  20. Modeling of Direct Contact Wet Cooling Tower in ETRR-2

    International Nuclear Information System (INIS)

    El Khatib, H.H.; Ismail, A.L.; ElRefaie, M.E.

    2008-01-01

    The Egyptian Testing and Research Reactor no.2 (ETRR-2) was commissioned at 1997 with maximum power 22 MW for research purposes; an induced draft wet cooling tower (counter flow type) was putted in operation in 2003 instead of the first one. Investigations are achieved to evaluate cooling tower performance to guarantee that the cooling tower capable to dissipate heat generated in reactor core. Merkel and Poppe analysis was applied to simulate this cooling tower packing. Merkel analysis was applied to predict water outlet temperature from cooling tower and also to show the effect of ambient conditions on this temperature. Poppe analysis was applied to predict Merkel number which evaluate cooling tower. The Runge-Kutta numerical method was applied to solve the differential equations in this model and an engineering equation solver (EES) is the language used to model the cooling tower. This research illustrates that the cooling tower achieves good performance in various sever ambient condition at maximum operating condition of reactor power. The results show that at severe summer condition of wet bulb temperature equals 24 degree c and tower inlet temperature equals 37 degree c, the outlet water temperature equals 30.4 degree c from cooling tower, while the Merkel number is be found 1.253

  1. Structure of natural draft cooling towers, 1

    International Nuclear Information System (INIS)

    Ishioka, Hitoshi; Sakamoto, Yukichi; Tsurusaki, Mamoru; Koshizawa, Koichi; Chiba, Toshio

    1976-01-01

    Thousands of natural draft cooling towers have been utilized, in Europe and America, as cooling systems of power plants or as countermeasures against thermal polution. Recently in Japan, demands for cooling tower systems have been increasing remarkably with the construction of large power plants and the legislation of environmental regulations. In view of the severe natural conditions in Japan such as strong wind and seismic loadings, etc., the establishment of the optimum design and construction method is essential for the building of safe and economical towers. In order to establish a comprehensive plan of a power plant cooling system of the appropriate structural type, the authors have made researches and experiments on design conditions, static and dynamic analyses, and comparative studies of various structural types such as reinforced concrete thin-shell structures, steel framed structures and composite shell segment structures, based on the investigation results of towers in Europe and America. These results are presented in three reports, the 1st of which concerns cooling tower shells as are hereinafter described. (auth.)

  2. The shape of natural draft cooling towers

    International Nuclear Information System (INIS)

    Grange, J.L.

    1992-07-01

    The shape of cooling towers is more often designed empirically. There, it is considered from a theoretical point of view. The analysis of dynamic of natural draft and of the air flow in a cooling tower shell is presented. It is shown, that although it is convergent, a tower works like a diffuser for pressure recovery. And it is turbulence that produces a transfer of kinetic energy and allows a good operation of the diffusor. The equations permit to define a shell profile which depends upon the operating conditions of the cooling tower. In the same way, a stability criteria for natural draft depending upon operating conditions is established. A heating model of one meter diameter has been built in a thermal similitude. The turbulence rate has been measured with a hot wire anemometer at the tower exit and visualizations have also been made. Natural draft stability has been studied by these means for four different shell shapes and a wide range of operating conditions. Experimental and theoretical results agree satisfactorily and experiments can be considered as a validation of theory

  3. Engineering photochemical smog through convection towers

    Energy Technology Data Exchange (ETDEWEB)

    Elliott, S.; Prueitt, M.L.; Bossert, J.E.; Mroz, E.J.; Krakowski, R.A.; Miller, R.L. [Los Alamos National Lab., NM (United States); Jacobson, M.Z.; Turco, R.P. [Los Alamos National Lab., NM (United States)]|[Univ. of California, Los Angeles, CA (United States). Atmospheric Sciences Dept.

    1995-02-01

    Reverse convection towers have attracted attention as a medium for cleansing modern cities. Evaporation of an aqueous mist injected at the tower opening could generate electrical power by creating descent, and simultaneously scavenge unsightly and unhealthful particulates. The study offered here assesses the influence to tower water droplets on the photochemical component of Los Angeles type smog. The primary radical chain initiator OH is likely removed into aqueous phases well within the residence time of air in the tower, and then reacts away rapidly. Organics do not dissolve, but nighttime hydrolysis of N{sub 2}O{sub 5} depletes the nitrogen oxides. A lack of HOx would slow hydrocarbon oxidation and so also ozone production. Lowering of NOx would also alter ozone production rates, but the direction is uncertain. SO{sub 2} is available in sufficient quantities in some urban areas to react with stable oxidants, and if seawater were the source of the mist, the high pH would lead to fast sulfur oxidation kinetics. With an accommodation coefficient of 10{sup {minus}3}, however, ozone may not enter the aqueous phase efficiently. Even if ozone is destroyed or its production suppressed, photochemical recovery times are on the order of hours, so that tower processing must be centered on a narrow midday time window. The cost of building the number of structures necessary for this brief turnover could be prohibitive. The increase in humidity accompanying mist evaporation could be controlled with condensers, but might otherwise counteract visibility enhancements by recreating aqueous aerosols. Quantification of the divergent forcings convection towers must exert upon the cityscape would call for coupled three dimensional modeling of transport, microphysics, and photochemistry. 112 refs.

  4. Occupational exposure to radiofrequency fields in antenna towers

    International Nuclear Information System (INIS)

    Alanko, T.; Hietanen, M.

    2007-01-01

    Exposure of workers to radiofrequency fields was assessed in two medium-sized antenna towers. Towers had transmitting antennas from different networks, e.g. mobile phone networks, radio and digital TV sub-stations and amateur radio. The levels of radiofrequency fields were measured close to the ladders of the towers. All measured values were below ICNIRP occupational reference levels. (authors)

  5. Molten salt power towers operating at 600–650 °C: Salt selection and cost benefits

    Energy Technology Data Exchange (ETDEWEB)

    Turchi, Craig S. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Vidal, Judith [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bauer, Matthew

    2018-04-01

    This analysis examines the potential benefit of adopting the supercritical carbon dioxide (sCO2) Brayton cycle at 600-650 degrees C compared to the current state-of-the-art power tower operating a steam-Rankine cycle with solar salt at approximately 574 degrees C. The analysis compares a molten-salt power tower configuration using direct storage of solar salt (60:40 wt% sodium nitrate: potassium nitrate) or single-component nitrate salts at 600 degrees C or alternative carbonate- or chloride-based salts at 650 degrees C.

  6. Cooling tower water ozonation at Southern University

    International Nuclear Information System (INIS)

    Chen, C.C.; Knecht, A.T.; Trahan, D.B.; Yaghi, H.M.; Jackson, G.H.; Coppenger, G.D.

    1990-01-01

    Cooling-tower water is a critical utility for many industries. In the past, inexpensive water coupled with moderate regulation of discharge water led to the neglect of the cooling tower as an energy resource. Now, with the increased cost of chemical treatment and tough EPA rules and regulations, this situation is rapidly changing. The operator of the DOE Y-12 Plant in Oak Ridge as well as many other industries are forced to develop an alternate method of water treatment. The cooling tower is one of the major elements in large energy systems. The savings accrued from a well engineered cooling tower can be a significant part of the overall energy conservation plan. During a short-term ozonation study between 1987-1988, the Y-12 Plant has been successful in eliminating the need for cooling tower treatment chemicals. However, the long-term impact was not available. Since April 1988, the ozone cooling water treatment study at the Y-12 Plant has been moved to the site at Southern University in Baton Rouge, Louisiana. The purpose of this continued study is to determine whether the use of ozonation on cooling towers is practical from an economic, technical and environmental standpoint. This paper discusses system design, operating parameter and performance testing of the ozonation system at Southern University

  7. The new Drop Tower catapult system

    Science.gov (United States)

    von Kampen, Peter; Kaczmarczik, Ulrich; Rath, Hans J.

    2006-07-01

    The Center of Applied Space Technology and Microgravity (ZARM) was founded in 1985 as an institute of the University Bremen, which focuses on research on gravitational and space-related phenomena. In 1988, the construction of the "Drop Tower" began. Since then, the eye-catching tower with a height of 146 m and its characteristic glass roof has become the emblem of the technology centre in Bremen. The Drop Tower Bremen provides a facility for experiments under conditions of weightlessness. Items are considered weightless, when they are in "free fall", i.e. moving without propulsion within the gravity field of the earth. The height of the tower limits the simple "free fall" experiment period to max. 4.74 s. With the inauguration of the catapult system in December 2004, the ZARM is entering a new dimension. This world novelty will meet scientists' demands of extending the experiment period up to 9.5 s. Since turning the first sod on May 3rd, 1988, the later installation of the catapult system has been taken into account by building the necessary chamber under the tower. The catapult system is located in a chamber 10 m below the base of the tower. This chamber is almost completely occupied by 12 huge pressure tanks. These tanks are placed around the elongation of the vacuum chamber of the drop tube. In its centre there is the pneumatic piston that accelerates the drop capsule by the pressure difference between the vacuum inside the drop tube and the pressure inside the tanks. The acceleration level is adjusted by means of a servo hydraulic breaking system controlling the piston velocity. After only a quarter of a second the drop capsule achieves its lift-off speed of 175 km/h. With this exact speed, the capsule will rise up to the top of the tower and afterwards fall down again into the deceleration unit which has been moved under the drop tube in the meantime. The scientific advantages of the doubled experiment time are obvious: during almost 10 s of high

  8. Monitoring the performance of single and triple junction amorphous silicon modules in two building integrated photovoltaic (BIPV) installations

    International Nuclear Information System (INIS)

    Eke, Rustu; Senturk, Ali

    2013-01-01

    Highlights: • The first and the largest BIPV of Turkey were installed. • Single and triple junction amorphous module performances in BIPV applications are analyzed. • Total generated electricity of the BIPV system is measured as 103,702 kW h for 36 months of operation. • Annual energy rating is calculated as 856 kW h/kWp for a non-optimally oriented plant. • The PR of the system is found 0.74 and 0.81 for PV systems on towers and facade respectively. - Abstract: Mugla is located in south west Turkey at 37°13′N latitude and 28°36′E longitude with yearly sum of horizontal global irradiation exceeding 1700 kW h per square meter. Mugla has a Mediterranean Climate which is characterized by long, hot and dry summers with cool and wet winters. Mugla Sıtkı Kocman University is the largest “PV Park” in Turkey consisting of 100 kWp installed Photovoltaic Power Systems (PVPSs) with different PV applications. The 40 kWp building integrated photovoltaic (BIPV) system which is the first and largest in Turkey was installed on the façade and the two towers of the “Staff Block of the Education Faculty’s Building” of Mugla Sıtkı Kocman University in February 2008. Triple junction amorphous silicon photovoltaic modules are used on the façade and single junction amorphous silicon PV modules are used on the East and West towers of the building. In this paper, the 40 kWp BIPV system in Mugla, Turkey is presented, and its performance is evaluated. Energy rating (kW h/kWp energy yield), efficiencies and performance ratios of both applications are also evaluated for 36 months of operation. Daily, monthly and seasonal variations in performance parameters of the BIPV system in relation to solar data and meteorological parameters and outdoor performance of two reference modules (representing the modules on façade and towers) in a summer and a winter day are also investigated

  9. Cooling tower and environment

    International Nuclear Information System (INIS)

    Becker, J.; Ederhof, A.; Gosdowski, J.; Harms, A.; Ide, G.; Klotz, B.; Kowalczyk, R.; Necker, P.; Tesche, W.

    The influence of a cooling tower on the environment, or rather the influence of the environment on the cooling tower stands presently -along with the cooling water supply - in the middle of much discussion. The literature on these questions can hardly be overlooked by the experts concerned, especially not by the power station designers and operators. The document 'Cooling Tower and Environment' is intented to give a general idea of the important publications in this field, and to inform of the present state of technology. In this, the explanations on every section make it easier to get to know the specific subject area. In addition to older standard literature, this publication contains the best-known literature of recent years up to spring 1975, including some articles written in English. Further English literature has been collected by the ZAED (KFK) and is available at the VGB-Geschaefsstelle. Furthermore, The Bundesumweltamt compiles the literature on the subject of 'Environmental protection'. On top of that, further documentation centres are listed at the end of this text. (orig.) [de

  10. Frequency analysis of a tower-cable coupled system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Moo Yeol [Young Sin Precision Engineering Ltd., Gyungju (Korea, Republic of); Kim, Seock Hyun; Park, In Su [Kangwon National University, Chuncheon (Korea, Republic of); Cui, Chengxun [Yanbian University, Yangji (China)

    2013-06-15

    This study considers the prediction of natural frequency to avoid resonance in a wind turbine tower- cable coupled system. An analytical model based on the Rayleigh-Ritz method is proposed to predict the resonance frequency of a wind turbine tower structure supported by four guy cables. To verify the validity of the analytical model, a small tower-cable model is manufactured and tested. The frequency and mode data of the tower model are obtained by modal testing and finite element analysis. The validity of the proposed method is verified through the comparison of the frequency analysis results. Finally, using a parametric study with the analytical model, we identified how the cable tension and cable angle affect the resonance frequency of the wind turbine tower structure. From the analysis results, the tension limit and optimal angle of the cable are identified.

  11. Mobile Tower Radiation Protection System

    Directory of Open Access Journals (Sweden)

    Jabbar Slman Hussein

    2017-12-01

    Full Text Available Clean environment is one of the most necessarily needs for Human life. So what about mobile effect and its towers pollution? It's effect on public health? Effect of huge groan of mobile networks. In counting of these dangers that will harm us from mobile towers in the far run, was the reasons for writing this research, came this study to look at the mobile towers and mobile effects possible health harm for the purpose of diagnosis of these effects and to suggest ways that can be used to avoid or minimize the risks.  Faraday Cage, is the solution suggested here, also there are many other solutions for this problem, a Faraday cage is a metallic enclosure that stops the entry or escape of an EM field. Also, two experiments are accomplished, first one showing the effect of Faraday cage on preventing the EMR from mobile cellphone, and the second  experiment gives the effect of Faraday cage on preventing the EMR from mobile tower EMR on human health listed in the research, that have been done by using conducting shell (grid design according the EM wavelength used by three company's mobile working in Iraq, the result show good isolations.

  12. Cooling towers

    International Nuclear Information System (INIS)

    Boernke, F.

    1975-01-01

    The need for the use of cooling systems in power plant engineering is dealt with from the point of view of a non-polluting form of energy production. The various cooling system concepts up to the modern natural-draught cooling towers are illustrated by examples. (TK/AK) [de

  13. A modular interpretation of various cubic towers

    DEFF Research Database (Denmark)

    Anbar Meidl, Nurdagül; Bassa, Alp; Beelen, Peter

    2017-01-01

    In this article we give a Drinfeld modular interpretation for various towers of function fields meeting Zink's bound.......In this article we give a Drinfeld modular interpretation for various towers of function fields meeting Zink's bound....

  14. Cellular Phone Towers, Cell towers developed for Appraiser's Department in 2003. Location was based upon parcel centroids, and corrected to orthophotography. Probably includes towers other than cell towers (uncertain). Not published., Published in 2003, 1:1200 (1in=100ft) scale, Sedgwick County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Cellular Phone Towers dataset current as of 2003. Cell towers developed for Appraiser's Department in 2003. Location was based upon parcel centroids, and corrected...

  15. Evaluation of dynamic response for monopole and hybrid wind mill tower

    Science.gov (United States)

    Shah, Hemal J.; Desai, Atul K.

    2017-07-01

    The wind mill towers are constructed using monopoles or lattice type tower. As the height of tower increases it gives more power but it becomes uneconomical, so in the present research work innovative wind mill tower such as combination of monopole and lattice tower is analyzed using FEM software. When the tall structures are constructed on soft soil it becomes dynamically sensitive so 3 types of soil such as hard, medium and soft soil is also modeled and the innovative tower is studied for different operating frequencies of wind turbine. From study it is concluded that the innovative tower will reduce resonance condition considering soil structure interaction.

  16. Airline meteorological requirements

    Science.gov (United States)

    Chandler, C. L.; Pappas, J.

    1985-01-01

    A brief review of airline meteorological/flight planning is presented. The effects of variations in meteorological parameters upon flight and operational costs are reviewed. Flight path planning through the use of meteorological information is briefly discussed.

  17. Design and operation of hybrid cooling towers

    International Nuclear Information System (INIS)

    Alt, W.

    1987-01-01

    The first hybrid cooling tower at a coal-fired power station with a waste heat output of 550 MW has been in operation since the middle of 1985. Experience during the construction stage and the initial period of operation has confirmed the correctness of the design standards and of the design itself and, of course, also offers a wealth of knowledge to be observed on future construction projects. A second cooling tower of similar design is being erected at the present time. This cooling tower serves a power station unit with 2500 MW of waste heat output. The programme for this cooling tower offers the possibility for all the accumulated and evaluated experience to be of influence both on the design and also on the method of operation. This paper reports on the details. (orig.) [de

  18. Thermal performance of a transpired solar collector updraft tower

    International Nuclear Information System (INIS)

    Eryener, Dogan; Hollick, John; Kuscu, Hilmi

    2017-01-01

    Highlights: • Transpired solar collector updraft tower has been studied experimentally. • Transpired solar collector updraft tower efficiency ranges from 60 to 80%. • A comparison has been made with other SUT prototypes. • Three times higher efficiency compared to the glazed collectors of conventional solar towers. - Abstract: A novel solar updraft tower prototype, which consists of transpired solar collector, is studied, its function principle is described and its experimental thermal performance is presented for the first time. A test unit of transpired solar collector updraft tower was installed at the campus of Trakya University Engineering Faculty in Edirne-Turkey in 2014. Solar radiation, ambient temperature, collector cavity temperatures, and chimney velocities were monitored during summer and winter period. The results showed that transpired solar collector efficiency ranges from 60% to 80%. The maximum temperature rise in the collector area is found to be 16–18 °C on the typical sunny day. Compared to conventional solar tower glazed collectors, three times higher efficiency is obtained. With increased thermal efficiency, large solar collector areas for solar towers can be reduced in half or less.

  19. The Tower as a Metaphor and Concept

    DEFF Research Database (Denmark)

    Pihl, Ole Verner

    2007-01-01

     Abstract: The tower as an architectonic object is not only about scale, it is also about concept. In 1933, at the national showcase for the modernistic movement in Aalborg, Denmark the exhibition tower became a manifest and a landmark. The tower was inspired by the Russian constructivist Vladimir......: Gaming in a learning environment" that is an evaluation of the Sci-fi workshop seen from the outside.   Keywords: Tower, icon, experience design, interaction design, virtual and actual, past and future. ...

  20. Studies of column supported towers

    International Nuclear Information System (INIS)

    Chauvel, D.; Costaz, J.-L.

    1991-01-01

    As a result of a research and development programme into the civil engineering of cooling towers launched in 1978 by Electricite de France, very high cooling towers were built at Golfech and Chooz, in France, using column supports. This paper discusses the evolution of this new type of support from classical diagonal supports, presents some of the results of design calculations and survey measurements taken during construction of the shell and analyses the behaviour of the structure. (author)

  1. Engineering and economic evaluation of wet/dry cooling towers for water conservation

    International Nuclear Information System (INIS)

    Hu, M.C.

    1976-11-01

    The results are presented of a design and cost study for wet/dry tower systems used in conjunction with 1000 MWe nuclear power plants to reject waste heat while conserving water. Design and cost information for wet/dry tower systems are presented, and these cooling system alternatives are compared with wet and dry tower systems to determine whether the wet/dry tower concept is an economically viable alternative. The wet/dry cooling tower concept investigated is one which combines physically separated wet towers and dry towers into an operational unit. In designing the wet/dry tower, a dry cooling tower is sized to carry the plant heat load at low ambient temperatures, and a separate wet tower is added to augment the heat rejection of the dry tower at higher ambient temperatures. These wet/dry towers are designed to operate with a conventional low back pressure turbine commercially available today. The component wet and dry towers are state-of-the-art designs. From this study it was concluded that: wet/dry cooling systems can be designed to provide a significant economic advantage over dry cooling yet closely matching the dry tower's ability to conserve water, a wet/dry system which saves as much as 99 percent of the make-up water required by a wet tower can maintain that economic advantage, and therefore, for power plant sites where water is in short supply, wet/dry cooling is the economic choice over dry cooling

  2. Applied Meteorology Unit (AMU) Quarterly Report First Quarter FY-14

    Science.gov (United States)

    Bauman, William Henry; Crawford, Winifred C.; Shafer, Jaclyn A.; Watson, Leela R.; Huddleston, Lisa L.; Decker, Ryan K.

    2014-01-01

    NASA's LSP and other programs at Vandenberg Air Force Base (VAFB) use wind forecasts issued by the 30th Operational Support Squadron (30 OSS) to determine if they need to limit activities or protect property such as a launch vehicle due to the occurrence of warning level winds at VAFB in California. The 30 OSS tasked the AMU to provide a wind forecasting capability to improve wind warning forecasts and enhance the safety of their customers' operations. This would allow 30 OSS forecasters to evaluate pressure gradient thresholds between pairs of regional observing stations to help determine the onset and duration of warning category winds. Development of such a tool will require that solid relationships exist between wind speed and the pressure gradient of one or more station pairs. As part of this task, the AMU will also create a statistical climatology of meteorological observations from the VAFB wind towers.

  3. Numerical Simulation of Wind Turbine Blade-Tower Interaction

    Institute of Scientific and Technical Information of China (English)

    Qiang Wang; Hu Zhou; Decheng Wan

    2012-01-01

    Numerical simulations of wind turbine blade-tower interaction by using the open source OpenFOAM tools coupled with arbitrary mesh interface (AMI) method were presented.The governing equations were the unsteady Reynolds-averaged Navier-Stokes (PANS) which were solved by the pimpleDyMFoam solver,and the AMI method was employed to handle mesh movements.The National Renewable Energy Laboratory (NREL) phase Ⅵ wind turbine in upwind configuration was selected for numerical tests with different incoming wind speeds (5,10,15,and 25 m/s) at a fixed blade pitch and constant rotational speed.Detailed numerical results of vortex structure,time histories of thrust,and pressure distribution on the blade and tower were presented.The findings show that the wind turbine tower has little effect on the whole aerodynamic performance of an upwind wind turbine,while the rotating rotor will induce an obvious cyclic drop in the front pressure of the tower.Also,strong interaction of blade tip vortices with separation from the tower was observed.

  4. 40 CFR 63.1329 - Process contact cooling towers provisions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 11 2010-07-01 2010-07-01 true Process contact cooling towers... Process contact cooling towers provisions. (a) The owner or operator of each new affected source that... end finisher process that utilizes a process contact cooling tower shall comply with paragraph (c) of...

  5. Optimization of steel monopod offshore-towers under probabilistic constraints

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.

    2008-01-01

    In this work, economical design implementation of a circular steel monopod-offshore-tower, which is subjected to the extreme wave loading, is presented. The mass of the tower is considered as the objective function. The thickness and radius of the cross-section of the tower are adopted as design

  6. The design and stability determination of wind turbine tower

    International Nuclear Information System (INIS)

    Abas Abd Wahab; Khairul Barriyah

    2001-01-01

    In wind turbine tower design, two load categories (static and wind load) were considered. The static load for this structure is the tower self-weight, which can be calculated from its density and area of the material, whereas the wind load was calculated based on CP3: Chapter V: Part 2: 1972, using the maximum wind speed of 30 m/s. The stability of this tower under the action of these two loads has been determined using RISA-3D program. The program were subjected to two joint types, i.e pinned and fixed joints. The tower using fixed joint members has established the necessary tower stability. The simulation, calculation and results are being discussed in detail in this paper. (Author)

  7. The Drop Tower Bremen -Experiment Operation

    Science.gov (United States)

    Könemann, Thorben; von Kampen, Peter; Rath, Hans J.

    The idea behind the drop tower facility of the Center of Applied Space Technology and Micro-gravity (ZARM) in Bremen is to provide an inimitable technical opportunity of a daily access to short-term weightlessness on earth. In this way ZARM`s european unique ground-based microgravity laboratory displays an excellent economic alternative for research in space-related conditions at low costs comparable to orbital platforms. Many national and international ex-perimentalists motivated by these prospects decide to benefit from the high-quality and easy accessible microgravity environment only provided by the Drop Tower Bremen. Corresponding experiments in reduced gravity could open new perspectives of investigation methods and give scientists an impressive potential for a future technology and multidisciplinary applications on different research fields like Fundamental Physics, Astrophysics, Fluid Dynamics, Combus-tion, Material Science, Chemistry and Biology. Generally, realizing microgravity experiments at ZARM`s drop tower facility meet new requirements of the experimental hardware and may lead to some technical constraints in the setups. In any case the ZARM Drop Tower Operation and Service Company (ZARM FAB mbH) maintaining the drop tower facility is prepared to as-sist experimentalists by offering own air-conditioned laboratories, clean rooms, workshops and consulting engineers, as well as scientific personal. Furthermore, ZARM`s on-site apartment can be used for accommodations during the experiment campaigns. In terms of approaching drop tower experimenting, consulting of experimentalists is mandatory to successfully accomplish the pursued drop or catapult capsule experiment. For this purpose there will be a lot of expertise and help given by ZARM FAB mbH in strong cooperation to-gether with the experimentalists. However, in comparison to standard laboratory setups the drop or catapult capsule setup seems to be completely different at first view. While defining a

  8. Noise emissions of cooling towers; Geraeuschemissionen von Kuehltuermen

    Energy Technology Data Exchange (ETDEWEB)

    Hinkelmann, Dirk [Mueller-BBM GmbH, Gelsenkirchen (Germany)

    2013-09-01

    Cooling towers are often large structures with high sound emission. The impact of water drops on the water surface in the collecting basin leads to the generation of middle- and high-frequency noise that is emitted via the air intake opening and the outlet. In forced-draft cooling towers, additional noise is generated by drives and fans. The sound emissions can be predicted by means of empirical calculation models. In this way, noise control measures can be taken into account already at an early phase of planning. Different, proven measures for reduction of sound emissions are taken depending on cooling tower design. Regulations on noise acceptance testing for cooling towers are given in various standards. (orig.)

  9. Main photoautotrophic components of biofilms in natural draft cooling towers.

    Science.gov (United States)

    Hauer, Tomáš; Čapek, Petr; Böhmová, Petra

    2016-05-01

    While photoautotrophic organisms are an important component of biofilms that live in certain regions of natural draft cooling towers, little is known about these communities. We therefore examined 18 towers at nine sites to identify the general patterns of community assembly in three distinct tower parts, and we examined how community structures differ depending on geography. We also compared the newly acquired data with previously published data. The bottom sections of draft cooling towers are mainly settled by large filamentous algae, primarily Cladophora glomerata. The central portions of towers host a small amount of planktic algae biomass originating in the cooling water. The upper fourths of towers are colonized by biofilms primarily dominated by cyanobacteria, e.g., members of the genera Gloeocapsa and Scytonema. A total of 41 taxa of phototrophic microorganisms were identified. Species composition of the upper fourth of all towers was significantly affected by cardinal position. There was different species composition at positions facing north compared to positions facing south. West- and east-facing positions were transitory and highly similar to each other in terms of species composition. Biofilms contribute to the degradation of paint coatings inside towers.

  10. Providing Meteorological Information for Controlled Burns at the Savannah River Site

    International Nuclear Information System (INIS)

    Buckley, R.

    1999-01-01

    Regional and local weather information are important for a variety of applications at the Savannah River Site (SRS), a Department of Energy (DOE) facility covering approximately 800 square kilometers of southwest South Carolina east of the Savannah River. For example, meteorological observations and forecasts are used to assess the consequences of an accidental radiological or chemical release. Traditionally, hazards posed by SRS operations have been associated with nuclear reactors, chemical reprocessing plants, fuel fabrication, or waste-vitrification facilities. However, recent events have shown site-specific meteorology to be a valuable tool to the United States Forest Service (USFS) in mitigating potential hazards from controlled burns that are conducted at the SRS. Prescribed burns at the SRS are important for a variety of reasons. The removal of thick undergrowth allows wildlife to more easily feed and migrate, accelerates the growth of young pine stands, and controls certain diseases that affect local pine forests (e.g. Adams et al. 1973). In addition, the removal of twigs, pine needles, or leaves (a fuel source) reduces the chance of serious wildfire damage. However, the threat of smoke inhalation and reduced visibility requires careful planning on the part of the fire professionals. At the SRS, approximately 100 square kilometers of land per year are burned in a controlled manner, mainly in the spring.To reduce the potentially harmful effects to any onsite activity, it is important that USFS personnel understand current and predicted weather patterns within the area. This paper discusses two sources of meteorological information that are provided to SRS-USFS personnel for use in planning forest burns: (1) a meteorological tower system which provides current data from a series of onsite locations, and (2) an operational prognostic mesoscale model used to generate forecast information. The forecast data supplements the basic National Weather Service (NWS

  11. Round Earthen Towers in Zhangzhou

    Institute of Scientific and Technical Information of China (English)

    1992-01-01

    The round earthen towers inZhangzhou,Fujifan Province,have long been famous a-round the world.Built of rammedearth,each tower consists uf four tofive stories and Is nearly 100 metersin diameter and 17 to 18meters high.Scatteredaround the mountains,valleys and plains insouthwestern Fujian,thetowers look very muchlike round castles.SomeChinese and foreign ar-chitercts,historians andfolk-custom researcherscall them“flyng sau-cers”from outer spaceor“mushrooms”fromearth.They represent,indeed,a unique archi-tectural style in theworld.

  12. Dynamic analysis of cooling towers

    International Nuclear Information System (INIS)

    Bittnar, Z.

    1987-01-01

    Natural draught cooling towers are shell structures subjected to random vibrations due to wind turbulence and earthquake. The need of big power plant units has initiated the design of very large cooling towers. The random response of such structures may be analysed using a spectral approach and assuming a linear behaviour of the structure. As the modal superposition method is the most suitable procedure for this purpose it is necessary to determine the natural frequencies and mode shapes with adequate accuracy. (orig./GL)

  13. Cooling towers: a bibliography

    International Nuclear Information System (INIS)

    Whitson, M.O.

    1981-02-01

    This bibliography cites 300 selected references containing information on various aspects of large cooling tower technology, including design, construction, operation, performance, economics, and environmental effects. The towers considered include natural-draft and mechanical-draft types employing wet, dry, or combination wet-dry cooling. A few references deal with alternative cooling methods, principally ponds or spray canals. The citations were compiled for the DOE Energy Information Data Base (EDB) covering the period January to December 1980. The references are to reports from the Department of Energy and its contractors, reports from other government or private organizations, and journal articles, books, conference papers, and monographs from US originators

  14. Tall towers for large wind turbines. Report from Vindforsk project V-342

    Energy Technology Data Exchange (ETDEWEB)

    Engstroem, Staffan; Lyrner, Tomas; Hassanzadeh, Manouchehr; Stalin, Thomas; Johansson, John

    2010-07-15

    The general rule of thumb has been to furnish a wind turbine with a tower as tall as the turbine diameter, with deviations downwards for high wind speed sites. In this report the statement is questioned, with special emphasis for wind turbines sited in forests. The aim of this project was to propose and calculate candidate types of tall towers for on-shore wind turbines in the 3 - 5 MW range, with special reference to siting in forests with a representative wind shear. During the project this scope has been more precisely defined to study 3 and 5 MW wind turbines with hub heights of 80 - 175 meters featuring the following tower solutions: 1. Steel shell tower designed in a conventional way with flanges and both longitudinal and transverse welds. 2. Steel shell tower with bolted friction joints only. 3. Concrete tower with pretensioned steel tendons. 4. Hybrid tower with a lower concrete part and an upper part built as a conventional steel shell. 5. Lattice tower. 6. Wooden tower. During the execution of the project the design of a total of 42 towers was outlined and calculated. Today the welded steel shell tower dominates the wind turbine market. Larger turbines and higher hub heights result in larger optimal tower base diameters. For the road transportation there are limitations due to bridges and other obstacles. In Sweden the limit for transports with special permits in general maximizes the diameter to 4,5 metres. To some extent it is still technically possible to build towers with a less than optimal diameter, but due to the high mass and the large wall thickness they tend to be uneconomical in comparison with other alternatives above a hub height of roughly 100 metres. In this report welded steel shell towers were outlined for 3 MW turbines up to a hub height of 150 metres whereas the limit for the 5 MW towers was 100 metres. When diameter restrictions tend to make welded towers uneconomical, the next logical choice is steel shell towers with bolted friction

  15. The Design of Akhmat Tower

    Directory of Open Access Journals (Sweden)

    Beardsley Sara

    2018-01-01

    Full Text Available Akhmat Tower is a 435m supertall building designed by Adrian Smith + Gordon Gill Architecture. It is currently under construction in the city of Grozny, in the Chechen Republic, in the North Caucasus region of Russia. The design of the tower was done during a collaborative process by a multi-disciplinary architectural and engineering team, based primarily in the United States and Russia. During this process, the designers considered many factors including, most primarily, the cultural and historical context, the structural requirements given the high seismicity of the region, and the client’s programmatic needs. The resulting crystalline-shaped tower is both an aesthetic statement and a performative architectural solution which will be a new landmark for Chechnya. “The Design of Akhmat Tower” describes in detail the design process including structural considerations, exterior wall design, building program, interior design, the tuned mass damper, and the use of building information modeling.

  16. Motivational Meteorology.

    Science.gov (United States)

    Benjamin, Lee

    1993-01-01

    Describes an introductory meteorology course for nonacademic high school students. The course is made hands-on by the use of an educational software program offered by Accu-Weather. The program contains a meteorology database and instructional modules. (PR)

  17. Piers cooling towers. From first idess to realizations

    International Nuclear Information System (INIS)

    Bozetto, P.; Tzincoca, A.

    1988-01-01

    After a first part consecrated at the historical aspect of vertical piers cooling towers the second part indicates the experience pulled of the Chooz and Golfech cooling towers conception and realization [fr

  18. On the prospects for dry cooling tower building in FRG

    International Nuclear Information System (INIS)

    Dzhurinskij, M.B.; Zlotin, A.A.

    1982-01-01

    Advantages and disadvantages of dry cooling towers for NPPs are considered. Construction of a number of cooling towers in FRY are described. The advisability of building cooling towers of a combined type - with wet aud dry sections is noted

  19. A study of the life expectancy of cooling towers

    International Nuclear Information System (INIS)

    Bolvin, M.; Chauvel, D.

    1993-01-01

    The paper describes the following different tasks of the study whose aim was to extend the life time of cooling towers for French Nuclear Power plants to 40 years. The aging factors specific to cooling towers were measured and analysed with regard to the external surface, the internal surface and inside the concrete. The safety coefficient for buckling was calculated and then the stress analysis of the materials (concrete and steel) was done. A special computer program written for cooling towers was used with a model including the soil stiffness and the supports of the tower. (author)

  20. European sail tower SPS [Solar Power Satellite] concept

    Energy Technology Data Exchange (ETDEWEB)

    Seboldt, W.; Leipold, M.; Hanowski, N. [Institute of Space Sensor Technology and Planetary Exploration, Cologne (Germany). German Aerospace Center; Klimke, M. [HOPE Worldwide Deutschland, Berlin (Germany)

    2001-06-01

    Based on a DLR-study in 1998/99 on behalf of ESA/ESTEC called ''System Concepts, Architectures and Technologies for Space Exploration and Utilization (SE and U)'' a new design for an Earth-orbiting Solar Power Satellite (SPS) has been developed. The design is called ''European Sail Tower SPS'' and consists mainly of deplorable sail-like structures derived from the ongoing DLR/ESA solar sail technology development activity. Such an SPS satellite features an extremely light-weight and large tower-like orbital system and could supply Europe with significant amounts of electrical power generated by photovoltaic cells and subsequently transmitted to earth via microwaves. In order to build up the sail tower, 60 units - each consisting of a pair of square-shaped sails - are moved from LEO to GEO with electric propulsion and successively assembled in GEO robotically on a central strut. Each single sail has dimensions of 150 m x 150 m and is automatically deployed, using four diagonal lightweight carbon fiber (CFRP) booms which are initially rolled up on a central hub. The electric thrusters for the transport to GEO could also be used for orbit and attitude control of the assembled tower which has a total length of about 15 km and would be mainly gravity gradient stabilized. Employing thin film solar cell technology, each sail is used as a solar array and produces an electric power in orbit of about 3.7 MW{sub e}. A microwave antenna with a diameter of 1 km transmits the power to a 10 km rectenna on the ground. The total mass of this 450 MW SPS is about 2100 tons. First estimates indicate that the costs for one kWh delivered in this way could compete with present day energy costs, if launch costs would decrease by two orders of magnitude. Furthermore, mass production and large numbers of installed SPS systems must be assumed in order to lower significantly the production costs and to reduce the influence of the expensive technology

  1. Aerosol Optical Properties Derived from the DRAGON-NE Asia Campaign, and Implications for a Single-Channel Algorithm to Retrieve Aerosol Optical Depth in Spring from Meteorological Imager (MI) On-Board the Communication, Ocean, and Meteorological Satellite (COMS)

    Science.gov (United States)

    Kim, M.; Kim, J.; Jeong, U.; Kim, W.; Hong, H.; Holben, B.; Eck, T. F.; Lim, J.; Song, C.; Lee, S.; hide

    2016-01-01

    An aerosol model optimized for northeast Asia is updated with the inversion data from the Distributed Regional Aerosol Gridded Observation Networks (DRAGON)-northeast (NE) Asia campaign which was conducted during spring from March to May 2012. This updated aerosol model was then applied to a single visible channel algorithm to retrieve aerosol optical depth (AOD) from a Meteorological Imager (MI) on-board the geostationary meteorological satellite, Communication, Ocean, and Meteorological Satellite (COMS). This model plays an important role in retrieving accurate AOD from a single visible channel measurement. For the single-channel retrieval, sensitivity tests showed that perturbations by 4 % (0.926 +/- 0.04) in the assumed single scattering albedo (SSA) can result in the retrieval error in AOD by over 20 %. Since the measured reflectance at the top of the atmosphere depends on both AOD and SSA, the overestimation of assumed SSA in the aerosol model leads to an underestimation of AOD. Based on the AErosol RObotic NETwork (AERONET) inversion data sets obtained over East Asia before 2011, seasonally analyzed aerosol optical properties (AOPs) were categorized by SSAs at 675 nm of 0.92 +/- 0.035 for spring (March, April, and May). After the DRAGON-NE Asia campaign in 2012, the SSA during spring showed a slight increase to 0.93 +/- 0.035. In terms of the volume size distribution, the mode radius of coarse particles was increased from 2.08 +/- 0.40 to 2.14 +/- 0.40. While the original aerosol model consists of volume size distribution and refractive indices obtained before 2011, the new model is constructed by using a total data set after the DRAGON-NE Asia campaign. The large volume of data in high spatial resolution from this intensive campaign can be used to improve the representative aerosol model for East Asia. Accordingly, the new AOD data sets retrieved from a single-channel algorithm, which uses a precalculated look-up table (LUT) with the new aerosol model, show

  2. Meteorological satellite systems

    CERN Document Server

    Tan, Su-Yin

    2014-01-01

    Meteorological Satellite Systems” is a primer on weather satellites and their Earth applications. This book reviews historic developments and recent technological advancements in GEO and polar orbiting meteorological satellites. It explores the evolution of these remote sensing technologies and their capabilities to monitor short- and long-term changes in weather patterns in response to climate change. Satellites developed by various countries, such as U.S. meteorological satellites, EUMETSAT, and Russian, Chinese, Japanese and Indian satellite platforms are reviewed. This book also discusses international efforts to coordinate meteorological remote sensing data collection and sharing. This title provides a ready and quick reference for information about meteorological satellites. It serves as a useful tool for a broad audience that includes students, academics, private consultants, engineers, scientists, and teachers.

