WorldWideScience

Sample records for single lead shot

  1. Histopathology of mallards dosed with lead and selected substitute shot

    Science.gov (United States)

    Locke, L.N.; Irby, H.D.; Bagley, George E.

    1967-01-01

    The histopathological response of male game farm mallards fed lead, three types of plastic-coated lead, two lead-magnesium alloys, iron, copper, zinc-coated iron, and molybdenum-coated iron shot was studied. Mallards fed lead, plastic-coated lead, or lead-magnesium alloy shot developed a similar pathological response, including the formation of acid-fast intranuclear inclusion bodies in the kidneys. Birds fed iron or molybdenum-coated iron shot developed hemosiderosis of the liver. Two of four mallards fed zinc-coated iron shot also developed hemosiderosis of the liver. No lesions were found in mallards fed copper shot.

  2. The single-shot opto-digitizer

    International Nuclear Information System (INIS)

    Nail, M.; Gibert, Ph.

    2000-01-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  3. Lead shot from hunting as a source of lead in human blood

    International Nuclear Information System (INIS)

    Johansen, Poul; Pedersen, Henning Sloth; Asmund, Gert; Riget, Frank

    2006-01-01

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 μg/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 μg/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood

  4. Lead shot from hunting as a source of lead in human blood

    Energy Technology Data Exchange (ETDEWEB)

    Johansen, Poul [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)]. E-mail: poj@dmu.dk; Pedersen, Henning Sloth [Primary Health Care Center, DK-3900 Nuuk (Greenland); Asmund, Gert [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark); Riget, Frank [National Environmental Research Institute, Frederiksborgvej 399, DK-4000 Roskilde (Denmark)

    2006-07-15

    This study investigates the relationship between the intake of birds hunted with lead shot and the lead concentration in human blood. Fifty adult men from Nuuk, Greenland took part in the study. From September 2003 to June 2004 they regularly gave blood samples and recorded how many birds they ate. We found a clear relationship between the number of bird meals and blood lead and also a clear seasonal variation. The concentration was highest in mid-winter when bird consumption is at its highest. Blood lead was low (15 {mu}g/L, mean concentration) among the participants reporting not eating birds. Among those reporting to eat birds regularly, blood lead was significantly higher, up to 128 {mu}g/L (mean concentration). Concentrations depended on the frequency of bird meals: the more the bird meals, the higher the resulting blood lead. This clear relationship points to lead shot as the dominating lead source to people in Greenland. - Birds hunted with lead shot and consumed are a source of lead in human blood.

  5. Single-shot self-interference incoherent digital holography using off-axis configuration.

    Science.gov (United States)

    Hong, Jisoo; Kim, Myung K

    2013-12-01

    We propose a single-shot incoherent holographic imaging technique that adopts self-interference incoherent digital holography (SIDH) with slight tilt of the plane mirror in the optical configuration. The limited temporal coherence length of the illumination leads the guide-star hologram of the proposed system to have a Gaussian envelope of elliptical ring shape. The observation shows that the reconstruction by cross correlation with the guide-star hologram achieves better quality than the usual propagation methods. Experimentally, we verify that the hologram and 3D reconstruction can be implemented incoherently with the proposed single-shot off-axis SIDH.

  6. Single shot high resolution digital holography.

    Science.gov (United States)

    Khare, Kedar; Ali, P T Samsheer; Joseph, Joby

    2013-02-11

    We demonstrate a novel computational method for high resolution image recovery from a single digital hologram frame. The complex object field is obtained from the recorded hologram by solving a constrained optimization problem. This approach which is unlike the physical hologram replay process is shown to provide high quality image recovery even when the dc and the cross terms in the hologram overlap in the Fourier domain. Experimental results are shown for a Fresnel zone hologram of a resolution chart, intentionally recorded with a small off-axis reference beam angle. Excellent image recovery is observed without the presence of dc or twin image terms and with minimal speckle noise.

  7. Relative toxicity of lead and selected substitute shot types to game farm mallards

    Science.gov (United States)

    Irby, H.D.; Locke, L.N.; Bagley, George E.

    1967-01-01

    The acute toxicity of lead, three types of plastic-coated lead, two lead-magnesium alloys, iron, copper, zinc-coated iron, and molybdenum-coated iron shot were tested in year-old male game farm mallards. Mallards (Anus platyrhynchos) were fed eight number 6 shot of each type and observed for a period of 60 days. Ducks used totaled 230 and most shot types were tested in three replicates of 8 ducks each. Mortality and losses of body weight were the criteria used for judging toxicity. Three types of plastic-coated lead shot were as toxic (93 percent) as the commercial lead shot (96 percent). The average mortality in mallards fed lead-magnesium alloy shot was less (58 percent) than that occurring in birds fed commercial lead shot. Mortality among mallards fed iron, copper, zinc-coated iron or molybdenum-coated iron shot was significantly less than in birds fed lead shot, and was not significantly greater than the conrtols.

  8. Enhancement of the shot noise of a quantum dot–Luttinger lead system

    International Nuclear Information System (INIS)

    Yang, Kai-Hua; Liu, Bei-Yun; Wang, Huai-Yu; He, Xian

    2013-01-01

    We investigate the joint effects of the intralead electron interaction and Coulombic dot–lead interaction on the shot noise of a quantum dot coupled to Luttinger liquid leads. A formula of the shot noise is derived by applying the nonequilibrium Green function technique. The shot noise is enhanced by the dot–lead interaction. For a weak or moderately strong interaction the differential shot noise demonstrates resonant-like behavior as a function of bias and gate voltages. In the limit of strong interaction resonant behavior disappears and the differential shot noise and Fano factor scale as a power law in bias voltage. Under some parameters, the differential shot noise may become negative around resonant peaks, and the physical reason is analyzed.

  9. Radiologically contaminated lead shot reuse at the Idaho National Engineering Laboratory (INEL)

    International Nuclear Information System (INIS)

    Heileson, W.M.; Grant, R.P.

    1995-01-01

    This project involved the utilization of radioactively contaminated lead shot located at the Radioactive Waste Management Complex (RWMC) for radiation shielding on a radioactive liquid process tank located at Argonne National Laboratory-West (ANL-W). The use of previously contaminated shot precludes the radioactive contamination of clean shot. With limited treatment and disposal options for contaminated lead shot, the reuse of lead for shielding is significant due to the inherent characteristic of becoming a mixed waste when radiologically contaminated. The INEL conducted a lead cleanup campaign in 1990. This was designed to ensure control of potential Resource Conservation and Recovery Act (RCRA) regulated waste. Contaminated lead from throughout the INEL, was containerized per the lead Waste Acceptance Criteria at the generator sites. Limited areas at the INEL are designated for mixed waste storage. As a result, some of the lead was stored at the RWMC in the air support weather shield (ASWS). This lead was contaminated with small amounts of fission product contamination. The lead was in the form of shot, brick, sheet, casks, and other various sized pieces. In 1993, ANL-W identified a need for lead shot to be used as shielding in a radioactive liquid waste storage and processing tank at the Fuel Cycle Facility (FCF). The contaminated lead used on this project had been in storage as mixed waste at the RWMC. This paper will focus on the processes and problems encountered to utilize the contaminated lead shot

  10. Lead shot ingestion in two raptor species from Doñana, Spain.

    Science.gov (United States)

    Mateo, R; Cadenas, R; Máñez, M; Guitart, R

    2001-01-01

    Diurnal raptors inhabiting wetland areas where waterfowl shooting is conducted have many opportunities to ingest lead (Pb) shot pellets when feeding on their prey. Exposure to Pb shot was studied in the Spanish imperial eagle (Aquila adalberti), an endangered species with a world population of about 150 breeding pairs, and in the red kite (Milvus milvus) from Doñana (southwest Spain). Lead exposure was evaluated by the presence of Pb shot in the pellets of both species. Results obtained by this noninvasive method demonstrated Pb shot in 11.0% of Spanish imperial eagle and 5.5% of red kite pellets. When the data of both species were pooled, there was a significant relationship between Pb shot ingestion and consumption of waterfowl during the hunting season. Pb shot found in pellets exhibited signs of erosion, and their weight distribution had peaks at 70, 170, and 240 mg, which could correspond to ammunition used for duck and goose hunting.

  11. Lead intoxication in dogs: risk assessment of feeding dogs trimmings of lead-shot game.

    Science.gov (United States)

    Høgåsen, Helga R; Ørnsrud, Robin; Knutsen, Helle K; Bernhoft, Aksel

    2016-07-25

    Expanding lead-based bullets, commonly used for hunting of big game, produce a scattering of lead particles in the carcass around the wound channel. Trimmings around this channel, which are sometimes fed to dogs, may contain lead particles. The aim of this study was to assess potential health effects of feeding dogs such trimmings. Lead ingestion most commonly causes gastrointestinal and neurological clinical signs, although renal, skeletal, haematological, cardiovascular and biochemical effects have also been reported. Experimental data indicate that a daily dose of around 1 mg lead as lead acetate/kg body weight for ten days may be considered as a Lowest Observed Effect Level in dogs. Acute toxicity documentation from the Centers for Disease Control and Prevention indicates 300 mg/kg body weight as the lowest dose of lead acetate causing death in dogs after oral ingestion. Our assessment suggests that dogs fed trimmings of lead-shot game may be affected by the amounts of lead present, and that even deadly exposure could occasionally occur. The intestinal absorption of lead from bullets was assumed to be 10-80 % of that of lead acetate, reflecting both the variability in particle size and uncertainty about the bioavailability of metallic lead in dogs. Despite data gaps, this study indicates that feeding dogs trimmings of lead-shot game may represent a risk of lead intoxication. More research is needed to assess the exact consequences, if lead-based bullets are still to be used. Meanwhile, we recommend that trimmings close to the wound channel should be made inaccessible to dogs, as well as to other domestic or wild animals.

  12. Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T-2 weighted turbo spin echo techniques

    NARCIS (Netherlands)

    Coenegrachts, K.; Delanote, J.; ter Beek, L.; Haspeslagh, M.; Bipat, S.; Stoker, J.; van Kerkhove, F.; Steyaert, L.; Rigauts, H.; Casselman, J. W.

    2007-01-01

    The purpose of this study was to compare diffusion-weighted respiratory-triggered single-shot spin echo echoplanar imaging (SS SE-EPI) sequence using four b-values (b=0, b=20, b=300, b=800 s mm(-2)) and single-shot T-2 weighted turbo spin echo (T2W SS TSE) in patients with focal liver lesions, with

  13. Single-shot 35 fs temporal resolution electron shadowgraphy

    Energy Technology Data Exchange (ETDEWEB)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)

    2013-01-14

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  14. The shot noise of a strongly correlated quantum dot coupled to the Luttinger liquid leads

    International Nuclear Information System (INIS)

    Yang, Kai-Hua; He, Xian; Wang, Huai-Yu; Liu, Kai-Di; Liu, Bei-Yun

    2014-01-01

    We study the shot noise of a strongly correlated quantum dot weakly coupled to Luttinger liquid leads in the Kondo regime by means of the extended equation of motion method. A general zero-frequency shot noise formula with good convergence is derived. The shot noise exhibits a non-monotonic dependence on voltage for weak intralead interaction. There is a peak around the Kondo temperature at low voltage when the interaction is very weak, and its height decreases rapidly with the intralead interaction increasing. When the interaction is moderately strong the peak disappears and the shot noise scales as a power law in bias voltage, indicating that the intralead electron interaction suppresses the shot noise. It is possible that the measurements of the shot noise spectrum can extract the information of the intralead interaction. - Highlights: • The shot noise of a dot coupled to Luttinger liquid leads in the Kondo regime. • A shot noise formula is derived. • Intralead interaction suppresses the shot noise. • The noise shows different voltage-dependence for different intralead interaction

  15. Using persuasive messages to encourage hunters to support regulation of lead shot

    Science.gov (United States)

    Schroeder, Susan A.; Fulton, David C.; Penning, William; Doncarlos, Kathy

    2012-01-01

    Lead shot from hunting adds the toxic metal to environments worldwide. The United States banned lead shot for hunting waterfowl in 1991 and 26 states have lead shot restrictions beyond those mandated for waterfowl hunting. The Minnesota Department of Natural Resources (MDNR) was interested in studying hunter attitudes about expanded restrictions on the use of lead shot for hunting small game to understand what communication strategies might increase public support for potential restrictions on lead shot. We mailed messages about lead shot, including 1,200 control messages and 400 of each of 9 treatment messages, and surveys to 4,800 resident small game hunters. We compared attitudes and intentions related to a possible ban among control and treatment groups. Compared to the control message, all treatment messages elicited more positive attitudes and intentions to support a ban. A basic factual message, messages with references to Ducks Unlimited, and a first-person narrative message generated the strongest support for a ban. Results also demonstrated a substantial relationship between the use of lead shot and response to persuasive messages supporting a ban.

  16. Single-shot work extraction in quantum thermodynamics revisited

    Science.gov (United States)

    Wang, Shang-Yung

    2018-01-01

    We revisit the problem of work extraction from a system in contact with a heat bath to a work storage system, and the reverse problem of state formation from a thermal system state in single-shot quantum thermodynamics. A physically intuitive and mathematically simple approach using only elementary majorization theory and matrix analysis is developed, and a graphical interpretation of the maximum extractable work, minimum work cost of formation, and corresponding single-shot free energies is presented. This approach provides a bridge between two previous methods based respectively on the concept of thermomajorization and a comparison of subspace dimensions. In addition, a conceptual inconsistency with regard to general work extraction involving transitions between multiple energy levels of the work storage system is clarified and resolved. It is shown that an additional contribution to the maximum extractable work in those general cases should be interpreted not as work extracted from the system, but as heat transferred from the heat bath. Indeed, the additional contribution is an artifact of a work storage system (essentially a suspended ‘weight’ that can be raised or lowered) that does not truly distinguish work from heat. The result calls into question the common concept that a work storage system in quantum thermodynamics is simply the quantum version of a suspended weight in classical thermodynamics.

  17. Single-shot polarimetry imaging of multicore fiber.

    Science.gov (United States)

    Sivankutty, Siddharth; Andresen, Esben Ravn; Bouwmans, Géraud; Brown, Thomas G; Alonso, Miguel A; Rigneault, Hervé

    2016-05-01

    We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element, together with an analyzer, and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single-mode fiber cores in both conventional and polarization-maintaining fiber bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual fiber core, including eigen-polarization states, phase delay, and diattenuation.

  18. Single-shot fluctuations in waveguided high-harmonic generation

    NARCIS (Netherlands)

    Goh, S.J.; Tao, Y.; van der Slot, Petrus J.M.; Bastiaens, Hubertus M.J.; Herek, Jennifer Lynn; Biedron, S.G.; Danailov, M.B.; Milton, S.V.; Boller, Klaus J.

    2015-01-01

    For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic

  19. Clarifying beliefs underlying hunter intentions to support a ban on lead shot

    Science.gov (United States)

    Schroeder, Susan A.; Fulton, David C.; Doncarlos, Kathy

    2016-01-01

    Shot from hunting adds toxic lead to environments worldwide. Existing lead shot regulations have been instituted with little understanding of hunter beliefs and attitudes. This study applied the Theory of Reasoned Action, using a multilevel, multivariate approach, to clarify how positive and negative beliefs relate to attitudes about a ban on lead shot. Structure coefficients and commonality analysis were employed to further examine relationships between beliefs and attitudes. Results suggest that while both positive and negative outcomes influence attitudes, positive outcomes were more influential for supporters and negative beliefs for opposers. Management may need to focus on the results from hunters who indicated that they would be unlikely to support a ban, as these hunters include those who may actively oppose additional efforts to regulate lead.

  20. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  1. Single-shot observation of growing streamers using an ultrafast camera

    International Nuclear Information System (INIS)

    Takahashi, E; Kato, S; Furutani, H; Sasaki, A; Kishimoto, Y; Takada, K; Matsumura, S; Sasaki, H

    2011-01-01

    A recently developed ultrafast camera that can acquire 10 8 frames per second was used to investigate positive streamer discharge. It enabled single-shot evaluation of streamer evolution without the need to consider shot-to-shot reproducibility. This camera was used to investigate streamers in argon. Growing branches, the transition when a streamer forms a return stroke, and related phenomena were clearly observed. (fast track communication)

  2. Potential hazard to human health from exposure to fragments of lead bullets and shot in the tissues of game animals.

    Directory of Open Access Journals (Sweden)

    Deborah J Pain

    Full Text Available BACKGROUND: Lead is highly toxic to animals. Humans eating game killed using lead ammunition generally avoid swallowing shot or bullets and dietary lead exposure from this source has been considered low. Recent evidence illustrates that lead bullets fragment on impact, leaving small lead particles widely distributed in game tissues. Our paper asks whether lead gunshot pellets also fragment upon impact, and whether lead derived from spent gunshot and bullets in the tissues of game animals could pose a threat to human health. METHODOLOGY/PRINCIPAL FINDINGS: Wild-shot gamebirds (6 species obtained in the UK were X-rayed to determine the number of shot and shot fragments present, and cooked using typical methods. Shot were then removed to simulate realistic practice before consumption, and lead concentrations determined. Data from the Veterinary Medicines Directorate Statutory Surveillance Programme documenting lead levels in raw tissues of wild gamebirds and deer, without shot being removed, are also presented. Gamebirds containing > or =5 shot had high tissue lead concentrations, but some with fewer or no shot also had high lead concentrations, confirming X-ray results indicating that small lead fragments remain in the flesh of birds even when the shot exits the body. A high proportion of samples from both surveys had lead concentrations exceeding the European Union Maximum Level of 100 ppb w.w. (0.1 mg kg(-1 w.w. for meat from bovine animals, sheep, pigs and poultry (no level is set for game meat, some by several orders of magnitude. High, but feasible, levels of consumption of some species could result in the current FAO/WHO Provisional Weekly Tolerable Intake of lead being exceeded. CONCLUSIONS/SIGNIFICANCE: The potential health hazard from lead ingested in the meat of game animals may be larger than previous risk assessments indicated, especially for vulnerable groups, such as children, and those consuming large amounts of game.

  3. Shot noise as a probe of spin-correlated transport through single atoms

    Science.gov (United States)

    Pradhan, S.; Fransson, J.

    2018-03-01

    We address the shot noise in the tunneling current through a local spin, pertaining to recent experiments on magnetic adatoms and single molecular magnets. We show that both uncorrelated and spin-correlated scattering processes contribute vitally to the noise spectrum. The spin-correlated scattering processes provide an additional contribution to the Landauer-Büttiker shot noise expression, accounting for correlations between the tunneling electrons and the localized spin moment. By calculating the Fano factor, we show that both super- and sub-Poissonian shot noise can be described within our approach. Our theory provides transparent insights into noise spectroscopy, consistent with recent experiments using local probing techniques on magnetic atoms.

  4. Comparative Study on the Efficacy of Two Regimens of Single-Shot ...

    African Journals Online (AJOL)

    ... mother by increasing self esteem and improving bonding with the baby. Objective: To assess and compare the satisfaction and efficacy of two regimens of single-shot spinal blocks for the relief of labor pain in women who present in active phase of labour. Design: A prospective randomised single-blind observational study

  5. Evaluation of local and systemic effects after intramuscular implantation of lead shot alternatives in rats.

    Science.gov (United States)

    Hoots, Eric A; Renberg, Walter C; Patton, Kristin M; Roush, James K

    2007-04-01

    To evaluate the local and systemic effects of IM implantation of lead shot alternatives in rats. 22 laboratory rats. Sterile IM implantation of shot metals was performed, with euthanasia and necropsy at 2, 8, 16, and 26 weeks after implantation. Skeletal muscle specimens were examined histologically and kidney specimens were tested for heavy metals. In vivo and in vitro evaluation of corrosion of metals was performed. Corrosion of susceptible metals was greatest at 2 weeks in vivo and in vitro. Inflammation associated with all pellet types was greatest 2 weeks after implantation. Nickel-plated steel incited significantly greater inflammation at 2 weeks, compared with bismuth alloy. Kidney iron concentration was significantly greater at 26 weeks, compared with other test periods. Local tissue deposition of iron was verified by use of Prussian blue staining for all iron-containing metals. Concentration of arsenic in kidneys was significantly greater at 8, 16, and 26 weeks after implantation, compared with 2 weeks. CLINICAL RELEVANCE AND IMPACT FOR HUMAN MEDICINE: Humans or dogs wounded with nickel-plated steel may require more aggressive initial monitoring than those wounded with other shot types. Monitoring of systemic arsenic concentrations may be indicated in patients wounded with shotgun pellets.

  6. Inversion recovery single-shot TurboFLASH for assessment of myocardial infarction at 3 Tesla.

    Science.gov (United States)

    Bauner, Kerstin U; Muehling, Olaf; Wintersperger, Bernd J; Winnik, Eva; Reiser, Maximilian F; Huber, Armin

    2007-06-01

    The aim of the study was to assess the diagnostic accuracy of imaging myocardial infarction with a single-shot inversion recovery turbofast low-angle shot (SS IR turboFLASH) sequence at 3.0 Tesla in comparison with an established segmented inversion recovery turboFLASH sequence at 1.5 Tesla. Fifteen patients with myocardial infarction were examined at a 1.5 Tesla magnetic resonance (MR) System (Avanto, Siemens, Medical Solutions) and at a 3.0 Tesla MR system (TIM Trio, Siemens, Medical Solutions). Imaging delayed enhancement was started 15 minutes after application of contrast material. A SS IR turboFLASH was performed at 3.0 Tesla and compared with a segmented IR turboFLASH sequence at 1.5 and at 3.0 Tesla. The IR turboFLASH sequence at 1.5 Tesla served as reference method. Infarct volumes, contrast/noise ratio (CNR) of infarcted and normal myocardium were compared with the reference method. The Single-Shot IR turboFLASH technique allows imaging 9 slices during a single breath-hold. The CNR between infarction and normal myocardium of the reference method was 6.4 at 1.5 Tesla. The mean value of CNR of the IR turboFLASH sequence was 7.3 at 3.0 Tesla for the single-shot technique and 14.1 at 3.0 Tesla for the segmented technique. No significant difference was found for the CNR values of the reference technique at 1.5 Tesla and the single-shot technique at 3.0 Tesla, however for the comparison of the segmented technique at 1.5 and at 3 Tesla (P = 0.0001). The correlation coefficients of the infarct volumes, determined with the Single-Shot IR turboFLASH and the segmented IR turboFLASH technique at 3.0 compared with the reference method, were r = 0.95 (P < 0.0001) and r = 0.95 (P < 0.0001). The loss of CNR, which is caused by replacement of the segmented technique by the single-shot technique, is completely compensated by the approximately 2-fold CNR increase at the higher field strength. The IR turboFLASH technique at 3.0 Tesla IR can be used as a single-shot technique

  7. Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

    Directory of Open Access Journals (Sweden)

    Jascha D Swisher

    Full Text Available High-resolution functional MRI is a leading application for very high field (7 Tesla human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.

  8. Detection of lead nanoparticles in game meat by single particle ICP-MS following use of lead-containing bullets

    DEFF Research Database (Denmark)

    Kollander, Barbro; Widemo, Fredrik; Ågren, Erik

    2017-01-01

    This study investigated whether game meat may contain nanoparticles of lead from ammunition. Lead nanoparticles in the range 40 to 750 nm were detected by ICP-MS in single particle mode in game shot with lead-containing bullets. The median diameter of the detected nanoparticles was around 60 nm. ...

  9. Lead isotopes and lead shot ingestion in the globally threatened marbled teal (Marmaronetta angustirostris) and white-headed duck (Oxyura leucocephala)

    Energy Technology Data Exchange (ETDEWEB)

    Svanberg, Fredrik [Department of Environmental Toxicology, Evolutionary Biology Centre, Uppsala University, Norbyvaegen 18A, SE-752 36 Uppsala (Sweden)]. E-mail: fredriksvanberg@hotmail.com; Mateo, Rafael [Instituto de Investigacion en Recursos Cinegeticos, IREC (CSIC-UCLM-JCCM), Ronda de Toledo s/n, 13071 Ciudad Real (Spain); Hillstroem, Lars [Institute of Maths, Natural and Computer Science, University of Gaevle, SE-801 76 Gaevle (Sweden); Green, Andy J. [Wetland Ecology Group, Estacion Biologica de Donana-CSIC, Pabellon del Peru, Avenida Maria Luisa s/n, E-40013 Seville (Spain); Taggart, Mark A. [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom); Raab, Andrea [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom); Meharg, Andy A. [School of Biological Sciences, University of Aberdeen, Cruickshank Bld, St Machar Dr, Aberdeen, Scotland, AB24 3UU (United Kingdom)

    2006-11-01

    Lead isotope ratios ({sup 206}Pb/{sup 207}Pb and {sup 208}Pb/{sup 207}Pb) and concentrations in the livers and bones of marbled teal and white-headed duck found dead or moribund were determined in order to establish the main lead source in these waterfowl species. Lead concentrations in bone (dry weight) and liver (wet weight) were found to be very high in many of the white-headed ducks (bone: geometric mean = 88.9 ppm, maximum = 419 ppm; liver: geometric mean = 16.8 ppm, maximum = 57.0 ppm). Some of the marbled teal had high lead levels in the bones but liver lead levels were all low (bone: geometric mean = 6.13 ppm, maximum = 112 ppm; liver: geometric mean = 0.581 ppm, maximum = 4.77 ppm). Ingested lead shot were found in 71% of the white-headed duck and 20% of the marbled teal. The {sup 206}Pb/{sup 207}Pb ratio in livers and bones of white-headed ducks and marbled teals showed no significant differences compared to the ratios obtained from lead shot. The {sup 206}Pb/{sup 207}Pb ratio in bones of marbled teal ducklings with the highest lead concentrations tended to resemble the ratios of lead shot, which supports our hypothesis that the lead was derived from the hens. We also found that the lead ratios of lead shot and lead ratios described for soils in the area overlapped, but also that the isotopic ratio {sup 206}Pb/{sup 207}Pb in lead shot used in Spain has a narrow range compared with those used in North America. The principal source of lead in many of these birds was, however, most likely lead shot, as supported by the similar isotopic ratios, high lead concentrations in tissues and evidence of ingested shot.

  10. Lead intoxication in dogs: risk assessment of feeding dogs trimmings of lead-shot game

    OpenAIRE

    H?g?sen, Helga R.; ?rnsrud, Robin; Knutsen, Helle K.; Bernhoft, Aksel

    2016-01-01

    Background Expanding lead-based bullets, commonly used for hunting of big?game, produce a scattering of lead particles in the carcass around the wound channel. Trimmings around this channel, which are sometimes fed to dogs, may contain lead particles. The aim of this study was to assess potential health effects of feeding dogs such trimmings. Results Lead ingestion most commonly causes gastrointestinal and neurological clinical signs, although renal, skeletal, haematological, cardiovascular a...

  11. Shot noise as a probe of spin-polarized transport through single atoms

    DEFF Research Database (Denmark)

    Burtzlaff, Andreas; Weismann, Alexander; Brandbyge, Mads

    2015-01-01

    Single atoms on Au(111) surfaces have been contacted with the Au tip of a low temperature scanning tunneling microscope. The shot noise of the current through these contacts has been measured up to frequencies of 120 kHz and Fano factors have been determined to characterize the transport channels...

  12. Single-shot two-dimensional full-range optical coherence tomography achieved by dispersion control

    NARCIS (Netherlands)

    Witte, S.; Baclayon, M.; Peterman, E.J.G.; Toonen, R.F.G.; Mansvelder, H.D.; Groot, M.L.

    2009-01-01

    We present a full-range Fourier-domain optical coherence tomography (OCT) system that is capable of acquiring two-dimensional images of living tissue in a single shot. By using line illumination of the sample in combination with a two-dimensional imaging spectrometer, 1040 depth scans are performed

  13. A second-order autocorrelator for single-shot measurement of ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    mental and second-harmonic frequency respectively, and 2α is the crossover angle of the beams inside the ... dispersion (GVD) effects in the crystal and spatial resolution of the imaging system. In the case ... Figure 3a shows the image of SH radiation from the KDP crystal corresponding to the single- shot operation of the ...

  14. Single-shot LIBS spectral quality for waste particles in open air

    NARCIS (Netherlands)

    Xia, H.; Bakker, M.C.M.

    2015-01-01

    This work investigates the ability of LIBS to produce quality spectra from small particles of concrete demolition waste using single-shot spectra collected in open air. The 2–8?mm materials are rounded river gravel, green glass shards, and plastic flakes. Considered are focal length, air, moisture,

  15. Single shot damage mechanism of Mo/Si multilayer optics under intense pulsed XUV-exposures

    NARCIS (Netherlands)

    Khorsand, A.R.; Sobierajski, R.; Louis, Eric; Bruijn, S.; Gleeson, A.; van de Kruijs, Robbert Wilhelmus Elisabeth; Gullikson, E.M.; Bijkerk, Frederik

    2010-01-01

    We investigated single shot damage of Mo/Si multilayer coatings exposed to the intense fs XUV radiation at the Free-electron LASer facility in Hamburg - FLASH. The interaction process was studied in situ by XUV reflectometry, time resolved optical microscopy, and “post-mortem” by

  16. MR cholangiopancreatography of pancreaticobiliary diseases: Comparison of single-shot RARE and multislice HASTE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Morrin, Martina M.; Farrell, Richard J.; McEntee, Gerry; MacMathuna, Padraic; Stack, John P.; Murrah, John G

    2000-11-01

    AIMS: We prospectively compared two breath-hold magnetic resonance cholangiopancreatography (MRCP) sequences: single-shot rapid acquisition with relaxation enhancement (RARE) and multislice half-Fourier acquisition single-shot turbo spin echo (HASTE) in imaging the pancreaticobiliary system. PATIENTS AND METHODS: The diagnostic accuracy of single-shot RARE and multislice HASTE was studied in 34 subjects who had undergone conventional cholangiopancreatography. Overall image quality, duct conspicuity, image artifact, signal intensity and contrast-to-noise ratios were assessed independently by two radiologists who were unaware of the underlying diagnosis. RESULTS: Both sequences had comparable diagnostic accuracy regarding a normal biliary system, choledocholithiasis, extra-hepatic and intra-hepatic strictures. Single-shot RARE was superior to multislice HASTE in diagnosing a normal pancreatic system, pancreatic and intrahepatic duct strictures, while providing significantly better image quality (mean {+-} SE 3.7 {+-} 0.07 vs 3.3 {+-} 0.08: P = 0.02) and significantly less image artifact (mean {+-} SE 3.6 {+-} 0.07 vs 3.2 {+-} 0.08:P = 0.01). Single-shot RARE provided significantly better duct conspicuity regarding the pancreatic duct within the body (2.7 {+-} 0.2 vs 2.1 {+-} 0.2: P = 0.003) and tail (2.4 {+-} 0.2 vs 1.6 {+-} 0.2;P = 0.0001), as well as the intrahepatic ducts (3.0 {+-} 0.1 vs 2.6 {+-} 0.1: P = 0.004) but there was no significant difference regarding the remainder of the biliary tree. CONCLUSION: Single-shot RARE provides superior image quality, duct conspicuity with the added advantage of less image artifact and shorter acquisition time. However, volume averaging can cause common bile duct stones to be missed. Therefore, multislice HASTE sequences should still be acquired if choledocholithiasis is suspected. Larger studies are required to assess the diagnostic efficacy of single-shot RARE sequences in pancreatic duct and intra-hepatic duct disease

  17. Real-time single-shot electron bunch length measurements

    CERN Document Server

    Wilke, I; Gillespie, W A; Berden, G; Knippels, G M H; Meer, A F G

    2002-01-01

    Linear accelerators employed as drivers for X-ray free electron lasers (FELs) require relativistic electron bunch with sub-picosecond bunch length. Precise bunch length measurements are important for the tuning and operation of the FELs. Previously, we have demonstrated that electro-optic detection is a powerful technique for sub-picosecond electron bunch length measurements. In those experiments, the measured bunch length was the average of all electron bunches within a macropulse. Here, for the first time, we present the measurement of the length of individual electron bunches using a development of our previous technique. In this experiment, the longitudinal electron bunch shape is encoded electro-optically on to the frequency spectrum of a chirped laser pulse. Subsequently, the laser pulse is dispersed by a grating and the spectrum is imaged with a CCD camera. Single bunch measurements are achieved by using a nanosecond gated camera, and synchronizing the gate with both the electron bunch and the laser pu...

  18. Speckle noise reduction in single-shot holographic two-wavelength contouring

    Science.gov (United States)

    Agour, Mostafa; Klattenhoff, Reiner; Falldorf, Claas; Bergmann, Ralf B.

    2017-05-01

    We present an experimental configuration that enables form measurement from a single-shot camera exposure. It combines two-wavelength contouring with spatial multiplexing synthetic-aperture digital holography. The synthetic-aperture in this work is formed by simultaneously illuminating the test object from two different angles. The two illumination directions and the two-wavelength contouring result in four holograms which are spatially multiplexed on a single camera target avoiding unwanted cross-interference between them by means of coherence gating. In contrast to standard holographic contouring methods, the proposed technique reduces speckle decorrelation noise and enables single shot form measurement. To demonstrate this technique, the shape of a micro cold drawing part is determined.

  19. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    International Nuclear Information System (INIS)

    Delsim-Hashemi, Hossein

    2008-09-01

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e + e - colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 μJ) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  20. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Delsim-Hashemi, Hossein

    2008-09-15

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e{sup +}e{sup -} colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 {mu}J) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  1. Radiation damage to amorphous carbon thin films irradiated by multiple 46.9 nm laser shots below the single-shot damage threshold

    Czech Academy of Sciences Publication Activity Database

    Juha, Libor; Hájková, Věra; Chalupský, Jaromír; Vorlíček, Vladimír; Ritucci, A.; Reale, A.; Zuppella, P.; Störmer, M.

    2009-01-01

    Roč. 105, č. 9 (2009), 093117/1-093117/3 ISSN 0021-8979 R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAA400100701 Institutional research plan: CEZ:AV0Z10100523 Keywords : single-shot damage threshold * multiple-shot exposure damage * amorphous carbon * radiation erosion * capillary-discharge XUV laser Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.072, year: 2009

  2. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-02-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  3. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-04-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  4. Single-Shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator

    Science.gov (United States)

    2016-01-11

    Single-shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator Philip Kranz1, Andreas Bengtsson1, Michaël Simoen1, Simon...Josephson Parametric Oscillator Philip Krantz1, Andreas Bengtsson1, Michaël Simoen1, Simon Gustavsson2, Vitaly Shumeiko1, W. D. Oliver2,3, C. M...2016) We propose and demonstrate a new read-out technique for a superconducting qubit by dispersively coupling it to a Josephson parametric

  5. Reliability Assessment of a Single-Shot System by Use of Screen Test Results

    Science.gov (United States)

    2018-02-01

    unlimited. NUWC Keyport #17-002. Reliability Assessment of a Single-Shot System by Use of Screen Test Results Abstract: Field reliability prediction...approach described here assumes that the defect density during testing takes the form of an exponential decay, although other mathematical functions can...be substituted for the exponential. In order to apply the decay rate function to a discrete pass/fail test scheme, the approach provides for

  6. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  7. Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time

    International Nuclear Information System (INIS)

    Wolansky, L.J.; Chong, S.; Liu, W.C.; Kang, E.; Simpson, S.W.; Karimi, S.; Akbari, H.

    1999-01-01

    Our aim was to determine the relative merits of short and long echo times (TE) with single-shot echo-planar imaging for imaging cerebral lesions such as multiple sclerosis. We examined seven patients with clinically definite multiple sclerosis were imaged at 1.5 T. Patients were scanned with spin-echo, single-shot echo-planar imaging, using TEs of 45, 75, 105, and 135 ms. Region of interest (ROI) measurements were performed on 36 lesions at or above the level of the corona radiata. The mean image contrast (IC) was highest (231.1) for a TE of 45 ms, followed by 75 ms (218.9), 105 ms (217.9), and 135 ms (191.6). When mean contrast-to-noise ratios (C/N) were compared, the value was again highest (29.7) for TE 45 ms, followed by 75 ms (28.9), 105 ms (28.5), and 135 ms (26.3). In a lesion-by-lesion comparison, TE 45 ms had the highest IC and C/N in the largest number of cases (50 % and 47.2 %, respectively). IC and C/N for TE 45 ms were superior to those of 75 ms in 64 % and 58 %, respectively. These results support the use of relatively short TEs for single-shot echo-planar imaging in the setting of cerebral lesions such as multiple sclerosis. (orig.) (orig.)

  8. Single-shot femtosecond-pulsed phase-shifting digital holography.

    Science.gov (United States)

    Kakue, Takashi; Itoh, Seiya; Xia, Peng; Tahara, Tatsuki; Awatsuji, Yasuhiro; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2012-08-27

    Parallel phase-shifting digital holography is capable of three-dimensional measurement of a dynamically moving object with a single-shot recording. In this letter, we demonstrated a parallel phase-shifting digital holography using a single femtosecond light pulse whose central wavelength and temporal duration were 800 nm and 96 fs, respectively. As an object, we set spark discharge in atmospheric pressure air induced by applying a high voltage to between two electrodes. The instantaneous change in phase caused by the spark discharge was clearly reconstructed. The reconstructed phase image shows the change of refractive index of air was -3.7 × 10(-4).

  9. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    Science.gov (United States)

    2016-04-28

    Single- shot , volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...37081 Göttingen, Germany 4School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA 5trmeyer@purdue.edu 6james.gord...us.af.mil Abstract: Single- shot , tomographic imaging of the three-dimensional concentration field is demonstrated in a turbulent gaseous free jet in co-flow

  10. Observation of Quantum Jumps of a Single Quantum Dot Spin Using Submicrosecond Single-Shot Optical Readout

    Science.gov (United States)

    Delteil, Aymeric; Gao, Wei-bo; Fallahi, Parisa; Miguel-Sanchez, Javier; Imamoǧlu, Atac

    2014-03-01

    Single-shot readout of individual qubits is typically the slowest process among the elementary single- and two-qubit operations required for quantum information processing. Here, we use resonance fluorescence from a single-electron charged quantum dot to read out the spin-qubit state in 800 nanoseconds with a fidelity exceeding 80%. Observation of the spin evolution on longer time scales reveals quantum jumps of the spin state: we use the experimentally determined waiting-time distribution to characterize the quantum jumps.

  11. Effects of lead shot ingestion on delta-aminolevulinic acid dehydratase activity, hemoglobin concentration, and serum chemistry in bald eagles

    Science.gov (United States)

    Hoffman, D.J.; Pattee, O.H.; Wiemeyer, Stanley N.; Mulhern, B.

    1981-01-01

    Lead shot ingestion by bald eagles (Haliaeetus leucocephalus) is considered to be widespread and has been implicated in the death of eagles in nature. It was recently demonstrated under experimental conditions that ingestion of as few as 10 lead shot resulted in death within 12 to 20 days. In the present study hematological responses to lead toxicity including red blood cell ALAD activity, hemoglobin concentration and 23 different blood serum chemistries were examined in five captive bald eagles that were unsuitable for rehabilitation and release. Eagles were dosed by force-feeding with 10 lead shot; they were redosed if regurgitation occurred. Red blood cell ALAD activity was inhibited by nearly 80% within 24 hours when mean blood lead concentration had increased to 0.8 parts per million (ppm). By the end of 1 week there was a significant decrease (20-25%) in hematocrit and hemoglobin, and the mean blood lead concentration was over 3 ppm. Within as little as 1-2 weeks after dosing, significant elevations in serum creatinine and serum alanine aminotransferase occurred, as well as a significant decrease in the ratio of serum aspartic aminotransferase to serum alanine aminotransferase. The mean blood lead concentration was over 5 ppm by the end of 2 weeks. These changes in serum chemistry may be indicative of kidney and liver alterations.

  12. Anti-botulism single-shot vaccine using chitosan for protein encapsulation by simple coacervation.

    Science.gov (United States)

    Sari, Roger S; de Almeida, Anna Christina; Cangussu, Alex S R; Jorge, Edson V; Mozzer, Otto D; Santos, Hércules Otacílio; Quintilio, Wagner; Brandi, Igor Viana; Andrade, Viviane Aguiar; Miguel, Angelo Samir M; Sobrinho Santos, Eliane M

    2016-12-01

    The aim of the present study was to compare the potency and safety of vaccines against Clostridium botulinum (C. botulinum) type C and D formulated with chitosan as controlled release matrix and vaccines formulated in conventional manner using aluminum hydroxide. Parameters were established for the development of chitosan microspheres, using simple coacervation to standardize the use of this polymer in protein encapsulation for vaccine formulation. To formulate a single shot vaccine inactivated antigens of C. botulinum type C and D were used with original toxin titles equal to 5.2 and 6.2 log LD50/ml, respectively. For each antigen a chitosan based solution of 50 mL was prepared. Control vaccines were formulated by mixing toxoid type C and D with aluminum hydroxide [25% Al(OH) 3 , pH 6.3]. The toxoid sterility, innocuity and potency of vaccines were evaluated as stipulated by MAPA-BRASIL according to ministerial directive no. 23. Encapsulation efficiency of BSA in chitosan was 32.5-40.37%, while that the encapsulation efficiency to toxoid type C was 41,03% (1.94 mg/mL) and of the toxoid type D was 32.30% (1.82 mg/mL). The single shot vaccine formulated using chitosan for protein encapsulation through simple coacervation showed potency and safety similar to conventional vaccine currently used in Brazilian livestock (10 and 2 IU/mL against C. botulinum type C and D, respectively). The present work suggests that our single shot vaccine would be a good option as a cattle vaccine against these C. botulinum type C and D. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    Science.gov (United States)

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  14. Single-shot secure quantum network coding on butterfly network with free public communication

    Science.gov (United States)

    Owari, Masaki; Kato, Go; Hayashi, Masahito

    2018-01-01

    Quantum network coding on the butterfly network has been studied as a typical example of quantum multiple cast network. We propose a secure quantum network code for the butterfly network with free public classical communication in the multiple unicast setting under restricted eavesdropper’s power. This protocol certainly transmits quantum states when there is no attack. We also show the secrecy with shared randomness as additional resource when the eavesdropper wiretaps one of the channels in the butterfly network and also derives the information sending through public classical communication. Our protocol does not require verification process, which ensures single-shot security.

  15. Deconvolution single shot multibox detector for supermarket commodity detection and classification

    Science.gov (United States)

    Li, Dejian; Li, Jian; Nie, Binling; Sun, Shouqian

    2017-07-01

    This paper proposes an image detection model to detect and classify supermarkets shelves' commodity. Based on the principle of the features directly affects the accuracy of the final classification, feature maps are performed to combine high level features with bottom level features. Then set some fixed anchors on those feature maps, finally the label and the position of commodity is generated by doing a box regression and classification. In this work, we proposed a model named Deconvolutiuon Single Shot MultiBox Detector, we evaluated the model using 300 images photographed from real supermarket shelves. Followed the same protocol in other recent methods, the results showed that our model outperformed other baseline methods.

  16. Single-Shot Quantum Nondemolition Detection of Individual Itinerant Microwave Photons

    Science.gov (United States)

    Besse, Jean-Claude; Gasparinetti, Simone; Collodo, Michele C.; Walter, Theo; Kurpiers, Philipp; Pechal, Marek; Eichler, Christopher; Wallraff, Andreas

    2018-04-01

    Single-photon detection is an essential component in many experiments in quantum optics, but it remains challenging in the microwave domain. We realize a quantum nondemolition detector for propagating microwave photons and characterize its performance using a single-photon source. To this aim, we implement a cavity-assisted conditional phase gate between the incoming photon and a superconducting artificial atom. By reading out the state of this atom in a single shot, we reach an external (internal) photon-detection fidelity of 50% (71%), limited by transmission efficiency between the source and the detector (75%) and the coherence properties of the qubit. By characterizing the coherence and average number of photons in the field reflected off the detector, we demonstrate its quantum nondemolition nature. We envisage applications in generating heralded remote entanglement between qubits and for realizing logic gates between propagating microwave photons.

  17. Frequency-Domain Tomography for Single-shot, Ultrafast Imaging of Evolving Laser-Plasma Accelerators

    Science.gov (United States)

    Li, Zhengyan; Zgadzaj, Rafal; Wang, Xiaoming; Downer, Michael

    2011-10-01

    Intense laser pulses propagating through plasma create plasma wakefields that often evolve significantly, e.g. by expanding and contracting. However, such dynamics are known in detail only through intensive simulations. Laboratory visualization of evolving plasma wakes in the ``bubble'' regime is important for optimizing and scaling laser-plasma accelerators. Recently snap-shots of quasi-static wakes were recorded using frequency-domain holography (FDH). To visualize the wake's evolution, we have generalized FDH to frequency-domain tomography (FDT), which uses multiple probes propagating at different angles with respect to the pump pulse. Each probe records a phase streak, imprinting a partial record of the evolution of pump-created structures. We then topographically reconstruct the full evolution from all phase streaks. To prove the concept, a prototype experiment visualizing nonlinear index evolution in glass is demonstrated. Four probes propagating at 0, 0.6, 2, 14 degrees to the index ``bubble'' are angularly and temporally multiplexed to a single spectrometer to achieve cost-effective FDT. From these four phase streaks, an FDT algorithm analogous to conventional CT yields a single-shot movie of the pump's self-focusing dynamics.

  18. Single-shot beam profile diagnostics for x-ray FEL's using gas fluorescence

    Science.gov (United States)

    Feng, Yiping; Zhu, Diling; Weninger, Clemens; Alonso-Mori, Roberto; Chollet, Matthieu; Damiani, Daniel S.; Glownia, James M.; Hastings, Jerome B.; Nelson, Silke; Song, Sanghoon; Robert, Aymeric

    2017-06-01

    We report experimental demonstration of capturing single-shot X-ray Free-electron Laser (FEL) beam profiles using gas fluorescence. The measurement was carried out at the Linac Coherent Light Source using 7 keV hard X-rays propagating through ambient air. The nitrogen fluorescence emitted upon the passage of the X-ray FEL beam were imaged using a highly sensitive optical setup, and there was sufficient optical yield that single-shot measurements were feasible. By taking two orthogonal and simultaneous images, the beam trajectory could be determined in a nearly non-invasive manner, and is best suited for photon energies in the soft X-ray regime, where such a diagnostic capability has been largely unavailable previously. The integrated intensity of the images could also serve as a non-invasive intensity monitor, complementary to current implementations of gas- and solidbased monitors. High repetition-rate Free-electron Lasers can greatly benefit from such a new diagnostic tool for eliminating potential thermal damages.

  19. Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC, is a single-shot variant of Differential Phase Contrast (DPC, which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps for various in vitro cell samples and c. elegans in a micro-fluidic channel.

  20. Single shot near edge x-ray absorption fine structure spectroscopy in the laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Mantouvalou, I., E-mail: ioanna.mantouvalou@tu-berlin.de; Witte, K.; Martyanov, W.; Jonas, A.; Grötzsch, D.; Kanngießer, B. [Institute for Optics and Atomic Physics, Technical University of Berlin, D-10623 Berlin (Germany); Streeck, C. [Physikalisch-Technische Bundesanstalt (PTB), D-10587 Berlin (Germany); Löchel, H.; Rudolph, I.; Erko, A. [Helmholtz-Zentrum Berlin, D-14109 Berlin (Germany); Stiel, H. [Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, D-12489 Berlin (Germany)

    2016-05-16

    With the help of adapted off-axis reflection zone plates, near edge X-ray absorption fine structure spectra at the C and N K-absorption edge have been recorded using a single 1.2 ns long soft X-ray pulse. The transmission experiments were performed with a laser-produced plasma source in the laboratory rendering time resolved measurements feasible independent on large scale facilities. A resolving power of E/ΔE ∼ 950 at the respective edges could be demonstrated. A comparison of single shot spectra with those collected with longer measuring time proves that all features of the used reference samples (silicon nitrate and polyimide) can be resolved in 1.2 ns. Hence, investigations of radiation sensitive biological specimen become possible due to the high efficiency of the optical elements enabling low dose experiments.

  1. Tabletop single-shot extreme ultraviolet Fourier transform holography of an extended object.

    Science.gov (United States)

    Malm, Erik B; Monserud, Nils C; Brown, Christopher G; Wachulak, Przemyslaw W; Xu, Huiwen; Balakrishnan, Ganesh; Chao, Weilun; Anderson, Erik; Marconi, Mario C

    2013-04-22

    We demonstrate single and multi-shot Fourier transform holography with the use of a tabletop extreme ultraviolet laser. The reference wave was produced by a Fresnel zone plate with a central opening that allowed the incident beam to illuminate the sample directly. The high reference wave intensity allows for larger objects to be imaged compared to mask-based lensless Fourier transform holography techniques. We obtain a spatial resolution of 169 nm from a single laser pulse and a resolution of 128 nm from an accumulation of 20 laser pulses for an object ~11x11μm(2) in size. This experiment utilized a tabletop extreme ultraviolet laser that produces a highly coherent ~1.2 ns laser pulse at 46.9 nm wavelength.

  2. Truly work-like work extraction via a single-shot analysis.

    Science.gov (United States)

    Aberg, Johan

    2013-01-01

    The work content of non-equilibrium systems in relation to a heat bath is often analysed in terms of expectation values of an underlying random work variable. However, when optimizing the expectation value of the extracted work, the resulting extraction process is subject to intrinsic fluctuations, uniquely determined by the Hamiltonian and the initial distribution of the system. These fluctuations can be of the same order as the expected work content per se, in which case the extracted energy is unpredictable, thus intuitively more heat-like than work-like. This raises the question of the 'truly' work-like energy that can be extracted. Here we consider an alternative that corresponds to an essentially fluctuation-free extraction. We show that this quantity can be expressed in terms of a one-shot relative entropy measure introduced in information theory. This suggests that the relations between information theory and statistical mechanics, as illustrated by concepts like Maxwell's demon, Szilard engines and Landauer's principle, extends to the single-shot regime.

  3. Analysis and enhancement of 3D shape accuracy in a single-shot LIDAR sensor

    Science.gov (United States)

    Han, Munhyun; Choi, Gudong; Song, Minhyup; Seo, Hongseok; Mheen, Bongki

    2017-02-01

    The accuracy of timing jitter is of prime importance in the prevalent utilization of Light Detection and Ranging (LiDAR) technology for the real-time high-resolution three-dimensional (3D) image sensor, especially for relatively small object detection in various applications, such as in the fully automated car navigation and military surveillance. To assess the accuracy of timing, that is, the accuracy of the distance or three-dimensional shape, the standard deviation method can be used in the Time-of-Flight (ToF) LiDAR technology. While most timing jitter analyses are mainly based on a fiber-network or open space at a relatively short range distance, more accurate analyses are required to extract more information about the timing jitter at in a 3D image sensor long-range free space conditions for extended LiDAR-related applications. In this paper, utilizing a Single-Shot LiDAR System (SSLs) model with a 400 MHz wideband InGaAs Avalanche Photodiode and a 1550 nm 2 nsec full width at half maximum MOPA fiber laser, we analyzed the precise timing jitter for the implemented SSLs to characterize the measurement results. Additionally, we report the enhanced results for the resolution and precision in the given SSLs using the spline interpolation method from the measured results, and multiple-shot averaging (MSA). Finally, by adapting the proposed method to an implemented high resolution 3D LiDAR prototype, called the STUD LiDAR prototype, which can be understood as one kind of SSLs because it has a single source and a single detector as in a SSLs, we observed and analyzed the 3D resolution enhancement.

  4. Single-shot readout of multiple nuclear spin qubits in diamond under ambient conditions

    Science.gov (United States)

    Jacques, Vincent

    2013-03-01

    Nuclear spins are attractive candidates for solid-state quantum information storage and processing owing to their extremely long coherence time. However, since this appealing property results from a high level of isolation from the environment, it remains a challenging task to polarize, manipulate and readout with high fidelity individual nuclear spins. A promising approach to overcome this limitation consists in utilizing an ancillary single electronic spin to detect and control remote nuclear spins coupled by hyperfine interaction. In this talk, I will show how the electronic spin of a single Nitrogen-Vacancy (NV) defect in diamond can be used as a robust platform to observe the real-time evolution of surrounding single nuclear spins under ambient conditions. Using a diamond sample with a natural abundance of 13C isotopes, we first demonstrate high fidelity initialization and single-shot readout of an individual 13C nuclear spin. By including the intrinsic 14N nuclear spin of the NV defect in the quantum register, we then report the simultaneous observation of quantum jumps linked to both nuclear spin species, providing an efficient initialization of the two qubits. These results open up new avenues for diamond-based quantum information processing (QIP) including active feedback in quantum error correction protocols and tests of quantum correlations with solid-state single spins at room temperature.

  5. Optimization And Single-Shot Characterization Of Ultrashort Thz Pulses From A Laser Wakefield Accelerator

    International Nuclear Information System (INIS)

    Plateau, G.R.; Matlis, N.H.; van Tilborg, J.; Geddes, C.G.R.; Toth, Cs.; Schroeder, C.B.; Leemans, W.P.

    2009-01-01

    We present spatiotemporal characterization of μJ-class ultrashort THz pulses generated from a laser wakefield accelerator (LWFA). Accelerated electrons, resulting from the interaction of a high-intensity laser pulse with a plasma, emit high-intensity THz pulses as coherent transition radiation. Such high peak-power THz pulses, suitable for high-field (MV/cm) pump-probe experiments, also provide a non-invasive bunch-length diagnostic and thus feedback for the accelerator. The characterization of the THz pulses includes energy measurement using a Golay cell, 2D sign-resolved electro-optic measurement and single-shot spatiotemporal electric-field distribution retrieval using a new technique, coined temporal electric-field cross-Correlation (TEX). All three techniques corroborate THz pulses of ∼ 5 μJ, with peak fields of 100's of kV/cm and ∼ 0.4 ps rms duration.

  6. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  7. Single-shot parallel full range complex Fourier-domain optical coherence tomography

    International Nuclear Information System (INIS)

    Huang Bingjie; Bu Peng; Nan Nan; Wang Xiangzhao

    2011-01-01

    We present a method of parallel full range complex Fourier-domain optical coherence tomography (FDOCT) that is capable of acquiring an artifacts-free two-dimensional (2-D) cross-sectional image, i.e. a full range B-scan tomogram, by a single shot of 2-D CCD camera. This method is based on a spatial carrier technique, in which the spatial carrier-frequency is instantaneously introduced into the 2-D spectral interferogram registered in parallel FDOCT by using a grating-generated reference beam. The spatial-carrier-contained 2-D spectral interferogram is processed through Fourier transformation to obtain a complex 2-D spectral interferogram. From the 2-D complex spectral interferomgram, a full range B-scan tomogram is reconstructed. The principle of our method is confirmed by imaging an onion sample.

  8. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  9. Single-shot in-line digital holography without twin image

    Science.gov (United States)

    Nomura, Takanori

    2018-01-01

    In-line digital holography is conventional but still attractive because of its simple optical setup. In general, sequential phase-shifting technique is mandatory to remove twin-image which makes the reconstructed image quality low. However, sequential phase-shifting technique requires multiple recording. Multiple recording means that it is not suitable for a dynamic phenomenon. In this paper, two kinds of a single-shot in-line digital holography without twin-image using a diffused illumination are presented. One is a generalized phase-shifting digital holography and the other is a computational removal of twin-image. The ideas and their experimental results are given to confirm the feasibility.

  10. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  11. Single-shot read-out of a superconducting qubit using a Josephson parametric oscillator

    Science.gov (United States)

    Krantz, Philip; Bengtsson, Andreas; Simoen, Michaël; Gustavsson, Simon; Shumeiko, Vitaly; Oliver, W. D.; Wilson, C. M.; Delsing, Per; Bylander, Jonas

    2016-01-01

    We propose and demonstrate a read-out technique for a superconducting qubit by dispersively coupling it with a Josephson parametric oscillator. We employ a tunable quarter wavelength superconducting resonator and modulate its resonant frequency at twice its value with an amplitude surpassing the threshold for parametric instability. We map the qubit states onto two distinct states of classical parametric oscillation: one oscillating state, with 185±15 photons in the resonator, and one with zero oscillation amplitude. This high contrast obviates a following quantum-limited amplifier. We demonstrate proof-of-principle, single-shot read-out performance, and present an error budget indicating that this method can surpass the fidelity threshold required for quantum computing. PMID:27156732

  12. Compressive sensing sectional imaging for single-shot in-line self-interference incoherent holography

    Science.gov (United States)

    Weng, Jiawen; Clark, David C.; Kim, Myung K.

    2016-05-01

    A numerical reconstruction method based on compressive sensing (CS) for self-interference incoherent digital holography (SIDH) is proposed to achieve sectional imaging by single-shot in-line self-interference incoherent hologram. The sensing operator is built up based on the physical mechanism of SIDH according to CS theory, and a recovery algorithm is employed for image restoration. Numerical simulation and experimental studies employing LEDs as discrete point-sources and resolution targets as extended sources are performed to demonstrate the feasibility and validity of the method. The intensity distribution and the axial resolution along the propagation direction of SIDH by angular spectrum method (ASM) and by CS are discussed. The analysis result shows that compared to ASM the reconstruction by CS can improve the axial resolution of SIDH, and achieve sectional imaging. The proposed method may be useful to 3D analysis of dynamic systems.

  13. 3 ns single-shot read-out in a quantum dot-based memory structure

    International Nuclear Information System (INIS)

    Nowozin, T.; Bimberg, D.; Beckel, A.; Lorke, A.; Geller, M.

    2014-01-01

    Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure

  14. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  15. Strong suppression of shot noise in a feedback-controlled single-electron transistor

    Science.gov (United States)

    Wagner, Timo; Strasberg, Philipp; Bayer, Johannes C.; Rugeramigabo, Eddy P.; Brandes, Tobias; Haug, Rolf J.

    2017-03-01

    Feedback control of quantum mechanical systems is rapidly attracting attention not only due to fundamental questions about quantum measurements, but also because of its novel applications in many fields in physics. Quantum control has been studied intensively in quantum optics but progress has recently been made in the control of solid-state qubits as well. In quantum transport only a few active and passive feedback experiments have been realized on the level of single electrons, although theoretical proposals exist. Here we demonstrate the suppression of shot noise in a single-electron transistor using an exclusively electronic closed-loop feedback to monitor and adjust the counting statistics. With increasing feedback response we observe a stronger suppression and faster freezing of charge current fluctuations. Our technique is analogous to the generation of squeezed light with in-loop photodetection as used in quantum optics. Sub-Poisson single-electron sources will pave the way for high-precision measurements in quantum transport similar to optical or optomechanical equivalents.

  16. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  17. Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer

    Energy Technology Data Exchange (ETDEWEB)

    Masahiro, Kato; Norio, Saito; Yuichiro, Morishita; Takahiro, Tanaka [National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba (Japan); Masahiro, Kato; Norio, Saito; Kai, Tiedtke; Pavle N, Juranic; Sorokin, A.A.; Richter, M.; Takahiro, Tanaka; Mitsuru, Nagasono; Makina, Yabashi; Kensuke, Tono; Tadashi, Togashi; Tetsuya, Ishikawa [RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo (Japan); Kai, Tiedtke; Pavle N, Juranic; Sorokin, A.A.; Jastrow, U. [Deutsches Elektronen-Synchrotron, DESY, Hamburg (Germany); Sorokin, A.A. [Ioffe Physico-Technical Institute, Polytekhnicheskaya 26, St Petersburg (Russian Federation); Richter, M.; Kroth, U.; Schoppe, H. [Physikalisch-Technische Bundesanstalt, PTB, Berlin (Germany); Tadashi, Togashi; Hiroaki, Kimura; Haruhiko, Ohashi [Japan Synchrotron Radiation Research Institute, Sayo, Hyogo (Japan)

    2010-10-15

    The absolute single-shot pulse energy of the SPring 8 extreme ultraviolet (EUV) free electron laser (FEL) was measured using a cryogenic radiometer with a relative standard uncertainty of 3%. The temperature change of the cavity in the cryogenic radiometer caused by an incident FEL pulse was determined using a lock-in amplifier and an ac Wheatstone bridge. The measured pulse energies were compared with a gas-monitor detector developed by Physikalisch-Technische Bundesanstalt/Deutsches Elektronen-Synchrotron/Ioffe Physico-Technical Institute (Ioffe) at a wavelength of 51.3 nm at the SPring-8 EUV-FEL in a shot-to-shot mode. The pulse energies measured using the two detectors agree within 2.0%. (authors)

  18. Single shot imaging through turbid medium and around corner using coherent light

    Science.gov (United States)

    Li, Guowei; Li, Dayan; Situ, Guohai

    2018-01-01

    Optical imaging through turbid media and around corner is a difficult challenge. Even a very thin layer of a turbid media, which randomly scatters the probe light, can appear opaque and hide any objects behind it. Despite many recent advances, no current method can image the object behind turbid media with single record using coherent laser illumination. Here we report a method that allows non-invasive single-shot optical imaging through turbid media and around corner via speckle correlation. Instead of being as an obstacle in forming diffractionlimited images, speckle actually can be a carrier that encodes sufficient information to imaging through visually opaque layers. Optical imaging through turbid media and around corner is experimentally demonstrated using traditional imaging system with the aid of iterative phase retrieval algorithm. Our method require neither scan of illumination nor two-arm interferometry or long-time exposure in acquisition, which has new implications in optical sensing through common obscurants such as fog, smoke and haze.

  19. A practical one-shot multispectral imaging system using a single image sensor.

    Science.gov (United States)

    Monno, Yusuke; Kikuchi, Sunao; Tanaka, Masayuki; Okutomi, Masatoshi

    2015-10-01

    Single-sensor imaging using the Bayer color filter array (CFA) and demosaicking is well established for current compact and low-cost color digital cameras. An extension from the CFA to a multispectral filter array (MSFA) enables us to acquire a multispectral image in one shot without increased size or cost. However, multispectral demosaicking for the MSFA has been a challenging problem because of very sparse sampling of each spectral band in the MSFA. In this paper, we propose a high-performance multispectral demosaicking algorithm, and at the same time, a novel MSFA pattern that is suitable for our proposed algorithm. Our key idea is the use of the guided filter to interpolate each spectral band. To generate an effective guide image, in our proposed MSFA pattern, we maintain the sampling density of the G -band as high as the Bayer CFA, and we array each spectral band so that an adaptive kernel can be estimated directly from raw MSFA data. Given these two advantages, we effectively generate the guide image from the most densely sampled G -band using the adaptive kernel. In the experiments, we demonstrate that our proposed algorithm with our proposed MSFA pattern outperforms existing algorithms and provides better color fidelity compared with a conventional color imaging system with the Bayer CFA. We also show some real applications using a multispectral camera prototype we built.

