WorldWideScience

Sample records for single line source

  1. Gadolinium-153 line sources

    Energy Technology Data Exchange (ETDEWEB)

    Lebedev, V.M. E-mail: kar@orip.niiar.simbirsk.su; Gordeev, J.N.; Karelin, E.A.; Gavrilov, V.D

    2000-11-15

    The technology for Gd-153 line source production has been developed at SSC RIAR. The source active core is made of Al-Gd{sub 2}O{sub 3} composition by means of one of the following ways: either collecting pressed pellets or filling the source body with the composition followed by sintering. The composition is prepared by gadolinium salt thermal destruction on aluminium particles. The method allows setting gadolinium mass fraction (from 0.02 to 6%) with high accuracy and uniformity of distribution in the composition volume of more than 95%.

  2. Alternate Double Single Track Lines

    Energy Technology Data Exchange (ETDEWEB)

    Moraga Contreras, P.; Grande Andrade, Z.; Castillo Ron, E.

    2016-07-01

    The paper discusses the advantages and shortcomings of alternate double single track (ADST) lines with respect to double track lines for high speed lines. ADST lines consists of sequences of double and single track segments optimally selected in order to reduce the construction and maintenance costs of railway lines and to optimize the timetables used to satisfy a given demand. The single tracks are selected to coincide with expensive segments (tunnels and viaducts) and the double tracks are chosen to coincide with flat areas and only where they are necessary. At the same time, departure times are adjusted for trains to cross at the cheap double track segments. This alternative can be used for new lines and also for existing conventional lines where some new tracks are to be constructed to reduce travel time (increase speed). The ADST proposal is illustrated with some examples of both types (new lines and where conventional lines exist), including the Palencia-Santander, the Santiago-Valparaíso-Viña del Mar and the Dublin-Belfast lines, where very important reductions (90 %) are obtained, especially where a railway infrastructure already exist. (Author)

  3. Single particle mass spectral signatures from vehicle exhaust particles and the source apportionment of on-line PM2.5by single particle aerosol mass spectrometry.

    Science.gov (United States)

    Yang, Jian; Ma, Shexia; Gao, Bo; Li, Xiaoying; Zhang, Yanjun; Cai, Jing; Li, Mei; Yao, Ling'ai; Huang, Bo; Zheng, Mei

    2017-09-01

    In order to accurately apportion the many distinct types of individual particles observed, it is necessary to characterize fingerprints of individual particles emitted directly from known sources. In this study, single particle mass spectral signatures from vehicle exhaust particles in a tunnel were performed. These data were used to evaluate particle signatures in a real-world PM 2.5 apportionment study. The dominant chemical type originating from average positive and negative mass spectra for vehicle exhaust particles are EC species. Four distinct particle types describe the majority of particles emitted by vehicle exhaust particles in this tunnel. Each particle class is labeled according to the most significant chemical features in both average positive and negative mass spectral signatures, including ECOC, NaK, Metal and PAHs species. A single particle aerosol mass spectrometry (SPAMS) was also employed during the winter of 2013 in Guangzhou to determine both the size and chemical composition of individual atmospheric particles, with vacuum aerodynamic diameter (d va ) in the size range of 0.2-2μm. A total of 487,570 particles were chemically analyzed with positive and negative ion mass spectra and a large set of single particle mass spectra was collected and analyzed in order to identify the speciation. According to the typical tracer ions from different source types and classification by the ART-2a algorithm which uses source fingerprints for apportioning ambient particles, the major sources of single particles were simulated. Coal combustion, vehicle exhaust, and secondary ion were the most abundant particle sources, contributing 28.5%, 17.8%, and 18.2%, respectively. The fraction with vehicle exhaust species particles decreased slightly with particle size in the condensation mode particles. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. GPC Single Source Letter

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  5. A Rolling Line Source for a Seismic Sonar

    Science.gov (United States)

    2002-06-01

    shakers used were a new version, capable of 75 watts continuous power, because they had the addition of heat sink fins (Fig. 4). The shaker...single shaker, removed from its casing, and heat sink, and buried. Source four was the rolling line source shaker. And source five was the paddle...Meeting on Submarine Acoustics, Institute of Marine Studies of the Brazilian Navy, Ilha do Governador, Rio de Janerio, Brazil, Sep. 1997. 9. Smith

  6. A directly heated electron beam line source

    International Nuclear Information System (INIS)

    Iqbal, M.; Masood, K.; Rafiq, M.; Chaudhry, M.A.

    2002-05-01

    A 140-mm cathode length, Electron Beam Line Source with a high degree of focusing of the beam is constructed. The design principles and basic characteristic considerations for electron beam line source consists of parallel plate electrode geometric array as well as a beam power of 35kW are worked out. The dimensions of the beam at the work site are 1.25xl00mm. The gun is designed basically for the study of evaporation and deposition characteristic of refractory metals for laboratory use. However, it may be equally used for melting and casting of these metals. (author)

  7. Sub-megahertz linewidth single photon source

    Directory of Open Access Journals (Sweden)

    Markus Rambach

    2016-12-01

    Full Text Available We report 100% duty cycle generation of sub-MHz single photon pairs at the rubidium D1 line using cavity-enhanced spontaneous parametric downconversion. The temporal intensity cross correlation function exhibits a bandwidth of 666±16 kHz for the single photons, an order of magnitude below the natural linewidth of the target transition. A half-wave plate inside our cavity helps to achieve triple resonance between pump, signal, and idler photon, reducing the bandwidth and simplifying the locking scheme. Additionally, stabilisation of the cavity to the pump frequency enables the 100% duty cycle. The quantum nature of the source is confirmed by the idler-triggered second-order autocorrelation function at τ=0 to be gs,s(2(0= 0.016±0.002 for a heralding rate of 5 kHz. The generated photons are well-suited for storage in quantum memory schemes with sub-natural linewidths, such as gradient echo memories.

  8. Low Complexity Bayesian Single Channel Source Separation

    DEFF Research Database (Denmark)

    Beierholm, Thomas; Pedersen, Brian Dam; Winther, Ole

    2004-01-01

    We propose a simple Bayesian model for performing single channel speech separation using factorized source priors in a sliding window linearly transformed domain. Using a one dimensional mixture of Gaussians to model each band source leads to fast tractable inference for the source signals. Simul...

  9. Assessing Model Characterization of Single Source ...

    Science.gov (United States)

    Aircraft measurements made downwind from specific coal fired power plants during the 2013 Southeast Nexus field campaign provide a unique opportunity to evaluate single source photochemical model predictions of both O3 and secondary PM2.5 species. The model did well at predicting downwind plume placement. The model shows similar patterns of an increasing fraction of PM2.5 sulfate ion to the sum of SO2 and PM2.5 sulfate ion by distance from the source compared with ambient based estimates. The model was less consistent in capturing downwind ambient based trends in conversion of NOX to NOY from these sources. Source sensitivity approaches capture near-source O3 titration by fresh NO emissions, in particular subgrid plume treatment. However, capturing this near-source chemical feature did not translate into better downwind peak estimates of single source O3 impacts. The model estimated O3 production from these sources but often was lower than ambient based source production. The downwind transect ambient measurements, in particular secondary PM2.5 and O3, have some level of contribution from other sources which makes direct comparison with model source contribution challenging. Model source attribution results suggest contribution to secondary pollutants from multiple sources even where primary pollutants indicate the presence of a single source. The National Exposure Research Laboratory (NERL) Computational Exposure Division (CED) develops and evaluates data, deci

  10. Sourcing human embryos for embryonic stem cell lines: Problems & perspectives

    Directory of Open Access Journals (Sweden)

    Rajvi H Mehta

    2014-01-01

    Full Text Available The ability to successfully derive human embryonic stem cells (hESC lines from human embryos following in vitro fertilization (IVF opened up a plethora of potential applications of this technique. These cell lines could have been successfully used to increase our understanding of human developmental biology, transplantation medicine and the emerging science of regenerative medicine. The main source for human embryos has been ′discarded′ or ′spare′ fresh or frozen human embryos following IVF. It is a common practice to stimulate the ovaries of women undergoing any of the assisted reproductive technologies (ART and retrieve multiple oocytes which subsequently lead to multiple embryos. Of these, only two or maximum of three embryos are transferred while the rest are cryopreserved as per the decision of the couple. In case a couple does not desire to ′cryopreserve′ their embryos then all the embryos remaining following embryo transfer can be considered ′spare′ or if a couple is no longer in need of the ′cryopreserved′ embryos then these also can be considered as ′spare′. But, the question raised by the ethicists is, "what about ′slightly′ over-stimulating a woman to get a few extra eggs and embryos? The decision becomes more difficult when it comes to ′discarded′ embryos. As of today, the quality of the embryos is primarily assessed based on morphology and the rate of development mainly judged by single point assessment. Despite many criteria described in the literature, the quality assessment is purely subjective. The question that arises is on the decision of ′discarding′ embryos. What would be the criteria for discarding embryos and the potential ′use′ of ESC derived from the ′abnormal appearing′ embryos? This paper discusses some of the newer methods to procure embryos for the derivation of embryonic stem cell lines which will respect the ethical concerns but still provide the source material.

  11. Sourcing human embryos for embryonic stem cell lines: problems & perspectives.

    Science.gov (United States)

    Mehta, Rajvi H

    2014-11-01

    The ability to successfully derive human embryonic stem cells (hESC) lines from human embryos following in vitro fertilization (IVF) opened up a plethora of potential applications of this technique. These cell lines could have been successfully used to increase our understanding of human developmental biology, transplantation medicine and the emerging science of regenerative medicine. The main source for human embryos has been 'discarded' or 'spare' fresh or frozen human embryos following IVF. It is a common practice to stimulate the ovaries of women undergoing any of the assisted reproductive technologies (ART) and retrieve multiple oocytes which subsequently lead to multiple embryos. Of these, only two or maximum of three embryos are transferred while the rest are cryopreserved as per the decision of the couple. in case a couple does not desire to 'cryopreserve' their embryos then all the embryos remaining following embryo transfer can be considered 'spare' or if a couple is no longer in need of the 'cryopreserved' embryos then these also can be considered as 'spare'. But, the question raised by the ethicists is, "what about 'slightly' over-stimulating a woman to get a few extra eggs and embryos? The decision becomes more difficult when it comes to 'discarded' embryos. As of today, the quality of the embryos is primarily assessed based on morphology and the rate of development mainly judged by single point assessment. Despite many criteria described in the literature, the quality assessment is purely subjective. The question that arises is on the decision of 'discarding' embryos. What would be the criteria for discarding embryos and the potential 'use' of ESC derived from the 'abnormal appearing' embryos? This paper discusses some of the newer methods to procure embryos for the derivation of embryonic stem cell lines which will respect the ethical concerns but still provide the source material.

  12. SOFIA: a flexible source finder for 3D spectral line data

    NARCIS (Netherlands)

    Serra, Paolo; Westmeier, Tobias; Giese, Nadine; Jurek, Russell; Flöer, Lars; Popping, Attila; Winkel, Benjamin; van der Hulst, Thijs; Meyer, Martin; Koribalski, Bärbel S.; Staveley-Smith, Lister; Courtois, Hélène

    We introduce SOFIA, a flexible software application for the detection and parametrization of sources in 3D spectral line data sets. SOFIA combines for the first time in a single piece of software a set of new source-finding and parametrization algorithms developed on the way to future H I surveys

  13. Turbulent dispersion from line sources in grid turbulence

    Science.gov (United States)

    Viswanathan, Sharadha; Pope, Stephen B.

    2008-10-01

    Probability density function (PDF) calculations are reported for the dispersion from line sources in decaying grid turbulence. The calculations are performed using a modified form of the interaction by exchange with the conditional mean (IECM) mixing model. These flows pose a significant challenge to statistical models because the scalar length scale (of the initial plume) is much smaller than the turbulence integral scale. Consequently, this necessitates incorporating the effects of molecular diffusion in order to model laboratory experiments. Previously, Sawford [Flow Turb. Combust. 72, 133 (2004)] performed PDF calculations in conjunction with the IECM mixing model, modeling the effects of molecular diffusion as a random walk in physical space and using a mixing time scale empirically fit to the experimental data of Warhaft [J. Fluid Mech. 144, 363 (1984)]. The resulting transport equation for the scalar variance contains a spurious production term. In the present work, the effects of molecular diffusion are instead modeled by adding a conditional mean scalar drift term, thus avoiding the spurious production of scalar variance. A laminar wake model is used to obtain an analytic expression for the mixing time scale at small times, and this is used as part of a general specification of the mixing time scale. Based on this modeling, PDF calculations are performed, and comparison is made primarily with the experimental data of Warhaft on single and multiple line sources and with the previous calculations of Sawford. A heated mandoline is also considered with comparison to the experimental data of Warhaft and Lumley [J. Fluid Mech. 88, 659 (1978)]. This establishes the validity of the proposed model and the significant effect of molecular diffusion on the decay of scalar fluctuations. The following are the significant predictions of the model. For the line source, the effect of the source size is limited to early times and can be completely accounted for by simple

  14. An electromagnetically focused electron beam line source

    International Nuclear Information System (INIS)

    Iqbal, Munawar; Masood, Khalid; Rafiq, Mohammad; Chaudhary, Maqbool A.; Aleem, Fazal-e-

    2003-01-01

    A directly heated thermionic electron beam source was constructed. A tungsten wire of length 140 mm with diameter 0.9 mm was used as a cathode. An emission current of 5000 mA was achieved at an input heating power of 600 W. Cathode to anode distance of 6 mm with acceleration voltage of 10 kV was used. A uniform external magnetic field of 50 G was employed to obtain a well-focused electron beam at a deflection of 180 deg., with cathode to work site distance of 130 mm. Dimensions of the beam (1.25x120 mm) recorded at the work site were found to be in good agreement with the designed length of cathode. The deformation of the cathode was overcome by introducing a spring action mechanism, which gives uniform emission current density throughout the emission surface. We have achieved the saturation limit of the designed source resulting in smooth and swift operation of the gun for many hours (10-15 h continuously). The design of gun is so simple that it can accommodate longer cathodes for obtaining higher emission values. This gun has made it possible to coat large substrate surfaces at much faster evaporation rate at lower cost. It can also be useful in large-scale vacuum metallurgy plants for melting, welding and heat treatment

  15. Equitable Prices of Single-Source Drugs in Thailand.

    Science.gov (United States)

    Ngorsuraches, Surachat; Chaiyakan, Kanokkan

    2015-08-01

    In Thailand, total drug expenditure has grown rapidly. Recently, the Thai government has addressed the issue of drug pricing, but the prices of single-source drugs remain a major challenge. To examine equitable prices of single-source drugs in Thailand. A total of 98 single-source and high-expenditure drugs were examined. Unit prices from the Drug and Medical Supplies Information Center (DMSIC) and National Average Drug Acquisition Cost (NADAC) were used to represent drug prices at the provider level in Thailand and the U.S., respectively. Data for measuring drug affordability, e.g., dose and poverty line, were obtained from Micromedex online and the National Statistical Office (NSO). The U.S. drug prices were adjusted by the Human Development Index (HDI) to be equitable prices for Thailand. Purchasing Power Parity (PPP) was used to convert US currency into Thai baht. All prices in this study were based on the year 2012. Catastrophic, Impoverishment, and WHO/Health Action International (HAI) approaches were used to determine Thai citizens' ability to afford the study drugs. Finally, uncertainty analyses were conducted. From all study drugs, 55 single-source drugs were priced higher than their equitable prices, ranging from 0.38 to 422.36% higher. Among these, 28 items were antineoplastic drugs. The prices of drugs outside the National List of Essential Medicines (NLEM), as well as the country's newer drugs, tended to be higher than their calculated equitable prices. The majority of drugs in Thailand priced higher than equitable prices were unaffordable for most Thai citizens. The uncertainty analyses revealed that almost all results were relatively robust. Most single-source drug prices in Thailand were higher than their equitable prices, and were likely to be unaffordable to Thai citizens.

  16. FMEF Electrical single line diagram and panel schedule verification process

    International Nuclear Information System (INIS)

    Fong, S.K.

    1998-01-01

    Since the FMEF did not have a mission, a formal drawing verification program was not developed, however, a verification process on essential electrical single line drawings and panel schedules was established to benefit the operations lock and tag program and to enhance the electrical safety culture of the facility. The purpose of this document is to provide a basis by which future landlords and cognizant personnel can understand the degree of verification performed on the electrical single lines and panel schedules. It is the intent that this document be revised or replaced by a more formal requirements document if a mission is identified for the FMEF

  17. Distributed quantum computing with single photon sources

    International Nuclear Information System (INIS)

    Beige, A.; Kwek, L.C.

    2005-01-01

    Full text: Distributed quantum computing requires the ability to perform nonlocal gate operations between the distant nodes (stationary qubits) of a large network. To achieve this, it has been proposed to interconvert stationary qubits with flying qubits. In contrast to this, we show that distributed quantum computing only requires the ability to encode stationary qubits into flying qubits but not the conversion of flying qubits into stationary qubits. We describe a scheme for the realization of an eventually deterministic controlled phase gate by performing measurements on pairs of flying qubits. Our scheme could be implemented with a linear optics quantum computing setup including sources for the generation of single photons on demand, linear optics elements and photon detectors. In the presence of photon loss and finite detector efficiencies, the scheme could be used to build large cluster states for one way quantum computing with a high fidelity. (author)

  18. Current Source Density Estimation for Single Neurons

    Directory of Open Access Journals (Sweden)

    Dorottya Cserpán

    2014-03-01

    Full Text Available Recent developments of multielectrode technology made it possible to measure the extracellular potential generated in the neural tissue with spatial precision on the order of tens of micrometers and on submillisecond time scale. Combining such measurements with imaging of single neurons within the studied tissue opens up new experimental possibilities for estimating distribution of current sources along a dendritic tree. In this work we show that if we are able to relate part of the recording of extracellular potential to a specific cell of known morphology we can estimate the spatiotemporal distribution of transmembrane currents along it. We present here an extension of the kernel CSD method (Potworowski et al., 2012 applicable in such case. We test it on several model neurons of progressively complicated morphologies from ball-and-stick to realistic, up to analysis of simulated neuron activity embedded in a substantial working network (Traub et al, 2005. We discuss the caveats and possibilities of this new approach.

  19. Single channel in-line multimodal digital holography.

    Science.gov (United States)

    Rivenson, Yair; Katz, Barak; Kelner, Roy; Rosen, Joseph

    2013-11-15

    We present a new single channel in-line setup for holographic recording that can properly record various objects that cannot be recorded by the Gabor holographic method. This configuration allows the recording of holograms based on several modalities while addressing important issues of the original Gabor setup, including the well-known twin-image problem and the weak scattering condition.

  20. Reduction of the environmental concentration of air pollutants by proper geometrical orientation of industrial line sources

    International Nuclear Information System (INIS)

    Tadmor, J.

    1980-01-01

    An account is given of an Israeli study of two line sources, one composed of 10 and the other of 20 individual sources. The height of release ranged from 15.7 to 39.6 m, with a uniform rate of release of a gaseous pollutant of 1 Ci/s for each source. Average pollutant concentration was plotted as a function of the rotation angle of the line sources. Reduction of pollutant concentration by a particular rotation of the line sources attained values of up to 50%. At certain rotation angles of the line sources, the environmental concentration was lower even as compared with a single high source. Results also depended on atmospheric conditions. It is suggested that considering the increase in cost of augmenting the height of release as a means of reducing the air pollutant concentration, determination of the optimum geometric orientation of the line sources should be considered as an economical means of improving environmental air quality. (U.K.)

  1. Apportionment of urban aerosol sources in Chongqing (China) using synergistic on-line techniques

    Science.gov (United States)

    Chen, Yang; Yang, Fumo

    2016-04-01

    The sources of ambient fine particulate matter (PM2.5) during wintertime at a background urban location in Chongqing (southwestern China) have been determined. Aerosol chemical composition analyses were performed using multiple on-line techniques, such as single particle aerosol mass spectrometer (SPAMS) for single particle chemical composition, on-line elemental carbon-organic carbon analyzer (on-line OC-EC), on-line X-ray fluorescence (XRF) for elements, and in-situ Gas and Aerosol Compositions monitor (IGAC) for water-soluble ions in PM2.5. All the datasets from these techniques have been adjusted to a 1-h time resolution for receptor model input. Positive matrix factorization (PMF) has been used for resolving aerosol sources. At least six sources, including domestic coal burning, biomass burning, dust, traffic, industrial and secondary/aged factors have been resolved and interpreted. The synergistic on-line techniques were helpful for identifying aerosol sources more clearly than when only employing the results from the individual techniques. This results are useful for better understanding of aerosol sources and atmospheric processes.

  2. On the finite line source problem in diffusion theory

    International Nuclear Information System (INIS)

    Mikkelsen, T.; Troen, I.; Larsen, S.E.

    1981-09-01

    A simple formula for calculating dispersion from a continuous finite line source, placed at right angles to the mean wind direction, is derived on the basis of statistical theory. Comparison is made with the virtual source concept usually used and this is shown to be correct only in the limit where the virtual time lag Tsub(v) is small compared to the timescale of the turbulence tsub(l). (Auth.)

  3. Single exosome study reveals subpopulations distributed among cell lines with variability related to membrane content

    Directory of Open Access Journals (Sweden)

    Zachary J. Smith

    2015-12-01

    Full Text Available Current analysis of exosomes focuses primarily on bulk analysis, where exosome-to-exosome variability cannot be assessed. In this study, we used Raman spectroscopy to study the chemical composition of single exosomes. We measured spectra of individual exosomes from 8 cell lines. Cell-line-averaged spectra varied considerably, reflecting the variation in total exosomal protein, lipid, genetic, and cytosolic content. Unexpectedly, single exosomes isolated from the same cell type also exhibited high spectral variability. Subsequent spectral analysis revealed clustering of single exosomes into 4 distinct groups that were not cell-line specific. Each group contained exosomes from multiple cell lines, and most cell lines had exosomes in multiple groups. The differences between these groups are related to chemical differences primarily due to differing membrane composition. Through a principal components analysis, we identified that the major sources of spectral variation among the exosomes were in cholesterol content, relative expression of phospholipids to cholesterol, and surface protein expression. For example, exosomes derived from cancerous versus non-cancerous cell lines can be largely separated based on their relative expression of cholesterol and phospholipids. We are the first to indicate that exosome subpopulations are shared among cell types, suggesting distributed exosome functionality. The origins of these differences are likely related to the specific role of extracellular vesicle subpopulations in both normal cell function and carcinogenesis, and they may provide diagnostic potential at the single exosome level.

  4. On-line sources of toxicological information in Canada

    International Nuclear Information System (INIS)

    Racz, William J.; Ecobichon, Donald J.; Baril, Marc

    2003-01-01

    This paper will provide an overview of the on-line resources available in toxicology in Canada. It will describe a brief history of The Society of Toxicology of Canada, with reference to other societies and also provide information on education, research and other resources related to toxicology. Toxicology in Canada emerged as a distinct and vibrant discipline following the thalidomide tragedy of the 1960s. In the pharmaceutical industry and government, toxicology was readily established as an essential component of drug development and safety, and as the need for toxicologists expanded, training programs were established, usually in collaboration with departments of pharmacology. In the last two to three decades other disciplines, environmental biology, analytical chemistry and epidemiology joined the ranks of toxicology. The on-line sources of toxicology information are rapidly expanding. This article describes those sources considered by the authors to be important from a national and international perspective. The majority of these sources are professional organizations and government agencies

  5. Source Lines Counter (SLiC) Version 4.0

    Science.gov (United States)

    Monson, Erik W.; Smith, Kevin A.; Newport, Brian J.; Gostelow, Roli D.; Hihn, Jairus M.; Kandt, Ronald K.

    2011-01-01

    Source Lines Counter (SLiC) is a software utility designed to measure software source code size using logical source statements and other common measures for 22 of the programming languages commonly used at NASA and the aerospace industry. Such metrics can be used in a wide variety of applications, from parametric cost estimation to software defect analysis. SLiC has a variety of unique features such as automatic code search, automatic file detection, hierarchical directory totals, and spreadsheet-compatible output. SLiC was written for extensibility; new programming language support can be added with minimal effort in a short amount of time. SLiC runs on a variety of platforms including UNIX, Windows, and Mac OSX. Its straightforward command-line interface allows for customization and incorporation into the software build process for tracking development metrics. T

  6. A compact source for bunches of singly charged atomic ions

    Science.gov (United States)

    Murböck, T.; Schmidt, S.; Andelkovic, Z.; Birkl, G.; Nörtershäuser, W.; Vogel, M.

    2016-04-01

    We have built, operated, and characterized a compact ion source for low-energy bunches of singly charged atomic ions in a vacuum beam line. It is based on atomic evaporation from an electrically heated oven and ionization by electron impact from a heated filament inside a grid-based ionization volume. An adjacent electrode arrangement is used for ion extraction and focusing by applying positive high-voltage pulses to the grid. The method is particularly suited for experimental environments which require low electromagnetic noise. It has proven simple yet reliable and has been used to produce μs-bunches of up to 106 Mg+ ions at a repetition rate of 1 Hz. We present the concept, setup and characterizing measurements. The instrument has been operated in the framework of the SpecTrap experiment at the HITRAP facility at GSI/FAIR to provide Mg+ ions for sympathetic cooling of highly charged ions by laser-cooled 24Mg+.

  7. Performance of single mechanoluminescent particle as ubiquitous light source.

    Science.gov (United States)

    Terasaki, Nao; Xu, Chao-Nan

    2014-08-01

    In this study, we have investigated mechanoluminescent (ML) performance of single ML particle as ubiquitous light source. When using high-speed CCD camera with image intensifier and microscopic equipment, mechanoluminescence from single particle was observed. As to the quantitative ML evaluation of the single ML particle was carried out using photomultiplier, and successfully estimated the performance of the single ML particle as an intensity controllable light source in nW order. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Walking Posture Control of Transmission Line Single Arm Inspection Robot

    Science.gov (United States)

    Yan, Yu; Liu, Xiaqing; Li, Jinliang; Ou, Yuexiong

    2017-07-01

    To control the walking posture according to transmission line single arm inspection robot, the robot is divided into normal walking and climbing walking two state, and gives the definition, then based on the state space method of state variable feedback and PD control method is used to control the two states, two kinds of control method of simulation by using Matlab, in the end, the two control methods proposed is validated in the actual circuit structures. The results show that, the proposed control method is rapid and effective, and can meet the needs of practical application.

  9. Numerical design of in-line X-ray phase-contrast imaging based on ellipsoidal single-bounce monocapillary

    International Nuclear Information System (INIS)

    Sun, Weiyuan; Liu, Zhiguo; Sun, Tianxi; Peng, Song; Ma, Yongzhong; Ding, Xunliang

    2014-01-01

    A new device using an ellipsoidal single-bounce monocapillary X-ray optics was numerically designed to realize in-line X-ray phase-contrast imaging by using conventional laboratory X-ray source with a large spot. Numerical simulation results validated the effectiveness of the proposed device and approach. The ellipsoidal single-bounce monocapillary X-ray optics had potential applications in the in-line phase contrast imaging with polychromatic X-rays

  10. Single-photon source engineering using a Modal Method

    DEFF Research Database (Denmark)

    Gregersen, Niels

    Solid-state sources of single indistinguishable photons are of great interest for quantum information applications. The semiconductor quantum dot embedded in a host material represents an attractive platform to realize such a single-photon source (SPS). A near-unity efficiency, defined as the num...... nanowire SPSs...

  11. E-line: A new crystal collimator beam line for source size measurements at CHESS

    International Nuclear Information System (INIS)

    White, Jeffrey A.; Revesz, Peter; Finkelstein, Ken

    2007-01-01

    A new X-ray beam line has been constructed at cornell high energy synchrotron source (CHESS) to measure the vertical and horizontal source size of the positron particle beam. The cornell laboratory of elementary particle physics (LEPP) operates the storage ring (CESR) for X-ray generation for the CHESS user community by circulating electrons and their antimatter counterpart positrons in counter-rotating beams. As the laboratory reduces the emittances of particle beams to increase X-ray brilliance, there has been an increasing need for diagnostic tools to measure and monitor source size. A beam line front end that accesses the positron synchrotron light has been fitted with an experimental chamber and apparatus of compact design capable of horizontal and vertical source size measurement using the 'crystal collimator' technique, and an additional setup for vertical beam position monitoring using a luminescence-based X-ray video beam position monitoring system. The crystal collimators each consist of two Si(2 2 0) crystals in a dispersive (+,+) arrangement that diffract X-rays to a fluorescent material coated on a view port observed with a CCD camera. Measurements of the positron vertical beam size using the crystal collimation method at E-line are compared with measurements of visible synchrotron light at a remotely located dedicated port on the storage ring

  12. Equivalent properties of single event burnout induced by different sources

    International Nuclear Information System (INIS)

    Yang Shiyu; Cao Zhou; Da Daoan; Xue Yuxiong

    2009-01-01

    The experimental results of single event burnout induced by heavy ions and 252 Cf fission fragments in power MOSFET devices have been investigated. It is concluded that the characteristics of single event burnout induced by 252 Cf fission fragments is consistent to that in heavy ions. The power MOSFET in the 'turn-off' state is more susceptible to single event burnout than it is in the 'turn-on' state. The thresholds of the drain-source voltage for single event burnout induced by 173 MeV bromine ions and 252 Cf fission fragments are close to each other, and the burnout cross section is sensitive to variation of the drain-source voltage above the threshold of single event burnout. In addition, the current waveforms of single event burnouts induced by different sources are similar. Different power MOSFET devices may have different probabilities for the occurrence of single event burnout. (authors)

  13. Summit Petroleum Corporation Single Source Determination

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  14. Single Source Determination for General Dynamics

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  15. Time-dependent sources identification for transmission lines problems

    Directory of Open Access Journals (Sweden)

    J. Benoit

    2015-10-01

    Full Text Available This paper is devoted to introduce an extension to the Linear Combination of Configuration Fields (LCCF. This new numerical method was designed to compute the time profile of an electromagnetic source radiating a specified electromagnetic field in all or part of the computational domain, for a specified duration. Here, we extend this idea within the framework of a transmission lines network. The principle of the method is first validated numerically. Then we prospect the same ideas in a real-data experiment which shows that the method is ready for real-life investigations.

  16. Analytic Approximation to Radiation Fields from Line Source Geometry

    International Nuclear Information System (INIS)

    Michieli, I.

    2000-01-01

    Line sources with slab shields represent typical source-shield configuration in gamma-ray attenuation problems. Such shielding problems often lead to the generalized Secant integrals of the specific form. Besides numerical integration approach, various expansions and rational approximations with limited applicability are in use for computing the value of such integral functions. Lately, the author developed rapidly convergent infinite series representation of generalized Secant Integrals involving incomplete Gamma functions. Validity of such representation was established for zero and positive values of integral parameter a (a=0). In this paper recurrence relations for generalized Secant Integrals are derived allowing us simple approximate analytic calculation of the integral for arbitrary a values. It is demonstrated how truncated series representation can be used, as the basis for such calculations, when possibly negative a values are encountered. (author)

  17. 77 FR 59932 - Single Source Award; Exception to Competition

    Science.gov (United States)

    2012-10-01

    ... Competition AGENCY: Health Resources and Services Administration (HRSA), HHS. ACTION: Notice of Exception to Competition--Single Source Award to Texas Area Health Education Centers (AHEC) East--University of Texas...

  18. Resonant interaction of a single atom with single photons from a down-conversion source

    Science.gov (United States)

    Schuck, C.; Rohde, F.; Piro, N.; Almendros, M.; Huwer, J.; Mitchell, M. W.; Hennrich, M.; Haase, A.; Dubin, F.; Eschner, J.

    2010-01-01

    We observe the interaction of a single trapped calcium ion with single photons produced by a narrow-band, resonant down-conversion source [A. Haase , Opt. Lett. 34, 55 (2009)], employing a quantum jump scheme. Using the temperature dependence of the down-conversion spectrum and the tunability of the narrow source, absorption of the down-conversion photons is quantitatively characterized.

  19. Protecting single-photon entanglement with practical entanglement source

    Science.gov (United States)

    Zhou, Lan; Ou-Yang, Yang; Wang, Lei; Sheng, Yu-Bo

    2017-06-01

    Single-photon entanglement (SPE) is important for quantum communication and quantum information processing. However, SPE is sensitive to photon loss. In this paper, we discuss a linear optical amplification protocol for protecting SPE. Different from the previous protocols, we exploit the practical spontaneous parametric down-conversion (SPDC) source to realize the amplification, for the ideal entanglement source is unavailable in current quantum technology. Moreover, we prove that the amplification using the entanglement generated from SPDC source as auxiliary is better than the amplification assisted with single photons. The reason is that the vacuum state from SPDC source will not affect the amplification, so that it can be eliminated automatically. This protocol may be useful in future long-distance quantum communications.

  20. Design and simulations of highly efficient single-photon sources

    DEFF Research Database (Denmark)

    Gregersen, Niels; de Lasson, Jakob Rosenkrantz; Mørk, Jesper

    The realization of the highly-efficient single-photon source represents not only an experimental, but also a numerical challenge. We will present the theory of the waveguide QED approach, the design challenges and the current limitations. Additionally, the important numerical challenges in the si......The realization of the highly-efficient single-photon source represents not only an experimental, but also a numerical challenge. We will present the theory of the waveguide QED approach, the design challenges and the current limitations. Additionally, the important numerical challenges...

  1. Resonant interaction of a single atom with single photons from a down-conversion source

    International Nuclear Information System (INIS)

    Schuck, C.; Rohde, F.; Piro, N.; Almendros, M.; Huwer, J.; Mitchell, M. W.; Hennrich, M.; Haase, A.; Dubin, F.; Eschner, J.

    2010-01-01

    We observe the interaction of a single trapped calcium ion with single photons produced by a narrow-band, resonant down-conversion source [A. Haase et al., Opt. Lett. 34, 55 (2009)], employing a quantum jump scheme. Using the temperature dependence of the down-conversion spectrum and the tunability of the narrow source, absorption of the down-conversion photons is quantitatively characterized.

  2. Enhancement of Single-Photon Sources with Metamaterials

    Science.gov (United States)

    Shalaginov, M. Y.; Bogdanov, S.; Vorobyov, V. V.; Lagutchev, A. S.; Kildishev, A. V.; Akimov, A. V.; Boltasseva, A.; Shalaev, V. M.

    2015-06-01

    Scientists are looking for new, breakthrough solutions that can greatly advance computing and networking systems. These solutions will involve quantum properties of matter and light as promised by the ongoing experimental and theoretical work in the areas of quantum computation and communication. Quantum photonics is destined to play a central role in the development of such technologies due to the high transmission capacity and outstanding low-noise properties of photonic information channels. Among the vital problems to be solved in this direction, are efficient generation and collection of single photons. One approach to tackle these problems is based on engineering emission properties of available single-photon sources using metamaterials. Metamaterials are artificially engineered structures with sub-wavelength features whose optical properties go beyond the limitations of conventional materials. As promising single-photon sources, we have chosen nitrogen-vacancy (NV) color centers in diamond, which are capable to operate stably in a single-photon regime at room temperature in a solid state environment. In this chapter, we report both theoretical and experimental studies of the radiation from a nanodiamond single NV center placed near a hyperbolic metamaterial (HMM). In particular, we derive the reduction of excited-state lifetime and the enhancement of collected single-photon emission rate and compare them with the experimental observations. These results could be of great impact for future integrated quantum sources, especially owing to a CMOS-compatible approach to HMM synthesis.

  3. Compressive sensing sectional imaging for single-shot in-line self-interference incoherent holography

    Science.gov (United States)

    Weng, Jiawen; Clark, David C.; Kim, Myung K.

    2016-05-01

    A numerical reconstruction method based on compressive sensing (CS) for self-interference incoherent digital holography (SIDH) is proposed to achieve sectional imaging by single-shot in-line self-interference incoherent hologram. The sensing operator is built up based on the physical mechanism of SIDH according to CS theory, and a recovery algorithm is employed for image restoration. Numerical simulation and experimental studies employing LEDs as discrete point-sources and resolution targets as extended sources are performed to demonstrate the feasibility and validity of the method. The intensity distribution and the axial resolution along the propagation direction of SIDH by angular spectrum method (ASM) and by CS are discussed. The analysis result shows that compared to ASM the reconstruction by CS can improve the axial resolution of SIDH, and achieve sectional imaging. The proposed method may be useful to 3D analysis of dynamic systems.

  4. Piling up technology of goods irradiated by single plate source

    International Nuclear Information System (INIS)

    Xia Hezhou; Chen Yuxia; Cao Hongyun; Lin Yong; Zhou guoquan

    1999-01-01

    In the irradiation process of piling up goods in static state, four irradiation working sites and single plate source was adopted. The results showed that piling up in this way remarkably raised the irradiation quality of goods. The utilization rate of radioactive ray reached 22.27%

  5. Effect of Loss on Multiplexed Single-Photon Sources (Open Access Publisher’s Version)

    Science.gov (United States)

    2015-04-28

    theCreative CommonsAttribution 3.0 licence . Any further distribution of this workmustmaintain attribution to the author(s) and the title of thework...themultiplexed (MUX) single-photon source [14], which uses an array ofHSPSs, delay lines, electronics for classical logic operations , and an active...the squeezing parameter or the loss in the idler arm. In section 3wewill show that a practicalmultiplexed sourcewill require operation in the strong

  6. Refined source apportionment of coal combustion sources by using single particle mass spectrometry.

    Science.gov (United States)

    Xu, Jiao; Wang, Haiting; Li, Xiujian; Li, Yue; Wen, Jie; Zhang, Jinsheng; Shi, Xurong; Li, Mei; Wang, Wei; Shi, Guoliang; Feng, Yinchang

    2018-06-15

    In this study, samples of three typical coal combustion source types, including Domestic bulk coal combustion (DBCC), Heat supply station (HSS), and Power plant (PP) were sampled and large sets of their mass spectra were obtained and analyzed by SPAMS during winter in a megacity in China. A primary goal of this study involves determining representative size-resolved single particle mass spectral signatures of three source types that can be used in source apportionment activities. Chemical types describe the majority of the particles of each source type were extracted by ART-2a algorithm with distinct size characteristics, and the corresponding tracer signals were identified. Mass spectral signatures from three source types were different from each other, and the tracer signals were effective in distinguishing different source types. A high size-resolution source apportionment method were proposed in this study through matching sources' mass spectral signatures to particle spectra in a twelve days ambient sampling to source apportion the particles. Contributions of three source types got different size characteristics, as HSS source got higher contribution in smaller sizes, But PP source got higher contributions as size increased. Source contributions were also quantified during two typical haze episodes, and results indicated that HSS source (for central-heating) and DBCC source (for domestic heating and cooking) may contribute evidently to pollution formation. Copyright © 2018. Published by Elsevier B.V.

  7. Improved design of proton source and low energy beam transport line for European Spallation Source

    Science.gov (United States)

    Neri, L.; Celona, L.; Gammino, S.; Mascali, D.; Castro, G.; Torrisi, G.; Cheymol, B.; Ponton, A.; Galatà, A.; Patti, G.; Gozzo, A.; Lega, L.; Ciavola, G.

    2014-02-01

    The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

  8. Improved design of proton source and low energy beam transport line for European Spallation Source

    Energy Technology Data Exchange (ETDEWEB)

    Neri, L., E-mail: neri@lns.infn.it; Celona, L.; Gammino, S.; Mascali, D.; Castro, G.; Ciavola, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Torrisi, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Ingegneria dell’Informazione, delle Infrastrutture e dell’Energia Sostenibile, Università Mediterranea di Reggio Calabria, Via Graziella, 89122 Reggio Calabria (Italy); Cheymol, B.; Ponton, A. [European Spallation Source ESS AB, Lund (Sweden); Galatà, A. [Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Viale dell' università 2, 35020 Legnaro (Italy); Patti, G. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Viale dell' università 2, 35020 Legnaro (Italy); Gozzo, A.; Lega, L. [Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare, Via S. Sofia 62, 95123 Catania (Italy); Dipartimento di Ingegneria Informatica e delle Telecomunicazioni, Università degli Studi di Catania, Viale Andrea Doria 6, 95123 Catania (Italy)

    2014-02-15

    The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

  9. Spatial and frequency domain ring source models for the single muscle fiber action potential

    DEFF Research Database (Denmark)

    Henneberg, Kaj-åge; R., Plonsey

    1994-01-01

    In the paper, single-fibre models for the extracellular action potential are developed that will allow the potential to the evaluated at an arbitrary field point in the extracellular space. Fourier-domain models are restricted in that they evaluate potentials at equidistant points along a line...... parallel to the fibre axis. Consequently, they cannot easily evaluate the potential at the boundary nodes of a boundary-element electrode model. The Fourier-domain models employ axial-symmetric ring source models, and thereby provide higher accuracy that the line source model, where the source is lumped...... including anisotropy show that the spatial models require extreme care in the integration procedure owing to the singularity in the weighting functions. With adequate sampling, the spatial models can evaluate extracellular potentials with high accuracy....

  10. Customized Pull Systems for Single-Product Flow Lines

    NARCIS (Netherlands)

    Gaury, E.G.A.; Kleijnen, J.P.C.; Pierreval, H.

    1998-01-01

    Traditionally pull production systems are managed through classic control systems such as Kanban, Conwip, or Base stock, but this paper proposes ‘customized’ pull control. Customization means that a given production line is managed through a pull control system that in principle connects each stage

  11. Dual-Source Linear Energy Prediction (LINE-P) Model in the Context of WSNs.

    Science.gov (United States)

    Ahmed, Faisal; Tamberg, Gert; Le Moullec, Yannick; Annus, Paul

    2017-07-20

    Energy harvesting technologies such as miniature power solar panels and micro wind turbines are increasingly used to help power wireless sensor network nodes. However, a major drawback of energy harvesting is its varying and intermittent characteristic, which can negatively affect the quality of service. This calls for careful design and operation of the nodes, possibly by means of, e.g., dynamic duty cycling and/or dynamic frequency and voltage scaling. In this context, various energy prediction models have been proposed in the literature; however, they are typically compute-intensive or only suitable for a single type of energy source. In this paper, we propose Linear Energy Prediction "LINE-P", a lightweight, yet relatively accurate model based on approximation and sampling theory; LINE-P is suitable for dual-source energy harvesting. Simulations and comparisons against existing similar models have been conducted with low and medium resolutions (i.e., 60 and 22 min intervals/24 h) for the solar energy source (low variations) and with high resolutions (15 min intervals/24 h) for the wind energy source. The results show that the accuracy of the solar-based and wind-based predictions is up to approximately 98% and 96%, respectively, while requiring a lower complexity and memory than the other models. For the cases where LINE-P's accuracy is lower than that of other approaches, it still has the advantage of lower computing requirements, making it more suitable for embedded implementation, e.g., in wireless sensor network coordinator nodes or gateways.

  12. Single-phased Fault Location on Transmission Lines Using Unsynchronized Voltages

    Directory of Open Access Journals (Sweden)

    ISTRATE, M.

    2009-10-01

    Full Text Available The increased accuracy into the fault's detection and location makes it easier for maintenance, this being the reason to develop new possibilities for a precise estimation of the fault location. In the field literature, many methods for fault location using voltages and currents measurements at one or both terminals of power grids' lines are presented. The double-end synchronized data algorithms are very precise, but the current transformers can limit the accuracy of these estimations. The paper presents an algorithm to estimate the location of the single-phased faults which uses only voltage measurements at both terminals of the transmission lines by eliminating the error due to current transformers and without introducing the restriction of perfect data synchronization. In such conditions, the algorithm can be used with the actual equipment of the most power grids, the installation of phasor measurement units with GPS system synchronized timer not being compulsory. Only the positive sequence of line parameters and sources are used, thus, eliminating the incertitude in zero sequence parameter estimation. The algorithm is tested using the results of EMTP-ATP simulations, after the validation of the ATP models on the basis of registered results in a real power grid.

  13. Novel single photon sources for new generation of quantum communications

    Science.gov (United States)

    2017-06-13

    state single photon sources that was published in Nature Photonics in October 2016. 15. SUBJECT TERMS diamond color center, diamond, AOARD 16. SECURITY...platform for quantum emitters. We developed means to increase their density, developed basic methods to engineer them, and demonstrate coupling to...manipulation of a silicon vacancy color cent er in a nanodiamond. We demonstrate ultra fast coherent control of a photon, that make s this defect

  14. Ionization dual-zone static detector having single radioactive source

    International Nuclear Information System (INIS)

    Ried, L. Jr.; Wade, A.L.

    1977-01-01

    This ionization detector or combustion product detector includes a single radioactive source located in an ionization chamber, and the ionization chamber includes portions comprising a reference zone and a signal zone. Electrical circuitry connected to the reference and signal zones provides an output signal directly related to changes in voltages across the signal zone in relation to the amount of particulates of combustion present in the ionization chamber

  15. Chebyshev approximations for the transmission integral for one single line in Moessbauer spectroscopy

    International Nuclear Information System (INIS)

    Flores-Lamas, H.

    1994-01-01

    An analytic expansion, to arbitrary accuracy, of the transmission integral (TI) for a single Moessbauer line is presented. This serves for calculating the effective thickness (T a ) of an absorber in Moessbauer spectroscopy even for T a >10. The new analytic expansion arises from substituting in the TI expression the exponential function by a Chebyshev polynomials series. A very fast converging series for TI is obtained and used as a test function in a least squares fit to a simulated spectrum. The test yields satisfactory results. The area and height parameters calculated were found to be in good agreement with earlier results. The present analytic method assumes that the source and absorber widths are different. ((orig.))

  16. The source of the helium visible lines in η Carinae

    Science.gov (United States)

    Kashi, Amit; Soker, Noam

    2007-10-01

    We assume that the helium-I lines emitted by the massive binary system η Carinae are formed in the acceleration zone of the less-massive secondary star. We calculate the Doppler shift of the lines as a function of orbital phase and of several parameters of the binary system. We find that a good fit is obtained if the helium lines are formed in the region where the secondary wind speed is vzone = 430 km s -1. The acceptable binary eccentricity is in the range 0.90 ≲ e ≲ 0.95, and the inclination angle (the angle between a line perpendicular to the orbital plane and the line of sight) is in the range 40° ≲ i ≲ 55°. Lower values of e require higher values of i, and vice versa. The binary system is oriented such that the secondary star is in our direction (closer to us) during periastron passage. The orbital motion can account in part to the Doppler shift of the peak in X-ray emission.

  17. Reflected pulse damping between charge source and shaping line

    International Nuclear Information System (INIS)

    Bukharov, V.F.; Gerasimov, A.I.; Fedotkin, A.S.

    1987-01-01

    A coaxial device to tranfer electric energy from a pulsed generator to a low-impedance shaping line whose commutation brings about powerful short voltage pulses is described. To damp pulses the internal conductor of the device is enveloped by the element of volumetrically resitant material, and controlled discharge are placed between the external conductor of the device and the element. The device operated efficiency when the radical lines were charged from the Arkadiev-Marx generator during 1 μs up to 500 kV

  18. Localizing gravitational wave sources with single-baseline atom interferometers

    Science.gov (United States)

    Graham, Peter W.; Jung, Sunghoon

    2018-02-01

    Localizing sources on the sky is crucial for realizing the full potential of gravitational waves for astronomy, astrophysics, and cosmology. We show that the midfrequency band, roughly 0.03 to 10 Hz, has significant potential for angular localization. The angular location is measured through the changing Doppler shift as the detector orbits the Sun. This band maximizes the effect since these are the highest frequencies in which sources live for several months. Atom interferometer detectors can observe in the midfrequency band, and even with just a single baseline they can exploit this effect for sensitive angular localization. The single-baseline orbits around the Earth and the Sun, causing it to reorient and change position significantly during the lifetime of the source, and making it similar to having multiple baselines/detectors. For example, atomic detectors could predict the location of upcoming black hole or neutron star merger events with sufficient accuracy to allow optical and other electromagnetic telescopes to observe these events simultaneously. Thus, midband atomic detectors are complementary to other gravitational wave detectors and will help complete the observation of a broad range of the gravitational spectrum.

  19. Non-uniform dwell times in line source high dose rate brachytherapy: physical and radiobiological considerations

    International Nuclear Information System (INIS)

    Jones, B.; Tan, L.T.; Freestone, G.; Bleasdale, C.; Myint, S.; Littler, J.

    1994-01-01

    The ability to vary source dwell times in high dose rate (HDR) brachytherapy allows for the use of non-uniform dwell times along a line source. This may have advantages in the radical treatment of tumours depending on individual tumour geometry. This study investigates the potential improvements in local tumour control relative to adjacent normal tissue isoeffects when intratumour source dwell times are increased along the central portion of a line source (technique A) in radiotherapy schedules which include a relatively small component of HDR brachytherapy. Such a technique is predicted to increase the local control for tumours of diameters ranging between 2 cm and 4 cm by up to 11% compared with a technique in which there are uniform dwell times along the line source (technique B). There is no difference in the local control rates for the two techniques when used to treat smaller tumours. Normal tissue doses are also modified by the technique used. Technique A produces higher normal tissue doses at points perpendicular to the centre of the line source and lower dose at points nearer the ends of the line source if the prescription point is not in the central plane of the line source. Alternatively, if the dose is prescribed at a point in the central plane of the line source, the dose at all the normal tissue points are lower when technique A is used. (author)

  20. In-Line Fiber Optic Interferometric Sensors in Single-Mode Fibers

    OpenAIRE

    De-Wen Duan; Min Liu; Di Wu; Tao Zhu

    2012-01-01

    In-line fiber optic interferometers have attracted intensive attention for their potential sensing applications in refractive index, temperature, pressure and strain measurement, etc. Typical in-line fiber-optic interferometers are of two types: Fabry-Perot interferometers and core-cladding-mode interferometers. It’s known that the in-line fiber optic interferometers based on single-mode fibers can exhibit compact structures, easy fabrication and low cost. In this paper, ...

  1. Methods of forming single source precursors, methods of forming polymeric single source precursors, and single source precursors formed by such methods

    Science.gov (United States)

    Fox, Robert V.; Rodriguez, Rene G.; Pak, Joshua J.; Sun, Chivin; Margulieux, Kelsey R.; Holland, Andrew W.

    2014-09-09

    Methods of forming single source precursors (SSPs) include forming intermediate products having the empirical formula 1/2{L.sub.2N(.mu.-X).sub.2M'X.sub.2}.sub.2, and reacting MER with the intermediate products to form SSPs of the formula L.sub.2N(.mu.-ER).sub.2M'(ER).sub.2, wherein L is a Lewis base, M is a Group IA atom, N is a Group IB atom, M' is a Group IIIB atom, each E is a Group VIB atom, each X is a Group VIIA atom or a nitrate group, and each R group is an alkyl, aryl, vinyl, (per)fluoro alkyl, (per)fluoro aryl, silane, or carbamato group. Methods of forming polymeric or copolymeric SSPs include reacting at least one of HE.sup.1R.sup.1E.sup.1H and MER with one or more substances having the empirical formula L.sub.2N(.mu.-ER).sub.2M'(ER).sub.2 or L.sub.2N(.mu.-X).sub.2M'(X).sub.2 to form a polymeric or copolymeric SSP. New SSPs and intermediate products are formed by such methods.

  2. Methods of forming single source precursors, methods of forming polymeric single source precursors, and single source precursors and intermediate products formed by such methods

    Science.gov (United States)

    Fox, Robert V.; Rodriguez, Rene G.; Pak, Joshua J.; Sun, Chivin; Margulieux, Kelsey R.; Holland, Andrew W.

    2012-12-04

    Methods of forming single source precursors (SSPs) include forming intermediate products having the empirical formula 1/2{L.sub.2N(.mu.-X).sub.2M'X.sub.2}.sub.2, and reacting MER with the intermediate products to form SSPs of the formula L.sub.2N(.mu.-ER).sub.2M'(ER).sub.2, wherein L is a Lewis base, M is a Group IA atom, N is a Group IB atom, M' is a Group IIIB atom, each E is a Group VIB atom, each X is a Group VIIA atom or a nitrate group, and each R group is an alkyl, aryl, vinyl, (per)fluoro alkyl, (per)fluoro aryl, silane, or carbamato group. Methods of forming polymeric or copolymeric SSPs include reacting at least one of HE.sup.1R.sup.1E.sup.1H and MER with one or more substances having the empirical formula L.sub.2N(.mu.-ER).sub.2M'(ER).sub.2 or L.sub.2N(.mu.-X).sub.2M'(X).sub.2 to form a polymeric or copolymeric SSP. New SSPs and intermediate products are formed by such methods.

  3. The VTTVIS line imaging spectrometer - principles, error sources, and calibration

    DEFF Research Database (Denmark)

    Jørgensen, R.N.

    2002-01-01

    Hyperspectral imaging with a spatial resolution of a few mm2 has proved to have a great potential within crop and weed classification and also within nutrient diagnostics. A commonly used hyperspectral imaging system is based on the Prism-Grating-Prism(PGP) principles produced by Specim Ltd...... work describing the basic principles, potential error sources, and/or adjustment and calibration procedures. This report fulfils the need for such documentationwith special focus on the system at KVL. The PGP based system has several severe error sources, which should be removed prior any analysis...

  4. Improvement of Source Number Estimation Method for Single Channel Signal.

    Directory of Open Access Journals (Sweden)

    Zhi Dong

    Full Text Available Source number estimation methods for single channel signal have been investigated and the improvements for each method are suggested in this work. Firstly, the single channel data is converted to multi-channel form by delay process. Then, algorithms used in the array signal processing, such as Gerschgorin's disk estimation (GDE and minimum description length (MDL, are introduced to estimate the source number of the received signal. The previous results have shown that the MDL based on information theoretic criteria (ITC obtains a superior performance than GDE at low SNR. However it has no ability to handle the signals containing colored noise. On the contrary, the GDE method can eliminate the influence of colored noise. Nevertheless, its performance at low SNR is not satisfactory. In order to solve these problems and contradictions, the work makes remarkable improvements on these two methods on account of the above consideration. A diagonal loading technique is employed to ameliorate the MDL method and a jackknife technique is referenced to optimize the data covariance matrix in order to improve the performance of the GDE method. The results of simulation have illustrated that the performance of original methods have been promoted largely.

  5. Calculated neutron dose rates and flux densities from implantable californium-252 point and line sources.

    Science.gov (United States)

    Shapiro, A; Schwartz, B; Windham, J P; Kereiakes, J G

    1976-01-01

    The results of neutron-transport flux-density and dose rate calculations for implantable Californium-252 point and line sources in essentially infinite tissue-equivalent material are presented. The point-source flux densities were obtained from a discrete ordinates calculation, and the point dose rates were established by multiplying the flux densities by their appropriate kerma factors. Line-source dose rates were evaluated by integrating the point dose rates over the length of the line source. Dose-rate data are given within a 20 X 20-cm region from the source center for source lengths of 1.5, 2, and 3 cm. The dose rates established by these calculations showed good agreement with an independent Monte Carlo calculation. Detailed point-source flux-density data as a function of energy and position are also given.

  6. Uncharted constellations asterisms, single-source and rebrands

    CERN Document Server

    Barentine, John C

    2016-01-01

    This book compiles an array of interesting constellations that fell by the wayside before the IAU established the modern canon of constellations. That decision left out lesser known ones whose history is nevertheless interesting, but at last author John Barentine is giving them their due. This book is a companion to "The Alternate Constellations", highlighting the more obscure configurations.  The 16 constellations found in this volume fall into one or more of three broad categories: asterims, such as the Big Dipper in Ursa Major; single-sourced constellations introduced on surviving charts by a cartographer perhaps currying the favor of sponsors; and re-brands, new figures meant to displace existing constellations, often for an ideological reason. All of them reveal something unique about the development of humanity's map of the sky. .

  7. Single bunch transfer system for the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Sheehan, J.; Singh, O.; Rambo, W.

    1983-01-01

    The accelerator system at the National Synchrotron Light Source consists of an S-band 85 MeV linac and three synchrotron rings. The electron beam from the linac is accelerated by the booster ring to 600 MeV and transferred to one of the two storage rings. The smaller of the two rings operates between 300 and 800 MeV emtting photons in the vacuum ultraviolet (VUV), while the larger storage ring operates up to 2.5 GeV and emits photons in the x-ray spectrum. A system is described for loading the storage rings by filling a single-phase space bunch in the booster ring and transferring it at the end of each booster cycle into a selected bucket in one of the storage rings. By controlling the timing of the transfer on successive transfer cycles, many fill patterns may be obtained

  8. Ion Source Multiplexing on a Single Mass Spectrometer.

    Science.gov (United States)

    Kostyukevich, Yury; Nikolaev, Eugene

    2018-03-06

    We present the simple approach for the combination of different ion sources on a single mass spectrometer without any interference between them. Each ion source can be positioned as far as 1 m from the mass spectrometer; ions are transported by the means of flexible copper tubes, which are connected, to the separate inlet capillaries. Special valves enable switching channels on and off. Using this approach, we successfully combined native electrospray ionization (ESI), regular ESI, β-electrons ionization, and atmospheric pressure photoionization (APPI) of thermally desorbed vapors of petroleum on a single mass spectrometer. In addition, separate channels allow infusing internal calibration mixture or performing ion molecular reactions in one channel and using the other as a reference. Using this idea, we have developed an original sequential window acquisition of all theoretical mass spectra (SWATH MS) approach in which peptide ions are transported in different channels, one of which is heated to high temperature so that ions are thermally fragmented, and the other channel ensures the presence of nonfragmented ions in the spectrum. Also, we demonstrated the possibility to perform gas phase H/D exchange reaction in one channel and using another as reference. Use of valves makes it possible to exclude any interference between them. Thus, we have demonstrated the possibility to create a multichannel system in which ions would be transported through several inlet tubes in which different ion molecular reactions such as Paternò-Büchi, ozonation, or H/D exchange will occur. Comparison of mass spectra recorded when different channels are open will provide structural and chemical information about unknown species.

  9. Direct Seeded Single Frequency mid-IR OPA all Passive Light Source

    DEFF Research Database (Denmark)

    Høgstedt, Lasse; Tidemand-Lichtenberg, Peter; Pedersen, Christian

    2013-01-01

    We present a two stage pulsed mid-infrared light source based on nonlinear downconversion of light. The light source is single frequency, tunable, all passive, single moded and build with standard optical components....

  10. Artificial lateral-line system for imaging dipole sources using Beamforming techniques

    NARCIS (Netherlands)

    Dagamseh, A.M.K.; Wiegerink, Remco J.; Lammerink, Theodorus S.J.; Krijnen, Gijsbertus J.M.

    In nature, fish have the ability to localize prey, school, navigate, etc. using the lateral-line organ [1]. Here we present the use of biomimetic artificial hair-based flow-sensors arranged as lateral-line system in combination with beamforming techniques for dipole source localization in air.

  11. Point defects in lines in single crystalline phosphorene: directional migration and tunable band gaps.

    Science.gov (United States)

    Li, Xiuling; Ma, Liang; Wang, Dayong; Zeng, Xiao Cheng; Wu, Xiaojun; Yang, Jinlong

    2016-10-20

    Extended line defects in two-dimensional (2D) materials can play an important role in modulating their electronic properties. During the experimental synthesis of 2D materials, line defects are commonly generated at grain boundaries between domains of different orientations. In this work, twelve types of line-defect structures in single crystalline phosphorene are examined by using first-principles calculations. These line defects are typically formed via migration and aggregation of intrinsic point defects, including the Stone-Wales (SW), single or double vacancy (SV or DV) defects. Our calculated results demonstrate that the migration of point defects in phosphorene is anisotropic, for instance, the lowest migration energy barriers are 1.39 (or 0.40) and 2.58 (or 0.49) eV for SW (or SV) defects in zigzag and armchair directions, respectively. The aggregation of point defects into lines is energetically favorable compared with the separated point defects in phosphorene. In particular, the axis of line defects in phosphorene is direction-selective, depending on the composed point defects. The presence of line defects effectively modulates the electronic properties of phosphorene, rendering the defect-containing phosphorene either metallic or semiconducting with a tunable band gap. Of particular interest is the fact that the SV-based line defect can behave as a metallic wire, suggesting a possibility to fabricate a circuit with subnanometer widths in the semiconducting phosphorene for nanoscale electronic application.

  12. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    Energy Technology Data Exchange (ETDEWEB)

    Joenemalm, C.; Malen, K

    1966-10-15

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources.

  13. Nomogram for Determining Shield Thickness for Point and Line Sources of Gamma Rays

    International Nuclear Information System (INIS)

    Joenemalm, C.; Malen, K

    1966-10-01

    A set of nomograms is given for the determination of the required shield thickness against gamma radiation. The sources handled are point and infinite line sources with shields of Pb, Fe, magnetite concrete (p = 3.6), ordinary concrete (p = 2.3) or water. The gamma energy range covered is 0.5 - 10 MeV. The nomograms are directly applicable for source and dose points on the surfaces of the shield. They can easily be extended to source and dose points in other positions by applying a geometrical correction. Also included are data for calculation of the source strength for the most common materials and for fission product sources

  14. Parallel superconducting strip-line detectors: reset behaviour in the single-strip switch regime

    International Nuclear Information System (INIS)

    Casaburi, A; Heath, R M; Tanner, M G; Hadfield, R H; Cristiano, R; Ejrnaes, M; Nappi, C

    2014-01-01

    Superconducting strip-line detectors (SSLDs) are an important emerging technology for the detection of single molecules in time-of-flight mass spectrometry (TOF-MS). We present an experimental investigation of a SSLD laid out in a parallel configuration, designed to address selected single strip-lines operating in the single-strip switch regime. Fast laser pulses were tightly focused onto the device, allowing controllable nucleation of a resistive region at a specific location and study of the subsequent device response dynamics. We observed that in this regime, although the strip-line returns to the superconducting state after triggering, no effective recovery of the bias current occurs, in qualitative agreement with a phenomenological circuit simulation that we performed. Moreover, from theoretical considerations and by looking at the experimental pulse amplitude distribution histogram, we have the first confirmation of the fact that the phenomenological London model governs the current redistribution in these large area devices also after detection events. (paper)

  15. Parallel superconducting strip-line detectors: reset behaviour in the single-strip switch regime

    Science.gov (United States)

    Casaburi, A.; Heath, R. M.; Tanner, M. G.; Cristiano, R.; Ejrnaes, M.; Nappi, C.; Hadfield, R. H.

    2014-04-01

    Superconducting strip-line detectors (SSLDs) are an important emerging technology for the detection of single molecules in time-of-flight mass spectrometry (TOF-MS). We present an experimental investigation of a SSLD laid out in a parallel configuration, designed to address selected single strip-lines operating in the single-strip switch regime. Fast laser pulses were tightly focused onto the device, allowing controllable nucleation of a resistive region at a specific location and study of the subsequent device response dynamics. We observed that in this regime, although the strip-line returns to the superconducting state after triggering, no effective recovery of the bias current occurs, in qualitative agreement with a phenomenological circuit simulation that we performed. Moreover, from theoretical considerations and by looking at the experimental pulse amplitude distribution histogram, we have the first confirmation of the fact that the phenomenological London model governs the current redistribution in these large area devices also after detection events.

  16. Study on radiation dose in single-source and triple-source helical cone-beam scanning

    International Nuclear Information System (INIS)

    Lv Yang; Zhao Jun; Zhuang Tiange; Chen Kemin

    2008-01-01

    In this work we discuss the radiation area of helical cone-beam scanning and present the formulae to calculate the radiation dosage of single-source and triple-source helical cone-beam scanning. The results reveal that the radiation dose of triple-source helical cone-beam scanning is equal to that of single-source helical cone-beam scanning. (authors)

  17. The development of a tunable, single-frequency ultraviolet laser source for UV filtered Rayleigh scattering

    Science.gov (United States)

    Finkelstein, N.; Gambogi, J.; Lempert, Walter R.; Miles, Richard B.; Rines, G. A.; Finch, A.; Schwarz, R. A.

