WorldWideScience

Sample records for single large volume

  1. Mechanical properties of ANTRIX balloon film and fabrication of single cap large volume balloons

    Science.gov (United States)

    Suneel Kumar, B.; Sreenivasan, S.; Subba Rao, J. V.; Manchanda, R. K.

    2008-11-01

    The zero pressure plastic balloons used for high altitude studies are generally made from polyethylene material. Tensile properties of the thin film polymer are the key parameters for material selection due to extremely low temperature of -90 °C encountered by the balloons in the tropopause region during the ascent at equatorial latitudes. The physical and structural properties of the material determine the uniformity of the stress distribution over the entire shell. Load stresses from the suspended load propagate via load tapes heat sealed along with the gore seals as per the balloon design. A balance between this heat seal strength and the film strength is a desirable property of the basic resin in terms of the bubble strength, gauge uniformity, and long-term storage properties. In addition, the design of the top shell of the balloon and its stress distribution play an important role since only a fraction of the balloon is deployed during the filling operation and the ascent. In this paper we describe the mechanical properties of the 'ANTRIX' film developed by us and the optimized design of single cap balloons, which have been successfully used in our experiments over the past 5 years.

  2. Large volume cryogenic silicon detectors

    International Nuclear Information System (INIS)

    Braggio, C.; Boscardin, M.; Bressi, G.; Carugno, G.; Corti, D.; Galeazzi, G.; Zorzi, N.

    2009-01-01

    We present preliminary measurements for the development of a large volume silicon detector to detect low energy and low rate energy depositions. The tested detector is a one cm-thick silicon PIN diode with an active volume of 31 cm 3 , cooled to the liquid helium temperature to obtain depletion from thermally-generated free carriers. A thorough study has been done to show that effects of charge trapping during drift disappears at a bias field value of the order of 100V/cm.

  3. Large volume cryogenic silicon detectors

    Energy Technology Data Exchange (ETDEWEB)

    Braggio, C. [Dipartimento di Fisica, Universita di Padova, via Marzolo 8, 35131 Padova (Italy); Boscardin, M. [Fondazione Bruno Kessler (FBK), via Sommarive 18, I-38100 Povo (Italy); Bressi, G. [INFN sez. di Pavia, via Bassi 6, 27100 Pavia (Italy); Carugno, G.; Corti, D. [INFN sez. di Padova, via Marzolo 8, 35131 Padova (Italy); Galeazzi, G. [INFN lab. naz. Legnaro, viale dell' Universita 2, 35020 Legnaro (Italy); Zorzi, N. [Fondazione Bruno Kessler (FBK), via Sommarive 18, I-38100 Povo (Italy)

    2009-12-15

    We present preliminary measurements for the development of a large volume silicon detector to detect low energy and low rate energy depositions. The tested detector is a one cm-thick silicon PIN diode with an active volume of 31 cm{sup 3}, cooled to the liquid helium temperature to obtain depletion from thermally-generated free carriers. A thorough study has been done to show that effects of charge trapping during drift disappears at a bias field value of the order of 100V/cm.

  4. Expanding Lorentz and spectrum corrections to large volumes of reciprocal space for single-crystal time-of-flight neutron diffraction.

    Science.gov (United States)

    Michels-Clark, Tara M; Savici, Andrei T; Lynch, Vickie E; Wang, Xiaoping; Hoffmann, Christina M

    2016-04-01

    Evidence is mounting that potentially exploitable properties of technologically and chemically interesting crystalline materials are often attributable to local structure effects, which can be observed as modulated diffuse scattering (mDS) next to Bragg diffraction (BD). BD forms a regular sparse grid of intense discrete points in reciprocal space. Traditionally, the intensity of each Bragg peak is extracted by integration of each individual reflection first, followed by application of the required corrections. In contrast, mDS is weak and covers expansive volumes of reciprocal space close to, or between, Bragg reflections. For a representative measurement of the diffuse scattering, multiple sample orientations are generally required, where many points in reciprocal space are measured multiple times and the resulting data are combined. The common post-integration data reduction method is not optimal with regard to counting statistics. A general and inclusive data processing method is needed. In this contribution, a comprehensive data analysis approach is introduced to correct and merge the full volume of scattering data in a single step, while correctly accounting for the statistical weight of the individual measurements. Development of this new approach required the exploration of a data treatment and correction protocol that includes the entire collected reciprocal space volume, using neutron time-of-flight or wavelength-resolved data collected at TOPAZ at the Spallation Neutron Source at Oak Ridge National Laboratory.

  5. Enhanced performance large volume dissolution-DNP

    DEFF Research Database (Denmark)

    Bowen, Sean; Ardenkjær-Larsen, Jan Henrik

    2014-01-01

    A systematic study of the performance of the dissolution process in dissolution-DNP is presented. A relatively simple set of modifications is made to the standard Hypersense dissolution system to enable polarization of large volume samples. These consist of a large volume sample cup along with su...

  6. Dark radiation in LARGE volume models

    Science.gov (United States)

    Cicoli, Michele; Conlon, Joseph P.; Quevedo, Fernando

    2013-02-01

    We consider reheating driven by volume modulus decays in the LARGE volume scenario. Such reheating always generates nonzero dark radiation through the decays to the axion partner, while the only competitive visible sector decays are Higgs pairs via the Giudice-Masiero term. In the framework of sequestered models where the cosmological moduli problem is absent, the simplest model with a shift-symmetric Higgs sector generates 1.56≤ΔNeff≤1.74. For more general cases, the known experimental bounds on ΔNeff strongly constrain the parameters and matter content of the models.

  7. Electrolyte and Haemogram changes post large volume liposuction comparing two different tumescent solutions

    OpenAIRE

    Vivek, Kumar; Amiti, Shah; Shivshankar, Saha; Lalit, Choudhary

    2014-01-01

    Background: The most common definitions of large volume liposuction refer to total 5 l volume aspiration during a single procedure (fat plus wetting solution). Profound haemodynamic and metabolic alterations can accompany large volume liposuction. Due to paucity of literature on the effect of different tumescent solutions on the electrolyte balance and haematological changes during large volume liposuction, we carried out this study using two different wetting solutions to study the same. Mat...

  8. Large volume monolithic stationary phases: preparation, properties, and applications.

    Science.gov (United States)

    Podgornik, Aleš; Jančar, Janez; Mihelič, Igor; Barut, Miloš; Strancar, Aleš

    2010-03-01

    Monoliths represents the 4th generation of chromatographic supports. They consist of a single piece of highly porous material with interconnected flow through pores. Because of that transport is based on convection what results in a flow unaffected separation and dynamic binding capacity. This is especially important when large molecular weight molecules such as proteins, DNA or viruses have to be purified. For this purpose large volume monolithic columns are needed. In this article preparation of such columns is described together with their main applications. The article is dedicated to Prof. Tine Koloini who substantially contributed to this topic.

  9. Comments on large-N volume independence

    Energy Technology Data Exchange (ETDEWEB)

    Poppitz, Erich; /Toronto U.; Unsal, Mithat; /SLAC /Stanford U., Phys. Dept.

    2010-06-02

    We study aspects of the large-N volume independence on R{sup 3} X L{sup {Gamma}}, where L{sup {Gamma}} is a {Gamma}site lattice for Yang-Mills theory with adjoint Wilson-fermions. We find the critical number of lattice sites above which the center-symmetry analysis on L{sup {Gamma}} agrees with the one on the continuum S{sup 1}. For Wilson parameter set to one and {Gamma}{>=}2, the two analyses agree. One-loop radiative corrections to Wilson-line masses are finite, reminiscent of the UV-insensitivity of the Higgs mass in deconstruction/Little-Higgs theories. Even for theories with {Gamma}=1, volume independence in QCD(adj) may be guaranteed to work by tuning one low-energy effective field theory parameter. Within the parameter space of the theory, at most three operators of the 3d effective field theory exhibit one-loop UV-sensitivity. This opens the analytical prospect to study 4d non-perturbative physics by using lower dimensional field theories (d=3, in our example).

  10. Large scale structure statistics: Finite volume effects

    Science.gov (United States)

    Colombi, S.; Bouchet, F. R.; Schaeffer, R.

    1994-01-01

    We study finite volume effects on the count probability distribution function PN(l) and the averaged Q-body correlations Xi-barQ (2 less than or = Q less than or equal 5). These statistics are computed for cubic cells, of size l. We use as an example the case of the matter distribution of a cold dark matter (CDM) universe involving approximately 3 x 105 particles. The main effect of the finiteness of the sampled volume is to induce an abrupt cut-off on the function PN(l) at large N. This clear signature makes an analysis of the consequences easy, and one can envisage a correction procedure. As a matter of fact, we demonstrate how an unfair sample can strongly affect the estimates of the functions Xi-barQ for Q greater than or = 3 (and decrease the measured zero of the two-body correlation function). We propose a method to correct for this are fact, or at least to evaluate the corresponding errors. We show that the correlations are systematically underestimated by direct measurements. We find that, once corrected, the statistical properties of the CDM universe appear compatible with the scaling relation SQ identically equals Xi-bar2 exp Q-1 = constant with respect to scale, in the non-linear regime; it was not the case with direct measurments. However, we note a deviation from scaling at scales close to the correlation length. It is probably due to the transition between the highly non-linear regime and the weakly correlated regime, where the functions SQ also seem to present a plateau. We apply the same procedure to simulations with hot dark matter (HDM) and white noise initial conditions, with similar results. Our method thus provides the first accurate measurement of the normalized skewness, S3, and the normalized kurtosis, S4, for three typical models of large scale structure formation in an expanding universe.

  11. The parallel volume at large distances

    DEFF Research Database (Denmark)

    Kampf, Jürgen

    In this paper we examine the asymptotic behavior of the parallel volume of planar non-convex bodies as the distance tends to infinity. We show that the difference between the parallel volume of the convex hull of a body and the parallel volume of the body itself tends to . This yields a new proof...... for the fact that a planar body can only have polynomial parallel volume, if it is convex. Extensions to Minkowski spaces and random sets are also discussed....

  12. The parallel volume at large distances

    DEFF Research Database (Denmark)

    Kampf, Jürgen

    In this paper we examine the asymptotic behavior of the parallel volume of planar non-convex bodies as the distance tends to infinity. We show that the difference between the parallel volume of the convex hull of a body and the parallel volume of the body itself tends to 0. This yields a new proof...... for the fact that a planar body can only have polynomial parallel volume, if it is convex. Extensions to Minkowski spaces and random sets are also discussed....

  13. Large volumes and spectroscopy of walking theories

    CERN Document Server

    Del Debbio, L; Patella, A; Pica, C; Rago, A

    2016-01-01

    A detailed investigation of finite size effects is performed for SU(2) gauge theory with two fermions in the adjoint representation, which previous lattice studies have shown to be inside the conformal window. The system is investigated with different spatial and temporal boundary conditions on lattices of various spatial and temporal extensions, for two values of the bare fermion mass representing a {\\em heavy} and {\\em light} fermion regime. Our study shows that the infinite volume limit of masses and decay constants in the mesonic sector is reached only when the mass of the pseudoscalar particle $M_\\mathrm{PS}$ and the spatial lattice size $L$ satisfy the relation $L M_\\mathrm{PS} \\ge 15$. This bound, which is at least a factor of three higher than what observed in QCD, is a likely consequence of the different spectral signatures of the two theories, with the scalar isosinglet ($0^{++}$ glueball) being the lightest particle in our model. In addition to stressing the importance of simulating large lattice s...

  14. Volume independence in large Nc QCD-like gauge theories

    International Nuclear Information System (INIS)

    Kovtun, Pavel; Uensal, Mithat; Yaffe, Laurence G.

    2007-01-01

    Volume independence in large N c gauge theories may be viewed as a generalized orbifold equivalence. The reduction to zero volume (or Eguchi-Kawai reduction) is a special case of this equivalence. So is temperature independence in confining phases. A natural generalization concerns volume independence in 'theory space' of quiver gauge theories. In pure Yang-Mills theory, the failure of volume independence for sufficiently small volumes (at weak coupling) due to spontaneous breaking of center symmetry, together with its validity above a critical size, nicely illustrate the symmetry realization conditions which are both necessary and sufficient for large N c orbifold equivalence. The existence of a minimal size below which volume independence fails also applies to Yang-Mills theory with antisymmetric representation fermions [QCD(AS)]. However, in Yang-Mills theory with adjoint representation fermions [QCD(Adj)], endowed with periodic boundary conditions, volume independence remains valid down to arbitrarily small size. In sufficiently large volumes, QCD(Adj) and QCD(AS) have a large N c ''orientifold'' equivalence, provided charge conjugation symmetry is unbroken in the latter theory. Therefore, via a combined orbifold-orientifold mapping, a well-defined large N c equivalence exists between QCD(AS) in large, or infinite, volume and QCD(Adj) in arbitrarily small volume. Since asymptotically free gauge theories, such as QCD(Adj), are much easier to study (analytically or numerically) in small volume, this equivalence should allow greater understanding of large N c QCD in infinite volume

  15. Effects of uncertainty in model predictions of individual tree volume on large area volume estimates

    Science.gov (United States)

    Ronald E. McRoberts; James A. Westfall

    2014-01-01

    Forest inventory estimates of tree volume for large areas are typically calculated by adding model predictions of volumes for individual trees. However, the uncertainty in the model predictions is generally ignored with the result that the precision of the large area volume estimates is overestimated. The primary study objective was to estimate the effects of model...

  16. Preface to the volume Large Rivers

    Science.gov (United States)

    Latrubesse, Edgardo M.; Abad, Jorge D.

    2018-02-01

    The study and knowledge of the geomorphology of large rivers increased significantly during the last years and the factors that triggered these advances are multiple. On one hand, modern technologies became more accessible and their disseminated usage allowed the collection of data from large rivers as never seen before. The generalized use of high tech data collection with geophysics equipment such as acoustic Doppler current profilers-ADCPs, multibeam echosounders, plus the availability of geospatial and computational tools for morphodynamics, hydrological and hydrosedimentological modeling, have accelerated the scientific production on the geomorphology of large rivers at a global scale. Despite the advances, there is yet a lot of work ahead. Good parts of the large rivers are in the tropics and many are still unexplored. The tropics also hold crucial fluvial basins that concentrate good part of the gross domestic product of large countries like the Parana River in Argentina and Brazil, the Ganges-Brahmaputra in India, the Indus River in Pakistan, and the Mekong River in several countries of South East Asia. The environmental importance of tropical rivers is also outstanding. They hold the highest biodiversity of fluvial fauna and alluvial vegetation and many of them, particularly those in Southeast Asia, are among the most hazardous systems for floods in the entire world. Tropical rivers draining mountain chains such as the Himalaya, the Andes and insular Southeast Asia are also among the most heavily sediment loaded rivers and play a key role in both the storage of sediment at continental scale and the transference of sediments from the continent to the Ocean at planetary scale (Andermann et al., 2012; Latrubesse and Restrepo, 2014; Milliman and Syvitski, 1992; Milliman and Farsnworth, 2011; Sinha and Friend, 1994).

  17. SUSY’s Ladder: reframing sequestering at Large Volume

    Energy Technology Data Exchange (ETDEWEB)

    Reece, Matthew [Department of Physics, Harvard University,Cambridge, MA 02138 (United States); Xue, Wei [Center for Theoretical Physics, Massachusetts Institute of Technology,Cambridge, MA 02139 (United States)

    2016-04-07

    Theories with approximate no-scale structure, such as the Large Volume Scenario, have a distinctive hierarchy of multiple mass scales in between TeV gaugino masses and the Planck scale, which we call SUSY’s Ladder. This is a particular realization of Split Supersymmetry in which the same small parameter suppresses gaugino masses relative to scalar soft masses, scalar soft masses relative to the gravitino mass, and the UV cutoff or string scale relative to the Planck scale. This scenario has many phenomenologically interesting properties, and can avoid dangers including the gravitino problem, flavor problems, and the moduli-induced LSP problem that plague other supersymmetric theories. We study SUSY’s Ladder using a superspace formalism that makes the mysterious cancelations in previous computations manifest. This opens the possibility of a consistent effective field theory understanding of the phenomenology of these scenarios, based on power-counting in the small ratio of string to Planck scales. We also show that four-dimensional theories with approximate no-scale structure enforced by a single volume modulus arise only from two special higher-dimensional theories: five-dimensional supergravity and ten-dimensional type IIB supergravity. This gives a phenomenological argument in favor of ten dimensional ultraviolet physics which is different from standard arguments based on the consistency of superstring theory.

  18. Effect Sizes in Single Case Research: How Large is Large?

    Science.gov (United States)

    Parker, Richard I.; Brossart, Daniel F.; Vannest, Kimberly J.; Long, James R.; De-Alba, Roman Garcia; Baugh, Frank G.; Sullivan, Jeremy R.

    2005-01-01

    This study examined the problem of interpreting effect sizes in single case research. Nine single case analytic techniques were applied to a convenience sample of 77 published interrupted time series (AB) datasets, and the results were compared by technique across the datasets. Reanalysis of the published data helped answer questions about the…

  19. New large volume Calabi-Yau threefolds

    Science.gov (United States)

    Altman, Ross; He, Yang-Hui; Jejjala, Vishnu; Nelson, Brent D.

    2018-02-01

    In previous work, we have commenced the task of unpacking the 473 800 776 reflexive polyhedra by Kreuzer and Skarke into a database of Calabi-Yau threefolds [R. Altman et al. J. High Energy Phys. 02 (2015) 158., 10.1007/JHEP02(2015)158] (see www.rossealtman.com). In this paper, following a pedagogical introduction, we present a new algorithm to isolate Swiss cheese solutions characterized by "holes," or small 4-cycles, descending from the toric divisors inherent to the original four dimensional reflexive polyhedra. Implementing these methods, we find 2268 explicit Swiss cheese manifolds, over half of which have h1 ,1=6 . Many of our solutions have multiple large cycles. Such Swiss cheese geometries facilitate moduli stabilization in string compactifications and provide flat directions for cosmological inflation.

  20. Large volume continuous counterflow dialyzer has high efficiency

    Science.gov (United States)

    Mandeles, S.; Woods, E. C.

    1967-01-01

    Dialyzer separates macromolecules from small molecules in large volumes of solution. It takes advantage of the high area/volume ratio in commercially available 1/4-inch dialysis tubing and maintains a high concentration gradient at the dialyzing surface by counterflow.

  1. Large-Volume Gravid Traps Enhance Collection of Culex Vectors.

    Science.gov (United States)

    Popko, David A; Walton, William E

    2016-06-01

    Gravid mosquito collections were compared among several large-volume (infusion volume ≥35 liters) gravid trap designs and the small-volume (infusion volume  =  6 liters) Centers for Disease Control and Prevention (CDC) gravid trap used routinely by vector control districts for vector and pathogen surveillance. The numbers of gravid Culex quinquefasciatus, Cx. tarsalis, and Cx. stigmatosoma collected by large gravid traps were greater than by the CDC gravid trap during nearly all overnight trials. Large-volume gravid traps collected on average 6.6-fold more adult female Culex mosquitoes compared to small-volume CDC gravid traps across 3 seasons during the 3 years of the studies. The differences in gravid mosquito collections between large-versus small-volume gravid traps were greatest during spring, when 8- to 56-fold more Culex individuals were collected using large-volume gravid traps. The proportion of gravid females in collections did not differ appreciably among the more effective trap designs tested. Important determinants of gravid trap performance were infusion container size and type as well as infusion volume, which determined the distance between the suction trap and the infusion surface. Of lesser importance for gravid trap performance were the number of suction traps, method of suction trap mounting, and infusion concentration. Fermentation of infusions between 1 and 4 wk weakly affected total mosquito collections, with Cx. stigmatosoma collections moderately enhanced by comparatively young and organically enriched infusions. A suction trap mounted above 100 liters of organic infusion housed in a 121-liter black plastic container collected the most gravid mosquitoes over the greatest range of experimental conditions, and a 35-liter infusion with side-mounted suction traps was a promising lesser-volume alternative design.

  2. Volume measurement study for large scale input accountancy tank

    International Nuclear Information System (INIS)

    Uchikoshi, Seiji; Watanabe, Yuichi; Tsujino, Takeshi

    1999-01-01

    Large Scale Tank Calibration (LASTAC) facility, including an experimental tank which has the same volume and structure as the input accountancy tank of Rokkasho Reprocessing Plant (RRP) was constructed in Nuclear Material Control Center of Japan. Demonstration experiments have been carried out to evaluate a precision of solution volume measurement and to establish the procedure of highly accurate pressure measurement for a large scale tank with dip-tube bubbler probe system to be applied to the input accountancy tank of RRP. Solution volume in a tank is determined from substitution the solution level for the calibration function obtained in advance, which express a relation between the solution level and its volume in the tank. Therefore, precise solution volume measurement needs a precise calibration function that is determined carefully. The LASTAC calibration experiments using pure water showed good result in reproducibility. (J.P.N.)

  3. Characterization of segmented large volume, high purity germanium detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bruyneel, B. [Koeln Univ. (Germany). Inst. fuer Kernphysik

    2006-07-01

    {gamma}-ray tracking in future HPGe arrays like AGATA will rely on pulse shape analysis (PSA) of multiple {gamma}-interactions. For this purpose, a simple and fast procedure was developed which enabled the first full characterization of a segmented large volume HPGe detector. An analytical model for the hole mobility in a Ge crystal lattice was developed to describe the hole drift anisotropy with experimental velocity values along the crystal axis as parameters. The new model is based on the drifted Maxwellian hole distribution in Ge. It is verified by reproducing successfully experimental longitudinal hole anisotropy data. A comparison between electron and hole mobility shows large differences for the longitudinal and tangential velocity anisotropy as a function of the electrical field orientation. Measurements on a 12 fold segmented, n-type, large volume, irregular shaped HPGe detector were performed in order to determine the parameters of anisotropic mobility for electrons and holes as charge carriers created by {gamma}-ray interactions. To characterize the electron mobility the complete outer detector surface was scanned in small steps employing photopeak interactions at 60 keV. A precise measurement of the hole drift anisotropy was performed with 356 keV rays. The drift velocity anisotropy and crystal geometry cause considerable rise time differences in pulse shapes depending on the position of the spatial charge carrier creation. Pulse shapes of direct and transient signals are reproduced by weighting potential calculations with high precision. The measured angular dependence of rise times is caused by the anisotropic mobility, crystal geometry, changing field strength and space charge effects. Preamplified signals were processed employing digital spectroscopy electronics. Response functions, crosstalk contributions and averaging procedures were taken into account implying novel methods due to the segmentation of the Ge-crystal and the digital electronics

  4. Single incision pediatric endoscopic surgery: advantages of relatively large incision

    International Nuclear Information System (INIS)

    Yilmaz, E.; Afsarlar, E.; Karaman, I.