  3. Wind Power Meteorology

    DEFF Research Database (Denmark)

    Lundtang Petersen, Erik; Mortensen, Niels Gylling; Landberg, Lars

    Wind power meteorology has evolved as an applied science, firmly founded on boundary-layer meteorology, but with strong links to climatology and geography. It concerns itself with three main areas: siting of wind turbines, regional wind resource assessment, and short-term prediction of the wind...... resource. The history, status and perspectives of wind power meteorology are presented, with emphasis on physical considerations and on its practical application. Following a global view of the wind resource, the elements of boundary layer meteorology which are most important for wind energy are reviewed......: wind profiles and shear, turbulence and gust, and extreme winds. The data used in wind power meteorology stem mainly from three sources: onsite wind measurements, the synoptic networks, and the re-analysis projects. Wind climate analysis, wind resource estimation and siting further require a detailed...

  4. Cell-Phone Tower Power System Prototype Testing for Verizon Wireless |

    Science.gov (United States)

    Advanced Manufacturing Research | NREL Cell-Phone Tower Power System Prototype Testing for Verizon Wireless Cell-Phone Tower Power System Prototype Testing for Verizon Wireless For Verizon Wireless , NREL tested a new cell-phone tower power system prototype based on DC interconnection and photovoltaics

  5. TacTower

    DEFF Research Database (Denmark)

    Rasmussen, Majken Kirkegaard; Jürgensen, Christine

    2009-01-01

    Learning from the multiplayer interaction in sports, we describe our project TacTower; a flexible system for professional elite handball players to train game perception and kinesthetic em- pathy. The design is founded in ideas of Collective Interaction and qualities that is inherent in sport...... and is based on consid- erations about paralanguage, kinesthetic emphatic interaction, physical positioning of players and collaborative interaction....

  6. Meteorological radar services: a brief discussion and a solution in practice

    Science.gov (United States)

    Nicolaides, K. A.

    2014-08-01

    The Department of Meteorology is the organization designated by the Civil Aviation Department and by the National Supervisory Authority of the Republic of Cyprus, as an air navigation service provider, based on the regulations of the Single European Sky. Department of Meteorology holds and maintains also an ISO: 9001/2008, Quality System, for the provision of meteorological and climatological services to aeronautic and maritime community, but also to the general public. In order to fulfill its obligations the Department of Meteorology customs the rather dense meteorological stations network, with long historical data series, installed and maintained by the Department, in parallel with modelling and Numerical Weather Prediction (NWP), along with training and gaining of expertise. Among the available instruments in the community of meteorologists is the meteorological radar, a basic tool for the needs of very short/short range forecasting (nowcasting). The Department of Meteorology installed in the mid 90's a C-band radar over «Throni» location and expanded its horizons in nowcasting, aviation safety and warnings issuance. The radar has undergone several upgrades but today technology has over passed its rather old technology. At the present the Department of Meteorology is in the process of buying Meteorological Radar Services as a result of a public procurement procedure. Two networked X-band meteorological radar will be installed (the project now is in the phase of infrastructure establishment while the hardware is in the process of assemble), and maintained from Space Hellas (the contractor) for a 13 years' time period. The present article must be faced as a review article of the efforts of the Department of Meteorology to support its weather forecasters with data from meteorological radar.

  7. Comparison of sap flux, moisture flux tower and MODIS enhanced vegetation index methods for estimating riparian evapotranspiration

    Science.gov (United States)

    Nagler, Pamela L.; Glenn, Edward P.; Morino, Kiyomi; Neale, Christopher M.U; Cosh, Michael H.

    2010-01-01

    Riparian evapotranspiration (ET) was measured on a salt cedar (Tamarix spp.) dominated river terrace on the Lower Colorado River from 2007 to 2009 using tissue-heat-balance sap flux sensors at six sites representing very dense, medium dense, and sparse stands of plants. Salt cedar ET varied markedly across sites, and sap flux sensors showed that plants were subject to various degrees of stress, detected as mid-day depression of transpiration and stomatal conductance. Sap flux results were scaled from the leaf level of measurement to the stand level by measuring plant-specific leaf area index and fractional ground cover at each site. Results were compared to Bowen ratio moisture tower data available for three of the sites. Sap flux sensors and flux tower results ranked the sites the same and had similar estimates of ET. A regression equation, relating measured ET of salt cedar and other riparian plants and crops on the Lower Colorado River to the Enhanced Vegetation Index from the MODIS sensor on the Terra satellite and reference crop ET measured at meteorological stations, was able to predict actual ET with an accuracy or uncertainty of about 20%, despite between-site differences for salt cedar. Peak summer salt cedar ET averaged about 6 mm d-1 across sites and methods of measurement.

  8. The Damaging Effects of Earthquake Excitation on Concrete Cooling Towers

    International Nuclear Information System (INIS)

    Abedi-Nik, Farhad; Sabouri-Ghomi, Saeid

    2008-01-01

    Reinforced concrete cooling towers of hyperbolic shell configuration find widespread application in utilities engaged in the production of electric power. In design of critical civil infrastructure of this type, it is imperative to consider all the possible loading conditions that the cooling tower may experience, an important loading condition in many countries is that of the earthquake excitation, whose influence on the integrity and stability of cooling towers is profound. Previous researches have shown that the columns supporting a cooling tower are sensitive to earthquake forces, as they are heavily loaded elements that do not possess high ductility, and understanding the behavior of columns under earthquake excitation is vital in structural design because they provide the load path for the self weight of the tower shell. This paper presents the results of a finite element investigation of a representative 'dry' cooling tower, using realistic horizontal and vertical acceleration data obtained from the recent and widely-reported Tabas, Naghan and Bam earthquakes in Iran. The results of both linear and nonlinear analyses are reported in the paper, the locations of plastic hinges within the supporting columns are identified and the ramifications of the plastic hinges on the stability of the cooling tower are assessed. It is concluded that for the (typical) cooling tower configuration analyzed, the columns that are instrumental in providing a load path are influenced greatly by earthquake loading, and for the earthquake data used in this study the representative cooling tower would be rendered unstable and would collapse under the earthquake forces considered

  9. The Worlds First Ever Cooling Tower Acceptance Test Using Process Data Reconciliation

    International Nuclear Information System (INIS)

    Magnus Langenstein; Jan Hansen-Schmidt

    2006-01-01

    The cooling capacity of cooling towers is influenced by multiple constructive and atmospheric parameters in a very complex way. This leads to strong variations of the measured cold-water temperature and causes unacceptable unreliability of conventional acceptance tests, which are based on single point measurements. In order to overcome this lack of accuracy a new approach to acceptance test based on process data reconciliation has been developed by BTB Jansky and applied at a nuclear power plant. This approach uses process data reconciliation according to VDI 2048 to evaluate datasets over a long period covering different operating conditions of the cooling tower. Data reconciliation is a statistical method to determine the true process parameters with a statistical probability of 95% by considering closed material-, mass-and energy balances. Datasets which are not suitable for the evaluation due to strong transient gradients are excluded beforehand, according to well-defined criteria. The reconciled cold-water temperature is then compared, within a wet bulb temperature range of 5 deg. C to 20 deg. C to the manufacturer's guaranteed temperature. Finally, if the average deviation between reconciled and guaranteed value over the evaluated period is below zero, the cooling tower guarantee is fulfilled. (authors)

  10. Tridimensional statistic analysis of cooling tower plumes. Methods and results relating to power effect and disposal conditions

    International Nuclear Information System (INIS)

    Sabaton, M.; Viollet, P.L.; Darles, A.; Gland, H.

    1980-07-01

    The PANACH three dimensional calculation code developed from tests on a small scale model and validated from full scale measurement campaigns, was used to estimate a three dimensional statistic of plumes. As it is not possible with the calculation times to make a calculation for each radio sondage, a classification method was adopted. This method developed by the French National Meteorological Office is based on a double classification comprising basic classes in which the plumes are assumed to be dynamically similar and a sub-classification to take better account of the true moisture profiles. This statistical method was then applied to the case of 2 or 4 1300 MWe units fitted with natural draught cooling towers of the wet, dry or wet-dry types [fr

  11. Overall Analysis of Meteorological Information in the KAERI Site (2006 Annual Report)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, E. H.; Choi, G. S.; Choi, S. D

    2007-07-15

    Inspection and repair of tower structure and lift, instrument calibration have been done in the scope of 'Environmental Radiation Monitoring Around the Nuclear Facilities' project. Wind direction, wind speed, temperature, humidity at 67m, 27m, and 10m height and temperature, humidity, atmospheric pressure, solar radiation, precipitation, and visibility at surface have been measured and analyzed with statistical methods. At the site, the prevailing wind directions were N in winter, SW in 2nd, E in 3rd quaters. The calm distributed 14.7% at 67m, 33.2% at 27m, 57.3% at 10m height. Wireless data transmission to MIPS(Meteorological Information Processing System) has been done after collection in the DAS where environmental assessment can be done by the developed simulation programs in both cases of normal operation and emergency.

  12. Legionella confirmation in cooling tower water

    Science.gov (United States)

    Farhat, Maha; Shaheed, Raja A.; Al-Ali, Haidar H.; Al-Ghamdi, Abdullah S.; Al-Hamaqi, Ghadeer M.; Maan, Hawraa S.; Al-Mahfoodh, Zainab A.; Al-Seba, Hussain Z.

    2018-01-01

    Objectives: To investigate the presence of Legionella spp in cooling tower water. Legionella proliferation in cooling tower water has serious public health implications as it can be transmitted to humans via aerosols and cause Legionnaires’ disease. Methods: Samples of cooling tower water were collected from King Fahd Hospital of the University (KFHU) (Imam Abdulrahman Bin Faisal University, 2015/2016). The water samples were analyzed by a standard Legionella culture method, real-time polymerase chain reaction (RT-PCR), and 16S rRNA next-generation sequencing. In addition, the bacterial community composition was evaluated. Results: All samples were negative by conventional Legionella culture. In contrast, all water samples yielded positive results by real-time PCR (105 to 106 GU/L). The results of 16S rRNA next generation sequencing showed high similarity and reproducibility among the water samples. The majority of sequences were Alpha-, Beta-, and Gamma-proteobacteria, and Legionella was the predominant genus. The hydrogen-oxidizing gram-negative bacterium Hydrogenophaga was present at high abundance, indicating high metabolic activity. Sphingopyxis, which is known for its resistance to antimicrobials and as a pioneer in biofilm formation, was also detected. Conclusion: Our findings indicate that monitoring of Legionella in cooling tower water would be enhanced by use of both conventional culturing and molecular methods. PMID:29436561

  13. Tower-Top Antenna Array Calibration Scheme for Next Generation Networks

    Directory of Open Access Journals (Sweden)

    McCormack Justine

    2007-01-01

    Full Text Available Recently, there has been increased interest in moving the RF electronics in basestations from the bottom of the tower to the top, yielding improved power efficiencies and reductions in infrastructural costs. Tower-top systems have faced resistance in the past due to such issues as increased weight, size, and poor potential reliability. However, modern advances in reducing the size and complexity of RF subsystems have made the tower-top model more viable. Tower-top relocation, however, faces many significant engineering challenges. Two such challenges are the calibration of the tower-top array and ensuring adequate reliability. We present a tower-top smart antenna calibration scheme designed for high-reliability tower-top operation. Our calibration scheme is based upon an array of coupled reference elements which sense the array's output. We outline the theoretical limits of the accuracy of this calibration, using simple feedback-based calibration algorithms, and present their predicted performance based on initial prototyping of a precision coupler circuit for a array. As the basis for future study a more sophisticated algorithm for array calibration is also presented whose performance improves with array size.

  14. Vibration analysis of three guyed tower designs for intermediate size wind turbines

    Science.gov (United States)

    Christie, R. J.

    1982-01-01

    Three guyed tower designs were analyzed for intermediate size wind turbines. The four lowest natural frequencies of vibration of the three towers concepts were estimated. A parametric study was performed on each tower to determine the effect of varying such tower properties as the inertia and stiffness of the tower and guys, the inertia values of the nacelle and rotor, and the rotational speed of the rotor. Only the two lowest frequencies were in a range where they could be excited by the rotor blade passing frequencies. There two frequencies could be tuned by varying the guy stiffness, the guy attachment point on the tower, the tower and mass stiffness, and the nacelle/rotor/power train masses.

  15. Numerical research of a super-large cooling tower subjected to accidental loads

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yi; Lin, Feng [Department of Building Engineering, Tongji University, Shanghai 200092 (China); Gu, Xianglin, E-mail: gxl@tongji.edu.cn [Department of Building Engineering, Tongji University, Shanghai 200092 (China); Lu, Xiaoqin [Guangdong Electric Power Design Institute, Guangzhou 510660 (China)

    2014-04-01

    With the continued development of nuclear power plants, more and more super-large cooling towers are to be built in China and around the world. For the safe operation of nuclear power plants, research work has been done on the causes of collapse of cooling towers, collapse modes and the secondary disasters caused by the collapse of cooling towers. However, the collapse modes and the ground vibration induced by the collapse of cooling towers subjected to the accidental loads have not been fully understood. This paper has been focused on the modes and mechanisms behavior of the collapse of cooling towers subjected to accidental loads. Meanwhile, prediction of the ground vibration due to the collapse of the cooling towers has also been completed in a parallel project. Using dynamic finite element program LS-DYNA, a 3D finite element model for a super-large cooling tower was developed and the nonlinear material models were incorporated. In this paper, four types of accidental loads were considered to trigger the collapse or local failure of the tower, including vehicle collision, airplane impact, local explosion and missile attack. It was found that vehicle collision, missile attack and small TNT equivalent explosives (2 kg, 20 kg, 200 kg) might result in local failure of the cooling tower, however, the tower can still keep stable. On the other hand, large TNT equivalent explosives (2000 kg, 4500 kg) could cause severe damages in the inclined columns of the cooling tower, and lead to progressive collapse of the entire cooling tower. The two kinds of TNT equivalent explosives caused the same collapse mode while the collapsing duration was different. The airplane impacted at the throat of the cooling tower caused the local failure of shell structure of the tower, and then the progressive collapse of the cooling tower happened due to the gravitational action. The resulting collapse mode was different from that triggered by the local explosion.

  16. Numerical research of a super-large cooling tower subjected to accidental loads

    International Nuclear Information System (INIS)

    Li, Yi; Lin, Feng; Gu, Xianglin; Lu, Xiaoqin

    2014-01-01

    With the continued development of nuclear power plants, more and more super-large cooling towers are to be built in China and around the world. For the safe operation of nuclear power plants, research work has been done on the causes of collapse of cooling towers, collapse modes and the secondary disasters caused by the collapse of cooling towers. However, the collapse modes and the ground vibration induced by the collapse of cooling towers subjected to the accidental loads have not been fully understood. This paper has been focused on the modes and mechanisms behavior of the collapse of cooling towers subjected to accidental loads. Meanwhile, prediction of the ground vibration due to the collapse of the cooling towers has also been completed in a parallel project. Using dynamic finite element program LS-DYNA, a 3D finite element model for a super-large cooling tower was developed and the nonlinear material models were incorporated. In this paper, four types of accidental loads were considered to trigger the collapse or local failure of the tower, including vehicle collision, airplane impact, local explosion and missile attack. It was found that vehicle collision, missile attack and small TNT equivalent explosives (2 kg, 20 kg, 200 kg) might result in local failure of the cooling tower, however, the tower can still keep stable. On the other hand, large TNT equivalent explosives (2000 kg, 4500 kg) could cause severe damages in the inclined columns of the cooling tower, and lead to progressive collapse of the entire cooling tower. The two kinds of TNT equivalent explosives caused the same collapse mode while the collapsing duration was different. The airplane impacted at the throat of the cooling tower caused the local failure of shell structure of the tower, and then the progressive collapse of the cooling tower happened due to the gravitational action. The resulting collapse mode was different from that triggered by the local explosion

  17. Natural-draught cooling towers made of reinforced concrete

    International Nuclear Information System (INIS)

    Kraetzig, W.B.; Peters, H.L.; Zerna, W.

    1978-01-01

    Large power plant units and dry cooling tower technology require larger dimensions for natural-draught cooling towers. The main curvation radii in latitudinal and meridian direction are thus increased, which results in a lower three-dimensional support strength. This development is an incentive for constant re-consideration of calculation methods, safety philosophy, and dimensioning criteria. In this context, wind effects have been re-formulated and given a scientific foundation. Constructional measures to improve the static and dynamic behaviour of the structure have been presented and critically assessed. A cost analysis, finally, gave the most rational applications of the new shell construction with reinforcing elements. A cooling tower now under construction gave a realistic example. Fundamental aspects concerning the foundations of cooling tower shells and two special types of foundation are further points to clarify the subject. (orig./HP) [de

  18. TacTowers

    DEFF Research Database (Denmark)

    Ludvigsen, Martin; Fogtmann, Maiken Hillerup; Grønbæk, Kaj

    2010-01-01

    The interactive training equipment, TacTower, is aimed at supporting multiple elite athletes, such as handball players in training their micro-tactical skills in close-contact situations. It focuses on psychomotor abilities and trains the skills involved in reading the opponents’ actions and anti...... for the elite athletic community, as this domain holds interesting challenges while also inspiring relevant, new forms of interaction design for other domains....

  19. Dynamic behavior and identification of failure modes of cooling towers

    International Nuclear Information System (INIS)

    Serhan, S.J.

    1994-01-01

    The major thrust of this paper is to provide an engineering assessment of two hyperboloidal 540-foot high reinforced concrete cooling towers at a nuclear power plant relative to the proposed construction of a new safety-related facility in the shadow of these cooling towers. A three-dimensional full 360-degree finite-element model that is capable of realistically representing the response of the two cooling towers subjected to the plant design-basis safe shutdown earthquake, 90 mph wind, and 300 mph tornado is used to create a data pool which supports the proposed construction of the new facility. Dynamic time history analyses are performed to represent the complex interplay of the dynamic characteristics of the cooling towers and the input wind-pressure excitation in terms of gust factors. This study resulted in the confirmation and enhancement of many of the important aspects in the design/analysis methodologies for cooling towers reported in literature. In summary, this study provides a high confidence that no significant damage will be caused to the two cooling towers when subjected to the plant design-basis safe shutdown earthquake and the 90 mph basic wind velocity. However, the two cooling towers are expected to collapse if subjected in a direct hit to a 300 mph tornado. The nonlinear finite element analyses including base uplift performed for this study and the literature research on past failures of cooling towers due to severe wind storms confirm that the mode of failure will not be the overturning cantilever tree-type and the towers will collapse inwardly with the exception of few isolated debris

  20. Analytical Assessment of Environmental Impact for APR1400DC UHS Cooling Tower

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jaiho [KHNP-Central Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Hot process water is pumped from the plant process to the cooling towers. Heat is rejected through evaporation of the process water, interacting with ambient air blown upward by fans.. Plumes generated from exit ports of the cooling tower may have adverse effects on the environment, such as deposition of cooling tower drift release, fogging, icing, shadowing, and ground-level temperature and humidity increase. These kinds of environmental impact of the cooling tower are linked closely with the dispersion of the cooling tower plumes. In this respect, predicting the behavior of the plumes has become one of the most important issues in the environmental assessments of the cooling towers. The SACTI (seasonal/annual cooling tower impact) model is an analytical tool to predict the environmental effect of cooling tower, which was developed by Argonne National Laboratory and University of Illinois with support from EPRI (electric power research institute). The initial version of SACTI has been widely used to assess the environmental effect of cooling towers in many industrial fields such as steam power plants and NPPs. Guo et. al. investigated impact of heat rejection and cooling tower height on plume dispersion using the SACTI model, for the purpose of the future construction of inland NPPs. They found that increasing cooling tower height decreases the plume length and height frequencies. Their simulation results showed that the increase in heat rejection increases the plum radius frequency. The APR1400DC is an advanced light water reactor developed for the purpose of NRC-DC (design certification). The cooling towers for APR1400DC UHS consist of two linear mechanical draft cooling towers (LMDCTs). The LMDCT for APR1400DC UHS is conceptually designed because the plant site has not been decided yet. In the present study, the dependency of plume dispersion on the number of cooling towers is investigated using SACTI-2-beta, for predicting annual environmental effect of APR

  1. EFFECT OF THE FILL VENTILATION WINDOW ON PERFORMANCE OF A NATURAL DRAFT COOLING TOWER SUBJECTED TO CROSS-WINDS

    Directory of Open Access Journals (Sweden)

    K. V. Dobrego

    2016-01-01

    Full Text Available Various aerodynamic design elements and technics (wind deflectors, wind walls, etc. are utilized for improvement of the thermal efficiency of the natural draft cooling towers, particularly in conditions of cross wind. One of the technical methods, proposed by engineers of Belarus Academy of Sciences, is installation of the ventilation window in the center of the fill. This method is substantiated by the fact that the flow of cooling gas obtains maximum temperature and humidity near the center of the under-fill space of cooling tower and, as a consequence, performs minimal heat exchange. The influence of the fill ventilation window and wind deflectors in the inlet windows of the cooling tower on its thermal performance in condition of cross-wind is investigated in the paper numerically. The cooling tower of the “Woo-Jin” power plant (China 150 m of the height and 114 m of the base diameter was taken as a prototype. The analogy (equivalence between the heat and mass transfer was taken into consideration, which enabled us to consider single-phase flow and perform complicated 3D simulation by using modern personal computers. Heat transfer coefficient for the fill and its hydrodynamic resistance were defined by using actual data on total flow rate in the cooling tower. The numerical model and computational methods were tested and verified in numerous previous works. The non-linear dependence of the thermal performance of the cooling tower on wind velocity (with the minimum in vicinity of Ucr ~ 8 m/s for the simulated system was demonstrated. Calculations show that in the condition of the average wind speed the fill ventilation window doesn’t improve, but slightly decrease (by 3–7 % performance of the cooling tower. Situation changes in the condition of strong winds Ucw > 12 m/s, which are not typical for Belarus. Utilization of airflow deflectors at the inlet windows of cooling tower, conversely, increases thermal performance of the

  2. Radiation scanning aids tower diagnosis at Arun LNG plant

    International Nuclear Information System (INIS)

    Naklie, M.M.; Pless, L.; Gurning, T.P.; Hyasak, M.

    1990-01-01

    Radiation scanning has been used effectively to troubleshoot the treating towers of the Arun LNG plant in Sumatra, Indonesia. The plant is one of the world's largest such facilities. The analysis was part of an investigation aimed at increasing the capacity of the treater section of the plant. Radiation scanning is a tool which, in addition to tower differential pressure and product purity, can aid in diagnosing tower performance

  3. DEVELOPMENT OF METHODS FOR STABILITY ANALYSIS OF TOWER CRANES

    Directory of Open Access Journals (Sweden)

    Sinel'shchikov Aleksey Vladimirovich

    2018-01-01

    Full Text Available Tower cranes are one of the main tools for execution of reloading works during construction. Design of tower cranes is carried out in accordance with RD 22-166-86 “Construction of tower cranes. Rules of analysis”, according to which to ensure stability it is required not to exceed the overturning moment upper limit. The calculation of these moments is carried out with the use of empirical coefficients and quite time-consuming. Moreover, normative methodology only considers the static position of the crane and does not take into account the presence of dynamic transients due to crane functioning (lifting and swinging of the load, boom turning and the presence of the dynamic external load (e.g. from wind for different orientations of the crane. This paper proposes a method of determining the stability coefficient of the crane based on acting reaction forces at the support points - the points of contact of wheels with the crane rail track, which allows us, at the design stage, to investigate stability of tower crane under variable external loads and operating conditions. Subject: the safety of tower cranes operation with regard to compliance with regulatory requirements of ensuring their stability both at the design stage and at the operational stage. Research objectives: increasing the safety of operation of tower cranes on the basis of improving methodology of their design to ensure static and dynamic stability. Materials and methods: analysis and synthesis of the regulatory framework and modern research works on provision of safe operation of tower cranes, the method of numerical simulation. Results: we proposed the formula for analysis of stability of tower cranes using the resulting reaction forces at the supports of the crane at the point of contact of the wheel with the rail track.

  4. Optimization of cooling tower performance analysis using Taguchi method

    Directory of Open Access Journals (Sweden)

    Ramkumar Ramakrishnan

    2013-01-01

    Full Text Available This study discuss the application of Taguchi method in assessing maximum cooling tower effectiveness for the counter flow cooling tower using expanded wire mesh packing. The experiments were planned based on Taguchi’s L27 orthogonal array .The trail was performed under different inlet conditions of flow rate of water, air and water temperature. Signal-to-noise ratio (S/N analysis, analysis of variance (ANOVA and regression were carried out in order to determine the effects of process parameters on cooling tower effectiveness and to identity optimal factor settings. Finally confirmation tests verified this reliability of Taguchi method for optimization of counter flow cooling tower performance with sufficient accuracy.

  5. Solution and scope of utilization of the cross-stream cooling towers

    International Nuclear Information System (INIS)

    Zembaty, W.

    1995-01-01

    Technical solutions and operational properties of the cross-stream cooling towers as well as the scope of their utilization are presented. The differences within thermodynamic calculations of the cross-stream and counter-stream cooling towers due to the direction of the air flow as well as water flow in sprinkling system are discussed. The assessment of the capital and operational costs of the cross-stream cooling towers is given and compared with the cost of counter-stream cooling towers (utilizing as an example a calculation conducted for the cooling towers of the 720, 1100 and 1400 MW units). (author). 6 refs, 9 figs

  6. Evaluation of the seismic response of historical masonry bell towers located in South-East Lombardy, Italy

    Science.gov (United States)

    Valente, Marco; Milani, Gabriele; Shehu, Rafael

    2017-07-01

    This study presents some FE results regarding the behavior under horizontal loads of two existing masonry towers located in South-East Lombardy, Italy. The towers, albeit unique for geometric and architectural features, show some affinities that justify a comparative analysis, as for instance the location and the similar masonry material. Their structural behavior under horizontal loads is therefore influenced by geometrical issues, such as slenderness, walls thickness, perforations, irregularities, presence of internal vaults, etc., which may be responsible for a peculiar output. The geometry of the towers is deduced from both existing available documentation and in-situ surveys. On the basis of such geometrical data, a detailed 3D realistic mesh is conceived, with a point by point characterization of each single geometric element. The FE models are analyzed under seismic loads acting along geometric axes of the plan section, with non-linear dynamic excitation assumptions. A damage-plasticity material model exhibiting softening in both tension and compression, already available in the commercial code Abaqus, is used for masonry. Non-linear dynamic analyses are performed along both the X and Y directions with a real accelerogram scaled to different peak ground accelerations. Some results presented in this paper show the high vulnerability of ancient masonry towers under horizontal loads.

  7. FLUXNET: A Global Network of Eddy-Covariance Flux Towers

    Science.gov (United States)

    Cook, R. B.; Holladay, S. K.; Margle, S. M.; Olsen, L. M.; Gu, L.; Heinsch, F.; Baldocchi, D.

    2003-12-01

    The FLUXNET global network was established to aid in understanding the mechanisms controlling the exchanges of carbon dioxide, water vapor, and energy across a variety of terrestrial ecosystems. Flux tower data are also being used to validate ecosystem model outputs and to provide information for validating remote sensing based products, including surface temperature, reflectance, albedo, vegetation indices, leaf area index, photosynthetically active radiation, and photosynthesis derived from MODIS sensors on the Terra and Aqua satellites. The global FLUXNET database provides consistent and complete flux data to support global carbon cycle science. Currently FLUXNET consists of over 210 sites, with most flux towers operating continuously for 4 years or longer. Gap-filled data are available for 53 sites. The FLUXNET database contains carbon, water vapor, sensible heat, momentum, and radiation flux measurements with associated ancillary and value-added data products. Towers are located in temperate conifer and broadleaf forests, tropical and boreal forests, crops, grasslands, chaparral, wetlands, and tundra on five continents. Selected MODIS Land products in the immediate vicinity of the flux tower are subsetted and posted on the FLUXNET Web site for 169 flux-towers. The MODIS subsets are prepared in ASCII format for 8-day periods for an area 7 x 7 km around the tower.

  8. Numerical Simulation of Tower Rotor Interaction for Downwind Wind Turbine

    Directory of Open Access Journals (Sweden)

    Isam Janajreh

    2010-01-01

    Full Text Available Downwind wind turbines have lower upwind rotor misalignment, and thus lower turning moment and self-steered advantage over the upwind configuration. In this paper, numerical simulation to the downwind turbine is conducted to investigate the interaction between the tower and the blade during the intrinsic passage of the rotor in the wake of the tower. The moving rotor has been accounted for via ALE formulation of the incompressible, unsteady, turbulent Navier-Stokes equations. The localized CP, CL, and CD are computed and compared to undisturbed flow evaluated by Panel method. The time history of the CP, aerodynamic forces (CL and CD, as well as moments were evaluated for three cross-sectional tower; asymmetrical airfoil (NACA0012 having four times the rotor's chord length, and two circular cross-sections having four and two chords lengths of the rotor's chord. 5%, 17%, and 57% reductions of the aerodynamic lift forces during the blade passage in the wake of the symmetrical airfoil tower, small circular cross-section tower and large circular cross-section tower were observed, respectively. The pronounced reduction, however, is confined to a short time/distance of three rotor chords. A net forward impulsive force is also observed on the tower due to the high speed rotor motion.

  9. Wind-induced Vibrations in the European Court Towers

    DEFF Research Database (Denmark)

    Hansen, Jannick B.; Brincker, Rune; Andersen, Ken G.

    2012-01-01

    Issues regarding occupancy comfort in vibration-sensitive structures are the motivation of this study concerning windinduced vibrations in the European Court Towers in Luxembourg. In one of the two identical towers tuned liquid dampers (TLD) have been installed. Recent studies investigate the cha...

  10. Reality based optimization of steel monopod offshore-towers

    NARCIS (Netherlands)

    Vrouwenvelder, A.C.W.M.

    2008-01-01

    In this work, the implementation of reliability-based optimization (RBO) of a circular steel monopod-offshore-tower with constant and variable diameters (represented by segmentations) and thicknesses is presented. The tower is subjected to the extreme wave loading. For this purpose, the

  11. Construction of cable-stayed prestressed concrete bridge, having Japan`s first independent single slanted tower; Nippon hatsu no keisha shuto wo motsu PC shachokyo no seko

    Energy Technology Data Exchange (ETDEWEB)

    Sanada, Y.; Naito, H. [Penta-Ocean Construction Co. Ltd., Tokyo (Japan); Takeuchi, H.; Mikami, T.

    1994-08-01

    In the Hachinoe Harbor, Aomori prefecture, a man-made island (Hachinoe Port Island) is being constructed by reclamation. When proceeding this undertaking plan, a construction of the Hachinoe Harbor Port Island connection bridge, which connects the man-made island with the existing harbor district, was made an urgent necessity. This connecting bridge is a bridge with a total length of 256.56m, and is constituted of two span continuous PC slanted bridge and three span continuous PC box girder bridge. This slanted bridge has become an asymmetrical structure due to several conditions coming from a plan, and moreover it has the first structural shape as a road bridge in Japan, of which main tower is 15{degree} slanted independent single tower type, there are more problems for the work execution compared with other normal slanted bridges. In addition, because it is situated in an extremely cruel environment like in the cold region and in the marine environment, a sufficient consideration is required for its design and work execution in order to insure a durability. In this report, an outline of work execution content about PC slanted bridge part currently under a construction zealously aiming at a completion in the end of the fiscal year 1994 is introduced. 2 refs., 14 figs., 4 tabs.

  12. Cooling tower wood sampling and analyses: A case study

    International Nuclear Information System (INIS)

    Haymore, J.L.

    1985-01-01

    Extensive wood sampling and analyses programs were initiated on crossflow and counterflow cooling towers that have been in service since 1951 and 1955, respectively. Wood samples were taken from all areas of the towers and were subjected to biological, chemical and physical tests. The tests and results for the analyses are discussed. The results indicate the degree of wood deterioration, and areas of the towers which experience the most advanced degree of degradation

  13. X-ray Observations at Gaisberg Tower

    Directory of Open Access Journals (Sweden)

    Pasan Hettiarachchi

    2018-01-01

    Full Text Available We report the occurrence of X-rays at ground level due to cloud-to-ground flashes of upward-initiated lightning from Gaisberg Tower, in Austria, which is located at an altitude of 1300 m. This is the first observation of X-ray emissions from upward lightning from a tower top located at high altitude. Measurements were carried out using scintillation detectors installed close to the tower top in two phases from 2011 to 2015. X-rays were recorded in three subsequent strokes of three flashes out of the total of 108 flashes recorded in the system during both phases. In contrast to the observations from downward natural or triggered lightning, X-rays were observed only within 10 µs before the subsequent return stroke. This shows that X-rays were emitted when the dart leader was in the vicinity of the tower top, hence during the most intense phase of the dart leader. Both the detected energy and the fluence of X-rays are far lower compared to X-rays from downward natural or rocket-triggered lightning. In addition to the above 108 flashes, an interesting observation of X-rays produced by a nearby downward flash is also presented. The shorter length of dart-leader channels in Gaisberg is suggested as a possible cause of this apparently weaker X-ray production.

  14. 75 FR 63802 - Action Affecting Export Privileges; Parto Abgardan Cooling Towers Co.

    Science.gov (United States)

    2010-10-18

    ... Abgardan Cooling Towers Co. Parto Abgardan Cooling Towers Co., P.O. Box 966, Folsom, CA 95763; and P.O. Box... Making Denial of Export Privileges of Aqua-Loop Cooling Towers, Co. Applicable to Parto Abgardan Cooling...-Loop Cooling Towers, Co. (``Aqua-Loop'') on March 25, 2010 (``Denial Order''), applicable to the...

  15. The optimal operation of cooling tower systems with variable-frequency control

    Science.gov (United States)

    Cao, Yong; Huang, Liqing; Cui, Zhiguo; Liu, Jing

    2018-02-01

    This study investigates the energy performance of chiller and cooling tower systems integrated with variable-frequency control for cooling tower fans and condenser water pumps. With regard to an example chiller system serving an office building, Chiller and cooling towers models were developed to assess how different variable-frequency control methods of cooling towers fans and condenser water pumps influence the trade-off between the chiller power, pump power and fan power under various operating conditions. The matching relationship between the cooling tower fans frequency and condenser water pumps frequency at optimal energy consumption of the system is introduced to achieve optimum system performance.

  16. Legionella safety in cooling towers; Legionellaveiligheid in koeltorens

    Energy Technology Data Exchange (ETDEWEB)

    Kordes, B. [Kordes Advies, (Netherlands); De Bok, F. [KBBL Wijhe, (Netherlands); De Zeeuw, L. [Holland Environment Group, (Netherlands); Settels, P. [Safety, Health Services and Ergonomics, ING, (Netherlands); Oesterholt, F.; Wullings, B. [KWR Watercycle Research Institute, (Netherlands); Guiot, P. [Tevan, Gorinchem (Netherlands); Brands, R. [Cumulus Nederland, Cuijk (Netherlands); Nuijten, O. [Kennisinstituut ISSO, Rotterdam (Netherlands); Wijne, R. [Beer advocaten, Amsterdam (Netherlands)

    2010-04-15

    In 9 articles attention is paid to several aspects with regard to Legionella in cooling towers: representative sampling, the use of copper and silver ionization or hydrogen peroxide to prevent Legionella growth and biofilms, the use of a zero-tolerance model to control a cooling tower installation, detection of DNA of Legionella Pneumophila, legionella safety in air conditioners, the model Legionella risk analysis and control of cooling tower installations, legislation and regulations for the control of cooling tower installations with regard to the Dutch Occupational Health and Safety Act ('Arbo-wet'), and an article about a lawsuit for victims of a Legionella outbreak, caused by careless owners of a cooling tower in Amsterdam, Netherlands. [Dutch] In 9 artikelen wordt in deze aflevering aandacht besteed aan verschillende aspecten m.b.t. Legionella in koeltorens: representatieve monstername, de toepassing van koper en zilver-ionisatie of waterstofperoxide om de groei van Legionella en biofilms te voorkomen, het gebruik van een zero-tolerance model om een koeltoren installatie te controleren, detectie van DNA van Legionella Pneumophila, Legionella veiligheid in luchtbehandelingsinstallaties, het model Legionella risicoanalyse en beheersplan voor koeltoreninstallaties, de rol van de Arbo-wet, en een artikel over een rechtszaak voor slachtoffers van Legionella door onzorgvuldig beheer van een koeltoren in Amsterdam.

  17. Use of cooling tower blow down in ethanol fermentation.

    Science.gov (United States)

    Rajagopalan, N; Singh, V; Panno, B; Wilcoxon, M

    2010-01-01

    Reducing water consumption in bioethanol production conserves an increasingly scarce natural resource, lowers production costs, and minimizes effluent management issues. The suitability of cooling tower blow down water for reuse in fermentation was investigated as a means to lower water consumption. Extensive chemical characterization of the blow down water revealed low concentrations of toxic elements and total dissolved solids. Fermentation carried out with cooling tower blow down water resulted in similar levels of ethanol and residual glucose as a control study using deionized water. The study noted good tolerance by yeast to the specific scale and corrosion inhibitors found in the cooling tower blow down water. This research indicates that, under appropriate conditions, reuse of blow down water from cooling towers in fermentation is feasible.