  20. Efficient Background Segmentation and Seed Point Generation for a Single-Shot Stereo System

    Science.gov (United States)

    Chen, Xiaobo; Xi, Juntong

    2017-01-01

    Single-shot stereo 3D shape measurement is becoming more popular due to its advantages of noise robustness and short acquisition period. One of the key problems is stereo matching, which is related to the efficiency of background segmentation and seed point generation, etc. In this paper, a more efficient and automated matching algorithm based on digital image correlation (DIC) is proposed. The standard deviation of image gradients and an adaptive threshold are employed to segment the background. Scale-invariant feature transform (SIFT)-based feature matching and two-dimensional triangulation are combined to estimate accurate initial parameters for seed point generation. The efficiency of background segmentation and seed point generation, as well as the measuring precision, are evaluated by experimental simulation and real tests. Experimental results show that the average segmentation time for an image with a resolution of 1280 × 960 pixels is 240 milliseconds. The efficiency of seed point generation is verified to be high with different convergence criteria. PMID:29194415

  1. Single shot, double differential spectral measurements of inverse Compton scattering in the nonlinear regime

    Directory of Open Access Journals (Sweden)

    Y. Sakai

    2017-06-01

    Full Text Available Inverse Compton scattering (ICS is a unique mechanism for producing fast pulses—picosecond and below—of bright photons, ranging from x to γ rays. These nominally narrow spectral bandwidth electromagnetic radiation pulses are efficiently produced in the interaction between intense, well-focused electron and laser beams. The spectral characteristics of such sources are affected by many experimental parameters, with intense laser effects often dominant. A laser field capable of inducing relativistic oscillatory motion may give rise to harmonic generation and, importantly for the present work, nonlinear redshifting, both of which dilute the spectral brightness of the radiation. As the applications enabled by this source often depend sensitively on its spectra, it is critical to resolve the details of the wavelength and angular distribution obtained from ICS collisions. With this motivation, we present an experimental study that greatly improves on previous spectral measurement methods based on x-ray K-edge filters, by implementing a multilayer bent-crystal x-ray spectrometer. In tandem with a collimating slit, this method reveals a projection of the double differential angular-wavelength spectrum of the ICS radiation in a single shot. The measurements enabled by this diagnostic illustrate the combined off-axis and nonlinear-field-induced redshifting in the ICS emission process. The spectra obtained illustrate in detail the strength of the normalized laser vector potential, and provide a nondestructive measure of the temporal and spatial electron-laser beam overlap.

  2. Can Ingestion of Lead Shot and Poisons Change Population Trends of Three European Birds: Grey Partridge, Common Buzzard, and Red Kite?

    Directory of Open Access Journals (Sweden)

    Carolyn B Meyer

    Full Text Available Little is known about the magnitude of the effects of lead shot ingestion alone or combined with poisons (e.g., in bait or seeds/granules containing pesticides on population size, growth, and extinction of non-waterbird avian species that ingest these substances. We used population models to create example scenarios demonstrating how changes in these parameters might affect three susceptible species: grey partridge (Perdix perdix, common buzzard (Buteo buteo, and red kite (Milvus milvus. We added or subtracted estimates of mortality due to lead shot ingestion (4-16% of mortality, depending on species and poisons (4-46% of mortality reported in the UK or France to observed mortality of studied populations after models were calibrated to observed population trends. Observed trends were decreasing for partridge (in continental Europe, stable for buzzard (in Germany, and increasing for red kite (in Wales. Although lead shot ingestion and poison at modeled levels did not change the trend direction for the three species, they reduced population size and slowed population growth. Lead shot ingestion at modeled rates reduced population size of partridges by 10%, and when combined with bait and pesticide poisons, by 18%. For buzzards, decrease in mean population size by lead shot and poisons combined was much smaller (≤ 1%. The red kite population has been recovering; however, modeled lead shot ingestion reduced its annual growth rate from 6.5% to 4%, slowing recovery. If mortality from poisoned baits could be removed, the kite population could potentially increase at a rapid annual rate of 12%. The effects are somewhat higher if ingestion of these substances additionally causes sublethal reproductive impairment. These results have uncertainty but suggest that declining or recovering populations are most sensitive to lead shot or poison ingestion, and removal of poisoned baits can have a positive impact on recovering raptor populations that frequently

  3. Can Ingestion of Lead Shot and Poisons Change Population Trends of Three European Birds: Grey Partridge, Common Buzzard, and Red Kite?

    Science.gov (United States)

    Meyer, Carolyn B; Meyer, Joseph S; Francisco, Alex B; Holder, Jennifer; Verdonck, Frederik

    2016-01-01

    Little is known about the magnitude of the effects of lead shot ingestion alone or combined with poisons (e.g., in bait or seeds/granules containing pesticides) on population size, growth, and extinction of non-waterbird avian species that ingest these substances. We used population models to create example scenarios demonstrating how changes in these parameters might affect three susceptible species: grey partridge (Perdix perdix), common buzzard (Buteo buteo), and red kite (Milvus milvus). We added or subtracted estimates of mortality due to lead shot ingestion (4-16% of mortality, depending on species) and poisons (4-46% of mortality) reported in the UK or France to observed mortality of studied populations after models were calibrated to observed population trends. Observed trends were decreasing for partridge (in continental Europe), stable for buzzard (in Germany), and increasing for red kite (in Wales). Although lead shot ingestion and poison at modeled levels did not change the trend direction for the three species, they reduced population size and slowed population growth. Lead shot ingestion at modeled rates reduced population size of partridges by 10%, and when combined with bait and pesticide poisons, by 18%. For buzzards, decrease in mean population size by lead shot and poisons combined was much smaller (≤ 1%). The red kite population has been recovering; however, modeled lead shot ingestion reduced its annual growth rate from 6.5% to 4%, slowing recovery. If mortality from poisoned baits could be removed, the kite population could potentially increase at a rapid annual rate of 12%. The effects are somewhat higher if ingestion of these substances additionally causes sublethal reproductive impairment. These results have uncertainty but suggest that declining or recovering populations are most sensitive to lead shot or poison ingestion, and removal of poisoned baits can have a positive impact on recovering raptor populations that frequently feed on

  4. Single shot ultrafast dynamic ellipsometry (UDE) of laser-driven shocks in single crystal explosives

    Energy Technology Data Exchange (ETDEWEB)

    Whitley, Von H [Los Alamos National Laboratory; Mcgrane, Shawn D [Los Alamos National Laboratory; Moore, David S [Los Alamos National Laboratory; Eakins, Dan E [Los Alamos National Laboratory; Bolme, Cindy A [Los Alamos National Laboratory

    2009-01-01

    We report on the first experiments to measure states in shocked energetic single crystals with dynamic ellipsometry. We demonstrate that these ellipsometric techniques can produce reasonable Hugoniot values using small amounts of crystalline RDX and PETN. Pressures, particle velocities and shock velocities obtained using shocked ellipsometry are comparable to those found using gas-gun flyer plates and molecular dynamics calculations. The adaptation of the technique from uniform thin films of polymers to thick non-perfect crystalline materials was a significant achievement. Correct sample preparation proved to be a crucial component. Through trial and error, we were able to resolve polishing issues, sample quality problems, birefringence effects and mounting difficulties that were not encountered using thin polymer films.

  5. Single shot three-dimensional pulse sequence for hyperpolarized13C MRI.

    Science.gov (United States)

    Wang, Jiazheng; Wright, Alan J; Hu, De-En; Hesketh, Richard; Brindle, Kevin M

    2017-02-01

    Metabolic imaging with hyperpolarized 13 C-labeled cell substrates is a promising technique for imaging tissue metabolism in vivo. However, the transient nature of the hyperpolarization, and its depletion following excitation, limits the imaging time and the number of excitation pulses that can be used. We describe here a single-shot three-dimensional (3D) imaging sequence and demonstrate its capability to generate 13 C MR images in tumor-bearing mice injected with hyperpolarized [1- 13 C]pyruvate. The pulse sequence acquires a stack-of-spirals at two spin echoes after a single excitation pulse and encodes the kz-dimension in an interleaved manner to enhance robustness to B 0 inhomogeneity. Spectral-spatial pulses are used to acquire dynamic 3D images from selected hyperpolarized 13 C-labeled metabolites. A nominal spatial/temporal resolution of 1.25 × 1.25 × 2.5 mm 3  × 2 s was achieved in tumor images of hyperpolarized [1- 13 C]pyruvate and [1- 13 C]lactate acquired in vivo. Higher resolution in the z-direction, with a different k-space trajectory, was demonstrated in measurements on a thermally polarized [1- 13 C]lactate phantom. The pulse sequence is capable of imaging hyperpolarized 13 C-labeled substrates at relatively high spatial and temporal resolutions and is robust to moderate system imperfections. Magn Reson Med 77:740-752, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  6. Anti-spoof touchless 3D fingerprint recognition system using single shot fringe projection and biospeckle analysis

    Science.gov (United States)

    Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2017-08-01

    Fingerprint is a unique, un-alterable and easily collected biometric of a human being. Although it is a 3D biological characteristic, traditional methods are designed to provide only a 2D image. This touch based mapping of 3D shape to 2D image losses information and leads to nonlinear distortions. Moreover, as only topographic details are captured, conventional systems are potentially vulnerable to spoofing materials (e.g. artificial fingers, dead fingers, false prints, etc.). In this work, we demonstrate an anti-spoof touchless 3D fingerprint detection system using a combination of single shot fringe projection and biospeckle analysis. For fingerprint detection using fringe projection, light from a low power LED source illuminates a finger through a sinusoidal grating. The fringe pattern modulated because of features on the fingertip is captured using a CCD camera. Fourier transform method based frequency filtering is used for the reconstruction of 3D fingerprint from the captured fringe pattern. In the next step, for spoof detection using biospeckle analysis a visuo-numeric algorithm based on modified structural function and non-normalized histogram is proposed. High activity biospeckle patterns are generated because of interaction of collimated laser light with internal fluid flow of the real finger sample. This activity reduces abruptly in case of layered fake prints, and is almost absent in dead or fake fingers. Furthermore, the proposed setup is fast, low-cost, involves non-mechanical scanning and is highly stable.

  7. Near field flow characteristics of the Bjork-Shiley Monostrut valve in a modified single shot valve chamber.

    Science.gov (United States)

    Manning, Keefe B; Przybysz, T Michael; Fontaine, Arnold A; Tarbell, John M; Deutsch, Steven

    2005-01-01

    In certain mechanical heart valves, cavitation has been shown to develop during closure and rebound, leading to valve damage, blood damage, and strokes. Whereas it is uncertain what causes mechanical heart valve related strokes, some evidence suggests that stable bubbles may be the culprits. Previous work has indicated that vortex cavitation may contribute to stable bubble growth. Therefore, in an effort to understand the vortex cavitation, laser Doppler velocimetry data are collected in a plane parallel to and 3 mm away from the major orifice during closure and rebound of a Bjork-Shiley Monostrut mechanical heart valve. A modified single shot chamber is used that incorporates a more realistic near valve geometry than those used in previous studies. The results show the formation of a vortex during closure, which intensifies during rebound and dissipates during the final closing cycle. A regurgitant jet with mean velocities up to 3 m/s through the clearance gap of the valve provides energy to the vortex. During the final closing cycle, the vortex breaks up into asymmetrical, small scale flow patterns. This study provides further evidence that stable bubble formation may stem from the intense vortex cavitation occurring during valve closure and rebound.

  8. Pharmaceutical and immunological evaluation of a single-shot hepatitis B vaccine formulated with PLGA microspheres.

    Science.gov (United States)

    Shi, Li; Caulfield, Michael J; Chern, Rey T; Wilson, Roger A; Sanyal, Gautam; Volkin, David B

    2002-04-01

    A single-shot Hepatitis B vaccine formulation using poly(d,l)-lactide-co-glycolide acid (PLGA) microspheres as a delivery system was examined using a variety of biophysical and biochemical techniques as well as immunological evaluation in C3H mice. PLGA microsphere encapsulation of the Hepatitis B surface antigen (HBsAg), a lipoprotein particle, resulted in good recoveries of protein mass, protein particle conformational integrity, and in vitro antigenicity. Some partial delipidation of the HBsAg, however, was observed. The loading and encapsulation efficiency of HBsAg into the PLGA microspheres were measured along with the morphology and size distribution of the vaccine-loaded PLGA microspheres. The in vitro release kinetics of HBsAg from the PLGA microspheres was evaluated and found to be affected by experimental conditions such as stirring rate. HBsAg showed enhanced storage stability at 37 degrees C in the slightly acidic pH range reported to be found inside PLGA microspheres; thus, the antigen is relatively stable under conditions of temperature and pH that may mimic in vivo conditions. The immunogenicity of the microsphere formulations of HBsAg was compared with conventional aluminum adjuvant formulated HBsAg vaccine in C3H mice. Comparisons were made between aluminum formulations (one and two injections), PLGA microsphere formulations (single injection), and a mixture of aluminum and PLGA microsphere formulations (single injection). The nine-month serum antibody titers indicate that a single injection of a mixture of aluminum and PLGA-formulated HBsAg results in equal or better immune responses than two injections of aluminum-formulated HBsAg vaccine. Based on these in vitro and in vivo studies, it is concluded that HBsAg can be successfully encapsulated and recovered from the PLGA microspheres and a mixture of aluminum-adjuvanted and PLGA-formulated HBsAg can auto-boost an immune response in manner comparable to multiple injections of an aluminum

  9. Reference-free unwarping of single-shot spatiotemporally encoded MRI using asymmetric self-refocused echoes acquisition

    Science.gov (United States)

    Chen, Ying; Chen, Song; Zhong, Jianhui; Chen, Zhong

    2015-05-01

    This paper presents a phase evolution rewinding algorithm for correcting the geometric and intensity distortions in single-shot spatiotemporally encoded (SPEN) MRI with acquisition of asymmetric self-refocused echo trains. Using the field map calculated from the phase distribution of the source image, the off-resonance induced phase errors are successfully rewound through deconvolution. The alias-free partial Fourier transform reconstruction helps improve the signal-to-noise ratio of the field maps and the output images. The effectiveness of the proposed algorithm was validated through 7 T MRI experiments on a lemon, a water phantom, and in vivo rat head. SPEN imaging was evaluated using rapid acquisition by sequential excitation and refocusing (RASER) which produces uniform T2 weighting. The results indicate that the new technique can more robustly deal with the cases in which the images obtained with conventional single-shot spin-echo EPI are difficult to be restored due to serious field variations.

  10. Single-shot photonic time-stretch digitizer using a dissipative soliton-based passively mode-locked fiber laser.

    Science.gov (United States)

    Peng, Di; Zhang, Zhiyao; Zeng, Zhen; Zhang, Lingjie; Lyu, Yanjia; Liu, Yong; Xie, Kang

    2018-03-19

    We demonstrate a single-shot photonic time-stretch digitizer using a dissipative soliton-based passively mode-locked fiber laser. The theoretical analysis and simulation results indicate that the dissipative soliton-based optical source with a flat spectrum relieves the envelope-induced signal distortion, and its high energy spectral density helps to improve the signal-to-noise ratio, both of which are favorable for simplifying the optical front-end architecture of a photonic time-stretch digitizer. By employing a homemade dissipative soliton-based passively mode-locked erbium-doped fiber laser in a single-shot photonic time-stretch digitizer, an effective number of bits of 4.11 bits under an effective sampling rate of 100 GS/s is experimentally obtained without optical amplification in the link and pulse envelope removing process.

  11. Single-shot readout of a superconducting flux qubit with a flux-driven Josephson parametric amplifier

    Science.gov (United States)

    Lin, Z. R.; Inomata, K.; Oliver, W. D.; Koshino, K.; Nakamura, Y.; Tsai, J. S.; Yamamoto, T.

    2013-09-01

    We report single-shot readout of a superconducting flux qubit by using a flux-driven Josephson parametric amplifier (JPA). After optimizing the readout power, gain of the JPA, and timing of the data acquisition, we observe the Rabi oscillations with a contrast of 74%, which is mainly limited by the bandwidth of the JPA and the energy relaxation of the qubit. The observation of quantum jumps between the qubit eigenstates under continuous monitoring indicates the nondestructiveness of the readout scheme.

  12. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  13. The single-shot opto-digitizer; L'optoechantillonneur monocoup

    Energy Technology Data Exchange (ETDEWEB)

    Nail, M.; Gibert, Ph. [CEA/DAM-Ile de France, Dept. de Conception et Realisation des Experimentations (DCRE), 91 - Bruyeres-le-Chatel (France); CEA/DAM-Ile de France, Dept. Laser Puissance, DLP, 91 - Bruyeres-Le-Chatel (France)

    2000-07-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  14. Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging.

    Science.gov (United States)

    Chen, Feiyu; Taviani, Valentina; Tamir, Jonathan I; Cheng, Joseph Y; Zhang, Tao; Song, Qiong; Hargreaves, Brian A; Pauly, John M; Vasanawala, Shreyas S

    2018-04-01

    It is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T 2 decay and partial-Fourier acquisition. To develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. Prospective controlled clinical trial. With Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5×) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. Image quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. A Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. Wave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966. © 2017 International Society for Magnetic Resonance in Medicine.

  15. Long-term persistence of spent lead shot in tundra wetlands

    Science.gov (United States)

    Flint, Paul L.; Schamber, Jason L.

    2010-01-01

    We seeded experimental plots with number 4 lead pellets and sampled these plots for 10 years to assess the settlement rate of pellets in tundra wetland types commonly used by foraging waterfowl. After 10 years, about 10% of pellets remained within 6 cm of the surface, but >50% remained within 10 cm. We predict that spent lead pellets will eventually become unavailable to waterfowl; however, it will likely require >25 years for all pellets to exceed depths at which waterfowl species may forage.

  16. Femtosecond Single-Shot Imaging of Nanoscale Ferromagnetic Order in Co/Pd Multilayers using Resonant X-ray Holography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tianhan; Zhu, Diling; Benny Wu,; Graves, Catherine; Schaffert, Stefan; Rander, Torbjorn; Muller, leonard; Vodungbo, Boris; Baumier, Cedric; Bernstein, David P.; Brauer, Bjorn; Cros, Vincent; Jong, Sanne de; Delaunay, Renaud; Fognini, Andreas; Kukreja, Roopali; Lee, Sooheyong; Lopez-Flores, Victor; Mohanty, Jyoti; Pfau, Bastian; Popescu, 5 Horia

    2012-05-15

    We present the first single-shot images of ferromagnetic, nanoscale spin order taken with femtosecond x-ray pulses. X-ray-induced electron and spin dynamics can be outrun with pulses shorter than 80 fs in the investigated fluence regime, and no permanent aftereffects in the samples are observed below a fluence of 25 mJ/cm{sup 2}. Employing resonant spatially-muliplexed x-ray holography results in a low imaging threshold of 5 mJ/cm{sup 2}. Our results open new ways to combine ultrafast laser spectroscopy with sequential snapshot imaging on a single sample, generating a movie of excited state dynamics.

  17. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  18. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  19. Implications for wildlife and humans of dietary exposure to lead from fragments of lead rifle bullets in deer shot in the UK

    Energy Technology Data Exchange (ETDEWEB)

    Knott, Jeff, E-mail: jeff.knott@rspb.org.uk [Royal Society for the Protection of Birds, The Lodge, Sandy, Bedfordshire SG19 2DL (United Kingdom); Gilbert, Jo; Hoccom, David G. [Royal Society for the Protection of Birds, The Lodge, Sandy, Bedfordshire SG19 2DL (United Kingdom); Green, Rhys E. [Royal Society for the Protection of Birds, The Lodge, Sandy, Bedfordshire SG19 2DL (United Kingdom); Conservation Science Group, Department of Zoology, University of Cambridge, Downing Street, Cambridge CB2 3EJ (United Kingdom)

    2010-12-01

    Lead poisoning caused by ingested spent lead shotgun pellets has long been known to be a cause of unnecessary mortality in waterfowl and has led to legislation limiting its use in many countries. Recent evidence has shown that the problem extends to terrestrial ecosystems and to fragmented rifle bullets eaten by scavengers as well as shotgun pellets. Dietary exposure of human consumers to lead from spent ammunition in game meat also poses potential risks to human health. To assess the degree of fragmentation of lead bullets used to kill wild deer, twelve deer were shot in the thorax using copper-jacketed lead-cored bullets, as part of planned deer management operations. The thoracic region of the eviscerated carcasses and the abdominal viscera of each deer were X-rayed. An average of 356 metal fragments was visible on radiographs of the carcass and 180 fragments in the viscera. The weight of fragments was estimated by reference to an X-rayed scale of fragments of known weight. The average total weight of metal fragments, likely to be mostly lead, was estimated to be 1.2 g for the carcass and 0.2 g for the viscera. The total estimated weight of fragments in the entire carcass was estimated to be 17% of the weight of the bullet. Most fragments were small in size, with those in the viscera being smaller than those in the carcass. Metal fragments in the viscera were sufficiently small that at least 80% of the metallic bullet-derived lead in the viscera would be expected to be ingested by scavenging birds, such as buzzards and eagles, which feed on them.

  20. A single-shot nonlinear autocorrelation approach for time-resolved physics in the vacuum ultraviolet spectral range

    International Nuclear Information System (INIS)

    Rompotis, Dimitrios

    2016-02-01

    In this work, a single-shot temporal metrology scheme operating in the vacuum-extreme ultraviolet spectral range has been designed and experimentally implemented. Utilizing an anti-collinear geometry, a second-order intensity autocorrelation measurement of a vacuum ultraviolet pulse can be performed by encoding temporal delay information on the beam propagation coordinate. An ion-imaging time-of-flight spectrometer, offering micrometer resolution has been set-up for this purpose. This instrument enables the detection of a magnified image of the spatial distribution of ions exclusively generated by direct two-photon absorption in the combined counter-propagating pulse focus and thus obtain the second-order intensity autocorrelation measurement on a single-shot basis. Additionally, an intense VUV light source based on high-harmonic generation has been experimentally realized. It delivers intense sub-20 fs Ti:Sa fifth-harmonic pulses utilizing a loose-focusing geometry in a long Ar gas cell. The VUV pulses centered at 161.8 nm reach pulse energies of 1.1 μJ per pulse, while the corresponding pulse duration is measured with a second-order, fringe-resolved autocorrelation scheme to be 18 ± 1 fs on average. Non-resonant, two-photon ionization of Kr and Xe and three-photon ionization of Ne verify the fifth-harmonic pulse intensity and indicate the feasibility of multi-photon VUV pump/VUV probe studies of ultrafast atomic and molecular dynamics. Finally, the extended functionally of the counter-propagating pulse metrology approach is demonstrated by a single-shot VUV pump/VUV probe experiment aiming at the investigation of ultrafast dissociation dynamics of O 2 excited in the Schumann-Runge continuum at 162 nm.

  1. Supplemental single shot femoral nerve block for total hip arthroplasty: impact on early postoperative care, pain management and lung function.

    Science.gov (United States)

    Wiesmann, T; Steinfeldt, T; Wagner, G; Wulf, H; Schmitt, J; Zoremba, M

    2014-01-01

    Peripheral regional anesthesia is beneficial in the management of postoperative pain in hip surgery, and can also reduce post-operative care unit (PACU) stay. Its opioid-sparing actions may also be beneficial for respiratory mechanics and pulmonary function. The aim of our pilot study was to evaluate the effect of a supplemental single shot femoral block for elective total hip arthroplasty on early respiratory function and postoperative management within the first 24 postoperative hours. We prospectively studied 80 patients undergoing total hip arthroplasty. Written informed consent was obtained after ethics committee approval. Forty patients were randomLy assigned to receive single shot femoral nerve block (FNB) using 15mL bupivacaine 0.25% and 20 mg clonidine while the remainder received standard treatment without nerve block (STN). Premedication and general anesthesia were standardized. Pulse oximetry saturation and spirometric lung function were measured preoperatively (baseline) and at 0.5 h, 2 h, 6 h and 24 h, after extubation breathing room air. PACU surveillance and postoperative pain therapy was standardized. Oxygen saturation and spirometry results were significantly better within the FNB group during the first six postoperative hours. Although VAS scores during the PACU stay did not significantly differ between the study groups, PACU discharge criteria were met earlier in the FNB group (116±40 min [mean±SD] vs. 152±47 min in the STN group). The FNB group exhibited significantly lower VAS scores at 6 and 24 hours. Supplemental single shot femoral nerve block for total hip arthroplasty resulted in earlier PACU discharge capability, improved lung function during the first six hours and better pain control within the first 24 postoperative hours.

  2. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  3. Single shot fringe pattern phase demodulation using Hilbert-Huang transform aided by the principal component analysis.

    Science.gov (United States)

    Trusiak, Maciej; Służewski, Łukasz; Patorski, Krzysztof

    2016-02-22

    Hybrid single shot algorithm for accurate phase demodulation of complex fringe patterns is proposed. It employs empirical mode decomposition based adaptive fringe pattern enhancement (i.e., denoising, background removal and amplitude normalization) and subsequent boosted phase demodulation using 2D Hilbert spiral transform aided by the Principal Component Analysis method for novel, correct and accurate local fringe direction map calculation. Robustness to fringe pattern significant noise, uneven background and amplitude modulation as well as local fringe period and shape variations is corroborated by numerical simulations and experiments. Proposed automatic, adaptive, fast and comprehensive fringe analysis solution compares favorably with other previously reported techniques.

  4. Simultaneous single-shot readout of multi-qubit circuits using a traveling-wave parametric amplifier

    Science.gov (United States)

    O'Brien, Kevin

    Observing and controlling the state of ever larger quantum systems is critical for advancing quantum computation. Utilizing a Josephson traveling wave parametric amplifier (JTWPA), we demonstrate simultaneous multiplexed single shot readout of 10 transmon qubits in a planar architecture. We employ digital image sideband rejection to eliminate noise at the image frequencies. We quantify crosstalk and infidelity due to simultaneous readout and control of multiple qubits. Based on current amplifier technology, this approach can scale to simultaneous readout of at least 20 qubits. This work was supported by the Army Research Office.

  5. Real time quantitative phase microscopy based on single-shot transport of intensity equation (ssTIE) method

    Science.gov (United States)

    Yu, Wei; Tian, Xiaolin; He, Xiaoliang; Song, Xiaojun; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-08-01

    Microscopy based on transport of intensity equation provides quantitative phase distributions which opens another perspective for cellular observations. However, it requires multi-focal image capturing while mechanical and electrical scanning limits its real time capacity in sample detections. Here, in order to break through this restriction, real time quantitative phase microscopy based on single-shot transport of the intensity equation method is proposed. A programmed phase mask is designed to realize simultaneous multi-focal image recording without any scanning; thus, phase distributions can be quantitatively retrieved in real time. It is believed the proposed method can be potentially applied in various biological and medical applications, especially for live cell imaging.

  6. Development and Characterization of Two-Dimensional Gratings for Single-Shot X-ray Phase-Contrast Imaging

    Directory of Open Access Journals (Sweden)

    Margarita Zakharova

    2018-03-01

    Full Text Available Single-shot grating-based phase-contrast imaging techniques offer additional contrast modalities based on the refraction and scattering of X-rays in a robust and versatile configuration. The utilization of a single optical element is possible in such methods, allowing the shortening of the acquisition time and increasing flux efficiency. One of the ways to upgrade single-shot imaging techniques is to utilize customized optical components, such as two-dimensional (2D X-ray gratings. In this contribution, we present the achievements in the development of 2D gratings with UV lithography and gold electroplating. Absorption gratings represented by periodic free-standing gold pillars with lateral structure sizes from 5 µm to 25 µm and heights from 5 µm to 28 µm have shown a high degree of periodicity and defect-free patterns. Grating performance was tested in a radiographic setup using a self-developed quality assessment algorithm based on the intensity distribution histograms. The algorithm allows the final user to estimate the suitability of a specific grating to be used in a particular setup.

  7. Optimization of laser energy deposition for single-shot high aspect-ratio microstructuring of thick BK7 glass

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, Valerio; Grigutis, Robertas [Dipartimento di Scienza e Alta Tecnologia, University of Insubria, Via Valleggio 11, I-22100 Como (Italy); Jukna, Vytautas [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); LOA, ENSTA-ParisTech, CNRS, Ecole Polytechnique, Université Paris Saclay, F-91762 Palaiseau (France); Couairon, Arnaud [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); Di Trapani, Paolo [Dipartimento di Scienza e Alta Tecnologia, University of Insubria and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy); Jedrkiewicz, Ottavia, E-mail: ottavia.jedrkiewicz@ifn.cnr.it [Istituto di Fotonica e Nanotecnologie, CNR and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy)

    2016-07-07

    We investigate the generation of high aspect ratio microstructures across 0.7 mm thick glass by means of single shot Bessel beam laser direct writing. We study the effect on the photoinscription of the cone angle, as well as of the energy and duration of the ultrashort laser pulse. The aim of the study is to optimize the parameters for the writing of a regular microstructure due to index modification along the whole sample thickness. By using a spectrally resolved single pulse transmission diagnostics at the output surface of the glass, we correlate the single shot material modification with observations of the absorption in different portions of the retrieved spectra, and with the absence or presence of spectral modulation. Numerical simulations of the evolution of the Bessel pulse intensity and of the energy deposition inside the sample help us interpret the experimental results that suggest to use picosecond pulses for an efficient and more regular energy deposition. Picosecond pulses take advantage of nonlinear plasma absorption and avoid temporal dynamics effects which can compromise the stationarity of the Bessel beam propagation.

  8. Detection of lead nanoparticles in game meat by single particle ICP-MS following use of lead-containing bullets.

    Science.gov (United States)

    Kollander, Barbro; Widemo, Fredrik; Ågren, Erik; Larsen, Erik H; Loeschner, Katrin

    2017-03-01

    This study investigated whether game meat may contain nanoparticles of lead from ammunition. Lead nanoparticles in the range 40 to 750 nm were detected by ICP-MS in single particle mode in game shot with lead-containing bullets. The median diameter of the detected nanoparticles was around 60 nm. The particle mass concentration ranged from 290 to 340 ng/g meat and the particle number concentrations from 27 to 50 million particles/g meat. The size limit of detection strongly depended on the level of dissolved lead and was in the range of 40 to 80 nm. In game meat sampled more than 10 cm away from the wound channel, no lead particles with a diameter larger than 40 nm were detected. In addition to dissolved lead in meat that originated from particulates, the presence of lead nano particles in game meat represents a hitherto unattended source of lead with a largely unknown toxicological impact to humans. Graphical Abstract Detection of lead nanoparticles in game meat by single particle ICP-MS following use of leadcontaining bullets.

  9. Absolute Quantification of Rifampicin by MALDI Imaging Mass Spectrometry Using Multiple TOF/TOF Events in a Single Laser Shot.

    Science.gov (United States)

    Prentice, Boone M; Chumbley, Chad W; Caprioli, Richard M

    2017-01-01

    Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R 2 ) and accuracy (>93% quality controls, errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%. Graphical Abstract ᅟ.

  10. Distribution of lead in single atmospheric particles

    Science.gov (United States)

    Murphy, D. M.; Hudson, P. K.; Cziczo, D. J.; Gallavardin, S.; Froyd, K. D.; Johnston, M. V.; Middlebrook, A. M.; Reinard, M. S.; Thomson, D. S.; Thornberry, T.; Wexler, A. S.

    2007-06-01

    Three independent single particle mass spectrometers measured Pb in individual aerosol particles. These data provide unprecedented sensitivity and statistical significance for the measurement of Pb in single particles. This paper explores the reasons for the frequency of Pb in fine particles now that most gasoline is unleaded. Trace amounts of Pb were found in 5 to 25% of 250 to 3000 nm diameter particles sampled by both aircraft and surface instruments in the eastern and western United States. Over 5% of particles at a mountain site in Switzerland contained Pb. Particles smaller than 100 nm with high Pb content were also observed by an instrument that was only operated in urban areas. Lead was found on all types of particles, including Pb present on biomass burning particles from remote fires. Less common particles with high Pb contents contributed a majority of the total amount of Pb. Single particles with high Pb content often also contained alkali metals, Zn, Cu, Sn, As, and Sb. The association of Pb with Zn and other metals is also found in IMPROVE network filter data from surface sites. Sources of airborne Pb in the United States are reviewed for consistency with these data. The frequent appearance of trace Pb is consistent with widespread emissions of fine Pb particles from combustion sources followed by coagulation with larger particles during long-range transport. Industrial sources that directly emit Pb-rich particles also contribute to the observations. Clean regions of the western United States show some transport of Pb from Asia but most Pb over the United States comes from North American sources. Resuspension of Pb from soil contaminated by the years of leaded gasoline was not directly apparent.

  11. Generating multiple contrasts using single-shot radial T1 sensitive and insensitive steady-state imaging.

    Science.gov (United States)

    Benkert, Thomas; Bartsch, Andreas J; Blaimer, Martin; Jakob, Peter M; Breuer, Felix A

    2015-06-01

    Recently, the (Resolution Enhanced-) T1 insensitive steady-state imaging (TOSSI) approach has been proposed for the fast acquisition of T2 -weighted images. This has been achieved by balanced steady-state free precession (bSSFP) imaging between unequally spaced inversion pulses. The purpose of this work is to present an extension of this technique, considerably increasing both the efficiency and possibilities of TOSSI. A radial trajectory in combination with an appropriate view-sharing reconstruction is used. Because each projection traverses the contrast defining k-space center, several different contrasts can be extracted from a single-shot measurement. These contrasts include various T2 -weightings and T2 /T1 -weighting if an even number of inversion pulses is used, while an odd number allow the generation of several images with predefined tissue types cancelled. The approach is validated for brain and abdominal imaging at 3.0 Tesla. Results are compared with RE-TOSSI, bSSFP, and turbo spin-echo images and are shown to provide similar contrasts in a fraction of scan time. Furthermore, the potential utility of the approach is illustrated by images obtained from a brain tumor patient. Radial T1 sensitive and insensitive steady-state imaging is able to generate multiple contrasts out of one single-shot measurement in a short scan time. © 2014 Wiley Periodicals, Inc.

  12. Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Mo, M. Z., E-mail: mmo09@slac.stanford.edu; Shen, X.; Chen, Z.; Li, R. K.; Dunning, M.; Zheng, Q.; Weathersby, S. P.; Reid, A. H.; Coffee, R.; Makasyuk, I.; Edstrom, S.; McCormick, D.; Jobe, K.; Hast, C.; Glenzer, S. H.; Wang, X. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Sokolowski-Tinten, K. [Faculty of Physics and Centre for Nanointegration Duisburg-Essen, University of Duisburg-Essen, Lotharstrasse 1, D-47048 Duisburg (Germany)

    2016-11-15

    We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

  13. Single-shot EPI with Nyquist ghost compensation: Interleaved Dual-Echo with Acceleration (IDEA) EPI

    Science.gov (United States)

    Poser, Benedikt A; Barth, Markus; Goa, Pål-Erik; Deng, Weiran; Stenger, V Andrew

    2012-01-01

    Echo planar imaging is most commonly used for BOLD fMRI, owing to its sensitivity and acquisition speed. A major problem with EPI is Nyquist (N/2) ghosting, most notably at high field. EPI data are acquired under an oscillating readout gradient and hence vulnerable to gradient imperfections such as eddy current delays and off-resonance effects, as these cause inconsistencies between odd and even k-space lines after time reversal. We propose a straightforward and pragmatic method herein termed Interleaved Dual Echo with Acceleration (IDEA) EPI: Two k-spaces (echoes) are acquired under the positive and negative readout lobes, respectively, by performing phase blips only before alternate readout gradients. From these two k-spaces, two almost entirely ghost free images per shot can be constructed, without need for phase correction. The doubled echo train length can be compensated by parallel imaging and/or partial Fourier acquisition. The two k-spaces can either be complex-averaged during reconstruction, which results in near-perfect cancellation of residual phase errors, or reconstructed into separate images. We demonstrate the efficacy of IDEA EPI and show phantom and in vivo images at both 3 and 7 Tesla. PMID:22411762

  14. Blood Bupivacaine Concentrations After a Combined Single-Shot Sciatic Block and a Continuous Femoral Nerve Block in Pediatric Patients: A Prospective Observational Study.

    Science.gov (United States)

    Suresh, Santhanam; De Oliveira, Gildasio S

    2017-05-01

    We evaluated blood bupivacaine concentrations in children having a single-shot sciatic and continuous femoral blocks after anterior cruciate ligament repair. Dried blood spot samples were analyzed for bupivacaine levels at 0, 5, 15, 30, 60, and 120 minutes and 4, 24, and 48 hours. The highest 99% upper confidence interval limit was 135 ng/mL at the 4-hour evaluation point. The 99% upper confidence interval was below potentially toxic levels (1500 ng/mL) across all sampling times. The risk of local anesthetic toxicity in pediatric patients receiving single-shot sciatic and continuous femoral nerve blocks is very low.

  15. Single-shot spectro-temporal characterization of XUV pulses from a seeded free-electron laser

    Science.gov (United States)

    de Ninno, Giovanni; Gauthier, David; Mahieu, Benoît; Ribič, Primož Rebernik; Allaria, Enrico; Cinquegrana, Paolo; Danailov, Miltcho Bojanov; Demidovich, Alexander; Ferrari, Eugenio; Giannessi, Luca; Penco, Giuseppe; Sigalotti, Paolo; Stupar, Matija

    2015-08-01

    Intense ultrashort X-ray pulses produced by modern free-electron lasers (FELs) allow one to probe biological systems, inorganic materials and molecular reaction dynamics with nanoscale spatial and femtoscale temporal resolution. These experiments require the knowledge, and possibly the control, of the spectro-temporal content of individual pulses. FELs relying on seeding have the potential to produce spatially and temporally fully coherent pulses. Here we propose and implement an interferometric method, which allows us to carry out the first complete single-shot spectro-temporal characterization of the pulses, generated by an FEL in the extreme ultraviolet spectral range. Moreover, we provide the first direct evidence of the temporal coherence of a seeded FEL working in the extreme ultraviolet spectral range and show the way to control the light generation process to produce Fourier-limited pulses. Experiments are carried out at the FERMI FEL in Trieste.

  16. Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

    Directory of Open Access Journals (Sweden)

    Taito Osaka

    2017-11-01

    Full Text Available Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at sub-ångström scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 ± 0.7 fs, which agrees with that expected from the single-shot spectral information. This is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from ångström to nanometre spatial scales.

  17. Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique

    International Nuclear Information System (INIS)

    Nasu, Katsuhiro; Kuroki, Yoshihumi; Murakami, Koji; Nawano, Shigeru; Kuroki, Seiko; Moriyama, Noriyuki

    2004-01-01

    We wanted to determine the feasibility of diffusion-weighted single shot echo planar imaging using a sensitivity encoding diffusion weighted imaging (SENSE-DWI) technique in depicting colorectal cancer. Forty-two patients with sigmoid colon cancer and rectal cancer, all proven pathologically, were examined on T2-turbo spin echo (TSE) and SENSE-DWI. No bowel preparation was performed before examination. The b-factors used in SENSE-DWI were zero and 1000 s/mm 2 . In 10 randomly selected cases, the images whose b-factors were 250 and 500 s/mm 2 were also obtained. The reduction factor of SENSE was 2.0 in all sequences. Two radiologists evaluated the obtained images from the viewpoints of tumor detectability, image distortion and misregistration of the tumors. The apparent diffusion coefficients (ADCs) of the tumors and urine in the urinary bladders in each patient were measured to evaluate the correlation between ADC and pathological classification of each tumor. All tumors were depicted hyperintensely on SENSE-DWI. Even though single shot echo planar imaging (EPI) was used, the image distortion and misregistration was quite pronounced because of simultaneous use of SENSE. On SENSE-DWI whose b-factor was 1000 s/mm 2 , the normal colon wall and feces were always hypointense and easily differentiated from the tumors. The mean ADC value of each tumor was 1.02±0.1 (x 10 -3 ) mm 2 /s. No overt correlation can be pointed out between ADC and pathological classification of each tumor. SENSE-DWI is a feasible method for depicting colorectal cancer. SENSE-DWI provides strong contrast among colorectal cancers, normal rectal wall and feces. (authors)

  18. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. The Physics of Shot Towers

    Science.gov (United States)

    Lipscombe, Trevor C.; Mungan, Carl E.

    2012-01-01

    In the late 18th and throughout the 19th century, lead shot for muskets was prepared by use of a shot tower. Molten lead was poured from the top of a tower and, during its fall, the drops became spherical under the action of surface tension. In this article, we ask and answer the question: "How does the size of the lead shot depend on the height…

  20. Real-Time, Single-Shot Temporal Measurements of Short Electron Bunches, Terahertz CSR and FEL Radiation

    CERN Document Server

    Berden, G; Van der Meer, A F G

    2005-01-01

    Electro-optic detection of the Coulomb field of electron bunches is a promising technique for single-shot measurements of the bunch length and shape in the sub-picosecond time domain. This technique has been applied to the measurement of 50 MeV electron bunches in the FELIX free electron laser, showing the longitudinal profile of single bunches of around 650 fs FWHM [Phys. Rev. Lett. 93, 114802 (2004)]. The method is non-destructive and real-time, and therefore ideal for online monitoring of the longitudinal shape of single electron bunches. At FELIX we have used it for real-time optimization of sub-picosecond electron bunches. Electro-optic detection has also been used to measure the electric field profiles of far-infrared (or terahertz) optical pulses generated by the relativistic electrons. We have characterised the far-infrared output of the free electron laser, and more recently, we have measured the temporal profile of terahertz optical pulses generated at one of the bending magnets.

  1. Diffusion-weighted imaging of the sellar region: A comparison study of BLADE and single-shot echo planar imaging sequences

    Energy Technology Data Exchange (ETDEWEB)

    Yiping, Lu [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Hui, Liu [MR Collaboration NE Asia, Siemens Healthcare, Siemens Ltd., China, Shanghai 201318 (China); Kun, Zhou [MR PLM APPL, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen 518057 (China); Daoying, Geng, E-mail: GengdaoyingGDY@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Bo, Yin, E-mail: yinbo7@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China)

    2014-07-15

    Purpose: The purpose of this study is to compare BLADE diffusion-weighted imaging (DWI) with single-shot echo planar imaging (EPI) DWI on the aspects of feasibility of imaging the sellar region and image quality. Methods: A total of 3 healthy volunteers and 52 patients with suspected lesions in the sellar region were included in this prospective intra-individual study. All exams were performed at 3.0 T with a BLADE DWI sequence and a standard single-shot EP-DWI sequence. Phantom measurements were performed to measure the objective signal-to-noise ratio (SNR). Two radiologists rated the image quality according to the visualisation of the internal carotid arteries, optic chiasm, pituitary stalk, pituitary gland and lesion, and the overall image quality. One radiologist measured lesion sizes for detecting their relationship with the image score. Results: The SNR in BLADE DWI sequence showed no significant difference from the single-shot EPI sequence (P > 0.05). All of the assessed regions received higher scores in BLADE DWI images than single-shot EP-DWI.

  2. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Lilly, Michael; Curry, Matthew; Carr, Stephen; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will introduce two new amplifier topologies that provide excellent gain versus power tradeoffs using silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs). The AC HBT allows in-situ adjustment of power dissipation during an experiment and can provide gain in the millikelvin temperature regime while dissipating less than 500 nW. The AC Current Amplifier maximizes gain at nearly 800 A/A. We will also show results of using these amplifiers with SETs at 4 K. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout.

  3. Poloxamer 407-chitosan grafted thermoresponsive hydrogels achieve synchronous and sustained release of antigen and adjuvant from single-shot vaccines.

    Science.gov (United States)

    Bobbala, Sharan; Gibson, Blake; Gamble, Allan B; McDowell, Arlene; Hook, Sarah

    2018-03-02

    Sustained release vaccine delivery systems may enhance the immunogenicity of subunit vaccines and reduce the need for multiple vaccinations. The aim of this study was to develop a thermoresponsive hydrogel using poloxamer 407-chitosan (CP) grafted copolymer as a delivery system for single-shot sustained release vaccines. The CP copolymer was synthesized using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and N-hydroxysuccinimide (NHS) chemistry. The CP copolymer was a free flowing solution at ambient temperature and transformed rapidly into a gel at body temperature. The hydrogels were loaded with vaccine antigen and adjuvants or the vaccine components were encapsulated in poly (lactic-co-glycolic acid) nanoparticles (PLGA-NP) in order to ensure synchronous release. The CP hydrogels were stable for up to 18 days in vitro. Release of both nanoparticles and the individual components was complete, with release of the individual components being modulated by incorporation into nanoparticles. In vivo, a single dose of CP hydrogel vaccine induced strong, long lasting, cellular and humoral responses that could protect against the development of tumors in a murine melanoma model. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  4. The value of single-shot black-blood MR imaging for mapping of the coronary arteries: a comparison of four different orientations during breath-holding and free breathing.

    NARCIS (Netherlands)

    Holland, A.E.; Engelbrecht, M.R.W.; Barentsz, J.O.; Heijstraten, F.M.J.; Goldfarb, J.W.

    2002-01-01

    The value of ECG-gated single-shot black-blood MR imaging for rapid visualization of the origin and course of the coronary arteries was investigated. The study population included 28 patients with known or suspected cardiac disease. ECG-gated single-shot black-blood MR acquisitions were acquired in

  5. Single-shot X-ray phase-contrast imaging using two-dimensional gratings

    Energy Technology Data Exchange (ETDEWEB)

    Sato, Genta; Itoh, Hidenosuke; Nagai, Kentaro; Nakamura, Takashi; Yamaguchi, Kimiaki; Kondoh, Takeshi; Handa, Soichiro; Ouchi, Chidane; Teshima, Takayuki; Setomoto, Yutaka; Den, Toru [Frontier Research Center, Corporate R and D Headquarters, Canon Inc., 3-30-2 Shimomaruko, Ohta-ku, Tokyo 146-8501 (Japan); Optics Technology Development Center, Corporate R and D Headquarters, Canon Inc., 23-10, Kiyohara-Kogyodanchi, Utsunomiya Tochigi 321-3231 (Japan); Nanotechnology R and D Center, Corporate R and D Headquarters, Canon Inc., 3-30-2 Shimomaruko, Ohta-ku, Tokyo 146-8501 (Japan)

    2012-07-31

    We developed a two-dimensional gratings-based X-ray interferometer that requires only a single exposure for clinical radiography. The interferometer consisted of a checkerboard phase grating for {pi} phase modulation and a latticed amplitude grating. Using a synchrotron radiation source, the phase grating modulates the X-rays and generates a self-image, transformed to a moire fringe by the amplitude grating. To allow use of a conventional X-ray tube, the latticed source grating was installed downstream from the X-ray tube. Differential phase-contrast and scattering images in two orthogonal directions were obtained by Fourier analysis of the single moire fringe image and an absorption image. Results show that characteristic features of soft tissue in two orthogonal directions were clearly shown in the differential phase-contrast images.

  6. Ankle Block vs Single-Shot Popliteal Fossa Block as Primary Anesthesia for Forefoot Operative Procedures: Prospective, Randomized Comparison.

    Science.gov (United States)

    Schipper, Oliver N; Hunt, Kenneth J; Anderson, Robert B; Davis, W Hodges; Jones, Carroll P; Cohen, Bruce E

    2017-11-01

    Postoperative pain is often difficult to control with oral medications, requiring large doses of opioid analgesia. Regional anesthesia may be used for primary anesthesia, reducing the need for general anesthetic and postoperative pain medication requirements in the immediate postoperative period. The purpose of this study was to compare the analgesic effects of an ankle block (AB) to a single-shot popliteal fossa block (PFB) for patients undergoing orthopedic forefoot procedures. All patients having elective outpatient orthopedic forefoot procedures were invited to participate in the study. Patients were prospectively randomized to receive either an ultrasound-guided AB or PFB by a board-certified anesthesiologist prior to their procedure. Intraoperative conversion to general anesthesia and postanesthesia care unit (PACU) opioid requirements were recorded. Postoperative pain was assessed using the visual analog scale (VAS) at regular time intervals until 8 am on postoperative day (POD) 2. Patients rated the effectiveness of the block on a 1 to 5 scale, with 5 being very effective. A total of 167 patients participated in the study with 88 patients (53%) receiving an AB and 79 (47%) receiving a single-shot PFB. There was no significant difference in the rate of conversion to general anesthesia between the 2 groups (13.6% [12/88] AB vs 12.7% [10/79] PFB). PACU morphine requirements and doses were significantly reduced in the PFB group ( P = .004) when compared to the AB group. The VAS was also significantly lower for the PFB patients at 10 pm on POD 0 (4.6 vs 1.6, P PFB 10.1%, P = .51) and there were no significant differences in residual sensory paresthesias (AB 2.3% [2/88] vs PFB 5.1% [4/79], P = .29), motor loss (0% vs 0%), or block site pain and/or erythema (AB 6.9% [6/88] vs PFB 5.1% [4/79], P = .44). The analgesic effect of the PFB lasted significantly longer when compared to the ankle block (AB 14.5 hours vs PFB 20.9 hours, P PFB 4.82/5, P = .68). Regional

  7. FLASH free-electron laser single-shot temporal diagnostic: terahertz-field-driven streaking.

    Science.gov (United States)

    Ivanov, Rosen; Liu, Jia; Brenner, Günter; Brachmanski, Maciej; Düsterer, Stefan

    2018-01-01

    The commissioning of a terahertz-field-driven streak camera installed at the free-electron laser (FEL) FLASH at DESY in Hamburg, being able to deliver photon pulse duration as well as arrival time information with ∼10 fs resolution for each single XUV FEL pulse, is reported. Pulse durations between 300 fs and terahertz-streaking setup was operated simultaneously to an alternative method to determine the FEL pulse duration based on spectral analysis. FLASH pulse duration derived from simple spectral analysis is in good agreement with that from terahertz-streaking measurement.

  8. Comparing SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Curry, Matthew; Carr, Stephen; Mounce, Andrew; Jock, Ryan; Sharma, Peter; Bureau-Oxton, Chloe; Rudolph, Martin; Hardin, Terry; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will compare two amplifiers based on single-transistor circuits implemented with silicon germanium heterojunction bipolar transistors. Both amplifiers provide gain at low power levels, but the dynamics of each circuit vary significantly. We will explore the gain mechanisms, linearity, and noise of each circuit and explain the situations in which each amplifier is best used. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  9. Thermomechanical measurements of lead halide single crystals

    Czech Academy of Sciences Publication Activity Database

    Nitsch, Karel; Rodová, Miroslava

    2002-01-01

    Roč. 234, č. 2 (2002), s. 701-709 ISSN 0370-1972 R&D Projects: GA AV ČR IAA2010926 Institutional research plan: CEZ:AV0Z1010914 Keywords : PbX 2 (X=Cl, Br, I) * coefficients of linear thermal expansion * polymorphism in lead halides Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.930, year: 2002

  10. Development of Laser Rifle Trainer with Full Shot Imitation

    OpenAIRE

    Bansevicius, Ramutis; Fedaravicius, Algimantas; Ostasevicius, Vytautas; Ragulskis, Minvydas

    2004-01-01

    Laser trainers are effective tools for shot and sportsmen training. However, the majority of trainers have neither realistic recoil nor sound imitation systems. The objective of the development of laser rifle trainer with full shot imitation was to investigate and simulate the recoil of combat weapons under single and serial shooting regimes so that the training weapons could simulate complete recoil and sound imitation.Theoretical and experimental investigations lead to the development of sh...

  11. Magnetic resonance urography in pediatrics: utilization of ultrafast single-shot spin echo sequences; Urografia por resonancia magnetic en pediatria: utilizacion de las secuencias ultrarrapidas single shot en eco del espin

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C.; Martin, J.; Duran, C. [Unidad de Diagnostico por la Imagen de Alta Tecnologia (UDIAT). Sabadell (Spain); Rigol, S.; Rojo, J. C. [Corporacion Sanatiaria Parc Tauli. Sabadell (Spain)

    1999-07-01

    To determine the value of magnetic resonance urography (MRU) using ultrafast single-shot (SS) rapid acquisition with relaxation enhancement (RARE) and half-Fourier (HF) SS-RARE (SS-HF-RARE or HASTE) in the evaluation of congenital urinary tract anomalies in pediatric patients, and their possible application as alternatives to intravenous urography (IVU). Eighteen children (11 boys and 7 girls) aged 2 months to 15 years (mean: 5 years) with a total of 19 congenital urinary tract anomalies were studies by MU using SS-RARE and HASTE sequences in a 1 Tesla scanner. All the patients had previously been studies by ultrasound (US) and IVU. Twelve patients required anesthesia. The images were acquired by means of a HASTE sequence with multisection technique (TR, infinite; TE{sub e}f, 87 msec; echo train, 128; interval between echoes, 10.9 msec; total acquisition time, 13 sections/12 seconds), and SS-RARE (TR, infinite; TE{sub e}f, 1.100 msec; echo train, 240, and acquisition time, 7 seconds). Four radiologists evaluated the images independently; two who reviewed the IV images in consensus and two who reviewed the MRU images in consensus. The images were evaluated to assess the dilatation of the urinary tract and their utility in detecting the level and cause of the obstruction. MRU images revealed the urinary tract dilation, the level of the obstruction and the type of anomaly in 18 patients (100%), while IVU provided this information in only 10 [ sensitivity, 53%, 95% confidence interval (29%, 76%)]. The mean time required for MRU was 20 minutes (range: 7 to 30 minutes), while that of IVU was 1,242 minutes (range: 45 to 1,440 minutes). MRU using ultrafast single-short spin echo sequences is a rapid and effective technique that permits and excellent evaluation of congenital urinary tract anomalies in pediatric patients and does not require the administration of contrast media or ionizing radiation. (Author) 10 refs.

  12. Simple and Reproducible Sample Preparation for Single-Shot Phosphoproteomics with High Sensitivity

    DEFF Research Database (Denmark)

    Jersie-Christensen, Rosa R.; Sultan, Abida; Olsen, Jesper V

    2016-01-01

    The traditional sample preparation workflow for mass spectrometry (MS)-based phosphoproteomics is time consuming and usually requires multiple steps, e.g., lysis, protein precipitation, reduction, alkylation, digestion, fractionation, and phosphopeptide enrichment. Each step can introduce chemical...... artifacts, in vitro protein and peptide modifications, and contaminations. Those often result in sample loss and affect the sensitivity, dynamic range and accuracy of the mass spectrometric analysis. Here we describe a simple and reproducible phosphoproteomics protocol, where lysis, denaturation, reduction......, and alkylation are performed in a single step, thus reducing sample loss and increasing reproducibility. Moreover, unlike standard cell lysis procedures the cell harvesting is performed at high temperatures (99 °C) and without detergents and subsequent need for protein precipitation. Phosphopeptides are enriched...

  13. Sub-Shot-Noise Transmission Measurement Enabled by Active Feed-Forward of Heralded Single Photons

    Science.gov (United States)

    Sabines-Chesterking, J.; Whittaker, R.; Joshi, S. K.; Birchall, P. M.; Moreau, P. A.; McMillan, A.; Cable, H. V.; O'Brien, J. L.; Rarity, J. G.; Matthews, J. C. F.

    2017-07-01

    Harnessing the unique properties of quantum mechanics offers the possibility of delivering alternative technologies that can fundamentally outperform their classical counterparts. These technologies deliver advantages only when components operate with performance beyond specific thresholds. For optical quantum metrology, the biggest challenge that impacts on performance thresholds is optical loss. Here, we demonstrate how including an optical delay and an optical switch in a feed-forward configuration with a stable and efficient correlated photon-pair source reduces the detector efficiency required to enable quantum-enhanced sensing down to the detection level of single photons and without postselection. When the switch is active, we observe a factor of improvement in precision of 1.27 for transmission measurement on a per-input-photon basis compared to the performance of a laser emitting an ideal coherent state and measured with the same detection efficiency as our setup. When the switch is inoperative, we observe no quantum advantage.

  14. Single shot of 17D vaccine may not confer life-long protection against yellow fever.

    Science.gov (United States)

    Vasconcelos, Pedro Fc

    2018-02-01

    The yellow fever (YF) vaccine has been used since the 1930s to prevent YF, which is a severe infectious disease caused by the yellow fever virus (YFV), and mainly transmitted by Culicidae mosquitoes from the genera Aedes and Haemagogus . Until 2013, the World Health Organization (WHO) recommended the administration of a vaccine dose every ten years. A new recommendation of a single vaccine dose to confer life-long protection against YFV infection has since been established. Recent evidence published elsewhere suggests that at least a second dose is needed to fully protect against YF disease. Here, we discuss the feasibility of administering multiple doses, the necessity for a new and modern vaccine, and recommend that the WHO conveys a meeting to discuss YFV vaccination strategies for people living in or travelling to endemic areas.

  15. Spectrally resolved single-shot wavefront sensing of broadband high-harmonic sources

    Science.gov (United States)

    Freisem, L.; Jansen, G. S. M.; Rudolf, D.; Eikema, K. S. E.; Witte, S.

    2018-03-01

    Wavefront sensors are an important tool to characterize coherent beams of extreme ultraviolet radiation. However, conventional Hartmann-type sensors do not allow for independent wavefront characterization of different spectral components that may be present in a beam, which limits their applicability for intrinsically broadband high-harmonic generation (HHG) sources. Here we introduce a wavefront sensor that measures the wavefronts of all the harmonics in a HHG beam in a single camera exposure. By replacing the mask apertures with transmission gratings at different orientations, we simultaneously detect harmonic wavefronts and spectra, and obtain sensitivity to spatiotemporal structure such as pulse front tilt as well. We demonstrate the capabilities of the sensor through a parallel measurement of the wavefronts of 9 harmonics in a wavelength range between 25 and 49 nm, with up to lambda/32 precision.

  16. Observation of single artificial atom optical bi-stability and its application to single-shot readout in circuit quantum electrodynamics

    Science.gov (United States)

    Sun, Luyan; Ginossar, Eran; Guy, Mikhael; Reed, Matthew; Paik, Hanhee; Bishop, Lev S.; Sears, Adam; Petrenko, Andrei; Brecht, Teresa; Frunzio, Luigi; Girvin, Steven; Schoelkopf, Robert

    2012-02-01

    The high power transient behavior of superconducting qubit-cavity systems has recently been used to perform high fidelity readout of transmon qubits [1]. We show that in the steady state, the system exhibits a bi-stable behavior that can be observed on the single-shot level, with the cavity state switching stochastically between dim and bright states. The switching times are shown to be long compared to the cavity and qubit lifetimes. Some features of the bi-stability can be explained by mean field theory, while its switching dynamics is studied with large scale simulations. Understanding these dynamics will be crucial for studying the transient response, an essential aspect of the qubit readout. We will discuss progress on optimizing readout by shaping the measurement pulse. [4pt] [1] M. D. Reed, L. DiCarlo, B. R. Johnson, L. Sun, D. I. Schuster, L. Frunzio, and R. J. Schoelkopf, Phys. Rev. Lett. 105, 173601 (2010)

  17. Fast and robust automatic calibration for single-shot dual-wavelength digital holography based on speckle displacements.

    Science.gov (United States)

    Khodadad, Davood; Bergström, Per; Hällstig, Emil; Sjödahl, Mikael

    2015-06-01

    The objective of this paper is to describe a fast and robust automatic single-shot dual-wavelength holographic calibration method that can be used for online shape measurement applications. We present a model of the correction in two terms for each lobe, one to compensate the systematic errors caused by off-axis angles and the other for the curvature of the reference waves, respectively. Each hologram is calibrated independently without a need for an iterative procedure or information of the experimental set-up. The calibration parameters are extracted directly from speckle displacements between different reconstruction planes. The parameters can be defined as any fraction of a pixel to avoid the effect of quantization. Using the speckle displacements, problems associated with phase wrapping is avoided. The procedure is shown to give a shape accuracy of 34 μm using a synthetic wavelength of 1.1 mm for a measurement on a cylindrical test object with a trace over a field of view of 18  mm×18  mm.

  18. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout

    Science.gov (United States)

    Sukachev, D. D.; Sipahigil, A.; Nguyen, C. T.; Bhaskar, M. K.; Evans, R. E.; Jelezko, F.; Lukin, M. D.

    2017-12-01

    The negatively charged silicon-vacancy (SiV- ) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (˜250 ns ) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV- electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV- symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV- spin with 89% fidelity. Coherent control of the SiV- spin with microwave fields is used to demonstrate a spin coherence time T2 of 13 ms and a spin relaxation time T1 exceeding 1 s at 100 mK. These results establish the SiV- as a promising solid-state candidate for the realization of quantum networks.

  19. Single-shot T1 mapping of the corpus callosum: A rapid characterization of fiber bundle anatomy

    Directory of Open Access Journals (Sweden)

    Sabine eHofer

    2015-05-01

    Full Text Available Using diffusion-tensor MRI and fiber tractography the topographic organization of the corpus callosum (CC has been described to comprise 5 segments with fibers projecting into prefrontal (I, premotor and supplementary motor (II, primary motor (III, and primary sensory areas (IV, as well as into parietal, temporal, and occipital cortical areas (V. In order to more rapidly characterize the underlying anatomy of these segments, this study used a novel single-shot T1 mapping method to quantitatively determine T1 relaxation times in the human CC. A region-of-interest analysis revealed a tendency for the lowest T1 relaxation times in the genu and the highest T1 relaxation times in the somatomotor region of the CC. This observation separates regions dominated by myelinated fibers with large diameters (somatomotor area from densely packed smaller axonal bundles (genu with less myelin. The results indicate that characteristic T1 relaxation times in callosal profiles provide an additional means to monitor differences in fiber anatomy, fiber density, and gray matter in respective neocortical areas. In conclusion, rapid T1 mapping allows for a characterization of the axonal architecture in an individual CC in less than 10 s. The approach emerges as a valuable means for studying neocortical brain anatomy with possible implications for the diagnosis of neurodegenerative processes.

  20. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    International Nuclear Information System (INIS)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao

    1999-01-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  1. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    Energy Technology Data Exchange (ETDEWEB)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan)

    1999-04-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  2. Tracking Quantum Jumps of Light with Repeated Single-Shot Parity Measurements

    Science.gov (United States)

    Sun, Luyan; Petrenko, Andrei; Leghtas, Zaki; Vlastakis, Brian; Kirchmair, Gerhard; Sliwa, Katrina; Narla, Anirudh; Hatridge, Michael; Shankar, Shyam; Blumoff, Jacob; Frunzio, Luigi; Mirrahimi, Mazyar; Devoret, Michel; Schoelkopf, Robert

    2014-03-01

    Quantum error correction (QEC) is required for a practical quantum computer because of the fragile nature of quantum information. A measurement-based QEC requires the measurement of error syndromes in a quantum non-demolition way and at a rate which is faster than errors occur. In a 3D circuit quantum electrodynamics architecture, we realize a parity measurement of a microwave field with about 90% fidelity by mapping its parity onto an ancilla qubit. The projective nature of the parity measurement onto a degenerate parity eigenspace, the cat states, is confirmed by Wigner tomography after a single parity measurement, showing 84% fidelity to ideal cats. The parity can therefore serve as an error syndrome for a recently proposed QEC scheme [Leghtas et.al. PRL (2013)]. We then demonstrate a tracking of quantum jumps of this error syndrome by repeated parity measurements. We will also discuss a quantum filter developed to mitigate the imperfections during the parity measurement for a best estimate of the photon state parity. The demonstrated extraction of error syndromes without perturbing the encoded information is essential for QEC. Current address: CQI, IIIS, Tsinghua University, Beijing, China.