    2015-01-01

    To describe Single Incision Pediatric Endoscopic Surgery (SIPES) performed on children with various diagnoses, emphasizing its advantages. Study Design: An observational case series. Place and Duration of Study: Department of Pediatric Surgery, Dr. Sami Ulus Maternity and Child Health Hospital, Ankara, Turkey, from January 2011 to November 2014. Methodology: A review of patient charts was conducted in which SIPES was preferred as the surgical procedure. Patient demographics, operative details, operative time, clinical outcomes, postoperative pain and cosmesis were analyzed. Results: SIPES was performed on 45 patients (21 girls, 24 boys). Thirty-three appendectomies, 5 varicocelectomies, 3 oophorectomies, 2 ovarian and one paratubal cyst excision, and one fallopian tube excision were performed. All except one procedures were performed through our standard 2cm umbilical vertical or smile incision. In 18 cases, abdominal irrigation/aspiration was easily performed through the existing larger incision, as is done with open surgical technique. None of the patients had early postoperative shoulder/back pain since complete disinflation of CO/sub 2/ could be ensured. All of the patients/parents were satisfied with the cosmesis. Conclusion: SIPES has the advantages of limiting the surgical scar to within the umbilicus and providing easy disinflation of CO/sub 2/, allowing intraabdominal cleaning and extraction of large volume tissue samples through a single large umbilical incision. (author)

  5. Overview of ESO Large Single Dish Study

    Science.gov (United States)

    Testi, Leonardo

    2018-01-01

    In this talk I will briefly summarize the motivation, methodology and outcome of the ESO Submm Single Dish Strategy WG. The WG was established by the ESO Director for Science and completed its work at the end of 2015. I will summarize the status of the report recommendations, which, among other things, led to the organization of the AtLAST workshop.

  6. Higgs, moduli problem, baryogenesis and large volume compactifications

    Energy Technology Data Exchange (ETDEWEB)

    Higaki, Tetsutaro [RIKEN Nishina Center, Saitama (Japan). Mathematical Physics Lab.; Kamada, Kohei [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Takahashi, Fuminobu [Tohoku Univ., Sendai (Japan). Dept. of Physics

    2012-07-15

    We consider the cosmological moduli problem in the context of high-scale supersymmetry breaking suggested by the recent discovery of the standard-model like Higgs boson. In order to solve the notorious moduli-induced gravitino problem, we focus on the LARGE volume scenario, in which the modulus decay into gravitinos can be kinematically forbidden. We then consider the Affleck-Dine mechanism with or without an enhanced coupling with the inflaton, taking account of possible Q-ball formation. We show that the baryon asymmetry of the present Universe can be generated by the Affleck-Dine mechanism in LARGE volume scenario, solving the moduli and gravitino problems.

  7. Higgs, moduli problem, baryogenesis and large volume compactifications

    International Nuclear Information System (INIS)

    Higaki, Tetsutaro; Takahashi, Fuminobu

    2012-07-01

    We consider the cosmological moduli problem in the context of high-scale supersymmetry breaking suggested by the recent discovery of the standard-model like Higgs boson. In order to solve the notorious moduli-induced gravitino problem, we focus on the LARGE volume scenario, in which the modulus decay into gravitinos can be kinematically forbidden. We then consider the Affleck-Dine mechanism with or without an enhanced coupling with the inflaton, taking account of possible Q-ball formation. We show that the baryon asymmetry of the present Universe can be generated by the Affleck-Dine mechanism in LARGE volume scenario, solving the moduli and gravitino problems.

  8. Managing Large-Volume Literature Searches in Research Synthesis Studies

    Science.gov (United States)

    Havill, Nancy L.; Leeman, Jennifer; Shaw-Kokot, Julia; Knafl, Kathleen; Crandell, Jamie; Sandelowski, Margarete

    2014-01-01

    Background Systematic reviews typically require searching for, retrieving, and screening a large volume of literature, yet little guidance is available on how to manage this volume. Purpose We detail methods used to search for and manage the yield of relevant citations for a mixed-methods mixed research synthesis study focused on the intersection between family life and childhood chronic physical conditions. Method We designed inclusive search strings and searched nine bibliographic databases to identify relevant research regardless of methodological origin. We customized searches to individual databases, developed workarounds for transferring large volumes of citations and eliminating duplicate citations using reference management software, and used this software as a portal to select citations for inclusion or exclusion. We identified 67,555 citations, retrieved and screened 3,617 reports, and selected 802 reports for inclusion. Discussion/Conclusions Systematic reviews require search procedures to allow consistent and comprehensive approaches and the ability to work around technical obstacles. PMID:24345615

  9. Melt Electrospinning Writing of Highly Ordered Large Volume Scaffold Architectures.

    Science.gov (United States)

    Wunner, Felix M; Wille, Marie-Luise; Noonan, Thomas G; Bas, Onur; Dalton, Paul D; De-Juan-Pardo, Elena M; Hutmacher, Dietmar W

    2018-04-10

    The additive manufacturing of highly ordered, micrometer-scale scaffolds is at the forefront of tissue engineering and regenerative medicine research. The fabrication of scaffolds for the regeneration of larger tissue volumes, in particular, remains a major challenge. A technology at the convergence of additive manufacturing and electrospinning-melt electrospinning writing (MEW)-is also limited in thickness/volume due to the accumulation of excess charge from the deposited material repelling and hence, distorting scaffold architectures. The underlying physical principles are studied that constrain MEW of thick, large volume scaffolds. Through computational modeling, numerical values variable working distances are established respectively, which maintain the electrostatic force at a constant level during the printing process. Based on the computational simulations, three voltage profiles are applied to determine the maximum height (exceeding 7 mm) of a highly ordered large volume scaffold. These thick MEW scaffolds have fully interconnected pores and allow cells to migrate and proliferate. To the best of the authors knowledge, this is the first study to report that z-axis adjustment and increasing the voltage during the MEW process allows for the fabrication of high-volume scaffolds with uniform morphologies and fiber diameters. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. A bulk inflaton from large-volume extra dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Greene, Brian, E-mail: greene@physics.columbia.ed [Institute for Strings, Cosmology and Astroparticle Physics (ISCAP), Columbia University, New York, NY 10027 (United States); Departments of Physics and Mathematics, Columbia University, New York, NY 10027 (United States); Kabat, Daniel, E-mail: daniel.kabat@lehman.cuny.ed [Department of Physics and Astronomy, Lehman College, CUNY, Bronx, NY 10468 (United States); Levin, Janna, E-mail: janna@astro.columbia.ed [Institute for Strings, Cosmology and Astroparticle Physics (ISCAP), Columbia University, New York, NY 10027 (United States); Department of Physics and Astronomy, Barnard College, Columbia University, New York, NY 10027 (United States); Thurston, Dylan, E-mail: dpt@cpw.math.columbia.ed [Department of Mathematics, Barnard College, Columbia University, New York, NY 10027 (United States)

    2011-01-03

    The universe may have extra spatial dimensions with large volume that we cannot perceive because the energy required to excite modes in the extra directions is too high. Many examples are known of manifolds with a large volume and a large mass gap. These compactifications can help explain the weakness of four-dimensional gravity and, as we show here, they also have the capacity to produce reasonable potentials for an inflaton field. Modeling the inflaton as a bulk scalar field, it becomes very weakly coupled in four dimensions and this enables us to build phenomenologically acceptable inflationary models with tunings at the few per mil level. We speculate on dark matter candidates and the possibility of braneless models in this setting.

  11. Performances of large volume p-type HPGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Bellia, G.; Del Zoppo, A.; Migneco, E.; Sapienza, P. (Istituto Nazionale di Fisica Nucleare, Catania (Italy). Lab. Nazionale del Sud Catania Univ. (Italy). Dipt. di Fisica); Agodi, C.; Alba, R.; Coniglione, R. (Istituto Nazionale di Fisica Nucleare, Catania (Italy). Lab. Nazionale del Sud); Russo, G. (Catania Univ. (Italy). Dipt. di Fisica Istituto Nazionale di Fisica Nucleare, Catania (Italy))

    1989-12-01

    The performances of large volume (about 350 cm{sup 3} and relative efficiency greater than 75%) p-type HPGe detectors are reported. The response function to {gamma}-rays up to 11.67 MeV, the energy dependence of the full energy detection efficiency and the timing properties have been measured. A comparison with the performances of a standard 25% n-type HPGe detector is presented. (orig.).

  12. Performances of large volume p-type HPGe detectors

    International Nuclear Information System (INIS)

    Bellia, G.; Del Zoppo, A.; Migneco, E.; Sapienza, P.

    1989-01-01

    The performances of large volume (about 350 cm 3 and relative efficiency greater than 75%) p-type HPGe detectors are reported. The response function to γ-rays up to 11.67 MeV, the energy dependence of the full energy detection efficiency and the timing properties have been measured. A comparison with the performances of a standard 25% n-type HPGe detector is presented. (orig.)

  13. Volume production of polarization controlled single-mode VCSELs

    Science.gov (United States)

    Grabherr, Martin; King, Roger; Jäger, Roland; Wiedenmann, Dieter; Gerlach, Philipp; Duckeck, Denise; Wimmer, Christian

    2008-02-01

    Over the past 3 years laser based tracking systems for optical PC mice have outnumbered the traditional VCSEL market datacom by far. Whereas VCSEL for datacom in the 850 nm regime emit in multipe transverse modes, all laser based tracking systems demand for single-mode operation which require advanced manufacturing technology. Next generation tracking systems even require single-polarization characteristics in order to avoid unwanted movement of the pointer due to polarization flips. High volume manufacturing and optimized production methods are crucial for achieving the addressed technical and commercial targets of this consumer market. The resulting ideal laser source which emits single-mode and single-polarization at low cost is also a promising platform for further applications like tuneable diode laser absorption spectroscopy (TDLAS) or miniature atomic clocks when adapted to the according wavelengths.

  14. Electrolyte and Haemogram changes post large volume liposuction comparing two different tumescent solutions

    Directory of Open Access Journals (Sweden)

    Kumar Vivek

    2014-01-01

    Full Text Available Background: The most common definitions of large volume liposuction refer to total 5 l volume aspiration during a single procedure (fat plus wetting solution. Profound haemodynamic and metabolic alterations can accompany large volume liposuction. Due to paucity of literature on the effect of different tumescent solutions on the electrolyte balance and haematological changes during large volume liposuction, we carried out this study using two different wetting solutions to study the same. Materials and Methods: Total 30 patients presenting with varying degrees of localized lipodystrophy in different body regions were enrolled for the study. Prospective randomized controlled trial was conducted by Department of Plastic and Cosmetic Surgery, Sir Ganga Ram Hospital, New Delhi from January 2011 to June 2012. Patients were randomized into two groups of 15 patients each by using computer generated random numbers. Tumescent formula used for Group A (normal saline [NS] was our modification of Klein′s Formula and Tumescent formula used for Group B (ringer lactate [RL] was our modification of Hunstadt′s formula. Serum electrolytes and hematocrit levels were done at preinduction, immediate postoperative period and postoperative day 1. Result: Statistical analysis was performed using SPSS software version 15.0. Which showed statistically significant electrolytes and hematocrit changes occur during large volume liposuction. Conclusion: Statistically significant electrolytes and hematocrit changes occur during large volume liposuction and patients should be kept under observation of anaesthesist for at least 24 h. Patients require strict monitoring of vital parameters and usually Intensive Care Unit is not required. There was no statistical difference in the electrolyte changes using NS or RL as tumescent solution and both solutions were found safe for large volume liposuction.

  15. Electrolyte and Haemogram changes post large volume liposuction comparing two different tumescent solutions.

    Science.gov (United States)

    Vivek, Kumar; Amiti, Shah; Shivshankar, Saha; Lalit, Choudhary

    2014-01-01

    The most common definitions of large volume liposuction refer to total 5 l volume aspiration during a single procedure (fat plus wetting solution). Profound haemodynamic and metabolic alterations can accompany large volume liposuction. Due to paucity of literature on the effect of different tumescent solutions on the electrolyte balance and haematological changes during large volume liposuction, we carried out this study using two different wetting solutions to study the same. Total 30 patients presenting with varying degrees of localized lipodystrophy in different body regions were enrolled for the study. Prospective randomized controlled trial was conducted by Department of Plastic and Cosmetic Surgery, Sir Ganga Ram Hospital, New Delhi from January 2011 to June 2012. Patients were randomized into two groups of 15 patients each by using computer generated random numbers. Tumescent formula used for Group A (normal saline [NS]) was our modification of Klein's Formula and Tumescent formula used for Group B (ringer lactate [RL]) was our modification of Hunstadt's formula. Serum electrolytes and hematocrit levels were done at preinduction, immediate postoperative period and postoperative day 1. Statistical analysis was performed using SPSS software version 15.0. Which showed statistically significant electrolytes and hematocrit changes occur during large volume liposuction. Statistically significant electrolytes and hematocrit changes occur during large volume liposuction and patients should be kept under observation of anaesthesist for at least 24 h. Patients require strict monitoring of vital parameters and usually Intensive Care Unit is not required. There was no statistical difference in the electrolyte changes using NS or RL as tumescent solution and both solutions were found safe for large volume liposuction.

  16. Large volume high-pressure cell for inelastic neutron scattering

    International Nuclear Information System (INIS)

    Wang, W.; Kamenev, K. V.; Sokolov, D. A.; Huxley, A. D.

    2011-01-01

    Inelastic neutron scattering measurements typically require two orders of magnitude longer data collection times and larger sample sizes than neutron diffraction studies. Inelastic neutron scattering measurements on pressurised samples are particularly challenging since standard high-pressure apparatus restricts sample volume, attenuates the incident and scattered beams, and contributes background scattering. Here, we present the design of a large volume two-layered piston-cylinder pressure cell with optimised transmission for inelastic neutron scattering experiments. The design and the materials selected for the construction of the cell enable its safe use to a pressure of 1.8 GPa with a sample volume in excess of 400 mm 3 . The design of the piston seal eliminates the need for a sample container, thus providing a larger sample volume and reduced absorption. The integrated electrical plug with a manganin pressure gauge offers an accurate measurement of pressure over the whole range of operational temperatures. The performance of the cell is demonstrated by an inelastic neutron scattering study of UGe 2 .

  17. Large volume high-pressure cell for inelastic neutron scattering.

    Science.gov (United States)

    Wang, W; Sokolov, D A; Huxley, A D; Kamenev, K V

    2011-07-01

    Inelastic neutron scattering measurements typically require two orders of magnitude longer data collection times and larger sample sizes than neutron diffraction studies. Inelastic neutron scattering measurements on pressurised samples are particularly challenging since standard high-pressure apparatus restricts sample volume, attenuates the incident and scattered beams, and contributes background scattering. Here, we present the design of a large volume two-layered piston-cylinder pressure cell with optimised transmission for inelastic neutron scattering experiments. The design and the materials selected for the construction of the cell enable its safe use to a pressure of 1.8 GPa with a sample volume in excess of 400 mm(3). The design of the piston seal eliminates the need for a sample container, thus providing a larger sample volume and reduced absorption. The integrated electrical plug with a manganin pressure gauge offers an accurate measurement of pressure over the whole range of operational temperatures. The performance of the cell is demonstrated by an inelastic neutron scattering study of UGe(2).

  18. The Combination of Tissue Dissection and External Volume Expansion Generates Large Volumes of Adipose Tissue.

    Science.gov (United States)

    He, Yunfan; Dong, Ziqing; Xie, Gan; Zhou, Tao; Lu, Feng

    2017-04-01

    Noninvasive external volume expansion device has been applied to stimulate nonsurgical breast enlargement in clinical settings. Although previous results demonstrate the capacity of external volume expansion to increase the number of adipocytes, this strategy alone is insufficient to reconstruct soft-tissue defects or increase breast mass. The authors combined a minimally invasive tissue dissection method with external volume expansion to generate large volumes of adipose tissue. In vitro, various densities of adipose-derived stem cells were prepared to evaluate relations between cell contacts and cell proliferation. In vivo, dorsal adipose tissue of rabbits was thoroughly dissected and the external volume expansion device was applied to maintain the released state. External volume expansion without tissue dissection served as the control. In the dissection group, the generated adipose tissue volume was much larger than that in the control group at all time points. A larger number of proliferating cells appeared in the dissection samples than in the control samples at the early stage after tissue dissection. At low cell density, adipose-derived stem cells displayed an increasing proliferation rate compared to high cell density. Protein expression analysis revealed that cell proliferation was mediated by a similar mechanism both in vivo and in vitro, involving the release of cell contact inhibition and Hippo/Yes-associated protein pathway activation. Adipose tissue dissection releases cell-to-cell contacts and induces adipose-derived stem cell proliferation. Preexpanded adipose-derived stem cells undergo adipogenesis under the adipogenic environment created by external volume expansion, leading to better adipose regeneration compared with the control.

  19. Light propagation in a large volume liquid scintillator

    Energy Technology Data Exchange (ETDEWEB)

    Alimonti, G.; Arpesella, C.; Balata, M.; Bellini, G.; Benziger, J.; Bonetti, S.; Caccianiga, B.; Cadonati, L.; Calaprice, F.P.; Cecchet, G.; Chen, M.; Darnton, N.; De Bari, A.; Deutsch, M.; Elisei, F.; Feilitzsch, F. von; Galbiati, C.; Gatti, F.; Giammarchi, M.G.; Giugni, D.; Goldbrunner, T.; Golubchikov, A.; Goretti, A.; Hagner, T.; Hartmann, F.X.; Hentig, R. von; Heusser, G.; Ianni, A.; Johnson, M.; Laubenstein, M.; Lombardi, P.; Magni, S.; Malvezzi, S.; Maneira, J.; Manno, I.; Manuzio, G.; Masetti, F.; Mazzucato, U.; Meroni, E.; Neff, M.; Oberauer, L.; Perotti, A.; Raghavan, R.S.; Ranucci, G.; Resconi, E.; Salvo, C.; Scardaoni, R.; Schoenert, S.; Smirnov, O.; Tartaglia, R.; Testera, G. E-mail: testera@ge.infn.it; Vogelaar, R.B.; Vitale, S.; Zaimidoroga, O

    2000-02-01

    The fluorescence light propagation in a large volume detector based on organic liquid scintillators is discussed. In particular, the effects of the fluor radiative transport and solvent Rayleigh scattering are emphasized. These processes have been modelled by a ray-tracing Monte Carlo method and have been experimentally investigated in the Borexino prototype which was a 4.3 ton, 4{pi} sensitive detector. The comparison between the model prediction and the experimental data shows a satisfactory agreement indicating that the main aspects of these processes are well understood. Some features of the experimental time response of the detector are still under study.

  20. Removal of rare gases from large volume airstreams

    International Nuclear Information System (INIS)

    Hopke, P.K.; Leong, K.H.; Stukel, J.J.; Lewis, C.; Jebackumar, R.; Illinois Univ., Urbana; Illinois Univ., Urbana

    1986-01-01

    The cost-effective removal of low levels of rare gases and particularly radon from large volume air flows is a difficult problem. The use of various scrubbing systems using non-conventional fluids has been studied. The parameters for both a packed tower absorber and a gas scrubber have been calculated for a system using perfluorobenzene as the fluid. Based on these parameters, a packed bed tower of conventional proportions is feasible for the removal of >95% of 37 Bq/m 3 of radon from a flow of 4.7 m 3 /second. (author)

  1. Naturally light hidden photons in LARGE volume string compactifications

    Energy Technology Data Exchange (ETDEWEB)

    Goodsell, M. [LPTHE, Univ. Pierre et Marie Curie, Paris (France); Jaeckel, J. [Inst. for Particle Physics Phenomenology, Univ. Durham (United Kingdom); Redondo, J.; Ringwald, A. [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany)

    2009-09-15

    Extra ''hidden'' U(1) gauge factors are a generic feature of string theory that is of particular phenomenological interest. They can kinetically mix with the Standard Model photon and are thereby accessible to a wide variety of astrophysical and cosmological observations and laboratory experiments. In this paper we investigate the masses and the kinetic mixing of hidden U(1)s in LARGE volume compactifications of string theory. We find that in these scenarios the hidden photons can be naturally light and that their kinetic mixing with the ordinary electromagnetic photon can be of a size interesting for near future experiments and observations. (orig.)

  2. Naturally light hidden photons in LARGE volume string compactifications

    International Nuclear Information System (INIS)

    Goodsell, M.; Jaeckel, J.; Redondo, J.; Ringwald, A.

    2009-09-01

    Extra ''hidden'' U(1) gauge factors are a generic feature of string theory that is of particular phenomenological interest. They can kinetically mix with the Standard Model photon and are thereby accessible to a wide variety of astrophysical and cosmological observations and laboratory experiments. In this paper we investigate the masses and the kinetic mixing of hidden U(1)s in LARGE volume compactifications of string theory. We find that in these scenarios the hidden photons can be naturally light and that their kinetic mixing with the ordinary electromagnetic photon can be of a size interesting for near future experiments and observations. (orig.)