  18. Aerosol optical properties derived from the DRAGON-NE Asia campaign, and implications for a single-channel algorithm to retrieve aerosol optical depth in spring from Meteorological Imager (MI on-board the Communication, Ocean, and Meteorological Satellite (COMS

    Directory of Open Access Journals (Sweden)

    M. Kim

    2016-02-01

    Full Text Available An aerosol model optimized for northeast Asia is updated with the inversion data from the Distributed Regional Aerosol Gridded Observation Networks (DRAGON-northeast (NE Asia campaign which was conducted during spring from March to May 2012. This updated aerosol model was then applied to a single visible channel algorithm to retrieve aerosol optical depth (AOD from a Meteorological Imager (MI on-board the geostationary meteorological satellite, Communication, Ocean, and Meteorological Satellite (COMS. This model plays an important role in retrieving accurate AOD from a single visible channel measurement. For the single-channel retrieval, sensitivity tests showed that perturbations by 4 % (0.926 ± 0.04 in the assumed single scattering albedo (SSA can result in the retrieval error in AOD by over 20 %. Since the measured reflectance at the top of the atmosphere depends on both AOD and SSA, the overestimation of assumed SSA in the aerosol model leads to an underestimation of AOD. Based on the AErosol RObotic NETwork (AERONET inversion data sets obtained over East Asia before 2011, seasonally analyzed aerosol optical properties (AOPs were categorized by SSAs at 675 nm of 0.92 ± 0.035 for spring (March, April, and May. After the DRAGON-NE Asia campaign in 2012, the SSA during spring showed a slight increase to 0.93 ± 0.035. In terms of the volume size distribution, the mode radius of coarse particles was increased from 2.08 ± 0.40 to 2.14 ± 0.40. While the original aerosol model consists of volume size distribution and refractive indices obtained before 2011, the new model is constructed by using a total data set after the DRAGON-NE Asia campaign. The large volume of data in high spatial resolution from this intensive campaign can be used to improve the representative aerosol model for East Asia. Accordingly, the new AOD data sets retrieved from a single-channel algorithm, which uses a precalculated look-up table (LUT with the new aerosol model

  19. A New Type of Captive Balloon for Vertical Meteorological Observation in Urban Area

    Science.gov (United States)

    Nakamura, M.; Sakai, S.; Ono, K.

    2010-12-01

    Many meteorological observations in urban area have been made in recent years in order to investigate the mechanism of heat island. However, there are few data of cooling process in urban area. For this purpose, high density observations in both space and time are required. Generally vertical meteorological observations can be made by towers, radars, balloons. These methods are limited by urban area conditions. Among these methods, a captive balloon is mainly used to about a hundred meter from ground in a vertical meteorological observation. Small airships called kytoons or advertising balloons, for example. Conventional balloons are, however, influenced by the wind and difficult to keep the specified position. Moreover, it can be dangerous to conduct such observations in the highly build-up area. To overcome these difficulties, we are developing a new type of captive balloon. It has a wing form to gain lift and keep its position. It is also designed small to be kept in a carport. It is made of aluminum film and polyester cloth in order to attain lightweight solution. We have tried floating a balloon like NACA4424 for several years. It was difficult to keep a wing form floating up over 100 meters from ground because internal pressure was decreased by different temperature. The design is changed in this year. The balloon that has wing form NACA4415 is similar in composition to an airplane. It has a big gasbag with airship form and two wing form. It is able to keep form of a wing by high internal pressure. We will report a plan for the balloon and instances of some observations.

  20. Cooling towers in the landscape

    International Nuclear Information System (INIS)

    Boernke, F.

    1977-01-01

    The cooling tower as a large technical construction is one of the most original industrial buildings. It sticks out as an outlandish element in our building landscape, a giant which cannot be compared with the traditional forms of technical buildings. If it is constructed as a reinforced-concrete hyperboloid, its shape goes beyond all limits of building construction. Judgment of these highly individual constructions is only possible by applying a novel standard breaking completely with tradition. This new scale of height and dimension in industrial construction, and in particular the modern cooling tower, requires painstaking care and design and adaptation to the landscape around it. (orig.) [de

  1. Windfarms and telecommunications towers (Scotland)

    Energy Technology Data Exchange (ETDEWEB)

    Munro, Hector; Kellett-Bowman, Elaine; Harris, David [and others

    1996-10-30

    A debate in the United Kingdom House of Commons on the environmental impact of windfarms and telecommunications towers in Scotland is reported. Concern was expressed over the adverse visual impact of such structures in rural areas which are often of considerable natural beauty. Counter arguments were based on the positive effects of new technology. The need to reconcile environmental protection with technological innovation was expressed. A Government spokesman described the comprehensive planning policy framework which has been put in place to secure sound planning decisions on renewable energy developments and the conditions on amenity protection in the regulations governing the erection of telecommunications towers. (UK)

  2. Windfarms and telecommunications towers (Scotland)

    International Nuclear Information System (INIS)

    Munro, Hector; Kellett-Bowman, Elaine; Harris, David

    1996-01-01

    A debate in the United Kingdom House of Commons on the environmental impact of windfarms and telecommunications towers in Scotland is reported. Concern was expressed over the adverse visual impact of such structures in rural areas which are often of considerable natural beauty. Counter arguments were based on the positive effects of new technology. The need to reconcile environmental protection with technological innovation was expressed. A Government spokesman described the comprehensive planning policy framework which has been put in place to secure sound planning decisions on renewable energy developments and the conditions on amenity protection in the regulations governing the erection of telecommunications towers. (UK)

  3. Performance Evaluation of a Modular Design of Wind Tower with Wetted Surfaces

    Directory of Open Access Journals (Sweden)

    Sajad M.R. Khani

    2017-06-01

    Full Text Available Wind towers or wind catchers, as passive cooling systems, can provide natural ventilation in buildings located in hot, arid regions. These natural cooling systems can provide thermal comfort for the building inhabitants throughout the warm months. In this paper, a modular design of a wind tower is introduced. The design, called a modular wind tower with wetted surfaces, was investigated experimentally and analytically. To determine the performance of the wind tower, air temperature, relative humidity (RH and air velocity were measured at different points. Measurements were carried out when the wind speed was zero. The experimental results were compared with the analytical ones. The results illustrated that the modular wind tower can decrease the air temperature significantly and increase the relative humidity of airflow into the building. The average differences for air temperature and air relative humidity between ambient air and air exiting from the wind tower were approximately 10 °C and 40%, respectively. The main advantage of the proposed wind tower is that it is a modular design that can reduce the cost of wind tower construction.

  4. Determination of the replacement cooling tower capability at the ETRR-2 research reactor

    International Nuclear Information System (INIS)

    El-Din El-Morshdy, S.

    2004-01-01

    The ETRR-2 replacement cooling tower capability has been evaluated by the thermal acceptance test performed in June 2003. All instruments used were calibrated prior to the test. The measured data are collected at regular intervals in accordance with the acceptance test code for water cooling towers of the cooling tower institute recommendations. Both the characteristic curve and the performance curve methods were used to evaluate the tower capability. The test results yield a tower capability of about 105% and so the tower is thermally accepted. (orig.)

  5. Wind turbine generator application places unique demands on tower design and materials

    Science.gov (United States)

    Kita, J. P.

    1978-01-01

    The most relevant contractual tower design requirements and goal for the Mod-1 tower are related to steel truss tower construction, cost-effective state-of-the-art design, a design life of 30 years, and maximum wind conditions of 120 mph at 30 feet elevation. The Mod-1 tower design approach was an iterative process. Static design loads were calculated and member sizes and overall geometry chosen with the use of finite element computer techniques. Initial tower dynamic characteristics were then combined with the dynamic properties of the other wind turbine components, and a series of complex dynamic computer programs were run to establish a dynamic load set and then a second tower design.

  6. Meteorology Products - Naval Oceanography Portal

    Science.gov (United States)

    section Advanced Search... Sections Home Time Earth Orientation Astronomy Meteorology Oceanography Ice You are here: Home › FNMOC › Meteorology Products FNMOC Logo FNMOC Navigation Meteorology Products Oceanography Products Tropical Applications Climatology and Archived Data Info Meteorology Products Global

  7. Meteorological Monitoring Program

    International Nuclear Information System (INIS)

    Hancock, H.A. Jr.; Parker, M.J.; Addis, R.P.

    1994-01-01

    The purpose of this technical report is to provide a comprehensive, detailed overview of the meteorological monitoring program at the Savannah River Site (SRS) near Aiken, South Carolina. The principle function of the program is to provide current, accurate meteorological data as input for calculating the transport and diffusion of any unplanned release of an atmospheric pollutant. The report is recommended for meteorologists, technicians, or any personnel who require an in-depth understanding of the meteorological monitoring program

  8. Meteorological Monitoring Program

    Energy Technology Data Exchange (ETDEWEB)

    Hancock, H.A. Jr. [ed.; Parker, M.J.; Addis, R.P.

    1994-09-01

    The purpose of this technical report is to provide a comprehensive, detailed overview of the meteorological monitoring program at the Savannah River Site (SRS) near Aiken, South Carolina. The principle function of the program is to provide current, accurate meteorological data as input for calculating the transport and diffusion of any unplanned release of an atmospheric pollutant. The report is recommended for meteorologists, technicians, or any personnel who require an in-depth understanding of the meteorological monitoring program.

  9. The caracol tower at chichen itza: an ancient astronomical observatory?

    Science.gov (United States)

    Aveni, A F; Gibbs, S L; Hartung, H

    1975-06-06

    platforms of the Caracol seem to have been laid out deliberately to point to horizon events involving the sun and the planet Venus. Of the lines taken through the windows, the Venus setting points seem most plausible to us in view of both the accuracy with which they fit the architecture and the historical evidence bearing upon the importance of Venus to the Mesoamerican people. A specific connection between the Venus calendar in the Dresden Codex and the sighting of the extreme positions of the planet along the horizon, however, is yet to be established. It is especially significant that alignments in both the base and the top of the tower relate to Venus. The solar equinox alignment in window I remains problematical, although the arrangement probably functioned as an approximate means of determining the first day of spring and the first day of autumn. Lines pointing to individual bright stars undoubtedly should be given lower value. If one is willing to carry the matching game to its ultimate completion, a stellar object can always be found which, although very obscure, will fit an alignment. In our consideration of the problem we have attempted to single out bright stars which appeared or disappeared on significant calendar dates. Other round structures resembling the Caracol exist in Mesoamerica (20), although there are comparatively few built by the Maya. Nearly all can be attributed to the cult of Quetzalcoatl (34). To our knowledge none have been carefully measured and analyzed for astronomical orientations. The ruined tower Q-152 at Mayapan bore distinct similarities to the Caracol, both in shape and structure. It probably contained only a single doorway which faced west. Both structures possessed circular corridors. A circular tower is still standing at Paalmul on the coast of Quintana Roo north of Tulum. Pollock (20, p. 115) states that it has a single room in the turret. A window similar to No. I in the Caracol faces northwest, the same direction as the base of

  10. Lower parts of Temelin nuclear power plant cooling towers

    International Nuclear Information System (INIS)

    Sebek, J.

    1988-01-01

    The progress of work is described in detail on the foundations and lower parts of the cooling towers of the Temelin nuclear power plant. The cooling tower is placed on a reinforced concrete footing of a circular layout. Support pillars are erected on the reinforced concrete continuous footing. They consists of oblique shell stanchions. Inside, the footing joins up to monolithic wall and slab structures of the cooling tower tub. The tub bottom forms a foundation plate supporting prefab structures of the cooling tower inner structural systems. The framed support of the chimney shell consists of 56 pairs of prefabricated oblique stanchions. Following their erection into the final position and anchoring in the continuous footing, the concreting of the casing can start of the reinforced conrete chimney. (Z.M.). 3 figs

  11. Parametric study of closed wet cooling tower thermal performance

    Science.gov (United States)

    Qasim, S. M.; Hayder, M. J.

    2017-08-01

    The present study involves experimental and theoretical analysis to evaluate the thermal performance of modified Closed Wet Cooling Tower (CWCT). The experimental study includes: design, manufacture and testing prototype of a modified counter flow forced draft CWCT. The modification based on addition packing to the conventional CWCT. A series of experiments was carried out at different operational parameters. In view of energy analysis, the thermal performance parameters of the tower are: cooling range, tower approach, cooling capacity, thermal efficiency, heat and mass transfer coefficients. The theoretical study included develops Artificial Neural Network (ANN) models to predicting various thermal performance parameters of the tower. Utilizing experimental data for training and testing, the models simulated by multi-layer back propagation algorithm for varying all operational parameters stated in experimental test.

  12. Transient Simulation of Wind Turbine Towers under Lightning Stroke

    Directory of Open Access Journals (Sweden)

    Xiaoqing Zhang

    2013-01-01

    Full Text Available A simulation algorithm is proposed in this paper for lightning transient analysis of the wind turbine (WT towers. In the proposed algorithm, the tower body is first subdivided into a discrete multiconductor system. A set of formulas are given to calculate the electrical parameters of the branches in the multiconductor system. By means of the electrical parameters, each branch unit in the multiconductor system is replaced as a coupled π-type circuit and the multiconductor system is converted into a circuit model. Then, the lightning transient responses can be obtained in different parts on the tower body by solving the circuit equations of the equivalent discretization network. The laboratory measurement is also made by a reduced-scale tower for checking the validity of the proposed algorithm.

  13. Exergy analysis of a distillation tower for crude oil fractionation

    International Nuclear Information System (INIS)

    Rivero, R.

    1990-01-01

    In this paper the application of the exergy method to a crude oil atmospheric distillation tower is presented. The fundamentals and procedures are presented as well as the main parameters used to describe the thermodynamic performance of the system, such as Exergy Losses, Effectiveness and Improvement Potential. A parametric analysis of the influence on the effectiveness of the tower is then performed as a function of the number of trays, the amount of stripping steam, the use of reboilers and the operation pressure. The results obtained are discussed. As expected, the effectiveness of the tower increases with the overall number of trays in the tower and in the stripping columns for a constant operation pressure and a constant amount of stripping steam but there is a limit at which the pressure drop across the trays and the stripping steam requirements make the effectiveness decrease. The use of reboilers in the stripping columns adjacent to the main tower allows an increase in the effectiveness basically due to a greater heat integration. Finally, the increase in the operation pressure of the tower produces an increase of the effectiveness but also an increase in the stripping steam requirements

  14. 78 FR 10210 - Utility Scale Wind Towers From China and Vietnam

    Science.gov (United States)

    2013-02-13

    ... wind towers. Background The Commission instituted these investigations effective December 29, 2011...)] Utility Scale Wind Towers From China and Vietnam Determinations On the basis of the record \\1\\ developed... with material injury by reason of imports of utility scale wind towers from China and Vietnam, provided...

  15. A METEOROLOGICAL RISK ASSESSMENT METHOD FOR POWER LINES BASED ON GIS AND MULTI-SENSOR INTEGRATION

    Directory of Open Access Journals (Sweden)

    Z. Lin

    2016-06-01

    Full Text Available Power lines, exposed in the natural environment, are vulnerable to various kinds of meteorological factors. Traditional research mainly deals with the influence of a single meteorological condition on the power line, which lacks of comprehensive effects evaluation and analysis of the multiple meteorological factors. In this paper, we use multiple meteorological monitoring data obtained by multi-sensors to implement the meteorological risk assessment and early warning of power lines. Firstly, we generate meteorological raster map from discrete meteorological monitoring data using spatial interpolation. Secondly, the expert scoring based analytic hierarchy process is used to compute the power line risk index of all kinds of meteorological conditions and establish the mathematical model of meteorological risk. By adopting this model in raster calculator of ArcGIS, we will have a raster map showing overall meteorological risks for power line. Finally, by overlaying the power line buffer layer to that raster map, we will get to know the exact risk index around a certain part of power line, which will provide significant guidance for power line risk management. In the experiment, based on five kinds of observation data gathered from meteorological stations in Guizhou Province of China, including wind, lightning, rain, ice, temperature, we carry on the meteorological risk analysis for the real power lines, and experimental results have proved the feasibility and validity of our proposed method.

  16. Meteorological tower data for the Yucca Alluvial (YA) site and Yucca Ridge (YR) site: Final data report, July 1983-October 1984

    International Nuclear Information System (INIS)

    Church, H.W.; Freeman, D.L.; Boro, K.; Egami, R.T.

    1987-11-01

    The purpose of the NNWSI meteorological data collection program was to support environmental evaluations of site suitability for a nuclear waste repository. This is the last of a series of data summaries for the NNWSI Alluvial and Ridge Sites in southern Nevada. 3 refs., 3 figs., 6 tabs

  17. Seismic response analysis of column supported natural draught cooling tower shells

    International Nuclear Information System (INIS)

    Ramanjaneyulu, K.; Gopalakrishnan, S.; Appa Rao, T.V.S.R.

    2003-01-01

    Natural draught cooling towers (NDCTs) belong to the category of large civil engineering structures and are commonly used in nuclear or thermal power plants. Detailed dynamic analysis has to be carried out for design of cooling towers subjected to seismic excitation, considering the flexibility of the columns. Finite ring element formulations for dynamic analysis of cooling tower shell subjected to seismic excitation are presented in this paper. The geometry of a typical tall natural draught cooling tower is considered in this study for carrying out investigations. Transient response of the hyperbolic cooling tower shell subjected to earthquake loading has been analysed by direct time integration using acceleration-time history of North-South component of El-Centro earthquake. Parametric studies have also been carried out to study the influence of flexibility of column supports and damping on the seismic response of cooling tower shell and the results are discussed in the paper. (author)

  18. Structural problems in the construction of natural draught cooling towers

    International Nuclear Information System (INIS)

    Zerna, W.

    1977-01-01

    The paper deals with the structural requirements and development possibilities for large cooling towers, and in particular discusses parameter investigations into the reinforcement of cooling tower shells and problems of optimisation. In conclusion proposals are made as to how concrete cooling towers of very large dimensions reinforced with steel, as for example are required in dry cooling for large capacity plant, can be developed economically. (orig.) [de

  19. Experimenting with sodar in support of emergency preparedness at Three Mile Island-1

    International Nuclear Information System (INIS)

    Heck, W.J.

    1989-01-01

    In November 1988 at Three Mile Island Unit 1 (TMI-1), GPU Nuclear successfully completed the annual drill-for-grade that, from a modeling point of view, broke new ground for this plant. The meteorological and modeling aspects of the drill scenario were unprecedented for two reasons. First, the plume was buoyant and rose far above the height of the meteorological tower located at TMI. Second, the wind direction data from the meteorological tower were not representative of the wind direction at plume height. In the drill scenario, the buoyant plume resulted from a steam generator tube rupture where the steam ejects directly into the atmosphere via safety relief valves. Plume modeling indicated that the plume would rise to 400 ft, given the scenario meteorology. Wind data from the on-site meteorological tower, however, was only available up to 150 ft. Comparisons of sodar and tower winds were made for various weather conditions. Sodar results were studied in detail during light, moderate, and high winds; various wind directions; occurrences of rain and snow; and by time of day to determine effects of diurnal meteorological conditions on sodar performance

  20. Numerical study of coupled heat and mass transfer in geothermal water cooling tower

    International Nuclear Information System (INIS)

    Bourouni, K.; Bassem, M.M.; Chaibi, M.T.

    2008-01-01

    Cross flow mechanical cooling towers, widely spreads all over the south region of Tunisia are used for cooling geothermal water for agriculture and domestic ends. These towers are sized empirically and present several problems in regard to operation and electrical energy consumption. This work aims to study the thermal behaviour of this type of cooling towers through a developed mathematical model considering the variation of the water mass flow rate inside the tower. The analysis of the water and air temperatures distribution along the cooling tower had underlined the negative convection phenomenon at a certain height of the tower. This analysis has shown also that the difference in water temperature between the inlet and the outlet of the tower is much higher than the one of air due to the dominance of the evaporative potential compared to the convective one. In addition, the variations of the air humidity along the cooling tower and the quantity of evaporated water have been investigated. The loss of water by evaporation is found to be 5.1% of the total quantity of water feeding the cooling tower. Interesting future prospects are expected for validation of the developed model to optimize the operating of the cooling tower

  1. Large wet-type cooling towers and their influence on the environment

    International Nuclear Information System (INIS)

    Schiffers, A.

    1977-01-01

    Large wet-type cooling towers with natural draft are said to be ecologically beneficial today, especially concerning the heat emission from power plants. A description is given of the influence of such cooling towers on the environment and the possible climatic influences are considered in detail. Recent investigations have shown that wet-type cooling towers represent no danger of any kind for fauna and flora as to the bacterial radiation. Physical studies have shown that neither the emitted water vapour nor the heat emitted into the atmosphere, can significantly change the macroclimate and microclimate. At present, wet-type cooling towers cannot be replaced by dry-type or so-called hybrid-type cooling towers, the technical development of which for large units being not yet guaranteed. (orig.) [de

  2. System and method for aligning heliostats of a solar power tower

    Science.gov (United States)

    Convery, Mark R.

    2013-01-01

    Disclosed is a solar power tower heliostat alignment system and method that includes a solar power tower with a focal area, a plurality of heliostats that each reflect sunlight towards the focal area of the solar power tower, an off-focal area location substantially close to the focal area of the solar power tower, a communication link between the off-focal area location and a misaligned heliostat, and a processor that interprets the communication between the off-focal area location and the misaligned heliostat to identify the misaligned heliostat from the plurality of heliostats and that determines a correction for the identified misaligned heliostat to realign the misaligned heliostat to reflect sunlight towards the focal area of the solar power tower.

  3. Contrastive analysis of cooling performance between a high-level water collecting cooling tower and a typical cooling tower

    Science.gov (United States)

    Wang, Miao; Wang, Jin; Wang, Jiajin; Shi, Cheng

    2018-02-01

    A three-dimensional (3D) numerical model is established and validated for cooling performance optimization between a high-level water collecting natural draft wet cooling tower (HNDWCT) and a usual natural draft wet cooling tower (UNDWCT) under the actual operation condition at Wanzhou power plant, Chongqing, China. User defined functions (UDFs) of source terms are composed and loaded into the spray, fill and rain zones. Considering the conditions of impact on three kinds of corrugated fills (Double-oblique wave, Two-way wave and S wave) and four kinds of fill height (1.25 m, 1.5 m, 1.75 m and 2 m), numerical simulation of cooling performance are analysed. The results demonstrate that the S wave has the highest cooling efficiency in three fills for both towers, indicating that fill characteristics are crucial to cooling performance. Moreover, the cooling performance of the HNDWCT is far superior to that of the UNDWCT with fill height increases of 1.75 m and above, because the air mass flow rate in the fill zone of the HNDWCT improves more than that in the UNDWCT, as a result of the rain zone resistance declining sharply for the HNDWCT. In addition, the mass and heat transfer capacity of the HNDWCT is better in the tower centre zone than in the outer zone near the tower wall under a uniform fill layout. This behaviour is inverted for the UNDWCT, perhaps because the high-level collection devices play the role of flow guiding in the inner zone. Therefore, when non-uniform fill layout optimization is applied to the HNDWCT, the inner zone increases in height from 1.75 m to 2 m, the outer zone reduces in height from 1.75 m to 1.5 m, and the outlet water temperature declines approximately 0.4 K compared to that of the uniform layout.

  4. Biofouling control of industrial seawater cooling towers

    KAUST Repository

    Al-Bloushi, Mohammed

    2017-01-01

    In this study, the research focuses on biofouling control in seawater cooling towers by investigating two different approaches. The first strategy addresses the use of alternative oxidants (i.e. ozone micro-bubbles and chlorine dioxide) in treatment of cooling towers. The second strategy investigates removing nutrients in seawater using granular activated carbon filter column and ultrafiltration to prevent the growth of microorganisms. Laboratory bench-scale tests in terms of temperature, cycle of concentration, dosage, etc. indicated that, at lower oxidant dosages (total residual oxidant (TRO) equivalent = 0.1 mg/l Cl2), chlorine dioxide had a better disinfection effect than chlorine and ozone. The performance of oxidizing biocides at pilot scale, operating at assorted conditions, showed that for the disinfectants tested, ozone could remove 95 % bioactivity of total number of bacteria and algae followed by chlorine dioxide at 85%, while conventional chlorine dosing only gave 60% reduction in bioactivities. Test results of GAC bio-filter showed that around 70 % removal of total organic carbon in the seawater feed was achieved and was effective in keeping the microbial growth to a minimum. The measured results from this study enable designers of seawater cooling towers to manage the biofouling problems when such cooling towers are extrapolated to a pilot scale.

  5. Fire behaviour of cooling tower packing; Brandverhalten von Kuehlturmeinbauten

    Energy Technology Data Exchange (ETDEWEB)

    Mattausch, Tim [DMT GmbH und Co. KG, Dortmund (Germany). Fachstelle fuer Brandschutz

    2013-10-01

    The rapid burning down of the cooling tower of the shutdown power plant in Schwandorf revealed the potential of a total loss of a cooling tower in case of fire. VGB ordered a research project in order to obtain more knowledge about the fire risk of cooling tower packing currently applied. Depending on kind and age of the plastics used, the results of these tests manifest a big variation of the fire behaviour. For the applications of plastics, it is essential to determine and to adhere to organisational fire protection measures. (orig.)

  6. Sicilian Castles and Coastal Towers

    Directory of Open Access Journals (Sweden)

    Kirk Scott

    2017-11-01

    Full Text Available While much attention has been paid to the development of castles as the hallmark architectural symbol of the Middle Ages, less attention has been given to the changes in European defensive strategies that occurred between the 15th and 17th centuries. It was at this time when the modern nations of Europe began to take form, as sea-based trade between distant nations took precedence over land-based trade routes. This paper examines how this transformation manifested in the defensive structures of Sicily, Italy, where the hilltop castles of the Middle Ages gradually gave way to a more cohesive network of coastal towers around the island. Putting this transition in its historical context, presenting an anthropological model from which to view this transition, and using geospatial methods to track these changes, the results of this study indicate that as defensive towers began to dominate the Sicilian coast around the 16th century, their command over the environment was no greater than that of the feudal castles which were still in use. Yet, unlike the castles of feudal lords, these towers represented an island-wide system of defense and the beginning of an adherence to a more centralized power structure then seen previously.

  7. A Dimensioning Methodology for a Natural Draft Wet Cooling Tower

    Directory of Open Access Journals (Sweden)

    Ioana Opriș

    2017-05-01

    Full Text Available The paper proposes a methodology for the dimensioning of a natural draft wet cooling tower. The main geometrical dimensions depend on the packing type, the cooling and the weather conditions. The study is based on splitting the tower in three main zones: the spray and packing zone, the rain zone and the natural draft zone. The methodology is developed on modular bases, by using block-modules both for the three main zones of the cooling tower and for the inlet/outlet air properties. It is useful in explaining to the students the complex physical phenomena within the cooling tower but also for the development of a computer program to be used in engineering, management and education.

  8. Research on Condition Assessment Method of Transmission Tower Under the Action of Strong Wind

    Science.gov (United States)

    Huang, Ren-mou; An, Li-qiang; Zhang, Rong-lun; Wu, Jiong; Liang, Ya-feng

    2018-03-01

    Transmission towers are often subjected to the external damage of severe weather like strong wind and so on, which may cause the collapse due to the yield and fracture of the tower material. Aiming this issue, an assessment method was proposed in this paper to assess the operation condition of transmission towers under strong wind. With a reasonable assess index system established firstly, then the internal force of the tower material was solved and its stability was determined through the mechanical analysis of the transmission tower finite element model. Meanwhile, the condition risk level of the tower was finally determined by considering the difference among the influences of other factors like corrosion and loose of members, slope on the transmission tower through the analytic hierarchy process. The assessment method was applied to assess the wind-induced collapse of towers in 110kV Bao Yi II line in Wenchang City, Hainan Province, of which the result proves the method can assess the condition of transmission tower under strong wind and of guiding significance for improving the windproof capability of transmission towers.

  9. A new tower with good p-rank meeting Zink’s bound

    DEFF Research Database (Denmark)

    Anbar Meidl, Nurdagül; Beelen, Peter; Nguyen, Nhut

    2017-01-01

    In this article we investigate the asymptotic p-rank of a new tower of function fields defined over cubic finite fields. Its limit meets Zink's bound, but the new feature of this tower is that its asymptotic p-rank for small cubic finite fields is much smaller than that of other cubic towers...

  10. One-year dynamic monitoring of a masonry tower

    Directory of Open Access Journals (Sweden)

    Guidobaldi Marco

    2015-01-01

    Full Text Available The paper presents some results of the continuous dynamic monitoring program carried out on the tallest historic tower in Mantua, Italy. This project follows an extensive diagnostic investigation aimed at assessing the structural condition of the tower after the Italian earthquakes of May 2012. A simple dynamic monitoring system was permanently installed in the upper part of the building and automatic modal identification was performed. The results allow to evaluate the effects of changing temperature on automatically identified natural frequencies, to verify the practical feasibility of damage detection methods based on natural frequencies shifts and provide clear evidence of the possible key role of continuous dynamic monitoring in the preventive conservation of historic towers.

  11. Lectures in Micro Meteorology

    DEFF Research Database (Denmark)

    Larsen, Søren Ejling

    This report contains the notes from my lectures on Micro scale meteorology at the Geophysics Department of the Niels Bohr Institute of Copenhagen University. In the period 1993-2012, I was responsible for this course at the University. At the start of the course, I decided that the text books...... available in meteorology at that time did not include enough of the special flavor of micro meteorology that characterized the work of the meteorology group at Risø (presently of the Institute of wind energy of the Danish Technical University). This work was focused on Boundary layer flows and turbulence...

  12. Potentially pathogenic amoeba-associated microorganisms in cooling towers and their control.

    Science.gov (United States)

    Pagnier, Isabelle; Merchat, Michèle; La Scola, Bernard

    2009-06-01

    Cooling towers provide a favorable environment for the proliferation of microorganisms. Cooling towers generate a biofilm and often aerosolize contaminated water, thereby increasing the risk of microorganism dissemination by human inhalation. This pathogen dissemination was first revealed by the epidemics of Legionnaires' disease that were directly related to the presence of cooling towers, and since then, the ecology of Legionella pneumophila has been well studied. Each country has specific standards regarding the acceptable amount of microorganisms in cooling tower systems. However, those standards typically only concern L. pneumophila, even though many other microorganisms can also be isolated from cooling towers, including protozoa, bacteria and viruses. Microbiological control of the cooling tower system can be principally achieved by chemical treatments and also by improving the system's construction. Several new treatments are being studied to improve the efficiency of disinfection. However, as most of these treatments continue to focus solely on L. pneumophila, reports of other types of pathogens continue to increase. Therefore, how their dissemination affects the human populous health should be addressed now.

  13. High-mechanical-strength single-pulse draw tower gratings

    Science.gov (United States)

    Rothhardt, Manfred W.; Chojetzki, Christoph; Mueller, Hans Rainer

    2004-11-01

    The inscription of fiber Bragg gratings during the drawing process is a very useful method to realize sensor arrays with high numbers of gratings and excellent mechanical strength and also type II gratings with high temperature stability. Results of single pulse grating arrays with numbers up to 100 and definite wavelengths and positions for sensor applications were achieved at 1550 nm and 830 nm using new photosensitive fibers developed in IPHT. Single pulse type I gratings at 1550 nm with more than 30% reflectivity were shown first time to our knowledge. The mechanical strength of this fiber with an Ormocer coating with those single pulse gratings is the same like standard telecom fibers. Weibull plots of fiber tests will be shown. At 830 nm we reached more than 10% reflectivity with single pulse writing during the fiber drawing in photosensitive fibers with less than 16 dB/km transmission loss. These gratings are useful for stress and vibration sensing applications. Type II gratings with reflectivity near 100% and smooth spectral shape and spectral width of about 1 nm are temperature stable up to 1200 K for short time. They are also realized in the fiber drawing process. These gratings are useful for temperature sensor applications.

  14. Industrial cooling tower design and operation in the moderate-continental climate conditions

    OpenAIRE

    Laković Mirjana S.; Banjac Miloš J.; Laković Slobodan V.; Jović Milica M.

    2016-01-01

    A large number of producers offer a wide choice of various types of industrial cooling towers. Usually, a proper choice of pre-fabricated cooling tower satisfies end-user needs. However, if there are specific end-user requirements, it is necessary to design cooling tower according to those requirements. For the adhesive factory located in southern region of Serbia, 350 kW mechanical draught wet cooling tower was designed and built. Dimensioning of the cooli...

  15. Natural-draught cooling tower of the Philippsburg-1 reactor

    International Nuclear Information System (INIS)

    Ernst, G.; Wurz, D.

    1983-01-01

    In spring 1980 a comprehensive research programm was carried out on the natural-draught cooling tower of the Philippsburg-1 reactor. The study was meant to synchronously acquire all parameters necessary for the evaluation of plant operation and cooling tower emissions. The study is subdivided into 8 sub-projects. Parts 1 to 7 that are included in this progress-of-work report describe experimental work and discuss the results. A critical analysis of measuring results proves that the values for operational behaviour and cooling tower emissions were duly anticipated. Even a very critical judgment of the results can exclude direct or indirect hazards for humans, animals and plants owing to cooling tower emissions. Sub-project 8 compares results from diffusion calculations (24 models) to results gained from experiments. The results of sub-project 8 will be published in a progress report to come. (orig.) [de

  16. Outcomes of the Tower Crane Technique with a 15-mm Trocar in Primary Spontaneous Pneumothorax

    Directory of Open Access Journals (Sweden)

    Yooyoung Chong

    2016-04-01

    Full Text Available Background: Video-assisted thoracoscopic surgery (VATS pulmonary wedge resection has emerged as the standard treatment for primary spontaneous pneumothorax. Recently, single-port VATS has been introduced and is now widely performed. This study aimed to evaluate the outcomes of the Tower crane technique as novel technique using a 15-mm trocar and anchoring suture in primary spontaneous pneumothorax. Methods: Patients who underwent single- port VATS wedge resection in Chungnam National University Hospital from April 2012 to March 2014 were enrolled. The medical records of the enrolled patients were reviewed retrospectively. Results: A total of 1,251 patients were diagnosed with pneumothorax during this period, 270 of whom underwent VATS wedge resection. Fifty-two of those operations were single-port VATS wedge resections for primary spontaneous pneumothorax performed by a single surgeon. The median age of the patients was 19.3±11.5 years old, and 43 of the patients were male. The median duration of chest tube drainage following the operation was 2.3±1.3 days, and mean postoperative hospital stay was 3.2±1.3 days. Prolonged air leakage for more than three days following the operation was observed in one patient. The mean duration of follow-up was 18.7±6.1 months, with a recurrence rate of 3.8%. Conclusion: The tower crane technique with a 15-mm trocar may be a promising treatment modality for patients presenting with primary spontaneous pneumothorax.

  17. Cancer in proximity to TV towers

    International Nuclear Information System (INIS)

    Hocking, B.; Gordon, I.; Hatfield, G.

    1996-01-01

    Full text: The effects of low level electro-magnetic fields on cancer development are controversial. There have been few epidemiological studies on the effects of radio-frequency radiation (RFR) and differing conclusions on possible detrimental health effects in humans (Goldsmith, Int. J Occ. and Env. Hlth, 1:47-57, 1995) (WHO, Env. Health Criteria 137). An unusual opportunity to assess possible risks further arose as cancer data (1972-1990) became available covering an area of North Sydney where three TV towers are located in a populated locality. An analysis of data was undertaken comparing cancer incidence and mortality in the three municipalities which immediately surround the TV towers compared to the adjacent three surrounding municipalities. Methods Data for the RFR sources on the towers was obtained (Dept. of Communications, Radio and TV Stations, 1994). The combined field strengths of the video and audio from the three towers and four channels at increasing distances were calculated (NCRP Report 119). Data from the NSW Cancer Registry on incidence, mortality and residence for 1972-1990 available via Healthwiz were extracted by municipality and for sex and age bands 0-14, 15-69 and 70+. Privacy reasons limit the availability of more refined data. The data were examined using a Poisson regression model (Frome EL, Biometrics, 39:665-74, 1983) with the numbers of cases or deaths regarded as Poisson random variables, whose mean is a product of the person years for the observation, and functions of the variables. The variables used were age categories, sex, calendar period (1972-78, 1979-84 and 1985-90), and area (inner 0-4 km and outer 4-12 km). To compare with the whole of NSW standardised incidence ratios and standardised mortality ratios were calculated. Confidence intervals were calculated using the 'exact' method (Liddell FDK, J. Epid. and Comm. Health, 38:85-88, 1984). Calculated field strengths are well below the limits prescribed in the Australian

  18. Research into spectra transformation of cooling tower droplet drift

    International Nuclear Information System (INIS)

    Mandrykin, G.P.

    1990-01-01

    Empirical droplet-diameter distributions in a cooling tower and outside are well approximated by the Rosin-Rammler-Bennet two-parameter function. Fractional efficiency of eliminators is also approximated by the above function fairly well. The design formulas proposed are universal and allow evaluation of droplet spectra transformation as well as the efficiency of measures for preventing droplet emissions from cooling towers both at the design and operation stages. Estimates of cooling tower droplet emissions calculated by the formulas suggested may be recommended as input data applied to the solution of environmental pollution problems and their assessment

  19. Investigation on Shielding Failure of a Novel 400 kV Composite tower

    DEFF Research Database (Denmark)

    Wang, Qian; Jahangiri, Tohid; Bak, Claus Leth

    2018-01-01

    In this paper, the lightning shielding performance of a newly-designed 400 kV double-circuit composite tower is investigated. Based on a revised EGM method, traditional shielding failure regions, located at both sides of a traditional tower is no longer a big issue for the fully composite tower......, due to its unusual ‘Y’ configuration. Instead, a new unprotected region exists in the tower center. The maximum lightning current that can lead to shielding failure and the shielding failure rate (SFR) of the new tower are calculated. To verify results from the revised EGM method, a scale model test...... is conducted. Spatial shielding failure probability around the tower is calculated based on ratio of discharge paths recorded in the test. Moreover, based on test results, the maximum shielding failure lightning currents are obtained. Analysis and results derived from the revised EGM method and scale model...

  20. Towards safe and economic seismic design of cooling towers of extreme height

    International Nuclear Information System (INIS)

    Kraetzig, W.B.; Meskouris, K.