    1995-01-01

    We present the development of a flexible, high power, narrow line width, tunable ultraviolet source for diagnostic application. By frequency tripling the output of a pulsed titanium-sapphire laser, we achieve broadly tunable (227-360 nm) ultraviolet light with high quality spatial and spectral resolution. We also present the characterization of a mercury vapor cell which provides a narrow band, sharp edge absorption filter at 253.7 nm. These two components form the basis for the extension of the Filtered Rayleigh Scattering technique into the ultraviolet. The UV-FRS system is comprised of four pieces: a single frequency, cw tunable Ti:Sapphire seeding source; a high-powered pulsed Ti:Sapphire oscillator; a third harmonic generator system; and an atomic mercury vapor filter. In this paper we discuss the development and characterization of each of these elements.

  18. Line-edge roughness induced single event transient variation in SOI FinFETs

    International Nuclear Information System (INIS)

    Wu Weikang; An Xia; Jiang Xiaobo; Chen Yehua; Liu Jingjing; Zhang Xing; Huang Ru

    2015-01-01

    The impact of process induced variation on the response of SOI FinFET to heavy ion irradiation is studied through 3-D TCAD simulation for the first time. When FinFET biased at OFF state configuration (V gs = 0, V ds = V dd ) is struck by a heavy ion, the drain collects ionizing charges under the electric field and a current pulse (single event transient, SET) is consequently formed. The results reveal that with the presence of line-edge roughness (LER), which is one of the major variation sources in nano-scale FinFETs, the device-to-device variation in terms of SET is observed. In this study, three types of LER are considered: type A has symmetric fin edges, type B has irrelevant fin edges and type C has parallel fin edges. The results show that type A devices have the largest SET variation while type C devices have the smallest variation. Further, the impact of the two main LER parameters, correlation length and root mean square amplitude, on SET variation is discussed as well. The results indicate that variation may be a concern in radiation effects with the down scaling of feature size. (paper)

  19. Compton backscattered annihilation line emission: A new diagnostic of accreting compact sources

    Science.gov (United States)

    Lingenfelter, Richard E.; Hua, Xin-Min

    1992-01-01

    It is shown that Compton scattering of 511 keV electron-positron annihilation radiation produces a line like feature at approx. 170 keV from backscattered photons. Assuming a simple model of an accretion disk around a compact source, the spectrum is explored of the spectrum of Compton scattered annihilation line emission for a range of conditions. It is further shown that such Compton baskscattering of annihilation line emission from the inner edge of an accretion disk could account for the previously unidentified 170 keV line emission and high energy continuum observed from a variable, compact source, or sources, of annihilation radiation near the Galactic Center. Identification of the observed 170 keV line as an annihilation line reflection feature provides strong new evidence that the source of the emission is an accreting compact object. Further study of these features in existing spectra and in forthcoming GRO observation of these and other sources can provide unique new diagnostics of the innermost regions of accretion disks around compact objects.

  20. The extinction to the H2 line emission in the DR 21 outflow source

    International Nuclear Information System (INIS)

    Nadeau, D.; Riopel, M.; Geballe, T.R.

    1991-01-01

    The v = 1-0 S(1) and Q(3) lines of H2 have been measured in four regions of the DR 21 H2 line-emission source, in order to determine whether the observed morphology of the emission represents the distribution of the excited H2 or is modified by nonuniform extinction across the source. The measured lines originate from the same upper level, and their ratio is a direct measure of the reddening. The line ratios show that the extinction is quite uniform across the source and that there is no correlation between the intensity and the extinction. This result implies that the gap between the two lobes of emission is not due to increased extinction but rather is a region where there is little excited H2 gas. 13 refs

  1. Single-dose and fractionated irradiation of four human lung cancer cell lines in vitro

    International Nuclear Information System (INIS)

    Brodin, O.; Lennartsson, L.; Nilsson, S.

    1991-01-01

    Four established human lung cancer cell lines were exposed to single-dose irradiation. The survival curves of 2 small cell lung carcinomas (SCLC) were characterized by a limited capacity for repair with small and moderate shoulders with extrapolation numbers (n) of 1.05 and 1.60 respectively. Two non-small cell lung carcinoma (NSCLC) cell lines, one squamous cell (SQCLC) and one large cell (LCLC) had large shoulders with n-values of 73 and 15 respectively. The radiosensitivity when measured as D 0 did not, however, differ as much from cell line to cell line, with values from 1.22 to 1.65. The surviving fraction after 2 Gy (SF2) was 0.24 and 0.42 respectively in the SCLC cell lines and 0.90 and 0.88 respectively in the NSCLC cell lines. Fractionated irradiation delivered according to 3 different schedules was also investigated. All the schedules delivered a total dose of 10 Gy in 5 days and were applied in 1, 2 and 5 Gy dose fractions respectively. Survival followed the pattern found after single-dose irradiation; it was lowest in the SCLC cell line with the lowest SF and highest in the two NSCLC cell lines. In the SCLC cell lines all schedules were approximately equally efficient. In the LCLC and in the SQCLC cell lines, the 5 Gy schedule killed more cells than the 1 and 2 Gy schedules. The results indicate that the size of the shoulder of the survival curve is essential when choosing the most tumoricidal fractionation schedule. (orig.)

  2. Temporal resolution and motion artifacts in single-source and dual-source cardiac CT

    International Nuclear Information System (INIS)

    Schöndube, Harald; Allmendinger, Thomas; Stierstorfer, Karl; Bruder, Herbert; Flohr, Thomas

    2013-01-01

    Purpose: The temporal resolution of a given image in cardiac computed tomography (CT) has so far mostly been determined from the amount of CT data employed for the reconstruction of that image. The purpose of this paper is to examine the applicability of such measures to the newly introduced modality of dual-source CT as well as to methods aiming to provide improved temporal resolution by means of an advanced image reconstruction algorithm. Methods: To provide a solid base for the examinations described in this paper, an extensive review of temporal resolution in conventional single-source CT is given first. Two different measures for assessing temporal resolution with respect to the amount of data involved are introduced, namely, either taking the full width at half maximum of the respective data weighting function (FWHM-TR) or the total width of the weighting function (total TR) as a base of the assessment. Image reconstruction using both a direct fan-beam filtered backprojection with Parker weighting as well as using a parallel-beam rebinning step are considered. The theory of assessing temporal resolution by means of the data involved is then extended to dual-source CT. Finally, three different advanced iterative reconstruction methods that all use the same input data are compared with respect to the resulting motion artifact level. For brevity and simplicity, the examinations are limited to two-dimensional data acquisition and reconstruction. However, all results and conclusions presented in this paper are also directly applicable to both circular and helical cone-beam CT. Results: While the concept of total TR can directly be applied to dual-source CT, the definition of the FWHM of a weighting function needs to be slightly extended to be applicable to this modality. The three different advanced iterative reconstruction methods examined in this paper result in significantly different images with respect to their motion artifact level, despite exactly the same

  3. Single-Photon Source for Quantum Information Based on Single Dye Molecule Fluorescence in Liquid Crystal Host

    International Nuclear Information System (INIS)

    Lukishova, S.G.; Knox, R.P.; Freivald, P.; McNamara, A.; Boyd, R.W.; Stroud, Jr. C.R.; Schmid, A.W.; Marshall, K.L.

    2006-01-01

    This paper describes a new application for liquid crystals: quantum information technology. A deterministically polarized single-photon source that efficiently produces photons exhibiting antibunching is a pivotal hardware element in absolutely secure quantum communication. Planar-aligned nematic liquid crystal hosts deterministically align the single dye molecules which produce deterministically polarized single (antibunched) photons. In addition, 1-D photonic bandgap cholesteric liquid crystals will increase single-photon source efficiency. The experiments and challenges in the observation of deterministically polarized fluorescence from single dye molecules in planar-aligned glassy nematic-liquid-crystal oligomer as well as photon antibunching in glassy cholesteric oligomer are described for the first time

  4. Spherical Projection Based Straight Line Segment Extraction for Single Station Terrestrial Laser Point Cloud

    Directory of Open Access Journals (Sweden)

    ZHANG Fan

    2015-06-01

    Full Text Available Due to the discrete distribution computing errors and lack of adaptability are ubiquitous in the current straight line extraction for TLS data methods. A 3D straight line segment extraction method is proposed based on spherical projection for single station terrestrial laser point clouds. Firstly, horizontal and vertical angles of each laser point are calculated by means of spherical coordinates, intensity panoramic image according to the two angles is generated. Secondly, edges which include straight line features are detected from intensity panoramic image by using of edge detection algorithm. Thirdly, great circles are detected from edges of panoramic image using spherical Hough transform. According to the axiom that a straight line segment in 3D space is a spherical great circle after spherical projection, detecting great circles from spherical projected data sets is essentially detecting straight line segments from 3D data sets without spherical projection. Finally, a robust 3D straight line fitting method is employed to fitting the straight lines and calculating parameters of the straight line segments. Experiments using different data sets and comparison with other methods show the accuracy and applicability of the proposed method.

  5. RADIAL VELOCITIES OF GALACTIC O-TYPE STARS. II. SINGLE-LINED SPECTROSCOPIC BINARIES

    International Nuclear Information System (INIS)

    Williams, S. J.; Gies, D. R.; Hillwig, T. C.; McSwain, M. V.; Huang, W.

    2013-01-01

    We report on new radial velocity measurements of massive stars that are either suspected binaries or lacking prior observations. This is part of a survey to identify and characterize spectroscopic binaries among O-type stars with the goal of comparing the binary fraction of field and runaway stars with those in clusters and associations. We present orbits for HDE 308813, HD 152147, HD 164536, BD–16°4826, and HDE 229232, Galactic O-type stars exhibiting single-lined spectroscopic variation. By fitting model spectra to our observed spectra, we obtain estimates for effective temperature, surface gravity, and rotational velocity. We compute orbital periods and velocity semiamplitudes for each system and note the lack of photometric variation for any system. These binaries probably appear single-lined because the companions are faint and because their orbital Doppler shifts are small compared to the width of the rotationally broadened lines of the primary.

  6. Nanofabrication of Plasmonic Circuits Containing Single Photon Sources

    DEFF Research Database (Denmark)

    Siampour, Hamidreza; Kumar, Shailesh; Bozhevolnyi, Sergey I.

    2017-01-01

    Nanofabrication of photonic components based on dielectric loaded surface plasmon polariton waveguides (DLSPPWs) excited by single nitrogen vacancy (NV) centers in nanodiamonds is demonstrated. DLSPPW circuits are built around NV containing nanodiamonds, which are certified to be single...

  7. Single step high-speed printing of continuous silver lines by laser-induced forward transfer

    Energy Technology Data Exchange (ETDEWEB)

    Puerto, D., E-mail: puerto@lp3.univ-mrs.fr [Aix-Marseille University, CNRS, LP3 laboratory Campus de Luminy, C.917, Marseille (France); Biver, E. [Aix-Marseille University, CNRS, LP3 laboratory Campus de Luminy, C.917, Marseille (France); Oxford Lasers Ltd., Unit 8, Moorbrook Park, Didcot, OX11 7HP (United Kingdom); Alloncle, A.-P.; Delaporte, Ph. [Aix-Marseille University, CNRS, LP3 laboratory Campus de Luminy, C.917, Marseille (France)

    2016-06-30

    Highlights: • We have performed an experimental study on laser micro-printing of silver nanoparticle inks. • We have achieved the printing of lines in a single pass at velocities of 17 m/s (1 MHz laser). • The ejection dynamics has been investigated by means of a time-resolved imaging technique. • The control of the donor film properties is of prime importance to print lines at high velocities. • Continuous conductive lines of silver inks are laser-printed on PET flexible substrates. - Abstract: The development of high-speed ink printing process by Laser-Induced Forward Transfer (LIFT) is of great interest for the printing community. To address the problems and the limitations of this process that have been previously identified, we have performed an experimental study on laser micro-printing of silver nanoparticle inks by LIFT and demonstrated for the first time the printing of continuous conductive lines in a single pass at velocities of 17 m/s using a 1 MHz repetition rate laser. We investigated the printing process by means of a time-resolved imaging technique to visualize the ejection dynamics of single and adjacent jets. The control of the donor film properties is of prime importance to achieve single step printing of continuous lines at high velocities. We use a 30 ps pulse duration laser with a wavelength of 343 nm and a repetition rate from 0.2 to 1 MHz. A galvanometric mirror head controls the distance between two consecutives jets by scanning the focused beam along an ink-coated donor substrate at different velocities. Droplets and lines of silver inks are laser-printed on glass and PET flexible substrates and we characterized their morphological quality by atomic force microscope (AFM) and optical microscope.

  8. Photoacoustic thermal flowmetry with a single light source

    Science.gov (United States)

    Liu, Wei; Lan, Bangxin; Hu, Leo; Chen, Ruimin; Zhou, Qifa; Yao, Junjie

    2017-09-01

    We report a photoacoustic thermal flowmetry based on optical-resolution photoacoustic microscopy (OR-PAM) using a single laser source for both thermal tagging and photoacoustic excitation. When an optically absorbing medium is flowing across the optical focal zone of OR-PAM, a small volume of the medium within the optical focus is repeatedly illuminated and heated by a train of laser pulses with a high repetition rate. The average temperature of the heated volume at each laser pulse is indicated by the photoacoustic signal excited by the same laser pulse due to the well-established linear relationship between the Grueneisen coefficient and the local temperature. The thermal dynamics of the heated medium volume, which are closely related to the flow speed, can therefore be measured from the time course of the detected photoacoustic signals. Here, we have developed a lumped mathematical model to describe the time course of the photoacoustic signals as a function of the medium's flow speed. We conclude that the rising time constant of the photoacoustic signals is linearly dependent on the flow speed. Thus, the flow speed can be quantified by fitting the measured photoacoustic signals using the derived mathematical model. We first performed proof-of-concept experiments using defibrinated bovine blood flowing in a plastic tube. The experiment results have demonstrated that the proposed method has high accuracy (˜±6%) and a wide range of measurable flow speeds. We further validated the method by measuring the blood flow speeds of the microvasculature in a mouse ear in vivo.

  9. A study on industrial gamma ray CT with a single source-detector pair

    International Nuclear Information System (INIS)

    Kim, Jong Bum; Jung, Sung Hee; Kim, Jin Sup

    2006-01-01

    Having its roots in medical applications, industrial gamma ray CT has opened up new roads for investigating and modeling industrial processes. Using a line of research related to industrial gamma ray CT, the authors set up a system of single source and detector gamma transmission tomography for wood timber and a packed bed phantom. The hardware of the CT system consists of two servo motors, a data logger, a computer, a radiation source and a radiation detector. One motor simultaneously moves the source and the detector for a parallel beam scanning, whereas the other motor rotates the scan table at a preset projection angle. The image is reconstructed from the measured projections by the filtered back projection method. The phantom was designed to simulate a cross section of a packed bed with a void. The radiation source was 20mCi of Cs-137 and the detector was a 1 inch x 1 inch NaI (TI) scintillator shielded by a lead collimator. The experimental gamma ray CT image has sufficient resolution to reveal air holes and the density distribution inside the phantom. The system could possibly be applied to a packed bed column or a pipe flow in a petrochemical plant

  10. LSDCat: Detection and cataloguing of emission-line sources in integral-field spectroscopy datacubes

    Science.gov (United States)

    Herenz, Edmund Christian; Wisotzki, Lutz

    2017-06-01

    We present a robust, efficient, and user-friendly algorithm for detecting faint emission-line sources in large integral-field spectroscopic datacubes together with the public release of the software package Line Source Detection and Cataloguing (LSDCat). LSDCat uses a three-dimensional matched filter approach, combined with thresholding in signal-to-noise, to build a catalogue of individual line detections. In a second pass, the detected lines are grouped into distinct objects, and positions, spatial extents, and fluxes of the detected lines are determined. LSDCat requires only a small number of input parameters, and we provide guidelines for choosing appropriate values. The software is coded in Python and capable of processing very large datacubes in a short time. We verify the implementation with a source insertion and recovery experiment utilising a real datacube taken with the MUSE instrument at the ESO Very Large Telescope. The LSDCat software is available for download at http://muse-vlt.eu/science/tools and via the Astrophysics Source Code Library at http://ascl.net/1612.002

  11. Mantle cloaks for elliptical cylinders excited by an electric line source

    DEFF Research Database (Denmark)

    Kaminski, Piotr Marek; Yakovlev, Alexander B.; Arslanagic, Samel

    2016-01-01

    We investigate the ability of surface impedance mantle cloaks for cloaking of elliptical cylinders excited by an electric line source. The exact analytical solution of the problem utilizing Mathieu functions is obtained and is used to derive optimal surface impedances to cloak a number of configu......We investigate the ability of surface impedance mantle cloaks for cloaking of elliptical cylinders excited by an electric line source. The exact analytical solution of the problem utilizing Mathieu functions is obtained and is used to derive optimal surface impedances to cloak a number...

  12. Can you build an iPhone app without writing a single line of code?

    Science.gov (United States)

    Ramachandran, R.; Maskey, M.

    2011-12-01

    At the last ESIP summer meeting, a study was conducted to explore different commercial tools now available that allow one to create a mobile app without writing a single line of code. The proposed research comprised of two components. First, systematically evaluate different tools to create mobile apps along the dimensions of features and price. Second, create an iPhone app prototype for the ESIP community using some of these tools. The initial assessment classified the currently available tools to create mobile app tools into two categories. The tools that fall under the first category require no programming, but the content for the mobile apps are fed to it either via a web site RSS feed or entered manually. Consequently, these tools only support limited user interactivity. These tools follow the business model of website hosting services. This business model offers a set of templates to the end users with limited customization features to create their content in order to publish to websites. The second category of tools requires programming, but the code can be written in popular languages such as Javascript (compatible with most mobile platforms) rather than mobile app specific languages. For the second component of the study, two ESIP iPhone app prototypes were created. The first prototype required no programming and used the AppMakr tool. Objective C was used to create the second iPhone prototype from scratch and the source code for this prototype is available on the ESIP website. The study concluded that existing tools do make it easy to create a simple mobile app especially if one already has a well designed website. The associated costs are adequate but not cheap. However, if the mobile app has requirements that require interactivity and specialized customization then one needs to work with a mobile app developer.

  13. Linewidth statistics of single InGaAs quantum dot photolumincescence lines

    DEFF Research Database (Denmark)

    Leosson, Kristjan; Jensen, Jacob Riis; Hvam, Jørn Märcher

    2000-01-01

    We have used photoluminescence spectroscopy with high spatial and spectral resolution to measure the linewidths of single emission lines from In0.5Ga0.5As/GaAs self-assembled quantum dots. At 10 K, we find a broad, asymmetric distribution of linewidths with a maximum at 50 mu eV. The distribution......-dot luminescence lines depends only weakly on temperature up to 50 K, showing a broadening of 0.4 mu eV/K. Above 50 K, a thermally activated behavior of the linewidth is observed. This temperature dependence is consistent with the discrete energy level structure of the dots....

  14. Status and Needs Research for On-line Monitoring of VOCs Emissions from Stationary Sources

    Science.gov (United States)

    Zhou, Gang; Wang, Qiang; Zhong, Qi; Zhao, Jinbao; Yang, Kai

    2018-01-01

    Based on atmospheric volatile organic compounds (VOCs) pollution control requirements during the twelfth-five year plan and the current status of monitoring and management at home and abroad, instrumental architecture and technical characteristics of continuous emission monitoring systems (CEMS) for VOCs emission from stationary sources are investigated and researched. Technological development needs of VOCs emission on-line monitoring techniques for stationary sources in china are proposed from the system sampling pretreatment technology and analytical measurement techniques.

  15. Investigation on a Novel Discontinuous Pulse-Width Modulation Algorithm for Single-phase Voltage Source Rectifier

    DEFF Research Database (Denmark)

    Qu, Hao; Yang, Xijun; Guo, Yougui

    2014-01-01

    Single-phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). Single-phase VSC...

  16. Targeted genetics in Drosophila cell lines: Inserting single transgenes in vitro.

    Science.gov (United States)

    Manivannan, Sathiya N; Simcox, Amanda

    2016-07-02

    A long-standing problem with analyzing transgene expression in tissue-culture cells is the variation caused by random integration of different copy numbers of transfected transgenes. In mammalian cells, single transgenes can be inserted by homologous recombination but this process is inefficient in Drosophila cells. To tackle this problem, our group, and the Cherbas group, used recombination-mediated cassette exchange (RMCE) to introduce single-copy transgenes into specific locations in the Drosophila genome. In both cases, ϕC31 was used to catalyze recombination between its target sequences attP in the genome, and attB flanking the donor sequence. We generated cell lines de novo with a single attP-flanked cassette for recombination, whereas, Cherbas et al. introduced a single attP-flanked cassette into existing cell lines. In both approaches, a 2-drug selection scheme was used to select for cells with a single copy of the donor sequence inserted by RMCE and against cells with random integration of multiple copies. Here we describe the general advantages of using RMCE to introduce genes into fly cells, the different attributes of the 2 methods, and how future work could make use of other recombinases and CRISPR/Cas9 genome editing to further enable genetic manipulation of Drosophila cells in vitro.

  17. Strong field line shapes and photon statistics from a single molecule under anomalous noise.

    Science.gov (United States)

    Sanda, Frantisek

    2009-10-01

    We revisit the line-shape theory of a single molecule with anomalous stochastic spectral diffusion. Waiting time profiles for bath induced spectral jumps in the ground and excited states become different when a molecule, probed by continuous-wave laser field, reaches the steady state. This effect is studied for the stationary dichotomic continuous-time-random-walk spectral diffusion of a single two-level chromophore with power-law distributions of waiting times. Correlated waiting time distributions, line shapes, two-point fluorescence correlation function, and Mandel Q parameter are calculated for arbitrary magnitude of laser field. We extended previous weak field results and examined the breakdown of the central limit theorem in photon statistics, indicated by asymptotic power-law growth of Mandel Q parameter. Frequency profile of the Mandel Q parameter identifies the peaks of spectrum, which are related to anomalous spectral diffusion dynamics.

  18. Dynamically unpolarized single-photon source in diamond with intrinsic randomness

    OpenAIRE

    Abe, Naofumi; Mitsumori, Yasuyoshi; Sadgrove, Mark; Edamatsu, Keiichi

    2017-01-01

    Polarization is one of the fundamental properties of light, providing numerous applications in science and technology. While ?dynamically unpolarized? single-photon sources are demanded for various quantum applications, such sources have never been explored. Here we demonstrate dynamically unpolarized single-photon emission from a single [111]-oriented nitrogen- vacancy centre in diamond, in which the single-photon stream is unpolarized, exhibiting intrinsic randomness with vanishing polariza...

  19. evaluation of bamboo porous pipe as line source emitter in trickle ...

    African Journals Online (AJOL)

    CHRISTY

    This paper attempts to evaluate the use of bamboo as porous pipe (line source) emitter in trickle ... KEY WORDS: Trickle irrigation, Bamboo, emitter, Porous-pipe. INTRODUCTION. Trickle irrigation system also known as drip irrigation is one of the examples of localized ... period of time to maintain part of the soil at or.

  20. Evaluation of Bamboo Porous Pipe as Line Source Emitter in Trickle ...

    African Journals Online (AJOL)

    This paper attempts to evaluate the use of bamboo as porous pipe (line source) emitter in trickle irrigation at the Cross River University of Technology Teaching and Research Farm Obubra. Two sets of bamboo laterals: opened and plugged ends were used for the trial. The experiment was conducted using four different ...

  1. Meta-heuristic and Constraint-Based Approaches for Single-Line Railway Timetabling

    Science.gov (United States)

    Barber, Federico; Ingolotti, Laura; Lova, Antonio; Tormos, Pilar; Salido, Miguel A.

    This chapter is devoted to recent advances in heuristic and metaheuristic procedures, arising from the areas of Computer Science and Artificial Intelligence, which are able to cope with large scale problems as those in single-line railway timetable optimization. Timetable design is a central problem in railway planning. In the basic timetabling problem, we are given a line plan as well as demand and infrastructure information. The goal is to compute timetables for passengers and cargo trains that satisfy infrastructure capacity and achieve multicriteria objectives: minimal passenger waiting time (both at changeovers and onboard), efficient use of trains, etc. Due to its central role in the planning process of railway scheduling, timetable design has many interfaces with other classical problems: line planning, vehicle scheduling, and delay management.

  2. Arterial hypertension: second-line treatment. Try other single-agent treatments.

    Science.gov (United States)

    2008-06-01

    (1) Reliable evidence supports the use of thiazide diuretics (chlortalidone or hydrochlorothiazide) as first-line treatment for uncomplicated arterial hypertension. (2) When patients fail to reach blood pressure targets with well-conducted treatment with thiazide diuretics, or this treatment is poorly tolerated, what are the best second-line options? To answer this question, we reviewed the available evidence, based on our standard in-house methodology. (3) We found no published trials specifically designed to evaluate second-line antihypertensive treatments in cardiovascular prevention. There were no available trials of dual- versus single-agent therapy after failure of a thiazide diuretic. (4) When the blood pressure target is not reached, inadequate drug efficacy is only one of several possible causes. Various other factors affecting blood pressure should also be investigated. (5) Dual-agent therapy carries an increased risk of adverse effects and drug interactions compared to monotherapy. (6) There is no consensus among clinical practice guidelines on second-line antihypertensive therapy. However, to minimise the risk of adverse effects, it is clearly better to select single-agent therapy with a drug that has been shown to prevent cardiovascular events in first-line treatment of otherwise healthy hypertensive patients. Possible options include: angiotensin-converting-enzyme inhibitors, angiotensin II antagonists, calcium channel blockers or betablockers. In patients over the age of 60, betablockers seem less effective that the other drugs in preventing strokes. (7) There is too little evidence to choose a specific third-line combination rather than another. However, any adverse effects that the patient experienced during prior treatments should be taken into account.

  3. The origin of the optical emission lines associated with extragalactic radio sources

    Science.gov (United States)

    Viegas, S. M.; De Gouveia Dal Pino, E. M.

    1992-01-01

    The observed extended emission line regions (EELRs) associated with radio sources are investigated with the objective of determining the characteristics of the ionization mechanisms and the possible effect of star formation. The sources included in the sample are 3C 227, 3C 277.3, 3C 305, Cen A (NGC 5128), NGC 7385, PKS 0349-27, PKS 2152-69, and Minkowski's Object. It is shown that the emission-line ratios of the EELRs considered can be explained by models which account for the coupled effect of photoionization and shock acting at different degrees. It is also shown that the EELR ionization is not due to young stars. The main energy sources of the EELR are identified.

  4. Radiation source states on-line supervision system design and implementation based on RFID technology

    International Nuclear Information System (INIS)

    Yang Binhua; Ling Qiu; Yin Guoli; Yang Kun; Wan Xueping; Wang Kan

    2011-01-01

    It puts forward radiation source states on-line monitoring resolution based on RFID technology. Firstly, the system uses RFID in real-time transmission of the radiation dose rate, and monitors the radiation source states and dose rate of the surrounding environment on-line. Then it adopts regional wireless networking mode to construct enterprise level monitoring network, which resolves long-distance wiring problems. And then it uses GPRS wireless to transport the real-time data to the monitoring center and the government supervision department, By adopting randomly dynamic cording in display update every day, it strengthens the supervision of the radiation source. At last this system has been successful applied to a thickness gauge project, which verifies the feasibility and practicality is good. (authors)

  5. Dynamically reconfigurable directionality of plasmon-based single photon sources

    DEFF Research Database (Denmark)

    Chen, Yuntian; Lodahl, Peter; Koenderink, A. Femius

    2010-01-01

    We propose a plasmon-based reconfigurable antenna to controllably distribute emission from single quantum emitters in spatially separated channels. Our calculations show that crossed particle arrays can split the stream of photons from a single emitter into multiple narrow beams. We predict...... that beams can be switched on and off by switching host refractive index. The design method is based on engineering the dispersion relations of plasmon chains and is generally applicable to traveling wave antennas. Controllable photon delivery has potential applications in classical and quantum communication....

  6. Photonic wires and trumpets for ultrabright single photon sources

    DEFF Research Database (Denmark)

    Gérard, Jean-Michel; Claudon, Julien; Bleuse, Joël

    2013-01-01

    as to tailor their radiation diagram in the far-field. We highlight the novel “photonic trumpet” geometry, which provides a clean Gaussian beam, and is much less sensitive to fabrication imperfections than the more common needle-like taper geometry. S4Ps based on a single QD in a PW with integrated bottom...

  7. A new source of radiation in single-bubble sonoluminescence

    Indian Academy of Sciences (India)

    2017-03-28

    Mar 28, 2017 ... In this article, by considering single-bubble sonoluminescence and based on the hydrochemical model and thermal bremsstrahlung approach, for the first time two different origins of light have numerically been studied to describe the Ar bubble radiation in water at the moment of collapse: (a) radiation.

  8. A new source of radiation in single-bubble sonoluminescence

    Indian Academy of Sciences (India)

    ://www.ias.ac.in/article/fulltext/pram/088/04/0072 ... In this article, by considering single-bubble sonoluminescence and based on the hydrochemical model and thermal bremsstrahlung approach, for the first time two different origins of light ...

  9. Open Source Clinical NLP – More than Any Single System

    Science.gov (United States)

    Masanz, James; Pakhomov, Serguei V.; Xu, Hua; Wu, Stephen T.; Chute, Christopher G.; Liu, Hongfang

    2014-01-01

    The number of Natural Language Processing (NLP) tools and systems for processing clinical free-text has grown as interest and processing capability have surged. Unfortunately any two systems typically cannot simply interoperate, even when both are built upon a framework designed to facilitate the creation of pluggable components. We present two ongoing activities promoting open source clinical NLP. The Open Health Natural Language Processing (OHNLP) Consortium was originally founded to foster a collaborative community around clinical NLP, releasing UIMA-based open source software. OHNLP’s mission currently includes maintaining a catalog of clinical NLP software and providing interfaces to simplify the interaction of NLP systems. Meanwhile, Apache cTAKES aims to integrate best-of-breed annotators, providing a world-class NLP system for accessing clinical information within free-text. These two activities are complementary. OHNLP promotes open source clinical NLP activities in the research community and Apache cTAKES bridges research to the health information technology (HIT) practice. PMID:25954581

  10. Open Source Clinical NLP - More than Any Single System.

    Science.gov (United States)

    Masanz, James; Pakhomov, Serguei V; Xu, Hua; Wu, Stephen T; Chute, Christopher G; Liu, Hongfang

    2014-01-01

    The number of Natural Language Processing (NLP) tools and systems for processing clinical free-text has grown as interest and processing capability have surged. Unfortunately any two systems typically cannot simply interoperate, even when both are built upon a framework designed to facilitate the creation of pluggable components. We present two ongoing activities promoting open source clinical NLP. The Open Health Natural Language Processing (OHNLP) Consortium was originally founded to foster a collaborative community around clinical NLP, releasing UIMA-based open source software. OHNLP's mission currently includes maintaining a catalog of clinical NLP software and providing interfaces to simplify the interaction of NLP systems. Meanwhile, Apache cTAKES aims to integrate best-of-breed annotators, providing a world-class NLP system for accessing clinical information within free-text. These two activities are complementary. OHNLP promotes open source clinical NLP activities in the research community and Apache cTAKES bridges research to the health information technology (HIT) practice.

  11. Conservative site-specific and single-copy transgenesis in human LINE-1 elements.

    Science.gov (United States)

    Vijaya Chandra, Shree Harsha; Makhija, Harshyaa; Peter, Sabrina; Myint Wai, Cho Mar; Li, Jinming; Zhu, Jindong; Ren, Zhonglu; D'Alcontres, Martina Stagno; Siau, Jia Wei; Chee, Sharon; Ghadessy, Farid John; Dröge, Peter

    2016-04-07

    Genome engineering of human cells plays an important role in biotechnology and molecular medicine. In particular, insertions of functional multi-transgene cassettes into suitable endogenous sequences will lead to novel applications. Although several tools have been exploited in this context, safety issues such as cytotoxicity, insertional mutagenesis and off-target cleavage together with limitations in cargo size/expression often compromise utility. Phage λ integrase (Int) is a transgenesis tool that mediates conservative site-specific integration of 48 kb DNA into a safe harbor site of the bacterial genome. Here, we show that an Int variant precisely recombines large episomes into a sequence, term edattH4X, found in 1000 human Long INterspersed Elements-1 (LINE-1). We demonstrate single-copy transgenesis through attH4X-targeting in various cell lines including hESCs, with the flexibility of selecting clones according to transgene performance and downstream applications. This is exemplified with pluripotency reporter cassettes and constitutively expressed payloads that remain functional in LINE1-targeted hESCs and differentiated progenies. Furthermore, LINE-1 targeting does not induce DNA damage-response or chromosomal aberrations, and neither global nor localized endogenous gene expression is substantially affected. Hence, this simple transgene addition tool should become particularly useful for applications that require engineering of the human genome with multi-transgenes. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.

  12. Field Geometric Calibration Method for Line Structured Light Sensor Using Single Circular Target

    Directory of Open Access Journals (Sweden)

    Tianfei Chen

    2017-01-01

    Full Text Available To achieve fast calibration of line structured light sensor, a geometric calibration approach based on single circular calibration target is proposed. The proposed method uses the circular points to establish linear equations, and according to the angle constraint, the camera intrinsic parameters can be calculated through optimization. Then, the light plane calibration is accomplished in two steps. Firstly, when the vanishing lines of target plane at various postures are obtained, the intersections between vanishing lines and laser stripe can be computed, and the normal vector of light plane can be calibrated via line fitting method using intersection points. After that, the distance from the origin of camera coordinate system to the light plane can be derived based on the model of perspective-three-point. The actual experimental result shows that this calibration method has high accuracy, its average measuring accuracy is 0.0451 mm, and relative error is 0.2314%. In addition, the entire calibration process has no complex operations. It is simple, convenient, and suitable for calibration on sites.

  13. Single-shot in-line digital holography without twin image

    Science.gov (United States)

    Nomura, Takanori

    2018-01-01

    In-line digital holography is conventional but still attractive because of its simple optical setup. In general, sequential phase-shifting technique is mandatory to remove twin-image which makes the reconstructed image quality low. However, sequential phase-shifting technique requires multiple recording. Multiple recording means that it is not suitable for a dynamic phenomenon. In this paper, two kinds of a single-shot in-line digital holography without twin-image using a diffused illumination are presented. One is a generalized phase-shifting digital holography and the other is a computational removal of twin-image. The ideas and their experimental results are given to confirm the feasibility.

  14. Non-Linear Transmission Line (NLTL) Microwave Source Lecture Notes the United States Particle Accelerator School

    Energy Technology Data Exchange (ETDEWEB)

    Russell, Steven J. [Los Alamos National Laboratory; Carlsten, Bruce E. [Los Alamos National Laboratory

    2012-06-26

    We will quickly go through the history of the non-linear transmission lines (NLTLs). We will describe how they work, how they are modeled and how they are designed. Note that the field of high power, NLTL microwave sources is still under development, so this is just a snap shot of their current state. Topics discussed are: (1) Introduction to solitons and the KdV equation; (2) The lumped element non-linear transmission line; (3) Solution of the KdV equation; (4) Non-linear transmission lines at microwave frequencies; (5) Numerical methods for NLTL analysis; (6) Unipolar versus bipolar input; (7) High power NLTL pioneers; (8) Resistive versus reactive load; (9) Non-lineaer dielectrics; and (10) Effect of losses.

  15. Electron-density-sensitive Line Ratios of Fe XIII– XVI from Laboratory Sources Compared to CHIANTI

    Science.gov (United States)

    Weller, M. E.; Beiersdorfer, P.; Soukhanovskii, V. A.; Scotti, F.; LeBlanc, B. P.

    2018-02-01

    We present electron-density-sensitive line ratios for Fe XIII– XVI measured in the spectral wavelength range of 200–440 Å and an electron density range of (1–4) × 1013 cm‑3. The results provide a test at the high-density limit of density-sensitive line ratios useful for astrophysical studies. The measurements were performed on the National Spherical Torus Experiment-Upgrade, where electron densities were measured independently by the laser Thomson scattering diagnostic. Spectra were collected with a flat-field grazing-incidence spectrometer, which provided a spectral resolution of up to 0.3 Å, i.e., high resolution across the broad wavelength range. The response of the instrument was relatively calibrated using spectroscopic techniques in order to improve accuracy. The line ratios are compared to other laboratory sources and the latest version of CHIANTI (8.0.2), and an agreement within 30% is found.

  16. Multi-source remote-sensing image matching based on epipolar line and least squares

    Science.gov (United States)

    Chen, Peng; Mao, Zhihua; Chen, Jianyu; Zhang, Xiaoping; Li, Zifeng

    2013-10-01

    In remote sensing image applications, the image matching is a very key technology, its quality directly related to the quality of the subsequent results. This paper studied an improved SIFT features matching method for muili-source remote-sensing image registration based on GPU computing, epipolar line and least squares, its main purpose is to take both accuracy and efficiency into consideration. This method is firstly based on tonal balanced methods matching, and then exracts SIFT features based on the GPU computing technology, and then matchs feature points based on epipolar line and least squares matching method with RANSAC method, finally analies error sources of SIFT mismatch, researchs an improved SIFT mismatch reduce strategy.The experimental results prove that the method can effectively improve the efficiency and precision of SIFT feature matching.

  17. National Synchrotron Light Source users manual: Guide to the VUV and x-ray beam lines

    International Nuclear Information System (INIS)

    Gmuer, N.F.; White-DePace, S.M.

    1987-08-01

    The success of the National Synchrotron Light Source in the years to come will be based, in large part, on the size of the users community and the diversity of the scientific disciplines represented by these users. In order to promote this philosophy, this National Synchrotron Light Source (NSLS) Users Manual: Guide to the VUV and X-Ray Beam Lines, has been published. This manual serves a number of purposes. In an effort to attract new research, it will present to the scientific community-at-large the current and projected architecture and capabilities of the various VUV and x-ray beam lines and storage rings. We anticipate that this publication will be updated periodically in order to keep pace with the constant changes at the NSLS

  18. Single Source Determination for Coors/TriGen

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  19. Northeast Hub Partners and United Salts Single Source Determination

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  20. Charge transport across a single-Cooper-pair transistor coupled to a resonant transmission line

    Energy Technology Data Exchange (ETDEWEB)

    Leppaekangas, Juha [Institut fuer Theoretische Festkoerperphysik, Karlsruhe Institute of Technology, D-76128 Karlsruhe (Germany); Department of Physical Sciences, University of Oulu, FI-90014 Oulu (Finland); Pashkin, Yuri [NEC Nano Electronics Research Laboratories, RIKEN Advanced Science Institute, Tsukuba, Ibaraki 305-8501 (Japan); Thuneberg, Erkki [Department of Physical Sciences, University of Oulu, FI-90014 Oulu (Finland)

    2010-07-01

    We have investigated charge transport in ultrasmall superconducting single and double Josephson junctions coupled to a transmission-line resonator. The microstrip resonator is naturally formed by the on-chip leads and the sample holder. We observe equidistant peaks in the transport characteristics of both types of devices and attribute them to the process involving simultaneous tunneling of Cooper pairs and photon emission into the resonator. The experimental data is well reproduced with the orthodox model of Cooper pair tunneling that accounts for the microwave photon emission into the resonator.

  1. Resolution enhancement method for lensless in-line holographic microscope with spatially-extended light source.

    Science.gov (United States)

    Feng, Shaodong; Wu, Jigang

    2017-10-02

    We propose a resolution enhancement method for lensless in-line holographic microscope (LIHM) with spatially-extended light source, where the resolution is normally deteriorated by the insufficient spatial coherence of the illumination. In our LIHM setup, a light-emitting diode (LED), which was a spatially-extended light source, directly illuminated the sample, and the in-line hologram were recorded by a CMOS imaging sensor located behind the sample. In our holographic reconstruction process, the in-line hologram was first deconvoled with a properly resized image of the LED illumination area, and then back-propagated with scalar diffraction formula to reconstruct the sample image. We studied the hologram forming process and showed that the additional deconvolution process besides normal scalar diffraction reconstruction in LIHM can effectively enhance the imaging resolution. The resolution enhancements capability was calibrated by numerical simulations and imaging experiments with the U.S. air force target as the sample. We also used our LIHM to image the wing of a green lacewing to further demonstrate the capability of our methods for practical imaging applications. Our methods provide a way for LIHM to achieve satisfactory resolution with less stringent requirement for spatial coherence of the source and could reduce the cost for compact imaging system.

  2. Plane-based optimization for 3D object reconstruction from single line drawings.

    Science.gov (United States)

    Liu, Jianzhuang; Cao, Liangliang; Li, Zhenguo; Tang, Xiaoou

    2008-02-01

    In previous optimization-based methods of 3D planar-faced object reconstruction from single 2D line drawings, the missing depths of the vertices of a line drawing (and other parameters in some methods) are used as the variables of the objective functions. A 3D object with planar faces is derived by finding values for these variables that minimize the objective functions. These methods work well for simple objects with a small number N of variables. As N grows, however, it is very difficult for them to find expected objects. This is because with the nonlinear objective functions in a space of large dimension N, the search for optimal solutions can easily get trapped into local minima. In this paper, we use the parameters of the planes that pass through the planar faces of an object as the variables of the objective function. This leads to a set of linear constraints on the planes of the object, resulting in a much lower dimensional nullspace where optimization is easier to achieve. We prove that the dimension of this nullspace is exactly equal to the minimum number of vertex depths which define the 3D object. Since a practical line drawing is usually not an exact projection of a 3D object, we expand the nullspace to a larger space based on the singular value decomposition of the projection matrix of the line drawing. In this space, robust 3D reconstruction can be achieved. Compared with two most related methods, our method not only can reconstruct more complex 3D objects from 2D line drawings, but also is computationally more efficient.

  3. Technology development for a single-photon source

    International Nuclear Information System (INIS)

    Enzmann, Roland

    2011-01-01

    The growth of InAs-quantum dots on GaAs-substrate is established concerning low quantum dot densities (ca. 1 pro μm 2 ) and high densities (> 100 pro μm 2 ). However it is not possible to reach the telecommunication wavelength regime around 1.55 μm with InAs-quantum dots on GaAs-substrate. In contrast to this, InP based materials, in general, provide the emission wavelength of 1.55 μm. But the effort to fabricate InAs nanostructures on InP based material system by molecular beam epitaxy does not lead to quantum dots but in general to quantum dashes, which arise in high surface densities. To enable the growth of InAs-quantum dots based on InP several detailed growth studies on to InP-substrate lattice matched matrix material Al x Ga y In 1-x-y As were performed. Thereby the influence of growth rate, growth temperature, InAs coverage and the indium content on the growth surface have been investigated. InAs has been deposited on a thin indiumfree ''sublayer''. The corresponding growth studies showed that a 0.6 nm thick GaSb sublayer is the best choice. Using this technique quantum dots with surface densities from 1 to 150 per μm 2 could be realized. To make low quantum dot densities also on layers containing much aluminium possible, the Al x Ga y In 1-x-y As alloy was grown in the digital alloy growth mode, that is to say the pseudo binaries Al 0,48 In 0,52 As and Ga 0,47 In 0,53 As are grown by the second. By varying the bandgap of the matrix material, viz. by varying the aluminum content, single quantum dots emitting in the range from 1100 nm to 1560 nm could be realized. This way as well the optical O-band (1.3 μm) with an aluminum content of 13% as the optical C-band (1.55 μm) with an aluminum content of 4% could be realized. Another possibility to tailor the emission wavelength of quantum dots are so called stacked dots. In the process two layer of quantum dots, separated with a thin spacer layer, were deposited upon each other. By this way a redshift of

  4. Running the number line: Rapid shifts of attention in single-digit arithmetic.

    Science.gov (United States)

    Mathieu, Romain; Gourjon, Audrey; Couderc, Auriane; Thevenot, Catherine; Prado, Jérôme

    2016-01-01

    It has been recently proposed that adults might solve single-digit addition and subtraction problems by rapidly moving through an ordered representation of numbers. In the present study, we tested whether these movements manifest themselves by on-line shifts of attention during arithmetic problem-solving. In two experiments, adult participants were presented with single-digit addition, subtraction and multiplication problems. Operands and operator were presented sequentially on the screen. Although both the first operand and the operator were presented at the center of the screen, the second operand was presented either to the left or to the right side of space. We found that addition problems were solved faster when the second operand appeared to the right than to the left side (Experiments 1 & 2). In contrast, subtraction problems were solved faster when the second operand appeared to the left than to the right side (Experiment 1). No operation-dependent spatial bias was observed in the same time window when the second operand was zero (Experiment 1), and no bias was observed when the operation was a multiplication (Experiment 2). Therefore, our results demonstrate that solving single-digit addition and subtraction, but not multiplication, is associated with horizontal shifts of attention. Our findings support the idea that mental movements to the left or right of a sequential representation of numbers are elicited during single-digit arithmetic. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Excitation of Love waves in a thin film layer by a line source.

    Science.gov (United States)

    Tuan, H.-S.; Ponamgi, S. R.

    1972-01-01

    The excitation of a Love surface wave guided by a thin film layer deposited on a semiinfinite substrate is studied in this paper. Both the thin film and the substrate are considered to be elastically isotropic. Amplitudes of the surface wave in the thin film region and the substrate are found in terms of the strength of a line source vibrating in a direction transverse to the propagating wave. In addition to the surface wave, the bulk shear wave excited by the source is also studied. Analytical expressions for the bulk wave amplitude as a function of the direction of propagation, the acoustic powers transported by the surface and bulk waves, and the efficiency of surface wave excitation are obtained. A numerical example is given to show how the bulk wave radiation pattern depends upon the source frequency, the film thickness and other important parameters of the problem. The efficiency of surface wave excitation is also calculated for various parameter values.

  6. Radiosensitivity evaluation of Human tumor cell lines by single cell gel electrophoresis

    International Nuclear Information System (INIS)

    Zhang Yipei; Cao Jia; Wang Yan; Du Liqing; Li Jin; Wang Qin; Fan Feiyue; Liu Qiang

    2011-01-01

    Objective: To explore the feasibility of determining radiosensitivity of human tumor cell lines in vitro using single cell gel electrophoresis (SCGE). Methods: Three human tumor cell lines were selected in this study, HepG 2 , EC-9706 and MCF-7. The surviving fraction (SF) and DNA damage were detected by MTT assay, nested PCR technique and comet assay respectively. Results: MTT assay: The SF of HepG 2 and EC-9706 after irradiated by 2, 4 and 8 Gy was lower significantly than that of MCF-7, which showed that the radiosensitivity of HepG 2 and EC-9706 was higher than that of MCF-7. But there was no statistical difference of SF between HepG 2 and EC-9706. SCGE: The difference of radiosensitivity among these three tumor cell lines was significant after 8 Gy γ-ray irradiation. Conclusion: The multi-utilization of many biological parameter is hopeful to evaluate the radiosensitivity of tumor cells more objectively and exactly. (authors)

  7. A New Diagnostic Diagram of Ionization Sources for High-redshift Emission Line Galaxies

    Science.gov (United States)

    Zhang, Kai; Hao, Lei

    2018-04-01

    We propose a new diagram, the kinematics–excitation (KEx) diagram, which uses the [O III] λ5007/Hβ line ratio and the [O III] λ5007 emission line width (σ [O III]) to diagnose the ionization source and physical properties of active galactic nuclei (AGNs) and star-forming galaxies (SFGs). The KEx diagram is a suitable tool to classify emission line galaxies at intermediate redshift because it uses only the [O III] λ5007 and Hβ emission lines. We use the main galaxy sample of SDSS DR7 and the Baldwin‑Phillips‑Terlevich (BPT) diagnostic to calibrate the diagram at low redshift. The diagram can be divided into three regions: the KEx-AGN region, which consists mainly of pure AGNs, the KEx-composite region, which is dominated by composite galaxies, and the KEx-SFG region, which contains mostly SFGs. LINERs strongly overlap with the composite and AGN regions. AGNs are separated from SFGs in this diagram mainly because they preferentially reside in luminous and massive galaxies and have higher [O III]/Hβ than SFGs. The separation between AGNs and SFGs is even cleaner thanks to the additional 0.15/0.12 dex offset in σ [O III] at fixed luminosity/stellar mass. We apply the KEx diagram to 7866 galaxies at 0.3 tests support the reliability of this classification diagram for emission line galaxies at intermediate redshift. At z ∼ 2, the demarcation line between SFGs and AGNs is shifted by ∼0.3 dex toward higher values of σ [O III] due to evolution effects.

  8. STATCONT: A statistical continuum level determination method for line-rich sources

    Science.gov (United States)

    Sánchez-Monge, Á.; Schilke, P.; Ginsburg, A.; Cesaroni, R.; Schmiedeke, A.

    2018-01-01

    STATCONT is a python-based tool designed to determine the continuum emission level in spectral data, in particular for sources with a line-rich spectrum. The tool inspects the intensity distribution of a given spectrum and automatically determines the continuum level by using different statistical approaches. The different methods included in STATCONT are tested against synthetic data. We conclude that the sigma-clipping algorithm provides the most accurate continuum level determination, together with information on the uncertainty in its determination. This uncertainty can be used to correct the final continuum emission level, resulting in the here called `corrected sigma-clipping method' or c-SCM. The c-SCM has been tested against more than 750 different synthetic spectra reproducing typical conditions found towards astronomical sources. The continuum level is determined with a discrepancy of less than 1% in 50% of the cases, and less than 5% in 90% of the cases, provided at least 10% of the channels are line free. The main products of STATCONT are the continuum emission level, together with a conservative value of its uncertainty, and datacubes containing only spectral line emission, i.e., continuum-subtracted datacubes. STATCONT also includes the option to estimate the spectral index, when different files covering different frequency ranges are provided.

  9. Noise Sources, Effects and Countermeasures in Narrowband Power-Line Communications Networks: A Practical Approach

    Directory of Open Access Journals (Sweden)

    Gregorio López

    2017-08-01

    Full Text Available The integration of Distributed Generation, Electric Vehicles, and storage without compromising the quality of the power delivery requires the deployment of a communications overlay that allows monitoring and controlling low voltage networks in almost real time. Power Line Communications are gaining momentum for this purpose since they present a great trade-off between economic and technical features. However, the power lines also represent a harsh communications medium which presents different problems such as noise, which is indeed affected by Distributed Generation, Electric Vehicles, and storage. This paper provides a comprehensive overview of the types of noise that affects Narrowband Power Line Communications, including normative noises, noises coming from common electronic devices measured in actual operational power distribution networks, and noises coming from photovoltaic inverters and electric vehicle charging spots measured in a controlled environment. The paper also reviews several techniques to mitigate the effects of noise, paying special attention to passive filtering, as for being one of the most widely used solution to avoid this kind of problems in the field. In addition, the paper presents a set of tests carried out to evaluate the impact of some representative noises on Narrowband Power Line Communications network performance, as well as the effectiveness of different passive filter configurations to mitigate such an impact. In addition, the considered sources of noise can also bring value to further improve PLC communications in the new scenarios of the Smart Grid as an input to theoretical models or simulations.

  10. Multiple breast cancer cell-lines derived from a single tumor differ in their molecular characteristics and tumorigenic potential.

    Directory of Open Access Journals (Sweden)

    Goar Mosoyan

    Full Text Available BACKGROUND: Breast cancer cell lines are widely used tools to investigate breast cancer biology and to develop new therapies. Breast cancer tissue contains molecularly heterogeneous cell populations. Thus, it is important to understand which cell lines best represent the primary tumor and have similarly diverse phenotype. Here, we describe the development of five breast cancer cell lines from a single patient's breast cancer tissue. We characterize the molecular profiles, tumorigenicity and metastatic ability in vivo of all five cell lines and compare their responsiveness to 4-hydroxytamoxifen (4-OHT treatment. METHODS: Five breast cancer cell lines were derived from a single patient's primary breast cancer tissue. Expression of different antigens including HER2, estrogen receptor (ER, CK8/18, CD44 and CD24 was determined by flow cytometry, western blotting and immunohistochemistry (IHC. In addition, a Fluorescent In Situ Hybridization (FISH assay for HER2 gene amplification and p53 genotyping was performed on all cell lines. A xenograft model in nude mice was utilized to assess the tumorigenic and metastatic abilities of the breast cancer cells. RESULTS: We have isolated, cloned and established five new breast cancer cell lines with different tumorigenicity and metastatic abilities from a single primary breast cancer. Although all the cell lines expressed low levels of ER, their growth was estrogen-independent and all had high-levels of expression of mutated non-functional p53. The HER2 gene was rearranged in all cell lines. Low doses of 4-OHT induced proliferation of these breast cancer cell lines. CONCLUSIONS: All five breast cancer cell lines have different antigenic expression profiles, tumorigenicity and organ specific metastatic abilities although they derive from a single tumor. None of the studied markers correlated with tumorigenic potential. These new cell lines could serve as a model for detailed genomic and proteomic analyses to

  11. Synthesis of anisotropic CdS nanostructures via a single-source route

    CSIR Research Space (South Africa)

    Rajasekhar Pullabhotla, VSR

    2011-02-01

    Full Text Available A cadmium tetrahydroisoquinoline dithiocarbamate (DTC) complex has been used as single-source precursor for the synthesis of highly faceted hexadecylamine (HDA) capped CdS nanoparticles. Hexagonal and close to cubic shaped particles with distinct...

  12. Pulsed, Single-Frequency, 2-um Seed Source for Coherent LIDAR Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary objective of the proposed Phase I effort is to develop and demonstrate a low-average power, pulsed, single-frequency, 2-um Ho-laser source for...

  13. Room-Temperature Single-Photon Source for Secure Quantum Communication

    Data.gov (United States)

    National Aeronautics and Space Administration — We are asking for four years of support for PhD student Justin Winkler's work on a research project entitled "Room temperature single photon source for secure...

  14. Neutron beam line design of a white neutron source at CSNS

    Science.gov (United States)

    Jing, Hantao; Zhang, Liying; Tang, Jingyu; Ruan, Xichao; Ning, Changjun; Yu, Yongji; Wang, Pengcheng; Li, Qiang; Ren, Jie; Tang, Hongqing; Wang, Xiangqi

    2017-09-01

    China Spallation Neutron Source (CSNS), which is under construction, is a large scientific facility dedicated mainly for multi-disciplinary research on material characterization using neutron scattering techniques. The CSNS Phase-I accelerator will deliver a proton beam with an energy of 1.6 GeV and a pulse repetition rate of 25 Hz to a tungsten target, and the beam power is 100 kW. A white neutron source using the back-streaming neutrons through the incoming proton beam channel was proposed and is under construction. The back-streaming neutrons which are very intense and have good time structure are very suitable for nuclear data measurements. The white neutron source includes an 80-m neutron beam line, two experimental halls, and also six different types of spectrometers. The physics design of the beam line is presented in this paper, which includes beam optics and beam characterization simulations, with the emphasis on obtaining extremely low background. The first-batch experiments on nuclear data measurements are expected to be conducted in late 2017.

  15. The Advanced Light Source U8 beam line, 20--300 eV

    International Nuclear Information System (INIS)

    Heimann, P.; Warwick, T.; Howells, M.; McKinney, W.; Digennaro, D.; Gee, B.; Yee, D.; Kincaid, B.

    1991-10-01

    The U8 is a beam line under construction at the Advanced Light Source (ALS). The beam line will be described along with calculations of its performance and its current status. An 8 cm period undulator is followed by two spherical collecting mirrors, an entrance slit, spherical gratings having a 15 degree deviation angle, a moveable exit slit, and refocusing and branching mirrors. Internal water cooling is provided to the metal M1 and M2 mirrors as well as to the gratings. Calculations have been made of both the flux output and the resolution over its photon energy range of 20--300 eV. The design goal was to achieve high intensity, 10 12 photons/sec, at a high resolving power of 10,000. The U8 Participating Research Team (PRT) is planning experiments involving the photoelectron spectroscopy of gaseous atoms and molecules, the spectroscopy of ions and actinide spectroscopy

  16. Synchrotron X-Ray Microdiffraction Studies of Electromigration in Interconnect lines at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Nobumichi; Chen, Kai; Kunz, Martin

    2009-12-01

    Synchrotron polychromatic X-ray microdiffraction is a particularly suitable technique to study in situ the effect of electromigration in metal interconnects as add spatial resolution to grain orientation and strain sensitivity. This technique has been extensively used at the Advanced Light Source to monitor changes in aluminum and copper interconnect test structures while high-density current is passed into them during accelerated tests at elevated temperature. One of the principal findings is the observation of electromigration-induced plasticity in the metal lines that appear during the very early stages of electromigration. In some of the lines, high density of geometrically necessary dislocation are formed leading to additional diffusion paths causing an enhancement of electromigration effect at test temperature.

  17. Aerodynamic Mixing Downstream from Line Source of Heat in High-intensity Sound Field

    Science.gov (United States)

    Mickelson, William R; Baldwin, Lionel V

    1956-01-01

    Theory and measurement showed that the heat wake downstream from a line source is displaced by a transverse standing sound wave in a manner similar to a flag waving in a harmonic mode. With a 147 db, 104 cps standing wave, time-mean temperatures were reduced by an order of magnitude except near the displacement-pattern nodal points. The theory showed that a 161 db, 520 cps standing wave considerably increased the mixing in both the time-mean and instantaneous senses.

  18. Source term analysis for a criticality accident in metal production line glove boxes

    International Nuclear Information System (INIS)

    Nguyen, D.H.

    1991-06-01

    A recent development in criticality accident analysis is the deterministic calculations of the transport of fission products and actinides through the barriers of the physical facility. The knowledge of the redistribution of the materials inside the facility will help determine the reentry and clean-up procedures. The amount of radioactive materials released to the environment is the source term for dispersion calculations. We have used an integrated computer model to determine the release of fission products to the environment from a hypothetical criticality event in a glove box of the metal production line (MPL) at the Lawrence Livermore National Laboratory (LLNL)

  19. The Single Minute Exchange of Die Methodology in a High-Mix Processing Line

    Directory of Open Access Journals (Sweden)

    Filla Jan

    2016-06-01

    Full Text Available Because of turbulence in the economic environment, enterprises must react flexibly to the changing demands of their customers. Thus, a changeover process is required. If an enterprise has a large product portfolio, there are basically only two process options; to integrate production into large batches or to change the production programme frequently. Frequent changes associated with the changeover process of machinery are optimized by using the SMED method. The main goal of this paper is to apply SMED (Single Minute Exchange of Die to a High-Mix processing line. The case study is undertaken in a flat glass processing company which manufactures hundreds of types of products. The results of the case study demonstrate that it is possible to save up to 30% annually of the time currently spent on changeovers.

  20. Control of single-phase islanded PV/battery minigrids based on power-line signaling

    DEFF Research Database (Denmark)

    Quintana, Pablo; Guerrero, Josep M.; Dragicevic, Tomislav

    2014-01-01

    Power regulation of all converter units in a micro-grid should not be only determined by load demand, but also by the available power of each unit, i.e. a converter fed by a battery. Energy management control is essential in order to handle the variety of prime movers which may include different...... should be utilized as efficiently as possible. This paper proposes a coordinated control strategy based on power-line signaling (PLS), instead of common communications, for a single-phase minigrid in which each unit can operate in different operation modes taking into account the resource limitation....... The whole system is explained ahead and finally, Hardware in the loop results obtained with a dSPACE are presented in order to validate the proposed control strategy....

  1. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    CMS Collaboration

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hard sensors. Inside CMS two rings instrumented with 12 single crystal diamond sensors each are installed on both sides of the interaction point. The sensors are subdivided in two pads, and each pad is read out by a dedicated fast radiation hard ASIC in 130 nm CMOS technology. Due to the excellent time resolution collision products will be separated from machine induced background. In the backend a dead-time less histogramming unit is used, and a fast microTCA system with GHz sampling rate is under development. The detector will measure both the on-line luminosity and the background bunch-by-bunch. The performance of a prototype detector in a test-beam will be reported, and results from the operation during data taking will be presented.

  2. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    Karacheban, Olena

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hardsensors. Inside CMS two rings instrumented with 12 single crystal diamondsensors each are installed on both sides of the interaction point. Thesensors are subdivided in two pads, and each pad is read out by adedicated fast radiation hard ASIC in 130 nm CMOS technology.Due to the excellent time resolution collision products will be separatedfrom machine induced background. In the backend a dead-time lesshistogramming unit is udsed, and a fast microTCA system with GHz samplingrate is under development.The detector will measure both the on-line luminosity and the backgroundbunch-by-bunch.The performance of a prototype detector in a test-beam will be reported,and results from the operation during data taking will be presented.

  3. pH sensing through a single optical fibre using SERS and CMOS SPAD line arrays.

    Science.gov (United States)

    Ehrlich, K; Kufcsák, A; McAughtrie, S; Fleming, H; Krstajic, N; Campbell, C J; Henderson, R K; Dhaliwal, K; Thomson, R R; Tanner, M G

    2017-12-11

    Full exploitation of fibre Raman probes has been limited by the obstruction of weak Raman signals by background fluorescence of the sample and the intrinsic Raman signal of the delivery fibre. Here we utilised functionalised gold nanoshells (NS) to take advantage of the surface-enhanced Raman spectroscopy (SERS) effect to enhance the pH responsive spectrum of 4-mercaptobenzoic acid (MBA). However, the fibre background is still dominant. Using the photon arrival time-resolving capability of a CMOS single-photon avalanche diode (SPAD) based line sensor, we recover the SERS spectrum without a fibre background in a 10 s measurement. In this manner, pH sensing through a multimode fibre at a low excitation power that is safe for future in vivo applications, with short acquisition times (10 or 60 s), is demonstrated. A measurement precision of ± 0.07 pH units is thus achieved.

  4. Development of uniform hazard response spectra for rock sites considering line and point sources of earthquakes

    International Nuclear Information System (INIS)

    Ghosh, A.K.; Kushwaha, H.S.

    2001-12-01

    Traditionally, the seismic design basis ground motion has been specified by normalised response spectral shapes and peak ground acceleration (PGA). The mean recurrence interval (MRI) used to computed for PGA only. It is shown that the MRI associated with such response spectra are not the same at all frequencies. The present work develops uniform hazard response spectra i.e. spectra having the same MRI at all frequencies for line and point sources of earthquakes by using a large number of strong motion accelerograms recorded on rock sites. Sensitivity of the number of the results to the changes in various parameters has also been presented. This work is an extension of an earlier work for aerial sources of earthquakes. These results will help to determine the seismic hazard at a given site and the associated uncertainities. (author)

  5. A research on the positioning technology of vehicle navigation system from single source to "ASPN"

    Science.gov (United States)

    Zhang, Jing; Li, Haizhou; Chen, Yu; Chen, Hongyue; Sun, Qian

    2017-10-01

    Due to the suddenness and complexity of modern warfare, land-based weapon systems need to have precision strike capability on roads and railways. The vehicle navigation system is one of the most important equipments for the land-based weapon systems that have precision strick capability. There are inherent shortcomings for single source navigation systems to provide continuous and stable navigation information. To overcome the shortcomings, the multi-source positioning technology is developed. The All Source Positioning and Navigaiton (ASPN) program was proposed in 2010, which seeks to enable low cost, robust, and seamless navigation solutions for military to use on any operational platform and in any environment with or without GPS. The development trend of vehicle positioning technology was reviewed in this paper. The trend indicates that the positioning technology is developed from single source and multi-source to ASPN. The data fusion techniques based on multi-source and ASPN was analyzed in detail.

  6. Commissioning and Operation of the FNAL Front end Injection Line and Ion Sources.

    Energy Technology Data Exchange (ETDEWEB)

    Karns, Patrick R. [Indiana Univ., Bloomington, IN (United States)

    2015-09-01

    This thesis documents the efforts made in commissioning and operating the RFQ Injection Line (RIL) as a replacement for the Cockcroft Walton front end. The Low Energy Beam Transport (LEBT) was assembled and tested with multiwire position and emittance monitor measurements. The Radio Frequency Quadrupole (RFQ) commissioning was completed with the same measurements as well as output beam energy measurements that showed it initially accelerated beam only to 700 keV, which was 50 keV lower than the design energy. Working with the manufacturer solutions were found and instituted to continue testing. The Medium Energy Beam Transport (MEBT) was then connected as the RIL was installed as the new front end of Linac. Testing gave way to operation when the new front end was used as the source of all High Energy Physics (HEP) beam for Fermi National Accelerator Laboratory (FNAL). The magnetron ion source that provides the H- beam for the front end required several changes and eventual upgrades to operate well; such as new source operating points for vacuum pressure and cesium admixture, and new materials for critical source components. Further research was conducted on the cathode geometry and nitrogen doping of the hydrogen gas as well as using solid state switches for the extractor system high voltage.