  3. Gradient ROtating Outer Volume Excitation (GROOVE): A Novel Method for Single-Shot 2-D OVS

    Science.gov (United States)

    Powell, Nathaniel J.; Jang, Albert; Park, Jang-Yeon; Valette, Julien; Garwood, Michael; Marjańska, Małgorzata

    2014-01-01

    Purpose A new outer volume suppression (OVS) technique is introduced that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called Gradient ROtating Outer Volume Excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing the entire outer volume. Methods Theoretical and k-space descriptions of GROOVE are provided. The properties of GROOVE were investigated with simulations, phantom, and human experiments performed using a 4 T horizontal bore magnet equipped with a TEM coil. Results Similar suppression performance was obtained in phantom and human brain using GROOVE with circular and elliptical shapes. Simulations indicate that GROOVE requires less SAR and time than traditional OVS schemes, but traditional schemes provide a sharper transition zone and less residual signal. Conclusion GROOVE represents a new way of performing OVS in which spins are excited temporally in space on a trajectory which can be tailored to fit the shape of the suppression region. In addition, GROOVE is capable of suppressing tailored regions of space with more flexibility and in a shorter period of time than conventional methods. GROOVE provides a fast, low SAR alternative to conventional OVS methods in some applications (e.g., scalp suppression). PMID:24478130

  4. Rapid High-Fidelity Single-Shot Dispersive Readout of Superconducting Qubits

    Science.gov (United States)

    Walter, T.; Kurpiers, P.; Gasparinetti, S.; Magnard, P.; Potočnik, A.; Salathé, Y.; Pechal, M.; Mondal, M.; Oppliger, M.; Eichler, C.; Wallraff, A.

    2017-05-01

    The speed of quantum gates and measurements is a decisive factor for the overall fidelity of quantum protocols when performed on physical qubits with a finite coherence time. Reducing the time required to distinguish qubit states with high fidelity is, therefore, a critical goal in quantum-information science. The state-of-the-art readout of superconducting qubits is based on the dispersive interaction with a readout resonator. Here, we bring this technique to its current limit and demonstrate how the careful design of system parameters leads to fast and high-fidelity measurements without affecting qubit coherence. We achieve this result by increasing the dispersive-interaction strength, by choosing an optimal linewidth of the readout resonator, by employing a Purcell filter, and by utilizing phase-sensitive parametric amplification. In our experiment, we measure 98.25% readout fidelity in only 48 ns, when minimizing readout time, and 99.2% in 88 ns, when maximizing the fidelity, limited predominantly by the qubit lifetime of 7.6 μ s . The presented scheme is also expected to be suitable for integration into a multiplexed readout architecture.

  5. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  6. LITGS: a new technique for single shot temperature and fuel concentration measurements in turbulent combusting environments

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, Roberta; Giorgi, M. [ENEA, Centro Ricerche Frascati, Frascati, RM (Italy). Dipt. Innovazione; De Risi, A.; Laforgia, D. [Lecce Univ., Lecce (Italy). Dipt. di Ingegneria dell' Innovazione

    1999-07-01

    In the present study the possibility to apply time resolved Laser Induced Thermal Grating Spectroscopy (LITGS) to detect fuel concentration and temperature in mixtures and flames at atmospheric pressure or higher is investigated. The resonant IR single photon absorption of two short pulse pump beams is used to initially generate a population grating, decaying into a thermal grating due to relaxation processes in the gas mixture. The thermal grating evolution is followed by monitoring the scattered signal of a cw visible probe beam after the end of the pump pulse. The use of the IR optical transition of diesel fuel assured a high species selectivity and a negligible influence of the visible emission background due to the presence of electronically excited species in flames. Fuel concentration and temperature measurements in a pressurized cell, with pressure ranging between 0.1 an 1.5 MPa, and in a diffusion turbulent flame generated by a burner feed with diesel fuel operating at atmospheric pressure are presented. The experimental investigation shows that LITGS signal increase linearly with gas density. This characteristic makes LITGS a very interesting technique for fuel distribution and temperature measurements in hostile (high-pressure and turbulent flow) environments. Detection limit for diesel fuel at atmospheric pressure is found to be about 40 ppm and it decreases with the increase of the pressure. The low detection limit which can be reached makes this technique suitable also for monitoring minor species and radicals. [Italian] Nel presente studio si investiga la possibilita' di applicare la tecnica LITGS (Laser Induced Thermal Grating Spectroscopy) per misurare la concentrazione e la temperatura di carburante in miscele e fiamme a pressiona atmosferica o superiore. L'assorbimento risonante di un singolo fotone IR proveniente da uno dei due laser impulsati di pompa e' utilizzato per generare inizialmente un reticolo di popolazione, che decade

  7. Non-contrast-enhanced imaging of haemodialysis fistulas using quiescent-interval single-shot (QISS) MRA: a feasibility study

    International Nuclear Information System (INIS)

    Okur, A.; Kantarci, M.; Karaca, L.; Yildiz, S.; Sade, R.; Pirimoglu, B.; Keles, M.; Avci, A.; Çankaya, E.; Schmitt, P.

    2016-01-01

    Aim: To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. Materials and methods: QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. Results: One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. Conclusion: QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. - Highlights: • Close monitoring and early intervention in hemodialysis fistulas may prolong longevity fistulas. • DopplerUS, contrast enhanced CT and MRI are using assessment of hemodialysis fistulas. • QISS nonenhanced MR angiography represents an alternative for assessment of hemodialysis fistulas.

  8. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  9. Feasibility study of a single-shot 3D electron bunch shape monitor with an electro-optic sampling technique

    Directory of Open Access Journals (Sweden)

    Yuichi Okayasu

    2013-05-01

    Full Text Available We developed a three-dimensional electron bunch charge distribution (3D-BCD monitor with single-shot detection, and a spectral decoding based electro-optic (EO sampling technique for a nondestructive monitor enables real-time reconstruction of the three-dimensional distribution of a bunch charge. We realized three goals by simultaneously probing a number of Pockels EO crystals that surround the electron beam axis with hollow and radial polarized laser pulses. First, we performed a feasibility test as a simple case of a 3D-BCD monitor probing two ZnTe crystals as EO detectors installed on the opposite angle to the electron beam axis and confirmed that we simultaneously obtained both EO signals. Since the adopted hollow probe laser pulse is not only radially polarized but also temporally shifted azimuthally, some disorders in the radial polarization distribution of such a laser pulse were numerically analyzed with a plane-wave expansion method. Based on the above investigations, the 3D-BCD monitor is feasible both in experimental and numerical estimations. Furthermore, we previously developed a femtosecond response organic crystal as a Pockels EO detector and a broadband probe laser (≥350  nm in FWHM; the 3D-BCD monitor realizes 30- to 40-fs (FWHM temporal resolution. Eventually, the monitor is expected to be equipped in such advanced accelerators as XFEL to measure and adjust the electron bunch charge distribution in real time. The 3D-BCD measurement works as a critical tool to provide feedback to seeded FELs.

  10. Wavefront Analysis of Nonlinear Self-Amplified Spontaneous-Emission Free-Electron Laser Harmonics in the Single-Shot Regime

    Energy Technology Data Exchange (ETDEWEB)

    Bachelard, R.; Chubar, O.; Mercere, P.; Idir, M.; Couprie, M.E.; Lambert, G.; Zeitoun, Ph.; Kimura, H.; Ohashi, H.; Higashiya, A.; Yabashi, M.; Nagasono, M.; Hara, T. and Ishikawa, T.

    2011-06-08

    The single-shot spatial characteristics of the vacuum ultraviolet self-amplified spontaneous emission of a free electron laser (FEL) is measured at different stages of amplification up to saturation with a Hartmann wavefront sensor. We show that the fundamental radiation at 61.5 nm tends towards a single-mode behavior as getting closer to saturation. The measurements are found in good agreement with simulations and theory. A near diffraction limited wavefront was measured. The analysis of Fresnel diffraction through the Hartmann wavefront sensor hole array also provides some further insight for the evaluation of the FEL transverse coherence, of high importance for various applications.

  11. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences.

    Science.gov (United States)

    Ruangwattanapaisarn, Nichanan; Loening, Andreas M; Saranathan, Manojkumar; Litwiller, Daniel V; Vasanawala, Shreyas S

    2015-06-01

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity.

  12. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    International Nuclear Information System (INIS)

    Ruangwattanapaisarn, Nichanan; Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S.; Litwiller, Daniel V.

    2015-01-01

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  13. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S. [Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Litwiller, Daniel V. [GE Healthcare, Rochester, MN (United States)

    2015-06-15

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  14. Infrared-spectroscopic single-shot laser mapping ellipsometry: Proof of concept for fast investigations of structured surfaces and interactions in organic thin films

    Science.gov (United States)

    Furchner, Andreas; Kratz, Christoph; Gkogkou, Dimitra; Ketelsen, Helge; Hinrichs, Karsten

    2017-11-01

    We present a novel infrared-spectroscopic laser mapping ellipsometer based on a single-shot measurement concept. The ellipsometric set-up employs multiple analyzers and detectors to simultaneously measure the sample's optical response under different analyzer azimuths. An essential component is a broadly tunable quantum cascade laser (QCL) covering the important marker region of 1800-1540 cm-1. The ellipsometer allows for fast single-wavelength as well as spectroscopic studies with thin-film sensitivity at temporal resolutions of 60 ms per wavelength. We applied the single-shot mapping ellipsometer for the characterization of metal-island enhancement surfaces as well as of molecular interactions in organic thin films. In less than 3 min, a linescan with 1600 steps revealed profile and infrared-enhancement properties of a gradient gold-island film for sensing applications. Spectroscopic measurements were performed to probe the amide I band of thin films of poly(N-isopropylacrylamide) [PNIPAAm], a stimuli-responsive polymer for bioapplications. The QCL spectra agree well with conventional FT-IR ellipsometric results, showing different band components associated with hydrogen-bond interactions between polymer and adsorbed water. Multi-wavelength ellipsometric maps were used to analyze homogeneity and surface contaminations of the polymer films.

  15. 1D-transport properties of single superconducting lead nanowires

    DEFF Research Database (Denmark)

    Michotte, S.; Mátéfi-Tempfli, Stefan; Piraux, L.

    2003-01-01

    We report on the transport properties of single superconducting lead nanowires grown by an electrodeposition technique, embedded in a nanoporous track-etched polymer membrane. The nanowires are granular, have uniform diameter of ̃40 nm and a very large aspect ratio (̃500). The diameter of the nan......We report on the transport properties of single superconducting lead nanowires grown by an electrodeposition technique, embedded in a nanoporous track-etched polymer membrane. The nanowires are granular, have uniform diameter of ̃40 nm and a very large aspect ratio (̃500). The diameter...

  16. The "curved lead pathway" method to enable a single lead to reach any two intracranial targets.

    Science.gov (United States)

    Ding, Chen-Yu; Yu, Liang-Hong; Lin, Yuan-Xiang; Chen, Fan; Lin, Zhang-Ya; Kang, De-Zhi

    2017-01-11

    Deep brain stimulation is an effective way to treat movement disorders, and a powerful research tool for exploring brain functions. This report proposes a "curved lead pathway" method for lead implantation, such that a single lead can reach in sequence to any two intracranial targets. A new type of stereotaxic system for implanting a curved lead to the brain of human/primates was designed, the auxiliary device needed for this method to be used in rat/mouse was fabricated and verified in rat, and the Excel algorithm used for automatically calculating the necessary parameters was implemented. This "curved lead pathway" method of lead implantation may complement the current method, make lead implantation for multiple targets more convenient, and expand the experimental techniques of brain function research.

  17. Angle-resolved spectral Fabry-Pérot interferometer for single-shot measurement of refractive index dispersion over a broadband spectrum

    Science.gov (United States)

    Dong, J. T.; Ji, F.; Xia, H. J.; Liu, Z. J.; Zhang, T. D.; Yang, L.

    2018-01-01

    An angle-resolved spectral Fabry-Pérot interferometer is reported for fast and accurate measurement of the refractive index dispersion of optical materials with parallel plate shape. The light sheet from the wavelength tunable laser is incident on the parallel plate with converging angles. The transmitted interference light for each angle is dispersed and captured by a 2D sensor, in which the rows and the columns are used to simultaneously record the intensities as a function of wavelength and incident angle, respectively. The interferogram, named angle-resolved spectral intensity distribution, is analyzed by fitting the phase information instead of finding the fringe peak locations that present periodic ambiguity. The refractive index dispersion and the physical thickness can be then retrieved from a single-shot interferogram within 18 s. Experimental results of an optical substrate standard indicate that the accuracy of the refractive index dispersion is less than 2.5  ×  10-5 and the relative uncertainty of the thickness is 6  ×  10-5 mm (3σ) due to the high stability and the single-shot measurement of the proposed system.

  18. Diffusion-weighted MRI of the cervical spinal cord using a single-shot fast spin-echo technique: findings in normal subjects and in myelomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, K.; Katase, S.; Fujikawa, A.; Hachiya, J. [Department of Radiology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, 181-8611, Tokyo (Japan); Kanazawa, H. [Toshiba Corporation, 1-1-1 Shibaura, Minato-ku, 105-8001, Tokyo (Japan); Yodo, K. [Toshiba Medical Systems, 3-26-5 Hongo, Bunkyo-ku, 113-8456, Tokyo (Japan)

    2003-02-01

    We have implemented a new diffusion-weighted MRI (DWI) sequence based on the single-shot fast spin-echo technique. We hypothesised that this would add information to conventional MRI for diagnosis of lesions of the cervical spinal cord. DWI was performed using a technique in which echo collection after the application of motion-probing gradients was done in the same manner as in the single-shot fast spin-echo technique. We first imaged six healthy volunteers to demonstrate the cervical spinal cord using the sequence. Then we applied the sequence to 12 patients with cervical myelomalacia due to chronic cord compression. The spinal cord was well seen in all subjects without the distortion associated with echo-planar DWI. In the patients, lesions appeared as areas of low- or isointense signal on DWI. Calculated apparent diffusion coefficients of the lesions (3.30{+-}0.38 x 10{sup -3} mm{sup 2}/s) were significantly higher than those of normal volunteers (2.26{+-}0.08 x 10{sup -3} mm{sup 2}/s). Increased diffusion in areas of cervical myelomalacia, suggesting irreversible damage, can be detected using this technique. (orig.)

  19. A single-shot T2mapping protocol based on echo-split gradient-spin-echo acquisition and parametric multiplexed sensitivity encoding based on projection onto convex sets reconstruction.

    Science.gov (United States)

    Chu, Mei-Lan; Chang, Hing-Chiu; Oshio, Koichi; Chen, Nan-Kuei

    2018-01-01

    To develop a high-speed T 2 mapping protocol that is capable of accurately measuring T 2 relaxation time constants from a single-shot acquisition. A new echo-split single-shot gradient-spin-echo (GRASE) pulse sequence is developed to acquire multicontrast data while suppressing signals from most nonprimary echo pathways in Carr-Purcell-Meiboom-Gill (CPMG) echoes. Residual nonprimary pathway signals are taken into consideration when performing T 2 mapping using a parametric multiplexed sensitivity encoding based on projection onto convex sets (parametric-POCSMUSE) reconstruction method that incorporates extended phase graph modeling of GRASE signals. The single-shot echo-split GRASE-based T 2 mapping procedure was evaluated in human studies at 3 Tesla. The acquired data were compared with reference data obtained with a more time-consuming interleaved spin-echo echo planar imaging protocol. T 2 maps derived from conventional single-shot GRASE scans, in which nonprimary echo pathways were not appropriately addressed, were also evaluated. Using the developed single-shot T 2 mapping protocol, quantitatively accurate T 2 maps can be obtained with a short scan time (parametric-POCSMUSE reconstruction. Magn Reson Med 79:383-393, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  20. Small Field-of-view single-shot EPI-DWI of the prostate: Evaluation of spatially-tailored two-dimensional radiofrequency excitation pulses.

    Science.gov (United States)

    Attenberger, Ulrike I; Rathmann, Nils; Sertdemir, Metin; Riffel, Philipp; Weidner, Anja; Kannengiesser, Stefan; Morelli, John N; Schoenberg, Stefan O; Hausmann, Daniel

    2016-06-01

    Spatially-tailored (RF) excitation pulses in echo-planar imaging (EPI), combined with a decreased FOV in the phase-encoding direction, enable a reduction of k-space acquisition lines, which shortens the echo train length (ETL) and reduces susceptibility artifacts. The purpose of this study was to evaluate the image quality of a zoomed EPI (z-EPI) sequence in diffusion-weighted imaging (DWI) of the prostate in comparison to a conventional single-shot EPI using single-channel (c-EPI1) and multi-channel (c-EPI2) RF excitation, with and without use of an endorectal coil. 33 consecutive patients (mean age: 61 +/- 9 years; mean PSA: 8.67±6.23 ng/ml) with examinations between 10/2012 and 02/2014 were analyzed in this retrospective study. In 26 of 33 patients the initial multiparametric (mp)-MRI was performed on a whole-body 3T scanner (Magnetom Trio, Siemens, Erlangen, Germany) using an endorectal coil (c (conventional)-EPI1). Zoomed-EPI (Z-EPI) examinations of these patients and a complete mp-MRI protocol including c-EPI2 of 7 additional patients were carried out on another 3T wb MR scanner with two-channel dynamic parallel transmit capability (Magnetom Skyra with TimTX TrueShape, Siemens). For z-EPI, the one-dimensional spatially selective RF excitation pulse was replaced by a two-dimensional RF pulse. Degree of image blur and susceptibility artifacts (0=not present to 3= non-diagnostic), maximum image distortion (mm), apparent diffusion coefficient (ADC) values, as well as overall scan preference were evaluated. SNR maps were generated to compare c-EPI2 and z-EPI. Overall image quality of z-EPI was preferred by both readers in all examinations with a single exception. Susceptibility artifacts were rated significantly lower on z-EPI compared to both other methods (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01) as well as image blur (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01). Image distortion was not statistically significantly reduced with z-EPI (z-EPI vs c

  1. Highly Resolved Mg/Ca Depth Profiles of Planktic Foraminifer test Walls Using Single shot Measurements of fs-LA-ICPMS

    Science.gov (United States)

    Jochum, K. P.; Schiebel, R.; Stoll, B.; Weis, U.; Haug, G. H.

    2017-12-01

    Foraminifers are sensitive archives of changes in climate and marine environment. It has been shown that the Mg/Ca signal is a suitable proxy of seawater temperature, because the incorporation of Mg depends on ambient water temperature. In contrast to most former studies, where this ratio is determined by solution-based bulk analysis of 20 - 30 specimens, we have investigated Mg/Ca in single specimens and single chambers at high resolution. A new fs-200 nm-LA-ICPMS technique was developed for the µm-sized layered calcite shells. To generate depth profiles with a resolution of about 50 nm/shot, we chose a low fluence of about 0.3 Jcm-2 and performed single shot measurements of the double charged 44Ca++ and the single charged 25Mg+ ions together. Precision (RSD) of the Mg/Ca data is about 5 %. Calibration was performed with the carbonate reference material MACS-3 from the USGS. Our results for different species from the Arabian Sea and Caribbean Sea demonstrate that Mg/Ca of different chambers vary and indicate that the foraminifer individuals built their chambers in different water depths and/or experienced seasonal changes in seawater temperature caused, for example, by upwelling (cold) versus stratified (warm) conditions. Typically, the Mg/Ca ratios of the final two chambers of the planktic foraminifer Globorotalia menardii from a sediment core of the Arabian Sea differ by about 5 mmol/mol from earlier chambers (2 mmol/mol) corresponding to seawater temperatures of 28 °C and 18 °C, respectively. In addition, mass fractions of other elements like Sr, Mn, Fe, Ba, and U have been determined with fs-LA-ICPMS using fast line scans, and thus provide further insights in the ecology of foraminifers.

  2. Shot Automation for the National Ignition Facility

    International Nuclear Information System (INIS)

    Lagin, L J; Bettenhausen, R C; Beeler, R G; Bowers, G A; Carey, R.; Casavant, D.D.; Cline, B.D.; Demaret, R.D.; Domyancic, D.M.; Elko, S.D.; Fisher, J.M.; Hermann, M.R.; Krammen, J.E.; Kohut, T.R.; Marshall, C.D.; Mathisen, D.G.; Ludwigsen, A.P.; Patterson, Jr. R.W.; Sanchez, R.J.; Stout, E.A.; Van Arsdall, P.J.; Van Wonterghem, B.M.

    2005-01-01

    A shot automation framework has been developed and deployed during the past year to automate shots performed on the National Ignition Facility (NIF) using the Integrated Computer Control System This framework automates a 4-8 hour shot sequence, that includes inputting shot goals from a physics model, set up of the laser and diagnostics, automatic alignment of laser beams and verification of status. This sequence consists of set of preparatory verification shots, leading to amplified system shots using a 4-minute countdown, triggering during the last 2 seconds using a high-precision timing system, followed by post-shot analysis and archiving. The framework provides for a flexible, model-based execution driven of scriptable automation called macro steps. The framework is driven by high-level shot director software that provides a restricted set of shot life cycle state transitions to 25 collaboration supervisors that automate 8-laser beams (bundles) and a common set of shared resources. Each collaboration supervisor commands approximately 10 subsystem shot supervisors that perform automated control and status verification. Collaboration supervisors translate shot life cycle state commands from the shot director into sequences of ''macro steps'' to be distributed to each of its shot supervisors. Each Shot supervisor maintains order of macro steps for each subsystem and supports collaboration between macro steps. They also manage failure, restarts and rejoining into the shot cycle (if necessary) and manage auto/manual macro step execution and collaborations between other collaboration supervisors. Shot supervisors execute macro step shot functions commanded by collaboration supervisors. Each macro step has database-driven verification phases and a scripted perform phase. This provides for a highly flexible methodology for performing a variety of NIF shot types. Database tables define the order of work and dependencies (workflow) of macro steps to be performed for a

  3. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy.

    Science.gov (United States)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori; Fujioka, Shinsuke; Azechi, Hiroshi

    2016-04-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10(13) photons/shot) hard X-rays. However, high energy resolution (Δhv/hv spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  4. Quantitative analysis of the breath-holding half-Fourier acquisition single-shot turbo spin-echo technique in abdominal MRI

    Science.gov (United States)

    Dong, Kyung-Rae; Goo, Eun-Hoe; Lee, Jae-Seung; Chung, Woon-Kwan

    2013-01-01

    A consecutive series of 50 patients (28 males and 22 females) who underwent hepatic magnetic resonance imaging (MRI) from August to December 2011 were enrolled in this study. The appropriate parameters for abdominal MRI scans were determined by comparing the images (TE = 90 and 128 msec) produced using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) technique at different signal acquisition times. The patients consisted of 15 normal patients, 25 patients with a hepatoma and 10 patients with a hemangioma. The TE in a single patient was set to either 90 msec or 128 msec. This was followed by measurements using the four normal rendering methods of the biliary tract system and the background signal intensity using the maximal signal intensity techniques in the liver, spleen, pancreas, gallbladder, fat, muscles and hemangioma. The signal-to-noise and the contrast-to-noise ratios were obtained. The image quality was assessed subjectively, and the results were compared. The signal-to-noise and the contrast-to-noise ratios were significantly higher at TE = 128 msec than at TE = 90 when diseases of the liver, spleen, pancreas, gallbladder, and fat and muscles, hepatocellular carcinomas and hemangiomas, and rendering the hepatobiliary tract system based on the maximum signal intensity technique were involved (p breath-hold half-Fourier acquisition single-shot turbo spin-echo (HASTE) was found to be effective in illustrating the abdominal organs for TE = 128 msec. Overall, the image quality at TE = 128 msec was better than that at TE = 90 msec due to the improved signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Overall, the HASTE technique for abdominal MRI based on a high-magnetic field (3.0 T) at a TE of 128 msec can provide useful data.

  5. Single-shot characterization of enzymatic reaction constants Km and kcat by an acoustic-driven, bubble-based fast micromixer

    Science.gov (United States)

    Xie, Yuliang; Ahmed, Daniel; Lapsley, Michael Ian; Lin, Sz-Chin Steven; Nawaz, Ahmad Ahsan; Wang, Lin; Huang, Tony Jun

    2014-01-01

    In this work we present an acoustofluidic approach for rapid, single-shot characterization of enzymatic reaction constants Km and kcat. The acoustofluidic design involves a bubble anchored in a horseshoe structure which can be stimulated by a piezoelectric transducer to generate vortices in the fluid. The enzyme and substrate can thus be mixed rapidly, within 100 ms, by the vortices to yield the product. Enzymatic reaction constants Km and kcat can then be obtained from the reaction rate curves for different concentrations of substrate while holding the enzyme concentration constant. We studied the enzymatic reaction for β-galactosidase and its substrate (resorufin β-D-galactopyranoside) and found Km and kcat to be 333±130 =M and 64±8 s−1 respectively, which are in agreement with published data. Our approach is valuable for studying the kinetics of high-speed enzymatic reactions and other chemical reactions. PMID:22880882

  6. Measurement of the X-ray Spectrum of a Free Electron Laser with a Wide-Range High-Resolution Single-Shot Spectrometer

    Directory of Open Access Journals (Sweden)

    Yuichi Inubushi

    2017-06-01

    Full Text Available We developed a single-shot X-ray spectrometer for wide-range high-resolution measurements of Self-Amplified Spontaneous Emission (SASE X-ray Free Electron Laser (XFEL pulses. The spectrometer consists of a multi-layer elliptical mirror for producing a large divergence of 22 mrad around 9070 eV and a silicon (553 analyzer crystal. We achieved a wide energy range of 55 eV with a fine spectral resolution of 80 meV, which enabled the observation of a whole SASE-XFEL spectrum with fully-resolved spike structures. We found that a SASE-XFEL pulse has around 60 longitudinal modes with a pulse duration of 7.7 ± 1.1 fs.

  7. Clinical single-shot diffusion-weighted MRI of the human brain on a short-bore medium-field imager

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Remonda, L.; Schneider, J.; Goenner, F.; Schroth, G.; Heid, O.

    1999-01-01

    Diffusion-weighted MRI (DWI) is becoming important for assessment of acute stroke. Until recently single-shot DWI required expensive technology such as echo-planar imaging (EPI) available only at some research sites. A new medium-field (1.0 T) short-bore MR imager has been developed with which DWI data sets can be acquired. We prospectively studied 169 patients on this 1.0 T commercial system. After conventional imaging, DWI was performed with a single-shot multi-slice sequence with b values 0 an 900 s/mm 2 , and with the gradients switched in three directions. The apparent diffusion coefficients were calculated with online calculation software. There were 50 patients with totally normal MRI, and 17 had strokes, these strokes were detected as areas of high signal on the images at a maximal b value. There was a drop in the ADC in ischaemic regions: in subacute infarcts, the values were between 0.41 and 0.531 x 10 - 3 mm 2 /s. In old infarcts the ADC was 1.15 x 10 - 3 mm 2 /s. Cerebrospinal fluid (CSF) gave low signal whereas areas in the brain had more intermediate intensities (CSF: 3.00; deep white matter: 0.75, cortical grey matter: 0.80, basal ganglia (thalamus): 0.70 and cerebellar white matter: 0.65 x 10 - 3 mm 2 /s). Anisotropy was detected as areas of restricted diffusion along the tracts. These preliminary data show that DWI can be aquired successfully on a medium-field short-bore system. This should allow the technique to be implemented at more sites, therefore facilitating the diagnosis of acute stroke and rendering early intervention feasible. (orig.)

  8. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy

    International Nuclear Information System (INIS)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke; Azechi, Hiroshi; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori

    2016-01-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10 13 photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO 2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  9. Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging

    NARCIS (Netherlands)

    Coenegrachts, Kenneth; Matos, Celso; ter Beek, Léon; Metens, Thierry; Haspeslagh, Marc; Bipat, Shandra; Stoker, Jaap; Rigauts, Hans

    2009-01-01

    Purpose: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5 min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). Materials and

  10. Allergy Shots (For Parents)

    Science.gov (United States)

    ... animal dander. Allergy shots are not useful for food allergies. When receiving allergy shots, a child may experience ... Allergies First Aid: Allergic Reactions Insect Sting Allergy Food Allergies Serious Allergic Reactions (Anaphylaxis) Word! Allergy Word! Allergy ...

  11. Birth Control Shot

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Birth Control Shot KidsHealth / For Teens / Birth Control Shot What's in this article? What Is ... español La inyección anticonceptiva What Is It? The birth control shot is a long-acting form of ...

  12. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

    Science.gov (United States)

    Zhang, Zhenbin; Dovichi, Norman J

    2018-02-25

    The effects of MS1 injection time, MS2 injection time, dynamic exclusion time, intensity threshold, and isolation width were investigated on the numbers of peptide and protein identifications for single-shot bottom-up proteomics analysis using CZE-MS/MS analysis of a Xenopus laevis tryptic digest. An electrokinetically pumped nanospray interface was used to couple a linear-polyacrylamide coated capillary to a Q Exactive HF mass spectrometer. A sensitive method that used a 1.4 Th isolation width, 60,000 MS2 resolution, 110 ms MS2 injection time, and a top 7 fragmentation produced the largest number of identifications when the CZE loading amount was less than 100 ng. A programmable autogain control method (pAGC) that used a 1.4 Th isolation width, 15,000 MS2 resolution, 110 ms MS2 injection time, and top 10 fragmentation produced the largest number of identifications for CZE loading amounts greater than 100 ng; 7218 unique peptides and 1653 protein groups were identified from 200 ng by using the pAGC method. The effect of mass spectrometer conditions on the performance of UPLC-MS/MS was also investigated. A fast method that used a 1.4 Th isolation width, 30,000 MS2 resolution, 45 ms MS2 injection time, and top 12 fragmentation produced the largest number of identifications for 200 ng UPLC loading amount (6025 unique peptides and 1501 protein groups). This is the first report where the identification number for CZE surpasses that of the UPLC at the 200 ng loading level. However, more peptides (11476) and protein groups (2378) were identified by using UPLC-MS/MS when the sample loading amount was increased to 2 μg with the fast method. To exploit the fast scan speed of the Q-Exactive HF mass spectrometer, higher sample loading amounts are required for single-shot bottom-up proteomics analysis using CZE-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. [In-phase and out-of-phase single-shot magnetization-prepared gradient recalled echo: description and optimization of technique at 1.5 T].

    Science.gov (United States)

    Ramalho, M; Herédia, V; de Campos, R O P; de Toni, M; Dale, B M; Semelka, R C

    2014-01-01

    To implement in-phase and out-of-phase (IP/OP) techniques with Magnetization-Prepared Gradient Recalled Echo (MP-GRE) and to evaluate the feasibility and diagnostic image quality among pre and post-optimized MP-GRE sequences, including patients unable to cooperate with breath-hold requirements. Institutional review board approval with waiver of informed consent was obtained for this HIPAA-compliant retrospective study. Two groups of patients were included in the study, before and after optimization of MP-GRE parameters, with seventy-three (24 noncooperative/49 cooperative) and sixty-four (22 noncooperative/42 cooperative) consecutive patients, respectively. The motion-insensitive sequence used in this study was a single-shot 2D MP-GRE. Two radiologists qualitatively evaluated the sequences to identify the presence of phase cancellation artifact in OP images and to determine image quality, extent of artifacts (respiratory ghosting, bounce-point artifact, spatial misregistration and pixel graininess) and lesion conspicuity on the various sequences. The ability to visually detect liver steatosis and fatty adrenal adenomas was evaluated. Qualitative analyses were compared using the Wilcoxon and Mann-Whitney tests. There were statistically significant differences between all MP-GRE sequences concerning phase cancellation artifact (P<.0001) which was present in MP-GRE OP sequences and negligible to absent in the pre (IP1) and post-optimized (IP2) MP-GRE IP sequences, respectively, in all patients. Bounce point artifacts were significantly more pronounced in MP-GRE IP1 (P<.0001). Spatial misregistration was slightly more prominent in noncooperative patients with MP-GRE IP2 (P=.0027). MP-GRE OP and MP-GRE IP2 showed significantly higher overall image quality (P<.0001). MP-GRE sequences subjectively identified hepatic steatosis (n=20) and adrenal adenomas (n=5) based on signal loss from IP to OP sequence. Single shot IP/OP MP-GRE is feasible and allows motion resistant

  14. Single shot spinal anesthesia with very low hyperbaric bupivacaine dose (3.75 mg) for hip fracture repair surgery in the elderly. A randomized, double blinded study.

    Science.gov (United States)

    Errando, C L; Peiró, C M; Gimeno, A; Soriano, J L

    2014-11-01

    Single shot spinal anesthesia is used worldwide for hip fracture repair surgery in the elderly. Arterial hypotension is a frequent adverse effect. We hypothesized that lowering local anesthetics dose could decrease the incidence of arterial hypotension, while maintaining quality of surgical anesthesia. In a randomized double blinded study, 66 patients over the age of 65 years, with hip fracture needing surgical repair, were assigned to B0.5 group 7.5mg hyperbaric bupivacaine 5mg/ml (control group), and B0.25 group 3.75mg hyperbaric bupivacaine 2.5mg/ml (study group). Sensory and motor block level, and hemodynamic parameters including blood presure, heart rate and vasopressor dose administration were registered, along with rescue anesthesia needs, the feasibility of surgery, its duration, and regression time of sensory anesthesia to T12. After exclusions, 61 patients were included in the final analysis. Arterial hypotension incidence was lower in the B0.25 group (at the 5, 10, and 15min determinations), and a lower amount of vasopressor drugs was needed (mean accumulated ephedrine dose 1.6mg vs. 8.7mg in the B0.5 group, p<0.002). Sensory block regression time to T12 was shorter in the B0.25 group, mean 78.6±23.6 (95% CI 51.7-110.2)min vs. 125.5±37.9 (95% CI 101.7-169.4)min in the B0.5 group, p=0.033. All but one patient in the B0.25 group were operated on under the anesthetic procedure first intended. No rescue anesthesia was needed. Lowering bupivacaine dose for single shot spinal anesthesia for hip fracture repair surgery in elderly patients was effective in decreasing the occurrence of arterial hypotension and vasopressor use, while intraoperative quality remained. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Treating Acute Insomnia: A Randomized Controlled Trial of a "Single-Shot" of Cognitive Behavioral Therapy for Insomnia.

    Science.gov (United States)

    Ellis, Jason G; Cushing, Toby; Germain, Anne

    2015-06-01

    Despite considerable evidence supporting cognitive behavioral therapy for insomnia (CBT-I) for chronic insomnia, it remains untested within the context of acute insomnia. This study examined the efficacy of a single session of CBT-I, with an accompanying self-help pamphlet, for individuals with acute insomnia. A pragmatic parallel group randomized controlled trial. Community. Forty adults (mean age 32.9 ± 13.72 y) with Diagnostic and Statistical Manual of Mental Disorders, Fifth Edition (DSM-5) defined insomnia disorder, except a self-reported duration of less than 3 mo (i.e., acute insomnia), who reported no previous exposure to CBT-I and were not currently taking medication for sleep. A single 60- to 70-min session of CBT-I (n = 20), with an accompanying self-help pamphlet, or wait list control group (n = 20). All subjects were offered a full individual course of CBT-I on completion of the study, regardless of group allocation. Subjects completed sleep diaries and the Insomnia Severity Index (ISI) pretreatment and 1 mo following treatment. There were no between-group differences on baseline ISI scores or subjective sleep continuity. The intervention group reported significantly lower ISI scores than controls (t(38) 2.24, P insomnia caseness (i.e., ≥ 10), 60% of those in the CBT-I group had remitted by 1 mo compared to 15% of those in the control group. This single session of cognitive behavioral therapy for insomnia (CBT-I) is sufficiently efficacious for a significant proportion of those with acute insomnia. The results are discussed in terms of integrating this brief form of CBT-I into the "stepped care" model of insomnia. Testing the efficacy of an early intervention for acute insomnia (SRCTN05891695) http://www.controlled-trials.com/ISRCTN05891695. © 2015 Associated Professional Sleep Societies, LLC.

  16. Integration of an Optical Ring Resonator Biosensor into a Self-Contained Microfluidic Cartridge with Active, Single-Shot Micropumps

    Directory of Open Access Journals (Sweden)

    Sascha Geidel

    2016-09-01

    Full Text Available While there have been huge advances in the field of biosensors during the last decade, their integration into a microfluidic environment avoiding external tubing and pumping is still neglected. Herein, we show a new microfluidic design that integrates multiple reservoirs for reagent storage and single-use electrochemical pumps for time-controlled delivery of the liquids. The cartridge has been tested and validated with a silicon nitride-based photonic biosensor incorporating multiple optical ring resonators as sensing elements and an immunoassay as a potential target application. Based on experimental results obtained with a demonstration model, subcomponents were designed and existing protocols were adapted. The newly-designed microfluidic cartridges and photonic sensors were separately characterized on a technical basis and performed well. Afterwards, the sensor was functionalized for a protein detection. The microfluidic cartridge was loaded with the necessary assay reagents. The integrated pumps were programmed to drive the single process steps of an immunoassay. The prototype worked selectively, but only with a low sensitivity. Further work must be carried out to optimize biofunctionalization of the optical ring resonators and to have a more suitable flow velocity progression to enhance the system’s reproducibility.

  17. Pin-hole array production and detailed data analysis for advanced single-shot X-ray imaging of laboratory plasmas

    Science.gov (United States)

    Levato, T.; Labate, L.; Pathak, N. C.; Cecchetti, C.; Koester, P.; Di Fabrizio, E.; Delogu, P.; Giulietti, A.; Giulietti, D.; Gizzi, L. A.

    2010-11-01

    Laser produced plasmas offer the unique opportunity to investigate physical mechanisms working at extremely high field in pulsed regime [1] (Gizzi et al., 2009). Future large scale infrastructure like HiPER and ELI may open new frontiers of knowledge in this way. Technologies needed for improving diagnostic in this field have a strong impact on a wide range of multi-disciplinary applications as for compact plasma-based accelerators [1,2] (Gizzi et al., 2009; Betti et al., 2009) laser fusion oriented experiments, three-dimensional microscopy and lithography. As an example the X-ray imaging, being a powerful diagnostic tool for deep investigation on different variety of laser produced plasma, has obtained a grooving effort in recent years. Large scale facilities working in single-pulse regime for laser fusion oriented experiments have evidenced the necessity to obtain spectrally resolved X-ray images of produced plasmas in a single shot. By combining the charge coupled devices (CCD) based single-photon detection technique with a pin-hole array (PHA) a new diagnostic technique was developed, as shown in recent experiments related to the European HiPER project [3] (Labate et al., 2009). Here we qualitatively describe the PHA production process on a heavy metal substrate by means of SEM images that show an internal diameter on the micrometer scale and an aspect ratio of about 20. The characterization of the X-ray contrast up to 90 keV is presented. The data analysis of the X-ray photons interaction on CCD, for spectrum reconstruction up to high energy, is described [4] (Levato et al., 2008).

  18. Pin-hole array production and detailed data analysis for advanced single-shot X-ray imaging of laboratory plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Levato, T., E-mail: tadzio.levato@lnf.infn.i [FLAME, Laboratori Nazionali di Frascati (LNF), Via E. Fermi 40, 00044 Frascati (Italy); Labate, L.; Pathak, N.C.; Cecchetti, C.; Koester, P. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy); Di Fabrizio, E. [BIONEM, Campus Magna Graecia University of Catanzaro (UMG) (Italy); Delogu, P. [University of Pisa, Department of Physics (Italy); Giulietti, A. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy); Giulietti, D. [University of Pisa, Department of Physics (Italy); Gizzi, L.A. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy)

    2010-11-11

    Laser produced plasmas offer the unique opportunity to investigate physical mechanisms working at extremely high field in pulsed regime (Gizzi et al., 2009). Future large scale infrastructure like HiPER and ELI may open new frontiers of knowledge in this way. Technologies needed for improving diagnostic in this field have a strong impact on a wide range of multi-disciplinary applications as for compact plasma-based accelerators (Gizzi et al., 2009; Betti et al., 2009) laser fusion oriented experiments, three-dimensional microscopy and lithography. As an example the X-ray imaging, being a powerful diagnostic tool for deep investigation on different variety of laser produced plasma, has obtained a grooving effort in recent years. Large scale facilities working in single-pulse regime for laser fusion oriented experiments have evidenced the necessity to obtain spectrally resolved X-ray images of produced plasmas in a single shot. By combining the charge coupled devices (CCD) based single-photon detection technique with a pin-hole array (PHA) a new diagnostic technique was developed, as shown in recent experiments related to the European HiPER project (Labate et al., 2009). Here we qualitatively describe the PHA production process on a heavy metal substrate by means of SEM images that show an internal diameter on the micrometer scale and an aspect ratio of about 20. The characterization of the X-ray contrast up to 90 keV is presented. The data analysis of the X-ray photons interaction on CCD, for spectrum reconstruction up to high energy, is described (Levato et al., 2008).

  19. Low-field single-sided NMR for one-shot 1D-mapping: Application to membranes

    Science.gov (United States)

    Judeinstein, Patrick; Ferdeghini, Filippo; Oliveira-Silva, Rodrigo; Zanotti, Jean-Marc; Sakellariou, Dimitrios

    2017-04-01

    Many single-sided permanent magnet NMR systems have been proposed over the years allowing for 1D proton-density profiling, diffusion measurements and relaxometry. In this manuscript we make use of a recently published unilateral magnet for low-field NMR exhibiting an extremely uniform magnetic field gradient with moderate strength and cylindrical symmetry, allowing for a well-defined sweet spot. Combined with a goniometer, our system is used to characterize precisely the uniformity of its gradient and to achieve micrometric precision 1D profiling, as well as spatially localized relaxometry and diffusometry on thick (∼150 μm) membrane samples. Profiling with this magnet did not require repositioning of the samples with respect to the 1D tomograph.

  20. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Blondin, D., E-mail: blondin@med.uni-duesseldorf.de [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Schmitt, P. [Siemens AG, Healthcare Sector, Erlangen (Germany); Bi, X. [Siemens Healthcare, Chicago, IL (United States); Sansone, R. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Wittsack, H.-J.; Kroepil, P.; Quentin, M.; Kuhlemann, J.; Miese, F. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Heiss, C.; Kelm, M. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Antoch, G.; Lanzman, R.S. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany)

    2012-05-15

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 {+-} 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis ({>=}50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  1. Single-shot characterization of enzymatic reaction constants Km and kcat by an acoustic-driven, bubble-based fast micromixer.

    Science.gov (United States)

    Xie, Yuliang; Ahmed, Daniel; Lapsley, Michael Ian; Lin, Sz-Chin Steven; Nawaz, Ahmad Ahsan; Wang, Lin; Huang, Tony Jun

    2012-09-04

    In this work we present an acoustofluidic approach for rapid, single-shot characterization of enzymatic reaction constants K(m) and k(cat). The acoustofluidic design involves a bubble anchored in a horseshoe structure which can be stimulated by a piezoelectric transducer to generate vortices in the fluid. The enzyme and substrate can thus be mixed rapidly, within 100 ms, by the vortices to yield the product. Enzymatic reaction constants K(m) and k(cat) can then be obtained from the reaction rate curves for different concentrations of substrate while holding the enzyme concentration constant. We studied the enzymatic reaction for β-galactosidase and its substrate (resorufin-β-D-galactopyranoside) and found K(m) and k(cat) to be 333 ± 130 μM and 64 ± 8 s(-1), respectively, which are in agreement with published data. Our approach is valuable for studying the kinetics of high-speed enzymatic reactions and other chemical reactions.

  2. The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma

    International Nuclear Information System (INIS)

    De Foer, Bert; Bernaerts, Anja; Maes, Joachim; Deckers, Filip; Pouillon, Marc; Vercruysse, Jean-Philippe; Somers, Thomas; Offeciers, Erwin; Michiels, Johan; Casselman, Jan W.

    2007-01-01

    Single-shot (SS) turbo spin-echo (TSE) diffusion-weighted (DW) magnetic resonance imaging (MRI) is a non echo-planar imaging (EPI) technique recently reported for the evaluation of middle ear cholesteatoma. We prospectively evaluated a SS TSE DW sequence in detecting congenital or acquired middle ear cholesteatoma and evaluated the size of middle ear cholesteatoma detectable with this sequence. The aim of this study was not to differentiate between inflammatory tissue and cholesteatoma using SS TSE DW imaging. A group of 21 patients strongly suspected clinically and/or otoscopically of having a middle ear cholesteatoma without any history of prior surgery were evaluated with late post-gadolinium MRI including this SS TSE DW sequence. A total of 21 middle ear cholesteatomas (5 congenital and 16 acquired) were found at surgery with a size varying between 2 and 19 mm. Hyperintense signal on SS TSE DW imaging compatible with cholesteatoma was found in 19 patients. One patient showed no hyperintensity due to autoevacuation of the cholesteatoma sac into the external auditory canal. Another patient showed no hyperintensity because of motion artifacts. This study shows the high sensitivity of this SS TSE DW sequence in detecting small middle ear cholesteatomas, with a size limit as small as 2 mm. (orig.)

  3. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout.

    Science.gov (United States)

    Sukachev, D D; Sipahigil, A; Nguyen, C T; Bhaskar, M K; Evans, R E; Jelezko, F; Lukin, M D

    2017-12-01

    The negatively charged silicon-vacancy (SiV^{-}) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (∼250  ns) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV^{-} electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV^{-} symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV^{-} spin with 89% fidelity. Coherent control of the SiV^{-} spin with microwave fields is used to demonstrate a spin coherence time T_{2} of 13 ms and a spin relaxation time T_{1} exceeding 1 s at 100 mK. These results establish the SiV^{-} as a promising solid-state candidate for the realization of quantum networks.

  4. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  5. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Klasen, J.; Blondin, D.; Schmitt, P.; Bi, X.; Sansone, R.; Wittsack, H.-J.; Kröpil, P.; Quentin, M.; Kuhlemann, J.; Miese, F.; Heiss, C.; Kelm, M.; Antoch, G.; Lanzman, R.S.

    2012-01-01

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 ± 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis (≥50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  6. The killing efficiency of soft iron shot

    Science.gov (United States)

    Andrews, R.; Longcore, J.R.

    1969-01-01

    A cooperative research effort between the ammunition industry and the Bureau of Sport Fisheries and Wildlife is aimed at finding a suitable non-toxic substitute for lead shot. A contract study by an independent research organization evaluated ways of coating or detoxifying lead shot or replacing it with another metal. As a result of that study, the only promising candidate is soft iron. Previous tests of hard iron shot had suggested that its killing effectiveness was poor at longer ranges due to the lower density. In addition, its hardness caused excessive damage to shotgun barrels. A unique, automated shooting facility was constructed at the Patuxent Wildlife Research Center to test the killing effectiveness of soft iron shot under controlled conditions. Tethered game-farm mallards were transported across a shooting point in a manner simulating free flight. A microswitch triggered a mounted shotgun so that each shot was 'perfect.' A soft iron shot, in Number 4 size, was produced by the ammunition industry and loaded in 12-gauge shells to give optimum ballistic performance. Commercial loads of lead shot in both Number 4 and Number 6 size were used for comparison. A total of 2,010 ducks were shot at ranges of 30 to 65 yards and at broadside and head-on angles in a statistically designed procedure. The following data were recorded for each duck: time until death, broken wing or leg bones, and number of embedded shot. Those ducks not killed outright were held for 10 days. From these data, ducks were categorized as 'probably bagged,' 'probably lost cripples,' or survivors. The test revealed that the killing effectiveness of this soft iron shot was superior to its anticipated performance and close to that obtained with commercial lead loads containing an equal number of pellets. Bagging a duck, in terms of rapid death or broken wing, was primarily dependent on the probability of a shot striking that vital area, and therefore a function of range. There was no indication

  7. Label-free nanoscale characterization of red blood cell structure and dynamics using single-shot transport of intensity equation

    Science.gov (United States)

    Poola, Praveen Kumar; John, Renu

    2017-10-01

    We report the results of characterization of red blood cell (RBC) structure and its dynamics with nanometric sensitivity using transport of intensity equation microscopy (TIEM). Conventional transport of intensity technique requires three intensity images and hence is not suitable for studying real-time dynamics of live biological samples. However, assuming the sample to be homogeneous, phase retrieval using transport of intensity equation has been demonstrated with single defocused measurement with x-rays. We adopt this technique for quantitative phase light microscopy of homogenous cells like RBCs. The main merits of this technique are its simplicity, cost-effectiveness, and ease of implementation on a conventional microscope. The phase information can be easily merged with regular bright-field and fluorescence images to provide multidimensional (three-dimensional spatial and temporal) information without any extra complexity in the setup. The phase measurement from the TIEM has been characterized using polymeric microbeads and the noise stability of the system has been analyzed. We explore the structure and real-time dynamics of RBCs and the subdomain membrane fluctuations using this technique.

  8. Gradient rotating outer volume excitation (GROOVE): A novel method for single-shot two-dimensional outer volume suppression.

    Science.gov (United States)

    Powell, Nathaniel J; Jang, Albert; Park, Jang-Yeon; Valette, Julien; Garwood, Michael; Marjańska, Małgorzata

    2015-01-01

    To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing the entire outer volume. Theoretical and k-space descriptions of GROOVE are provided. The properties of GROOVE were investigated with simulations, phantom, and human experiments performed using a 4T horizontal bore magnet equipped with a TEM coil. Similar suppression performance was obtained in phantom and human brain using GROOVE with circular and elliptical shapes. Simulations indicate that GROOVE requires less SAR and time than traditional OVS schemes, but traditional schemes provide a sharper transition zone and less residual signal. GROOVE represents a new way of performing OVS in which spins are excited temporally in space on a trajectory that can be tailored to fit the shape of the suppression region. In addition, GROOVE is capable of suppressing tailored regions of space with more flexibility and in a shorter period of time than conventional methods. GROOVE provides a fast, low SAR alternative to conventional OVS methods in some applications (e.g., scalp suppression). © 2014 Wiley Periodicals, Inc.

  9. Non-chromatographic preparation of a bacterially produced single-shot modular virus-like particle capsomere vaccine for avian influenza.

    Science.gov (United States)

    Wibowo, Nani; Wu, Yang; Fan, Yuanyuan; Meers, Joanne; Lua, Linda H L; Middelberg, Anton P J

    2015-11-04

    Highly pathogenic avian influenza (HPAI) causes significant economic loss, reduced food security and poses an ongoing pandemic threat. Poultry vaccination significantly decreases these problems and recognizes that the health of humans, animals and ecosystems are connected. Low-cost manufacture of poultry vaccine matched quickly to the ever-changing circulating strain is needed for effective vaccination. Here, we re-engineered the process to manufacture bacterially synthesized modular capsomere comprising influenza M2e, previously shown to confer complete protection in challenged mice, for application in poultry. Modular capsomere was prepared using a simplified non-chromatographic salting-out precipitation method and its immunogenicity tested in vivo in poultry. Modular capsomere crudely purified by precipitation (pCapM2e) contained more contaminants than equivalent product purified by chromatography (cCapM2e). Unadjuvanted pCapM2e containing 80 EU of endotoxin per dose was inferior to highly purified and adjuvanted cCapM2e (2 EU per dose). However, addition of adjuvant to pCapM2e resulting in high immunogenicity after only a single dose of vaccination, yet without any local adverse reaction. This finding suggests a strong synergy between adjuvant, antigen and contaminants, and the possible existence of a "Goldilocks" level of contaminants, where high immunogenicity and low reactogenicity can be obtained in a single-shot vaccination. The simplified process offers potential cost and speed advantages to address the needs in influenza poultry vaccination in low-cost veterinary markets. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Growth and characterisation of lead iodide single crystals

    International Nuclear Information System (INIS)

    Tonn, Justus

    2012-01-01

    The work in hand deals with the growth and characterisation of lead iodide (PbI 2 ) single crystals. PbI 2 is regarded as a promising candidate for low-noise X- and gamma ray detection at room temperature. Its benefits if compared to conventional materials like HgI 2 , CdTe, Si, or GaAs lie in a band gap energy of 2.32 eV, an excellent ability to absorb radiation, and a high electrical resistivity. For an application of PbI 2 as detector material the growth and characterisation of crystals with high chemical and structural quality is extremely challenging. In light of this, the effectiveness of zone purification of the PbI 2 used for crystal growth was confirmed by spectroscopic analysis. Furthermore, technological aspects during processing of purified PbI 2 were investigated. With the help of thermal analysis, a correlation was found between the degree of exposing the source material to oxygen from the air and the structural quality of the resulting crystals. A hydrogen treatment was applied to PbI 2 as an effective method for the removal of oxidic pollutions, which resulted in a significant reduction of structural defects like polytypic growth and stress-induced cracking. The growth of PbI 2 single crystals was, among others, carried out by the Bridgman-Stockbarger method. In this context, much effort was put on the investigation of influences resulting from the design and preparation of ampoules. For the first time, crystal growth of PbI 2 was also carried out by the Czochralski method. If compared to the Bridgman-Stockbarger method, the Czochralski technique allowed a significantly faster growth of nearly crack-free crystals with a reproducible predetermination of crystallographic orientation. By an optimised sample preparation of PbI 2 , surface orientations perpendicular to the usually cleaved (0001) plane were realised. It is now possible to determine the material properties along directions which were so far not accessible. Thus, for example, the ratio of

  11. Effect of the peening intensity by shot peening

    International Nuclear Information System (INIS)

    Cheong, Seong Kyun; Chung, Suk Choo; Lee, Seung Ho

    2001-01-01

    The shot peening process is most often used to improve fatigue properties of metal parts. The single most critical parameter of the shot peening process is the shot ball itself. Without the correct quality media, all other shot peening parameters are extraneous and the desired fatigue improvement and consistency of improvement will not be achieved. shot peening involves modifications of the surface and subsurface condition of a material that can be described by the change of the residual stresses, the hardness, and the surface roughness. This paper presents the shot peening to optimize the shot ball parameters. The effect of shot peening parameter on the surface roughness, surface hardness and residual stress are investigated

  12. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  13. Diffusion tensor trace mapping in normal adult brain using single-shot EPI technique: A methodological study of the aging brain

    International Nuclear Information System (INIS)

    Chen, Z.G.; Hindmarsh, T.; Li, T.Q.

    2001-01-01

    Purpose: To quantify age-related changes of the average diffusion coefficient value in normal adult brain using orientation-independent diffusion tensor trace mapping and to address the methodological influences on diffusion quantification. Material and Methods: Fifty-four normal subjects (aged 20-79 years) were studied on a 1.5-T whole-body MR medical unit using a diffusion-weighted single-shot echo-planar imaging technique. Orientation-independent diffusion tensor trace maps were constructed for each subject using diffusion-weighted MR measurements in four different directions using a tetrahedral gradient combination pattern. The global average (including cerebral spinal fluid) and the tissue average of diffusion coefficients in adult brains were determined by analyzing the diffusion coefficient distribution histogram for the entire brain. Methodological influences on the measured diffusion coefficient were also investigated by comparing the results obtained using different experimental settings. Results: Both global and tissue averages of the diffusion coefficient are significantly correlated with age (p<0.03). The global average of the diffusion coefficient increases 3% per decade after the age of 40, whereas the increase in the tissue average of diffusion coefficient is about 1% per decade. Experimental settings for self-diffusion measurements, such as data acquisition methods and number of b-values, can slightly influence the statistical distribution histogram of the diffusion tensor trace and its average value. Conclusion: Increased average diffusion coefficient in adult brains with aging are consistent with findings regarding structural changes in the brain that have been associated with aging. The study also demonstrates that it is desirable to use the same experimental parameters for diffusion coefficient quantification when comparing between different subjects and groups of interest

  14. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    International Nuclear Information System (INIS)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet; Moineddin, Rahim; Babyn, Paul S.

    2013-01-01

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  15. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  16. Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study.

    Science.gov (United States)

    Yoshida, Tsukasa; Urikura, Atsushi; Shirata, Kensei; Nakaya, Yoshihiro; Terashima, Shingo; Hosokawa, Yoichiro

    2016-09-01

    This study aimed to evaluate the image quality and apparent diffusion coefficient (ADC) values of single-shot turbo spin echo (TSE) diffusion-weighted (DW) images obtained using a parallel imaging (PI) technique. All measurements were performed on a 3.0-T whole-body MRI system and 32-channel phased-array coil. Signal-to-noise ratio (SNR) and ADC values were measured with a DW imaging (DWI) phantom comprising granulated sugar and agar. The SNRs were calculated using a subtraction method and compared among TSE-DW images at acceleration factors (AFs) of 1-4. Image blur was visually assessed on TSE-DW images of a pin phantom at AFs of 1-4. The ADC values were calculated using DW images with b = 0 and 1000 s mm(-2). The ADC values of TSE-DW images and echo-planar imaging EPI-DW images were compared. The SNRs decreased as AFs increased, despite selecting the shortest echo time. A lower AF caused increased image blur in the phase-encoding direction. The ADC values of TSE-DWI tended to be lower than those of EPI-DWI, and AFs of 3 and 4 yielded variable ADC values on TSE-DW images. TSE-DWI with an AF of 3 or 4 yielded reduced SNRs; in addition, the image noise and artefacts associated with PI technique may have affected ADC measurements, despite improving image blur in the phase-encoding direction. Optimizing the imaging parameters of TSE-DWI is useful for providing good image quality and accurate ADC measurements.

  17. Hunting shot – evolution of manufacturing technology

    Directory of Open Access Journals (Sweden)

    Piotr Bochyński

    2016-09-01

    Full Text Available Hunting shot are 1.2–10 mm diameter balls, usually made of lead alloys, forming a cluster projectile used in smoothbore hunting shotguns. Shot may also be used in pistol and revolver ammunition, in which it can constitute structural element of the projectile. Shot pellets may also be made of other materials and have other shapes. The aim of this paper is to aggregate information on the topic available from a number of different sources. It is hoped that such information will be useful for forensic ballistics experts. Historical development of pellets and their manufacturing technology from the 15th century is presented.

  18. ECG-gated quiescent-interval single-shot MR angiography of the lower extremities: Initial experience at 3 T

    International Nuclear Information System (INIS)

    Knobloch, G.; Gielen, M.; Lauff, M.-T.; Romano, V.C.; Schmitt, P.; Rick, M.; Kröncke, T.J.; Huppertz, A.; Hamm, B.; Wagner, M.

    2014-01-01

    Aim: To evaluate the feasibility of unenhanced electrocardiography (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) of the lower extremities at 3 T. Materials and methods: Twenty-five patients with known or suspected peripheral arterial disease underwent ECG-gated QISS-MRA and contrast-enhanced MRA (CE-MRA) at 3 T. Two independent readers performed a per-segment evaluation of the MRA datasets. Image quality was rated on a four-point scale (1 = excellent to 4 = non-diagnostic; presented as medians with interquartile range). Diagnostic performance of QISS-MRA was evaluated using CE-MRA as the reference standard. Results: QISS-MRA and CE-MRA of all patients were considered for analysis, resulting in 807 evaluated vessel segments for each MRA technique. Readers 1 and 2 rated image quality of QISS-MRA as diagnostic in 97.3% and 97% of the vessel segments, respectively. CE-MRA was rated diagnostic in all vessel segments. Image quality of the proximal vessel segments, including the infrarenal aorta, iliac arteries, and common femoral artery, was significantly lower on QISS-MRA compared to CE-MRA [image quality score across readers: 2 (1,3) versus 1 (1,1) p < 0.001]. In the more distal vessel segments, image quality of QISS-MRA was excellent and showed no significant difference compared to CE-MRA [image quality score across readers: 1 (1,1) versus 1 (1,1) p = 0.036]. Diagnostic performance of QISS-MRA was as follows (across readers): sensitivity: 87.5% (95% CI: 80.2–92.4%); specificity: 96.1% (95% CI: 93.6–97.6%); diagnostic accuracy: 94.9% (95% CI: 92.6–96.5%). Conclusions: QISS-MRA of the lower extremities is feasible at 3 T and provides high image quality, especially in the distal vessel segments

  19. Shot-put kinematics

    Science.gov (United States)

    DeLuca, R.

    2005-11-01

    The problem of the optimum throw in the shot-put discipline is analysed by relaxing the assumption that the height H, from which the athlete releases the shot, does not depend on the angle θ which the arm of the putter makes with the horizontal axis. In this context, the kinematics of the shot-put is studied and results are compared with the traditional analysis, which considers the height H, the angle θ and the modulus V0 of the initial velocity of the metal sphere as independent parameters.

  20. The “curved lead pathway” method to enable a single lead to reach any two intracranial targets

    Science.gov (United States)

    Ding, Chen-Yu; Yu, Liang-Hong; Lin, Yuan-Xiang; Chen, Fan; Lin, Zhang-Ya; Kang, De-Zhi

    2017-01-01

    Deep brain stimulation is an effective way to treat movement disorders, and a powerful research tool for exploring brain functions. This report proposes a “curved lead pathway” method for lead implantation, such that a single lead can reach in sequence to any two intracranial targets. A new type of stereotaxic system for implanting a curved lead to the brain of human/primates was designed, the auxiliary device needed for this method to be used in rat/mouse was fabricated and verified in rat, and the Excel algorithm used for automatically calculating the necessary parameters was implemented. This “curved lead pathway” method of lead implantation may complement the current method, make lead implantation for multiple targets more convenient, and expand the experimental techniques of brain function research.

  1. Get Important Shots

    Science.gov (United States)

    ... or older adults Work in a school, hospital, prison, or health clinic Travel outside the United States ... health care reform law passed in 2010, most private insurance plans must cover recommended shots for adults. ...

  2. Shot-to-shot intensity and wavefront stability of high-harmonic generation.

    Science.gov (United States)

    Künzel, S; Williams, G O; Boutu, W; Galtier, E; Barbrel, B; Lee, H J; Nagler, B; Zastrau, U; Dovillaire, G; Lee, R W; Merdji, H; Zeitoun, Ph; Fajardo, M

    2015-05-20

    We report on the shot-to-shot stability of intensity and spatial phase of high-harmonic generation (HHG). The intensity stability is measured for each high-harmonic (HH) order with a spectrometer. Additionally, the spatial phase is measured with an XUV wavefront sensor for a single HH order measured in a single shot, which according to our knowledge was not reported before with a Hartmann wavefront sensor. Furthermore, we compare the single-shot measurement of the spatial phase with time-integrated measurements and we show that the XUV wavefront sensor is a useful tool to simultaneously optimize the spatial phase and intensity of HHG within the available HHG parameter range used in this study.

  3. Seasonal ingestion of toxic and nontoxic shot by Canada geese

    Science.gov (United States)

    DeStefano, S.; Brand, C.J.; Samuel, M.D.