    1979-01-01

    Nuclear power plants are being increasingly equipped with natural draught cooling towers of heights greater than 160 m. In many arid zones, where high natural draught cooling towers with dry cooling systems are being projected, wind loads are relativelly small while site seismicity is relatively high. Thus the ability of the tower to withstand earthquake induced forces governs its design. On the other hand, most reinforced concrete cooling towers of extreme height built so far were designed to withstand high wind loads and moderate earthquake loads. The effects of special structural measures for obtaining an economic design, such as the introduction of ring stiffened shells, have been studied mainly for those towers. In view of the previous aspects it is the purpose of this paper to analyze the effects of various structural measures and other parameters on the seismic response of such high cooling towers. (orig.)

  1. Statistical multi-model approach for performance assessment of cooling tower

    International Nuclear Information System (INIS)

    Pan, Tian-Hong; Shieh, Shyan-Shu; Jang, Shi-Shang; Tseng, Wen-Hung; Wu, Chan-Wei; Ou, Jenq-Jang

    2011-01-01

    This paper presents a data-driven model-based assessment strategy to investigate the performance of a cooling tower. In order to achieve this objective, the operations of a cooling tower are first characterized using a data-driven method, multiple models, which presents a set of local models in the format of linear equations. Satisfactory fuzzy c-mean clustering algorithm is used to classify operating data into several groups to build local models. The developed models are then applied to predict the performance of the system based on design input parameters provided by the manufacturer. The tower characteristics are also investigated using the proposed models via the effects of the water/air flow ratio. The predicted results tend to agree well with the calculated tower characteristics using actual measured operating data from an industrial plant. By comparison with the design characteristic curve provided by the manufacturer, the effectiveness of cooling tower can be obtained in the end. A case study conducted in a commercial plant demonstrates the validity of proposed approach. It should be noted that this is the first attempt to assess the cooling efficiency which is deviated from the original design value using operating data for an industrial scale process. Moreover, the evaluated process need not interrupt the normal operation of the cooling tower. This should be of particular interest in industrial applications.

  2. Wind-induced transmission tower foundation loads. A field study-design code comparison

    Energy Technology Data Exchange (ETDEWEB)

    Savory, E. [Department of Mechanical and Materials Engineering, University of Western Ontario, London, Ont. (Canada); Parke, G.A.R.; Disney, P.; Toy, N. [School of Engineering, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom)

    2008-06-15

    This paper presents a comparison between the wind-induced foundation loads measured on a type L6 transmission line tower during a field study in the UK and those computed using the UK Code of Practice for lattice tower and transmission line design (BS8100). In this work, the Code provisions have been generalised to give the wind-induced strain in each of the tower legs immediately above the foundation as a function of wind direction and wind speed at the top of the tower. The complete data set from the field monitoring has been decomposed to provide a similar formulation for comparison purposes. The analysis shows excellent agreement between the Code calculations and the measured results, within the overall accuracy of the field data. This indicates that, at least for the tower type examined here, the existing design Code provides a reliable transformation of the local wind speed at the top of the tower into tension and compression loads on the foundations. (author)

  3. Active tower damping and pitch balancing - design, simulation and field test

    Science.gov (United States)

    Duckwitz, Daniel; Shan, Martin

    2014-12-01

    The tower is one of the major components in wind turbines with a contribution to the cost of energy of 8 to 12% [1]. In this overview the load situation of the tower will be described in terms of sources of loads, load components and fatigue contribution. Then two load reduction control schemes are described along with simulation and field test results. Pitch Balancing is described as a method to reduce aerodynamic asymmetry and the resulting fatigue loads. Active Tower Damping is reducing the tower oscillations by applying appropiate pitch angle changes. A field test was conducted on an Areva M5000 wind turbine.

  4. Detection of Excessive Wind Turbine Tower Oscillations Fore-Aft and Sideways

    DEFF Research Database (Denmark)

    Knudsen, Torben; Bak, Thomas; Tabatabaeipour, Seyed Mojtaba

    2012-01-01

    Fatigue loads are important for the overall cost of energy from a wind turbine. Loading on the tower is one of the more important loads, as the tower is an expensive component. Consequently, it is important to detect tower loads, which are larger than necessary. This paper deals with both fore......-aft and sideways tower oscillations. Methods for estimation of the amplitude and detection of the cause for vibrations are developed. Good results are demonstrated for real data from modern multi mega watt turbines. It is shown that large oscillations can be detected and that the method can discriminate between...... wind turbulence and unbalanced rotor....

  5. Cooling tower water conditioning study. [using ozone

    Science.gov (United States)

    Humphrey, M. F.; French, K. R.

    1979-01-01

    Successful elimination of cooling tower treatment chemicals was demonstrated. Three towers functioned for long periods of time with ozone as the only treatment for the water. The water in the systems was reused as much as 30 times (cycles of concentration) without deleterious effects to the heat exchangers. Actual system blow-down was eliminated and the only makeup water added was that required to replace the evaporation and mist entrainment losses. Minimum water savings alone are approximately 75.1 1/kg/year. Cost estimates indicate that a savings of 55 percent was obtained on the systems using ozone. A major problem experienced in the use of ozone for cooling tower applications was the difficulty of accurate concentration measurements. The ability to control the operational characteristics relies on easily and accurately determined concentration levels. Present methods of detection are subject to inaccuracies because of interfering materials and the rapid destruction of the ozone.

  6. Fatigue Analysis of a Mono-Tower Platform

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Sørensen, John Dalsgaard; Brincker, Rune

    In this paper, a fatigue reliability analysis of a Mono-tower platform is presented. The failure mode, fatigue failure in the butt welds, is investigated with two different models. The one with the fatigue strength expressed through SN relations, the other with the fatigue strength expressed thro...... of the natural period, damping ratio, current, stress Spectrum and parameters describing the fatigue strength. Further, soil damping is shown to be significant for the Mono-tower.......In this paper, a fatigue reliability analysis of a Mono-tower platform is presented. The failure mode, fatigue failure in the butt welds, is investigated with two different models. The one with the fatigue strength expressed through SN relations, the other with the fatigue strength expressed...... through linear-elastic fracture mechanics (LEFM). In determining the cumulative fatigue damage, Palmgren-Miner's rule is applied. Element reliability as well as systems reliability is estimated using first-order reliability methods (FORM). The sensitivity of the systems reliability to various parameters...

  7. Operating manual for the Tower Shielding Facility

    International Nuclear Information System (INIS)

    1985-12-01

    This manual provides information necessary to operate and perform maintenance on the reactor systems and all equipment or systems which can affect their operation or the safety of personnel at the Tower Shielding Facility. The first four chapters consist of introductory and descriptive material of benefit to personnel in training, the qualifications required for training, the responsibilities of the personnel in the organization, and the procedures for reviewing proposed experiments. Chapter 8, Emergency Procedures, is also a necessary part of the indoctrination of personnel. The procedures for operation of the Tower Shielding Reactor (TSR-II), its water cooling system, and the main tower hoists are outlined in Chapters 5, 6, and 7. The Technical Specification surveillance requirements for the TSR-II are summarized in Chapter 9. The maintenance and calibration schedule is spelled out in Chapter 10. The procedures for assembly and disassembly of the TSR-II are outlined in Chapter 11

  8. The solar two power tower project

    International Nuclear Information System (INIS)

    Chavez, J.M.; Klimas, P.C.; Laquil, P. de III; Skowronski, M.

    1993-01-01

    A consortium of United States utility concerns led by Southern California Edison Company (SCE) has begun a cooperative project with the U.S. Department of Energy (DOE) and industry to convert the 10-MWe Solar One Tower Pilot Plant to molten nitrate salt technology. Successful operation of the convert plant to be called Solar Two, will reduce the economic risks in building the initial commercial power tower projects and accelerate the commercial acceptance of this promising renewable energy technology. In a molten salt power tower plant, sunlight is concentrated by a field of sun-tracking mirrors, called heliostats, onto a centrally located receiver, atop a tower. Molten salt is heated in the receiver and stored until it is needed to generate steam to power a conventional turbine generator. Joining the SCE and DOE in sponsoring in sponsoring this project are the following organizations: Los Alamos department of Water Power, Idaho Power Company, PacifiCorp, Pacific Gas and Electric Company, Sacramento Municipal Utility District, Arizona Public Service Company, Salt River Project, City of Pasadena, California Energy Commission, Electric Power Research Institute, South Coast Air Quality Commission, Electric Power research Institute, South Coast Air Quality Management District, and Bechtel Corporation. The Solar Two project will convert the Solar One heat transfer system from a water/steam type to molten nitrate salt by replacing the water/steam receiver and oil/rock thermal storage system with a nitrate salt receiver, salt thermal storage, and steam generator. The estimate cost of Solar Two, including 3-year test period, is 48.5 millions. The plant will be on line in early 1995. (authors)

  9. Subring Depth, Frobenius Extensions, and Towers

    Directory of Open Access Journals (Sweden)

    Lars Kadison

    2012-01-01

    Full Text Available The minimum depth d(B,A of a subring B⊆A introduced in the work of Boltje, Danz and Külshammer (2011 is studied and compared with the tower depth of a Frobenius extension. We show that d(B,A < ∞ if A is a finite-dimensional algebra and Be has finite representation type. Some conditions in terms of depth and QF property are given that ensure that the modular function of a Hopf algebra restricts to the modular function of a Hopf subalgebra. If A⊇B is a QF extension, minimum left and right even subring depths are shown to coincide. If A⊇B is a Frobenius extension with surjective Frobenius, homomorphism, its subring depth is shown to coincide with its tower depth. Formulas for the ring, module, Frobenius and Temperley-Lieb structures are noted for the tower over a Frobenius extension in its realization as tensor powers. A depth 3 QF extension is embedded in a depth 2 QF extension; in turn certain depth n extensions embed in depth 3 extensions if they are Frobenius extensions or other special ring extensions with ring structures on their relative Hochschild bar resolution groups.

  10. Virtual and remote control tower research, design, development and validation

    CERN Document Server

    2016-01-01

    The interdisciplinary research and development work carried out in the last ten years which is presented in this book aimed at replacing the conventional airport control tower by a new “remote tower operation” work environment (RTO) which should enhance work efficiency and safety and reduce costs. This revolutionary human–system interface allows for remote aerodrome traffic control without a physical tower building and enables the establishment of remote airport traffic control centers (RTC) of which each may serve several airports from a central location.

  11. Sensor Placement For Structural Monitoring of Transmission Line Towers

    Directory of Open Access Journals (Sweden)

    Benny eRaphael

    2015-11-01

    Full Text Available Transmission line towers are usually analyzed using linear elastic idealized truss models. Due to the assumptions used in the analysis, there are discrepancies between the actual results obtained from full scale prototype testing and the analytical results. Therefore, design engineers are interested in assessing the actual stress levels in transmission line towers. Since it is costly to place sensors on every member of a tower structure, the best locations for sensors need to be carefully selected. This study evaluates a methodology for sensor placement in transmission line towers. The objective is to find optimal locations for sensors such that the real behavior of the structure can be explained from measurements. The methodology is based on the concepts of entropy and model falsification. Sensor locations are selected based on maximum entropy such that there is maximum separation between model instances that represent different possible combinations of parameter values which have uncertainties. The performance of the proposed algorithm is compared to that of an intuitive method in which sensor locations are selected where the forces are maximum. A typical 220 kV transmission tower is taken as case study in this paper. It is shown that the intuitive method results in much higher number of non-separable models compared to the optimal sensor placement algorithm. Thus the intuitive method results in poor identification of the system.

  12. Evaluation of Offshore Wind Turbine Tower Dynamics with Numerical Analysis

    Directory of Open Access Journals (Sweden)

    Begum Yurdanur Dagli

    2018-01-01

    Full Text Available A dynamic behaviour of a cylindirical wind tower with variable cross section is investigated under environmental and earthquake forces. The ground acceleration term is represented by a simple cosine function to investigate both normal and parallel components of the earthquake motions located near ground surface. The function of earthquake force is simplified to apply Rayleigh’s energy method. Wind forces acting on above the water level and wave forces acting on below this level are utilized in computations considering earthquake effect for entire structure. The wind force is divided into two groups: the force acting on the tower and the forces acting on the rotor nacelle assembly (RNA. The drag and the inertial wave forces are calculated with water particle velocities and accelerations due to linear wave theory. The resulting hydrodynamic wave force on the tower in an unsteady viscous flow is determined using the Morison equation. The displacement function of the physical system in which dynamic analysis is performed by Rayleigh’s energy method is obtained by the single degree of freedom (SDOF model. The equation of motion is solved by the fourth-order Runge–Kutta method. The two-way FSI (fluid-structure interaction technique was used to determine the accuracy of the numerical analysis. The results of computational fluid dynamics and structural mechanics are coupled in FSI analysis by using ANSYS software. Time-varying lateral displacements and the first natural frequency values which are obtained from Rayleigh’s energy method and FSI technique are compared. The results are presented by graphs. It is observed from these graphs that the Rayleigh model can be an alternative way at the prelimanary stage of the structural analysis with acceptable accuracy.

  13. Concept of CFD model of natural draft wet-cooling tower flow

    Directory of Open Access Journals (Sweden)

    Hyhlík T.

    2014-03-01

    Full Text Available The article deals with the development of CFD model of natural draft wet-cooling tower flow. The physical phenomena taking place within a natural draft wet cooling tower are described by the system of conservation law equations along with additional equations. The heat and mass transfer in the counterflow wet-cooling tower fill are described by model [1] which is based on the system of ordinary differential equations. Utilization of model [1] of the fill allows us to apply commonly measured fill characteristics as shown by [2].The boundary value problem resulting from the fill model is solved separately. The system of conservation law equations is interlinked with the system of ordinary differential equations describing the phenomena occurring in the counterflow wet-cooling tower fill via heat and mass sources and via boundary conditions. The concept of numerical solution is presented for the quasi one dimensional model of natural draft wet-cooling tower flow. The simulation results are shown.

  14. Meteorology/Oceanography Help - Naval Oceanography Portal

    Science.gov (United States)

    section Advanced Search... Sections Home Time Earth Orientation Astronomy Meteorology Oceanography Ice You are here: Home › Help › Meteorology/Oceanography Help USNO Logo USNO Info Meteorology/Oceanography Help Send an e-mail regarding meteorology or oceanography products. Privacy Advisory Your E-Mail

  15. Cell Towers and Songbirds

    Science.gov (United States)

    Klosterman, Michelle; Mesa, Jennifer; Milton, Katie

    2009-01-01

    This article describes how our common addiction to cell phones was used to launch a discussion about their use, impacts on the environment, and connections to issues of civic concern. By encouraging middle school science students to adopt the perspectives of special-interest groups debating communication tower restrictions designed to protect…

  16. Disinfection of bacterial biofilms in pilot-scale cooling tower systems.

    Science.gov (United States)

    Liu, Yang; Zhang, Wei; Sileika, Tadas; Warta, Richard; Cianciotto, Nicholas P; Packman, Aaron I

    2011-04-01

    The impact of continuous chlorination and periodic glutaraldehyde treatment on planktonic and biofilm microbial communities was evaluated in pilot-scale cooling towers operated continuously for 3 months. The system was operated at a flow rate of 10,080 l day(-1). Experiments were performed with a well-defined microbial consortium containing three heterotrophic bacteria: Pseudomonas aeruginosa, Klebsiella pneumoniae and Flavobacterium sp. The persistence of each species was monitored in the recirculating cooling water loop and in biofilms on steel and PVC coupons in the cooling tower basin. The observed bacterial colonization in cooling towers did not follow trends in growth rates observed under batch conditions and, instead, reflected differences in the ability of each organism to remain attached and form biofilms under the high-through flow conditions in cooling towers. Flavobacterium was the dominant organism in the community, while P. aeruginosa and K. pneumoniae did not attach well to either PVC or steel coupons in cooling towers and were not able to persist in biofilms. As a result, the much greater ability of Flavobacterium to adhere to surfaces protected it from disinfection, whereas P. aeruginosa and K. pneumoniae were subject to rapid disinfection in the planktonic state.

  17. Improvement of coal focus and cooling towers of COFRENTES NPP

    International Nuclear Information System (INIS)

    Martinez, I.; Bogh, P.

    1998-01-01

    Cofrentes Nuclear Power Plant is performing a improving program of its cooling towers based on the filling revamping and cooling water circuit improvement. Furthermore, and as consequence of the acquired experience on cooling towers due to the mentioned program, Cofrentes NPP has decided to follow up with this project from a different point of view based on the thermal-hydraulic optimization of the cooling process inside the towers. This program, which is going to be carried out by Cofrentes NPP, Iberinco and Energy Planning and Power Generation (EPPG) provides an improvement on the thermal profile and of the draught inside the cooling towers by improving the water distribution in the towers active area. In order to perform such a program is needed to fulfill a test program to assure a guaranteed performance gain. In this way, Iberinco is developing a test procedure which improves the results which are obtained with the present standards used commonly by the industry. As a consequence of this program, Cofrentes is expecting to obtain a gain of 5 to 8 MWe with a revenue period of 4 to 5 months, results validated in another foreigner Plant which have developed a similar program. (Author)

  18. Design of SMART waste heat removal dry cooling tower using solar energy

    International Nuclear Information System (INIS)

    Choi, Yong Jae; Jeong, Yong Hoon

    2014-01-01

    The 85% of cooling system are once-through cooling system and closed cycle wet cooling system. However, many countries are trying to reduce the power plant water requirement due to the water shortage and water pollution. Dry cooling system is investigated for water saving advantage. There are two dry cooling system which are direct and indirect cooling system. In direct type, turbine exhaust is directly cooled by air-cooled condenser. In indirect system, turbine steam is cooled by recirculating intermediate cooling water loop, then the loop is cooled by air-cooled heat exchanger in cooling tower. In this paper, the purpose is to remove SMART waste heat, 200MW by using newly designed tower. The possibility of enhancing cooling performance by solar energy is analyzed. The simple cooling tower and solar energy cooling tower are presented and two design should meet the purpose of removing SMART waste heat, 200MW. In first design, when tower diameter is 70m, the height of tower should be 360m high. In second design, the chimney height decrease from 360m to 180m as collector radius increase from 100m to 500m due to collector temperature enhancement by solar energy, To analyze solar cooling tower further, consideration of solar energy performance at night should be analyzed

  19. Design of SMART waste heat removal dry cooling tower using solar energy

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Yong Jae; Jeong, Yong Hoon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2014-10-15

    The 85% of cooling system are once-through cooling system and closed cycle wet cooling system. However, many countries are trying to reduce the power plant water requirement due to the water shortage and water pollution. Dry cooling system is investigated for water saving advantage. There are two dry cooling system which are direct and indirect cooling system. In direct type, turbine exhaust is directly cooled by air-cooled condenser. In indirect system, turbine steam is cooled by recirculating intermediate cooling water loop, then the loop is cooled by air-cooled heat exchanger in cooling tower. In this paper, the purpose is to remove SMART waste heat, 200MW by using newly designed tower. The possibility of enhancing cooling performance by solar energy is analyzed. The simple cooling tower and solar energy cooling tower are presented and two design should meet the purpose of removing SMART waste heat, 200MW. In first design, when tower diameter is 70m, the height of tower should be 360m high. In second design, the chimney height decrease from 360m to 180m as collector radius increase from 100m to 500m due to collector temperature enhancement by solar energy, To analyze solar cooling tower further, consideration of solar energy performance at night should be analyzed.

  20. Allegheny County Cell Tower Points

    Data.gov (United States)

    Allegheny County / City of Pittsburgh / Western PA Regional Data Center — This dataset portrays cell tower locations as points in Allegheny County. The dataset is based on outbuilding codes in the Property Assessment Parcel Database used...

  1. 45-FOOT HIGH DROP TOWER

    Data.gov (United States)

    Federal Laboratory Consortium — The Drop Tower is used to simulate and measure the impact shocks that are exerted on parachute loads when they hit the ground. It is also used for HSL static lift to...

  2. KM3NeT tower data acquisition and data transport electronics

    Science.gov (United States)

    Nicolau, C. A.; Ameli, F.; Biagioni, A.; Capone, A.; Frezza, O.; Lonardo, A.; Masullo, R.; Mollo, C. M.; Orlando, A.; Simeone, F.; Vicini, P.

    2016-04-01

    In the framework of the KM3Net European project, the production stage of a large volume underwater neutrino telescope has started. The forthcoming installation includes 8 towers and 24 strings, that will be installed 100 km off-shore Capo Passero (Italy) at 3500 m depth. The KM3NeT tower, whose layout is strongly based on the NEMO Phase-2 prototype tower deployed in March 2013, has been re-engineered and partially re-designed in order to optimize production costs, power consumption, and usability. This contribution gives a description of the main electronics, including front-end, data transport and clock distribution system, of the KM3NeT tower detection unit.

  3. Modeling of existing cooling towers in ASPEN PLUS using an equilibrium stage method

    International Nuclear Information System (INIS)

    Queiroz, João A.; Rodrigues, Vitor M.S.; Matos, Henrique A.; Martins, F.G.

    2012-01-01

    Highlights: ► Simulation of cooling tower performance under different operating conditions. ► Cooling tower performance is simulated using ASPEN PLUS. ► Levenberg–Marquardt method used to adjust model parameters. ► Air and water outlet temperatures are in good accordance with experimental data. - Abstract: Simulation of cooling tower performance considering operating conditions away from design is typically based on the geometrical parameters provided by the cooling tower vendor, which are often unavailable or outdated. In this paper a different approach for cooling tower modeling based on equilibrium stages and Murphree efficiencies to describe heat and mass transfer is presented. This approach is validated with published data and with data collected from an industrial application. Cooling tower performance is simulated using ASPEN PLUS. Murphree stage efficiency values for the process simulator model were optimized by minimizing the squared difference between the experimental and calculated data using the Levenberg–Marquardt method. The minimization algorithm was implemented in Microsoft Excel with Visual Basic for Applications, integrated with the process simulator (ASPEN PLUS) using Aspen Simulation Workbook. The simulated cooling tower air and water outlet temperatures are in good accordance with experimental data when applying only the outlet water temperature to calibrate the model. The methodology is accurate for simulating cooling towers at different operational conditions.

  4. Reducing water consumption of an industrial plant cooling unit using hybrid cooling tower

    International Nuclear Information System (INIS)

    Rezaei, Ebrahim; Shafiei, Sirous; Abdollahnezhad, Aydin

    2010-01-01

    Water consumption is an important problem in dry zones and poor water supply areas. For these areas use of a combination of wet and dry cooling towers (hybrid cooling) has been suggested in order to reduce water consumption. In this work, wet and dry sections of a hybrid cooling tower for the estimation of water loss was modeled. A computer code was also written to simulate such hybrid cooling tower. To test the result of this simulation, a pilot hybrid tower containing a wet tower and 12 compact air cooled heat exchangers was designed and constructed. Pilot data were compared with simulation data and a correction factor was added to the simulation. Ensuring that the simulation represents the actual data, it was applied to a real industrial case and the effect of using a dry tower on water loss reduction of this plant cooling unit was investigated. Finally feasibility study was carried out to choose the best operating conditions for the hybrid cooling tower configuration proposed for this cooling unit.

  5. A test of Newton's Law of Gravity using the BREN Tower, Nevada

    International Nuclear Information System (INIS)

    Kasameyer, P.; Thomas, J.; Fackler, O.; Mugge, M.; Kammeraad, J.; Millett, M.; Harris, B.; Felske, D.

    1989-01-01

    We predicted gravity values on a tower by upward continuing an extensive set of surface data in order to test the 1/r 2 dependence of Newton's Law of Universal Gravitation. We measured gravity at 12 heights up to 454 m on a tower at the Nevada Test Site, and at 91 locations on the surface of the earth within 2.5 kilometers of the tower. These data have been combined with 60,000 surface gravity measurements within 300 kilometers of the tower and have been used to predict the gravitational field on the tower via a solution of Laplace's equation. A discrepancy between the observed gravity values and the prediction could suggest a breakdown of Newtonian Gravity, but we observe none. Our preliminary results are consistent with the Newtonian hypothesis to within 93 +- 95 μgals at the top of the tower, a result which conflicts with the previously reported 500 μgal non-Newtonian signal seen at 562 meters above the earth. 24 refs., 2 figs

  6. Tornado frequency in the USA - meteorological and non-meteorological factors of a downward trend

    Directory of Open Access Journals (Sweden)

    Mihajlović Jovan

    2015-01-01

    Full Text Available Citing numerical simulations, climate alarmists believe that global warming will lead to more frequent and more intensive tornadoes. Considering temperature increase data in the contiguous USA, this study has investigated the trend of strong tornadoes in F3+ category in the 1954-2012 period. Statistically significant decrease of tornadoes per year at an average rate of 0.44 has been recorded, that is, 4.4 tornadoes per decade. Tornado increase has been recorded with F0 and F1 categories and the cause of this increase lies in meteorological and non-meteorological factors. By using upper and lower standard deviation values, the stages of tornado activity have been singled out. The 1957-1974 period may be considered as an active stage and the 1978-2009 period as an inactive stage. Upward trend of air temperature increase does not correspond with the downward trend of the number of F3+ tornado category, while the correlation coefficient between these two variables is R = −0.14. This fact does not correspond with the simulation results and output data of various numerical models anticipating an increase in the number and intensity of tornado events in the conditions of surface air temperature growth.

  7. Cellular Phone Towers, File name = CELLTOWERS Contains point file of cell towers and an inclomplete poly cadastral layer of properties with cell towers. http://www.harfordcountymd.gov/gis/Index.cfm, Published in 2011, 1:1200 (1in=100ft) scale, Harford County Government.

    Data.gov (United States)

    NSGIC Local Govt | GIS Inventory — Cellular Phone Towers dataset current as of 2011. File name = CELLTOWERS Contains point file of cell towers and an inclomplete poly cadastral layer of properties...

  8. Role of bacterial adhesion in the microbial ecology of biofilms in cooling tower systems.

    Science.gov (United States)

    Liu, Yang; Zhang, Wei; Sileika, Tadas; Warta, Richard; Cianciotto, Nicholas P; Packman, Aaron

    2009-01-01

    The fate of the three heterotrophic biofilm forming bacteria, Pseudomonas aeruginosa, Klebsiella pneumoniae and Flavobacterium sp. in pilot scale cooling towers was evaluated both by observing the persistence of each species in the recirculating water and the formation of biofilms on steel coupons placed in each cooling tower water reservoir. Two different cooling tower experiments were performed: a short-term study (6 days) to observe the initial bacterial colonization of the cooling tower, and a long-term study (3 months) to observe the ecological dynamics with repeated introduction of the test strains. An additional set of batch experiments (6 days) was carried out to evaluate the adhesion of each strain to steel surfaces under similar conditions to those found in the cooling tower experiments. Substantial differences were observed in the microbial communities that developed in the batch systems and cooling towers. P. aeruginosa showed a low degree of adherence to steel surfaces both in batch and in the cooling towers, but grew much faster than K. pneumoniae and Flavobacterium in mixed-species biofilms and ultimately became the dominant organism in the closed batch systems. However, the low degree of adherence caused P. aeruginosa to be rapidly washed out of the open cooling tower systems, and Flavobacterium became the dominant microorganism in the cooling towers in both the short-term and long-term experiments. These results indicate that adhesion, retention and growth on solid surfaces play important roles in the bacterial community that develops in cooling tower systems.

  9. Meteorology and atomic energy

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    The science of meteorology is useful in providing information that will be of assistance in the choice of favorable plant locations and in the evaluation of significant relations between meteorology and the design, construction, and operation of plant and facilities, especially those from which radioactive or toxic products could be released to the atmosphere. Under a continuing contract with the Atomic Energy Commission, the Weather Bureau has carried out this study. Some of the meteorological techniques that are available are summarized, and their applications to the possible atmospheric pollution deriving from the use of atomic energy are described. Methods and suggestions for the collection, analysis, and use of meteorological data are presented. Separate abstracts are included of 12 chapters in this publication for inclusion in the Energy Data Base

  10. 78 FR 17183 - Information Collection: Grey Towers Visitor Comment Card

    Science.gov (United States)

    2013-03-20

    ... DEPARTMENT OF AGRICULTURE Forest Service Information Collection: Grey Towers Visitor Comment Card... request: (1) An extension from the Office of Management and Budget; and (2) to merge the currently approved information collection 0596- 0222, ``Grey Towers Visitor Comment Card'' with 0596-0226, ``Forest...

  11. Legionella species colonization in cooling towers: risk factors and assessment of control measures.

    Science.gov (United States)

    Mouchtouri, Varvara A; Goutziana, Georgia; Kremastinou, Jenny; Hadjichristodoulou, Christos

    2010-02-01

    Cooling towers can be colonized by Legionella spp, and inhalation of aerosols generated by their operation may cause Legionnaires' disease in susceptible hosts. Environmental investigations of Legionnaires' disease outbreaks linked with cooling towers have revealed poorly maintained systems, lack of control measures, and failure of system equipment. The purpose of this study was to identify Legionella-contaminated cooling towers, identify risk factors for contamination, and assess the effectiveness of control measures. A total of 96 cooling towers of public buildings were registered and inspected, and 130 samples were collected and microbiologically tested. Microbiological test results were associated with characteristics of cooling towers, water samples, inspection results, and maintenance practices. Of the total 96 cooling towers examined, 47 (48.9%) were colonized by Legionella spp, and 22 (22.9%) required remedial action. A total of 65 samples (50.0%) were positive (> or = 500 cfu L(-1)), and 30 (23%) were heavily contaminated (> or = 10(4) cfu L(-1)). Of the 69 isolates identified, 55 strains (79.7.%) were L pneumophila. Legionella colonization was positively associated with the absence of training on Legionella control (relative risk [RR] = 1.66; P = .02), absence of regular Legionella testing (RR = 2.07: P = .002), absence of sunlight protection (RR = 1.63: P = .02), with samples in which the free residual chlorine level in the water sample was cooling towers (median, 17 years; interquartile range [IQR] =5.0 to 26.0 years) compared with noncolonized cooling towers (median age, 6 years; IQR =1.0 to 13.5 years). After the 22 legionellae-positive cooling towers were disinfected with chlorine, 2 (9%) of them remained positive for Legionella spp with a concentration > or = 1000 cfu L(-1). Cooling towers can be heavily colonized by Legionella spp and thus present a potential risk for infection. This study demonstrates the importance of a risk assessment and

  12. Constraining CO2 tower measurements in an inhomogeneous area with anthropogenic emissions using a combination of car-mounted instrument campaigns, aircraft profiles, transport modeling and neural networks

    Science.gov (United States)

    Schmidt, A.; Rella, C.; Conley, S. A.; Goeckede, M.; Law, B. E.

    2013-12-01

    The NOAA CO2 observation network in Oregon has been enhanced by 3 new towers in 2012. The tallest tower in the network (270 m), located in Silverton in the Willamette Valley is affected by anthropogenic emissions from Oregon's busiest traffic routes and urban centers. In summer 2012, we conducted a measurement campaign using a car-mounted PICARRO CRDS CO2/CO analyzer. Over 3 days, the instrument was driven over 1000 miles throughout the northwestern portion of Oregon measuring the CO/ CO2 ratios on main highways, back roads in forests, agricultural sites, and Oregon's biggest urban centers. By geospatial analyses we obtained ratios of CO/ CO2 over distinct land cover types divided into 10 classes represented in the study area. Using the coupled WRF-STILT transport model we calculated the footprints of nearby CO/ CO2 observation towers for the corresponding days of mobile road measurements. Spatiotemporally assigned source areas in combination with the land use classification were then used to calculate specific ratios of CO (anthropogenic origins) and CO2 to separate the anthropogenic portion of CO2 from the mixing ratio time series measured at the tower in Silverton. The WRF modeled boundary layer heights used in out study showed some differences compared to the boundary layer heights derived from profile data of wind, temperature, and humidity measured with an airplane in August, September, and November 2012, repeatedly over 5 tower locations. A Bayesian Regularized Artificial Neural Network (BRANN) was used to correct the boundary layer height calculated with WRF with a temporal resolution of 20 minutes and a horizontal resolution of 4 km. For that purpose the BRANN was trained using height profile data from the flight campaigns and spatiotemporally corresponding meteorological data from WRF. Our analyses provide information needed to run inverse modeling of CO2 exchange in an area that is affected by sources that cannot easily be considered by biospheric models

  13. Trends, Opportunities, and Challenges for Tall Wind Turbine and Tower Technologies

    Energy Technology Data Exchange (ETDEWEB)

    Lantz, Eric; Roberts, Owen; Dykes, Katherine

    2017-06-28

    This presentation summarizes recent analysis focused on characterizing the opportunity for Tall Wind technologies generally and for tall tower technologies specifically. It seeks to illuminate and explain the concept of Tall Wind, its impact on the wind industry to date, and the potential value of Tall Wind in the future. It also explores the conditions and locations under which the impacts of Tall Wind offer the most significant potential to increase wind technology performance. In addition, it seeks to examine the status of tall tower technology as a key sub-component of Tall Wind, focusing on the potential for continued innovation in tubular steel wind turbine towers and the status and potential for a select set of alternative tall tower technologies.

  14. KM3NeT tower data acquisition and data transport electronics

    Directory of Open Access Journals (Sweden)

    Nicolau C.A.

    2016-01-01

    Full Text Available In the framework of the KM3Net European project, the production stage of a large volume underwater neutrino telescope has started. The forthcoming installation includes 8 towers and 24 strings, that will be installed 100 km off-shore Capo Passero (Italy at 3500 m depth. The KM3NeT tower, whose layout is strongly based on the NEMO Phase-2 prototype tower deployed in March 2013, has been re-engineered and partially re-designed in order to optimize production costs, power consumption, and usability. This contribution gives a description of the main electronics, including front-end, data transport and clock distribution system, of the KM3NeT tower detection unit.

  15. Reducing the risk of Legionnaires' disease associated with cooling towers

    Energy Technology Data Exchange (ETDEWEB)

    Freije, M.R. [HC Information Resources Inc., Carlsbad, CA (United States)

    2008-08-15

    To reduce the health and legal risks associated with Legionnaires' disease, facility managers should take steps to minimize Legionella bacteria in plumbing systems, open industrial equipment, water features, cooling towers, and other aerosolizing water systems. The risk of Legionnaires' disease associated with cooling towers can be reduced by controlling Legionella bacteria in cooling water and preventing transmission of the bacteria from towers to people. This paper presents nine reasonable ways to accomplish these goals. (orig.)

  16. Meteorological instrumentation for nuclear facilities

    International Nuclear Information System (INIS)

    Costa, A.C.L. da.

    1983-01-01

    The main requirements of regulatory agencies, concerning the meteorological instrumentation needed for the licensing of nuclear facilities are discussed. A description is made of the operational principles of sensors for the various meteorological parameters and associated electronic systems. An analysis of the problems associated with grounding of a typical meteorological station is presented. (Author) [pt

  17. INTEGRATED TWIN TOWERS DAN ISLAMISASI ILMU

    Directory of Open Access Journals (Sweden)

    Syaifuddin Syaifuddin

    2013-05-01

    Full Text Available This paper shows some idea as follows: First, integrated design of the Twin Towers as the changing action from IAIN to UIN Sunan Ampel. The religion and general knowledge’s position of Twin Towers’ integrated design is not mixed into one, but it works individually, and at the certain time are united in mutual dialogue. Second, Islamize design is done in order to criticize the general knowledge which has western sources and are secular, materialistic, and individualistic. In the process to Islamize the knowledge, Islamic knowledge tries to intervene the general knowledge in order to filter it so the knowledge will be Islamized. Consequently, to Islamize knowledge is to give an Islamic concept into general knowledge. Third, there are the similarities and differences between integrated design knowledge based on Islamic knowledge and integrated Twin Towers. The difference is in its epistemology process. The similarity is in the curriculum (ontology and objective (axiology. In the curriculum, the examined knowledge is religion and general knowledge. While the objective, Islamize knowledge and integrated Twin Towers aims to integrate religion and general knowledge, to dialogue, to communicate, and to synergy, so it can be a knowledge which is intact-integral-integrative.

  18. Seismic risk assessment of Trani's Cathedral bell tower in Apulia, Italy

    Science.gov (United States)

    Diaferio, Mariella; Foti, Dora

    2017-09-01

    The present paper deals with the evaluation of the seismic vulnerability of slender historical buildings; these structures, in fact, may manifest a high risk with respect to seismic actions as usually they have been designed to resist to gravitational loads only, and are characterized by a high flexibility. To evaluate this behavior, the bell tower of the Trani's Cathedral is investigated. The tower is 57 m tall and is characterized by an unusual building typology, i.e., the walls are composed of a concrete core coupled with external masonry stones. The dynamic parameters and the mechanical properties of the tower have been evaluated on the basis of an extensive experimental campaign that made use of ambient vibration tests and ground penetrating radar tests. Such data have been utilized to calibrate a numerical model of the examined tower. A linear static analysis, a dynamic analysis and a nonlinear static analysis have been carried out on such model to evaluate the displacement capacity of the tower and the seismic risk assessment in accordance with the Italian guidelines.

  19. Modification of the colony tower for the Rio Blanco detonation

    International Nuclear Information System (INIS)

    Blume, J.A.; Freeman, S.A.; Honda, K.K.; Lee, L.A.

    1975-01-01

    Supplemental structural bracing was designed and installed for the 180-ft-tall Colony Tower, an experimental oil shale processing retort structure, in anticipation of its lateral response to the Rio Blanco detonation. The tower is a steel structure with both horizontal and vertical diagonal bracing. Data obtained from the earlier Project Rulison detonation indicated that an evaluation study was necessary. Design criteria that would provide an adequate margin of safety were developed based on predicted Rio Blanco ground motion. The evaluation of the unmodified structure showed that several bracing members would be subjected to forces exceeding their yield strength, and some would reach a level at which failure could occur. Further analyses were made with assumed modified bracing members. A final scheme for modified vertical bracing was established and installed. After modification, the response of the tower during the Rio Blanco detonation was measured by instruments on the ground and at various locations on the tower, and no evidence of damage was discovered. The modification of the Colony Tower and the procedures used to determine these modifications show the usefulness of current ground motion and structural response prediction technology for forecasting dynamic behavior of important structures subjected to ground motion from underground nuclear explosions. (auth)

  20. Meteorological instrumentation for nuclear installations

    International Nuclear Information System (INIS)

    Costa, A.C.L. da.