  7. Measured, calculated and predicted Stark widths of the singly ionized C, N, O, F, Ne, Si, P, S, Cl and Ar spectral lines

    Directory of Open Access Journals (Sweden)

    Djeniže S.

    2000-01-01

    Full Text Available In order to find reliable Stark width data, needed in plasma spectroscopy comparision between the existing measured, calculated and predicted Stark width values was performed for ten singly ionized emitters: C, N, O, F, Ne Si, P, S, Cl and Ar in the lower lying 3s - 3p, 3p - 3d and 4s - 4p transitions. These emitters are present in many cosmic light sources. On the basis of the agreement between mentioned values 17 spectral lines from six singly ionized spectra have been recommended, for the first time, for plasma spectroscopy as spectral lines with reliable Stark width data. Critical analysis of the existing Stark width data is also given.

  8. Resonance ionization laser ion sources for on-line isotope separators (invited)

    International Nuclear Information System (INIS)

    Marsh, B. A.

    2014-01-01

    A Resonance Ionization Laser Ion Source (RILIS) is today considered an essential component of the majority of Isotope Separator On Line (ISOL) facilities; there are seven laser ion sources currently operational at ISOL facilities worldwide and several more are under development. The ionization mechanism is a highly element selective multi-step resonance photo-absorption process that requires a specifically tailored laser configuration for each chemical element. For some isotopes, isomer selective ionization may even be achieved by exploiting the differences in hyperfine structures of an atomic transition for different nuclear spin states. For many radioactive ion beam experiments, laser resonance ionization is the only means of achieving an acceptable level of beam purity without compromising isotope yield. Furthermore, by performing element selection at the location of the ion source, the propagation of unwanted radioactivity downstream of the target assembly is reduced. Whilst advances in laser technology have improved the performance and reliability of laser ion sources and broadened the range of suitable commercially available laser systems, many recent developments have focused rather on the laser/atom interaction region in the quest for increased selectivity and/or improved spectral resolution. Much of the progress in this area has been achieved by decoupling the laser ionization from competing ionization processes through the use of a laser/atom interaction region that is physically separated from the target chamber. A new application of gas catcher laser ion source technology promises to expand the capabilities of projectile fragmentation facilities through the conversion of otherwise discarded reaction fragments into high-purity low-energy ion beams. A summary of recent RILIS developments and the current status of laser ion sources worldwide is presented

  9. CO Spectral Line Energy Distributions in Galactic Sources: Empirical Interpretation of Extragalactic Observations

    Energy Technology Data Exchange (ETDEWEB)

    Indriolo, Nick; Bergin, E. A. [Department of Astronomy, University of Michigan, 1085 S. University Avenue, Ann Arbor, MI 48109 (United States); Goicoechea, J. R.; Cernicharo, J. [Grupo de Astrofísica Molecular, Instituto de Ciencia de Materiales de Madrid (CSIC) E-28049 Madrid (Spain); Gerin, M.; Gusdorf, A. [LERMA, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Universités, UPMC Univ. Paris 06, École normale supérieure, F-75005, Paris (France); Lis, D. C. [LERMA, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Universités, UPMC Univ. Paris 06, F-75014, Paris (France); Schilke, P., E-mail: nindriolo@stsci.edu [I. Physikalisches Institut der Universität zu Köln, Zülpicher Str. 77, D-50937 Köln (Germany)

    2017-02-10

    The relative populations in rotational transitions of CO can be useful for inferring gas conditions and excitation mechanisms at work in the interstellar medium. We present CO emission lines from rotational transitions observed with Herschel /HIFI in the star-forming cores Orion S, Orion KL, Sgr B2(M), and W49N. Integrated line fluxes from these observations are combined with those from Herschel /PACS observations of the same sources to construct CO spectral line energy distributions (SLEDs) from 5≤ J{sub u} ≤ 48. These CO SLEDs are compared to those reported in other galaxies, with the intention of empirically determining which mechanisms dominate excitation in such systems. We find that CO SLEDs in Galactic star-forming cores cannot be used to reproduce those observed in other galaxies, although the discrepancies arise primarily as a result of beam filling factors. The much larger regions sampled by the Herschel beams at distances of several megaparsecs contain significant amounts of cooler gas, which dominate the extragalactic CO SLEDs, in contrast to observations of Galactic star-forming regions, which are focused specifically on cores containing primarily hot molecular gas.

  10. A Simplified Infiltration Model for Predicting Cumulative Infiltration during Vertical Line Source Irrigation

    Directory of Open Access Journals (Sweden)

    Yanwei Fan

    2018-01-01

    Full Text Available Vertical line source irrigation is a water-saving irrigation method for enhancing direct water and nutrient delivery to the root zone, reducing soil evaporation and improving water and nutrient use efficiency. To identify its influencing factors, we performed computer simulations using the HYDRUS-2D software. The results indicate that for a given soil, the line source seepage area, but not the initial soil water content and buried depth, has a significant effect on the cumulative infiltration. We thus proposed a simplified method, taking into account the seepage area for predicting the cumulative infiltration based on the Philip model. Finally, we evaluated the accuracy of the simplified method using experimental data and found the cumulative infiltrations predicted by the simplified method were in very good agreement with the observed values, showing a low mean average error of 0.028–0.480 L, a root mean square error of 0.043–0.908 L, a percentage bias of 0.321–0.900 and a large Nash-Sutcliffe coefficient close to 1.0 (NSE ≥ 0.995. The results indicate that this simplified infiltration model, for which the only emitter parameter required is the seepage area, could provide a valuable and practical tool for irrigation design.

  11. Insulin activates single amiloride-blockable Na channels in a distal nephron cell line (A6).

    Science.gov (United States)

    Marunaka, Y; Hagiwara, N; Tohda, H

    1992-09-01

    Using the patch-clamp technique, we studied the effect of insulin on an amiloride-blockable Na channel in the apical membrane of a distal nephron cell line (A6) cultured on permeable collagen films for 10-14 days. NPo (N, number of channels per patch membrane; Po, average value of open probability of individual channels in the patch) under baseline conditions was 0.88 +/- 0.12 (SE)(n = 17). After making cell-attached patches on the apical membrane which contained Na channels, insulin (1 mU/ml) was applied to the serosal bath. While maintaining the cell-attached patch, NPo significantly increased to 1.48 +/- 0.19 (n = 17; P less than 0.001) after 5-10 min of insulin application. The open probability of Na channels was 0.39 +/- 0.01 (n = 38) under baseline condition, and increased to 0.66 +/- 0.03 (n = 38, P less than 0.001) after addition of insulin. The baseline single-channel conductance was 4pS, and neither the single-channel conductance nor the current-voltage relationship was significantly changed by insulin. These results indicate that insulin increases Na absorption in the distal nephron by increasing the open probability of the amiloride-blockable Na channel.

  12. Efficient fiber-coupled single-photon sources based on quantum dots

    DEFF Research Database (Denmark)

    Daveau, Raphaël Sura

    This thesis presents the study of solid-state quantum emitters in two dierent forms. The rst part of the thesis deals with quantum dot based single-photon sources with an emphasis on ecient photon extraction into an optical ber. The second part of the thesis covers a theoretical study of optical...... refrigeration with coupled quantum wells. Many photonic quantum information processing applications would benet from a highbrightness, ber-coupled source of triggered single photons. This thesis presents a study of such sources based on quantum dots coupled to unidirectional photonic-crystal waveguide devices...... the characterization of single quantum dots. The second method, evanescent coupling from a tapered waveguide to a microber, demonstrates a chip-to-ber coupling eciency exceeding 80 % in passive re- ection measurements. The characterization of quantum dots from this device establishes a ber-coupled source eciency of 15...

  13. Single Quantum Dot with Microlens and 3D-Printed Micro-objective as Integrated Bright Single-Photon Source.

    Science.gov (United States)

    Fischbach, Sarah; Schlehahn, Alexander; Thoma, Alexander; Srocka, Nicole; Gissibl, Timo; Ristok, Simon; Thiele, Simon; Kaganskiy, Arsenty; Strittmatter, André; Heindel, Tobias; Rodt, Sven; Herkommer, Alois; Giessen, Harald; Reitzenstein, Stephan

    2017-06-21

    Integrated single-photon sources with high photon-extraction efficiency are key building blocks for applications in the field of quantum communications. We report on a bright single-photon source realized by on-chip integration of a deterministic quantum dot microlens with a 3D-printed multilens micro-objective. The device concept benefits from a sophisticated combination of in situ 3D electron-beam lithography to realize the quantum dot microlens and 3D femtosecond direct laser writing for creation of the micro-objective. In this way, we obtain a high-quality quantum device with broadband photon-extraction efficiency of (40 ± 4)% and high suppression of multiphoton emission events with g (2) (τ = 0) < 0.02. Our results highlight the opportunities that arise from tailoring the optical properties of quantum emitters using integrated optics with high potential for the further development of plug-and-play fiber-coupled single-photon sources.

  14. Demonstration of acoustic source localization in air using single pixel compressive imaging

    Science.gov (United States)

    Rogers, Jeffrey S.; Rohde, Charles A.; Guild, Matthew D.; Naify, Christina J.; Martin, Theodore P.; Orris, Gregory J.

    2017-12-01

    Acoustic source localization often relies on large sensor arrays that can be electronically complex and have large data storage requirements to process element level data. Recently, the concept of a single-pixel-imager has garnered interest in the electromagnetics literature due to its ability to form high quality images with a single receiver paired with shaped aperture screens that allow for the collection of spatially orthogonal measurements. Here, we present a method for creating an acoustic analog to the single-pixel-imager found in electromagnetics for the purpose of source localization. Additionally, diffraction is considered to account for screen openings comparable to the acoustic wavelength. A diffraction model is presented and incorporated into the single pixel framework. In this paper, we explore the possibility of applying single pixel localization to acoustic measurements. The method is experimentally validated with laboratory measurements made in an air waveguide.

  15. LINES

    Directory of Open Access Journals (Sweden)

    Minas Bakalchev

    2015-10-01

    Full Text Available The perception of elements in a system often creates their interdependence, interconditionality, and suppression. The lines from a basic geometrical element have become the model of a reductive world based on isolation according to certain criteria such as function, structure, and social organization. Their traces are experienced in the contemporary world as fragments or ruins of a system of domination of an assumed hierarchical unity. How can one release oneself from such dependence or determinism? How can the lines become less “systematic” and forms more autonomous, and less reductive? How is a form released from modernistic determinism on the new controversial ground? How can these elements or forms of representation become forms of action in the present complex world? In this paper, the meaning of lines through the ideas of Le Corbusier, Leonidov, Picasso, and Hitchcock is presented. Spatial research was made through a series of examples arising from the projects of the architectural studio “Residential Transformations”, which was a backbone for mapping the possibilities ranging from playfulness to exactness, as tactics of transformation in the different contexts of the contemporary world.

  16. Second-line immunosuppressive treatment of childhood nephrotic syndrome: a single-center experience.

    Science.gov (United States)

    Kim, J; Patnaik, N; Chorny, N; Frank, R; Infante, L; Sethna, C

    2014-01-01

    Most cases of idiopathic nephrotic syndrome in childhood are responsive to corticosteroids. However, there is a small group of children that demonstrate steroid resistance (steroid-resistant nephrotic syndrome; SRNS), steroid dependence, or that frequently relapse (frequent-relapse steroid-sensitive nephrotic syndrome; FR-SSNS) which are more clinically difficult to treat. Therefore, second-line immunosuppressants, such as alkylating agents, calcineurin inhibitors, antimetabolites and, more recently, rituximab, have been used with varying success. The objective was to evaluate the response rates of various second-line therapies in the treatment of childhood nephrotic syndrome. A retrospective chart review of pediatric subjects with idiopathic nephrotic syndrome was conducted at a single tertiary care center (2007-2012). Drug responses were classified as complete response, partial response, and no response. Of the 188 charts reviewed, 121 children were classified as SSNS and 67 children as SRNS; 58% were classified as FR-SSNS. Sixty-five subjects were diagnosed with focal segmental glomerulosclerosis via biopsy. Follow-up ranged from 6 months to 21 years. The combined rate of complete and partial response for mycophenolate mofetil (MMF) was 65% (33/51) in SSNS and 67% (6/9) in SRNS. For tacrolimus, the response rate was 96% (22/23) for SSNS and 77% (17/22) for SRNS. Eighty-three percent (5/6) of SSNS subjects treated with rituximab went into complete remission; 60% relapsed after B-cell repletion. Eight refractory subjects were treated with combined MMF/tacrolimus/corticosteroid therapy with a 75% response rate. Our experience demonstrates that older medications can be replaced with newer ones such as MMF, tacrolimus, and rituximab with good outcomes and better side effect profiles. The treatment of refractory cases with combination therapy is promising.

  17. Second-Line Immunosuppressive Treatment of Childhood Nephrotic Syndrome: A Single-Center Experience

    Directory of Open Access Journals (Sweden)

    J. Kim

    2014-01-01

    Full Text Available Objective: Most cases of idiopathic nephrotic syndrome in childhood are responsive to corticosteroids. However, there is a small group of children that demonstrate steroid resistance (steroid-resistant nephrotic syndrome; SRNS, steroid dependence, or that frequently relapse (frequent-relapse steroid-sensitive nephrotic syndrome; FR-SSNS which are more clinically difficult to treat. Therefore, second-line immunosuppressants, such as alkylating agents, calcineurin inhibitors, antimetabolites and, more recently, rituximab, have been used with varying success. The objective was to evaluate the response rates of various second-line therapies in the treatment of childhood nephrotic syndrome. Study Design: A retrospective chart review of pediatric subjects with idiopathic nephrotic syndrome was conducted at a single tertiary care center (2007-2012. Drug responses were classified as complete response, partial response, and no response. Results: Of the 188 charts reviewed, 121 children were classified as SSNS and 67 children as SRNS; 58% were classified as FR-SSNS. Sixty-five subjects were diagnosed with focal segmental glomerulosclerosis via biopsy. Follow-up ranged from 6 months to 21 years. The combined rate of complete and partial response for mycophenolate mofetil (MMF was 65% (33/51 in SSNS and 67% (6/9 in SRNS. For tacrolimus, the response rate was 96% (22/23 for SSNS and 77% (17/22 for SRNS. Eighty-three percent (5/6 of SSNS subjects treated with rituximab went into complete remission; 60% relapsed after B-cell repletion. Eight refractory subjects were treated with combined MMF/tacrolimus/corticosteroid therapy with a 75% response rate. Conclusion: Our experience demonstrates that older medications can be replaced with newer ones such as MMF, tacrolimus, and rituximab with good outcomes and better side effect profiles. The treatment of refractory cases with combination therapy is promising.

  18. Californium-252 line sources: experimental verification of depth dose data using NTA films and dosage tables based on Paterson and Parker rules.

    Science.gov (United States)

    Iyer, P S; Gopalakrishnan, A K; Venkataraman, G

    1976-01-01

    Californium-252 promises to be an effective radium substitute in brachytherapy. In certain situations, such as cancer of the uterus, the dose rate near a linear source may be of interest. Paterson and Parker have tabulated the number of milligram hours for various active lengths of radium sources to give 1000 rad at different distances from the centre of the source. This paper presents similar results for Cf-252 (microgram hours to give 1000 rad neutron dose). The paper also reports the results of experimental measurements of neutron depth dose distributions for both single line sources and arrays. Kodak NTA films and a phantom were used for the study. The experimental results are found to agree well with the theoretically predicted results.

  19. Computer Simulation for Dispersion of Air Pollution Released from a Line Source According to Gaussian Model

    International Nuclear Information System (INIS)

    Emad, A.A.; El Shazly, S.M.; Kassem, Kh.O.

    2010-01-01

    A line source model, developed in laboratory of environmental physics, faculty of science at Qena, Egypt is proposed to describe the downwind dispersion of pollutants near roadways, at different cities in Egypt. The model is based on the Gaussian plume methodology and is used to predict air pollutants' concentrations near roadways. In this direction, simple software has been presented in this paper, developed by authors, adopted completely Graphical User Interface (GUI) technique for operating in various windows-based microcomputers. The software interface and code have been designed by Microsoft Visual basic 6.0 based on the Gaussian diffusion equation. This software is developed to predict concentrations of gaseous pollutants (eg. CO, SO 2 , NO 2 and particulates) at a user specified receptor grid

  20. Characteristics of a four element gyromagnetic nonlinear transmission line array high power microwave source

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, J. M., E-mail: jared.johnson@ttu.edu; Reale, D. V.; Garcia, R. S.; Cravey, W. H.; Neuber, A. A.; Dickens, J. C.; Mankowski, J. J. [Center for Pulsed Power and Power Electronics Department of Electrical and Computer Engineering, Texas Tech University, Lubbock, Texas 79409 (United States); Krile, J. T. [Department of Electromagnetics and Sensor Systems, Naval Surface Warfare Center - Dahlgren Division, Dahlgren, Virginia 22448 (United States)

    2016-05-15

    In this paper, a solid-state four element array gyromagnetic nonlinear transmission line high power microwave system is presented as well as a detailed description of its subsystems and general output capabilities. This frequency agile S-band source is easily adjusted from 2-4 GHz by way of a DC driven biasing magnetic field and is capable of generating electric fields of 7.8 kV/m at 10 m correlating to 4.2 MW of RF power with pulse repetition frequencies up to 1 kHz. Beam steering of the array at angles of ±16.7° is also demonstrated, and the associated general radiation pattern is detailed.

  1. Scanning laser-line source technique for nondestructive evaluation of cracks in human teeth.

    Science.gov (United States)

    Sun, Kaihua; Yuan, Ling; Shen, Zhonghua; Xu, Zhihong; Zhu, Qingping; Ni, Xiaowu; Lu, Jian

    2014-04-10

    This paper describes the first application of a remote nondestructive laser ultrasonic (LU) system for clinical diagnosis of cracks in human teeth, to our knowledge. It performs non-contact cracks detection on small-dimension teeth samples. Two extracted teeth with different types of cracks (cracked tooth and craze lines), which have different crack depths, are used as experimental samples. A series of ultrasonic waves were generated by a scanning laser-line source technique and detected with a laser-Doppler vibrometer on the two samples. The B-scan images and peak-to-peak amplitude variation curves of surface acoustic waves were obtained for evaluating the cracks' position and depth. The simulation results calculated by finite element method were combined with the experimental results for accurately measuring the depth of crack. The results demonstrate that this LU system has been successfully applied on crack evaluation of human teeth. And as a remote, nondestructive technique, it has great potential for early in vivo diagnosis of cracked tooth and even the future clinical dental tests.

  2. Synchrotron X-Ray Microdiffraction Studies of Electromigration in Interconnect lines at the Advanced Light Source

    Energy Technology Data Exchange (ETDEWEB)

    Tamura, Nobumichi; Chen, Kai; Kunz, Martin

    2009-05-01

    Synchrotron polychromatic X-ray microdiffraction is a particularly suitable technique to study in situ the effect of electromigration in metal interconnects as add spatial resolution to grain orientation and strain sensitivity. This technique has been extensively used at the Advanced Light Source to monitor changes in aluminum and copper interconnect test structures while high-density current is passed into them during accelerated tests at elevated temperature. One of the principal findings is the observation of electromigration-induced plasticity in the metal lines that appear during the very early stages of electromigration. In some of the lines, high density of geometrically necessary dislocation are formed leading to additional diffusion paths causing an enhancement of electromigration effect at test temperature. This paper presents an overview of the principal results obtained from X-ray microdiffraction studies of electromigration effects on aluminum and copper interconnects at the ALS throughout continuous efforts that spanned over a decade (1998-2008) from approximately 40 weeks of combined beamtime.

  3. Combination chemotherapy versus single-agent therapy as first- and second-line treatment in metastatic breast cancer

    DEFF Research Database (Denmark)

    Joensuu, H; Holli, K; Heikkinen, M

    1998-01-01

    PURPOSE: We report results of a randomized prospective study that compared single agents of low toxicity given both as the first-line and second-line chemotherapy with combination chemotherapy in advanced breast cancer with distant metastases. PATIENTS AND METHODS: Patients in the single-agent arm...... three times per week (CEF) followed by M 8 mg/m2 plus vinblastine (V) 6 mg/m2 every 4 weeks. Exclusion criteria included age greater than 70 years, World Health Organization (WHO) performance status greater than 2, prior chemotherapy for metastatic disease, and presence of liver metastases in patients...

  4. Compact Single-Layer Traveling-Wave Antenna DesignUsing Metamaterial Transmission Lines

    Science.gov (United States)

    Alibakhshikenari, Mohammad; Virdee, Bal Singh; Limiti, Ernesto

    2017-12-01

    This paper presents a single-layer traveling-wave antenna (TWA) that is based on composite right/left-handed (CRLH)-metamaterial (MTM) transmission line (TL) structure, which is implemented by using a combination of interdigital capacitors and dual-spiral inductive slots. By embedding dual-spiral inductive slots inside the CRLH MTM-TL results in a compact TWA. Dimensions of the proposed CRLH MTM-TL TWA is 21.5 × 30.0 mm2 or 0.372λ0 × 0.520λ0 at 5.2 GHz (center frequency). The fabricated TWA operates over 1.8-8.6 GHz with a fractional bandwidth greater than 120%, and it exhibits a peak gain and radiation efficiency of 4.2 dBi and 81%, respectively, at 5 GHz. By avoiding the use of lumped components, via-holes or defected ground structures, the proposed TWA design is economic for mass production as well as easy to integrate with wireless communication systems.

  5. Timetable Design for Minimizing Passenger Travel Time and Congestion for a Single Metro Line

    Directory of Open Access Journals (Sweden)

    Yi Shen

    2018-02-01

    Full Text Available This paper brings a proposal for a timetable optimization model for minimizing the passenger travel time and congestion for a single metro line under time-dependent demand. The model is an integer-programming model that systemically considers the passenger travel time, the capacity of trains, and the capacity of platforms. A multi-objective function and a recursive optimization method are presented to solve the optimization problem. Using the model we can obtain an efficient timetable with minimal passenger travel time and minimal number of congestion events on platforms. Moreover, by increasing the number of dispatches, the critical point from congestion state to free-flow state and the optimal timetable with minimal cost for avoiding congestion on platforms can be obtained. The effectiveness of the model is evaluated by a real example. A half-regular timetable with fixed headways in each operation period and an irregular timetable with unfixed headway are investigated for comparison.

  6. On-Chip Waveguide Coupling of a Layered Semiconductor Single-Photon Source.

    Science.gov (United States)

    Tonndorf, Philipp; Del Pozo-Zamudio, Osvaldo; Gruhler, Nico; Kern, Johannes; Schmidt, Robert; Dmitriev, Alexander I; Bakhtinov, Anatoly P; Tartakovskii, Alexander I; Pernice, Wolfram; Michaelis de Vasconcellos, Steffen; Bratschitsch, Rudolf

    2017-09-13

    Fully integrated quantum technology based on photons is in the focus of current research, because of its immense potential concerning performance and scalability. Ideally, the single-photon sources, the processing units, and the photon detectors are all combined on a single chip. Impressive progress has been made for on-chip quantum circuits and on-chip single-photon detection. In contrast, nonclassical light is commonly coupled onto the photonic chip from the outside, because presently only few integrated single-photon sources exist. Here, we present waveguide-coupled single-photon emitters in the layered semiconductor gallium selenide as promising on-chip sources. GaSe crystals with a thickness below 100 nm are placed on Si 3 N 4 rib or slot waveguides, resulting in a modified mode structure efficient for light coupling. Using optical excitation from within the Si 3 N 4 waveguide, we find nonclassicality of generated photons routed on the photonic chip. Thus, our work provides an easy-to-implement and robust light source for integrated quantum technology.

  7. Three-Level Z-Source Inverters Using a Single LC Impedance Network

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Lim, Sok Wei; Gao, Feng

    2007-01-01

    Three-level Z-source inverters are recent single-stage topological solutions proposed for buck-boost energy conversion with all favorable advantages of three-level switching retained. Despite their effectiveness in achieving voltage buck-boost conversion, existing three-level Z-source inverters use...... three-level Z-source inverters, whose output voltage can be stepped down or up using only a single LC impedance network connected between the dc input source and either a neutral-point-clamped (NPC) or dc-link cascaded inverter circuitry. Through careful design of their modulation scheme, both inverters...... can conveniently be implemented using a generic "alternative phase opposition disposition" carrier-based modulator with the appropriate triplen offset and time advance/delay added. The designed inverters, having a reduced passive component count, are lastly tested in simulation and experimentally...

  8. Three-Level Z-Source Inverters Using a Single LC Impedance Network

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Lim, Sok Wei; Gao, Feng

    2007-01-01

    Three-level Z-source inverters are recent single-stage topological solutions proposed for buck-boost energy conversion with all favorable advantages of three-level switching retained. Despite their effectiveness in achieving voltage buck-boost conversion, existing three-level Z-source inverters use...... three-level Z-source inverters, whose output voltage can be stepped down or up using only a single LC impedance network connected between the dc input source and either a neutral-point-clamped (NPC) or dc-link cascaded inverter circuitry. Through careful design of their modulation scheme, both inverters...... can function with the minimum of six device commutations per half carrier cycle (similar to that needed by a traditional buck three-level NPC inverter), while producing the correct volt-sec average and inductive voltage boosting at their ac output terminals. Physically, the designed modulation scheme...

  9. Bright quantum dot single photon source based on a low Q defect cavity

    DEFF Research Database (Denmark)

    Maier, Sebastian; Gold, Peter; Forchel, A.

    2014-01-01

    The quasi-planar single photon source presented in this paper shows an extraction efficiency of 42% without complex photonic resonator geometries or lithography steps as well as a high purity with a g2(0) value of 0.023.......The quasi-planar single photon source presented in this paper shows an extraction efficiency of 42% without complex photonic resonator geometries or lithography steps as well as a high purity with a g2(0) value of 0.023....

  10. Surface characterization of III-V MOCVD films from heterocyclic single-source precursors; Oberflaechencharakterisierung von III-V MOCVD-Filmen aus heterozyklischen Single Source Precursoren

    Energy Technology Data Exchange (ETDEWEB)

    Seemayer, Andreas

    2009-07-13

    In the present thesis the sublimation and evaporation properties of heterocyclic gallium and antimony containing single-source precursors as well as the chemical composition and morphology of the films fabricated from this were studied. The single-source precursors available by a new synthesis route were characterized concerning their evaporation properties and the obtained films studied surface-physically. By this way the process parameters were optimized and the applicability of the single-source precursors in HV-MOCVD processes studied. By evaporation experiments in the UHV it could be shown that thereby lighter ligands like ethyl- and methyl-groups lead to a lower contamination of the reaction space with carbon containing molecules. Furthermore it was expected that the 6-rings synthetized with short ligands exhibit a high stability. This however could not be confirmed. By unwanted parasitary reactions in the gaseous phase respectively dissociative sublimation in the gaseous phase a deposition of GaSb with these precursors was not possible. The 4-ring stabilized with tertiary-butyl and ethyl-groups caused in the evaporation the largest contamination of the gaseous phase, becauselonger-chain hydrocarbons exhibil only a bad pump cross section. By parasitary reactions originating elementary antimony is detectable in the gaseous phase. The films were studied concerning their chemical composition and their transport- respectively storage-conditioned surface contamination. Furthermore it has become clear that not only a purely synthetized precursor substance but also the reactor design is deciding for a successful deposition and a high film quality. First by successive optimization of the evaporation geometry it was possible to reduce the roughness of the produced GaSb films down to about 10 nm-30 nm.

  11. A single source microwave photonic filter using a novel single-mode fiber to multimode fiber coupling technique.

    Science.gov (United States)

    Chang, John; Fok, Mable P; Meister, James; Prucnal, Paul R

    2013-03-11

    In this paper we present a fully tunable and reconfigurable single-laser multi-tap microwave photonic FIR filter that utilizes a special SM-to-MM combiner to sum the taps. The filter requires only a single laser source for all the taps and a passive component, a SM-to-MM combiner, for incoherent summing of signal. The SM-to-MM combiner does not produce optical interference during signal merging and is phase-insensitive. We experimentally demonstrate an eight-tap filter with both positive and negative programmable coefficients with excellent correspondence between predicted and measured values. The magnitude response shows a clean and accurate function across the entire bandwidth, and proves successful operation of the FIR filter using a SM-to-MM combiner.

  12. MOVES-Matrix and distributed computing for microscale line source dispersion analysis.

    Science.gov (United States)

    Liu, Haobing; Xu, Xiaodan; Rodgers, Michael O; Xu, Yanzhi Ann; Guensler, Randall L

    2017-07-01

    MOVES and AERMOD are the U.S. Environmental Protection Agency's recommended models for use in project-level transportation conformity and hot-spot analysis. However, the structure and algorithms involved in running MOVES make analyses cumbersome and time-consuming. Likewise, the modeling setup process, including extensive data requirements and required input formats, in AERMOD lead to a high potential for analysis error in dispersion modeling. This study presents a distributed computing method for line source dispersion modeling that integrates MOVES-Matrix, a high-performance emission modeling tool, with the microscale dispersion models CALINE4 and AERMOD. MOVES-Matrix was prepared by iteratively running MOVES across all possible iterations of vehicle source-type, fuel, operating conditions, and environmental parameters to create a huge multi-dimensional emission rate lookup matrix. AERMOD and CALINE4 are connected with MOVES-Matrix in a distributed computing cluster using a series of Python scripts. This streamlined system built on MOVES-Matrix generates exactly the same emission rates and concentration results as using MOVES with AERMOD and CALINE4, but the approach is more than 200 times faster than using the MOVES graphical user interface. Because AERMOD requires detailed meteorological input, which is difficult to obtain, this study also recommends using CALINE4 as a screening tool for identifying the potential area that may exceed air quality standards before using AERMOD (and identifying areas that are exceedingly unlikely to exceed air quality standards). CALINE4 worst case method yields consistently higher concentration results than AERMOD for all comparisons in this paper, as expected given the nature of the meteorological data employed. The paper demonstrates a distributed computing method for line source dispersion modeling that integrates MOVES-Matrix with the CALINE4 and AERMOD. This streamlined system generates exactly the same emission rates and

  13. What Does It Take to Develop a Million Lines of Open Source Code?

    Science.gov (United States)

    Fernandez-Ramil, Juan; Izquierdo-Cortazar, Daniel; Mens, Tom

    This article presents a preliminary and exploratory study of the relationship between size, on the one hand, and effort, duration and team size, on the other, for 11 Free/Libre/Open Source Software (FLOSS) projects with current size ranging between between 0.6 and 5.3 million lines of code (MLOC). Effort was operationalised based on the number of active committers per month. The extracted data did not fit well an early version of the closed-source cost estimation model COCOMO for proprietary software, overall suggesting that, at least to some extent, FLOSS communities are more productive than closed-source teams. This also motivated the need for FLOSS-specific effort models. As a first approximation, we evaluated 16 linear regression models involving different pairs of attributes. One of our experiments was to calculate the net size, that is, to remove any suspiciously large outliers or jumps in the growth trends. The best model we found involved effort against net size, accounting for 79 percent of the variance. This model was based on data excluding a possible outlier (Eclipse), the largest project in our sample. This suggests that different effort models may be needed for certain categories of FLOSS projects. Incidentally, for each of the 11 individual FLOSS projects we were able to model the net size trends with very high accuracy (R 2 ≥ 0.98). Of the 11 projects, 3 have grown superlinearly, 5 linearly and 3 sublinearly, suggesting that in the majority of the cases accumulated complexity is either well controlled or don’t constitute a growth constraining factor.

  14. Numerical modeling of the line-source methods for thermal conductivity measurement

    Science.gov (United States)

    LEE, Y.; Keehm, Y.

    2012-12-01

    The line-source methods using a needle probe or a half-space probe have been used to measure thermal conductivity of rocks and soils in heat flow study. Though those are widely used, measurement errors have not been investigated systematically. Errors in line-source methods are caused by sample size, needle diameter, contact between a sample and a probe, and thermal conductivity of thermal compound. Since thermal conductivity of most rocks and soils ranges from 1 to 7 W/mK, a few percent of error can cause unreliable estimate of heat flow. We conducted a series of numerical modeling studies to quantify various measurement errors in the line-source methods. In the case of the needle probe with 2 mm diameter and 70 mm length, the measurement errors by the sample diameter range from 0.2% for 150 mm to 15.1% for 10 mm. When we fixed the needle length as 70 mm and varied the needle diameters from 2 to 5 mm, the errors in the measured thermal conductivity range from 0.2% for 2 mm to 24.0% for 5 mm. This clearly shows that the needle with thicker diameter does not satisfy the mathematical assumption of the infinite line-source model. Thermal resistance at the contact between the rock sample and the needle also caused considerable measurement errors. When we varied the gap between the rock sample and the needle that is filled with thermal compound (0.29 W/mK), errors range from 2.7% for 0.05 mm gap to 47.7% for 0.3 mm gap. If the gap is filled with air (0.0257 W/mK), the error ranges 80.3% for 0.05 mm gap to 87.4% for 0.1 mm gap. Numerical results show that one should take special care in reducing the gap between the rock sample and the needle probe, and should fill the gap with thermal compound, since the contact can cause significant amounts of measurement errors. In addition, the thermal conductivity of thermal compound plays an important role in reducing thermal resistance between the rock sample and the needle. The errors range from 2.4% for thermal compound with 0

  15. 77 FR 59931 - Single Source Program Expansion Supplement Award to Area Health Education Centers (AHEC) Program...

    Science.gov (United States)

    2012-10-01

    ... grantee, to coordinate the U.S. Affiliated Pacific Islands (USAPI) Nursing Program Capacity Strengthening... Program Expansion Supplement Award to Area Health Education Centers (AHEC) Program Grantee; Exception to... Competition--Single Source Program Expansion Supplement Award to Area Health Education Centers (AHEC) Program...

  16. A High-Efficiency Photonic Nanowire Single-Photon Source Featuring An Inverted Conical Taper

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    2011-01-01

    A photonic nanowire single-photon source design incorporating an inverted conical tapering is proposed. The inverted taper allows for easy electrical contacting and a high photon extraction efficiency of 89 %. Unlike cavity-based approaches, the photonic nanowire features broadband spontaneous...... emission control and an improved tolerance towards fabrication imperfections....

  17. 75 FR 30842 - Statutorily Mandated Single Source Award Program Name: National Indian Health Board

    Science.gov (United States)

    2010-06-02

    ... consistently provided education and outreach to Tribal leadership regarding the potential impact of Health Care... DEPARTMENT OF HEALTH AND HUMAN SERVICES Indian Health Service Statutorily Mandated Single Source Award Program Name: National Indian Health Board AGENCY: Indian Health Service, HHS. ACTION: Notice of...

  18. A high-efficiency electrically-pumped single-photon source based on a photonics nanowire

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    An electrically-pumped single-photon source design with a predicted efficiency of 89% is proposed. The design is based on a quantum dot embedded in a photonic nanowire with tailored ends and optimized contact electrodes. Unlike cavity-based approaches, the photonic nanowire features broadband...

  19. 77 FR 57567 - Single Source Cooperative Agreement Award for World Health Organization

    Science.gov (United States)

    2012-09-18

    ... notification to World Health Organization (WHO) as soon as possible, and any confirmed smallpox case would... DEPARTMENT OF HEALTH AND HUMAN SERVICES Single Source Cooperative Agreement Award for World Health Organization AGENCY: Department of Health and Human Services (HHS), Assistant Secretary for Preparedness and...

  20. 75 FR 48691 - Single Source Cooperative Agreement Award for the World Health Organization (WHO) To Continue...

    Science.gov (United States)

    2010-08-11

    ... Agreement Award for the World Health Organization (WHO) To Continue Development of Sustainable Influenza... countries worldwide via a cooperative agreement with the World Health Organization (WHO). The WHO has proven... DEPARTMENT OF HEALTH AND HUMAN SERVICES Single Source Cooperative Agreement Award for the World...

  1. Bright single photon source based on self-aligned quantum dot–cavity systems

    DEFF Research Database (Denmark)

    Maier, Sebastian; Gold, Peter; Forchel, Alfred

    2014-01-01

    We report on a quasi-planar quantum-dot-based single-photon source that shows an unprecedented high extraction efficiency of 42% without complex photonic resonator geometries or post-growth nanofabrication. This very high efficiency originates from the coupling of the photons emitted by a quantum...

  2. An iterated tabu search heuristic for the Single Source Capacitated Facility Location Problem

    DEFF Research Database (Denmark)

    Ho, Sin C.

    2015-01-01

    This paper discusses the Single Source Capacitated Facility Location Problem (SSCFLP) where the problem consists in determining a subset of capacitated facilities to be opened in order to satisfy the customers’ demands such that total costs are minimized. The paper presents an iterated tabu searc...... competitive with other metaheuristic approaches for solving the SSCFLP....

  3. Controlling light emission from single-photon sources using photonic nanowires

    DEFF Research Database (Denmark)

    Gregersen, Niels; Chen, Yuntian; Mørk, Jesper

    2012-01-01

    The photonic nanowire has recently emerged as an promising alternative to microcavity-based single-photon source designs. In this simple structure, a geometrical effect ensures a strong coupling between an embedded emitter and the optical mode of interest and a combination of tapers and mirrors a...... designs allowing for electrical contacting, polarization control, improved efficiency and simplified fabrication....

  4. Single-channel source separation using non-negative matrix factorization

    DEFF Research Database (Denmark)

    Schmidt, Mikkel Nørgaard

    , in which a number of methods for single-channel source separation based on non-negative matrix factorization are presented. In the papers, the methods are applied to separating audio signals such as speech and musical instruments and separating different types of tissue in chemical shift imaging....

  5. Transfection efficiency of normal and cancer cell lines and monitoring of promoter activity by single-cell bioluminescence imaging.

    Science.gov (United States)

    Horibe, Tomohisa; Torisawa, Aya; Akiyoshi, Ryutaro; Hatta-Ohashi, Yoko; Suzuki, Hirobumi; Kawakami, Koji

    2014-02-01

    The bioluminescence system (luciferase reporter assay system) is widely used to study gene expression, signal transduction and other cellular activities. Although transfection of reporter plasmid DNA to mammalian cell lines is an indispensable experimental step, the transfection efficiency of DNA varies among cell lines, and several cell lines are not suitable for this type of assay because of the low transfection efficiency. In this study, we confirm the transfection efficiency of reporter DNA to several cancer and normal cell lines after transient transfection by single-cell imaging. Luminescence images could be obtained from living single cells after transient transfection, and the calculated transfection efficiency of this method was similar to that of the conventional reporter assay using a luminometer. We attempted to measure the activity of the Bip promoter under endoplasmic reticulum stress conditions using both high and low transfection efficiency cells for plasmid DNA at the single-cell level, and observed activation of this promoter even in cells with the lowest transfection efficiency. These results show that bioluminescence imaging of single cells is a powerful tool for the analysis of gene expression based on a reporter assay using limited samples such as clinical specimens or cells from primary culture, and could provide additional information compared with the conventional assay. Copyright © 2013 John Wiley & Sons, Ltd.

  6. Music-to-Color Associations of Single-Line Piano Melodies in Non-synesthetes.

    Science.gov (United States)

    Palmer, Stephen E; Langlois, Thomas A; Schloss, Karen B

    2016-01-01

    Prior research has shown that non-synesthetes' color associations to classical orchestral music are strongly mediated by emotion. The present study examines similar cross-modal music-to-color associations for much better controlled musical stimuli: 64 single-line piano melodies that were generated from four basic melodies by Mozart, whose global musical parameters were manipulated in tempo(slow/fast), note-density (sparse/dense), mode (major/minor) and pitch-height (low/high). Participants first chose the three colors (from 37) that they judged to be most consistent with (and, later, the three that were most inconsistent with) the music they were hearing. They later rated each melody and each color for the strength of its association along four emotional dimensions: happy/sad, agitated/calm, angry/not-angry and strong/weak. The cross-modal choices showed that faster music in the major mode was associated with lighter, more saturated, yellower (warmer) colors than slower music in the minor mode. These results replicate and extend those of Palmer et al. (2013, Proc. Natl Acad. Sci. 110, 8836-8841) with more precisely controlled musical stimuli. Further results replicated strong evidence for emotional mediation of these cross-modal associations, in that the emotional ratings of the melodies were very highly correlated with the emotional associations of the colors chosen as going best/worst with the melodies (r = 0.92, 0.85, 0.82 and 0.70 for happy/sad, strong/weak,angry/not-angry and agitated/calm, respectively). The results are discussed in terms of common emotional associations forming a cross-modal bridge between highly disparate sensory inputs.

  7. Precise predictions of H2O line shapes over a wide pressure range using simulations corrected by a single measurement

    Science.gov (United States)

    Ngo, N. H.; Nguyen, H. T.; Tran, H.

    2018-03-01

    In this work, we show that precise predictions of the shapes of H2O rovibrational lines broadened by N2, over a wide pressure range, can be made using simulations corrected by a single measurement. For that, we use the partially-correlated speed-dependent Keilson-Storer (pcsdKS) model whose parameters are deduced from molecular dynamics simulations and semi-classical calculations. This model takes into account the collision-induced velocity-changes effects, the speed dependences of the collisional line width and shift as well as the correlation between velocity and internal-state changes. For each considered transition, the model is corrected by using a parameter deduced from its broadening coefficient measured for a single pressure. The corrected-pcsdKS model is then used to simulate spectra for a wide pressure range. Direct comparisons of the corrected-pcsdKS calculated and measured spectra of 5 rovibrational lines of H2O for various pressures, from 0.1 to 1.2 atm, show very good agreements. Their maximum differences are in most cases well below 1%, much smaller than residuals obtained when fitting the measurements with the Voigt line shape. This shows that the present procedure can be used to predict H2O line shapes for various pressure conditions and thus the simulated spectra can be used to deduce the refined line-shape parameters to complete spectroscopic databases, in the absence of relevant experimental values.

  8. Monitoring of seismic events from a specific source region using a single regional array: A case study

    Science.gov (United States)

    Gibbons, S. J.; Kværna, T.; Ringdal, F.

    2005-07-01

    In the monitoring of earthquakes and nuclear explosions using a sparse worldwide network of seismic stations, it is frequently necessary to make reliable location estimates using a single seismic array. It is also desirable to screen out routine industrial explosions automatically in order that analyst resources are not wasted upon detections which can, with a high level of confidence, be associated with such a source. The Kovdor mine on the Kola Peninsula of NW Russia is the site of frequent industrial blasts which are well recorded by the ARCES regional seismic array at a distance of approximately 300 km. We describe here an automatic procedure for identifying signals which are likely to result from blasts at the Kovdor mine and, wherever possible, for obtaining single array locations for such events. Carefully calibrated processing parameters were chosen using measurements from confirmed events at the mine over a one-year period for which the operators supplied Ground Truth information. Phase arrival times are estimated using an autoregressive method and slowness and azimuth are estimated using broadband f{-} k analysis in fixed frequency bands and time-windows fixed relative to the initial P-onset time. We demonstrate the improvement to slowness estimates resulting from the use of fixed frequency bands. Events can be located using a single array if, in addition to the P-phase, at least one secondary phase is found with both an acceptable slowness estimate and valid onset-time estimate. We evaluate the on-line system over a twelve month period; every event known to have occured at the mine is detected by the process and 32 out of 53 confirmed events were located automatically. The remaining events were classified as “very likely” Kovdor events and were subsequently located by an analyst. The false alarm rate is low; only 84 very likely Kovdor events were identified during the whole of 2003 and none of these were subsequently located at a large distance from

  9. First application of the Laser Ion Source and Trap (LIST) for on-line experiments at ISOLDE

    CERN Document Server

    Fink, D A; Imai, N; Blaum, K; Rothe, S; Sjoedin, M; Rossel, R E; Kron, T; Marsh, B A; Richter, S D; Cocolios, T E; Lecesne, N; Ghys, L; Pauwels, D; Rapisarda, E; Seliverstov, M D; Stora, T; Ramos, J P; Mendonca, T M; Fedosseev, V N; Lynch, K M; Wendt, K D A; Gottberg, A; Flanagan, K T; Van Beveren, C; Bastin, B; Fedorov, D V

    2013-01-01

    The Laser Ion Source and Trap (LIST) provides a new mode of operation for the resonance ionization laser ion source (RILIS) at ISOLDE/CERN, reducing the amount of surface-ionized isobaric contaminants by up to four orders of magnitude. After the first successful on-line test at ISOLDE in 2011 the LIST was further improved in terms of efficiency, selectivity, and reliability through several off-line tests at Mainz University and at ISOLDE. In September 2012, the first on-line physics experiments to use the LIST took place at ISOLDE. The measurements of the improved LIST indicate more than a twofold increase in efficiency compared to the LIST of the 2011 run. The suppression of surface-ionized francium contaminants has enabled the first in-source laser spectroscopy of Po-217 and Po-219. (C) 2013 Elsevier B.V. All rights reserved.

  10. Off-line ionization tests using the surface and the plasma ion sources of the SPES project

    International Nuclear Information System (INIS)

    Manzolaro, M.; Vasquez, J.; Montano, J.; Andrighetto, A.; Scarpa, D.; Manente, M.; Curreli, D.; Meneghetti, G.; Pavarin, D.

    2012-01-01

    The development of new target ion source systems for the selective production of exotic species (SPES) facility is currently in progress at Legnaro National Laboratories. In this context, the study of ion sources and their performance in terms of ionization efficiency and transversal emittance is a crucial point in order to maximize the available yields, particularly for short-lived isotopes. In this work, preliminary off-line ionization efficiency and emittance measurements for the SPES surface and plasma ion sources are presented. The plasma source emittance measurements are supported by dedicated numerical calculations.

  11. DESIGN, PROTOTYPE AND MEASUREMENT OF A SINGLE-CELL DEFLECTING CAVITY FOR THE ADVANCED PHOTON SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    Haipeng Wang, Guangfeng Cheng, Gianluigi Ciovati, Peter Kneisel, Robert Rimmer, Kai Tian, Larry Turlington, Alireza Nassiri, Geoff Waldschmidt

    2009-05-01

    After the design optimization of a squashed elliptical shape, single-cell, superconducting (SC) deflecting cavity at 2.815 GHz, a copper prototype has been bench measured to determine its rf properties and the effectiveness of waveguide damping of parasitic modes [1]. RF cold tests were also performed at 2K on niobium single-cell and two-cell prototype cavities. Details of impedance calculation using wakefiled analysis of the single-cell cavity are shown to meet the strict 200 mA beam stability requirement of the Advanced Photon Source (APS) at Argonne National Lab where a total of 16 single-cell cavities will be divided into two cryomodule. The design of higher-order mode (HOM) waveguide damping, the simulations of the Lorenz force detuning, and the prototype of on-cell damping are presented.

  12. Spectral lines and characteristic of temporal variations in photoionized plasmas induced with laser-produced plasma extreme ultraviolet source

    Science.gov (United States)

    Saber, I.; Bartnik, A.; Wachulak, P.; Skrzeczanowski, W.; Jarocki, R.; Fiedorowicz, H.

    2017-11-01

    Spectral lines for Kr/Ne/H2 photoionized plasma in the ultraviolet and visible (UV/Vis) wavelength ranges have been created using a laser-produced plasma (LPP) EUV source. The source is based on a double-stream gas puff target irradiated with a commercial Nd:YAG laser. The laser pulses were focused onto a gas stream, injected into a vacuum chamber synchronously with the EUV pulses. Spectral lines from photoionization in neutral Kr/Ne/H2 and up to few charged states were observed. The intense emission lines were associated with the Kr transition lines. Experimental and theoretical investigations on intensity variations for some ionic lines are presented. A decrease in the intensity with the delay time between the laser pulse and the spectrum acquisition was revealed. Electron temperature and electron density in the photoionized plasma have been estimated from the characteristic emission lines. Temperature was obtained using Boltzmann plot method, assuming that the population density of atoms and ions are considered in a local thermodynamic equilibrium (LTE). Electron density was calculated from the Stark broadening profile. The temporal evaluation of the plasma and the way of optimizing the radiation intensity of LPP EUV sources is discussed.

  13. Extreme ultraviolet digital in-line holography using a tabletop source.

    Science.gov (United States)

    Zürch, Michael; Spielmann, Christian

    2015-07-01

    Digital in-line holography (DIH) offers fast, lensless, and aberration-free imaging with diffraction-limited resolution and inherently combines phase- and amplitude-contrast imaging, as well as three-dimensional imaging. Extending this technique to shorter wavelengths allows increasing the achievable spatial and phase-contrast resolution, as well as accessing material parameters not accessible in the optical domain. In this paper, we report on DIH experiments conducted with a coherent tabletop ultrafast high harmonic source operated at 38 nm wavelength. Applying a twin-image-free reconstruction scheme optimized for highly absorbing samples, we were able to demonstrate the phase-contrast imaging of silicon nitride sheets of 15 nm thickness and the use of the strong absorption of extreme ultraviolet in matter for amplitude-contrast imaging of thin films with spatial resolution below 1 μm. High-resolution morphology determination in combination with phase-contrast imaging is of special importance in thin-film characterization and applications arising thereof.

  14. Line-Interactive Transformerless Uninterruptible Power Supply (UPS with a Fuel Cell as the Primary Source

    Directory of Open Access Journals (Sweden)

    Muhammad Iftikhar

    2018-03-01

    Full Text Available This paper presents line-interactive transformerless Uninterruptible Power Supply (UPS with a fuel cell as the prime energy source. The proposed UPS consists of three major parts (i.e., an output inverter, a unidirectional DC–DC converter, and a battery charger/discharger. Non-isolated topologies of both the unidirectional converter and battery charger/discharger ensure transformerless operation of the UPS system. A new topology of high gain converter is employed for boosting the low voltage of the fuel cell to a higher DC link voltage, with minimum semiconductor count, and high efficiency. A high-gain battery charger/discharger realizes the bidirectional operation between the DC link and the battery bank. Besides, it regulates the DC link voltage during the cold start of fuel cells and keeps the battery bank voltage to only 24 V. A new inverter control scheme is introduced that regulates the output voltage and minimizes the total harmonic distortion for non-linear loading condition. The proposed control scheme integrates proportional-resonant control with slide mode control, which improves the controller’s performance in transient conditions. The proposed UPS system is validated by developing a 1-kVA experimental prototype.

  15. The use of radioactive sources for the study of wear in refractory linings

    International Nuclear Information System (INIS)

    Courtois, G.; Hours, R.

    1960-01-01

    Following a discussion on the radioactive method for studying wear in refractory linings (description of the method, advantages and disadvantages, choice of radioactive indicator and detection), the article deals in some detail with the problems of safety involved in this technique. The two most important points discussed are: 1- the need to fix an upper limit of activity in the cast iron: the authors propose a figure of 1 mc of cobalt 60 in 500 tons; 2- the precautions necessary to remedy the diffusion of cobalt 60 in the brickwork (development of special pyro-ceramic sources). After a discussion on the international view point regarding the use of the method, a brief outline of some French projects is given, with particular reference to the case of a blast furnace. A note from the Commission interministerielle des Radioelements is given as an appendix; this deals with special conditions laid down for the use of radioelements in the determination of wear in refractory walls. (author) [fr

  16. Effect of Single or Combined Climatic and Hygienic Stress in Four Layer Lines: 1. Performance

    NARCIS (Netherlands)

    Star, L.; Kemp, B.; Anker, van den I.; Parmentier, H.K.

    2008-01-01

    Effects of long-term climatic stress (heat exposure), short-term hygienic stress [lipopolysaccharide (LPS)], or a combination of both challenges on performance of 4 layer lines were investigated. The lines were earlier characterized by natural humoral immune competence and survival rate. At 22 wk of

  17. Time-domain single-source integral equations for analyzing scattering from homogeneous penetrable objects

    KAUST Repository

    Valdés, Felipe

    2013-03-01

    Single-source time-domain electric-and magnetic-field integral equations for analyzing scattering from homogeneous penetrable objects are presented. Their temporal discretization is effected by using shifted piecewise polynomial temporal basis functions and a collocation testing procedure, thus allowing for a marching-on-in-time (MOT) solution scheme. Unlike dual-source formulations, single-source equations involve space-time domain operator products, for which spatial discretization techniques developed for standalone operators do not apply. Here, the spatial discretization of the single-source time-domain integral equations is achieved by using the high-order divergence-conforming basis functions developed by Graglia alongside the high-order divergence-and quasi curl-conforming (DQCC) basis functions of Valdés The combination of these two sets allows for a well-conditioned mapping from div-to curl-conforming function spaces that fully respects the space-mapping properties of the space-time operators involved. Numerical results corroborate the fact that the proposed procedure guarantees accuracy and stability of the MOT scheme. © 2012 IEEE.

  18. RADISH CV. MOKHOVSKIY IS A SOURCE OF MS- AND MF-LINES AT BREEDING FOR HETEROSIS

    Directory of Open Access Journals (Sweden)

    M. I. Fedorova

    2015-01-01

    Full Text Available Based on hybrid and inbreed population of radish cv. Mokhovskiy using CMS-ogura nine lines with 100% of male sterility and fertile maintainers were selected. Using the multiplex PCR, the presence of cytoplasm of Ogura type in ms-lines and its absence in mf-lines were confirmed.

  19. Coherent artifact suppression in line-field reflection confocal microscopy using a low spatial coherence light source.

    Science.gov (United States)

    Liu, Changgeng; Cao, Hui; Choma, Michael A

    2016-10-15

    Line-field reflection confocal microscopy (LF-RCM) has the potential to add a dimension of parallelization to traditional confocal microscopy while reducing the need for two-axis beam scanning. LF-RCM systems often employ light sources with a high degree of spatial coherence. This high degree of spatial coherence potentially leads to unwanted coherent artifact in the setting of nontrivial sample scattering. Here, we (a) confirm that a coherent artifact is a nontrivial problem in LF-RCM when using spatially coherent light, and (b) demonstrate that such a coherent artifact can be mitigated through the use of reduced spatial coherence line-field sources. We demonstrate coherent noise suppression in a full-pupil line-field confocal microscope using a large number of mutually incoherent emitters from a vertical-cavity surface-emitting lasers (VCSEL) array. The coherent noise from a highly scattering sample is significantly suppressed by the use of this synthesized reduced spatial coherence light source compared to a fully coherent light source. Lastly, with scattering samples, the axial confocality of line-field confocal microscopy is compromised independent of the source spatial coherence, as demonstrated by our experimental result. Our results highlight the importance of spatial coherence engineering in parallelized reflection confocal microscopy.

  20. Atoms in carbon cages as a source of interstellar diffuse lines

    International Nuclear Information System (INIS)

    Ballester, J.L.; Antoniewicz, P.R.; Smoluchowski, R.

    1990-01-01

    A model to describe the resonance absorption lines of various atoms trapped in closed carbon cages is presented. These systems may be responsible for some of the as yet unexplained diffuse interstellar bands. Model potentials for possible atom-C60 systems are obtained and used to calculate the resonance lines. The trapped atoms considered are O, N, Si, Mg, Al, Na, and S, and in all cases the resonance lines are shifted toward the red as compared to the isolated atoms. The calculated wavelengths are compared to the range of wavelengths observed for the diffuse interstellar bands, and good agreement is found for Mg and Si resonance lines. Other lines may be caused by other than resonance transitions or by trapped molecules. The oscillator strengths and the abundances are evaluated and compared with observation. Mechanisms to explain the observed band width of the lines and the existence of certain correlated pairs of lines are discussed. 56 refs

  1. 3D color reconstructions in single DMD holographic display with LED source and complex coding scheme

    Science.gov (United States)

    Chlipała, Maksymilian; Kozacki, Tomasz

    2017-06-01

    In the paper we investigate the possibility of color reconstructions of holograms with a single DMD and incoherent LED source illumination. Holographic display is built with 4F imaging system centering reconstruction volume around the DMD surface. The display design employs complex coding scheme, which allows reconstructing complex wave from a binary hologram. In order to improve the quality of reconstructed holograms time multiplexing method is used. During the optical reconstructions we analyze quality of reconstructed holograms with incoherent RGB light sources as a function of reconstruction distance, present the possibility of 3D hologram reconstruction, and investigate temporal coherence effects in holographic display with the DMD.

  2. A hybrid algorithm for stochastic single-source capacitated facility location problem with service level requirements

    Directory of Open Access Journals (Sweden)

    Hosseinali Salemi

    2016-04-01

    Full Text Available Facility location models are observed in many diverse areas such as communication networks, transportation, and distribution systems planning. They play significant role in supply chain and operations management and are one of the main well-known topics in strategic agenda of contemporary manufacturing and service companies accompanied by long-lasting effects. We define a new approach for solving stochastic single source capacitated facility location problem (SSSCFLP. Customers with stochastic demand are assigned to set of capacitated facilities that are selected to serve them. It is demonstrated that problem can be transformed to deterministic Single Source Capacitated Facility Location Problem (SSCFLP for Poisson demand distribution. A hybrid algorithm which combines Lagrangian heuristic with adjusted mixture of Ant colony and Genetic optimization is proposed to find lower and upper bounds for this problem. Computational results of various instances with distinct properties indicate that proposed solving approach is efficient.

  3. DBD plasma source operated in single-filamentary mode for therapeutic use in dermatology

    Energy Technology Data Exchange (ETDEWEB)

    Rajasekaran, Priyadarshini; Mertmann, Philipp; Bibinov, Nikita; Awakowicz, Peter [Institute for Electrical Engineering and Plasma Technology, Ruhr-Universitaet Bochum, Universitaetsstr. 150, 44801 Bochum (Germany); Wandke, Dirk [CINOGY GmbH, Max-Naeder-Str. 15, 37114 Duderstadt (Germany); Vioel, Wolfgang, E-mail: rajasekaran@aept.rub.d, E-mail: mertmann@aept.rub.d, E-mail: Nikita.Bibinov@rub.d, E-mail: dirk.wandke@cinogy.co, E-mail: vioel@hawk-hhg.d, E-mail: awakowicz@aept.rub.d [University of Applied Sciences and Arts, Faculty of Natural Sciences and Technology, Von-Ossietzky-Str. 99, 37085 Goettingen (Germany)

    2009-11-21

    Our dielectric barrier discharge (DBD) plasma source for bio-medical application comprises a copper electrode covered with ceramic. Objects of high capacitance such as the human body can be used as the opposite electrode. In this study, the DBD source is operated in single-filamentary mode using an aluminium spike as the opposite electrode, to imitate the conditions when the discharge is ignited on a raised point, such as hair, during therapeutic use on the human body. The single-filamentary discharge thus obtained is characterized using optical emission spectroscopy, numerical simulation, voltage-current measurements and microphotography. For characterization of the discharge, averaged plasma parameters such as electron distribution function and electron density are determined. Fluxes of nitric oxide (NO), ozone (O{sub 3}) and photons reaching the treated surface are simulated. The calculated fluxes are finally compared with corresponding fluxes used in different bio-medical applications.

  4. Single crystal diffractometer for solid state physics at pulsed neutron source

    International Nuclear Information System (INIS)

    Takahashi, Miwako; Abe, Hiroshi; Ishigaki, Toru

    2002-05-01

    KEK Neutron Diffraction Facility held this meeting on September 1, 2002. The objects of meeting were to discuss themes and future of single crystal diffraction of pulsed neutron source, because 3GeV/1MW intense neutron beam will be produced by the high intensity proton accelerator project after 4 year. This report was made to discuss needs of the single crystal diffractometer in the high intensity proton accelerator project for research of solid-state physics. Paper, needs of this apparatus, suggestions to how to put forward proposal and themes are included. 16 papers were read in this meeting. The subjects of these papers consisted of the neutron diffractometer such as FOX, FONDER, EXCED, SXD and it by intense pulsed neutron source, powder, MRP, high Tc superconductors, and binary alloy. (S.Y.)

  5. The Single Cell Proteome Project - Cell-Cycle Dependent Protein Expression in Breast Cancer Cell Lines

    National Research Council Canada - National Science Library

    Dovichi, Norman J

    2005-01-01

    .... Capillary sieving electrophoresis and capillary micellar electrophoresis were used to characterize proteins in single cells in one-dimensional separations, while the two techniques were combined...

  6. Towards radiocarbon dating of single foraminifera with a gas ion source

    Science.gov (United States)

    Wacker, L.; Lippold, J.; Molnár, M.; Schulz, H.

    2013-01-01

    Carbonate shells from foraminifera are often analysed for radiocarbon to determine the age of deep-sea sediments or to assess radiocarbon reservoir ages. However, a single foraminiferal test typically contains only a few micrograms of carbon, while most laboratories require more than 100 μg for radiocarbon dating with an accelerator mass spectrometry (AMS) system. The collection of the required amount of foraminifera for a single analyses is therefore time consuming and not always possible. Here, we present a convenient method to measure the radiocarbon content of foraminifera using an AMS system fitted with a gas ion source. CO2 is liberated from 150 to 1150 μg of carbonate in septum sealed vials by acid decomposition of the carbonate. The CO2 is collected on a zeolite trap and subsequently transferred to a syringe from where it is delivered to the ion source. A sample of 400 μg (50 μg C) typically gives a 12C- ion source current of 10-15 μA over 20 min, yielding a measurement precision of less than 7 per mil for a modern sample. Using this method, we were able to date a single 560 μg Cibicides pseudoungerianus test at 14,030 ± 160 radiocarbon years. Only a minor modification to our existing gas handling system was required and the system is fully automatable to further reduce the effort involved for sample preparation.

  7. Towards radiocarbon dating of single foraminifera with a gas ion source

    International Nuclear Information System (INIS)

    Wacker, L.; Lippold, J.; Molnár, M.; Schulz, H.

    2013-01-01

    Carbonate shells from foraminifera are often analysed for radiocarbon to determine the age of deep-sea sediments or to assess radiocarbon reservoir ages. However, a single foraminiferal test typically contains only a few micrograms of carbon, while most laboratories require more than 100 μg for radiocarbon dating with an accelerator mass spectrometry (AMS) system. The collection of the required amount of foraminifera for a single analyses is therefore time consuming and not always possible. Here, we present a convenient method to measure the radiocarbon content of foraminifera using an AMS system fitted with a gas ion source. CO 2 is liberated from 150 to 1150 μg of carbonate in septum sealed vials by acid decomposition of the carbonate. The CO 2 is collected on a zeolite trap and subsequently transferred to a syringe from where it is delivered to the ion source. A sample of 400 μg (50 μg C) typically gives a 12 C − ion source current of 10–15 μA over 20 min, yielding a measurement precision of less than 7 per mil for a modern sample. Using this method, we were able to date a single 560 μg Cibicides pseudoungerianus test at 14,030 ± 160 radiocarbon years. Only a minor modification to our existing gas handling system was required and the system is fully automatable to further reduce the effort involved for sample preparation.

  8. Towards radiocarbon dating of single foraminifera with a gas ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wacker, L., E-mail: wacker@phys.ethz.ch [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Lippold, J. [Heidelberg Academy of Sciences, 69120 Heidelberg (Germany); Molnar, M. [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Institute of Nuclear Research, Hungarian Academy of Sciences, 4026 Debrecen (Hungary); Schulz, H. [Institute for Geosciencies, University of Tuebingen, 72076 Tuebingen (Germany)

    2013-01-15

    Carbonate shells from foraminifera are often analysed for radiocarbon to determine the age of deep-sea sediments or to assess radiocarbon reservoir ages. However, a single foraminiferal test typically contains only a few micrograms of carbon, while most laboratories require more than 100 {mu}g for radiocarbon dating with an accelerator mass spectrometry (AMS) system. The collection of the required amount of foraminifera for a single analyses is therefore time consuming and not always possible. Here, we present a convenient method to measure the radiocarbon content of foraminifera using an AMS system fitted with a gas ion source. CO{sub 2} is liberated from 150 to 1150 {mu}g of carbonate in septum sealed vials by acid decomposition of the carbonate. The CO{sub 2} is collected on a zeolite trap and subsequently transferred to a syringe from where it is delivered to the ion source. A sample of 400 {mu}g (50 {mu}g C) typically gives a {sup 12}C{sup -} ion source current of 10-15 {mu}A over 20 min, yielding a measurement precision of less than 7 per mil for a modern sample. Using this method, we were able to date a single 560 {mu}g Cibicides pseudoungerianus test at 14,030 {+-} 160 radiocarbon years. Only a minor modification to our existing gas handling system was required and the system is fully automatable to further reduce the effort involved for sample preparation.