    1995-01-01

    We used rates of ingested shot and elevated blood-lead levels (≥0.18 ppm) to estimate the proportion of Canada geese (Branta canadensis) exposed to lead on 3 study areas in Manitoba, Minnesota, and Missouri. Lead exposure was prevalent on all areas and was common after the hunting season closed, when up to 15% of geese could have been exposed to lead shot. However, the proportion of steel shot ingested by geese has increased during the past 2 decades. We suggest that lead exposure is still a source of indirect hunting mortality in Canada geese but project that the prevalence of lead exposure in the Eastern Prairie Population and other waterfowl populations will decrease as nontoxic shot regulations persist and hunters use steel or other nontoxic shot.

  4. A Single Counterexample Leads to Moral Belief Revision.

    Science.gov (United States)

    Horne, Zachary; Powell, Derek; Hummel, John

    2015-11-01

    What kind of evidence will lead people to revise their moral beliefs? Moral beliefs are often strongly held convictions, and existing research has shown that morality is rooted in emotion and socialization rather than deliberative reasoning. In addition, more general issues-such as confirmation bias-further impede coherent belief revision. Here, we explored a unique means for inducing belief revision. In two experiments, participants considered a moral dilemma in which an overwhelming majority of people judged that it was inappropriate to take action to maximize utility. Their judgments contradicted a utilitarian principle they otherwise strongly endorsed. Exposure to this scenario led participants to revise their belief in the utilitarian principle, and this revision persisted over several hours. This method provides a new avenue for inducing belief revision. Copyright © 2015 Cognitive Science Society, Inc.

  5. Intra-Articular, Single-Shot Hylan G-F 20 Hyaluronic Acid Injection Compared with Corticosteroid in Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Kanitnate, Supakit; Yakumpor, Thanasak; Panichkul, Phonthakorn

    2016-06-01

    The treatment of knee osteoarthritis with hyaluronic acid or corticosteroid injection has been widely used. The purpose of this study was to compare the efficacy of hyaluronic acid (hylan G-F 20) with triamcinolone acetonide as a single intra-articular injection for knee osteoarthritis. This study was a prospective, randomized, double-blind clinical trial. Participants with symptomatic knee osteoarthritis were recruited. They were randomized to receive a single-shot, intra-articular injection of either 6 mL of hylan G-F 20 or 6 mL of a solution comprising 1 mL of 40-mg triamcinolone acetonide and 5 mL of 1% lidocaine with epinephrine. The primary outcomes were knee pain severity, knee function, and range of motion at 6 months. Ninety-nine patients were assessed before injection and underwent a 6-month follow-up. Patients and evaluators were blinded. Multilevel regression models were used to estimate differences between the groups. At the 6-month follow-up, compared with patients who took hylan G-F 20, patients who took triamcinolone acetonide had similar improvement in knee pain, knee function, and range of motion. The difference in mean outcome scores between groups was, with regard to knee pain, a visual analog scale (VAS) score of 3 points (95% confidence interval [95% CI], -6 to 11 points); with regard to knee function, a modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score of 0 points (95% CI, -8 to 6 points); and, with regard to range of motion, flexion of -1° (95% CI, -5° to 2°) and extension of 0° (95% CI, -0.5° to 0.5°). However, patients who took triamcinolone acetonide had better pain improvement from 24 hours until 1 week after injection; the mean difference between groups with regard to the VAS score was 12 points (95% CI, 5 to 20 points; p = 0.002) at 24 hours and 9 points (95% CI, 1 to 15 points; p = 0.018) at 1 week. At 2 weeks after injection, patients who took triamcinolone acetonide also had better knee

  6. Shot Noise Thermometry for Thermal Characterization of Templated Carbon Nanotubes

    OpenAIRE

    Sayer, Robert A; Kim, Sunkook; Franklin, Aaron D; Mohammadi, Saeed; Fisher, Timothy

    2010-01-01

    A carbon nanotube (CNT) thermometer that operates on the principles of electrical shot noise is reported. Shot noise thermometry is a self-calibrating measurement technique that relates statistical fluctuations in dc current across a device to temperature. A structure consisting of vertical, top, and bottom-contacted single-walled carbon nanotubes in a porous anodic alumina template was fabricated and used to measure shot noise. Frequencies between 60 and 100 kHz were observed to preclude sig...

  7. Multiple echo multi-shot diffusion sequence.

    Science.gov (United States)

    Chabert, Steren; Galindo, César; Tejos, Cristian; Uribe, Sergio A

    2014-04-01

    To measure both transversal relaxation time (T2 ) and diffusion coefficients within a single scan using a multi-shot approach. Both measurements have drawn interest in many applications, especially in skeletal muscle studies, which have short T2 values. Multiple echo single-shot schemes have been proposed to obtain those variables simultaneously within a single scan, resulting in a reduction of the scanning time. However, one problem with those approaches is the associated long echo read-out. Consequently, the minimum achievable echo time tends to be long, limiting the application of these sequences to tissues with relatively long T2 . To address this problem, we propose to extend the multi-echo sequences using a multi-shot approach, so that to allow shorter echo times. A multi-shot dual-echo EPI sequence with diffusion gradients and echo navigators was modified to include independent diffusion gradients in any of the two echoes. The multi-shot approach allows us to drastically reduce echo times. Results showed a good agreement for the T2 and mean diffusivity measurements with gold standard sequences in phantoms and in vivo data of calf muscles from healthy volunteers. A fast and accurate method is proposed to measure T2 and diffusion coefficients simultaneously, tested in vitro and in healthy volunteers. Copyright © 2013 Wiley Periodicals, Inc.

  8. Interscalene brachial plexus block for open-shoulder surgery: a randomized, double-blind, placebo-controlled trial between single-shot anesthesia and patient-controlled catheter system.

    Science.gov (United States)

    Goebel, Sascha; Stehle, Jens; Schwemmer, Ulrich; Reppenhagen, Stephan; Rath, Beatrice; Gohlke, Frank

    2010-04-01

    Interscalene brachial plexus block (ISB) is widely used as an adjuvant regional pain therapy in patients undergoing major shoulder surgery and has proved its effectiveness on postoperative pain reduction and opioid-sparing effect. This single-center, prospective, double-blind, randomized and placebo-controlled study was to compare the effectiveness of a single-shot and a patient-controlled catheter insertion ISB system after major open-shoulder surgeries. Seventy patients were entered to receive an ISB and a patient-controlled interscalene catheter. The catheter was inserted under ultrasound guidance. Patients were then assigned to receive one of two different postoperative infusions, either 0.2% ropivacaine (catheter group) or normal saline solution (single-shot group) via a disposable patient-controlled infusion pump. The study variables were amount of rescue medication, pain at rest and during physiotherapy, patient satisfaction and incidence of unwanted side effects. The ropivacaine group revealed significantly less consumption of rescue medication within the first 24 h after surgery. Incidence of side effects did not differ between the two groups. Based on our results, we recommend the use of interscalene plexus block in combination with a patient-controlled catheter system under ultrasound guidance only for the first 24 h after major open-shoulder surgery.

  9. Pulsar radiation as polarized shot noise

    International Nuclear Information System (INIS)

    Cordes, J.M.

    1976-01-01

    Pulsar radiation can be resonably modeled as amplitude-modulated shot noise for which the amplitude modulations correspond to the subpulses and micropulses that comprise the structure of single pulses. The shot noise fluctuates on nanosecond time scales and therefore has a bandwidth typical of pulsars, namely, 1-10 GHz. If curvature radiation from bunches of coherently radiating particles is the relevant radiation mechanism, then the radiation from a single bunch corresponds to a shot pulse; such a physical interpretation is not crucial to the validity of the shot noise model, however. We calculate some statistics of the corresponding signal in a narrow-band receiver system, an informative one being the intensity modulation index of the narrow-band noise from which it can be determined whether or not the noise has Gaussian statistics. Departures from Gaussian statistics can occur if intensity variations are due primarily to changes in the number of particles radiating coherently at any instant. If the temporal density of shot pulses is sufficiently high, however, only Gaussian statistics will be observed, meaning that extensive incoherent addition occurs in the generation and the propagation of the radiation.The first and second moments of the Stokes parameters of narrow-band signals are derived for both time-independent and time-variable polarization. It is shown how the polarization properties of short time scale structure can be determined from the autocorrelation functions of the Stokes parameters

  10. SnapShot:Macropinocytosis.

    Science.gov (United States)

    Marques, Pedro E; Grinstein, Sergio; Freeman, Spencer A

    2017-05-04

    Macropinocytosis is the bulk ingestion of extracellular fluids via large endocytic vacuoles. This SnapShot provides an overview of physiological macropinocytosis in immune surveillance and its pathogenic contribution during infection and cancer proliferation. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Kids Guide to Shots

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body ... Safe Videos for Educators Search English Español A Kid's Guide to Shots KidsHealth / For Kids / A Kid's ...

  12. A systematic examination of the bone destruction pattern of the two-shot technique

    Directory of Open Access Journals (Sweden)

    Marcus Stoetzer

    2014-01-01

    Full Text Available Introduction: The two-shot technique is an effective stopping power method. The precise mechanisms of action on the bone and soft-tissue structures of the skull; however, remain largely unclear. The aim of this study is to compare the terminal ballistics of the two-shot and single-shot techniques. Materials and Methods: 40 fresh pigs′ heads were randomly divided into 4 groups (n = 10. Either a single shot or two shots were fired at each head with a full metal jacket or a semi-jacketed bullet. Using thin-layer computed tomography and photography, the diameter of the destruction pattern and the fractures along the bullet path were then imaged and assessed. Results: A single shot fired with a full metal jacket bullet causes minor lateral destruction along the bullet path. With two shots fired with a full metal jacket bullet, however, the maximum diameter of the bullet path is significantly greater (P < 0.05 than it is with a single shot fired with a full metal jacket bullet. In contrast, the maximum diameter with a semi-jacketed bullet is similar with the single-shot and two-shot techniques. Conclusion: With the two-shot technique, a full metal jacket bullet causes a destruction pattern that is comparable to that of a single shot fired with a semi-jacketed bullet.

  13. ZAPP shot summary

    Energy Technology Data Exchange (ETDEWEB)

    Loisel, Guillaume Pascal [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2015-10-01

    This was the second Z Astrophysical Plasma Properties (ZAPP) fundamental science shot series of 2015. ZAPP experiments measure fundamental properties of atoms in plasmas to solve the following important astrophysical puzzles: Why can’t we accurately model the opacity of Fe at the convection zone boundary in the Sun? How accurate are the photoionization models used to interpret data from xray satellite observations? and Why doesn’t spectral fitting provide the correct properties for White Dwarfs?

  14. One-shot synesthesia

    Directory of Open Access Journals (Sweden)

    Kirschner Alexandra

    2017-11-01

    Full Text Available Synesthesia is commonly thought to be a phenomenon of fixed associations between an outside inducer and a vivid concurrent experience. Hence, it has been proposed that synesthesia occurs due to additional connections in the brain with which synesthetes are born. Here we show that synesthesia can be a much richer and more flexible phenomenon with a capability to creatively construct novel synesthetic experiences as events unfold in people’s lives. We describe here cases of synesthetes who occasionally generate novel synesthetic experience, called one-shot synesthesias. These synesthetic experiences seem to share all the properties with the classical synesthetic associations except that they occur extremely rarely, people recalling only a few events over the lifetime. It appears that these one-shots are not created at random but are instead responses to specific life events. We contrast the properties of those rare synesthetic events with other, more commonly known forms of synesthesia that also create novel synesthetic experiences, but at a high rate—sometimes creating novel experiences every few seconds. We argue that one-shot synesthesias indicate that synesthetic associations are by their nature not prewired at birth but are dynamically constructed through mental operations and according to the needs of a synesthetic mind. Our conclusions have implications for understanding the biological underpinnings of synesthesia and the role the phenomenon plays in the lives of people endowed with synesthetic capacities.

  15. Single-shot echo-planar imaging with Nyquist ghost compensation: interleaved dual echo with acceleration (IDEA) echo-planar imaging (EPI).

    Science.gov (United States)

    Poser, Benedikt A; Barth, Markus; Goa, Pål-Erik; Deng, Weiran; Stenger, V Andrew

    2013-01-01

    Echo planar imaging (EPI) is most commonly used for blood oxygen level-dependent fMRI, owing to its sensitivity and acquisition speed. A major problem with EPI is Nyquist (N/2) ghosting, most notably at high field. EPI data are acquired under an oscillating readout gradient and hence vulnerable to gradient imperfections such as eddy current delays and off-resonance effects, as these cause inconsistencies between odd and even k-space lines after time reversal. We propose a straightforward and pragmatic method herein termed "interleaved dual echo with acceleration (IDEA) EPI": two k-spaces (echoes) are acquired under the positive and negative readout lobes, respectively, by performing phase encoding blips only before alternate readout gradients. From these two k-spaces, two almost entirely ghost free images per shot can be constructed, without need for phase correction. The doubled echo train length can be compensated by parallel imaging and/or partial Fourier acquisition. The two k-spaces can either be complex averaged during reconstruction, which results in near-perfect cancellation of residual phase errors, or reconstructed into separate images. We demonstrate the efficacy of IDEA EPI and show phantom and in vivo images at both 3 T and 7 T. Copyright © 2012 Wiley Periodicals, Inc.

  16. Strategies to improve phase-stability of ultrafast swept source optical coherence tomography for single shot imaging of transient mechanical waves at 16 kHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Song, Shaozhen; Wei, Wei; Hsieh, Bao-Yu; Pelivanov, Ivan; O' Donnell, Matthew [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Shen, Tueng T.; Wang, Ruikang K., E-mail: wangrk@uw.edu [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Ophthalmology, University of Washington, Seattle, Washington 98104 (United States)

    2016-05-09

    We present single-shot phase-sensitive imaging of propagating mechanical waves within tissue, enabled by an ultrafast optical coherence tomography (OCT) system powered by a 1.628 MHz Fourier domain mode-locked (FDML) swept laser source. We propose a practical strategy for phase-sensitive measurement by comparing the phases between adjacent OCT B-scans, where the B-scan contains a number of A-scans equaling an integer number of FDML buffers. With this approach, we show that micro-strain fields can be mapped with ∼3.0 nm sensitivity at ∼16 000 fps. The system's capabilities are demonstrated on porcine cornea by imaging mechanical wave propagation launched by a pulsed UV laser beam, promising non-contact, real-time, and high-resolution optical coherence elastography.

  17. Lead

    Science.gov (United States)

    ... about the health effects of lead in drinking water The law mandates no-lead products for drinking water after ... Waste, and Cleanup Lead Mold Pesticides Radon Science Water A-Z Index Laws & Regulations By Business Sector By Topic Compliance Enforcement ...

  18. Should Single-Coil Implantable Cardioverter Defibrillator Leads Be Used in all Patients?

    Science.gov (United States)

    Almehmadi, Fahad; Manlucu, Jaimie

    2018-03-01

    The historical preference for dual-coil implantable cardioverter defibrillator leads stems from high defibrillation thresholds associated with old device platforms. The high safety margins generated by contemporary devices have rendered the modest difference in defibrillation efficacy between single- and dual-coil leads clinically insignificant. Cohort data demonstrating worse lead extraction outcomes and higher all-cause mortality have brought the incremental utility of an superior vena cava coil into question. This article summarizes the current literature and re-evaluates the utility of dual-coil leads in the context of modern device technology. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Quasi-thermal noise and shot noise spectroscopy on a CubeSat in Earth's ionosphere

    Science.gov (United States)

    Maj, Ronald; Cairns, Iver H.

    2017-03-01

    We investigate the practicality of using quasi-thermal noise (QTN) and shot noise spectroscopy on a CubeSat in the Earth's ionosphere and constrain the satellite antenna length for optimal detection of these signals. The voltage spectra predicted for thermal Langmuir waves (QTN) and particle "shot noise" are modeled, and it is shown that the signals detected can provide two very good, independent, passive, in situ methods of measuring the plasma density and temperature in the ionosphere. The impact of the antenna potential ϕ is also discussed, and we show that the negative potential calculated for the ionosphere due to natural current flows has a significant impact on the voltage power level of the shot noise spectrum. The antenna configuration is also shown to play an important role in the shot noise, with a monopole configuration enhancing the spectrum significantly compared with a dipole. Antenna lengths on the order of 20-40 cm are found to be ideal for ionospheric plasma conditions, nicely matching CubeSat sizes and producing detectable thermal Langmuir waves and shot noise at the microvolt level. Further, with a continuous stream of data points at different latitudes and longitudes an orbiting CubeSat can produce a global picture for the ionospheric plasma density and temperature using QTN and shot noise signals. If implemented, especially in a constellation, these data would be more frequent and cover a much greater domain than current ground-based or single-satellite methods. This could lead to improved ionospheric models, such as the empirically based International Reference Ionosphere.

  20. Collider shot setup for Run 2 observations and suggestions

    International Nuclear Information System (INIS)

    Annala, J.; Joshel, B.

    1996-01-01

    This note is intended to provoke discussion on Collider Run II shot setup. We hope this is a start of activities that will converge on a functional description of what is needed for shot setups in Collider Run II. We will draw on observations of the present shot setup to raise questions and make suggestions for the next Collider run. It is assumed that the reader has some familiarity with the Collider operational issues. Shot setup is defined to be the time between the end of a store and the time the Main Control Room declares colliding beams. This is the time between Tevatron clock events SCE and SCB. This definition does not consider the time experiments use to turn on their detectors. This analysis was suggested by David Finley. The operational scenarios for Run II will require higher levels of reliability and speed for shot setup. See Appendix I and II. For example, we estimate that a loss of 3 pb -1 /week (with 8 hour stores) will occur if shot setups take 90 minutes instead of 30 minutes. In other words: If you do 12 shots for one week and accept an added delay of one minute in each shot, you will loose more than 60 nb -1 for that week alone (based on a normal shot setup of 30 minutes). These demands should lead us to be much more pedantic about all the factors that affect shot setups. Shot setup will be viewed as a distinct process that is composed of several inter- dependent 'components': procedures, hardware, controls, and sociology. These components don't directly align with the different Accelerator Division departments, but are topical groupings of the needed accelerator functions. Defining these components, and categorizing our suggestions within them, are part of the goal of this document. Of course, some suggestions span several of these components

  1. Shot-to-shot fluctuations in the directed superradiant emission from extended atomic samples

    International Nuclear Information System (INIS)

    Clemens, J P; Horvath, L; Sanders, B C; Carmichael, H J

    2004-01-01

    We study collective spontaneous emission from arbitrary distributions of N two-state atoms using quantum trajectory theory and without an a priori single-mode assumption. Assuming a fully excited initial state, we calculate the angular distribution of the average intensity, focusing on pencil- and disc-shaped samples. The formalism is developed around an unravelling of the master equation in terms of source mode quantum jumps. A modified boson approximation is made to treat the many-atom case, where it is found that strong directional superradiance with shot-to-shot fluctuations occurs for a few hundred to a few thousand atoms

  2. Neural Circuits via Which Single Prolonged Stress Exposure Leads to Fear Extinction Retention Deficits

    Science.gov (United States)

    Knox, Dayan; Stanfield, Briana R.; Staib, Jennifer M.; David, Nina P.; Keller, Samantha M.; DePietro, Thomas

    2016-01-01

    Single prolonged stress (SPS) has been used to examine mechanisms via which stress exposure leads to post-traumatic stress disorder symptoms. SPS induces fear extinction retention deficits, but neural circuits critical for mediating these deficits are unknown. To address this gap, we examined the effect of SPS on neural activity in brain regions…

  3. System upgrade and its complications in patients with a single lead atrial pacemaker

    DEFF Research Database (Denmark)

    Kirkfeldt, Rikke Esberg; Andersen, Henning Rud; Nielsen, Jens Cosedis

    2013-01-01

    To investigate the indications for system upgrade with single lead atrial pacing (AAIR), complications associated with these re-interventions, and possible predictors for system upgrade among patients included in the Danish Multicenter Randomized Trial on AAIR vs. dual-chamber pacing (DDDR) in si...

  4. Surface severe plastic deformation of AISI 304 via conventional shot peening, severe shot peening and repeening

    Energy Technology Data Exchange (ETDEWEB)

    Unal, Okan, E-mail: unalokan78@gmail.com [Mechanical Engineering Department, Bartın University, Bartın 74100 (Turkey); Varol, Remzi [Mechanical Engineering Department, Suleyman Demirel University, Isparta 32200 (Turkey)

    2015-10-01

    Highlights: • CSP and SSP treatments transform austenite to metastable martensite structure. • Nanograin layer thickness after CSP and SSP is 8 μm and 22 μm, respectively. • Shot peening leads to carbon segregation from coarse to nano grain layer. • Repeening is an effective way to reduce surface roughness. - Abstract: Air blast conventional shot peening (CSP), severe shot peening (SSP) and repeening (RP) as a severe plastic deformation applications on AISI 304 austenitic stainless steel is addressed. Shot peened specimens are investigated based on optical, FESEM and digital microscope. The investigations present the austenite transformation to metastable martensite via mechanical twinning due to plastic deformation with high strain rates. It is found that SSP induces thicker nanograin layer with compared to CSP. In XRD studies, the austenite peaks broaden by means of severe shot peening and FWHM increase reveals the grain size reduction below 25 nm regimes on the surface. In EDAX line analysis of CSP specimen, carbon content increase has been detected from deformed layer through the nanocrystalline layer then the content reduces. The carbon segregation takes place due to the energy level distinction between dislocations and Fe−C bonds. 3d contour digital microscope studies and roughness investigations reveal that SSP has deleterious side effect on the surface roughness and surface flatness. However, RP is an effective way to reduce the surface roughness to reasonable values.

  5. Buster-Jangle Shot Dog

    International Nuclear Information System (INIS)

    Kaul, Dean C.

    1987-01-01

    Shot Dog of the Buster-Jangle Series used a device which had a high-explosive configuration virtually identical to that of the Nagasaki bomb, though with different fissionable components. Dog was detonated at a height of 431.9 m with the mean atmospheric conditions between burst and ground being dry air density 1.027 mg/cc and atmospheric moisture density 0.006 mg/cc. The ground was taken to be that of Nevada test site (NTS) area 9 with a water content of 8% by weight. The yield of the weapon was 21 kt. Results shown here for Buster-Jangle Shot Dog have been scaled from those calculated for Ranger Shot Fox. The design features and burst geometries of the two devices were deemed sufficiently similar to make this substitution in the absence of a radiation leakage spectrum calculated explicitly for Buster-Jangle Shot Dog. However, while the relative atmospheric contents of the two shots were very similar, Shot Fox took place in air of approximately 10% greater density than Shot Dog. Thus, scaled calculated results could not be obtained to compare with the three closest measurement points at Shot Dog

  6. Development of Laser Rifle Trainer with Full Shot Imitation

    Directory of Open Access Journals (Sweden)

    Ramutis Bansevicius

    2004-01-01

    Full Text Available Laser trainers are effective tools for shot and sportsmen training. However, the majority of trainers have neither realistic recoil nor sound imitation systems. The objective of the development of laser rifle trainer with full shot imitation was to investigate and simulate the recoil of combat weapons under single and serial shooting regimes so that the training weapons could simulate complete recoil and sound imitation.

  7. Multi-illumination Gabor holography recorded in a single camera snap-shot for high-resolution phase retrieval in digital in-line holographic microscopy

    Science.gov (United States)

    Sanz, Martin; Picazo-Bueno, Jose A.; Garcia, Javier; Micó, Vicente

    2015-05-01

    In this contribution we introduce MISHELF microscopy, a new concept and design of a lensless holographic microscope based on wavelength multiplexing, single hologram acquisition and digital image processing. The technique which name comes from Multi-Illumination Single-Holographic-Exposure Lensless Fresnel microscopy, is based on the simultaneous illumination and recording of three diffraction patterns in the Fresnel domain. In combination with a novel and fast iterative phase retrieval algorithm, MISHELF microscopy is capable of high-resolution (micron range) phase-retrieved (twin image elimination) biological imaging of dynamic events (video rate recording speed) since it avoids the time multiplexing needed for the in-line hologram sequence recording when using conventional phase-shifting or phase retrieval algorithms. MISHELF microscopy is validated using two different experimental layouts: one using RGB illumination and detection schemes and another using IRRB as illumination while keeping the RGB color camera as detection device. Preliminary experimental results are provided for both experimental layouts using a synthetic object (USAF resolution test target).

  8. Increased distance of shooting on basketball jump shot.

    Science.gov (United States)

    Okazaki, Victor Hugo Alves; Rodacki, André Luiz Félix

    2012-01-01

    The present study analyzed the effect of increased distance on basketball jump shot outcome and performance. Ten male expert basketball players were filmed and a number of kinematic variables analyzed during jump shot that were performed from three conditions to represent close, intermediate and far distances (2.8, 4.6, and 6.4m, respectively). Shot accuracy decreased from 59% (close) to 37% (far), in function of the task constraints (p shot was performed from close (78.92°) in comparison to intermediate distances (65.60°). While, ball release velocity increased (p jump shot accuracy when distance is augmented. Key pointsThe increased distance leads to greater spatial con-straint over shot movement that demands an adapta-tion of the movement for the regulation of the accu-racy and the impulse generation to release the ball.The reduction in balls release height and release angle, in addition to the increase in balls release ve-locity, were suggested as the main factors that de-creased shot accuracy with the distance increased.Players should look for release angles of shooting that provide an optimal balls release velocity to im-prove accuracy.

  9. Changes in susceptibility signs on serial T2*-weighted single-shot echo-planar gradient-echo images in acute embolic infarction: comparison with recanalization status on 3D time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kinoshita, Toshibumi; Kinoshita, Fumiko

    2012-01-01

    The present study compares changes in susceptibility signs on follow-up single-shot echo-planar gradient-echo T2*-weighted images (GRE-EPI) with vascular status on follow-up magnetic resonance angiography (MRA) in acute embolic infarction. Twenty consecutive patients with acute embolic infarction repeatedly underwent MR imaging including GRE-EPI and MRA using a 1.5-T MR superconducting system. All patients underwent initial MR examination within 24 h of onset and follow-up MR imaging within 1 month after onset. Changes in susceptibility signs on follow-up GRE-EPI were compatible with vascular status on follow-up MRA in 19 of the 20 patients. Susceptibility signs disappeared with complete recanalization in 13 patients, migrated with partial recanalization in 3, did not change together with the absence of recanalization in 2, and became extended together with the absence of recanalization in 1. Cerebral hemorrhage obscured susceptibility signs in the one remaining patient. Susceptibility signs on follow-up GRE-EPI can reflect changes in an acute embolus, such as recanalization or migration, in this study. Serial GRE-EPI in acute embolism complements the diagnostic certainty of MRA by directly detecting an embolus as a susceptibility sign. (orig.)

  10. Mode-Locked Multichromatic X-Rays in a Seeded Free-Electron Laser for Single-Shot X-Ray Spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, Dao; Ding, Yuantao; Raubenheimer, Tor; Wu, Juhao; /SLAC

    2012-05-10

    We present the promise of generating gigawatt mode-locked multichromatic x rays in a seeded free-electron laser (FEL). We show that, by using a laser to imprint periodic modulation in electron beam phase space, a single-frequency coherent seed can be amplified and further translated to a mode-locked multichromatic output in an FEL. With this configuration the FEL output consists of a train of mode-locked ultrashort pulses which span a wide frequency gap with a series of equally spaced sharp lines. These gigawatt multichromatic x rays may potentially allow one to explore the structure and dynamics of a large number of atomic states simultaneously. The feasibility of generating mode-locked x rays ranging from carbon K edge ({approx}284 eV) to copper L{sub 3} edge ({approx}931 eV) is confirmed with numerical simulation using the realistic parameters of the linac coherent light source (LCLS) and LCLS-II. We anticipate that the mode-locked multichromatic x rays in FELs may open up new opportunities in x-ray spectroscopy (i.e. resonant inelastic x-ray scattering, time-resolved scattering and spectroscopy, etc.).

  11. A multi-channel THz and infrared spectrometer for femtosecond electron bunch diagnostics by single-shot spectroscopy of coherent radiation

    International Nuclear Information System (INIS)

    Wesch, Stephan; Schmidt, Bernhard; Behrens, Christopher; Delsim-Hashemi, Hossein; Schmueser, Peter

    2011-08-01

    The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of resolving structures in the femtosecond regime. A novel in-vacuum spectrometer has been developed for spectroscopy of coherent radiation in the THz and infrared range. The spectrometer is equipped with five consecutive dispersion gratings and 120 parallel readout channels; it can be operated either in short wavelength mode (5-44 μm) or in long wavelength mode (45-430 μm). Fast parallel readout permits the spectroscopy of coherent radiation from single electron bunches. Test measurements at the soft X-ray free-electron laser FLASH, using coherent transition radiation, demonstrate excellent performance of the spectrometer. The high sensitivity down to a few micrometers allows study of short bunch features caused for example by microbunching e ects in magnetic chicanes. The device is planned for use as an online bunch profile monitor during regular FEL operation. (orig.)

  12. A multi-channel THz and infrared spectrometer for femtosecond electron bunch diagnostics by single-shot spectroscopy of coherent radiation

    Energy Technology Data Exchange (ETDEWEB)

    Wesch, Stephan; Schmidt, Bernhard; Behrens, Christopher; Delsim-Hashemi, Hossein; Schmueser, Peter

    2011-08-15

    The high peak current required in free-electron lasers (FELs) is realized by longitudinal compression of the electron bunches to sub-picosecond length. In this paper, a frequency-domain diagnostic method is described that is capable of resolving structures in the femtosecond regime. A novel in-vacuum spectrometer has been developed for spectroscopy of coherent radiation in the THz and infrared range. The spectrometer is equipped with five consecutive dispersion gratings and 120 parallel readout channels; it can be operated either in short wavelength mode (5-44 {mu}m) or in long wavelength mode (45-430 {mu}m). Fast parallel readout permits the spectroscopy of coherent radiation from single electron bunches. Test measurements at the soft X-ray free-electron laser FLASH, using coherent transition radiation, demonstrate excellent performance of the spectrometer. The high sensitivity down to a few micrometers allows study of short bunch features caused for example by microbunching e ects in magnetic chicanes. The device is planned for use as an online bunch profile monitor during regular FEL operation. (orig.)

  13. A dense plasma focus-based neutron source for a single-shot detection of illicit materials and explosives by a nanosecond neutron pulse

    Energy Technology Data Exchange (ETDEWEB)

    Gribkov, V A; Latyshev, S V [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation); Miklaszewski, R A; Chernyshova, M [Institute of Plasma Physics and Laser Microfusion, Warsaw (Poland); Drozdowicz, K; Wiacek, U [Institute of Nuclear Physics, Krakow (Poland); Tomaszewski, K [ACS Ltd, Warsaw (Poland); Lemeshko, B D [N L Dukhov All-Russian Institute of Automation, Moscow (Russian Federation)], E-mail: gribkovv@yahoo.com

    2010-03-15

    Recent progress in a single-pulse Nanosecond Impulse Neutron Investigation System (NINIS) intended for interrogation of hidden objects by means of measuring elastically scattered neutrons is presented in this paper. The method uses very bright neutron pulses having duration of the order of 10 ns only, which are generated by dense plasma focus (DPF) devices filled with pure deuterium or DT mixture as a working gas. The small size occupied by the neutron bunch in space, number of neutrons per pulse and mono-chromaticity ({delta}E/E{approx}1%) of the neutron spectrum provides the opportunity to use a time-of-flight (TOF) technique with flying bases of about a few metres. In our researches we used DPF devices having bank energy in the range 2-7 kJ. The devices generate a neutron yield of the level of 10{sup 8}-10{sup 9} 2.45 MeV and 10{sup 10}-10{sup 11} 14 MeV neutrons per pulse with pulse duration {approx}10-20 ns. TOF base in the tests was 2.2-18.5 m. We have demonstrated the possibility of registering of neutrons scattered by the substances under investigation-1 litre bottles with methanol (CH{sub 3}OH), phosphoric (H{sub 2}PO{sub 4}) and nitric (HNO{sub 3}) acids as well as a long object-a 1 m gas tank filled with deuterium at high pressure. It is shown that the above mentioned short TOF bases and relatively low neutron yields are enough to distinguish different elements' nuclei composing the substance under interrogation and to characterize the geometry of lengthy objects in some cases. The wavelet technique was employed to 'clean' the experimental data registered. The advantages and restrictions of the proposed and tested NINIS technique in comparison with other methods are discussed.

  14. A dense plasma focus-based neutron source for a single-shot detection of illicit materials and explosives by a nanosecond neutron pulse

    International Nuclear Information System (INIS)

    Gribkov, V A; Latyshev, S V; Miklaszewski, R A; Chernyshova, M; Drozdowicz, K; Wiacek, U; Tomaszewski, K; Lemeshko, B D

    2010-01-01

    Recent progress in a single-pulse Nanosecond Impulse Neutron Investigation System (NINIS) intended for interrogation of hidden objects by means of measuring elastically scattered neutrons is presented in this paper. The method uses very bright neutron pulses having duration of the order of 10 ns only, which are generated by dense plasma focus (DPF) devices filled with pure deuterium or DT mixture as a working gas. The small size occupied by the neutron bunch in space, number of neutrons per pulse and mono-chromaticity (ΔE/E∼1%) of the neutron spectrum provides the opportunity to use a time-of-flight (TOF) technique with flying bases of about a few metres. In our researches we used DPF devices having bank energy in the range 2-7 kJ. The devices generate a neutron yield of the level of 10 8 -10 9 2.45 MeV and 10 10 -10 11 14 MeV neutrons per pulse with pulse duration ∼10-20 ns. TOF base in the tests was 2.2-18.5 m. We have demonstrated the possibility of registering of neutrons scattered by the substances under investigation-1 litre bottles with methanol (CH 3 OH), phosphoric (H 2 PO 4 ) and nitric (HNO 3 ) acids as well as a long object-a 1 m gas tank filled with deuterium at high pressure. It is shown that the above mentioned short TOF bases and relatively low neutron yields are enough to distinguish different elements' nuclei composing the substance under interrogation and to characterize the geometry of lengthy objects in some cases. The wavelet technique was employed to 'clean' the experimental data registered. The advantages and restrictions of the proposed and tested NINIS technique in comparison with other methods are discussed.

  15. A dense plasma focus-based neutron source for a single-shot detection of illicit materials and explosives by a nanosecond neutron pulse

    Science.gov (United States)

    Gribkov, V. A.; Latyshev, S. V.; Miklaszewski, R. A.; Chernyshova, M.; Drozdowicz, K.; Wiącek, U.; Tomaszewski, K.; Lemeshko, B. D.

    2010-03-01

    Recent progress in a single-pulse Nanosecond Impulse Neutron Investigation System (NINIS) intended for interrogation of hidden objects by means of measuring elastically scattered neutrons is presented in this paper. The method uses very bright neutron pulses having duration of the order of 10 ns only, which are generated by dense plasma focus (DPF) devices filled with pure deuterium or DT mixture as a working gas. The small size occupied by the neutron bunch in space, number of neutrons per pulse and mono-chromaticity (ΔE/E~1%) of the neutron spectrum provides the opportunity to use a time-of-flight (TOF) technique with flying bases of about a few metres. In our researches we used DPF devices having bank energy in the range 2-7 kJ. The devices generate a neutron yield of the level of 108-109 2.45 MeV and 1010-1011 14 MeV neutrons per pulse with pulse duration ~10-20 ns. TOF base in the tests was 2.2-18.5 m. We have demonstrated the possibility of registering of neutrons scattered by the substances under investigation—1 litre bottles with methanol (CH3OH), phosphoric (H2PO4) and nitric (HNO3) acids as well as a long object—a 1 m gas tank filled with deuterium at high pressure. It is shown that the above mentioned short TOF bases and relatively low neutron yields are enough to distinguish different elements' nuclei composing the substance under interrogation and to characterize the geometry of lengthy objects in some cases. The wavelet technique was employed to 'clean' the experimental data registered. The advantages and restrictions of the proposed and tested NINIS technique in comparison with other methods are discussed.

  16. Generalised shot noise Cox processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Torrisi, Giovanni Luca

    We introduce a new class of Cox cluster processes called generalised shot-noise processes (GSNCPs), which extends the definition of shot noise Cox processes (SNCPs) in two directions: the point process which drives the shot noise is not necessarily Poisson, and the kernel of the shot noise can...... be random. Thereby a very large class of models for aggregated or clustered point patterns is obtained. Due to the structure of GSNCPs, a number of useful results can be established. We focus first on deriving summary statistics for GSNCPs and next on how to make simulation for GSNCPs. Particularly, results...... for first and second order moment measures, reduced Palm distributions, the -function, simulation with or without edge effects, and conditional simulation of the intensity function driving a GSNCP are given. Our results are exemplified for special important cases of GSNCPs, and we discuss the relation...

  17. Generalised shot noise Cox processes

    DEFF Research Database (Denmark)

    Møller, Jesper; Torrisi, Giovanni Luca

    2005-01-01

    We introduce a class of cox cluster processes called generalised shot noise Cox processes (GSNCPs), which extends the definition of shot noise Cox processes (SNCPs) in two directions: the point process that drives the shot noise is not necessarily Poisson, and the kernel of the shot noise can...... be random. Thereby, a very large class of models for aggregated or clustered point patterns is obtained. Due to the structure of GSNCPs, a number of useful results can be established. We focus first on deriving summary statistics for GSNCPs and, second, on how to simulate such processes. In particular......, results on first- and second-order moment measures, reduced Palm distributions, the J-function, simulation with or without edge effects, and conditional simulation of the intensity function driving a GSNCP are given. Our results are exemplified in important special cases of GSNCPs, and we discuss...

  18. Experimental results on recent applications of shot peening

    International Nuclear Information System (INIS)

    Zaid, A.I.O.

    2001-01-01

    Shot peening is a mechanical surface treatment by which the surface of an elastic plastic component is subjected to multiple impact of high speed hard spheres, hence introducing a compressive stress layer of certain depth below the surface. This compressive stress layer results in enhancement of the fatigue life of the component. In this paper, the mechanism of shot peening and the effect of the parameters related to it are reviewed and discussed. The effect of shot peening on the fatigue life of aluminum alloy 7075-T6 and the phenomenological aspects associated with it are also given and discussed. Also, the effect of shot peening on aluminum alloy 2024-T3 in the as received and peened conditions is presented and discussed. Butt single U and butt double vee joints were both investigated from which it was found that the butt single U joint possessed higher values of fatigue life than the double vee joint for the same shot peening intensity. Finally, experimental results on a recent application that is the effect of shot peening on the fatigue life of stainless steel 17-4PH prior to hard chromium plating are given and discussed. Comparison is also made among these results and those obtained in the case of the chromium plated without peening and as received conditions. It was found that shot peening caused an increase of 667% in the fatigue life of stainless steel 17-4PH at 0.57 Y stress level, whereas hard chromium plating was found to reduce its fatigue life and strength. Hence, chromium plating after shot peening is recommended. (author)

  19. Shot peening of aluminium alloys

    International Nuclear Information System (INIS)

    Le Guernic, Y.

    1998-01-01

    Shot peening is a process of cold-hammering where a metallic surface is pelted with spherical grains. Each grain bumping into the surface acts as a hammer head and creates a small crater. The overlapping of these craters produces a residual compression layer just underneath the surface. It is well known that cracks cannot spread in a compression zone. In most cases of fatigue rupture and stress corrosion cracks propagate from the surface towards the inside so shot peening allows a longer lifetime of castings. Moreover most materials present a better resistance due to the cold-hammering effect of shot peening. Metallic surfaces can be treated in workshops or directly on site. Typical pieces that undergo shot peening on site are storing tanks, gas and steam turbines, tubes of steam generators and piping in oil or nuclear or chemical industries. This article describes shot peening from a theoretical and general point of view and presents the application to aluminium-lithium alloys. In the case of aluminium alloys shot peening can be used to shape the piece (peen-forming). (A.C.)

  20. Surface durability of powder-forged roller treated by shot peening

    International Nuclear Information System (INIS)

    Seki, Masanori; Fujii, Masahiro; Kobayashi, Yuji; Sato, Masaaki; Yoshida, Akira

    2010-01-01

    To investigate the influence of shot peening on the surface durability of powder-forged rollers, the case-hardened powder-forged rollers with a forging density of 7.5 g/cm 3 treated by the single shot peening and the double shot peening were fatigue-tested under a slidingrolling contact condition. The surface roughness, the surface hardness and the surface compressive residual stress of the rollers were increased by the shot peening. In addition, the pores near the roller surface were deformed by the shot peening. The failure mode of all the test rollers was spalling due to subsurface cracking. The fatigue lives of all the test rollers were improved by the shot peening, and that of the test roller S08, which was shot-peened with the hardest steel shots in this experimental range, was especially improved. The surface durability of the test roller S08 was also most improved by the shot peening. Cracks became difficult to occur and propagate under the roller surface since the pores near the roller surface were deformed by the stronger shot peening. In this study, double shot peening, which generally restrains the increase in surface roughness, was not particularly effective for the improvement in the surface durability of the powder-forged rollers, because the influence of tangential force on fatigue was not always great in a case of subsurface cracking

  1. Detection of charged particles with a methylammonium lead tribromide perovskite single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Qiang [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, Ohio 43210 (United States); Wei, Haotong; Wei, Wei [Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, Nebraska 68588 (United States); Chuirazzi, William; DeSantis, Dylan [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, Ohio 43210 (United States); Huang, Jinsong, E-mail: jhuang2@unl.edu [Department of Mechanical and Materials Engineering, University of Nebraska-Lincoln, Lincoln, Nebraska 68588 (United States); Cao, Lei, E-mail: cao.152@osu.edu [Nuclear Engineering Program, Department of Mechanical and Aerospace Engineering, The Ohio State University, Columbus, Ohio 43210 (United States)

    2017-03-11

    Methylammonium lead tribromide (MAPbBr{sub 3}) perovskite crystals have attracted significant attention due to their attractive performance in various optoelectronic applications such as solar cells, light-emitting devices, photodetectors, and recently in X-ray detectors. In this study, we demonstrate a possible use of perovskite-based devices for detection of charged particles (which can be applied in basic scientific research, health physics, and environmental analysis) and investigate the mechanism of fundamental charge transport inside perovskite crystals. It was found that inexpensive MAPbBr{sub 3} single crystals could be used for measuring the energy spectrum of charged particles through direct collection of the produced charge. After fitting the plot of the centroid peak position versus voltage with the Hecht equation for single-polarity charge transport, the obtained hole mobility-lifetime product was in the range of (0.4–1.6)×10{sup −3} cm{sup 2}/V.

  2. Scintillation of lead tungstate crystal studied with single-electron beam from KUFEL

    Energy Technology Data Exchange (ETDEWEB)

    Rizwan, Mohamad, E-mail: rizwan@nucl.kyushu-u.ac.jp; Uozumi, Yusuke; Matsuo, Kazuki [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, Fukuoka (Japan); Ohgaki, Hideaki; Kii, Toshiteru; Zen, Heishun [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto (Japan); Tsamalaidze, Zviadi; Evtoukhovitch, Petr; Valentin, Samoilov [Joint Institute for Nuclear Research, JINR, Joliot-Curie Str.6, Dubna (Russian Federation)

    2015-04-29

    Lead tungstate (PWO) crystal has a very fast response, high atomic density and high radiation hardness. Therefore, they are suitable to be used for high-energy nuclear data measurements under high-background circumstances. Although a good electron-ion separation with a pulse shape analysis technique is essential, scintillation pulse shapes have not been observed with electron beams of a wide energy range. A single-electron beam technique has been developed at Kyoto University Free Electron Laser (KUFEL), and electron beams of 4-38 MeV are available. During the experiments, single electron beams bombarded a PWO crystal. By using oscilloscope we observed scintillation pulses of a PWO crystal coupled with a photomultiplier tube. Measured spectra were compared with the simulation code of EGS5 to analyze scattering effects. As the result, the pulse amplitudes show good linearity and the pulse shapes are almost constant in the observed energy range.

  3. X-ray studies of krypton, xenon and lead inclusions in aluminium single crystals

    International Nuclear Information System (INIS)

    Grabaek, L.; Bohr, J.; Johnson, E.; Andersen, H.H.; Johansen, A.; Sarholt-Kristensen, L.

    1988-01-01

    Samples of aluminum single crystals with [111] normal were implanted with either Kr, Xe or Pb. The small inclusions formed due to the immiscibility of these elements and aluminum were then studied by X-ray diffraction at various temperatures. The analysis showed that the small noble gas inclusions (≅ 23 A) formed after implantation are solid up to at least 541 Kelvin. During the first heating cycle the inclusions grow and in a second heating cycle it is found that the largest of the inclusions (≅ 42 A) melt below 260 Kelvin. The lead inclusions grow during the first and the second temperature cycle. Gradual melting was observed in a temperature interval from 621-660 Kelvin, which is above 603 Kelvin, the melting temperature of bulk lead. (orig.)

  4. A comparison of single-lead atrial pacing with dual-chamber pacing in sick sinus syndrome

    DEFF Research Database (Denmark)

    Nielsen, Jens Cosedis; Thomsen, Poul Erik B; Højberg, Søren

    2011-01-01

    In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any...

  5. Clinical impact, safety, and efficacy of single- versus Dual-Coil ICD leads in MADIT-CRT

    DEFF Research Database (Denmark)

    Kutyifa, Valentina; Huth Ruwald, Anne Christine; Aktas, Mehmet K.

    2013-01-01

    Current data on efficacy, safety and impact on clinical outcome of single- versus dual-coil implantable cardioverter-defibrillator (ICD) leads are limited and contradictory.......Current data on efficacy, safety and impact on clinical outcome of single- versus dual-coil implantable cardioverter-defibrillator (ICD) leads are limited and contradictory....

  6. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  7. New real-time heartbeat detection method using the angle of a single-lead electrocardiogram.

    Science.gov (United States)

    Song, Mi-Hye; Cho, Sung-Pil; Kim, Wonky; Lee, Kyoung-Joung

    2015-04-01

    This study presents a new real-time heartbeat detection algorithm using the geometric angle between two consecutive samples of single-lead electrocardiogram (ECG) signals. The angle was adopted as a new index representing the slope of ECG signal. The method consists of three steps: elimination of high-frequency noise, calculation of the angle of ECG signal, and detection of R-waves using a simple adaptive thresholding technique. The MIT-BIH arrhythmia database, QT database, European ST-T database, T-wave alternans database and synthesized ECG signals were used to evaluate the performance of the proposed algorithm and compare with the results of other methods suggested in literature. The proposed method shows a high detection rate-99.95% of the sensitivity, 99.95% of the positive predictivity, and 0.10% of the fail detection rate on the four databases. The result shows that the proposed method can yield better or comparable performance than other literature despite the relatively simple process. The proposed algorithm needs only a single-lead ECG, and involves a simple and quick calculation. Moreover, it does not require post-processing to enhance the detection. Thus, it can be effectively applied to various real-time healthcare and medical devices. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. On the residual stress modeling of shot-peened AISI 4340 steel: finite element and response surface methods

    Science.gov (United States)

    Asgari, Ali; Dehestani, Pouya; Poruraminaie, Iman

    2018-02-01

    Shot peening is a well-known process in applying the residual stress on the surface of industrial parts. The induced residual stress improves fatigue life. In this study, the effects of shot peening parameters such as shot diameter, shot speed, friction coefficient, and the number of impacts on the applied residual stress will be evaluated. To assess these parameters effect, firstly the shot peening process has been simulated by finite element method. Then, effects of the process parameters on the residual stress have been evaluated by response surface method as a statistical approach. Finally, a strong model is presented to predict the maximum residual stress induced by shot peening process in AISI 4340 steel. Also, the optimum parameters for the maximum residual stress are achieved. The results indicate that effect of shot diameter on the induced residual stress is increased by increasing the shot speed. Also, enhancing the friction coefficient magnitude always cannot lead to increase in the residual stress.

  9. Remarks on the stabilization of the systems a single unstable leading mode

    International Nuclear Information System (INIS)

    Cotsaftis, M.

    1978-07-01

    Different types of stabilization were proposed for cancelling the plasma motion due to instabilities. The problem of the conventional feedback systems of 'passive' type currently used is rediscussed. The analysis is dealing with the simple case of a plasma with a single leading unstable mode. It is shown that whereas the usual passive feedback cannot achieve a compplete stability on the full interval some other type of more convenient control loops can be used in such a way that the plasma comes back to its original state after a given time, with a power consumption much weaker than in the first case. These properties are also shown to be saved under rather large assumptions in more general situations including the adjunction of delay terms, nonlinear or decoupling terms in the evolution equations of the plasma system [fr

  10. An equivalent dipole analysis of PZT ceramics and lead-free piezoelectric single crystals

    Directory of Open Access Journals (Sweden)

    Andrew J. Bell

    2016-06-01

    Full Text Available The recently proposed Equivalent Dipole Model for describing the electromechanical properties of ionic solids in terms of 3 ions and 2 bonds has been applied to PZT ceramics and lead-free single crystal piezoelectric materials, providing analysis in terms of an effective ionic charge and the asymmetry of the interatomic force constants. For PZT it is shown that, as a function of composition across the morphotropic phase boundary, the dominant bond compliance peaks at 52% ZrO2. The stiffer of the two bonds shows little composition dependence with no anomaly at the phase boundary. The effective charge has a maximum value at 50% ZrO2, decreasing across the phase boundary region, but becoming constant in the rhombohedral phase. The single crystals confirm that both the asymmetry in the force constants and the magnitude of effective charge are equally important in determining the values of the piezoelectric charge coefficient and the electromechanical coupling coefficient. Both are apparently temperature dependent, increasing markedly on approaching the Curie temperature.

  11. An obstructive sleep apnea detection approach using kernel density classification based on single-lead electrocardiogram.

    Science.gov (United States)

    Chen, Lili; Zhang, Xi; Wang, Hui

    2015-05-01

    Obstructive sleep apnea (OSA) is a common sleep disorder that often remains undiagnosed, leading to an increased risk of developing cardiovascular diseases. Polysomnogram (PSG) is currently used as a golden standard for screening OSA. However, because it is time consuming, expensive and causes discomfort, alternative techniques based on a reduced set of physiological signals are proposed to solve this problem. This study proposes a convenient non-parametric kernel density-based approach for detection of OSA using single-lead electrocardiogram (ECG) recordings. Selected physiologically interpretable features are extracted from segmented RR intervals, which are obtained from ECG signals. These features are fed into the kernel density classifier to detect apnea event and bandwidths for density of each class (normal or apnea) are automatically chosen through an iterative bandwidth selection algorithm. To validate the proposed approach, RR intervals are extracted from ECG signals of 35 subjects obtained from a sleep apnea database ( http://physionet.org/cgi-bin/atm/ATM ). The results indicate that the kernel density classifier, with two features for apnea event detection, achieves a mean accuracy of 82.07 %, with mean sensitivity of 83.23 % and mean specificity of 80.24 %. Compared with other existing methods, the proposed kernel density approach achieves a comparably good performance but by using fewer features without significantly losing discriminant power, which indicates that it could be widely used for home-based screening or diagnosis of OSA.

  12. The finite element analysis for prediction of residual stresses induced by shot peening

    International Nuclear Information System (INIS)

    Kim, Cheol; Yang, Won Ho; Sung, Ki Deug; Cho, Myoung Rae; Ko, Myung Hoon

    2000-01-01

    The shot peening is largely used for a surface treatment in which small spherical parts called shots are blasted on a surface of a metallic components with velocities up to 100m/s. This treatment leads to an improvement of fatigue behavior due to the developed compressive residual stresses, and so it has gained widespread acceptance in the automobile and aerospace industries. The residual stress profile on surface layer depends on the parameters of shot peening, which are, shot velocity, shot diameter, coverage, impact angle, material properties etc. and the method to confirm this profile is only measurement by X-ray diffractometer. Despite its importance to automobile and aerospace industries, little attention has been devoted to the accurate modeling of the process. In this paper, the simulation technique is applied to predict the magnitude and distribution of the residual stress and plastic deformation caused by shot peening with the help of the finite element analysis

  13. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  14. Opening Shots and Loose Slots: adapting Las Vegas

    NARCIS (Netherlands)

    Goggin, J.

    2015-01-01

    Anyone who has ever seen a film set in Las Vegas will be familiar with opening shots of sensational neon signage clustered against the night sky. This montage sequence, now an established convention, leads the viewer on a thrilling joy-ride, generally beginning on Fremont Street in the old city

  15. Sleep stage and obstructive apneaic epoch classification using single-lead ECG

    Directory of Open Access Journals (Sweden)

    Yılmaz Bülent

    2010-08-01

    Full Text Available Abstract Background Polysomnography (PSG is used to define physiological sleep and different physiological sleep stages, to assess sleep quality and diagnose many types of sleep disorders such as obstructive sleep apnea. However, PSG requires not only the connection of various sensors and electrodes to the subject but also spending the night in a bed that is different from the subject's own bed. This study is designed to investigate the feasibility of automatic classification of sleep stages and obstructive apneaic epochs using only the features derived from a single-lead electrocardiography (ECG signal. Methods For this purpose, PSG recordings (ECG included were obtained during the night's sleep (mean duration 7 hours of 17 subjects (5 men with ages between 26 and 67. Based on these recordings, sleep experts performed sleep scoring for each subject. This study consisted of the following steps: (1 Visual inspection of ECG data corresponding to each 30-second epoch, and selection of epochs with relatively clean signals, (2 beat-to-beat interval (RR interval computation using an R-peak detection algorithm, (3 feature extraction from RR interval values, and (4 classification of sleep stages (or obstructive apneaic periods using one-versus-rest approach. The features used in the study were the median value, the difference between the 75 and 25 percentile values, and mean absolute deviations of the RR intervals computed for each epoch. The k-nearest-neighbor (kNN, quadratic discriminant analysis (QDA, and support vector machines (SVM methods were used as the classification tools. In the testing procedure 10-fold cross-validation was employed. Results QDA and SVM performed similarly well and significantly better than kNN for both sleep stage and apneaic epoch classification studies. The classification accuracy rates were between 80 and 90% for the stages other than non-rapid-eye-movement stage 2. The accuracies were 60 or 70% for that specific stage

  16. Assembly procedure for Shot Loading Platform

    International Nuclear Information System (INIS)

    Routh, R.D.

    1995-01-01

    This supporting document describes the assembly procedure for the Shot Loading Platform. The Shot Loading Platform is used by multiple equipment removal projects to load shielding shot in the annular spaces of the equipment storage containers. The platform height is adjustable to accommodate different sizes of storage containers and transport assemblies

  17. 7 CFR 51.904 - Shot berries.

    Science.gov (United States)

    2010-01-01

    ... Standards for Grades of Table Grapes (European or Vinifera Type) 1 Definitions § 51.904 Shot berries. Shot berries means very small berries resulting from insufficient pollination, usually seedless in those... 7 Agriculture 2 2010-01-01 2010-01-01 false Shot berries. 51.904 Section 51.904 Agriculture...

  18. 50 CFR 20.134 - Nontoxic shot.

    Science.gov (United States)

    2010-10-01

    ... shot (negative control), or the candidate shot or coated shot. Fluoroscope birds at 1 week after dosage... and 30, collect blood by venipuncture, determine hematocrit, hemoglobin concentration and other.... Provide body weight and blood parameter measurements on samples drawn at 24 hours after dosage and at the...

  19. Single-lead portable ECG devices: Perceptions and clinical accuracy compared to conventional cardiac monitoring.

    Science.gov (United States)

    Mehta, Devin D; Nazir, Noreen T; Trohman, Richard G; Volgman, Annabelle S

    2015-01-01

    Portable ECG devices are widely available yet there are limited data on their accuracy, physician and patient perceptions, and ease of use. The purpose of this study was to evaluate the accuracy of 4 single-lead portable ECG devices compared to a conventional 3-lead hospital cardiac monitor and to assess physician and patient perceptions of portable ECG devices. Twenty consecutive hospitalized patients were provided 4 portable ECG devices for 30 second cardiac rhythm recording. ECG rhythm strips from the portable ECG devices were interpreted by a group of 5 physician reviewers. The reviewers then compared the portable ECG device rhythm strips to simultaneously recorded hospital cardiac monitor rhythm strips to determine physician preference. A cardiac electrophysiologist interpreted ECG rhythm strips from the hospital cardiac monitor as the "gold standard." Rhythm interpretations of the portable ECG devices and the hospital cardiac monitor were analyzed to evaluate clinical accuracy. Patient perceptions were evaluated by a 20-item questionnaire. There was less than 50% concordance of portable ECG device rhythm strips with the hospital cardiac monitor (when uninterpretable rhythm strips were included). Physicians usually preferred interpreting ECGs from hospital cardiac monitors compared to portable ECG devices. Manufacturer instructions were insufficient to allow patients to operate portable ECG devices in a limited time. Most patients felt comfortable using a portable ECG device if prescribed by a physician. Portable ECG devices may be a reasonable option for long-term rhythm surveillance in select patients. Widespread use of these devices cannot be endorsed unless improvements in their accuracy are properly addressed. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Intra-shot MSE Calibration Technique For LHCD Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Jinseok; Scott, Steve; Shiraiwa, Syun' ichi; Greenwald, Martin; Parker, Ronald; Wallace, Gregory

    2009-11-23

    The spurious drift in pitch angle of order several degrees measured by the Motional Stark Effect (MSE) diagnostic in the Alcator C-Mod tokamak1 over the course of an experimental run day has precluded direct utilization of independent absolute calibrations. Recently, the underlying cause of the drift has been identified as thermal stress-induced birefringence in a set of in-vessel lenses. The shot-to-shot drift can be avoided by using MSE to measure only the change in pitch angle between a reference phase and a phase of physical interest within a single plasma discharge. This intra-shot calibration technique has been applied to the Lower Hybrid Current Drive (LHCD) experiments and the measured current profiles qualitatively demonstrate several predictions of LHCD theory such as an inverse dependence of current drive efficiency on the parallel refractive index and the presence of off-axis current drive.

  1. A portable respiratory rate estimation system with a passive single-lead electrocardiogram acquisition module.

    Science.gov (United States)

    Nayan, Nazrul Anuar; Risman, Nur Sabrina; Jaafar, Rosmina

    2016-07-27

    Among vital signs of acutely ill hospital patients, respiratory rate (RR) is a highly accurate predictor of health deterioration. This study proposes a system that consists of a passive and non-invasive single-lead electrocardiogram (ECG) acquisition module and an ECG-derived respiratory (EDR) algorithm in the working prototype of a mobile application. Before estimating RR that produces the EDR rate, ECG signals were evaluated based on the signal quality index (SQI). The SQI algorithm was validated quantitatively using the PhysioNet/Computing in Cardiology Challenge 2011 training data set. The RR extraction algorithm was validated by adopting 40 MIT PhysioNet Multiparameter Intelligent Monitoring in Intensive Care II data set. The estimated RR showed a mean absolute error (MAE) of 1.4 compared with the ``gold standard'' RR. The proposed system was used to record 20 ECGs of healthy subjects and obtained the estimated RR with MAE of 0.7 bpm. Results indicate that the proposed hardware and algorithm could replace the manual counting method, uncomfortable nasal airflow sensor, chest band, and impedance pneumotachography often used in hospitals. The system also takes advantage of the prevalence of smartphone usage and increase the monitoring frequency of the current ECG of patients with critical illnesses.

  2. Rotary peening with captive shot

    International Nuclear Information System (INIS)

    1998-02-01

    Roto Peen with captive shot removes coatings and surface contamination from concrete floors. The objective of treating radioactively contaminated concrete floors during the Deactivation and Decommissioning (D and D) process is to reduce the surface contamination levels to meet regulatory criteria for unrestricted use. The US Department of Energy (DOE) Chicago Operations office and DOE's Federal Energy Technology Center (FETC) jointly sponsored a Large-Scale Demonstration Project (LSDP) at the Chicago Pile-5 Research Reactor (CP-5) at Argonne National Laboratory-East (ANL). The objective of the LSDP is to demonstrate potentially beneficial D and D technologies in comparison with current baseline technologies. As part of the LSDP, roto Peen with captive shot was demonstrated March 17--20, 1997, to treat a 20 x 25 ft area of radioactively contaminated concrete floor on the service level of the CP-5 building

  3. The Problem of Shot Selection in Basketball

    Science.gov (United States)

    Skinner, Brian

    2012-01-01

    In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question “how likely must the shot be to go in before the player should take it?” and I show that this lower cutoff for shot quality depends crucially on the number of shot opportunities remaining (say, before the shot clock expires), with larger demanding that only higher-quality shots should be taken. The function is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA). The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock. PMID:22295109

  4. The problem of shot selection in basketball.

    Directory of Open Access Journals (Sweden)

    Brian Skinner

    Full Text Available In basketball, every time the offense produces a shot opportunity the player with the ball must decide whether the shot is worth taking. In this article, I explore the question of when a team should shoot and when they should pass up the shot by considering a simple theoretical model of the shot selection process, in which the quality of shot opportunities generated by the offense is assumed to fall randomly within a uniform distribution. Within this model I derive an answer to the question "how likely must the shot be to go in before the player should take it?" and I show that this lower cutoff for shot quality f depends crucially on the number n of shot opportunities remaining (say, before the shot clock expires, with larger n demanding that only higher-quality shots should be taken. The function f(n is also derived in the presence of a finite turnover rate and used to predict the shooting rate of an optimal-shooting team as a function of time. The theoretical prediction for the optimal shooting rate is compared to data from the National Basketball Association (NBA. The comparison highlights some limitations of the theoretical model, while also suggesting that NBA teams may be overly reluctant to shoot the ball early in the shot clock.

  5. Electrochemical determination of cadmium and lead on pristine single-walled carbon nanotube electrodes.

    Science.gov (United States)

    Bui, Minh-Phuong Ngoc; Li, Cheng Ai; Han, Kwi Nam; Pham, Xuan-Hung; Seong, Gi Hun

    2012-01-01

    A flexible, transparent, single-walled carbon nanotube (SWCNT) film electrode was prepared by vacuum filtering methods, followed by photolithographic patterning of a photoresist polymer on the SWCNT surface. The morphology of the SWCNT film electrode surface was characterized using a field-emission scanning electron microscope coupled to an energy-dispersive X-ray spectrophotometer. The electrodes were successfully used as a mercury-free electrochemical sensor for individual and simultaneous detection of cadmium (Cd(2+)) and lead (Pb(2+)) in 0.02 M HCl by square-wave stripping voltammetry. Some important operational parameters, including deposition time, deposition potential, square-wave amplitude, and square wave-frequency were optimized for the detection of Cd(2+) and Pb(2+). The newly developed sensor showed good linear behavior in the examined concentration. For individual Cd(2+) and Pb(2+) ion detection, the linear range was found from 0.033 to 0.228 ppm with detection limits of 0.7 ppb (R(2) = 0.985) for Cd(2+) and 0.8 ppb (R(2) = 0.999) for Pb(2+). For simultaneous detection, the linear range was found from 0.033 to 0.280 ppm with a limit of detection of 2.2 ppb (R(2) = 0.976) and 0.6 ppb (R(2) = 0.996) for Cd(2+) and Pb(2+), respectively. SWCNT film electrodes offered favorable reproducibility of ± 5.4% and 4.3% for Cd(2+) and Pb(2+), respectively. The experiments demonstrated the applicability of carbon nanotubes, specifically in the preparation of SWCNT films. The results suggest that the proposed flexible SWCNT film electrodes can be applied as simple, efficient, cost-effective, and/or disposable electrodes for simultaneous detection of heavy metal ions.