    1983-01-01

    The main requirements of regulatory agencies, concerning the meteorological instrumentation needed for the licensing of nuclear facilities are discussed. A description is made of the operational principles of sensors for the various meteorological parameters and associated electronic systems. Finally, it is presented an analysis of the problems associated with grounding of a typical meteorological station. (Author) [pt

  1. De Reus van Schimmert : from a water tower to a green data center

    NARCIS (Netherlands)

    Tzanakakis, K.

    2017-01-01

    The water tower of Schimmert is an iconic tower that has served the local community for decades. In 2014 it was decommissioned and currently local companies and authorities are searching for a viable business model for this imposing tower. The present report examines the feasibility of transforming

  2. Tall Tower Wind Energy Monitoring and Numerical Model Validation in Northern Nevada

    Energy Technology Data Exchange (ETDEWEB)

    Koracin, D. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Kaplan, M. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Smith, C. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCurdy, G. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Wolf, A. [Desert Research Inst. (DRI), Las Vegas, NV (United States); McCord, T. [Desert Research Inst. (DRI), Las Vegas, NV (United States); King, K. [Desert Research Inst. (DRI), Las Vegas, NV (United States); Belu, R. [Drexel Univ., Philadelphia, PA (United States); Horvath, K. [Croatian Meteorological and Hydrological Service, Zagreb (Croatia)

    2015-10-01

    The main objectives of this project were to conduct a tall-tower and sodar field campaign in complex terrain, investigate wind properties relevant to wind energy assessment, and evaluate high-resolution models with fixed and adaptive grid structures. Two 60-m towers at Virginia Peak ridges near Washoe Valley, Nevada, were instrumented with cup and vane anemometers as well as sonic anemometers, and an acoustic sounder (hereafter sodar) was installed near one of the towers. The towers were located 2,700 m apart with a vertical distance of 140 m elevation between their bases. Each tower had a downhill exposure of rolling complex terrain, with the nearby valley floor 3,200 m to the west and 800 m below the summit. Cup anemometers were installed at both towers at 20, 40, and 60 m, wind vanes at 20 and 60 m, and sonic anemometers at 20 and 60 m. The sodar measurements were nominally provided every 10 m in vertical distance from 40 to 200 m with the quality of the data generally decreasing with height. Surface air temperature, atmospheric pressure, and radiation measurements were conducted at 1.5 m AGL at both of the towers. Although the plan was to conduct a 1-year period of data collection, we extended the period (October 5, 2012 through February 24, 2014) to cover for possible data loss from instrument or communication problems. We also present a preliminary analysis of the towers and sodar data, including a detailed inventory of available and missing data as well as outliers. The analysis additionally includes calculation of the Weibull parameters, turbulence intensity, and initial computation of wind power density at various heights.

  3. Experimental investigation of the performance characteristics of a counterflow wet cooling tower

    International Nuclear Information System (INIS)

    Lemouari, M.; Boumaza, M.

    2010-01-01

    An experimental investigation of the performance characteristics of a counter flow wet cooling tower represented by the heat rejected by the tower and its thermal effectiveness is presented in this paper. The tower is filled with a 'VGA.' (Vertical Grid Apparatus) type packing which is 0.42 m high and contains four (04) galvanized sheets having a zigzag form, between which are disposed three (03) metallic vertical grids in parallel with a cross-sectional test area of 0.15 m - 0.148 m. The investigation is concerned mainly on the effect of the air, water flow rates and the inlet water temperatures on the thermal effectiveness of the cooling tower as well as the heat rejected by this tower from water to be cooled to the air stream discharged into the atmosphere. The two operating regimes which were observed during the air/water contact inside the tower, a Pellicular Regime (PR) and a Bubble and Dispersion Regime (BDR) appear to be important, as The BDR regime enables to cool larger amount of water flow rates, while the Pellicular regime results with higher thermal effectiveness. (authors)

  4. Design change of tower cooling water system for proton accelerator research center

    International Nuclear Information System (INIS)

    Jeon, G. P.; Kim, J. Y.; Song, I. T.; Min, Y. S.; Mun, K. J.; Cho, J. S.; Nam, J. M.; Park, S. S.; Han, Y. G.

    2012-01-01

    The Tower Cooling Water System (TC) is designed to reject the heat load generated by operating the accelerators and the utility facilities through the component cooling water (CCW) heat exchangers. The circulating water discharged from the circulating water pumps passes through the CCW heat exchangers, the Chiller condenser and the air compressor, and the heated circulating water is return to the cooling tower for the heat removal. In this study, The design of Tower Cooling Water System is changed as follows : At First, The quantity of cells is changed into six in order to operate the cooling tower accurately correspond with condition of each equipment of head loads. The fans of cooling tower are controlled by the signal of TEW installed in the latter parts of it. The type of circulation water pump is modified to centrifugal pump and debris filter system is deleted

  5. Design change of tower cooling water system for proton accelerator research center

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, G. P.; Kim, J. Y.; Song, I. T.; Min, Y. S.; Mun, K. J.; Cho, J. S.; Nam, J. M.; Park, S. S.; Han, Y. G. [KAERI, Daejeon (Korea, Republic of)

    2012-10-15

    The Tower Cooling Water System (TC) is designed to reject the heat load generated by operating the accelerators and the utility facilities through the component cooling water (CCW) heat exchangers. The circulating water discharged from the circulating water pumps passes through the CCW heat exchangers, the Chiller condenser and the air compressor, and the heated circulating water is return to the cooling tower for the heat removal. In this study, The design of Tower Cooling Water System is changed as follows : At First, The quantity of cells is changed into six in order to operate the cooling tower accurately correspond with condition of each equipment of head loads. The fans of cooling tower are controlled by the signal of TEW installed in the latter parts of it. The type of circulation water pump is modified to centrifugal pump and debris filter system is deleted.

  6. Active tower damping and pitch balancing – design, simulation and field test

    International Nuclear Information System (INIS)

    Duckwitz, Daniel; Shan, Martin

    2014-01-01

    The tower is one of the major components in wind turbines with a contribution to the cost of energy of 8 to 12% [1]. In this overview the load situation of the tower will be described in terms of sources of loads, load components and fatigue contribution. Then two load reduction control schemes are described along with simulation and field test results. Pitch Balancing is described as a method to reduce aerodynamic asymmetry and the resulting fatigue loads. Active Tower Damping is reducing the tower oscillations by applying appropiate pitch angle changes. A field test was conducted on an Areva M5000 wind turbine

  7. Perhitungan Kebutuhan Cooling Tower Pada Rancang Bangun Untai Uji Sistem Kendali Reaktor Riset

    OpenAIRE

    Awwaluddin, Muhammad; Santosa, Puji; Suwardiyono, Suwardiyono

    2012-01-01

    CALCULATION OF THE NEED FOR COOLING TOWER ON DESIGN OF STRAND TEST RESEARCH REACTOR CONTROL SYSTEM. Cooling tower on the strand test engineering research reactor control system functioning as a heat transfer medium from the heat exchanger to air. To get the transfer of heat or cooling is maximal then the determination of cooling tower needs to be precise. Cooling tower is expected to accept and release heat at 1.191 kw from the heat exchanger. To support these needs will require the calculati...

  8. MODELLING AND ANALYSIS OF TOWER INTERVENTION EQUIPMENT OF OIL & GAS WELLS

    Directory of Open Access Journals (Sweden)

    César A. Chagoyén-Méndez

    2015-04-01

    Full Text Available In this paper, the modeling and analysis of one tower Workover Rig belonging to a maintenance facility for oil and gas wells is presented. When performing the maintenance of this tower, it is detected that one of the elements of the structure has some deformation. It was decided not to put it into operation and submit it to research. The modeling of invariants as well as ways of modeling soil structure interaction is discussed. It was necessary to determine the material properties with the performing of test of some samples taken on two components of the tower. The structural behavior of the tower to operating loads are then studied, proving that the effect of the deformed element in the structure is not significant for the stresses to which are subject.

  9. Pantex Plant meteorological monitoring program

    International Nuclear Information System (INIS)

    Snyder, S.F.

    1993-07-01

    The current meteorological monitoring program of the US Department of Energy's Pantex Plant, Amarillo, Texas, is described in detail. Instrumentation, meteorological data collection and management, and program management are reviewed. In addition, primary contacts are noted for instrumentation, calibration, data processing, and alternative databases. The quality assurance steps implemented during each portion of the meteorological monitoring program are also indicated

  10. Solar Power Tower Design Basis Document, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    ZAVOICO,ALEXIS B.

    2001-07-01

    This report contains the design basis for a generic molten-salt solar power tower. A solar power tower uses a field of tracking mirrors (heliostats) that redirect sunlight on to a centrally located receiver mounted on top a tower, which absorbs the concentrated sunlight. Molten nitrate salt, pumped from a tank at ground level, absorbs the sunlight, heating it up to 565 C. The heated salt flows back to ground level into another tank where it is stored, then pumped through a steam generator to produce steam and make electricity. This report establishes a set of criteria upon which the next generation of solar power towers will be designed. The report contains detailed criteria for each of the major systems: Collector System, Receiver System, Thermal Storage System, Steam Generator System, Master Control System, and Electric Heat Tracing System. The Electric Power Generation System and Balance of Plant discussions are limited to interface requirements. This design basis builds on the extensive experience gained from the Solar Two project and includes potential design innovations that will improve reliability and lower technical risk. This design basis document is a living document and contains several areas that require trade-studies and design analysis to fully complete the design basis. Project- and site-specific conditions and requirements will also resolve open To Be Determined issues.

  11. Improved reliability of wind turbine towers with active tuned mass dampers (ATMDs)

    Science.gov (United States)

    Fitzgerald, Breiffni; Sarkar, Saptarshi; Staino, Andrea

    2018-04-01

    Modern multi-megawatt wind turbines are composed of slender, flexible, and lightly damped blades and towers. These components exhibit high susceptibility to wind-induced vibrations. As the size, flexibility and cost of the towers have increased in recent years, the need to protect these structures against damage induced by turbulent aerodynamic loading has become apparent. This paper combines structural dynamic models and probabilistic assessment tools to demonstrate improvements in structural reliability when modern wind turbine towers are equipped with active tuned mass dampers (ATMDs). This study proposes a multi-modal wind turbine model for wind turbine control design and analysis. This study incorporates an ATMD into the tower of this model. The model is subjected to stochastically generated wind loads of varying speeds to develop wind-induced probabilistic demand models for towers of modern multi-megawatt wind turbines under structural uncertainty. Numerical simulations have been carried out to ascertain the effectiveness of the active control system to improve the structural performance of the wind turbine and its reliability. The study constructs fragility curves, which illustrate reductions in the vulnerability of towers to wind loading owing to the inclusion of the damper. Results show that the active controller is successful in increasing the reliability of the tower responses. According to the analysis carried out in this paper, a strong reduction of the probability of exceeding a given displacement at the rated wind speed has been observed.

  12. Going beyond the stationary flux towers to assess the interactions of land use and climate

    Science.gov (United States)

    Yakir, Dan; Rohatyn, shani; Ramati, Efrat; Tatrinov, Fedor; Rotenberg, Eyal

    2017-04-01

    Networks of permanent, stationary flux towers that allows continuous canopy-scale measurements over annual time-scales have revolutionized the study of the contemporary carbon cycle over the past two decades. However, this approach is limited in addressing questions related to dynamic changes in land use, vegetation types, disturbance, and their interactions with variations in environmental conditions. Using mobile laboratory for measuring CO2, water, energy, COS, and VOC fluxes, permitted us to extend our stationary flux tower measurements across many sites, but also limited measurements to short-time campaigns (days to weeks). To overcome this limitation, we adopted an empirical approach (often used in remote sensing) and used state of the art campaign-based ecosystem flux measurements to 'calibrate' local meteorological data available on continuous basis, to estimate annual-scale carbon, water, and energy budgets. Using this approach, we investigated the interactions of land use change (afforestation) and climate (humid Mediterranean to semi-arid, 730 to 300 mm in annual precipitation) on the ecosystem fluxes. The results showed that across this climatic range, afforestation increased ET markedly more in the wet (+200 mm yr-1 or 30% of P) than in the dry end (+58 mm yr-1 or 19% of P). Similarly, increase in carbon sequestration (NEE) associated with forestation was greater in the wet sites (+460 gC m-2 yr-1) than in the dry sites (+30 gC m-2 yr-1). In contrast, ecosystem net-radiation (Rn) and sensible heat flux (H) increased due to afforestation much more in the dry sites than in the wet sites ( 47 vs. 27 and 49 vs. 17 Wm-2, respectively). COS and VOC fluxes were also measured but reported separately. The results provided quantitative assessment of shifts in the tradeoffs associated with afforestation in this region, between the hydrological and energy-budget 'costs', vs. carbon sequestration and other ecosystem services, (e.g, surface cooling, erosion

  13. Database of meteorological and radiation measurements made in Belarus during the first three months following the Chernobyl accident

    International Nuclear Information System (INIS)

    Drozdovitch, Vladimir; Zhukova, Olga; Germenchuk, Maria; Khrutchinsky, Arkady; Kukhta, Tatiana; Luckyanov, Nickolas; Minenko, Victor; Podgaiskaya, Marina; Savkin, Mikhail; Vakulovsky, Sergey; Voillequé, Paul; Bouville, André

    2013-01-01

    Results of all available meteorological and radiation measurements that were performed in Belarus during the first three months after the Chernobyl accident were collected from various sources and incorporated into a single database. Meteorological information such as precipitation, wind speed and direction, and temperature in localities were obtained from meteorological station facilities. Radiation measurements include gamma-exposure rate in air, daily fallout, concentration of different radionuclides in soil, grass, cow's milk and water as well as total beta-activity in cow's milk. Considerable efforts were made to evaluate the reliability of the measurements that were collected. The electronic database can be searched according to type of measurement, date, and location. The main purpose of the database is to provide reliable data that can be used in the reconstruction of thyroid doses resulting from the Chernobyl accident. - Highlights: ► Meteorological and radiation measurements done after the Chernobyl accident in Belarus were collected. ► Data were verified and incorporated into a single database. ► Results of this study is being used to improve the thyroid dose estimates after the Chernobyl accident.

  14. Analysis of the evaporative towers cooling system of a coal-fired power plant

    Directory of Open Access Journals (Sweden)

    Laković Mirjana S.

    2012-01-01

    Full Text Available The paper presents a theoretical analysis of the cooling system of a 110 MW coal-fired power plant located in central Serbia, where eight evaporative towers cool down the plant. An updated research on the evaporative tower cooling system has been carried out to show the theoretical analysis of the tower heat and mass balance, taking into account the sensible and latent heat exchanged during the processes which occur inside these towers. Power plants which are using wet cooling towers for cooling condenser cooling water have higher design temperature of cooling water, thus the designed condensing pressure is higher compared to plants with a once-through cooling system. Daily and seasonal changes further deteriorate energy efficiency of these plants, so it can be concluded that these plants have up to 5% less efficiency compared to systems with once-through cooling. The whole analysis permitted to evaluate the optimal conditions, as far as the operation of the towers is concerned, and to suggest an improvement of the plant. Since plant energy efficiency improvement has become a quite common issue today, the evaluation of the cooling system operation was conducted under the hypothesis of an increase in the plant overall energy efficiency due to low cost improvement in cooling tower system.

  15. Theoretical and experimental study of a cross-flow induced-draft cooling tower

    Directory of Open Access Journals (Sweden)

    Abo Elazm Mahmoud Mohamed

    2009-01-01

    Full Text Available The main objective of this study is to find a proper solution for the cross-flow water cooling tower problem, also to find an empirical correlation's controlling heat and mass transfer coefficients as functions of inlet parameters to the tower. This is achieved by constructing an experimental rig and a computer program. The computer simulation solves the problem numerically. The apparatus used in this study comprises a cross-flow cooling tower. From the results obtained, the 'characteristic curve' of cross-flow cooling towers was constructed. This curve is very helpful for designers in order to find the actual value of the number of transfer units, if the values of inlet water temperature or inlet air wet bulb temperature are changed. Also an empirical correlation was conducted to obtain the required number of transfer units of the tower in hot water operation. Another correlation was found to obtain the effectiveness in the wet bulb operation.

  16. Climate and meteorology

    Energy Technology Data Exchange (ETDEWEB)

    Hoitink, D.J.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the significant activities conducted in 1994 to monitor the meteorology and climatology of the site. Meteorological measurements are taken to support Hanford Site emergency preparedness and response, Hanford Site operations, and atmospheric dispersion calculations. Climatological data are collected to help plan weather-dependent activities and are used as a resource to assess the environmental effects of Hanford Site operations.

  17. Climate and meteorology

    International Nuclear Information System (INIS)

    Hoitink, D.J.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the significant activities conducted in 1994 to monitor the meteorology and climatology of the site. Meteorological measurements are taken to support Hanford Site emergency preparedness and response, Hanford Site operations, and atmospheric dispersion calculations. Climatological data are collected to help plan weather-dependent activities and are used as a resource to assess the environmental effects of Hanford Site operations

  18. Productivity and CO2 exchange of Great Plains ecoregions. I. Shortgrass steppe: Flux tower estimates

    Science.gov (United States)

    Gilmanov, Tagir G.; Morgan, Jack A.; Hanan, Niall P.; Wylie, Bruce K.; Rajan, Nithya; Smith, David P.; Howard, Daniel M.

    2017-01-01

    The shortgrass steppe (SGS) occupies the southwestern part of the Great Plains. Half of the land is cultivated, but significant areas remain under natural vegetation. Despite previous studies of the SGS carbon cycle, not all aspects have been completely addressed, including gross productivity, ecosystem respiration, and ecophysiological parameters. Our analysis of 1998 − 2007 flux tower measurements at five Bowen ratio–energy balance (BREB) and three eddy covariance (EC) sites characterized seasonal and interannual variability of gross photosynthesis and ecosystem respiration. Identification of the nonrectangular hyperbolic equation for the diurnal CO2 exchange, with vapor pressure deficit (VPD) limitation and exponential temperature response, quantified quantum yield α, photosynthetic capacity Amax, and respiration rate rd with variation ranges (19 \\production from − 900 to + 700 g CO2 m− 2 yr− 1, indicating that SGS may switch from a sink to a source depending on weather. Comparison of the 2004 − 2006 measurements at two BREB and two parallel EC flux towers located at comparable SGS sites showed moderately higher photosynthesis, lower respiration, and higher net production at the BREB than EC sites. However, the difference was not related only to methodologies, as the normalized difference vegetation index at the BREB sites was higher than at the EC sites. Overall magnitudes and seasonal patterns at the BREB and the EC sites during the 3-yr period were similar, with trajectories within the ± 1.5 standard deviation around the mean of the four sites and mostly reflecting the effects of meteorology.

  19. The GEWEX LandFlux project: evaluation of model evaporation using tower-based and globally gridded forcing data

    Science.gov (United States)

    McCabe, M. F.; Ershadi, A.; Jimenez, C.; Miralles, D. G.; Michel, D.; Wood, E. F.

    2016-01-01

    ; 0.62), with values in parentheses representing the R2, RMSD and Nash-Sutcliffe efficiency (NSE), respectively. PM-Mu (0.51; 78 W m-2; 0.45) tended to underestimate fluxes, while SEBS (0.72; 101 W m-2; 0.24) overestimated values relative to observations. A focused analysis across specific biome types and climate zones showed considerable variability in the performance of all models, with no single model consistently able to outperform any other. Results also indicated that the global gridded data tended to reduce the performance for all of the studied models when compared to the tower data, likely a response to scale mismatch and issues related to forcing quality. Rather than relying on any single model simulation, the spatial and temporal variability at both the tower- and grid-scale highlighted the potential benefits of developing an ensemble or blended evaporation product for global-scale LandFlux applications. Challenges related to the robust assessment of the LandFlux product are also discussed.

  20. The GEWEX LandFlux project: evaluation of model evaporation using tower-based and globally-gridded forcing data

    Science.gov (United States)

    McCabe, M. F.; Ershadi, A.; Jimenez, C.; Miralles, D. G.; Michel, D.; Wood, E. F.

    2015-08-01

    parenthesis representing the R2, RMSD and Nash-Sutcliffe Efficiency (NSE) and respectively. PM-Mu (0.51; 78 W m-2; 0.45) tended to underestimate fluxes, while SEBS (0.72; 101 W m-2; 0.24) overestimated values relative to observations. A focused analysis across specific biome types and climate zones showed considerable variability in the performance of all models, with no single model consistently able to outperform any other. Results also indicated that the global gridded data tended to reduce the performance for all of the studied models when compared to the tower data, likely a response to scale mismatch and issues related to forcing quality. Rather than relying on any single model simulation, the spatial and temporal variability at both the tower- and grid-scale highlighted the potential benefits of developing an ensemble or blended evaporation product for global scale LandFlux applications. Challenges related to the robust assessment of the LandFlux product are also discussed.

  1. Development and testing of a system for meteorological and radiological data centralizing on Magurele zone

    International Nuclear Information System (INIS)

    Ciaus, M.; Niculescu, D.

    1997-01-01

    Within the framework of European collaboration co-ordinated by F.Z. Karlsruhe, the adapting, installing and developing of a decision support system for nuclear emergency management is now in progress in NIPNE. The decision support system RODOS will be available to the Romanian competent authorities - as well as to many western and eastern countries - in case of nuclear accidents. One main task in implementing the decision support system is to provide as input, among others, on-line real-time radiological and meteorological data, measured in national territory. For that purpose the regional and national measuring networks had to be connected to the central RODOS station in NIPNE. As the first step the sources of data existing on the Magurele zone were coupled to the RODOS system. The main sources of data are different meteorological sensors and flowmeters installed at three levels on the meteorological tower and a remote gamma-ray area monitor with several measuring locations in Magurele zone, connected by radio links to the central unit in Nuclear Instruments and Methods Department. For transmission of collected data to the central RODOS station, a local area network was implemented to connect all the computers. The Ethernet - based network uses optical fiber between buildings, coaxial and twisted cable inside buildings and suitable Hewlett-Packard hubs and transceivers. Several communication software packages based on TCP/IP protocols were installed on the computers and tested. The real-time data transfer between collecting computers and the central station will be carried out by automatic triggering of FTP programs at regular time intervals. The local network provides also a link to Internet, so that the indispensable exchange of data with similar RODOS centers in other countries, especially with the coordinating institute in Karlsruhe, as well as with other organizations is ensured. (authors)

  2. Membrane distillation of industrial cooling tower blowdown water

    Directory of Open Access Journals (Sweden)

    N.E. Koeman-Stein

    2016-06-01

    Full Text Available The potential of membrane distillation for desalination of cooling tower blowdown water (CTBD is investigated. Technical feasibility is tested on laboratory and pilot scale using real cooling tower blowdown water from Dow Benelux in Terneuzen (Netherlands. Two types of membranes, polytetrafluorethylene and polyethylene showed good performance regarding distillate quality and fouling behavior. Concentrating CTBD by a factor 4.5 while maintaining a flux of around 2 l/m2*h was possible with a water recovery of 78% available for reuse. Higher concentration factors lead to severe decrease in flux which was caused by scaling. Membrane distillation could use the thermal energy that would otherwise be discharged of in a cooling tower and function as a heat exchanger. This reduces the need for cooling capacity and could lead to a total reduction of 37% water intake for make-up water, as well as reduced energy and chemicals demands and greenhouse gas emissions.

  3. Fatigue Reliability Analysis of a Mono-Tower Platform

    DEFF Research Database (Denmark)

    Kirkegaard, Poul Henning; Sørensen, John Dalsgaard; Brincker, Rune

    1991-01-01

    In this paper, a fatigue reliability analysis of a Mono-tower platform is presented. The failure mode, fatigue failure in the butt welds, is investigated with two different models. The one with the fatigue strength expressed through SN relations, the other with the fatigue strength expressed thro...... of the natural period, damping ratio, current, stress spectrum and parameters describing the fatigue strength. Further, soil damping is shown to be significant for the Mono-tower.......In this paper, a fatigue reliability analysis of a Mono-tower platform is presented. The failure mode, fatigue failure in the butt welds, is investigated with two different models. The one with the fatigue strength expressed through SN relations, the other with the fatigue strength expressed...... through linear-elastic fracture mechanics (LEFM). In determining the cumulative fatigue damage, Palmgren-Miner's rule is applied. Element reliability, as well as systems reliability, is estimated using first-order reliability methods (FORM). The sensitivity of the systems reliability to various parameters...

  4. Optimum Tower Crane Selection and Supporting Design Management

    Directory of Open Access Journals (Sweden)

    Hyo Won Sohn

    2014-08-01

    Full Text Available To optimize tower crane selection and supporting design, lifting requirements (as well as stability should be examined, followed by a review of economic feasibility. However, construction engineers establish plans based on data provided by equipment suppliers since there are no tools with which to thoroughly examine a support design's suitability for various crane types, and such plans lack the necessary supporting data. In such cases it is impossible to optimize a tower crane selection to satisfy lifting requirements in terms of cost, and to perform lateral support and foundation design. Thus, this study is intended to develop an optimum tower crane selection and supporting design management method based on stability. All cases that are capable of generating an optimization of approximately 3,000 ˜ 15,000 times are calculated to identify the candidate cranes with minimized cost, which are examined. The optimization method developed in the study is expected to support engineers in determining the optimum lifting equipment management.

  5. Talking Towers, Making Withs.

    Science.gov (United States)

    Lemke, J. L.

    The notion of a linguistic "register" is useful in posing questions about how the ways language is used differ from one kind of human activity to another. This paper analyzes a videotaped segment of male grade 4/5 students (n=3) who are talking as they work to build a tower from plastic drinking straws and pins. Discussion of the…

  6. How tall can gelatin towers be? An introduction to elasticity and buckling

    Science.gov (United States)

    Taberlet, Nicolas; Ferrand, Jérémy; Camus, Élise; Lachaud, Léa; Plihon, Nicolas

    2017-12-01

    The stability of elastic towers is studied through simple hands-on experiments. Using gelatin-based stackable bricks, one can investigate the maximum height a simple structure can reach before collapsing. We show through experiments and by using the classical linear elastic theory that the main limitation to the height of such towers is the buckling of the elastic structures under their own weight. Moreover, the design and architecture of the towers can be optimized to greatly improve their resistance to self-buckling. To this aim, the maximum height of hollow and tapered towers is investigated. The experimental and theoretical developments presented in this paper can help students grasp the fundamental concepts in elasticity and mechanical stability.

  7. Induced flocculation of Pachysolen tannophilus using the tower fermentor

    Energy Technology Data Exchange (ETDEWEB)

    Deverell, K.F.; Clark, T.A.

    1985-12-01

    This article reports the induction of flocculation with Pachysolen tannophilus by the use of controlled aeration in a tower fermentor. The observed environmental and physiological conditions for flocculent growth are described. Although most studies with P. tannophilus have used oxylose as substrate, a synthetic glucose medium was chosen for this study as the faster growth rate of the organism on glucose was considered to favor more rapid selection of a flocculent strain. Due to flocculation, the concentration of yeast cells retained in the tower was up to 16 times greater than in the overflow. Ethanol yields approaching theoretical were achieved at low specific oxygen uptake rates, conditions which also favored maximum flocculation. Future work will involve continuous tower fermentation of sugar mixtures representative of the composition of wood hydrolysates.

  8. Cooling Tower Overhaul of Secondary Cooling System in HANARO

    Energy Technology Data Exchange (ETDEWEB)

    Park, Young Chul; Lee, Young Sub; Jung, Hoan Sung; Lim, In Chul [KAERI, Daejeon (Korea, Republic of)

    2007-07-01

    HANARO, an open-tank-in-pool type research reactor of 30 MWth power in Korea, has been operating normally since its initial criticality in February, 1995. For the last about ten years, A cooling tower of a secondary cooling system has been operated normally in HANARO. Last year, the cooling tower has been overhauled for preservative maintenance including fills, eliminators, wood support, water distribution system, motors, driving shafts, gear reducers, basements, blades and etc. This paper describes the results of the overhaul. As results, it is confirmed that the cooling tower maintains a good operability through a filed test. And a cooling capability will be tested when a wet bulb temperature is maintained about 28 .deg. C in summer and the reactor is operated with the full power.

  9. Alkaline approach to treating cooling towers for control of Legionella pneumophila

    Energy Technology Data Exchange (ETDEWEB)

    States, S.J.; Conley, L.F.; Towner, S.G.; Wolford, R.S.; Stephenson, T.E.; McNamara, M.; Wadowsky, R.M.; Yee, R.B.

    1987-08-01

    Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggest that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospital cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.

  10. Exploring the link between meteorological drought and streamflow to inform water resource management

    Science.gov (United States)

    Lennard, Amy; Macdonald, Neil; Hooke, Janet

    2015-04-01

    Drought indicators are an under-used metric in UK drought management. Standardised drought indicators offer a potential monitoring and management tool for operational water resource management. However, the use of these metrics needs further investigation. This work uses statistical analysis of the climatological drought signal based on meteorological drought indicators and observed streamflow data to explore the link between meteorological drought and hydrological drought to inform water resource management for a single water resource region. The region, covering 21,000 km2 of the English Midlands and central Wales, includes a variety of landscapes and climatological conditions. Analysis of the links between meteorological drought and hydrological drought performed using streamflow data from 'natural' catchments indicates a close positive relationship between meteorological drought indicators and streamflow, enhancing confidence in the application of drought indicators for monitoring and management. However, many of the catchments in the region are subject to modification through impoundments, abstractions and discharge. Therefore, it is beneficial to explore how climatological drought signal propagates into managed hydrological systems. Using a longitudinal study of catchments and sub-catchments that include natural and modified river reaches the relationship between meteorological and hydrological drought is explored. Initial statistical analysis of meteorological drought indicators and streamflow data from modified catchments shows a significantly weakened statistical relationship and reveals how anthropogenic activities may alter hydrological drought characteristics in modified catchments. Exploring how meteorological drought indicators link to streamflow across the water supply region helps build an understanding of their utility for operational water resource management.

  11. Design and Manufacturing of Composite Tower Structure for Wind Turbine Equipment

    Science.gov (United States)

    Park, Hyunbum

    2018-02-01

    This study proposes the composite tower design process for large wind turbine equipment. In this work, structural design of tower and analysis using finite element method was performed. After structural design, prototype blade manufacturing and test was performed. The used material is a glass fiber and epoxy resin composite. And also, sand was used in the middle part. The optimized structural design and analysis was performed. The parameter for optimized structural design is weight reduction and safety of structure. Finally, structure of tower will be confirmed by structural test.

  12. Wind towers architecture, climate and sustainability

    CERN Document Server

    Bahadori, Mehdi N; Sayigh, Ali

    2014-01-01

    This book offers a holistic treatment of wind towers, from their underlying scientific principles to design and operation. Includes suggestions for optimization based on the authors' own research findings from recent analytical studies.

  13. Two upward lightning at the Eagle Nest tower

    OpenAIRE

    Montañá Puig, Juan; Van der Velde, Oscar Arnoud; Romero Durán, David; March Nomen, Víctor; Solà de Las Fuentes, Gloria; Pineda Ruegg, Nicolau; Soula, Serge; Hermoso Alameda, Blas

    2012-01-01

    A new instrument composed by a high speed camera, two high energy detectors, a E-field antenna and a VHF antenna were installed at the Eagle Nest tower (northeast of Spain) during summer 2011. With this equipment several lightning flashes to the tower and its vicinity have been observed. This paper presents two examples: the first was an upward negative leader triggered by a close c1oud-to-ground flash and the second was an upward negative flash not associated with previous lightning activity...

  14. Journal of Meteorology and Climate Science

    African Journals Online (AJOL)

    The Journal of Meteorology and Climate Science publishes rigorous theoretical reasoning and advanced empirical research in all areas of Meteorology and Climate Sciences. We welcome articles or proposals from all perspectives and on all subjects pertaining to Meteorology, Agriculture, Humanity, Physics, Geography, ...

  15. Emission of asbestos fibres from natural-draught cooling towers. Pt. 1 and 2

    International Nuclear Information System (INIS)

    Ernst, G.; Althaus, E.; Karotke, E.; Grimm, K.; Heumann, H.G.; Rueckert, G.

    1985-01-01

    Sampling for the studies reported has been done in a relatively new nuclear power plant with natural-draught, wet cooling tower, and in an older, brown-coal fired power plant with the same type of cooling towers, both towers equipped with internal structures made of asbestos cement. Samples have been taken from the plumes, air in the environment, cooling water receiving tank, make-up water. The samples have been primarily examined for their content of asbestos fibres. The results show that relatively few asbestos is found in the environmental air and in the cooling water receiving tank. Putting it continuously, it can be said that the cooling water entrains only little amounts of the asbestos of the internal structures. The plume samples indicate emission of some thousand asbestos fibres per m 3 , or less than 1 ng. Taking into account one sample exhibiting an extremely high amount of asbestos, the average emission of asbestos fibres with the plumes is 10 6 fibres per m 3 , or 100 ng/m 3 of plume. The maximum air pollution thus calculated in accordance with TA Luft (Clean Air Technical Directive), for the less favourable weather conditions at a hight of 2 m above ground, is 10 fibres per one m 3 of air; including the extreme data of the single sample mentioned above, the result is some thousand fibres per m 3 . The data are far below the TRK data (Technical guiding data for maximum concentration at the place of work), which state a maximum of 10 6 fibres per m 3 . (orig.) [de

  16. Visibility analysis of fire lookout towers in the Boyabat State Forest Enterprise in Turkey.

    Science.gov (United States)

    Kucuk, Omer; Topaloglu, Ozer; Altunel, Arif Oguz; Cetin, Mehmet

    2017-07-01

    For a successful fire suppression, it is essential to detect and intervene forest fires as early as possible. Fire lookout towers are crucial assets in detecting forest fires, in addition to other technological advancements. In this study, we performed a visibility analysis on a network of fire lookout towers currently operating in a relatively fire-prone region in Turkey's Western Black Sea region. Some of these towers had not been functioning properly; it was proposed that these be taken out of the grid and replaced with new ones. The percentage of visible areas under the current network of fire lookout towers was 73%; it could rise to 81% with the addition of newly proposed towers. This study was the first research to conduct a visibility analysis of current and newly proposed fire lookout towers in the Western Black Sea region and focus on its forest fire problem.

  17. The influence of liquid-gas velocity ratio on the noise of the cooling tower

    Science.gov (United States)

    Yang, Bin; Liu, Xuanzuo; Chen, Chi; Zhao, Zhouli; Song, Jinchun

    2018-05-01

    The noise from the cooling tower has a great influence on psychological performance of human beings. The cooling tower noise mainly consists of fan noise, falling water noise and mechanical noise. This thesis used DES turbulence model with FH-W model to simulate the flow and sound pressure field in cooling tower based on CFD software FLUENT and analyzed the influence of different kinds noise, which affected by diverse factors, on the cooling tower noise. It can be concluded that the addition of cooling water can reduce the turbulence and vortex noise of the rotor fluid field in the cooling tower at some extent, but increase the impact noise of the liquid-gas two phase. In general, the cooling tower noise decreases with the velocity ratio of liquid to gas increasing, and reaches the lowest when the velocity ratio of liquid to gas is close to l.

  18. Quantifying the local influence at a tall tower site in nocturnal conditions

    Energy Technology Data Exchange (ETDEWEB)

    Werth, David; Buckley, Robert; Zhang, Gengsheng; Kurzeja, Robert; Leclerc, Monique; Duarte, Henrique; Parker, Matthew; Watson, Thomas

    2015-10-17

    The influence of the local terrestrial environment on nocturnal atmospheric CO2 measurements at a 329-m television transmitter tower (and a component of a CO2 monitoring network) was estimated with a tracer release experiment and a subsequent simulation of the releases. This was done to characterize the vertical transport of emissions from the surface to the uppermost tower level and how it is affected by atmospheric stability. The tracer release experiment was conducted over two nights in May of 2009 near the Department of Energy’s Savannah River Site (SRS) in South Carolina. Tracer was released on two contrasting nights—slightly stable and moderately stable—from several upwind surface locations. Measurements at the 329-m level on both nights indicate that tracer was able to mix vertically within a relatively short (~24 km) distance, implying that nocturnal stable conditions do not necessarily prevent vertical dispersion in the boundary layer and that CO2 measurements at the tower are at least partly influenced by nearby emissions. A simulation of the tracer release is used to calculate the tower footprint on the two nights to estimate the degree to which the local domain affects the tower readings. The effect of the nocturnal boundary layer on the area sampled by the tower can be seen clearly, as the footprints were affected by changes in stability. The contribution of local sources to the measurements at the tower was minimal, however, suggesting that nocturnal concentrations at upper levels are contributed mostly by regional sources.

  19. Comparative study on thermal performance of natural draft cooling towers with finned shells

    International Nuclear Information System (INIS)

    Goodarzi, Mohsen

    2016-01-01

    The cooling efficiency of natural draft cooling towers under crosswind condition should be improved. In the present research work three different externally finned shells were considered for a typical natural draft cooling tower to investigate the cooling improvement. They were numerically simulated under normal and crosswind conditions. Numerical results show that twisting four fin plates over the tower shell along the 45 peripheral angle, could improve the cooling efficiency up to 6.5 %. Because of the periodic shape of the fin plates, the cooling efficiency of the cooling tower with finned shell is less sensitive to the change of wind.

  20. Comparative study on thermal performance of natural draft cooling towers with finned shells

    Energy Technology Data Exchange (ETDEWEB)

    Goodarzi, Mohsen [Bu-Ali Sina Univ., Hamedan (Iran, Islamic Republic of). Dept. of Mechanical Engineering

    2016-10-15

    The cooling efficiency of natural draft cooling towers under crosswind condition should be improved. In the present research work three different externally finned shells were considered for a typical natural draft cooling tower to investigate the cooling improvement. They were numerically simulated under normal and crosswind conditions. Numerical results show that twisting four fin plates over the tower shell along the 45 peripheral angle, could improve the cooling efficiency up to 6.5 %. Because of the periodic shape of the fin plates, the cooling efficiency of the cooling tower with finned shell is less sensitive to the change of wind.

  1. A Model for Interpreting High-Tower CO2 Concentration Records for the Surface Carbon Balance Information

    Science.gov (United States)

    Chen, B.; Chen, J. M.; Higuchi, K.; Chan, D.; Shashkov, A.