  9. Exposure buildup factors for a cobalt-60 point isotropic source for single and two layer slabs

    International Nuclear Information System (INIS)

    Chakarova, R.

    1992-01-01

    Exposure buildup factors for point isotropic cobalt-60 sources are calculated by the Monte Carlo method with statistical errors ranging from 1.5 to 7% for 1-5 mean free paths (mfp) thick water and iron single slabs and for 1 and 2 mfp iron layers followed by water layers 1-5 mfp thick. The computations take into account Compton scattering. The Monte Carlo data for single slab geometries are approximated by Geometric Progression formula. Kalos's formula using the calculated single slab buildup factors may be applied to reproduce the data for two-layered slabs. The presented results and discussion may help when choosing the manner in which the radiation field gamma irradiation units will be described. (author)

  10. On-chip III-V monolithic integration of heralded single photon sources and beamsplitters

    Science.gov (United States)

    Belhassen, J.; Baboux, F.; Yao, Q.; Amanti, M.; Favero, I.; Lemaître, A.; Kolthammer, W. S.; Walmsley, I. A.; Ducci, S.

    2018-02-01

    We demonstrate a monolithic III-V photonic circuit combining a heralded single photon source with a beamsplitter, at room temperature and telecom wavelength. Pulsed parametric down-conversion in an AlGaAs waveguide generates counterpropagating photons, one of which is used to herald the injection of its twin into the beamsplitter. We use this configuration to implement an integrated Hanbury-Brown and Twiss experiment, yielding a heralded second-order correlation gher(2 )(0 )=0.10 ±0.02 that confirms single-photon operation. The demonstrated generation and manipulation of quantum states on a single III-V semiconductor chip opens promising avenues towards real-world applications in quantum information.

  11. Large scale fabrication of nitrogen vacancy-embedded diamond nanostructures for single-photon source applications

    Science.gov (United States)

    Jiang, Qianqing; Li, Wuxia; Tang, Chengchun; Chang, Yanchun; Hao, Tingting; Pan, Xinyu; Ye, Haitao; Li, Junjie; Gu, Changzhi

    2016-11-01

    Some color centers in diamond can serve as quantum bits which can be manipulated with microwave pulses and read out with laser, even at room temperature. However, the photon collection efficiency of bulk diamond is greatly reduced by refraction at the diamond/air interface. To address this issue, we fabricated arrays of diamond nanostructures, differing in both diameter and top end shape, with HSQ and Cr as the etching mask materials, aiming toward large scale fabrication of single-photon sources with enhanced collection efficiency made of nitrogen vacancy (NV) embedded diamond. With a mixture of O2 and CHF3 gas plasma, diamond pillars with diameters down to 45 nm were obtained. The top end shape evolution has been represented with a simple model. The tests of size dependent single-photon properties confirmed an improved single-photon collection efficiency enhancement, larger than tenfold, and a mild decrease of decoherence time with decreasing pillar diameter was observed as expected. These results provide useful information for future applications of nanostructured diamond as a single-photon source. Project supported by the National Key Research and Development Plan of China (Grant No. 2016YFA0200402), the National Natural Science Foundation of China (Grants Nos. 11574369, 11574368, 91323304, 11174362, and 51272278), and the FP7 Marie Curie Action (project No. 295208) sponsored by the European Commission.

  12. Herschel SPIRE FTS spectral line source calibrators

    DEFF Research Database (Denmark)

    Hopwood, Rosalind; Polehampton, Edward; Valtchanov, Ivan

    2015-01-01

    We present a summary of the Herschel SPIRE/FTS calibration programme to monitor the repeatability of spectral lines. Observations of planetary nebulae and post-AGB stars are used to assess repeatability and model the asymmetry of the instrument line shape.......We present a summary of the Herschel SPIRE/FTS calibration programme to monitor the repeatability of spectral lines. Observations of planetary nebulae and post-AGB stars are used to assess repeatability and model the asymmetry of the instrument line shape....

  13. Detailed single-crystal EPR line shape measurements for the single-molecule magnets Fe8Br and Mn12-acetate

    Science.gov (United States)

    Hill, S.; Maccagnano, S.; Park, Kyungwha; Achey, R. M.; North, J. M.; Dalal, N. S.

    2002-06-01

    It is shown that our multi-high-frequency (40-200 GHz) resonant cavity technique yields distortion-free high-field electron paramagnetic resonance (EPR) spectra for single-crystal samples of the uniaxial and biaxial spin S=10 single-molecule magnets (SMM's) [Mn12O12(CH3COO)16(H2O)4].2CH3COOH.4H2O and [Fe8O2(OH)12(tacn)6]Br8.9H2O. The observed line shapes exhibit a pronounced dependence on temperature, magnetic field, and the spin quantum numbers (MS values) associated with the levels involved in the transitions. Measurements at many frequencies allow us to separate various contributions to the EPR linewidths, including significant D strain, g strain, and broadening due to the random dipolar fields of neighboring molecules. We also identify asymmetry in some of the EPR line shapes for Fe8 and a previously unobserved fine structure to some of the EPR lines for both the Fe8 and Mn12 systems. These findings prove relevant to the mechanism of quantum tunneling of magnetization in these SMM's.

  14. Resistive evaporation of superconducting Y-Ba-Cu-O thin films from a single source

    Energy Technology Data Exchange (ETDEWEB)

    Azoulay, J.; Goldschmidt, D.

    1989-06-12

    A new evaporation method of high-temperature superconducting films, the /ital resistive vaporation/ /ital from/ /ital single/ /ital source/, isreported here for the first time. The source material, inserted into a tungstenboat in a conventional vacuum system, consisted of a pulverized mixture of Cu,YF/sub 3/, and BaF/sub 2/. The handling of the source material required only grindingand mixing of the raw materials. Its deposition onto SrTiO/sub 3/ substratesyielding superconducting films with properties very similar to those obtained ina layer-by-layer resistive evaporation of these materials. In particular, aresistive transition onset at 75 K and zero resistance at /similar to/40 K, and criticalcurrents of 2000 A/cm/sup 2/ at approx.10 K have been measured. The broad transition maybe attributed to a copper concentration gradient, as measured by Auger depthprofiling, or to a residual fluorine-rich phase.

  15. Strapdown Airborne Gravimetry Quality Assessment Method Based on Single Survey Line Data: A Study by SGA-WZ02 Gravimeter.

    Science.gov (United States)

    Wang, Minghao; Wu, Meiping; Cao, Juliang; Zhang, Kaidong; Cai, Shaokun; Yu, Ruihang

    2018-01-26

    Quality assessment is an important part in the strapdown airborne gravimetry. Root mean square error (RMSE) evaluation method is a classical way to evaluate the gravimetry quality, but classical evaluation methods are preconditioned by extra flight or reference data. Thus, a method, which is able to largely conquer the premises of classical quality assessment methods and can be used in single survey line, has been developed in this paper. According to theoretical analysis, the method chooses the stability of two horizontal attitude angles, horizontal specific force and vertical specific force as the determinants of quality assessment method. The actual data, collected by SGA-WZ02 from 13 flights 21 lines in certain survey, was used to build the model and elaborate the method. To substantiate the performance of the quality assessment model, the model is applied in extra repeat line flights from two surveys. Compared with internal RMSE, standard deviation of assessment residuals are 0.23 mGal and 0.16 mGal in two surveys, which shows that the quality assessment method is reliable and stricter. The extra flights are not necessary by specially arranging the route of flights. The method, summarized from SGA-WZ02, is a feasible approach to assess gravimetry quality using single line data and is also suitable for other strapdown gravimeters.

  16. 77 FR 58404 - Announcing the Award of Two Urgent Single-Source Grants To Support Unaccompanied Alien Children...

    Science.gov (United States)

    2012-09-20

    ...] Announcing the Award of Two Urgent Single-Source Grants To Support Unaccompanied Alien Children Program...) announces the award of two urgent single-source grants from the Unaccompanied Alien Children's Program to... providing services under the Unaccompanied Alien Children's program. Award Grantee organization Location...

  17. 77 FR 61761 - Announcement of the Award of a Single-Source Grant to the Native American Fatherhood and Families...

    Science.gov (United States)

    2012-10-11

    ....612] Announcement of the Award of a Single-Source Grant to the Native American Fatherhood and Families... the award of a single-source grant to Native American Fatherhood and Families Association (NAFFA) in Mesa, AZ, to support activities promoting Responsible Fatherhood in Native American communities...

  18. 77 FR 38070 - Office of Refugee Resettlement; Announcing the Award of a Single-Source Program Expansion...

    Science.gov (United States)

    2012-06-26

    ....676] Office of Refugee Resettlement; Announcing the Award of a Single- Source Program Expansion... (BCFS) in San Antonio, TX AGENCY: Office of Refugee Resettlement, ACF, HHS. ACTION: The Office of Refugee Resettlement announces the award of a single-source program expansion supplement grant from its...

  19. 75 FR 65494 - Award of Three Single-Source Expansion Supplements to The University of Colorado Health Sciences...

    Science.gov (United States)

    2010-10-25

    ... Single-Source Expansion Supplements to The University of Colorado Health Sciences Center in Aurora, CO...), Administration on Developmental Disabilities (ADD) has awarded three single-source expansion supplements for data... people with intellectual and developmental disabilities in all facets of community life. The University...

  20. A probabilistic framework for single-sensor acoustic emission source localization in thin metallic plates

    Science.gov (United States)

    Ebrahimkhanlou, Arvin; Salamone, Salvatore

    2017-09-01

    Tracking edge-reflected acoustic emission (AE) waves can allow the localization of their sources. Specifically, in bounded isotropic plate structures, only one sensor may be used to perform these source localizations. The primary goal of this paper is to develop a three-step probabilistic framework to quantify the uncertainties associated with such single-sensor localizations. According to this framework, a probabilistic approach is first used to estimate the direct distances between AE sources and the sensor. Then, an analytical model is used to reconstruct the envelope of edge-reflected AE signals based on the source-to-sensor distance estimations and their first arrivals. Finally, the correlation between the probabilistically reconstructed envelopes and recorded AE signals are used to estimate confidence contours for the location of AE sources. To validate the proposed framework, Hsu-Nielsen pencil lead break (PLB) tests were performed on the surface as well as the edges of an aluminum plate. The localization results show that the estimated confidence contours surround the actual source locations. In addition, the performance of the framework was tested in a noisy environment simulated by two dummy transducers and an arbitrary wave generator. The results show that in low-noise environments, the shape and size of the confidence contours depend on the sources and their locations. However, at highly noisy environments, the size of the confidence contours monotonically increases with the noise floor. Such probabilistic results suggest that the proposed probabilistic framework could thus provide more comprehensive information regarding the location of AE sources.

  1. Fire Source Localization Based on Distributed Temperature Sensing by a Dual-Line Optical Fiber System.

    Science.gov (United States)

    Sun, Miao; Tang, Yuquan; Yang, Shuang; Li, Jun; Sigrist, Markus W; Dong, Fengzhong

    2016-06-06

    We propose a method for localizing a fire source using an optical fiber distributed temperature sensor system. A section of two parallel optical fibers employed as the sensing element is installed near the ceiling of a closed room in which the fire source is located. By measuring the temperature of hot air flows, the problem of three-dimensional fire source localization is transformed to two dimensions. The method of the source location is verified with experiments using burning alcohol as fire source, and it is demonstrated that the method represents a robust and reliable technique for localizing a fire source also for long sensing ranges.

  2. Differential responses to radiation and hyperthermia of cloned cell lines derived from a single human melanoma xenograft

    International Nuclear Information System (INIS)

    Rofstad, E.K.; Brustad, T.

    1984-01-01

    One uncloned and five cloned cell lines were derived from a single human melanoma xenograft. Cells from passages 7-12 were exposed to either radiation or hyperthermia (42.5 0 C, pH = 7.4) under aerobic conditions and the colony forming ability of the cells was assayed in soft agar. The five cloned lines showed individual and characteristic responses to radiation as well as to hyperthermia. The variation in the response to radiation was mainly reflected in the size of the shoulders of the survival curves rather than in the D 0 -values. The variation in the response to hyperthermia was mainly reflected in the terminal slopes of the survival curves. The survival curve of cells from the uncloned line, both when exposed to radiation and hyperthermia, was positioned in the midst of those of the cloned lines. The response of the cloned lines to radiation did not correlate with the response to hyperthermia, indicating that tumor cell subpopulations which are resistant to radiation may respond well to hyperthermia

  3. Single-crate stand-alone CAMAC control system for a negative ion source test facility

    International Nuclear Information System (INIS)

    Juras, R.C.; Ziegler, N.F.

    1979-01-01

    A single-crate CAMAC system was configured to control a negative ion source development facility at ORNL and control software was written for the crate microcomputer. The software uses inputs from a touch panel and a shaft encoder to control the various operating parameters of the test facility and uses the touch panel to display the operating status. Communication to and from the equipment at ion source potential is accomplished over optical fibers from an ORNL-built CAMAC module. A receiver at ion source potential stores the transmitted data and some of these stored values are then used to control discrete parameters of the ion source (i.e., power supply on or off). Other stored values are sent to a multiplexed digital-to-analog converter to provide analog control signals. A transmitter at ion source potential transmits discrete status information and several channels of analog data from an analog-to-digital converter back to the ground-potential receiver where it is stored to be read and displayed by the software

  4. Enhancing the brightness of electrically driven single-photon sources using color centers in silicon carbide

    Science.gov (United States)

    Khramtsov, Igor A.; Vyshnevyy, Andrey A.; Fedyanin, Dmitry Yu.

    2018-03-01

    Practical applications of quantum information technologies exploiting the quantum nature of light require efficient and bright true single-photon sources which operate under ambient conditions. Currently, point defects in the crystal lattice of diamond known as color centers have taken the lead in the race for the most promising quantum system for practical non-classical light sources. This work is focused on a different quantum optoelectronic material, namely a color center in silicon carbide, and reveals the physics behind the process of single-photon emission from color centers in SiC under electrical pumping. We show that color centers in silicon carbide can be far superior to any other quantum light emitter under electrical control at room temperature. Using a comprehensive theoretical approach and rigorous numerical simulations, we demonstrate that at room temperature, the photon emission rate from a p-i-n silicon carbide single-photon emitting diode can exceed 5 Gcounts/s, which is higher than what can be achieved with electrically driven color centers in diamond or epitaxial quantum dots. These findings lay the foundation for the development of practical photonic quantum devices which can be produced in a well-developed CMOS compatible process flow.

  5. Using the trapped energy ratio for source depth discrimination with a horizontal line array: Theory and experimental results.

    Science.gov (United States)

    Conan, Ewen; Bonnel, Julien; Nicolas, Barbara; Chonavel, Thierry

    2017-11-01

    The problem of acoustic source depth discrimination was introduced as a way to get basic information on source depth in configurations where accurate depth estimation is not feasible. It is a binary classification problem, aiming to evaluate whether the source is near the surface or submerged. Herein, the classification relies on a signal measured with a horizontal line array in shallow water. Knowing the source-array distance is not required but the source bearing has to be close to the array endfire. Signal processing relies on a normal-mode propagation model, and thus requires prior knowledge of the mode characteristics. The decision relies on an estimation of the trapped energy ratio in mode space. The performance is predicted with simulations and Monte Carlo methods, allowing one to compare several estimators based on different mode filters, and to choose an appropriate decision threshold. The impact on performance of frequency, noise level, horizontal aperture, and environmental mismatch is numerically studied. Finally, the approach is validated on experimental data acquired with a horizontal line array deployed off the coast of New Jersey, and the impact of errors in the environmental model is illustrated. The investigated approach successfully identifies a surface ship and a submerged towed source.

  6. Suite of three protein crystallography beamlines with single superconducting bend magnet as the source

    Energy Technology Data Exchange (ETDEWEB)

    MacDowell, Alastair A.; Celestre, Richard S.; Howells, Malcolm; McKinney, Wayne; Krupnick, James; Cambie, Daniella; Domning, Edward E; Duarte, Robert M.; Kelez, Nicholas; Plate, David W.; Cork, Carl W.; Earnest, Thomas N.; Dickert, Jeffery; Meigs, George; Ralston, Corie; Holton, James M.; Alber, Thomas; Berger, James M.; Agard, David A.; Padmore, Howard A.

    2004-08-01

    At the Advanced Light Source (ALS), three protein crystallography (PX) beamlines have been built that use as a source one of the three 6 Tesla single pole superconducting bending magnets (superbends) that were recently installed in the ring. The use of such single pole superconducting bend magnets enables the development of a hard x-ray program on a relatively low energy 1.9 GeV ring without taking up insertion device straight sections. The source is of relatively low power, but due to the small electron beam emittance, it has high brightness. X-ray optics are required to preserve the brightness and to match the illumination requirements for protein crystallography. This was achieved by means of a collimating premirror bent to a plane parabola, a double crystal monochromator followed by a toroidal mirror that focuses in the horizontal direction with a 2:1 demagnification. This optical arrangement partially balances aberrations from the collimating and toroidal mirrors such that a tight focused spot size is achieved. The optical properties of the beamline are an excellent match to those required by the small protein crystals that are typically measured. The design and performance of these new beamlines are described.

  7. Suite of three protein crystallography beamlines with single superconducting bend magnet as the source

    International Nuclear Information System (INIS)

    MacDowell, Alastair A.; Celestre, Richard S.; Howells, Malcolm; McKinney, Wayne; Krupnick, James; Cambie, Daniella; Domning, Edward E; Duarte, Robert M.; Kelez, Nicholas; Plate, David W.; Cork, Carl W.; Earnest, Thomas N.; Dickert, Jeffery; Meigs, George; Ralston, Corie; Holton, James M.; Alber, Thomas; Berger, James M.; Agard, David A.; Padmore, Howard A.

    2004-01-01

    At the Advanced Light Source (ALS), three protein crystallography (PX) beamlines have been built that use as a source one of the three 6 Tesla single pole superconducting bending magnets (superbends) that were recently installed in the ring. The use of such single pole superconducting bend magnets enables the development of a hard x-ray program on a relatively low energy 1.9 GeV ring without taking up insertion device straight sections. The source is of relatively low power, but due to the small electron beam emittance, it has high brightness. X-ray optics are required to preserve the brightness and to match the illumination requirements for protein crystallography. This was achieved by means of a collimating premirror bent to a plane parabola, a double crystal monochromator followed by a toroidal mirror that focuses in the horizontal direction with a 2:1 demagnification. This optical arrangement partially balances aberrations from the collimating and toroidal mirrors such that a tight focused spot size is achieved. The optical properties of the beamline are an excellent match to those required by the small protein crystals that are typically measured. The design and performance of these new beamlines are described

  8. On-line separation of native proteins by two-dimensional liquid chromatography using a single column.

    Science.gov (United States)

    Geng, Xindu; Ke, Congyu; Chen, Gang; Liu, Peng; Wang, Fei; Zhang, Huiqiang; Sun, Xuan

    2009-04-17

    This paper reports the on-line separation of native (N) proteins by two-dimensional liquid chromatography (2D-LC) using a single column with one phase (called 2D column). The 2D column exhibits excellent resolution, selectivity, and retention of proteins in the N state and functions in two retention modes--hydrophobic interaction chromatography (HIC) and weak-cation exchange chromatography (WCX). We describe a new approach to on-line buffer exchange and collection of fractions from the first retention mode and their quantitative re-injection into the same column, followed by re-separation in the second retention mode. Thus, liquid chromatography in a closed system and in an on-line manner could be successfully carried out. This method was termed on-line protein separation by 2D-LC using only a single column (on-line 2D-LC-1C). The applicability of this method was experimentally demonstrated using standard proteins and a human serum sample. The total hypothetical maximum possible peak capacity n(c,total) and total sample peak capacity n(c,total)(*) of the 2D column were 329 and 199, respectively. By comparison against several popular commercially available columns, it was found that the 2D column had not only comparable resolution and better selectivity but also some unique characteristics. This 2D-LC-1C method could be applied to the fast purification of intact proteins in the N state, such protein drugs from natural products, and recombinant proteins and also for the fast pre-fractionation of intact proteins in the "top-down" MS strategy in proteomics.

  9. Grid Integration of Single Stage Solar PV System using Three-level Voltage Source Converter

    Science.gov (United States)

    Hussain, Ikhlaq; Kandpal, Maulik; Singh, Bhim

    2016-08-01

    This paper presents a single stage solar PV (photovoltaic) grid integrated power generating system using a three level voltage source converter (VSC) operating at low switching frequency of 900 Hz with robust synchronizing phase locked loop (RS-PLL) based control algorithm. To track the maximum power from solar PV array, an incremental conductance algorithm is used and this maximum power is fed to the grid via three-level VSC. The use of single stage system with three level VSC offers the advantage of low switching losses and the operation at high voltages and high power which results in enhancement of power quality in the proposed system. Simulated results validate the design and control algorithm under steady state and dynamic conditions.

  10. Highly efficient photonic nanowire single-photon sources for quantum information applications

    DEFF Research Database (Denmark)

    Gregersen, Niels; Claudon, J.; Munsch, M.

    2013-01-01

    must feature near-unity efficiency, where the efficiency is defined as the number of detected photons per trigger, the probability g(2)(τ=0) of multi-photon emission events should be 0 and the emitted photons are required to be indistinguishable. An optically or electrically triggered quantum light......Within the emerging field of optical quantum information processing, the current challenge is to construct the basic building blocks for the quantum computing and communication systems. A key component is the singlephoton source (SPS) capable of emitting single photons on demand. Ideally, the SPS...... emitter, e.g. a nitrogen-vacancy center or a semiconductor quantum dot (QD), embedded in a solid-state semiconductor host material appears as an attractive platform for generating such single photons. However, for a QD in bulk material, the large index contrast at the semiconductor-air interface leads...

  11. Universal control and measuring system for modern classic and amorphous magnetic materials single/on-line strip testers

    Science.gov (United States)

    Zemánek, Ivan; Havlíček, Václav

    2006-09-01

    A new universal control and measuring system for classic and amorphous soft magnetic materials single/on-line strip testing has been developed at the Czech Technical University in Prague. The measuring system allows to measure magnetization characteristic and specific power losses of different tested materials (strips) at AC magnetization of arbitrary magnetic flux density waveform at wide range of frequencies 20 Hz-20 kHz. The measuring system can be used for both single strip testing in laboratories and on-line strip testing during the production process. The measuring system is controlled by two-stage master-slave control system consisting of the external PC (master) completed by three special A/D measuring plug-in boards, and local executing control unit (slave) with one-chip microprocessor 8051, connected with PC by the RS232 serial line. The "user friendly" powerful control software implemented on the PC and the effective program code for the microprocessor give possibility for full automatic measurement with high measuring power and high measuring accuracy.

  12. Thermo-Mechanical Analysis of a Single-Pass Weld Overlay and Girth Welding in Lined Pipe

    Science.gov (United States)

    Obeid, Obeid; Alfano, Giulio; Bahai, Hamid

    2017-08-01

    The paper presents a nonlinear heat-transfer and mechanical finite-element (FE) analyses of a two-pass welding process of two segments of lined pipe made of a SUS304 stainless steel liner and a C-Mn steel pipe. The two passes consist of the single-pass overlay welding (inner lap weld) of the liner with the C-Mn steel pipe for each segment and the single-pass girth welding (outer butt weld) of the two segments. A distributed power density of the moving welding torch and a nonlinear heat-transfer coefficient accounting for both radiation and convection have been used in the analysis and implemented in user subroutines for the FE code ABAQUS. The modeling procedure has been validated against previously published experimental results for stainless steel and carbon steel welding separately. The model has been then used to determine the isotherms induced by the weld overlay and the girth welding and to clarify their influence on the transient temperature field and residual stress in the lined pipe. Furthermore, the influence of the cooling time between weld overlay and girth welding and of the welding speed have been examined thermally and mechanically as they are key factors that can affect the quality of lined pipe welding.

  13. Gating circuit for single photon-counting fluorescence lifetime instruments using high repetition pulsed light sources

    International Nuclear Information System (INIS)

    Laws, W.R.; Potter, D.W.; Sutherland, J.C.

    1984-01-01

    We have constructed a circuit that permits conventional timing electronics to be used in single photon-counting fluorimeters with high repetition rate excitation sources (synchrotrons and mode-locked lasers). Most commercial time-to-amplitude and time-to-digital converters introduce errors when processing very short time intervals and when subjected to high-frequency signals. This circuit reduces the frequency of signals representing the pulsed light source (stops) to the rate of detected fluorescence events (starts). Precise timing between the start/stop pair is accomplished by using the second stop pulse after a start pulse. Important features of our design are that the circuit is insensitive to the simultaneous occurrence of start and stop signals and that the reduction in the stop frequency allows the start/stop time interval to be placed in linear regions of the response functions of commercial timing electronics

  14. A novel Alamouti transmission technique via a single RF source and a miniaturized antenna system

    DEFF Research Database (Denmark)

    Alrabadi, Osama; Papadias, Constantinos B.

    2010-01-01

    A novel space-time transmission technique that emulates Alamouti code with a single RF source is proposed in this paper. An orthogonal block of two BPSK signals is transmitted over a duration of two symbol periods by exciting one RF port of a two-element antenna system every symbol period while...... terminating the other port with its matching impedance. Besides the orthogonality of the signals, the array far-field is a linear mixture of two orthonormal basis functions onto which the BPSK signals are mapped, hence independent fading among the signals is almost always guaranteed....

  15. An improved cut-and-solve algorithm for the single-source capacitated facility location problem

    DEFF Research Database (Denmark)

    Gadegaard, Sune Lauth; Klose, Andreas; Nielsen, Lars Relund

    2017-01-01

    In this paper, we present an improved cut-and-solve algorithm for the single-source capacitated facility location problem. The algorithm consists of three phases. The first phase strengthens the integer program by a cutting plane algorithm to obtain a tight lower bound. The second phase uses a two......-level local branching heuristic to find an upper bound, and if optimality has not yet been established, the third phase uses the cut-and-solve framework to close the optimality gap. Extensive computational results are reported, showing that the proposed algorithm runs 10–80 times faster on average compared...

  16. Sythesis of metal sulfide nanomaerials via thermal decomposition of single-source percursors

    Energy Technology Data Exchange (ETDEWEB)

    Jen-La Plante, Ilan; Zeid, Tahani W.; Yang, Peidong; Mokari, Taleb

    2010-06-03

    In this report, we present a synthetic method for the formation of cuprous sulfide (Cu2S) and lead sulfide (PbS) nanomaterials directly on substrates from the thermolysis of single-source precursors. We find that the final morphology and arrangement of the nanomaterials may be controlled through the concentration of the dissolved precursors and choice of solvent. One-dimensional (1-D) morphologies may also be grown onto substrates with the addition of a metal catalyst layer through solution-liquid-solid (SLS) growth. These synthetic techniques may be expanded to other metal sulfide materials.

  17. Widely tunable single-bandpass microwave photonic filter employing a non-sliced broadband optical source.

    Science.gov (United States)

    Xue, Xiaoxiao; Zheng, Xiaoping; Zhang, Hanyi; Zhou, Bingkun

    2011-09-12

    We demonstrate a novel microwave photonic filter based on a non-coherent broadband optical source and the variable optical carrier time shift (VOCTS) method. Optical slicing which is essential conventionally is not employed in our scheme. Nevertheless, equivalent "electrical slicing" is performed by VOCTS, generating a passband free from the carrier-suppression effect. The baseband response is eliminated by using carrier-suppression or phase modulation. Single bandpass is also achieved due to the continuous-time sinusoidal impulse response. Detailed theoretical analyses are presented and agree with the experiments quite well.

  18. Proposal for a rotating analyser single crystal spectrometer at a pulsed neutron source

    International Nuclear Information System (INIS)

    Geick, R.; Tietze, H.

    1986-01-01

    We propose a new type of crystal analyser time-of-flight spectrometer for elastic and inelastic single crystal measurements at a pulsed neutron source. Using a nonuniformly rotating analyser, a flexibility of the spectrometer is achieved intermediate between that of the crystal analyser time-of-flight spectrometers like MAX and Constant-Q and the triple axis spectrometer. In detail, we discuss constant-(h/2π)ω and constant-(Q/vertical strokeQvertical stroke) scans for our spectrometer and the nonuniform rotation of the analyser necessary for these special scans. (orig.)

  19. Single Phase Current-Source Active Rectifier for Traction: Control System Design and Practical Problems

    Directory of Open Access Journals (Sweden)

    Jan Michalik

    2006-01-01

    Full Text Available This research has been motivated by industrial demand for single phase current-source active rectifier dedicated for reconstruction of older types of dc machine locomotives. This paper presents converters control structure design and simulations. The proposed converter control is based on the mathematical model and due to possible interaction with railway signaling and required low switching frequency employs synchronous PWM. The simulation results are verified by experimental tests performed on designed laboratory prototype of power of 7kVA

  20. SREM - WRS system module number 3348 for calculating the removal flux due to point, line or disc sources

    International Nuclear Information System (INIS)

    Grimstone, M.J.

    1978-06-01

    The WRS Modular Programming System has been developed as a means by which programmes may be more efficiently constructed, maintained and modified. In this system a module is a self-contained unit typically composed of one or more Fortran routines, and a programme is constructed from a number of such modules. This report describes one WRS module, the function of which is to calculate the uncollided flux and first-collision source from a disc source in a slab geometry system, a line source at the centre of a cylindrical system or a point source at the centre of a spherical system. The information given in this manual is of use both to the programmer wishing to incorporate the module in a programme, and to the user of such a programme. (author)

  1. Accuracy of Dual-Energy Virtual Monochromatic CT Numbers: Comparison between the Single-Source Projection-Based and Dual-Source Image-Based Methods.

    Science.gov (United States)

    Ueguchi, Takashi; Ogihara, Ryota; Yamada, Sachiko

    2018-03-21

    To investigate the accuracy of dual-energy virtual monochromatic computed tomography (CT) numbers obtained by two typical hardware and software implementations: the single-source projection-based method and the dual-source image-based method. A phantom with different tissue equivalent inserts was scanned with both single-source and dual-source scanners. A fast kVp-switching feature was used on the single-source scanner, whereas a tin filter was used on the dual-source scanner. Virtual monochromatic CT images of the phantom at energy levels of 60, 100, and 140 keV were obtained by both projection-based (on the single-source scanner) and image-based (on the dual-source scanner) methods. The accuracy of virtual monochromatic CT numbers for all inserts was assessed by comparing measured values to their corresponding true values. Linear regression analysis was performed to evaluate the dependency of measured CT numbers on tissue attenuation, method, and their interaction. Root mean square values of systematic error over all inserts at 60, 100, and 140 keV were approximately 53, 21, and 29 Hounsfield unit (HU) with the single-source projection-based method, and 46, 7, and 6 HU with the dual-source image-based method, respectively. Linear regression analysis revealed that the interaction between the attenuation and the method had a statistically significant effect on the measured CT numbers at 100 and 140 keV. There were attenuation-, method-, and energy level-dependent systematic errors in the measured virtual monochromatic CT numbers. CT number reproducibility was comparable between the two scanners, and CT numbers had better accuracy with the dual-source image-based method at 100 and 140 keV. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  2. A Method for Robust Strategic Railway Dispatch Applied to a Single Track Line

    DEFF Research Database (Denmark)

    Harrod, Steven

    2013-01-01

    A method is presented for global optimization of a dispatch plan assuming perfect information over a given time horizon. An example problem is solved for the North American case of a single dominant high-speed train sharing a network with a majority flow of slower trains. Initial dispatch priority...

  3. Optimization of NANOGrav's time allocation for maximum sensitivity to single sources

    International Nuclear Information System (INIS)

    Christy, Brian; Anella, Ryan; Lommen, Andrea; Camuccio, Richard; Handzo, Emma; Finn, Lee Samuel

    2014-01-01

    Pulsar timing arrays (PTAs) are a collection of precisely timed millisecond pulsars (MSPs) that can search for gravitational waves (GWs) in the nanohertz frequency range by observing characteristic signatures in the timing residuals. The sensitivity of a PTA depends on the direction of the propagating GW source, the timing accuracy of the pulsars, and the allocation of the available observing time. The goal of this paper is to determine the optimal time allocation strategy among the MSPs in the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) for a single source of GW under a particular set of assumptions. We consider both an isotropic distribution of sources across the sky and a specific source in the Virgo cluster. This work improves on previous efforts by modeling the effect of intrinsic spin noise for each pulsar. We find that, in general, the array is optimized by maximizing time spent on the best-timed pulsars, with sensitivity improvements typically ranging from a factor of 1.5 to 4.

  4. A single-phase embedded Z-source DC-AC inverter.

    Science.gov (United States)

    Kim, Se-Jin; Lim, Young-Cheol

    2014-01-01

    In the conventional DC-AC inverter consisting of two DC-DC converters with unipolar output capacitors, the output capacitor voltages of the DC-DC converters must be higher than the DC input voltage. To overcome this weakness, this paper proposes a single-phase DC-AC inverter consisting of two embedded Z-source converters with bipolar output capacitors. The proposed inverter is composed of two embedded Z-source converters with a common DC source and output AC load. Though the output capacitor voltages of the converters are relatively low compared to those of a conventional inverter, an equivalent level of AC output voltages can be obtained. Moreover, by controlling the output capacitor voltages asymmetrically, the AC output voltage of the proposed inverter can be higher than the DC input voltage. To verify the validity of the proposed inverter, experiments were performed with a DC source voltage of 38 V. By controlling the output capacitor voltages of the converters symmetrically or asymmetrically, the proposed inverter can produce sinusoidal AC output voltages. The experiments show that efficiencies of up to 95% and 97% can be achieved with the proposed inverter using symmetric and asymmetric control, respectively.

  5. Simulation and beam line experiments for the superconducting ECR ion source VENUS

    International Nuclear Information System (INIS)

    Todd, Damon S.; Leitner, Daniela; Grote, David P.; Lyneis, ClaudeM.

    2007-01-01

    The particle-in-cell code Warp has been enhanced to incorporate both two- and three-dimensional sheath extraction models giving Warp the capability of simulating entire ion beam transport systems including the extraction of beams from plasma sources. In this article we describe a method of producing initial ion distributions for plasma extraction simulations in electron cyclotron resonance (ECR) ion sources based on experimentally measured sputtering on the source biased disc. Using this initialization method, we present preliminary results for extraction and transport simulations of an oxygen beam and compare them with experimental beam imaging on a quartz viewing plate for the superconducting ECR ion source VENUS

  6. Liver MRI at 3.0 tesla: comparison of image quality and lesion detectability between single-source conventional and dual-source parallel radiofrequency transmissions.

    Science.gov (United States)

    Hwang, Jiyoung; Kim, Young Kon; Park, Min Jung; Lee, Mi Hee; Kim, Seong Hyun; Lee, Won Jae; Choi, Dongil

    2012-01-01

    To prospectively and intraindividually compare liver magnetic resonance imaging (MRI) using single-source and dual-source parallel radiofrequency (RF) transmissions at 3.0-T for image quality, lesion detectability, and lesion contrast. Ninety-nine patients with 139 liver lesions underwent liver MRI at 3.0-T. Two radiologists performed a consensus review of T2-weighted images (T2WI), heavily T2WI (HT2WI), gadoxetic acid-enhanced hepatobiliary images, and diffusion-weighted imaging using single-source and dual-source RF transmissions with regard to image quality and lesion detectability. Contrast ratios between liver lesions and liver parenchyma were also calculated. Image quality was better with dual-source than with single-source at T2WI and HT2WI (P 0.05). Dual-source RF transmission provides a better image quality with T2WI and HT2WI than with single-source. However, 2 techniques showed similar lesion detectability.

  7. Assessment of image quality of 64-row Dual Source versus Single Source CT coronary angiography on heart rate : A phantom study

    NARCIS (Netherlands)

    Dikkers, R.; Greuter, M. J. W.; Kristanto, W.; van Ooijen, P. M. A.; Sijens, P. E.; Willems, T. P.; Oudkerk, M.

    Purpose: To assess the influence of temporal resolution on image quality of computed tomographic (CT) coronary angiography by comparing 64-row Dual Source CT (DSCT) and Single Source CT (SSCT) at different heart rates. Methods: An anthropomorphic moving heart phantom was scanned at rest, and at 50

  8. A recent source modification for noble gases at the Los Alamos on-line mass analysis facility

    International Nuclear Information System (INIS)

    Balestrini, S.J.; Forman, L.

    1976-01-01

    The Los Alamos on-line mass analysis experiment at the Godiva-IV burst reactor facility has been modified to determine independent fission yields of noble gases. The gases are released from a stearate target and ionization by electron bombardment. The distance traveled by the gases from the target to the ionization chamber is 20 cm. The efficiency of the electron bombardment source is lower than that of the surface ionization source that was employed to measure the yields of Rb and Cs. But this effect is compensated by the larger quantity of target metal that is possible when using a stearate target. (Auth.)

  9. A calderón-preconditioned single source combined field integral equation for analyzing scattering from homogeneous penetrable objects

    KAUST Repository

    Valdés, Felipe

    2011-06-01

    A new regularized single source equation for analyzing scattering from homogeneous penetrable objects is presented. The proposed equation is a linear combination of a Calderón-preconditioned single source electric field integral equation and a single source magnetic field integral equation. The equation is immune to low-frequency and dense-mesh breakdown, and free from spurious resonances. Unlike dual source formulations, this equation involves operator products that cannot be discretized using standard procedures for discretizing standalone electric, magnetic, and combined field operators. Instead, the single source equation proposed here is discretized using a recently developed technique that achieves a well-conditioned mapping from div- to curl-conforming function spaces, thereby fully respecting the space mapping properties of the operators involved, and guaranteeing accuracy and stability. Numerical results show that the proposed equation and discretization technique give rise to rapidly convergent solutions. They also validate the equation\\'s resonant free character. © 2006 IEEE.

  10. Dual-source CT coronary angiography in patients with atrial fibrillation: Comparison with single-source CT

    Energy Technology Data Exchange (ETDEWEB)

    Wang Yining [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: yiningpumc@hotmail.com; Zhang Zhuhua [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: yiningpumc@sina.com; Kong Lingyan [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: klyan78@hotmail.com; Song Lan [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: sallysonglan@sina.com; Merges, Reto D. [CT Research Collaboration, Siemens Ltd. (China)], E-mail: reto.merges@siemens.com; Chen Jiuhong [CT Research Collaboration, Siemens Ltd. (China)], E-mail: jiuhong.chen@siemens.com; Jin Zhengyu [Department of Radiology, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing (China)], E-mail: jin_zhengyu@sina.com

    2008-12-15

    Objective: To evaluate the performance of dual-source computed tomography (DSCT) for the visualization of the coronary arteries in a population with atrial fibrillation (AF) compared to single-source CT (SSCT) and to explore the impact of patients' heart rate (HR) on image quality (IQ) and reconstruction timing. Methods: Thirty consecutive patients (11 male, 19 female; 69.0 {+-} 9.2 years old) with suspected coronary artery disease and permanent AF were examined on a DSCT scanner (120 kV, 400 mAs/rot, 0.33 s rotation time, 64 x 0.6 mm collimation, pitch 0.20-0.28, Siemens Somatom Definition). Patients were divided into two groups: low and medium HR group (HR {<=} 80 bpm, n = 14) and high HR group (HR > 80 bpm, n = 16). Five of the patients also underwent conventional coronary angiography (CAG). The raw data from both tube detector arrays were reconstructed as DSCT data using a routine algorithm (temporal resolution of 83 ms). The raw data from one tube detector array was reconstructed separately on the same system using a routine single source algorithm (temporal resolution of 83-165 ms) and defined as virtual SSCT data. Image quality was assessed using a four-point grading scale from excellent (1) to non-assessable (4). Results: IQ of the DSCT data was significantly better than that of the virtual SSCT data (mean score 1.33 {+-} 0.61 vs. 1.80 {+-} 1.02; Z = -8.755, P = 0.000). 98.6% of the segments shown in DSCT were diagnostic, compared with 89.9% of the segments in virtual SSCT, {chi}{sup 2} = 32.595, P = 0.000. In DSCT group, IQ of low HR group was also better than that of high HR group, although the difference was not as big (mean score 1.25 {+-} 0.52 vs. 1.38 {+-} 0.66; Z = -2.227, P = 0.026). The mean HR of low HR group and high HR group were 67.4 {+-} 8.5 beats per minute (bpm) and 94.2 {+-} 8.8 bpm (t = -8.499, P = 0.000). The range of the variation of HR was higher in high HR group than in low HR group (mean difference between maximum and minimum HR

  11. On beam shaping of the field radiated by a line source coupled to finite or infinite photonic crystals.

    Science.gov (United States)

    Ceccuzzi, Silvio; Jandieri, Vakhtang; Baccarelli, Paolo; Ponti, Cristina; Schettini, Giuseppe

    2016-04-01

    Comparison of the beam-shaping effect of a field radiated by a line source, when an ideal infinite structure constituted by two photonic crystals and an actual finite one are considered, has been carried out by means of two different methods. The lattice sums technique combined with the generalized reflection matrix method is used to rigorously investigate the radiation from the infinite photonic crystals, whereas radiation from crystals composed of a finite number of rods along the layers is analyzed using the cylindrical-wave approach. A directive radiation is observed with the line source embedded in the structure. With an increased separation distance between the crystals, a significant edge diffraction appears that provides the main radiation mechanism in the finite layout. Suitable absorbers are implemented to reduce the above-mentioned diffraction and the reflections at the boundaries, thus obtaining good agreement between radiation patterns of a localized line source coupled to finite and infinite photonic crystals, when the number of periods of the finite structure is properly chosen.

  12. The characteristics of genetically related Pseudomonas aeruginosa from diverse sources and their interaction with human cell lines.

    Science.gov (United States)

    Streeter, Klrissa; Neuman, Christina; Thompson, Jasmin; Hatje, Eva; Katouli, Mohammad

    2016-03-01

    We investigated a collection of Pseudomonas aeruginosa strains from hospitalised patients (n = 20) and various environmental sources (n = 214) for their genetic relatedness; virulence properties; antibiotic resistance; and interaction with intestinal (Caco-2), renal (A-498), and lung (Calu-3) cell lines. Using RAPD-PCR, we found high diversity among the strains irrespective of their sources, with only 6 common (C) types containing strains from both a clinical and environmental source. Environmental strains belonging to these C-types showed greater adhesion to A-498 cells than did clinical strains (17 ± 13 bacteria/cell versus 13 ± 11 bacteria/cell; p < 0.001), whereas clinical strains showed significantly greater adhesion to Calu-3 and Caco-2 cells than did environmental strains (p < 0.001 for both). The virulence genes and antibiotic resistance profiles of the strains were similar; however, the prevalence of environmental strains carrying both exoS and exoU was significantly (p < 0.0368) higher than clinical strains. While all strains were resistant to ticarcillin and ticarcillin-clavulanic acid, resistance against aztreonam, gentamicin, amikacin, piperacillin, and ceftazidime varied among environmental and clinical strains. These results suggest that environmental strains of P. aeruginosa carry virulence properties similar to clinical strains, including adhesion to various human cell lines, with some strains showing a higher adhesion to specific cell lines, indicating they may have a better ability to cause infection in those sites under predisposing conditions of the host.

  13. The on-line analysis of aerosol-delivered pharmaceuticals via single particle aerosol mass spectrometry.

    Science.gov (United States)

    Morrical, Bradley D; Balaxi, Maria; Fergenson, David

    2015-07-15

    The use of single particle aerosol mass spectrometry (SPAMS) was evaluated for the analysis of inhaled pharmaceuticals to determine the mass distribution of the individual active pharmaceutical ingredients (API) in both single ingredient and combination drug products. SPAMS is an analytical technique where the individual aerodynamic diameters and chemical compositions of many aerosol particles are determined in real-time. The analysis was performed using a Livermore Instruments SPAMS 3.0, which allowed the efficient analysis of aerosol particles with broad size distributions and can acquire data even under a very large particle load. Data similar to what would normally require roughly three days of experimentation and analysis was collected in a five minute period and analyzed automatically. The results were computed to be comparable to those returned by a typical Next Generation Impactor (NGI) particle size distribution experiment. Copyright © 2015. Published by Elsevier B.V.

  14. Absorption line profiles in a moving atmosphere - A single scattering linear perturbation theory

    Science.gov (United States)

    Hays, P. B.; Abreu, V. J.

    1989-01-01

    An integral equation is derived which linearly relates Doppler perturbations in the spectrum of atmospheric absorption features to the wind system which creates them. The perturbation theory is developed using a single scattering model, which is validated against a multiple scattering calculation. The nature and basic properties of the kernels in the integral equation are examined. It is concluded that the kernels are well behaved and that wind velocity profiles can be recovered using standard inversion techniques.

  15. Reactions and single-particle structure of nuclei near the drip lines

    International Nuclear Information System (INIS)

    Hansen, P.G.; Sherrill, B.M.

    2001-01-01

    The techniques that have allowed the study of reactions of nuclei situated at or near the neutron or proton drip line are described. Nuclei situated just inside the drip line have low nucleon separation energies and, at most, a few bound states. If the angular momentum in addition is small, large halo states are formed where the wave function of the valency nucleon extends far beyond the nuclear radius. We begin with examples of the properties of nuclear halos and of their study in radioactive-beam experiments. We then turn to the continuum states existing above the particle threshold and also discuss the possibility of exciting them from the halo states in processes that may be thought of as 'collateral damage'. Finally, we show that the experience from studies of halo states has pointed to knockout reactions as a new way to perform spectroscopic studies of more deeply bound non-halo states. Examples are given of measurements of l values and spectroscopic factors

  16. Polyquant CT: direct electron and mass density reconstruction from a single polyenergetic source

    Science.gov (United States)

    Mason, Jonathan H.; Perelli, Alessandro; Nailon, William H.; Davies, Mike E.

    2017-11-01

    Quantifying material mass and electron density from computed tomography (CT) reconstructions can be highly valuable in certain medical practices, such as radiation therapy planning. However, uniquely parameterising the x-ray attenuation in terms of mass or electron density is an ill-posed problem when a single polyenergetic source is used with a spectrally indiscriminate detector. Existing approaches to single source polyenergetic modelling often impose consistency with a physical model, such as water-bone or photoelectric-Compton decompositions, which will either require detailed prior segmentation or restrictive energy dependencies, and may require further calibration to the quantity of interest. In this work, we introduce a data centric approach to fitting the attenuation with piecewise-linear functions directly to mass or electron density, and present a segmentation-free statistical reconstruction algorithm for exploiting it, with the same order of complexity as other iterative methods. We show how this allows both higher accuracy in attenuation modelling, and demonstrate its superior quantitative imaging, with numerical chest and metal implant data, and validate it with real cone-beam CT measurements.

  17. Polyquant CT: direct electron and mass density reconstruction from a single polyenergetic source.

    Science.gov (United States)

    Mason, Jonathan H; Perelli, Alessandro; Nailon, William H; Davies, Mike E

    2017-11-02

    Quantifying material mass and electron density from computed tomography (CT) reconstructions can be highly valuable in certain medical practices, such as radiation therapy planning. However, uniquely parameterising the x-ray attenuation in terms of mass or electron density is an ill-posed problem when a single polyenergetic source is used with a spectrally indiscriminate detector. Existing approaches to single source polyenergetic modelling often impose consistency with a physical model, such as water-bone or photoelectric-Compton decompositions, which will either require detailed prior segmentation or restrictive energy dependencies, and may require further calibration to the quantity of interest. In this work, we introduce a data centric approach to fitting the attenuation with piecewise-linear functions directly to mass or electron density, and present a segmentation-free statistical reconstruction algorithm for exploiting it, with the same order of complexity as other iterative methods. We show how this allows both higher accuracy in attenuation modelling, and demonstrate its superior quantitative imaging, with numerical chest and metal implant data, and validate it with real cone-beam CT measurements.

  18. An all-silicon single-photon source by unconventional photon blockade.

    Science.gov (United States)

    Flayac, Hugo; Gerace, Dario; Savona, Vincenzo

    2015-06-10

    The lack of suitable quantum emitters in silicon and silicon-based materials has prevented the realization of room temperature, compact, stable, and integrated sources of single photons in a scalable on-chip architecture, so far. Current approaches rely on exploiting the enhanced optical nonlinearity of silicon through light confinement or slow-light propagation, and are based on parametric processes that typically require substantial input energy and spatial footprint to reach a reasonable output yield. Here we propose an alternative all-silicon device that employs a different paradigm, namely the interplay between quantum interference and the third-order intrinsic nonlinearity in a system of two coupled optical cavities. This unconventional photon blockade allows to produce antibunched radiation at extremely low input powers. We demonstrate a reliable protocol to operate this mechanism under pulsed optical excitation, as required for device applications, thus implementing a true single-photon source. We finally propose a state-of-art implementation in a standard silicon-based photonic crystal integrated circuit that outperforms existing parametric devices either in input power or footprint area.

  19. SLG(Single-Line-to-Ground Fault Location in NUGS(Neutral Un-effectively Grounded System

    Directory of Open Access Journals (Sweden)

    Zhang Wenhai

    2018-01-01

    Full Text Available This paper reviews the SLG(Single-Line-to-Ground fault location methods in NUGS(Neutral Un-effectively Grounded System, including ungrounded system, resonant grounded system and high-resistance grounded system which are widely used in Northern Europe and China. This type of fault is hard to detect and location because fault current is the sum of capacitance current of the system which is always small(about tens of amperes. The characteristics of SLG fault in NUGS and the fault location methods are introduced in the paper.

  20. Feature-based product line instantiation using source-level packages

    NARCIS (Netherlands)

    A. van Deursen (Arie); M. de Jonge (Merijn); T. Kuipers (Tobias)

    2002-01-01

    textabstractIn this paper we discuss the construction of software products from customer-specific feature selections. We address variability management with the Feature Description Language (FDL) to capture variation points of product line architectures. We describe feature packaging which covers

  1. Possible Detection of Thermal Cyclotron Lines from Small Sources within Solar Active Regions.

    Science.gov (United States)

    1983-07-01

    pairs was sampled every 10 s for both the left hand circularly polarized (LCP) and right hand circularly polarized (RCP) signals. The data were then...magnetic field strenght , temperature, density, scale length and angle. We find that thermal cyclotron lines can explain the observed total intensity and

  2. XMM-Newton Survey of Local O VII Absorption Lines in the Spectra of Galactic X-Ray Sources

    Science.gov (United States)

    Luo, Yang; Fang, Taotao; Ma, Renyi

    2018-04-01

    The detection of highly ionized metal absorption lines in the X-ray spectra of the Galactic X-ray binaries (XRBs) implies the distribution of hot gas along the sightline toward the background sources. However, the origin of this hot gas is still unclear: it can arise in the hot interstellar medium (ISM), or is intrinsic to the XRBs. In this paper, we present an XMM-Newton survey of the O VII absorption lines in the spectra of Galactic XRBs. A total of 33 XRBs were selected, with 29 low-mass XRBs and 4 high-mass XRBs. At a more than 3σ threshold, O VII absorption line was detected in 16 targets, among which 4 were newly discovered in this work. The average line equivalent width is centered around ∼20 mÅ. Additionally, we do not find strong correlations between the O VII EWs and the Galactic neutral absorption N H, the Galactic coordinates, or the distance of background targets. Such non-correlation may suggest contamination of the circumstellar material, or a lack of constraints on the line Doppler-b parameter. We also find that regardless of the direction of the XRBs, the O VII absorption lines are always detected when the flux of the background XRBs reaches a certain level, suggesting a uniform distribution of this hot gas. We estimate a ratio of 0.004–0.4 between the hot and neutral phases of the ISM. This is the second paper in the series following Fang et al. (2015), in which we focused on the local O VII absorption lines detected in the background AGN spectra. Detailed modeling of the hot ISM distribution will be investigated in a future paper.

  3. Simulation and beam line experiments for the superconducting ECRion source VENUS

    Energy Technology Data Exchange (ETDEWEB)

    Todd, Damon S.; Leitner, Daniela; Grote, David P.; Lyneis, ClaudeM.

    2007-09-10

    The particle-in-cell code Warp has been enhanced toincorporate both two- and three-dimensional sheath extraction modelsgiving Warp the capability of simulating entire ion beam transportsystems including the extraction of beams from plasma sources. In thisarticle we describe a method of producing initial ion distributions forplasma extraction simulations in electron cyclotron resonance (ECR) ionsources based on experimentally measured sputtering on the source biaseddisc. Using this initialization method, we present preliminary resultsfor extraction and transport simulations of an oxygen beam and comparethem with experimental beam imaging on a quartz viewing plate for thesuperconducting ECR ion source VENUS.

  4. Examining Sources of Error in PCR by Single-Molecule Sequencing

    Science.gov (United States)

    Potapov, Vladimir

    2017-01-01

    Next-generation sequencing technology has enabled the detection of rare genetic or somatic mutations and contributed to our understanding of disease progression and evolution. However, many next-generation sequencing technologies first rely on DNA amplification, via the Polymerase Chain Reaction (PCR), as part of sample preparation workflows. Mistakes made during PCR appear in sequencing data and contribute to false mutations that can ultimately confound genetic analysis. In this report, a single-molecule sequencing assay was used to comprehensively catalog the different types of errors introduced during PCR, including polymerase misincorporation, structure-induced template-switching, PCR-mediated recombination and DNA damage. In addition to well-characterized polymerase base substitution errors, other sources of error were found to be equally prevalent. PCR-mediated recombination by Taq polymerase was observed at the single-molecule level, and surprisingly found to occur as frequently as polymerase base substitution errors, suggesting it may be an underappreciated source of error for multiplex amplification reactions. Inverted repeat structural elements in lacZ caused polymerase template-switching between the top and bottom strands during replication and the frequency of these events were measured for different polymerases. For very accurate polymerases, DNA damage introduced during temperature cycling, and not polymerase base substitution errors, appeared to be the major contributor toward mutations occurring in amplification products. In total, we analyzed PCR products at the single-molecule level and present here a more complete picture of the types of mistakes that occur during DNA amplification. PMID:28060945

  5. An Oblivious O(1)-Approximation for Single Source Buy-at-Bulk

    KAUST Repository

    Goel, Ashish

    2009-10-01

    We consider the single-source (or single-sink) buy-at-bulk problem with an unknown concave cost function. We want to route a set of demands along a graph to or from a designated root node, and the cost of routing x units of flow along an edge is proportional to some concave, non-decreasing function f such that f(0) = 0. We present a polynomial time algorithm that finds a distribution over trees such that the expected cost of a tree for any f is within an O(1)-factor of the optimum cost for that f. The previous best simultaneous approximation for this problem, even ignoring computation time, was O(log |D|), where D is the multi-set of demand nodes. We design a simple algorithmic framework using the ellipsoid method that finds an O(1)-approximation if one exists, and then construct a separation oracle using a novel adaptation of the Guha, Meyerson, and Munagala [10] algorithm for the single-sink buy-at-bulk problem that proves an O(1) approximation is possible for all f. The number of trees in the support of the distribution constructed by our algorithm is at most 1 + log |D|. © 2009 IEEE.

  6. Single-molecule optical genome mapping of a human HapMap and a colorectal cancer cell line.

    Science.gov (United States)

    Teo, Audrey S M; Verzotto, Davide; Yao, Fei; Nagarajan, Niranjan; Hillmer, Axel M

    2015-01-01

    Next-generation sequencing (NGS) technologies have changed our understanding of the variability of the human genome. However, the identification of genome structural variations based on NGS approaches with read lengths of 35-300 bases remains a challenge. Single-molecule optical mapping technologies allow the analysis of DNA molecules of up to 2 Mb and as such are suitable for the identification of large-scale genome structural variations, and for de novo genome assemblies when combined with short-read NGS data. Here we present optical mapping data for two human genomes: the HapMap cell line GM12878 and the colorectal cancer cell line HCT116. High molecular weight DNA was obtained by embedding GM12878 and HCT116 cells, respectively, in agarose plugs, followed by DNA extraction under mild conditions. Genomic DNA was digested with KpnI and 310,000 and 296,000 DNA molecules (≥ 150 kb and 10 restriction fragments), respectively, were analyzed per cell line using the Argus optical mapping system. Maps were aligned to the human reference by OPTIMA, a new glocal alignment method. Genome coverage of 6.8× and 5.7× was obtained, respectively; 2.9× and 1.7× more than the coverage obtained with previously available software. Optical mapping allows the resolution of large-scale structural variations of the genome, and the scaffold extension of NGS-based de novo assemblies. OPTIMA is an efficient new alignment method; our optical mapping data provide a resource for genome structure analyses of the human HapMap reference cell line GM12878, and the colorectal cancer cell line HCT116.

  7. Integration of Single-Photon Sources and Detectors on GaAs

    Directory of Open Access Journals (Sweden)

    Giulia Enrica Digeronimo

    2016-10-01

    Full Text Available Quantum photonic integrated circuits (QPICs on a GaAs platform allow the generation, manipulation, routing, and detection of non-classical states of light, which could pave the way for quantum information processing based on photons. In this article, the prototype of a multi-functional QPIC is presented together with our recent achievements in terms of nanofabrication and integration of each component of the circuit. Photons are generated by excited InAs quantum dots (QDs and routed through ridge waveguides towards photonic crystal cavities acting as filters. The filters with a transmission of 20% and free spectral range ≥66 nm are able to select a single excitonic line out of the complex emission spectra of the QDs. The QD luminescence can be measured by on-chip superconducting single photon detectors made of niobium nitride (NbN nanowires patterned on top of a suspended nanobeam, reaching a device quantum efficiency up to 28%. Moreover, two electrically independent detectors are integrated on top of the same nanobeam, resulting in a very compact autocorrelator for on-chip g(2(τ measurements.

  8. A bright single-photon source based on a photonic trumpet

    DEFF Research Database (Denmark)

    Munsch, Mathieu; Malik, Nitin S.; Bleuse, Joël

    Fiber-like photonic nanowires, which are optical waveguides made of a high refractive index material n, have recently emerged as non-resonant systems providing an efficient spontaneous emission (SE) control. When they embed a quantum emitter like a quantum dot (QD), they find application to the r......Fiber-like photonic nanowires, which are optical waveguides made of a high refractive index material n, have recently emerged as non-resonant systems providing an efficient spontaneous emission (SE) control. When they embed a quantum emitter like a quantum dot (QD), they find application...... to the realization of bright sources of quantum light and, reversibly, provide an efficient interface between propagating photons and the QD. For a wire diameter ∼ λ/n (λ is the operation wavelength), the fraction of QD SE coupled to the fundamental guided mode exceeds 90%. The collection of the photons can...... be brought close to unity with a proper engineering of the wire ends. In particular, a tapering of the top wire end is necessary to achieve a directive far-field emission pattern [1]. Recently, we have realized a single-photon source featuring a needle-like taper. The source efficiency, though record...

  9. Osteocytes, not Osteoblasts or Lining Cells, are the Main Source of the RANKL Required for Osteoclast Formation in Remodeling Bone.

    Directory of Open Access Journals (Sweden)

    Jinhu Xiong

    Full Text Available The cytokine receptor activator of nuclear factor kappa B ligand (RANKL, encoded by the Tnfsf11 gene, is essential for osteoclastogenesis and previous studies have shown that deletion of the Tnfsf11 gene using a Dmp1-Cre transgene reduces osteoclast formation in cancellous bone by more than 70%. However, the Dmp1-Cre transgene used in those studies leads to recombination in osteocytes, osteoblasts, and lining cells making it unclear whether one or more of these cell types produce the RANKL required for osteoclast formation in cancellous bone. Because osteoblasts, osteocytes, and lining cells have distinct locations and functions, distinguishing which of these cell types are sources of RANKL is essential for understanding the orchestration of bone remodeling. To distinguish between these possibilities, we have now created transgenic mice expressing the Cre recombinase under the control of regulatory elements of the Sost gene, which is expressed in osteocytes but not osteoblasts or lining cells in murine bone. Activity of the Sost-Cre transgene in osteocytes, but not osteoblast or lining cells, was confirmed by crossing Sost-Cre transgenic mice with tdTomato and R26R Cre-reporter mice, which express tdTomato fluorescent protein or LacZ, respectively, only in cells expressing the Cre recombinase or their descendants. Deletion of the Tnfsf11 gene in Sost-Cre mice led to a threefold decrease in osteoclast number in cancellous bone and increased cancellous bone mass, mimicking the skeletal phenotype of mice in which the Tnfsf11 gene was deleted using the Dmp1-Cre transgene. These results demonstrate that osteocytes, not osteoblasts or lining cells, are the main source of the RANKL required for osteoclast formation in remodeling cancellous bone.

  10. X-ray photoelectron microscope with a compact x-ray source generated by line-focused laser irradiation

    International Nuclear Information System (INIS)

    Yamaguchi, N.; Okamoto, Y.; Hara, T.; Takahashi, Z.; Nishimura, Y.; Sakata, A.; Watanabe, K.; Azuma, H.

    2004-01-01

    Full text: A laboratory-sized microscopic system of x-ray photoelectrons has been developing using a compact x-ray source produced by line-focused laser irradiation. The system is a scanning type photoelectron microscope where x-ray beam is micro-focused via a Schwartzschild optics. A compact laser-plasma x-ray source has been developed with a YAG laser system, a line-focus lens system, a tape-target driving system and a debris prevention system, that was operated at repetition rate of 10 Hz or 50 Hz. X-rays were delivered along line plasma whose length was 0.6 to 11 mm with higher intensity than that from a point-focused source. Because the transition line of Al V (13.1 nm) was prominent in the soft x-ray spectrum when the Al tape target irradiated at the lower power density of 10 11 W/cm 2 , the 13.1 nm x-ray was used as an excitation source. The Schwartzschild optics was set on the beamline at a distance about 1 m from the source, which was coated with Mo/Si multilayers for 13.1 nm x-ray. The designed demagnification is 224 that was confirmed in the previous experiment. Therefore, an x-ray micro spot of sub-micron size can be formed on a sample surface when the source size is less than about 0.2 mm. Samples were set on a two-axis high-precision piezo stage mounted to a four-axis manipulator. The electron energy analyzer was a spherical capacitor analyzer with mean diameter of 279.4 mm. The electron detector was a microchannel plate (MCP) with a phosphor screen and the optical image of electrons on the exit plane of the analyzer was taken and recorded by using an ultra low dark noise CCD camera, that was suited for detection of vast photoelectrons excited by x-ray pulse of ns-order duration. We performed spatial resolution test measurements by using a GaAs wafer coated with photo-resist that formed a stripe pattern. The spatial resolution less than 3 micron has been obtained from the variation of As 3d electron intensity along the position of the GaAs sample

  11. Mixed convection in the thermal plume above a horizontal line source of heat in a porous medium of infinite extent

    International Nuclear Information System (INIS)

    Cheng, P.; Zheng, T.M.

    1986-01-01

    An analysis is performed to study the effects of transverse thermal dispersion and inertia on the mixed convection boundary layer flow in the thermal plume above a horizontal line source in a porous medium of infinite extent. A local similarity solution is obtained where the dependent and independent variables are scaled to a mixed convection parameter applicable at both the free- and forced-convection limits. The solution is valid from the free-convection dominated region near the heat source to that of the forced-convection dominated region away from the source. Numerical computations of the temperature and vertical velocity profiles were carried out for the cases of air, water and silicon oil for a wide range of the mixed convection parameter. The effects of the transverse thermal dispersion and inertia on the heat transfer and fluid flow characteristics from free- to forced-convection limits are illustrated

  12. Novel Family of Single-Phase Modified Impedance-Source Buck-Boost Multilevel Inverters with Reduced Switch Count

    DEFF Research Database (Denmark)

    Husev, Oleksandr; Strzelecki, Ryszard; Blaabjerg, Frede

    2016-01-01

    This paper describes novel single-phase solutions with increased inverter voltage levels derived by means of a nonstandard inverter configuration and impedance source networks. Operation principles based on special modulation techniques are presented. Detailed component design guidelines along wi...

  13. [Coronary CT angiography using a prospective protocol. Comparison of image quality and radiation dose between dual source CT and single source CT].