  3. Light propagation in a large volume liquid scintillator

    CERN Document Server

    Alimonti, G; Balata, M; Bellini, G; Benziger, J; Bonetti, S; Caccianiga, B; Cadonati, L; Calaprice, F P; Cecchet, G; Chen, M; Darnton, N; De Bari, A; Deutsch, M; Elisei, F; Feilitzsch, F V; Galbiati, C; Gatti, F; Giammarchi, M G; Giugni, D; Goldbrunner, T; Golubchikov, A; Goretti, A; Hagner, T; Hartmann, F X; Hentig, R V; Heusser, G; Ianni, A; Johnson, M; Laubenstein, M; Lombardi, P; Magni, S; Malvezzi, S; Maneira, J; Manno, I; Manuzio, G; Masetti, F; Mazzucato, U; Meroni, E; Neff, M; Oberauer, L; Perotti, A; Raghavan, R S; Ranucci, G; Resconi, E; Salvo, C; Scardaoni, R; Schönert, S; Smirnov, O; Tartaglia, R; Testera, G; Vogelaar, R B; Vitale, S; Zaimidoroga, O A

    2000-01-01

    The fluorescence light propagation in a large volume detector based on organic liquid scintillators is discussed. In particular, the effects of the fluor radiative transport and solvent Rayleigh scattering are emphasized. These processes have been modelled by a ray-tracing Monte Carlo method and have been experimentally investigated in the Borexino prototype which was a 4.3 ton, 4 pi sensitive detector. The comparison between the model prediction and the experimental data shows a satisfactory agreement indicating that the main aspects of these processes are well understood. Some features of the experimental time response of the detector are still under study.

  4. Prospects for the synthesis of large single-crystal diamonds

    International Nuclear Information System (INIS)

    Khmelnitskiy, R A

    2015-01-01

    The unique properties of diamond have stimulated the study of and search for its applications in many fields, including optics, optoelectronics, electronics, biology, and electrochemistry. Whereas chemical vapor deposition allows the growth of polycrystalline diamond plates more than 200 mm in diameter, most current diamond application technologies require large-size (25 mm and more) single-crystal diamond substrates or films suitable for the photolithography process. This is quite a challenge, because the largest diamond crystals currently available are 10 mm or less in size. This review examines three promising approaches to fabricating large-size diamond single crystals: growing large-size single crystals, the deposition of heteroepitaxial diamond films on single-crystal substrates, and the preparation of composite diamond substrates. (reviews of topical problems)

  5. Stability of dobutamine hydrochloride in selected large-volume parenterals.

    Science.gov (United States)

    Kirschenbaum, H L; Aronoff, W; Perentesis, G P; Piltz, G W; Goldberg, R J; Cutie, A J

    1982-11-01

    Stability of dobutamine hydrochloride when mixed with large-volume parenteral solutions was assessed. Dobutamine hydrochloride was added to large-volume solutions of 5% dextrose injection, 0.9% sodium chloride injection, lactated Ringer's injection, and 5% dextrose and 0.45% sodium chloride injection, in both glass and polyvinyl chloride containers; the initial concentration was 1 mg/ml. After 0.25, 1, 3, 8, 24, and 48 hours, the concentration of dobutamine hydrochloride was determined by high-pressure liquid chromatography assay, and each solution was visually examined for evidence of haze, precipitation, color change, or evolution of gas. Concentration of dobutamine hydrochloride in the samples did not exhibit any appreciable change over the 48-hour period, and no HPLC peaks indicating degradation products were noted. Color changes were observed in some of the solutions, but no other visual changes occurred. There were no apparent differences in stability between the admixtures packaged in glass and those in polyvinyl chloride bags. At the concentration studied, dobutamine hydrochloride is stable in the admixtures tested for a minimum of 48 hours.

  6. Effect of large volume paracentesis on plasma volume--a cause of hypovolemia

    International Nuclear Information System (INIS)

    Kao, H.W.; Rakov, N.E.; Savage, E.; Reynolds, T.B.

    1985-01-01

    Large volume paracentesis, while effectively relieving symptoms in patients with tense ascites, has been generally avoided due to reports of complications attributed to an acute reduction in intravascular volume. Measurements of plasma volume in these subjects have been by indirect methods and have not uniformly confirmed hypovolemia. We have prospectively evaluated 18 patients (20 paracenteses) with tense ascites and peripheral edema due to chronic liver disease undergoing 5 liter paracentesis for relief of symptoms. Plasma volume pre- and postparacentesis was assessed by a 125 I-labeled human serum albumin dilution technique as well as by the change in hematocrit and postural blood pressure difference. No significant change in serum sodium, urea nitrogen, hematocrit or postural systolic blood pressure difference was noted at 24 or 48 hr after paracentesis. Serum creatinine at 24 hr after paracentesis was unchanged but a small but statistically significant increase in serum creatinine was noted at 48 hr postparacentesis. Plasma volume changed -2.7% (n = 6, not statistically significant) during the first 24 hr and -2.8% (n = 12, not statistically significant) during the 0- to 48-hr period. No complications from paracentesis were noted. These results suggest that 5 liter paracentesis for relief of symptoms is safe in patients with tense ascites and peripheral edema from chronic liver disease

  7. Ultra-large single crystals by abnormal grain growth.

    Science.gov (United States)

    Kusama, Tomoe; Omori, Toshihiro; Saito, Takashi; Kise, Sumio; Tanaka, Toyonobu; Araki, Yoshikazu; Kainuma, Ryosuke

    2017-08-25

    Producing a single crystal is expensive because of low mass productivity. Therefore, many metallic materials are being used in polycrystalline form, even though material properties are superior in a single crystal. Here we show that an extraordinarily large Cu-Al-Mn single crystal can be obtained by abnormal grain growth (AGG) induced by simple heat treatment with high mass productivity. In AGG, the sub-boundary energy introduced by cyclic heat treatment (CHT) is dominant in the driving pressure, and the grain boundary migration rate is accelerated by repeating the low-temperature CHT due to the increase of the sub-boundary energy. With such treatment, fabrication of single crystal bars 70 cm in length is achieved. This result ensures that the range of applications of shape memory alloys will spread beyond small-sized devices to large-scale components and may enable new applications of single crystals in other metallic and ceramics materials having similar microstructural features.Growing large single crystals cheaply and reliably for structural applications remains challenging. Here, the authors combine accelerated abnormal grain growth and cyclic heat treatments to grow a superelastic shape memory alloy single crystal to 70 cm.

  8. Large Volume Coagulation Utilizing Multiple Cavitation Clouds Generated by Array Transducer Driven by 32 Channel Drive Circuits

    Science.gov (United States)

    Nakamura, Kotaro; Asai, Ayumu; Sasaki, Hiroshi; Yoshizawa, Shin; Umemura, Shin-ichiro

    2013-07-01

    High-intensity focused ultrasound (HIFU) treatment is a noninvasive treatment, in which focused ultrasound is generated outside the body and coagulates a diseased tissue. The advantage of this method is minimal physical and mental stress to the patient, and the disadvantage is the long treatment time caused by the smallness of the therapeutic volume by a single exposure. To improve the efficiency and shorten the treatment time, we are focusing attention on utilizing cavitation bubbles. The generated microbubbles can convert the acoustic energy into heat with a high efficiency. In this study, using the class D amplifiers, which we have developed, to drive the array transducer, we demonstrate a new method to coagulate a large volume by a single HIFU exposure through generating cavitation bubbles distributing in a large volume and vibrating all of them. As a result, the coagulated volume by the proposed method was 1.71 times as large as that of the conventional method.

  9. Large volume water sprays for dispersing warm fogs

    Science.gov (United States)

    Keller, V. W.; Anderson, B. J.; Burns, R. A.; Lala, G. G.; Meyer, M. B.

    1986-01-01

    A new method for dispersing of warm fogs which impede visibility and alter schedules is described. The method uses large volume recycled water sprays to create curtains of falling drops through which the fog is processed by the ambient wind and spray-induced air flow; the fog droplets are removed by coalescence/rainout. The efficiency of this fog droplet removal process depends on the size spectra of the spray drops and optimum spray drop size is calculated as between 0.3-1.0 mm in diameter. Water spray tests were conducted in order to determine the drop size spectra and temperature response of sprays produced by commercially available fire-fighting nozzles, and nozzle array tests were utilized to study air flow patterns and the thermal properties of the overall system. The initial test data reveal that the fog-dispersal procedure is effective.

  10. Volume visualization of multiple alignment of large genomicDNA

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Nameeta; Dillard, Scott E.; Weber, Gunther H.; Hamann, Bernd

    2005-07-25

    Genomes of hundreds of species have been sequenced to date, and many more are being sequenced. As more and more sequence data sets become available, and as the challenge of comparing these massive ''billion basepair DNA sequences'' becomes substantial, so does the need for more powerful tools supporting the exploration of these data sets. Similarity score data used to compare aligned DNA sequences is inherently one-dimensional. One-dimensional (1D) representations of these data sets do not effectively utilize screen real estate. As a result, tools using 1D representations are incapable of providing informatory overview for extremely large data sets. We present a technique to arrange 1D data in 3D space to allow us to apply state-of-the-art interactive volume visualization techniques for data exploration. We demonstrate our technique using multi-millions-basepair-long aligned DNA sequence data and compare it with traditional 1D line plots. The results show that our technique is superior in providing an overview of entire data sets. Our technique, coupled with 1D line plots, results in effective multi-resolution visualization of very large aligned sequence data sets.

  11. Automated single particle detection and tracking for large microscopy datasets.

    Science.gov (United States)

    Wilson, Rhodri S; Yang, Lei; Dun, Alison; Smyth, Annya M; Duncan, Rory R; Rickman, Colin; Lu, Weiping

    2016-05-01

    Recent advances in optical microscopy have enabled the acquisition of very large datasets from living cells with unprecedented spatial and temporal resolutions. Our ability to process these datasets now plays an essential role in order to understand many biological processes. In this paper, we present an automated particle detection algorithm capable of operating in low signal-to-noise fluorescence microscopy environments and handling large datasets. When combined with our particle linking framework, it can provide hitherto intractable quantitative measurements describing the dynamics of large cohorts of cellular components from organelles to single molecules. We begin with validating the performance of our method on synthetic image data, and then extend the validation to include experiment images with ground truth. Finally, we apply the algorithm to two single-particle-tracking photo-activated localization microscopy biological datasets, acquired from living primary cells with very high temporal rates. Our analysis of the dynamics of very large cohorts of 10 000 s of membrane-associated protein molecules show that they behave as if caged in nanodomains. We show that the robustness and efficiency of our method provides a tool for the examination of single-molecule behaviour with unprecedented spatial detail and high acquisition rates.

  12. A large volume flat coil probe for oriented membrane proteins

    Science.gov (United States)

    Gor'kov, Peter L.; Chekmenev, Eduard Y.; Fu, Riqiang; Hu, Jun; Cross, Timothy A.; Cotten, Myriam; Brey, William W.

    2006-07-01

    15N detection of mechanically aligned membrane proteins benefits from large sample volumes that compensate for the low sensitivity of the observe nuclei, dilute sample preparation, and for the poor filling factor arising from the presence of alignment plates. Use of larger multi-tuned solenoids, however, is limited by wavelength effects that lead to inhomogeneous RF fields across the sample, complicating cross-polarization experiments. We describe a 600 MHz 15N-1H solid-state NMR probe with large (580 mm3) RF solenoid for high-power, multi-pulse sequence experiments, such as polarization inversion spin exchange at the magic angle (PISEMA). In order to provide efficient detection for 15N, a 4-turn solenoidal sample coil is used that exceeds 0.27λ at the 600 MHz 1H resonance. A balanced tuning-matching circuit is employed to preserve RF homogeneity across the sample for adequate magnetization transfer from 1H to 15N. We describe a procedure for optimization of the shorted 1/4λ coaxial trap that allows for the sufficiently strong RF fields in both 1H and 15N channels to be achieved within the power limits of 300 W 1H and 1 kW 15N amplifiers. The 8 × 6 × 12 mm solenoid sustains simultaneous B1 irradiation of 100 kHz at 1H frequency and 51 kHz at 15N frequency for at least 5 ms with 265 and 700 W of input power in the respective channels. The probe functionality is demonstrated by 2D 15N-1H PISEMA spectroscopy for two applications at 600 MHz.

  13. Testing large volume water treatment and crude oil ...

    Science.gov (United States)

    Report EPA’s Homeland Security Research Program (HSRP) partnered with the Idaho National Laboratory (INL) to build the Water Security Test Bed (WSTB) at the INL test site outside of Idaho Falls, Idaho. The WSTB was built using an 8-inch (20 cm) diameter cement-mortar lined drinking water pipe that was previously taken out of service. The pipe was exhumed from the INL grounds and oriented in the shape of a small drinking water distribution system. Effluent from the pipe is captured in a lagoon. The WSTB can support drinking water distribution system research on a variety of drinking water treatment topics including biofilms, water quality, sensors, and homeland security related contaminants. Because the WSTB is constructed of real drinking water distribution system pipes, research can be conducted under conditions similar to those in a real drinking water system. In 2014, WSTB pipe was experimentally contaminated with Bacillus globigii spores, a non-pathogenic surrogate for the pathogenic B. anthracis, and then decontaminated using chlorine dioxide. In 2015, the WSTB was used to perform the following experiments: • Four mobile disinfection technologies were tested for their ability to disinfect large volumes of biologically contaminated “dirty” water from the WSTB. B. globigii spores acted as the biological contaminant. The four technologies evaluated included: (1) Hayward Saline C™ 6.0 Chlorination System, (2) Advanced Oxidation Process (A

  14. Mass anomalous dimension of adjoint QCD at large N from twisted volume reduction

    Energy Technology Data Exchange (ETDEWEB)

    Pérez, Margarita García [Instituto de Física Teórica UAM-CSIC, Nicolás Cabrera 13-15, Universidad Autónoma de Madrid,E-28049-Madrid (Spain); González-Arroyo, Antonio [Instituto de Física Teórica UAM-CSIC, Nicolás Cabrera 13-15, Universidad Autónoma de Madrid,E-28049-Madrid (Spain); Departamento de Física Teórica, C-XI, Universidad Autónoma de Madrid,E-28049-Madrid (Spain); Keegan, Liam [PH-TH, CERN,CH-1211 Geneva 23 (Switzerland); Okawa, Masanori [Graduate School of Science, Hiroshima University,Higashi-Hiroshima, Hiroshima 739-8526 (Japan); Core of Research for the Energetic Universe, Hiroshima University,Higashi-Hiroshima, Hiroshima 739-8526 (Japan)

    2015-08-07

    In this work we consider the SU(N) gauge theory with two Dirac fermions in the adjoint representation, in the limit of large N. In this limit the infinite-volume physics of this model can be studied by means of the corresponding twisted reduced model defined on a single site lattice. Making use of this strategy we study the reduced model for various values of N up to 289. By analyzing the eigenvalue distribution of the adjoint Dirac operator we test the conformality of the theory and extract the corresponding mass anomalous dimension.

  15. Mass anomalous dimension of Adjoint QCD at large N from twisted volume reduction

    CERN Document Server

    Pérez, Margarita García; Keegan, Liam; Okawa, Masanori

    2015-01-01

    In this work we consider the $SU(N)$ gauge theory with two Dirac fermions in the adjoint representation, in the limit of large $N$. In this limit the infinite-volume physics of this model can be studied by means of the corresponding twisted reduced model defined on a single site lattice. Making use of this strategy we study the reduced model for various values of $N$ up to 289. By analyzing the eigenvalue distribution of the adjoint Dirac operator we test the conformality of the theory and extract the corresponding mass anomalous dimension.

  16. Research status of large mode area single polarization active fiber

    Science.gov (United States)

    Xiao, Chun; Zhang, Ge; Yang, Bin-hua; Cheng, Wei-feng; Gu, Shao-yi

    2018-03-01

    As high power fiber laser used more and more widely, to increase the output power of fiber laser and beam quality improvement have become an important goal for the development of high power fiber lasers. The use of large mode fiber is the most direct and effective way to solve the nonlinear effect and fiber damage in the fiber laser power lifting process. In order to reduce the effect of polarization of the fiber laser system, the study found that when introduces a birefringence in the single-mode fiber, the polarization state changes caused by the birefringence is far greater than the random polarization state changes, then the external disturbance is completely submerged, finally the polarization can be controlled and stabilized. Through the fine design of the fiber structure, if the birefringence is high enough to achieve the separation of the two polarization states, the fiber will have a different cut-off mechanism to eliminate polarization which is not need, which will realize single mode single polarization transmission in a band. In this paper, different types of single polarization fiber design are presented and the application of these fibers are also discussed.

  17. Numerical simulation of seismic wave propagation from land-excited large volume air-gun source

    Science.gov (United States)

    Cao, W.; Zhang, W.

    2017-12-01

    The land-excited large volume air-gun source can be used to study regional underground structures and to detect temporal velocity changes. The air-gun source is characterized by rich low frequency energy (from bubble oscillation, 2-8Hz) and high repeatability. It can be excited in rivers, reservoirs or man-made pool. Numerical simulation of the seismic wave propagation from the air-gun source helps to understand the energy partitioning and characteristics of the waveform records at stations. However, the effective energy recorded at a distance station is from the process of bubble oscillation, which can not be approximated by a single point source. We propose a method to simulate the seismic wave propagation from the land-excited large volume air-gun source by finite difference method. The process can be divided into three parts: bubble oscillation and source coupling, solid-fluid coupling and the propagation in the solid medium. For the first part, the wavelet of the bubble oscillation can be simulated by bubble model. We use wave injection method combining the bubble wavelet with elastic wave equation to achieve the source coupling. Then, the solid-fluid boundary condition is implemented along the water bottom. And the last part is the seismic wave propagation in the solid medium, which can be readily implemented by the finite difference method. Our method can get accuracy waveform of land-excited large volume air-gun source. Based on the above forward modeling technology, we analysis the effect of the excited P wave and the energy of converted S wave due to different water shapes. We study two land-excited large volume air-gun fields, one is Binchuan in Yunnan, and the other is Hutubi in Xinjiang. The station in Binchuan, Yunnan is located in a large irregular reservoir, the waveform records have a clear S wave. Nevertheless, the station in Hutubi, Xinjiang is located in a small man-made pool, the waveform records have very weak S wave. Better understanding of

  18. Resonant RF network antennas for large-area and large-volume inductively coupled plasma sources

    International Nuclear Information System (INIS)

    Hollenstein, Ch; Howling, A A; Guittienne, Ph

    2013-01-01

    Large-area and large-volume radio frequency (RF) plasmas are produced by different arrangements of an elementary electrical mesh consisting of two conductors interconnected by a capacitor at each end. The obtained cylindrical and planar RF networks are resonant and generate very high RF currents. The input impedance of such RF networks shows the behaviour of an RLC parallel resonance equivalent circuit. The real impedance at the resonance frequency is of great advantage for power matching compared with conventional inductive devices. Changes in the RLC equivalent circuit during the observed E–H transition will allow future interpretation of the plasma–antenna coupling. Furthermore, high power transfer efficiencies are found during inductively coupled plasma (ICP) operation. For the planar RF antenna network it is shown that the E–H transition occurs simultaneously over the entire antenna. The underlying physics of these discharges induced by the resonant RF network antenna is found to be identical to that of the conventional ICP devices described in the literature. The resonant RF network antenna is a new versatile plasma source, which can be adapted to applications in industry and research. (paper)

  19. Imaging large cohorts of single ion channels and their activity

    Directory of Open Access Journals (Sweden)

    Katia eHiersemenzel

    2013-09-01

    Full Text Available As calcium is the most important signaling molecule in neurons and secretory cells, amongst many other cell types, it follows that an understanding of calcium channels and their regulation of exocytosis is of vital importance. Calcium imaging using calcium dyes such as Fluo3, or FRET-based dyes that have been used widely has provided invaluable information, which combined with modeling has estimated the sub-types of channels responsible for triggering the exocytotic machinery as well as inferences about the relative distances away from vesicle fusion sites these molecules adopt. Importantly, new super-resolution microscopy techniques, combined with novel Ca2+ indicators and imaginative imaging approaches can now define directly the nanoscale locations of very large cohorts of single channel molecules in relation to single vesicles. With combinations of these techniques the activity of individual channels can be visualized and quantified using novel Ca2+ indicators. Fluorescently labeled specific channel toxins can also be used to localize endogenous assembled channel tetramers. Fluorescence lifetime imaging microscopy and other single-photon-resolution spectroscopic approaches offer the possibility to quantify protein-protein interactions between populations of channels and the SNARE protein machinery for the first time. Together with simultaneous electrophysiology, this battery of quantitative imaging techniques has the potential to provide unprecedented detail describing the locations, dynamic behaviours, interactions and conductance activities of many thousands of channel molecules and vesicles in living cells.

  20. Ideas for future large single dish radio telescopes

    Science.gov (United States)

    Kärcher, Hans J.; Baars, Jacob W. M.

    2014-07-01

    The existing large single dish radio telescopes of the 100m class (Effelsberg, Green Bank) were built in the 1970s and 1990s. With some active optics they work now down to 3 millimeter wavelength where the atmospheric quality of the site is also a limiting factor. Other smaller single dish telescopes (50m LMT Mexico, 30m IRAM Spain) are located higher and reach sub-millimeter quality, and the much smaller 12m antennas of the ALMA array reach at a very high site the Terahertz region. They use advanced technologies as carbon fiber structures and flexible body control. We review natural limits to telescope design and use the examples of a number of telescopes for an overview of the available state-of-the-art in design, engineering and technologies. Without considering the scientific justification we then offer suggestions to realize ultimate performance of huge single dish telescopes (up to 160m). We provide an outlook on design options, technological frontiers and cost estimates.

  1. Single sided tomography of extremely large dense objects

    Energy Technology Data Exchange (ETDEWEB)

    Thoe, R.S.