  6. [The determination of the distance of a shot from a smooth-bore weapon based on the damages from the action of the wad containers].

    Science.gov (United States)

    Korniiash, V A; Iodes, Iu V; Goloshchapov, I V

    1989-01-01

    Experimental shots from a No. 16 calibre single-barrelled gun using commercial cartridges in the plastic cartridge cases supplied by wad containers with Nos. 1 and 2 shots revealed that lesions that had typical morphologic structure which were characteristic of wad container action were produced at close distances (less than 2 meters). Therefore preliminary experimental shots are necessary before making concrete decisions on characteristic features of an injuring projectile and shot distance.

  7. Spin-dependent shot noise in semiconductor and graphene nanostructures

    Science.gov (United States)

    Dragomirova, Ralitsa L.

    on the shot noise and look for a relationship between the degree of quantum coherence of transported spins and the shot noise of charge currents. This allows us to propose electrical shot noise-based scheme to probe spin as a measurable degree of freedom. Injection of unpolarized charge current through the longitudinal leads of a four-terminal two-dimensional electron gas with the Rashba SO coupling and SO scattering off extrinsic impurities is responsible not only for the pure spin Hall current in the transverse leads, but also for nonequilibrium random time-dependent current fluctuations. We employ the spin-dependent scattering approach in Chapter 6 [3, 5] to analyze the shot noise of transverse pure spin Hall current and zero charge current, or transverse spin current and non-zero charge Hall current, driven by unpolarized or spin-polarized injected longitudinal charge current, respectively. Since any spin-flip acts as an additional source of noise, we argue that these shot noises provide a unique experimental tool to differentiate between intrinsic and extrinsic SO mechanisms underlying the spin Hall effect in paramagnetic devices. Recently graphene---a one-atom-thick crystal of carbon atoms arranged into a honeycomb lattice---has emerged as one of the most promising materials for future nanoelectronic devices. It combines exceptional sample quality and accessibility with the unique possibility to explore quantum electrodynamics phenomena in a condensed matter system since current is carried by massless Dirac fermions behaving as charged neutrinos. Furthermore, special nanostructures derived from graphene, the so called zigzag nanoribbons, favor ferromagnetic ordering along their edges. Recently shot noise measurements have been used to characterize ballistic transport through evanescent states introduced into clean undoped graphene strips by the attached metallic electrodes. We demonstrate in Chapter 7 [4] that this shot noise can be substantially modified in

  8. Semantic Shot Classification in Sports Video

    Science.gov (United States)

    Duan, Ling-Yu; Xu, Min; Tian, Qi

    2003-01-01

    In this paper, we present a unified framework for semantic shot classification in sports videos. Unlike previous approaches, which focus on clustering by aggregating shots with similar low-level features, the proposed scheme makes use of domain knowledge of a specific sport to perform a top-down video shot classification, including identification of video shot classes for each sport, and supervised learning and classification of the given sports video with low-level and middle-level features extracted from the sports video. It is observed that for each sport we can predefine a small number of semantic shot classes, about 5~10, which covers 90~95% of sports broadcasting video. With the supervised learning method, we can map the low-level features to middle-level semantic video shot attributes such as dominant object motion (a player), camera motion patterns, and court shape, etc. On the basis of the appropriate fusion of those middle-level shot classes, we classify video shots into the predefined video shot classes, each of which has a clear semantic meaning. The proposed method has been tested over 4 types of sports videos: tennis, basketball, volleyball and soccer. Good classification accuracy of 85~95% has been achieved. With correctly classified sports video shots, further structural and temporal analysis, such as event detection, video skimming, table of content, etc, will be greatly facilitated.

  9. Determination of strontium and lead isotope ratios of grains using high resolution inductively coupled plasma mass spectrometer with single collector

    International Nuclear Information System (INIS)

    Shinozaki, Miyuki; Ariyama, Kaoru; Kawasaki, Akira; Hirata, Takafumi

    2010-01-01

    A method for determining strontium and lead isotope ratios of grains was developed. The samples investigated in this study were rice, barley and wheat. The samples were digested with nitric acid and hydrogen peroxide, and heated in a heating block. Strontium and lead were separated from the matrix by adding an acid digested solution into a column packed with Sr resin, which has selectivity for the absorption of strontium and lead. Strontium and lead isotope ratios were determined using a high-resolution inductively coupled plasma mass spectrometer (HR-ICP-MS) with a single collector. The intraday relative standard deviations of 87 Sr/ 86 Sr and lead isotope ratios ( 204 Pb/ 206 Pb, 207 Pb/ 206 Pb, 208 Pb/ 206 Pb) by HR-ICP-MS measurements were < 0.06% and around 0.1%, respectively. This method enabled us to determine strontium and lead isotope ratios in two days. (author)

  10. Home monitoring report from a single lead Lumax DX implantable cardioverter defibrillator: New observations in a new system

    Directory of Open Access Journals (Sweden)

    Yuval Konstantino

    2016-06-01

    Full Text Available A 56-year-old man underwent a single lead Lumax 640 DX implantable cardioverter defibrillator implantation for primary prevention of sudden cardiac death. A DX system consists of a single lead, which provides atrial as well as ventricular electrograms, and enhances atrial arrhythmia detection. Three months after the implantation, high-frequency episodes were detected on the far field and the atrial channels, but not on the bipolar right ventricular channel; these were classified as atrial tachycardia. In the present report, we discussed the unusual pattern of the artifacts that was related to an electromagnetic interference detected by the novel DX system.

  11. Brief Report: Pilot Single-Blind Placebo Lead-in Study of Acamprosate in Youth with Autistic Disorder

    Science.gov (United States)

    Erickson, Craig A.; Wink, Logan K.; Early, Maureen C.; Stiegelmeyer, Elizabeth; Mathieu-Frasier, Lauren; Patrick, Vanessa; McDougle, Christopher J.

    2014-01-01

    Rationale: An excitatory/inhibitory (E:I) imbalance marked by enhanced glutamate and deficient gamma-aminobutyric acid (GABA) neurotransmission may contribute to the pathophysiology of autism spectrum disorders (ASD). Objectives: We report on the first single-blind placebo lead-in trial of acamprosate, a drug with putative mechanisms restoring E:I…

  12. Shot peening: theory applications and recent development

    International Nuclear Information System (INIS)

    Zaid, A.I.O.

    1999-01-01

    Shot peening is a surface treatment process by which the surface of an elastic-plastic target material is subjected to multiple impact by spherical shots made of glass or hard steel in a defined and controlled manner. The multiple impact produces a dynamic compressive stress at the surface of the target, thereby effectively improving its mechanical behavior and eliminates cracks and imperfections hence improving the fatigue life and strength. In this paper, the theory and practice of the shot peening process are reviewed. The main parameters involved in the process and their effects on shot peening are presented and discussed which include: shot material, size and geometry, shot pressure and shot velocity, projection angle, exposure time, table rotational speed, standoff distance coverage, saturation and peening intensity. Furthermore, the effect of shot peening on fatigue life and fatigue strength of ferrous and non-ferrous materials together with other different industrial applications of the process are given. Recent developments in utilizing the shot peening process with welded parts and hard chromium plating aiming at improvement of their fatigue strength and their resistance to stress corrosion cracking are also presented and discussed. Finally, future development of the process are outlined and discussed. (author)

  13. Shot noise in radiobiological systems.

    Science.gov (United States)

    Datesman, A

    2016-11-01

    As a model for human tissue, this report considers the rate of free radical generation in a dilute solution of water in which a beta-emitting radionuclide is uniformly dispersed. Each decay dissipates a discrete quantity of energy, creating a large number of free radicals in a short time within a small volume determined by the beta particle range. Representing the instantaneous dissipated power as a train of randomly-spaced pulses, the time-averaged dissipated power p¯ and rate of free radical generation g¯ are derived. The analogous result in the theory of electrical circuits is known as the shot noise theorem. The reference dose of X-rays D ref producing an identical rate of free radical generation and level of oxidative stress is shown a) to increase with the square root of the absorbed dose, D, and b) to be far larger than D. This finding may have important consequences for public health in cases where the level of shot noise exceeds some noise floor corresponding to equilibrium biological processes. An estimate of this noise floor is made using the example of potassium-40, a beta-emitting radioisotope universally present in living tissue. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Lower Extremity Muscle Activity During a Women's Overhand Lacrosse Shot

    Directory of Open Access Journals (Sweden)

    Millard Brianna M.

    2014-07-01

    Full Text Available The purpose of this study was to describe lower extremity muscle activity during the lacrosse shot. Participants (n=5 females, age 22±2 years, body height 162.6±15.2 cm, body mass 63.7±23.6 kg were free from injury and had at least one year of lacrosse experience. The lead leg was instrumented with electromyography (EMG leads to measure muscle activity of the rectus femoris (RF, biceps femoris (BF, tibialis anterior (TA, and medial gastrocnemius (GA. Participants completed five trials of a warm-up speed shot (Slow and a game speed shot (Fast. Video analysis was used to identify the discrete events defining specific movement phases. Full-wave rectified data were averaged per muscle per phase (Crank Back Minor, Crank Back Major, Stick Acceleration, Stick Deceleration. Average EMG per muscle was analyzed using a 4 (Phase x 2 (Speed ANOVA. BF was greater during Fast vs. Slow for all phases (p0.05. RF and GA were each influenced by the interaction of Phase and Speed (p<0.05 with GA being greater during Fast vs. Slow shots during all phases and RF greater during Crank Back Minor and Major as well as Stick Deceleration (p<0.05 but only tended to be greater during Stick Acceleration (p=0.076 for Fast vs. Slow. The greater muscle activity (BF, RF, GA during Fast vs. Slow shots may have been related to a faster approach speed and/or need to create a stiff lower extremity to allow for faster upper extremity movements.

  15. Equilibrium and shot noise in mesoscopic systems

    Energy Technology Data Exchange (ETDEWEB)

    Martin, T.

    1994-10-01

    Within the last decade, there has been a resurgence of interest in the study of noise in Mesoscopic devices, both experimentally and theoretically. Noise in solid state devices can have different origins: there is 1/f noise, which is believed to arise from fluctuations in the resistance of the sample due to the motion of impurities. On top of this contribution is a frequency independent component associated with the stochastic nature of electron transport, which will be the focus of this paper. If the sample considered is small enough that dephasing and inelastic effects can be neglected, equilibrium (thermal) and excess noise can be completely described in terms of the elastic scattering properties of the sample. As mentioned above, noise arises as a consequence of random processes governing the transport of electrons. Here, there are two sources of randomness: first, electrons incident on the sample occupy a given energy state with a probability given by the Fermi-Dirac distribution function. Secondly, electrons can be transmitted across the sample or reflected in the same reservoir where they came from with a probability given by the quantum mechanical transmission/reflection coefficients. Equilibrium noise refers to the case where no bias voltage is applied between the leads connected to the sample, where thermal agitation alone allows the electrons close to the Fermi level to tunnel through the sample. In general, equilibrium noise is related to the conductance of the sample via the Johnson-Nyquist formula. In the presence of a bias, in the classical regime, one expects to recover the full shot noise < {Delta}{sup 2}I >= 2I{Delta}{mu} as was observed a long time ago in vacuum diodes. In the Mesoscopic regime, however, excess noise is reduced below the shot noise level. The author introduces a more intuitive picture, where the current passing through the device is a superposition of pulses, or electron wave packets, which can be transmitted or reflected.

  16. Single-Sided Deafness Leads to Unilateral Aural Preference within an Early Sensitive Period

    Science.gov (United States)

    Kral, Andrej; Hubka, Peter; Heid, Silvia; Tillein, Jochen

    2013-01-01

    Unilateral deafness has a high incidence in children. In addition to children who are born without hearing in one ear, children with bilateral deafness are frequently equipped only with one cochlear implant, leaving the other ear deaf. The present study investigates the effects of such single-sided deafness during development in the congenitally…

  17. Single-coil and dual-coil defibrillator leads and association with clinical outcomes in a complete Danish nationwide ICD cohort

    DEFF Research Database (Denmark)

    Larsen, Jacob M; Hjortshøj, Søren P; Nielsen, Jens C

    2016-01-01

    BACKGROUND: The best choice of defibrillator lead in patients with routine implantable cardioverter-defibrillator (ICD) is not settled. Traditionally, most physicians prefer dual-coil leads but the use of single-coil leads is increasing. OBJECTIVE: The purpose of this study was to compare clinical...... outcomes in patients with single- and dual-coil leads. METHODS: All 4769 Danish patients 18 years or older with first-time ICD implants from 2007 to 2011 were included from the Danish Pacemaker and ICD Register. Defibrillator leads were 38.9% single-coil leads and 61.1% dual-coil leads. The primary end...... point was all-cause mortality. Secondary end points were lowest successful energy at implant defibrillation testing, first shock failure in spontaneous arrhythmias, structural lead failure, and lead extraction outcomes. RESULTS: Single-coil leads were associated with lower all-cause mortality...

  18. SunShot Initiative Portfolio Book 2014

    Energy Technology Data Exchange (ETDEWEB)

    Solar Energy Technologies Office

    2014-05-01

    The 2014 SunShot Initiative Portfolio Book outlines the progress towards the goals outlined in the SunShot Vision Study. Contents include overviews of each of SunShot’s five subprogram areas, as well as a description of every active project in the SunShot’s project portfolio as of May 2014.

  19. A review on the basketball jump shot.

    Science.gov (United States)

    Okazaki, Victor H A; Rodacki, André L F; Satern, Miriam N

    2015-06-01

    The ability to shoot an effective jump shot in the sport of basketball is critical to a player's success. In an attempt to better understand the aspects related to expert performance, researchers have investigated successful free throws and jump shots of various basketball players and identified movement variables that contribute to their success. The purpose of this study was to complete a systematic review of the scientific literature on the basketball free throw and jump shot for the purpose of revealing the critical components of shooting that coaches, teachers, and players should focus on when teaching, learning, practising, and performing a jump shot. The results of this review are presented in three sections: (a) variables that affect ball trajectory, (b) phases of the jump shot, and (c) additional variables that influence shooting.

  20. Growth and optical properties of RE-doped ternary rubidium lead chloride single crystals

    Czech Academy of Sciences Publication Activity Database

    Král, Robert; Nitsch, Karel; Babin, Vladimir; Šulc, J.; Jelínková, H.; Yokota, Y.; Yoshikawa, A.; Nikl, Martin

    2013-01-01

    Roč. 36, č. 2 (2013), s. 214-220 ISSN 0925- 3467 R&D Projects: GA MŠk LH12150 Institutional support: RVO:68378271 Keywords : rubidium lead chloride * crystal growth * micro-pulling-down method * rare earth doping * luminescence Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.075, year: 2013 http://www.sciencedirect.com/science/article/pii/S0925346713004710

  1. Surface Electronic Structure of Hybrid Organo Lead Bromide Perovskite Single Crystals

    KAUST Repository

    Komesu, Takashi

    2016-08-24

    The electronic structure and band dispersion of methylammonium lead bromide, CH3NH3PbBr3, has been investigated through a combination of angle-resolved photoemission spectroscopy (ARPES) and inverse photoemission spectroscopy (IPES), as well as theoretical modeling based on density functional theory. The experimental band structures are consistent with the density functional calculations. The results demonstrate the presence of a dispersive valence band in MAPbBr3 that peaks at the M point of the surface Brillouin zone. The results also indicate that the surface termination of the CH3NH3PbBr3 is the methylammonium bromide (CH3NH3Br) layer. We find our results support models that predict a heavier hole effective mass in the region of -0.23 to -0.26 me, along the Γ (surface Brillouin center) to M point of the surface Brillouin zone. The surface appears to be n-type as a result of an excess of lead in the surface region. © 2016 American Chemical Society.

  2. Basketball shot types and shot success in different levels of competitive basketball.

    Directory of Open Access Journals (Sweden)

    Frane Erčulj

    Full Text Available The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in, some details about their technical execution (one-legged, two-legged, drive, cut, …, and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA, Euroleague, Slovenian 1st Division, and two Youth basketball competitions. Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition. Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions.

  3. Basketball Shot Types and Shot Success in Different Levels of Competitive Basketball

    Science.gov (United States)

    2015-01-01

    The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in), some details about their technical execution (one-legged, two-legged, drive, cut, …), and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA), Euroleague, Slovenian 1st Division, and two Youth basketball competitions). Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition). Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions. PMID:26038836

  4. Basketball shot types and shot success in different levels of competitive basketball.

    Science.gov (United States)

    Erčulj, Frane; Štrumbelj, Erik

    2015-01-01

    The purpose of our research was to investigate the relative frequencies of different types of basketball shots (above head, hook shot, layup, dunk, tip-in), some details about their technical execution (one-legged, two-legged, drive, cut, …), and shot success in different levels of basketball competitions. We analysed video footage and categorized 5024 basketball shots from 40 basketball games and 5 different levels of competitive basketball (National Basketball Association (NBA), Euroleague, Slovenian 1st Division, and two Youth basketball competitions). Statistical analysis with hierarchical multinomial logistic regression models reveals that there are substantial differences between competitions. However, most differences decrease or disappear entirely after we adjust for differences in situations that arise in different competitions (shot location, player type, and attacks in transition). Differences after adjustment are mostly between the Senior and Youth competitions: more shots executed jumping or standing on one leg, more uncategorised shot types, and more dribbling or cutting to the basket in the Youth competitions, which can all be attributed to lesser technical and physical ability of developing basketball players. The two discernible differences within the Senior competitions are that, in the NBA, dunks are more frequent and hook shots are less frequent compared to European basketball, which can be attributed to better athleticism of NBA players. The effect situational variables have on shot types and shot success are found to be very similar for all competitions.

  5. Effect of Shot Peening in Different Shot Distance and Shot Angle on Surface Morphology, Surface Roughness and Surface Hardness of 316L Biomaterial

    Science.gov (United States)

    Umbu Kondi Maliwemu, Erich; Malau, Viktor; Iswanto, Priyo Tri

    2018-01-01

    Shot peening is a mechanical surface treatment with a beneficial effect to generate compressive residual stress caused by plastic deformation on the surface of material. This plastic deformation can improve the surface characteristics of metallic materials, such as modification of surface morphology, surface roughness, and surface hardness. The objective of this study is to investigate the effect of shot peening in different shot distance and shot angle on surface morphology, surface roughness, and surface hardness of 316L biomaterial. Shot distance was varied at 6, 8, 10, and 12 cm and shot angle at 30, 60, and 90°, working pressure at 7 kg/cm2, shot duration for 20 minutes, and using steel balls S-170 with diameter of 0.6 mm. The results present that the shot distance and shot angle of shot peening give the significant effect to improve the surface morphology, surface roughness, and surface hardness of 316 L biomaterial. Shot peening can increase the surface roughness by the increasing of shot distance and by the decreasing of shot angle. The nearest shot distance (6 cm) and the largest shot angle (90°) give the best results on the grain refinement with the surface roughness of 1.04 μm and surface hardness of 534 kg/mm2.

  6. Practical and social barriers to switching from lead to non-toxic gunshot

    DEFF Research Database (Denmark)

    Kanstrup, Niels

    2015-01-01

    targeted at sea ducks. In Denmark, the use of lead shot was first regulated in 1985 by setting up a ban on inter alia the use of lead shot for hunting in 26 wetlands designated as Ramsar-sites and for clay pigeon shooting in certain areas. Denmark enforced a total ban on the use of lead shot in 1993 in all...

  7. Shot peening speed measurements using lidar technology

    DEFF Research Database (Denmark)

    Angelou, Nikolas; Zhang, Xiaodan; Sjöholm, Mikael

    The shot peening technique is used for the surface modification of metallic components that are part of wind turbines, such as gears, bolts and blade coatings to prevent erosion. An important parameter of this technique is the dynamic energy of emitted shots. In this context the objective...... of this project is to present a proof of concept measurement method for the evaluation of the speed of the shots. A remote sensing laser anemometer was selected as a probing instrument of the peening shots’ speed since it avoids any disturbances to the flow from the presence of an in-situ instrument. Furthermore...

  8. A QRS Detection and R Point Recognition Method for Wearable Single-Lead ECG Devices.

    Science.gov (United States)

    Chen, Chieh-Li; Chuang, Chun-Te

    2017-08-26

    In the new-generation wearable Electrocardiogram (ECG) system, signal processing with low power consumption is required to transmit data when detecting dangerous rhythms and to record signals when detecting abnormal rhythms. The QRS complex is a combination of three of the graphic deflection seen on a typical ECG. This study proposes a real-time QRS detection and R point recognition method with low computational complexity while maintaining a high accuracy. The enhancement of QRS segments and restraining of P and T waves are carried out by the proposed ECG signal transformation, which also leads to the elimination of baseline wandering. In this study, the QRS fiducial point is determined based on the detected crests and troughs of the transformed signal. Subsequently, the R point can be recognized based on four QRS waveform templates and preliminary heart rhythm classification can be also achieved at the same time. The performance of the proposed approach is demonstrated using the benchmark of the MIT-BIH Arrhythmia Database, where the QRS detected sensitivity (Se) and positive prediction (+P) are 99.82% and 99.81%, respectively. The result reveals the approach's advantage of low computational complexity, as well as the feasibility of the real-time application on a mobile phone and an embedded system.

  9. Between Shots TRANSP Web Service

    Science.gov (United States)

    Feibush, E.; Andre, R.; Ludescher-Furth, C.; Kaye, S.; McCune, D.

    2008-11-01

    Running TRANSP between NSTX shots requires rapid data preparation and job submittal. A web service with a graphical user interface and data visualization has been developed to meet these goals. The underlying data preparation system has a command line interface written in Python and runs on a PPPL compute server. The display client is a Java program (ElVis) that sends requests to the data preparation system. As the run data is prepared, graphs are created and sent to the client for display. Flux surface plots are displayed and animated over time. The most commonly used control options are implemented in the UI as buttons and text fields. A time slice or time dependent run can be prepared. The command line interface is available in the client program for expert users to apply advanced settings, to prototype new UI buttons, and to run scripts. The client program contains a simple text editor for modifying the TRANSP namelist. When data preparation is complete the run is submitted to the TRANSP production system. The initial version has been deployed and is being tested in the control room setting. Results will be discussed in the poster presentation. Work performed at PPPL under the auspices of U.S. DOE Contract DE-AC02-76CH03073.

  10. Shot noise and electronic properties in the inversion-symmetric Weyl semimetal resonant structure

    Science.gov (United States)

    Yang, Yanling; Bai, Chunxu; Xu, Xiaoguang; Jiang, Yong

    2018-02-01

    Using the transfer matrix method, the authors combine the analytical formula with numerical calculation to explore the shot noise and conductance of massless Weyl fermions in the Weyl semimetal resonant junction. By varying the barrier strength, the structure of the junction, the Fermi energy, and the crystallographic angle, the shot noise and conductance can be tuned efficiently. For a quasiperiodic superlattice, in complete contrast to the conventional junction case, the effect of the disorder strength on the shot noise and conductance depends on the competition of classical tunneling and Klein tunneling. Moreover, the delta barrier structure is also vital in determining the shot noise and conductance. In particular, a universal Fano factor has been found in a single delta potential case, whereas the resonant structure of the Fano factor perfectly matches with the number of barriers in a delta potential superlattice. These results are crucial for engineering nanoelectronic devices based on this topological semimetal material.

  11. A lightweight QRS detector for single lead ECG signals using a max-min difference algorithm.

    Science.gov (United States)

    Pandit, Diptangshu; Zhang, Li; Liu, Chengyu; Chattopadhyay, Samiran; Aslam, Nauman; Lim, Chee Peng

    2017-06-01

    Detection of the R-peak pertaining to the QRS complex of an ECG signal plays an important role for the diagnosis of a patient's heart condition. To accurately identify the QRS locations from the acquired raw ECG signals, we need to handle a number of challenges, which include noise, baseline wander, varying peak amplitudes, and signal abnormality. This research aims to address these challenges by developing an efficient lightweight algorithm for QRS (i.e., R-peak) detection from raw ECG signals. A lightweight real-time sliding window-based Max-Min Difference (MMD) algorithm for QRS detection from Lead II ECG signals is proposed. Targeting to achieve the best trade-off between computational efficiency and detection accuracy, the proposed algorithm consists of five key steps for QRS detection, namely, baseline correction, MMD curve generation, dynamic threshold computation, R-peak detection, and error correction. Five annotated databases from Physionet are used for evaluating the proposed algorithm in R-peak detection. Integrated with a feature extraction technique and a neural network classifier, the proposed ORS detection algorithm has also been extended to undertake normal and abnormal heartbeat detection from ECG signals. The proposed algorithm exhibits a high degree of robustness in QRS detection and achieves an average sensitivity of 99.62% and an average positive predictivity of 99.67%. Its performance compares favorably with those from the existing state-of-the-art models reported in the literature. In regards to normal and abnormal heartbeat detection, the proposed QRS detection algorithm in combination with the feature extraction technique and neural network classifier achieves an overall accuracy rate of 93.44% based on an empirical evaluation using the MIT-BIH Arrhythmia data set with 10-fold cross validation. In comparison with other related studies, the proposed algorithm offers a lightweight adaptive alternative for R-peak detection with good

  12. Growth and characterization of lead-free (K,Na)NbO3-based piezoelectric single crystals

    International Nuclear Information System (INIS)

    Liu, Hairui

    2016-01-01

    Lead-free piezoelectric materials have received increasing attention in the last decade, driven by environmental issues and health concerns. Of considerable interest is the (K,Na)NbO 3 (KNN)-based system, which possesses a relatively high Curie temperature and good piezoelectric properties. Abundant publications on KNN-based polycrystalline ceramics increased the interest in studying their single-crystalline form, based on two major concerns. The first concern refers to the negative role of grain interactions on the electromechanical response. The second concern deals with domain engineering. The relationship between external electric field direction, crystallographic orientation, and spontaneous polarization vectors for a specific structure can be more readily established in single crystals and thus offers a pathway for an in-depth understanding of fundamental mechanism and potential applications. The exciting enhancement of both piezoelectric and ferroelectric response in lead-based single crystals also encourages the further exploration of KNN-based piezoelectric crystals, as they possess the same perovskite structure. The main goal of this thesis is to find possible approaches for improved electromechanical properties in KNN-based piezoelectric single crystals. In Chapter 2, the current development of KNN-based single crystals as piezoelectrics is reviewed, following a short introduction of fundamental knowledge on piezoelectrics and ferroelectrics. Both submerged-seed solution growth and top-seeded solution growth techniques were employed to produce single crystals, as described detailed in Chapter 3. Emphasis is subsequently placed on issues of the crystal growth process, effective methods to enhance electrical properties, and crystallographic orientation-dependent electrical properties in Li-, Ta-, and/or Sb-substituted KNN single crystals. The main conclusions from the crystal growth aspect are presented in Chapter 4 and can be summarized as follows: (i

  13. Pregnant Women Need a Flu Shot

    Science.gov (United States)

    Pregnant? You Need a Flu Shot! Information for pregnant women Because you are pregnant, CDC and your ob- ... more likely to get severely ill from flu. Pregnant women who get flu are at high risk of ...

  14. Separation of Lead (Pb2+ and Cadmium (Cd2+ from Single and Binary Salt Aqueous Solutions Using Nanofiltration Membranes

    Directory of Open Access Journals (Sweden)

    Ahmed Abed Mohammed

    2016-04-01

    Full Text Available The present work reports on the performance of three types of nanofiltration membranes in the removal of highly polluting and toxic lead (Pb2+ and cadmium (Cd2+ from single and binary salt aqueous solutions simulating real wastewaters. The effect of the operating variables (pH (5.5-6.5, types of NF membrane and initial ions concentration (10-250 ppm on the separation process and water flux was investigated. It was observed that the rejection efficiency increased with increasing pH of solution and decreasing the initial metal ions concentrations. While the flux decreased with increasing pH of solution and increasing initial metal ions concentrations. The maximum rejection of lead and cadmium ions in single salt solution was 99%, 97.5 % and 98 % at pH 6, 6.5 and 6.2 and 78%, 49.2% and 44% at pH 6.5, 6.2 and 6.5 for NF1, NF2 and NF3 respectively. On the other hand, maximum permeate flux for single NF2 (32.2> NF3 (16.1>NF1 (14.2 (l/m2.h for 100 ppm, higher than binary salt solution was NF2 (23.7 ˃ NF3 (13 ˃ NF1 (8 (l/m2.h for (10 Pb2+/50 Cd2+ ppm. The NF membranes proved able to achieve high separation efficiency of both lead and cadmium ions in very suitable conditions, leaving wastewaters in a condition suitable prior discharged into the environment.

  15. Discharge mechanisms and electrochemical impedance spectroscopy measurements of single negative and positive lead-acid battery plates

    Energy Technology Data Exchange (ETDEWEB)

    D' Alkaine, C.V. [Group of Electrochemistry and Polymers, Chemistry Department, Federal University of Sao Carlos, 13560-905 Sao Carlos, SP (Brazil); Mengarda, P.; Impinnisi, P.R. [Battery Laboratory, Institute of Technology for Development - LACTEC, Curitiba, PR (Brazil)

    2009-06-01

    This study interpreted open circuit impedance measurements of single negative and positive lead-acid battery plates, which were at different discharge levels and arranged in a four-electrode cell. This was performed in the framework of a proposed general model of charge/discharge reactions, morphological models of active materials, and based on interpretation of the characteristics of single negative and positive plates as measured by electrochemical impedance spectroscopy (EIS). This study shows that the proposed reaction models, morphological characteristics and EIS attributions are compatible with the obtained EIS data. The analysis indicates that negative and positive plate reaction mechanisms cannot be those proposed by the dissolution-precipitation mechanism alone. Rather, the reactions seem to obey the various mechanisms and morphologic ideas proposed in the present paper. It is shown that variations in the resistivity and dielectric constants of discharged films need to be studied in greater detail than film thicknesses to gain a better understanding of the processes. (author)

  16. Loss of a single allele for Ku80 leads to progenitor dysfunction and accelerated aging in skeletal muscle

    Science.gov (United States)

    Didier, Nathalie; Hourdé, Christophe; Amthor, Helge; Marazzi, Giovanna; Sassoon, David

    2012-01-01

    Muscle wasting is a major cause of morbidity in the elderly. Ku80 is required for DNA double strand repair and is implicated in telomere maintenance. Complete loss-of-function leads to reduced post-natal growth and severe progeria in mice. We examined the role of Ku80 in age-related skeletal muscle atrophy. While complete loss of Ku80 leads to pronounced aging in muscle as expected, accompanied by accumulation of DNA damage, loss of a single allele is sufficient to accelerate aging in skeletal muscle although post-natal growth is normal. Ku80 heterozygous muscle shows no DNA damage accumulation but undergoes premature telomere shortening that alters stem cell self-renewal through stress response pathways including p53. These data reveal an unexpected requirement for both Ku80 alleles for optimal progenitor function and prevention of early onset aging in muscle, as well as providing a useful model for therapeutic approaches. PMID:22915554

  17. A common single nucleotide polymorphism can exacerbate long-QT type 2 syndrome leading to sudden infant death

    DEFF Research Database (Denmark)

    Nof, Eyal; Cordeiro, Jonathan M; Pérez, Guillermo J

    2010-01-01

    and mutation expressed singly and in combination in Chinese ovary (CHO-K1) and COS-1 cells. An asymptomatic woman presenting after the death of her 2-day-old infant and spontaneous abortion of a second baby in the first trimester was referred for genetic analysis. The newborn infant had nearly incessant...... suggest that a common polymorphism (K897T) can markedly accentuate the loss of function of mildly defective HERG channels, leading to long-QT syndrome-mediated arrhythmias and sudden infant death....

  18. Vaccine shot-limiting: Estimating the prevalence, indicators, and impact on vaccination status - Michigan, 2012.

    Science.gov (United States)

    Weinberg, Meghan; Dietz, Stephanie; Potter, Rachel; Swanson, Robert; Miller, Corinne; McFadden, Jevon

    2017-02-15

    Concerns regarding vaccine safety and pain have prompted certain parents to limit the number of shots their child receives per visit. We estimated the prevalence of shot-limited children in Michigan, described their characteristics, assessed whether shot-limited children were up-to-date on recommended vaccinations, and investigated possible intervention points for vaccination education. We analyzed vaccination registry and birth record data of children born in Michigan during 2012 who had ⩾2 vaccination visits, with ⩾1 visits after age 5months. Shot-limited was defined as receiving ⩽2 shots at all visits through age 24months. Nonlimited children received >2 shots at ⩾1 visits. Up-to-date vaccination was based on receipt of a seven-vaccine series and was determined at ages 24months and 35months. Risk ratios (RR) were calculated using risk regression. Of 101,443 children, a total of 2,967 (3%) children were shot-limited. Mothers of shot-limited children were more likely to be white (RR: 1.2; 95% confidence interval [CI]: 1.2-1.2), college graduate (RR: 1.9; 95% CI: 1.9-2.0), and married (RR: 1.5; 95% CI: 1.5-1.5). Compared with nonlimited children, shot-limited children were more likely to be born in a nonhospital setting (RR: 11.7; 95% CI: 9.4-14.6) and have a midwife attendant (RR: 1.9; 95% CI: 1.7-2.1). Shot-limited children were less likely to be up-to-date on recommended vaccinations (RR: 0.2; 95% CI: 0.2-0.3); this association was stronger for those with a midwife birth attendant (RR: 0.1; 95% CI: 0.1-0.2) rather than a medical doctor (RR: 0.3; 95% CI: 0.2-0.3). Shot-limited children are less likely to be up-to-date on vaccinations, possibly leading to increased risk for vaccine-preventable diseases. This association was stronger for those with a midwife birth attendant. This analysis should prompt targeted education, such as to midwives, concerning risks associated with shot-limiting behavior. Published by Elsevier Ltd.

  19. Light field driven streak-camera for single-shot measurements of the temporal profile of XUV-pulses from a free-electron laser; Lichtfeld getriebene Streak-Kamera zur Einzelschuss Zeitstrukturmessung der XUV-Pulse eines Freie-Elektronen Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Fruehling, Ulrike

    2009-10-15

    The Free Electron Laser in Hamburg (FLASH) is a source for highly intense ultra short extreme ultraviolet (XUV) light pulses with pulse durations of a few femtoseconds. Due to the stochastic nature of the light generation scheme based on self amplified spontaneous emission (SASE), the duration and temporal profile of the XUV pulses fluctuate from shot to shot. In this thesis, a THz-field driven streak-camera capable of single pulse measurements of the XUV pulse-profile has been realized. In a first XUV-THz pump-probe experiment at FLASH, the XUV-pulses are overlapped in a gas target with synchronized THz-pulses generated by a new THz-undulator. The electromagnetic field of the THz light accelerates photoelectrons produced by the XUV-pulses with the resulting change of the photoelectron momenta depending on the phase of the THz field at the time of ionisation. This technique is intensively used in attosecond metrology where near infrared streaking fields are employed for the temporal characterisation of attosecond XUV-Pulses. Here, it is adapted for the analysis of pulse durations in the few femtosecond range by choosing a hundred times longer far infrared streaking wavelengths. Thus, the gap between conventional streak cameras with typical resolutions of hundreds of femtoseconds and techniques with attosecond resolution is filled. Using the THz-streak camera, the time dependent electric field of the THz-pulses was sampled in great detail while on the other hand the duration and even details of the time structure of the XUV-pulses were characterized. (orig.)

  20. Growth and characterization of undoped and Mn doped lead-free piezoelectric NBT–KBT single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Babu, G. Anandha, E-mail: anandcgc@gmail.com [Centre for Crystal Growth, SSN College of Engineering, Kalavakkam 603 110 (India); Subramaniyan, Raja R. [Centre for Crystal Growth, SSN College of Engineering, Kalavakkam 603 110 (India); Bhaumik, Indranil [Laser Materials Development and Devices Division, Raja Ramanna Centre for Advanced Technology, Indore 452 013 (India); Ganesamoorthy, S. [X-ray Scattering and Crystal Growth Section, Condensed Matter Physics Division, Materials Science Group, IGCAR, Kalpakkam 603102 (India); Ramasamy, P. [Centre for Crystal Growth, SSN College of Engineering, Kalavakkam 603 110 (India); Gupta, P.K. [Laser Materials Development and Devices Division, Raja Ramanna Centre for Advanced Technology, Indore 452 013 (India)

    2014-05-01

    Highlights: • Single crystals of undoped and Mn doped NKBT crystals are grown by spontaneous nucleation. • Temperature and frequency dependent dielectric constant and loss are measured. • Dielectric constant has increased and the loss has reduced on Mn doped NKBT. • Concentration of oxygen vacancies has been reduced in Mn doped NKBT. • The activation energy for undoped and Mn doped NKBT are calculated. - Abstract: Lead-free piezoelectric single crystals of undoped and 1 wt% Mn doped 0.80 Na{sub 0.5}Bi{sub 0.5}TiO{sub 3}–0.20 K{sub 0.5}Bi{sub 0.5}TiO{sub 3} (NKBT) was grown using self-flux. Powder X-ray diffraction analysis revealed that the grown crystals belong to tetragonal system at room temperature. The lattice strain was calculated from Williamson Hall relation for undoped and Mn doped NKBT crystals. A significant change is observed in dielectric behavior of Mn doped NKBT when compared to undoped sample. The diffuseness increased substantially on Mn doped NKBT which masked the ferroelectric to antiferroelectric transition in the dielectric constant plot. The AC impedance study revealed that the conduction is governed by the singly ionized oxygen vacancy. Further, the decrease in the conductivity on Mn doping suggests that Mn replaces the Bi vacancy, which reduces the oxygen vacancy.

  1. Indirect monitoring shot-to-shot shock waves strength reproducibility during pump–probe experiments

    Energy Technology Data Exchange (ETDEWEB)

    Pikuz, T. A., E-mail: tatiana.pikuz@eie.eng.osaka-u.ac.jp [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 Japan (Japan); Photon Pioneers Center, Osaka University, Suita, Osaka 565-0871 Japan (Japan); Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412 (Russian Federation); Faenov, A. Ya. [Joint Institute for High Temperatures, Russian Academy of Sciences, Moscow 125412 (Russian Federation); Institute for Academic Initiatives, Osaka University, Suita, Osaka 565-0871 (Japan); Ozaki, N.; Habara, H.; Tanaka, K. A.; Kodama, R. [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 Japan (Japan); Photon Pioneers Center, Osaka University, Suita, Osaka 565-0871 Japan (Japan); Hartley, N. J.; Matsuoka, T. [Institute for Academic Initiatives, Osaka University, Suita, Osaka 565-0871 (Japan); Albertazzi, B.; Matsuyama, S.; Yamauchi, K.; Ochante, R. [Graduate School of Engineering, Osaka University, Suita, Osaka 565-0871 Japan (Japan); Takahashi, K.; Sueda, K. [Photon Pioneers Center, Osaka University, Suita, Osaka 565-0871 Japan (Japan); Tange, Y. [Japan Synchrotron Radiation Research Institute, Sayo, Hyogo 679-5198 (Japan); Sakata, O. [Synchrotron X-ray Station at SPring-8, NIMS, Sayo, Hyogo 679-5148 (Japan); Sekine, T.; Sato, T.; Umeda, Y. [Graduate School of Science, Hiroshima University, Higashi-Hiroshima 739-8526 (Japan); Inubushi, Y. [Japan Synchrotron Radiation Research Institute, Sayo, Hyogo 679-5198 (Japan); RIKEN Spring-8 Center, Sayo, Hyogo 679-5148 Japan (Japan); and others

    2016-07-21

    We present an indirect method of estimating the strength of a shock wave, allowing on line monitoring of its reproducibility in each laser shot. This method is based on a shot-to-shot measurement of the X-ray emission from the ablated plasma by a high resolution, spatially resolved focusing spectrometer. An optical pump laser with energy of 1.0 J and pulse duration of ∼660 ps was used to irradiate solid targets or foils with various thicknesses containing Oxygen, Aluminum, Iron, and Tantalum. The high sensitivity and resolving power of the X-ray spectrometer allowed spectra to be obtained on each laser shot and to control fluctuations of the spectral intensity emitted by different plasmas with an accuracy of ∼2%, implying an accuracy in the derived electron plasma temperature of 5%–10% in pump–probe high energy density science experiments. At nano- and sub-nanosecond duration of laser pulse with relatively low laser intensities and ratio Z/A ∼ 0.5, the electron temperature follows T{sub e} ∼ I{sub las}{sup 2/3}. Thus, measurements of the electron plasma temperature allow indirect estimation of the laser flux on the target and control its shot-to-shot fluctuation. Knowing the laser flux intensity and its fluctuation gives us the possibility of monitoring shot-to-shot reproducibility of shock wave strength generation with high accuracy.

  2. Measurement of the lidar signal fluctuation with a shot-per-shot instrument.

    Science.gov (United States)

    Durieux, E; Fiorani, L

    1998-10-20

    A measurement of the signal noise was carried out with a shot-per-shot lidar. This system was operated in the UV spectral region for ozone profiling in the low troposphere. We report on important discrepancies between our results and the estimations based on the assumptions commonly supporting the numerical modeling of lidar experiments.

  3. Microscopic analysis of effect of shot peening on corrosion fatigue behavior of aluminum alloy

    International Nuclear Information System (INIS)

    Kim, Jong Cheon; Cheong, Seong Kyun

    2012-01-01

    The object of this study considers corrosion fatigue improvement of 7075-T6 aluminum by using shot peening treatment on 3.5% NaCl solution at room temperature. Aluminum alloy is generally used in aerospace structural components because of the light weight and high strength characteristics. Many studies have shown that an aluminum alloy can be approximately 50% lighter than other materials. Mostly, corrosion leads to earlier fatigue crack propagation under tensile conditions and severely reduces the life of structures. Therefore, the technique to improve material resistance to corrosion fatigue is required. Shot peening technology is widely used to improve fatigue life and other mechanical properties by induced compressive residual stress. Even the roughness of treated surface causes pitting corrosion, the compressive residual stress, which is induced under the surface layer of material by shot peening, suppersses the corrosion and increases the corrosion resistance. The experimental results for shot peened specimens were compared with previous work for non treated aluminum alloy. The results show that the shot peening treatment affects the corrosion fatigue improvement of aluminum alloys and the induced compressive residual stress by shot peening treatment improves the resistance to corrosion fatigue

  4. Shot-to-shot comparison of the first Li-beam-driven hohlraum experiments

    International Nuclear Information System (INIS)

    Derzon, M.S.; Rochau, G.E.; Chandler, G.A.; Moats, A.R.; Leeper, R.J.

    1995-01-01

    Shot-to-shot comparison of the first Li-beam hohlraum experiments on PBFA II provides an opportunity to measure and determine the factor that affect the on-axis reproducibility of the Li-ion beam. Both inner-shell and thermal x-ray emission are used to estimate the relative beam power on target from shot to shot. The M- and L-shell Au x-ray yield measurements were made with an array of 11 filtered p-i-n detectors, and the thermal emission measurements were made with an array of three filtered bolometers. The analysis shows that the beam intensity on target varied by more than a factor of 10 during the shot series. By correlating the results of the beam on target with other diagnostics and events, we have identified some potential causes for these variations

  5. X-ray emission from z pinches at 107 A: Current scaling, gap closure, and shot-to-shot fluctuations

    International Nuclear Information System (INIS)

    Stygar, W.A.; Ives, H.C.; Fehl, D.L.; Cuneo, M.E.; Mazarakis, M.G.; Bailey, J.E.; Bennett, G.R.; Bliss, D.E.; Chandler, G.A.; Leeper, R.J.; Matzen, M.K.; McDaniel, D.H.; McGurn, J.S.; McKenney, J.L.; Mix, L.P.; Muron, D.J.; Porter, J.L.; Ramirez, J.J.; Ruggles, L.E.; Seamen, J.F.

    2004-01-01

    a single pinch would have on the shot-success probability of the double-pinch inertial-confinement-fusion driver proposed by Hammer et al. [Phys. Plasmas 6, 2129 (1999)]. We find that on a given shot, the probability that two independent pinches would radiate the same peak power to within a factor of 1±α (where 0≤α 1/2 )%=8.5% fluctuation in P r would provide adequate symmetry on 44% of the shots. We propose that three-dimensional radiative-magnetohydrodynamic simulations be performed to quantify the sensitivity of the x-ray emission to various initial conditions, and to determine whether an imploding z pinch is a spatiotemporal chaotic system

  6. Laser conditioning and multi-shot laser damage accumulation effects of HfO2/SiO2 antireflective coatings

    International Nuclear Information System (INIS)

    Zhao Yuanan; Wang Tao; Zhang Dawei; Shao Jianda; Fan Zhengxiu

    2005-01-01

    Laser conditioning effects of the HfO 2 /SiO 2 antireflective (AR) coatings at 1064 nm and the accumulation effects of multi-shot laser radiation were investigated. The HfO 2 /SiO 2 AR coatings were prepared by E-beam evaporation (EBE). The single-shot and multi-shot laser induced damage threshold was detected following ISO standard 11254-1.2, and the laser conditioning was conducted by three-step raster scanning method. It was found that the single-shot LIDT and multi-shot LIDT was almost the same. The damage mostly >80% occurred in the first shot under multi-shot laser radiation, and after that the damage occurring probability plummeted to <5%. There was no obvious enhancement of the laser damage resistance for both the single-shot and multi-shot laser radiation of the AR coatings after laser conditioning. A Nomarski microscope was employed to map the damage morphology, and it found that the damage behavior is defect-initiated for both unconditioned and conditioned samples

  7. 3-lead acquisition using single channel ECG device developed on AD8232 analog front end for wireless ECG application

    Science.gov (United States)

    Agung, Mochammad Anugrah; Basari

    2017-02-01

    Electrocardiogram (ECG) devices measure electrical activity of the heart muscle to determine heart conditions. ECG signal quality is the key factor in determining the diseases of the heart. This paper presents the design of 3-lead acquistion on single channel wireless ECG device developed on AD8232 chip platform using microcontroller. To make the system different from others, monopole antenna 2.4 GHz is used in order to send and receive ECG signal. The results show that the system still can receive ECG signal up to 15 meters by line of sight (LOS) condition. The shape of ECG signals is precisely similar with the expected signal, although some delays occur between two consecutive pulses. For further step, the system will be applied with on-body antenna in order to investigate body to body communication that will give variation in connectivity from the others.

  8. SunShot Initiative Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    DOE Solar Energy Technologies Office

    2015-04-01

    The U.S. Department of Energy (DOE) SunShot Initiative is a collaborative national effort launched in 2011 that aggressively drives innovation to make solar energy fully cost competitive with traditional energy sources before the end of the decade. The SunShot fact sheet outlines goals and successes of the program as it works with private companies, universities, non-profit organizations, state and local governments, and national laboratories to drive down the cost of solar electricity to $0.06 per kilowatt-hour, without incentives, by the year 2020.

  9. Sport video shot segmentation and classification

    Science.gov (United States)

    Dahyot, Rozenn; Rea, Niall; Kokaram, Anil C.

    2003-06-01

    This paper considers the statistics of local appearance based measures that are suitable for the visual parsing of sport events. The moments of the colour information are computed, and the shape content in the frames is characterised by the moments of local shape measures. Their generation process is very low cost. The temporal evolution of the features then is modelled with a Hidden Markov Model. The HMM is used to generate higher level information by classifying the shots as close ups, court views, crowd shots and so on. The paper illustrates how those simple features, coupled with the HMM, can be used for parsing snooker and tennis footages.

  10. Lead exposure in Canada geese of the Eastern Prairie Population

    Science.gov (United States)

    DeStefano, S.; Brand, C.J.; Rusch, D.H.; Finley, Daniel L.; Gillespie, M.M.

    1991-01-01

    We monitored lead exposure in Eastern Prairie Population Canada geese during summer-winter, 1986-1987 and 1987-1988 at 5 areas. Blood lead concentrations in geese trapped during summer at Cape Churchill Manitoba were below levels indicative of recent lead exposure (0.18 ppm). Geese exposed to lead (≥0.18 ppm blood lead) increased to 7.6% at Oak Hammock Wildlife Management Area (WMA), southern Manitoba, where lead shot was still in use, and to 10.0% at Roseau River WMA, northern Minnesota, when fall-staging geese were close to a source of lead shot in Manitoba. Proportion of birds exposed to lead dropped to exposure to lead before the hunting season. Lead exposure rose to 10.0% after hunting ended and then decreased to 5.2% in late winter. Incidence of lead shot in gizzards and concentrations of lead in livers supported blood assay data. Soil samples indicated that lead shot continues to be available to geese at Swan Lake, even though the area was established as a non-toxic shot zone in 1978. Steel shot zones have reduced lead exposure in the Eastern Prairie Population, but lead shot persists in the environment and continues to account for lead exposure and mortality in Eastern Prairie Population Canada geese.

  11. Increasing shot and data collection rates of the Shock/Shear experiment at the National Ignition Facility

    International Nuclear Information System (INIS)

    Doss, F. W.; Flippo, K. A.; Capelli, D.; Cardenas, T.; DeVolder, B.; Kline, J.; Kot, L.; Kurien, S.; Loomis, E.; Merritt, E. C.; Perry, T.; Schmidt, D.; Di Stefano, C.

    2016-01-01

    Updates to the Los Alamos laser-driven high-energy-density Shock/Shear mixing- layer experiment are reported, which have collectively increased the platform's shot and data acquisition rates. The strategies employed have included a move from two-strip to four-strip imagers (allowing four times to be recorded per shot instead of two), the implementation of physics-informed rules of engagements allowing for the maximum flexibility in a shot's total energy and symmetry performance, and splitting the laser's main drive pulse from a monolithic single pulse equal to all beams into a triply-segmented pulse which minimizes optics damage. (paper)

  12. Shot noise in a harmonically driven ballistic graphene transistor

    Science.gov (United States)

    Korniyenko, Y.; Shevtsov, O.; Löfwander, T.

    2017-04-01

    We study time-dependent electron transport and quantum noise in a ballistic graphene field effect transistor driven by an ac gate potential. The nonlinear response to the ac signal is computed through Floquet theory for scattering states and Landauer-Büttiker theory for charge current and its fluctuations. Photon-assisted excitation of a quasibound state in the top-gate barrier leads to resonances in transmission that strongly influence the noise properties. For strong doping of graphene under source and drain contacts, when electrons are transmitted through the channel via evanescent waves, the resonance leads to a substantial suppression of noise. The Fano factor is then reduced well below the pseudodiffusive value, F tunneling (total suppression of back-reflection) persists for perpendicular incidence also when the barrier is driven harmonically. Although the transmission is inelastic and distributed among sideband energies, a sum rule leads to total suppression of shot noise.

  13. Spectral and Dynamical Properties of Single Excitons, Biexcitons, and Trions in Cesium-Lead-Halide Perovskite Quantum Dots.

    Science.gov (United States)

    Makarov, Nikolay S; Guo, Shaojun; Isaienko, Oleksandr; Liu, Wenyong; Robel, István; Klimov, Victor I

    2016-04-13

    Organic-inorganic lead-halide perovskites have been the subject of recent intense interest due to their unusually strong photovoltaic performance. A new addition to the perovskite family is all-inorganic Cs-Pb-halide perovskite nanocrystals, or quantum dots, fabricated via a moderate-temperature colloidal synthesis. While being only recently introduced to the research community, these nanomaterials have already shown promise for a range of applications from color-converting phosphors and light-emitting diodes to lasers, and even room-temperature single-photon sources. Knowledge of the optical properties of perovskite quantum dots still remains vastly incomplete. Here we apply various time-resolved spectroscopic techniques to conduct a comprehensive study of spectral and dynamical characteristics of single- and multiexciton states in CsPbX3 nanocrystals with X being either Br, I, or their mixture. Specifically, we measure exciton radiative lifetimes, absorption cross-sections, and derive the degeneracies of the band-edge electron and hole states. We also characterize the rates of intraband cooling and nonradiative Auger recombination and evaluate the strength of exciton-exciton coupling. The overall conclusion of this work is that spectroscopic properties of Cs-Pb-halide quantum dots are largely similar to those of quantum dots of more traditional semiconductors such as CdSe and PbSe. At the same time, we observe some distinctions including, for example, an appreciable effect of the halide identity on radiative lifetimes, considerably shorter biexciton Auger lifetimes, and apparent deviation of their size dependence from the "universal volume scaling" previously observed for many traditional nanocrystal systems. The high efficiency of Auger decay in perovskite quantum dots is detrimental to their prospective applications in light-emitting devices and lasers. This points toward the need for the development of approaches for effective suppression of Auger

  14. 3-D analysis of fatigue crack behaviour in a shot peened steam turbine blade material

    Energy Technology Data Exchange (ETDEWEB)

    He, B.Y., E-mail: Binyan.he@soton.ac.uk [Engineering Materials, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Katsamenis, O.L. [muVIS X-ray Imaging Centre, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom); Mellor, B.G.; Reed, P.A.S. [Engineering Materials, Faculty of Engineering and the Environment, University of Southampton, Southampton SO17 1BJ (United Kingdom)

    2015-08-26

    Serial mechanical sectioning and high resolution X-ray tomography have been used to study the three-dimensional morphology of small fatigue cracks growing in a 12 Cr tempered martensitic steam turbine blade material. A range of surface conditions has been studied, namely polished and shot peened (with varying levels of intensity). In the polished (unpeened) condition, inclusions (alumina and manganese sulphide) played an important role in initiating and controlling early fatigue crack behaviour. When fatigue cracks initiated from an alumina stringer, the crack morphology was normally dominated by single stringers, which were always in the centre of the fatigue crack, indicating its primary role in initiation. Manganese sulphide inclusion groups however seemed to dominate and affect the crack path along both the surface and depth crack growth directions. The more intensely shot peened condition did not however evidence inclusion or stringer affected fatigue crack initiation or growth behaviour; sub-surface crack coalescence being clearly observed by both serial sectioning and computed tomography (CT) imaging techniques at a depth of about 150–180 μm. These sub-surface crack coalescences can be linked to both the extent of the compressive residual stress as well as the depth of the plastic deformation arising from the intense shot peening process. Shot peening appears to provide a different defect population that initiates fatigue cracks and competes with the underlying metallurgical defect populations. The most beneficial shot peening process would in this case appear to “deactivate” the original metallurgical defect population and substitute a known defect distribution from the shot peening process from which fatigue cracks grow rather slowly in the strain hardened surface layer which also contains compressive residual stresses. A benefit to fatigue life in bending, even under Low Cycle Fatigue (LCF) conditions, has been observed in these tests if a

  15. 3-D analysis of fatigue crack behaviour in a shot peened steam turbine blade material

    International Nuclear Information System (INIS)

    He, B.Y.; Katsamenis, O.L.; Mellor, B.G.; Reed, P.A.S.

    2015-01-01

    Serial mechanical sectioning and high resolution X-ray tomography have been used to study the three-dimensional morphology of small fatigue cracks growing in a 12 Cr tempered martensitic steam turbine blade material. A range of surface conditions has been studied, namely polished and shot peened (with varying levels of intensity). In the polished (unpeened) condition, inclusions (alumina and manganese sulphide) played an important role in initiating and controlling early fatigue crack behaviour. When fatigue cracks initiated from an alumina stringer, the crack morphology was normally dominated by single stringers, which were always in the centre of the fatigue crack, indicating its primary role in initiation. Manganese sulphide inclusion groups however seemed to dominate and affect the crack path along both the surface and depth crack growth directions. The more intensely shot peened condition did not however evidence inclusion or stringer affected fatigue crack initiation or growth behaviour; sub-surface crack coalescence being clearly observed by both serial sectioning and computed tomography (CT) imaging techniques at a depth of about 150–180 μm. These sub-surface crack coalescences can be linked to both the extent of the compressive residual stress as well as the depth of the plastic deformation arising from the intense shot peening process. Shot peening appears to provide a different defect population that initiates fatigue cracks and competes with the underlying metallurgical defect populations. The most beneficial shot peening process would in this case appear to “deactivate” the original metallurgical defect population and substitute a known defect distribution from the shot peening process from which fatigue cracks grow rather slowly in the strain hardened surface layer which also contains compressive residual stresses. A benefit to fatigue life in bending, even under Low Cycle Fatigue (LCF) conditions, has been observed in these tests if a

  16. Light emission probing quantum shot noise and charge fluctuations at a biased molecular junction

    DEFF Research Database (Denmark)

    Schneider, N.L.; Lu, Jing Tao; Brandbyge, M.

    2012-01-01

    The emission of plasmonic light from a single C60 molecule on Cu(111) is probed in a scanning tunneling microscope from the weak-coupling, tunneling range to strong coupling of the molecule to the electrodes at contact. At positive sample voltage the photon yield decreases owing to shot...

  17. Estimation of a respiratory signal from a single-lead ECG using the 4th order central moments

    Directory of Open Access Journals (Sweden)

    Schmidt Marcus

    2015-09-01

    Full Text Available For a variety of clinical applications like magnetic resonance imaging (MRI the monitoring of vital signs is a common standard in clinical daily routine. Besides the electrocardiogram (ECG, the respiratory activity is an important vital parameter and might reveal pathological changes. Thoracic movement and the resulting impedance change between ECG electrodes enable the estimation of the respiratory signal from the ECG. This ECG-derived respiration (EDR can be used to calculate the breathing rate without the need for additional devices or monitoring modules. In this paper a new method is presented to estimate the respiratory signal from a single-lead ECG. The 4th order central moments was used to estimate the EDR signal exploiting the change of the R-wave slopes induced by respiration. This method was compared with two approaches by analyzing the Fantasia database from www.physionet.org. Furthermore, the ECG signals of 24 healthy subjects placed in an 3 T MR-scanner were acquired.

  18. Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines

    Directory of Open Access Journals (Sweden)

    Wm M. Wood

    2018-02-01

    Full Text Available A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t, and current, I(t. The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. “Goodness of fit” is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays (“MCNPX” model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.

  19. Shot-by-shot spectrum model for rod-pinch, pulsed radiography machines

    Science.gov (United States)

    Wood, Wm M.

    2018-02-01

    A simplified model of bremsstrahlung production is developed for determining the x-ray spectrum output of a rod-pinch radiography machine, on a shot-by-shot basis, using the measured voltage, V(t), and current, I(t). The motivation for this model is the need for an agile means of providing shot-by-shot spectrum prediction, from a laptop or desktop computer, for quantitative radiographic analysis. Simplifying assumptions are discussed, and the model is applied to the Cygnus rod-pinch machine. Output is compared to wedge transmission data for a series of radiographs from shots with identical target objects. Resulting model enables variation of parameters in real time, thus allowing for rapid optimization of the model across many shots. "Goodness of fit" is compared with output from LSP Particle-In-Cell code, as well as the Monte Carlo Neutron Propagation with Xrays ("MCNPX") model codes, and is shown to provide an excellent predictive representation of the spectral output of the Cygnus machine. Improvements to the model, specifically for application to other geometries, are discussed.

  20. Two-shot point-diffraction interferometer with an unknown phase shift

    International Nuclear Information System (INIS)

    Bai, Fuzhong; Liu, Zhen; Bao, Xiaoyan

    2010-01-01

    On the basis of a modified Mach–Zehnder interferometer, this paper proposes a two-shot point-diffraction interferometer (PDI), by which two π-shifted interferograms are created according to the principle of half-wave loss and are simultaneously captured by a single CCD camera. After an arbitrary unknown phase shift is induced, a second and final shot captures these last two patterns. Then a novel algorithm based on statistical principles is developed to extract the actual phase shift and the wavefront phase from four interferograms. The combination of two required shots and a robust algorithm allows the proposed PDI to be implemented efficiently and accurately. Related simulation and experiments are conducted to prove the correctness of the proposed method

  1. A Shot Number Based Approach to Performance Analysis in Table Tennis

    Directory of Open Access Journals (Sweden)

    Tamaki Sho

    2017-01-01

    Full Text Available The current study proposes a novel approach that improves the conventional performance analysis in table tennis by introducing the concept of frequency, or the number of shots, of each shot number. The improvements over the conventional method are as follows: better accuracy of the evaluation of skills and tactics of players, additional insights into scoring and returning skills and ease of understanding the results with a single criterion. The performance analysis of matches played at the 2012 Summer Olympics in London was conducted using the proposed method. The results showed some effects of the shot number and gender differences in table tennis. Furthermore, comparisons were made between Chinese players and players from other countries, what threw light on the skills and tactics of the Chinese players. The present findings demonstrate that the proposed method provides useful information and has some advantages over the conventional method.

  2. A Shot Number Based Approach to Performance Analysis in Table Tennis.

    Science.gov (United States)

    Tamaki, Sho; Yoshida, Kazuto; Yamada, Koshi

    2017-01-01

    The current study proposes a novel approach that improves the conventional performance analysis in table tennis by introducing the concept of frequency, or the number of shots, of each shot number. The improvements over the conventional method are as follows: better accuracy of the evaluation of skills and tactics of players, additional insights into scoring and returning skills and ease of understanding the results with a single criterion. The performance analysis of matches played at the 2012 Summer Olympics in London was conducted using the proposed method. The results showed some effects of the shot number and gender differences in table tennis. Furthermore, comparisons were made between Chinese players and players from other countries, what threw light on the skills and tactics of the Chinese players. The present findings demonstrate that the proposed method provides useful information and has some advantages over the conventional method.

  3. Multistage electrotherapy delivered through chronically-implanted leads terminates atrial fibrillation with lower energy than a single biphasic shock.