    Science.gov (United States)

    Duarte, R; Miranda, D; Fernández-Pérez, G; Costa, J C

    2013-01-01

    To compare the image quality and radiation dose in a group of patients undergoing coronary CT angiography using a 128-slice dual source helical CT scanner with high pitch alto and prospective acquisition with those in a group of patients with similar clinical characteristics undergoing coronary CT angiography using a 128-slice single-source CT scanner with prospective sequential acquisition. We included 80 patients with heart rates ≤65 beats/min: 40 underwent sequential 128-slice single source CT with prospective synchronization and the other 40 underwent 128-slice dual source helical CT with high pitch and prospective synchronization. Two radiologists independently assessed the quality of the images of the coronary arteries on the 80 coronary CT angiograms: image quality was classified on a four-point scale in which 1 represented excellent and 4 deficient. The effective dose of radiation was also calculated. The clinical characteristics of the patients in the two groups were similar. The image quality obtained with dual source CT was significantly better than that obtained with single source CT (P=0.006). The mean effective dose of radiation in the group undergoing dual source CT was 36% lower than in the group undergoing single source CT (1.4±0.6 mSv vs. 2.2±0.9 mSv; Psource CT with prospective acquisition and 128-slice dual source helical CT with high pitch and prospective acquisition provide good image quality and low effective doses of radiation, 128-slice dual source helical CT with prospective acquisition provides better image quality and results in a lower effective dose of radiation. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  14. Differential-interference-contrast digital in-line holography microscopy based on a single-optical-element.

    Science.gov (United States)

    Zhang, Yuchao; Xie, Changqing

    2015-11-01

    Both digital in-line holography (DIH) and zone plate-based microscopy have received considerable interest as powerful imaging tools. However, the former suffers from a twin-image noise problem. The latter suffers from low efficiency and difficulty in fabrication. Here, we present an effective and efficient phase-contrast imaging approach, named differential-interference-contrast digital in-line holography (DIC-DIH), by using a single optical element to split the incident light into a plane wave and a converging spherical wave and generate a two-dimensional (2D) DIC effect simultaneously. Specifically, to improve image contrast, we present a new single optical element, termed 2D DIC compound photon sieves, by combining two overlaid binary gratings and a compound photon sieve through two logical XOR operations. The proof-of-concept experiments demonstrate that the proposed technique can eliminate the twin-image noise problem and improve image contrast with high efficiency. Additionally, we present an example of the phase-contrast imaging nonuniform thick photoresist development process.

  15. Analysis of T-DNA/Host-Plant DNA Junction Sequences in Single-Copy Transgenic Barley Lines

    Directory of Open Access Journals (Sweden)

    Joanne G. Bartlett

    2014-01-01

    Full Text Available Sequencing across the junction between an integrated transfer DNA (T-DNA and a host plant genome provides two important pieces of information. The junctions themselves provide information regarding the proportion of T-DNA which has integrated into the host plant genome, whilst the transgene flanking sequences can be used to study the local genetic environment of the integrated transgene. In addition, this information is important in the safety assessment of GM crops and essential for GM traceability. In this study, a detailed analysis was carried out on the right-border T-DNA junction sequences of single-copy independent transgenic barley lines. T-DNA truncations at the right-border were found to be relatively common and affected 33.3% of the lines. In addition, 14.3% of lines had rearranged construct sequence after the right border break-point. An in depth analysis of the host-plant flanking sequences revealed that a significant proportion of the T-DNAs integrated into or close to known repetitive elements. However, this integration into repetitive DNA did not have a negative effect on transgene expression.

  16. Xenon gas field ion source from a single-atom tip

    Science.gov (United States)

    Lai, Wei-Chiao; Lin, Chun-Yueh; Chang, Wei-Tse; Li, Po-Chang; Fu, Tsu-Yi; Chang, Chia-Seng; Tsong, T. T.; Hwang, Ing-Shouh

    2017-06-01

    Focused ion beam (FIB) systems have become powerful diagnostic and modification tools for nanoscience and nanotechnology. Gas field ion sources (GFISs) built from atomic-size emitters offer the highest brightness among all ion sources and thus can improve the spatial resolution of FIB systems. Here we show that the Ir/W(111) single-atom tip (SAT) can emit high-brightness Xe+ ion beams with a high current stability. The ion emission current versus extraction voltage was analyzed from 150 K up to 309 K. The optimal emitter temperature for maximum Xe+ ion emission was ˜150 K and the reduced brightness at the Xe gas pressure of 1 × 10-4 torr is two to three orders of magnitude higher than that of a Ga liquid metal ion source, and four to five orders of magnitude higher than that of a Xe inductively coupled plasma ion source. Most surprisingly, the SAT emitter remained stable even when operated at 309 K. Even though the ion current decreased with increasing temperature, the current at room temperature (RT) could still reach over 1 pA when the gas pressure was higher than 1 × 10-3 torr, indicating the feasibility of RT-Xe-GFIS for application to FIB systems. The operation temperature of Xe-SAT-GFIS is considerably higher than the cryogenic temperature required for the helium ion microscope (HIM), which offers great technical advantages because only simple or no cooling schemes can be adopted. Thus, Xe-GFIS-FIB would be easy to implement and may become a powerful tool for nanoscale milling and secondary ion mass spectroscopy.

  17. The Impact of Electronic Medical Records on Hospital-Acquired Adverse Safety Events: Differential Effects Between Single-Source and Multiple-Source Systems.

    Science.gov (United States)

    Bae, Jaeyong; Rask, Kimberly J; Becker, Edmund R

    The objective was to examine differential impacts between single-source and multiple-source electronic medical record (EMR) systems, as measured by number of vendor products, on hospital-acquired patient safety events. The data source was the 2009-2010 State Inpatient Databases of the Healthcare Cost and Utilization Project for California, New York, and Florida, and the Information Technology Supplement to the American Hospital Association's Annual Survey. Multivariable regression analyses were conducted to estimate the differential impacts of EMRs between single-source and multiple-source EMR systems on hospital-acquired patient safety events. In all, 1.98% of adult surgery hospitalizations had at least 1 hospital-acquired patient safety event. Basic EMRs with a single vendor or self-developed EMR systems were associated with a significant decrease in patient safety events by 0.38 percentage point, or 19.2%, whereas basic EMRs with multiple vendors had an insignificant association. A single-source EMR system enhances the impact of EMRs on reducing patient safety events.

  18. On-line monitoring system development for single-phase flow accelerated corrosion

    International Nuclear Information System (INIS)

    Lee, Na Young; Lee, Seung Gi; Ryu, Kyung Ha; Hwang, Il Soon

    2007-01-01

    Aged nuclear piping has been reported to undergo corrosion-induced accelerated failures, often without giving signatures to current inspection campaigns. Therefore, we need diverse sensors which can cover a wide area in an on-line application. We suggest an integrated approach to monitor the flow accelerated corrosion (FAC) susceptible piping. Since FAC is a combined phenomenon, we need to monitor as many parameters as possible and that cover wide area, since we do not know where the FAC occurs. For this purpose, we introduce the wearing rate model which focuses on the electrochemical parameters. Using this model, we can predict the wearing rate and then compare testing results. Through analysis we identified feasibility and then developed electrochemical sensors for high temperature application; we also introduced a mechanical monitoring system which is still under development. To support the validation of the monitored results, we adopted high temperature ultrasonic transducer (UT), which shows good resolution in the testing environment. As such, all the monitored results can be compared in terms of thickness. Our validation tests demonstrated the feasibility of sensors. To support direct thickness measurement for a wide-area, the direct current potential drop (DCPD) method will be researched to integrate into the developed framework

  19. Single-bunch beam breakup in a dielectric-lined waveguide

    International Nuclear Information System (INIS)

    Ng, King-Yuen.

    1992-08-01

    We examine beam breakup of a 100 nC I mm-long (rms) source bunch inside a cylindrical dielectric waveguide, with dielectric ε = 2.65 filling the radius between 7.5 and 9.0 mm. Only ∼ 78% of the bunch with an initial offset of 0.3 mm survives the passage of the 3.75 m waveguide. The loss is mainly due to the large deflections of some particles that are slowed down to nearly zero velocity. As a result, quadrupole focussing of any sort will not help. However, if the waveguide is shortened to 3.3 m, the loss reduces to only 5.5%

  20. 48 CFR 245.7101-3 - DD Form 1348-1, DoD Single Line Item Release/Receipt Document.

    Science.gov (United States)

    2010-10-01

    ... PROPERTY Plant Clearance Forms 245.7101-3 DD Form 1348-1, DoD Single Line Item Release/Receipt Document. Use for shipments of excess industrial plant equipment and contractor inventory redistribution system...

  1. Type 2 Active Galactic Nuclei with Double-peaked [O III] Lines. II. Single AGNs with Complex Narrow-line Region Kinematics are More Common than Binary AGNs

    Science.gov (United States)

    Shen, Yue; Liu, Xin; Greene, Jenny E.; Strauss, Michael A.

    2011-07-01

    Approximately 1% of low-redshift (z interpreted as either due to kinematics, such as biconical outflows and/or disk rotation of the narrow line region (NLR) around single black holes, or due to the relative motion of two distinct NLRs in a merging pair of AGNs. Here, we report follow-up near-infrared (NIR) imaging and optical slit spectroscopy of 31 double-peaked [O III] type 2 AGNs drawn from the Sloan Digital Sky Survey (SDSS) parent sample presented in Liu et al. The NIR imaging traces the old stellar population in each galaxy, while the optical slit spectroscopy traces the NLR gas. These data reveal a mixture of origins for the double-peaked feature. Roughly 10% of our objects are best explained by binary AGNs at (projected) kpc-scale separations, where two stellar components with spatially coincident NLRs are seen. ~50% of our objects have [O III] emission offset by a few kpc, corresponding to the two velocity components seen in the SDSS spectra, but there are no spatially coincident double stellar components seen in the NIR imaging. For those objects with sufficiently high-quality slit spectra, we see velocity and/or velocity dispersion gradients in [O III] emission, suggestive of the kinematic signatures of a single NLR. The remaining ~40% of our objects are ambiguous and will need higher spatial resolution observations to distinguish between the two scenarios. Our observations therefore favor the kinematics scenario with a single AGN for the majority of these double-peaked [O III] type 2 AGNs. We emphasize the importance of combining imaging and slit spectroscopy in identifying kpc-scale binary AGNs, i.e., in no cases does one of these alone allow an unambiguous identification. We estimate that ~0.5%-2.5% of the z ~ 150 km s-1. Based in part on observations obtained with the 6.5 m Magellan telescopes located at Las Campanas Observatory, Chile, and with the Apache Point Observatory 3.5 m telescope, which is owned and operated by the Astrophysical Research

  2. Performance Evaluation of the Single-Phase Split-Source Inverter Using an Alternative DC-AC Configuration

    DEFF Research Database (Denmark)

    Abdelhakim, Ahmed; Mattavelli, Paolo; Davari, Pooya

    2018-01-01

    This paper investigates and evaluates the performance of a single-phase split-source inverter (SSI), where an alternative unidirectional dc-ac configuration is used. Such configuration is utilized in order to use two common-cathode diodes in a single-device instead of using two separate diodes, r...

  3. 500 nm Continuous Wave Tunable SingleFrequency MidIR Light Source for C–H Spectroscopy

    DEFF Research Database (Denmark)

    Høgstedt, Lasse; Jensen, Ole Bjarlin; Dam, Jeppe Seidelin

    2012-01-01

    A computer controlled tunable mid-IR light source, based on single resonant difference frequency generation (DFG), is experimentally investigated. The DFG process is pumped by an external cavity tapered diode laser, tunable over a spectral range of 30 nm. Grating feedback to the single mode channel...

  4. Reference-Frame-Independent and Measurement-Device-Independent Quantum Key Distribution Using One Single Source

    Science.gov (United States)

    Li, Qian; Zhu, Changhua; Ma, Shuquan; Wei, Kejin; Pei, Changxing

    2018-04-01

    Measurement-device-independent quantum key distribution (MDI-QKD) is immune to all detector side-channel attacks. However, practical implementations of MDI-QKD, which require two-photon interferences from separated independent single-photon sources and a nontrivial reference alignment procedure, are still challenging with current technologies. Here, we propose a scheme that significantly reduces the experimental complexity of two-photon interferences and eliminates reference frame alignment by the combination of plug-and-play and reference frame independent MDI-QKD. Simulation results show that the secure communication distance can be up to 219 km in the finite-data case and the scheme has good potential for practical MDI-QKD systems.

  5. I19, the small-molecule single-crystal diffraction beamline at Diamond Light Source.

    Science.gov (United States)

    Nowell, Harriott; Barnett, Sarah A; Christensen, Kirsten E; Teat, Simon J; Allan, David R

    2012-05-01

    The dedicated small-molecule single-crystal X-ray diffraction beamline (I19) at Diamond Light Source has been operational and supporting users for over three years. I19 is a high-flux tunable-wavelength beamline and its key details are described in this article. Much of the work performed on the beamline involves structure determination from small and weakly diffracting crystals. Other experiments that have been supported to date include structural studies at high pressure, studies of metastable species, variable-temperature crystallography, studies involving gas exchange in porous materials and structural characterizations that require analysis of the diffuse scattering between Bragg reflections. A range of sample environments to facilitate crystallographic studies under non-ambient conditions are available as well as a number of options for automation. An indication of the scope of the science carried out on the beamline is provided by the range of highlights selected for this paper.

  6. Influence of modulation method on using LC-traps with single-phase voltage source converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Min, Huang; Bai, Haofeng

    2015-01-01

    The switching-frequency LC-trap filter has recently been employed with high-order passive filters for Voltage Source Inverters (VSIs). This paper investigates the influence of modulation method on using the LC-traps with single-phase VSIs. Two-level (bipolar) and three-level (unipolar) modulations...... that include phase distortion and alternative phase opposition distortion methods are analyzed. Harmonic filtering performances of four LC-trap-based filters with different locations of LC-traps are compared. It is shown that the use of parallel-LC-traps in series with filter inductors, either grid...... or converter side, has a worse harmonic filtering performance than using series-LC-trap in the shunt branch. Simulations and experimental results are presented for verifications....

  7. Formation of Micro and Mesoporous Amorphous Silica-Based Materials from Single Source Precursors

    Directory of Open Access Journals (Sweden)

    Mohd Nazri Mohd Sokri

    2016-03-01

    Full Text Available Polysilazanes functionalized with alkoxy groups were designed and synthesized as single source precursors for fabrication of micro and mesoporous amorphous silica-based materials. The pyrolytic behaviors during the polymer to ceramic conversion were studied by the simultaneous thermogravimetry-mass spectrometry (TG-MS analysis. The porosity of the resulting ceramics was characterized by the N2 adsorption/desorption isotherm measurements. The Fourier transform infrared spectroscopy (FT-IR and Raman spectroscopic analyses as well as elemental composition analysis were performed on the polymer-derived amorphous silica-based materials, and the role of the alkoxy group as a sacrificial template for the micro and mesopore formations was discussed from a viewpoint to establish novel micro and mesoporous structure controlling technologies through the polymer-derived ceramics (PDCs route.

  8. Source apportionment of single aerosol particles in the atmosphere of Shanghai city

    International Nuclear Information System (INIS)

    Qiu Zhijun; Lu Rongrong; Guo Panlin; Wang Jiqing; Qiu Huiyuan; Li Xiaolin; Zhu Jieqing

    2001-01-01

    A nuclear microprobe with high spatial resolution and high analytical sensitivity was applied to analyze atmospheric aerosol at five monitoring sites in Shanghai city. Meantime, a new pattern recognition technique, which used the micro-PIXE spectrum of a single aerosol particle as its fingerprint, was developed to identify the origin of the particle. The results showed that the major contributors to the atmosphere pollution were soil dust (31.6%), building dust (30.8%), and the next were vehicle exhaust (13.7%), metallurgic industry excrements (5.6%), oil combustion (5%) and coal combustion (2.3%). Besides these, about 10% of the particles could not be identified. Based on the cluster analysis of these particles, they could be divided into soil dust, building dust and metallurgic industry excrements. Moreover, some new pollution sources from tyres and chemical plants were also revealed

  9. Spectrally resolved single-shot wavefront sensing of broadband high-harmonic sources

    Science.gov (United States)

    Freisem, L.; Jansen, G. S. M.; Rudolf, D.; Eikema, K. S. E.; Witte, S.

    2018-03-01

    Wavefront sensors are an important tool to characterize coherent beams of extreme ultraviolet radiation. However, conventional Hartmann-type sensors do not allow for independent wavefront characterization of different spectral components that may be present in a beam, which limits their applicability for intrinsically broadband high-harmonic generation (HHG) sources. Here we introduce a wavefront sensor that measures the wavefronts of all the harmonics in a HHG beam in a single camera exposure. By replacing the mask apertures with transmission gratings at different orientations, we simultaneously detect harmonic wavefronts and spectra, and obtain sensitivity to spatiotemporal structure such as pulse front tilt as well. We demonstrate the capabilities of the sensor through a parallel measurement of the wavefronts of 9 harmonics in a wavelength range between 25 and 49 nm, with up to lambda/32 precision.

  10. Steps towards single source--collecting data about quality of life within clinical information systems.

    Science.gov (United States)

    Fritz, Fleur; Ständer, Sonja; Breil, Bernhard; Dugas, Martin

    2010-01-01

    Information about the quality of life from patients being treated in routine medical care is important for the attending physician. This data is also needed in research for example to evaluate the therapy and the course of the disease respectively. Especially skin diseases often negatively affect the quality of life. Therefore we aimed to design a concept to collect such data during treatment and use it for both medical care and research in the setting of dermatology. We performed a workflow analysis and implemented a designated form using the tools of the local clinical information system. Quality of life data is now collected within the clinical information system during treatment and is used for discharge letters, progress overviews as well as research about the treatment and course of disease. This concept which contributes to the single source approach was feasible within dermatology and is ready to be expanded into other domains.

  11. Prograph Based Analysis of Single Source Shortest Path Problem with Few Distinct Positive Lengths

    Directory of Open Access Journals (Sweden)

    B. Bhowmik

    2011-08-01

    Full Text Available In this paper we propose an experimental study model S3P2 of a fast fully dynamic programming algorithm design technique in finite directed graphs with few distinct nonnegative real edge weights. The Bellman-Ford’s approach for shortest path problems has come out in various implementations. In this paper the approach once again is re-investigated with adjacency matrix selection in associate least running time. The model tests proposed algorithm against arbitrarily but positive valued weighted digraphs introducing notion of Prograph that speeds up finding the shortest path over previous implementations. Our experiments have established abstract results with the intention that the proposed algorithm can consistently dominate other existing algorithms for Single Source Shortest Path Problems. A comparison study is also shown among Dijkstra’s algorithm, Bellman-Ford algorithm, and our algorithm.

  12. Choosing a Better Delay Line Medium between Single-Mode and Multi-Mode Optical Fibers: the Effect of Bending

    Directory of Open Access Journals (Sweden)

    Auwal Mustapha Imam

    2017-12-01

    Full Text Available Optical fiber cables are materials whose core is made of silica and other materials such as chalcogenide glasses; they transmit a digital signal via light pulses through an extremely thin strand of glass. The light propagates and is being guided by the core which is surrounded by the cladding. Light travels in the optical fiber in the form of total internal reflection in the core of the fibers. The flexibility, low tensile strength, low signal loss, high bandwidth and other characteristics of optical fibers favors it for use as a delay medium in many applications. Another favorable characteristic of optical fiber delay lines is are their relative insensitivities to environmental effects and electromagnetic interferences. The immunity of optical fibers to interferences and their less weight added advantages to it for use as delay medium. Single-mode and multi-mode are the two most popular types of optical fibers. Single-mode fibers have good propagation and delay properties with a minimal loss that allows the signal to propagate in a large distance with insignificant distortion or attenuation. The percentage of power transmission of single-mode fibers is found to be higher than that of the multi-mode fibers. It is, therefore, a preferred type for use as a delay line. In this paper, relative studies of the two optical fibers modes, and the results of power input/output measurement of the two modes are presented with a view to coming up with a better type for use as a delay medium.

  13. Sources of stem rust resistance in wheat-alien introgression lines

    Science.gov (United States)

    Stem rust, caused by Puccinia graminis f. sp. tritici, is one of the most devastating diseases of wheat and the novel highly virulent race of TTKSK and its lineage are threatening wheat production worldwide. The objective of the study was to identify new sources of resistance in wheat-alien introgre...

  14. The role of on-line communication in open source software development

    DEFF Research Database (Denmark)

    Vujovic, S.; Ulhøi, John Parm

    2004-01-01

    allow parallel development and dynamic online exchanges during the overall innovation process. In conceptualizing online computer-based innovation process in the form of Open Source Software, the paper will borrow from theory on networks and communities of practice, which take into account social...

  15. Wave propagation speeds and source term influences in single and integral porosity shallow water equations

    Directory of Open Access Journals (Sweden)

    Ilhan Özgen

    2017-10-01

    Full Text Available In urban flood modeling, so-called porosity shallow water equations (PSWEs, which conceptually account for unresolved structures, e.g., buildings, are a promising approach to addressing high CPU times associated with state-of-the-art explicit numerical methods. The PSWE can be formulated with a single porosity term, referred to as the single porosity shallow water model (SP model, which accounts for both the reduced storage in the cell and the reduced conveyance, or with two porosity terms: one accounting for the reduced storage in the cell and another accounting for the reduced conveyance. The latter form is referred to as an integral or anisotropic porosity shallow water model (AP model. The aim of this study was to analyze the differences in wave propagation speeds of the SP model and the AP model and the implications of numerical model results. First, augmented Roe-type solutions were used to assess the influence of the source terms appearing in both models. It is shown that different source terms have different influences on the stability of the models. Second, four computational test cases were presented and the numerical models were compared. It is observed in the eigenvalue-based analysis as well as in the computational test cases that the models converge if the conveyance porosity in the AP model is close to the storage porosity. If the porosity values differ significantly, the AP model yields different wave propagation speeds and numerical fluxes from those of the BP model. In this study, the ratio between the conveyance and storage porosities was determined to be the most significant parameter.

  16. An improved fault detection classification and location scheme based on wavelet transform and artificial neural network for six phase transmission line using single end data only.

    Science.gov (United States)

    Koley, Ebha; Verma, Khushaboo; Ghosh, Subhojit

    2015-01-01

    Restrictions on right of way and increasing power demand has boosted development of six phase transmission. It offers a viable alternative for transmitting more power, without major modification in existing structure of three phase double circuit transmission system. Inspite of the advantages, low acceptance of six phase system is attributed to the unavailability of a proper protection scheme. The complexity arising from large number of possible faults in six phase lines makes the protection quite challenging. The proposed work presents a hybrid wavelet transform and modular artificial neural network based fault detector, classifier and locator for six phase lines using single end data only. The standard deviation of the approximate coefficients of voltage and current signals obtained using discrete wavelet transform are applied as input to the modular artificial neural network for fault classification and location. The proposed scheme has been tested for all 120 types of shunt faults with variation in location, fault resistance, fault inception angles. The variation in power system parameters viz. short circuit capacity of the source and its X/R ratio, voltage, frequency and CT saturation has also been investigated. The result confirms the effectiveness and reliability of the proposed protection scheme which makes it ideal for real time implementation.

  17. An on-line dilution system for spectrometry using an inductively coupled plasma source

    International Nuclear Information System (INIS)

    Moore, G.L.; Watson, A.E.; Humphries-Cuff, P.J.

    1982-01-01

    An on-line dilution system that uses a two-channel peristaltic pump to feed a GMK Babington type of nebulizer is described. By the use of a diluent containing the appropriate concentrations of acid, sodium, and internal standard element, which was fed at a constant rate to the nebulizer, the system produced analytical results that are not significantly different (less than 3 per cent relative) from those obtained with the normal dilution technique. However, a considerable saving in time is achieved, as well as a saving in the use of expensive reagents

  18. Systematic search for spherical crystal X-ray microscopes matching 1-25 keV spectral line sources.

    Science.gov (United States)

    Schollmeier, Marius S; Loisel, Guillaume P

    2016-12-01

    Spherical-crystal microscopes are used as high-resolution imaging devices for monochromatic x-ray radiography or for imaging the source itself. Crystals and Miller indices (hkl) have to be matched such that the resulting lattice spacing d is close to half the spectral wavelength used for imaging, to fulfill the Bragg equation with a Bragg angle near 90 ∘ which reduces astigmatism. Only a few suitable crystal and spectral-line combinations have been identified for applications in the literature, suggesting that x-ray imaging using spherical crystals is constrained to a few chance matches. In this article, after performing a systematic, automated search over more than 9 × 10 6 possible combinations for x-ray energies between 1 and 25 keV, for six crystals with arbitrary Miller-index combinations hkl between 0 and 20, we show that a matching, efficient crystal and spectral-line pair can be found for almost every He α or K α x-ray source for the elements Ne to Sn. Using the data presented here it should be possible to find a suitable imaging combination using an x-ray source that is specifically selected for a particular purpose, instead of relying on the limited number of existing crystal imaging systems that have been identified to date.

  19. Interactions and effects of BSA-functionalized single-walled carbon nanotubes on different cell lines

    Science.gov (United States)

    Muzi, Laura; Tardani, Franco; La Mesa, Camillo; Bonincontro, Adalberto; Bianco, Alberto; Risuleo, Gianfranco

    2016-04-01

    Functionalized carbon nanotubes (CNTs) have shown great promise in several biomedical contexts, spanning from drug delivery to tissue regeneration. Thanks to their unique size-related properties, single-walled CNTs (SWCNTs) are particularly interesting in these fields. However, their use in nanomedicine requires a clear demonstration of their safety in terms of tissue damage, toxicity and pro-inflammatory response. Thus, a better understanding of the cytotoxicity mechanisms, the cellular interactions and the effects that these materials have on cell survival and on biological membranes is an important first step for an appropriate assessment of their biocompatibility. In this study we show how bovine serum albumin (BSA) is able to generate homogeneous and stable dispersions of SWCNTs (BSA-CNTs), suggesting their possible use in the biomedical field. On the other hand, this study wishes to shed more light on the impact and the interactions of protein-stabilized SWCNTs with two different cell types exploiting multidisciplinary techniques. We show that BSA-CNTs are efficiently taken up by cells. We also attempt to describe the effect that the interaction with cells has on the dielectric characteristics of the plasma membrane and ion flux using electrorotation. We then focus on the BSA-CNTs’ acute toxicity using different cellular models. The novel aspect of this work is the evaluation of the membrane alterations that have been poorly investigated to date.

  20. 77 FR 30294 - Award of a Single Source Cooperative Agreement Grant to the Congressional Hunger Center in...

    Science.gov (United States)

    2012-05-22

    ... no individual in ACF designated to work specifically on these nutrition- and hunger-related issues... Source Cooperative Agreement Grant to the Congressional Hunger Center in Washington, DC AGENCY: Office of...) announces the award of a single source cooperative agreement to the Congressional Hunger Center in...

  1. Space Vector Pulse Width Modulation Strategy for Single-Phase Three-Level CIC T-source Inverter

    DEFF Research Database (Denmark)

    Shults, Tatiana E.; Husev, Oleksandr O.; Blaabjerg, Frede

    2016-01-01

    This paper presents a novel space vector pulse-width modulation strategy for a single-phase three-level buck-boost inverter based on an impedance-source network. The case study system is based on T-source inverter with continuous input current. To demonstrate the improved performance of the inver...

  2. Single-phase AutoReClosure ARC failure on 400 kV combinedcable/overhead line with permanently connected shunt reactor

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Søgaard, Kim

    2008-01-01

    consisting of overhead lines, crossbonded cable sections and shunt reactor has been created in PSCAD/EMTDC and verified against measurements with good results. Main focus has been put on the likelihood of having a successful single-phase autoreclosure ARC in such a combined cable/OHL line....

  3. High step-up isolated efficient single switch DC-DC converter for renewable energy source

    Directory of Open Access Journals (Sweden)

    A. Gopi

    2014-12-01

    Full Text Available In this paper, an isolated high step-up single switch DC-DC converter for renewable energy source is proposed. In the proposed converter high step-up voltage is obtained by single power switching technique that operates low duty cycle with isolated transformer inductors and switched capacitors and power diodes. The disadvantage of conventional converters is that it has high duty ratio and high voltage stress on power devices with less efficiency. The proposed converter eliminates the switching losses and recycles the leakage energy which includes reverse recovery energy of the power diode by using passive clamp circuit. To achieve high output voltage gain, the isolated transformer primary terminal and secondary terminal are connected in series during switching operation. PSIM software has been used for simulation. Simulation circuit is analyzed at 40Vdc/400Vdc, 200 W and this operation is validated by implementing in the hardware model at 12Vdc/120Vdc, 60 W.

  4. Optical access network using centralized light source, single-mode fiber + broad wavelength window multimode fiber

    Science.gov (United States)

    Yam, Scott S.-H.; Kim, Jaedon; Gutierrez, David; Achten, Frank

    2006-08-01

    Access networks based on a single-mode fiber (SMF) using a centralized light source (CLS) have attracted much attention recently due to their wavelength management flexibility and potential for cost reduction at customers' premises. Future networks, in addition, are likely to contain segments of multimode fiber (MMF), whose core dimension is relatively large in comparison with its single-mode counterpart, substantially reducing fiber alignment constraints and the subsequent network construction and installation cost. In this study, a CLS-based passive optical network (PON) is proposed, which will use a new generation of high-performance MMF optimized for a broad wavelength transmission window spanning from 1300to1550 nm, with a bandwidth distance product (BDP) of 40 Gbit/s-km. The proposed architecture is implemented in a test bed, and its performance is verified by bit error ratio (BER) measurement. Results show that we can implement high-performance CLS-based PONs containing both an SMF and an MMF infrastructure, simultaneously.

  5. Preliminary study of single contrast enhanced dual energy heart imaging using dual-source CT

    International Nuclear Information System (INIS)

    Peng Jin; Zhang Longjiang; Zhou Changsheng; Lu Guangming; Ma Yan; Gu Haifeng

    2009-01-01

    Objective: To evaluate the feasibility and preliminary applications of single contrast enhanced dual energy heart imaging using dual-source CT (DSCT). Methods: Thirty patients underwent dual energy heart imaging with DSCT, of which 6 cases underwent SPECT or DSA within one week. Two experienced radiologists assessed image quality of coronary arteries and iodine map of myocardium. and correlated the coronary artery stenosis with the perfusion distribution of iodine map. Results: l00% (300/300) segments reached diagnostic standards. The mean score of image for all patients was 4.68±0.57. Mural coronary artery was present in 10 segments in S cases, atherosclerotic plaques in 32 segments in 12 cases, of which 20 segments having ≥50% stenosis, 12 segments ≤50% stenosis; dual energy CT coronary angiography was consistent with the DSA in 3 patients. 37 segmental perfusion abnormalities on iodine map were found in 15 cases, including 28 coronary blood supply segment narrow segment and 9 no coronary stenosis (including three negative segments in SPECD. Conclusion: Single contrast enhanced dual energy heart imaging can provide good coronary artery and myocardium perfusion images in the patients with appropriate heart rate, which has a potential to be used in the clinic and further studies are needed. (authors)

  6. Measurement system of correlation functions of microwave single photon source in real time

    Science.gov (United States)

    Korenkov, A.; Dmitriev, A.; Astafiev, O.

    2018-02-01

    Several quantum setups, such as quantum key distribution networks[1] and quantum simulators (e.g. boson sampling), by their design rely on single photon sources (SPSs). These quantum setups were demonstrated to operate in optical frequency domain. However, following the steady advances in circuit quantum electrodynamics, a proposal has been made recently[2] to demonstrate boson sampling with microwave photons. This in turn requires the development of reliable microwave SPS. It's one of the most important characteristics are the first-order and the second-order correlation functions g1 and g2. The measurement technique of g1 and g2 is significantly different from that in the optical domain [3],[4] because of the current unavailability of microwave single-photon detectors. In particular, due to high levels of noise present in the system a substantial amount of statistics in needed to be acquired. This work presents a platform for measurement of g1 and g2 that processes the incoming data in real time, maximizing the efficiency of data acquisition. The use of field-programmable gate array (FPGA) electronics, common in similar experiments[3] but complex in programming, is avoided; instead, the calculations are performed on a standard desktop computer. The platform is used to perform the measurements of the first-order and the second-order correlation functions of the microwave SPS.

  7. Optically pumped semiconductor lasers: Conception and characterization of a single mode source for Cesium atoms manipulation

    International Nuclear Information System (INIS)

    Cocquelin, B.

    2009-02-01

    Lasers currently used in atomic clocks or inertial sensors are suffering from a lack of power, narrow linewidth or compactness for future spatial missions. Optically pumped semiconductor lasers, which combine the approach of classical solid state lasers and the engineering of semiconductor laser, are considered here as a candidate to a metrological laser source dedicated to the manipulation of Cesium atoms in these instruments. These lasers have demonstrated high power laser emission in a circular single transverse mode, as well as single longitudinal mode emission, favoured by the semiconductor structure and the external cavity design. We study the definition and the characterization of a proper semiconductor structure for the cooling and the detection of Cesium atoms at 852 nm. A compact and robust prototype tunable on the Cesium D2 hyperfine structure is built. The laser frequency is locked to an atomic transition thanks to a saturated absorption setup. The emission spectral properties are investigated, with a particular attention to the laser frequency noise and the laser linewidth. Finally, we describe and model the thermal properties of the semiconductor structure, which enables the simulation of the laser power characteristic. The experimental parameters are optimised to obtain the maximum output power with our structure. Thanks to our analysis, we propose several ways to overcome these limitations, by reducing the structure heating. (authors)

  8. Multiframe, Single Line-of-Sight X-Ray Imager for Burning Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Kevin L. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-01-28

    The purpose of this LDRD project was to demonstrate high spatial and temporal resolution x-ray imaging using optical detectors, and in particular the VISAR and OHRV diagnostics on the OMEGA laser. The x-ray source being imaged was a backlighter capsule being imploded by 39 beams of the OMEGA laser. In particular this approach utilized a semiconductor with the side facing the backlighter capsule coated with a thin aluminum layer to allow x rays to pass through the metal layer and then get absorbed in the semiconductor. The other side of the semiconductor was AR coated to allow the VISAR or OHRV probe beam to sample the phase change of the semiconductor as the x rays were absorbed in the semiconductor. This technique is capable of acquiring sub-picosecond 2-D or 1-D x-ray images, detector spatial resolution of better than 10 um and the ability to operate in a high neutron flux environment expected on ignition shots with burning plasmas. In addition to demonstrating this technique on the OMEGA laser, several designs were made to improve the phase sensitivity, temporal resolution and number of frames over the existing diagnostics currently implemented on the OMEGA laser. These designs included both 2-d imaging diagnostics as well as improved 1-D imaging diagnostics which were streaked in time.

  9. Single-event burnout hardening of planar power MOSFET with partially widened trench source

    Science.gov (United States)

    Lu, Jiang; Liu, Hainan; Cai, Xiaowu; Luo, Jiajun; Li, Bo; Li, Binhong; Wang, Lixin; Han, Zhengsheng

    2018-03-01

    We present a single-event burnout (SEB) hardened planar power MOSFET with partially widened trench sources by three-dimensional (3D) numerical simulation. The advantage of the proposed structure is that the work of the parasitic bipolar transistor inherited in the power MOSFET is suppressed effectively due to the elimination of the most sensitive region (P-well region below the N+ source). The simulation result shows that the proposed structure can enhance the SEB survivability significantly. The critical value of linear energy transfer (LET), which indicates the maximum deposited energy on the device without SEB behavior, increases from 0.06 to 0.7 pC/μm. The SEB threshold voltage increases to 120 V, which is 80% of the rated breakdown voltage. Meanwhile, the main parameter characteristics of the proposed structure remain similar with those of the conventional planar structure. Therefore, this structure offers a potential optimization path to planar power MOSFET with high SEB survivability for space and atmospheric applications. Project supported by the National Natural Science Foundation of China (Nos. 61404161, 61404068, 61404169).

  10. Development of high resolution vacuum ultraviolet beam line at Indus-1 synchrotron source

    International Nuclear Information System (INIS)

    Shukla, R.P.; Das, N.C.; Udupa, D.V.; Saraswathy, P.; Sunanda, K.; Jha, S.N.; Shastri, Aparna; Singh, Paramjeet; Mallick, Manika; Mishra, A.P.; Sahoo, N.K.; Sinha, A.K.; Bhatt, S.; Sahni, V.C.

    2005-07-01

    High resolution vacuum ultraviolet beamline at Indus-1 450 MeV synchrotron source has been developed for carrying out absorption spectral studies of atoms and molecules. The beamline consists of three major parts i.e. a focusing optical system, an absorption cell and a high resolution 6.65 m vacuum ultraviolet spectrometer in Eagle mount. The wavelength range of the spectrometer is from 700 A to 2000 A and the resolution of the spectrometer is 0.01 A. Using the synchrotron source Indus-1, the absorption spectra of oxygen, ammonia and carbon disulphide have been recorded at the wavelength band of 1750 A, 1881 A and 3100 A respectively. Details of different aspects of design and development of the high resolution VUV beamline are described in this report. (author)

  11. Efficient fiber-coupled single-photon source based on quantum dots in a photonic-crystal waveguide

    DEFF Research Database (Denmark)

    Daveau, Raphaël S.; Balram, Krishna C.; Pregnolato, Tommaso

    2017-01-01

    Many photonic quantum information processing applications would benefit from a high brightness, fiber-coupled source of triggered single photons. Here, we present a fiber-coupled photonic-crystal waveguide (PCWG) singlephoton source relying on evanescent coupling of the light field from a tapered...... transfer it to the fiber. The applied outcoupling method is robust, stable over time, and broadband over several tens of nanometers, which makes it a highly promising pathway to increase the efficiency and reliability of planar chip-based single-photon sources....

  12. Seeing-limited radial velocity field mapping of extended emission line sources using a new imaging Fabry-Perot system

    International Nuclear Information System (INIS)

    Tayler, K.; Atherton, P.D.

    1980-01-01

    TAURUS, a new Fabry-Perot imaging device, designed to obtain complete seeing-limited radial velocity field maps of extended emission-line sources, is described. A servo-controlled Fabry-Perot is used with a focal reducer and a two-dimensional photon-counting (area detector) system, to obtain the velocity information. The system has been fully tested and the first observations of the highly complex velocity field of the irregular galaxy, M82, are used to illustrate the power of the instrument. (author)

  13. Program scheme using common source lines in channel stacked NAND flash memory with layer selection by multilevel operation

    Science.gov (United States)

    Kim, Do-Bin; Kwon, Dae Woong; Kim, Seunghyun; Lee, Sang-Ho; Park, Byung-Gook

    2018-02-01

    To obtain high channel boosting potential and reduce a program disturbance in channel stacked NAND flash memory with layer selection by multilevel (LSM) operation, a new program scheme using boosted common source line (CSL) is proposed. The proposed scheme can be achieved by applying proper bias to each layer through its own CSL. Technology computer-aided design (TCAD) simulations are performed to verify the validity of the new method in LSM. Through TCAD simulation, it is revealed that the program disturbance characteristics is effectively improved by the proposed scheme.

  14. Single Sources in the Low-Frequency Gravitational Wave Sky:properties and time to detection by pulsar timing arrays

    Science.gov (United States)

    Kelley, Luke Zoltan; Blecha, Laura; Hernquist, Lars; Sesana, Alberto; Taylor, Stephen R.

    2018-03-01

    We calculate the properties, occurrence rates and detection prospects of individually resolvable `single sources' in the low frequency gravitational wave (GW) spectrum. Our simulations use the population of galaxies and massive black hole binaries from the Illustris cosmological hydrodynamic simulations, coupled to comprehensive semi-analytic models of the binary merger process. Using mock pulsar timing arrays (PTA) with, for the first time, varying red-noise models, we calculate plausible detection prospects for GW single sources and the stochastic GW background (GWB). Contrary to previous results, we find that single sources are at least as detectable as the GW background. Using mock PTA, we find that these `foreground' sources (also `deterministic'/`continuous') are likely to be detected with ˜ 20 yr total observing baselines. Detection prospects, and indeed the overall properties of single sources, are only moderately sensitive to binary evolution parameters—namely eccentricity & environmental coupling, which can lead to differences of ˜ 5 yr in times to detection. Red noise has a stronger effect, roughly doubling the time to detection of the foreground between a white-noise only model (˜ 10 - 15 yr) and severe red noise (˜20 - 30 yr). The effect of red noise on the GWB is even stronger, suggesting that single source detections may be more robust. We find that typical signal-to-noise ratios for the foreground peak near f = 0.1 yr-1, and are much less sensitive to the continued addition of new pulsars to PTA.

  15. Identification of Single Nucleotide Polymorphisms and analysis of Linkage Disequilibrium in sunflower elite inbred lines using the candidate gene approach

    Directory of Open Access Journals (Sweden)

    Heinz Ruth A

    2008-01-01

    Full Text Available Abstract Background Association analysis is a powerful tool to identify gene loci that may contribute to phenotypic variation. This includes the estimation of nucleotide diversity, the assessment of linkage disequilibrium structure (LD and the evaluation of selection processes. Trait mapping by allele association requires a high-density map, which could be obtained by the addition of Single Nucleotide Polymorphisms (SNPs and short insertion and/or deletions (indels to SSR and AFLP genetic maps. Nucleotide diversity analysis of randomly selected candidate regions is a promising approach for the success of association analysis and fine mapping in the sunflower genome. Moreover, knowledge of the distance over which LD persists, in agronomically meaningful sunflower accessions, is important to establish the density of markers and the experimental design for association analysis. Results A set of 28 candidate genes related to biotic and abiotic stresses were studied in 19 sunflower inbred lines. A total of 14,348 bp of sequence alignment was analyzed per individual. In average, 1 SNP was found per 69 nucleotides and 38 indels were identified in the complete data set. The mean nucleotide polymorphism was moderate (θ = 0.0056, as expected for inbred materials. The number of haplotypes per region ranged from 1 to 9 (mean = 3.54 ± 1.88. Model-based population structure analysis allowed detection of admixed individuals within the set of accessions examined. Two putative gene pools were identified (G1 and G2, with a large proportion of the inbred lines being assigned to one of them (G1. Consistent with the absence of population sub-structuring, LD for G1 decayed more rapidly (r2 = 0.48 at 643 bp; trend line, pooled data than the LD trend line for the entire set of 19 individuals (r2 = 0.64 for the same distance. Conclusion Knowledge about the patterns of diversity and the genetic relationships between breeding materials could be an invaluable aid in crop

  16. Source of single photons and interferometry with one photon. From the Young's slit experiment to the delayed choice

    International Nuclear Information System (INIS)

    Jacques, V.

    2007-11-01

    This manuscript is divided in two independent parts. In the first part, we study the wave-particle duality for a single photon emitted by the triggered photoluminescence of a single NV color center in a diamond nano-crystal. We first present the realization of a single-photon interference experiment using a Fresnel's bi-prism, in a scheme equivalent to the standard Young's double-slit textbook experiment. We then discuss the complementarity between interference and which-path information in this two-path interferometer. We finally describe the experimental realization of Wheeler's delayed-choice Gedanken experiment, which is a fascinating and subtle illustration of wave-particle duality. The second part of the manuscript is devoted to the efficiency improvement of single-photon sources. We first describe the implementation of a new single-photon source based on the photoluminescence of a single nickel-related defect center in diamond. The photophysical properties of such defect make this single-photon source well adapted to open-air quantum cryptography. We finally demonstrate an original method that leads to an improvement of single-molecule photo stability at room temperature. (author)

  17. On-line Field Measurements of Speciated PM1 Emission Factors from Common South Asian Combustion Sources

    Science.gov (United States)

    DeCarlo, P. F.; Goetz, J. D.; Giordano, M.; Stockwell, C.; Maharjan, R.; Adhikari, S.; Bhave, P.; Praveen, P. S.; Panday, A. K.; Jayarathne, T. S.; Stone, E. A.; Yokelson, R. J.

    2017-12-01

    Characterization of aerosol emissions from prevalent but under sampled combustion sources in South Asia was performed as part of the Nepal Ambient Monitoring and Source Testing Experiment (NAMaSTE) in April 2015. Targeted emission sources included cooking stoves with a variety of solid fuels, brick kilns, garbage burning, crop-residue burning, diesel irrigation pumps, and motorcycles. Real-time measurements of submicron non-refractory particulate mass concentration and composition were obtained using an Aerodyne mini Aerosol Mass Spectrometer (mAMS). Speciated PM1 mass emission factors were calculated for all particulate species (e.g. organics, sulfates, nitrates, chlorides, ammonium) and for each source type using the carbon mass balance approach. Size resolved emission factors were also acquired using a novel high duty cycle particle time-of-flight technique (ePTOF). Black carbon and brown carbon absorption emission factors and absorption Angström exponents were measured using filter loading and scattering corrected attenuation at 370 nm and 880 nm with a dual spot aethalometer (Magee Scientific AE-33). The results indicate that open garbage burning is a strong emitter of organic aerosol, black carbon, and internally mixed particle phase hydrogen chloride (HCl). Emissions of HCl were attributed to the presence chlorinated plastics. The primarily coal fired brick kilns were found to be large emitters of sulfate but large differences in the organic and light absorbing component of emissions were observed between the two kiln types investigated (technologically advanced vs. traditional). These results, among others, bring on-line and field-tested aerosol emission measurements to an area of atmoshperic research dominated by off-line or laboratory based measurements.

  18. Childhood brain tumor occurrence in relation to external power lines and other sources of residential magnetic fields. Final report

    International Nuclear Information System (INIS)

    Gurney, J.G.; Mueller, B.A.; Davis, S.

    1995-10-01

    A population-based case-control study of incident brain tumors was conducted in the Seattle area among children younger than 20 years, diagnosed from 1984-1990; mothers of 133 cases and 270 controls participated. The relation between childhood brain tumor occurrence and exposure to potential sources of residential magnetic fields was assessed, focusing on whether proximity to high-current residential power lines or use of electric appliances or electric heating sources by the mother while pregnant or by the child before diagnosis, were associated with increased risks of brain tumor occurrence. For the 120 cases and 240 controls, risk of brain tumor occurrence did not increase with increasing magnetic field exposure as indicated by the 5-level Wertheimer-Leeper (W-L) code. Relative to those with underground wiring, the odds ratios for increasing exposure levels were: very low current configuration, 1.3; ordinary low current configuration, 0.7; ordinary high-current configuration, 1.1; and very high current configuration, 0.5. When exposure was dichotomized as high versus low, the odds ratio was 0.9 (95% CI 0.5-1.5) and did not vary significantly. When the analysis was restricted to the 96 subjects known to live in only one home, the odds ratio was 1.1. The distributions of the 5-level W-L code were similar between study participants and non-respondents, and odds ratios were not appreciably changed when non-respondents were included in the analysis. No elevations in risk were found for ever-versus-never use of electric blankets, water beds, or electric heating sources. Odds ratios were slightly elevated for nine appliances and were at or below 1.0 for eight others. These data do not support the hypothesis that exposure to magnetic fields from high-current power lines, electric heating sources, or electric appliances, is associated with the subsequent occurrence of brain tumors in children

  19. Focusing and imaging sharp line x-ray and gamma-ray sources using variable-metric diffraction crystals

    International Nuclear Information System (INIS)

    Smither, R.K.

    1982-01-01

    A new method has been devised for focusing and imaging the radiation from sharp-line sources of x-rays and gamma-rays, which makes use of variable-metric diffraction crystals. A variable-metric diffraction crystal is one in which the spacings between the crystalline planes is varied as a function of position in the crystal by either the application of a thermal gradient or by changing the composition of a two component or multiple component crystal. This change in planar spacing changes the Bragg diffraction angle for monochromatic radiation as a function of position in the crystal and makes it possible to obtain focusing and in some cases imaging of a sharp-line point source or parallel beam source. This new approach to focusing x-rays and gamma-rays is used to design a number of gamma ray telescopes suitable for focusing the 511 keV annihilation radiation from the strong source of the center of our galaxy. The new designs are surprisingly efficient with approximately 20% of the radiation incident on the variable-metric diffraction crystals being focused on the image spot. Crystals of Ge, Ge + Si, Si, and quartz are used with mosaic widths of 10 arc sec. The size of the telescope can be scaled up or down without affecting the angular resolution or the energy resolution. The largest model described is 50 m long and has 10 crystal diffraction ring assembles with radii between 71 and 200 cm. The total area of the diffraction crystal is 24,610 cm 2 and the effective area (total x diffraction coefficient x transmission) is 4745 cm 2 . An example of a smaller telescope is also given that is only 12.5 m long and has an effective area of 297 cm 2

  20. Performance enhancement of the single-phase series active filter by employing the load voltage waveform reconstruction and line current sampling delay reduction methods

    DEFF Research Database (Denmark)

    Senturk, O.S.; Hava, A.M.

    2011-01-01

    This paper proposes the waveform reconstruction method (WRM), which is utilized in the single-phase series active filter's (SAF's) control algorithm, in order to extract the load harmonic voltage component of voltage harmonic type single-phase diode rectifier loads. Employing WRM and the line...

  1. Picosecond wide-field time-correlated single photon counting fluorescence microscopy with a delay line anode detector

    Energy Technology Data Exchange (ETDEWEB)

    Hirvonen, Liisa M.; Le Marois, Alix; Suhling, Klaus, E-mail: klaus.suhling@kcl.ac.uk [Department of Physics, King' s College London, Strand, London WC2R 2LS (United Kingdom); Becker, Wolfgang; Smietana, Stefan [Becker & Hickl GmbH, Nahmitzer Damm 30, 12277 Berlin (Germany); Milnes, James; Conneely, Thomas [Photek Ltd., 26 Castleham Rd, Saint Leonards-on-Sea TN38 9NS (United Kingdom); Jagutzki, Ottmar [Institut für Kernphysik, Max-von-Laue-Str. 1, 60438 Frankfurt (Germany)

    2016-08-15

    We perform wide-field time-correlated single photon counting-based fluorescence lifetime imaging (FLIM) with a crossed delay line anode image intensifier, where the pulse propagation time yields the photon position. This microchannel plate-based detector was read out with conventional fast timing electronics and mounted on a fluorescence microscope with total internal reflection (TIR) illumination. The picosecond time resolution of this detection system combines low illumination intensity of microwatts with wide-field data collection. This is ideal for fluorescence lifetime imaging of cell membranes using TIR. We show that fluorescence lifetime images of living HeLa cells stained with membrane dye di-4-ANEPPDHQ exhibit a reduced lifetime near the coverslip in TIR compared to epifluorescence FLIM.

  2. On-line study of growth kinetics of single hyphae of Aspergillus oryzae in a flow-through cell

    DEFF Research Database (Denmark)

    Christiansen, Torben; Spohr, Anders Bendsen; Nielsen, Jens Bredal

    1999-01-01

    Using image analysis the growth kinetics of the single hyphae of the filamentous fungus Aspergillus oryzae has been determined on-line in a flow-through cell at different glucose concentrations in the range from 26 mg L-1 to 20 g L-1. The tip extension rate of the individual hyphae can be described...... with saturation type kinetics with respect to the length of the hyphae. The maximum tip extension rate is constant for all hyphae measured at the same glucose concentration, whereas the saturation constant for the hyphae varies significantly between the hyphae even within the same hyphal element. When apical...... branching occurs, it is observed that the tip extension rate decreases temporarily. The number of branches formed on a hypha is proportional to the length of the hypha that exceeds a certain minimum length required to support the growth of a new branch. The observed kinetics has been used to simulate...

  3. Validity and reliability of the single-trial line drill test of anaerobic power in basketball players.

    Science.gov (United States)

    Fatouros, I G; Laparidis, K; Kambas, A; Chatzinikolaou, A; Techlikidou, E; Katrabasas, I; Douroudos, I; Leontsini, D; Berberidou, F; Draganidis, D; Christoforidis, C; Tsoukas, D; Kelis, S; Taxildaris, K

    2011-03-01

    This study evaluated the validity, reliability, and sensitivity of the single-trial line drill test (SLDT) for anaerobic power assessment. Twenty-four volunteers were assigned to either a control (C, N.=12) or an experimental (BP, N.=12 basketball players) group. SLDT's (time-to-complete) concurrent validity was evaluated against the Wingate testing (WAnT: mean [MP] and peak power [PP]) and a 30-sec vertical jump testing test (VJT: mean height and MP). Blood lactate concentration was measured at rest and immediately post-test. SLDT's reliability [test-retest intraclass correlation coefficients (ICC), coefficient of variation (CV), Bland-Altman plots] and sensitivity were determined (one-way ANOVA). Kendall's tau correlation analysis revealed correlations (Pbasketball players.

  4. A directly cooled grating substrate for ALS [Advanced Light Source] undulator beam lines

    International Nuclear Information System (INIS)

    DiGennaro, R.; Swain, T.

    1989-08-01

    Design analyses using finite element methods are presented for thermal distortion of water-cooled diffraction grating substrates for a potential application at the LBL Advanced Light Source, demonstrating that refinements in cooling channel configuration and heat flux distribution can significantly reduce optical surface distortion with high heat loads. Using an existing grating substrate design, sensitivity of tangential slope errors due to thermal distortion is evaluated for a variety of thermal boundary conditions, including coolant flow rate and heat transfer film coefficients, surface illumination area and heat distribution profile, and location of the convection cooling surfaces adjacent to the heated region. 1 ref., 5 figs., 2 tabs

  5. A rational approach to enhancing antibody Fc homodimer formation for robust production of antibody mixture in a single cell line.

    Science.gov (United States)

    Yu, Jie; Wang, Xiaoxiao; Xu, Tao; Jin, Qiuheng; Duan, Jinyuan; Wu, Jie; Wu, Haiyan; Xu, Ting; Ye, Sheng

    2017-10-27

    Combinations of different antibodies have been shown to be more effective for managing certain diseases than monotherapy. Co-expression of the antibody mixture in a single cell line is key to reducing complexity during antibody development and manufacturing. However, co-transfection of multiple light and heavy chains into cells often leads to production of mismatched, heterodimeric by-products that are inactive, making the development of co-expression systems that robustly and efficiently produce highly active antibody mixtures a high priority. In this study, we modified the CH3 domain interface of the antibody fragment crystallizable (Fc) region by changing several charge pairs to create electrostatic interactions favoring Fc homodimer formation and disfavoring Fc heterodimer formation. When co-expressed, these modified antibodies with altered charge polarity across the Fc dimer interface preferentially formed homodimers that fully preserved the functions of each component, rather than inactive heterodimers whose formation was reduced because of rationally designed repulsive interactions. We designed eight different combinations and experimentally screened the best one, which enabled us to produce a binary antibody mixture against the EGF receptor with a minimal heterodimer contaminant. We further determined the crystal structure of a triple-mutated Fc variant in the best combination, and we elucidated the molecular interactions favoring Fc homodimer over heterodimer formation, which provided a structural basis for further optimization. The approach presented here demonstrates the feasibility of rational antibody modification for efficient and consistent production of monoclonal antibody mixtures in a single cell line and thus broadens our options for manufacturing more effective antibody-based therapeutic agents. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  6. Rituximab for the first-line maintenance treatment of follicular non-Hodgkin's lymphoma : a NICE single technology appraisal.

    Science.gov (United States)

    Greenhalgh, Janette; Bagust, Adrian; Boland, Angela; Blundell, Michaela; Oyee, James; Beale, Sophie; Dundar, Yenal; Hockenhull, Juliet; Proudlove, Chris; Chu, Patrick

    2013-05-01

    The National Institute for Health and Clinical Excellence (NICE) invited the manufacturer of rituximab (RTX) [Roche] to submit evidence for the clinical and cost effectiveness of RTX as first-line maintenance treatment for patients with follicular non-Hodgkin's lymphoma (fNHL) whose disease has responded to induction therapy with RTX plus cytotoxic chemotherapy (R-CTX) in accordance with the Institute's Single Technology Appraisal (STA) process. The Liverpool Reviews and Implementation Group (LRiG) at the University of Liverpool was commissioned to act as the Evidence Review Group (ERG). This article summarizes the ERG's review of the evidence submitted by the manufacturer and provides a summary of the Appraisal Committee's (AC) decision. The clinical evidence was derived from a multi-centred, open-label, randomized phase III study (PRIMA) comparing first-line maintenance treatment with RTX with observation only in 1,018 patients with previously untreated advanced fNHL. Median time to event (MTE) for the primary endpoint of progression-free survival (PFS) in the RTX arm was not estimable due to data immaturity; median PFS in the observation arm was 48.36 months. A statistically significant benefit of RTX maintenance therapy for PFS was reported (hazard ratio [HR] 0.55, 95 % CI 0.44-0.68; p Markov methodology rather than patient simulations, the impact of patient age on the outcome and the projective PFS modelling. The ERG considered it impossible to draw firm conclusions regarding the clinical or cost effectiveness of the intervention as the dataset was as yet too immature. At a third meeting, the AC concluded that RTX could be recommended as first-line maintenance treatment for patients with fNHL whose disease has responded to induction R-CTX.

  7. A Current-Forced Line-Commutated Inverter for Single-Phase Grid-Connected Photovoltaic Generation Systems

    Directory of Open Access Journals (Sweden)

    UNLU, M.

    2015-05-01

    Full Text Available A simple power electronic interface based on the line-commutated inverter (LCI has been developed in order to inject sinusoidal current to the grid for single-phase grid-connected photovoltaic (PV energy generation systems. The proposed inverter facilitates controlling the injecting/grid current with a controllable power factor in contrast to the conventional LCI system. It is achieved that the total harmonic distortion (THD of the injecting currents for the different firing angles/power factors and reference currents is about 5% or less than 5%. Thus, the grid-connected standards for injecting current are satisfied without filter equipment unlike the conventional LCI system. The proposed system has been built in MATLAB/Simulink and examined experimentally on PV array of 160 W. The simulation and experimental results are better performance than the conventional line-commutated inverter methods reported in the literature. The proposed LCI has a simple and robust structure, and it can be easily synchronized with grid thanks to self-latching property of SCRs. Therefore, it is a good alternative for the power transferring from PV panels to the utility grid in grid-connected PV systems.

  8. Security problems arising from the use of radioactive sources in the study of the wear in refractory linings

    International Nuclear Information System (INIS)

    Courtois, G.; Hours, R.; Le Clerc, P.; Pons, A.

    1960-01-01

    The determination of the wear in refractories is a problem to which these are at present only a few solutions, and these limited or delicate to use. That is the reason why the use of radioactive tracers contained in the refractory has met with rapid success. Unfortunately, the development of the method has been retarded by the need to limit severely the amounts of radioelement incorporated and also by the observation that diffusion of the radioactive product occurred in the refractory. As a result, the limiting amount of 1 mc/500 metric tons of cast-iron has been adopted in France, with the proviso that no single source exceeds 3 mc. Further, we have made special sources with a view to avoiding diffusion phenomena. The essential feature of these sources is that they use pyro-ceramic a non porous material having a high melting point and being, very inert chemically. In these sources, the radioelement can either be entirely encased in the pyro-ceramic or be an integral part of its composition. A comparative study of the two types of sources is actually under way. (author) [fr

  9. CT of small objects with synchrotron radiation from the X-26C beam line at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Spanne, P.; Rivers, M.L.

    1987-01-01

    CT with spatial resolution in the micrometer range has so far not been possible because of the limited photon fluence rates available from conventional x-ray sources. Synchrotron-generated x-rays now make such high-resolution imaging possible. Experiments to develop CT to the micrometer spatial resolution range have been performed at the X-26C microprobe beam line at the National Synchrotron Light Source at Brookhaven National Laboratory. They have so far yielded images with spatial resolutions down to about 20 μm and show that there is a potential to improve the spatial resolution down to at least 1 μm in imaging of dead objects. This creates an entirely new tool for imaging of microstructures in needle biopsies. Calculations shown that the choice of photon energy is critical in minimizing radiation damage and the imaging time. They also show that CT imaging of small laboratory animals, for example, mice and rats, cna be done with a spatial resolution of the order of 50 μm without inducing any significant radiation damage in the animals. By use of a line-shaped x-ray beam, a photodiode array detector, and standard CAMAC acquisition modules, it should be possible to obtain an image in about 1 minute

  10. Fast-grown CdS quantum dots: Single-source precursor approach vs microwave route

    International Nuclear Information System (INIS)

    Fregnaux, Mathieu; Dalmasso, Stéphane; Durand, Pierrick; Zhang, Yudong; Gaumet, Jean-Jacques; Laurenti, Jean-Pierre

    2013-01-01

    A cross-disciplinary protocol of characterization by joint techniques enables one to closely compare chemical and physical properties of CdS quantum dots (QDs) grown by single source precursor methodology (SSPM) or by microwave synthetic route (MWSR). The results are discussed in relation with the synthesis protocols. The QD average sizes, reproducible as a function of the temperatures involved in the growth processes, range complementarily in 2.8–4.5 nm and 4.5–5.2 nm for SSPM and MWSR, respectively. Hexagonal and cubic structures after X-ray diffraction on SSPM and MWSR grown CdS QDs, respectively, are tentatively correlated to a better crystalline quality of the latter with respect to the further ones, suggested by (i) a remarkable stability of the MWSR grown QDs after exposure to air during several days and (ii) no evidence of their fragmentation during mass spectrometry (MS) analyses, after a fair agreement between size dispersities obtained by transmission electron microscopy (TEM) and MS, in contrast with the discrepancy found for the SSPM grown QDs. Correlatively, a better optical quality is suggested for the MWSR grown QDs by the resolution of n > 1 excitonic transitions in their absorption spectra. The QD average sizes obtained by TEM and deduced from MS are in overall agreement. This agreement is improved for the MWSR grown QDs, taking into account a prolate shape of the QDs also observed in the TEM images. For both series of samples, the excitonic responses vs the average sizes are consistent with the commonly admitted empirical energy-size correspondence. A low energy PL band is observed in the case of the SSPM grown QDs. Its decrease in intensity with QD size increase suggests a surface origin tentatively attributed to S vacancies. In the case of the MWSR grown QDs, the absence of this PL is tentatively correlated to an absence of S vacancies and therefore to the stable behavior observed when the QDs are exposed to air. - Highlights: • Single

  11. Efficient Skipping of Single Exon Duplications in DMD Patient-Derived Cell Lines Using an Antisense Oligonucleotide Approach.

    Science.gov (United States)

    Wein, Nicolas; Vulin, Adeline; Findlay, Andrew R; Gumienny, Felecia; Huang, Nianyuan; Wilton, Steve D; Flanigan, Kevin M

    2017-01-01

    Exon skipping strategies in Duchenne muscular dystrophy (DMD) have largely been directed toward altering splicing of exons flanking out-of-frame deletions, with the goal of restoring an open mRNA reading frame that leads to production of an internally deleted but partially functional dystrophin protein. We sought to apply exon skipping to duplication mutations, assuming that the inherently limited efficiency of antisense oligonucleotide-induced exon skipping would more frequently skip a single copy of a duplicated exon, rather than both and result in significant amounts of wild-type DMD mRNA. We tested this hypothesis in fibroblast cell lines derived from patients with a variety of single or multiple exon duplications that have been modified to allow transdifferentiation into a myogenic lineage. Using a variety of 2'O-methyl antisense oligonucleotides, significant skipping was induced for each duplication leading to a wild-type transcript as a major mRNA product. This study provides another proof of concept for the feasibility of therapeutic skipping in patients carrying exon duplications in order to express wild-type, full-length mRNA, although careful evaluation of the skipping efficiency should be performed as some exons are easier to skip than others. Such a personalized strategy is expected to be highly beneficial for this subset of DMD patients, compared to inducing expression of an internally-deleted dystrophin.