    1993-03-24

    One can envision many circumstances where radiography could be valuable but is frustrated by the geometry of the object to be radiographed. For example, extremely large objects, the separation of rocket propellants from the skin of solid fuel rocket motor, the structural integrity of an underground tank or hull of a ship, the location of buried objects, inspection of large castings etc. The author has been investigating ways to do this type of radiography and as a result has developed a technique which can be used to obtain three dimensional radiographs using Compton scattered radiation from a monochromatic source and a high efficiency, high resolution germanium spectrometer. This paper gives specific details of the reconstruction technique and presents the results of numerous numerical simulations and compares these simulations to spectra obtained in the laboratory. In addition the author presents the results of calculations made for the development of an alternative single sided radiography technique which will permit inspection of the interior of large objects. As a benchmark the author seeks to obtain three dimensional images with a resolution of about one cubic centimeter in a concrete cube 30 centimeters on a side. Such a device must use photons of very high energy. For example 30 cm of concrete represents about 15 mean free paths for photons of 100 keV, whereas at 1 MeV the attenuation is down to about five mean free paths. At these higher energies Compton scattering becomes much more probable. Although this would appear to be advantageous for single sided imaging techniques, such techniques are hampered by two side effects. In this paper the results are given of numerous Monte Carlo calculations detailing the extent of the multiple scattering and the feasibility of a variety of imaging schemes is explored.

  2. Large-volume on-column injections for gas chromatography.

    NARCIS (Netherlands)

    Ramalho, S.; Hankemeier, T.; de Jong, M.; Brinkman, U.A.T.; Vreuls, J.J.

    1996-01-01

    Large‐volume injection is an attractive means to improve detection limits when analyzing dilute sample extracts. There is now no need to achieve enrichment by means of solvent evaporation, which makes the total analytical procedure less reliable and less robust due to loss of volatile compounds. In

  3. Hematological changes after single large dose half-body irradiation

    International Nuclear Information System (INIS)

    Herrmann, T.; Friedrich, S.; Jochem, I.; Eberhardt, H.J.; Koch, R.; Knorr, A.

    1981-01-01

    The determination of different peripheral blood parameters aimed at the study of side effects on the hematological cellular system following a 5 - 8 Gy single large dose half-body irradiation in 20 patients. Compared to the initial values the leukocytes between the 6. and 14., the thrombocytes between the 14. and 21. postirradiation day as well as the lymphocytes between 3 hours and 4 weeks postirradiation were significantly decreased without exhibiting complications such as hemorrhages or infections. The hemoglobin, hematocrit and reticulocyte values revealed but a slight decrease normalized within a 28 days postirradiation period. Transfusions were necessary when a tumor-caused anemia was present prior to irradiation. Changes in serum activity of aminotransferases and lactate dehydrogenase occured during the first hours after irradiation and were due to enzyme release from destroyed tumor cells

  4. Sensitivity of the amplitude of the single muscle fibre action potential to microscopic volume conduction parameters

    NARCIS (Netherlands)

    Alberts, B.A.; Rutten, Wim; Wallinga, W.; Boom, H.B.K.

    1988-01-01

    A microscopic model of volume conduction was applied to examine the sensitivity of the single muscle fibre action potential to variations in parameters of the source and of the volume conductor, such as conduction velocity, intracellular conductivity and intracellular volume fraction. The model

  5. Real-time alpha emitter assay of large volumes

    International Nuclear Information System (INIS)

    Kerr, P.L.; Koster, J.E.; Macy, K.; Cook, J.

    1997-01-01

    In this paper we discuss the design and behavior of a High Airflow Monitor (HAFM) based on Long-Range Alpha Detector (LRAD) technology [1]. The low air resistance construction of the HAFM enables the high airflow crucial for assay of rooms, vaults, or cargo vehicles. This is accomplished by orienting plates parallel to the airflow rather than perpendicular, as are the grids in other LRADS. As will be shown in this paper, the advantages of an LRAD-based volume monitor are its inexpensive simplicity, ruggedness, and its ability to detect contamination that is hidden from traditional alpha detection methods such as Geiger-Muller, gas cell, or solid-state detectors

  6. Volume changes of extremely large and giant intracranial aneurysms after treatment with flow diverter stents

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Angelo; Byrne, James V. [ohn Radcliffe Hospital, Oxford Neurovascular and Neuroradiology Research Unit, Nuffield Department of Surgical Sciences, Oxford (United Kingdom); Rane, Neil; Kueker, Wilhelm; Cellerini, Martino; Corkill, Rufus [John Radcliffe Hospital, Department of Neuroradiology, Oxford (United Kingdom)

    2014-01-15

    This study assessed volume changes of unruptured large and giant aneurysms (greatest diameter >20 mm) after treatment with flow diverter (FD) stents. Clinical audit of the cases treated in a single institution, over a 5-year period. Demographic and clinical data were retrospectively collected from the hospital records. Aneurysm volumes were measured by manual outlining at sequential slices using computerised tomography (CT) or magnetic resonance (MR) angiography data. The audit included eight patients (seven females) with eight aneurysms. Four aneurysms involved the cavernous segment of the internal carotid artery (ICA), three the supraclinoid ICA and one the basilar artery. Seven patients presented with signs and symptoms of mass effect and one with seizures. All but one aneurysm was treated with a single FD stent; six aneurysms were also coiled (either before or simultaneously with FD placement). Minimum follow-up time was 6 months (mean 20 months). At follow-up, three aneurysms decreased in size, three were unchanged and two increased. Both aneurysms that increased in size showed persistent endosaccular flow at follow-up MR; in one case, failure was attributed to suboptimal position of the stent; in the other case, it was attributed to persistence of a side branch originating from the aneurysm (similar to the endoleak phenomenon of aortic aneurysms). At follow-up, five aneurysms were completely occluded; none of these increased in volume. Complete occlusion of the aneurysms leads, in most cases, to its shrinkage. In cases of late aneurysm growth or regrowth, consideration should be given to possible endoleak as the cause. (orig.)

  7. Multi-hadron spectroscopy in a large physical volume

    DEFF Research Database (Denmark)

    Bulava, John; Hörz, Ben; Morningstar, Colin

    2018-01-01

    We demonstrate the effcacy of the stochastic LapH method to treat all-toall quark propagation on a Nf = 2 + 1 CLS ensemble with large linear spatial extent L = 5:5 fm, allowing us to obtain the benchmark elastic isovector p-wave pion-pion scattering amplitude to good precision already on a relati...

  8. RADON DIAGNOSTIC MEASUREMENT GUIDANCE FOR LARGE BUILDINGS - VOLUME 2. APPENDICES

    Science.gov (United States)

    The report discusses the development of radon diagnostic procedures and mitigation strategies applicable to a variety of large non-residential buildings commonly found in Florida. The investigations document and evaluate the nature of radon occurrence and entry mechanisms for rad...

  9. Single-pass multi-view volume rendering

    OpenAIRE

    Hübner, T; Pajarola, R

    2007-01-01

    In this paper, we introduce a new direct volume rendering (DVR) algorithm for multi-view auto-stereoscopic displays. Common multi-view methods perform multi-pass rendering (one pass for each view) and subsequent image compositing and masking for generating multiple views. The rendering time increases therefore linearly with the number of views, but sufficient frame-rates are achieved by sub-resolution rendering, at the expense of degraded image quality. To overcome these disadvantages for DVR...

  10. Aircraft Noise Assessment—From Single Components to Large Scenarios

    Directory of Open Access Journals (Sweden)

    Jan Delfs

    2018-02-01

    Full Text Available The strategic European paper “Flightpath 2050” claims dramatic reductions of noise for aviation transport scenarios in 2050: “...The perceived noise emission of flying aircraft is reduced by 65%. These are relative to the capabilities of typical new aircraft in 2000...”. There is a consensus among experts that these far reaching objectives cannot be accomplished by application of noise reduction technologies at the level of aircraft components only. Comparably drastic claims simultaneously expressed in Flightpath 2050 for carbon dioxide and NOX reduction underline the need for step changes in aircraft technologies and aircraft configurations. New aircraft concepts with entirely different propulsion concepts will emerge, including unconventional power supplies from renewable energy sources, ranging from electric over hybrid to synthetic fuels. Given this foreseen revolution in aircraft technology the question arises, how the noise impact of these new aircraft may be assessed. Within the present contribution, a multi-level, multi-fidelity approach is proposed which enables aircraft noise assessment. It is composed by coupling noise prediction methods at three different levels of detail. On the first level, high fidelity methods for predicting the aeroacoustic behavior of aircraft components (and installations are required since in the early stages of the development of innovative noise reduction technology test data is not available. The results are transferred to the second level, where radiation patterns of entire conventional and future aircraft concepts are assembled and noise emissions for single aircraft are computed. In the third level, large scale scenarios with many aircraft are considered to accurately predict the noise exposure for receivers on the ground. It is shown that reasonable predictions of the ground noise exposure level may be obtained. Furthermore, even though simplifications and omissions are introduced, it is shown

  11. GPU-based real-time generation of large ultrasound volumes from freehand 3D sweeps

    Directory of Open Access Journals (Sweden)

    Jauer Philipp

    2015-09-01

    Full Text Available In the recent past, 3D ultrasound has been gaining relevance in many biomedical applications. One main limitation, however, is that typical ultrasound volumes are either very poorly resolved or only cover small areas. We have developed a GPU-accelerated method for live fusion of freehand 3D ultrasound sweeps to create one large volume. The method has been implemented in CUDA and is capable of generating an output volume with 0.5 mm resolution in real time while processing more than 45 volumes per second, with more than 300.000 voxels per volume. First experiments indicate that large structures like a whole forearm or high-resolution volumes of smaller structures like the hand can be combined efficiently. It is anticipated that this technology will be helpful in pediatric surgery where X-ray or CT imaging is not always possible.

  12. Inspection using high resolution holography of large volumes

    International Nuclear Information System (INIS)

    Tozer, B.A.; Webster, J.M.

    With a potential information storage density of 10 16 bits/m 2 , the ability to reconstruct in 3 dimensions, extremely wide angle of view, and potentially diffraction limited resolution, holography should be invaluable for the optical inspection and recording of normally inaccessible regions of nuclear power stations. This paper describes some possible applications and reviews a variety of practical problems which must be overcome if the potential is to be realised. Microscopic analysis of reconstructed real images of whole structures, recorded on a single photographic plate can be carried out at leisure to reveal cracks not visible to the naked eye on the original subject. Holograms of AGR fuel elements show a depth of field greater than the length of the element, with a resolution of about 10 μm at the nearest point and better than 300 μm on the rear grid being obtainable from one hologram. Factors limiting resolution, quality and reliability of holograms are discussed and some results presented which indicate the present boundaries of practical achievement in this promising field. (author)

  13. Large-volume protein crystal growth for neutron macromolecular crystallography.

    Science.gov (United States)

    Ng, Joseph D; Baird, James K; Coates, Leighton; Garcia-Ruiz, Juan M; Hodge, Teresa A; Huang, Sijay

    2015-04-01

    Neutron macromolecular crystallography (NMC) is the prevailing method for the accurate determination of the positions of H atoms in macromolecules. As neutron sources are becoming more available to general users, finding means to optimize the growth of protein crystals to sizes suitable for NMC is extremely important. Historically, much has been learned about growing crystals for X-ray diffraction. However, owing to new-generation synchrotron X-ray facilities and sensitive detectors, protein crystal sizes as small as in the nano-range have become adequate for structure determination, lessening the necessity to grow large crystals. Here, some of the approaches, techniques and considerations for the growth of crystals to significant dimensions that are now relevant to NMC are revisited. These include experimental strategies utilizing solubility diagrams, ripening effects, classical crystallization techniques, microgravity and theoretical considerations.

  14. Large negative differential conductance in single-molecule break junctions

    NARCIS (Netherlands)

    Perrin, Mickael L.; Frisenda, Riccardo; Koole, Max; Seldenthuis, Johannes S.; Gil, Jose A. Celis; Valkenier, Hennie; Hummelen, Jan C.; Renaud, Nicolas; Grozema, Ferdinand C.; Thijssen, Joseph M.; Dulic, Diana; van der Zant, Herre S. J.

    2014-01-01

    Molecular electronics aims at exploiting the internal structure and electronic orbitals of molecules to construct functional building blocks(1). To date, however, the overwhelming majority of experimentally realized single-molecule junctions can be described as single quantum dots, where transport

  15. Local progression and pseudo progression after single fraction or fractionated stereotactic radiotherapy for large brain metastases. A single centre study

    Energy Technology Data Exchange (ETDEWEB)

    Wiggenraad, R.; Verbeek-de Kanter, A.; Mast, M. [Radiotherapy Centre West, The Hague (Netherlands); Molenaar, R. [Diaconessenhuis, Leiden (Netherlands). Dept. of Neurology; Lycklama a Nijeholt, G. [Medical Centre Haagladen, The Hague (Netherlands). Dept. of Radiology; Vecht, C. [Medical Centre Haagladen, The Hague (Netherlands). Dept. of Neurology; Struikmans, H. [Radiotherapy Centre West, The Hague (Netherlands); Leiden Univ. Medical Centre (Netherlands). Dept. of Radiotherapy; Kal, H.B.

    2012-08-15

    Purpose: The 1-year local control rates after single-fraction stereotactic radiotherapy (SRT) for brain metastases > 3 cm diameter are less than 70%, but with fractionated SRT (FSRT) higher local control rates have been reported. The purpose of this study was to compare our treatment results with SRT and FSRT for large brain metastases. Materials and methods: In two consecutive periods, 41 patients with 46 brain metastases received SRT with 1 fraction of 15 Gy, while 51 patients with 65 brain metastases received FSRT with 3 fractions of 8 Gy. We included patients with brain metastases with a planning target volume of > 13 cm{sup 3} or metastases in the brainstem. Results: The minimum follow-up of patients still alive was 22 months. Comparing 1 fraction of 15 Gy with 3 fractions of 8 Gy, the 1-year rates of freedom from any local progression (54% and 61%, p = 0.93) and pseudo progression (85% and 75%, p = 0.25) were not significantly different. Overall survival rates were also not different. Conclusion: The 1-year local progression and pseudo progression rates after 1 fraction of 15 Gy or 3 fractions of 8 Gy for large brain metastases and metastases in the brainstem are similar. For better local control rates, FSRT schemes with a higher biological equivalent dose may be necessary. (orig.)

  16. Single Photon Avalanche Diodes: Towards the Large Bidimensional Arrays

    Directory of Open Access Journals (Sweden)

    Emilio Sciacca

    2008-08-01

    Full Text Available Single photon detection is one of the most challenging goals of photonics. In recent years, the study of ultra-fast and/or low-intensity phenomena has received renewed attention from the academic and industrial communities. Intense research activity has been focused on bio-imaging applications, bio-luminescence, bio-scattering methods, and, more in general, on several applications requiring high speed operation and high timing resolution. In this paper we present design and characterization of bi-dimensional arrays of a next generation of single photon avalanche diodes (SPADs. Single photon sensitivity, dark noise, afterpulsing and timing resolution of the single SPAD have been examined in several experimental conditions. Moreover, the effects arising from their integration and the readout mode have also been deeply investigated.

  17. Single SQUID frequency-domain multiplexer for large bolometer arrays

    International Nuclear Information System (INIS)

    Yoon, Jongsoo; Clarke, John; Gildemeister, J.M.; Lee, Adrian T.; Myers, M.J.; Skidmore, J.T.; Richards, P.L.; Spieler, H.G.

    2001-01-01

    We describe the development of a frequency-domain superconducting quantum interference device (SQUID) multiplexer which monitors a row of low-temperature sensors simultaneously with a single SQUID. Each sensor is ac biased with a unique frequency and all the sensor currents are added in a superconducting summing loop. A single SQUID measures the current in the summing loop, and the individual signals are lock-in detected after the room temperature SQUID electronics. The current in the summing loop is nulled by feedback to eliminate direct crosstalk. We have built an eight-channel prototype and demonstrated channel separation and signal recovery

  18. Single Incision Laparoscopic Surgery for a Large Endometriotic Cyst

    African Journals Online (AJOL)

    In the last decade, laparoscopy has become the standard treatment for many gynecological conditions.[1,2] Today, laparoscopy is hailed as the standard approach in the surgical treatment of benign adnexal pathology.[1,2] Attempts to minimize access-related injuries and complications resulted in development of single port ...

  19. Center-stabilized Yang-Mills theory: Confinement and large N volume independence

    International Nuclear Information System (INIS)

    Uensal, Mithat; Yaffe, Laurence G.

    2008-01-01

    We examine a double trace deformation of SU(N) Yang-Mills theory which, for large N and large volume, is equivalent to unmodified Yang-Mills theory up to O(1/N 2 ) corrections. In contrast to the unmodified theory, large N volume independence is valid in the deformed theory down to arbitrarily small volumes. The double trace deformation prevents the spontaneous breaking of center symmetry which would otherwise disrupt large N volume independence in small volumes. For small values of N, if the theory is formulated on R 3 xS 1 with a sufficiently small compactification size L, then an analytic treatment of the nonperturbative dynamics of the deformed theory is possible. In this regime, we show that the deformed Yang-Mills theory has a mass gap and exhibits linear confinement. Increasing the circumference L or number of colors N decreases the separation of scales on which the analytic treatment relies. However, there are no order parameters which distinguish the small and large radius regimes. Consequently, for small N the deformed theory provides a novel example of a locally four-dimensional pure-gauge theory in which one has analytic control over confinement, while for large N it provides a simple fully reduced model for Yang-Mills theory. The construction is easily generalized to QCD and other QCD-like theories.

  20. Center-stabilized Yang-Mills Theory:Confinement and Large N Volume Independence

    International Nuclear Information System (INIS)

    Unsal, Mithat; Yaffe, Laurence G.

    2008-01-01

    We examine a double trace deformation of SU(N) Yang-Mills theory which, for large N and large volume, is equivalent to unmodified Yang-Mills theory up to O(1/N 2 ) corrections. In contrast to the unmodified theory, large N volume independence is valid in the deformed theory down to arbitrarily small volumes. The double trace deformation prevents the spontaneous breaking of center symmetry which would otherwise disrupt large N volume independence in small volumes. For small values of N, if the theory is formulated on R 3 x S 1 with a sufficiently small compactification size L, then an analytic treatment of the non-perturbative dynamics of the deformed theory is possible. In this regime, we show that the deformed Yang-Mills theory has a mass gap and exhibits linear confinement. Increasing the circumference L or number of colors N decreases the separation of scales on which the analytic treatment relies. However, there are no order parameters which distinguish the small and large radius regimes. Consequently, for small N the deformed theory provides a novel example of a locally four-dimensional pure gauge theory in which one has analytic control over confinement, while for large N it provides a simple fully reduced model for Yang-Mills theory. The construction is easily generalized to QCD and other QCD-like theories

  1. Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume

    International Nuclear Information System (INIS)

    Malkov, Serghei; Wang, Jeff; Kerlikowske, Karla; Cummings, Steven R.; Shepherd, John A.

    2009-01-01

    Purpose: This study describes the design and characteristics of a highly accurate, precise, and automated single-energy method to quantify percent fibroglandular tissue volume (%FGV) and fibroglandular tissue volume (FGV) using digital screening mammography. Methods: The method uses a breast tissue-equivalent phantom in the unused portion of the mammogram as a reference to estimate breast composition. The phantom is used to calculate breast thickness and composition for each image regardless of x-ray technique or the presence of paddle tilt. The phantom adheres to the top of the mammographic compression paddle and stays in place for both craniocaudal and mediolateral oblique screening views. We describe the automated method to identify the phantom and paddle orientation with a three-dimensional reconstruction least-squares technique. A series of test phantoms, with a breast thickness range of 0.5-8 cm and a %FGV of 0%-100%, were made to test the accuracy and precision of the technique. Results: Using test phantoms, the estimated repeatability standard deviation equaled 2%, with a ±2% accuracy for the entire thickness and density ranges. Without correction, paddle tilt was found to create large errors in the measured density values of up to 7%/mm difference from actual breast thickness. This new density measurement is stable over time, with no significant drifts in calibration noted during a four-month period. Comparisons of %FGV to mammographic percent density and left to right breast %FGV were highly correlated (r=0.83 and 0.94, respectively). Conclusions: An automated method for quantifying fibroglandular tissue volume has been developed. It exhibited good accuracy and precision for a broad range of breast thicknesses, paddle tilt angles, and %FGV values. Clinical testing showed high correlation to mammographic density and between left and right breasts.

  2. PROGRESS ON LARGE GRAIN AND SINGLE GRAIN NIOBIUM: INGOTS AND SHEET AND REVIEW OF PROGRESS ON LARGE GRAIN AND SINGLE GRAIN NIOBIUM CAVITIES

    Energy Technology Data Exchange (ETDEWEB)

    Peter Kneisel

    2008-02-12

    Large grain and single crystal niobium has been proposed several years ago as an alternative material to poly-crystalline niobium for superconducting cavities, exhibiting potential advantages such as ¿stream-lined¿ procedures, reduced costs and better reproducibility in performance. Several major laboratories have investigated the use of large grain and single crystal material in the past years and the niobium producing industry has responded in providing ingot material with enlarged grain sizes. Besides a large number of single cell and multi-cell cavities from large grain niobium, several single crystal cavities have been fabricated and tested with good performances. This contribution will review the progress since the SRF workshop in 2005 in material processing and handling and in cavity performances.

  3. Large Silver Halide Single Crystals as Charged Particle Track Detectors

    Science.gov (United States)

    Kusmiss, J. H.

    1972-01-01

    The trajectory of the particle is made visible under a microscope by the accumulation of metallic silver at regions of the lattice damaged by the particle. This decoration of the particle track is accomplished by exposure of the crystal to light. The decoration of normally present lattice imperfections such as dislocations can be suppressed by the addition to the crystal of less than ten parts per million of a suitable polyvalent metal impurity. An account of some preliminary attempts to grow thin single crystals of AgCl is given also, and suggestions for a more refined technique are offered.

  4. Collection and recruitment of CD34+ cells during large-volume leukapheresis.

    Science.gov (United States)

    Cull, G; Ivey, J; Chase, P; Picciuto, R; Herrmann, R; Cannell, P

    1997-08-01

    Although sufficient progenitor cells for hematopoietic rescue following high-dose therapy may be obtained in a single leukapheresis, the majority of patients require multiple procedures. In an attempt to minimize the number of leukapheresis and maximize collection efficiency, we undertook large-volume leukapheresis in 17 patients with a variety of hematologic malignancies. Twenty-four procedures were performed over a 6-h period, with a mean of 21 L of blood processed. By employing a modified collection set, three separate 2-h collection bags were analyzed for a number of variables. CD34+ cells are collected at a steady rate throughout the procedure, with no evidence of exhaustion of progenitor cells. There was evidence of progenitor cell recruitment, with 1.4-fold more CD34+ cells in the collected product than were present in the blood at the beginning of the procedure. Initiation of leukapheresis was based on the blood CD34+ count, and this value was strongly correlated with the number of CD34+ cells in the collected product. The procedure is safe and relatively simple and minimizes the number of leukaphereses required to collect adequate progenitors for autologous transplantation.