    2002-05-01

    Atmospheric CO2 concentration measurements have been made by scientists of Meteorological Service of Canada on a 40 m tower for the last 10 years at 15 minute intervals over a mostly intact boreal forest near Fraserdale (50N, 81W), Ontario, Canada. The long time records of CO2 as well as basic meteorological variables provide a unique opportunity to investigate any potential changes in the ecosystem in terms of carbon balance. A model is needed to decipher the carbon cycle signals from the diurnal and seasonal variation patterns in the CO2 record. For this purpose, the Boreal Ecosystem Productivity Simulator (BEPS) is expanded to include a one-dimensional CO2 vertical transfer model involving the interaction between plant canopies and the atmosphere in the surface layer and the diurnal dynamics of the mixed layer. An analytical solution of the scalar transfer equation within the surface layer is found using an assumption that the diurnal oscillation of CO2 concentration at a given height is sinusoidal, which is suitable for the investigation of the changes in diurnal variation pattern over the 10 year period. The complex interactions between the daily cycle of the atmosphere and vegetation CO2 exchange and the daily evolution of mixed layer entrainment of CO2 determines the CO2 variation pattern at a given height. The expanded BEPS can simulate within ñ2 ppm the hourly CO2 records at the 40 m measurement height. The annual totals of gross primary productivity (GPP), net primary productivity (NPP) and net ecosystem productivity (NEP), summed up from the hourly results, agree within 5% of previous estimates of BEPS at daily steps, indicating the internal consistency of the hourly model. The model is therefore ready for exploring changes in the CO2 record as affected by changes in the forest ecosystems upwind of the tower. Preliminary results indicate that the diurnal variation amplitude of CO2 has increased by 10-20% over the 10 years period, and this change can

  2. Further investigation on the performance of a shower cooling tower

    International Nuclear Information System (INIS)

    Qi Xiaoni; Liu Zhenyan

    2008-01-01

    This study was prompted by the need to design towers for applications in which, due to salt deposition on the packing and subsequent blockage, the use of tower packing is not practical. In the previous model we presented [Qi Xiaoni, Liu Zhenyan, Li Dandan. Performance characteristics of a shower cooling tower. Energy Convers Manage 2007;48(1):193-203.], three critical assumptions were made to reduce the complexity and computational time, which can also reduce the models' accuracy. Accurate modelling of the operating process is a determining factor both for designing the shower cooling tower (SCT) and for optimising its operation. In this paper, we derive a new model without applying the three assumptions. According to the condition of the outlet air, the governing equations consider two cases, including the supersaturated and unsaturated states. This model is used to predict the performance of a full scale SCT located in China with different conditions for validation. The differences in the heat and mass transfer analyses of the two models are described at different atmospheric conditions

  3. 40 CFR 61.134 - Standard: Naphthalene processing, final coolers, and final-cooler cooling towers.

    Science.gov (United States)

    2010-07-01

    ... coolers, and final-cooler cooling towers. 61.134 Section 61.134 Protection of Environment ENVIRONMENTAL... Standard: Naphthalene processing, final coolers, and final-cooler cooling towers. (a) No (“zero”) emissions are allowed from naphthalene processing, final coolers and final-cooler cooling towers at coke by...

  4. Hexcrete Tower for Harvesting Wind Energy at Taller Hub Heights - Budget Period 2

    Energy Technology Data Exchange (ETDEWEB)

    Sritharan, Sri [Iowa State Univ., Ames, IA (United States)

    2017-05-01

    Interest in designing taller towers for wind energy production in the United States (U.S.) has been steadily growing. In May 2015, it was revealed that taller towers will make wind energy production a reality in all 50 states, including some states that have nearly zero renewables in their energy portfolio. Facilitating wind energy production feasibility in all 50 states will no doubt contribute to increasing the electricity produced by wind from 4.5% in 2013 to a targeted scenario of 35% by 2050 in the Wind Vision report. This project focuses on the Hexcrete tower concept developed for tall towers using High Strength Concrete (HSC) and/or Ultra-High Performance Concrete (UHPC). Among other benefits, the Hexcrete concept overcomes transportation and logistical challenges, thus facilitating construction of towers with hub heights of 100-m (328-ft) and higher. The goal of this project is to facilitate widespread deployment of Hexcrete towers for harvesting wind energy at 120 to 140-m (394 to 459-ft) hub heights and reduce the Levelized Cost of Energy (LCOE) of wind energy production in the U.S. The technical scope of the project includes detailed design and optimization of at least three wind turbine towers using the Hexcrete concept together with experimental validation and LCOE analyses and development of a commercialization plan.

  5. Building 'Tower' on the Partizans square in Užice (1961

    Directory of Open Access Journals (Sweden)

    Kuzović Duško

    2016-01-01

    Full Text Available The building 'Tower' at the Partisans Square in Užice was built from 1958 to 1961 designed by architect Milorad Pantović. It is located in the north zone on the street of Kralja Petra, in a continuous series of buildings that form the eastern side of the square room. Thanks to the topography of the terrain and the amount of public space, the tower dominates the square. Floors: Basement 1 + 2 basement + ground + mezzanine + 11 floors + attic. Tower at the Partisans Square represents the first multi-storey building which was built in Užice. The architectural value of the building represents a significant segment of the architectural heritage in Serbia and Yugoslavia.

  6. Heat Transfer Enhancement of the Air-Cooling Tower with Rotating Wind Deflectors under Crosswind Conditions

    Directory of Open Access Journals (Sweden)

    Xueping Du

    2018-04-01

    Full Text Available To investigate the effect of wind deflectors on air flow and heat transfer performance of an air-cooling tower under crosswind conditions, an experimental system based on a surface condenser aluminum exchanger-type indirect air-cooling tower is established at a 1:100 proportional reduction. A 3-D computational fluid dynamics simulation model is built to study the air flow and temperature fields. The air flow rate into the cooling tower and the heat transfer rate of the radiators are used to evaluate cooling performance. Rotating wind deflectors are adopted to reduce the influence of crosswind on the cooling tower performance. The effects of the rotating wind deflectors on the thermal-hydraulic characteristics of the air-cooling tower under different environmental crosswind speeds are studied. Results indicate that the wind direction in the tower reverses as the rotating speed of the wind deflectors increases. The thermal performance of an air-cooling tower under crosswind conditions can be improved by using rotating wind deflectors. The heat transfer rate of a cooling tower with eight wind deflectors begins to increase when the rotating speed exceeds 2 r/min.

  7. Deuterium- and 18O-content in the cooling water of power station cooling towers

    International Nuclear Information System (INIS)

    Heimbach, H.; Dongmann, G.

    1976-09-01

    The 0-18/0-16 and D/H isotope ratios of water from two different cooling towers were determined by mass spectrometry. The observed isotope fractionation corresponds to that known from natural evaporation or transpiration processes: cooling tower I: delta(D) = 46.8 per thousand, delta( 18 O) = 7.6 per thousand cooling tower II: delta(D) = 33.9 per thousand delta( 18 O) = 5.7 per thousand Evaluation of simple compartment models of a cooling tower and a distillation device suggests that there exists some isotope discrimination within the open trickling unit of a cooling tower analogous to that in a rectification column. In a real cooling tower, however, this effect is compensated largely by the recycling of the cooling water, resulting only in a small enrichment of the heavy isotopes. This can be understood as the result of three partial effects: 1) a fractionation in the vapor pressure equilibrium, 2) a kinetic effect due to diffusion of the water vapor into a turbulent atmosphere, and 3) an exchange effect which is proportional to relative humidity. This low enrichment of the heavy isotope excludes the technical use of cooling towers as isotope separation devices. (orig.) [de

  8. Experimental investigation of the hydraulic characteristics of a counter flow wet cooling tower

    International Nuclear Information System (INIS)

    Lemouari, M.; Boumaza, M.; Kaabi, A.

    2011-01-01

    Thermal and nuclear electric power plants as well as several industrial processes invariably discharge considerable energy to their surrounding by heat transfer. Although water drawn from a nearby river or lake can be employed to carry away this energy, cooling towers offer an excellent alternative particularly in locations where sufficient cooling water cannot be easily obtained from natural sources or where concern for the environment imposes some limits on the temperature at which cooling water can be returned to the surrounding. This paper concerns an experimental investigation of the hydraulic characteristics of a counter flow wet cooling tower. The tower contains a 'VGA.' (Vertical Grid Apparatus) type packing which is 0.42 m high and consists of four (04) galvanised sheets having a zigzag form, between which are disposed three (03) metallic vertical grids in parallel with a cross sectional test area of 0.15 m x 0.148 m. The present investigation is focused mainly on the effect of the air and water flow rates on the hydraulic characteristics of the cooling tower, for different inlet water temperatures. The two hydrodynamic operating regimes which were observed during the air/water contact operation within the tower, namely the Pellicular Regime (PR) and the Bubble and Dispersion Regime (BDR) have enabled to distinguish two different states of pressure drop characteristics. The first regime is characterized by low pressure drop values, while in the second regime, the pressure drop values are relatively much higher than those observed in the first one. The dependence between the pressure drop characteristics and the combined heat and mass transport (air-water) through the packing inside the cooling tower is also highlighted. The obtained results indicate that this type of tower possesses relatively good hydraulic characteristics. This leads to the saving of energy. -- Highlights: → Cooling towers are widely used to reject waste heat from thermal and nuclear

  9. Design of cooling towers by the effectiveness-NTU method

    International Nuclear Information System (INIS)

    Jaber, H.; Webb, R.L.

    1989-01-01

    This paper develops the effectiveness-NTU, number of transfer units, design method for cooling towers. The definitions for effectiveness and NTU are totally consistent with the fundamental definitions used in heat exchanger design. Sample calculations are presented for counter and crossflow cooling towers. Using the proper definitions, a person competent in heat transfer design can easily use the same basic method to design a cooling tower of counter, cross, or parallel flow configuration. The problems associated with the curvature of the saturated air enthalpy line are also treated. A one-increment design ignores the effect of this curvature. Increased precision can be obtained by dividing the cooling range into two or more increments. The standard effectiveness-NYU method is then used for each of the increments. Calculations are presented to define the error associated with different numbers of increments. This defines the number of increments required to attain a desired degree of precision. The authors also summarize the LMED method introduced by Berman, and show that this is totally consistent with the effectiveness-NTU method. Hence, using proper and consistent terms, heat exchanger designers are shown how to use either the standard Log-Mean Enthalpy Method (LMED) or effectiveness-NTU design methods to design cooling towers

  10. Tokyo Tower and Tokyo Skytree: History and Symbolism in Contemporary Japan

    Directory of Open Access Journals (Sweden)

    Yunuen Ysela Mandujano-Salazar

    2016-12-01

    Full Text Available The Tokyo Tower and the Tokyo Skytree are the two most recognizable landmarks on the skyline of Japan’s capital. By means of a documental revision, a textual interpretative analysis of media contents, participant observation and unstructured interviews, the objective of this article is to identify the development of these towers as symbols of Tokyo and Japan. It is found that, with more than half a century of existence, the Tokyo Tower represents the successful post-war Japanese society, while in just five years the Tokyo Skytree has become a symbol of Japanese national spirit and resilience in an era of multiple crises. Both broadcasting towers are regularly portrayed in Japanese media linked to narratives of romance, dreams, family and community. Also, enhanced by their special lightening at night, they stand as attractive backgrounds for locals and visitors in relevant events in their lives.

  11. Syllabi for Instruction in Agricultural Meteorology.

    Science.gov (United States)

    De Villiers, G. D. B.; And Others

    A working group of the Commission for Agricultural Meteorology has prepared this report to fill a need for detailed syllabi for instruction in agricultural meteorology required by different levels of personnel. Agrometeorological personnel are classified in three categories: (1) professional meteorological personnel (graduates with basic training…

  12. Towards Cooling Tower Efficiency-An Energy Audit Approach

    Directory of Open Access Journals (Sweden)

    Long Su Weng Alwin

    2017-01-01

    Full Text Available This research studied the power generation trends from national grid and gas for a period of 4 years. Energy audit of critical systems like this is needful for optimal energy utilization. An energy audit was carried outon 6 industrial cooloing towers and their annual operating cost calculated. Variable speed drive suggested was installed and corresponding annual energy savings of 114,900 kWh/year cost saving of RM30,000 was achieved at a case study plant located in Malaysia. Cooling towers with smart systems was recommended for higher energy savings.

  13. Meteorological controls on the diurnal variability of carbon monoxide mixing ratio at a mountaintop monitoring site in the Appalachian Mountains

    Directory of Open Access Journals (Sweden)

    Temple R. Lee

    2015-05-01

    Full Text Available The variability of trace gases such as carbon monoxide (CO at surface monitoring stations is affected by meteorological forcings that are particularly complicated over mountainous terrain. A detailed understanding of the impact of meteorological forcings on trace gas variability is challenging, but is vital to distinguish trace gas measurements affected by local pollutant sources from measurements representative of background mixing ratios. In the present study, we investigate the meteorological and CO characteristics at Pinnacles (38.61 N, 78.35 W, 1017 m above mean sea level, a mountaintop monitoring site in northwestern Virginia, USA, in the Appalachian Mountains, from 2009 to 2012, and focus on understanding the dominant meteorological forcings affecting the CO variability on diurnal timescales. The annual mean diurnal CO cycle shows a minimum in the morning between 0700 and 0900 LST and a maximum in the late afternoon between 1600 and 2000 LST, with a mean (median daily CO amplitude of 39.2±23.7 ppb (33.2 ppb. CO amplitudes show large day-to-day variability. The largest CO amplitudes, in which CO mixing ratios can change >100 ppb in <3 h, occur in the presence of synoptic disturbances. Under fair weather conditions, local- to regional-scale transport processes are found to be more important drivers of the diurnal CO variability. On fair weather days with northwesterly winds, boundary layer dilution causes a daytime CO decrease, resembling the variability observed atop tall towers in flat terrain. Fair weather days with a wind shift from the northwest to the south are characterised by an afternoon CO increase and resemble the variability observed at mountaintops influenced by the vertical transport of polluted air from adjacent valleys.

  14. Surface Meteorology and Solar Energy

    Data.gov (United States)

    National Aeronautics and Space Administration — Surface Meteorology and Solar Energy data - over 200 satellite-derived meteorology and solar energy parameters, monthly averaged from 22 years of data, global solar...

  15. Measurement of NOx and CO Fluxes from a Tall Tower in Beijing.

    Science.gov (United States)

    Squires, F. A.; Drysdale, W. S.; Hamilton, J.; Lee, J. D.; Vaughan, A. R.; Wild, O.; Mullinger, N.; Nemitz, E.; Metzger, S.; Zhang, Q.

    2017-12-01

    China's air quality problems are well publicised; in 2010, 1.2 million premature deaths were attributed to outdoor air pollution in China. One of the major air quality issues is high concentrations of nitrogen oxides (NOx). China is the largest NOx emitter, contributing an estimated 18 % to global NOx emissions. Beijing itself is reported to have NO2 concentrations 42 % higher than the annual national standard. Given the high levels of pollution, increased focus has been placed on improving emissions estimates which are typically developed using a `bottom-up' approach where emissions are predicted from their sources. Emission inventories in China have large uncertainties and are rapidly changing with time in response to economic development, environmental regulation and new technologies. In fact, China is the largest contributor to the uncertainty in the source and the magnitude of air pollutants in air quality models. Recent studies have shown a discrepancy between NOx inventories and measured NOx emissions for UK cities, highlighting the limitations of bottom-up emissions inventories and the importance of accurate measurement data to improve the estimates. 5 Hz measurements of NOx and CO concentration were made as part of the Air Pollutants in Beijing (AIRPOLL-Beijing) project during two field campaigns in Nov-Dec 2016 and May-June 2017. Sampling took place from an inlet co-located with a sonic anemometer at 102 m on a meteorological tower in central Beijing. Analysis of the covariance between vertical wind speed and concentration enabled the calculation of emission flux, with an estimated footprint of between 2 - 5 km from the tower (which typically included some major ring roads and expressways). Fluxes were quantified using the continuous wavelet transformation (CWT) method, which enabled one minute resolved fluxes to be calculated. These data were compared to existing emissions estimates from the Multi-resolution Emission Inventory for China (MEIC). It is

  16. Isolation of Legionella pneumophila from hospital cooling towers in Johor, Malaysia.

    Science.gov (United States)

    Abdul Samad, B H; Suhaili, M R; Baba, N; Rajasekaran, G

    2004-08-01

    Water-based cooling towers and their water supply at two hospitals in Johor were surveyed for the presence Legionella pneumophila. L. pneumophila were grown from 19 (76%) out of 25 collected water samples. One hospital cooling tower was contaminated with L. pneumophila serogroup 1.

  17. Laboratory Experiment and Numerical Analysis of a New Type of Solar Tower Efficiently Generating a Thermal Updraft

    Directory of Open Access Journals (Sweden)

    Yuji Ohya

    2016-12-01

    Full Text Available A new type of solar tower was developed through laboratory experiments and numerical analyses. The solar tower mainly consists of three components. The transparent collector area is an aboveground glass roof, with increasing height toward the center. Attached to the center of the inside of the collector is a vertical tower within which a wind turbine is mounted at the lower entry to the tower. When solar radiation heats the ground through the glass roof, ascending warm air is guided to the center and into the tower. A solar tower that can generate electricity using a simple structure that enables easy and less costly maintenance has considerable advantages. However, conversion efficiency from sunshine energy to mechanical turbine energy is very low. Aiming to improve this efficiency, the research project developed a diffuser-type tower instead of a cylindrical tower, and investigated a suitable diffuser shape for practical use. After changing the tower height and diffuser open angle, with a temperature difference between the ambient air aloft and within the collector, various diffuser tower shapes were tested by laboratory experiments and numerical analyses. As a result, it was found that a diffuser tower with a semi-open angle of 4° is an optimal shape, producing the fastest updraft at each temperature difference in both the laboratory experiments and numerical analyses. The relationships between thermal updraft speed and temperature difference and/or tower height were confirmed. It was found that the thermal updraft velocity is proportional to the square root of the tower height and/or temperature difference.

  18. Wind Climate Analyses for a 61-M Tower in the Southeast

    International Nuclear Information System (INIS)

    Weber, A.H.

    2003-01-01

    The Savannah River Technology Center's (SRTC) Atmospheric Technologies Group (ATG) has operated nine 61-m tower sites including the Central Climatology (CC) tower which is located near the center of the Savannah River Site (SRS) since 1985. Data from the weather instruments on this tower have provided answers to questions involving risk analyses, dose studies, forecast verifications, and wind/temperature conditions during extreme events and planned tests. Most recently, data from these towers are being used for initial and boundary conditions for computationally intensive numerical simulations using mesoscale forecasting models that are run on a three-hourly basis by ATG for SRS and the surrounding vicinity. We found that a series of wind roses based on relatively short time scales (from two weeks to one hour) were a convenient method to depict the predominant wind speeds and directions at anemometer sites in the Southeast operated by the NWS. That report also revealed some interesting spatial and temporal relationships among thirteen NWS stations in the Carolinas, Georgia, and Florida. Our study here will focus on the CC tower to show changes in the wind speed and direction distributions with height during diurnal and annual cycles. This study will concentrate on mean wind speed and direction statistics

  19. Dwelling towers of Czech castles

    Czech Academy of Sciences Publication Activity Database

    Durdík, Tomáš

    2009-01-01

    Roč. 63, - (2009), s. 139-150 ISSN 1875-2896. [Meeting of Europa Nostra Scientific Council /44./. Kilkenny, 27.09.2008-02.10.2008] Institutional research plan: CEZ:AV0Z80020508 Keywords : castle * castellology * dwelling tower * donjon * keep * medieval archaeology * architecture * Bohemia * Middle Ages Subject RIV: AC - Archeology, Anthropology, Ethnology

  20. An exergy analysis on the performance of a counterflow wet cooling tower

    International Nuclear Information System (INIS)

    Muangnoi, Thirapong; Asvapoositkul, Wanchai; Wongwises, Somchai

    2007-01-01

    Cooling towers are used to extract waste heat from water to atmospheric air. An energy analysis is usually used to investigate the performance characteristics of cooling tower. However, the energy concept alone is insufficient to describe some important viewpoints on energy utilization. In this study, an exergy analysis is used to indicate exergy and exergy destruction of water and air flowing through the cooling tower. Mathematical model based on heat and mass transfer principle is developed to find the properties of water and air, which will be further used in exergy analysis. The model is validated against experimental data. It is noted from the results that the amount of exergy supplied by water is larger than that absorbed by air, because the system produces entropy. To depict the utilizable exergy between water and air, exergy of each working fluid along the tower are presented. The results show that water exergy decreases continuously from top to bottom. On the other hand, air exergy is expressed in terms of convective and evaporative heat transfer. Exergy of air via convective heat transfer initially loses at inlet and slightly recovers along the flow before leaving the tower. However, exergy of air via evaporative heat transfer is generally high and able to consume exergy supplied by water. Exergy destruction is defined as the difference between water exergy change and air exergy change. It reveals that the cooling processes due to thermodynamics irreversibility perform poorly at bottom and gradually improve along the height of the tower. The results show that the lowest exergy destruction is located at the top of the tower

  1. LaGuardia air traffic control tower.

    Science.gov (United States)

    2011-01-01

    To celebrate FAA and its LaGuardia Airport employees past, : present, and future this booklet outlines the airports history and accomplishments and includes copies of some of the photographs in the : air traffic control towers history g...

  2. Fire and forest meteorology

    Science.gov (United States)

    SA Ferguson; T.J. Brown; M. Flannigan

    2005-01-01

    The American Meteorological Society symposia series on Fire and Forest Meteorology provides biennial forums for atmospheric and fire scientists to introduce and discuss the latest and most relevant research on weather, climate and fire. This special issue highlights significant work that was presented at the Fifth Symposium in Orlando, Florida during 16-20 November...

  3. Dimensions of Air Traffic Control Tower Information Needs: From Information Requests to Display Design

    Science.gov (United States)

    Durso, Francis T.; Johnson, Brian R.; Crutchfield, Jerry M.

    2010-01-01

    In an effort to determine the information needs of tower air traffic controllers, instructors from the Federal Aviation Administration's Academy in Oklahoma City were asked to control traffic in a high-fidelity tower cab simulator. Information requests were made apparent by eliminating access to standard tower information sources. Instead,…

  4. Research Based on the Acoustic Emission of Wind Power Tower Drum Dynamic Monitoring Technology

    Science.gov (United States)

    Zhang, Penglin; Sang, Yuan; Xu, Yaxing; Zhao, Zhiqiang

    Wind power tower drum is one of the key components of the wind power equipment. Whether the wind tower drum performs safety directly affects the efficiency, life, and performance of wind power equipment. Wind power tower drum in the process of manufacture, installation, and operation may lead to injury, and the wind load and gravity load and long-term factors such as poor working environment under the action of crack initiation or distortion, which eventually result in the instability or crack of the wind power tower drum and cause huge economic losses. Thus detecting the wind power tower drum crack damage and instability is especially important. In this chapter, acoustic emission is used to monitor the whole process of wind power tower drum material Q345E steel tensile test at first, and processing and analysis tensile failure signal of the material. And then based on the acoustic emission testing technology to the dynamic monitoring of wind power tower drum, the overall detection and evaluation of the existence of active defects in the whole structure, and the acoustic emission signals collected for processing and analysis, we could preliminarily master the wind tower drum mechanism of acoustic emission source. The acoustic emission is a kind of online, efficient, and economic method, which has very broad prospects for work. The editorial committee of nondestructive testing qualification and certification of personnel teaching material of science and technology industry of national defense, "Acoustic emission testing" (China Machine Press, 2005.1).

  5. Restoration of the Serranos Towers in Valencia.

    Directory of Open Access Journals (Sweden)

    Camilla Mileto

    2003-12-01

    Full Text Available The recent restoration of the emblematic Serranos Towers carried out by an interdisciplinary team of specialists was an excuse to delve into the history and masonry of the towers, from their initial building and use as a prison to the restorations works practised in the 19th century and subsequent repairs. The cleaning of the walls permitted a direct study of the masonry, which provided a great deal of information that complemented the rigorous historical investigation. The maintenance scheme planned for the future is an interesting proposal, where good sense prevails over improvisation, so often a reality in the restoration of monuments today.

  6. Cooling tower water circuits with raceways

    International Nuclear Information System (INIS)

    Nicollet, G.

    1981-02-01

    Two physical models built at the National Hydraulics Laboratory in Chatou have led to the determination of the design of the works. This new design economizes 4 to 5 MW on pumping power for each cooling tower [fr

  7. Dry cooling towers - the Schmehausen example

    International Nuclear Information System (INIS)

    Weber, P.

    1977-01-01

    In a prototype, there are often problems which require special static, constructive, and assembling measures for their solution. In the case of the Schmehausen dry cooling tower, the demands on the assembling technology are particularly high. (orig.) [de

  8. Performance Evaluation on Transmission Tower-Line System with Passive Friction Dampers Subjected to Wind Excitations

    Directory of Open Access Journals (Sweden)

    Bo Chen

    2015-01-01

    Full Text Available The vibration control and performance evaluation on a transmission-tower line system by using friction dampers subjected to wind excitations are carried out in this study. The three-dimensional finite element (FE model of a transmission tower is firstly constructed. A two-dimensional lumped mass model of a transmission tower is developed for dynamic analysis. The analytical model of transmission tower-line system is proposed by taking the dynamic interaction between the tower and the transmission lines into consideration. The mechanical model of passive friction damper is presented by involving the effects of damper axial stiffness. The equation of motion of the transmission tower-line system incorporated with the friction dampers disturbed by wind excitations is established. A real transmission tower-line system is taken as an example to examine the feasibility and reliability of the proposed control approach. An extensive parameter study is carried out to find the optimal parameters of friction damper and to assess the effects of slipping force axial stiffness and hysteresis loop on control performance. The work on an example structure indicates that the application of friction dampers with optimal parameters could significantly reduce wind-induced responses of the transmission tower-line system.

  9. Alternative geometry for cylindrical natural draft cooling tower with higher cooling efficiency under crosswind condition

    International Nuclear Information System (INIS)

    Goodarzi, M.; Ramezanpour, R.

    2014-01-01

    Highlights: • Alternative cross sections for natural draft cooling tower were proposed. • Numerical solution was applied to study thermal and hydraulic performances. • Thermal and hydraulic performances were assessed by comparative parameters. • Cooling tower with elliptical cross section had better thermal performance under crosswind. • It could successfully used at the regions with invariant wind direction. - Abstract: Cooling efficiency of a natural draft dry cooling tower may significantly decrease under crosswind condition. Therefore, many researchers attempted to improve the cooling efficiency under this condition by using structural or mechanical facilities. In this article, alternative shell geometry with elliptical cross section is proposed for this type of cooling tower instead of usual shell geometry with circular cross section. Thermal performance and cooling efficiency of the two types of cooling towers are numerically investigated. Numerical simulations show that cooling tower with elliptical cross section improves the cooling efficiency compared to the usual type with circular cross section under high-speed wind moving normal to the longitudinal diameter of the elliptical cooling tower

  10. Experimental study on the thermal performance of a mechanical cooling tower with different drift eliminators

    International Nuclear Information System (INIS)

    Lucas, M.; Martinez, P.J.; Viedma, A.

    2009-01-01

    Cooling towers are equipment devices commonly used to dissipate heat from power generation units, water-cooled refrigeration, air conditioning and industrial processes. Water drift emitted from cooling towers is objectionable for several reasons, mainly due to human health hazards. It is common practice to fit drift eliminators to cooling towers in order to minimize water loss from the system. It is foreseeable that the characteristics of the installed drift eliminators, like their pressure drop, affect the thermal performance of the cooling tower. However, no references regarding this fact have been found in the reviewed bibliography. This paper studies the thermal performance of a forced draft counter-flow wet cooling tower fitted with different drift eliminators for a wide range of air and water mass flow rates. The data registered in the experimental set-up were employed to obtain correlations of the tower characteristic, which defines the cooling tower's thermal performance. The outlet water temperature predicted by these correlations was compared with the experimentally registered values obtaining a maximum difference of ±3%

  11. Influence of detergents on water drift in cooling towers

    Science.gov (United States)

    Vitkovicova, Rut

    An influence of detergents on the water drift from the cooling tower was experimentally investigated. For this experimental measurements was used a model cooling tower, especially an experimental aerodynamic line, which is specially designed for the measurement and monitoring of processes taking place around the eliminators of the liquid phase. The effect of different concentrations of detergent in the cooling water on the drift of water droplets from a commonly used type eliminator was observed with visualization methods.

  12. Optimization of cooling tower performance analysis using Taguchi method

    OpenAIRE

    Ramkumar Ramakrishnan; Ragupathy Arumugam

    2013-01-01

    This study discuss the application of Taguchi method in assessing maximum cooling tower effectiveness for the counter flow cooling tower using expanded wire mesh packing. The experiments were planned based on Taguchi’s L27 orthogonal array .The trail was performed under different inlet conditions of flow rate of water, air and water temperature. Signal-to-noise ratio (S/N) analysis, analysis of variance (ANOVA) and regression were carried out in order to determine the effects of process...

  13. Mapping carbon flux uncertainty and selecting optimal locations for future flux towers in the Great Plains

    Science.gov (United States)

    Gu, Yingxin; Howard, Daniel M.; Wylie, Bruce K.; Zhang, Li

    2012-01-01

    Flux tower networks (e. g., AmeriFlux, Agriflux) provide continuous observations of ecosystem exchanges of carbon (e. g., net ecosystem exchange), water vapor (e. g., evapotranspiration), and energy between terrestrial ecosystems and the atmosphere. The long-term time series of flux tower data are essential for studying and understanding terrestrial carbon cycles, ecosystem services, and climate changes. Currently, there are 13 flux towers located within the Great Plains (GP). The towers are sparsely distributed and do not adequately represent the varieties of vegetation cover types, climate conditions, and geophysical and biophysical conditions in the GP. This study assessed how well the available flux towers represent the environmental conditions or "ecological envelopes" across the GP and identified optimal locations for future flux towers in the GP. Regression-based remote sensing and weather-driven net ecosystem production (NEP) models derived from different extrapolation ranges (10 and 50%) were used to identify areas where ecological conditions were poorly represented by the flux tower sites and years previously used for mapping grassland fluxes. The optimal lands suitable for future flux towers within the GP were mapped. Results from this study provide information to optimize the usefulness of future flux towers in the GP and serve as a proxy for the uncertainty of the NEP map.

  14. Interception and retention of simulated cooling tower drift by vegetation

    International Nuclear Information System (INIS)

    Taylor, F.G. Jr.; Parr, P.D.

    1978-01-01

    A key issue concerning environmental impacts from cooling tower operation is the interception of drift by vegetation and the efficiency of plants in retaining the residue scavenged from the atmosphere. Chromated drift water, typical of the cooling towers of the Department of Energy's uranium enrichment facilities at Oak Ridge, Tennessee, was prepared using radio-labelled chromium. A portable aerosol generator was used to produce a spectrum of droplets with diameters (100 to 1300 μ) characteristic of cooling towers using state-of-the-art drift eliminators. Efficiency of interception by foliage varied according to leaf morphology with yellow poplar seedlings intercepting 72% of the deposition mass in contrast to 45% by loblolly pine and 24% by fescue grass. Retention patterns of intercepted deposition consisted of a short-time component (0 to 3 days) and a long-time component (3 to 63 days). Retention times, estimated from the regression equation of the long component, indicated that drift contamination from any deposition event may persist from between 8 and 12 weeks. In field situations adjacent to cooling towers, the average annual concentration of drift on vegetation at any distance remains relatively constant, with losses from weathering being compensated by chronic deposition

  15. DESCARTES AND THE METEOROLOGY OF THE WORLD

    Directory of Open Access Journals (Sweden)

    Patrick BRISSEY

    2012-11-01

    Full Text Available Descartes claimed that he thought he could deduce the assumptions of his Meteorology by the contents of the Discourse. He actually began the Meteorology with assumptions. The content of the Discourse, moreover, does not indicate how he deduced the assumptions of the Meteorology. We seem to be left in a precarious position. We can examine the text as it was published, independent of Descartes’ claims, which suggests that he incorporated a presumptive or hypothetical method. On the other hand, we can take Descartes’ claims as our guide and search for the epistemic foundations of the Meteorology independent of the Discourse. In this paper, I will pursue the latter route. My aim is to explain why, and how, Descartes thought that he had deduced the assumptions of the Meteorology. My interest, in this case, is solely Descartes’ physical foundation for the Meteorology, in the physics and physiology that resulted in Descartes’ explanation. With this aim, I provide an interpretation of Descartes’ World where many of its conclusions serve as evidence for the assumptions of the Meteorology. I provisionally conclude that Descartes thought that his World was the epistemic foundation for his Meteorology.

  16. Lloyd Berkner: Catalyst for Meteorology's Fabulous Fifties

    Science.gov (United States)

    Lewis, J. M.

    2002-05-01

    In the long sweep of meteorological history - from Aristotle's Meteorologica to the threshold of the third millennium - the 1950s will surely be recognized as a defining decade. The contributions of many individuals were responsible for the combination of vision and institution building that marked this decade and set the stage for explosive development during the subsequent forty years. In the minds of many individuals who were active during those early years, however, one name stands out as a prime mover par excellence: Lloyd Viel Berkner. On May 1, 1957, Berkner addressed the National Press Club. The address was entitled, "Horizons of Meteorology". It reveals Berkner's insights into meteorology from his position as Chairman of the Committee on Meteorology of the National Academy of Sciences, soon to release the path-breaking report, Research and Education in Meteorology (1958). The address also reflects the viewpoint of an individual deeply involved in the International Geophysical Year (IGY). It is an important footnote to meteorological history. We welcome this opportunity to profile Berkner and to discuss "Horizons of Meteorology" in light of meteorology's state-of-affairs in the 1950s and the possible relevance to Berkner's ideas to contemporary issues.

  17. A tower structured scintillator-lead photon calorimeter using a novel fiber optics readout system

    International Nuclear Information System (INIS)

    Fessler, H.; Freund, P.; Gebauer, J.; Glas, K.M.; Pretzl, K.P.; Seyboth, P.; Seyerlein, J.; Thevenin, J.C.

    1984-06-01

    Described is the construction and the performance of a tower structured scintillator-lead photon calorimeter using a novel fiber optics readout system. The calorimeter is divided into 9 individual towers. Each tower has a cross section of 5x5 cm 2 and consists of 60 layers of 2 mm lead plus 5 mm thick scintillator. The four sides of each tower are covered by thin acrylic sheets (1.5 mm thick) doped with a wavelength shifting material. The light produced in each scintillator plate is first converted in these sheets, then converted a second time in a set of polystyrene optical fibers (diameter 2 mm) which run longitudinally through the calorimeter along the corners of each tower. A small diameter photomultiplier was attached to the fibers at the back end of the calorimeter. The obtained energy resolution with incident electrons in the range of 0.25 - 5.0 GeV/c is sigma/E = 0.10/√E. The uniformity of response across the front face of each tower was measured. (orig.)

  18. Study on Remote Monitoring System of Crossing and Spanning Tangent Tower

    Science.gov (United States)

    Chen, Da-bing; Zhang, Nai-long; Zhang, Meng-ge; Wang, Ze-hua; Zhang, Yan

    2017-05-01

    In order to grasp the vibration state of overhead transmission line and ensure the operational security of transmission line, the remote monitoring system of crossing and spanning tangent tower was studied. By use of this system, the displacement, velocity and acceleration of the tower, and the local weather data are collected automatically, displayed on computer of remote monitoring centre through wireless network, real-time collection and transmission of vibration signals are realized. The applying results show that the system is excellent in reliability and accuracy and so on. The system can be used to remote monitoring of transmission tower of UHV power transmission lines and in large spanning areas.

  19. The GEWEX LandFlux project: evaluation of model evaporation using tower-based and globally gridded forcing data

    KAUST Repository

    McCabe, Matthew; Ershadi, Ali; Jimenez, C.; Miralles, Diego G.; Michel, D.; Wood, E. F.

    2016-01-01

    closely by GLEAM (0.68; 64 W m−2; 0.62), with values in parentheses representing the R2, RMSD and Nash–Sutcliffe efficiency (NSE), respectively. PM-Mu (0.51; 78 W m−2; 0.45) tended to underestimate fluxes, while SEBS (0.72; 101 W m−2; 0.24) overestimated values relative to observations. A focused analysis across specific biome types and climate zones showed considerable variability in the performance of all models, with no single model consistently able to outperform any other. Results also indicated that the global gridded data tended to reduce the performance for all of the studied models when compared to the tower data, likely a response to scale mismatch and issues related to forcing quality. Rather than relying on any single model simulation, the spatial and temporal variability at both the tower- and grid-scale highlighted the potential benefits of developing an ensemble or blended evaporation product for global-scale LandFlux applications. Challenges related to the robust assessment of the LandFlux product are also discussed.

  20. The GEWEX LandFlux project: evaluation of model evaporation using tower-based and globally gridded forcing data

    KAUST Repository

    McCabe, Matthew

    2016-01-26

    closely by GLEAM (0.68; 64 W m−2; 0.62), with values in parentheses representing the R2, RMSD and Nash–Sutcliffe efficiency (NSE), respectively. PM-Mu (0.51; 78 W m−2; 0.45) tended to underestimate fluxes, while SEBS (0.72; 101 W m−2; 0.24) overestimated values relative to observations. A focused analysis across specific biome types and climate zones showed considerable variability in the performance of all models, with no single model consistently able to outperform any other. Results also indicated that the global gridded data tended to reduce the performance for all of the studied models when compared to the tower data, likely a response to scale mismatch and issues related to forcing quality. Rather than relying on any single model simulation, the spatial and temporal variability at both the tower- and grid-scale highlighted the potential benefits of developing an ensemble or blended evaporation product for global-scale LandFlux applications. Challenges related to the robust assessment of the LandFlux product are also discussed.

  1. The GEWEX LandFlux project: evaluation of model evaporation using tower-based and globally-gridded forcing data

    KAUST Repository

    McCabe, Matthew

    2015-08-24

    −2; 0.62), with values in parenthesis representing the R2, RMSD and Nash-Sutcliffe Efficiency (NSE) and respectively. PM-Mu (0.51; 78 W m−2; 0.45) tended to underestimate fluxes, while SEBS (0.72; 101 W m−2; 0.24) overestimated values relative to observations. A focused analysis across specific biome types and climate zones showed considerable variability in the performance of all models, with no single model consistently able to outperform any other. Results also indicated that the global gridded data tended to reduce the performance for all of the studied models when compared to the tower data, likely a response to scale mismatch and issues related to forcing quality. Rather than relying on any single model simulation, the spatial and temporal variability at both the tower- and grid-scale highlighted the potential benefits of developing an ensemble or blended evaporation product for global scale LandFlux applications. Challenges related to the robust assessment of the LandFlux product are also discussed.