  12. First-line single agent treatment with gefitinib in patients with advanced non-small-cell lung cancer

    Directory of Open Access Journals (Sweden)

    Shu Yong-Qian

    2010-09-01

    Full Text Available Abstract Background Lung cancer is a malignant carcinoma which has the highest morbidity and mortality in Chinese population. Gefitinib, a tyrosine kinase (TK inhibitor of epidermal growth factor receptor (EGFR, displays anti-tumor activity. The present data regarding first-line treatment with single agent gefitinib against non-small-cell lung cancer (NSCLC in Chinese population are not sufficient. Purpose To assess the efficacy and toxicity of gefitinib in Chinese patients with advanced non-small-cell lung cancer (NSCLC, a study of single agent treatment with gefitinib in Chinese patients was conducted. Methods 45 patients with advanced NSCLC were treated with gefitinib (250 mg daily until the disease progression or intolerable toxicity. Results Among the 45 patients, 15 patients achieved partial response (PR, 17 patients experienced stable disease (SD, and 13 patients developed progression disease (PD. None of the patients achieved complete response (CR. The tumor response rate and disease control rate was 33% and 71.1%, respectively. Symptom remission rate was 72.5%, and median remission time was 8 days. Median overall survival and median progression-free survival was 15.3 months and 6.0 months, respectively. The main induced toxicities by gefitinib were skin rash and diarrhea (53.3% and 33.3%, respectively. The minor induced toxicities included dehydration and pruritus of skin (26.7% and 22.2%, respectively. In addition, hepatic toxicity and oral ulceration occurred in few patients (6.7% and 4.4%2, respectively. Conclusions Single agent treatment with gefitinib is effective and well tolerated in Chinese patients with advanced NSCLC.

  13. Protein-fold recognition using an improved single-source K diverse shortest paths algorithm.

    Science.gov (United States)

    Lhota, John; Xie, Lei

    2016-04-01

    Protein structure prediction, when construed as a fold recognition problem, is one of the most important applications of similarity search in bioinformatics. A new protein-fold recognition method is reported which combines a single-source K diverse shortest path (SSKDSP) algorithm with Enrichment of Network Topological Similarity (ENTS) algorithm to search a graphic feature space generated using sequence similarity and structural similarity metrics. A modified, more efficient SSKDSP algorithm is developed to improve the performance of graph searching. The new implementation of the SSKDSP algorithm empirically requires 82% less memory and 61% less time than the current implementation, allowing for the analysis of larger, denser graphs. Furthermore, the statistical significance of fold ranking generated from SSKDSP is assessed using ENTS. The reported ENTS-SSKDSP algorithm outperforms original ENTS that uses random walk with restart for the graph search as well as other state-of-the-art protein structure prediction algorithms HHSearch and Sparks-X, as evaluated by a benchmark of 600 query proteins. The reported methods may easily be extended to other similarity search problems in bioinformatics and chemoinformatics. The SSKDSP software is available at http://compsci.hunter.cuny.edu/~leixie/sskdsp.html. © 2016 Wiley Periodicals, Inc.

  14. Single walled carbon nanotube-based stochastic resonance device with molecular self-noise source

    Science.gov (United States)

    Fujii, Hayato; Setiadi, Agung; Kuwahara, Yuji; Akai-Kasaya, Megumi

    2017-09-01

    Stochastic resonance (SR) is an intrinsic noise usage system for small-signal sensing found in various living creatures. The noise-enhanced signal transmission and detection system, which is probabilistic but consumes low power, has not been used in modern electronics. We demonstrated SR in a summing network based on a single-walled carbon nanotube (SWNT) device that detects small subthreshold signals with very low current flow. The nonlinear current-voltage characteristics of this SWNT device, which incorporated Cr electrodes, were used as the threshold level of signal detection. The adsorption of redox-active polyoxometalate molecules on SWNTs generated additional noise, which was utilized as a self-noise source. To form a summing network SR device, a large number of SWNTs were aligned parallel to each other between the electrodes, which increased the signal detection ability. The functional capabilities of the present small-size summing network SR device, which rely on dense nanomaterials and exploit intrinsic spontaneous noise at room temperature, offer a glimpse of future bio-inspired electronic devices.

  15. STATSLAB: An open-source EEG toolbox for computing single-subject effects using robust statistics.

    Science.gov (United States)

    Campopiano, Allan; van Noordt, Stefon J R; Segalowitz, Sidney J

    2018-03-21

    Research on robust statistics during the past half century provides concrete evidence that classical hypothesis tests that rely on the sample mean and variance are problematic. Even seemingly minor departures from normality are now known to create major problems in terms of increased error rates and decreased power. Fortunately, numerous robust estimation techniques have been developed that circumvent the need for strict assumptions of normality and equal variances, leading to increased power and accuracy when testing hypotheses. Two robust methods that have been shown to have practical value across a wide range of applied situations are the trimmed mean and percentile bootstrap test. To facilitate the uptake of robust methods into the behavioural sciences, especially when dealing with trial-based data such as EEG, we introduce STATSLAB: An open-source EEG toolbox for computing single-subject effects using robust statistics. With the STATSLAB toolbox users can apply the percentile bootstrap test, with trimmed means, to a variety of neural signals including voltages, global field amplitude, and spectral features for both scalp channels and independent components. The toolbox offers a range of analytical strategies and is packaged with a fully functional graphical user interface that includes documentation. Copyright © 2018 Elsevier B.V. All rights reserved.

  16. Surface characterisation of MOCVD single source precursor grown GaSb-films

    Energy Technology Data Exchange (ETDEWEB)

    Seemayer, Andreas; Hommes, Alexander; Huemann, Sascha; Wandelt, Klaus [University of Bonn (Germany). Institute for Physical Chemistry; Hunger, Ralf [Hahn-Meitner-Institute Berlin GmbH, Berlin (Germany); Schulz, Stephan [University of Paderborn (Germany). Department Chemie

    2008-07-01

    III-V semiconductor films used for opto- and microelectronic devices have traditionally been grown by (MO)MBE and LPE processes. An alternative metal-organic CVD-process, which has been established in the last two decades for high-throughput and low-cost fabrication works for nitrides, phosphides and arsenides, but is problematic for antimonides. In particular, for GaSb films an alternative route is a CVD-process using the heterocyclic single source precursor [tBu{sub 2}GaSbEt{sub 2}]{sub 2}. Subject of the present work is the investigation of the surface physical properties of the produced films as well as the gas phase behaviour of the used precursor. Therefore films were produced on a Si(100) substrate in a HV-MOCVD reactor and investigated using AES, S-XPS and AFM. In addition, growth experiments under UHV conditions were performed. The results are discussed in terms of a correlation of the electronic properties with the composition and structure of the films.

  17. Resource allocation for two source-destination pairs sharing a single relay with a buffer

    KAUST Repository

    Zafar, Ammar

    2014-05-01

    In this paper, we obtain the optimal resource allocation scheme in order to maximize the achievable rate region in a dual-hop system that consists of two independent source-destination pairs sharing a single half-duplex relay. The relay decodes the received information and possesses buffers to enable storing the information temporarily before forwarding it to the respective destination. We consider both non-orthogonal transmission with successive interference cancellation at the receivers and orthogonal transmission. Also, we consider Gaussian block-fading channels and we assume that the channel state information is known and that no delay constraints are required. We show that, with the aid of buffering at the relay, joint user-and-hop scheduling is optimal and can enhance the achievable rate significantly. This is due to the joint exploitation of multiuser diversity and multihop diversity in the system. We provide closed-form expressions to characterize the average achievable rates in a generic form as functions of the statistical model of the channels. Furthermore, we consider sub-optimal schemes that exploit the diversity in the system partially and we provide numerical results to compare the different schemes and demonstrate the gains of the optimal one. © 2014 IEEE.

  18. Modeling of Single Event Transients With Dual Double-Exponential Current Sources: Implications for Logic Cell Characterization

    Science.gov (United States)

    Black, Dolores A.; Robinson, William H.; Wilcox, Ian Z.; Limbrick, Daniel B.; Black, Jeffrey D.

    2015-08-01

    Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. An accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventional model based on one double-exponential source can be incomplete. A small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. The parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.

  19. Tension-saturated and unsaturated flows from line sources in subsurface irrigation: Riesenkampf's and Philip's solutions revisited

    Science.gov (United States)

    Kacimov, A. R.; Obnosov, Yu. V.

    2016-03-01

    Riesenkampf's (1938), R-38 (referred to here as R-38), analytical solution for steady 2-D flow from a buried line source in a homogeneous Green-Ampt soil, with a wetting plume bounded by a free surface (capillary fringe), is compared with Philip's (1969), (P-69), one for genuinely unsaturated wetting of Gardner's infinite-extension soil. Conformal mappings are used in R-38, from which we derived the flow net, pore-water isobars, isochrones, fields of Darcian velocity and resultant force acting on saturated porous skeleton, fine geometry (shape and size) of the constant-head contour encompassing a mole-emitter or leaky-pipe, as well as the dependence of the total discharge per unit pipe length on uniform pressure in the pipe, capillarity of the soil, radius of the pipe, and saturated hydraulic conductivity. An ovalic "water table" isobar, encompassing P-69 source, is compared with one of R-38 for a fixed discharge and saturated conductivity but adjusted sorptive numbers. The Whisler and Bouwer (1970) relation between the static height of capillary rise and sorptive number is shown to give a good match between R-38 and P-69 isobars. This allows to use R-38 in the source vicinity and P-69 in the far-field zone. Computer algebra (Mathematica) routines are used for visualization of the known and extended R-38 and P-69 solutions.

  20. UPregulated single-stranded DNA-binding protein 1 induces cell chemoresistance to cisplatin in lung cancer cell lines.

    Science.gov (United States)

    Zhao, Xiang; He, Rong; Liu, Yu; Wu, Yongkai; Kang, Leitao

    2017-07-01

    Cisplatin and its analogues are widely used as anti-tumor drugs in lung cancer but many cisplatin-resistant lung cancer cases have been identified in recent years. Single-stranded DNA-binding protein 1 (SSDBP1) can effectively induce H69 cell resistance to cisplatin in our previous identification; thus, it is necessary to explore the mechanism underlying the effects of SSDBP1-induced resistance to cisplatin. First, SSDBP1-overexpressed or silent cell line was constructed and used to analyze the effects of SSDBP1 on chemoresistance of lung cancer cells to cisplatin. SSDBP1 expression was assayed by real-time PCR and Western blot. Next, the effects of SSDBP1 on cisplatin sensitivity, proliferation, and apoptosis of lung cancer cell lines were assayed by MTT and flow cytometry, respectively; ABC transporters, apoptosis-related genes, and cell cycle-related genes by real-time PCR, and DNA wound repair by comet assay. Low expression of SSDBP1 was observed in H69 cells, while increased expression in cisplatin-resistant H69 cells. Upregulated expression of SSDBP1 in H69AR cells was identified to promote proliferation and cisplatin resistance and inhibit apoptosis, while downregulation of SSDBP1 to inhibit cisplatin resistance and proliferation and promoted apoptosis. Moreover, SSDBP1 promoted the expression of P2gp, MRP1, Cyclin D1, and CDK4 and inhibited the expression of caspase 3 and caspase 9. Furthermore, SSDBP1 promoted the DNA wound repair. These results indicated that SSDBP1 may induce cell chemoresistance of cisplatin through promoting DNA repair, resistance-related gene expression, cell proliferation, and inhibiting apoptosis.

  1. Single window for issuing licenses for export and import of ionizing radiation sources and transit of radioactive sources

    International Nuclear Information System (INIS)

    Sandev, T.; Stamenov, R.; Misevska, A.; Georgievska-Dimitrevski, B.; Angelovski, G.

    2009-01-01

    In this paper we present the electronic system for application and issuing licenses for export, import and transit of goods (EXIM), particularly for ionizing radiation sources, in the Republic of Macedonia. This system is a modern and helpful tool for simple issuing licenses, for establishing a unique database and it represents a harmonized system for exchanging information between the governmental, public and private legal persons in the Republic of Macedonia. (author)

  2. Single photon sources using oxide apertured micropillars with integrated electrical control for novel functionalities

    Science.gov (United States)

    Stoltz, Nicholas G.

    The goal of this thesis is to apply the oxide apertured vertical cavity laser structure in order to explore quantum dot-microcavity coupling for the development of novel single photon sources (SPS). Optical microcavities combined with active emitters provide an opportunity to study the light matter interaction on a fundamental level. Edward Purcell first theorized in 1947 that the spontaneous emission (SE) rate of an optical emitter could be modified in the presence of an optical cavity. As semiconductor microcavity technology has advanced many optoelectronic devices have benefited from the increased SE rates predicted by the Purcell effect. The development of quantum emitters on an integrated semiconductor platform in the form of semiconductor self-assembled quantum dots (QDs) has expanded applications in the field. Coupling atomic emitters to optical microcavities in the solid state allows for the study of cavity quantum electrodynamics and the fabrication single photon (SP) devices. Optoelectronic devices providing non-classical light states have a broad range of applications in quantum information science, including quantum key distribution systems, quantum lithography, and quantum computing. Here, the oxide apertured micropillar approach demonstrates high quality microcavities with cavity quality factors up to 50,000 and measured Purcell enhancements of 10. In addition the inherent advantages provided by the oxide apertured micropillar, specifically high collection efficiency, have produced SPSs with record high SP rates and quantum efficiencies representing a six-fold improvement over reported values. In addition we have developed and integrated a scheme allowing for on-chip electrical control of SP devices for the implementation of SPSs with novel functionalities. The active electrical control of QD charge state has allowed for the elimination of dark states which severely limit SP rates and efficiencies. The active electrical tuning of QD emission energy

  3. Evolutionary dynamics of Vibrio cholerae O1 following a single-source introduction to Haiti.

    Science.gov (United States)

    Katz, Lee S; Petkau, Aaron; Beaulaurier, John; Tyler, Shaun; Antonova, Elena S; Turnsek, Maryann A; Guo, Yan; Wang, Susana; Paxinos, Ellen E; Orata, Fabini; Gladney, Lori M; Stroika, Steven; Folster, Jason P; Rowe, Lori; Freeman, Molly M; Knox, Natalie; Frace, Mike; Boncy, Jacques; Graham, Morag; Hammer, Brian K; Boucher, Yan; Bashir, Ali; Hanage, William P; Van Domselaar, Gary; Tarr, Cheryl L

    2013-07-02

    study an isolated, single-source outbreak of Vibrio cholerae O1 over an established time frame. By using multiple approaches to assay genetic variation, we found no evidence that the Haiti strain has acquired any genes by horizontal gene transfer, an observation that led us to discover that it is also poorly transformable. We have found no evidence that environmental strains have played a role in the evolution of the outbreak strain.

  4. Doppler shift measurement of Balmer-alpha line spectrum emission from a plasma in a negative hydrogen ion source

    International Nuclear Information System (INIS)

    Wada, M.; Doi, K.; Kisaki, M.; Nakano, H.; Tsumori, K.; Nishiura, M.

    2015-01-01

    Balmer-α light emission from the extraction region of the LHD one-third ion source has shown a characteristic Doppler broadening in the wavelength spectrum detected by a high resolution spectrometer. The spectrum resembles Gaussian distribution near the wavelength of the intensity peak, while it has an additional component of a broader foot. The measured broadening near the wavelength of the intensity peak corresponds to 0.6 eV hydrogen atom temperature. The spectrum exhibits a larger expansion in the blue wing which becomes smaller when the line of sight is tilted toward the driver region from the original observation axis parallel to the plasma grid. A surface collision simulation model predicts the possibility of hydrogen reflection at the plasma grid surface to form a broad Balmer-α light emission spectrum

  5. Continuous-wave, singly resonant parametric oscillator-based mid-infrared optical vortex source.

    Science.gov (United States)

    Aadhi, A; Sharma, Varun; Singh, R P; Samanta, G K

    2017-09-15

    We report on a high-power, continuous-wave source of optical vortices tunable in the mid-infrared (mid-IR) wavelength range. Using the orbital angular momentum (OAM) conservation of the parametric processes and the threshold conditions of the cavity modes of the singly resonant optical parametric oscillator (SRO), we have transferred the OAM of the pump beam at the near-infrared wavelength to the idler beam tunable in the mid-IR. Pumped with a vortex beam of order l p =1 at 1064 nm, the SRO, configured in a four curved mirror-based ring cavity with a 50 mm long MgO-doped periodically poled LiNbO 3 crystal, produces an idler beam with an output power in excess of 2 W in a vortex spatial profile with the order l i =1, tunable across 2217-3574 nm and corresponding signal beam in Gaussian intensity distribution across 1515-2046 nm. For pump vortices of the order l p =1 and 2, and a power of 22 W, the SRO produces idler vortices of the same order as that of the pump beam with a maximum power of 5.23 and 2.3 W, corresponding to near-IR to mid-IR vortex conversion efficiency of 23.8% and 10.4%, respectively. The idler vortex beam has a spectral width, and a passive rms power stability of 101 MHz and 4.9% over 2 h, respectively.

  6. Reliable underwater dipole source characterization in 3D space by an optimally designed artificial lateral line system.

    Science.gov (United States)

    Ahrari, Ali; Lei, Hong; Sharif, Montassar Aidi; Deb, Kalyanmoy; Tan, Xiaobo

    2017-04-19

    Inspired by the lateral line of aquatic vertebrates, an artificial lateral line (ALL) system can localize and track an underwater moving object by analyzing the ambient flow caused by its motion. There are several studies on object detection, localization and tracking by ALL systems, but only a few have investigated the optimal design of the ALL system, the one that on average provides the highest characterization accuracy. Design optimization is particularly important because the uncertainties in the employed flow model and in sensor measurements deteriorate the reliability of sensing. This study investigates the optimal design of the ALL system in three-dimensional (3D) space for dipole source characterization. It highlights some challenges specific to the 3D setting and demonstrates the shortcomings of the designs in which all sensors and their sensing directions are in the same plane. As an alternative, it proposes two design concepts, called 'Offset Strategy' and 'Angle Strategy' to overcome these shortcomings. It investigates potentials of having a swarm of cooperative ALLs as well. It performs design optimization in the presence of sensor and model uncertainties and analyzes the trade-off between the number of sensors and characterization accuracy. The obtained solutions are analyzed to reveal their strategies in solving the problem efficiently. The dependency of the optimized solutions on the uncertainties is also demonstrated.

  7. The different biological effects of single, fractioned and continuous low dose rate radiation on CL187 colorectal cancer cell line

    International Nuclear Information System (INIS)

    Wang Hao; Wang Junjie; Qu Ang; Li Jin'na; Liu Jingjia

    2012-01-01

    Objective: To investigate the effect and underlying mechanism of single, fractioned and continuous low dose rate radiation on CL187 colorectal cancer cell line. Methods: CL187 cells were exposed to 6 MV X-rays at a high dose rate of 4 Gy/min and 125 I seed at a low dose rate of 2.77 cGy/h with three groups:single dose radiation group (SDR), fractioned dose radiation group (FDR) by 2 Gy/f, and continuous low dose rate radiation group (CLDR). The radiation doses were 0, 2, 4 and 8 Gy. Total cell number and cell viability were determined by trypan blue. Clone forming assay was used to evaluate the cell proliferation ability. The percentage of apoptosis cells was analyzed by flow cytometry. Western blot was used to detect the protein expression levels of PHLPP2, PTEN and Bax. Results: Compared with SDR and FDR groups, the total cell number and survival fraction of CLDR group decreased. The relative biological effect (RBE) for 125 I seeds compared with 6 MV X-rays was 1.41. The percentage of apoptosis cells of CLDR group was significantly increased (t=-15.08, -11.99, P<0.05). The expression level of Bax increased in CLDR group, while no obvious changes were observed on PHLPP2 and PTEN among three groups. Conclusions: The expression level of PHLPP2 increases in SDR, FDR and CLDR group, while it seems that it was not influenced by dose rate. The expression level of Bax increased in three groups, while more colorectal CL187 cells in CLDR group may be killed due to the increase of Bax expression. (authors)

  8. On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kristie Cooper; Gary Pickrell; Anbo Wang

    2005-11-01

    This report summarizes technical progress April-September 2005 on the Phase II program ''On-Line Self-Calibrating Single Crystal Sapphire Optical Sensor Instrumentation for Accurate and Reliable Coal Gasifier Temperature Measurement'', funded by the Federal Energy Technology Center of the U.S. Department of Energy, and performed by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering at Virginia Tech. The outcome of the first phase of this program was the selection of broadband polarimetric differential interferometry (BPDI) for further prototype instrumentation development. This approach is based on the measurement of the optical path difference (OPD) between two orthogonally polarized light beams in a single-crystal sapphire disk. The objective of this program is to bring the sensor technology, which has already been demonstrated in the laboratory, to a level where the sensor can be deployed in the harsh industrial environments and will become commercially viable. Due to the difficulties described on the last report, field testing of the BPDI system has not continued to date. However, we have developed an alternative high temperature sensing solution, which is described in this report. The sensing system will be installed and tested at TECO's Polk Power Station. Following a site visit in June 2005, our efforts have been focused on preparing for that field test, including he design of the sensor mechanical packaging, sensor electronics, the data transfer module, and the necessary software codes to accommodate this application.. We are currently ready to start sensor fabrication.

  9. A Control Source Structure of Single Loudspeaker and Rear Sound Interference for Inexpensive Active Noise Control

    Directory of Open Access Journals (Sweden)

    Yasuhide Kobayashi

    2010-01-01

    phase-lag is imposed by the Swinbanks' source and the rear sound interference. Thirdly, effects on control performances of control source structures are examined by control experiments with robust controllers.

  10. Comparison of image quality and radiation dose between split-filter dual-energy images and single-energy images in single-source abdominal CT.

    Science.gov (United States)

    Euler, André; Obmann, Markus M; Szucs-Farkas, Zsolt; Mileto, Achille; Zaehringer, Caroline; Falkowski, Anna L; Winkel, David J; Marin, Daniele; Stieltjes, Bram; Krauss, Bernhard; Schindera, Sebastian T

    2018-02-19

    To compare image quality and radiation dose of abdominal split-filter dual-energy CT (SF-DECT) combined with monoenergetic imaging to single-energy CT (SECT) with automatic tube voltage selection (ATVS). Two-hundred single-source abdominal CT scans were performed as SECT with ATVS (n = 100) and SF-DECT (n = 100). SF-DECT scans were reconstructed and subdivided into composed images (SF-CI) and monoenergetic images at 55 keV (SF-MI). Objective and subjective image quality were compared among single-energy images (SEI), SF-CI and SF-MI. CNR and FOM were separately calculated for the liver (e.g. CNR liv ) and the portal vein (CNR pv ). Radiation dose was compared using size-specific dose estimate (SSDE). Results of the three groups were compared using non-parametric tests. Image noise of SF-CI was 18% lower compared to SEI and 48% lower compared to SF-MI (p 0.628). Subjective sharpness was equal between single-energy and monoenergetic images and diagnostic confidence was equal between single-energy and composed images. FOM liv was highest for SF-CI. FOM pv was equal for SEI and SF-MI (p = 0.78). SSDE was significant lower for SF-DECT compared to SECT (p quality at lower radiation dose compared to single-energy CT with ATVS. • Split-filter dual-energy results in 18% lower noise compared to single-energy with ATVS. • Split-filter dual-energy results in 11% lower SSDE compared to single-energy with ATVS. • Spectral shaping of split-filter dual-energy leads to an increased dose-efficiency.

  11. Detecting the single line to ground short circuit fault in the submarine’s power system using the artificial neural network

    Directory of Open Access Journals (Sweden)

    Behniafar Ali

    2013-01-01

    Full Text Available The electric marine instruments are newly inserted in the trade and industry, for which the existence of an equipped and reliable power system is necessitated. One of the features of such a power system is that it cannot have an earth system causing the protection relays not to be able to detect the single line to ground short circuit fault. While on the other hand, the occurrence of another similar fault at the same time can lead to the double line fault and thereby the tripping of relays and shortening of vital loads. This in turn endangers the personals' security and causes the loss of military plans. From the above considerations, it is inferred that detecting the single line to ground fault in the marine instruments is of a special importance. In this way, this paper intends to detect the single line to ground fault in the power systems of the marine instruments using the wavelet transform and Multi-Layer Perceptron (MLP neural network. In the numerical analysis, several different types of short circuit faults are simulated on several marine power systems and the proposed approach is applied to detect the single line to ground fault. The results are of a high quality and preciseness and perfectly demonstrate the effectiveness of the proposed approach.

  12. Probing the importance of clonality: Single cell subcloning of clonally derived CHO cell lines yields widely diverse clones differing in growth, productivity, and product quality.

    Science.gov (United States)

    Ko, Peggy; Misaghi, Shahram; Hu, Zhilan; Zhan, Dejin; Tsukuda, Joni; Yim, Mandy; Sanford, Mark; Shaw, David; Shiratori, Masaru; Snedecor, Brad; Laird, Michael; Shen, Amy

    2017-12-11

    In the past few decades, a large variety of therapeutic antibodies and proteins have been expressed in Chinese hamster ovary (CHO) cells. This mammalian expression system is robust, scalable, relatively inexpensive, and importantly allows for post-translational modifications that are important for some therapeutic proteins. Historically, CHO cell lines were derived from colonies of cells grown in semi-solid or liquid plates using either serum-containing or serum-free media. Current advancements in cell sorting and imaging technologies have allowed for isolating and imaging single cell progenitors at the seeding step, significantly increasing the probability of isolating clonally derived cell lines. However, it is debatable how much population heterogeneity can be eliminated when clonally derived cell lines, originated from a single cell progenitor, are scaled up. To further investigate this phenomenon, we subcloned two different clonally derived (day 0 imaged and visually inspected) cell lines expressing antibody-X. The results showed that when six randomly chosen subclones of each line were evaluated in a production assay, these subclones displayed a range of variation in titer, specific productivity, growth, and product quality attributes. Some subclones displayed variations in transgene copy numbers. Additionally, clonal derivation did not assure stability of the derived cell lines. Our findings show that cell heterogeneity exists in a population even when derived from a single cell progenitor. © 2017 American Institute of Chemical Engineers Biotechnol. Prog., 2017. © 2017 American Institute of Chemical Engineers.

  13. Development of Theoretical and Computational Methods for Single-Source Bathymetric Data

    Science.gov (United States)

    2016-09-15

    sources ofinformation must be taken into account in order to establish the safe op- erating envelope for the vessel. Sources include electronic charts at...uncer- tainty in the reconstruction engendered by the data. Applied spatially, this method provides, for each source, a ternary spatial classi- fication

  14. A Novel Protection Method for Single Line-to-Ground Faults in Ungrounded Low-Inertia Microgrids

    Directory of Open Access Journals (Sweden)

    Liuming Jing

    2016-06-01

    Full Text Available This paper proposes a novel protection method for single line-to-ground (SLG faults in ungrounded low-inertia microgrids. The proposed method includes microgrid interface protection and unit protection. The microgrid interface protection is based on the difference between the zero-sequence voltage angle and the zero-sequence current angle at the microgrid interconnection transformer for fast selection of the faulty feeder. The microgrid unit protection is based on a comparison of the three zero-sequence current phase directions at each junction point of load or distributed energy resources. Methods are also included to locate the minimum fault section. The fault section location technology operates according to the coordination of microgrid unit protection. The proposed method responds to SLG faults that may occur in both the grid and the microgrid. Simulations of an ungrounded low-inertia microgrid with a relay model were carried out using Power System Computer Aided Design (PSCAD/Electromagnetic Transients including DC (EMTDC.

  15. 76 FR 53913 - Award of an Urgent Single-Source Grant to Survivors of Torture International (SOTI) in San Diego...

    Science.gov (United States)

    2011-08-30

    ... Torture International (SOTI) in San Diego, CA; Correction AGENCY: Office of Refugee Resettlement, ACF, HHS... urgent single-source grant to Survivors of Torture, International (SOTI), San Diego, CA. The document... the Torture Victims Relief Act (TVRA) of 1998,'' Public Law 105-320 (22 U.S.C. 2152 note...

  16. 76 FR 67192 - Administration on Children, Youth and Families Announces the Award of Five Single-Source...

    Science.gov (United States)

    2011-10-31

    ... training and supports for Tribal middle managers in child welfare. There are five traineeship universities... DEPARTMENT OF HEALTH AND HUMAN SERVICES Administration for Children and Families Administration on Children, Youth and Families Announces the Award of Five Single-Source Expansion Supplement Grants To...

  17. 76 FR 67195 - Announcing the Award of a Single-Source Program Expansion Supplement Grant to the Johns Hopkins...

    Science.gov (United States)

    2011-10-31

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Administration for Children and Families Announcing the Award of a Single-Source Program Expansion Supplement Grant to the Johns Hopkins University, Bloomberg School of Public Health in Baltimore, MD, To Support the Development of a Human Services National...

  18. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  19. 76 FR 54235 - Supplement to the FY2010 Single-Source Cooperative Agreement With the World Health Organization...

    Science.gov (United States)

    2011-08-31

    ... Cooperative Agreement With the World Health Organization (WHO) AGENCY: Biomedical Advanced Research... supplement the FY2010 ``Single-Source Cooperative Agreement with the World Health Organization (WHO) to...-economy countries worldwide via a cooperative agreement with the World Health Organization (WHO). The...

  20. 75 FR 66380 - Award of a Single-Source Grant to the Commonwealth Election Commission of Saipan, Commonwealth of...

    Science.gov (United States)

    2010-10-28

    ... officials, poll workers, and election volunteers on the best methods to promote the access and participation... Commonwealth Election Commission of Saipan, Commonwealth of the Northern Mariana Islands (CNMI) AGENCY...), Administration on Developmental Disabilities (ADD) has awarded a single-source grant to the Commonwealth Election...

  1. Analysis of carbon monoxide (CO) with Delhi Finite Line Source (DFLS) in MT Haryono Street, Medan City

    Science.gov (United States)

    Turmuzi, M.; Suryati, I.; Mashaly, E. T.; Batubara, F.

    2018-02-01

    One source to decrease urban air ambient quality is transportation sector. Important pollutants are released by gas emissions from vehicles are carbon monoxide (CO), hydrocarbons (HC), nitrogen dioxide (NO2), particulate matter and others. The presence of CO pollutants in the ambient air can be predicted by modeling air quality. This study aims to estimate CO concentration resulting from transportation activities using Delhi Finite Line Source (DFLS) model, comparing CO prediction using a DFLS model with CO observation in the field, and determine the suitability of the DFLS model application on the MT Haryono street in Medan City. Research was conducted for 3 days at two sample points with frequency twice daily. Based on research results, the range of CO concentration from observation between 22.903 μg/m3 - 27.484 μg/m3. CO observation is still below the ambient air quality standard. According to the DFLS calculations, the range of CO concentration between 1.499 μg/m3- 2.051 μg/m3. The calculation index of agreement (IOA) validation test obtained value of d = 0.22. The DFLS model is not suitable to be applied on MT Haryono street because many factors affected such as wind direction and wind velocity, ambient air temperature and humidity

  2. Transmitted sound field due to an impulsive line acoustic source bounded by a plate followed by a vortex sheet

    Science.gov (United States)

    Miura, T.; Chao, C. C.

    1980-01-01

    The propagation of sound due to a line acoustic source in the moving stream across a semiinfinite vortex sheet which trails from a rigid plate is examined in a linear theory for the subsonic case. A solution for the transmitted sound field is obtained with the aid of multiple integral transforms and the Wiener-Hopf technique for both the steady state (time harmonic) and initial value (impulsive source) situations. The contour of inverse transform and hence the decomposition of the functions are determined through causality and radiation conditions. The solution obtained satisfies causality and the full Kutta conditions. The transmitted sound field is composed of two waves in both the stady state and initial value problems. One is the wave scattered from the edge of the plate which is associated with the bow wave and the instability wave. These waves exist in the downstream sectors. The other is the wave transmitted through the vortex sheet which is also associated with the instability wave. Regional divisions of the transmitted sound field are identified.

  3. Near single-line operation of a free-burning CS2/O2/N2O flame laser with a nondispersive optical cavity

    International Nuclear Information System (INIS)

    Foster, K.D.; Kimbell, G.H.; Snelling, D.R.

    1975-01-01

    The CS 2 /O 2 /N 2 O flame laser has been operated for the first time under conditions in which the spectral output is nearly single line. This transition is the P 10 - 9 (17) of CO at 5.4265 μm, the same transition which was observed to oscillate in single-line fashion by Hirose et al. in an electrically initiated CO chemical laser. It is suggested that the unique behavior of this line may be due to its close proximity to a P branch transition in an adjacent band, namely the P 9 - 8 (23) line, such that the gain profiles of the two lines overlap. Calculations suggest that at the conditions of these experiments, the separation of the line centers for this pair is about 0.3 A or less. The P 10 - 9 (17) transition was also found to be totally absent under certain conditions of high multiline power, particulary at low O 2 and N 2 O flows. This may be due to absorption by a high-band R branch transition at 5.4266 μm, namely the R 15 - 16 (32) line. (U.S.)

  4. Hybrid subtractive-additive-welding microfabrication for lab-on-chip applications via single amplified femtosecond laser source

    Science.gov (United States)

    Jonušauskas, Linas; Rekštytė, Sima; Buividas, Ričardas; Butkus, Simas; Gadonas, Roaldas; Juodkazis, Saulius; Malinauskas, Mangirdas

    2017-09-01

    An approach employing ultrafast laser hybrid subtractive-additive microfabrication, which combines ablation, three-dimensional nanolithography, and welding, is proposed for the realization of a lab-on-chip (LOC) device. A single amplified Yb:KGW femtosecond (fs)-pulsed laser source is shown to be suitable for fabricating microgrooves in glass slabs, polymerization of fine-meshes microfilter out of hybrid organic-inorganic photopolymer SZ2080 inside them, and, finally, sealing the whole chip with cover glass into a single monolithic piece. The created microfluidic device proved its particle sorting function by separating 1- and 10-μm polystyrene spheres in an aqueous mixture. All together, this proves that laser microfabrication based on a single amplified fs laser source is a flexible and versatile approach for the hybrid subtractive-additive manufacturing of functional mesoscale multimaterial LOC devices.

  5. Line-source simulation for shallow-seismic data. Part 2: full-waveform inversion—a synthetic 2-D case study

    Science.gov (United States)

    Schäfer, M.; Groos, L.; Forbriger, T.; Bohlen, T.

    2014-09-01

    Full-waveform inversion (FWI) of shallow-seismic surface waves is able to reconstruct lateral variations of subsurface elastic properties. Line-source simulation for point-source data is required when applying algorithms of 2-D adjoint FWI to recorded shallow-seismic field data. The equivalent line-source response for point-source data can be obtained by convolving the waveforms with √{t^{-1}} (t: traveltime), which produces a phase shift of π/4. Subsequently an amplitude correction must be applied. In this work we recommend to scale the seismograms with √{2 r v_ph} at small receiver offsets r, where vph is the phase velocity, and gradually shift to applying a √{t^{-1}} time-domain taper and scaling the waveforms with r√{2} for larger receiver offsets r. We call this the hybrid transformation which is adapted for direct body and Rayleigh waves and demonstrate its outstanding performance on a 2-D heterogeneous structure. The fit of the phases as well as the amplitudes for all shot locations and components (vertical and radial) is excellent with respect to the reference line-source data. An approach for 1-D media based on Fourier-Bessel integral transformation generates strong artefacts for waves produced by 2-D structures. The theoretical background for both approaches is presented in a companion contribution. In the current contribution we study their performance when applied to waves propagating in a significantly 2-D-heterogeneous structure. We calculate synthetic seismograms for 2-D structure for line sources as well as point sources. Line-source simulations obtained from the point-source seismograms through different approaches are then compared to the corresponding line-source reference waveforms. Although being derived by approximation the hybrid transformation performs excellently except for explicitly back-scattered waves. In reconstruction tests we further invert point-source synthetic seismograms by a 2-D FWI to subsurface structure and evaluate

  6. jCompoundMapper: An open source Java library and command-line tool for chemical fingerprints.

    Science.gov (United States)

    Hinselmann, Georg; Rosenbaum, Lars; Jahn, Andreas; Fechner, Nikolas; Zell, Andreas

    2011-01-10

    The decomposition of a chemical graph is a convenient approach to encode information of the corresponding organic compound. While several commercial toolkits exist to encode molecules as so-called fingerprints, only a few open source implementations are available. The aim of this work is to introduce a library for exactly defined molecular decompositions, with a strong focus on the application of these features in machine learning and data mining. It provides several options such as search depth, distance cut-offs, atom- and pharmacophore typing. Furthermore, it provides the functionality to combine, to compare, or to export the fingerprints into several formats. We provide a Java 1.6 library for the decomposition of chemical graphs based on the open source Chemistry Development Kit toolkit. We reimplemented popular fingerprinting algorithms such as depth-first search fingerprints, extended connectivity fingerprints, autocorrelation fingerprints (e.g. CATS2D), radial fingerprints (e.g. Molprint2D), geometrical Molprint, atom pairs, and pharmacophore fingerprints. We also implemented custom fingerprints such as the all-shortest path fingerprint that only includes the subset of shortest paths from the full set of paths of the depth-first search fingerprint. As an application of jCompoundMapper, we provide a command-line executable binary. We measured the conversion speed and number of features for each encoding and described the composition of the features in detail. The quality of the encodings was tested using the default parametrizations in combination with a support vector machine on the Sutherland QSAR data sets. Additionally, we benchmarked the fingerprint encodings on the large-scale Ames toxicity benchmark using a large-scale linear support vector machine. The results were promising and could often compete with literature results. On the large Ames benchmark, for example, we obtained an AUC ROC performance of 0.87 with a reimplementation of the extended

  7. Internal validation of STRmix™ for the interpretation of single source and mixed DNA profiles.

    Science.gov (United States)

    Moretti, Tamyra R; Just, Rebecca S; Kehl, Susannah C; Willis, Leah E; Buckleton, John S; Bright, Jo-Anne; Taylor, Duncan A; Onorato, Anthony J

    2017-07-01

    The interpretation of DNA evidence can entail analysis of challenging STR typing results. Genotypes inferred from low quality or quantity specimens, or mixed DNA samples originating from multiple contributors, can result in weak or inconclusive match probabilities when a binary interpretation method and necessary thresholds (such as a stochastic threshold) are employed. Probabilistic genotyping approaches, such as fully continuous methods that incorporate empirically determined biological parameter models, enable usage of more of the profile information and reduce subjectivity in interpretation. As a result, software-based probabilistic analyses tend to produce more consistent and more informative results regarding potential contributors to DNA evidence. Studies to assess and internally validate the probabilistic genotyping software STRmix™ for casework usage at the Federal Bureau of Investigation Laboratory were conducted using lab-specific parameters and more than 300 single-source and mixed contributor profiles. Simulated forensic specimens, including constructed mixtures that included DNA from two to five donors across a broad range of template amounts and contributor proportions, were used to examine the sensitivity and specificity of the system via more than 60,000 tests comparing hundreds of known contributors and non-contributors to the specimens. Conditioned analyses, concurrent interpretation of amplification replicates, and application of an incorrect contributor number were also performed to further investigate software performance and probe the limitations of the system. In addition, the results from manual and probabilistic interpretation of both prepared and evidentiary mixtures were compared. The findings support that STRmix™ is sufficiently robust for implementation in forensic laboratories, offering numerous advantages over historical methods of DNA profile analysis and greater statistical power for the estimation of evidentiary weight, and

  8. Single Amplified Genomes as Source for Novel Extremozymes: Annotation, Expression and Functional Assessment

    KAUST Repository

    Grötzinger, Stefan

    2017-12-01

    Enzymes, as nature’s catalysts, show remarkable abilities that can revolutionize the chemical, biotechnological, bioremediation, agricultural and pharmaceutical industries. However, the narrow range of stability of the majority of described biocatalysts limits their use for many applications. To overcome these restrictions, extremozymes derived from microorganisms thriving under harsh conditions can be used. Extremophiles living in high salinity are especially interesting as they operate at low water activity, which is similar to conditions used in standard chemical applications. Because only about 0.1 % of all microorganisms can be cultured, the traditional way of culture-based enzyme function determination needs to be overcome. The rise of high-throughput next-generation-sequencing technologies allows for deep insight into nature’s variety. Single amplified genomes (SAGs) specifically allow for whole genome assemblies from small sample volumes with low cell yields, as are typical for extreme environments. Although these technologies have been available for years, the expected boost in biotechnology has held off. One of the main reasons is the lack of reliable functional annotation of the genomic data, which is caused by the low amount (0.15 %) of experimentally described genes. Here, we present a novel annotation algorithm, designed to annotate the enzymatic function of genomes from microorganisms with low homologies to described microorganisms. The algorithm was established on SAGs from the extreme environment of selected hypersaline Red Sea brine pools with 4.3 M salinity and temperatures up to 68°C. Additionally, a novel consensus pattern for the identification of γ-carbonic anhydrases was created and applied in the algorithm. To verify the annotation, selected genes were expressed in the hypersaline expression system Halobacterium salinarum. This expression system was established and optimized in a continuously stirred tank reactor, leading to

  9. The Application Three-phase to Single-phase Z-Source Matrix Converter in Wind Turbine

    Directory of Open Access Journals (Sweden)

    vahid asadi rad

    2017-01-01

    Full Text Available In this paper a new idea of direct three-phase to single-phase Z-source matrix converter (impedance-source matrix converter applicable in stand-alone wind turbine is introduced. In the direct Z-source matrix converter amplitude of output voltage and frequency regulation are of importance to control system. In wind turbines, input voltage and frequency are usually changing due to wind speed variation that these alterations could be easily regulated by means of a direct Z-source matrix converter. A scheme is also offered to control the proposed direct three-phase to single-phase Z-source matrix converter. the control strategy would be able to adjust the output voltage and frequency at desired value as well as producing low THD (total harmonic distortion at the output voltage. The proposed structure and the control methodology are simulated using matlab simulink software and results are investigated and discussed to confirm the performance of the direct Z-source matrix converter in wind turbine.

  10. Vacuum chamber with distributed titanium sublimation pumping for the G-line wiggler at Cornell High Energy Synchrotron Source

    International Nuclear Information System (INIS)

    Li, Y.; He, Y.; Mistry, N.B.

    2003-01-01

    This article describes a 3-m-long vacuum chamber for the new wiggler magnet at the Cornell Electron Storage Ring (CESR) for the synchrotron light beam line of the Cornell High Energy Synchrotron Source (CHESS). Copper was chosen as the main chamber material for its good electric and thermal conductivities. Proper mechanical design and welding procedure were implemented to meet very tight tolerances to ensure adequate vertical aperture for the stored beams in CESR while allowing the required small wiggler gap. Distributed titanium sublimation pumping is incorporated along the 3 m length of the chamber to provide sufficient pumping speed and capacity for CESR and CHESS operations. The chamber pumping performance was evaluated prior to installation. Linear distributed pumping speeds at the beam line of ∼720 l/s/m for N 2 and CO and ∼4000 l/s/m for H 2 were measured. The measured pumping capacities for N 2 , CO and H 2 are ∼1.0, ∼2.0 and ∼77 Torr l, respectively, for each titanium sublimation cycle. Measurements also showed that CO molecules adsorb on the N 2 and H 2 saturated titanium films with virtually the same initial sticking coefficient as on a fresh titanium film. Analyses indicated very different CO adsorption mechanisms between the N 2 and H 2 saturated titanium films. While the replacement of surface H 2 by CO was observed, little desorption of nitrogen was measured. Operational experience showed excellent vacuum pumping performance over two years after the chamber installation

  11. Small angle neutron scattering study of the magnetic flux-line lattice in single crystal 2H-NbSe2

    DEFF Research Database (Denmark)

    Gammel, P.L.; Huse, D.A.; Kleiman, R.N.

    1994-01-01

    We report on a small angle neutron scattering study of the flux-line lattice in single crystal 2H-NbSe2. As the magnetic field is tilted away from the crystalline c axis, we find distortions in the flux lattice as would be expected for a mass anisotropy GAMMA = 10.1 +/- 0.9. However, we find...

  12. Second-line pemetrexed treatment in Taiwanese patients with advanced nonsmall cell lung cancer: An open-label single-arm study

    Directory of Open Access Journals (Sweden)

    Gee-Chen Chang

    2013-09-01

    Conclusion: The objective response rate, disease control rate, and safety and tolerability profile in this population of Taiwanese patients were consistent with the published findings that were conducted using Asian and Western populations. These findings support the use of single-agent, second-line pemetrexed for the treatment of advanced nonsmall cell lung cancer in Taiwanese patients.

  13. Morphological changes in cultured bovine lymphoid cell lines associated with bovine viral diarrhea virus (BVDV) single and dual infections with bovine leukemia virus (BLV)

    Science.gov (United States)

    Currently, American Type Culture Collection (ATCC) makes available two cell lines derived from the same lymphoblast-like suspension cell that have been confirmed by next-generation sequencing and RT-PCR to have either a single contaminate of BVDV2a (CRL-8037) or dual contaminates of both BVDV and BL...

  14. Compact source of narrow-band counterpropagating polarization-entangled photon pairs using a single dual-periodically-poled crystal

    International Nuclear Information System (INIS)

    Gong, Yan-Xiao; Xie, Zhen-Da; Xu, Ping; Zhu, Shi-Ning; Yu, Xiao-Qiang; Xue, Peng

    2011-01-01

    We propose a scheme for the generation of counterpropagating polarization-entangled photon pairs from a dual-periodically-poled crystal. Compared with the usual forward-wave-type source, this source, in the backward-wave way, has a much narrower bandwidth. With a 2-cm-long bulk crystal, the bandwidths of the example sources are estimated to be 3.6 GHz, and the spectral brightnesses are more than 100 pairs/(s GHz mW). Two concurrent quasi-phase-matched spontaneous parametric down-conversion processes in a single crystal enable our source to be compact and stable. This scheme does not rely on any state projection and applies to both degenerate and nondegenerate cases, facilitating applications of the entangled photons.

  15. Methods for calibrating the gain and offset of the DSSC detector for the European XFEL using X-ray line sources

    Science.gov (United States)

    Schlee, S.; Weidenspointner, G.; Moch, D.; Kuster, M.; Porro, M.

    2016-01-01

    The DSSC (DEPFET Sensor with Signal Compression) will be a silicon based, 2d 1 Mpx imaging detector for the European X-ray Free Electron Laser Facility (XFEL.EU) in Hamburg, Germany. The DSSC is foreseen for soft X-radiation from 0.5 keV up to 6 keV . Driven by its scientific requirements, the design goals of the detector system are single photon detection, high dynamic range and a high frame rate of up to 4.5 MHz. Signal compression and amplification will be performed in the silicon sensor pixels yielding a low signal noise. Utilizing an in-pixel active filtering stage and an 8/9-bit ADC, the detector will provide parallel read-out of all pixels. In order to calibrate offset and gain, the procedure currently under investigation relies on determining peak positions in measurements with calibration line sources such as 55Fe. Here the status of studies of the stability and performance of a parameterized fit function designed for this task will be presented.

  16. Two-Step Single Particle Mass Spectrometry for On-Line Monitoring of Polycyclic Aromatic Hydrocarbons Bound to Ambient Fine Particulate Matter

    Science.gov (United States)

    Zimmermann, R.; Bente, M.; Sklorz, M.

    2007-12-01

    Polycyclic aromatic hydrocarbons (PAH) are formed as trace products in combustion processes and are emitted to the atmosphere. Larger PAH have low vapour pressure and are predominantly bound to the ambient fine particulate matter (PM). Upon inhalation, PAH show both, chronic human toxicity (i.e. many PAH are potent carcinogens) as well as acute human toxicity (i.e. inflammatory effects due to oxi-dative stress) and are discussed to be relevant for the observed health effect of ambient PM. Therefore a better understanding of the occurrence, dynamics and particle size dependence of particle bound-PAH is of great interest. On-line aerosol mass spectrometry in principle is the method of choice to investigate the size resolved changes in the chemical speciation of particles as well the status of internal vs. external mixing of chemical constituents. However the present available aerosol mass spectrometers (ATOFMS and AMS) do not allow detection of PAH from ambient air PM. In order to allow a single particle based monitoring of PAH from ambient PM a new single particle laser ionisation mass spectrometer was built and applied. The system is based on ATOFMS principle but uses a two- step photo-ionization. A tracked and sized particle firstly is laser desorbed (LD) by a IR-laser pulse (CO2-laser, λ=10.2 μm) and subsequently the released PAH are selectively ionized by an intense UV-laser pulse (ArF excimer, λ=248 nm) in a resonance enhanced multiphoton ionisation process (REMPI). The PAH-ions are detected in a time of flight mass spectrometer (TOFMS). A virtual impactor enrichment unit is used to increase the detection frequency of the ambient particles. With the current inlet system particles from about 400 nm to 10 μm are accessible. Single particle based temporal profiles of PAH containing particles ion (size distribution and PAH speciation) have been recorded in Oberschleissheim, Germany from ambient air. Furthermore profiles of relevant emission sources (e

  17. Pulsed, Single-Frequency, 2-um Seed Source for Coherent LIDAR Applications Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The primary objective of the proposed Phase II effort is to develop and deliver a ruggedized, single-frequency, mJ-level, 2050-nm master oscillator power amplifier...

  18. Second-line single-agent chemotherapy in human epidermal growth factor receptor 2-negative metastatic breast cancer: A systematic review.

    Science.gov (United States)

    Puglisi, Fabio; Rea, Daniel; Kroes, Michel A; Pronzato, Paolo

    2016-02-01

    No 'gold standard' exists for single-agent chemotherapy of human epidermal growth factor receptor 2-negative (HER2-negative) metastatic breast cancer (MBC) in the second-line. The objective of this systematic review is to identify and appraise overall survival (OS), progression-free survival (PFS), time to progression (TTP) and Grade ≥3 adverse event evidence for single-agent chemotherapy in this setting. MEDLINE, Embase and the Cochrane Library were searched to October 2013, and PubMed October 2013 to November 2014. Electronic database searches were supplemented with hand searching of reference lists and conferences. Eligible randomised controlled trials (RCTs) employed at least one single-agent chemotherapy treatment, enrolled HER2-negative or unselected MBC patients who had progressed following first-line chemotherapy within the metastatic setting, and reported outcomes of interest for the second-line setting. Fifty-three RCTs were included in total, with most containing mixed populations by HER2 status and treatment line. Fourteen studies reported data specifically for second- and later-line treatment within the metastatic setting. Median overall survival (OS) in most trials was 8-13 months. Only one trial reported a significant difference between studied interventions in the second-line metastatic setting: nab-paclitaxel (n=131) conferred a statistically significant OS advantage vs. three-weekly paclitaxel (n=136) (median OS 13.0 vs. 10.7 months, respectively; hazard ratio 0.73, p=0.024) and improved overall safety. One RCT demonstrated significant benefit in this setting in confirmed HER2-negative MBC alongside favourable safety. Treatment line terminology was imprecise. To reliably inform patient treatment decisions, quality-of-life data are needed and precise OS estimation according to underlying patient characteristics. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. Geolocation of Source Interference from a Single Satellite with Multiple Antennas

    Science.gov (United States)

    2014-03-01

    requiring improvement. Finally, and most significantly, thank you to all of my girls , Jenn, Taylor, Madeline, and Emma, for your unconditional love...transmitter, the gain from the antenna rapidly falls below 16 dB, shown by red contour lines in Figure 100, then comes back above 18 dB (dark orange

  20. The Application of the Theory of Synthesis of a Delay Line with a Surface Acoustic Wave for a Single-Mode Oscillator of Electric Signals in Some Sensors of Non-Electrical Quantities

    Directory of Open Access Journals (Sweden)

    Šimko Milan

    2017-09-01

    Full Text Available The paper deals with the issue of constructing delay lines on the basis of surface acoustic waves and their application to single-mode oscillators. As a result of a theoretical analysis concrete delay lines are proposed.

  1. RNA sequencing for global gene expression associated with muscle growth in a single male modern broiler line compared to a foundational Barred Plymouth Rock chicken line.

    Science.gov (United States)

    Kong, Byung-Whi; Hudson, Nicholas; Seo, Dongwon; Lee, Seok; Khatri, Bhuwan; Lassiter, Kentu; Cook, Devin; Piekarski, Alissa; Dridi, Sami; Anthony, Nicholas; Bottje, Walter

    2017-01-13

    Modern broiler chickens exhibit very rapid growth and high feed efficiency compared to unselected chicken breeds. The improved production efficiency in modern broiler chickens was achieved by the intensive genetic selection for meat production. This study was designed to investigate the genetic alterations accumulated in modern broiler breeder lines during selective breeding conducted over several decades. To identify genes important in determining muscle growth and feed efficiency in broilers, RNA sequencing (RNAseq) was conducted with breast muscle in modern pedigree male (PeM) broilers (n = 6 per group), and with an unselected foundation broiler line (Barred Plymouth Rock; BPR). The RNAseq analysis was carried out using Ilumina Hiseq (2 x 100 bp paired end read) and raw reads were assembled with the galgal4 reference chicken genome. With normalized RPM values, genes showing >10 average read counts were chosen and genes showing 1.3 fold change were considered as differentially expressed (DE) between PeM and BPR. DE genes were subjected to Ingenuity Pathway Analysis (IPA) for bioinformatic functional interpretation. The results indicate that 2,464 DE genes were identified in the comparison between PeM and BPR. Interestingly, the expression of genes encoding mitochondrial proteins in chicken are significantly biased towards the BPR group, suggesting a lowered mitochondrial content in PeM chicken muscles compared to BPR chicken. This result is inconsistent with more slow muscle fibers bearing a lower mitochondrial content in the PeM. The molecular, cellular and physiological functions of DE genes in the comparison between PeM and BPR include organismal injury, carbohydrate metabolism, cell growth/proliferation, and skeletal muscle system development, indicating that cellular mechanisms in modern broiler lines are tightly associated with rapid growth and differential muscle fiber contents compared to the unselected BPR line. Particularly, PDGF (platelet derived

  2. Acquired TGF beta 1 sensitivity and TGF beta 1 expression in cell lines established from a single small cell lung cancer patient during clinical progression

    DEFF Research Database (Denmark)

    Nørgaard, P; Damstrup, L; Rygaard, K

    1996-01-01

    Three small cell lung cancer cell lines established from a single patient during longitudinal follow-up were examined for in vitro expression of TGF beta and TGF beta receptors, i.e. the components of an autocrine loop. GLC 14 was established prior to treatment, GLC 16 on relapse after chemotherapy...... was found in GLC 16 and GLC 19. These cell lines were also growth inhibited by exogenously administrated TGF beta 1. TGF beta 1 mRNA and protein in its latent form was only expressed in the radiotherapy-resistant cell line, GLC 19. The results indicate that disease progression in this patient was paralleled...... II receptor gene, as examined by Southern blotting. Also, the type I receptor could not be detected by ligand binding assay in this cell line, despite expression of mRNA for this receptor. This agrees with previous findings that type I receptor cannot bind TGF beta 1 without co-expression of the type...

  3. Evaluation of thermal properties of food materials at high pressures using a dual-needle line-heat-source method.

    Science.gov (United States)

    Zhu, S; Ramaswamy, H S; Marcotte, M; Chen, C; Shao, Y; Le Bail, A

    2007-03-01

    Thermal properties of food systems at high pressure (HP) are important in the design and operation of HP processing equipment. Available techniques for thermal property evaluation under HP conditions are still very limited. In this study, a dual-needle line-heat-source (DNL) device was installed in an HP vessel to evaluate thermal conductivity (k), diffusivity (alpha), and volumetric heat capacity (C(pV)) of foods at high pressure. The DNL probe was calibrated using glycerin (0.1 MPa) and 2% (w/w) agar gel (0.1 to 350 MPa) at 5 and 25 degrees C. Calibration results showed a good correlation with the reference data of pure water: R(2)= 0.966 for thermal conductivity and R(2)= 0.837 for diffusivity, and a small standard deviation of relative error (3.18%) for the volumetric heat capacity. Fresh potato and cheddar cheese were used as test samples at 5 degrees C at selected pressure levels (0.1 to 350 MPa). The potato samples gave thermal properties very close to those of pure water, but much higher than those of the cheese. The k and alpha values of both potato and cheese increased with pressure and a 2nd-order polynomial well fitted their pressure dependency. The volumetric heat capacity data did not show a clear pressure-dependency trend. The experimental system worked well for the evaluation of thermal properties at pressures up to 350 MPa.

  4. On-Line Desalting of Crude Oil in the Source Region of a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer

    Science.gov (United States)

    Chanthamontri, C. Ken; Stopford, Andrew P.; Snowdon, Ryan W.; Oldenburg, Thomas B. P.; Larter, Stephen R.

    2014-08-01

    The presence of dissolved metal ions in waters associated with crude oils has many negative implications for the transport, processing, and refining of petroleum. In addition, mass spectrometric analysis of sodium containing crude oil samples suffers from ionization suppression, unwanted adduct formation, and an increase in the complexity of data analysis. Here, we describe a method for the reduction/elimination of these adverse effects by modification of the source region gas-inlet system of a 12 T Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. Several acids were examined as part of this study, with the most suitable for on-line desalting found to have both high vapor pressure and low pKa; 12.1 M HCl showed the strongest desalting effect for crude oil samples with a sodium removal index (SRI) of 88%-100% ± 7% for the NaOS compound class. In comparison, a SRI of only 38% ± 9% was observed for a H2O/toluene solution-phase extraction of Oil 1. These results clearly demonstrate the increased efficacy of pseudo-vapor phase desalting with the additional advantages that initial sample solution conditions are preserved and no sample preparation is required prior to analysis.

  5. Effect of Single or Combined Climatic and Hygienic Stress in Four Layer Lines: 2. Endocrine and Oxidative Stress Responses

    NARCIS (Netherlands)

    Star, L.; Decuypere, E.; Parmentier, H.K.; Kemp, B.

    2008-01-01

    Effects of long-term climatic stress (heat exposure), short-term hygienic stress [lipopolysaccharide (LPS)], or combined exposure to these stressors on endocrine and oxidative stress parameters of 4 layer lines (B1, WA, WB, and WF) were investigated. The lines were earlier characterized for natural

  6. Comparing Multipollutant Emissions-Based Mobile Source Indicators to Other Single Pollutant and Multipollutant Indicators in Different Urban Areas

    Directory of Open Access Journals (Sweden)

    Michelle M. Oakes

    2014-11-01

    Full Text Available A variety of single pollutant and multipollutant metrics can be used to represent exposure to traffic pollutant mixtures and evaluate their health effects. Integrated mobile source indicators (IMSIs that combine air quality concentration and emissions data have recently been developed and evaluated using data from Atlanta, Georgia. IMSIs were found to track trends in traffic-related pollutants and have similar or stronger associations with health outcomes. In the current work, we apply IMSIs for gasoline, diesel and total (gasoline + diesel vehicles to two other cities (Denver, Colorado and Houston, Texas with different emissions profiles as well as to a different dataset from Atlanta. We compare spatial and temporal variability of IMSIs to single-pollutant indicators (carbon monoxide (CO, nitrogen oxides (NOx and elemental carbon (EC and multipollutant source apportionment factors produced by Positive Matrix Factorization (PMF. Across cities, PMF-derived and IMSI gasoline metrics were most strongly correlated with CO (r = 0.31–0.98, while multipollutant diesel metrics were most strongly correlated with EC (r = 0.80–0.98. NOx correlations with PMF factors varied across cities (r = 0.29–0.67, while correlations with IMSIs were relatively consistent (r = 0.61–0.94. In general, single-pollutant metrics were more correlated with IMSIs (r = 0.58–0.98 than with PMF-derived factors (r = 0.07–0.99. A spatial analysis indicated that IMSIs were more strongly correlated (r > 0.7 between two sites in each city than single pollutant and PMF factors. These findings provide confidence that IMSIs provide a transferable, simple approach to estimate mobile source air pollution in cities with differing topography and source profiles using readily available data.

  7. Bismuth(III) dialkyldithiophosphates: Facile single source precursors for the preparation of bismuth sulfide nanorods and bismuth phosphate thin films

    International Nuclear Information System (INIS)

    Biswal, Jasmine B.; Garje, Shivram S.; Nuwad, Jitendra; Pillai, C.G.S.

    2013-01-01

    Two different phase pure materials (Bi 2 S 3 and Bi 2 P 4 O 13 ) have been prepared under different conditions using the same single source precursors. Solvothermal decomposition of the complexes, Bi(S 2 P(OR) 2 ) 3 [where, R=Methyl (Me) (1), Ethyl (Et) (2), n-Propyl (Pr n ) (3) and iso-Propyl (Pr i ) (4)] in ethylene glycol gave orthorhombic bismuth sulfide nanorods, whereas aerosol assisted chemical vapor deposition (AACVD) of the same precursors deposited monoclinic bismuth tetraphosphate (Bi 2 P 4 O 13 ) thin films on glass substrates. Surface study of the thin films using SEM illustrated the formation of variety of nanoscale morphologies (spherical-, wire-, pendent-, doughnut- and flower-like) at different temperatures. AFM studies were carried out to evaluate quality of the films in terms of uniformity and roughness. Thin films of average roughness as low as 1.4 nm were deposited using these precursors. Photoluminescence studies of Bi 2 P 4 O 13 thin films were also carried out. - Graphical abstract: Solvothermal decomposition of bismuth(III) dialkyldithiophosphates in ethylene glycol gave Bi 2 S 3 nanoparticles, whereas aerosol assisted chemical vapor deposition of these single source precursors deposited Bi 2 P 4 O 13 thin films. Display Omitted - Highlights: • Preparation of phase pure orthorhombic Bi 2 S 3 nanorods and monoclinic Bi 2 P 4 O 13 thin films. • Use of single source precursors for deposition of bismuth phosphate thin films. • Use of solvothermal decomposition and AACVD methods. • Morphology controlled synthesis of Bi 2 P 4 O 13 thin films. • Bi 2 S 3 nanorods and Bi 2 P 4 O 13 thin films using same single source precursors

  8. jCompoundMapper: An open source Java library and command-line tool for chemical fingerprints

    Directory of Open Access Journals (Sweden)

    Hinselmann Georg

    2011-01-01

    Full Text Available Abstract Background The decomposition of a chemical graph is a convenient approach to encode information of the corresponding organic compound. While several commercial toolkits exist to encode molecules as so-called fingerprints, only a few open source implementations are available. The aim of this work is to introduce a library for exactly defined molecular decompositions, with a strong focus on the application of these features in machine learning and data mining. It provides several options such as search depth, distance cut-offs, atom- and pharmacophore typing. Furthermore, it provides the functionality to combine, to compare, or to export the fingerprints into several formats. Results We provide a Java 1.6 library for the decomposition of chemical graphs based on the open source Chemistry Development Kit toolkit. We reimplemented popular fingerprinting algorithms such as depth-first search fingerprints, extended connectivity fingerprints, autocorrelation fingerprints (e.g. CATS2D, radial fingerprints (e.g. Molprint2D, geometrical Molprint, atom pairs, and pharmacophore fingerprints. We also implemented custom fingerprints such as the all-shortest path fingerprint that only includes the subset of shortest paths from the full set of paths of the depth-first search fingerprint. As an application of jCompoundMapper, we provide a command-line executable binary. We measured the conversion speed and number of features for each encoding and described the composition of the features in detail. The quality of the encodings was tested using the default parametrizations in combination with a support vector machine on the Sutherland QSAR data sets. Additionally, we benchmarked the fingerprint encodings on the large-scale Ames toxicity benchmark using a large-scale linear support vector machine. The results were promising and could often compete with literature results. On the large Ames benchmark, for example, we obtained an AUC ROC performance of 0

  9. A Single Phase Doubly Grounded Semi-Z-Source Inverter for Photovoltaic (PV Systems with Maximum Power Point Tracking (MPPT

    Directory of Open Access Journals (Sweden)

    Tofael Ahmed

    2014-06-01

    Full Text Available In this paper, a single phase doubly grounded semi-Z-source inverter with maximum power point tracking (MPPT is proposed for photovoltaic (PV systems. This proposed system utilizes a single-ended primary inductor (SEPIC converter as DC-DC converter to implement the MPPT algorithm for tracking the maximum power from a PV array and a single phase semi-Z-source inverter for integrating the PV with AC power utilities. The MPPT controller utilizes a fast-converging algorithm to track the maximum power point (MPP and the semi-Z-source inverter utilizes a nonlinear SPWM to produce sinusoidal voltage at the output. The proposed system is able to track the MPP of PV arrays and produce an AC voltage at its output by utilizing only three switches. Experimental results show that the fast-converging MPPT algorithm has fast tracking response with appreciable MPP efficiency. In addition, the inverter shows the minimization of common mode leakage current with its ground sharing feature and reduction of the THD as well as DC current components at the output during DC-AC conversion.

  10. An In Vivo Evaluation of the Fit of Zirconium-Oxide Based, Ceramic Single Crowns with Vertical and Horizontal Finish Line Preparations.