  5. Vision for single flux quantum very large scale integrated technology

    Science.gov (United States)

    Silver, Arnold; Bunyk, Paul; Kleinsasser, Alan; Spargo, John

    2006-05-01

    Single flux quantum (SFQ) electronics is extremely fast and has very low on-chip power dissipation. SFQ VLSI is an excellent candidate for high-performance computing and other applications requiring extremely high-speed signal processing. Despite this, SFQ technology has generally not been accepted for system implementation. We argue that this is due, at least in part, to the use of outdated tools to produce SFQ circuits and chips. Assuming the use of tools equivalent to those employed in the semiconductor industry, we estimate the density of Josephson junctions, circuit speed, and power dissipation that could be achieved with SFQ technology. Today, CMOS lithography is at 90-65 nm with about 20 layers. Assuming equivalent technology, aggressively increasing the current density above 100 kA cm-2 to achieve junction speeds approximately 1000 GHz, and reducing device footprints by converting device profiles from planar to vertical, one could expect to integrate about 250 M Josephson junctions cm-2 into SFQ digital circuits. This should enable circuit operation with clock frequencies above 200 GHz and place approximately 20 K gates within a radius of one clock period. As a result, complete microprocessors, including integrated memory registers, could be fabricated on a single chip. This technology was exported from the United States in accordance with the US Department of Commerce Export Administration Regulations (EAR) for ultimate destination in the United Kingdom. Diversion contrary to US law prohibited.

  6. Vision for single flux quantum very large scale integrated technology

    International Nuclear Information System (INIS)

    Silver, Arnold; Bunyk, Paul; Kleinsasser, Alan; Spargo, John

    2006-01-01

    Single flux quantum (SFQ) electronics is extremely fast and has very low on-chip power dissipation. SFQ VLSI is an excellent candidate for high-performance computing and other applications requiring extremely high-speed signal processing. Despite this, SFQ technology has generally not been accepted for system implementation. We argue that this is due, at least in part, to the use of outdated tools to produce SFQ circuits and chips. Assuming the use of tools equivalent to those employed in the semiconductor industry, we estimate the density of Josephson junctions, circuit speed, and power dissipation that could be achieved with SFQ technology. Today, CMOS lithography is at 90-65 nm with about 20 layers. Assuming equivalent technology, aggressively increasing the current density above 100 kA cm -2 to achieve junction speeds approximately 1000 GHz, and reducing device footprints by converting device profiles from planar to vertical, one could expect to integrate about 250 M Josephson junctions cm -2 into SFQ digital circuits. This should enable circuit operation with clock frequencies above 200 GHz and place approximately 20 K gates within a radius of one clock period. As a result, complete microprocessors, including integrated memory registers, could be fabricated on a single chip

  7. Development of large-volume rhyolitic ignibrites (LRI'S): The Chalupas Caldera, an example from Ecuador

    International Nuclear Information System (INIS)

    Hammersley, L.; DePaolo, D.J; Beate, B

    2001-01-01

    The mechanisms responsible for the generation of large volumes of silicic magma and the eruption of large-volume rhyolitic ignimbrites (LRI's) remain poorly understood. Of particular interest are the relative roles of crustal assimilation, fractional crystallization and magma supply and the processes by which large volumes of magma accumulate in crustal chambers rather than erupt in smaller batches. Isotope geochemistry, combined with study of major and trace element variations of lavas, can be used to infer the relative contribution of crustal material and continued magmatic supply. Timescales for the accumulation of magma can be estimated using detailed geochronology. Magma supply rates can be estimated from eruption rates of nearby volcanoes. In this study we investigate the evolution of the Chalupas LRI, a caldera system in the Ecuadorian Andes where LRI's are rare in comparison to the Southern Volcanic Zone (SVZ) of South America (au)

  8. 70 GeV proton volume capture into channeling mode with a bent Si single crystal

    International Nuclear Information System (INIS)

    Chesnokov, Yu.A.; Galyaev, N.A.; Kotov, V.I.; Tsarik, S.V.; Zapol'skij, V.N.

    1990-01-01

    The existence of the volume capture of 70 GeV protons with a Si bent single crystal of (111) orientation into the channeling mode gas experimentally been proved. The data on the probability of capturing protons into the channeling mode versus the bending radius of the crystal have been obtained together with the information on the dynamics of volume captured particle dechanneling. 10 refs

  9. Feasibility of large volume casting cementation process for intermediate level radioactive waste

    International Nuclear Information System (INIS)

    Chen Zhuying; Chen Baisong; Zeng Jishu; Yu Chengze

    1988-01-01

    The recent tendency of radioactive waste treatment and disposal both in China and abroad is reviewed. The feasibility of the large volume casting cementation process for treating and disposing the intermediate level radioactive waste from spent fuel reprocessing plant in shallow land is assessed on the basis of the analyses of the experimental results (such as formulation study, solidified radioactive waste properties measurement ect.). It can be concluded large volume casting cementation process is a promising, safe and economic process. It is feasible to dispose the intermediate level radioactive waste from reprocessing plant it the disposal site chosen has resonable geological and geographical conditions and some additional effective protection means are taken

  10. Rejecting escape events in large volume Ge detectors by a pulse shape selection procedure

    Energy Technology Data Exchange (ETDEWEB)

    Del Zoppo, A. (Istituto Nazionale di Fisica Nucleare - Laboratorio Nazionale del Sud, Catania (Italy)); Agodi, C. (Istituto Nazionale di Fisica Nucleare - Laboratorio Nazionale del Sud, Catania (Italy)); Alba, R. (Istituto Nazionale di Fisica Nucleare - Laboratorio Nazionale del Sud, Catania (Italy)); Bellia, G. (Istituto Nazionale di Fisica Nucleare - Laboratorio Nazionale del Sud, Catania (Italy) Dipartimento di Fisica dell' Universita, Catania (Italy)); Coniglione, R. (Istituto Nazionale di Fisica Nucleare - Laboratorio Nazionale del Sud, Catania (Italy)); Loukachine, K. (Istituto Nazionale di Fisica Nucleare - Laboratorio Nazionale del Sud, Catania (Italy)); Maiolino, C. (Istituto Nazionale di Fisica Nucleare - Laboratorio Nazionale del Sud, Catania (Italy)); Migneco, E. (Istituto Nazionale di Fisica Nucleare - Laboratorio Nazionale del Sud, Catania (Italy) Dipartimento di Fisica dell' Universita, Catania (Italy)); Piattelli, P. (Istituto Nazionale di Fisica Nucleare - Labora

    1993-10-01

    The dependence of the response to [gamma]-rays of a large volume Ge detector on the interval width of a selected initial rise pulse slope is investigated. The number of escape events associated with a small pulse slope is found to be greater than the corresponding number of full energy events. An escape event rejection procedure based on the observed correlation between energy deposition and pulse shape is discussed. Such a procedure seems particularly suited for the design of highly granular large volume Ge detector arrays. (orig.)

  11. Rejecting escape events in large volume Ge detectors by a pulse shape selection procedure

    International Nuclear Information System (INIS)

    Del Zoppo, A.; Agodi, C.; Alba, R.; Bellia, G.; Coniglione, R.; Loukachine, K.; Maiolino, C.; Migneco, E.; Piattelli, P.; Santonocito, D.; Sapienza, P.

    1993-01-01

    The dependence of the response to γ-rays of a large volume Ge detector on the interval width of a selected initial rise pulse slope is investigated. The number of escape events associated with a small pulse slope is found to be greater than the corresponding number of full energy events. An escape event rejection procedure based on the observed correlation between energy deposition and pulse shape is discussed. Such a procedure seems particularly suited for the design of highly granular large volume Ge detector arrays. (orig.)

  12. Prey Selection of Scandinavian Wolves: Single Large or Several Small?

    Science.gov (United States)

    Sand, Håkan; Eklund, Ann; Zimmermann, Barbara; Wikenros, Camilla; Wabakken, Petter

    2016-01-01

    Research on large predator-prey interactions are often limited to the predators' primary prey, with the potential for prey switching in systems with multiple ungulate species rarely investigated. We evaluated wolf (Canis lupus) prey selection at two different spatial scales, i.e., inter- and intra-territorial, using data from 409 ungulate wolf-kills in an expanding wolf population in Scandinavia. This expansion includes a change from a one-prey into a two-prey system with variable densities of one large-sized ungulate; moose (Alces alces) and one small-sized ungulate; roe deer (Capreolus capreolus). Among wolf territories, the proportion of roe deer in wolf kills was related to both pack size and roe deer density, but not to moose density. Pairs of wolves killed a higher proportion of roe deer than did packs, and wolves switched to kill more roe deer as their density increased above a 1:1 ratio in relation to the availability of the two species. At the intra-territorial level, wolves again responded to changes in roe deer density in their prey selection whereas we found no effect of snow depth, time during winter, or other predator-related factors on the wolves' choice to kill moose or roe deer. Moose population density was only weakly related to intra-territorial prey selection. Our results show that the functional response of wolves on moose, the species hitherto considered as the main prey, was strongly dependent on the density of a smaller, alternative, ungulate prey. The impact of wolf predation on the prey species community is therefore likely to change with the composition of the multi-prey species community along with the geographical expansion of the wolf population.

  13. Prey Selection of Scandinavian Wolves: Single Large or Several Small?

    Science.gov (United States)

    Eklund, Ann; Zimmermann, Barbara; Wikenros, Camilla; Wabakken, Petter

    2016-01-01

    Research on large predator-prey interactions are often limited to the predators’ primary prey, with the potential for prey switching in systems with multiple ungulate species rarely investigated. We evaluated wolf (Canis lupus) prey selection at two different spatial scales, i.e., inter- and intra-territorial, using data from 409 ungulate wolf-kills in an expanding wolf population in Scandinavia. This expansion includes a change from a one-prey into a two-prey system with variable densities of one large-sized ungulate; moose (Alces alces) and one small-sized ungulate; roe deer (Capreolus capreolus). Among wolf territories, the proportion of roe deer in wolf kills was related to both pack size and roe deer density, but not to moose density. Pairs of wolves killed a higher proportion of roe deer than did packs, and wolves switched to kill more roe deer as their density increased above a 1:1 ratio in relation to the availability of the two species. At the intra-territorial level, wolves again responded to changes in roe deer density in their prey selection whereas we found no effect of snow depth, time during winter, or other predator-related factors on the wolves’ choice to kill moose or roe deer. Moose population density was only weakly related to intra-territorial prey selection. Our results show that the functional response of wolves on moose, the species hitherto considered as the main prey, was strongly dependent on the density of a smaller, alternative, ungulate prey. The impact of wolf predation on the prey species community is therefore likely to change with the composition of the multi-prey species community along with the geographical expansion of the wolf population. PMID:28030549

  14. Rapid estimate of solid volume in large tuff cores using a gas pycnometer

    Energy Technology Data Exchange (ETDEWEB)

    Thies, C. [ed.; Geddis, A.M.; Guzman, A.G. [and others

    1996-09-01

    A thermally insulated, rigid-volume gas pycnometer system has been developed. The pycnometer chambers have been machined from solid PVC cylinders. Two chambers confine dry high-purity helium at different pressures. A thick-walled design ensures minimal heat exchange with the surrounding environment and a constant volume system, while expansion takes place between the chambers. The internal energy of the gas is assumed constant over the expansion. The ideal gas law is used to estimate the volume of solid material sealed in one of the chambers. Temperature is monitored continuously and incorporated into the calculation of solid volume. Temperature variation between measurements is less than 0.1{degrees}C. The data are used to compute grain density for oven-dried Apache Leap tuff core samples. The measured volume of solid and the sample bulk volume are used to estimate porosity and bulk density. Intrinsic permeability was estimated from the porosity and measured pore surface area and is compared to in-situ measurements by the air permeability method. The gas pycnometer accommodates large core samples (0.25 m length x 0.11 m diameter) and can measure solid volume greater than 2.20 cm{sup 3} with less than 1% error.

  15. Optimization of the electric field distribution in a large volume tissue-equivalent proportional counter

    International Nuclear Information System (INIS)

    Verma, P.K.; Waker, A.J.

    1992-01-01

    Large volume tissue-equivalent proportional counters are of interest in radiation protection metrology, as the sensitivity in terms of counts per unit absorbed dose in these devices increases as the square of the counter diameter. Conventional solutions to the problem of maintaining a uniform electric field within a counter result in sensitive volume to total volume ratios which are unacceptably low when counter dimensions of the order of 15 cm diameter are considered and when overall compactness is an important design criterion. This work describes the design and optimization of an arrangement of field discs set at different potentials which enable sensitive volume to total volume ratios to approach unity. The method has been used to construct a 12.7 cm diameter right-cylindrical tissue-equivalent proportional counter in which the sensitive volume accounts for over 95% of the total device volume and the gas gain uniformity is maintained to within 3% along the entire length of the anode wire. (author)

  16. Rapid estimate of solid volume in large tuff cores using a gas pycnometer

    International Nuclear Information System (INIS)

    Thies, C.; Geddis, A.M.; Guzman, A.G.

    1996-09-01

    A thermally insulated, rigid-volume gas pycnometer system has been developed. The pycnometer chambers have been machined from solid PVC cylinders. Two chambers confine dry high-purity helium at different pressures. A thick-walled design ensures minimal heat exchange with the surrounding environment and a constant volume system, while expansion takes place between the chambers. The internal energy of the gas is assumed constant over the expansion. The ideal gas law is used to estimate the volume of solid material sealed in one of the chambers. Temperature is monitored continuously and incorporated into the calculation of solid volume. Temperature variation between measurements is less than 0.1 degrees C. The data are used to compute grain density for oven-dried Apache Leap tuff core samples. The measured volume of solid and the sample bulk volume are used to estimate porosity and bulk density. Intrinsic permeability was estimated from the porosity and measured pore surface area and is compared to in-situ measurements by the air permeability method. The gas pycnometer accommodates large core samples (0.25 m length x 0.11 m diameter) and can measure solid volume greater than 2.20 cm 3 with less than 1% error

  17. Capillary gas chromatographic analysis of nerve agents using large volume injections

    NARCIS (Netherlands)

    Degenhardt, C.E.A.M.; Kientz, C.E.

    1996-01-01

    The use of large volume injections has been studied for the verification of intact organophosphorus chemical warfare agents in water samples. As the use of ethyl acetate caused severe detection problems new potential solvents were evaluated. With the developed procedure, the nerve agents sarin,

  18. Large volume liquid silicone injection in the upper thighs : a never ending story

    NARCIS (Netherlands)

    Hofer, SOP; Damen, A; Nicolai, JPA

    This report concerns a 26-year-old male-to-female transsexual who had received a large volume liquid silicone injection of unknown grade into her upper lateral thighs to gain female contour. She presented at our outpatient clinic 4 years after the silicone injection with complaints of pain and

  19. The impact of large tidal volume ventilation on the absorption of inhaled insulin in rabbits

    DEFF Research Database (Denmark)

    Petersen, Astrid Heide; Laursen, Torben; Ahrén, Bo

    2007-01-01

    Previous studies have shown that ventilation patterns affect absorption of inhaled compounds. Thus, the aim of this study was to investigate the effect of large tidal volume ventilation (LTVV) on the absorption of inhaled insulin in rabbits. Mechanically ventilated rabbits were given human insulin...

  20. Development of a Solid Phase Extraction Method for Agricultural Pesticides in Large-Volume Water Samples

    Science.gov (United States)

    An analytical method using solid phase extraction (SPE) and analysis by gas chromatography/mass spectrometry (GC/MS) was developed for the trace determination of a variety of agricultural pesticides and selected transformation products in large-volume high-elevation lake water sa...

  1. Fabrication process for a large volume silicon nitride micro-combustor

    NARCIS (Netherlands)

    Zhao, Yiyuan; Veltkamp, Henk-Willem; de Boer, Meint J.; Zeng, Yaxiang; Groenesteijn, Jarno; Wiegerink, Remco J.; Lötters, Joost Conrad

    2017-01-01

    Micro-channels with large internal volumes are desired in highly exothermal micro-reactors, such as an integrated Wobbe index meter with on-chip microscale natural gas combustion and localized temperature sensing, or a propellant micro-thruster. State of the art experimental studies on microscale

  2. The use of cosmic muons in detecting heterogeneities in large volumes

    International Nuclear Information System (INIS)

    Grabski, V.; Reche, R.; Alfaro, R.; Belmont-Moreno, E.; Martinez-Davalos, A.; Sandoval, A.; Menchaca-Rocha, A.

    2008-01-01

    The muon intensity attenuation method to detect heterogeneities in large matter volumes is analyzed. Approximate analytical expressions to estimate the collection time and the signal to noise ratio, are proposed and validated by Monte Carlo simulations. Important parameters, including point spread function and coordinate reconstruction uncertainty are also estimated using Monte Carlo simulations

  3. Populating the Large-Wavevector Realm: Bloch Volume Plasmon Polaritons in Hyperbolic and Extremely Anisotropic Metamaterials

    DEFF Research Database (Denmark)

    Zhukovsky, Sergei; Babicheva, Viktoriia; Orlov, A. A.

    2014-01-01

    Optics of hyperbolic metamaterials is revisited in terms of large-wavevector waves, evanescent in isotropic media but propagating in presence of extreme anisotropy. Identifying the physical nature of these waves as Bloch volume plasmon polaritons, we derive their existence conditions and outline ...

  4. Absolute activity determinations on large volume geological samples independent of self-absorption effects

    International Nuclear Information System (INIS)

    Wilson, W.E.

    1980-01-01

    This paper describes a method for measuring the absolute activity of large volume samples by γ-spectroscopy independent of self-absorption effects using Ge detectors. The method yields accurate matrix independent results at the expense of replicative counting of the unknown sample. (orig./HP)

  5. SparseLeap: Efficient Empty Space Skipping for Large-Scale Volume Rendering.

    Science.gov (United States)

    Hadwiger, Markus; Al-Awami, Ali K; Beyer, Johanna; Agus, Marco; Pfister, Hanspeter

    2018-01-01

    Recent advances in data acquisition produce volume data of very high resolution and large size, such as terabyte-sized microscopy volumes. These data often contain many fine and intricate structures, which pose huge challenges for volume rendering, and make it particularly important to efficiently skip empty space. This paper addresses two major challenges: (1) The complexity of large volumes containing fine structures often leads to highly fragmented space subdivisions that make empty regions hard to skip efficiently. (2) The classification of space into empty and non-empty regions changes frequently, because the user or the evaluation of an interactive query activate a different set of objects, which makes it unfeasible to pre-compute a well-adapted space subdivision. We describe the novel SparseLeap method for efficient empty space skipping in very large volumes, even around fine structures. The main performance characteristic of SparseLeap is that it moves the major cost of empty space skipping out of the ray-casting stage. We achieve this via a hybrid strategy that balances the computational load between determining empty ray segments in a rasterization (object-order) stage, and sampling non-empty volume data in the ray-casting (image-order) stage. Before ray-casting, we exploit the fast hardware rasterization of GPUs to create a ray segment list for each pixel, which identifies non-empty regions along the ray. The ray-casting stage then leaps over empty space without hierarchy traversal. Ray segment lists are created by rasterizing a set of fine-grained, view-independent bounding boxes. Frame coherence is exploited by re-using the same bounding boxes unless the set of active objects changes. We show that SparseLeap scales better to large, sparse data than standard octree empty space skipping.

  6. SparseLeap: Efficient Empty Space Skipping for Large-Scale Volume Rendering

    KAUST Repository

    Hadwiger, Markus

    2017-08-28

    Recent advances in data acquisition produce volume data of very high resolution and large size, such as terabyte-sized microscopy volumes. These data often contain many fine and intricate structures, which pose huge challenges for volume rendering, and make it particularly important to efficiently skip empty space. This paper addresses two major challenges: (1) The complexity of large volumes containing fine structures often leads to highly fragmented space subdivisions that make empty regions hard to skip efficiently. (2) The classification of space into empty and non-empty regions changes frequently, because the user or the evaluation of an interactive query activate a different set of objects, which makes it unfeasible to pre-compute a well-adapted space subdivision. We describe the novel SparseLeap method for efficient empty space skipping in very large volumes, even around fine structures. The main performance characteristic of SparseLeap is that it moves the major cost of empty space skipping out of the ray-casting stage. We achieve this via a hybrid strategy that balances the computational load between determining empty ray segments in a rasterization (object-order) stage, and sampling non-empty volume data in the ray-casting (image-order) stage. Before ray-casting, we exploit the fast hardware rasterization of GPUs to create a ray segment list for each pixel, which identifies non-empty regions along the ray. The ray-casting stage then leaps over empty space without hierarchy traversal. Ray segment lists are created by rasterizing a set of fine-grained, view-independent bounding boxes. Frame coherence is exploited by re-using the same bounding boxes unless the set of active objects changes. We show that SparseLeap scales better to large, sparse data than standard octree empty space skipping.

  7. Laue diffraction: The key to neutron crystallography from submillimetric-volume single crystals

    Science.gov (United States)

    Lemée-Cailleau, M.-H.; McIntyre, G. J.; Wilkinson, C.

    2005-12-01

    For several decades, chemists and physicists have been fascinated by molecular compounds rich in delocalized electrons. In the solid state these compounds may offer a very rich fan of properties: optical, conduction and dielectric, magneticldots Each state is the result of a delicate balance amongst intra- and/or intermolecular interactions which can be controlled, not just by direct chemical substitution, but also by external parameters such as temperature, pressure, continuous electric or magnetic fields, or by light. The recent evolution of this field of science towards more and more sophisticated materials makes also more and more difficult their crystal growth. While neutron scattering is an extremely powerful technique to get precise structural information, it is also often disregarded in this field because usually large single crystals are required. With the recent renaissance of Laue techniques using the very intense flux provided by the reactor of the Institut Laue-Langevin (ILL), accurate structural and/or magnetic information can be now extracted routinely from molecular crystals of volume 0.1 mm3 or smaller, with easy possibilities of high pressure (up to 3 GPa) down to 0.2 K. A general survey of these new possibilities is illustrated by an example taken from the field of low-dimensional organic complexes.