    Science.gov (United States)

    Janardhan, Ajit H; Gutbrod, Sarah R; Li, Wenwen; Lang, Di; Schuessler, Richard B; Efimov, Igor R

    The goal of this study was to develop a low-energy, implantable device-based multistage electrotherapy (MSE) to terminate atrial fibrillation (AF). Previous attempts to perform cardioversion of AF by using an implantable device were limited by the pain caused by use of a high-energy single biphasic shock (BPS). Transvenous leads were implanted into the right atrium (RA), coronary sinus, and left pulmonary artery of 14 dogs. Self-sustaining AF was induced by 6 ± 2 weeks of high-rate RA pacing. Atrial defibrillation thresholds of standard versus experimental electrotherapies were measured in vivo and studied by using optical imaging in vitro. The mean AF cycle length (CL) in vivo was 112 ± 21 ms (534 beats/min). The impedances of the RA-left pulmonary artery and RA-coronary sinus shock vectors were similar (121 ± 11 Ω vs. 126 ± 9 Ω; p = 0.27). BPS required 1.48 ± 0.91 J (165 ± 34 V) to terminate AF. In contrast, MSE terminated AF with significantly less energy (0.16 ± 0.16 J; p < 0.001) and significantly lower peak voltage (31.1 ± 19.3 V; p < 0.001). In vitro optical imaging studies found that AF was maintained by localized foci originating from pulmonary vein-left atrium interfaces. MSE Stage 1 shocks temporarily disrupted localized foci; MSE Stage 2 entrainment shocks continued to silence the localized foci driving AF; and MSE Stage 3 pacing stimuli enabled consistent RA-left atrium activation until sinus rhythm was restored. Low-energy MSE significantly reduced the atrial defibrillation thresholds compared with BPS in a canine model of AF. MSE may enable painless, device-based AF therapy. Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  4. Real time analysis of lead-containing atmospheric particles in Beijing during springtime by single particle aerosol mass spectrometry.

    Science.gov (United States)

    Ma, Li; Li, Mei; Huang, Zhengxu; Li, Lei; Gao, Wei; Nian, Huiqing; Zou, Lilin; Fu, Zhong; Gao, Jian; Chai, Fahe; Zhou, Zhen

    2016-07-01

    Using a single particle aerosol mass spectrometer (SPAMS), the chemical composition and size distributions of lead (Pb)-containing particles with diameter from 0.1 μm to 2.0 μm in Beijing were analyzed in the spring of 2011 during clear, hazy, and dusty days. Based on mass spectral features of particles, cluster analysis was applied to Pb-containing particles, and six major classes were acquired consisting of K-rich, carboneous, Fe-rich, dust, Pb-rich, and Cl-rich particles. Pb-containing particles accounted for 4.2-5.3%, 21.8-22.7%, and 3.2% of total particle number during clear, hazy and dusty days, respectively. K-rich particles are a major contribution to Pb-containing particles, varying from 30.8% to 82.1% of total number of Pb-containing particles, lowest during dusty days and highest during hazy days. The results reflect that the chemical composition and amount of Pb-containing particles has been affected by meteorological conditions as well as the emissions of natural and anthropogenic sources. K-rich particles and carbonaceous particles could be mainly assigned to the emissions of coal combustion. Other classes of Pb-containing particles may be associated with metallurgical processes, coal combustion, dust, and waste incineration etc. In addition, Pb-containing particles during dusty days were first time studied by SPAMS. This method could provide a powerful tool for monitoring and controlling of Pb pollution in real time. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. Shot-Noise Limited Time-Encoded Raman Spectroscopy

    Directory of Open Access Journals (Sweden)

    Sebastian Karpf

    2017-01-01

    Full Text Available Raman scattering, an inelastic scattering mechanism, provides information about molecular excitation energies and can be used to identify chemical compounds. Albeit being a powerful analysis tool, especially for label-free biomedical imaging with molecular contrast, it suffers from inherently low signal levels. This practical limitation can be overcome by nonlinear enhancement techniques like stimulated Raman scattering (SRS. In SRS, an additional light source stimulates the Raman scattering process. This can lead to orders of magnitude increase in signal levels and hence faster acquisition in biomedical imaging. However, achieving a broad spectral coverage in SRS is technically challenging and the signal is no longer background-free, as either stimulated Raman gain (SRG or loss (SRL is measured, turning a sensitivity limit into a dynamic range limit. Thus, the signal has to be isolated from the laser background light, requiring elaborate methods for minimizing detection noise. Here, we analyze the detection sensitivity of a shot-noise limited broadband stimulated time-encoded Raman (TICO-Raman system in detail. In time-encoded Raman, a wavelength-swept Fourier domain mode locking (FDML laser covers a broad range of Raman transition energies while allowing a dual-balanced detection for lowering the detection noise to the fundamental shot-noise limit.

  6. Few-shot learning in deep networks through global prototyping.

    Science.gov (United States)

    Blaes, Sebastian; Burwick, Thomas

    2017-10-01

    Training a deep convolution neural network (CNN) to succeed in visual object classification usually requires a great number of examples. Here, starting from such a pre-learned CNN, we study the task of extending the network to classify additional categories on the basis of only few examples ("few-shot learning"). We find that a simple and fast prototype-based learning procedure in the global feature layers ("Global Prototype Learning", GPL) leads to some remarkably good classification results for a large portion of the new classes. It requires only up to ten examples for the new classes to reach a plateau in performance. To understand this few-shot learning performance resulting from GPL as well as the performance of the original network, we use the t-SNE method (Maaten and Hinton, 2008) to visualize clusters of object category examples. This reveals the strong connection between classification performance and data distribution and explains why some new categories only need few examples for learning while others resist good classification results even when trained with many more examples. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. NASTRAN multipartitioning and one-shot substructuring

    Science.gov (United States)

    Levy, A.

    1973-01-01

    For intermediate size problems where all the data is accessible, the present method of substructuring in three separate phases (for static analysis) is unneccessarily cumbersome. The versatility of NASTRAN's DMAP and internal logic lends itself to finding a practical alternative to these procedures whereby self-contained special-purpose ALTER packages can be written to be run in one pass. Two examples are presented here under the titles of multipartitioning and one-shot substructuring. The flow of multipartitioning resembles that of the present three-phase substructuring. The basic effect is to partition the structure into substructures and operate on each substructure separately. This can be used to reduce the bandwidth of a given problem as well as to store information which will allow a change to be made in one of the substructures in a later run. This latter procedure is carried out in a second program titled one-shot substructuring.

  8. The Slap Shot in Ice Hockey

    Science.gov (United States)

    Cross, Rod; Lindsey, Crawford

    2018-01-01

    An ice hockey player can strike a puck at speeds up to about 45 m/s (100 mph) using a technique known as the slap shot. There is nothing unusual about the speed, since golf balls, tennis balls, and baseballs can also be projected at that speed or even higher. The unusual part is that the player strikes the ice before striking the puck, causing the…

  9. SnapShot: GI tract development.

    Science.gov (United States)

    McGrath, Patrick S; Wells, James M

    2015-03-26

    The endoderm germ layer contributes to the respiratory and gastrointestinal (GI) lineages during development, giving rise to an array of specialized epithelial cell types lining organs, including the thyroid, thymus, lungs, liver, biliary system, pancreas, and intestines. This SnapShot timelines and summarizes key stages following gastrulation, including endoderm patterning, organ specification, and organogenesis. A lineage tree of the developing endocrine pancreas is outlined to further illustrate this process. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Centrifugal shot blasting. Innovative technology summary report

    International Nuclear Information System (INIS)

    1999-07-01

    At the US Department of Energy (DOE) Fernald Environmental Management Project (FEMP), the Facilities Closure and Demolition Projects Integrated Remedial Design/Remedial Action (RD/RA) work plan calls for the removal of one inch (1 in) depth of concrete surface in areas where contamination with technetium-99 has been identified. This report describes a comparative demonstration between two concrete removal technologies: an innovative system using Centrifugal Shot Blasting (CSB) and a modified baseline technology called a rotary drum planer

  11. Beauty and science in a shot

    Science.gov (United States)

    Ciceri, Piera

    2017-04-01

    Taking pictures has become a daily action for young. Photography is an essential component of many areas of science, has played a crucial role in the study of anatomy, botany, archeology, ... Still today it is a "scientific tool" in the school textbooks: pictures describe, make reality larger or smaller, faster or slower, show evidence and experimental results. But a photograph has the ability to move, engage and inspire viewers. That means that a photograph can build an emotional bridge between science and people. People and students can get closer to science through beautiful, evocative and expressive shot. In this project students are involved in taking pictures with a scientific and aesthetic content looking around, setting an experiment, watching nature, playing with light, point of wiew, colors and perspective. They have to write a short text and a title that explains the scientific content, why and how they have taken the picture. Both description and title should let increase curiosity, could looks fun or stress artistic aspects. Student show their shots in an official public event in Milan managed by a committee of science and photograph experts and in a local event to parents and local community. "Shots of science" is a project promoted by the italian national association "Scienza under 18", the Physic Department of "Università degli Studi di Milano" and the "Museo di fotografia contemporanea" of Cinisello Balsamo (MI) that help students in discussing about scientific and artistic aspects of their shots. This project contributes to develop digital skills (such as to manage digital images, to share documents, to learn about copyright and creative commons license), communication skills (such as to write a caption, public speaking, to use a picture to communicate), collaboration skills (such as to work with pairs, to respect scheduled times, to be positive in giving and taking into account suggestions) and artistic skills (to learn how to compose a good

  12. Osseointegration improvement by shot peening in titanium dental implants

    International Nuclear Information System (INIS)

    Aparicio, C.; Gil, F.J.; Planell, J.A.; Padros, A.; Peraire, C.

    1998-01-01

    In order to optimize the implant-bone fixation, different shot peening treatments with different shot particles (TiO 2 , Al 2 O 3 ; SiC) have been made. The influence that each type of shot particle has in the bone colonization on the different treatment surfaces has been determined by means of osteoblast-like cells culture. Commercially pure titanium discs have been shot peened. Their qualitative and quantitative surface roughness have been characterized; as well as their surface contamination caused by the shot particles. Particle size has also been determined, before and after the treatment, in order to evaluate their breaking averages. Finally, a TiO 2 shot particles manufacture process by sintering has been developed. The manufacture has been necessary since this type of shot particles are not available in the market with the adequate size. (Author) 10 refs

  13. Single-molecule analysis of lead(II)-binding aptamer conformational changes in an α-hemolysin nanopore, and sensitive detection of lead(II)

    International Nuclear Information System (INIS)

    Wang, Hai-Yan; Song, Ze-Yang; Zhang, Hui-Sheng; Chen, Si-Ping

    2016-01-01

    The α-hemolysin (αHL) nanopore is capable of analyzing DNA duplex and DNA aptamer as they can be electrophoretically driven into the vestibule from the cis entrance. The current study describes the competitive interaction induced by Pb 2+ that changes the secondary structure of DNA duplex in asymmetrical electrolyte solution. DNA duplex formed by the partial complementary DNA and DNA aptamer sequence produced unzipping blockages with the dwell unzipping time lasting 2.84 ± 0.7 ms. By cation-DNA interaction with Pb 2+ , the DNA duplex will unwind and then form Pb 2+ -stabilized-DNA aptamer, which will be captured and unfolded in vestibule. The pore conductance were reduced to 54 % and 94 % with mean dwell unfolding times of 165 ± 12 ms. The competitive behavior between Pb 2+ and single-strand DNA was further utilized to detect Pb 2+ in solution with a detection limit of 0.5 nM. This nanopore platform also provides a powerful tool for studying the cation-DNA interactions in DNA aptamer conformational changes. Thus, the results drawn from these studies provide insights into the applications of α-hemolysin nanopore as a molecular sieve to different DNA secondary structure in future application of nanopore analysis. (author)

  14. High-resolution three-dimensional diffusion-weighted imaging of middle ear cholesteatoma at 3.0 T MRI: Usefulness of 3D turbo field-echo with diffusion-sensitized driven-equilibrium preparation (TFE–DSDE) compared to single-shot echo-planar imaging

    International Nuclear Information System (INIS)

    Yamashita, Koji; Yoshiura, Takashi; Hiwatashi, Akio; Obara, Makoto; Togao, Osamu; Matsumoto, Nozomu; Kikuchi, Kazufumi; Honda, Hiroshi

    2013-01-01

    Objective: To prospectively evaluate the usefulness of a newly developed high-resolution three-dimensional diffusion-weighted imaging method, turbo field-echo with diffusion-sensitized driven-equilibrium (TFE–DSDE) in diagnosing middle-ear cholesteatoma by comparing it to conventional single-shot echo-planar diffusion-weighted imaging (SS-EP DWI). Materials and methods: Institutional review board approval and informed consent from all participants were obtained. We studied 30 patients with preoperatively suspected acquired cholesteatoma. Each patient underwent an MR examination including both SS-EP DWI and DSDE-TFE using a 3.0 T MR scanner. Images of the 30 patients (60 temporal bones including 30 with and 30 without cholesteatoma) were reviewed by two independent neuroradiologists. The confidence level for the presence of cholesteatoma was graded on a scale of 0–2 (0 = definite absence, 1 = equivocal, 2 = definite presence). Interobserver agreement as well as sensitivity, specificity, and accuracy for detection were assessed for the two reviewers. Results: Excellent interobserver agreement was shown for TFE–DSDE (κ = 0.821) whereas fair agreement was obtained for SS-EP DWI (κ = 0.416). TFE–DSDE was associated with significantly higher sensitivity (83.3%) and accuracy (90.0%) compared to SS-EP DWI (sensitivity = 35.0%, accuracy = 66.7%; p < 0.05). No significant difference was found in specificity (96.7% for TFE–DSDE, 98.3% for SS-EP DWI) Conclusion: With increased spatial resolution and reduced susceptibility artifacts, TFE–DSDE improves the accuracy in diagnosing acquired middle ear cholesteatomas compared to SS-EP DWI

  15. Inorganic Lead Halide Perovskite Single Crystals: Phase-Selective Low-Temperature Growth, Carrier Transport Properties, and Self-Powered Photodetection

    KAUST Repository

    Saidaminov, Makhsud I.

    2016-12-06

    A rapid, low-temperature, and solution-based route is developed for growing large-sized cesium lead halide perovskite single crystals under ambient conditions. An ultralow minority carrier concentration was measured in CsPbBr3 (≈108 holes per cm3, much lower than in any other lead halide perovskite and crystalline silicon), which enables to realize self-powered photodetectors with a high ON/OFF ratio (105).

  16. Quantitative single shot and spatially resolved plasma wakefield diagnostics

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Levy, Matthew C; Ratan, Naren; Sadler, James; Bingham, Robert; Burrows, Philip N; Trines, Raoul; Wing, Matthew; Norreys, Peter

    2015-01-01

    Diagnosing plasma conditions can give great advantages in optimizing plasma wakefield accelerator experiments. One possible method is that of photon acceleration. By propagating a laser probe pulse through a plasma wakefield and extracting the imposed frequency modulation, one can obtain an image of the density modulation of the wakefield. In order to diagnose the wakefield parameters at a chosen point in the plasma, the probe pulse crosses the plasma at oblique angles relative to the wakefield. In this paper, mathematical expressions relating the frequency modulation of the laser pulse and the wakefield density profile of the plasma for oblique crossing angles are derived. Multidimensional particle-in-cell simulation results presented in this paper confirm that the frequency modulation profiles and the density modulation profiles agree to within 10%. Limitations to the accuracy of the measurement are discussed in this paper. This technique opens new possibilities to quantitatively diagnose the plasma wakefie...

  17. The challenges of single-shot spinal anaesthesia for cesearean ...

    African Journals Online (AJOL)

    An unusual case of morbid obesity, severe hypertension and twin gestation at 36weeks in an unbooked multigravid patient was presented for cesarean section. She was referred from a private clinic to the obstetric emergency unit of the University College Hospital, Ibadan with history of hypertension in pregnancy. She was ...

  18. Josephson radiation and shot noise of a semiconductor nanowire junction

    Science.gov (United States)

    van Woerkom, David J.; Proutski, Alex; van Gulik, Ruben J. J.; Kriváchy, Tamás; Car, Diana; Plissard, Sébastian R.; Bakkers, Erik P. A. M.; Kouwenhoven, Leo P.; Geresdi, Attila

    2017-09-01

    We measured the Josephson radiation emitted by an InSb semiconductor nanowire junction utilizing photon-assisted quasiparticle tunneling in an ac-coupled superconducting tunnel junction. We quantify the action of the local microwave environment by evaluating the frequency dependence of the inelastic Cooper-pair tunneling of the nanowire junction and find the zero-frequency impedance Z (0 )=492 Ω with a cutoff frequency of f0=33.1 GHz . We extract a circuit coupling efficiency of η ≈0.1 and a detector quantum efficiency approaching unity in the high-frequency limit. In addition to the Josephson radiation, we identify a shot noise contribution with a Fano factor F ≈1 , consistently with the presence of single electron states in the nanowire channel.

  19. Atrial electrogram quality in single-pass defibrillator leads with floating atrial bipole in patients with permanent atrial fibrillation and cardiac resynchronization therapy.

    Science.gov (United States)

    Sticherling, Christian; Müller, Dirk; Schaer, Beat A; Krüger, Silke; Kolb, Christof

    2018-03-27

    Many patients receiving cardiac resynchronization therapy (CRT) suffer from permanent atrial fibrillation (AF). Knowledge of the atrial rhythm is important to direct pharmacological or interventional treatment as well as maintaining AV-synchronous biventricular pacing if sinus rhythm can be restored. A single pass single-coil defibrillator lead with a floating atrial bipole has been shown to obtain reliable information about the atrial rhythm but has never been employed in a CRT-system. The purpose of this study was to assess the feasibility of implanting a single coil right ventricular ICD lead with a floating atrial bipole and the signal quality of atrial electrograms (AEGM) in CRT-defibrillator recipients with permanent AF. Seventeen patients (16 males, mean age 73 ± 6 years, mean EF 25 ± 5%) with permanent AF and an indication for CRT-defibrillator placement were implanted with a designated CRT-D system comprising a single pass defibrillator lead with a atrial floating bipole. They were followed-up for 103 ± 22 days using remote monitoring for AEGM transmission. All patients had at last one AEGM suitable for atrial rhythm diagnosis and of 100 AEGM 99% were suitable for visual atrial rhythm assessment. Four patients were discharged in sinus rhythm and one reverted to AF during follow-up. Atrial electrograms retrieved from a single-pass defibrillator lead with a floating atrial bipole can be reliably used for atrial rhythm diagnosis in CRT recipients with permanent AF. Hence, a single pass ventricular defibrillator lead with a floating bipole can be considered in this population. Copyright © 2018 Indian Heart Rhythm Society. Production and hosting by Elsevier B.V. All rights reserved.

  20. Digital Holography at Shot Noise Level

    OpenAIRE

    Verpillat, Frédéric; Joud, Fadwa; Atlan, Michael; Gross, Michel

    2012-01-01

    International audience; By a proper arrangement of a digital holography setup, that combines off-axis geometry with phase-shifting recording conditions, it is possible to reach the theoretical shot noise limit, in real-time experiments.We studied this limit, and we show that it corresponds to 1 photo-electron per pixel within the whole frame sequence that is used to reconstruct the holographic image. We also show that Monte Carlo noise synthesis onto holograms measured at high illumination le...

  1. Shuttlecock Velocity of a Badminton Drop Shot

    Directory of Open Access Journals (Sweden)

    Ampharin Ongvises

    2013-12-01

    Full Text Available In a badminton ‘drop shot’, the shuttlecock is struck by a non-rotating racquet at low speed. In this investigation, a shuttlecock was hit by a badminton racquet in a linear collision, simulating a drop shot. The collision was recorded with high-speed video and the velocities of the racquet and shuttlecock determined. The relationship between the impact velocity of the racquet and the velocity of the shuttlecock as it leaves the badminton racquet after collision was found to be proportional over the range tested.

  2. SnapShot: Phosphoregulation of Mitosis.

    Science.gov (United States)

    Burgess, Andrew; Vuong, Jenny; Rogers, Samuel; Malumbres, Marcos; O'Donoghue, Seán I

    2017-06-15

    During mitosis, a cell divides its duplicated genome into two identical daughter cells. This process must occur without errors to prevent proliferative diseases (e.g., cancer). A key mechanism controlling mitosis is the precise timing of more than 32,000 phosphorylation and dephosphorylation events by a network of kinases and counterbalancing phosphatases. The identity, magnitude, and temporal regulation of these events have emerged recently, largely from advances in mass spectrometry. Here, we show phosphoevents currently believed to be key regulators of mitosis. For an animated version of this SnapShot, please see http://www.cell.com/cell/enhanced/odonoghue2. Copyright © 2017. Published by Elsevier Inc.

  3. Concrete Cleaning, Inc. centrifugal shot blaster: Baseline report; Summary

    International Nuclear Information System (INIS)

    1997-01-01

    The centrifugal shot blaster is an electronically operated shot-blast machine that removes layer of concrete of varying depths. Hardened steel shot propelled at a high rate of speed abrades the surface of the concrete. The depth of material removed is determined by the rate of speed the machine is traveling and the volume of shot being fired into the blast chamber. The steel shot is reused until it is pulverized to dust, which is deposited in the waste container with the concrete being removed. Debris is continually vacuumed by a large dust collection system attached to the shot blaster. The safety and health evaluation during the human factors assessment focused on two main areas: noise and dust

  4. Growth of Ca, Zr co-doped BaTiO3 lead-free ferroelectric single crystal and its room-temperature piezoelectricity

    Science.gov (United States)

    Liu, Donglin; Shim, Jaeshik; Sun, Yue; Li, Qiang; Yan, Qingfen

    2017-09-01

    Lead-free Ca, Zr co-doped BaTiO3 (BCZT) single crystal with a dimension up to 2mm×2mm×2mm was grown by a spontaneous nucleation technique using KF as the flux. The composition of the studied single crystal was defined to be Ba0.798Ca0.202Zr0.006Ti0.994O3, corresponding to a tetragonal phase at room temperature. The oriented single crystal exhibited a quasi-static piezoelectric constant of approximately 232 pC/N. The effective piezoelectric coefficient d33* of the single domain crystal obtained under a unipolar electric field of 35 kV/cm was 179 pm/V. Rayleigh analysis was used to identify the intrinsic and extrinsic contributions to the room-temperature piezoelectricity of BCZT single crystal. The extrinsic contribution was estimated up to 40% due to the irreversible domain wall movement. Furthermore a sixth-order polynomial of Landau expansion was employed to analyze the intrinsic contribution to piezoelectricity of BCZT single crystal. The large energy barriers inhibited polarization rotations, leading to the relatively low piezoelectricity.

  5. Growth of Ca, Zr co-doped BaTiO3 lead-free ferroelectric single crystal and its room-temperature piezoelectricity

    Directory of Open Access Journals (Sweden)

    Donglin Liu

    2017-09-01

    Full Text Available Lead-free Ca, Zr co-doped BaTiO3 (BCZT single crystal with a dimension up to 2mm×2mm×2mm was grown by a spontaneous nucleation technique using KF as the flux. The composition of the studied single crystal was defined to be Ba0.798Ca0.202Zr0.006Ti0.994O3, corresponding to a tetragonal phase at room temperature. The oriented single crystal exhibited a quasi-static piezoelectric constant of approximately 232 pC/N. The effective piezoelectric coefficient d33* of the single domain crystal obtained under a unipolar electric field of 35 kV/cm was 179 pm/V. Rayleigh analysis was used to identify the intrinsic and extrinsic contributions to the room-temperature piezoelectricity of BCZT single crystal. The extrinsic contribution was estimated up to 40% due to the irreversible domain wall movement. Furthermore a sixth-order polynomial of Landau expansion was employed to analyze the intrinsic contribution to piezoelectricity of BCZT single crystal. The large energy barriers inhibited polarization rotations, leading to the relatively low piezoelectricity.

  6. Catastrophe insurance modeled by shot-noise processes

    OpenAIRE

    Schmidt, Thorsten

    2014-01-01

    Shot-noise processes generalize compound Poisson processes in the following way: a jump (the shot) is followed by a decline (noise). This constitutes a useful model for insurance claims in many circumstances; claims due to natural disasters or self-exciting processes exhibit similar features. We give a general account of shot-noise processes with time-inhomogeneous drivers inspired by recent results in credit risk. Moreover, we derive a number of useful results for modeling and pricing with s...

  7. Biomechanical Analysis of the Jump Shot in Basketball

    OpenAIRE

    Struzik Artur; Pietraszewski Bogdan; Zawadzki Jerzy

    2014-01-01

    Basketball players usually score points during the game using the jump shot. For this reason, the jump shot is considered to be the most important element of technique in basketball and requires a high level of performance. The aim of this study was to compare the biomechanical characteristics of the lower limbs during a jump shot without the ball and a countermovement jump without an arm swing. The differences between variables provide information about the potential that an athlete can util...

  8. Contemporary rates and outcomes of single- vs. dual-coil implantable cardioverter defibrillator lead implantation: data from the Israeli ICD Registry.

    Science.gov (United States)

    Leshem, Eran; Suleiman, Mahmoud; Laish-Farkash, Avishag; Konstantino, Yuval; Glikson, Michael; Barsheshet, Alon; Goldenberg, Ilan; Michowitz, Yoav

    2017-09-01

    Dual-coil leads were traditionally considered standard of care due to lower defibrillation thresholds (DFT). Higher complication rates during extraction with parallel progression in implantable cardioverter defibrillator (ICD) technology raised questions on dual coil necessity. Prior substudies found no significant outcome difference between dual and single coils, although using higher rates of DFT testing then currently practiced. We evaluated the temporal trends in implantation rates of single- vs. dual-coil leads and determined the associated adverse clinical outcomes, using a contemporary nation-wide ICD registry. Between July 2010 and March 2015, 6343 consecutive ICD (n = 3998) or CRT-D (n = 2345) implantation patients were prospectively enrolled in the Israeli ICD Registry. A follow-up of at least 1 year of 2285 patients was available for outcome analysis. The primary endpoint was all-cause mortality. Single-coil leads were implanted in 32% of our cohort, 36% among ICD recipients, and 26% among CRT-D recipients. Secondary prevention indication was associated with an increased rate of dual-coil implantation. A significant decline in dual-coil leads with reciprocal incline of single coils was observed, despite low rates of DFT testing (11.6%) during implantation, which also declined from 31 to 2%. In the multivariate Cox model analysis, dual- vs. single-coil lead implantation was not associated with an increased risk of mortality [hazard ratio (HR) = 1.23; P= 0.33], heart failure hospitalization (HR = 1.34; P=0.13), appropriate (HR = 1.25; P= 0.33), or inappropriate ICD therapy (HR = 2.07; P= 0.12). Real-life rates of single-coil lead implantation are rising while adding no additional risk. These results of single-coil safety are reassuring and obtained, despite low and contemporary rates of DFT testing. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  9. Lead in the environment

    Science.gov (United States)

    Pattee, Oliver H.; Pain, Deborah J.; Hoffman, David J.; Rattner, Barnett A.; Burton, G. Allen; Cairns, John

    2003-01-01

    . and the .reduction of lead in gasoline has resulted in lower tissue lead concentrations in humans and wildlife from many, particularly urban, locations. However, it has been suggested that increasing use of organic lead compounds as catalysts for the production of plastics and as wood preservatives and biocides could adversely affect wildlife. The most significant source of direct wildlife mortality from lead is spent gunshot and fishing sinkers. Elevated mortality from shot ingestion in avian species resulted in the introduction of nontoxic (steel) shot zones along certain flyways in the United States in the mid-1970s and a total ban on the use of lead for waterfowl and coot hunting nationwide by 1992. Several other countries are now following suit and have either banned or are in the process of restricting the use of lead shot for waterfowl hunting. In the United States it has been estimated that since the 1986 hunting season. when the use of nontoxic shot became widespread. over 6 million ducks have not been lost to lead poisoning. Raptors, especially eagles, have also apparently benefited. although lead poisoning from ingestion of bullet fragments remains a problem for the critically threatened California condor. Quantifying reductions in lead mortality rates would be difficult since eagle populations throughout North America are rapidly recovering from other anthropogenic perturbations, especially organochlorine pesticides.

  10. Methodology of Testing Shot Blasting Machines in Industrial Conditions

    Directory of Open Access Journals (Sweden)

    R. Wrona

    2012-04-01

    Full Text Available Shot blasting machines are widely used for automated surface treatment and finishing of castings. In shot blasting processes the stream of shots is generated and shaped by blasting turbines, making up a kinetic and dynamic system comprising a separating rotor, an adapting sleeve and a propelling rotor provided with blades. The shot blasting performance- i.e. the quality of shot treated surfaces depends on the actual design and operational parameters of the unit whilst the values of relevant parameters are associated with the geometry of turbine components and the level of its integration with the separator system. The circulation of the blasting medium becomes the integrating factor of the process line, starting from the hopper, through the propeller turbine, casting treatment, separation of contaminated abrasive mixture, to its recycling and reuse.Inferior quality of the abrasive agent (shot and insufficient purity of the abrasive mixture are responsible for low effectiveness of shot blasting. However, most practitioners fail to fully recognise the importance of proper diagnostics of the shot blasting process in industrial conditions. The wearing of major machine components and of the blasting agent and quality of shot treated surfaces are often misinterpreted, hence the need to take into account all factors involved in the process within the frame of a comprehensive methodology.This paper is an attempt to formulate and apply the available testing methods to the engineering practice in industrial conditions.

  11. Entrance, exit, and reentrance of one shot with a shotgun

    DEFF Research Database (Denmark)

    Gulmann, C; Hougen, H P

    1999-01-01

    The case being reported is one of a homicidal shotgun fatality with an unusual wound pattern. A 34-year-old man was shot at close range with a 12-gauge shotgun armed with No. 5 birdshot ammunition. The shot entered the left axillary region, exited through the left infraclavicular region, and ther......The case being reported is one of a homicidal shotgun fatality with an unusual wound pattern. A 34-year-old man was shot at close range with a 12-gauge shotgun armed with No. 5 birdshot ammunition. The shot entered the left axillary region, exited through the left infraclavicular region...

  12. Residual stress redistribution in shot peened samples subject to mechanical loading

    International Nuclear Information System (INIS)

    Buchanan, Dennis J.; John, Reji

    2014-01-01

    Shot peening is a well-established surface treatment process that imparts large compressive residual stresses onto the surface and at shallow depths to retard initiation and growth of fatigue cracks. The plastic deformation developed during the surface treatment sets up a constraint that retains compressive stresses on the surface balanced by tensile residual stresses in the interior. However, component service histories that produce subsequent plastic deformation may redistribute these residual stresses. In most engineering components, this additional plastic deformation is localized to stress concentration sites such as holes, notches, and fillets. In the case of gross plastic deformation where the entire cross section experiences material yielding the residual stress profile may redistribute, resulting in tensile stresses on the outside surface balanced by compression in the interior. This paper describes a series of experiments combined with models to explain the redistribution in residual stress depth profiles subject to applied stresses producing gross plastic strains in shot peened laboratory specimens. The initial room temperature residual stress and plastic strain profiles provide initial conditions for predictions. Model predictions correlate well with experimental results on shot peened dogbone specimens subject to single cycle and fatigue loading conditions at elevated temperature. Experiments on shot peened notched specimens do not exhibit the same stress redistribution even for larger applied stresses

  13. Mitochondrial aminoacyl-tRNA synthetase single-nucleotide polymorphisms that lead to defects in refolding but not aminoacylation

    DEFF Research Database (Denmark)

    Banerjee, Rajat; Reynolds, Noah M; Yadavalli, Srujana S

    2011-01-01

    that mutations in nuclear-encoded components of the mitochondrial translation machinery, such as aminoacyl-tRNA synthetases (aaRSs), can also lead to disease. In some cases, mutations can be directly linked to losses in enzymatic activity; however, for many, their effect is unknown. To investigate how aa...

  14. Lead sources in human diet in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, Peter; Johansen, Poul; Mulvad, Gert

    2004-01-01

    Although blood lead levels have declined in Greenland, they are still elevated despite the fact that lead levels in the Greenland environment are very low. Fragments of lead shot in game birds have been suggested as an important source of dietary exposure, and meals of sea birds, particularly eid...

  15. A single center 14 years study of infectious complications leading to hospitalization of patients with primary antibody deficiencies

    Directory of Open Access Journals (Sweden)

    Setareh Mamishi

    Full Text Available Primary antibody deficiencies (PADs are a heterogeneous group of disorders, characterized by hypogammaglobulinemia and increased susceptibility to bacterial infections, leading to hospitalizations. This study was performed to determine the main infectious causes of hospital admissions in selective Iranian patients with PADs. Forty patients with PADs, who were admitted to the Infectious Ward of Children's Medical Center Hospital during a 14-year period, were reviewed in this study. There were 115 documented episodes of hospital admission during a 14-year period. The average length of hospital stay was 33.30 ± 25.72 days. Pneumonia was the most prominent infection leading to hospitalization among these patients (n = 48, followed by gastroenteritis (n = 23. Other less frequent causes of hospitalization were fever and neutropenia, septic arthritis, encephalitis, orbital cellulitis, sepsis, urinary tract infection, meningitis, oral ulcer, and lung abscess. The most common causative organisms of diarrhea were: Giardia lamblia, followed by Candida albicans, and Salmonella sp. Many patients with PADs suffer from repeated infections leading to hospitalization, in spite of immunoglobulin replacement therapy. Respiratory tract infections were the prominent cause of hospitalization among studied patients, followed by gastrointestinal infections.

  16. Why Some Pool Shots are More Difficult Than Others

    Indian Academy of Sciences (India)

    IAS Admin

    The physics behind the game of billiards is rather well understood as is our grasp of classical me- chanics. We present here a mathematical expla- nation of why slice shots are more difficult than direct shots. Despite a large number of treatises dedicated to the study of physics of billiards, it appears that the simple ...

  17. Bond strength investigation of two shot moulded polymer

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul

    This report on the project “Bond strength investigation of two shot moulded polymers” has been submitted for fulfilling the requirements for the course “Experimental Plastic Technology – 42234” at IPL-DTU. Two shot moulding is a classic manufacturing process to combine two different polymers...

  18. Influence of KF substitution on the ferroelectric phase transition of lead titanate single crystals studied by Brillouin light scattering

    Directory of Open Access Journals (Sweden)

    Seonhyeop Shin

    2015-06-01

    Full Text Available The elastic properties of KF-substituted perovskite lead titanate (PbTiO3 were investigated by dielectric measurements and Brillouin light scattering. The ferroelectric phase transition occurred at substantially lower temperature due to KF substitution, which was attributed to the modification of the covalency in Pb–O and Ti–O bonds. The longitudinal acoustic (LA mode of KF-substituted PbTiO3 showed a frequency softening in the paraelectric phase, which was accompanied by increasing acoustic damping. This indicated that polarization fluctuations responsible for the acoustic anomalies were enhanced by KF substitution.

  19. Single and Combined Exposure to Zinc- and Copper-Containing Welding Fumes Lead to Asymptomatic Systemic Inflammation.

    Science.gov (United States)

    Markert, Agnieszka; Baumann, Ralf; Gerhards, Benjamin; Gube, Monika; Kossack, Veronika; Kraus, Thomas; Brand, Peter

    2016-02-01

    Recently, it has been shown that exposure to welding fumes containing both zinc and copper leads to asymptomatic systemic inflammation in humans as shown by an increase of blood C-reactive protein. In the present study, it was investigated which metal is responsible for this effect. Fifteen healthy male subjects were exposed under controlled conditions to welding fumes containing either zinc, or copper, or copper and zinc. For each exposure blood C-reactive protein increased. Copper- and zinc-containing welding fumes are able to induce systemic inflammation.

  20. Probing the internal energy structure of a serially coupled double quantum dot system with Rashba spin-orbit coupling through finite-frequency shot noise

    Science.gov (United States)

    Xue, Hai-Bin; Liu, Xu-Ping; Chen, Bin

    2018-01-01

    The finite-frequency shot noise of electron transport through a serially coupled double quantum dot system with Rashba spin-orbit coupling is studied based on an effective particle-number-resolved quantum master equation. We demonstrate that the finite-frequency shot noise displays an obvious dip, and the dip position, which is independent of the spin polarizations of the source and drain electrodes, is determined by the energy difference between the coherent singly-occupied eigenstates of the quantum dot system. These results suggest that the dip position of the finite-frequency shot noise can be used to quantitatively extract the information about the energy difference between the coherent singly-occupied eigenstates and the magnitude of Rashba spin-orbit coupling. The predicted properties of the finite-frequency shot noise are of particular interest for understanding of the internal dynamics of the coupled quantum dot systems.

  1. A shot parameter specification subsystem for automated control of PBFA II accelerator shots

    International Nuclear Information System (INIS)

    Spiller, J.L.

    1987-01-01

    The author reports on the shot parameter specification subsystem (SPSS), an integral part of the automatic control system developed for the Particle Beam Fusion Accelerator II (PBFA II). This system has been designed to fully utilize the accelerator by tailoring shot parameters to the needs of the experimenters. The SPSS is the key to this flexibility. Automatic systems will be required on many pulsed power machines for the fastest turnaround, the highest reliability, and most cost effective operation. These systems will require the flexibility and the ease of use that is part of the SPSS. The author discusses how the PBFA II control system has proved to be an effective modular system, flexible enough to meet the demands of both the fast track construction of PBFA II and the control needs of Hermes III. This system is expected to meet the demands of most future machine changes

  2. Catastrophe Insurance Modeled by Shot-Noise Processes

    Directory of Open Access Journals (Sweden)

    Thorsten Schmidt

    2014-02-01

    Full Text Available Shot-noise processes generalize compound Poisson processes in the following way: a jump (the shot is followed by a decline (noise. This constitutes a useful model for insurance claims in many circumstances; claims due to natural disasters or self-exciting processes exhibit similar features. We give a general account of shot-noise processes with time-inhomogeneous drivers inspired by recent results in credit risk. Moreover, we derive a number of useful results for modeling and pricing with shot-noise processes. Besides this, we obtain some highly tractable examples and constitute a useful modeling tool for dynamic claims processes. The results can in particular be used for pricing Catastrophe Bonds (CAT bonds, a traded risk-linked security. Additionally, current results regarding the estimation of shot-noise processes are reviewed.

  3. Maternal hemochromatosis gene H63D single-nucleotide polymorphism and lead levels of placental tissue, maternal and umbilical cord blood

    International Nuclear Information System (INIS)

    Kayaalti, Zeliha; Kaya-Akyüzlü, Dilek; Söylemez, Esma; Söylemezoğlu, Tülin

    2015-01-01

    Human hemochromatosis protein (HFE), a major histocompatibility complex class I-like integral membrane protein, participates in the down regulation of intestinal iron absorption by binding to transferrin receptor (TR). HFE competes with transferrin-bound iron for the TR and thus reduces uptake of iron into cells. On the other hand, a lack of HFE increases the intestinal absorption of iron similarly to iron deficiency associated with increasing in absorption and deposition of lead. During pregnancy, placenta cannot prevent transfer lead to the fetus; even low-level lead poisoning causes neurodevelopmental toxicity in children. The aim of this study was to determine the association between the maternal HFE H63D single-nucleotide polymorphism and lead levels in placental tissue, maternal blood and umbilical cord bloods. The study population comprised 93 mother–placenta pairs. Venous blood from mother was collected to investigate lead levels and HFE polymorphism that was detected by standard PCR–RFLP technique. Cord bloods and placentas were collected for lead levels which were analyzed by dual atomic absorption spectrometer system. The HFE H63D genotype frequencies of mothers were found as 75.3% homozygote typical (HH), 23.6% heterozygote (HD) and 1.1% homozygote atypical (DD). Our study results showed that the placental tissue, umbilical cord and maternal blood lead levels of mothers with HD+DD genotypes were significantly higher than those with HH genotype (p<0.05). The present study indicated for the first time that mothers with H63D gene variants have higher lead levels of their newborn's placentas and umbilical cord bloods. - Highlights: • Mothers with H63D gene variants have higher lead levels of their newborn's umbilical cord blood. • Unborn child of women with HD+DD genotypes may be at increased risk of internal exposure to lead. • Maternal HFE status may have an effect on increased placenta, maternal and cord blood lead levels.

  4. Maternal hemochromatosis gene H63D single-nucleotide polymorphism and lead levels of placental tissue, maternal and umbilical cord blood

    Energy Technology Data Exchange (ETDEWEB)

    Kayaalti, Zeliha, E-mail: kayaalti@ankara.edu.tr [Ankara University, Institute of Forensic Sciences, Ankara (Turkey); Kaya-Akyüzlü, Dilek [Ankara University, Institute of Forensic Sciences, Ankara (Turkey); Söylemez, Esma [Ankara University, Institute of Forensic Sciences, Ankara (Turkey); Middle Black Sea Passage Generation of Agricultural Research Station Director, Tokat (Turkey); Söylemezoğlu, Tülin [Ankara University, Institute of Forensic Sciences, Ankara (Turkey)

    2015-07-15

    Human hemochromatosis protein (HFE), a major histocompatibility complex class I-like integral membrane protein, participates in the down regulation of intestinal iron absorption by binding to transferrin receptor (TR). HFE competes with transferrin-bound iron for the TR and thus reduces uptake of iron into cells. On the other hand, a lack of HFE increases the intestinal absorption of iron similarly to iron deficiency associated with increasing in absorption and deposition of lead. During pregnancy, placenta cannot prevent transfer lead to the fetus; even low-level lead poisoning causes neurodevelopmental toxicity in children. The aim of this study was to determine the association between the maternal HFE H63D single-nucleotide polymorphism and lead levels in placental tissue, maternal blood and umbilical cord bloods. The study population comprised 93 mother–placenta pairs. Venous blood from mother was collected to investigate lead levels and HFE polymorphism that was detected by standard PCR–RFLP technique. Cord bloods and placentas were collected for lead levels which were analyzed by dual atomic absorption spectrometer system. The HFE H63D genotype frequencies of mothers were found as 75.3% homozygote typical (HH), 23.6% heterozygote (HD) and 1.1% homozygote atypical (DD). Our study results showed that the placental tissue, umbilical cord and maternal blood lead levels of mothers with HD+DD genotypes were significantly higher than those with HH genotype (p<0.05). The present study indicated for the first time that mothers with H63D gene variants have higher lead levels of their newborn's placentas and umbilical cord bloods. - Highlights: • Mothers with H63D gene variants have higher lead levels of their newborn's umbilical cord blood. • Unborn child of women with HD+DD genotypes may be at increased risk of internal exposure to lead. • Maternal HFE status may have an effect on increased placenta, maternal and cord blood lead levels.

  5. Time-dependent inhibition of Na+/K+-ATPase induced by single and simultaneous exposure to lead and cadmium

    Science.gov (United States)

    Vasić, V.; Kojić, D.; Krinulović, K.; Čolović, M.; Vujačić, A.; Stojić, D.

    2007-09-01

    Time-dependent interactions of Na+/K+-ATPase, isolated from rat brain synaptic plasma membranes (SPMs), with Cd2+ and Pb2+ ions in a single exposure and in a mixture were investigated in vitro. The interference of the enzyme with these metal ions was studied as a function of different protein concentrations and exposure time. The aim of the work was to investigate the possibility of selective recognition of Cd2+ and Pb2+ ions in a mixture, on the basis of the different rates of their protein-ligand interactions. Decreasing protein concentration increased the sensitivity of Na+/K+-ATPase toward both metals. The selectivity in protein-ligand interactions was obtained by variation of preincubation time (incubation before starting the enzymatic reaction).

  6. Investigation of kinematics of knuckling shot in soccer

    Science.gov (United States)

    Asai, T.; Hong, S.

    2017-02-01

    In this study, we use four high-speed video cameras to investigate the swing characteristics of the kicking leg while delivering the knuckling shot in soccer. We attempt to elucidate the impact process of the kicking foot at the instant of its impact with the ball and the technical mechanisms of the knuckling shot via comparison of its curved motion with that of the straight and curved shots. Two high-speed cameras (Fastcam, Photron Inc., Tokyo, Japan; 1000 fps, 1024 × 1024 pixels) are set up 2 m away from the site of impact with a line of sight perpendicular to the kicking-leg side. In addition, two semi-high-speed cameras (EX-F1, Casio Computer Co., Ltd., Tokyo, Japan; 300 fps; 720 × 480 pixels) are positioned, one at the rear and the other on the kicking-leg side, to capture the kicking motion. We observe that the ankle joint at impact in the knuckling shot flexes in an approximate L-shape in a manner similar to the joint flexing for the curve shot. The hip's external rotation torque in the knuckling shot is greater than those of other shots, which suggests the tendency of the kicker to push the heel forward and impact with the inside of the foot. The angle of attack in the knuckling shot is smaller than that in other shots, and we speculate that this small attack angle is a factor in soccer kicks which generate shots with smaller rotational frequencies of the ball.

  7. Neutral and Charged Exciton Fine Structure in Single Lead Halide Perovskite Nanocrystals Revealed by Magneto-optical Spectroscopy.

    Science.gov (United States)

    Fu, Ming; Tamarat, Philippe; Huang, He; Even, Jacky; Rogach, Andrey L; Lounis, Brahim

    2017-05-10

    Revealing the crystal structure of lead halide perovskite nanocrystals is essential for the optimization of stability of these emerging materials in applications such as solar cells, photodetectors, and light-emitting devices. We use magneto-photoluminescence spectroscopy of individual perovskite CsPbBr 3 nanocrystals as a unique tool to determine their crystal structure, which imprints distinct signatures in the excitonic sublevels of charge complexes at low temperatures. At zero magnetic field, the identification of two classes of photoluminescence spectra, displaying either two or three sublevels in their exciton fine structure, shows evidence for the existence of two crystalline structures, namely tetragonal D 4h and orthorhombic D 2h phases. Magnetic field shifts, splitting, and coupling of the sublevels provide a determination of the diamagnetic coefficient and valuable information on the exciton g-factor and its anisotropic character. Moreover, this spectroscopic study reveals the optical properties of charged excitons and allows the extraction of the electron and hole g-factors for perovskite systems.

  8. Stage-independent, single lead EEG sleep spindle detection using the continuous wavelet transform and local weighted smoothing

    Directory of Open Access Journals (Sweden)

    Athanasios eTsanas

    2015-04-01

    Full Text Available Sleep spindles are critical in characterizing sleep and have been associated with cognitive function and pathophysiological assessment. Typically, their detection relies on the subjective and time-consuming visual examination of electroencephalogram (EEG signal(s by experts, and has led to large inter-rater variability as a result of poor definition of sleep spindle characteristics. Hitherto, many algorithmic spindle detectors inherently make signal stationarity assumptions (e.g. Fourier transform-based approaches which are inappropriate for EEG signals, and frequently rely on additional information which may not be readily available in many practical settings (e.g. more than one EEG channels, or prior hypnogram assessment. This study proposes a novel signal processing methodology relying solely on a single EEG channel, and provides objective, accurate means towards probabilistically assessing the presence of sleep spindles in EEG signals. We use the intuitively appealing continuous wavelet transform (CWT with a Morlet basis function, identifying regions of interest where the power of the CWT coefficients corresponding to the frequencies of spindles (11-16 Hz is large. The potential for assessing the signal segment as a spindle is refined using local weighted smoothing techniques. We evaluate our findings on two databases: the MASS database comprising 19 healthy controls and the DREAMS sleep spindle database comprising eight participants diagnosed with various sleep pathologies. We demonstrate that we can replicate the experts’ sleep spindles assessment accurately in both databases (MASS database: sensitivity: 84%, specificity: 90%, false discovery rate 83%, DREAMS database: sensitivity: 76%, specificity: 92%, false discovery rate: 67%, outperforming six competing automatic sleep spindle detection algorithms in terms of correctly replicating the experts’ assessment of detected spindles.

  9. Blocking-state influence on shot noise and conductance in quantum dots

    Science.gov (United States)

    Harabula, M.-C.; Ranjan, V.; Haller, R.; Fülöp, G.; Schönenberger, C.

    2018-03-01

    Quantum dots (QDs) investigated through electron transport measurements often exhibit varying, state-dependent tunnel couplings to the leads. Under specific conditions, weakly coupled states can result in a strong suppression of the electrical current, and they are correspondingly called blocking states. Using the combination of conductance and shot noise measurements, we investigate blocking states in carbon nanotube (CNT) QDs. We report negative differential conductance and super-Poissonian noise. The enhanced noise is the signature of electron bunching, which originates from random switches between the strongly and weakly conducting states of the QD. Negative differential conductance appears here when the blocking state is an excited state. In this case, at the threshold voltage where the blocking state becomes populated, the current is reduced. Using a master equation approach, we provide numerical simulations reproducing both the conductance and the shot noise pattern observed in our measurements.

  10. Increased Distance of Shooting on Basketball Jump Shot

    OpenAIRE

    Okazaki, Victor Hugo Alves; Rodacki, André Luiz Félix

    2012-01-01

    The present study analyzed the effect of increased distance on basketball jump shot outcome and performance. Ten male expert basketball players were filmed and a number of kinematic variables analyzed during jump shot that were performed from three conditions to represent close, intermediate and far distances (2.8, 4.6, and 6.4m, respectively). Shot accuracy decreased from 59% (close) to 37% (far), in function of the task constraints (p < 0.05). Ball release height decreased (p < 0.05) from 2...

  11. Single-Crystal Thin Films of Cesium Lead Bromide Perovskite Epitaxially Grown on Metal Oxide Perovskite (SrTiO3).

    Science.gov (United States)

    Chen, Jie; Morrow, Darien J; Fu, Yongping; Zheng, Weihao; Zhao, Yuzhou; Dang, Lianna; Stolt, Matthew J; Kohler, Daniel D; Wang, Xiaoxia; Czech, Kyle J; Hautzinger, Matthew P; Shen, Shaohua; Guo, Liejin; Pan, Anlian; Wright, John C; Jin, Song

    2017-09-27

    High-quality metal halide perovskite single crystals have low defect densities and excellent photophysical properties, yet thin films are the most sought after material geometry for optoelectronic devices. Perovskite single-crystal thin films (SCTFs) would be highly desirable for high-performance devices, but their growth remains challenging, particularly for inorganic metal halide perovskites. Herein, we report the facile vapor-phase epitaxial growth of cesium lead bromide perovskite (CsPbBr 3 ) continuous SCTFs with controllable micrometer thickness, as well as nanoplate arrays, on traditional oxide perovskite SrTiO 3 (100) substrates. Heteroepitaxial single-crystal growth is enabled by the serendipitous incommensurate lattice match between these two perovskites, and overcoming the limitation of island-forming Volmer-Weber crystal growth is critical for growing large-area continuous thin films. Time-resolved photoluminescence, transient reflection spectroscopy, and electrical transport measurements show that the CsPbBr 3 epitaxial thin film has a slow charge carrier recombination rate, low surface recombination velocity (10 4 cm s -1 ), and low defect density of 10 12 cm -3 , which are comparable to those of CsPbBr 3 single crystals. This work suggests a general approach using oxide perovskites as substrates for heteroepitaxial growth of halide perovskites. The high-quality halide perovskite SCTFs epitaxially integrated with multifunctional oxide perovskites could open up opportunities for a variety of high-performance optoelectronics devices.

  12. One shot, one kill: the forces delivered by archer fish shots to distant targets.

    Science.gov (United States)

    Burnette, Morgan F; Ashley-Ross, Miriam A

    2015-10-01

    Archer fishes are skillful hunters of terrestrial prey, firing jets of water that dislodge insects perched on overhead vegetation. In the current investigation, we sought an answer to the question: are distant targets impractical foraging choices? Targets far from the shooter might not be hit with sufficient force to cause them to fall. However, observations from other investigators show that archer fish fire streams of water that travel in a non-ballistic fashion, which is thought to keep on-target forces high, even to targets that are several body lengths distant from the fish. We presented targets at different distances and investigated three aspects of foraging behavior: (i) on-target forces, (ii) shot velocity, (iii) a two-target choice assay to determine if fish would show any preference for downing closer targets or more distant targets. In general, shots from our fish (Toxotes chatareus) showed a mild decrease (less than 15% on average) in on-target forces at our most distant target offered (5.8 body lengths) with respect to the closest target offered (2.3 body lengths). One individual in our investigation showed slightly, but significantly, greater on-target forces as target distance increased. Forces on the furthest targets offered were found to double that of attachment forces for 200mg insects, even for individuals whose on-target forces showed mild decreases with increases in target distance. High-speed video analysis of jet impact with the target revealed that the shot was traveling in a non-ballistic manner, even to our most distant target offered, corroborating previous suppositions that on-target forces should remain high. Fish were able to accomplish this without large changes to shot velocity, but we did find evidence that the water jets appeared to differ in the timing of their acceleration as target distance increased. Our two-target choice experiment revealed that fish show preference for downing the closer target first, even though impact

  13. Preventive effect of shot peening on stress corrosion cracking

    International Nuclear Information System (INIS)

    Okido, Shinobu; Yoshimura, Toshihiko; Enomoto, Kunio; Saito, Hideyo; Morinaka, Ren; Ishikawa, Tetsuya

    2002-01-01

    The effect of shot peening (SP) on stress corrosion cracking (SCC) prevention was evaluated from the viewpoints of crack initiation and propagation. It was found that the residual stress in a Type-304 stainless-steel specimen is changed - from tensile of 300 MPa to compressive of -800 MPa - by shot peening, and the effective SP depth is 0.35 mm. It was also found that the crack initiation and propagation were prevented by shot peening. The mechanism by which the shot peening prevents these phenomena is explained according to the theory of superposition and loading history. That is, the prevention of crack initiation and propagation results from the fact that the compressive residual stress caused by SP decreases the applied load on the crack surface and prevents rupturing of the oxide film on the surface. Moreover, the effects of SCC prevention were shown to be valid when cyclic loading is applied after peening. (author)

  14. SunShot Vision Study: February 2012 (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2012-02-01

    The objective of the SunShot Vision Study is to provide an in-depth assessment of the potential for solar technologies to meet a significant share of electricity demand in the United States during the next several decades. Specifically, it explores a future in which the price of solar technologies declines by about 75% between 2010 and 2020 - in line with the U.S. Department of Energy (DOE) SunShot Initiative's targets.

  15. Biomechanical analysis of the jump shot in basketball.

    Science.gov (United States)

    Struzik, Artur; Pietraszewski, Bogdan; Zawadzki, Jerzy

    2014-09-29

    Basketball players usually score points during the game using the jump shot. For this reason, the jump shot is considered to be the most important element of technique in basketball and requires a high level of performance. The aim of this study was to compare the biomechanical characteristics of the lower limbs during a jump shot without the ball and a countermovement jump without an arm swing. The differences between variables provide information about the potential that an athlete can utilise during a game when performing a jump shot. The study was conducted among 20 second-league basketball players by means of a Kistler force plate and the BTS SMART system for motion analysis. The variables measured included the take-off time, mean power, peak power, relative mean power, jump height, maximum landing force and calculated impact ratio. Surprisingly, more advantageous variables were found for the jump shot. This finding suggests a very high performance level in the jump shot in the studied group and a maximum utilisation of their motor abilities. Both types of jumps were characterised by high mean and peak power values and average heights. The high forces at landing, which result in considerable impact ratios, may have prompted the studied group to land softly. Use of the countermovement jump without an arm swing is recommended to assess and predict the progression of player's jumping ability.

  16. Biomechanical Analysis of the Jump Shot in Basketball

    Directory of Open Access Journals (Sweden)

    Struzik Artur

    2014-10-01

    Full Text Available Basketball players usually score points during the game using the jump shot. For this reason, the jump shot is considered to be the most important element of technique in basketball and requires a high level of performance. The aim of this study was to compare the biomechanical characteristics of the lower limbs during a jump shot without the ball and a countermovement jump without an arm swing. The differences between variables provide information about the potential that an athlete can utilise during a game when performing a jump shot. The study was conducted among 20 second-league basketball players by means of a Kistler force plate and the BTS SMART system for motion analysis. The variables measured included the take-off time, mean power, peak power, relative mean power, jump height, maximum landing force and calculated impact ratio. Surprisingly, more advantageous variables were found for the jump shot. This finding suggests a very high performance level in the jump shot in the studied group and a maximum utilisation of their motor abilities. Both types of jumps were characterised by high mean and peak power values and average heights. The high forces at landing, which result in considerable impact ratios, may have prompted the studied group to land softly. Use of the countermovement jump without an arm swing is recommended to assess and predict the progression of player’s jumping ability

  17. Luminescence and origin of lead-related centers in single crystalline films of Y2SiO5 and Lu2SiO5

    International Nuclear Information System (INIS)

    Babin, V.; Gorbenko, V.; Krasnikov, A.; Mihokova, E.; Nikl, M.; Zazubovich, S.; Zorenko, Yu.

    2013-01-01

    In the temperature range 4.2–350 K, the steady-state and time-resolved emission and excitation spectra and luminescence decay kinetics are studied for the undoped Y 2 SiO 5 and Lu 2 SiO 5 single crystalline films grown by liquid phase epitaxy method from the PbO-based flux and, owing to that, containing lead ions substituting for Y 3+ or Lu 3+ ions. Luminescence characteristics of Pb-related centers of different types are identified. On the basis of the results obtained, we suggest that the ultraviolet emission of Pb-related centers arises from the Pb 2+ ions substituting for Y 3+ or Lu 3+ ions in the Y1 and Lu1 lattice sites of the X 2 structure. Possible hypotheses on the origin of the intense complex lead-related blue emission are discussed. We propose phenomenological models describing the excited-state dynamics of the studied luminescence centers. We also determine characteristic parameters of the corresponding relaxed excited states, in particular, the energy separations between the excited states and the rates of the radiative and non-radiative transitions from these states. -- Highlights: •Emission of lead centers in Y 2 SiO 5 and Lu 2 SiO 5 single crystalline films is studied. •The ultraviolet emission arises from Pb 2+ ions located in Y1 or Lu1 lattice sites. •Possible hypotheses on the origin of the blue emission are proposed and discussed. •The relaxed excited states parameters of various Pb-related centers are determined

  18. A Computationally Efficient Filter for Reducing Shot Noise in Low S/N Data.

    Directory of Open Access Journals (Sweden)

    Mami Okada

    Full Text Available Functional multineuron calcium imaging (fMCI provides a useful experimental platform to simultaneously capture the spatiotemporal patterns of neuronal activity from a large cell population in situ. However, fMCI often suffers from low signal-to-noise ratios (S/N. The main factor that causes the low S/N is shot noise that arises from photon detectors. Here, we propose a new denoising procedure, termed the Okada filter, which is designed to reduce shot noise under low S/N conditions, such as fMCI. The core idea of the Okada filter is to replace the fluorescence intensity value of a given frame time with the average of two values at the preceding and following frames unless the focused value is the median among these three values. This process is iterated serially throughout a time-series vector. In fMCI data of hippocampal neurons, the Okada filter rapidly reduces background noise and significantly improves the S/N. The Okada filter is also applicable for reducing shot noise in electrophysiological data and photographs. Finally, the Okada filter can be described using a single continuous differentiable equation based on the logistic function and is thus mathematically tractable.

  19. Demonstration of Shot-noise-limited Swept Source OCT Without Balanced Detection.

    Science.gov (United States)

    Fathipour, Vala; Schmoll, Tilman; Bonakdar, Alireza; Wheaton, Skylar; Mohseni, Hooman

    2017-04-26

    Optical coherence tomography (OCT) has been utilized in a rapidly growing number of clinical and scientific applications. In particular, swept source OCT (SS-OCT) has attracted many attentions due to its excellent performance. So far however, the limitations of existing photon detectors have prevented achieving shot-noise-limited sensitivity without using balanced-detection scheme in SS-OCT, even when superconducting single-photon detectors were used. Unfortunately, balanced-detection increases OCT system size and cost, as it requires many additional components to boost the laser power and maintain near ideal balanced performance across the whole optical bandwidth. Here we show for the first time that a photon detector is capable of achieving shot noise limited performance without using the balanced-detection technique in SS-OCT. We built a system using a so-called electron-injection photodetector, with a cutoff-wavelength of 1700 nm. Our system achieves a shot-noise-limited sensitivity of about -105 dB at a reference laser power of ~350 nW, which is more than 30 times lower laser power compared with the best-reported results. The high sensitivity of the electron-injection detector allows utilization of micron-scale tunable laser sources (e.g. VCSEL) and eliminates the need for fiber amplifiers and highly precise couplers, which are an essential part of the conventional SS-OCT systems.

  20. 77 FR 59158 - Migratory Bird Hunting; Application for Approval of Copper-Clad Iron Shot and Fluoropolymer Shot...

    Science.gov (United States)

    2012-09-26

    ... ``there is little variability in composition to be expected'' in production of the shot. Environ-Metal... the bulk of the coating. The pigments vary between coatings, and comprise 13.8% to 20.5% by weight of...

  1. The Effect of Introducing a Smaller and Lighter Basketball on Female Basketball Players’ Shot Accuracy

    Science.gov (United States)

    Podmenik, Nadja; Leskošek, Bojan; Erčulj, Frane

    2012-01-01

    Our study examined whether the introduction of a smaller and lighter basketball (no. 6) affected the accuracy of female basketball players’ shots at the basket. The International Basketball Federation (FIBA) introduced a size 6 ball in the 2004/2005 season to improve the efficiency and accuracy of technical elements, primarily shots at the basket. The sample for this study included 573 European female basketball players who were members of national teams that had qualified for the senior women’s European championships in 2001, 2003, 2005 and 2007. A size 7 (larger and heavier) basketball was used by 286 players in 1,870 matches, and a size 6 basketball was used by 287 players in 1,966 matches. The players were categorised into three playing positions: guards, forwards and centres. The results revealed that statistically significant changes by year occurred only in terms of the percentage of successful free throws. With the size 6 basketball, this percentage decreased. Statistically significant differences between the playing positions were observed in terms of the percentage of field goals worth three points (between guards and forwards) and two points (between guards and centres). The results show that the introduction of the size 6 basketball did not lead to improvement in shooting accuracy (the opposite was found for free throws), although the number of three-point shots increased. PMID:23486286

  2. Development of a Micro-shot Peening Process and Testing of Micro-shot Peened Engineering Materials

    OpenAIRE

    Vahey, James

    2006-01-01

    A precision, air blast, shot peening machine was designed and developed and used to carry out peening operations on engineering materials and components. The machine was designed to allow all the variables of the peening process to be controlled and adjusted. The micro-shot peening process was applied to a series of standard High Speed Steel twist drills, carbide inserts for milling cutters, turning tools and EPDM material. The drills were used under controlled CNC conditions to machine mild ...

  3. Influence of plasma molybdenizing and shot-peening on fretting damage behavior of titanium alloy

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Chang-bin, E-mail: tcbtop@126.com [School of Metallurgy and Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi 710055 (China); Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Liu, Dao-xin, E-mail: liudaox@nwpu.edu.cn [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Tang, Bin [Institute of Surface Engineering, Taiyuan University of Technology, Taiyuan Shanxi 030024 (China); Zhang, Xiao-hua [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China); Qin, Lin [Institute of Surface Engineering, Taiyuan University of Technology, Taiyuan Shanxi 030024 (China); Liu, Cheng-song [Institute of Corrosion and Protection, Northwestern Polytechnical University, Xi’an, Shaanxi 710072 (China)

    2016-12-30

    Highlights: • Plasma molybdenizing increases FW resistance of Ti6Al4V, but reduces its FF life. • Shot-peened plasmamolybdenizing surface enhances FW and FF resistance of Ti6Al4V. • Combined treatment yields low surface-roughness & high hardness gradient distribution. • Combined treatment yields beneficial residual compressive stress & good toughness. • Anti-wear & -fatigue performance improvements for surface engineering applications. - Abstract: Effect of plasma molybdenizing and shot-peening on fretting wear and fretting fatigue behaviors of Ti6Al4V alloy was investigated. The plasma molybdenized layer composed of a dense molybdenum deposition layer and a Mo–Ti solid–solution layer can increase surface hardness by 2.8 times and cause its volume loss by fretting wear to decrease to 1/14 compared with that of the substrate. Plasma molybdenized treatment results in a significant decrease in resistance of the substrate to fretting fatigue. It is ascribed that the molybdenized layer with high hardness yields a low toughness, and its high surface roughness leads to a micro-notched effect. However, proper combination plasma molybdenizing and subsequent shot-peening may enhance the simultaneous fretting fatigue and fretting wear resistance of Ti6Al4V significantly, which can decrease the fretting wear volume loss to 1/27, and may increase the fretting fatigue life by more than 69 times. A synergistic improvement in fretting fatigue of the titanium alloy by combining surface alloying with shot-peening can be achieved. The results indicate that a beneficial residual compressive stress distribution, high surface hardness with suitable hardness gradient distribution, good apparent toughness, relatively low surface roughness, and excellent surface integrity are achieved.