  2. The Transmission Channel Tower Identification and Landslide Disaster Monitoring Based on Insar

    Science.gov (United States)

    Li, G.; Tan, Q.; Xie, C.; Fei, X.; Ma, X.; Zhao, B.; Ou, W.; Yang, Z.; Wang, J.; Fang, H.

    2018-04-01

    The transmission distance of transmission lines is long, the line affected by the diversity of climate and topography of the corridors of transmission lines, differences in regional geological structure conditions, variability of rock and soil types, and the complexity of groundwater. Under the influence of extreme weather conditions (ice-covered, strong wind, etc.) and sudden geological disasters (such as mudslides, flash floods, earthquakes, etc.), catastrophic damage and basic deformation problems of the tower foundations are prone, and even tower collapse accidents occur in severe cases, which affect the safe operation of transmission lines. Monitoring the deformation of power transmission towers and surrounding grounds, it is critical to ensuring the normal operation of transmission lines by assessing and controlling potential risks in advance. In this paper, using ALOS-2 PALSAR radar satellite data, differential interferometry was used to monitor surface deformation near the Sichuan Jinsu line transmission channel. The analysis found that a significant landslide hazard was found near the transmission channel tower in Yibin-Zhaotong section of Jinsu, Sichuan Province, the cumulative deformation reaches 9cm. The results of this paper can provide new monitoring means for safety monitoring of transmission towers.

  3. An alkaline approach to treating cooling towers for control of Legionella pneumophila.

    Science.gov (United States)

    States, S J; Conley, L F; Towner, S G; Wolford, R S; Stephenson, T E; McNamara, A M; Wadowsky, R M; Yee, R B

    1987-08-01

    Earlier field and laboratory studies have shown that Legionella species survive and multiply in the pH range 5.5 to 9.2. Additionally, the technical feasibility of operating cooling towers at elevated alkalinities and pH has previously been documented by published guidelines. The guidelines indicate that these conditions facilitate corrosion control and favor chlorine persistence which enhances the effectiveness of continuous chlorination in biofouling control. This information suggests that control of Legionella species in cooling towers can be accomplished by operating the towers under alkaline conditions. To test this possibility, we collected water samples over a period of months from a hospital cooling tower. The samples were analyzed for a variety of chemical parameters. Subsamples were pasteurized and inoculated with non-agar-passaged Legionella pneumophila which had been maintained in tap water. Correlation of subsequent Legionella growth with corresponding pH and alkalinity values revealed statistically significant inverse associations. These data support the hypothesis that operating cooling towers outside of the optimal conditions for Legionella growth (e.g., at elevated alkalinities and a pH greater than 9) may be a useful approach to controlling growth in this habitat.

  4. Cost-benefit of the bubble tower concept as a containment passive safety system

    International Nuclear Information System (INIS)

    Iotti, R.C.; Bardach, H.; Shin, J.J.; Parnes, M.J.

    1994-01-01

    Containment system integrity for both PWRs and BWRs can be assured by passive measures highlighted the use of an accessory Bubble Tower. The utilization of the Bubble Tower precludes the possibility of containment overpressurization. From the thermodynamic standpoint, the Bubble Tower is simply water column of about 120 ft. height attached to the containment and connected to the air space above the suppression pool of a BWR, or a PWR In-containment Refueling Water Storage Tank. From the radiological protection standpoint, the Bubble Tower is a water column sufficient to effect decontamination factors of at least 100 for nuclide species other than the noble gases, and with the addition of organic solubilizers sufficient to effect decontamination factors of at least 10 iodides and at least 100 for other nuclide species. When containment steam or noncondensable gas passes through the Bubble Tower, a significant fraction of the radionuclides is absorbed by the water column. When a cost-benefit dose evaluation is performed relative to the utilization of a Bubble Tower, even under conditions where the dollars per man-rem is taken as $1000, the results are favorable. They are substantially more favorable when the dollars per man-rem is taken as $5000 or $10,000 as are the current trends. (author)

  5. Sea-water intake tower works for Hamaoka Nuclear Power Station No. 2 Plant

    Energy Technology Data Exchange (ETDEWEB)

    Sataki, N; Sugaya, Y; Sugimoto, T [Chubu Electric Power Co. Inc., Nagoya (Japan)

    1976-01-01

    It was determined to adopt tunnel system based on the conclusion of negotiation with local people, specifically fishermen, for the sea water intake arrangement in Hamaoka Nuclear Power Station. The main factors for determining the location of the intake tower included marine conditions such as waves and littoral sand drift, and the sea-bottom topographic features and geology of tunnel route, for which field examination, hydraulic experiments and the research and investigation on the method of construction were carried out. These results in the No.2 tower installation at the point 65 m to the east of the No.1 tower. The construction of the tower is described on the manufacture and conveyance of steel caisson, land works at Omaezaki and temporary assembly works on the sea. Then the details of tower installation and the works on site are reported. Fortunately the difficult sea works have been satisfactorily completed earlier than planned, without any accident. The construction facilities utilizing a pilot tunnel seem to have made the better achievement than expected. In spite of the results, the lifting up, off-shore conveyance, and installation of the intake tower caisson, a superheavy structure of weighting up to total 2900 ton, were critical works.

  6. Sea-water intake tower works for Hamaoka Nuclear Power Station No. 2 Plant

    International Nuclear Information System (INIS)

    Satake, Norimoto; Sugaya, Yoshinobu; Sugimoto, Tadao

    1976-01-01

    It was determined to adopt tunnel system based on the conclusion of negotiation with local people, specifically fishermen, for the sea water intake arrangement in Hamaoka Nuclear Power Station. The main factors for determining the location of the intake tower included marine conditions such as waves and littoral sand drift, and the sea-bottom topographic features and geology of tunnel route, for which field examination, hydraulic experiments and the research and investigation on the method of construction were carried out. These results in the No.2 tower installation at the point 65 m to the east of the No.1 tower. The construction of the tower is described on the manufacture and conveyance of steel caisson, land works at Omaezaki and temporary assembly works on the sea. Then the details of tower installation and the works on site are reported. Fortunately the difficult sea works have been satisfactorily completed earlier than planned, without any accident. The construction facilities utilizing a pilot tunnel seem to have made the better achievement than expected. In spite of the results, the lifting up, off-shore conveyance, and installation of the intake tower caisson, a superheavy structure of weighting up to total 2900 ton, were critical works. (Wakatsuki, Y.)

  7. Evaluating the Effectiveness of Wildlife Detection and Observation Technologies at a Solar Power Tower Facility.

    Science.gov (United States)

    Diehl, Robert H; Valdez, Ernest W; Preston, Todd M; Wellik, Michael J; Cryan, Paul M

    2016-01-01

    Solar power towers produce electrical energy from sunlight at an industrial scale. Little is known about the effects of this technology on flying animals and few methods exist for automatically detecting or observing wildlife at solar towers and other tall anthropogenic structures. Smoking objects are sometimes observed co-occurring with reflected, concentrated light ("solar flux") in the airspace around solar towers, but the identity and origins of such objects can be difficult to determine. In this observational pilot study at the world's largest solar tower facility, we assessed the efficacy of using radar, surveillance video, and insect trapping to detect and observe animals flying near the towers. During site visits in May and September 2014, we monitored the airspace surrounding towers and observed insects, birds, and bats under a variety of environmental and operational conditions. We detected and broadly differentiated animals or objects moving through the airspace generally using radar and near solar towers using several video imaging methods. Video revealed what appeared to be mostly small insects burning in the solar flux. Also, we occasionally detected birds flying in the solar flux but could not accurately identify birds to species or the types of insects and small objects composing the vast majority of smoking targets. Insect trapping on the ground was somewhat effective at sampling smaller insects around the tower, and presence and abundance of insects in the traps generally trended with radar and video observations. Traps did not tend to sample the larger insects we sometimes observed flying in the solar flux or found dead on the ground beneath the towers. Some of the methods we tested (e.g., video surveillance) could be further assessed and potentially used to automatically detect and observe flying animals in the vicinity of solar towers to advance understanding about their effects on wildlife.

  8. Evaluating the effectiveness of wildlife detection and observation technologies at a solar power tower facility

    Science.gov (United States)

    Diehl, Robert H.; Valdez, Ernest W.; Preston, Todd M.; Wellik, Mike J.; Cryan, Paul

    2016-01-01

    Solar power towers produce electrical energy from sunlight at an industrial scale. Little is known about the effects of this technology on flying animals and few methods exist for automatically detecting or observing wildlife at solar towers and other tall anthropogenic structures. Smoking objects are sometimes observed co-occurring with reflected, concentrated light (“solar flux”) in the airspace around solar towers, but the identity and origins of such objects can be difficult to determine. In this observational pilot study at the world’s largest solar tower facility, we assessed the efficacy of using radar, surveillance video, and insect trapping to detect and observe animals flying near the towers. During site visits in May and September 2014, we monitored the airspace surrounding towers and observed insects, birds, and bats under a variety of environmental and operational conditions. We detected and broadly differentiated animals or objects moving through the airspace generally using radar and near solar towers using several video imaging methods. Video revealed what appeared to be mostly small insects burning in the solar flux. Also, we occasionally detected birds flying in the solar flux but could not accurately identify birds to species or the types of insects and small objects composing the vast majority of smoking targets. Insect trapping on the ground was somewhat effective at sampling smaller insects around the tower, and presence and abundance of insects in the traps generally trended with radar and video observations. Traps did not tend to sample the larger insects we sometimes observed flying in the solar flux or found dead on the ground beneath the towers. Some of the methods we tested (e.g., video surveillance) could be further assessed and potentially used to automatically detect and observe flying animals in the vicinity of solar towers to advance understanding about their effects on wildlife.

  9. Influence of detergents on water drift in cooling towers

    Directory of Open Access Journals (Sweden)

    Vitkovicova Rut

    2017-01-01

    Full Text Available An influence of detergents on the water drift from the cooling tower was experimentally investigated. For this experimental measurements was used a model cooling tower, especially an experimental aerodynamic line, which is specially designed for the measurement and monitoring of processes taking place around the eliminators of the liquid phase. The effect of different concentrations of detergent in the cooling water on the drift of water droplets from a commonly used type eliminator was observed with visualization methods.

  10. Study on a new meteorological sampling scheme developed for the OSCAAR code system

    International Nuclear Information System (INIS)

    Liu Xinhe; Tomita, Kenichi; Homma, Toshimitsu

    2002-03-01

    One important step in Level-3 Probabilistic Safety Assessment is meteorological sequence sampling, on which the previous studies were mainly related to code systems using the straight-line plume model and more efforts are needed for those using the trajectory puff model such as the OSCAAR code system. This report describes the development of a new meteorological sampling scheme for the OSCAAR code system that explicitly considers population distribution. A group of principles set for the development of this new sampling scheme includes completeness, appropriate stratification, optimum allocation, practicability and so on. In this report, discussions are made about the procedures of the new sampling scheme and its application. The calculation results illustrate that although it is quite difficult to optimize stratification of meteorological sequences based on a few environmental parameters the new scheme do gather the most inverse conditions in a single subset of meteorological sequences. The size of this subset may be as small as a few dozens, so that the tail of a complementary cumulative distribution function is possible to remain relatively static in different trials of the probabilistic consequence assessment code. (author)

  11. Investigation of Airflow Patterns in a New Design of Wind Tower with a Wetted Surface

    Directory of Open Access Journals (Sweden)

    Madjid Soltani

    2018-04-01

    Full Text Available Passive cooling systems, such as wind towers, can help to reduce energy consumption in buildings and at the same time reduce greenhouse gas (GHG emissions. Wind towers can naturally ventilate buildings and also can create enhanced thermal comfort for occupants during the warm months. This study proposes a modern wind tower design with a moistened pad. The new design includes a fixed column, a rotating and movable head, an air opening with a screen, and two windows at the end of the column. The wind tower can be installed on roof-tops to take advantage of ambient airflow. The wind tower’s head can be controlled manually or automatically to capture optimum wind velocity based on desired thermal condition. To maximize its performance, a small pump was considered to circulate and spray water on an evaporative cooling pad. A computational fluid dynamics (CFD simulation of airflow around and inside the proposed wind tower is conducted to analyze the ventilation performance of this new design of wind tower. Thereby, the velocity, total pressure, and pressure coefficient distributions around and within the wind tower for different wind velocities are examined. The simulation results illustrate that the new wind tower design with a moistened pad can be a reasonable solution to improve naturally the thermal comfort of buildings in hot and dry climates.

  12. Optimization of Structural Design for Sustainable Construction of Transmission Tower Based on Topographical Algorithm

    International Nuclear Information System (INIS)

    Muda, Zakaria Che; Thiruchelvam, Sivadass; Mustapha, Kamal Nasharuddin; Omar, Rohayu Che; Usman, Fathoni; Alam, Md Ashrafu

    2013-01-01

    Optimization of transmission tower structures is traditionally based on either optimization of members sizes with fixed topographical shape or based on structural analysis modelling strategies without taking cognizance of fabrication and constructability issue facing the contractors . This paper look into an integrated optimum design approach strategies whereby size, shape and topology are combined together with the fabrication issues in the construction of the transmission tower. The topographical algorithm is based on changing the inclination degree of the legs of the tower at first with optimum individual members sizing and later rationalized member sizes are performed through member groupings for the ease fabrication and construction of the transmission tower. The optimum weight using topographical algorithm obtained for the transmission tower is 10,924 kg for singular members and 18,430 kg for element grouping at 10° inclination angle.

  13. An integrated reliability-based design optimization of offshore towers

    International Nuclear Information System (INIS)

    Karadeniz, Halil; Togan, Vedat; Vrouwenvelder, Ton

    2009-01-01

    After recognizing the uncertainty in the parameters such as material, loading, geometry and so on in contrast with the conventional optimization, the reliability-based design optimization (RBDO) concept has become more meaningful to perform an economical design implementation, which includes a reliability analysis and an optimization algorithm. RBDO procedures include structural analysis, reliability analysis and sensitivity analysis both for optimization and for reliability. The efficiency of the RBDO system depends on the mentioned numerical algorithms. In this work, an integrated algorithms system is proposed to implement the RBDO of the offshore towers, which are subjected to the extreme wave loading. The numerical strategies interacting with each other to fulfill the RBDO of towers are as follows: (a) a structural analysis program, SAPOS, (b) an optimization program, SQP and (c) a reliability analysis program based on FORM. A demonstration of an example tripod tower under the reliability constraints based on limit states of the critical stress, buckling and the natural frequency is presented.

  14. An integrated reliability-based design optimization of offshore towers

    Energy Technology Data Exchange (ETDEWEB)

    Karadeniz, Halil [Faculty of Civil Engineering and Geosciences, Delft University of Technology, Delft (Netherlands)], E-mail: h.karadeniz@tudelft.nl; Togan, Vedat [Department of Civil Engineering, Karadeniz Technical University, Trabzon (Turkey); Vrouwenvelder, Ton [Faculty of Civil Engineering and Geosciences, Delft University of Technology, Delft (Netherlands)

    2009-10-15

    After recognizing the uncertainty in the parameters such as material, loading, geometry and so on in contrast with the conventional optimization, the reliability-based design optimization (RBDO) concept has become more meaningful to perform an economical design implementation, which includes a reliability analysis and an optimization algorithm. RBDO procedures include structural analysis, reliability analysis and sensitivity analysis both for optimization and for reliability. The efficiency of the RBDO system depends on the mentioned numerical algorithms. In this work, an integrated algorithms system is proposed to implement the RBDO of the offshore towers, which are subjected to the extreme wave loading. The numerical strategies interacting with each other to fulfill the RBDO of towers are as follows: (a) a structural analysis program, SAPOS, (b) an optimization program, SQP and (c) a reliability analysis program based on FORM. A demonstration of an example tripod tower under the reliability constraints based on limit states of the critical stress, buckling and the natural frequency is presented.

  15. Performance Evaluation of a Mechanical Draft Cross Flow Cooling Towers Employed in a Subtropical Region

    Science.gov (United States)

    Muthukumar, Palanisamy; Naik, Bukke Kiran; Goswami, Amarendra

    2018-02-01

    Mechanical draft cross flow cooling towers are generally used in a large-scale water cooled condenser based air-conditioning plants for removing heat from warm water which comes out from the condensing unit. During this process considerable amount of water in the form of drift (droplets) and evaporation is carried away along with the circulated air. In this paper, the performance evaluation of a standard cross flow induced draft cooling tower in terms of water loss, range, approach and cooling tower efficiency are presented. Extensive experimental studies have been carried out in three cooling towers employed in a water cooled condenser based 1200 TR A/C plant over a period of time. Daily variation of average water loss and cooling tower performance parameters have been reported for some selected days. The reported average water loss from three cooling towers is 4080 l/h and the estimated average water loss per TR per h is about 3.1 l at an average relative humidity (RH) of 83%. The water loss during peak hours (2 pm) is about 3.4 l/h-TR corresponding to 88% of RH and the corresponding efficiency of cooling towers varied between 25% and 45%.

  16. A construction method of reinforced-concrete very high stacks and natural draft cooling towers

    International Nuclear Information System (INIS)

    Miyamoto, Takao; Hosokawa, Osamu

    1978-01-01

    The new Shimizu flex-lip system was developed by the Shimizu Construction Co., Ltd. for constructing very high (about 200 m) towers made of reinforced concrete. Utilizing this system, towers of any shape, circular, triangular, square and polygonal, can be constructed. The wall thickness can be varied from 200 mm to 1 m. The diameter of towers can be enlarged from 3 m to any valve and the inclination of tower walls can be designed in any way between +1/5 and -1/5. The advantage of this system is to use the jack down mechanism, to test concrete strength without sampling, to reduce the connections of reinforcing steel bars and to adopt the continuous, and to use automatic measuring system using laser for checking up positional error. The design and analysis of high tower structures were systemized and automated with the development of the flex-lip construction method. The several past records of having applied this method to industrial areas are shown. As for natural draft cooling towers, the Shimizu jump-up system has been studied for the cooling water capacity of 60,000 m 3 /h. The towers are 120 m high, 110 m in diameter at the bottom and 65 m in diameter at the top. The advantage of this construction method, the plan of concrete jump-up and the construction test are explained. (Nakai, Y.)

  17. Design of a redundant meteorological station for a BWR reactor

    International Nuclear Information System (INIS)

    Ramirez S, R.; Celis del Angel, L.; Bucio, F.; Rivero, T.; Palacios, J.

    2008-01-01

    In this work the design of a meteorological station for a reactor type BWR is proposed. Two independent channels of data acquisition that allow him to have a bigger readiness is exposed. It is incorporate sensors without mobile parts to measure speed, wind direction and pluvial precipitation. It also counts, with sensors of global solar radiation, net radiation, barometric pressure, relative humidity and ambient temperature; with them they are possible to be calculated, moreover, other variables as temperature differential, dew point and atmospheric stability. The sensors are placed on a tower to different heights and send their information (each second) to a local registration system, the one which in turn, it remits the data to the monitoring office so that a computer is linked with the system, display and management the information in real time and automatic way. The redundant structure allows that in the event of maintenance the data acquisition is not interrupted, even if the information is transferred to another place. In all the station sections it is used protocols of standard communication to allow that a great quantity of devices can be connected without major problem. The above-mentioned would allow to the operators in the control room to have reliable information during the whole time of the reactor operation. (Author)

  18. Acoustic emission monitoring of medieval towers considered as sensitive earthquake receptors

    Directory of Open Access Journals (Sweden)

    A. Carpinteri

    2007-01-01

    Full Text Available Many ancient masonry towers are present in Italian territory. In some cases these structures are at risk on account of the intensity of the stresses they are subjected to due to the high level of regional seismicity. In order to preserve this inestimable cultural heritage, a sound safety assessment should take into account the evolution of damage phenomena. In this connection, acoustic emission (AE monitoring can be highly effective. This study concerns the structural stability of three medieval towers rising in the centre of Alba, a characteristic town in Piedmont (Italy. During the monitoring period a correlation between peaks of AE activity in the masonry of these towers and regional seismicity was found. Earthquakes always affect structural stability. Besides that, the towers behaved as sensitive earthquake receptors. Here a method to correlate bursts of AE activity in a masonry building and regional seismicity is proposed. In particular, this method permits to identify the premonitory signals that precede a catastrophic event on a structure, since, in most cases, these warning signs can be captured well in advance.

  19. Influence of stainless steel Internals on Corrosion of tower wall materials

    Science.gov (United States)

    Chen, Bing; Ren, Ke

    2017-12-01

    In view of the galvanic corrosion of the tower wall material in the tower of a refinery atmospheric vacuum distillation unit, the electrochemical behavior of Q345R steel, stainless steel (201, 304 cold-rolled plate, 304 hot rolled plate and 316L) in 3.5%NaCl solution was studied by electrochemical method. The results show that the corrosion potential of Q345R is much lower than that of stainless steel, and the corrosion rate of Q345R is higher than that of stainless steel. As the anode is etched as the anode corrosion, the anode polarizability of stainless steel shows strong polarization ability, which is anodic polarization control, and Q345R is anode Active polarization control; Q345R / 201 galvanic pair may be the most serious corrosion, and Q345R/316L galvanic couple may be relatively slight. Therefore, in the actual production of tower equipment, material design or tower to upgrade the replacement, it are recommended to use the preferred anode and cathode potential difference with the use of materials.

  20. Comparative assessment of anti-sway control strategy for tower crane system

    Science.gov (United States)

    Samin, Reza Ezuan; Mohamed, Zaharuddin

    2017-09-01

    Tower crane is also known as rotary crane and widely used in constructions due to limited human capability to carry the various types of load at the construction site. In general crane is used for the purpose of loading and unloading heavy material from one place to another. However, in order to transfer the material in minimum time from one location to another, swaying of the payload will occur. Hence, this research presents the investigation of tower crane system which mainly focusing on the swaying angle of the payload by implementing conventional and intelligent controllers. Its mathematical modeling is developed using the Newton's Second Law and simulation is done within the MATLAB/Simulink environment. Simulation results are presented in cart trajectory capability and payload sway angle reduction. A comparative assessment between conventional controller and intelligent controller for the tower crane system are presented and discussed. Furthermore, the effect of various rope length and payload mass of the tower crane system to the performance of trajectory capability and sway angle reduction are also presented and discussed.

  1. Dry cooling tower operating experience in the LOFT reactor

    International Nuclear Information System (INIS)

    Hunter, J.A.

    1980-01-01

    A dry cooling tower has been uniquely utilized to dissipate heat generated in a small experimental pressurized water nuclear reactor. Operational experience revealed that dry cooling towers can be intermittently operated with minimal wind susceptibility and water hammer occurrences by cooling potential steam sources after a reactor scram, by isolating idle tubes from the external atmosphere, and by operating at relatively high pressures. Operating experience has also revealed that tube freezing can be minimized by incorporating the proper heating and heat loss prevention features

  2. Cooling tower drift: experiment design for comprehensive case study

    International Nuclear Information System (INIS)

    Laulainen, N.S.

    1978-01-01

    A drift experiment program to develop a data base which can be used for validation of drift deposition models has been formulated. The first field effort is designed for a suitable mechanical-draft cooling tower to be selected after site visits have been conducted. The discussion here demonstrates the importance of characterizing the droplet size spectrum emitted from the tower and to accurately account for droplet evaporation, because the downwind droplet deposition patterns and near-surface airborne concentrations are extremely sensitive to these parameters

  3. Mathematical problems in meteorological modelling

    CERN Document Server

    Csomós, Petra; Faragó, István; Horányi, András; Szépszó, Gabriella

    2016-01-01

    This book deals with mathematical problems arising in the context of meteorological modelling. It gathers and presents some of the most interesting and important issues from the interaction of mathematics and meteorology. It is unique in that it features contributions on topics like data assimilation, ensemble prediction, numerical methods, and transport modelling, from both mathematical and meteorological perspectives. The derivation and solution of all kinds of numerical prediction models require the application of results from various mathematical fields. The present volume is divided into three parts, moving from mathematical and numerical problems through air quality modelling, to advanced applications in data assimilation and probabilistic forecasting. The book arose from the workshop “Mathematical Problems in Meteorological Modelling” held in Budapest in May 2014 and organized by the ECMI Special Interest Group on Numerical Weather Prediction. Its main objective is to highlight the beauty of the de...

  4. Legionnaires' Disease Outbreaks and Cooling Towers, New York City, New York, USA.

    Science.gov (United States)

    Fitzhenry, Robert; Weiss, Don; Cimini, Dan; Balter, Sharon; Boyd, Christopher; Alleyne, Lisa; Stewart, Renee; McIntosh, Natasha; Econome, Andrea; Lin, Ying; Rubinstein, Inessa; Passaretti, Teresa; Kidney, Anna; Lapierre, Pascal; Kass, Daniel; Varma, Jay K

    2017-11-01

    The incidence of Legionnaires' disease in the United States has been increasing since 2000. Outbreaks and clusters are associated with decorative, recreational, domestic, and industrial water systems, with the largest outbreaks being caused by cooling towers. Since 2006, 6 community-associated Legionnaires' disease outbreaks have occurred in New York City, resulting in 213 cases and 18 deaths. Three outbreaks occurred in 2015, including the largest on record (138 cases). Three outbreaks were linked to cooling towers by molecular comparison of human and environmental Legionella isolates, and the sources for the other 3 outbreaks were undetermined. The evolution of investigation methods and lessons learned from these outbreaks prompted enactment of a new comprehensive law governing the operation and maintenance of New York City cooling towers. Ongoing surveillance and program evaluation will determine if enforcement of the new cooling tower law reduces Legionnaires' disease incidence in New York City.

  5. Structural inspection and wind analysis of redwood cooling towers at the Portsmouth Gaseous Diffusion Plant

    International Nuclear Information System (INIS)

    Chung, T.; Solack, T.; Hortel, J.

    1991-01-01

    As part of the plant upgrade program, structural analyses and field inspections were performed on four redwood cooling towers at the DOE Portsmouth gaseous diffusion plant located in Piketon, Ohio. The cooling towers are categorized as important hazard facilities. The loadings are derived from UCRL-15910 according to the pertinent hazard category. In addition to the seismic and wind loadings, the wood cooling towers are constantly subject to adverse environmental effects such as elevated temperature, chemical attack, icing and snow load, and motor vibrations. A thorough structural evaluation for all load combinations was performed for each of the cooling towers based on the structural code requirements of the Cooling Tower Institute and National Forest Products Association. Most stress criteria are unique for the redwood material. This evaluation was performed using finite element techniques on the global structural integrity and supplemented by hand calculations on the individual connection joints. Overloaded wood structural members and joints are identified by the analysis. The rectangular tower structure sits on a concrete basin that span across 60 ft by 200 ft. A major part of the cooling towers upgrading program involved field inspections of the individual cells of each tower. The primary purpose of these inspections was to identify any existing structural damage or deficiencies such as failed members, degraded wood, and deficiencies resulting from poor construction practice. Inspection of 40 cells identified some generic deficiencies that mostly are consistent with the analytical finding. Based on the analysis, some effective but inexpensive upgrading techniques were developed and recommended to bring the cooling towers into compliance with current DOE requirements

  6. Tall tower landscape scale N2O flux measurements in a Danish agricultural and urban, coastal area

    Science.gov (United States)

    Ibrom, Andreas; Lequy, Émeline; Loubet, Benjamin; Pilegaard, Kim; Ambus, Per

    2015-04-01

    eastern coastline of the Roskilde fjord on the Danish island Zealand. The tower is surrounded by the fjord, by agricultural area, forests and, in the South by the urban area of the City of Roskilde. The City of Roskilde operates a waste incinerator and a waste water treatment plant, which drains treated waste water into the fjord. The level of the measured flux values was generally relatively low. Based on the clear definition of the lag time between N2O concentrations and the vertical wind speed, fluxes were measureable over larger periods. The fluxes showed clear directional relationships indicating their large spatial and temporal variability in the landscape. Footprint calculations were performed to attribute source areas to the measured fluxes ...(Kormann and Meixner, 2001; Neftel et al., 2008). The footprint of the flux measurement included areas between 200 m and several kilometres distance from the tower. A preliminary approach was developed to generate monthly maps of N2O fluxes around the tower. Here we present the results from the first seven months of flux measurements. Based on these results we discuss the potential and the limitations of tall tower eddy covariance measurements to estimate maps of N2O fluxes and the integral value of the landscape N2O flux. Acknowledgements: This work was funded by the EU-FP7 InGOS project. We thank Ebba Dellwik (Technical University of Denmark) for providing sonic anemometer data. References: Kormann, R. and Meixner, F.X., 2001. An Analytical Footprint Model For Non-Neutral Stratification. Boundary-Layer Meteorology, 99(2): 207-224. Neftel, A., Spirig, C. and Ammann, C., 2008. Application and test of a simple tool for operational footprint evaluations. Environmental Pollution, 152(3): 644-652.

  7. Distance protection of multiple-circuit shared tower transmission lines with different voltages

    DEFF Research Database (Denmark)

    Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2017-01-01

    combined faults, being advised to increase the resistive limit of the protection zone, if the network has lower short-circuit power. It is recommended to assure that the fault can only happen for cases where the faulted phase from the higher voltage level leads the faulted phase from the lower voltage......Multiple-circuit transmission lines combining different voltage levels in one tower present extra challenges when setting a protection philosophy, as faults between voltage levels are possible. In this study, the fault loop impedance of combined faults is compared with the fault loop impedance......-phase-to-ground faults. It is also demonstrated that the fault loop impedance of combined faults is more resistive, when compared with equivalent single-phase-to-ground faults. It is concluded that the settings used to protect a line against single-phase-to-ground faults are capable of protecting the line against...

  8. Continuous measurements of methane from a tower network over Siberia

    International Nuclear Information System (INIS)

    Sasakawa, M.; Machida, T.; Saeki, T.; Koyama, Y.; Maksyutov, S.; Shimoyama, K.; Tsuda, N.; Suto, H.; Arshinov, M.; Davydov, D.; Fofonov, A.; Krasnov, O.

    2010-01-01

    We have been conducting continuous measurements of Methane (CH 4 ) concentration from an expanding network of towers (JR-STATION: Japan-Russia Siberian Tall Tower Inland Observation Network) located in taiga, steppe and wetland biomes of Siberia since 2004. High daytime means (>2000 ppb) observed simultaneously at several towers during winter, together with in situ weather data and NCEP/NCAR reanalysis data, indicate that high pressure systems caused CH 4 accumulation at subcontinental scale due to the widespread formation of an inversion layer. Daytime means sometimes exceeded 2000 ppb, particularly in the summer of 2007 when temperature and precipitation rates were anomalously high over West Siberia, which implies that CH 4 emission from wetlands were exceptionally high in 2007. Many hot spots detected by MODIS in the summer of 2007 illustrate that the contribution of biomass burning also cannot be neglected. Daytime mean CH 4 concentrations from the Siberian tower sites were generally higher than CH 4 values reported at NOAA coastal sites in the same latitudinal zone, and the difference in concentrations between two sets of sites was reproduced with a coupled Eulerian-Lagrangian transport model. Simulations of emissions from different CH 4 sources suggested that the major contributor to variation switched from wetlands during summer to fossil fuel during winter.

  9. [Genotypic variability and persistence of Legionella pulsed-field gel electrophoresis patterns in 16 cooling towers in Shanghai, China].

    Science.gov (United States)

    Chen, Ming-liang; Wang, Gang-yi; Chen, Min; Zhou, Hai-jian; Shao, Zhu-jun; Zhang, Xi; Wu, Fan

    2010-07-01

    To investigate the genotypic characteristics and persistence of Legionella pulsed-field gel electrophoresis (PFGE) patterns in 16 air-conditioner cooling towers in six different public sites of Shanghai. From May to October, continuous sampling was operated once per month in 2007. Legionella strains isolated from the 16 cooling towers were confirmed by serological and latex agglutination. PFGE was applied for the fingerprinting of the isolates, while the cluster results of PFGE were analyzed by BioNumerics software. 131 strains of Legionella were isolated, including L. pneumophila, L. bozemanae, L. micdadei and L. anisa. 52 distinguishable PFGE patterns were differentiated among the 16 cooling towers, with 37 patterns were owned by just one cooling tower, which was not shared with other cooling towers, while 15 patterns were shared by more than 2 cooling towers. All the cooling towers had ≥ 2 PFGE patterns, while in 13 cooling towers the same PFGE patterns were recovered during the six months. From June to October of 2007, 18 strains of Legionella belonging to the PFGE pattern of LPAs.SH0078 were isolated continuously from 6 cooling towers. This study demonstrated great genotypic diversity and complexity of Legionella in cooling towers. Persistence of the PFGE patterns was observed in 81.25% of the cooling towers. The PFGE pattern of LPAs. SH0078 was distributed widely, suggesting it might be the dominate strain in Shanghai.

  10. The influence and analysis of natural crosswind on cooling characteristics of the high level water collecting natural draft wet cooling tower

    Science.gov (United States)

    Ma, Libin; Ren, Jianxing

    2018-01-01

    Large capacity and super large capacity thermal power is becoming the main force of energy and power industry in our country. The performance of cooling tower is related to the water temperature of circulating water, which has an important influence on the efficiency of power plant. The natural draft counter flow wet cooling tower is the most widely used cooling tower type at present, and the high cooling tower is a new cooling tower based on the natural ventilation counter flow wet cooling tower. In this paper, for high cooling tower, the application background of high cooling tower is briefly explained, and then the structure principle of conventional cooling tower and high cooling tower are introduced, and the difference between them is simply compared. Then, the influence of crosswind on cooling performance of high cooling tower under different wind speeds is introduced in detail. Through analysis and research, wind speed, wind cooling had little impact on the performance of high cooling tower; wind velocity, wind will destroy the tower inside and outside air flow, reducing the cooling performance of high cooling tower; Wind speed, high cooling performance of cooling tower has increased, but still lower than the wind speed.

  11. Desalination using spray tower and vapour compression refrigeration system

    International Nuclear Information System (INIS)

    Sathish Kumar, S.; Mani, A.

    2006-01-01

    A desalination system using a spray tower and Vapour Compression Refrigeration (VCR) system is proposed for obtaining fresh water from brackish water. In the spray tower, simultaneous heat and mass transfer take place between the brackish water and air, which results in the evaporation of the brackish water and humidification of the air. Fresh water is obtained from the humidified air by condensing the water vapour using a VCR system. Parametric studies were carried out to study the effect of various operational parameters on the fresh water production rate. (author)

  12. Meteorology Online.

    Science.gov (United States)

    Kahl, Jonathan D. W.

    2001-01-01

    Describes an activity to learn about meteorology and weather using the internet. Discusses the National Weather Service (NWS) internet site www.weather.gov. Students examine maximum and minimum daily temperatures, wind speed, and direction. (SAH)

  13. 78 FR 11146 - Utility Scale Wind Towers From the People's Republic of China: Antidumping Duty Order

    Science.gov (United States)

    2013-02-15

    ... DEPARTMENT OF COMMERCE International Trade Administration [A-570-981] Utility Scale Wind Towers...''), the Department is issuing an antidumping duty order on utility scale wind towers (``wind towers...) 482-3936, or (202) 482-4852, respectively. SUPPLEMENTARY INFORMATION: Background In accordance with...

  14. Epicurean Meteorology: Sources, method, scope and organization

    NARCIS (Netherlands)

    Bakker, F.A.

    2016-01-01

    In Epicurean Meteorology Frederik Bakker discusses the meteorology as laid out by Epicurus (341-270 BCE) and Lucretius (1st century BCE). Although in scope and organization their ideas are clearly rooted in the Peripatetic tradition, their meteorology sets itself apart from this tradition by its

  15. Effect of solar radiation on the performance of cross flow wet cooling tower in hot climate of Iran

    Science.gov (United States)

    Banooni, Salem; Chitsazan, Ali

    2016-11-01

    In some cities such as Ahvaz-Iran, the solar radiation is very high and the annual-mean-daily of the global solar radiation is about 17.33 MJ m2 d-1. Solar radiation as an external heat source seems to affect the thermal performance of the cooling towers. Usually, in modeling cooling tower, the effects of solar radiation are ignored. To investigate the effect of sunshade on the performance and modeling of the cooling tower, the experiments were conducted in two different states, cooling towers with and without sunshade. In this study, the Merkel's approach and finite difference technique are used to predict the thermal behavior of cross flow wet cooling tower without sunshade and the results are compared with the data obtained from the cooling towers with and without sunshade. Results showed that the sunshade is very efficient and it reduced the outlet water temperature, the approach and the water exergy of the cooling tower up to 1.2 °C, 15 and 1.1 %, respectively and increased the range and the efficiency of the cooling tower up to 29 and 37 %, respectively. Also, the sunshade decreased the error between the experimental data of the cooling tower with sunshade and the modeling results of the cooling tower without sunshade 1.85 % in average.

  16. Meteorological Summaries

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Multi-year summaries of one or more meteorological elements at a station or in a state. Primarily includes Form 1078, a United States Weather Bureau form designed...

  17. Hydroaerothermal investigations conducted in the USSR to justify the construction of large cooling towers

    International Nuclear Information System (INIS)

    Goncharov, V.V.

    1989-01-01

    The multi-purpose task of improving water cooling systems of thermal and nuclear power plants is aimed at the development of efficient designs of cooling towers and other types of industrial coolers which call for comprehensive scientific justification. Cooling towers of 60-70 thou m 3 /h capacity with a chimney height of 130 m and those of 80-100 thou m 3 /h capacity with a chimney height of 150 m were developed. For circulating water systems of large power plants the design of a counterflow chimney cooling tower of 180 thou m 3 /h capacity has been recently developed. At present the work is being conducted on developing a new three-cell cooling tower featuring high reliability, operational flexibility and cost-effectiveness of the design. This cooling tower, besides having higher operating reliability than the conventional one of circular shape, can ensure the commissioning, current repairs and overhauls of water cooling arrangements in a cell-wise sequence, i.e. without shutting down the power generating units. Laboratory and field investigations of the spray-type cooling towers having no packing (fill), studies on heat and mass exchanges processes, aerodynamics of droplet flows and new designs of sprayers made it possible to come to a conclusion that their cooling capacity can be substantially increased and brought up to the level of the cooling towers with film packings. The pilot cooling towers were designed according to the counterflow, crossflow and cross-counterflow schemes. The basic investigation method remains to be the experimental one. On the test rigs and aerodynamic models the heat and mass transfer and aerodynamic resistance coefficients are determined. These studies and subsequent calculations are based on the heat balance equation

  18. Medical Meteorology: the Relationship between Meteorological Parameters (Humidity, Rainfall, Wind, and Temperature and Brucellosis in Zanjan Province

    Directory of Open Access Journals (Sweden)

    Yousefali Abedini

    2016-06-01

    Full Text Available Background: Brucellosis (Malta fever is a major contagious zoonotic disease, with economic and public health importance. Methods To assess the effect of meteorological (temperature, rainfall, humidity, and wind and climate parameters on incidence of brucellosis, brucellosis distribution and meteorological zoning maps of Zanjan Province were prepared using Inverse Distance Weighting (IDW and Kriging technique in Arc GIS medium. Zoning maps of mean temperature, rainfall, humidity, and wind were compared to brucellosis distribution maps. Results: Correlation test showed no relationship between the mean number of patients with brucellosis and any of the four meteorological parameters. Conclusion: It seems that in Zanjan province there is no correlation between brucellosis and meteorological parameters.