  8. A general method for assessing the effects of uncertainty in individual-tree volume model predictions on large-area volume estimates with a subtropical forest illustration

    Science.gov (United States)

    Ronald E. McRoberts; Paolo Moser; Laio Zimermann Oliveira; Alexander C. Vibrans

    2015-01-01

    Forest inventory estimates of tree volume for large areas are typically calculated by adding the model predictions of volumes for individual trees at the plot level, calculating the mean over plots, and expressing the result on a per unit area basis. The uncertainty in the model predictions is generally ignored, with the result that the precision of the large-area...

  9. GPU-Based 3D Cone-Beam CT Image Reconstruction for Large Data Volume

    Directory of Open Access Journals (Sweden)

    Xing Zhao

    2009-01-01

    Full Text Available Currently, 3D cone-beam CT image reconstruction speed is still a severe limitation for clinical application. The computational power of modern graphics processing units (GPUs has been harnessed to provide impressive acceleration of 3D volume image reconstruction. For extra large data volume exceeding the physical graphic memory of GPU, a straightforward compromise is to divide data volume into blocks. Different from the conventional Octree partition method, a new partition scheme is proposed in this paper. This method divides both projection data and reconstructed image volume into subsets according to geometric symmetries in circular cone-beam projection layout, and a fast reconstruction for large data volume can be implemented by packing the subsets of projection data into the RGBA channels of GPU, performing the reconstruction chunk by chunk and combining the individual results in the end. The method is evaluated by reconstructing 3D images from computer-simulation data and real micro-CT data. Our results indicate that the GPU implementation can maintain original precision and speed up the reconstruction process by 110–120 times for circular cone-beam scan, as compared to traditional CPU implementation.

  10. A pomegranate-inspired nanoscale design for large-volume-change lithium battery anodes

    Science.gov (United States)

    Liu, Nian; Lu, Zhenda; Zhao, Jie; McDowell, Matthew T.; Lee, Hyun-Wook; Zhao, Wenting; Cui, Yi

    2014-03-01

    Silicon is an attractive material for anodes in energy storage devices, because it has ten times the theoretical capacity of its state-of-the-art carbonaceous counterpart. Silicon anodes can be used both in traditional lithium-ion batteries and in more recent Li-O2 and Li-S batteries as a replacement for the dendrite-forming lithium metal anodes. The main challenges associated with silicon anodes are structural degradation and instability of the solid-electrolyte interphase caused by the large volume change (~300%) during cycling, the occurrence of side reactions with the electrolyte, and the low volumetric capacity when the material size is reduced to a nanometre scale. Here, we propose a hierarchical structured silicon anode that tackles all three of these problems. Our design is inspired by the structure of a pomegranate, where single silicon nanoparticles are encapsulated by a conductive carbon layer that leaves enough room for expansion and contraction following lithiation and delithiation. An ensemble of these hybrid nanoparticles is then encapsulated by a thicker carbon layer in micrometre-size pouches to act as an electrolyte barrier. As a result of this hierarchical arrangement, the solid-electrolyte interphase remains stable and spatially confined, resulting in superior cyclability (97% capacity retention after 1,000 cycles). In addition, the microstructures lower the electrode-electrolyte contact area, resulting in high Coulombic efficiency (99.87%) and volumetric capacity (1,270 mAh cm-3), and the cycling remains stable even when the areal capacity is increased to the level of commercial lithium-ion batteries (3.7 mAh cm-2).

  11. Gradient rotating outer volume excitation (GROOVE): A novel method for single-shot two-dimensional outer volume suppression.

    Science.gov (United States)

    Powell, Nathaniel J; Jang, Albert; Park, Jang-Yeon; Valette, Julien; Garwood, Michael; Marjańska, Małgorzata

    2015-01-01

    To introduce a new outer volume suppression (OVS) technique that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called gradient rotating outer volume excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing the entire outer volume. Theoretical and k-space descriptions of GROOVE are provided. The properties of GROOVE were investigated with simulations, phantom, and human experiments performed using a 4T horizontal bore magnet equipped with a TEM coil. Similar suppression performance was obtained in phantom and human brain using GROOVE with circular and elliptical shapes. Simulations indicate that GROOVE requires less SAR and time than traditional OVS schemes, but traditional schemes provide a sharper transition zone and less residual signal. GROOVE represents a new way of performing OVS in which spins are excited temporally in space on a trajectory that can be tailored to fit the shape of the suppression region. In addition, GROOVE is capable of suppressing tailored regions of space with more flexibility and in a shorter period of time than conventional methods. GROOVE provides a fast, low SAR alternative to conventional OVS methods in some applications (e.g., scalp suppression). © 2014 Wiley Periodicals, Inc.

  12. Absorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes

    International Nuclear Information System (INIS)

    Binzoni, T; Leung, T S; Ruefenacht, D; Delpy, D T

    2006-01-01

    Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of the tissue, and the scattering coefficient of the red blood cells. The model holds for anisotropic scattering and for multiple scattering of the photons by the moving scatterers of finite size. In particular, it has also been possible to take into account the simultaneous presence of both Brownian and pure translational movements. An analytical and simplified version of the model has also been derived and its validity investigated, for the case of measurements in human skeletal muscle tissue. It is shown that at large optode spacing it is possible to use the simplified model, taking into account only a 'mean' light pathlength, to predict the blood flow related parameters. It is also demonstrated that the 'classical' blood volume parameter, derived from LDF instruments, may not represent the actual blood volume variations when the investigated tissue volume is large. The simplified model does not need knowledge of the tissue optical parameters and thus should allow the development of very simple and cost-effective LDF hardware

  13. Large-Scale Multi-Resolution Representations for Accurate Interactive Image and Volume Operations

    KAUST Repository

    Sicat, Ronell B.

    2015-11-25

    The resolutions of acquired image and volume data are ever increasing. However, the resolutions of commodity display devices remain limited. This leads to an increasing gap between data and display resolutions. To bridge this gap, the standard approach is to employ output-sensitive operations on multi-resolution data representations. Output-sensitive operations facilitate interactive applications since their required computations are proportional only to the size of the data that is visible, i.e., the output, and not the full size of the input. Multi-resolution representations, such as image mipmaps, and volume octrees, are crucial in providing these operations direct access to any subset of the data at any resolution corresponding to the output. Despite its widespread use, this standard approach has some shortcomings in three important application areas, namely non-linear image operations, multi-resolution volume rendering, and large-scale image exploration. This dissertation presents new multi-resolution representations for large-scale images and volumes that address these shortcomings. Standard multi-resolution representations require low-pass pre-filtering for anti- aliasing. However, linear pre-filters do not commute with non-linear operations. This becomes problematic when applying non-linear operations directly to any coarse resolution levels in standard representations. Particularly, this leads to inaccurate output when applying non-linear image operations, e.g., color mapping and detail-aware filters, to multi-resolution images. Similarly, in multi-resolution volume rendering, this leads to inconsistency artifacts which manifest as erroneous differences in rendering outputs across resolution levels. To address these issues, we introduce the sparse pdf maps and sparse pdf volumes representations for large-scale images and volumes, respectively. These representations sparsely encode continuous probability density functions (pdfs) of multi-resolution pixel

  14. Comparison of bone volume measurements using conventional single and dual energy computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yung Kyoon; Park, Sang Hoon [Dept. of Radiology, Samsung Medical Center, Seoul (Korea, Republic of); Kim, Yon Min [Dept. of Radiotechnology, Wonkwang Health Science University, Iksan (Korea, Republic of)

    2017-06-15

    The study examines changes in calcium volume on born by comparing two figures; one is measured by dual energy computed tomography(DECT) followed by applying variation in monochromatic energy selection( keV), material decomposition(MD), and material suppressed iodine(MSI) analysis, and the other is measured by conventional single source computed tomography(CSCT). For this study, based on CSCT images taken by using human mimicked phantom, 70, 100, 140 keV and MSI, MD material calcium weighting( MCW) and MD material iodine weighting(MIW) of DECT were applied respectively. Then calculated calcium volume was converted to Agatston score for comparison. Volume of human mimicked phantom was in inverse proportion to keV. The volume decreased while keV increased(p<0.05). The most similar DECT volumes were reconstructed at 70 keV, the difference was showed 35.8±12.2 for rib, femur (16.1±24.1), pelvis(13.7±18.8), and spine(179.0±61.8). However, the volume of MSI was down for each organ; the volume of rib was 5.55%, femur(76.34%), pelvis(55.16%) and spine(87.58%). The volume of MSI decreased 55.9% for rib, femur(80.7%), pelvis(69.6%) and spine(54.2%) while MD MIW reduced for rib(83.51%), femur(87.68%), pelvis(86.64%), and spine(82.62%). With the results, the study found that outcomes were affected by the method which examiners employed. When using DECT, calcium volume of born dropped with keV increased. It also found that the most similar DECT images were reconstructed at 70 keV. The results of experiments implied that the users of MSI and MD should be cautious of errors as there are big differences in scores between those two methods.

  15. Effect, Feasibility, and Clinical Relevance of Cell Enrichment in Large Volume Fat Grafting

    DEFF Research Database (Denmark)

    Rasmussen, Bo Sonnich; Lykke Sørensen, Celine; Vester-Glowinski, Peter Viktor

    2017-01-01

    Large volume fat grafting is limited by unpredictable volume loss; therefore, methods of improving graft retention have been developed. Fat graft enrichment with either stromal vascular fraction (SVF) cells or adipose tissue-derived stem/stromal cells (ASCs) has been investigated in several animal...... and human studies, and significantly improved graft retention has been reported. Improvement of graft retention and the feasibility of these techniques are equally important in evaluating the clinical relevance of cell enrichment. We conducted a systematic search of PubMed to identify studies on fat graft...... enrichment that used either SVF cells or ASCs, and only studies reporting volume assessment were included. A total of 38 articles (15 human and 23 animal) were included to investigate the effects of cell enrichment on graft retention as well as the feasibility and clinical relevance of cell-enriched fat...

  16. Recurrence in Benign Paroxysmal Positional Vertigo: A Large, Single-Institution Study.

    Science.gov (United States)

    Luryi, Alexander L; Lawrence, Juliana; Bojrab, Dennis I; LaRouere, Michael; Babu, Seilesh; Zappia, John; Sargent, Eric W; Chan, Eleanor; Naumann, Ilka; Hong, Robert S; Schutt, Christopher A

    2018-04-11

    To report rates of recurrence in benign paroxysmal positional vertigo (BPPV) and associated patient and disease factors. Retrospective chart review. Single high-volume otology practice. Patients diagnosed with BPPV from 2007 to 2016 with documented resolution of symptoms. Diagnostic and particle repositioning maneuvers for BPPV. BPPV recurrence, time to recurrence, and ear(s) affected at recurrence. A total of 1,105 patients meeting criteria were identified. Of this population, 37% had recurrence of BPPV in either ear or both ears. Overall same-ear recurrence rate was 28%; 76% of recurrences involved the same ear(s) as initial presentation. Recurrences that occurred after longer disease-free intervals were more likely to involve the opposite ear than early recurrences (p = 0.02). Female sex (40.4% versus 32.7%, p = 0.01) and history of previous BPPV (57.5% versus 32.4%, p diabetes mellitus, and traumatic etiology were not. Approximately, half (56%) of recurrences occurred within 1 year of resolution. A large single-institution study of recurrence in BPPV is presented along with Kaplan-Meier disease-free survival curves. Female sex and history of previous BPPV were associated with increased recurrence, while previously suspected risk factors for recurrence including history of Menière's disease, diabetes, and trauma were not. Remote recurrence is more likely to involve the contralateral ear than early recurrence. These data solidify the expected course of treated BPPV allowing for improved clinical care and patient counseling.

  17. Intraoperative ventilation: incidence and risk factors for receiving large tidal volumes during general anesthesia

    Directory of Open Access Journals (Sweden)

    Fernandez-Bustamante Ana

    2011-11-01

    Full Text Available Abstract Background There is a growing concern of the potential injurious role of ventilatory over-distention in patients without lung injury. No formal guidelines exist for intraoperative ventilation settings, but the use of tidal volumes (VT under 10 mL/kg predicted body weight (PBW has been recommended in healthy patients. We explored the incidence and risk factors for receiving large tidal volumes (VT > 10 mL/kg PBW. Methods We performed a cross-sectional analysis of our prospectively collected perioperative electronic database for current intraoperative ventilation practices and risk factors for receiving large tidal volumes (VT > 10 mL/kg PBW. We included all adults undergoing prolonged (≥ 4 h elective abdominal surgery and collected demographic, preoperative (comorbidities, intraoperative (i.e. ventilatory settings, fluid administration and postoperative (outcomes information. We compared patients receiving exhaled tidal volumes > 10 mL/kg PBW with those that received 8-10 or Results Ventilatory settings were non-uniform in the 429 adults included in the analysis. 17.5% of all patients received VT > 10 mL/kg PBW. 34.0% of all obese patients (body mass index, BMI, ≥ 30, 51% of all patients with a height T > 10 mL/kg PBW. Conclusions Ventilation with VT > 10 mL/kg PBW is still common, although poor correlation with PBW suggests it may be unintentional. BMI ≥ 30, female gender and height

  18. Geophysics Under Pressure: Large-Volume Presses Versus the Diamond-Anvil Cell

    Science.gov (United States)

    Hazen, R. M.

    2002-05-01

    Prior to 1970, the legacy of Harvard physicist Percy Bridgman dominated high-pressure geophysics. Massive presses with large-volume devices, including piston-cylinder, opposed-anvil, and multi-anvil configurations, were widely used in both science and industry to achieve a range of crustal and upper mantle temperatures and pressures. George Kennedy of UCLA was a particularly influential advocate of large-volume apparatus for geophysical research prior to his death in 1980. The high-pressure scene began to change in 1959 with the invention of the diamond-anvil cell, which was designed simultaneously and independently by John Jamieson at the University of Chicago and Alvin Van Valkenburg at the National Bureau of Standards in Washington, DC. The compact, inexpensive diamond cell achieved record static pressures and had the advantage of optical access to the high-pressure environment. Nevertheless, members of the geophysical community, who favored the substantial sample volumes, geothermally relevant temperature range, and satisfying bulk of large-volume presses, initially viewed the diamond cell with indifference or even contempt. Several factors led to a gradual shift in emphasis from large-volume presses to diamond-anvil cells in geophysical research during the 1960s and 1970s. These factors include (1) their relatively low cost at time of fiscal restraint, (2) Alvin Van Valkenburg's new position as a Program Director at the National Science Foundation in 1964 (when George Kennedy's proposal for a Nation High-Pressure Laboratory was rejected), (3) the development of lasers and micro-analytical spectroscopic techniques suitable for analyzing samples in a diamond cell, and (4) the attainment of record pressures (e.g., 100 GPa in 1975 by Mao and Bell at the Geophysical Laboratory). Today, a more balanced collaborative approach has been adopted by the geophysics and mineral physics community. Many high-pressure laboratories operate a new generation of less expensive

  19. Assembly, operation and disassembly manual for the Battelle Large Volume Water Sampler (BLVWS)

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, V.W.; Campbell, R.M.

    1984-12-01

    Assembly, operation and disassembly of the Battelle Large Volume Water Sampler (BLVWS) are described in detail. Step by step instructions of assembly, general operation and disassembly are provided to allow an operator completely unfamiliar with the sampler to successfully apply the BLVWS to his research sampling needs. The sampler permits concentration of both particulate and dissolved radionuclides from large volumes of ocean and fresh water. The water sample passes through a filtration section for particle removal then through sorption or ion exchange beds where species of interest are removed. The sampler components which contact the water being sampled are constructed of polyvinylchloride (PVC). The sampler has been successfully applied to many sampling needs over the past fifteen years. 9 references, 8 figures.

  20. Measurement of Atmospheric Neutrino Oscillations with Very Large Volume Neutrino Telescopes

    Directory of Open Access Journals (Sweden)

    J. P. Yáñez

    2015-01-01

    Full Text Available Neutrino oscillations have been probed during the last few decades using multiple neutrino sources and experimental set-ups. In the recent years, very large volume neutrino telescopes have started contributing to the field. First ANTARES and then IceCube have relied on large and sparsely instrumented volumes to observe atmospheric neutrinos for combinations of baselines and energies inaccessible to other experiments. Using this advantage, the latest result from IceCube starts approaching the precision of other established technologies and is paving the way for future detectors, such as ORCA and PINGU. These new projects seek to provide better measurements of neutrino oscillation parameters and eventually determine the neutrino mass ordering. The results from running experiments and the potential from proposed projects are discussed in this review, emphasizing the experimental challenges involved in the measurements.

  1. Management of Large Volumes of Waste Arising in a Nuclear or Radiological Emergency

    International Nuclear Information System (INIS)

    2017-10-01

    This publication, prepared in light of the IAEA Action Plan on Nuclear Safety developed after the accident at the Fukushima Daiichi nuclear power plant, addresses the management of large volumes of radioactive waste arising in a nuclear or radiological emergency, as part of overall emergency preparedness. The management of large volumes of waste will be one of many efforts to be dealt with to allow recovery of affected areas, to support return of evacuated or relocated populations and preparations for normal social and economic activities, and/or to mitigate additional environmental impacts. The publication is intended to be of use to national planners and policy makers, facility and programme managers, and other professionals responsible for developing and implementing national plans and strategies to manage radioactive waste arising from nuclear or radiological emergencies.

  2. Assembly, operation and disassembly manual for the Battelle Large Volume Water Sampler (BLVWS)

    International Nuclear Information System (INIS)

    Thomas, V.W.; Campbell, R.M.

    1984-12-01

    Assembly, operation and disassembly of the Battelle Large Volume Water Sampler (BLVWS) are described in detail. Step by step instructions of assembly, general operation and disassembly are provided to allow an operator completely unfamiliar with the sampler to successfully apply the BLVWS to his research sampling needs. The sampler permits concentration of both particulate and dissolved radionuclides from large volumes of ocean and fresh water. The water sample passes through a filtration section for particle removal then through sorption or ion exchange beds where species of interest are removed. The sampler components which contact the water being sampled are constructed of polyvinylchloride (PVC). The sampler has been successfully applied to many sampling needs over the past fifteen years. 9 references, 8 figures

  3. Compatibility of verapamil hydrochloride injection in commonly used large-volume parenterals.

    Science.gov (United States)

    Cutie, M R; Lordi, N G

    1980-05-01

    The visual and chemical compatibilities of verapamil hydrochloride injection in 10 commonly used large-volume solutions packaged in glass, polyolefin, or polyvinyl chloride containers were studied. The mixtures, each containing 40 mg/liter of verapamil hydrochloride, were stored away from light for up to 48 hours at 25 degrees C. The solutions were examined visually for haze, precipitate formation, color change, and evolution of gas immediately after mixing and at 0.25, 1, 3, 8, 24, and 48 hours. Spectrophotometry and thin-layer chromatography were used to test for drug decomposition or chemical incompatibilities. All test methods used showed that no significant degradation of verapamil hydrochloride had taken place in the solutions or through contact with the containers. Slightly higher spectrophotometric readings for dextrose-containing solutions, though within experimental error, could have indicated the presence of dextrose degradation products. Evidence from this study suggests that verapamil hydrocholoride is compatible with the large-volume parenterals studied.

  4. Soft SUSY breaking parameters and RG running of squark and slepton masses in large volume Swiss Cheese compactifications

    International Nuclear Information System (INIS)

    Misra, Aalok; Shukla, Pramod

    2010-01-01

    We consider type IIB large volume compactifications involving orientifolds of the Swiss Cheese Calabi-Yau WCP 4 [1,1,1,6,9] with a single mobile space-time filling D3-brane and stacks of D7-branes wrapping the 'big' divisor Σ B (as opposed to the 'small' divisor usually done in the literature thus far) as well as supporting D7-brane fluxes. After reviewing our proposal of (Misra and Shukla, 2010) for resolving a long-standing tension between large volume cosmology and phenomenology pertaining to obtaining a 10 12 GeV gravitino in the inflationary era and a TeV gravitino in the present era, and summarizing our results of (Misra and Shukla, 2010) on soft supersymmetry breaking terms and open-string moduli masses, we discuss the one-loop RG running of the squark and slepton masses in mSUGRA-like models (using the running of the gaugino masses) to the EW scale in the large volume limit. Phenomenological constraints and some of the calculated soft SUSY parameters identify the D7-brane Wilson line moduli as the first two generations/families of squarks and sleptons and the D3-brane (restricted to the big divisor) position moduli as the two Higgses for MSSM-like models at TeV scale. We also discuss how the obtained open-string/matter moduli make it easier to impose FCNC constraints, as well as RG flow of off-diagonal squark mass(-squared) matrix elements.

  5. A Control Volume Model of Solute Transport in a Single Fracture

    Science.gov (United States)

    Kennedy, Christopher A.; Lennox, William C.

    1995-02-01

    A control volume model of solute transport through a single fracture in a porous matrix is developed. Application to problems of contaminant transport through fractured clay demonstrates several strong features of the method. The control volume approach inherently conserves mass and treats dispersivity at interfaces in a physically correct manner. By employing an upstream weighting scheme, based on the exact solution to the one-dimensional steady state advection-dispersion equation, the model proves to be more efficient than previous single-fracture models. The significance of matrix diffusion in the direction parallel to the fracture axis is investigated. For the transport of a nonreactive tracer through a 20-micrometer-wide fracture in clay material, analytical solutions based on one-dimensional matrix diffusion are erroneous for flow velocities of less than 1 m/day. The influence of boundary conditions on two-dimensional matrix diffusion is considered, and the clean-up of a contaminated fracture is simulated.