  4. Case report: Coccidiosis and lead poisoning in Canada geese

    Science.gov (United States)

    Locke, L.N.; Bagley, George E.

    1967-01-01

    Four dead Canada geese (Branta canadensis L.) collected at the Prime Hook National Wildlife Refuge, Delaware were found to have both marked duodenal lesions of coccidiosis and high levels of lead in the liver. Although only one goose had lead shot in the gizzard, all four had levels of lead in the liver suggestive of lead poisoning.

  5. Feasibility of one-shot-per-crystal structure determination using Laue diffraction

    International Nuclear Information System (INIS)

    Cornaby, Sterling; Szebenyi, Doletha M. E.; Smilgies, Detlef-M.; Schuller, David J.; Gillilan, Richard; Hao, Quan; Bilderback, Donald H.

    2010-01-01

    Structure determination was successfully carried out using single Laue exposures from a group of lysozyme crystals. The Laue method may be a viable option for collection of one-shot-per-crystal data from microcrystals. Crystal size is an important factor in determining the number of diffraction patterns which may be obtained from a protein crystal before severe radiation damage sets in. As crystal dimensions decrease this number is reduced, eventually falling to one, at which point a complete data set must be assembled using data from multiple crystals. When only a single exposure is to be collected from each crystal, the polychromatic Laue technique may be preferable to monochromatic methods owing to its simultaneous recording of a large number of fully recorded reflections per image. To assess the feasibility of solving structures using single Laue images from multiple crystals, data were collected using a ‘pink’ beam at the CHESS D1 station from groups of lysozyme crystals with dimensions of the order of 20–30 µm mounted on MicroMesh grids. Single-shot Laue data were used for structure determination by molecular replacement and correct solutions were obtained even when as few as five crystals were used

  6. Shot reproducibility of the self-magnetic-pinch diode at 4.5 MV

    OpenAIRE

    Nichelle Bennett; M. Dale Crain; Darryl W. Droemer; Raymond E. Gignac; Greg Lare; Isidro Molina; Robert Obregon; Chase C. Smith; Frank L. Wilkins; Dale R. Welch; Steve Cordova; Manuel L. Gallegos; Mark D. Johnston; Mark L. Kiefer; Joshua J. Leckbee

    2014-01-01

    In experiments conducted at Sandia National Laboratories’ RITS-6 accelerator, the self-magnetic-pinch diode exhibits significant shot-to-shot variability. Specifically, for identical hardware operated at the same voltage, some shots exhibit a catastrophic drop in diode impedance. A study is underway to identify sources of shot-to-shot variations which correlate with diode impedance collapse. The scope of this report is limited to data collected at 4.5-MV peak voltage and sources of variabilit...

  7. Numerical investigation of a shot peening process by a finite element approach

    DEFF Research Database (Denmark)

    Liu, Hongsheng; Zhang, Xiaodan; Hansen, Niels

    2014-01-01

    Shot peening is a surface impact treatment widely used to improve the performance of a metal or a component. The better performance of the shot peened part is controlled by compressive residual stresses resulting from the plastic deformation of the surface layers by impacts of shot. The compressi...... such as damping ratio of material, friction coefficient, shot velocity and shot angle on the magnitude and distribution of the compressive residual stress is examined....

  8. What can we learn about the dynamics of transported spins by measuring shot noise in spin–orbit-coupled nanostructures?

    International Nuclear Information System (INIS)

    Nikolić, Branislav K; Dragomirova, Ralitsa L

    2009-01-01

    We review recent studies of the shot noise of spin-polarized charge currents and pure spin currents in multiterminal semiconductor nanostructures, while focusing on the effects brought by the intrinsic Rashba spin–orbit (SO) coupling and/or extrinsic SO scattering off impurities in two-dimensional electron gas (2DEG) based devices. By generalizing the scattering theory of quantum shot noise to include the full spin-density matrix of electrons injected from a spin-filtering electrode, we show how decoherence and dephasing in the course of spin precession can lead to the substantial enhancement of the Fano factor (noise-to-current ratio) of spin-polarized charge currents. These processes are suppressed by decreasing the width of the diffusive Rashba wire, so that purely electrical measurement of the shot noise in a ferromagnet|SO-coupled-diffusive-wire|paramagnet setup can quantify the degree of quantum coherence of transported spin through a remarkable one-to-one correspondence between the purity of the spin state and the Fano factor. In four-terminal SO-coupled nanostructures, injection of unpolarized charge current through the longitudinal leads is responsible not only for the pure spin Hall current in the transverse leads, but also for nonequilibrium random time-dependent current fluctuations. The analysis of the shot noise of transverse pure spin Hall current and zero charge current, or transverse spin current and non-zero charge Hall current, driven by unpolarized or spin-polarized injected longitudinal charge current, respectively, reveals a unique experimental tool to differentiate between the intrinsic Rashba and extrinsic SO mechanisms underlying the spin Hall effect in 2DEG devices. When the intrinsic mechanisms responsible for spin precession start to dominate the spin Hall effect, they also enhance the shot noise of transverse spin and charge transport in multiterminal geometries. Finally, we discuss the shot noise of transverse spin and zero charge

  9. Progenitor strain introduction of Mycobacterium bovis at the wildlife-livestock interface can lead to clonal expansion of the disease in a single ecosystem

    KAUST Repository

    Dippenaar, Anzaan

    2017-04-13

    Mycobacterium bovis infects multiple wildlife species and domesticated cattle across South Africa, and negatively impacts on livestock trade and movement of wildlife for conservation purposes. M. bovis infection was first reported in the Kruger National Park (KNP) in South Africa during the 1990s, and has since spread to infect numerous animal host species throughout the park and across South Africa. Whole genome sequencing data of 17 M. bovis isolates were analyzed to investigate the genomic diversity among M. bovis isolates causing disease in different animal host species from various locations in South Africa. M. bovis strains analyzed in this study are geographic rather than host species-specific. The clonal expansion of M. bovis in the KNP highlights the effect of an introduction of a transmissible infectious disease leading to a rising epidemic in wildlife, and emphasizes the importance of disease control and movement restriction of species that serve as disease reservoirs. In conclusion, the point source introduction of a single M. bovis strain type in the KNP ecosystem lead to an M. bovis outbreak in this area that affects various host species and poses an infection risk in neighboring rural communities where HIV prevalence is high.

  10. Single Electron Transfer-Promoted Photochemical Reactions of Secondary N-Trimethylsilylmethyl-N-benzylamines Leading to Aminomethylation of Fullerene C60.

    Science.gov (United States)

    Lim, Suk Hyun; Jeong, Ho Cheol; Sohn, Youngku; Kim, Young-Il; Cho, Dae Won; Woo, Hee-Jae; Shin, Ik-Soo; Yoon, Ung Chan; Mariano, Patrick S

    2016-03-18

    Photoreactions between C60 and secondary N-trimethylsilylmethyl-N-benzylamines were explored to evaluate the feasibility of a new method for secondary aminomethylation of electron acceptors. The results show that photoreactions of C60 with these secondary amines in 10% EtOH-toluene occur to form aminomethyl-1,2-dihydrofullerenes predominantly through a pathway involving single electron transfer (SET)-promoted formation of secondary aminium radicals followed by preferential loss of the α-trimethylsilyl group. The aminomethyl radicals formed in this manner then couple with C60 or C60(•-) to form radical or anion precursors of the aminomethyl-1,2-dihydrofullerenes. In contrast to thermal and photochemical strategies developed previously, the new SET photochemical approach using α-trimethylsilyl-substituted secondary amines is both mild and efficient, and as a result, it should be useful in broadening the library of substituted fullerenes. Moreover, the results should have an impact on the design of SET-promoted C-C bond forming reactions. Specifically, introduction of an α-trimethylsilyl group leads to a change in the chemoselectivity of SET-promoted reactions of secondary amines with acceptors that typically favor aminium radical N-H deprotonation, leading to N-C bond formation. Finally, symmetric and unsymmetric fulleropyrrolidines are also generated in yields that are highly dependent on the electronic properties of arene ring substituents in amines, irradiation time, and solvent.

  11. Differential distributions for t-channel single top-quark production and decay at next-to-next-to-leading order in QCD

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Edmond L.; Gao, Jun; Zhu, Hua Xing

    2017-11-01

    We present a detailed phenomenological study of the next-to-next-to-leading order (NNLO) QCD corrections for t-channel single top (anti-)quark production and its semi-leptonic decay at the CERN Large Hadron Collider (LHC). We find the NNLO corrections for the total inclusive rates at the LHC with different center of mass energies are generally smaller than the NLO corrections, indicative of improved convergence. However, they can be large for differential distributions, reaching a level of 10% or more in certain regions of the transverse momentum distributions of the top (anti-)quark and the pseudo-rapidity distributions of the leading jet in the event. In all cases the perturbative hard-scale uncertainties are greatly reduced after the NNLO corrections are included. We also show a comparison of the normalized parton-level distributions to recent data from the 8 TeV measurement of the ATLAS collaboration. The NNLO corrections tend to shift the theoretical predictions closer to the measured transverse momentum distribution of the top (anti)-quark. Importantly, for the LHC at 13 TeV, we present NNLO cross sections in a fiducial volume with decays of the top quark included.

  12. Progenitor strain introduction of Mycobacterium bovis at the wildlife-livestock interface can lead to clonal expansion of the disease in a single ecosystem.

    Science.gov (United States)

    Dippenaar, Anzaan; Parsons, Sven David Charles; Miller, Michele Ann; Hlokwe, Tiny; Gey van Pittius, Nicolaas Claudius; Adroub, Sabir Abdu; Abdallah, Abdallah Musa; Pain, Arnab; Warren, Robin Mark; Michel, Anita Luise; van Helden, Paul David

    2017-07-01

    Mycobacterium bovis infects multiple wildlife species and domesticated cattle across South Africa, and negatively impacts on livestock trade and movement of wildlife for conservation purposes. M. bovis infection was first reported in the Kruger National Park (KNP) in South Africa during the 1990s, and has since spread to infect numerous animal host species throughout the park and across South Africa. Whole genome sequencing data of 17 M. bovis isolates were analyzed to investigate the genomic diversity among M. bovis isolates causing disease in different animal host species from various locations in South Africa. M. bovis strains analyzed in this study are geographic rather than host species-specific. The clonal expansion of M. bovis in the KNP highlights the effect of an introduction of a transmissible infectious disease leading to a rising epidemic in wildlife, and emphasizes the importance of disease control and movement restriction of species that serve as disease reservoirs. In conclusion, the point source introduction of a single M. bovis strain type in the KNP ecosystem lead to an M. bovis outbreak in this area that affects various host species and poses an infection risk in neighboring rural communities where HIV prevalence is high. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Effect of shot peening on metastable austenitic stainless steels

    International Nuclear Information System (INIS)

    Fargas, G.; Roa, J.J.; Mateo, A.

    2015-01-01

    In this work, shot peening was performed in a metastable austenitic stainless steel EN 1.4318 (AISI 301LN) in order to evaluate its effect on austenite to martensite phase transformation and also the influence on the fatigue limit. Two different steel conditions were considered: annealed, i.e., with a fully austenitic microstructure, and cold rolled, consisting of a mixture of austenite and martensite. X-ray diffraction, electron back-scattered diffraction and focus ion beam, as well as nanoindentation techniques, were used to elucidate deformation mechanisms activated during shot peening and correlate with fatigue response. Results pointed out that extensive plastic deformation and phase transformation developed in annealed specimens as a consequence of shot peening. However, the increase of roughness and the generation of microcracks led to a limited fatigue limit improvement. In contrast, shot peened cold rolled specimens exhibited enhanced fatigue limit. In the latter case, the main factor that determined the influence on the fatigue response was the distance from the injector, followed successively by the exit speed of the shots and the coverage factor

  14. INCREASED DISTANCE OF SHOOTING ON BASKETBALL JUMP SHOT

    Directory of Open Access Journals (Sweden)

    Victor Hugo Alves Okazaki

    2012-06-01

    Full Text Available The present study analyzed the effect of increased distance on basketball jump shot outcome and performance. Ten male expert basketball players were filmed and a number of kinematic variables analyzed during jump shot that were performed from three conditions to represent close, intermediate and far distances (2.8, 4.6, and 6.4m, respectively. Shot accuracy decreased from 59% (close to 37% (far, in function of the task constraints (p < 0.05. Ball release height decreased (p < 0.05 from 2.46 m (close to 2.38m (intermediate and to 2.33m (long. Release angle also decreased (p < 0.05 when shot was performed from close (78.92° in comparison to intermediate distances (65.60°. While, ball release velocity increased (p < 0.05 from 4.39 m/s (close to 5.75 m·s-1 (intermediate to 6.89 m·s-1 (far. These changes in ball release height, angle and velocity, related to movement performance adaptations were suggested as the main factors that influence jump shot accuracy when distance is augmented

  15. Determined Initial lead for South Of Isua (SOI) terrain suggests a single homogeneous source for it and possibly other archaean rocks

    Science.gov (United States)

    Tera, F.

    2011-12-01

    A Thorogenic-Uranogenic Lead Isotope Plane (TULIP), which entails plotting 206/208 (or its reverse) vs 207/208 (or its reverse), was applied to the Pb data on South of Isua (SOI) by Kamber et al., (1). When the data on 20 samples of these rocks and feldspars are plotted in pairs (each pair is a rock and its feldspar) on TULIP, they fall on 10 mixing lines that converge on a single spot (Fig. 1). This is the end member initial lead (EMIL). The 206/208 & 207/208 so determined are 0.3675 and 0.43525, respectively. From these values one calculates 207/206 = 1.1843 ± 0.0007, for EMIL. This pattern requires either: A) each pair has a singular kappa, K = 232Th/238U, different from others, or B) a pair's in situ decay Pb was homogenized in recent times. On 204/206 vs 207/206 diagram, the whole rocks of SOI define a 3.776 Ga isochron (2). From this and EMIL's 207/206, one obtains: 206/204 = 10.977, 207/204 = 12.974; and 208/204 = 29.756. This singularity of initial Pb contrasts with a deduced variability by the original authors (1). EMIL's radiogenic *(207/206) = 1.6220, gives a single-stage age = 5.9 Ga, indicating inapplicability of its evolution in one stage. Also, the μ calculated from 238U-206Pb for the single stage is different from that inferred from 235U-207Pb, confirming disqualification of this scenario. Reconciliation of the two decay schemes necessitates assumption of EMIL evolution in a minimum of two stages. Starting at 4.563 Ga, five scenarios were assumed: First stage ends and second starts at 4.55, 4.54, 4.53, 4.52 or 4.51 Ga. Second stages end at 3.776 Ga. The calculated μ1 for the first stage are 106, 59.5, 44.6, 36.3 and 30.9 respectively. For μ2 the change is limited, from 5.45 to 5.28. Only an average calculated K for both stages is possible. For the five outlined scenarios it ranges from 1.118 to 1.111. Earlier, Tera (3) observed that initial Pb of the oldest terrestrial reservoir requires evolution in two stages. There too μ1 >> μ2. Data on

  16. Release of copper from sintered tungsten-bronze shot under different pH conditions and its potential toxicity to aquatic organisms

    International Nuclear Information System (INIS)

    Thomas, Vernon G.; Santore, Robert C.; McGill, Ian

    2007-01-01

    Sintered tungsten-bronze is a new substitute for lead shot, and is about to be deposited in and around the wetlands of North America. This material contains copper in the alloyed form of bronze. This in vitro study was performed according to U.S. Fish and Wildlife Service criteria to determine the dissolution rate of copper from the shot, and to assess the toxic risk that it may present to aquatic organisms. The dissolution of copper from tungsten-bronze shot, pure copper shot, and glass beads was measured in a buffered, moderately hard, synthetic water of pH 5.5, 6.6, and 7.8 over a 28-day period. The dissolution of copper from both the control copper shot and the tungsten-bronze shot was affected significantly by the pH of the water and the duration of dissolution (all p values < 0.000). The rate of copper release from tungsten bronze shot was 30 to 50 times lower than that from the copper shot, depending on pH (p < 0.0000). The observed expected environmental concentration of copper released from tungsten-bronze shot after 28 days was 0.02 μg/L at pH 7.8, and 0.4 μg/L at pH 5.6, using a loading and exposure scenario specific in a U.S. Fish and Wildlife Service protocol. Ratio Quotient values derived from the highest EEC observed in this study (0.4 μg/L), and the copper toxic effect levels for all aquatic species listed in the U.S. Environmental Protection Agency ambient water quality criteria database, were all far less than the 0.1 criterion value. Given the conditions stipulated by the U.S. Fish and Wildlife Service and the U.S. Environmental Protection Agency, heavy loading from discharged tungsten-bronze shot would not pose a toxic risk to potable water, or to soil. Consequently, it would appear that no toxic risks to aquatic organisms will attend the use of tungsten-bronze shot of the approved composition. Given the likelihood that sintered tungsten-bronze of the same formula will be used for fishing weights, bullets, and wheel balance weights, it is

  17. Safety and efficacy of dual-lead thalamic deep brain stimulation for patients with treatment-refractory multiple sclerosis tremor: a single-centre, randomised, single-blind, pilot trial.

    Science.gov (United States)

    Oliveria, Seth F; Rodriguez, Ramon L; Bowers, Dawn; Kantor, Daniel; Hilliard, Justin D; Monari, Erin H; Scott, Bonnie M; Okun, Michael S; Foote, Kelly D

    2017-09-01

    Efficacy in previous studies of surgical treatments of refractory multiple sclerosis tremor using lesioning or deep brain stimulation (DBS) has been variable. The aim of this study was to investigate the safety and efficacy of dual-lead thalamic DBS (one targeting the ventralis intermedius-ventralis oralis posterior nucleus border [the VIM lead] and one targeting the ventralis oralis anterior-ventralis oralis posterior border [the VO lead]) for the treatment of multiple sclerosis tremor. We did a single centre, single-blind, prospective, randomised pilot trial at the University of Florida Center for Movement Disorders and Neurorestoration clinic (Gainesville, FL, USA). We recruited adult patients with a clinical diagnosis of multiple sclerosis tremor refractory to previous medical therapy. Before surgery to implant both leads, we randomly assigned patients (1:1) to receive 3 months of optimised single-lead DBS-either VIM or VO. We did the randomisation with a computer-generated sequence, using three blocks of four patients, and independent members of the Center did the assignment. Patients and all clinicians other than the DBS programming nurse were masked to the choice of lead. Patients underwent surgery 1 month after their baseline visit for implantation of the dual lead DBS system. A pulse generator and two extension cables were implanted in a second surgery 3-4 weeks later. Patients then received an initial 3-month period of continuous stimulation of either the VIM or VO lead followed by blinded safety assessment of their tremor with the Tolosa-Fahn-Marin Tremor Rating Scale (TRS) during optimised VIM or VO lead stimulation at the end of the 3 months. After this visit, both leads were activated in all patients for an additional 3 months, and optimally programmed during serial visits as dictated by a prespecified programming algorithm. At the 6-month follow-up visit, TRS score was measured, and mood and psychological batteries were administered under four

  18. Higher-order spin and charge dynamics in a quantum dot-lead hybrid system.

    Science.gov (United States)

    Otsuka, Tomohiro; Nakajima, Takashi; Delbecq, Matthieu R; Amaha, Shinichi; Yoneda, Jun; Takeda, Kenta; Allison, Giles; Stano, Peter; Noiri, Akito; Ito, Takumi; Loss, Daniel; Ludwig, Arne; Wieck, Andreas D; Tarucha, Seigo

    2017-09-22

    Understanding the dynamics of open quantum systems is important and challenging in basic physics and applications for quantum devices and quantum computing. Semiconductor quantum dots offer a good platform to explore the physics of open quantum systems because we can tune parameters including the coupling to the environment or leads. Here, we apply the fast single-shot measurement techniques from spin qubit experiments to explore the spin and charge dynamics due to tunnel coupling to a lead in a quantum dot-lead hybrid system. We experimentally observe both spin and charge time evolution via first- and second-order tunneling processes, and reveal the dynamics of the spin-flip through the intermediate state. These results enable and stimulate the exploration of spin dynamics in dot-lead hybrid systems, and may offer useful resources for spin manipulation and simulation of open quantum systems.

  19. Direct comparison of shot-to-shot noise performance of all normal dispersion and anomalous dispersion supercontinuum pumped with sub-picosecond pulse fiber-based laser

    Science.gov (United States)

    Klimczak, Mariusz; Soboń, Grzegorz; Kasztelanic, Rafał; Abramski, Krzysztof M.; Buczyński, Ryszard

    2016-01-01

    Coherence of supercontinuum sources is critical for applications involving characterization of ultrafast or rarely occurring phenomena. With the demonstrated spectral coverage of supercontinuum extending from near-infrared to over 10 μm in a single nonlinear fiber, there has been a clear push for the bandwidth rather than for attempting to optimize the dynamic properties of the generated spectrum. In this work we provide an experimental assessment of the shot-to-shot noise performance of supercontinuum generation in two types of soft glass photonic crystal fibers. Phase coherence and intensity fluctuations are compared for the cases of an anomalous dispersion-pumped fiber and an all-normal dispersion fiber. With the use of the dispersive Fourier transformation method, we demonstrate that a factor of 100 improvement in signal-to-noise ratio is achieved in the normal-dispersion over anomalous dispersion-pumped fiber for 390 fs long pump pulses. A double-clad design of the photonic lattice of the fiber is further postulated to enable a pump-related seeding mechanism of normal-dispersion supercontinuum broadening under sub-picosecond pumping, which is otherwise known for similar noise characteristics as modulation instability driven, soliton-based spectra. PMID:26759188

  20. Unsupervised Video Shot Detection Using Clustering Ensemble with a Color Global Scale-Invariant Feature Transform Descriptor

    Directory of Open Access Journals (Sweden)

    Yuchou Chang

    2008-02-01

    Full Text Available Scale-invariant feature transform (SIFT transforms a grayscale image into scale-invariant coordinates of local features that are invariant to image scale, rotation, and changing viewpoints. Because of its scale-invariant properties, SIFT has been successfully used for object recognition and content-based image retrieval. The biggest drawback of SIFT is that it uses only grayscale information and misses important visual information regarding color. In this paper, we present the development of a novel color feature extraction algorithm that addresses this problem, and we also propose a new clustering strategy using clustering ensembles for video shot detection. Based on Fibonacci lattice-quantization, we develop a novel color global scale-invariant feature transform (CGSIFT for better description of color contents in video frames for video shot detection. CGSIFT first quantizes a color image, representing it with a small number of color indices, and then uses SIFT to extract features from the quantized color index image. We also develop a new space description method using small image regions to represent global color features as the second step of CGSIFT. Clustering ensembles focusing on knowledge reuse are then applied to obtain better clustering results than using single clustering methods for video shot detection. Evaluation of the proposed feature extraction algorithm and the new clustering strategy using clustering ensembles reveals very promising results for video shot detection.

  1. Unsupervised Video Shot Detection Using Clustering Ensemble with a Color Global Scale-Invariant Feature Transform Descriptor

    Directory of Open Access Journals (Sweden)

    Hong Yi

    2008-01-01

    Full Text Available Abstract Scale-invariant feature transform (SIFT transforms a grayscale image into scale-invariant coordinates of local features that are invariant to image scale, rotation, and changing viewpoints. Because of its scale-invariant properties, SIFT has been successfully used for object recognition and content-based image retrieval. The biggest drawback of SIFT is that it uses only grayscale information and misses important visual information regarding color. In this paper, we present the development of a novel color feature extraction algorithm that addresses this problem, and we also propose a new clustering strategy using clustering ensembles for video shot detection. Based on Fibonacci lattice-quantization, we develop a novel color global scale-invariant feature transform (CGSIFT for better description of color contents in video frames for video shot detection. CGSIFT first quantizes a color image, representing it with a small number of color indices, and then uses SIFT to extract features from the quantized color index image. We also develop a new space description method using small image regions to represent global color features as the second step of CGSIFT. Clustering ensembles focusing on knowledge reuse are then applied to obtain better clustering results than using single clustering methods for video shot detection. Evaluation of the proposed feature extraction algorithm and the new clustering strategy using clustering ensembles reveals very promising results for video shot detection.

  2. The Effect of Multiple Shot Peening on the Corrosion Behavior of Duplex Stainless Steel

    Science.gov (United States)

    Feng, Qiang; She, Jia; Wu, Xueyan; Wang, Chengxi; Jiang, Chuanhai

    2018-03-01

    Various types of shot peening treatments were applied to duplex stainless steel. The effects of shot peening intensity and working procedures on the microstructure were investigated. The domain size and microstrain evolution in the surface layer were characterized utilizing the Rietveld method. As the shot peening intensity increased, the surface roughness increased in the surface layer; however, it decreased after multiple (dual and triple) shot peening. The mole fraction of strain-induced martensite as a function of the intensity of shot peening was evaluated by XRD measurements. Both potentiodynamic polarization curves and salt spray tests of shot-peened samples in NaCl solution were investigated. The results indicate that traditional shot peening has negative effects on corrosion resistance with increasing shot peening intensity; however, the corrosion rate can be reduced by means of multiple shot peening.

  3. Superpoissonian shot noise in organic magnetic tunnel junctions

    Energy Technology Data Exchange (ETDEWEB)

    Cascales, Juan Pedro; Martinez, Isidoro; Aliev, Farkhad G., E-mail: farkhad.aliev@uam.es [Dpto. Fisica Materia Condensada C3, Instituto Nicolas Cabrera (INC), Condensed Matter Physics Institute (IFIMAC), Universidad Autonoma de Madrid, Madrid 28049 (Spain); Hong, Jhen-Yong; Lin, Minn-Tsong, E-mail: mtlin@phys.ntu.edu.tw [Department of Physics, National Taiwan University, Taipei 10617, Taiwan and Institute of Atomic and Molecular Sciences, Academia Sinica, Taipei 10617, Taiwan (China); Szczepański, Tomasz; Dugaev, Vitalii K. [Department of Physics, Rzeszów University of Technology, al. Powstańców Warszawy 6, 35-959 Rzeszów (Poland); Barnaś, Józef [Faculty of Physics, Adam Mickiewicz University, ul. Umultowska 85, 61-614 Poznań, Poland and Institute of Molecular Physics, Polish Academy of Sciences, ul. Smoluchowskiego 17, 60-179 Poznań (Poland)

    2014-12-08

    Organic molecules have recently revolutionized ways to create new spintronic devices. Despite intense studies, the statistics of tunneling electrons through organic barriers remains unclear. Here, we investigate conductance and shot noise in magnetic tunnel junctions with 3,4,9,10-perylene-teracarboxylic dianhydride (PTCDA) barriers a few nm thick. For junctions in the electron tunneling regime, with magnetoresistance ratios between 10% and 40%, we observe superpoissonian shot noise. The Fano factor exceeds in 1.5–2 times the maximum values reported for magnetic tunnel junctions with inorganic barriers, indicating spin dependent bunching in tunneling. We explain our main findings in terms of a model which includes tunneling through a two level (or multilevel) system, originated from interfacial bonds of the PTCDA molecules. Our results suggest that interfaces play an important role in the control of shot noise when electrons tunnel through organic barriers.

  4. Observability of radiation-pressure shot noise in optomechanical systems

    International Nuclear Information System (INIS)

    Boerkje, K.; Nunnenkamp, A.; Zwickl, B. M.; Yang, C.; Harris, J. G. E.; Girvin, S. M.

    2010-01-01

    We present a theoretical study of an experiment designed to detect radiation-pressure shot noise in an optomechanical system. Our model consists of a coherently driven optical cavity mode that is coupled to a mechanical oscillator. We examine the cross-correlation between two quadratures of the output field from the cavity. We determine under which circumstances radiation-pressure shot noise can be detected by a measurement of this cross-correlation. This is done in the general case of nonzero detuning between the frequency of the drive and the cavity resonance frequency. We study the qualitative features of the different contributions to the cross-correlator and provide quantitative figures of merit for the relative importance of the radiation-pressure shot noise contribution to other contributions. We also propose a modified setup of this experiment relevant to the 'membrane-in-the-middle' geometry, which potentially can avoid the problems of static bistability and classical noise in the drive.

  5. Analysis of shot-to-shot variability in post-disruption runaway electron currents for diverted DIII-D discharges

    International Nuclear Information System (INIS)

    Izzo, V A; Humphreys, D A; Kornbluth, M

    2012-01-01

    In DIII-D experiments, rapid termination by Ar-pellet injection sometimes produces a post-termination runaway electron (RE) current plateau, but this effect is highly non-reproducible on a shot-to-shot basis, particularly for diverted target plasmas. A set of DIII-D discharges is analyzed with two MHD codes to understand the relationship between the current profile of the target plasma and the amplitude of the RE current plateau. Using the linear stability code GATO, a correlation between the radial profile of the unstable n = 1 mode just after Ar-pellet injection and the observed appearance of an RE plateau is identified. Nonlinear NIMROD simulations with RE test-particle calculations directly predict RE confinement times during the disruption. With one exception, NIMROD predicts better RE confinement for shots in which higher RE currents were observed in DIII-D. But, the variation in confinement is primarily connected to the saturated n = 1 mode amplitude and not its radial profile. Still, both sets of analyses support the hypothesis that RE deconfinement by MHD fluctuations is a major factor in the shot-to-shot variability of RE plateaus, though additional factors such as seed current amplitude cannot be ruled out. (paper)

  6. Analysis of shot-to-shot variability in post-disruption runaway electron currents for diverted DIII-D discharges

    Science.gov (United States)

    Izzo, V. A.; Humphreys, D. A.; Kornbluth, M.

    2012-09-01

    In DIII-D experiments, rapid termination by Ar-pellet injection sometimes produces a post-termination runaway electron (RE) current plateau, but this effect is highly non-reproducible on a shot-to-shot basis, particularly for diverted target plasmas. A set of DIII-D discharges is analyzed with two MHD codes to understand the relationship between the current profile of the target plasma and the amplitude of the RE current plateau. Using the linear stability code GATO, a correlation between the radial profile of the unstable n = 1 mode just after Ar-pellet injection and the observed appearance of an RE plateau is identified. Nonlinear NIMROD simulations with RE test-particle calculations directly predict RE confinement times during the disruption. With one exception, NIMROD predicts better RE confinement for shots in which higher RE currents were observed in DIII-D. But, the variation in confinement is primarily connected to the saturated n = 1 mode amplitude and not its radial profile. Still, both sets of analyses support the hypothesis that RE deconfinement by MHD fluctuations is a major factor in the shot-to-shot variability of RE plateaus, though additional factors such as seed current amplitude cannot be ruled out.

  7. Superhydrophobic Copper Surfaces by Shot Peening and Chemical Treatment

    Science.gov (United States)

    Forooshani, H. Mojiri; Aliofkhazraei, M.; Rouhaghdam, A. Sabour

    In this paper, superhydrophobic surfaces are developed on polycrystalline copper using a combination of mechanical and chemical treatments by shot peening, dislocation etching and stearic acid treatment. The key point in this combined approach is the fabrication of a dislocation forest by shot peening. These sites were dissolved by etching, and hierarchical structures were fabricated. When these etched surfaces are treated by stearic acid, which has low surface energy, they become superhydrophobic with contact angle more than 150∘. Because of the superior properties and low costs involved with this method, it is expected to be widely used in the industry to fabricate superhydrophobic surfaces.

  8. Effect of shot peening on steam generator tube cracking risks

    International Nuclear Information System (INIS)

    Lannoy, A.

    1993-01-01

    One of the main SG tube degradation modes in stress corrosion cracking on the primary side in the tube/tube plate roll transition zone. With a view to mitigating these cracking risks, on the 900 MWe PWR's plant, the SG inner tube walls were mechanically stress-relieved by shot peening. Between 1985 and 1988, periodic eddy current testing were performed during refuelling outages before and after the shot peening that allows to monitor the number and condition of affected tubes versus time in service. Statistical analysis were performed in order to test and quantify the effects of this treatment. (author). 3 figs., 2 refs

  9. Preparation of Ultracold Atom Clouds at the Shot Noise Level

    DEFF Research Database (Denmark)

    Gajdacz, M.; Hilliard, A. J.; Kristensen, Mick

    2016-01-01

    We prepare number stabilized ultracold atom clouds through the real-time analysis of nondestructive images and the application of feedback. In our experiments, the atom number N∼10^6 is determined by high precision Faraday imaging with uncertainty ΔN below the shot noise level, i.e., ΔN... on this measurement, feedback is applied to reduce the atom number to a user-defined target, whereupon a second imaging series probes the number stabilized cloud. By this method, we show that the atom number in ultracold clouds can be prepared below the shot noise level....

  10. Gas-Bearing Crucible for Shot Tower

    Science.gov (United States)

    Youngberg, C. L.; Miller, C. G.; Stephens, J. B.; Finnerty, A. A.

    1983-01-01

    Device protects molten drops from contamination and distortion. Gas flowing through levitator tube levitates small balls while they melt. Gas heated by filament extending through center of tube. Gas bearing crucible on tube has concave configuration to hold single relatively large ball or many recesses to hold many small balls. By time spheres reach foam, they are cooled sufficiently by radiation to retain their shape.

  11. Evaluation of an algorithm based on single-condition decision rules for binary classification of 12-lead ambulatory ECG recording quality

    International Nuclear Information System (INIS)

    Di Marco, Luigi Yuri; Duan, Wenfeng; Bojarnejad, Marjan; Zheng, Dingchang; Murray, Alan; Langley, Philip; King, Susan

    2012-01-01

    A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on individual leads from joint time-frequency analysis and QRS amplitude. Classification was based on cascaded single-condition decision rules (SCDR) that tested levels of contaminants against classification thresholds. A supervised learning classifier (SLC) was implemented for comparison. The SCDR and SLC algorithms were trained on an annotated database (Set A, PhysioNet Challenge 2011) of ‘acceptable’ versus ‘unacceptable’ quality recordings using the ‘leave M out’ approach with repeated random partitioning and cross-validation. Two training approaches were considered: (i) balanced, in which training records had equal numbers of ‘acceptable’ and ‘unacceptable’ recordings, (ii) unbalanced, in which the ratio of ‘acceptable’ to ‘unacceptable’ recordings from Set A was preserved. For each training approach, thresholds were calculated, and classification accuracy of the algorithm compared to other rule based algorithms and the SLC using a database for which classifications were unknown (Set B PhysioNet Challenge 2011). The SCDR algorithm achieved the highest accuracy (91.40%) compared to the SLC (90.40%) in spite of its simple logic. It also offers the advantage that it facilitates reporting of meaningful causes of poor signal quality to users. (paper)

  12. Evaluation of an algorithm based on single-condition decision rules for binary classification of 12-lead ambulatory ECG recording quality.

    Science.gov (United States)

    Di Marco, Luigi Yuri; Duan, Wenfeng; Bojarnejad, Marjan; Zheng, Dingchang; King, Susan; Murray, Alan; Langley, Philip

    2012-09-01

    A new algorithm for classifying ECG recording quality based on the detection of commonly observed ECG contaminants which often render the ECG unusable for diagnostic purposes was evaluated. Contaminants (baseline drift, flat line, QRS-artefact, spurious spikes, amplitude stepwise changes, noise) were detected on individual leads from joint time-frequency analysis and QRS amplitude. Classification was based on cascaded single-condition decision rules (SCDR) that tested levels of contaminants against classification thresholds. A supervised learning classifier (SLC) was implemented for comparison. The SCDR and SLC algorithms were trained on an annotated database (Set A, PhysioNet Challenge 2011) of 'acceptable' versus 'unacceptable' quality recordings using the 'leave M out' approach with repeated random partitioning and cross-validation. Two training approaches were considered: (i) balanced, in which training records had equal numbers of 'acceptable' and 'unacceptable' recordings, (ii) unbalanced, in which the ratio of 'acceptable' to 'unacceptable' recordings from Set A was preserved. For each training approach, thresholds were calculated, and classification accuracy of the algorithm compared to other rule based algorithms and the SLC using a database for which classifications were unknown (Set B PhysioNet Challenge 2011). The SCDR algorithm achieved the highest accuracy (91.40%) compared to the SLC (90.40%) in spite of its simple logic. It also offers the advantage that it facilitates reporting of meaningful causes of poor signal quality to users.

  13. Linking cases of illegal shootings of the endangered California condor using stable lead isotope analysis

    Energy Technology Data Exchange (ETDEWEB)

    Finkelstein, Myra E., E-mail: myraf@ucsc.edu [Microbiology and Environmental Toxicology Department, University of California, Santa Cruz, CA 95064 (United States); Kuspa, Zeka E. [Microbiology and Environmental Toxicology Department, University of California, Santa Cruz, CA 95064 (United States); Welch, Alacia [National Park Service, Pinnacles National Park, 5000 Highway 146, Paicines, CA 95043 (United States); Eng, Curtis; Clark, Michael [Los Angeles Zoo and Botanical Gardens, 5333 Zoo Drive, Los Angeles, CA 90027 (United States); Burnett, Joseph [Ventana Wildlife Society, 19045 Portola Dr. Ste. F-1, Salinas, CA 93908 (United States); Smith, Donald R. [Microbiology and Environmental Toxicology Department, University of California, Santa Cruz, CA 95064 (United States)

    2014-10-15

    Lead poisoning is preventing the recovery of the critically endangered California condor (Gymnogyps californianus) and lead isotope analyses have demonstrated that ingestion of spent lead ammunition is the principal source of lead poisoning in condors. Over an 8 month period in 2009, three lead-poisoned condors were independently presented with birdshot embedded in their tissues, evidencing they had been shot. No information connecting these illegal shooting events existed and the timing of the shooting(s) was unknown. Using lead concentration and stable lead isotope analyses of feathers, blood, and recovered birdshot, we observed that: i) lead isotope ratios of embedded shot from all three birds were measurably indistinguishable from each other, suggesting a common source; ii) lead exposure histories re-constructed from feather analysis suggested that the shooting(s) occurred within the same timeframe; and iii) two of the three condors were lead poisoned from a lead source isotopically indistinguishable from the embedded birdshot, implicating ingestion of this type of birdshot as the source of poisoning. One of the condors was subsequently lead poisoned the following year from ingestion of a lead buckshot (blood lead 556 µg/dL), illustrating that ingested shot possess a substantially greater lead poisoning risk compared to embedded shot retained in tissue (blood lead ∼20 µg/dL). To our knowledge, this is the first study to use lead isotopes as a tool to retrospectively link wildlife shooting events. - Highlights: • We conducted a case-based analysis of illegal shootings of California condors. • Blood and feather Pb isotopes were used to reconstruct the illegal shooting events. • Embedded birdshot from the three condors had the same Pb isotope ratios. • Feather and blood Pb isotopes indicated that the condors were shot in a common event. • Ingested shot causes substantially greater lead exposure compared to embedded shot.

  14. Multivariate Product-Shot-noise Cox Point Process Models

    DEFF Research Database (Denmark)

    Jalilian, Abdollah; Guan, Yongtao; Mateu, Jorge

    We introduce a new multivariate product-shot-noise Cox process which is useful for model- ing multi-species spatial point patterns with clustering intra-specific interactions and neutral, negative or positive inter-specific interactions. The auto and cross pair correlation functions of the process...

  15. One-shot valve may be remotely actuated

    Science.gov (United States)

    Kami, S.

    1965-01-01

    One-shot valve, with spring-loaded plunger and sealing diaphragm, incorporates an emergency release actuated by a remote sensor. The plunger is released by the electrical melting of a fuse link and pierces the valve seal. The valve lowers fluid pressure in a container without losing the contained fluid.

  16. SnapShot: Visualization to Propel Ice Hockey Analytics.

    Science.gov (United States)

    Pileggi, H; Stolper, C D; Boyle, J M; Stasko, J T

    2012-12-01

    Sports analysts live in a world of dynamic games flattened into tables of numbers, divorced from the rinks, pitches, and courts where they were generated. Currently, these professional analysts use R, Stata, SAS, and other statistical software packages for uncovering insights from game data. Quantitative sports consultants seek a competitive advantage both for their clients and for themselves as analytics becomes increasingly valued by teams, clubs, and squads. In order for the information visualization community to support the members of this blossoming industry, it must recognize where and how visualization can enhance the existing analytical workflow. In this paper, we identify three primary stages of today's sports analyst's routine where visualization can be beneficially integrated: 1) exploring a dataspace; 2) sharing hypotheses with internal colleagues; and 3) communicating findings to stakeholders.Working closely with professional ice hockey analysts, we designed and built SnapShot, a system to integrate visualization into the hockey intelligence gathering process. SnapShot employs a variety of information visualization techniques to display shot data, yet given the importance of a specific hockey statistic, shot length, we introduce a technique, the radial heat map. Through a user study, we received encouraging feedback from several professional analysts, both independent consultants and professional team personnel.

  17. Assessment for One-Shot Library Instruction: A Conceptual Approach

    Science.gov (United States)

    Wang, Rui

    2016-01-01

    The purpose of this study is to explore a conceptual approach to assessment for one-shot library instruction. This study develops a new assessment instrument based on Carol Kuhlthau's information search process (ISP) model. The new instrument focuses on measuring and identifying changes in student readiness to do research along three…

  18. ON THE USE OF SHOT NOISE FOR PHOTON COUNTING

    International Nuclear Information System (INIS)

    Zmuidzinas, Jonas

    2015-01-01

    Lieu et al. have recently claimed that it is possible to substantially improve the sensitivity of radio-astronomical observations. In essence, their proposal is to make use of the intensity of the photon shot noise as a measure of the photon arrival rate. Lieu et al. provide a detailed quantum-mechanical calculation of a proposed measurement scheme that uses two detectors and conclude that this scheme avoids the sensitivity degradation that is associated with photon bunching. If correct, this result could have a profound impact on radio astronomy. Here I present a detailed analysis of the sensitivity attainable using shot-noise measurement schemes that use either one or two detectors, and demonstrate that neither scheme can avoid the photon bunching penalty. I perform both semiclassical and fully quantum calculations of the sensitivity, obtaining consistent results, and provide a formal proof of the equivalence of these two approaches. These direct calculations are furthermore shown to be consistent with an indirect argument based on a correlation method that establishes an independent limit to the sensitivity of shot-noise measurement schemes. Furthermore, these calculations are directly applicable to the regime of interest identified by Lieu et al. Collectively, these results conclusively demonstrate that the photon-bunching sensitivity penalty applies to shot-noise measurement schemes just as it does to ordinary photon counting, in contradiction to the fundamental claim made by Lieu et al. The source of this contradiction is traced to a logical fallacy in their argument

  19. SunShot Catalyst Prize Competition Fact Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Solar Energy Technologies Office

    2015-04-01

    This fact sheet is an overview of the Catalyst Energy Innovation Prize, an open innovation program launched in 2014 by the U.S. Department of Energy SunShot Initiative. This program aims to catalyze the rapid creation and development of products and solutions that address near-term challenges in the U.S. solar energy marketplace.

  20. Flu Shots, Mammogram, and the Perception of Probabilities

    NARCIS (Netherlands)

    Carman, K.G.; Kooreman, P.

    2010-01-01

    We study individuals’ decisions to decline or accept preventive health care interventions such as flu shots and mammograms. In particular, we analyze the role of perceptions of the effectiveness of the intervention, by eliciting individuals' subjective probabilities of sickness and survival, with

  1. SnapShot: O-Glycosylation Pathways across Kingdoms

    DEFF Research Database (Denmark)

    Joshi, Hiren J.; Narimatsu, Yoshiki; Schjoldager, Katrine T.

    2018-01-01

    O-glycosylation is one of the most abundant and diverse types of post-translational modifications of proteins. O-glycans modulate the structure, stability, and function of proteins and serve generalized as well as highly specific roles in most biological processes. This ShapShot presents types of......-glycans found in different organisms and their principle biosynthetic pathways...

  2. DOE SunShot System Integration Program. Accomplishments and Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Boynton, Shannon [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ellis, Abraham [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-02-01

    During FY15, Sandia National Laboratories executed research and development (R&D) work on a portfolio of 16 SunShot Program Systems Integration (SI) agreements, with a total FY15 budget of $13.2 million. This document summarizes the impact of the Sandia contributions based on Sandia’s direct contributions by DOE.

  3. Gaze Embeddings for Zero-Shot Image Classification

    NARCIS (Netherlands)

    Karessli, N.; Akata, Z.; Schiele, B.; Bulling, A.

    2017-01-01

    Zero-shot image classification using auxiliary information, such as attributes describing discriminative object properties, requires time-consuming annotation by domain experts. We instead propose a method that relies on human gaze as auxiliary information, exploiting that even non-expert users have

  4. Movement symmetry and asymmetry of goal shots in female football ...

    African Journals Online (AJOL)

    This study examined the phenomenon of symmetrical skills in goal shot technique in female football players, of nine video recorded matches. The recording was taken during the 2nd Under 19 female football World Cup in 2004 and the 6th European female Championships of female seniors in 2005. The study comprised ...

  5. LEADING WITH LEADING INDICATORS

    International Nuclear Information System (INIS)

    PREVETTE, S.S.

    2005-01-01

    This paper documents Fluor Hanford's use of Leading Indicators, management leadership, and statistical methodology in order to improve safe performance of work. By applying these methods, Fluor Hanford achieved a significant reduction in injury rates in 2003 and 2004, and the improvement continues today. The integration of data, leadership, and teamwork pays off with improved safety performance and credibility with the customer. The use of Statistical Process Control, Pareto Charts, and Systems Thinking and their effect on management decisions and employee involvement are discussed. Included are practical examples of choosing leading indicators. A statistically based color coded dashboard presentation system methodology is provided. These tools, management theories and methods, coupled with involved leadership and employee efforts, directly led to significant improvements in worker safety and health, and environmental protection and restoration at one of the nation's largest nuclear cleanup sites

  6. The reliability and internal consistency of one-shot and flicker change detection for measuring individual differences in visual working memory capacity.

    Science.gov (United States)

    Pailian, Hrag; Halberda, Justin

    2015-04-01

    We investigated the psychometric properties of the one-shot change detection task for estimating visual working memory (VWM) storage capacity-and also introduced and tested an alternative flicker change detection task for estimating these limits. In three experiments, we found that the one-shot whole-display task returns estimates of VWM storage capacity (K) that are unreliable across set sizes-suggesting that the whole-display task is measuring different things at different set sizes. In two additional experiments, we found that the one-shot single-probe variant shows improvements in the reliability and consistency of K estimates. In another additional experiment, we found that a one-shot whole-display-with-click task (requiring target localization) also showed improvements in reliability and consistency. The latter results suggest that the one-shot task can return reliable and consistent estimates of VWM storage capacity (K), and they highlight the possibility that the requirement to localize the changed target is what engenders this enhancement. Through a final series of four experiments, we introduced and tested an alternative flicker change detection method that also requires the observer to localize the changing target and that generates, from response times, an estimate of VWM storage capacity (K). We found that estimates of K from the flicker task correlated with estimates from the traditional one-shot task and also had high reliability and consistency. We highlight the flicker method's ability to estimate executive functions as well as VWM storage capacity, and discuss the potential for measuring multiple abilities with the one-shot and flicker tasks.

  7. Interactive exploration of surveillance video through action shot summarization and trajectory visualization.

    Science.gov (United States)

    Meghdadi, Amir H; Irani, Pourang

    2013-12-01

    We propose a novel video visual analytics system for interactive exploration of surveillance video data. Our approach consists of providing analysts with various views of information related to moving objects in a video. To do this we first extract each object's movement path. We visualize each movement by (a) creating a single action shot image (a still image that coalesces multiple frames), (b) plotting its trajectory in a space-time cube and (c) displaying an overall timeline view of all the movements. The action shots provide a still view of the moving object while the path view presents movement properties such as speed and location. We also provide tools for spatial and temporal filtering based on regions of interest. This allows analysts to filter out large amounts of movement activities while the action shot representation summarizes the content of each movement. We incorporated this multi-part visual representation of moving objects in sViSIT, a tool to facilitate browsing through the video content by interactive querying and retrieval of data. Based on our interaction with security personnel who routinely interact with surveillance video data, we identified some of the most common tasks performed. This resulted in designing a user study to measure time-to-completion of the various tasks. These generally required searching for specific events of interest (targets) in videos. Fourteen different tasks were designed and a total of 120 min of surveillance video were recorded (indoor and outdoor locations recording movements of people and vehicles). The time-to-completion of these tasks were compared against a manual fast forward video browsing guided with movement detection. We demonstrate how our system can facilitate lengthy video exploration and significantly reduce browsing time to find events of interest. Reports from expert users identify positive aspects of our approach which we summarize in our recommendations for future video visual analytics systems.

  8. δ-Aminolevulinic Acid Dehydratase Single Nucleotide Polymorphism 2 and Peptide Transporter 2*2 Haplotype May Differentially Mediate Lead Exposure in Male Children

    Science.gov (United States)

    Parisi, Natali; Schaub, Tanner; Gutierrez, Marisela; Ortega, Alma X.

    2011-01-01

    Child low-level lead (Pb) exposure is an unresolved public health problem and an unaddressed child health disparity. Particularly in cases of low-level exposure, source removal can be impossible to accomplish, and the only practical strategy for reducing risk may be primary prevention. Genetic biomarkers of increased neurotoxic risk could help to identify small subgroups of children for early intervention. Previous studies have suggested that, by way of a distinct mechanism, δ-aminolevulinic acid dehydratase single nucleotide polymorphism 2 (ALAD2) and/or peptide transporter 2*2 haplotype (hPEPT2*2) increase Pb blood burden in children. Studies have not yet examined whether sex mediates the effects of genotype on blood Pb burden. Also, previous studies have not included blood iron (Fe) level in their analyses. Blood and cheek cell samples were obtained from 306 minority children, ages 5.1 to 12.9 years. 208Pb and 56Fe levels were determined with inductively coupled plasma–mass spectrometry. General linear model analyses were used to examine differences in Pb blood burden by genotype and sex while controlling for blood Fe level. The sample geometric mean Pb level was 2.75 µg/dl. Pb blood burden was differentially higher in ALAD2 heterozygous boys and hPEPT2*2 homozygous boys. These results suggest that the effect of ALAD2 and hPEPT2*2 on Pb blood burden may be sexually dimorphic. ALAD2 and hPEPT2*2 may be novel biomarkers of health and mental health risks in male children exposed to low levels of Pb. PMID:21327641

  9. Reader Perception of Newspaper Mug Shot Subjects in Photos and in Stories.

    Science.gov (United States)

    Lain, Laurence B.

    A study investigated whether newspaper mug shots are perceived by readers as being positive or negative in tone and whether the mug shots that are selected match the roles of their subjects in accompanying stories. Twenty-three news and feature stories with associated mug shots were clipped from seven daily newspapers. Pictures and stories were…

  10. Movement Analysis Applied to the Basketball Jump Shot--Part II.

    Science.gov (United States)

    Martin, Thomas P.

    1981-01-01

    The jump shot is one of the most important shots in the game of basketball. The movement analysis of the jump shot designates four phases: (1) preparatory position; (2) movement phase I (crouch); (3) movement phase II (jump); and (4) follow-through. (JN)

  11. An investigation of the properties of conventional and severe shot peened low alloy steel

    Science.gov (United States)

    Quang Trung, Pham; Butler, David Lee; Win Khun, Nay

    2017-07-01

    The effects of the conventional shot peening and severe shot peening process on the mechanical and tribological properties of shot peened AISI 4340 high strength steel were systematically investigated. Compared with the conventional shot peened sample, the ultrafine grain surface layer with a depth of about 20 µm generated by the severe shot peening process can enhance the hardness and wear resistance of the treated material. However, deeper dimples generated by the high media velocity in the severe shot peening process resulted in a higher surface roughness, which is considered as a side effect of this method reducing the fatigue life of the material. Applying a smaller shot size with an appropriate intensity can be used to peen the severe shot peened samples to not only reduce the surface roughness and friction coefficient but also improve the wear resistance for these samples. This work was presented in the shot peening section during ‘The 30th International Conference on Surface Modification Technologies, 2016, Milan, Italy’ (SMT30, ID 61, entitled ‘Comparison of the effects of conventional shot peening and severe shot peening processes on the mechanical and tribological properties of shot peened AISI 4340’) and the authors were encouraged to submit a manuscript to the Materials Research Express journal after adding some nessesary information.

  12. Chronic Lead Intoxication From Eating Wild-Harvested Game.

    Science.gov (United States)

    Buenz, Eric J; Parry, Gareth J

    2017-12-13

    The purpose of this article is to determine if conversion from eating wild game harvested with lead-based ammunition to nonlead-based ammunition results in lower blood lead levels. Supersonic injection of toxin-leeching frangible projectiles into food is intuitively bad. As much as 95% of the ~13.7 million hunters in the United States choose shrapnel-inducing lead bullets to kill game; in addition, not harvesting meat is an incarcerable crime. A lead ammunition ban on certain federal lands was recently rescinded and the National Rifle Association refutes any risk from eating lead bullet-harvested game. A patient subsisting solely on lead-shot meat was converted to non-lead ammunition and his blood lead level tracked. Concomitant with his conversion to nonlead ammunition, a controlled experiment was performed using the patient's bullets to determine his daily lead intake from lead-shot meat. While eating lead-shot meat, the patient was consuming 259.3 ± 235.6 µg of lead daily and his blood lead level was 74.7 µg/dL. Conversion to nonlead ammunition was associated with a reduced blood lead level. Unsafe blood lead levels can occur from eating game harvested with lead ammunition. Physicians should warn hunting patients of this potential risk and counsel them about the availability of nonlead ammunition alternatives. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. shot regulates the microtubule reorganization required for localization of axis-determining mRNAs during oogenesis.

    Science.gov (United States)

    Lee, Jiyeon; Lee, Sujung; Chen, Cheng; Shim, Hyeran; Kim-Ha, Jeongsil

    2016-02-01

    The Drosophila mid-oogenesis stages are notable as the time when most maternal mRNAs become localized at discrete regions of the oocyte. Microtubule rearrangement occurs during this period and is critical for the localization of axis-determining maternal mRNAs. We have identified shot as a key player in establishing the cytoskeletal arrangement required for the spatial localization of axis-determining maternal mRNAs. We also found that the spatial distribution of the Shot protein is regulated by its mRNA localization. Our results suggest that the RNA localization mechanism is used not only for restricted accumulation of patterning molecules but also for the microtubule organization that leads to the initial development of oocyte polarity. © 2016 Federation of European Biochemical Societies.

  14. Incidence and predictors of clinically relevant cardiac perforation associated with systematic implantation of active-fixation pacing and defibrillation leads: a single-centre experience with over 3800 implanted leads.

    Science.gov (United States)

    Cano, Óscar; Andrés, Ana; Alonso, Pau; Osca, Joaquín; Sancho-Tello, María-José; Olagüe, José; Martínez-Dolz, Luis

    2017-01-01

    Active-fixation leads have been associated with higher incidence of cardiac perforation. Large series specifically evaluating this complication are lacking. We sought to evaluate the incidence and predictors of clinically relevant cardiac perforation in a consecutive series of patients implanted with active-fixation pacing and defibrillation leads. We conducted a retrospective observational study including all consecutive patients implanted with an active-fixation pacing/defibrillation lead at our institution from July 2008 to July 2015. The incidence of clinically relevant cardiac perforation and cardiac tamponade was evaluated. Univariate and multivariate analyses were used to identify predictors of cardiac perforation. Acute and long-term management of these patients was also investigated. A total of 3822 active-fixation pacing (n = 3035) and defibrillation (n = 787) leads were implanted in 2200 patients. Seventeen patients (0.8%) had clinically relevant cardiac perforation (13 acute and 4 subacute perforations), and 13 (0.5%) had cardiac tamponade resolved with pericardiocentesis. None of the patients with cardiac perforation required surgical treatment. In multivariate analysis, an age >80 years (OR 3.84, 95% CI 1.14-12.87, P = 0.029), female sex (OR 3.14, 95% CI 1.07-9.22, P = 0.037), and an apical position of the right ventricular lead (OR 3.37, 95% CI 1.17-9.67, P = 0.024) were independent predictors of cardiac perforation. Implantation of active-fixation leads is associated with a low incidence of clinically relevant cardiac perforation. Older and female patients have a higher risk of perforation as well as those patients receiving the ventricular lead in an apical position. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  15. Effects of shot peening pressure, media type and double shot peening on the microstructure, mechanical and tribological properties of low-alloy steel

    Science.gov (United States)

    Quang Trung, Pham; Win Khun, Nay; Butler, David Lee

    2016-12-01

    The effects of different shot peening conditions such as pressure (from 68.9-551.6 kPa), media type (media S230 and S110) and double shot peening on the microstructure, mechanical and tribological properties of shot peened AISI 4340 low-alloy steels, were systematically investigated. Their surface topography, hardness and roughness were analyzed by scanning electron microscopy, a Vickers micro-hardness tester and surface profilometer, respectively, while the cross-sectional sub-surface structures of the as-received and shot peened samples were characterized by means of optical microscopy and nanoindentation. The tribological properties were determined by using a ball-on-disc micro-tribological tester. It was shown that shot peening pressure and media type had a significant effect on the surface roughness, hardness, microstructure, wear resistance and friction of the shot peened AISI 4340 steel samples. It also indicated that the double shot peening process was a promising treatment, not only to reduce the surface roughness of the material after undergoing the first shot peening process with large media and high intensity, but to improve the tribological properties of the shot peened material.

  16. Photon shot noise dephasing in the strong-dispersive limit of circuit QED

    Science.gov (United States)

    Sears, A. P.; Petrenko, A.; Catelani, G.; Sun, L.; Paik, Hanhee; Kirchmair, G.; Frunzio, L.; Glazman, L. I.; Girvin, S. M.; Schoelkopf, R. J.

    2012-11-01

    We study the photon shot noise dephasing of a superconducting transmon qubit in the strong-dispersive limit, due to the coupling of the qubit to its readout cavity. As each random arrival or departure of a photon is expected to completely dephase the qubit, we can control the rate at which the qubit experiences dephasing events by varying in situ the cavity mode population and decay rate. This allows us to verify a pure dephasing mechanism that matches theoretical predictions, and in fact explains the increased dephasing seen in recent transmon experiments as a function of cryostat temperature. We observe large increases in coherence times as the cavity is decoupled from the environment, and after implementing filtering find that the intrinsic coherence of small Josephson junctions when corrected with a single Hahn echo is greater than several hundred microseconds. Similar filtering and thermalization may be important for other qubit designs in order to prevent photon shot noise from becoming the dominant source of dephasing.

  17. Ingestion of lead from ammunition and lead concentrations in white-tailed sea eagles (Haliaeetus albicilla) in Sweden.

    Science.gov (United States)

    Helander, B; Axelsson, J; Borg, H; Holm, K; Bignert, A

    2009-10-15

    In this study we show for the first time that lead poisoning from ammunition is a significant mortality factor for white-tailed sea eagle (WSE) (Haliaeetus albicilla) in Sweden. We analyzed 118 WSEs collected between 1981 and 2004 from which both liver and kidney samples could be taken. A total of 22% of all eagles examined had elevated (>6 microg/gd.w.) lead concentrations, indicating exposure to leaded ammunition, and 14% of the individuals had either liver or kidney lead concentrations diagnostic of lethal lead poisoning (>20 microg/gd.w.). Lead concentrations in liver and kidney were significantly correlated. In individuals with lead levels 20 microg/g, concentrations were significantly higher in liver. The lead isotope ratios indicate that the source of lead in individuals with lethal concentrations is different from that of individuals exhibiting background concentrations of lead (10 times higher than concentrations reported for Baltic fish from the same time period. In contrast to other biota there was no decrease in lead concentrations in WSE over the study period. The proportion of lead poisoned WSE remained unchanged over the study period, including two years after a partial ban of lead shot was enforced in 2002 for shallow wetlands. The use of lead in ammunition poses a threat to all raptors potentially feeding on shot game or offal. The removal of offal from shot game and alternatives to leaded ammunition needs to be implemented in order to prevent mortality from lead in raptors and scavengers.

  18. Multicentre comparison Of shock efficacy using single-vs. Dual-coil lead systems and Anodal vs. cathodaL polarITY defibrillation in patients undergoing transvenous cardioverter-defibrillator implantation. The MODALITY study.

    Science.gov (United States)

    Baccillieri, Maria Stella; Gasparini, Gianni; Benacchio, Luca; Zorzi, Alessandro; Marras, Elena; Zerbo, Francesca; Tomasi, Luca; Vaccari, Diego; Pastore, Gianni; Bonanno, Carlo; Molon, Giulio; Zanotto, Gabriele; Fusco, Antonio; Carasi, Massimo; Zorzi, Andrea; Calzolari, Vittorio; Ignatiuk, Barbara; Cannas, Sergio; Vaglio, Alessandro; Al Bunni, Muhamad; Pedrini, Antonella; Olivieri, Armando; Rampazzo, Roberta; Minicuci, Nadia; Corrado, Domenico; Verlato, Roberto

    2015-06-01

    An optimal active-can lead configuration during implantable cardioverter defibrillator (ICD) placement is important to obtain an adequate defibrillation safety margin. The purpose of this multicenter study was to evaluate the rate of the first shock success at defibrillation testing according to the type of lead implant (single vs. dual coil) and shock polarity (cathodal and anodal) in a large series of consecutive patients who received transvenous ICDs. This was a multicenter study enrolling 469 consecutive patients. Single- versus dual-coil leads and cathodal versus anodal polarity were evaluated at defibrillation testing. In all cases, the value of the energy for the first shock was set to 20 J less than the maximum energy deliverable from the device. A total of 469 patients underwent defibrillation testing: 158 (34 %) had dual-coil and 311 (66 %) had single-coil lead systems configuration, 254 (54 %) received anodal shock and 215 (46 %) received cathodal shock. In 35 (7.4 %) patients, the shock was unsuccessful. No significant differences in the outcome of defibrillation testing using single- versus dual-coil lead were observed but the multivariate analysis showed an increased risk of shock failure using cathodal shock polarity (OR 2.37, 95 % CI 1.12-5.03). Both single- and dual-coil transvenous ICD lead systems were associated with high rates of successful ICD implantation, and we found no significant differences in ventricular arrhythmias interruption between the two ICD lead systems configuration. Instead, anodal defibrillation was more likely to be successful than cathodal defibrillation.