    Science.gov (United States)

    Vigolo, Paolo; Mutinelli, Sabrina; Biscaro, Leonello; Stellini, Edoardo

    2015-12-01

    Different types of tooth preparations influence the marginal precision of zirconium-oxide based ceramic single crowns. In this in vivo study, the marginal fits of zirconium-oxide based ceramic single crowns with vertical and horizontal finish lines were compared. Forty-six teeth were chosen in eight patients indicated for extraction for implant placement. CAD/CAM technology was used for the production of 46 zirconium-oxide-based ceramic single crowns: 23 teeth were prepared with vertical finishing lines, 23 with horizontal finishing lines. One operator accomplished all clinical procedures. The zirconia crowns were cemented with glass ionomer cement. The teeth were extracted 1 month later. Marginal gaps along vertical planes were measured for each crown, using a total of four landmarks for each tooth by means of a microscope at 50× magnification. On conclusion of microscopic assessment, ESEM evaluation was completed on all specimens. The comparison of the gap between the two types of preparation was performed with a nonparametric test (two-sample Wilcoxon rank-sum test) with a level of significance fixed at p crowns with vertical and horizontal finish line preparations were not different. © 2015 by the American College of Prosthodontists.

  11. X-ray diffraction from single molecules at the worlds first X-ray free-electron laser source

    Energy Technology Data Exchange (ETDEWEB)

    Stern, Stephan; Kuepper, Jochen; Chapman, Henry; Rolles, Daniel [Center for Free-Electron Laser Science (CFEL), DESY, Hamburg (Germany)

    2011-07-01

    The advent of the first X-ray Free-Electron Laser, the Linac Coherent Light Source (LCLS), opens up a new approach for diffractive imaging of even single molecules that cannot be crystallized into macromolecular crystals of sufficient size necessary for conventional X-ray crystallography. Here, we present the concept, the experimental parametric space that has to be addressed together with first experimental results of X-ray diffractive imaging of single molecules in the gas phase at LCLS. We use a supersonically cooled molecular beam to provide an ensemble of test-molecules, laser-align them, and subsequently probe them with the LCLS in order to get diffraction patterns of single molecules.

  12. Extrusion of single-wall carbon nanotubes via formation of small particles condensed near an arc evaporation source

    Science.gov (United States)

    Saito, Yahachi; Okuda, Mitsumasa; Tomita, Masato; Hayashi, Takayoshi

    1995-04-01

    Single-wall (SW) tubes were produced by co-evaporation of carbon and lanthanum in helium gas and examined by transmission electron microscopy (TEM). TEM samples were collected directly from a space near the arc evaporation source during evaporation. SW tubes growing radially from compound particles were observed 4 cm above the source, but not 2 cm. The 'sea urchin'-like morphology of these tubes were similar to those observed for soot deposited on the inner walls of the reaction chamber, suggesting that soot particles were formed first in the gas phase and SW tubes grew from them before deposition on the chamber wall. The temperature distribution and flow velocity of convection around the source are used for discussion of the growth mechanism of the SW tubes.

  13. Controlling single and few-layer graphene crystals growth in a solid carbon source based chemical vapor deposition

    International Nuclear Information System (INIS)

    Papon, Remi; Sharma, Subash; Shinde, Sachin M.; Vishwakarma, Riteshkumar; Tanemura, Masaki; Kalita, Golap

    2014-01-01

    Here, we reveal the growth process of single and few-layer graphene crystals in the solid carbon source based chemical vapor deposition (CVD) technique. Nucleation and growth of graphene crystals on a polycrystalline Cu foil are significantly affected by the injection of carbon atoms with pyrolysis rate of the carbon source. We observe micron length ribbons like growth front as well as saturated growth edges of graphene crystals depending on growth conditions. Controlling the pyrolysis rate of carbon source, monolayer and few-layer crystals and corresponding continuous films are obtained. In a controlled process, we observed growth of large monolayer graphene crystals, which interconnect and merge together to form a continuous film. On the other hand, adlayer growth is observed with an increased pyrolysis rate, resulting few-layer graphene crystal structure and merged continuous film. The understanding of monolayer and few-layer crystals growth in the developed CVD process can be significant to grow graphene with controlled layer numbers.

  14. Sources of variability in OSL dose measurements using single grains of quartz

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov; Murray, A.S.; Bøtter-Jensen, L.

    2005-01-01

    spread. In this preliminary study, dose distributions have been studied using single grains of heated and laboratory irradiated quartz. By heating the sample, the contribution from incomplete zeroing was excluded and at the same time the sample was sensitised. The laboratory gamma irradiation...

  15. Near-unity efficiency, single-photon sources based on tapered photonic nanowires

    DEFF Research Database (Denmark)

    Bleuse, Joël; Munsch, Mathieu; Claudon, Julien

    2012-01-01

    Single-photon emission from excitons in InAs Quantum Dots (QD) embedded in GaAs Tapered Photonic Wires (TPW) already demonstrated a 0.72 collection efficiency, with TPWs were the apex is the sharp end of the cone. Going to alternate designs, still based on the idea of the adiabatic deconfinement...

  16. Fundamental limitations in spontaneous emission rate of single-photon sources

    DEFF Research Database (Denmark)

    Bozhevolnyi, Sergey I.; Khurgin, Jacob B.

    2016-01-01

    The rate of single-photon generation by quantum emitters (QEs) can be enhanced by placing a QE inside a resonant structure. This structure can represent an all-dielectric micro-resonator or waveguide and thus be characterized by ultra-low loss and dimensions on the order of wavelength. Or it can ...

  17. Sources

    International Nuclear Information System (INIS)

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  18. Photocatalytic applications of Cr{sub 2}S{sub 3} synthesized from single and multi-source precursors

    Energy Technology Data Exchange (ETDEWEB)

    Hussain, Wajid [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan); Badshah, Amin, E-mail: aminbadshah@qau.edu.pk [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan); Hussain, Raja Azadar; Imtiaz-ud-Din [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan); Aleem, Muhammad Adeel [The Pakistan Institute of Engineering and Applied Sciences (PIEAS) (Pakistan); Bahadur, Ali [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan); Iqbal, Shahid [School of Chemistry and Chemical Engineering, University of Chinese Academy of Sciences, Beijing, 100049 (China); Farooq, Muhammad Umar; Ali, Hassan [Department of Chemistry, Quaid-i-Azam University, 45320, Islamabad (Pakistan)

    2017-06-15

    Most of the material research work is pertinent to the synthesis of transition-metal sulfides nanoparticles but here the studies are limited to the synthesis of chromium sulfide. However, the preparation method, presented in this work, may be extended to other metal chalcogenides nanoparticles for various potential applications. The ligand (precursor), 1-(2-chloro-4-nitrophenyl)-3,3-chlorobenzoyl and Cr{sub 2}S{sub 3} have been synthesized initially from single source precursor and then from multi source precursors. The target was to alter the morphologies of nanomaterial while altering the synthetic route and that was successfully achieved. Chromium sulfide nano-rods were synthesized using single source precursors while nanoparticles were fabricated using multi source precursors. Characterization were carried out through {sup 1}H and {sup 13}C NMR, scanning electron microscopy (SEM), transmission electron microscopy (TEM), powder X-ray diffraction microscopy (PXRD), energy dispersive X-ray spectroscopy (EDX), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS) and high resolution transmission electron microscopy (HRTEM). Our objective is to change the morphologies by changing the synthetic route so that is why further applications were done only for multi-source product, denying single source product. The metal sulfides nanoparticles exhibit higher activity than their bulk material for the photocatalytic degradation of organic dyes under visible-light irradiation. So, photocatalytic activity was successfully achieved under direct sunlight against five different cationic and anionic organic dyes including malachite green (MG), methylene blue (MB), rhodamine B (RhB), methyl violet (MV) and methyl orange (MO). These organic dyes MV, MG, MB, and RB were almost diminished or decolorized by Cr{sub 2}S{sub 3} within 110, 90, 100, and 130, minutes, respectively expect MO. - Highlights: • Synthesis of Cr{sub 2}S{sub 3} from single and multisource precursors is

  19. Designs for high-efficiency electrically pumped photonic nanowire single-photon sources

    DEFF Research Database (Denmark)

    Gregersen, Niels; Nielsen, Torben Roland; Mørk, Jesper

    2010-01-01

    to conventional cavity-based sources, this non-resonant approach provides broadband spontaneous emission control and features an improved fabrication tolerance towards surface roughness and imperfections. Using an element-splitting approach, we analyze the various building blocks of the designs with respect...... to realistic variations of the experimental fabrication parameters....

  20. 78 FR 27240 - Announcing the Award of a New Single-Source Award to the National Council on Family Violence in...

    Science.gov (United States)

    2013-05-09

    ....095] Announcing the Award of a New Single-Source Award to the National Council on Family Violence in... single-source cooperative agreement to the National Council on Family Violence to support the National Domestic Violence Hotline (Hotline). SUMMARY: The Administration for Children and Families (ACF...

  1. Intermediate-mass single stars and accreting white dwarfs as sources of neutron-rich isotopes

    International Nuclear Information System (INIS)

    Iben, I. Jr.

    1981-01-01

    During the most luminous portion of the asymptotic giant-branch phase, models of intermediate-mass stars first become carbon stars and then produce s-process isotopes in the solar-system distribution. Recent observations of the optically most luminous carbon stars in the Magellanic Clouds introduce the possibility that real intermediate-mass stars lose their hydrogen-rich envelopes during the asymptotic giant-branch phase before they have made s-process isotopes both in large quantities and in the solar system distribution. This encourages a search for alternate sources of these isotopes. A promising site for the production of some neutron-rich isotopes isthe convective helium-carbon region that appears in accreting white dwarfs during helium shell flashes. For appropriate accretion rates, overlap of matter in successive convective zones may lead to an exponential distribution of exposures. Further, because of a small entropy barrier between the convective shell and the hydrogen-rich envelope, protons enter the shell and provide a source of neutrons that, for appropriate accretion rates, is repetitive in strength and either dominates or is complementary to the 22 Ne(α,n) 25 Mg source. This permits an estimate of the distribution of neutron-rich isotopes that is formed after many flashes. The distribution, in most instances, tends to be weighted more toward heavier elements than is the case when 22 Ne(α, n) 25 Mg is the sole source of neutrons. Hence, accreting white dwarfs cannot be major contributors to the enrichment of the interstellar medium in most s-process isotopes. Considerable effort should be devoted toward demonstrating whether or not the bolometrically most lumious asymptotic giant branch stars in local systems obey M/sub BOL/ /sup min/ -6.5, then either the source of most Galactic s-process isotopes is as yet unknown, or the rate of the 22 Ne(α, n) 25 Mg reaction has been underestimated

  2. A NLTE line formation for neutral and singly-ionised calcium in model atmospheres of B-F stars

    Science.gov (United States)

    Sitnova, T. M.; Mashonkina, L. I.; Ryabchikova, T. A.

    2018-03-01

    We present non-local thermodynamic equilibrium (NLTE) line formation calculations for Ca I and Ca II in B-F stars. The sign and the magnitude of NLTE abundance corrections depend on line and stellar parameters. We determine calcium abundances for nine stars with reliable stellar parameters. For all stars, where the lines of both species could be measured, the NLTE abundances are found to be consistent within the error bars. We obtain consistent NLTE abundances from Ca II lines in the visible and near infra-red (IR, 8912-27, 9890 Å) spectrum range, in contrast with LTE, where the discrepancy between the two groups of lines ranges from -0.5 dex to 0.6 dex for different stars. Our NLTE method reproduces the Ca II 8912-27, 9890 Å lines observed in emission in the late B-type star HD 160762 with the classical plane-parallel and LTE model atmosphere. NLTE abundance corrections for lines of Ca I and Ca II were calculated in a grid of model atmospheres with 7000 K ≤ Teff ≤ 13000 K, 3.2 ≤ log g ≤ 5.0, -0.5 ≤ [Fe/H] ≤0.5, ξt= 2.0 km s-1. Our NLTE results can be applied for calcium NLTE abundance determination from Gaia spectra, given that accurate continuum normalisation and proper treatment of the hydrogen Paschen lines are provided. The NLTE method can be useful to refine calcium underabundances in Am stars and to provide accurate observational constraints on the models of diffusion.

  3. Multiple-output microwave single-photon source using superconducting circuits with longitudinal and transverse couplings

    Science.gov (United States)

    Wang, Xin; Miranowicz, Adam; Li, Hong-Rong; Nori, Franco

    2016-11-01

    Single-photon devices at microwave frequencies are important for applications in quantum information processing and communication in the microwave regime. In this work we describe a proposal of a multioutput single-photon device. We consider two superconducting resonators coupled to a gap-tunable qubit via both its longitudinal and transverse degrees of freedom. Thus, this qubit-resonator coupling differs from the coupling in standard circuit quantum-electrodynamic systems described by the Jaynes-Cummings model. We demonstrate that an effective quadratic coupling between one of the normal modes and the qubit can be induced and this induced second-order nonlinearity is much larger than that for conventional Kerr-type systems exhibiting photon blockade. Assuming that a coupled normal mode is resonantly driven, we observe that the output fields from the resonators exhibit strong sub-Poissonian photon-number statistics and photon antibunching. Contrary to previous studies on resonant photon blockade, the first-excited state of our device is a pure single-photon Fock state rather than a polariton state, i.e., a highly hybridized qubit-photon state. In addition, it is found that the optical state truncation caused by the strong qubit-induced nonlinearity can lead to an entanglement between the two resonators, even in their steady state under the Markov approximation.

  4. Phonon scattering inhibits simultaneous near-unity efficiency and indistinguishability in semiconductor single-photon sources

    DEFF Research Database (Denmark)

    Iles-Smith, Jake; McCutcheon, Dara P. S.; Nazir, Ahsan

    2017-01-01

    Semiconductor quantum dots (QDs) have recently emerged as a leading platform to generate highly indistinguishable photons efficiently, and this work addresses the timely question of how good these solid-state sources can ultimately be. We establish the crucial role of lattice relaxation in these ......Semiconductor quantum dots (QDs) have recently emerged as a leading platform to generate highly indistinguishable photons efficiently, and this work addresses the timely question of how good these solid-state sources can ultimately be. We establish the crucial role of lattice relaxation...... relationship, in which indistinguishability and efficiency cannot be simultaneously increased. For cavities, the frequency selectivity of the Purcell enhancement results in a more subtle trade-off, in which indistinguishability and efficiency can be increased simultaneously, although not arbitrarily, which...

  5. Analysis of the Propagation Characteristics of Ultrasonic Guided Waves Excited by Single Frequency and Broadband Sources

    Energy Technology Data Exchange (ETDEWEB)

    Kang, To; Song, Sung Jin; Kim, Hark Joon [Sungkyunkwan University, Suwon (Korea, Republic of); Cho, Young Do; Lee, Dong Hoon [Korea Gas Safety Corporation, Seongnam (Korea, Republic of); Cho, Hyun Joon [Advanced Institute of Quality and Safety, Uiwang (Korea, Republic of)

    2009-12-15

    Excitation and propagation of guided waves are very complex problems in pipes due to their dispersive nature. Pipes are commonly used in the oil, chemical or nuclear industry and hence must be inspected regularly to ensure continued safe operation. The normal mode expansion(NME) method is given for the amplitude with which any propagating waveguide mode is generated in the pipes by applied surface tractions. Numerical results are calculated based on the NME method using different sources, i.e., non-axisymmetric partial loading and quasi-axisymmetric loading sources. The sum of amplitude coefficients for 0{approx}ninth order of the harmonic modes are calculated based on the NME method and the dispersion curves in pipes. The superimposed total field which is namely the angular profile, varies with propagating distance and circumferential angle. This angular profile of guided waves provides information for setting the transducer position to find defects in pipes.

  6. Optimization of ECR singly-charged ion sources for the radioactive ion beam production

    CERN Document Server

    Jardin, P; Gaubert, G; Pacquet, J Y; Drobert, T; Cornell, J; Barue, C; Canet, C; Dupuis, M; Flambard, J L; Lecesne, N; Leherissier, P; Lemagnen, F; Leroy, R

    2003-01-01

    Measurements of the transformation time of atoms into ions were carried out with two 2.45 GHz electron cyclotron resonance ion sources (ECRIS) in the case of the simple ionization of He, Ne, Ar and Kr gases. The effect of the plasma volume, of the dead volumes and of the ionization efficiency are presented. Some rules are deduced for the design of the next ECRIS dedicated to radioactive ion production with noble gases.

  7. Fast computation of quadrupole and hexadecapole approximations in microlensing with a single point-source evaluation

    Science.gov (United States)

    Cassan, Arnaud

    2017-07-01

    The exoplanet detection rate from gravitational microlensing has grown significantly in recent years thanks to a great enhancement of resources and improved observational strategy. Current observatories include ground-based wide-field and/or robotic world-wide networks of telescopes, as well as space-based observatories such as satellites Spitzer or Kepler/K2. This results in a large quantity of data to be processed and analysed, which is a challenge for modelling codes because of the complexity of the parameter space to be explored and the intensive computations required to evaluate the models. In this work, I present a method that allows to compute the quadrupole and hexadecapole approximations of the finite-source magnification with more efficiency than previously available codes, with routines about six times and four times faster, respectively. The quadrupole takes just about twice the time of a point-source evaluation, which advocates for generalizing its use to large portions of the light curves. The corresponding routines are available as open-source python codes.

  8. Single-particle and collective properties around closed shells probed by in-source laser spectroscopy

    CERN Document Server

    Cocolios, Thomas Elias; Van Duppen, P

    2010-01-01

    Resonant laser ionisation is a very versatile tool in nuclear physics, used for the production of clean radioactive ion beams as well as for the study of ground-state and isomer properties. In this Ph.D. work, many aspects of resonant laser ionisation are investigated, from improving the performance of laser ion sources at ISOL facilities to the measurement of magnetic dipole moments and charge radii. The LISOL gas catcher ion source relies on resonant laser ionisation for increased efficiency and selectivity. Using a $^{252}$Cf fission source, the element dependence of the non-resonant contribution to the ion beam has been investigated. The efficiency of extraction for a non-laser-ionised element ranges from 0.03% for krypton to 74% for ceasium. A relationship with the ionisation potential is proposed, although a few elements like rubidium and cerium do not verify this relationship. In order to suppress those non-resonantly-ionised elements, two new approaches are proposed. First, the dual-chamber gas catche...

  9. Optimization of cell line development in the GS-CHO expression system using a high-throughput, single cell-based clone selection system.

    Science.gov (United States)

    Nakamura, Tsuyoshi; Omasa, Takeshi

    2015-09-01

    Therapeutic antibodies are commonly produced by high-expressing, clonal and recombinant Chinese hamster ovary (CHO) cell lines. Currently, CHO cells dominate as a commercial production host because of their ease of use, established regulatory track record, and safety profile. CHO-K1SV is a suspension, protein-free-adapted CHO-K1-derived cell line employing the glutamine synthetase (GS) gene expression system (GS-CHO expression system). The selection of high-producing mammalian cell lines is a crucial step in process development for the production of therapeutic antibodies. In general, cloning by the limiting dilution method is used to isolate high-producing monoclonal CHO cells. However, the limiting dilution method is time consuming and has a low probability of monoclonality. To minimize the duration and increase the probability of obtaining high-producing clones with high monoclonality, an automated single cell-based clone selector, the ClonePix FL system, is available. In this study, we applied the high-throughput ClonePix FL system for cell line development using CHO-K1SV cells and investigated efficient conditions for single cell-based clone selection. CHO-K1SV cell growth at the pre-picking stage was improved by optimizing the formulation of semi-solid medium. The efficiency of picking and cell growth at the post-picking stage was improved by optimization of the plating time without decreasing the diversity of clones. The conditions for selection, including the medium formulation, were the most important factors for the single cell-based clone selection system to construct a high-producing CHO cell line. Copyright © 2015 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  10. Noise-tolerance analysis for detection and reconstruction of absorbing inhomogeneities with diffuse optical tomography using single- and phase-correlated dual-source schemes

    International Nuclear Information System (INIS)

    Kanmani, B; Vasu, R M

    2007-01-01

    An iterative reconstruction procedure is used to invert intensity data from both single- and phase-correlated dual-source illuminations for absorption inhomogeneities. The Jacobian for the dual source is constructed by an algebraic addition of the Jacobians estimated for the two sources separately. By numerical simulations, it is shown that the dual-source scheme performs superior to the single-source system in regard to (i) noise tolerance in data and (ii) ability to reconstruct smaller and lower contrast objects. The quality of reconstructions from single-source data, as indicated by mean-square error at convergence, is markedly poorer compared to their dual-source counterpart, when noise in data was in excess of 2%. With fixed contrast and decreasing inhomogeneity diameter, our simulations showed that, for diameters below 7 mm, the dual-source scheme has a higher percentage contrast recovery compared to the single-source scheme. Similarly, the dual-source scheme reconstructs to a higher percentage contrast recovery from lower contrast inhomogeneity, in comparison to the single-source scheme

  11. Low-power-consumption flat-panel light-emitting device driven by field-emission electron source using high-crystallinity single-walled carbon nanotubes

    Science.gov (United States)

    Shimoi, Norihiro; Abe, Daisuke; Matsumoto, Kazuyuki; Sato, Yoshinori; Tohji, Kazuyuki

    2017-06-01

    Thin electrode films assembled through a wet process using single-walled carbon nanotubes (SWCNTs) are expected to play a role in reducing power consumption and saving energy in field-emission electron sources. The flat-panel light-emitting device for this study featured a line-sequential-scanning-type electrode structure equipped with electrodes for on-and-off controls of electron emissions, on which high-crystallinity SWCNTs were uniformly distributed. The device successfully emitted electrons on the flat panel in a stable manner. A technology for amplifying the luminance output by controlling the persistence characteristics of a fluorescent screen was also successfully developed. By combining such elemental technologies, a flat-panel light-emission device, as a stand-alone planar lighting device, which achieves a high-luminance efficiency of 87 lm/W and energy-conserved driving, was assembled for the first time in the world. The creation of field-emission electron sources driven with ultralow power consumption, along with applications that utilize such devices, is expected in the future.

  12. Online Characterisation of Mineral Dust Aerosol by Single Particle Mass Spectrometry: Mineralogical Signatures of Potential Source Areas in North Africa.

    Science.gov (United States)

    Marsden, N. A.; Allan, J. D.; Flynn, M.; Ullrich, R.; Moehler, O.; Coe, H.

    2017-12-01

    The mineralogy of individual dust particles is important for atmospheric processes because mineralogy influences optical properties, their potential to act as ice nucleating particles (INP) and geochemical cycling of elements to the ocean. Bulk mineralogy of transported mineral dust has been shown to be a reflection of the source area and size fractionation during transport. Online characterisation of single particle mineralogy is highly desirable as the composition of individual particles can be reported at a temporal resolution that is relevant to atmospheric processes. Single particle mass spectrometry (SPMS) has indentified and characterised the composition of ambient dust particles but is hampered by matrix effects that result in a non-quantatative measurement of composition. The work presented describes a comparison of mass spectral characteristics of sub 2.5μm particle fractions generated from; i) nominally pure samples from the clay mineral society (CMS), ii) soil samples collected from potential source areas in North Africa and iii) ambient measurement of transported African dust made at the Cape Verde Islands. Using a novel approach to analyse the mass spectra, the distinct characteristics of the various dust samples are obtained from the online measurements. Using this technique it was observed that dust generated from sources on the North West Margin of the Sahara Desert have distinct characteristics of illite in contrast to the kaolinitic characteristics of dust generated from sources in the Sahel. These methods offer great potential for describing the hourly variation in the source and mineralogy of transported mineral dust and the online differentiation of mineral phase in multi-mineralic dust samples.

  13. Single liquid source plasma enhanced metalorganic chemical vapor deposition of YBa2Cu3O(7-x) thin films

    Science.gov (United States)

    Zhang, Jiming; Gardiner, Robin; Kirlin, Peter S.; Boerstler, Robert W.; Steinbeck, John

    1992-07-01

    High quality YBa2Cu3O(7-x) films were grown in-situ on LaAlO3 (100) by a novel single liquid source plasma-enhanced metalorganic chemical vapor deposition process. The metalorganic complexes M(thd)(sub n), (thd = 2,2,6,6-tetramethyl-3,5-heptanedionate; M = Y, Ba, Cu) were dissolved in an organic solution and injected into a vaporizer immediately upstream of the reactor inlet. The single liquid source technique dramatically simplifies current CVD processing and can significantly improve the process reproducibility. X-ray diffraction. measurements indicated that single phase, highly c-axis oriented YBa2Cu3O(7-x) was formed in-situ at a substrate temperature 680 C. The as-deposited films exhibited a mirror-like surface, had transition temperature T(sub c0) approximately equal to 89 K, Delta T(sub c) less than 1 K, and Jc (77 K) = 10(exp 6) A/sq cm.

  14. Development of a detector setup based on BGO single crystals to measure high energy gamma spectra of neutron sources

    International Nuclear Information System (INIS)

    Tyagi, M.; Singh, S.G.; Singh, A.K.; Desai, D.G.; Tiwari, B.; Sen, S.; Gadkari, S.C.; Ghodke, S.S.; Sujatha, P.N.

    2014-01-01

    Radiation detectors based on Bi 4 Ge 3 O 12 (BGO) single crystal scintillators have many applications, mainly in high-energy physics, and nuclear industry. The BGO possesses several advantages including high density, large effective atomic number Z eff , small radiation length, high radiation hardness, stability of chemical properties, non-hygroscopic nature and much smaller afterglow which make these crystals indispensable in many applications. These crystals are the best choices for the spectroscopy of high energies gamma rays which are usually produced from (γ, n) reactions in various neutron sources. The major applications of these crystals in high energy physics and to detect high energy gammas require large size crystals. It has been well known that the signal output from BGO crystals is strongly governed by the purity and crystal defects. To grow high quality single crystals with large size and minimum number of defects has always been a daunting task for crystal growers. In this communication, we describe the growth and characterization BGO single crystals. Fabrication of a setup based on BGO scintillator useful to measure gamma-rays from an Am-Be neutron source is discussed

  15. Limits on the heralding efficiencies and spectral purities of spectrally filtered single photons from photon-pair sources

    Science.gov (United States)

    Meyer-Scott, Evan; Montaut, Nicola; Tiedau, Johannes; Sansoni, Linda; Herrmann, Harald; Bartley, Tim J.; Silberhorn, Christine

    2017-06-01

    Photon pairs produced by parametric down-conversion or four-wave mixing can interfere with each other in multiport interferometers or carry entanglement between distant nodes for use in entanglement swapping. This requires the photons to be spectrally pure to ensure good interference and have high heralding efficiency to know accurately the number of photons involved and to maintain high rates as the number of photons grows. Spectral filtering is often used to remove noise and define spectral properties. For heralded single photons high purity and heralding efficiency are possible by filtering the heralding arm, but when both photons in typical pair sources are filtered, we show that the heralding efficiency of one or both of the photons is strongly reduced even by ideal spectral filters with 100% transmission in the passband: any improvement in reduced-state spectral purity from filtering comes at the cost of lowered heralding efficiency. We consider the fidelity to a pure, lossless single photon, symmetrize it to include both photons of the pair, and show this quantity is intrinsically limited for sources with spectral correlation. We then provide a framework for this effect for benchmarking common photon-pair sources and present an experiment where we vary the photon filter bandwidths and measure the increase in purity and corresponding reduction in heralding efficiency.

  16. Imaging dipole flow sources using an artificial lateral-line system made of biomimetic hair flow sensors

    NARCIS (Netherlands)

    Dagamseh, A.M.K.; Wiegerink, Remco J.; Lammerink, Theodorus S.J.; Krijnen, Gijsbertus J.M.

    2013-01-01

    In Nature, fish have the ability to localize prey, school, navigate, etc., using the lateral-line organ. Artificial hair flow sensors arranged in a linear array shape (inspired by the lateral-line system (LSS) in fish) have been applied to measure airflow patterns at the sensor positions. Here, we

  17. Splenectomy vs. rituximab as a second-line therapy in immune thrombocytopenic purpura: a single center experience.

    Science.gov (United States)

    Al Askar, Ahmed S; Shaheen, Naila A; Al Zahrani, Mohsen; Al Otaibi, Mohammed G; Al Qahtani, Bader S; Ahmed, Faris; Al Zughaibi, Mohand; Kamran, Ismat; Mendoza, May Anne; Khan, Altaf

    2018-01-01

    Immune thrombocytopenic purpura (ITP) is a common hematological disease treated primarily by corticosteroids. The aim of the present study was to compare response rate between patients, underwent splenectomy vs. rituximab as second-line therapy. Adult patients diagnosed with ITP who did not respond to corticosteroids or relapsed during the period 1990-2014 were included in a quasi-experimental study. Categorical variables were compared using Fisher exact test. Response to treatment was compared using logistic regression. Data were analyzed using SAS V9.2. One-hundred and forty-three patients with ITP were identified through medical records. Of 62 patients treated, 30 (48.38%) required second-line therapy. 19 (63%) patients received rituximab, and 11 (37%) underwent splenectomy. Platelets at diagnosis were not different between study groups (p = 0.062). Splenectomy group patients were younger (p = 0.011). Response to second-line therapy showed no significant difference between two groups (OR 2.03, 95% CI (0.21-22.09), p = 0.549). Results did not show a statistically significant difference in platelet counts over time between treatment groups (p = 0.101). When used exclusively as a second-line therapy for steroid-refractory ITP, the response rate was not statistically different between rituximab and splenectomy. However, further large studies are needed to assess the response rates for these treatment modalities as a second-line therapy.

  18. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  19. Sources of variability for the single-comparator method in a heavy-water reactor

    International Nuclear Information System (INIS)

    Damsgaard, E.; Heydorn, K.

    1978-11-01

    The well thermalized flux in the heavy-water-moderated DR 3 reactor at Risoe prompted us to investigate to what extent a single comparator could be used for multi-element determination instead of multiple comparators. The reliability of the single-comparator method is limited by the thermal-to-epithermal ratio, and experiments were designed to determine the variations in this ratio throughout a reactor operating period (4 weeks including a shut-down period of 4-5 days). The bi-isotopic method using zirconium as monitor was chosen, because 94 Zr and 96 Zr exhibit a large difference in their Isub(o)/Σsub(th) values, and would permit determination of the flux ratio with a precision sufficient to determine variations. One of the irradiation facilities comprises a rotating magazine with 3 channels, each of which can hold five aluminium cans. In this rig, five cans, each holding a polyvial with 1 ml of aqueous zirconium solution were irradiated simultaneously in one channel. Irradiations were carried out in the first and the third week of 4 periods. In another facility consisting of a pneumatic tube system, two samples were simultaneously irradiated on top of each other in a polyethylene rabbit. Experiments were carried out once a week for 4 periods. All samples were counted on a Ge(Li)-detector for 95 Zr, 97 sup(m)Nb and 97 Nb. The thermal-to-epithermal flux ratio was calculated from the induced activity, the nuclear data for the two zirconium isotopes and the detector efficiency. By analysis of variance the total variation of the flux ratio was separated into a random variation between reactor periods, and systematic differences between the positions, as well as the weeks in the operating period. If the variations are in statistical control, the error resulting from use of the single-comparator method in multi-element determination can be estimated for any combination of irradiation position and day in the operating period. With the measure flux ratio variations in DR

  20. Phonon limit to simultaneous near-unity efficiency and indistinguishability in semiconductor single photon sources

    DEFF Research Database (Denmark)

    McCutcheon, Dara P. S.; Iles-Smith, Jake; Nazir, Ahsan

    2016-01-01

    in giving rise to trade-offs between indistinguishability and efficiency. We analyse the two source architectures most commonly employed: a quantum dot embedded in a waveguide and a quantum dot coupled to an optical cavity. For waveguides, we demonstrate that the broadband Purcell effect results in a simple...... inverse relationship, where indistinguishability and efficiency cannot be simultaneously increased. For cavities, the frequency selectivity of the Purcell enhancement results in a more subtle trade-off, where indistinguishability and efficiency can be simultaneously increased, though by the same mechanism...

  1. Alcoa Massena Modernization Project and Request for a Single Source Determination

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  2. Single Source Applicability Determination for Environmental Wood Supply, LLC and District Energy St. Paul, Inc

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  3. Single Source Evaluation for the Hartford Working Group and Premcor Distribution Center

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  4. PSD Applicability Determination for Multiple Owner/Operator Point Sources Within a Single Facility

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  5. BP American Production Company's Florida River Compression Facility Single Source Determination

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  6. Single Source Determination for Gallitan Steel Co. and Heckett MultiServ

    Science.gov (United States)

    This document may be of assistance in applying the New Source Review (NSR) air permitting regulations including the Prevention of Significant Deterioration (PSD) requirements. This document is part of the NSR Policy and Guidance Database. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  7. Molecular characterization of diverse CIMMYT maize inbred lines from eastern and southern Africa using single nucleotide polymorphic markers.

    Science.gov (United States)

    Semagn, Kassa; Magorokosho, Cosmos; Vivek, Bindiganavile S; Makumbi, Dan; Beyene, Yoseph; Mugo, Stephen; Prasanna, B M; Warburton, Marilyn L

    2012-03-25

    Knowledge of germplasm diversity and relationships among elite breeding materials is fundamentally important in crop improvement. We genotyped 450 maize inbred lines developed and/or widely used by CIMMYT breeding programs in both Kenya and Zimbabwe using 1065 SNP markers to (i) investigate population structure and patterns of relationship of the germplasm for better exploitation in breeding programs; (ii) assess the usefulness of SNPs for identifying heterotic groups commonly used by CIMMYT breeding programs; and (iii) identify a subset of highly informative SNP markers for routine and low cost genotyping of CIMMYT germplasm in the region using uniplex assays. Genetic distance for about 94% of the pairs of lines fell between 0.300 and 0.400. Eighty four percent of the pairs of lines also showed relative kinship values ≤ 0.500. Model-based population structure analysis, principal component analysis, neighbor-joining cluster analysis and discriminant analysis revealed the presence of 3 major groups and generally agree with pedigree information. The SNP markers did not show clear separation of heterotic groups A and B that were established based on combining ability tests through diallel and line x tester analyses. Our results demonstrated large differences among the SNP markers in terms of reproducibility, ease of scoring, polymorphism, minor allele frequency and polymorphic information content. About 40% of the SNPs in the multiplexed chip-based GoldenGate assays were found to be uninformative in this study and we recommend 644 of the 1065 for low to medium density genotyping in tropical maize germplasm using uniplex assays. There were high genetic distance and low kinship coefficients among most pairs of lines, clearly indicating the uniqueness of the majority of the inbred lines in these maize breeding programs. The results from this study will be useful to breeders in selecting best parental combinations for new breeding crosses, mapping population development

  8. Molecular characterization of diverse CIMMYT maize inbred lines from eastern and southern Africa using single nucleotide polymorphic markers

    Directory of Open Access Journals (Sweden)

    Semagn Kassa

    2012-03-01

    Full Text Available Abstract Background Knowledge of germplasm diversity and relationships among elite breeding materials is fundamentally important in crop improvement. We genotyped 450 maize inbred lines developed and/or widely used by CIMMYT breeding programs in both Kenya and Zimbabwe using 1065 SNP markers to (i investigate population structure and patterns of relationship of the germplasm for better exploitation in breeding programs; (ii assess the usefulness of SNPs for identifying heterotic groups commonly used by CIMMYT breeding programs; and (iii identify a subset of highly informative SNP markers for routine and low cost genotyping of CIMMYT germplasm in the region using uniplex assays. Results Genetic distance for about 94% of the pairs of lines fell between 0.300 and 0.400. Eighty four percent of the pairs of lines also showed relative kinship values ≤ 0.500. Model-based population structure analysis, principal component analysis, neighbor-joining cluster analysis and discriminant analysis revealed the presence of 3 major groups and generally agree with pedigree information. The SNP markers did not show clear separation of heterotic groups A and B that were established based on combining ability tests through diallel and line x tester analyses. Our results demonstrated large differences among the SNP markers in terms of reproducibility, ease of scoring, polymorphism, minor allele frequency and polymorphic information content. About 40% of the SNPs in the multiplexed chip-based GoldenGate assays were found to be uninformative in this study and we recommend 644 of the 1065 for low to medium density genotyping in tropical maize germplasm using uniplex assays. Conclusions There were high genetic distance and low kinship coefficients among most pairs of lines, clearly indicating the uniqueness of the majority of the inbred lines in these maize breeding programs. The results from this study will be useful to breeders in selecting best parental combinations

  9. Single-exposure two-dimensional superresolution in digital holography using a vertical cavity surface-emitting laser source array.

    Science.gov (United States)

    Granero, Luis; Zalevsky, Zeev; Micó, Vicente

    2011-04-01

    We present a new implementation capable of producing two-dimensional (2D) superresolution (SR) imaging in a single exposure by aperture synthesis in digital lensless Fourier holography when using angular multiplexing provided by a vertical cavity surface-emitting laser source array. The system performs the recording in a single CCD snapshot of a multiplexed hologram coming from the incoherent addition of multiple subholograms, where each contains information about a different 2D spatial frequency band of the object's spectrum. Thus, a set of nonoverlapping bandpass images of the input object can be recovered by Fourier transformation (FT) of the multiplexed hologram. The SR is obtained by coherent addition of the information contained in each bandpass image while generating an enlarged synthetic aperture. Experimental results demonstrate improvement in resolution and image quality.

  10. Combined EEG/MEG can outperform single modality EEG or MEG source reconstruction in presurgical epilepsy diagnosis.

    Directory of Open Access Journals (Sweden)

    Ümit Aydin

    Full Text Available We investigated two important means for improving source reconstruction in presurgical epilepsy diagnosis. The first investigation is about the optimal choice of the number of epileptic spikes in averaging to (1 sufficiently reduce the noise bias for an accurate determination of the center of gravity of the epileptic activity and (2 still get an estimation of the extent of the irritative zone. The second study focuses on the differences in single modality EEG (80-electrodes or MEG (275-gradiometers and especially on the benefits of combined EEG/MEG (EMEG source analysis. Both investigations were validated with simultaneous stereo-EEG (sEEG (167-contacts and low-density EEG (ldEEG (21-electrodes. To account for the different sensitivity profiles of EEG and MEG, we constructed a six-compartment finite element head model with anisotropic white matter conductivity, and calibrated the skull conductivity via somatosensory evoked responses. Our results show that, unlike single modality EEG or MEG, combined EMEG uses the complementary information of both modalities and thereby allows accurate source reconstructions also at early instants in time (epileptic spike onset, i.e., time points with low SNR, which are not yet subject to propagation and thus supposed to be closer to the origin of the epileptic activity. EMEG is furthermore able to reveal the propagation pathway at later time points in agreement with sEEG, while EEG or MEG alone reconstructed only parts of it. Subaveraging provides important and accurate information about both the center of gravity and the extent of the epileptogenic tissue that neither single nor grand-averaged spike localizations can supply.

  11. Combined EEG/MEG can outperform single modality EEG or MEG source reconstruction in presurgical epilepsy diagnosis.

    Science.gov (United States)

    Aydin, Ümit; Vorwerk, Johannes; Dümpelmann, Matthias; Küpper, Philipp; Kugel, Harald; Heers, Marcel; Wellmer, Jörg; Kellinghaus, Christoph; Haueisen, Jens; Rampp, Stefan; Stefan, Hermann; Wolters, Carsten H

    2015-01-01

    We investigated two important means for improving source reconstruction in presurgical epilepsy diagnosis. The first investigation is about the optimal choice of the number of epileptic spikes in averaging to (1) sufficiently reduce the noise bias for an accurate determination of the center of gravity of the epileptic activity and (2) still get an estimation of the extent of the irritative zone. The second study focuses on the differences in single modality EEG (80-electrodes) or MEG (275-gradiometers) and especially on the benefits of combined EEG/MEG (EMEG) source analysis. Both investigations were validated with simultaneous stereo-EEG (sEEG) (167-contacts) and low-density EEG (ldEEG) (21-electrodes). To account for the different sensitivity profiles of EEG and MEG, we constructed a six-compartment finite element head model with anisotropic white matter conductivity, and calibrated the skull conductivity via somatosensory evoked responses. Our results show that, unlike single modality EEG or MEG, combined EMEG uses the complementary information of both modalities and thereby allows accurate source reconstructions also at early instants in time (epileptic spike onset), i.e., time points with low SNR, which are not yet subject to propagation and thus supposed to be closer to the origin of the epileptic activity. EMEG is furthermore able to reveal the propagation pathway at later time points in agreement with sEEG, while EEG or MEG alone reconstructed only parts of it. Subaveraging provides important and accurate information about both the center of gravity and the extent of the epileptogenic tissue that neither single nor grand-averaged spike localizations can supply.

  12. Single-mode interband cascade laser sources for mid-infrared spectroscopic applications

    Science.gov (United States)

    Scheuermann, J.; von Edlinger, M.; Weih, R.; Becker, S.; Nähle, L.; Fischer, M.; Koeth, J.; Kamp, M.; Höfling, S.

    2016-05-01

    Compared to the near infrared, many technologically and industrially relevant gas species have more than an order of magnitude higher absorption features in the mid-infrared (MIR) wavelength range. These species include for example important hydrocarbons (methane, acetylene), nitrogen oxides and sulfur oxides. Tunable laser absorption spectroscopy (TLAS) has proven to be a versatile tool for gas sensing applications with significant advantages compared to other techniques. These advantages include real time measurement, standoff detection and ruggedness of the sensor. We present interband cascade lasers (ICLs), which have evolved into important laser sources for the MIR spectral range from 3 to 7 μm. ICLs achieve high efficiency by cascading optically active zones whilst using interband transitions, so they combine common diode laser as well as quantum cascade laser based technologies. Our application grade singlemode distributed feedback devices operate continuous wave at room temperature and are offering several features especially useful for high performance TLAS applications like: side mode suppression ratio of > 30 dB, continuous tuning ranges up to 30 nm, low threshold power densities and low overall power consumption. The devices are typically integrated in a thermoelectrically cooled TO-style package, hermetically sealed using a cap with anti-reflection coated window. This low power consumption as well as the compact size and ruggedness of the fabricated laser sources makes them perfectly suited for battery powered portable solutions for in field spectroscopy applications.

  13. Research of all-optical ultra-wideband triplet signal source based on a single semiconductor optical amplifier

    Science.gov (United States)

    Xue, Fei; Li, Pei-li; Zheng, Jia-jin; Wang, Li-li; Liang, Wei-kang

    2013-07-01

    A novel scheme for all-optical ultra-wideband triplet signal pulse generation based on the cross-gain modulation (XGM) in a single semiconductor optical amplifier (SOA) is demonstrated. In this scheme, only one optical source and one SOA are needed, so the configuration is simple. Due to only one wavelength is included in the generated triplet pulse, no time difference between output signal light and probe light is introduced during the transmission process. By using the software of Optisystem 7.0, the impacts of the input signal width, the optical power and the wavelength of the optical source on the generated triplet pulse are numerically simulated and studied. The results show that the proposed scheme has better triplet signal pulse when the input signal pulse width is larger, and it is insensitive to the wavelength change within a certain range.

  14. Solvothermal synthesis of uniform hexagonal-phase ZnS nanorods using a single-source molecular precursor

    International Nuclear Information System (INIS)

    Zhang Yongcai; Wang Guiyun; Hu Xiaoya; Chen Weiwei

    2006-01-01

    Pure and uniform hexagonal-phase ZnS nanorods with quantum confinement effect were synthesized by solvothermal decomposition of an air-stable, easily obtained single-source molecular precursor (zinc diethyldithiocarbamate, Zn-(DDTC) 2 ) in hydrazine hydrate aqueous solutions at 150-200 deg. C, and characterized by powder X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), transmission electron microscopy (TEM), high-resolution transmission electron microscopy (HRTEM), selected area electron diffraction (SAED) and UV-vis absorption spectra. The possible formation mechanism of one-dimensional ZnS nanostructure in the present system was also briefly discussed

  15. A numerical model of acoustic wave caused by a single positive corona source

    Science.gov (United States)

    Zhang, Bo; Li, Zhen; He, Jinliang

    2017-10-01

    Audible noise accompanies corona discharge, which is one of the most important electromagnetic environment issues of high voltage transmission lines. Most of the studies on the audible noise generated by corona discharge focused on statistical analysis of the experimental results and a series of empirical formulas were derived to predict the audible noise. However, few of them interpreted the generating mechanism of the audible noise. Sound wave in the air is actually the fluctuation of the air, which lead to the hypothesis that the sound wave is generated by the interaction of the charged particles and the air molecules in the discharge progress. To validate this hypothesis, experiments were carried out in this paper to study the relationship between the audible noise and the corona current, including the correlation both in time domain and in frequency domain. Based on the experimental results, the fluid equations of the particles in the air were introduced to study the interactions among the electrons, ions, and neutral molecules in the discharge, and a numerical model for the amplitude of corona acoustic emission was developed and validated.

  16. Aluminium foil as a single-use substrate for MALDI-MS fingerprinting of different melanoma cell lines.

    Science.gov (United States)

    Bondarenko, A; Zhu, Y; Qiao, L; Cortés Salazar, F; Pick, H; Girault, H H

    2016-05-23

    Herein, we present the intact cell matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) for the fingerprinting of human melanoma cancer cell lines grown on aluminium foil. To perform the MALDI-MS assay, melanoma cells were cultured on a flat and thin foil, which was directly transferred to the target plate of MALDI-MS for analysis. The influence of a wide range of cell fixation protocols (i.e. formalin-based and alcohol-based methods) and MALDI matrices on the obtained characteristic spectra was investigated. For the optimization of the MALDI-MS protocol, the MS fingerprints of the melanoma WM-239 cell line with and without an overexpressed enhanced green fluorescent protein were employed. The fingerprints obtained from WM-239 cells grown on aluminium foil were compared with the intact cell MALDI-MS of the cell pellet and presented higher sensitivity in a high m/z range. The optimized protocol was subsequently applied to characterise melanoma cell lines derived from different cancer stages and allowed identification of unique MS signals that could be used for differentiation between the studied cell lines (i.e. molecular weight equal to 10.0 kDa and 26.1 kDa).

  17. Review of single particle dynamics for third generation light sources through frequency map analysis

    Directory of Open Access Journals (Sweden)

    L. Nadolski

    2003-11-01

    Full Text Available Frequency map analysis [J. Laskar, Icarus 88, 266 (1990] is used here to analyze the transverse dynamics of four third generation synchrotron light sources: the ALS, the ESRF, the SOLEIL project, and Super-ACO. Time variations of the betatron tunes give additional information for the global dynamics of the beam. The main resonances are revealed; a one-to-one correspondence between the configuration space and the frequency space can be performed. We stress that the frequency maps, and therefore the dynamics optimization, are highly sensitive to sextupolar strengths and vary in a large amount from one machine to another. The frequency maps can thus be used to characterize the different machines.

  18. Analysis of field of view limited by a multi-line X-ray source and its improvement for grating interferometry.

    Science.gov (United States)

    Du, Yang; Huang, Jianheng; Lin, Danying; Niu, Hanben

    2012-08-01

    X-ray phase-contrast imaging based on grating interferometry is a technique with the potential to provide absorption, differential phase contrast, and dark-field signals simultaneously. The multi-line X-ray source used recently in grating interferometry has the advantage of high-energy X-rays for imaging of thick samples for most clinical and industrial investigations. However, it has a drawback of limited field of view (FOV), because of the axial extension of the X-ray emission area. In this paper, we analyze the effects of axial extension of the multi-line X-ray source on the FOV and its improvement in terms of Fresnel diffraction theory. Computer simulation results show that the FOV limitation can be overcome by use of an alternative X-ray tube with a specially designed multi-step anode. The FOV of this newly designed X-ray source can be approximately four times larger than that of the multi-line X-ray source in the same emission area. This might be beneficial for the applications of X-ray phase contrast imaging in materials science, biology, medicine, and industry.

  19. Development of X-ray photoelectron microscope with a compact X-ray source generated by line-focused laser irradiation

    International Nuclear Information System (INIS)

    Yamaguchi, N.; Takahashi, Z.; Nishimura, Y.; Watanabe, K.; Okamoto, Y.; Sakata, A.; Azuma, H.; Hara, T.

    2005-01-01

    A laboratory-sized X-ray photoelectron microscope was constructed using a compact X-ray source produced by line-focused laser irradiation. The system is a scanning type photoelectron microscope where X-ray beam is micro-focused via Schwarzschild optics. A compact laser-plasma X-ray source has been developed with a YAG laser, a line-focus lens assembly, an Al tape-target driver and a debris prevention system. The 13.1 nm X-ray was delivered along line plasma whose length was 0.6 or 11 mm with higher intensity than that from a point-focused source. The Schwarzschild optics having the designed demagnification of 224, which was coated with Mo/Si multilayers for 13.1 nm X-ray, was set on the beamline 1 m distant from the source. The electron energy analyser was a spherical capacitor analyser with the photoelectron image detection system that was suited for detection of vast photoelectrons excited by an X-ray pulse of ns-order duration. The spatial resolution less than 5 μm has been confirmed from the variation of As 3d electron intensity along the position of the GaAs sample coated with a photo-resist test pattern

  20. Investigations regarding the mass budget in the propagation of a passive admixture from a line source; Untersuchungen zur Stoffbilanz bei der Ausbreitung einer passiven Beimengung aus einer Linienquelle

    Energy Technology Data Exchange (ETDEWEB)

    Wenzel, A. [Brandenburgische Technische Univ. Cottbus (Germany). Inst. fuer Boden-, Luft- und Gewaesserschutz

    1998-01-01

    Under stationary conditions, passive admixtures are transported by advection and by vertical as well as horizontal turbulent diffusion. The importance of individual contributions for the exchange of passive admixtures emanating from a straight line source with a constant source strength under neutral stratification conditions is discussed. For this purpose, all terms of the mass budget for a control volume around a straight line source are calculated using a stochastic Lagrange model (LS), whose properties are discussed. As a test for the LS model, the vertical and horizontal mass flows in the soil layer are simulated and compared with SANA data. The mass flows calculated for the propagation of a passive admixture from a line source are evaluated regarding their share of the mass budget. (orig.) [Deutsch] Unter stationaeren Bedingungen erfolgt der Transport von passiven Beimengungen durch Advektion sowie vertikale und horizontale turbulente Diffusion. Die Bedeutung der einzelnen Beitraege fuer den Austausch von passiven Beimengungen, die von einer geraden Linienquelle mit konstanter Quellstaerke unter neutralen Schichtungsbedingungen ausgehen, wird diskutiert. Dazu werden mit einem Lagrangeschen stochastischen (LS) Modell, dessen Eigenschaften besprochen werden, alle Terme der Stoffbilanz fuer ein Kontrollvolumen um eine gerade Linienquelle berechnet. Als Test fuer das LS-Modell werden die vertikalen und die horizontalen Stofffluesse in der Bodenschicht simuliert und mit SANA-Daten verglichen. Die fuer die Ausbreitung einer passiven Beimengung von einer Linienquelle berechneten Massenfluesse, werden hinsichtlich ihres Anteils an der Stoffbilanz ausgewertet. (orig.)

  1. The Effect of Irrigation and Nitrogen on Growth Attributes and Chlorophyll Content of Garlic in Line Source Sprinkler Irrigation System

    Directory of Open Access Journals (Sweden)

    rahim motalebifard

    2017-02-01

    Full Text Available Introduction: With 12 million tons production per year, garlic is the fourth important crop in world. In addition to its medical value, it has been used in food industry. The Hamedan province with 1900 ha cultivation area and 38 percent of production is one of the most important garlic area productions in Iran. Few studies on water use and management of garlic exist in the world. Garlic is very sensitive to water deficit especially in tubers initiation and ripening periods. The current research was done because of scarce research on garlic production under water deficit condition in Iran and importance of plant nutrition and nutrients especially nitrogen on garlic production under stressful conditions. Nitrogen is necessary and important element for increasing the yield and quality of garlic. Application of nitrogen increases the growth trend of garlic such as number of leaves, leaf length and plant body. Reports have shown that garlic has high nitrogen requirement, particularly in the early stages of growth. Materials and Methods: This study was conducted for evaluating the combined effects of nitrogen and irrigation on the yield and quality of garlic (Allium sativumL.. The study was performed as a split-block based on randomized complete blocks design with factors of irrigation at four levels (0-3(normal irrigation, 3-6 (slight water deficit, 6-9 (moderate water deficit and 9-12 (sever water deficit meters distance from main line source sprinkler system, nitrogen at four levels (0, 50,100 and 150 kg nitrogen per ha using three replications and line source sprinkler irrigation system. The total water of irrigation levels was measured by boxes that were fixed in meddle of each plot. The statistical analysis of results were performed using themethod described by Hanks (1980. The chlorophyll index was measured using the chlorophyll meter 502 (Minolta, Spain. The chlorophyll a and bwas measured by the method described by Arnon (1946 and Gross (1991

  2. BT2 reveals new 'distributed source' water lines in comet 9P, not observed in 73P

    Science.gov (United States)

    Barber, R.; Miller, S.; Stallard, T.; Tennyson, J.

    The recently puplished Barber-Tennyson (BT2) synthetic H2 O water line list is the most complete and accurate line list in existence. It is finding application in a wide range of astrophysical environments. BT2 has been used to identify non-resonant fluorescent transitions in comets and determine rotational and spin temperatures of cometary comas from the intensities of these lines. UKIRT spectra of comet 9P/Tempel 1 reveal H2 O lines not previosly recorded in any other cometary spectra. BT2 has identified these lines as originating from rovibrational states that are not able to be populated by the normal pumping mechanism, and are assumed to be due a first stage of radiative de-excitation by molecules that have sublimed from icy grains produced by the Deep Impact event. These lines were not observed in our follow-up observations on 73P/Schwassmann-Wachmann 3, C fragment. References: Barber R.J., Tennyson J., Harris G., Tolchenov R., 2006, MNRAS, 368, 1087 Dello Russo N., DiSanti M.A., Magee-Sauer K. et al., 2004, Icarus, 168, 186 Dello Russo N., Bonev B.P., DiSanti M.A, et al., 2005, ApJ 621, 537 Barber R.J., Miller S., Stallard T., Tennyson J., et al., Icarus (submitted)

  3. Technology development for a single-photon source; Technologieentwicklung fuer eine Einzelphotonenquelle

    Energy Technology Data Exchange (ETDEWEB)

    Enzmann, Roland

    2011-08-02

    The growth of InAs-quantum dots on GaAs-substrate is established concerning low quantum dot densities (ca. 1 pro {mu}m{sup 2}) and high densities (> 100 pro {mu}m{sup 2}). However it is not possible to reach the telecommunication wavelength regime around 1.55 {mu}m with InAs-quantum dots on GaAs-substrate. In contrast to this, InP based materials, in general, provide the emission wavelength of 1.55 {mu}m. But the effort to fabricate InAs nanostructures on InP based material system by molecular beam epitaxy does not lead to quantum dots but in general to quantum dashes, which arise in high surface densities. To enable the growth of InAs-quantum dots based on InP several detailed growth studies on to InP-substrate lattice matched matrix material Al{sub x}Ga{sub y}In{sub 1-x-y}As were performed. Thereby the influence of growth rate, growth temperature, InAs coverage and the indium content on the growth surface have been investigated. InAs has been deposited on a thin indiumfree ''sublayer''. The corresponding growth studies showed that a 0.6 nm thick GaSb sublayer is the best choice. Using this technique quantum dots with surface densities from 1 to 150 per {mu}m{sup 2} could be realized. To make low quantum dot densities also on layers containing much aluminium possible, the Al{sub x}Ga{sub y}In{sub 1-x-y}As alloy was grown in the digital alloy growth mode, that is to say the pseudo binaries Al{sub 0,48}In{sub 0,52}As and Ga{sub 0,47}In{sub 0,53}As are grown by the second. By varying the bandgap of the matrix material, viz. by varying the aluminum content, single quantum dots emitting in the range from 1100 nm to 1560 nm could be realized. This way as well the optical O-band (1.3 {mu}m) with an aluminum content of 13% as the optical C-band (1.55 {mu}m) with an aluminum content of 4% could be realized. Another possibility to tailor the emission wavelength of quantum dots are so called stacked dots. In the process two layer of quantum dots

  4. High energy, single frequency, tunable laser source operating in burst mode for space based lidar applications

    Science.gov (United States)

    Cosentino, Alberto; Mondello, Alessia; Sapia, Adalberto; D'Ottavi, Alessandro; Brotini, Mauro; Gironi, Gianna; Suetta, Enrico

    2017-11-01

    This paper describes energetic, spatial, temporal and spectral characterization measurements of the Engineering Qualification Model (EQM) of the Laser Transmitter Assembly (TXA) used in the ALADIN instrument currently under development for the ESA ADM-AEOLUS mission (EADS Astrium as prime contractor for the satellite and the instrument). The EQM is equivalent to the Flight Model, with the exception of some engineering grade components. The Laser Transmitter Assembly, based on a diode pumped tripled Nd:YAG laser, is used to generate laser pulses at a nominal wavelength of 355 nm. This laser is operated in burst mode, with a pulse repetition cycle of 100 Hz during bursts. It is capable to operate in Single Longitudinal Mode and to be tuned over 25 GHz range. An internal "network" of sensors has been implemented inside the laser architecture to allow "in flight" monitoring of transmitter. Energy in excess of 100 mJ, with a spatial beam quality factor (M2) lower than 3, a spectral linewidth less than 50 MHz with a frequency stability better than 4 MHz on short term period have been measured on the EQM. Most of the obtained results are well within the expected values and match the Instrument requirements. They constitute an important achievement, showing the absence of major critical areas in terms of performance and the capability to obtain them in a rugged and compact structure suitable for space applications. The EQM will be submitted in the near future to an Environmental test campaign.

  5. Single-Source Multi-Battery Solar Charger: Analysis and Stability Issues

    Directory of Open Access Journals (Sweden)

    Alon Kuperman

    2015-06-01

    Full Text Available In this paper, dynamic analysis of a multi-battery dual mode charger, powered by a single solar array and suitable for lead-acid and lithium-ion cell-based batteries is presented. Each battery is interfaced to the solar array by means of a current-controlled buck power stage, operating either in constant power or constant voltage mode. Operation in former/latter charging mode implies regulating input/output voltage of the converter, which is a non-trivial situation since while feeding different batteries, all the converters share the same input terminals, connected to the solar array. It is revealed that when at least one of the batteries operates in constant power charging mode, open-loop instability occurs whenever converter input voltage is lower than maximum power point voltage of the solar array. Consequently, input voltage regulating controller must be designed to stabilize closed-loop dynamics for the worst case of instability, which is also derived. Moreover, it is shown that the dynamics of the converters operating under output voltage control are perceived as disturbances by input voltage control loop and must be properly rejected. Simple loop shaping design is proposed based on a PI controller, allowing stabilizing the system in case of worst case instability and rejecting output voltage control induced disturbances at the expense of non-constant, operating-point dependent closed-loop damping.

  6. Microalgae as a potential source of single-cell proteins. A review

    Directory of Open Access Journals (Sweden)

    Barka, A.

    2016-01-01

    Full Text Available Introduction. Les microalgues peuvent être considérées comme une des sources fiables de nutriments et d'autres substances de valeur pouvant satisfaire le besoin croissant en aliment et en énergie. Dans la présente revue, le potentiel global en microalgues, la teneur en protéines et une brève description de certaines espèces de microalgues sont présentés. Littérature. Malgré leur teneur élevée en protéines et en d'autres substances de valeur, la production industrielle des microalgues est encore à l'état embryonnaire. Les protéines des microalgues présentent de bonnes propriétés nutritionnelles, fonctionnelles et technofonctionnelles lorsqu'elles sont comparées aux protéines conventionnelles. Conclusions. La production des microalgues doit donc être encouragée par les autorités publiques et privées afin d'éviter les pénuries de protéines.

  7. Fusarium spp. is able to grow and invade healthy human nails as a single source of nutrients.

    Science.gov (United States)

    Galletti, J; Negri, M; Grassi, F L; Kioshima-Cotica, É S; Svidzinski, T I E

    2015-09-01

    Onychomycosis caused by Fusarium spp. is emerging, but some factors associated with its development remain unclear, such as whether this genus is keratinolytic. The main aim of the present study was to evaluate the ability of Fusarium to use the human nail as a single source of nutrients. We also performed an epidemiological study and antifungal susceptibility testing of Fusarium spp. that were isolated from patients with onychomycosis. The epidemiological study showed that Fusarium species accounted for 12.4 % of onychomycosis cases, and it was the most common among nondermatophyte molds. The most frequent species identified were F. oxysporum (36.5 %), F. solani (31.8 %), and F. subglutinans (8.3 %). Fluconazole was not active against Fusarium spp., and the response to terbinafine varied according to species. Fusarium was able to grow in vitro without the addition of nutrients and invade healthy nails. Thus, we found that Fusarium uses keratin as a single source of nutrients, and the model proposed herein may be useful for future studies on the pathogenesis of onychomycosis.

  8. Simultaneous dual-wavelength-band common-path swept-source optical coherence tomography with single polygon mirror scanner.

    Science.gov (United States)

    Mao, Youxin; Chang, Shoude; Murdock, Erroll; Flueraru, Costel

    2011-06-01

    We report a novel (to the best of our knowledge) simultaneous 1310/1550 two-wavelength band swept laser source and dual-band common-path swept-source optical coherence tomography (SS-OCT). Synchronized dual-wavelength tuning is performed by using two laser cavities and narrowband wavelength filters with a single dual-window polygonal scanner. Measured average output powers of 60 and 27 mW have been achieved for the 1310 and 1550 nm bands, respectively, while the two wavelengths were swept simultaneously from 1227 to 1387 nm for the 1310 nm band and from 1519 to 1581 nm for the 1550 nm band at an A-scan rate of 65 kHz. Broadband wavelength-division multiplexing is used for coupling two wavelengths into a common-path single-mode GRIN-lensed fiber probe to form dual-band common-path SS-OCT. Simultaneous OCT imaging at 1310 and 1550 nm is achieved. This technique allows for in vivo high-speed OCT imaging with potential application in functional (spectroscopic) investigations. © 2011 Optical Society of America

  9. Efficacy and safety of apatinib as second-line therapy for advanced gastric cancer: a single-center observational study.

    Science.gov (United States)

    Zhang, Yong; Gou, Miaomiao; Han, Chun; Li, Juan; Wang, Lijie; Qiao, Qian; Hu, Yi; Bai, Li; Liu, Zhefeng

    2017-12-05

    Apatinib has been proven to be effective and safe among patients in the third-line treatment of advanced gastric cancer in phase II and III trials. We aimed to evaluate its efficacy and safety in second-line practice, and to explore the factors associated with efficacy. Between April 2015 and May 2017, a total of 23 patients with advanced gastric adenocarcinoma or adenocarcinoma of gastroesophageal junction were enrolled and followed up retrospectively after failing the first line of systemic therapy. The median progression-free survival was 4.43 months (95% confidence interval: 1.63-7.22) and the median overall survival was 9.11 months (95% confidence interval: 8.22-9.99). Two patients achieved a partial response and 14 patients achieved stable disease. The disease control rate was 69.6% and the objective response rate was 8.7%. The most common adverse events over grade 3 were hypertension (8.7%) and thrombocytopenia (8.7%). No treatment-related death was documented during the drug administration. Apatinib is an effective regimen for the second-line treatment of advanced gastric and gastroesophageal cancer with manageable toxicity.This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. http://creativecommons.org/licenses/by-nc-nd/4.0/.

  10. Development of an on-line source-tagged model for sulfate, nitrate and ammonium: A modeling study for highly polluted periods in Shanghai, China.