  6. Single Crystal Piezoelectric Deformable Mirrors with High Actuator Density and Large Stroke, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Single crystal piezoelectric deformable mirrors with high actuator density, fine pitch, large stroke and no floating wires will be developed for future NASA science...

  7. Single Crystal Piezomotor for Large Stroke, High Precision and Cryogenic Actuations, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — TRS Technologies proposes a novel single crystal piezomotor for large stroke, high precision, and cryogenic actuations with capability of position set-hold with...

  8. Efficient Storage of Large Volume Spatial and Temporal Point-Data in an Object-Oriented Database

    National Research Council Canada - National Science Library

    Oliver, David

    2002-01-01

    Data mining applications must deal with large volumes of data. In particular, Spatio-Temporal Information Systems must efficiently store and access potentially very large quantities of spatial and temporal data...

  9. Single sweep three-dimensional carotid ultrasound: reproducibility in plaque and artery volume measurements.

    Science.gov (United States)

    Kalashyan, Hayrapet; Shuaib, Ashfaq; Gibson, Patrick H; Romanchuk, Helen; Saqqur, Maher; Khan, Khurshid; Osborne, Jonathon; Becher, Harald

    2014-02-01

    There is a need for non-invasive and accurate techniques for assessment of severity of atherosclerotic disease in the carotid arteries. Recently an automated single sweep three-dimensional ultrasound (3D US) technique became available. The aims of this study were to evaluate the feasibility and reproducibility of the automated single sweep method in a cohort of patients undergoing clinically indicated carotid ultrasound. Consecutive patients with a history of stroke or transient ischemic attack (TIA) and having a plaque in the internal carotid artery (ICA) were recruited for this study. Imaging was performed using a Philips iU 22 ultrasound system equipped with the single sweep volumetric transducer vL 13-5. Analysis was performed offline with software provided by the manufacturer. Two independent observers performed all measurements. Of 137 arteries studied (from 79 patients), plaque and artery volumes could be measured in 106 (77%). Reproducibility of plaque volume measurements was assessed in 82 arteries. Bland-Altman analysis demonstrated good inter-observer reproducibility with limits of agreement -0.06 to +0.07 ml. The mean percentage difference between two observers was 5.6% ± 6.0%. Reproducibility of artery volume measurement was assessed in 31 cases. Bland-Altman analysis demonstrated limits of agreement from -0.15 to +0.15 ml. The mean percentage difference was 6.4 ± 5.9%. The new automated single sweep 3D ultrasound is feasible in the majority of patients. Good reproducibility in plaque and artery volume measurements makes this technique suitable for serial assessment of carotid plaques. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  10. State-of-the-Art in GPU-Based Large-Scale Volume Visualization

    KAUST Repository

    Beyer, Johanna

    2015-05-01

    This survey gives an overview of the current state of the art in GPU techniques for interactive large-scale volume visualization. Modern techniques in this field have brought about a sea change in how interactive visualization and analysis of giga-, tera- and petabytes of volume data can be enabled on GPUs. In addition to combining the parallel processing power of GPUs with out-of-core methods and data streaming, a major enabler for interactivity is making both the computational and the visualization effort proportional to the amount and resolution of data that is actually visible on screen, i.e. \\'output-sensitive\\' algorithms and system designs. This leads to recent output-sensitive approaches that are \\'ray-guided\\', \\'visualization-driven\\' or \\'display-aware\\'. In this survey, we focus on these characteristics and propose a new categorization of GPU-based large-scale volume visualization techniques based on the notions of actual output-resolution visibility and the current working set of volume bricks-the current subset of data that is minimally required to produce an output image of the desired display resolution. Furthermore, we discuss the differences and similarities of different rendering and data traversal strategies in volume rendering by putting them into a common context-the notion of address translation. For our purposes here, we view parallel (distributed) visualization using clusters as an orthogonal set of techniques that we do not discuss in detail but that can be used in conjunction with what we present in this survey. © 2015 The Eurographics Association and John Wiley & Sons Ltd.

  11. Two-stage single-volume exchange transfusion in severe hemolytic disease of the newborn.

    Science.gov (United States)

    Abbas, Wael; Attia, Nayera I; Hassanein, Sahar M A

    2012-07-01

    Evaluation of two-stage single-volume exchange transfusion (TSSV-ET) in decreasing the post-exchange rebound increase in serum bilirubin level, with subsequent reduction of the need for repeated exchange transfusions. The study included 104 neonates with hyperbilirubinemia needing exchange transfusion. They were randomly enrolled into two equal groups, each group comprised 52 neonates. TSSV-ET was performed for the 52 neonates and the traditional single-stage double-volume exchange transfusion (SSDV-ET) was performed to 52 neonates. TSSV-ET significantly lowered rebound serum bilirubin level (12.7 ± 1.1 mg/dL), compared to SSDV-ET (17.3 ± 1.7 mg/dL), p < 0.001. Need for repeated exchange transfusions was significantly lower in TSSV-ET group (13.5%), compared to 32.7% in SSDV-ET group, p < 0.05. No significant difference was found between the two groups as regards the morbidity (11.5% and 9.6%, respectively) and the mortality (1.9% for both groups). Two-stage single-volume exchange transfusion proved to be more effective in reducing rebound serum bilirubin level post-exchange and in decreasing the need for repeated exchange transfusions.

  12. 21 CFR 201.323 - Aluminum in large and small volume parenterals used in total parenteral nutrition.

    Science.gov (United States)

    2010-04-01

    ... accumulate aluminum at levels associated with central nervous system and bone toxicity. Tissue loading may... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Aluminum in large and small volume parenterals... for Specific Drug Products § 201.323 Aluminum in large and small volume parenterals used in total...

  13. Enhanced FIB-SEM systems for large-volume 3D imaging

    Science.gov (United States)

    Xu, C Shan; Hayworth, Kenneth J; Lu, Zhiyuan; Grob, Patricia; Hassan, Ahmed M; García-Cerdán, José G; Niyogi, Krishna K; Nogales, Eva; Weinberg, Richard J; Hess, Harald F

    2017-01-01

    Focused Ion Beam Scanning Electron Microscopy (FIB-SEM) can automatically generate 3D images with superior z-axis resolution, yielding data that needs minimal image registration and related post-processing. Obstacles blocking wider adoption of FIB-SEM include slow imaging speed and lack of long-term system stability, which caps the maximum possible acquisition volume. Here, we present techniques that accelerate image acquisition while greatly improving FIB-SEM reliability, allowing the system to operate for months and generating continuously imaged volumes > 106 µm3. These volumes are large enough for connectomics, where the excellent z resolution can help in tracing of small neuronal processes and accelerate the tedious and time-consuming human proofreading effort. Even higher resolution can be achieved on smaller volumes. We present example data sets from mammalian neural tissue, Drosophila brain, and Chlamydomonas reinhardtii to illustrate the power of this novel high-resolution technique to address questions in both connectomics and cell biology. DOI: http://dx.doi.org/10.7554/eLife.25916.001 PMID:28500755

  14. Large-N volume independence in conformal and confining gauge theories

    Energy Technology Data Exchange (ETDEWEB)

    Unsal, Mithat; /SLAC; Yaffe, Laurence G.; /Washington U., Seattle

    2010-08-26

    Consequences of large N volume independence are examined in conformal and confining gauge theories. In the large N limit, gauge theories compactified on R{sup d-k} x (S{sup 1}){sup k} are independent of the S{sup 1} radii, provided the theory has unbroken center symmetry. In particular, this implies that a large N gauge theory which, on R{sup d}, flows to an IR fixed point, retains the infinite correlation length and other scale invariant properties of the decompactified theory even when compactified on R{sup d-k} x (S{sup 1}){sup k}. In other words, finite volume effects are 1/N suppressed. In lattice formulations of vector-like theories, this implies that numerical studies to determine the boundary between confined and conformal phases may be performed on one-site lattice models. In N = 4 supersymmetric Yang-Mills theory, the center symmetry realization is a matter of choice: the theory on R{sup 4-k} x (S{sup 1}){sup k} has a moduli space which contains points with all possible realizations of center symmetry. Large N QCD with massive adjoint fermions and one or two compactified dimensions has a rich phase structure with an infinite number of phase transitions coalescing in the zero radius limit.

  15. A self-sampling method to obtain large volumes of undiluted cervicovaginal secretions.

    Science.gov (United States)

    Boskey, Elizabeth R; Moench, Thomas R; Hees, Paul S; Cone, Richard A

    2003-02-01

    Studies of vaginal physiology and pathophysiology sometime require larger volumes of undiluted cervicovaginal secretions than can be obtained by current methods. A convenient method for self-sampling these secretions outside a clinical setting can facilitate such studies of reproductive health. The goal was to develop a vaginal self-sampling method for collecting large volumes of undiluted cervicovaginal secretions. A menstrual collection device (the Instead cup) was inserted briefly into the vagina to collect secretions that were then retrieved from the cup by centrifugation in a 50-ml conical tube. All 16 women asked to perform this procedure found it feasible and acceptable. Among 27 samples, an average of 0.5 g of secretions (range, 0.1-1.5 g) was collected. This is a rapid and convenient self-sampling method for obtaining relatively large volumes of undiluted cervicovaginal secretions. It should prove suitable for a wide range of assays, including those involving sexually transmitted diseases, microbicides, vaginal physiology, immunology, and pathophysiology.

  16. Very Large Area/Volume Microwave ECR Plasma and Ion Source

    Science.gov (United States)

    Foster, John E. (Inventor); Patterson, Michael J. (Inventor)

    2009-01-01

    The present invention is an apparatus and method for producing very large area and large volume plasmas. The invention utilizes electron cyclotron resonances in conjunction with permanent magnets to produce dense, uniform plasmas for long life ion thruster applications or for plasma processing applications such as etching, deposition, ion milling and ion implantation. The large area source is at least five times larger than the 12-inch wafers being processed to date. Its rectangular shape makes it easier to accommodate to materials processing than sources that are circular in shape. The source itself represents the largest ECR ion source built to date. It is electrodeless and does not utilize electromagnets to generate the ECR magnetic circuit, nor does it make use of windows.

  17. The use of digital volume tomography in imaging an unusually large composite odontoma in the mandible.

    Science.gov (United States)

    Bhatavadekar, Neel B; Bouquot, Jerry E

    2009-01-01

    The odontoma is the most common of all odontogenic tumors. Digital volume tomography (DVT) provides a major advantage of decreased radiation and cost-effectiveness, as compared to a conventional computed tomography. There is no known published report utilizing this DVT analysis for assessing and localizing on odontomo. The purpose of this case report was to document the use of digital volume tomography to assess an unusually large composite odontoma in the mondible. Tomographic sections revealed expansion of the buccol cortex and occasional thinning of both the buccol and lingual cortical plates, although there was no pronounced clinically detectable cortical expansion. The sections further demonstrated enomel ond dentin in on irregular mass bearing no morphologic similority to rudimentary teeth. This case highlights the importance of early diagnosis and intervention for treating on odontoma while demonstrating the value of tomographic imaging as on aid to diagnosis.

  18. Optimal hypofractionated conformal radiotherapy for large brain metastases in patients with high risk factors: a single-institutional prospective study

    International Nuclear Information System (INIS)

    Inoue, Hiroshi K; Sato, Hiro; Suzuki, Yoshiyuki; Saitoh, Jun-ichi; Noda, Shin-ei; Seto, Ken-ichi; Torikai, Kota; Sakurai, Hideyuki; Nakano, Takashi

    2014-01-01

    A single-institutional prospective study of optimal hypofractionated conformal radiotherapy for large brain metastases with high risk factors was performed based on the risk prediction of radiation-related complications. Eighty-eight patients with large brain metastases ≥10 cm 3 in critical areas treated from January 2010 to February 2014 using the CyberKnife were evaluated. The optimal dose and number of fractions were determined based on the surrounding brain volume circumscribed with a single dose equivalent (SDE) of 14 Gy (V14) to be less than 7 cm 3 for individual lesions. Univariate and multivariate analyses were conducted. As a result of optimal treatment, 92 tumors ranging from 10 to 74.6 cm 3 (median, 16.2 cm 3 ) in volume were treated with a median prescribed isodose of 57% and a median fraction number of five. In order to compare the results according to the tumor volume, the tumors were divided into the following three groups: 1) 10–19.9 cm 3 , 2) 20–29.9 cm 3 and 3) ≥30 cm 3 . The lesions were treated with a median prescribed isodose of 57%, 56% and 55%, respectively, and the median fraction number was five in all three groups. However, all tumors ≥20 cm 3 were treated with ≥ five fractions. The median SDE of the maximum dose in the three groups was 47.2 Gy, 48.5 Gy and 46.5 Gy, respectively. Local tumor control was obtained in 90.2% of the patients, and the median survival was nine months, with a median follow-up period of seven months (range, 3-41 months). There were no significant differences in the survival rates among the three groups. Six tumors exhibited marginal recurrence 7-36 months after treatment. Ten patients developed symptomatic brain edema or recurrence of pre-existing edema, seven of whom required osmo-steroid therapy. No patients developed radiation necrosis requiring surgical resection. Our findings demonstrate that the administration of optimal hypofractionated conformal radiotherapy based on the dose-volume prediction

  19. [Peribulbar anesthesia: efficacy of a single injection with a limited local anesthetic volume].

    Science.gov (United States)

    Clausel, H; Touffet, L; Havaux, M; Lamard, M; Savean, J; Cochener, B; Arvieux, C; Gueret, G

    2008-10-01

    Cataract surgery can be performed with peribulbar anesthesia. The classical technique consists of two injections of local anesthetics. The purpose of our study was to assess peribulbar anesthesia with a single injection and a limited volume of local anesthetics. After local ethics committee agreement and oral consent, patients scheduled for cataract surgery using peribulbar anesthesia were prospectively included. The lower temporal puncture was performed with a peribulbar needle with propofol sedation. The mixture of local anesthetics was administered with tactile control of orbital pressure. The puncture was followed by a 10-min compression of the ocular globe. Akinesia, analgesia, complications, and surgical conditions were noted. A total of 101 successive patients were included. We administered 1.2 mg/kg of propofol. The volume of local anesthetics administered was 5.0 +/- 0.9 ml. Ninety patients had akinesia at 10 min and 6.7% moderate chemosis. No puncture complication occurred. At the end of surgery, the pain noted by the patients was 0.4 +/- 2.1 out of 100 (range, 0-10). Surgical conditions were good for all patients. Peribulbar anesthesia performed with a single injection and a limited volume of local anesthetics allows cataract surgery in good conditions for the surgeon with very good analgesia for the patient.

  20. Large-volume liposuction: a review of 631 consecutive cases over 12 years.

    Science.gov (United States)

    Commons, G W; Halperin, B; Chang, C C

    2001-11-01

    Since the advent of epinephrine-containing wetting solutions and sophisticated fluid management techniques, increasingly larger and larger volumes of liposuction aspirations have been reported. Unfortunately, with these larger volumes of liposuction being routinely performed, greater rates of complications have also been reported, with the worst of these resulting in deaths. In a response to the increasing concerns over the safety of large-volume liposuction, a critical review of the senior author's own series has been performed to evaluate risks and benefits and to recommend guidelines for safe and effective large-volume liposuction. A retrospective chart review was performed on 631 consecutive patients who underwent liposuction procedures of at least 3000 cc total aspirate. All procedures were performed by the same senior surgeon between January of 1986 and March of 1998. Before September of 1996, traditional liposuction techniques were used. After September of 1996, ultrasound-assisted liposuction was performed. The superwet technique of fluid management was employed for all procedures performed after 1991. The particulars of the surgical and anesthetic techniques used are reviewed in the article. Data collection included preoperative patient demographics, preoperative and postoperative weights and measurements, and preoperative and postoperative photographs. Total aspirate volumes, fluid intakes, and fluid outputs were measured, and all complications were tallied. Average follow-up was 1 year. Results showed the majority of patients to be women, aged 17 to 74 years old. Of the preoperative weights, 98.7 percent were within 50 pounds of ideal chart weight. Total aspirate volumes ranged from 3 to 17 liters, with 94.5 percent of these under 10 liters. Fluid balance measurements showed an average of 120 cc/kg positive fluid balance at the end of the procedure, with none of these patients experiencing any significant fluid balance abnormalities. Cosmetic results

  1. Visceral adipose tissue area measurement at a single level: can it represent visceral adipose tissue volume?

    Science.gov (United States)

    Noumura, Yusuke; Kamishima, Tamotsu; Sutherland, Kenneth; Nishimura, Hideho

    2017-08-01

    Measurement of visceral adipose tissue (VAT) needs to be accurate and sensitive to change for risk monitoring. The purpose of this study is to determine the CT slice location where VAT area can best reflect changes in VAT volume and body weight. 60 plain abdominal CT images from 30 males [mean age (range) 51 (41-68) years, mean body weight (range) 71.1 (101.9-50.9) kg] who underwent workplace screenings twice within a 1-year interval were evaluated. Automatically calculated and manually corrected areas of the VAT of various scan levels using "freeform curve" region of interest on CT were recorded and compared with body weight changes. The strongest correlations of VAT area with VAT volume and body weight changes were shown in a slice 3 cm above the lower margin of L3 with r values of 0.853 and 0.902, respectively. VAT area measurement at a single level 3 cm above the lower margin of the L3 vertebra is feasible and can reflect changes in VAT volume and body weight. Advances in knowledge: As VAT area at a CT slice 3cm above the lower margin of L3 can best reflect interval changes in VAT volume and body weight, VAT area measurement should be selected at this location.

  2. Fan-beam scanning laser optical computed tomography for large volume dosimetry

    Science.gov (United States)

    Dekker, K. H.; Battista, J. J.; Jordan, K. J.

    2017-05-01

    A prototype scanning-laser fan beam optical CT scanner is reported which is capable of high resolution, large volume dosimetry with reasonable scan time. An acylindrical, asymmetric aquarium design is presented which serves to 1) generate parallel-beam scan geometry, 2) focus light towards a small acceptance angle detector, and 3) avoid interference fringe-related artifacts. Preliminary experiments with uniform solution phantoms (11 and 15 cm diameter) and finger phantoms (13.5 mm diameter FEP tubing) demonstrate that the design allows accurate optical CT imaging, with optical CT measurements agreeing within 3% of independent Beer-Lambert law calculations.

  3. GMP cryopreservation of large volumes of cells for regenerative medicine: active control of the freezing process.

    Science.gov (United States)

    Massie, Isobel; Selden, Clare; Hodgson, Humphrey; Fuller, Barry; Gibbons, Stephanie; Morris, G John

    2014-09-01

    Cryopreservation protocols are increasingly required in regenerative medicine applications but must deliver functional products at clinical scale and comply with Good Manufacturing Process (GMP). While GMP cryopreservation is achievable on a small scale using a Stirling cryocooler-based controlled rate freezer (CRF) (EF600), successful large-scale GMP cryopreservation is more challenging due to heat transfer issues and control of ice nucleation, both complex events that impact success. We have developed a large-scale cryocooler-based CRF (VIA Freeze) that can process larger volumes and have evaluated it using alginate-encapsulated liver cell (HepG2) spheroids (ELS). It is anticipated that ELS will comprise the cellular component of a bioartificial liver and will be required in volumes of ∼2 L for clinical use. Sample temperatures and Stirling cryocooler power consumption was recorded throughout cooling runs for both small (500 μL) and large (200 mL) volume samples. ELS recoveries were assessed using viability (FDA/PI staining with image analysis), cell number (nuclei count), and function (protein secretion), along with cryoscanning electron microscopy and freeze substitution techniques to identify possible injury mechanisms. Slow cooling profiles were successfully applied to samples in both the EF600 and the VIA Freeze, and a number of cooling and warming profiles were evaluated. An optimized cooling protocol with a nonlinear cooling profile from ice nucleation to -60°C was implemented in both the EF600 and VIA Freeze. In the VIA Freeze the nucleation of ice is detected by the control software, allowing both noninvasive detection of the nucleation event for quality control purposes and the potential to modify the cooling profile following ice nucleation in an active manner. When processing 200 mL of ELS in the VIA Freeze-viabilities at 93.4% ± 7.4%, viable cell numbers at 14.3 ± 1.7 million nuclei/mL alginate, and protein secretion at 10.5 ± 1.7

  4. Characteristics of the NE-213 large-volume neutron counters for muon catalyzed fusion investigation

    International Nuclear Information System (INIS)

    Bystritsky, V.M.; Wozniak, J.; Zinov, V.G.

    1984-01-01

    The Monte-Carlo method was used to establish the properties and feasibility of a large-volume NE-213 scin illator as an efficient neutron detector. The recoil proton spectra, calculated efficiencies for different detection thresholds and scintillator sizes are presented for the neutron energy up to 15 MeV. The time characteristics, e. g., time resolution, are discussed. It is also shown that no strong influence of light attenuation by the scintilla or itself on calculated efficiencies is observed, when gamma-calibration technique is used. The detector vol me of approximately 100 l is suggested for application in investigations of μ-atom and μ-molecular processes

  5. Open loop control of filament heating power supply for large volume plasma device

    International Nuclear Information System (INIS)

    Sugandhi, R.; Srivastava, P.K.; Sanyasi, A.K.; Srivastav, Prabhakar; Awasthi, L.M.; Mattoo, S.K.

    2017-01-01

    A power supply (20 V, 10 kA) for powering the filamentary cathode has been procured, interfaced and integrated with the centralized control system of Large Volume Plasma Device (LVPD). Software interface has been developed on the standard Modbus RTU communication protocol. It facilitates the dashboard for configuration, on line status monitoring, alarm management, data acquisition, synchronization and controls. It has been tested for stable operation of the power supply for the operational capabilities. The paper highlights the motivation, interface description, implementation and results obtained.

  6. Biphasic defibrillation using a single capacitor with large capacitance: reduction of peak voltages and ICD device size.