  19. Quantum Sensing Beyond the Shot-Noise Limit with Plasmonic Sensors

    Science.gov (United States)

    Dowran, Mohammadjavad; Kumar, Ashok; Lawrie, Benjamin; Pooser, Raphael; Marino, Alberto

    2017-04-01

    The use of quantum resources offers the possibility of enhancing the sensitivity of a device beyond the shot noise limit and promises to revolutionize the field of metrology through the development of quantum enhanced sensors. In particular, plasmonic sensors, which are widely used in bio-chemical sensing applications, provide a unique opportunity to bring such an enhancement to real-life devices. Resonance plasmonic sensors respond to changes in refractive index through a shift of their characteristic transmission spectrum. We show that the use of quantum squeezed states to probe plasmonic sensors can enhance their sensitivity by lowering the noise floor and allowing the detection of smaller changes in refractive index. In our experiment, we use one of the beams of a two-mode squeezed state generated via four-wave-mixing in Rb atoms to probe the sensor. A squeezing level of 4 dB is obtained after transduction through the plasmonic sensor, which consists of a triangular nano-hole array in a thin silver film and exhibits a sensitivity of the order of 10-10 RIU /√{ Hz} . The use of quantum states leads to 40 % enhancement in the sensitivity of the plasmonic sensor with respect to the shot noise limit. Work supported by the W.M. Keck Foundation.

  20. Best depth of focus on 22-nm logic wafers with less shot count

    Science.gov (United States)

    Fujimura, Aki; Kim, David; Komagata, Tadashi; Nakagawa, Yasutoshi; Tolani, Vikram; Cecil, Tom

    2010-05-01

    The contact layer for the 22 nm logic node faces many technological hurdles. Even using techniques such as multiple-exposure patterning and 193 nm immersion, it will be difficult to achieve the depth of focus and CD uniformity required for 22 nm production. Such difficulties can be mitigated by recent advances in Inverse Lithography Technology (ILT). For example, circular main features combined with complex curvilinear assist features can provide superior CD uniformity with the required depth of focus, particularly for isolated contacts. However, such a solution can lead to long mask write times, because the curvilinear shapes necessitate a higher shot count induced by inefficient data fracturing, even without considering the circular main features. The current approach is to Manhattanize the curvilinear features resulting in a nearly equivalent image quality on the wafer; but a further reduction in mask write times could help lower costs. This paper describes a novel mask-writing method that uses a production e-beam mask writer to write main features as circles, with curvilinear assist features, while reducing shot count compared to traditional Manhattanized masks. As a result the new method makes manufacturing of ideal ILT-type masks feasible from a technical as well as from an economic standpoint. Resist-exposed SEM images are presented that validate the new method.

  1. The Distribution of the Interval between Events of a Cox Process with Shot Noise Intensity

    Directory of Open Access Journals (Sweden)

    Angelos Dassios

    2008-01-01

    Full Text Available Applying piecewise deterministic Markov processes theory, the probability generating function of a Cox process, incorporating with shot noise process as the claim intensity, is obtained. We also derive the Laplace transform of the distribution of the shot noise process at claim jump times, using stationary assumption of the shot noise process at any times. Based on this Laplace transform and from the probability generating function of a Cox process with shot noise intensity, we obtain the distribution of the interval of a Cox process with shot noise intensity for insurance claims and its moments, that is, mean and variance.

  2. On the Path to SunShot - Executive Summary

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2016-05-01

    The halfway mark of the SunShot Initiative’s 2020 target date is a good time to take stock: How much progress has been made? What have we learned? What barriers and opportunities must still be addressed to ensure that solar technologies achieve cost parity in 2020 and realize their full potential in the decades beyond? To answer these questions, the Solar Energy Technology Office launched the On the Path to SunShot series in early 2015 in collaboration with the National Renewable Energy Laboratory (NREL) and with contributions from Lawrence Berkeley National Laboratory (LBNL), Sandia National Laboratories (SNL), and Argonne National Laboratory (ANL). The reports focus on the areas of technology development, systems integration, and market enablers.

  3. Video Shot Boundary Recognition Based on Adaptive Locality Preserving Projections

    Directory of Open Access Journals (Sweden)

    Yongliang Xiao

    2013-01-01

    Full Text Available A novel video shot boundary recognition method is proposed, which includes two stages of video feature extraction and shot boundary recognition. Firstly, we use adaptive locality preserving projections (ALPP to extract video feature. Unlike locality preserving projections, we define the discriminating similarity with mode prior probabilities and adaptive neighborhood selection strategy which make ALPP more suitable to preserve the local structure and label information of the original data. Secondly, we use an optimized multiple kernel support vector machine to classify video frames into boundary and nonboundary frames, in which the weights of different types of kernels are optimized with an ant colony optimization method. Experimental results show the effectiveness of our method.

  4. Fraction in shot-put: A learning trajectory

    Science.gov (United States)

    Putri, R. I. I.; Zulkardi

    2017-08-01

    This research was aimed to produce a learning trajectory that can help students in the fractions learning by using shot-put context at the fourth grade. The method used in this research was research design which has three stages: preparing for the experiment, the design experiment, and the retrospective analysis. Data collection techniques used was interviews, video recordings and photographs, written tests, observation and field notes. This research involved six students who have the high capability, medium capability and low capability at the first cycle and 34 students at the second cycle. The research which was conducted produced learning trajectory that consisted of a series of learning in three mathematics activities. The results showed that by using shot-put context can help students in subtraction of fractions learning and can solve the problems dealing with subtraction of fractions in daily life by using PMRI.

  5. Genome-wide mRNA sequencing of a single canine cerebellar cortical degeneration case leads to the identification of a disease associated SPTBN2 mutation

    Directory of Open Access Journals (Sweden)

    Forman Oliver P

    2012-07-01

    Full Text Available Abstract Background Neonatal cerebellar cortical degeneration is a neurodegenerative disease described in several canine breeds including the Beagle. Affected Beagles are unable to ambulate normally from the onset of walking and the main pathological findings include Purkinje cell loss with swollen dendritic processes. Previous reports suggest an autosomal recessive mode of inheritance. The development of massively parallel sequencing techniques has presented the opportunity to investigate individual clinical cases using genome-wide sequencing approaches. We used genome-wide mRNA sequencing (mRNA-seq of cerebellum tissue from a single Beagle with neonatal cerebellar cortical degeneration as a method of candidate gene sequencing, with the aim of identifying the causal mutation. Results A four-week old Beagle dog presented with progressive signs of cerebellar ataxia and the owner elected euthanasia. Histopathology revealed findings consistent with cerebellar cortical degeneration. Genome-wide mRNA sequencing (mRNA-seq of RNA from cerebellum tissue was used as a method of candidate gene sequencing. After analysis of the canine orthologues of human spinocerebellar ataxia associated genes, we identified a homozygous 8 bp deletion in the β-III spectrin gene, SPTBN2, associated with spinocerebellar type 5 in humans. Genotype analysis of the sire, dam, ten clinically unaffected siblings, and an affected sibling from a previous litter, showed the mutation to fully segregate with the disorder. Previous studies have shown that β-III spectrin is critical for Purkinje cell development, and the absence of this protein can lead to cell damage through excitotoxicity, consistent with the observed Purkinje cell loss, degeneration of dendritic processes and associated neurological dysfunction in this Beagle. Conclusions An 8 bp deletion in the SPTBN2 gene encoding β-III spectrin is associated with neonatal cerebellar cortical degeneration in Beagle dogs

  6. Does maternal VDR FokI single nucleotide polymorphism have an effect on lead levels of placenta, maternal and cord bloods?

    Science.gov (United States)

    Kaya-Akyüzlü, Dilek; Kayaaltı, Zeliha; Söylemez, Esma; Koca, Deniz; Söylemezoğlu, Tülin

    2015-08-01

    Individual susceptibility due to genetic variations appears to be an important factor in lead toxicity. As lead, ubiquitous atmospheric pollutant, behaves very similarly to calcium, gene polymorphisms in proteins involved in calcium homeostasis can affect lead toxicokinetics. Vitamin D receptor (VDR), a DNA-binding transcription factor, activates genes that encode proteins involved in calcium metabolism. Thus, the objective of this study was to determine the effect of maternal VDR FokI polymorphism on lead levels of maternal blood, placental tissue and cord blood. The study population comprised 116 women and their respective placenta and umbilical cord. Venous blood samples were drawn from mothers to investigate both the lead levels and VDR FokI polymorphism. Cord blood samples and placentas were collected for lead levels. VDR FokI polymorphism was detected by standard polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP) method. Lead levels were analyzed by dual atomic absorption spectrometer system. Genotype frequencies of VDR FokI polymorphism were 49.2% FF, 44.8% Ff and 6.0% ff. The mean lead levels of maternal blood, placenta and cord blood were 36.76 ± 13.84 μg/L, 12.84 ± 14.47 μg/kg and 25.69 ± 11.12 μg/L, respectively. Maternal blood, placental and cord blood lead levels were found significantly to be higher in mothers with f allele for the VDR FokI polymorphism (p lead levels and that mothers with F allele associated with lower lead concentration may protect their respective fetus against the toxic effects of lead exposure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Project Rulison: post-shot plans and evaluations

    Energy Technology Data Exchange (ETDEWEB)

    1969-12-01

    Project Rulison post-shot plans and evaluations are discussed and include physical characteristics of the Rulison cavity; pressure and temperature expected in the cavity; amount, nature, and distribution of radioactivity in the cavity; reentry plan; radioactive species which may be encountered during reentry; public safety considerations arising from release of radioactivity; procedures to assure public safety; and the radiological safety plan. Maximum hypothetical accidents and ecological considerations are discussed in the appendices.

  8. Zero-Shot Learning by Generating Pseudo Feature Representations

    OpenAIRE

    Lu, Jiang; Li, Jin; Yan, Ziang; Zhang, Changshui

    2017-01-01

    Zero-shot learning (ZSL) is a challenging task aiming at recognizing novel classes without any training instances. In this paper we present a simple but high-performance ZSL approach by generating pseudo feature representations (GPFR). Given the dataset of seen classes and side information of unseen classes (e.g. attributes), we synthesize feature-level pseudo representations for novel concepts, which allows us access to the formulation of unseen class predictor. Firstly we design a Joint Att...

  9. Why Some Pool Shots are More Difficult Than Others

    Indian Academy of Sciences (India)

    IAS Admin

    ical principles our treatment ignores the ball's spin, friction, and other well-known effects in the game of pool. Anyone who has ever played a game of pool, a form of billiards, is intuitively familiar with the following sce- nario: When a cue ball, an object ball, and a pocket lie more or less in a straight line (Figure 1a), the shot is.

  10. SnapShot: Hormones of the gastrointestinal tract.

    Science.gov (United States)

    Coate, Katie C; Kliewer, Steven A; Mangelsdorf, David J

    2014-12-04

    Specialized endocrine cells secrete a variety of peptide hormones all along the gastrointestinal (GI) tract, making it one of the largest endocrine organs in the body. Nutrients and developmental and neural cues trigger the secretion of gastrointestinal (GI) hormones from specialized endocrine cells along the GI tract. These hormones act in target tissues to facilitate digestion and regulate energy homeostasis. This SnapShot summarizes the production and functions of GI hormones. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Observability of radiation-pressure shot noise in optomechanical systems

    Science.gov (United States)

    Børkje, K.; Nunnenkamp, A.; Zwickl, B. M.; Yang, C.; Harris, J. G. E.; Girvin, S. M.

    2010-07-01

    We present a theoretical study of an experiment designed to detect radiation-pressure shot noise in an optomechanical system. Our model consists of a coherently driven optical cavity mode that is coupled to a mechanical oscillator. We examine the cross-correlation between two quadratures of the output field from the cavity. We determine under which circumstances radiation-pressure shot noise can be detected by a measurement of this cross-correlation. This is done in the general case of nonzero detuning between the frequency of the drive and the cavity resonance frequency. We study the qualitative features of the different contributions to the cross-correlator and provide quantitative figures of merit for the relative importance of the radiation-pressure shot noise contribution to other contributions. We also propose a modified setup of this experiment relevant to the “membrane-in-the-middle” geometry, which potentially can avoid the problems of static bistability and classical noise in the drive.

  12. First-time viewers' comprehension of films: bridging shot transitions.

    Science.gov (United States)

    Ildirar, Sermin; Schwan, Stephan

    2015-02-01

    Which perceptual and cognitive prerequisites must be met in order to be able to comprehend a film is still unresolved and a controversial issue. In order to gain some insights into this issue, our field experiment investigates how first-time adult viewers extract and integrate meaningful information across film cuts. Three major types of commonalities between adjacent shots were differentiated, which may help first-time viewers with bridging the shots: pictorial, causal, and conceptual. Twenty first-time, 20 low-experienced and 20 high-experienced viewers from Turkey were shown a set of short film clips containing these three kinds of commonalities. Film clips conformed also to the principles of continuity editing. Analyses of viewers' spontaneous interpretations show that first-time viewers indeed are able to notice basic pictorial (object identity), causal (chains of activity), as well as conceptual (links between gaze direction and object attention) commonalities between shots due to their close relationship with everyday perception and cognition. However, first-time viewers' comprehension of the commonalities is to a large degree fragile, indicating the lack of a basic notion of what constitutes a film. © 2014 The British Psychological Society.

  13. Transfer of mechanical energy during the shot put

    Directory of Open Access Journals (Sweden)

    Błażkiewicz Michalina

    2016-09-01

    Full Text Available The aim of this study was to analyse transfer of mechanical energy between body segments during the glide shot put. A group of eight elite throwers from the Polish National Team was analysed in the study. Motion analysis of each throw was recorded using an optoelectronic Vicon system composed of nine infrared camcorders and Kistler force plates. The power and energy were computed for the phase of final acceleration of the glide shot put. The data were normalized with respect to time using the algorithm of the fifth order spline and their values were interpolated with respect to the percentage of total time, assuming that the time of the final weight acceleration movement was different for each putter. Statistically significant transfer was found in the study group between the following segments: Right Knee – Right Hip (p = 0.0035, Left Hip - Torso (p = 0.0201, Torso – Right Shoulder (p = 0.0122 and Right Elbow – Right Wrist (p = 0.0001. Furthermore, the results of cluster analysis showed that the kinetic chain used during the final shot acceleration movement had two different models. Differences between the groups were revealed mainly in the energy generated by the hips and trunk.

  14. A Shot Parameter Specification Subsystem for automated control of PBFA [Particle Beam Fusion Accelerator] II accelerator shots

    International Nuclear Information System (INIS)

    Spiller, J.L.

    1987-01-01

    The Shot Parameter Specification Subsystem (SPSS) is an integral part of the automatic control system developed for the Particle Beam Fusion Accelerator II (PBFA II) by the Control Monitor (C/M) Software Development Team. This system has been designed to fully utilize the accelerator by tailoring shot parameters to the needs of the experimenters. The SPSS is the key to this flexibility. Automatic systems will be required on many pulsed power machines for the fastest turnaround, the highest reliability, and most cost effective operation. These systems will require the flexibility and the ease of use that is part of the SPSS. The PBFA II control system has proved to be an effective modular system, flexible enough to meet the demands of both the fast track construction of PBFA II and the control needs of Hermes III at the Simulation Technology Laboratory. This system is expected to meet the demands of most future machine changes

  15. Multiphoton double ionization of Ar in intense extreme ultraviolet laser fields studied by shot-by-shot photoelectron spectroscopy.

    Science.gov (United States)

    Hikosaka, Y; Fushitani, M; Matsuda, A; Tseng, C-M; Hishikawa, A; Shigemasa, E; Nagasono, M; Tono, K; Togashi, T; Ohashi, H; Kimura, H; Senba, Y; Yabashi, M; Ishikawa, T

    2010-09-24

    Photoelectron spectroscopy has been performed to study the multiphoton double ionization of Ar in an intense extreme ultraviolet laser field (hν ∼ 21  eV, ∼ 5  TW/cm²), by using a free electron laser (FEL). Three distinct peaks identified in the observed photoelectron spectra clearly show that the double ionization proceeds sequentially via the formation of Ar(+): Ar+hν→Ar (+) + e⁻ and Ar²(+) + 2hν→Ar(+) + e⁻. Shot-by-shot recording of the photoelectron spectra allows simultaneous monitoring of FEL spectrum and the multiphoton process for each FEL pulse, revealing that the two-photon ionization from Ar(+) is significantly enhanced by intermediate resonances in Ar(+).

  16. Effects of Rayleigh damping, friction and rate-dependency on 3D residual stress simulation of angled shot peening

    International Nuclear Information System (INIS)

    Kim, Taehyung; Lee, Hyungyil; Hyun, Hong Chul; Jung, Sunghwan

    2013-01-01

    Highlights: ► We propose a 3D FE model to study peening residual stress involving angled shots. ► The FE model set with plastic shot are found to best match the X-ray diffraction data. ► The model provides 3D multi-shot impact FE solution with various incidence angles. - Abstract: In this study, we propose a 3D finite element (FE) model to study shot peening involving angled shots. Using the FE model for angled shot peening, we examine relationships with the residual stress introduced by shot peening of the factors such as the Rayleigh damping in the material, dynamic friction, and the rate dependency of the material and systematically integrate them with the FE model. The FE model is set with rigid shot, elastic shot, and plastic shot respectively. Plastic deformation of the shot is also explored with the FE model. The FE model is applied to study angled multi-shots. The FE results are verified with experimental data using X-ray diffraction (XRD). The FE model set with plastic shot are found to best match the XRD results validating accuracy of the 3D FE model properly integrated with the factors and plastically deformable shot ball. The proposed model will serve to simulate actual shot peening cases, which generally involve multi-shots with various incidence angles

  17. A bootstrapped, low-noise, and high-gain photodetector for shot noise measurement

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Haijun; Yang, Wenhai; Li, Zhixiu; Li, Xuefeng; Zheng, Yaohui, E-mail: yhzheng@sxu.edu.cn [State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Opto-Electronics, Shanxi University, Taiyuan 030006 (China)

    2014-01-15

    We presented a low-noise, high-gain photodetector based on the bootstrap structure and the L-C (inductance and capacitance) combination. Electronic characteristics of the photodetector, including electronic noise, gain and frequency response, and dynamic range, were verified through a single-frequency Nd:YVO{sub 4} laser at 1064 nm with coherent output. The measured shot noise of 50 μW laser was 13 dB above the electronic noise at the analysis frequency of 2 MHz, and 10 dB at 3 MHz. And a maximum clearance of 28 dB at 2 MHz was achieved when 1.52 mW laser was illuminated. In addition, the photodetector showed excellent linearities for both DC and AC amplifications in the laser power range between 12.5 μW and 1.52 mW.

  18. Near shot-noise limited time-resolved circular dichroism pump-probe spectrometer

    Science.gov (United States)

    Stadnytskyi, Valentyn; Orf, Gregory S.; Blankenship, Robert E.; Savikhin, Sergei

    2018-03-01

    We describe an optical near shot-noise limited time-resolved circular dichroism (TRCD) pump-probe spectrometer capable of reliably measuring circular dichroism signals in the order of μdeg with nanosecond time resolution. Such sensitivity is achieved through a modification of existing TRCD designs and introduction of a new data processing protocol that eliminates approximations that have caused substantial nonlinearities in past measurements and allows the measurement of absorption and circular dichroism transients simultaneously with a single pump pulse. The exceptional signal-to-noise ratio of the described setup makes the TRCD technique applicable to a large range of non-biological and biological systems. The spectrometer was used to record, for the first time, weak TRCD kinetics associated with the triplet state energy transfer in the photosynthetic Fenna-Matthews-Olson antenna pigment-protein complex.

  19. SU-F-P-36: Automation of Linear Accelerator Star Shot Measurement with Advanced XML Scripting and Electronic Portal Imaging Device

    International Nuclear Information System (INIS)

    Nguyen, N; Knutson, N; Schmidt, M; Price, M

    2016-01-01

    Purpose: To verify a method used to automatically acquire jaw, MLC, collimator and couch star shots for a Varian TrueBeam linear accelerator utilizing Developer Mode and an Electronic Portal Imaging Device (EPID). Methods: An XML script was written to automate motion of the jaws, MLC, collimator and couch in TrueBeam Developer Mode (TBDM) to acquire star shot measurements. The XML script also dictates MV imaging parameters to facilitate automatic acquisition and recording of integrated EPID images. Since couch star shot measurements cannot be acquired using a combination of EPID and jaw/MLC collimation alone due to a fixed imager geometry, a method utilizing a 5mm wide steel ruler placed on the table and centered within a 15×15cm2 open field to produce a surrogate of the narrow field aperture was investigated. Four individual star shot measurements (X jaw, Y jaw, MLC and couch) were obtained using our proposed as well as traditional film-based method. Integrated EPID images and scanned measurement films were analyzed and compared. Results: Star shot (X jaw, Y jaw, MLC and couch) measurements were obtained in a single 5 minute delivery using the TBDM XML script method compared to 60 minutes for equivalent traditional film measurements. Analysis of the images and films demonstrated comparable isocentricity results, agreeing within 0.3mm of each other. Conclusion: The presented automatic approach of acquiring star shot measurements using TBDM and EPID has proven to be more efficient than the traditional film approach with equivalent results.

  20. SU-F-P-36: Automation of Linear Accelerator Star Shot Measurement with Advanced XML Scripting and Electronic Portal Imaging Device

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, N; Knutson, N; Schmidt, M; Price, M [Rhode Island Hospital / Warren Alpert Medical, Providence, RI (United States)

    2016-06-15

    Purpose: To verify a method used to automatically acquire jaw, MLC, collimator and couch star shots for a Varian TrueBeam linear accelerator utilizing Developer Mode and an Electronic Portal Imaging Device (EPID). Methods: An XML script was written to automate motion of the jaws, MLC, collimator and couch in TrueBeam Developer Mode (TBDM) to acquire star shot measurements. The XML script also dictates MV imaging parameters to facilitate automatic acquisition and recording of integrated EPID images. Since couch star shot measurements cannot be acquired using a combination of EPID and jaw/MLC collimation alone due to a fixed imager geometry, a method utilizing a 5mm wide steel ruler placed on the table and centered within a 15×15cm2 open field to produce a surrogate of the narrow field aperture was investigated. Four individual star shot measurements (X jaw, Y jaw, MLC and couch) were obtained using our proposed as well as traditional film-based method. Integrated EPID images and scanned measurement films were analyzed and compared. Results: Star shot (X jaw, Y jaw, MLC and couch) measurements were obtained in a single 5 minute delivery using the TBDM XML script method compared to 60 minutes for equivalent traditional film measurements. Analysis of the images and films demonstrated comparable isocentricity results, agreeing within 0.3mm of each other. Conclusion: The presented automatic approach of acquiring star shot measurements using TBDM and EPID has proven to be more efficient than the traditional film approach with equivalent results.

  1. An Eye-tracking Study of Feature-based Choice in One-shot Games

    DEFF Research Database (Denmark)

    Devetag, Giovanna; Di Guida, Sibilla; Polonio, Luca

    2016-01-01

    with the highest average payoff" or "choose the strategy leading to an attractive and symmetric outcome" without (optimally) incorporating knowledge on the opponent’s behavior. Lookup patterns resulted being feature and game invariant, heterogeneous across subjects, but stable within subjects. Using a cluster...... for a subset of game outcomes. We analyze subjects’ eye movements while playing a series of two-person, 3x3 one-shot games in normal form. Games within each class differ by a set of descriptive features (i.e., features that can be changed without altering the game equilibrium properties). Data show...... that subjects on average perform partial or non-strategic analysis of the payoff matrix, often ignoring the opponent´s payoffs and rarely performing the necessary steps to detect dominance. Our analysis of eye-movements supports the hypothesis that subjects use simple decision rules such as "choose the strategy...

  2. Lead Poisoning

    Science.gov (United States)

    Lead is a metal that occurs naturally in the earth's crust. Lead can be found in all parts of our ... from human activities such as mining and manufacturing. Lead used to be in paint; older houses may ...

  3. Get the lead out: Wildlife advocates file suit to replace toxic ammo ...

    African Journals Online (AJOL)

    2007-03-02

    Mar 2, 2007 ... Get the lead out: Wildlife advocates file suit to replace toxic ammo with safer alternatives. Simple, practical ... who eats game, which often contains shot or small metal fragments. Lead is an extremely toxic ... eating meat from animals taken with lead ammunition often have unhealthy lead levels in their own ...

  4. Site-specific lead exposure from lead pellet ingestion in sentinel mallards

    Science.gov (United States)

    Rocke, T.E.; Brand, C.J.; Mensik, John G.

    1997-01-01

    We monitored lead poisoning from the ingestion of spent lead pellets in sentinel mallards (Anas platyhrynchos) at the Sacramento National Wildlife Refuge (SNWR), Willows, California for 4 years (1986-89) after the conversion to steel shot for waterfowl hunting on refuges in 1986. Sentinel mallards were held in 1.6-ha enclosures in 1 hunted (P8) and 2 non-hunted (T19 and TF) wetlands. We compared site-specific rates of lead exposure, as determined by periodic measurement of blood lead concentrations, and lead poisoning mortality between wetlands with different lead pellet densities, between seasons, and between male and female sentinels. In 1986, the estimated 2-week rate of lead exposure was significantly higher (P 2,000,000 pellets/ha), than in those with lower densities of lead pellets, T19 (18.1%; 173,200 pellets/ha) and TF (0.9%; 15,750 pellets/ha). The probability of mortality from lead poisoning was also significantly higher (P exposure and the probability of lead poisoning mortality in P8 were significantly higher (P exposure or lead poisoning mortality between male and female sentinel mallards. The results of this study demonstrate that in some locations, lead exposure and lead poisoning in waterfowl will continue to occur despite the conversion to steel shot for waterfowl hunting.

  5. Methodology for calculating guideline concentrations for safety shot sites

    International Nuclear Information System (INIS)

    1997-06-01

    Residual plutonium (Pu), with trace quantities of depleted uranium (DU) or weapons grade uranium (WU), exists in surficial soils at the Nevada Test Site (NTS), Nellis Air Force Range (NAFR), and the Tonopah Test Range (TTR) as the result of the above-ground testing of nuclear weapons and special experiments involving the detonation of plutonium-bearing devices. The special experiments (referred to as safety shots) involving plutonium-bearing devices were conducted to study the behavior of Pu as it was being explosively compressed; ensure that the accidental detonation of the chemical explosive in a production weapon would not result in criticality; evaluate the ability of personnel to manage large-scale Pu dispersal accidents; and develop criteria for transportation and storage of nuclear weapons. These sites do not pose a health threat to either workers or the general public because they are under active institutional control. The DOE is committed to remediating the safety shot sites so that radiation exposure to the public, both now and in the future, will be maintained within the established limits and be as low as reasonably achievable. Remediation requires calculation of a guideline concentration for the Pu, U, and their decay products that are present in the surface soil. This document presents the methodology for calculating guideline concentrations of weapons grade plutonium, weapons grade uranium, and depleted uranium in surface soils at the safety shot sites. Emphasis is placed on obtaining site-specific data for use in calculating dose to potential residents from the residual soil contamination

  6. Methodology for calculating guideline concentrations for safety shot sites

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-06-01

    Residual plutonium (Pu), with trace quantities of depleted uranium (DU) or weapons grade uranium (WU), exists in surficial soils at the Nevada Test Site (NTS), Nellis Air Force Range (NAFR), and the Tonopah Test Range (TTR) as the result of the above-ground testing of nuclear weapons and special experiments involving the detonation of plutonium-bearing devices. The special experiments (referred to as safety shots) involving plutonium-bearing devices were conducted to study the behavior of Pu as it was being explosively compressed; ensure that the accidental detonation of the chemical explosive in a production weapon would not result in criticality; evaluate the ability of personnel to manage large-scale Pu dispersal accidents; and develop criteria for transportation and storage of nuclear weapons. These sites do not pose a health threat to either workers or the general public because they are under active institutional control. The DOE is committed to remediating the safety shot sites so that radiation exposure to the public, both now and in the future, will be maintained within the established limits and be as low as reasonably achievable. Remediation requires calculation of a guideline concentration for the Pu, U, and their decay products that are present in the surface soil. This document presents the methodology for calculating guideline concentrations of weapons grade plutonium, weapons grade uranium, and depleted uranium in surface soils at the safety shot sites. Emphasis is placed on obtaining site-specific data for use in calculating dose to potential residents from the residual soil contamination.

  7. Lead Poisoning in Wild Birds

    Science.gov (United States)

    Lahner, Lesanna L.; Franson, J. Christian

    2009-01-01

    Lead in its various forms has been used for thousands of years, originally in cooking utensils and glazes and more recently in many industrial and commercial applications. However, lead is a potent, potentially deadly toxin that damages many organs in the body and can affect all animals, including humans. By the mid 1990s, lead had been removed from many products in the United States, such as paint and fuel, but it is still commonly used in ammunition for hunting upland game birds, small mammals, and large game animals, as well as in fishing tackle. Wild birds, such as mourning doves, bald eagles, California condors, and loons, can die from the ingestion of one lead shot, bullet fragment, or sinker. According to a recent study on loon mortality, nearly half of adult loons found sick or dead during the breeding season in New England were diagnosed with confirmed or suspected lead poisoning from ingestion of lead fishing weights. Recent regulations in some states have restricted the use of lead ammunition on certain upland game hunting areas, as well as lead fishing tackle in areas frequented by common loons and trumpeter swans. A variety of alternatives to lead are available for use in hunting, shooting sports, and fishing activities.

  8. Luminescence and photo-thermally stimulated defect-creation processes in Bi.sup.3+./sup.-doped single crystals of lead tungstate

    Czech Academy of Sciences Publication Activity Database

    Buryi, Maksym; Boháček, Pavel; Chernenko, K.; Krasnikov, A.; Laguta, Valentyn; Mihóková, Eva; Nikl, Martin; Zazubovich, S.

    2016-01-01

    Roč. 123, č. 5 (2016), 895-910 ISSN 0370-1972 R&D Projects: GA ČR GAP204/12/0805 Institutional support: RVO:68378271 Keywords : defects * EPR * excitons * PbWO 4 :Bi single crystals * photoluminescence * thermoluminescence Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.674, year: 2016

  9. One-shot service searches: Preprint repositories at a mouseclick

    International Nuclear Information System (INIS)

    Canessa, E.; Pastore, G.

    1996-09-01

    In this article we introduce the ICTP-International Centre for Theoretical Physics's prototype for a ''One-Shot World-Wide Preprints Search'' on the Web. This is a new centralized interface for a global search throughout the most popular scientific preprint repositories. Herein, we briefly discuss our experience with the implementation of this service and propose it as a possible alternative solution to the problem of getting access to the information without being either overloaded with lots of new documents or not being informed at all. (author). 13 refs, 3 figs

  10. INFLUENCE OF SHOT PEENING ON AISI 316Ti FATIGUE PROPERTIES

    Directory of Open Access Journals (Sweden)

    Mario Guagliano

    2012-05-01

    Full Text Available This paper deals with examination of fatigue properties of AISI 316Ti stainless steel before and after shot peening including analysis of residual stress relaxation during rotating bending fatigue tests (f = 50 Hz, T = 20 ± 3 °C, R = - 1 with use of X - ray diffractometer. Obtained experimental results show increase of fatigue properties in the high – cycle region including fatigue limit and show the behavior of residual stress, decrease, at given cyclic loading amplitude in the region from N = 103 cycles to N = 107 cycles of loading.

  11. The example of the UK SHOT haemovigilance system

    Directory of Open Access Journals (Sweden)

    Perla Eleftheriou

    2014-12-01

    Full Text Available SHOT (Serious Hazards of Transfusion scheme is the UK’s National confidential haemovigilance system, and was set up in 1996. It is an independent, confidential, professionally led haemovigilance scheme. Initially the reporting was voluntary but now required by several professional bodies. SHOT publishes annual reports with recommendations and circulates to all relevant organizations including the 4 UK Blood services, Departments of Health in England, Wales, Scotland and Northern Ireland, all relevant professional bodies and reporting hospitals. Over the 17 years of reporting, the evidence gathered has prompted changes in transfusion practice from the selection and management of donors to changes in hospital practice, better education and training. Acute transfusion reactions and transfusion-associated circulatory overload carry the highest risk for morbidity and death. Greatest risk to patients remain errors in the process at the point of blood sampling, in the laboratory and at bedside administration. SHOT’s objectives are to use findings to improve standards of hospital transfusion practice, to educate users on transfusion hazards and prevention, to aid production of clinical guidelines in blood transfusion and to inform national policy on transfusion safety. MHRA is the UK competent authority to which serious adverse reactions and events have to be reported annually. Overall the most common adverse incidents are caused by errors, resulting in the transfusion of an incorrect component or one that does not meet the specific requirements of the patient (e.g. not irradiated or not appropriately antigen matched. TACO (transfusion associated circulatory overload accounts for most deaths and major morbidity reported to SHOT but is overall underreported. Transfusions are not always given appropriately. This may be due to wrong haemoglobin results, failure to assess patients appropriately, or avoidable use of emergency O RhD negative units because

  12. A frequency-domain derivation of shot-noise

    Science.gov (United States)

    Rice, Frank

    2016-01-01

    A formula for shot-noise is derived in the frequency-domain. The derivation is complete and reasonably rigorous while being appropriate for undergraduate students; it models a sequence of random pulses using Fourier sine and cosine series, and requires some basic statistical concepts. The text here may serve as a pedagogic introduction to the spectral analysis of random processes and may prove useful to introduce students to the logic behind stochastic problems. The concepts of noise power spectral density and equivalent noise bandwidth are introduced.

  13. Micro-MID Manufacturing By Two-Shot Injection Moulding

    DEFF Research Database (Denmark)

    Islam, Mohammad Aminul; Hansen, Hans Nørgaard; Tang, Peter Torben

    2008-01-01

    a specific MID process chain is used for micro products, many technical challenges are encountered which would not be problems for macro scale products. This paper investigates on a specific MID process chain (two shot moulding) and discusses the technical difficulties associated with the production process...... when the production shifts from macro to micro scale products. The investigation shows that some of the materials which are suitable for macro MIDs are not suitable for micro MIDs. Polymer-polymer bond strength, interface between two polymers and interface metallization of polymers are critical...

  14. Single Sustained Inflation followed by Ventilation Leads to Rapid Cardiorespiratory Recovery but Causes Cerebral Vascular Leakage in Asphyxiated Near-Term Lambs.

    Directory of Open Access Journals (Sweden)

    Kristina S Sobotka

    Full Text Available A sustained inflation (SI rapidly restores cardiac function in asphyxic, bradycardic newborns but its effects on cerebral haemodynamics and brain injury are unknown. We determined the effect of different SI strategies on carotid blood flow (CaBF and cerebral vascular integrity in asphyxiated near-term lambs.Lambs were instrumented and delivered at 139 ± 2 d gestation and asphyxia was induced by delaying ventilation onset. Lambs were randomised to receive 5 consecutive 3 s SI (multiple SI; n = 6, a single 30 s SI (single SI; n = 6 or conventional ventilation (no SI; n = 6. Ventilation continued for 30 min in all lambs while CaBF and respiratory function parameters were recorded. Brains were assessed for gross histopathology and vascular leakage.CaBF increased more rapidly and to a greater extent during a single SI (p = 0.01, which then decreased below both other groups by 10 min, due to a higher cerebral oxygen delivery (p = 0.01. Blood brain barrier disruption was increased in single SI lambs as indicated by increased numbers of blood vessel profiles with plasma protein extravasation (p = 0.001 in the cerebral cortex. There were no differences in CaBF or cerebral oxygen delivery between the multiple SI and no SI lambs.Ventilation with an initial single 30 s SI improves circulatory recovery, but is associated with greater disruption of blood brain barrier function, which may exacerbate brain injury suffered by asphyxiated newborns. This injury may occur as a direct result of the initial SI or to the higher tidal volumes delivered during subsequent ventilation.

  15. Gradient echo single scan inversion recovery: application to proton and fluorine relaxation studies.

    Science.gov (United States)

    Pavuluri, KowsalyaDevi; Ramanathan, K V

    2016-02-01

    Single scan longitudinal relaxation measurement experiments enable rapid estimation of the spin-lattice relaxation time (T1 ) as the time series of spin relaxation is encoded spatially in the sample at different slices resulting in an order of magnitude saving in time. We consider here a single scan inversion recovery pulse sequence that incorporates a gradient echo sequence. The proposed pulse sequence provides spectra with significantly enhanced signal to noise ratio leading to an accurate estimation of T1 values. The method is applicable for measuring a range of T1 values, thus indicating the possibility of routine use of the method for several systems. A comparative study of different single scan methods currently available is presented, and the advantage of the proposed sequence is highlighted. The possibility of the use of the method for the study of cross-correlation effects for the case of fluorine in a single shot is also demonstrated. Copyright © 2015 John Wiley & Sons, Ltd.

  16. Effect of shot peening on crack growth resistance in corrosion environment

    International Nuclear Information System (INIS)

    Jin, Young Beom; Park, Keyung Dong

    2005-01-01

    Antifatigue failure technology take an important the part of current industries. Currently, the shot peening is used for removing the defect from the surface of steel and improving the fatigue strength on surface. Therefore in this paper the effect of compressive residual stress by shot peening on fatigue crack growth characteristics in stress ratio(R=0.05)was investigated with considering fracture mechanics. There is difference between shot peening specimen and unpeening specimen. Fatigue crack growth rate of shot peening specimen was lower than that of unpeening. Fatigue life shows more improvement in the shot peening material than in the unpeening material. And compressive residual stress of surface on the shot peening process operate resistance force of fatigue propagation

  17. Lead Toxicity

    Science.gov (United States)

    ... time may lead to reduced IQ, slow learning, Attention Deficit Hyperactivity Disorder (ADHD), or behavioral issues. • Lead also affects other parts ... 800-424-5323) • U.S. Environmental Protection Agency Lead Awareness Program http: / / www. epa. gov/ lead • EPA publication “ ...

  18. Temperature dependence of shot noise in double barrier magnetic tunnel junctions

    Science.gov (United States)

    Niu, Jiasen; Liu, Liang; Feng, J. F.; Han, X. F.; Coey, J. M. D.; Zhang, X.-G.; Wei, Jian

    2018-03-01

    Shot noise reveals spin dependent transport properties in a magnetic tunnel junction. We report measurement of shot noise in CoFeB/MgO/CoFeB/MgO/CoFeB double barrier magnetic tunnel junctions, which shows a strong temperature dependence. The Fano factor used to characterize shot noise increases with decreasing temperature. A sequential tunneling model can be used to account for these results, in which a larger Fano factor results from larger spin relaxation length at lower temperatures.

  19. Characterization of cryogenic direct-drive ICF targets during layering studies and just prior to shot time

    Energy Technology Data Exchange (ETDEWEB)

    Edgell, D.H.; Seka, W.; Craxton, R.S.; Elasky, L.M.; Harding, D.R.; Keck, R.L.; Lund, L.D.; Wittman, M.D. [Rochester Univ., Lab. for Laser Energetics, NY (United States)

    2006-06-15

    The characterization of OMEGA cryogenic targets is based on shadow-graphs obtained from multiple angular views taken with the target in the layering sphere. The D{sub 2} ice has been observed to re-layer during slow rotations, leading to procedural changes that avoid re-layering thus ensuring high-quality, spherical-harmonic, 3-dimensional ice layer reconstructions. Shadow-grams taken inside the target chamber within 20 ms of shot time have verified that the ice layers remain preserved during the transport. (authors)

  20. Effects of shot peening on the friction and wear of a metallic material

    International Nuclear Information System (INIS)

    Kim, Joo Young; Kim, Tae Hyung; Cheong, Seong Kyun

    2002-01-01

    This paper investigates the characteristics of friction and wear of shot peened AI 7075. Three types of specimens were used to get the experimental results. One type of specimen was made by machining and polishing. Another type of specimen was made by machining, shot peening. The other type of specimen was made by machining, shot peening, and polishing. TE77(PLINT) friction and wear tester was used to obtain the experimental data under 100N and 3Hz. The experimental results show that the shot peening process enhances the hardness near the surface of specimens and improves the wear resistance

  1. Development of a shot-blasting robot for removal of the wall concrete surface

    International Nuclear Information System (INIS)

    Tokioka, Seigo; Inagaki, Hiroichi; Sakai, Sachio; Kasahara, Ichirou; Ishigami, Shinya

    1991-01-01

    This paper reports research and development of a shot-blasting robot, for which the following targets are set up and their performances confirmed through basic experiments: (1) Uniform removal of concrete surface by an impeller type shot-blasting system. (2) Recycling of projecting material (steel shot). (3) Separation of removal material. And on the basis of these, its application to decontamination of nuclear power facilities is projected. The following three problems were focused on and the results of study are reported as follows: Step 1 : As part of a mechanical basic test, a manual type shot-blasting unit was mounted on a test device which may move freely on the concrete, and its data concerning finishing performance was obtained. Step 2 : On the basis of the results of the mechanization basic test, remote controlling of the shot blasting unit and its mounting on the suction type self-climbing carriage were studied first, secondly data of shot-blasting, operation and control method was gathered to develop a shot-blasting robot. Step 3 : A shot-blasting test was conducted for confirming climbing and shot-blasting performances. (author)

  2. Study on the use of types of shots in Valencian Handball on professional players

    Directory of Open Access Journals (Sweden)

    José Antonio Martínez Carbonell

    2013-01-01

    Full Text Available Due to the shortage of studies of analysis in Valencian ball, we have centred this study on this sport. The aim of study has been to analyze and to quantify the types of shots , and to compare the same ones between the positions of game of 1st game line (resto and 2nd game line (medio. Analysis of 6 games of the 19th Professional League of Stand and rope 2009-2010 was carried out so i, and specifically of 12 players, using Sports Code analysis software. The results indicate significant differences (p<0.05 between the shots carried out by first game line player and second game line in the rebound and rebound-shot all of them of right and left hand,and stand shot right hand; being almost realitzados only by players from the first game line position. At the same time we find data which demonstrate us by another band used mainly by second game line players beatings, these have been volley shot, volley shot after bounce, volley shot under the line of the shoulders, palm shot and horizontal shot all of them of right hand. As conclusion of the study, we have obtained that depending on the position of game the players use a few types of I throb or others. Therefore, we affirm, that the analysis of the high performance in stand and rope from the advances of the technologies, a valuable information contributes us to establish specific bosses of training.

  3. A study on corrosive behavior of spring steel by shot-peening process

    International Nuclear Information System (INIS)

    An, Jae Pil; Park, Keyung Dong

    2004-01-01

    In this study, the influence of shot peening on the corrosion was investigated on spring steel immersed in 3.5% NaCl. The immersion test was performed on the two kinds of specimens. Corrosion potential, polarization curve, residual stress and etc. were investigated from experimental results. From test results, the effect of shot peening on the corrosion was evaluated. In case of corrosion potential, shot peened specimen shows more activated negative direction as compared with parent metal. Surface of specimen, which is treated with the shot peened, is placed as more activated state against inner base metal. It can cause the anti-corrosion effect on the base metal

  4. Muscular power, neuromuscular activation, and performance in shot put athletes at preseason and at competition period.

    Science.gov (United States)

    Kyriazis, Thomas A; Terzis, Gerasimos; Boudolos, Konstantinos; Georgiadis, Georgios

    2009-09-01

    The aim of this study was to investigate changes in shot put performance, muscular power, and neuromuscular activation of the lower extremities, between the preseason and the competition period, in skilled shot put athletes using the rotational technique. Shot put performance was assessed at the start of the pre-season period as well as after 12 weeks, at the competition period, in nine shot putters. Electromyographic (EMG) activity of the right vastus lateralis muscle was recorded during all shot put trials. Maximum squat strength (1RM) and mechanical parameters during the countermovement jump (CMJ) on a force platform were also determined at pre-season and at competition period. Shot put performance increased 4.7% (p Shot put performance was significantly related with muscular power and takeoff velocity during the CMJ, at competition period (r = 0.66, p shot put performance. These results suggest that muscular power of the lower extremities is a better predictor of rotational shot put performance than absolute muscular strength in skilled athletes, at least during the competition period.

  5. The Numerical FEM Model of the Kinematics of the Vibratory Shot Peening Process

    Directory of Open Access Journals (Sweden)

    Stanisław Bławucki

    2017-12-01

    Full Text Available The paper presents the results of numerical calculations, with the finite element method in the ABAQUS program environment, of the vibratory shot peening process with loose peening elements. The behaviour of shot peening elements was analysed in the kinematic aspect. The impact of the initial deployment of vibratory shot peening elements on their behaviour during processing was investigated, including the displacement, velocity, acceleration and the number of collisions. The way of determining the effectiveness of the processing with the vibratory shot peening was illustrated.

  6. A Genetic Algorithm and Fuzzy Logic Approach for Video Shot Boundary Detection.

    Science.gov (United States)

    Thounaojam, Dalton Meitei; Khelchandra, Thongam; Manglem Singh, Kh; Roy, Sudipta

    2016-01-01

    This paper proposed a shot boundary detection approach using Genetic Algorithm and Fuzzy Logic. In this, the membership functions of the fuzzy system are calculated using Genetic Algorithm by taking preobserved actual values for shot boundaries. The classification of the types of shot transitions is done by the fuzzy system. Experimental results show that the accuracy of the shot boundary detection increases with the increase in iterations or generations of the GA optimization process. The proposed system is compared to latest techniques and yields better result in terms of F1score parameter.

  7. Sensitivity improvement of one-shot Fourier spectroscopic imager for realization of noninvasive blood glucose sensors in smartphones

    Science.gov (United States)

    Kawashima, Natsumi; Nogo, Kosuke; Hosono, Satsuki; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro

    2016-11-01

    The use of the wide-field-stop and beam-expansion method for sensitivity enhancement of one-shot Fourier spectroscopy is proposed to realize health care sensors installed in smartphones for daily monitoring. When measuring the spectral components of human bodies noninvasively, diffuse reflected light from biological membranes is too weak for detection using conventional hyperspectral cameras. One-shot Fourier spectroscopy is a spatial phase-shift-type interferometer that can determine the one-dimensional spectral characteristics from a single frame. However, this method has low sensitivity, so that only the spectral characteristics of light sources with direct illumination can be obtained, because a single slit is used as a field stop. The sensitivity of the proposed spectroscopic method is improved by using the wide-field-stop and beam-expansion method. The use of a wider field stop slit width increases the detected light intensity; however, this simultaneously narrows the diffraction angle. The narrower collimated objective beam diameter degrades the visibility of interferograms. Therefore, a plane-concave cylindrical lens between the objective plane and the single slit is introduced to expand the beam diameter. The resulting sensitivity improvement achieved when using the wide-field-stop and beam-expansion method allows the spectral characteristics of hemoglobin to be obtained noninvasively from a human palm using a midget lamp.

  8. Coherent-light-boosted, sub-shot noise, quantum interferometry

    Energy Technology Data Exchange (ETDEWEB)

    Plick, William N; Dowling, Jonathan P [Hearne Institute for Theoretical Physics, Department of Physics and Astronomy, Louisiana State University, Baton Rouge, LA 70803 (United States); Agarwal, Girish S, E-mail: bplick@yahoo.co [Department of Physics, Oklahoma State University, Stillwater, OK 74078 (United States)

    2010-08-15

    We present in this paper a new scheme for optical interferometry. We utilize coherent-beam-stimulated two-mode squeezed light, which interacts with a phase shifter and is then squeezed again before detection. Our theoretical device has the potential to reach far below the shot-noise limit in phase sensitivity. This new proposal avoids the pitfalls of other setups, such as difficulty in creating the required resource. Furthermore, our scheme requires no complicated detection protocol, relying instead only on simple intensity measurement. Also, bright, coherent sources 'boost' squeezed light, creating a very sensitive device. This hybrid scheme relies on no unknown components and can be constructed with current technology. In this paper, we present our analysis of this relatively straightforward device, using the operator propagation method. We derive the phase sensitivity and provide a simple numerical example of the power of our new proposal. Sensitivity to unknown phase shifts scales as a shot-noise-limited Mach-Zehnder interferometer, multiplied by a sub-Heisenberg contribution from the squeezed light.

  9. Coherent-light-boosted, sub-shot noise, quantum interferometry

    International Nuclear Information System (INIS)

    Plick, William N; Dowling, Jonathan P; Agarwal, Girish S

    2010-01-01

    We present in this paper a new scheme for optical interferometry. We utilize coherent-beam-stimulated two-mode squeezed light, which interacts with a phase shifter and is then squeezed again before detection. Our theoretical device has the potential to reach far below the shot-noise limit in phase sensitivity. This new proposal avoids the pitfalls of other setups, such as difficulty in creating the required resource. Furthermore, our scheme requires no complicated detection protocol, relying instead only on simple intensity measurement. Also, bright, coherent sources 'boost' squeezed light, creating a very sensitive device. This hybrid scheme relies on no unknown components and can be constructed with current technology. In this paper, we present our analysis of this relatively straightforward device, using the operator propagation method. We derive the phase sensitivity and provide a simple numerical example of the power of our new proposal. Sensitivity to unknown phase shifts scales as a shot-noise-limited Mach-Zehnder interferometer, multiplied by a sub-Heisenberg contribution from the squeezed light.

  10. Caffeine Content in Popular Energy Drinks and Energy Shots.

    Science.gov (United States)

    Attipoe, Selasi; Leggit, Jeffrey; Deuster, Patricia A

    2016-09-01

    The use of energy beverages is high among the general population and military personnel. Previous studies have reported discrepancies between the actual amount of caffeine in products and the amount of caffeine on stated labels. Thus, the purpose of this study was to examine the content of caffeine listed on the labels of various energy drinks and energy shots. Top-selling energy drinks (n = 9) and energy shots (n = 5) were purchased from retail stores. Three of each of the 14 products were purchased and analyzed for caffeine content by an independent laboratory. Of the 14 products tested, 5 did not provide caffeine amounts on their facts panel-of those, 3 listed caffeine as an ingredient and 2 listed caffeine as part of a proprietary blend. The remaining 9 (of 14) products stated the amounts of caffeine on their labels, all of which were within 15% of the amount indicated on the label. In this study, although the energy beverages that indicated the amount of caffeine it contained had values within ±15% of the amount listed on the label, a potentially acceptable range, this finding is not acceptable with regard to current labeling regulations, which require added ingredients to total 100%. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  11. SunShot 2030 for Photovoltaics (PV): Envisioning a Low-cost PV Future

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Wesley J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Frew, Bethany A. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gagnon, Pieter J. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Richards, James [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sun, Yinong [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margolis, Robert M. [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Woodhouse, Michael A. [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-09-12

    In this report we summarize the implications, impacts, and deployment potential of reaching the SunShot 2030 targets for the electricity system in the contiguous United States. We model 25 scenarios of the U.S. power sector using the Regional Energy Deployment Systems (ReEDS) and Distributed Generation (dGen) capacity expansion models. The scenarios cover a wide range of sensitivities to capture future uncertainties relating to fuel prices, retirements, renewable energy capital costs, and load growth. We give special attention to the potential for storage costs to also rapidly decline due to its large synergies with low-cost solar. The ReEDS and dGen models project utility- and distributed-scale power sector evolution, respectively, for the United States. Both models have been designed with special emphasis on capturing the unique traits of renewable energy, including variability and grid integration requirements. Across the suite of scenarios modeled, we find that reaching the SunShot 2030 target has the potential to lead to significant capacity additions of PV in the United States. By 2050, PV penetration levels are projected to reach 28-46 percent of total generation. If storage also sees significant reductions in cost, then the 2050 solar penetration levels could reach 41-64 percent. PV deployment is projected to occur in all of the lower 48 states, though the specific deployment level is scenario dependent. The growth in PV is projected to be dominated by utility-scale systems, but the actual mix between utility and distributed systems could ultimately vary depending on how policies, system costs, and rate structures evolve.

  12. Single-Tube Reaction Using Perfluorocarbons: A Prerequisite Step Leading to the Whole-Slide In Situ Technique on Histopathological Slides.

    Directory of Open Access Journals (Sweden)

    Yi-Chang Chen

    Full Text Available Developing a robust, novel method for performing multiple reactions in a single tube is not only time- and cost-saving but also critical for future high-throughput whole-slide in situ techniques on diseased tissues. In this study, we introduce the use of perfluorocarbons and compound-coated magnetic particles to create pseudochambers in a single tube, allowing different reactions to be performed in different phases. Perfluorocarbons also serve as cell lysis buffer and polymerase chain reaction (PCR buffer owing to their highly penetrating, repellent and emulsifiable properties. Using this method, nucleic acids can be isolated and purified from various sample types and sizes, followed by PCR, real-time PCR, or multiplex PCR in the same tube. No incubation or enzyme digesting time is needed and the risk of cross-contamination is reduced. Tests can be performed in microemulsions (water-in-oil droplets containing sequence-specific captures and probes for further high-throughput detection. We present a simple, quick, and robust procedure as a prerequisite step to future high-throughput in situ techniques.

  13. Infectious complications as the leading cause of death after kidney transplantation: analysis of more than 10,000 transplants from a single center.

    Science.gov (United States)

    de Castro Rodrigues Ferreira, Flávio; Cristelli, Marina Pontello; Paula, Mayara Ivani; Proença, Henrique; Felipe, Claudia Rosso; Tedesco-Silva, Helio; Medina-Pestana, José Osmar

    2017-08-01

    To identify specific causes of graft failure in a large sample of kidney transplant patients from a middle-income, developing country. Retrospective cohort study analyzing all consecutive single kidney transplants (KTs) performed at a single center in Brazil between January 1st 1998 and December 31st 2013. The database closing date was December 31st 2014. Out of 10,400 KTs, there were 1191 (11.45%) deaths with a functioning graft, 40 cases (0.38%) of primary non-function (PNF) and 1417 cases (13.62%) of graft loss excluding death and PNF as the cause. Infectious complications (404 cases, 34% of all deaths) were the major cause of death. Most deaths due to infection occurred within the first year after transplantation (157 deaths, 38.86%). Immunologic mechanisms, comprising acute rejection and immune-mediated interstitial fibrosis/tubular atrophy (IF/TA), were responsible for 52% of all cases of graft failure not involving recipient death. Half of the losses by acute rejection occurred late after transplantation. Contrary to what is observed in developed countries, infectious complications are the main challenge with kidney transplantation in Brazil. Non-adherence to treatment also appears to contribute significantly to long-term kidney graft loss. Strategies for improvement should focus on better compliance and a greater safety profile of immunosuppressive treatment.

  14. Lead sources in human diet in Greenland

    DEFF Research Database (Denmark)

    Bjerregaard, Peter; Johansen, Poul; Mulvad, Gert

    2004-01-01

    Although blood lead levels have declined in Greenland, they are still elevated despite the fact that lead levels in the Greenland environment are very low. Fragments of lead shot in game birds have been suggested as an important source of dietary exposure, and meals of sea birds, particularly eider......, contain high concentrations of lead. In a cross-sectional population survey in Greenland in 1993-1994, blood lead adjusted for age and sex was found to be associated with the reported consumption of sea birds. Participants reporting less than weekly intake of sea birds had blood lead concentrations...... of approximately 75 microg/L, whereas those who reported eating sea birds several times a week had concentrations of approximately 110 microg/L, and those who reported daily intake had concentrations of 170 microg/L (p = 0.01). Blood lead was not associated with dietary exposure to other local or imported food...

  15. Microscopic understanding of spin current probed by shot noise

    Science.gov (United States)

    Arakawa, Tomonori

    The spin currents is one of key issue in the spintronics field and the generation and detection of those have been intensively studied by using various materials. The analysis of experiments, however, relies on phenomenological parameters such as spin relaxation length and spin flip time. The microscopic nature of the spin current such as energy distribution and energy relaxation mechanism, has not yet well understood. To establish a better microscopic understanding of spin currents, I focused on the shot noise measurement which is well established technique in the field of mesoscopic physics [Y. M. Blanter and M. B üttiker, Phys. Rep. 336, 1 (2000).]. Although there are many theoretically works about shot noise in the presence of spin currents, for example detection of spin accumulation [J. Meair, P. Stano, and P. Jacquod, Phys. Rev. B 84 (2011).], estimation of spin flip currents, and so on, these predictions have never been experimentally confirmed. In this context, we reported the first experimental detention of shot noise in the presence of the spin accumulation in a (Ga,Mn)As/tunnel barrier/n-GaAs based lateral spin valve device [T. Arakawa et al., Phys. Rev. Lett. 114, 016601 (2015).]. Together with this result, we found however that the effective temperature of the spin current drastically increases due to the spin injection process. This heating of electron system could be a big problem to realize future spin current devices by using quantum coherence, because the effective temperature rise directly related to the destruction of the coherence of the spin current. Therefore, then we focused on the mechanism of this heating and the energy relaxation in a diffusive channel. By measuring current noise and the DC offset voltage in the usual non-local spin valve signal as a function of the spin diffusion channel length, we clarified that the electron-electron interaction length, which is the characteristic length for the relaxation of the electron system, is

  16. Novel single base-pair deletion in exon 1 of XK gene leading to McLeod syndrome with chorea, muscle wasting, peripheral neuropathy, acanthocytosis and haemolysis.

    Science.gov (United States)

    Wiethoff, Sarah; Xiromerisiou, Georgia; Bettencourt, Conceição; Kioumi, Anna; Tsiptsios, Iakovos; Tychalas, Athanasios; Evaggelia, Markousi; George, Kaltsounis; Makris, Vasileios; Hardy, John; Houlden, Henry

    2014-04-15

    We present a 70-year-old male patient of Greek origin with choreatic movements of the tongue and face, lower limb muscle weakness, peripheral neuropathy, elevated creatinephosphokinase (CPK), acanthocytosis and haemolysis in the absence of Kell RBC antigens with an additional Factor IX-deficiency. Genetic testing for mutations in the three exons of the XK gene revealed a previously unreported hemizygous single base-pair frameshift deletion at exon 1 (c.229delC, p.Leu80fs). In conclusion, we hereby describe a rare phenotype of a patient with McLeod syndrome which was discovered coincidentally during routine blood group testing and consecutively genetically confirmed. Copyright © 2014 The Authors. Published by Elsevier B.V. All rights reserved.

  17. A vaccinia virus recombinant transcribing an alphavirus replicon and expressing alphavirus structural proteins leads to packaging of alphavirus infectious single cycle particles.

    Directory of Open Access Journals (Sweden)

    Juana M Sánchez-Puig

    Full Text Available Poxviruses and Alphaviruses constitute two promising viral vectors that have been used extensively as expression systems, or as vehicles for vaccine purposes. Poxviruses, like vaccinia virus (VV are well-established vaccine vectors having large insertion capacity, excellent stability, and ease of administration. In turn, replicons derived from Alphaviruses like Semliki Forest virus (SFV are potent protein expression and immunization vectors but stocks are difficult to produce and maintain. In an attempt to demonstrate the use of a Poxvirus as a means for the delivery of small vaccine vectors, we have constructed and characterized VV/SFV hybrid vectors. A SFV replicon cDNA was inserted in the VV genome and placed under the control of a VV early promoter. The replicon, transcribed from the VV genome as an early transcript, was functional, and thus capable of initiating its own replication and transcription. Further, we constructed a VV recombinant additionally expressing the SFV structural proteins under the control of a vaccinia synthetic early/late promoter. Infection with this recombinant produced concurrent transcription of the replicon and expression of SFV structural proteins, and led to the generation of replicon-containing SFV particles that were released to the medium and were able to infect additional cells. This combined VV/SFV system in a single virus allows the use of VV as a SFV delivery vehicle in vivo. The combination of two vectors, and the possibility of generating in vivo single-cycle, replicon containing alphavirus particles, may open new strategies in vaccine development or in the design of oncolytic viruses.

  18. A vaccinia virus recombinant transcribing an alphavirus replicon and expressing alphavirus structural proteins leads to packaging of alphavirus infectious single cycle particles.

    Science.gov (United States)

    Sánchez-Puig, Juana M; Lorenzo, María M; Blasco, Rafael

    2013-01-01

    Poxviruses and Alphaviruses constitute two promising viral vectors that have been used extensively as expression systems, or as vehicles for vaccine purposes. Poxviruses, like vaccinia virus (VV) are well-established vaccine vectors having large insertion capacity, excellent stability, and ease of administration. In turn, replicons derived from Alphaviruses like Semliki Forest virus (SFV) are potent protein expression and immunization vectors but stocks are difficult to produce and maintain. In an attempt to demonstrate the use of a Poxvirus as a means for the delivery of small vaccine vectors, we have constructed and characterized VV/SFV hybrid vectors. A SFV replicon cDNA was inserted in the VV genome and placed under the control of a VV early promoter. The replicon, transcribed from the VV genome as an early transcript, was functional, and thus capable of initiating its own replication and transcription. Further, we constructed a VV recombinant additionally expressing the SFV structural proteins under the control of a vaccinia synthetic early/late promoter. Infection with this recombinant produced concurrent transcription of the replicon and expression of SFV structural proteins, and led to the generation of replicon-containing SFV particles that were released to the medium and were able to infect additional cells. This combined VV/SFV system in a single virus allows the use of VV as a SFV delivery vehicle in vivo. The combination of two vectors, and the possibility of generating in vivo single-cycle, replicon containing alphavirus particles, may open new strategies in vaccine development or in the design of oncolytic viruses.

  19. 75 FR 58377 - Lead in Ammunition and Fishing Sinkers; Disposition of TSCA Section 21 Petition

    Science.gov (United States)

    2010-09-24

    ... ENVIRONMENTAL PROTECTION AGENCY [EPA-HQ-OPPT-2010-0681; FRL-8847-5] Lead in Ammunition and Fishing..., and distribution in commerce of (1) lead bullets and shot; and (2) lead fishing sinkers. On August 27... Chemicals Division (7404T), Office of Pollution Prevention and Toxics, Environmental Protection Agency, 1200...

  20. Shot noise in systems with semi-Dirac points

    International Nuclear Information System (INIS)

    Zhai, Feng; Wang, Juan

    2014-01-01

    We calculate the ballistic conductance and shot noise of electrons through a two-dimensional stripe system (width W ≫ length L) with semi-Dirac band-touching points. We find that the ratio between zero-temperature noise power and mean current (the Fano factor) is highly anisotropic. When the transport is along the linear-dispersion direction and the Fermi energy is fixed at the semi-Dirac point, the Fano factor has a universal value F = 0.179 while a minimum conductivity exists and scales with L 1∕2 . Along the parabolic dispersion direction, the Fano factor at the semi-Dirac point has a contact-independent limit exceeding 0.9, which varies weakly with L due to the common-path interference of evanescent waves. Our findings suggest a way to discern the type of band-touching points