  19. Technology and Meteorology. An Action Research Paper.

    Science.gov (United States)

    Taggart, Raymond F.

    Meteorology, the science of weather and weather conditions, has traditionally been taught via textbook and rote demonstration. This study was intended to determine to what degree utilizing technology in the study of meteorology improves students' attitudes towards science and to measure to what extent technology in meteorology increases…

  20. Emission of a natural-draught wet cooling tower and flow conditions at the brim of the cooling tower

    International Nuclear Information System (INIS)

    Baer, E.; Billet, W.; Dittrich, H.; Ernst, G.; Roller, W.; Wurz, D.

    1975-01-01

    Between July 1973 and September 1974, measurements were carried out around a natural-draught wet cooling tower during different weather conditions. The results of these measurements are to serve as basic material for the calculation of plume diffusion. (orig./TK) [de

  1. Acoustic results of the Boeing model 360 whirl tower test

    Science.gov (United States)

    Watts, Michael E.; Jordan, David

    1990-09-01

    An evaluation is presented for whirl tower test results of the Model 360 helicopter's advanced, high-performance four-bladed composite rotor system intended to facilitate over-200-knot flight. During these performance measurements, acoustic data were acquired by seven microphones. A comparison of whirl-tower tests with theory indicate that theoretical prediction accuracies vary with both microphone position and the inclusion of ground reflection. Prediction errors varied from 0 to 40 percent of the measured signal-to-peak amplitude.

  2. Load-Direction-Derived Support Structures for Wind Turbines: A Lattice Tower Concept and Preparations for Future Certifications: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Jonkman, Jason [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Damiani, Rick R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Struve, Achim [University of Applied Sciences Flensburg; Faber, Torsten [University of Applied Sciences Flensburg; Ummenhofer, Thomas [Karlsruhe Institute of Technology

    2017-11-07

    The call for more cost-effective and environmentally friendly tower concepts is motivated by tower costs [1] and tower CO2-emission contributions [2], which are high relative to the whole wind turbine system. The proposed rotatable tower concept with yaw bearing at the bottom instead of the top of the tower will provide beneficial economic and environmental impacts to the turbine system. This wind alignment capability indicates a load-direction-derived tower design. By combining this approach with a lattice concept, large material and cost savings for the tower can be achieved. This paper presents a way to analyze and verify the proposed design through aero-servo-elastic simulations, which make future certifications of rotatable tower concepts viable. For this reason, the state-of-the-art, open-source lattice-tower finite-element-method (FEM) module SubDyn [10], developed by the National Renewable Energy Laboratory, has been modified to account for arbitrary member cross-sections. Required changes in the beam element stiffness and mass matrix formulation took place according to an energy method [13]. All validated adaptions will be usable within the aero-servo-elastic simulation framework FAST and are also beneficial for other nonrotatable lattice structures.

  3. Counter flow induced draft cooling tower option for supercritical carbon dioxide Brayton cycle

    Energy Technology Data Exchange (ETDEWEB)

    Pidaparti, Sandeep R., E-mail: sandeep.pidaparti@gmail.com [Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, Atlanta, GA 30332 (United States); Moisseytsev, Anton; Sienicki, James J. [Argonne National Laboratory, 9700 South Cass Avenue, Argonne, IL 60439 (United States); Ranjan, Devesh, E-mail: devesh.ranjan@me.gatech.edu [Georgia Institute of Technology, George W. Woodruff School of Mechanical Engineering, Atlanta, GA 30332 (United States)

    2015-12-15

    Highlights: • A code was developed to investigate the various aspects of using cooling tower for S-CO{sub 2} Brayton cycles. • Cooling tower option to reject heat is quantitatively compared to the direct water cooling and dry air cooling options. • Optimum water conditions resulting in minimal plant capital cost per unit power consumption are calculated. - Abstract: A simplified qualitative analysis was performed to investigate the possibility of using counter flow induced draft cooling tower option to reject heat from the supercritical carbon dioxide Brayton cycle for advanced fast reactor (AFR)-100 and advanced burner reactor (ABR)-1000 plants. A code was developed to estimate the tower dimensions, power and water consumption, and to perform economic analysis. The code developed was verified against a vendor provided quotation and is used to understand the effect of ambient air and water conditions on the design of cooling tower. The calculations indicated that there exists optimum water conditions for given ambient air conditions which will result in minimum power consumption, thereby increasing the cycle efficiency. A cost-based optimization technique is used to estimate the optimum water conditions which will improve the overall plant economics. A comparison of different cooling options for the S-CO{sub 2} cycle indicated that the cooling tower option is a much more practical and economical option compared to the dry air cooling or direct water cooling options.

  4. Defense Meteorological Satellite Program (DMSP) Film

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The United States Air Force Defense Meteorological Satellite Program (DMSP) Operational Linescan System (OLS) is a polar orbiting meteorological sensor with two...

  5. Ecological impact of chloro-organics produced by chlorination of cooling tower waters

    International Nuclear Information System (INIS)

    Jolley, R.L.; Cumming, R.B.; Pitt, W.W.; Taylor, F.G.; Thompson, J.E.; Hartmann, S.J.

    1977-01-01

    Experimental results of the initial assessment of chlorine-containing compounds in the blowdown from cooling towers and the possible mutagenic activity of these compounds are reported. High-resolution liquid chromatographic separations were made on concentrates of the blowdown from the cooling tower at the High Flux Isotope Reactor (HFIR) and from the recirculating water system for the cooling towers at the Oak Ridge Gaseous Diffusion Plant (ORGDP), Oak Ridge, Tennessee. The chromatograms of chlorinated cooling waters contained numerous uv-absorbing and cerate-oxidizable constituents that are now being processed through a multicomponent identification procedure. Concentrates of the chlorinated waters are also being examined for mutagenic activity

  6. Modeling and characteristics analysis of hybrid cooling-tower-solar-chimney system

    International Nuclear Information System (INIS)

    Zou, Zheng; He, Suoying

    2015-01-01

    Highlights: • A 3-D model for hybrid cooling-tower-solar-chimney system is developed. • The inclusion of heat exchangers into solar chimney boosts the power output. • The huge jump in power output is at the expense of heat dissipation capacity. • The heat exchanger as second heat source has greater impact on system performance. - Abstract: The hybrid cooling-tower-solar-chimney system (HCTSC), combining solar chimney with natural draft dry cooling tower, generates electricity and dissipates waste heat for the coupled geothermal power plant simultaneously. Based on a developed 3-D model, performance comparisons between the HCTSC system, solar chimney and natural draft dry cooling tower were performed in terms of power output of turbine and heat dissipation capacity. Results show that compared to the traditional solar chimney with similar geometric dimensions, HCTSC system can achieve over 20 times increase in the power output of turbine. However, this huge jump in power output is at the expense of heat dissipation capacity, which may lead to the malfunction of the coupled thermal power plant. By increasing the heat transfer area of the heat exchanger, the HCTSC system can manage to recover its heat dissipation capacity

  7. Numerical simulation of shower cooling tower based on artificial neural network

    International Nuclear Information System (INIS)

    Qi Xiaoni; Liu Zhenyan; Li Dandan

    2008-01-01

    This study was prompted by the need to design towers for applications in which, due to salt deposition on the packing and subsequent blockage, the use of tower packing is not practical. The cooling tower analyzed in this study is void of fill, named shower cooling tower (SCT). However, the present study focuses mostly on experimental investigation of the SCT, and no systematic numerical method is available. In this paper, we first developed a one dimensional model and analyzed the heat and mass transfer processes of the SCT; then we used the concept of artificial neural network (ANN) to propose a computer design tool that can help the designer evaluate the outlet water temperature from a given set of experimentally obtained data. For comparison purposes and accurate evaluation of the predictions, part of the experimental data was used to train the neural network and the remainder to test the model. The results predicted by the ANN model were compared with those of the standard model and the experimental data. The ANN model predicted the outlet water temperature with a MAE (mean absolute error) of 1.31%, whereas the standard one dimensional model showed a MAE of 9.42%

  8. Coupling model and solving approach for performance evaluation of natural draft counter-flow wet cooling towers

    Directory of Open Access Journals (Sweden)

    Wang Wei

    2016-01-01

    Full Text Available When searching for the optimum condenser cooling water flow in a thermal power plant with natural draft cooling towers, it is essential to evaluate the outlet water temperature of cooling towers when the cooling water flow and inlet water temperature change. However, the air outlet temperature and tower draft or inlet air velocity are strongly coupled for natural draft cooling towers. Traditional methods, such as trial and error method, graphic method and iterative methods are not simple and efficient enough to be used for plant practice. In this paper, we combine Merkel equation with draft equation, and develop the coupled description for performance evaluation of natural draft cooling towers. This model contains two inputs: the cooling water flow, the inlet cooling water temperature and two outputs: the outlet water temperature, the inlet air velocity, equivalent to tower draft. In this model, we furthermore put forward a soft-sensing algorithm to calculate the total drag coefficient instead of empirical correlations. Finally, we design an iterative approach to solve this coupling model, and illustrate three cases to prove that the coupling model and solving approach proposed in our paper are effective for cooling tower performance evaluation.

  9. Experimental investigations on the contribution of the splash-zones in counter-flow cooling towers for water cooling

    International Nuclear Information System (INIS)

    Vladea, I.; Barbu, V.

    1976-01-01

    The relatively high cost of cooling tower packs has led to investigate the contribution of the splash-zones in counter-flow cooling towers, and thereby to determine whether the pack could not be reduced so far, as to be - under certain circumstance - completely eliminated. In this case, one would come to a pure splash cooling tower which would contain inside the equipment required for drop formation only. This problem was investigated experimentally, and it was found that the pack of such a cooling tower could not be eliminated without a reduction in tower effectiveness. (orig.) [de

  10. Extreme meteorological conditions

    International Nuclear Information System (INIS)

    Altinger de Schwarzkopf, M.L.

    1983-01-01

    Different meteorological variables which may reach significant extreme values, such as the windspeed and, in particular, its occurrence through tornadoes and hurricanes that necesarily incide and wich must be taken into account at the time of nuclear power plants' installation, are analyzed. For this kind of study, it is necessary to determine the basic phenomenum of design. Two criteria are applied to define the basic values of design for extreme meteorological variables. The first one determines the expected extreme value: it is obtained from analyzing the recurence of the phenomenum in a convened period of time, wich may be generally of 50 years. The second one determines the extreme value of low probability, taking into account the nuclear power plant's operating life -f.ex. 25 years- and considering, during said lapse, the occurrence probabilities of extreme meteorological phenomena. The values may be determined either by the deterministic method, which is based on the acknowledgement of the fundamental physical characteristics of the phenomena or by the probabilistic method, that aims to the analysis of historical statistical data. Brief comments are made on the subject in relation to the Argentine Republic area. (R.J.S.) [es

  11. A two staged condensation of vapors of an isobutane tower in installations for sulfuric acid alkylation

    Energy Technology Data Exchange (ETDEWEB)

    Smirnov, N.P.; Feyzkhanov, R.I.; Idrisov, A.D.; Navalikhin, P.G.; Sakharov, V.D.

    1983-01-01

    In order to increase the concentration of isobutane to greater than 72 to 76 percent in an installation for sulfuric acid alkylation, a system of two staged condensation of vapors from an isobutane tower is placed into operation. The first stage condenses the heavier part of the upper distillate of the tower, which is achieved through somewhat of an increase in the condensate temperature. The product which is condensed in the first stage is completely returned to the tower as a live irrigation. The vapors of the isobutane fraction which did not condense in the first stage are sent to two newly installed condensers, from which the product after condensation passes through intermediate tanks to further depropanization. The two staged condensation of vapors of the isobutane tower reduces the content of the inert diluents, the propane and n-butane in the upper distillate of the isobutane tower and creates more favorable conditions for the operation of the isobutane and propane tower.

  12. Updating of a finite element model of the Cruas 2 cooling tower

    International Nuclear Information System (INIS)

    Billet, L.

    1994-03-01

    A method based on modal analysis and inversion of a dynamic FEM model is used to detect changes in the dynamic behavior of nuclear plant cooling towers. Prior to detection, it is necessary to build a representative model of the structure. In this paper are given details about the CRUAS N. 2 cooling tower modelling and the updating procedure used to match the model to on-site measurements. First, were reviewed previous numerical and experimental studies on cooling towers vibrations. We found that the first eigenfrequencies of cooling towers are very sensitive to boundary conditions at the top and the bottom of the structure. Then, we built a beam and plate FEM model of the CRUAS N. 2 cooling tower. The first calculated modes were located in the proper frequency band (0.9 Hz - 1.30 Hz) but not distributed according to the experimental order. We decided to update the numerical model with MADMACS, an updating model software. It was necessary to: - decrease the shell stiffness by 30%; - increase the top ring stiffness by 300%; - modify the boundary conditions at the bottom by taking into account the soil impedance. In order to obtain a difference between the measured and the corresponding calculated frequencies less than 1%. The model was then judged to be realistic enough. (author). 23 figs., 13 refs., 1 annex

  13. On the optimum performance of forced draft counter flow cooling towers

    International Nuclear Information System (INIS)

    Soeylemez, M.S.

    2004-01-01

    A thermo-hydraulic performance optimization analysis is presented, yielding simple algebraic formula for estimating the optimum performance point of counter current mechanical draft wet cooling towers. The effectiveness-Ntu method is used in the present study, together with the derivation of psychometric properties of moist air based on a numerical approximation method, for thermal performance analysis of wet cooling towers of the counter flow type

  14. Continuous measurements of methane from a tower network over Siberia

    Energy Technology Data Exchange (ETDEWEB)

    Sasakawa, M.; Machida, T.; Saeki, T.; Koyama, Y.; Maksyutov, S. (Center for Global Environmental Research, National Inst. for Environmental Studies, Tsukuba, Ibaraki (Japan)); Shimoyama, K. (Inst. of Low Temperature Science, Hokkaido Univ., Hokkaido (Japan)); Tsuda, N. (Global Environmental Forum, Tokyo (Japan)); Suto, H. (Japan Aerospace Exploration Agency (Japan)); Arshinov, M.; Davydov, D.; Fofonov, A.; Krasnov, O. (Inst. of Atmospheric Optics, Russian Academy of Sciences, Siberian Branch (Russian Federation))

    2010-11-15

    We have been conducting continuous measurements of Methane (CH{sub 4}) concentration from an expanding network of towers (JR-STATION: Japan-Russia Siberian Tall Tower Inland Observation Network) located in taiga, steppe and wetland biomes of Siberia since 2004. High daytime means (>2000 ppb) observed simultaneously at several towers during winter, together with in situ weather data and NCEP/NCAR reanalysis data, indicate that high pressure systems caused CH{sub 4} accumulation at subcontinental scale due to the widespread formation of an inversion layer. Daytime means sometimes exceeded 2000 ppb, particularly in the summer of 2007 when temperature and precipitation rates were anomalously high over West Siberia, which implies that CH{sub 4} emission from wetlands were exceptionally high in 2007. Many hot spots detected by MODIS in the summer of 2007 illustrate that the contribution of biomass burning also cannot be neglected. Daytime mean CH{sub 4} concentrations from the Siberian tower sites were generally higher than CH{sub 4} values reported at NOAA coastal sites in the same latitudinal zone, and the difference in concentrations between two sets of sites was reproduced with a coupled Eulerian-Lagrangian transport model. Simulations of emissions from different CH{sub 4} sources suggested that the major contributor to variation switched from wetlands during summer to fossil fuel during winter.

  15. Exergy optimization of cooling tower for HGSHP and HVAC applications

    International Nuclear Information System (INIS)

    Singh, Kuljeet; Das, Ranjan

    2017-01-01

    Highlights: • Development of new correlations for outlet parameters with all inlet parameters. • Simultaneous achievement of required heat load and minimum exergy destruction. • Multiple combinations of parameters found for same heat load at minimized exergy. • Study useful for optimum control of cooling tower under varying ambient conditions. • Generalized optimization study can be implemented for any mechanical cooling tower. - Abstract: In the present work, a constrained inverse optimization method for building cooling applications is proposed to control the mechanical draft wet cooling tower by minimizing the exergy destruction and satisfying an imposed heat load under varying environmental conditions. The optimization problem is formulated considering the cooling dominated heating, ventilation and air conditioning (HVAC) and hybrid ground source heat pump (HGSHP). As per the requirement, new second degree correlations for the tower outlet parameters (water temperature, air dry and wet-bulb temperatures) with five inlet parameters (dry-bulb temperature, relative humidity, water inlet temperature, water and air mass flow rates) are developed. The Box–Behnken design response surface method is implemented for developing the correlations. Subsequently, the constrained optimization problem is solved using augmented Lagrangian genetic algorithm. This work further developed optimum inlet parameters operating curves for the HGSHP and the HVAC systems under varying environmental conditions aimed at minimizing the exergy destruction along with the fulfillment of the required heat load.

  16. Modern history of meteorological services with pictures for a century

    International Nuclear Information System (INIS)

    2004-07-01

    This book deals with modern history of meteorological services with pictures for a century. It is divided into twelve chapters, which mention meteorological services before the Joseon Dynasty period, meteorological observation about surface weather observation, aero logical observation, meteorological satellite, seismometry, observation on yellow dust, and observation on the falling of thunderbolt, weather forecast, meteorological telecommunication, education for weather, research for weather, promotion on weather, international cooperation, main events, special aid on meteorological services, meteorological disaster and the list of the offices for meteorological services.

  17. 76 FR 36983 - Marking Meteorological Evaluation Towers

    Science.gov (United States)

    2011-06-24

    ... other land cover but still remain visible to pilots. The Helicopter Association International... more power than red lights. While solar lights may be a possible option, the FAA has not studied solar...

  18. Cedar Hill Tower Data

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A meteorological data system was designed, assembled, and installed to obtain, on a continuous basis, wind and temperature information at 12 levels on a television...

  19. A systemic approach for optimal cooling tower operation

    International Nuclear Information System (INIS)

    Cortinovis, Giorgia F.; Paiva, Jose L.; Song, Tah W.; Pinto, Jose M.

    2009-01-01

    The thermal performance of a cooling tower and its cooling water system is critical for industrial plants, and small deviations from the design conditions may cause severe instability in the operation and economics of the process. External disturbances such as variation in the thermal demand of the process or oscillations in atmospheric conditions may be suppressed in multiple ways. Nevertheless, such alternatives are hardly ever implemented in the industrial operation due to the poor coordination between the utility and process sectors. The complexity of the operation increases because of the strong interaction among the process variables. In the present work, an integrated model for the minimization of the operating costs of a cooling water system is developed. The system is composed of a cooling tower as well as a network of heat exchangers. After the model is verified, several cases are studied with the objective of determining the optimal operation. It is observed that the most important operational resources to mitigate disturbances in the thermal demand of the process are, in this order: the increase in recycle water flow rate, the increase in air flow rate and finally the forced removal of a portion of the water flow rate that enters the cooling tower with the corresponding make-up flow rate.

  20. Optical study of solar tower power plants

    International Nuclear Information System (INIS)

    Eddhibi, F; Amara, M Ben; Balghouthi, M; Guizani, A

    2015-01-01

    The central receiver technology for electricity generation consists of concentrating solar radiation coming from the solar tracker field into a central receiver surface located on the top of the tower. The heliostat field is constituted of a big number of reflective mirrors; each heliostat tracks the sun individually and reflects the sunlight to a focal point. Therefore, the heliostat should be positioned with high precision in order to minimize optical losses. In the current work, a mathematical model for the analysis of the optical efficiency of solar tower field power plant is proposed. The impact of the different factors which influence the optical efficiency is analyzed. These parameters are mainly, the shading and blocking losses, the cosine effect, the atmospheric attenuation and the spillage losses. A new method for the calculation of blocking and shadowing efficiency is introduced and validated by open literature

  1. Crosswinds Effect on the Thermal Performance of Wet Cooling Towers Under Variable Operating Conditions

    Science.gov (United States)

    Chen, You Liang; Shi, Yong Feng; Hao, Jian Gang; Chang, Hao; Sun, Feng Zhong

    2018-01-01

    In order to quantitatively analyze the influence of the variable operating parameters on the cooling performance of natural draft wet cooling towers (NDWCTs), a hot model test system was set up with adjustable ambient temperature and humidity, circulating water flowrate and temperature. In order to apply the hot model test results to the real tower, the crosswind Froude number is defined. The results show that the crosswind has a negative effect on the thermal performance of the cooling tower, and there is a critical crosswind velocity corresponding to the lowest cooling efficiency. According to the crosswind Froude number similarity, when the ambient temperature decreases, or the circulating water flowrate and temperature increase, the cooling tower draft force will increase, and the critical crosswind velocity will increase correspondingly.

  2. Numerical simulation of flow field in cooling tower of passive residual heat removal system of HTGR

    International Nuclear Information System (INIS)

    Li Xiaowei; Zhang Li; Wu Xinxin; He Shuyan

    2011-01-01

    Environmental wind will influence the working conditions of natural convection cooling tower. The velocity and temperature fields in the natural convection cooling tower of the HTGR residual heat removal system at different environmental wind velocities were numerically simulated. The results show that, if there is no wind baffle, the flow in the cooling tower is blocked when environmental wind velocity is higher than 6 m/s, residual heat can hardly be removed, and when wind velocity is higher than 9 m/s, the air even flow downwards in the tower, so wind baffle is very necessary. With the wind baffle installed, the cooling tower works well at the wind speed even higher than 9 m/s. The optimum baffle size and positions are also analyzed. (authors)

  3. Meteorological interpretation of transient LOD changes

    Science.gov (United States)

    Masaki, Y.

    2008-04-01

    The Earth’s spin rate is mainly changed by zonal winds. For example, seasonal changes in global atmospheric circulation and episodic changes accompanied with El Nĩ os are clearly detected n in the Length-of-day (LOD). Sub-global to regional meteorological phenomena can also change the wind field, however, their effects on the LOD are uncertain because such LOD signals are expected to be subtle and transient. In our previous study (Masaki, 2006), we introduced atmospheric pressure gradients in the upper atmosphere in order to obtain a rough picture of the meteorological features that can change the LOD. In this presentation, we compare one-year LOD data with meteorological elements (winds, temperature, pressure, etc.) and make an attempt to link transient LOD changes with sub-global meteorological phenomena.

  4. Cooling tower drift studies at the Paducah, Kentucky Gaseous Diffusion Plant

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, F. G.; Hanna, S. R.; Parr, P. D.

    1978-12-01

    The transfer and fate of chromium from cooling tower drift to terrestrial ecosystems were quantified with concentrations in plant materials (fescue grass) decreasing with increasing distance from the cooling tower. Results indicate that elemental content in drift water (mineral residue) may not be equivalent to the content in the recirculating cooling water of the tower. This hypothesis is contrary to basic assumptions in calculating drift emissions. Results suggest that differences in retention in litter and foliage are related to chemical properties of the drift rather than physical lodging of the particle residue. To determine the potential for movement of drift-derived chromium to surface streams, soil-water samplers (wells) were placed along a distance gradient to Little Bayou Creek. Preliminary model estimates of drift deposition are compared to deposition measurements.

  5. EVALUATION OF METEOROLOGICAL ALERT CHAIN IN CASTILLA Y LEÓN (SPAIN): How can the meteorological risk managers help researchers?

    Science.gov (United States)

    López, Laura; Guerrero-Higueras, Ángel Manuel; Sánchez, José Luis; Matía, Pedro; Ortiz de Galisteo, José Pablo; Rodríguez, Vicente; Lorente, José Manuel; Merino, Andrés; Hermida, Lucía; García-Ortega, Eduardo; Fernández-Manso, Oscar

    2013-04-01

    Evaluating the meteorological alert chain, or, how information is transmitted from the meteorological forecasters to the final users, passing through risk managers, is a useful tool that benefits all the links of the chain, especially the meteorology researchers and forecasters. In fact, the risk managers can help significantly to improve meteorological forecasts in different ways. Firstly, by pointing out the most appropriate type of meteorological format, and its characteristics when representing the meteorological information, consequently improving the interpretation of the already-existing forecasts. Secondly, by pointing out the specific predictive needs in their workplaces related to the type of significant meteorological parameters, temporal or spatial range necessary, meteorological products "custom-made" for each type of risk manager, etc. In order to carry out an evaluation of the alert chain in Castilla y León, we opted for the creation of a Panel of Experts made up of personnel specialized in risk management (Responsible for Protection Civil, Responsible for Alert Services and Hydrological Planning of Hydrographical Confederations, Responsible for highway maintenance, and management of fires, fundamentally). In creating this panel, a total of twenty online questions were evaluated, and the majority of the questions were multiple choice or open-ended. Some of the results show how the risk managers think that it would be interesting, or very interesting, to carry out environmental educational campaigns about the meteorological risks in Castilla y León. Another result is the elevated importance that the risk managers provide to the observation data in real-time (real-time of wind, lightning, relative humidity, combined indices of risk of avalanches, snowslides, index of fires due to convective activity, etc.) Acknowledgements The authors would like to thank the Junta de Castilla y León for its financial support through the project LE220A11-2.

  6. Upper estimates of complexity of algorithms for multi-peg Tower of Hanoi problem

    Directory of Open Access Journals (Sweden)

    Sergey Novikov

    2007-06-01

    Full Text Available There are proved upper explicit estimates of complexity of lgorithms: for multi-peg Tower of Hanoi problem with the limited number of disks, for Reve's puzzle and for $5$-peg Tower of Hanoi problem with the free number of disks.

  7. Modal Analysis on Fluid-Structure Interaction of MW-Level Vertical Axis Wind Turbine Tower

    Directory of Open Access Journals (Sweden)

    Tan Jiqiu

    2014-05-01

    Full Text Available In order to avoid resonance problem of MW-level vertical axis wind turbine induced by wind, a flow field model of the MW-level vertical axis wind turbine is established by using the fluid flow control equations, calculate flow’s velocity and pressure of the MW-level vertical axis wind turbine and load onto tower’s before and after surface, study the Modal analysis of fluid-structure interaction of MW-level vertical axis wind turbine tower. The results show that fluid-structure interaction field of MW- level vertical axis wind turbine tower has little effect on the modal vibration mode, but has a great effect on its natural frequency and the maximum deformation, and the influence will decrease with increasing of modal order; MW-level vertical axis wind turbine tower needs to be raised the stiffness and strength, its structure also needs to be optimized; In the case of satisfy the intensity, the larger the ratio of the tower height and wind turbines diameter, the more soft the MW-level vertical axis wind turbine tower, the lower its frequency.

  8. Review on Water Distribution of Cooling Tower in Power Station

    Science.gov (United States)

    Huichao, Zhang; Lei, Fang; Hao, Guang; Ying, Niu

    2018-04-01

    As the energy sources situation is becoming more and more severe, the importance of energy conservation and emissions reduction gets clearer. Since the optimization of water distribution system of cooling tower in power station can save a great amount of energy, the research of water distribution system gets more attention nowadays. This paper summarizes the development process of counter-flow type natural draft wet cooling tower and the water distribution system, and introduces the related domestic and international research situation. Combining the current situation, we come to the conclusion about the advantages and disadvantages of the several major water distribution modes, and analyze the problems of the existing water distribution ways in engineering application, furthermore, we put forward the direction of water distribution mode development on the basis knowledge of water distribution of cooling tower. Due to the water system can hardly be optimized again when it’s built, choosing an appropriate water distribution mode according to actual condition seems to be more significant.

  9. Experimental study of the influence of atmospheric conditions on the performance of natural draft dry cooling towers

    International Nuclear Information System (INIS)

    Markoczy, G.; Staempfli, E.

    1977-08-01

    The heat dissipation of cooling towers is influenced by atmospheric conditions. In order to establish these influences EIR conducted measurements on a natural draft dry cooling tower. During two measuring campaigns with a duration of total 10 weeks the performance of the cooling tower, the ambient air temperatures, the wind velocities and directions as well as air temperature at the top of the tower and in front of the heat exchangers were continuously measured and registered. The results achieved enable the quantitative description of the influence of the ambient air temperature, wind and temperature inversion on the performance of natural draft dry cooling towers. (Auth.)

  10. Full scale experimental study of a small natural draft dry cooling tower for concentrating solar thermal power plant

    International Nuclear Information System (INIS)

    Li, Xiaoxiao; Duniam, Sam; Gurgenci, Hal; Guan, Zhiqiang; Veeraragavan, Anand

    2017-01-01

    Highlights: • A 20 m high natural draft dry cooling tower is designed and tested. • The cooling tower model is refined and validated with the experimental data. • The performance of the cooling tower utilized in a CST power plant is investigated. • Ambient temperature effect on Rankine cycle and Brayton cycle is discussed. - Abstract: Concentrating solar thermal power system can provide low carbon, renewable energy resources in countries or regions with strong solar irradiation. For this kind of power plant which is likely to be located in the arid area, natural draft dry cooling tower is a promising choice. To develop the experimental studies on small cooling tower, a 20 m high natural draft dry cooling tower with fully instrumented measurement system was established by the Queensland Geothermal Energy Centre of Excellence. The performance of this cooling tower was measured with the constant heat input of 600 kW and 840 kW and with ambient temperature ranging from 20 °C to 32 °C. The cooling tower numerical model was refined and validated with the experimental data. The model of 1 MW concentrating solar thermal supercritical CO_2 power cycle was developed and integrated with the cooling tower model. The influences of changing ambient temperature and the performance of the cooling tower on efficiency of the power system were simulated. The differences of the mechanism of the ambient temperature effect on Rankine cycle and supercritical CO_2 Brayton cycle were analysed and discussed.

  11. The Fleet Numerical Meteorology and Oceanography Center (FNMOC) - Naval

    Science.gov (United States)

    Meteorology Oceanography Ice You are here: Home › FNMOC FNMOC Logo FNMOC Navigation Meteorology Products Oceanography Products Tropical Applications Climatology and Archived Data Info The Fleet Numerical Meteorology and Oceanography Center (FNMOC) The Fleet Numerical Meteorology and Oceanography Center (FNMOC

  12. Determination of fan flow and water rate adjustment for off-design cooling tower tests

    International Nuclear Information System (INIS)

    Vance, J.M.

    1984-02-01

    The determination of the performance of a mechanical draft cooling tower requires that the air mass flow through the tower be known. Since this flow is not measured, it has been customary to use the manufacturer's design air flow and adjust it by the one-third power of the ratio of the design to test fan horsepower. The most nearly correct approximation of air flow through a tower can be obtained by incrementally moving through the tower from air inlet to outlet while calculating mass flows, energy balances, and pressure drops for each increment and then utilizing fan curves to determine volumetric and mass flows. This procedure would account for changes in air humidity and density through the tower, evaporation of water, effect of water rate on air pressure drop, and changes in fan characteristics. These type calculations may be within the capabilities of all in the near future, but for the interim, it is recommended that a more elementary approach be used which can be handled with a good calculator and without any proprietary data. This approach depends on certain assumptions which are acceptable if the tower test is conducted within CTI code requirements. The fan must be considered a constant suction volume blower for a given blade pitch. The total pressure at the fan, a function of volumetric flow and wet air density, must be assumed to be unaffected by other considerations, and the fan horsepower must be assumed to change only as volumetric flow and wet air density changes. Given these assumptions, along with design information normally provided with a tower, the determination of air flow through a tower in a test can be made from CTI test data. The air flow, and consequently the water rate adjustment and corrected water to air ratio, are derived and found to be direct functions of horsepower and density and an inverse function of wet air humidities

  13. Interim report on the meteorological database

    International Nuclear Information System (INIS)

    Stage, S.A.; Ramsdell, J.V.; Simonen, C.A.; Burk, K.W.

    1993-01-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project is estimating radiation doses that individuals may have received from operations at Hanford from 1944 to the present. An independent Technical Steering Panel (TSP) directs the project, which is being conducted by the Battelle, Pacific Northwest Laboratories in Richland, Washington. The goals of HEDR, as approved by the TSP, include dose estimates and determination of confidence ranges for these estimates. This letter report describes the current status of the meteorological database. The report defines the meteorological data available for use in climate model calculations, describes the data collection procedures and the preparation and control of the meteorological database. This report also provides an initial assessment of the data quality. The available meteorological data are adequate for atmospheric calculations. Initial checks of the data indicate the data entry accuracy meets the data quality objectives

  14. Whitney towers, Gropes and Casson-Gordon style invariants of links

    OpenAIRE

    Kim, Min Hoon

    2014-01-01

    In this paper, we prove a conjecture of Friedl and Powell that their Casson-Gordon type invariant of 2-component link with linking number one is actually an obstruction to being height 3.5 Whitney tower/grope concordant to the Hopf Link. The proof employs the notion of solvable cobordism of 3-manifolds with boundary, which was introduced by Cha. We also prove that the Blanchfield form and the Alexander polynomial of links in $S^3$ give obstructions to height 3 Whitney tower/grope concordance....

  15. Frost protection for atmospheric cooling tower

    International Nuclear Information System (INIS)

    Legrand, G.

    1987-01-01

    When the atmospheric temperature is near or lower than zero it is necessary to reduce the air flow entering in a cooling tower. A wire netting mounted on the air inlet is sprinkled with cold water. The level of the ice curtain and consequently the air flow is regulated by aspersion by hot water [fr

  16. Virtual Meteorological Center

    Directory of Open Access Journals (Sweden)

    Marius Brinzila

    2007-10-01

    Full Text Available A virtual meteorological center, computer based with Internet possibility transmission of the information is presented. Circumstance data is collected with logging field meteorological station. The station collects and automatically save data about the temperature in the air, relative humidity, pressure, wind speed and wind direction, rain gauge, solar radiation and air quality. Also can perform sensors test, analyze historical data and evaluate statistical information. The novelty of the system is that it can publish data over the Internet using LabVIEW Web Server capabilities and deliver a video signal to the School TV network. Also the system performs redundant measurement of temperature and humidity and was improved using new sensors and an original signal conditioning module.

  17. Meteorological Data Analysis Using MapReduce

    Directory of Open Access Journals (Sweden)

    Wei Fang

    2014-01-01

    Full Text Available In the atmospheric science, the scale of meteorological data is massive and growing rapidly. K-means is a fast and available cluster algorithm which has been used in many fields. However, for the large-scale meteorological data, the traditional K-means algorithm is not capable enough to satisfy the actual application needs efficiently. This paper proposes an improved MK-means algorithm (MK-means based on MapReduce according to characteristics of large meteorological datasets. The experimental results show that MK-means has more computing ability and scalability.

  18. Mathematical modeling of a continuous alcoholic fermentation process in a two-stage tower reactor cascade with flocculating yeast recycle.

    Science.gov (United States)

    de Oliveira, Samuel Conceição; de Castro, Heizir Ferreira; Visconti, Alexandre Eliseu Stourdze; Giudici, Reinaldo

    2015-03-01

    Experiments of continuous alcoholic fermentation of sugarcane juice with flocculating yeast recycle were conducted in a system of two 0.22-L tower bioreactors in series, operated at a range of dilution rates (D 1 = D 2 = 0.27-0.95 h(-1)), constant recycle ratio (α = F R /F = 4.0) and a sugar concentration in the feed stream (S 0) around 150 g/L. The data obtained in these experimental conditions were used to adjust the parameters of a mathematical model previously developed for the single-stage process. This model considers each of the tower bioreactors as a perfectly mixed continuous reactor and the kinetics of cell growth and product formation takes into account the limitation by substrate and the inhibition by ethanol and biomass, as well as the substrate consumption for cellular maintenance. The model predictions agreed satisfactorily with the measurements taken in both stages of the cascade. The major differences with respect to the kinetic parameters previously estimated for a single-stage system were observed for the maximum specific growth rate, for the inhibition constants of cell growth and for the specific rate of substrate consumption for cell maintenance. Mathematical models were validated and used to simulate alternative operating conditions as well as to analyze the performance of the two-stage process against that of the single-stage process.

  19. The influence of airflow inlet region modifications on the local efficiency of natural draft cooling tower operation

    OpenAIRE

    Hočevar, Marko; Širok, Brane; Dvoršek, Matjaž; Holeček, Nikola; Donevski, Božin

    2015-01-01

    We present the influence of the cooling tower airflow inlet region modifications at the Šoštanj 4 thermal power plant on cooling tower local efficiency. Local efficiency change was estimated based on temperature fields of drift eliminators before and after the reconstruction of the cooling tower. Temperature fields were measured with thermal vision method. The local reduction of cooling tower efficiency was analyzed based on phenomenological relations of heat transfer obtained from the select...

  20. A theoretical model of rain–wind–induced in-plane galloping on overhead transmission tower-lines system

    Directory of Open Access Journals (Sweden)

    Chao Zhou

    2015-09-01

    Full Text Available Rain–wind–induced galloping phenomenon often occurs on overhead transmission tower-lines system, just as icing galloping and vortex-excited vibration; this kind of instability oscillation can cause power-line breakage or tower failure. However, the existing theoretical models of rain–wind–induced galloping are mainly based on the hypothesis of the overhead power-lines with fixed ends, which is inconsistent with the actual operation situation. Therefore, this article thus presents a preliminary theoretical study and proposes a new theoretical model taking into account the effect of tower excitations on the in-plane galloping of the overhead power-line and on the motion of the upper rain-line. The theoretical model is solved by Galerkin method and verified by the comparison with the test data obtained in the available literature involved with the overhead power-lines with fixed towers or moving towers. It turns out that the tower excitations may intensify the in-plane galloping amplitude of the overhead power-line within a certain range of frequency ratio and enable better comprehension of rain–wind–induced galloping mechanism.