    Science.gov (United States)

    Wu, Jian-Bin; Wang, Zifa; Wang, Qian; Li, Jie; Xu, Jianming; Chen, HuanSheng; Ge, Baozhu; Zhou, Guangqiang; Chang, Luyu

    2017-02-01

    An on-line source-tagged model coupled with an air quality model (Nested Air Quality Prediction Model System, NAQPMS) was applied to estimate source contributions of primary and secondary sulfate, nitrate and ammonium (SNA) during a representative winter period in Shanghai. This source-tagged model system could simultaneously track spatial and temporal sources of SNA, which were apportioned to their respective primary precursors in a simulation run. The results indicate that in the study period, local emissions in Shanghai accounted for over 20% of SNA contributions and that Jiangsu and Shandong were the two major non-local sources. In particular, non-local emissions had higher contributions during recorded pollution periods. This suggests that the transportation of pollutants plays a key role in air pollution in Shanghai. The temporal contributions show that the emissions from the "current day" (emission contribution from the current day during which the model was simulating) contributed 60%-70% of the sulfate and ammonium concentrations but only 10%-20% of the nitrate concentration, while the previous days' contributions increased during the recorded pollution periods. Emissions that were released within three days contributed over 85% averagely for SNA in January 2013. To evaluate the source-tagged model system, the results were compared by sensitivity analysis (emission perturbation of -30%) and backward trajectory analysis. The consistency of the comparison results indicated that the source-tagged model system can track sources of SNA with reasonable accuracy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Dielectric barrier discharges: progress on plasma sources and on the understanding of regimes and single filaments

    Science.gov (United States)

    Brandenburg, Ronny

    2017-05-01

    Dielectric barrier discharges (DBDs) are plasmas generated in configurations with an insulating (dielectric) material between the electrodes which is responsible for a self-pulsing operation. DBDs are a typical example of nonthermal atmospheric or normal pressure gas discharges. Initially used for the generation of ozone, they have opened up many other fields of application. Therefore DBDs are a relevant tool in current plasma technology as well as an object for fundamental studies. Another motivation for further research is the fact that so-called partial discharges in insulated high voltage systems are special types of DBDs. The breakdown processes, the formation of structures, and the role of surface processes are currently under investigation. This review is intended to give an update to the already existing literature on DBDs considering the research and development within the last two decades. The main principles and different modes of discharge generation are summarized. A collection of known as well as special electrode configurations and reactor designs will be presented. This shall demonstrate the different and broad possibilities, but also the similarities and common aspects of devices for different fields of applications explored within the last years. The main part is devoted to the progress on the investigation of different aspects of breakdown and plasma formation with the focus on single filaments or microdischarges. This includes a summary of the current knowledge on the electrical characterization of filamentary DBDs. In particular, the recent new insights on the elementary volume and surface memory mechanisms in these discharges will be discussed. An outlook for the forthcoming challenges on research and development will be given.

  12. Oxygenated organic functional groups and their sources in single and submicron organic particles in MILAGRO 2006 campaign

    Directory of Open Access Journals (Sweden)

    S. Liu

    2009-09-01

    Full Text Available Fourier Transform Infrared (FTIR and X-ray Fluorescence (XRF were used to measure organic functional groups and elements of submicron particles collected during MILAGRO in March 2006 on three platforms: the Mexico City urban area (SIMAT, the high altitude site at 4010 m (Altzomoni, and the NCAR C130 aircraft. Scanning Transmission X-ray Microscopy (STXM and Near-Edge X-ray Absorption Fine Structure (NEXAFS were applied to single particle organic functional group abundance analysis of particles simultaneously collected at SIMAT and C130. Correlations of elemental concentrations showed different groups of source-related elements at SIMAT, Altzomoni, and C130, suggesting different processes affecting the air masses sampled at the three platforms. Cluster analysis resulted in seven distinct clusters of FTIR spectra, with the last three clusters consisting of spectra collected almost exclusively on the C130 platform, reflecting the variety of sources contributing to C130 samples. Positive Matrix Factorization (PMF of STXM-NEXAFS spectra identified three main factors representing soot, secondary, and biomass burning type spectra. PMF of FTIR spectra resulted in two fossil fuel combustion factors and one biomass burning factor, the former representative of source regions to the northeast and southwest of SIMAT. Alkane, carboxylic acid, amine, and alcohol functional groups were mainly associated with combustion related sources, while non-acid carbonyl groups were likely from biomass burning events. The majority of OM and O/C was attributed to combustion sources, although no distinction between direct emissions and atmospherically processed OM could be identified.

  13. Characterization of two novel cell lines with distinct heterogeneity derived from a single human bile duct carcinoma.

    Directory of Open Access Journals (Sweden)

    Jinghan Wang

    Full Text Available BACKGROUND: Intratumoral heterogeneity reflects subclonal diversity and accounts for a variety of clinically defined phenotypes including the development of drug resistance and recurrence. However, intratumoral heterogeneity of bile duct carcinoma (BDC is rarely studied. METHODS: Two highly heterogeneous cell lines named EH-CA1a and EH-CA1b were established from a primary tumor tissue of a pathologically proven BDC. Distinct heterogeneity and underlying mechanisms of two cell lines in karyotype, colony formation, tumorgenicity, and sensitivity to chemoradiotherapy were intensively studied. RESULTS: Both cell lines showed typical morphology of cancer cells. EH-CA1a cells grew as free-floating aggregates, while EH-CA1b cells grew adherently as a monolayer. EH-CA1a cells had higher cloning efficiencies and were able to keep proliferating under hypoxic condition. Coincidentally, hypoxia-induced factor-1α (HIF1α and vascular endothelial growth factor (VEGF mRNA were significantly higher in EH-CA1a cells than in EH-CA1b cells. Both cell lines were tumorigenic in nude mouse, however, EH-CA1a cells showed more aggressive characteristics. Most importantly, the EH-CA1a cells showed much more resistance against radiation and chemotherapy with gemcitabine. Metastasis-related genes including matrix metalloproteinase 2 (MMP-2, MMP-9, epithelial-mesenchymal transition (EMT markers such as Vimentin, Snail, and Twist, are more highly expressed in EH-CA1a cells than in EH-CA1b cells. Moreover, the percentage of cells expressing cancer stem cell-like marker, CD133, in EH-CA1a cells is much higher than that in EH-CA1b cells. Moreover, knockdown of CD133 in both EH-CA1a and EH-CA1b cells significantly reduced their invasive potential and increased their sensitivities to radiation and gemcitabine, suggesting the differential expression of CD133 protein may partially account for the difference in malignancy between these two cancer cells. CONCLUSION: Establishment

  14. Analysis of CMOS hot carrier light sources using back-end-of-line light directing structures for improved light extraction efficiency

    Science.gov (United States)

    Bulling, Anthony F.; Venter, Petrus J.; du Plessis, Monuko

    2014-06-01

    Light emission from silicon is possible in CMOS through hot carrier electroluminescence. Low conversion and low extraction efficiency remains a challenge. By using existing back-end-of-line interconnect structures it is possible to improve the extraction efficiency. Such light directing structures were analysed with the use of a focused ion beam and scanning electron microscope. It was found that it is possible to improve light extraction efficiency and directionality of the light sources through a combination of back-end-of-line structures and field oxide manipulation resulting in an improved optical path for emitted photon radiation. However, further analysis indicates that total internal reflections, scattering and electromagnetic absorption from the via plugs and metal interconnects in the back-end-of-line stack are some of the key contributors to the inefficient light extraction efficiency.

  15. Demonstration of Cascaded In-Line Single-Pump Fiber Optical Parametric Amplifiers in Recirculating Loop Transmission

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Ozolins, Oskars; An, Yi

    2012-01-01

    The performance of cascaded single-pump fiber optical parametric amplifiers (FOPAs) is experimentally studied for the first time using recirculating loop transmission with 80-km dispersion managed spans. Error-free performance has been achieved over 320 km for 40-Gbit/s CSRZ-OOK and CSRZ...

  16. Evaluating lane-by-lane gap-out based signal control for isolated intersection under stop-line, single and multiple advance detection systems

    Directory of Open Access Journals (Sweden)

    Chandan Keerthi Kancharla

    2016-12-01

    Full Text Available In isolated intersection’s actuated signal control, inductive loop detector layout plays a crucial role in providingthe vehicle information to the signal controller. Based on vehicle actuations at the detector, the green time is extended till a pre-defined threshold gap-out occurs. The Federal Highway Administration (FHWA proposed various guidelines for detec-tor layouts on low-speed and high-speed approaches. This paper proposes single and multiple advance detection schemes for low-speed traffic movements, that utilizes vehicle actuations from advance detectors located upstream of the stop-line, which are able to detect spill-back queues. The proposed detection schemes operate with actuated signal control based on lane-by-lane gap-out criteria. The performance of the proposed schemes is compared with FHWA’s stop-line and single advance detection schemes in the VISSIM simulation tool. Results have shown that the proposed single advance detection schemes showed improved performance in reducing travel time delay and average number of stops per vehicle under low volumes while the multiple advance detection scheme performed well under high volumes.

  17. Maintenance therapy following first-line chemotherapy in metastatic colorectal cancer: toxicity and efficacy-single-institution experience.

    Science.gov (United States)

    Fedyanin, Mikahil; Tryakin, Alexey; Vybarava, Anna; Chekini, Dzhennet; Pokataev, Ilya; Sekhina, Olga; Gordeev, Sergey; Aliev, Vechaslav; Tjulandin, Sergei

    2015-01-01

    A role of maintenance chemotherapy (mCT) in patients (pts) with metastatic colorectal cancer (mCRC) is still controversial. The purpose of this retrospective study was to investigate the toxicity and efficacy of mCT in pts with mCRC. There were 97/291 (33 %) pts with mCRC completed 18-20 weeks of first-line CT from 2007 to 2013 in our center. Then, pts who had no disease progression were non-randomly allocated to mCT with capecitabine ± bevacizumab (n = 35) or surveillance (n = 62). PFS was used as a primary endpoint and was calculated from the date of completion of first-line CT. Multivariate Cox stepwise regression analysis was performed to determine independent prognostic factors. Median follow-up time was 15 (range 5-60) months. Median PFS and OS were higher in pts with mCT: 7 versus 3 months (HR 0.5, 95 %CI 0.28-0.82, p = 0.007) and 29 vs 16 months (HR 0.6, 95 %CI 0.3-1.1, 0.04-Gehan-Breslow-Wilcoxon test). Following independent negative prognostic factors was significant on multivariate analysis: CEA level >2.5 ng/ml before start of first-line CT (p = 0.02), liver metastases (p = 0.03) and number of metastatic zones >2 (p = 0.008). MCT had an independent positive impact on PFS (HR 0.5, p = 0.003). MCT prolonged PFS in pts with at least one negative prognostic factors (7 vs. 3 months, p = 0.001, HR 0.38, 95 % CI 0.22-0.68). The mCT was most beneficial in pts with negative prognostic factors: CEA level >2.5 ng/ml before start of first-line CT and/or liver metastases and/or number of metastatic zones >2.

  18. Toxicological characterization of size-segregated urban air particulate matter in macrophage cell line - effects of chemical composition and sources

    Energy Technology Data Exchange (ETDEWEB)

    Jalava, P.

    2008-07-01

    of the chemical mass closure method in the characterization of the gravimetrically measured, size-segregated particulate mass of the HVCI samples used in toxicological studies. These results and well-established chemical tracers were utilized in the identification of potentially harmful particulate sources. Inflammatory properties of the HVCI particulate samples were investigated in an immortalized mouse macrophage cell line (RAW264.7). They were assessed by measuring the production of proinflammatory cytokines (IL-6, TNFalpha) and chemokine (MIP-2) by macrophages exposed to the particulate samples. Nitric oxide production was also measured. Cell viability, apoptosis and the stage of the cell cycle of the macrophages were analyzed as indicators of cytotoxicity. Toxicity profiles of the samples collected during different air pollution situations in Helsinki varied extensively. The overall toxicity of the PM{sub 1-0.2} mass per cubic meter of air during transnational forest fire smoke episodes was estimated as being higher than the seasonal average in springtime. The particulate samples in PM{sub 10-2.5} size range were the most potent inducers of inflammation and cytotoxicity. However, the air pollution situation strongly affected the particle-induced responses in six European cities. There was more heterogeneity in the toxic responses in association with the PM{sub 2.5-0.2} than the PM{sub 10-2.5} samples. In both size ranges, the responses were mainly due to the insoluble fraction of the particulate samples with only minor effects by the water-soluble or organic solvent soluble fractions. The PM{sub 0.2} samples did not substantially increase cytokine production, but some samples exhibited cytotoxic and apoptotic activity. This suggests that the solubility and the chemical composition of the particulate material affect the toxic potency and that the material in different particulate size ranges can activate distinct biological mechanisms. There were a larger number

  19. Construction of a single/multiple wavelength RZ optical pulse source at 40 GHz by use of wavelength conversion in a high-nonlinearity DSF-NOLM

    DEFF Research Database (Denmark)

    Yu, Jianjun; Yujun, Qian; Jeppesen, Palle

    2001-01-01

    A single or multiple wavelength RZ optical pulse source at 40 GHz is successfully obtained by using wavelength conversion in a nonlinear optical loop mirror consisting of high nonlinearity-dispersion shifted fiber.......A single or multiple wavelength RZ optical pulse source at 40 GHz is successfully obtained by using wavelength conversion in a nonlinear optical loop mirror consisting of high nonlinearity-dispersion shifted fiber....

  20. Line profiles of water for the photon dominated region and embedded sources in the S140 region

    NARCIS (Netherlands)

    Poelman, D. R.; Spaans, M.

    H(2)O is a key ingredient in many interstellar environments, like photon dominated regions and star forming clouds. It plays an important role in the oxygen chemistry and can act as a coolant in dense interstellar clouds and shocks. Observations and modelling of water lines thus provide powerful

  1. Investigating Advances in the Acquisition of Secure Systems Based on Open Architecture, Open Source Software, and Software Product Lines

    Science.gov (United States)

    2012-01-27

    software system acquisition within the DoD, whether focusing on SPLs ( Bergey & Jones, 2010; Guertin & Clements, 2010), or on how to improve software system...Engineering (SEKE2011), Miami, FL. Bergey , J., & Jones, L. (2010). Exploring acquisition strategies for adopting a software product line approach. In

  2. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    International Nuclear Information System (INIS)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques; Santangelo, Teresa; Duhamel, Alain; Deschildre, Antoine

    2017-01-01

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol 32 ) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP 32 was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP 32 , CTDI vol32 and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP 32 , 0.78-1.25 mGy for the CTDI vol32 and 1.6-2.1 mGy for the SSDE. (orig.)

  3. Radiation dose levels in pediatric chest CT: experience in 499 children evaluated with dual-source single-energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Martine, Remy-Jardin; Colas, Lucie; Jean-Baptiste, Faivre; Remy, Jacques [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Santangelo, Teresa [CHU Lille (EA 2694) University of Lille, Department of Thoracic Imaging, Hospital Calmette, Lille (France); Bambino Gesu Children' s Hospital, Department of Imaging, Rome (Italy); Duhamel, Alain [University of Lille (EA 2694), Department of Biostatistics, CHU Lille, Lille (France); Deschildre, Antoine [CHU Lille - University of Lille, Department of Pediatric Pulmonology, Lille (France)

    2017-02-15

    The availability of dual-source technology has introduced the possibility of scanning children at lower kVp with a high-pitch mode, combining high-speed data acquisition and high temporal resolution. To establish the radiation dose levels of dual-source, single-energy chest CT examinations in children. We retrospectively recorded the dose-length product (DLP) of 499 consecutive examinations obtained in children <50 kg, divided into five weight groups: group 1 (<10 kg, n = 129); group 2 (10-20 kg, n = 176); group 3 (20-30 kg, n = 99), group 4 (30-40 kg, n = 58) and group 5 (40-49 kg, n = 37). All CT examinations were performed with high temporal resolution (75 ms), a high-pitch mode and a weight-adapted selection of the milliamperage. CT examinations were obtained at 80 kVp with a milliamperage ranging between 40 mAs and 90 mAs, and a pitch of 2.0 (n = 162; 32.5%) or 3.0 (n = 337; 67.5%). The mean duration of data acquisition was 522.8 ± 192.0 ms (interquartile range 390 to 610; median 490). In the study population, the mean CT dose index volume (CTDIvol{sub 32}) was 0.83 mGy (standard deviation [SD] 0.20 mGy; interquartile range 0.72 to 0.94; median 0.78); the mean DLP{sub 32} was 21.4 mGy.cm (SD 9.1 mGy.cm; interquartile range 15 to 25; median 19.0); and the mean size-specific dose estimate (SSDE) was 1.7 mGy (SD 0.4 mGy; interquartile range 1.5 to 1.9; median 1.7). The DLP{sub 32}, CTDI{sub vol32} and SSDE were found to be statistically significant in the five weight categories (P < 0.0001). This study establishes the radiation dose levels for dual-source, single-kVp chest CT from a single center. In the five weight categories, the median values varied 15-37 mGy.cm for the DLP{sub 32}, 0.78-1.25 mGy for the CTDI{sub vol32} and 1.6-2.1 mGy for the SSDE. (orig.)

  4. A Generation Control of Arbitrary AC Waveforms for the Single-phase Voltage Source PWM Inverter Utilizing an Adaptive Frequency Loss-less Resonator

    Science.gov (United States)

    Hashino, Satoshi; Wada, Keiji; Shimizu, Toshihisa

    Power supplies used on the electric power environment test process for electronic products and audio-amplifiers are required to generate arbitrary ac voltage waveforms in the wide frequency range. Traditionally, analogue amplifier technologies have been used for those application even though those have the disadvantages of low-efficiency, bulky in volume, and heavy in weight. Recently, however, research on the arbitrary waveform power generator becomes to be attractive among power electronics engineers, because the audio amplifiers utilizes the D-Mode switching technologies have been move into the market. This paper presents an arbitrary ac power generator utilizes a novel instantaneous waveform control method for a single-phase voltage source PWM inverter. A remarkable feature of this control method is that an adaptive frequency band-pass filter based on a rotation frame transformation and a command generator on the rotation frame is used. The proposed method can suppress the resonance caused by the LC filter at the output line, and hence it enables to generate a rectangular voltage waveform without overshoot. The command generator generates both an instantaneous frame angle and accurate voltage commands on the rotating frame from one an analogue signal. The effectiveness of this method is verified through 500W experimental set-up.

  5. Electrophysiological Features of Single Store-Operated Calcium Channels in HEK S4 Cell Line with Stable STIM1 Protein Knockdown.

    Science.gov (United States)

    Shalygin, A V; Vigont, V A; Glushankova, L N; Zimina, O A; Kolesnikov, D O; Skopin, A Yu; Kaznacheeva, E V

    2017-07-01

    An important role in intracellular calcium signaling is played by store-operated channels activated by STIM proteins, calcium sensors of the endoplasmic reticulum. In stable STIM1 knockdown HEK S4 cells, single channels activated by depletion of intracellular calcium stores were detected by cell-attached patch-clamp technique and their electrophysiological parameters were described. Comparison of the properties of single channels in HEK293 and HEK S4 cells revealed no significant differences in their current-voltage curves, while regulation of store-operated calcium channels in these cell lines depended on the level of STIM1 expression. We can conclude that electrophysiological peculiarities of store-regulated calcium entry observed in different cells can be explained by differences in STIM1 expression.

  6. Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners.

    Science.gov (United States)

    Saba, Luca; di Martino, Michele; Siotto, Paolo; Anzidei, Michele; Argiolas, Giovanni Maria; Porcu, Michele; Suri, Jasjit S; Wintermark, Max

    2018-03-01

    The purpose of this work was to compare the image quality and radiation dose delivered to patients during computed tomography (CT) angiography (CTA) of the supra-aortic arteries using two single-source (SS) and two dual-energy (DE) CT scanners. In this retrospective study, 120 patients who underwent CTA of supra-aortic arteries were studied using four different types of CT scanners: a sixteen and forty-detector-row SS and two DE CT scanners. Seventy milliters of contrast medium were injected at a flow rate of 4mL/s using a power injector. For each patient the dose-length product (DLP), the volume computed tomography dose index (CDTIvol), the length of the scan and the effective dose (ED) were calculated. Qualitative and quantitative [image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] image quality assessment was performed. A statistically significant lower value of the DE compared to the SS technology (P<0.0001) for the CDTI, DLP and ED was found, whereas we did not find any statistically significant difference between the four scanners for the measurements of the image noise, SNR and CNR. DS CT scanners allow performing CTAs with a reduced dose compared to SS CT scanner with comparable image quality. Copyright © 2017. Published by Elsevier Masson SAS.

  7. Obtaining better performance in the measurement-device-independent quantum key distribution with heralded single-photon sources

    Science.gov (United States)

    Zhou, Xing-Yu; Zhang, Chun-Hui; Zhang, Chun-Mei; Wang, Qin

    2017-11-01

    Measurement-device-independent quantum key distribution (MDI-QKD) has been widely investigated due to its remarkable advantages on the achievable transmission distance and practical security. However, the relative low key generation rate limits its real-life implementations. In this work, we adopt the newly proposed four-intensity decoy-state scheme [Phys. Rev. A 93, 042324 (2016), 10.1103/PhysRevA.93.042324] to study the performance of MDI-QKD with heralded single-photon sources (HSPS). Corresponding simulation results demonstrate that the four-intensity decoy-state scheme combining HSPS can drastically improve both the key generation rate and transmission distance in MDI-QKD, which may be very promising in future MDI-QKD systems.

  8. Analysis of using protons in secondary beam on BEPC as a particle source in single event effects experiment study

    International Nuclear Information System (INIS)

    He Chaohui; Li Guozheng; Liu Enke

    1999-01-01

    The energy range and yield of the protons in the secondary beam on BEPC are first analyzed, at the point of using the protons as a particle source in the single event effects (SEE) experiment of semiconductor devices. The energy ranges of the proton produced by high energy electrons bombarding on targets in three methods are calculated and the corresponding cross sections are estimated. The cross section of producing protons can be increased by using heavy nucleus target and the differential yield of protons can reach 1.66 x 10 -3 s -1 ·sr -1 ·eV -1 . The protons can be used in SEE experiment of the semiconductor devices with the high SEE cross sections

  9. Single photon sources in 4H-SiC metal-oxide-semiconductor field-effect transistors

    Science.gov (United States)

    Abe, Y.; Umeda, T.; Okamoto, M.; Kosugi, R.; Harada, S.; Haruyama, M.; Kada, W.; Hanaizumi, O.; Onoda, S.; Ohshima, T.

    2018-01-01

    We present single photon sources (SPSs) embedded in 4H-SiC metal-oxide-semiconductor field-effect transistors (MOSFETs). They are formed in the SiC/SiO2 interface regions of wet-oxidation C-face 4H-SiC MOSFETs and were not found in other C-face and Si-face MOSFETs. Their bright room-temperature photoluminescence (PL) was observed in the range from 550 to 750 nm and revealed variable multi-peak structures as well as variable peak shifts. We characterized a wide variety of their PL spectra as the inevitable variation of local atomic structures at the interface. Their polarization dependence indicates that they are formed at the SiC side of the interface. We also demonstrate that it is possible to switch on/off the SPSs by a bias voltage of the MOSFET.

  10. Growth and characterization of semiconducting nickel sulfide nanocrystals from air-stable single-source metal organic precursors

    Directory of Open Access Journals (Sweden)

    Sohail Saeed

    2015-12-01

    Full Text Available Three symmetrical and unsymmetrical nickel(II complexes [cis-(C3H72NC(SNC(OC6H3(3,5-NO22]2Ni(II, [cis-(C4H92NC(SNC(OC6H3(3,5-NO22]2Ni(II, and [cis-(Hex(Me2NC(SNC(O C6H3(3,5-NO22]2Ni(II were synthesized and characterized by FTIR spectroscopy, elemental analysis, and mass spectrometry. These metal complexes have been used as single-source precursors for the preparation of semiconducting nickel sulfide nanocrystals. Rapid injection of metal complexes into oleylamine at 230°C, followed by immediate cooling, led to the formation of irregular-shaped 20–170-nm nickel sulfide nanocrystals. The deposited nickel sulfide nanocrystals were characterized by X-ray powder diffraction and transmission electron microscopy.

  11. Single-channel properties of a stretch-sensitive chloride channel in the human mast cell line HMC-1.

    Science.gov (United States)

    Wang, Lina; Ding, Guanghong; Gu, Quanbao; Schwarz, Wolfgang

    2010-04-01

    A stretch-activated (SA) Cl(-) channel in the plasma membrane of the human mast cell line HMC-1 was identified in outside-out patch-clamp experiments. SA currents, induced by pressure applied to the pipette, exhibited voltage dependence with strong outward rectification (55.1 pS at +100 mV and an about tenfold lower conductance at -100 mV). The probability of the SA channel being open (P (o)) also showed steep outward rectification and pressure dependence. The open-time distribution was fitted with three components with time constants of tau(1o) = 755.1 ms, tau(2o) = 166.4 ms, and tau(3o) = 16.5 ms at +60 mV. The closed-time distribution also required three components with time constants of tau(1c) = 661.6 ms, tau(2c) = 253.2 ms, and tau(3c) = 5.6 ms at +60 mV. Lowering extracellular Cl(-) concentration reduced the conductance, shifted the reversal potential toward chloride reversal potential, and decreased the P (o) at positive potentials. The SA Cl(-) currents were reversibly blocked by the chloride channel blocker 4,4'-diisothiocyanatostilbene-2,2'-disulfonic acid (DIDS) but not by (Z)-1-(p-dimethylaminoethoxyphenyl)-1,2-diphenyl-1-butene (tamoxifen). Furthermore, in HMC-1 cells swelling due to osmotic stress, DIDS could inhibit the increase in intracellular [Ca(2+)] and degranulation. We conclude that in the HMC-1 cell line, the SA outward currents are mediated by Cl(-) influx. The SA Cl(-) channel might contribute to mast cell degranulation caused by mechanical stimuli or accelerate membrane fusion during the degranulation process.

  12. A single-phase multi-level D-STATCOM inverter using modular multi-level converter (MMC) topology for renewable energy sources

    Science.gov (United States)

    Sotoodeh, Pedram

    This dissertation presents the design of a novel multi-level inverter with FACTS capability for small to mid-size (10-20kW) permanent-magnet wind installations using modular multi-level converter (MMC) topology. The aim of the work is to design a new type of inverter with D-STATCOM option to provide utilities with more control on active and reactive power transfer of distribution lines. The inverter is placed between the renewable energy source, specifically a wind turbine, and the distribution grid in order to fix the power factor of the grid at a target value, regardless of wind speed, by regulating active and reactive power required by the grid. The inverter is capable of controlling active and reactive power by controlling the phase angle and modulation index, respectively. The unique contribution of the proposed work is to combine the two concepts of inverter and D-STATCOM using a novel voltage source converter (VSC) multi-level topology in a single unit without additional cost. Simulations of the proposed inverter, with 5 and 11 levels, have been conducted in MATLAB/Simulink for two systems including 20 kW/kVAR and 250 W/VAR. To validate the simulation results, a scaled version (250 kW/kVAR) of the proposed inverter with 5 and 11 levels has been built and tested in the laboratory. Experimental results show that the reduced-scale 5- and 11-level inverter is able to fix PF of the grid as well as being compatible with IEEE standards. Furthermore, total cost of the prototype models, which is one of the major objectives of this research, is comparable with market prices.

  13. 78 FR 17413 - Announcement of the Award of an Urgent Single-Source Grant to the Center for Survivors of Torture...

    Science.gov (United States)

    2013-03-21

    ...-Source Grant to the Center for Survivors of Torture in Dallas, TX AGENCY: Office of Refugee Resettlement... award of an urgent single-source grant to the Center for Survivors of Torture to provide mental health... Center for Survivors of Torture (CST) in Dallas, TX to ensure incoming refugee populations in Texas have...

  14. Analysis of a finite-difference and a Galerkin technique applied to the simulation of advection and diffusion of air pollutants from a line source

    International Nuclear Information System (INIS)

    Runca, E.; Melli, P.; Sardei, F.

    1985-01-01

    A finite-difference scheme and a Galerkin scheme are compared with respect to a very accurate solution describing time-dependent advection and diffusion of air pollutants from a line source in an atmosphere vertically stratified and limited by an inversion layer. The accurate solution was achieved by applying the finite-difference scheme on a very refined grid with a very small time step. The grid size and time step were defined according to stability and accuracy criteria discussed in the text. It is found that for the problem considered the two methods can be considered equally accurate. However, the Galerkin method gives a better approximation in the vicinity of the source. This was assumed to be partly due to the different way the source term is taken into account in the two methods. Improvement of the accuracy of the finite-difference scheme was achieved by approximating, at every step, the contribution of the source term by a Gaussian puff moving and diffusing with the velocity and diffusivity of the source location, instead of utilizing a stepwise function for the numerical approximation of the delta function representing the source term

  15. Analysis and classification of oncology activities on the way to workflow based single source documentation in clinical information systems.

    Science.gov (United States)

    Wagner, Stefan; Beckmann, Matthias W; Wullich, Bernd; Seggewies, Christof; Ries, Markus; Bürkle, Thomas; Prokosch, Hans-Ulrich

    2015-12-22

    Today, cancer documentation is still a tedious task involving many different information systems even within a single institution and it is rarely supported by appropriate documentation workflows. In a comprehensive 14 step analysis we compiled diagnostic and therapeutic pathways for 13 cancer entities using a mixed approach of document analysis, workflow analysis, expert interviews, workflow modelling and feedback loops. These pathways were stepwise classified and categorized to create a final set of grouped pathways and workflows including electronic documentation forms. A total of 73 workflows for the 13 entities based on 82 paper documentation forms additionally to computer based documentation systems were compiled in a 724 page document comprising 130 figures, 94 tables and 23 tumour classifications as well as 12 follow-up tables. Stepwise classification made it possible to derive grouped diagnostic and therapeutic pathways for the three major classes - solid entities with surgical therapy - solid entities with surgical and additional therapeutic activities and - non-solid entities. For these classes it was possible to deduct common documentation workflows to support workflow-guided single-source documentation. Clinical documentation activities within a Comprehensive Cancer Center can likely be realized in a set of three documentation workflows with conditional branching in a modern workflow supporting clinical information system.

  16. Source characterization of urban particles from meat smoking activities in Chongqing, China using single particle aerosol mass spectrometry.

    Science.gov (United States)

    Chen, Yang; Wenger, John C; Yang, Fumo; Cao, Junji; Huang, Rujin; Shi, Guangming; Zhang, Shumin; Tian, Mi; Wang, Huanbo

    2017-09-01

    A Single Particle Aerosol Mass Spectrometer (SPAMS) was deployed in the urban area of Chongqing to characterize the particles present during a severe particulate pollution event that occurred in winter 2014-2015. The measurements were made at a time when residents engaged in traditional outdoor meat smoking activities to preserve meat before the Chinese Spring Festival. The measurement period was predominantly characterized by stagnant weather conditions, highly elevated levels of PM 2.5 , and low visibility. Eleven major single particle types were identified, with over 92.5% of the particles attributed to biomass burning emissions. Most of the particle types showed appreciable signs of aging in the stagnant air conditions. To simulate the meat smoking activities, a series of controlled smoldering experiments was conducted using freshly cut pine and cypress branches, both with and without wood logs. SPAMS data obtained from these experiments revealed a number of biomass burning particle types, including an elemental and organic carbon (ECOC) type that proved to be the most suitable marker for meat smoking activities. The traditional activity of making preserved meat in southwestern China is shown here to be a major source of particulate pollution. Improved measures to reduce emissions from the smoking of meat should be introduced to improve air quality in regions where smoking meat activity prevails. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Widely tunable single-bandpass microwave photonic filter based on polarization processing of a nonsliced broadband optical source.

    Science.gov (United States)

    Wang, Hui; Zheng, Jian Yu; Li, Wei; Wang, Li Xian; Li, Ming; Xie, Liang; Zhu, Ning Hua

    2013-11-15

    We propose a new scheme of microwave photonic filter (MPF) based on the polarization processing of a broadband optical source (BOS), which features single-bandpass response and a wide span of operation bandwidth. The BOS is orthogonally polarized by a polarization division multiplexing emulator (PDME) with a tunable time delay between the two polarization states and incident at ± 45° to one principle axis of a polarization modulator (PolM). The PDME cascades a PolM, and a polarizer realizes a microwave modulation making the phase of the carrier able to be tuned while ± 1st sidebands remain unchanged, which after propagating in a dispersive medium results in a tunable single-bandpass response in the RF domain. We experimentally verify the MPF. By adjusting the time delay and the optical spectrum bandwidth, the passband center frequency is continuously tuned from DC to 20 GHz and the 3 dB passband bandwidth changes while the optical spectrum bandwidth ranges from 1 to 4 nm.

  18. A single-phase axially-magnetized permanent-magnet oscillating machine for miniature aerospace power sources

    Science.gov (United States)

    Sui, Yi; Zheng, Ping; Cheng, Luming; Wang, Weinan; Liu, Jiaqi

    2017-05-01

    A single-phase axially-magnetized permanent-magnet (PM) oscillating machine which can be integrated with a free-piston Stirling engine to generate electric power, is investigated for miniature aerospace power sources. Machine structure, operating principle and detent force characteristic are elaborately studied. With the sinusoidal speed characteristic of the mover considered, the proposed machine is designed by 2D finite-element analysis (FEA), and some main structural parameters such as air gap diameter, dimensions of PMs, pole pitches of both stator and mover, and the pole-pitch combinations, etc., are optimized to improve both the power density and force capability. Compared with the three-phase PM linear machines, the proposed single-phase machine features less PM use, simple control and low controller cost. The power density of the proposed machine is higher than that of the three-phase radially-magnetized PM linear machine, but lower than the three-phase axially-magnetized PM linear machine.

  19. Optimization of in-line phase contrast particle image velocimetry using a laboratory x-ray source

    International Nuclear Information System (INIS)

    Ng, I.; Fouras, A.; Paganin, D. M.

    2012-01-01

    Phase contrast particle image velocimetry (PIV) using a laboratory x-ray microfocus source is investigated using a numerical model. Phase contrast images of 75 μm air bubbles, embedded within water exhibiting steady-state vortical flow, are generated under the paraxial approximation using a tungsten x-ray spectrum at 30 kVp. Propagation-based x-ray phase-contrast speckle images at a range of source-object and object-detector distances are generated, and used as input into a simulated PIV measurement. The effects of source-size-induced penumbral blurring, together with the finite dynamic range of the detector, are accounted for in the simulation. The PIV measurement procedure involves using the cross-correlation between temporally sequential speckle images to estimate the transverse displacement field for the fluid. The global error in the PIV reconstruction, for the set of simulations that was performed, suggests that geometric magnification is the key parameter for designing a laboratory-based x-ray phase-contrast PIV system. For the modeled system, x-ray phase-contrast PIV data measurement can be optimized to obtain low error ( 15 μm) of the detector, high geometric magnification (>2.5) is desired, while for large source size system (FWHM > 30 μm), low magnification (<1.5) would be suggested instead. The methods developed in this paper can be applied to optimizing phase-contrast velocimetry using a variety of laboratory x-ray sources.

  20. Two-dimensional transport of dust from an infinite line source at ground level: non-zero roughness height

    International Nuclear Information System (INIS)

    Hassan, M.H.A.; Eltayeb, I.A.

    1992-07-01

    The previous study (Eltayeb and Hassan, 1992) of the two-dimensional diffusion equation of dust over a rough ground surface, which acts as a dust source of variable strength, under the influence of horizontal wind and gravitational attraction is here extended to all finite values of the roughness height Z 0 . An analytic expression is obtained for the concentration of dust for a general strength of the source. The result reduces to the previously known solutions as special cases. The expression for the concentration has been evaluated for some representative example of the source strength g(X). It is found that the concentration decreases with roughness height at any fixed point above ground level. (author). 4 refs, 2 figs

  1. Underwater tracking of a moving dipole source using an artificial lateral line: algorithm and experimental validation with ionic polymer–metal composite flow sensors

    International Nuclear Information System (INIS)

    Abdulsadda, Ahmad T; Tan, Xiaobo

    2013-01-01

    Motivated by the lateral line system of fish, arrays of flow sensors have been proposed as a new sensing modality for underwater robots. Existing studies on such artificial lateral lines (ALLs) have been mostly focused on the localization of a fixed underwater vibrating sphere (dipole source). In this paper we examine the problem of tracking a moving dipole source using an ALL system. Based on an analytical model for the moving dipole-generated flow field, we formulate a nonlinear estimation problem that aims to minimize the error between the measured and model-predicted magnitudes of flow velocities at the sensor sites, which is subsequently solved with the Gauss–Newton scheme. A sliding discrete Fourier transform (SDFT) algorithm is proposed to efficiently compute the evolving signal magnitudes based on the flow velocity measurements. Simulation indicates that it is adequate and more computationally efficient to use only the signal magnitudes corresponding to the dipole vibration frequency. Finally, experiments conducted with an artificial lateral line consisting of six ionic polymer–metal composite (IPMC) flow sensors demonstrate that the proposed scheme is able to simultaneously locate the moving dipole and estimate its vibration amplitude and traveling speed with small errors. (paper)

  2. Plant regeneration of bananas Ambon kuning and Barangan mutant lines were carried out by using female organ and shoot-tip as explants source

    International Nuclear Information System (INIS)

    Dewi, Azri K; Ishak

    1998-01-01

    Plant regeneration of bananas Ambon Kuning and Barangan mutant lines were carried out by using female organ and shoot-tip as explants source. Female organ was taken from heart of banana stem, while shoot-tip taken from sucker in banana plantation at Pasar Jumat, Jakarta. Those explants were cultured on MS medium containing 3 mg/l BAP, 0.5 mg/l IAA and supplemented by 100 tyrosin and 80 mg/l adenin hemisulphate. Observation showed that 180 and 42 buds were obtained from JBR 02 mutant lines respectively, while 84 and 79 buds for JAK 01 and JAK 02 respectively. The highest shoot formation was 1.013 shoots were obtained from BRC variety and lowest one was JBR 01 mutant line. statistical data analysis indicated that shoot formation between BRC variety and another mutant lines were significant difference using LSD test at level 0.05. Plantlet formation derived from female organ as well as shoot-tip showed that BRC variety produced number of plantlets per bottle was higher that another one. (author)

  3. Estimation and comparison of the radiation effective dose during coronary computed tomography angiography examinations on single-source 64-MDCT and dual-source 128-MDCT.

    Science.gov (United States)

    Khoramian, Daryoush; Sistani, Soroush

    2017-12-01

    To estimate and compare the radiation dose associated with coronary computed tomography angiography (CCTA) examinations on two multi-detector CT scanners (MDCT), 64-MDCT and 128-MDCT, in daily practice. Scan parameters of 90 patients undergoing retrospective electrocardiographic gating spiral CCTA exam were recorded during a period on a single-source 64-MDCT and a dual-source 128-MDCT, and average scan parameters were derived that were used for dosimetry. The computed tomography dose index (CTDI) with a pencil ionisation chamber and polymethyl methacrylate body phantom with diameter of 32 cm was measured on both scanners. The dose-length product (DLP) was calculated and the DLP to effective dose conversion factor (for chest scan at 120 kV of 0.014 mSv mGy -1 cm -1 ) was used to estimate effective dose (ED). Patients' heart rate, scan length, pitch factor, CTDIv, DLP and ED for 128-MDCT were 64 (5) (beats min -1 ), 161 (10) (mm), 0.26, 47 (12) (mGy), 769 (212) (mGy cm) and 10.3 (3.1) (mSv), respectively [mean (one standard deviation)]. Patients' heart rate, scan length, pitch factor, CTDIv, DLP and ED for 64-MDCT were 60 (7) (beats min -1 ), 172 (14) (mm), 0.2, 60 (6) (mGy), 1068 (98) (mGy cm) and 14.9 (1.4) (mSv), respectively. Our results indicated that the CTDIv, DLP and the effective dose with 128-MDCT is significantly lower than with 64-MDCT (p CT scanners was not significant (p > 0.05) and the kV was constant for both scanners (120 kV), the differences resulted from a shorter scan length on the 128-MDCT and use of a higher pitch factor (0.26 and 0.2 in the 128-MDCT and 64-MDCT, respectively). Comparison with other published studies confirms the findings and indicates methods for reducing patient dose.

  4. A framework to quantify karyotype variation associated with CHO cell line instability at a single-cell level.

    Science.gov (United States)

    Baik, Jong Youn; Lee, Kelvin H

    2017-05-01

    Chinese hamster ovary (CHO) cells, the major mammalian host cells for biomanufacturing of therapeutic proteins, have been extensively investigated to enhance productivity and product quality. However, cell line instability resulting in unexpected changes in productivity or product quality continues to be a challenge. Based on previous reports about causes and characteristics of production instability, we hypothesized that chromosomal rearrangements due to genomic instability are associated with production instability and that these events can be characterized. We developed a production instability model using secreted alkaline phosphatase (SEAP)-expressing CHO cells (CHO-SEAP) as well as a framework to quantify chromosomal rearrangements by karyotyping. In the absence of methotrexate (MTX), CHO-SEAP cells exhibited a slightly increased growth rate, a significantly decreased specific productivity, and changes in the chromosomal rearrangement ratio of seven chromosomes. In contrast, when MTX was re-introduced, the growth rate and SEAP productivity reversed to the initial values, demonstrating the reversibility of production instability in CHO-SEAP cells. Fluorescence in situ hybridization analysis identified that the SEAP genes were incorporated in the chromosomal rearrangement (insertion) part of the der(Z9) chromosome. Karyotype analysis indicated that the insertion ratio of the der(Z9) chromosome decreased in the CHO-SEAP cells grown without MTX, demonstrating a correlation between chromosomal rearrangement and production instability. Our results support a mechanism for production instability, wherein a randomly generated chromosomal rearrangement (or genotype) results in cells with a growth advantage that is also associated with non (or low)-producing traits. As a result, the non-producing cells grow faster and thereby outgrow the producing population. Biotechnol. Bioeng. 2017;114: 1045-1053. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Spectrum of Singly Charged Uranium (U II : Theoretical Interpretation of Energy Levels, Partition Function and Classified Ultraviolet Lines

    Directory of Open Access Journals (Sweden)

    Ali Meftah

    2017-06-01

    Full Text Available In an attempt to improve U II analysis, the lowest configurations of both parities have been interpreted by means of the Racah-Slater parametric method, using Cowan codes. In the odd parity, including the ground state, 253 levels of the interacting configurations 5 f 3 7 s 2 + 5 f 3 6 d 7 s + 5 f 3 6 d 2 + 5 f 4 7 p + 5 f 5 are interpreted by 24 free parameters and 64 constrained ones, with a root mean square (rms deviation of 60 cm − 1 . In the even parity, the four known configurations 5 f 4 7 s , 5 f 4 6 d , 5 f 2 6 d 2 7 s , 5 f 2 6 d 7 s 2 and the unknown 5 f 2 6 d 3 form a basis for interpreting 125 levels with a rms deviation of 84 cm − 1 . Due to perturbations, the theoretical description of the higher configurations 5 f 3 7 s 7 p + 5 f 3 6 d 7 p remains unsatisfactory. The known and predicted levels of U II are used for a determination of the partition function. The parametric study led us to a re-investigation of high resolution ultraviolet spectrum of uranium recorded at the Meudon Observatory in the late eighties, of which the analysis was unachieved. In the course of the present study, a number of 451 lines of U II has been classified in the region 2344 –2955 Å. One new level has been established as 5 f 3 6 d 7 p ( 4 I 6 K ( J = 5.5 at 39113.98 ± 0.1 cm − 1 .

  6. Transmission line matching simulation for 350 MHz RF driver for 400 KeV (deuterium) RFQ based 14 MeV neutron source

    International Nuclear Information System (INIS)

    Sharma, Sonal; Pande, Manjiri; Handu, V.K.

    2009-01-01

    A 60 KW, 350 MHz tetrode based high power RF system is being developed for 400 KeV RFQ based 14 MeV neutron generator in Bhabha Atomic Research Centre to study physics of coupled neutron sources and subcritical assembly. This RF system requires a 2.5 kW RF driver which is being designed by using tetrode TH-393. At such high frequency i.e. 350 MHz, lumped components are not practically useful due to radiation losses. Therefore, techniques such as coaxial line with stub tuning are preferred, which minimizes these losses. Simulation of two such stub tuning based matched coaxial lines at the input and output of the tube has been done by using CST studio. CST STUDIO is a special tool for the 3D EM simulation of high frequency components

  7. Quantification of an atmospheric nucleation and growth process as a single source of aerosol particles in a city

    Science.gov (United States)

    Salma, Imre; Varga, Veronika; Németh, Zoltán

    2017-12-01

    Effects of a new aerosol particle formation (NPF) and particle diameter growth process as a single source of atmospheric particle number concentrations were evaluated and quantified on the basis of experimental data sets obtained from particle number size distribution measurements in the city centre and near-city background of Budapest for 5 years. Nucleation strength factors for a nucleation day (NSFNUC) and for a general day (NSFGEN) were derived separately for seasons and full years. The former characteristic represents the concentration increment of ultrafine (UF) particles specifically on nucleation days with respect to accumulation-mode (regional background) concentrations (particles with equivalent diameters of 100-1000 nm; N100-1000) due solely to the nucleation process. The latter factor expresses the contribution of nucleation to particle numbers on general days; thus, it represents a longer time interval such as season or year. The nucleation source had the largest effect on the concentrations around noon and early afternoon, as expected. During this time interval, it became the major source of particles in the near-city background. Nucleation increased the daily mean concentrations on nucleation days by mean factors of 2.3 and 1.58 in the near-city background and city centre, respectively. Its effect was largest in winter, which was explained by the substantially lower N100-1000 levels on nucleation days than those on non-nucleation days. On an annual timescale, 37 % of the UF particles were generated by nucleation in the near-city background, while NPF produced 13 % of UF particles in the city centre. The differences among the annual mean values, and among the corresponding seasonal mean values, were likely caused by the variability in controlling factors from year to year. The values obtained represent the lower limits of the contributions. The shares determined imply that NPF is a non-negligible or substantial source of particles in near

  8. On-line biomedical databases-the best source for quick search of the scientific information in the biomedicine.

    Science.gov (United States)

    Masic, Izet; Milinovic, Katarina

    2012-06-01

    Most of medical journals now has it's electronic version, available over public networks. Although there are parallel printed and electronic versions, and one other form need not to be simultaneously published. Electronic version of a journal can be published a few weeks before the printed form and must not has identical content. Electronic form of a journals may have an extension that does not contain a printed form, such as animation, 3D display, etc., or may have available fulltext, mostly in PDF or XML format, or just the contents or a summary. Access to a full text is usually not free and can be achieved only if the institution (library or host) enters into an agreement on access. Many medical journals, however, provide free access for some articles, or after a certain time (after 6 months or a year) to complete content. The search for such journals provide the network archive as High Wire Press, Free Medical Journals.com. It is necessary to allocate PubMed and PubMed Central, the first public digital archives unlimited collect journals of available medical literature, which operates in the system of the National Library of Medicine in Bethesda (USA). There are so called on- line medical journals published only in electronic form. It could be searched over on-line databases. In this paper authors shortly described about 30 data bases and short instructions how to make access and search the published papers in indexed medical journals.

  9. Sensitive analysis of amino acids with carrier-mediated single drop microextraction in-line coupled with capillary electrophoresis.

    Science.gov (United States)

    Choi, Jeongmi; Choi, Kihwan; Kim, Jihye; Ahmed, Ahmed Yacine Badjah Hadj; Al-Othman, Zeid A; Chung, Doo Soo

    2011-10-14

    In order to analyze amino acids sensitively without derivatization, we have developed carrier-mediated single drop microextraction (SDME). Nonane-1-sulfonic acid was added to an acidic sample donor solution as a carrier to form neutral ion pair complexes with amino acids. The ion pair complexes were extracted to the organic phase, covering a drop of an aqueous basic acceptor phase hanging at the tip of a capillary, and then back-extracted to the basic acceptor phase, where both the amino acids and the carrier have negative charges and the ion pair complexes are broken. The resulting extract of enriched amino acids was injected into the capillary and analyzed by capillary electrophoresis. With 20-min SDME with agitation of the donor phase, enrichment factors of four aromatic amino acids were up to 120-fold, yielding the LOD of 70-500 nM. The linear dynamic ranges for corrected peak areas were 1-100 μM with linear correlation coefficients larger than 0.9959. With internal standardization, the intraday RSDs of migration times and corrected peak areas were 0.01-0.04% and 2.0-3.7%, respectively. The capabilities of sample cleanup including desalting and preconcentration of carrier-mediated SDME were demonstrated with the analysis of human urine after minimal pretreatment of acidification and centrifugation. Copyright © 2011. Published by Elsevier B.V.

  10. Determined Initial lead for South Of Isua (SOI) terrain suggests a single homogeneous source for it and possibly other archaean rocks

    Science.gov (United States)

    Tera, F.

    2011-12-01

    A Thorogenic-Uranogenic Lead Isotope Plane (TULIP), which entails plotting 206/208 (or its reverse) vs 207/208 (or its reverse), was applied to the Pb data on South of Isua (SOI) by Kamber et al., (1). When the data on 20 samples of these rocks and feldspars are plotted in pairs (each pair is a rock and its feldspar) on TULIP, they fall on 10 mixing lines that converge on a single spot (Fig. 1). This is the end member initial lead (EMIL). The 206/208 & 207/208 so determined are 0.3675 and 0.43525, respectively. From these values one calculates 207/206 = 1.1843 ± 0.0007, for EMIL. This pattern requires either: A) each pair has a singular kappa, K = 232Th/238U, different from others, or B) a pair's in situ decay Pb was homogenized in recent times. On 204/206 vs 207/206 diagram, the whole rocks of SOI define a 3.776 Ga isochron (2). From this and EMIL's 207/206, one obtains: 206/204 = 10.977, 207/204 = 12.974; and 208/204 = 29.756. This singularity of initial Pb contrasts with a deduced variability by the original authors (1). EMIL's radiogenic *(207/206) = 1.6220, gives a single-stage age = 5.9 Ga, indicating inapplicability of its evolution in one stage. Also, the μ calculated from 238U-206Pb for the single stage is different from that inferred from 235U-207Pb, confirming disqualification of this scenario. Reconciliation of the two decay schemes necessitates assumption of EMIL evolution in a minimum of two stages. Starting at 4.563 Ga, five scenarios were assumed: First stage ends and second starts at 4.55, 4.54, 4.53, 4.52 or 4.51 Ga. Second stages end at 3.776 Ga. The calculated μ1 for the first stage are 106, 59.5, 44.6, 36.3 and 30.9 respectively. For μ2 the change is limited, from 5.45 to 5.28. Only an average calculated K for both stages is possible. For the five outlined scenarios it ranges from 1.118 to 1.111. Earlier, Tera (3) observed that initial Pb of the oldest terrestrial reservoir requires evolution in two stages. There too μ1 >> μ2. Data on

  11. Infrared heterodyne spectroscopy of astronomical and laboratory sources at 8.5 micron. [absorption line profiles of nitrogen oxide and black body emission from Moon and Mars

    Science.gov (United States)

    Mumma, M.; Kostiuk, T.; Cohen, S.; Buhl, D.; Vonthuna, P. C.

    1974-01-01

    The first infrared heterodyne spectrometer using tuneable semiconductor (PbSe) diode lasers has been constructed and was used near 8.5 micron to measure absorption line profiles of N2O in the laboratory and black body emission from the Moon and from Mars. Spectral information was recorded over a 200 MHz bandwidth using an 8-channel filter bank. The resolution was 25 MHz and the minimum detectable (black body) power was 1 x 10 to the minus 16th power watts for 8 minutes of integration. The results demonstrate the usefulness of heterodyne spectroscopy for the study of remote and local sources in the infrared.

  12. Single-source surface energy balance algorithms to estimate evapotranspiration from satellite-based remotely sensed data

    Science.gov (United States)

    Bhattarai, Nishan

    The flow of water and energy fluxes at the Earth's surface and within the climate system is difficult to quantify. Recent advances in remote sensing technologies have provided scientists with a useful means to improve characterization of these complex processes. However, many challenges remain that limit our ability to optimize remote sensing data in determining evapotranspiration (ET) and energy fluxes. For example, periodic cloud cover limits the operational use of remotely sensed data from passive sensors in monitoring seasonal fluxes. Additionally, there are many remote sensing-based single-source surface energy balance (SEB) models, but no clear guidance on which one to use in a particular application. Two widely used models---surface energy balance algorithm for land (SEBAL) and mapping ET at high resolution with internalized calibration (METRIC)---need substantial human-intervention that limits their applicability in broad-scale studies. This dissertation addressed some of these challenges by proposing novel ways to optimize available resources within the SEB-based ET modeling framework. A simple regression-based Landsat-Moderate Resolution Imaging Spectroradiometer (MODIS) fusion model was developed to integrate Landsat spatial and MODIS temporal characteristics in calculating ET. The fusion model produced reliable estimates of seasonal ET at moderate spatial resolution while mitigating the impact that cloud cover can have on image availability. The dissertation also evaluated five commonly used remote sensing-based single-source SEB models and found the surface energy balance system (SEBS) may be the best overall model for use in humid subtropical climates. The study also determined that model accuracy varies with land cover type, for example, all models worked well for wet marsh conditions, but the SEBAL and simplified surface energy balance index (S-SEBI) models worked better than the alternatives for grass cover. A new automated approach based on

  13. Effectiveness of Five Biosolids as Nitrogen Sources to Produce Single and Cumulative Ryegrass Harvests in Two Australian Soils

    Directory of Open Access Journals (Sweden)

    Rodrigo Studart Corrêa

    2016-01-01

    Full Text Available ABSTRACT Biosolids have been produced by various stabilization processes of sewage sludge, but little attention has been given to the effects of such treatments on their effectiveness to supply nitrogen for plant growth. Here, we investigated these effects by cultivating Lolium perenne (ryegrass in two Australian soils, a sandy Spodosol and a clayey Oxisol. Biosolids stabilized by either aerobic digestion, composting, CaO-liming, 250 oC heat-drying or solar irradiation of domestic sewage sludge were applied to soils at 10 increasing rates (0.25-8.0 dry Mg ha-1, and chemically fertilized soils were used as reference. Results showed that the stabilization processes affected biosolids-N agronomic rates and effectiveness to yield plant biomass, which was a function of organic-N contents mineralized in soils. In the short term, biosolids were from 1/5 (digested biosolids in Oxisol to over twice (solar-irradiated biosolids in Spodosol as effective as chemical fertilizer to produce a first single harvest. As long-term N-sources, they significantly increased the effectiveness to produce plant biomass, being from 2.0 to 4.1 times more effective than chemical fertilizer in Spodosol and 1.5-2.4 times in Oxisol. Biosolids could substitute for N fertilizer with similar or higher effectiveness to yield plant biomass, depending on the sewage sludge stabilization process, soil type and cultivation term considered. Therefore, the sound management of sewage products as N sources for crop production should consider the interaction among these factors rather than solely their N content.

  14. Laboratory estimate of the regional shortwave refractive index and single scattering albedo of mineral dust from major sources worldwide

    Science.gov (United States)

    Di Biagio, C.; Formenti, P.; Caponi, L.; Cazaunau, M.; Pangui, E.; Journet, E.; Nowak, S.; Caquineau, S.; Andreae, M. O.; Kandler, K.; Saeed, T.; Piketh, S.; Seibert, D.; Williams, E.; Balkanski, Y.; Doussin, J. F.

    2017-12-01

    Mineral dust is one of the most abundant aerosol species in the atmosphere and strongly contributes to the global and regional direct radiative effect. Still large uncertainties persist on the magnitude and overall sign of the dust direct effect, where indeed one of the main unknowns is how much mineral dust absorbs light in the shortwave (SW) spectral range. Aerosol absorption is represented both by the imaginary part (k) of the complex refractive index or the single scattering albedo (SSA, i.e. the ratio of the scattering to extinction coefficient). In this study we present a new dataset of SW complex refractive indices and SSA for mineral dust aerosols obtained from in situ measurements in the 4.2 m3 CESAM simulation chamber at LISA (Laboratoire Interuniversitaire des Systemes Atmospheriques) in Créteil, France. Investigated dust aerosol samples were issued from major desert sources worldwide, including the African Sahara and Sahel, Eastern Asia, the Middle East, Southern Africa, Australia, and the Americas, with differing iron oxides content. Results from the present study provide a regional mapping of the SW absorption by dust and show that the imaginary part of the refractive index largely varies (by up to a factor 6, 0.003-0.02 at 370 nm and 0.001-0.003 at 950 nm) for the different source areas due to the change in the particle iron oxide content. The SSA for dust varies between 0.75-0.90 at 370 nm and 0.95-0.99 at 950 nm, with the largest absorption observed for Sahelian and Australian dust aerosols. Our range of variability for k and SSA is well bracketed by already published literature estimates, but suggests that regional‒dependent values should be used in models. The possible relationship between k and the dust iron oxides content is investigated with the aim of providing a parameterization of the regional‒dependent dust absorption to include in climate models.

  15. Development of an Ionization Scheme for Gold using the Selective Laser Ion Source at the On-Line Isotope Separator ISOLDE

    CERN Document Server

    Fedosseev, V; Marsh, B A; CERN. Geneva. AB Department

    2006-01-01

    At the ISOLDE on-line isotope separation facility, the resonance ionization laser ion source (RILIS) can be used to ionize reaction products as they effuse from the target. The RILIS process of laser step-wise resonance ionization of atoms in a hot metal cavity provides a highly element selective stage in the preparation of the radioactive ion beam. As a result, the ISOLDE mass separators can provide beams of a chosen isotope with greatly reduced isobaric contamination. The number of elements available at RILIS has been extended to 26, with the addition of a new three-step ionization scheme for gold. The optimal ionization scheme was determined during an extensive study of the atomic energy levels and auto-ionizing states of gold, carried out by means of in-source resonance ionization spectroscopy. Details of the ionization scheme and a summary of the spectroscopy study are presented.

  16. Potential of maize single-cross hybrids for extraction of inbred lines using the mean components and mixed models with microsatellite marker information.

    Science.gov (United States)

    Balestre, M; Von Pinho, R G; Souza, J C; Machado, J C

    2008-10-21

    The present study examined the importance of mean (m+a' and d) components in the performance of single-cross hybrids for the formation of new populations and determined the contribution of the mixed model (best linear unbiased predictor of random effects, BLUP) method associated with molecular markers for the choice of crosses to obtain interpopulation hybrids. Ten single-cross commercial hybrids of different companies were used for this purpose, producing all possible double-cross hybrids through a complete diallel. The hybrids were evaluated in 15 locations in the agricultural year 2005/2006, using randomized complete block design with three repetitions. In three of these locations, estimates of m+a' and d were obtained. DNA was extracted from the single-cross hybrids and 20 SSR primers were used, nine of which were linked to QTL for yield. There was no correlation between m+a' of the single-cross hybrids with general combining ability (r = -0.15) inferring that populations with lines with high means do not always produce good hybrids. Also, it was observed that the correlation between the genetic distances with specific combining ability varied from 0.31 to 0.80 in the inter-group hybrids, while in the intra-group hybrids these estimates were low and non-significant. The heritability value obtained by BLUP was high and greater than that obtained by ordinary least squares (h(2) = 0.95 and 0.86), confirming the greater selection accuracy by the BLUP method. There were no differences between the accuracy values obtained with microsatellite information and without this information, inferring that there was no advantage of progenitor information on balanced data. It can be concluded that the estimate m+a' should not be used as a deciding parameter about the potential for extracting lines from a given population. The heritability and accuracy values obtained by BLUP allow the inference that it is possible to predict success in the choice of progenitors to obtain

  17. Oil type and cross-linking influence growth of Aureobasidium melanogenum on vegetable oils as a single carbon source.

    Science.gov (United States)

    Peeters, Loes H M; Huinink, Hendrik P; Voogt, Benjamin; Adan, Olaf C G

    2018-03-12

    Aureobasidium melanogenum is the main fungus found in a spontaneously formed biofilm on a oil-treated wood. This dark colored biofilm functions as a protective coating. To better understand biofilm formation, in this study A. melanogenum was cultured on olive oil and raw linseed oil. Metabolic activity and oil conversion were measured. The results show that A. melanogenum is able to grow on linseed oil and olive oil as a single carbon source. The fungus produces the enzyme lipase to convert the oil into fatty acids and glycerol. Metabolic activity and oil conversion were equal on linseed oil and olive oil. The fungus was not able to grow on severe cross-linked linseed oil, meaning that the degree of cross-linking of the oil is important for growth of A. melanogenum. Dark coloring of the colony was seen on linseed oil, which might be a stress response on the presence of autoxidation products in linseed oil. The colony on olive oil showed delayed melanin production indicating an inhibitory effect of olive oil on melanin production. © 2018 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.

  18. Iron selenide films by aerosol assisted chemical vapor deposition from single source organometallic precursor in the presence of surfactants

    Energy Technology Data Exchange (ETDEWEB)

    Hussain, Raja Azadar [Department of Chemistry, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Badshah, Amin, E-mail: aminbadshah@yahoo.com [Department of Chemistry, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Younis, Adnan [School of Materials Science and Engineering, University of New South Wales, Sydney 2052, NSW (Australia); Khan, Malik Dilshad [Department of Chemistry, Quaid-i-Azam University, 45320 Islamabad (Pakistan); Akhtar, Javeed [Department of Physics, COMSATS Institute of Information Technology, Park Road, Chak Shahzad, Islamabad (Pakistan)

    2014-09-30

    This article presents the synthesis and characterization (multinuclear nuclear magnetic resonance, Fourier transform infrared spectroscopy, carbon–hydrogen–nitrogen–sulfur analyzer, atomic absorption spectrometry and thermogravimetric analysis) of a single source organometallic precursor namely 1-acetyl-3-(4-ferrocenylphenyl)selenourea for the fabrication of iron selenide (FeSe) films on glass substrates using aerosol assisted chemical vapor deposition (AACVD). The changes in the morphologies of the films have been monitored by the use of two different surfactants i.e. triton X-100 and tetraoctylphosphonium bromide during AACVD. The role of surfactant has been evaluated by examining the interaction of the surfactants with the precursor by using UV–vis spectroscopy and cyclic voltammetry. The fabricated FeSe films have been characterized with powder X-ray diffraction, scanning electron microscopy and energy dispersive spectroscopy. - Highlights: • Ferrocene incorporated selenourea (FIS) has been synthesized and characterized. • FeSe thin films have been fabricated from FIS. • Mechanism of film growth was studied with cyclic voltammetry and UV–vis spectroscopy.

  19. Using single-chamber microbial fuel cells as renewable power sources of electro-Fenton reactors for organic pollutant treatment

    KAUST Repository

    Zhu, Xiuping

    2013-05-01

    Electro-Fenton reactions can be very effective for organic pollutant degradation, but they typically require non-sustainable electrical power to produce hydrogen peroxide. Two-chamber microbial fuel cells (MFCs) have been proposed for pollutant treatment using Fenton-based reactions, but these types of MFCs have low power densities and require expensive membranes. Here, more efficient dual reactor systems were developed using a single-chamber MFC as a low-voltage power source to simultaneously accomplish H2O2 generation and Fe2+ release for the Fenton reaction. In tests using phenol, 75±2% of the total organic carbon (TOC) was removed in the electro-Fenton reactor in one cycle (22h), and phenol was completely degraded to simple and readily biodegradable organic acids. Compared to previously developed systems based on two-chamber MFCs, the degradation efficiency of organic pollutants was substantially improved. These results demonstrate that this system is an energy-efficient and cost-effective approach for industrial wastewater treatment of certain pollutants. © 2013 Elsevier B.V.

  20. Multiple correspondence analysis and random amplified polymorphic DNA molecular typing to assess the sources of Staphylococcus aureus contamination in alheira production lines.

    Science.gov (United States)

    Esteves, A; Patarata, L; Aymerich, T; Garriga, M; Martins, C

    2007-03-01

    Sources and tracing of Staphylococcus aureus in alheira (garlic sausage) production were evaluated by multifactorial correspondence analysis (MCA) of occurrence data and a random amplified polymorphic DNA (RAPD) on S. aureus isolates. Samples from four production lines, four different production batches, and 14 different sampling sites (including raw material, different contact surfaces, and several stages of alheira manufacturing) were analyzed at four sampling times. From the 896 microbial analyses completed, a collection of 170 S. aureus isolates was obtained. Although analysis of the occurrence data alone was not elucidative enough, MCA and RAPD-PCR were able to assess the sources of contamination and to trace the spread of this microorganism along the production lines. MCA results indicated that the presence of S. aureus in alheira was related to its presence in the intermediate manufacturing stages after heat treatment but before stuffing in the casings. It was also possible to associate a cross-contamination path related to handler procedures. RAPD-PCR typing in accordance to MCA results confirmed the cross-contamination path between the raw material and casings and the role of handlers as an important cross-contamination vehicle.