    Science.gov (United States)

    Block, M; Hammel, D; Böcker, D; Borggrefe, M; Budde, T; Isbruch, F; Scheld, H H; Breithardt, G

    1996-02-01

    The volume of current implantable cardioverter defibrillators (ICD) is not convenient for pectoral implantation. One way to reduce the size of the pulse generator is to find a more effective defibrillation pulse waveform generated from smaller volume capacitors. In a prospective randomized crossover study we compared the step-down defibrillation threshold (DFT) of a standard biphasic waveform (STD), delivered by two 250-microF capacitors connected in series with an 80% tilt, to an experimental biphasic waveform delivered by a single 450-microF capacitor with a 60% tilt. The experimental waveform delivered the same energy with a lower peak voltage and a longer duration (LVLD). Intraoperatively, in 25 patients receiving endocardial (n = 12) or endocardial-subcutaneous array (n = 13) defibrillation leads, the DFT was determined for both waveforms. Energy requirements did not differ at DFT for the STD and LVLD waveforms with the low impedance (32 +/- 4 omega) endocardial-subcutaneous array defibrillation lead system (6.4 +/- 4.4 J and 5.9 +/- 4.2 J, respectively) or increased slightly (P = 0.06) with the higher impedance (42 +/- 4 omega) endocardial lead system (10.4 +/- 4.6 J and 12.7 +/- 5.7 J, respectively). However, the voltage needed at DFT was one-third lower with the LVLD waveform than with the STD waveform for both lead systems (256 +/- 85 V vs 154 +/- 51 V and 348 +/- 76 V vs 232 +/- 54 V, respectively). Thus, a single capacitor with a large capacitance can generate a defibrillation pulse with a substantial lower peak voltage requirement without significantly increasing the energy requirements. The volume reduction in using a single capacitor can decrease ICD device size.

  7. Volume reflection and channeling of ultrarelativistic protons in germanium bent single crystals

    Directory of Open Access Journals (Sweden)

    S. Bellucci

    2016-12-01

    Full Text Available The paper is devoted to the investigation of volume reflection and channeling processes of ultrarelativistic positive charged particles moving in germanium single crystals. We demonstrate that the choice of atomic potential on the basis of the Hartree-Fock method and the correct choice of the Debye temperature allow us to describe the above mentioned processes in a good agreement with the recent experiments. Moreover, the universal form of equations for volume reflection presented in the paper gives a true description of the process at a wide range of particle energies. Standing on this study we make predictions for the mean angle reflection (as a function of the bending radius of positive and negative particles for germanium (110 and (111 crystallographic planes.

  8. Stability, tunneling and flux changing de Sitter transitions in the large volume string scenario

    Science.gov (United States)

    de Alwis, S.; Gupta, R.; Hatefi, E.; Quevedo, F.

    2013-11-01

    We study the non-perturbative stability of the Large Volume Scenario (LVS) of IIB string compactifications, by analysing transitions mediated by the Brown-Teitelboim (BT) brane nucleations and by Coleman De Luccia tunneling (CDL). We find that, as long as the effective field theory description holds, the LVS AdS minima are stable despite being non-supersymmetric. This opens the possibility of having a CFT dual. Metastable de Sitter vacua behave differently depending on the uplifting mechanism. We find explicit expressions for the different decay rates in terms of exponentials of the volume. Among the transitions of dS to dS those with increasing volume and decreasing vacuum energy are preferred, though dS decays to AdS (big-crunch sinks) have higher probability. Transitions via the CDL mechanism to decompactification are exponentially suppressed compared to these. The BT decays correspond to flux/D3 brane transitions mediated by the nucleation of D5/NS5 branes. We compare our results with previous analysis for KKLT, type IIA, and 6D Einstein-Maxwell studies. In particular we find no indication for a bubble of nothing decay.

  9. A scale down process for the development of large volume cryopreservation.

    Science.gov (United States)

    Kilbride, Peter; Morris, G John; Milne, Stuart; Fuller, Barry; Skepper, Jeremy; Selden, Clare

    2014-12-01

    The process of ice formation and propagation during cryopreservation impacts on the post-thaw outcome for a sample. Two processes, either network solidification or progressive solidification, can dominate the water-ice phase transition with network solidification typically present in small sample cryo-straws or cryo-vials. Progressive solidification is more often observed in larger volumes or environmental freezing. These different ice phase progressions could have a significant impact on cryopreservation in scale-up and larger volume cryo-banking protocols necessitating their study when considering cell therapy applications. This study determines the impact of these different processes on alginate encapsulated liver spheroids (ELS) as a model system during cryopreservation, and develops a method to replicate these differences in an economical manner. It was found in the current studies that progressive solidification resulted in fewer, but proportionally more viable cells 24h post-thaw compared with network solidification. The differences between the groups diminished at later time points post-thaw as cells recovered the ability to undertake cell division, with no statistically significant differences seen by either 48 h or 72 h in recovery cultures. Thus progressive solidification itself should not prove a significant hurdle in the search for successful cryopreservation in large volumes. However, some small but significant differences were noted in total viable cell recoveries and functional assessments between samples cooled with either progressive or network solidification, and these require further investigation. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Technical design and commissioning of the KATRIN large-volume air coil system

    Science.gov (United States)

    Erhard, M.; Behrens, J.; Bauer, S.; Beglarian, A.; Berendes, R.; Drexlin, G.; Glück, F.; Gumbsheimer, R.; Hergenhan, J.; Leiber, B.; Mertens, S.; Osipowicz, A.; Plischke, P.; Reich, J.; Thümmler, T.; Wandkowsky, N.; Weinheimer, C.; Wüstling, S.

    2018-02-01

    The KATRIN experiment is a next-generation direct neutrino mass experiment with a sensitivity of 0.2 eV (90% C.L.) to the effective mass of the electron neutrino. It measures the tritium β-decay spectrum close to its endpoint with a spectrometer based on the MAC-E filter technique. The β-decay electrons are guided by a magnetic field that operates in the mT range in the central spectrometer volume; it is fine-tuned by a large-volume air coil system surrounding the spectrometer vessel. The purpose of the system is to provide optimal transmission properties for signal electrons and to achieve efficient magnetic shielding against background. In this paper we describe the technical design of the air coil system, including its mechanical and electrical properties. We outline the importance of its versatile operation modes in background investigation and suppression techniques. We compare magnetic field measurements in the inner spectrometer volume during system commissioning with corresponding simulations, which allows to verify the system's functionality in fine-tuning the magnetic field configuration. This is of major importance for a successful neutrino mass measurement at KATRIN.

  11. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy.

    Science.gov (United States)

    Burnett, T L; Kelley, R; Winiarski, B; Contreras, L; Daly, M; Gholinia, A; Burke, M G; Withers, P J

    2016-02-01

    Ga(+) Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga(+) FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe(+) Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC-Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (WC-Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60nA at 30kV. Xe(+) PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  12. Hybrid Parallelism for Volume Rendering on Large-, Multi-, and Many-Core Systems

    Energy Technology Data Exchange (ETDEWEB)

    Howison, Mark [Brown Univ., Providence, RI (United States); Bethel, E. Wes [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Childs, Hank [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-01-01

    With the computing industry trending towards multi- and many-core processors, we study how a standard visualization algorithm, ray-casting volume rendering, can benefit from a hybrid parallelism approach. Hybrid parallelism provides the best of both worlds: using distributed-memory parallelism across a large numbers of nodes increases available FLOPs and memory, while exploiting shared-memory parallelism among the cores within each node ensures that each node performs its portion of the larger calculation as efficiently as possible. We demonstrate results from weak and strong scaling studies, at levels of concurrency ranging up to 216,000, and with datasets as large as 12.2 trillion cells. The greatest benefit from hybrid parallelism lies in the communication portion of the algorithm, the dominant cost at higher levels of concurrency. We show that reducing the number of participants with a hybrid approach significantly improves performance.

  13. MPI-hybrid Parallelism for Volume Rendering on Large, Multi-core Systems

    Energy Technology Data Exchange (ETDEWEB)

    Howison, Mark; Bethel, E. Wes; Childs, Hank

    2010-03-20

    This work studies the performance and scalability characteristics of"hybrid'" parallel programming and execution as applied to raycasting volume rendering -- a staple visualization algorithm -- on a large, multi-core platform. Historically, the Message Passing Interface (MPI) has become the de-facto standard for parallel programming and execution on modern parallel systems. As the computing industry trends towards multi-core processors, with four- and six-core chips common today and 128-core chips coming soon, we wish to better understand how algorithmic and parallel programming choices impact performance and scalability on large, distributed-memory multi-core systems. Our findings indicate that the hybrid-parallel implementation, at levels of concurrency ranging from 1,728 to 216,000, performs better, uses a smaller absolute memory footprint, and consumes less communication bandwidth than the traditional, MPI-only implementation.

  14. Onco plastic volume replacement with latissimus dorsi myocutaneous flap in patients with large ptotic breasts. Is it feasible?

    International Nuclear Information System (INIS)

    El-Marakby, H.H.; Kotb, M.H.

    2011-01-01

    Onco plastic breast conservative surgery has evolved as a safe alternative to the standard mastectomy in the treatment of early breast cancer. The procedure involves tumour resection with an adequate safety margin and either breast reshaping with volume displacement procedures (large or pt otic breasts) or volume replacement with latissimus dorsi myocutaneous flap (LDF) (small to medium sized non-ptotic breasts). A contra lateral mastopexy procedure is usually necessary with the volume displacement Onco plastic surgery, a procedure that is often rejected by a significant number of patients. This limits the choice of the reconstruction of breast defects in such patients to autologous tissues i.e. LDF. Aim: Aim is to evaluate the feasibility of volume replacement onco plastic breast conservative surgery with lemmatise dorsi myocutaneous flaps for patients with large ptotic breasts. This involves testing the oncologic safety in terms of adequate safety margin, the complications rate and the final cosmetic outcome. The loco regional recurrence rate will be recorded and compared with oncoplastic volume displacement for similar sized breast defects. Patients and methods: A group of 50 female patients with early breast cancers (T2) who presented to the department of surgery at the National Cancer Institute, Cairo, Egypt in the period between carried out in all patient groups and was used to annually follow up the patients. All patients were detected with T2 NO breast cancer by both clinical and radiological examinations. All patients underwent partial mastectomy was and reconstruction with LDFs. Results: The average age at presentation was 46.5 ± 9 years and the range was 26-65 years. Most of the patients were subjected to partial mastectomy in 30 patients (60%), excision of a single quadrant from the four major quadrants was carried out in 15 patients (30%) where skin sparing wide local excision was carried out in only five patients (10%). The safety margin ranged from

  15. SDSS Log Viewer: visual exploratory analysis of large-volume SQL log data

    Science.gov (United States)

    Zhang, Jian; Chen, Chaomei; Vogeley, Michael S.; Pan, Danny; Thakar, Ani; Raddick, Jordan

    2012-01-01

    User-generated Structured Query Language (SQL) queries are a rich source of information for database analysts, information scientists, and the end users of databases. In this study a group of scientists in astronomy and computer and information scientists work together to analyze a large volume of SQL log data generated by users of the Sloan Digital Sky Survey (SDSS) data archive in order to better understand users' data seeking behavior. While statistical analysis of such logs is useful at aggregated levels, efficiently exploring specific patterns of queries is often a challenging task due to the typically large volume of the data, multivariate features, and data requirements specified in SQL queries. To enable and facilitate effective and efficient exploration of the SDSS log data, we designed an interactive visualization tool, called the SDSS Log Viewer, which integrates time series visualization, text visualization, and dynamic query techniques. We describe two analysis scenarios of visual exploration of SDSS log data, including understanding unusually high daily query traffic and modeling the types of data seeking behaviors of massive query generators. The two scenarios demonstrate that the SDSS Log Viewer provides a novel and potentially valuable approach to support these targeted tasks.

  16. A retrospective analysis of complications of large volume liposuction; local perspective from a third world country

    International Nuclear Information System (INIS)

    Arshad, S.M.; Latif, S.; Altaf, H.N.

    2017-01-01

    This study was aimed at evaluating the complications that occurred in patients undergoing large volume liposuction and to see if there was a correlation between amount of aspirate and the rate of complications. Methodology: A detailed history, complete physical examination, BMI, and anthropometric measurements were documented for all patients. All patients under went liposuction using tumescent technique under general anesthesia in Yusra General Hospital. Patients were discharged home after 24 to 48 hours. Pressure garments were advised for 6 weeks and were called for weekly follow up for 6 weeks. Pressure garments were advised for 6 weeks. Complications were documented. SPSS version 20 was used for analysis of data. Results: Out of 217 patients, 163 (75%) were female and 54 male. Mean age was 37.1 SD+-6.7 years. Bruising and seroma were most common complications; 4.1% and 2.3%, respectively. The incidence of infection was 0.9%. One patient had over-correction and four patients (1.8%) had under-correction. Significant blood loss was encountered in one patient. Two patients (0.9%) had pulmonary embolism and 2(0.9%) suffered from necrotizing fasciitis. None of our patients undergoing large volume liposuction had fat embolism and there was no mortality. Conclusion: Careful patient selection and strict adherence to guidelines can ensure a good outcome and can minimize risk of complications. Both physicians and patients should be educated to have realistic expectations to avoid complications and improve patient safety. (author)

  17. Gradient ROtating Outer Volume Excitation (GROOVE): A Novel Method for Single-Shot 2-D OVS

    Science.gov (United States)

    Powell, Nathaniel J.; Jang, Albert; Park, Jang-Yeon; Valette, Julien; Garwood, Michael; Marjańska, Małgorzata

    2014-01-01

    Purpose A new outer volume suppression (OVS) technique is introduced that uses a single pulse and rotating gradients to accomplish frequency-swept excitation. This new technique, which is called Gradient ROtating Outer Volume Excitation (GROOVE), produces a circular or elliptical suppression band rather than suppressing the entire outer volume. Methods Theoretical and k-space descriptions of GROOVE are provided. The properties of GROOVE were investigated with simulations, phantom, and human experiments performed using a 4 T horizontal bore magnet equipped with a TEM coil. Results Similar suppression performance was obtained in phantom and human brain using GROOVE with circular and elliptical shapes. Simulations indicate that GROOVE requires less SAR and time than traditional OVS schemes, but traditional schemes provide a sharper transition zone and less residual signal. Conclusion GROOVE represents a new way of performing OVS in which spins are excited temporally in space on a trajectory which can be tailored to fit the shape of the suppression region. In addition, GROOVE is capable of suppressing tailored regions of space with more flexibility and in a shorter period of time than conventional methods. GROOVE provides a fast, low SAR alternative to conventional OVS methods in some applications (e.g., scalp suppression). PMID:24478130

  18. System of large transport containers for waste from dismantling light water and gas-cooled nuclear reactors. Volume 2

    International Nuclear Information System (INIS)

    Price, M.S.T.; Lafontaine, I.

    1985-01-01

    The purpose of this volume is to assess the means of transportation of decommissioning wastes, costs of transport, radiological detriment attributable to transport and develops conceptual designs of large transport containers. The document ends with Conclusions and Recommendations

  19. Advances in Large Grain/Single Crystal SC Resonators at DESY

    International Nuclear Information System (INIS)

    W. Singer; A. Brinkmann; A. Ermakov; J. Iversen; G. Kreps; A. Matheisen; D. Proch; D. Reschke; X. Singer; M. Spiwek; H. We; P. Kneisel; M. Pekeler

    2007-01-01

    The main aim of the DESY large grain R and D program is to check whether this option is reasonable to apply for fabrication of ca. 1000 XFEL cavities. Two aspects are being pursued. On one hand the basic material investigation, on the other hand the material availability, fabrication and preparation procedure. Several single cell large grain cavities of TESLA shape have been fabricated and tested. The best accelerating gradients of 41 MV/m was measured on electropolished cavity. First large grain nine-cell cavities worldwide have been produced under contract of DESY with ACCEL Instruments Co. All three cavities fulfill the XFEL specification already in first RF test after only BCP (Buffered Chemical Polishing) treatment and 800 degrees C annealing. Accelerating gradient of 27-29 MV/m was reached. A fabrication method of single crystal cavity of ILC like shape was proposed. A single cell single crystal cavity was build at the company ACCEL. Accelerating gradient of 37.5 MV/m reached after only 112 microns BCP and in situ baking 120 degrees C for 6 hrs with the quality factor higher as 2x1010. The developed method can be extended on fabrication of multi cell single crystal cavities

  20. Lupus-related single nucleotide polymorphisms and risk of diffuse large B-cell lymphoma

    NARCIS (Netherlands)

    Bernatsky, Sasha; Velásquez García, Héctor A; Spinelli, John; Gaffney, Patrick; Smedby, Karin E; Ramsey-Goldman, Rosalind; Wang, Sophia S.; Adami, Hans-Olov; Albanes, Demetrius; Angelucci, Emanuele; Ansell, Stephen M.; Asmann, Yan W.; Becker, Nikolaus; Benavente, Yolanda; Berndt, Sonja I.; Bertrand, Kimberly A.; Birmann, Brenda M.; Boeing, Heiner; Boffetta, Paolo; Bracci, Paige M.; Brennan, Paul; Brooks-Wilson, Angela R.; Cerhan, James R.; Chanock, Stephen J.; Clavel, Jacqueline; Conde, Lucia; Cotenbader, Karen H; Cox, David G; Cozen, Wendy; Crouch, Simon; De Roos, Anneclaire J.; De Sanjose, Silvia; Di Lollo, Simonetta; Diver, W. Ryan; Dogan, Ahmet; Foretova, Lenka; Ghesquières, Hervé; Giles, Graham G.; Glimelius, Bengt; Habermann, Thomas M.; Haioun, Corinne; Hartge, Patricia; Hjalgrim, Henrik; Holford, Theodore R.; Holly, Elizabeth A.; Jackson, Rebecca D.; Kaaks, Rudolph; Kane, Eleanor; Kelly, Rachel S.; Klein, Robert J.; Kraft, Peter; Kricker, Anne; Lan, Qing; Lawrence, Charles; Liebow, Mark; Lightfoot, Tracy; Link, Brian K.; Maynadie, Marc; McKay, James; Melbye, Mads; Molina, Thierry Jo; Monnereau, Alain; Morton, Lindsay M.; Nieters, Alexandra; North, Kari E.; Novak, Anne J.; Offit, Kenneth; Purdue, Mark P.; Rais, Marco; Riby, Jacques; Roman, Eve; Rothman, Nathaniel; Salles, Gilles; Severi, Gianluca; Severson, Richard K.; Skibola, Christine F.; Slager, Susan L.; Smith, Alex; Smith, Martyn T.; Southey, Melissa C.; Staines, Anthony; Teras, Lauren R.; Thompson, Carrie A.; Tilly, Hervé; Tinker, Lesley F.; Tjonneland, Anne; Turner, Jenny; Vajdic, Claire M.; Vermeulen, Roel C H; Vijai, Joseph; Vineis, Paolo; Virtamo, Jarmo; Wang, Zhaoming; Weinstein, Stephanie; Witzig, Thomas E.; Zelenetz, Andrew; Zeleniuch-Jacquotte, Anne; Zhang, Yawei; Zheng, Tongzhang; Zucca, Mariagrazia; Clarke, Ann E

    2017-01-01

    Objective: Determinants of the increased risk of diffuse large B-cell lymphoma (DLBCL) in SLE are unclear. Using data from a recent lymphoma genome-wide association study (GWAS), we assessed whether certain lupus-related single nucleotide polymorphisms (SNPs) were also associated with DLBCL.

  1. Recognition of handwritten numerical fields in a large single-writer historical collection

    NARCIS (Netherlands)

    Bulacu, Marius; Brink, Axel; Zant, Tijn Van Der; Schomaker, Lambertus

    2009-01-01

    This paper presents a segmentation-based handwriting recognizer and the performance that it achieves on the numerical fields extracted from a large single-writer historical collection. Our recognizer has the particularity that it uses morphing during training: random elastic deformations are applied

  2. Study on the temperature field of large-sized sapphire single crystal furnace

    Science.gov (United States)

    Zhai, J. P.; Jiang, J. W.; Liu, K. G.; Peng, X. B.; Jian, D. L.; Li, I. L.

    2018-01-01

    In this paper, the temperature field of large-sized (120kg, 200kg and 300kg grade) sapphire single crystal furnace was simulated. By keeping the crucible diameter ratio and the insulation system unchanged, the power consumption, axial and radial temperature gradient, solid-liquid surface shape, stress distribution and melt flow were studied. The simulation results showed that with the increase of the single crystal furnace size, the power consumption increased, the temperature field insulation effect became worse, the growth stress value increased and the stress concentration phenomenon occurred. To solve these problems, the middle and bottom insulation system should be enhanced during designing the large-sized sapphire single crystal furnace. The appropriate radial and axial temperature gradient was favorable to reduce the crystal stress and prevent the occurrence of cracking. Expanding the interface between the seed and crystal was propitious to avoid the stress accumulation phenomenon.

  3. Large Mode Area Single Trench Fiber for 2 mu m Operation

    DEFF Research Database (Denmark)

    Jain, Deepak; Sahu, Jayanta K.

    2016-01-01

    to 25 cm bend radius, respectively, by exploiting high delocalization of the higher order modes. Achievement of a large effective-area can be very useful to address nonlinear effects. Moreover, single trench fiber offers certain advantages such as low-cost fabrication and easy postprocessing (such......Performance of single trench fibers has been investigated using finite-element method at 2 mu m wavelength. Numerical investigations show that an effective single mode operation for large effective area between 3000-4000 mu m(2) and 2000-3000 mu m(2) can be achieved at similar to 40 and similar...... as cleaving and splicing) thanks to the all-solid fiber design....

  4. A large volume cell for in situ neutron diffraction studies of hydrothermal crystallizations

    Science.gov (United States)

    Xia, Fang; Qian, Gujie; Brugger, Joël; Studer, Andrew; Olsen, Scott; Pring, Allan

    2010-10-01

    A hydrothermal cell with 320 ml internal volume has been designed and constructed for in situ neutron diffraction studies of hydrothermal crystallizations. The cell design adopts a dumbbell configuration assembled with standard commercial stainless steel components and a zero-scattering Ti-Zr alloy sample compartment. The fluid movement and heat transfer are simply driven by natural convection due to the natural temperature gradient along the fluid path, so that the temperature at the sample compartment can be stably sustained by heating the fluid in the bottom fluid reservoir. The cell can operate at temperatures up to 300 °C and pressures up to 90 bars and is suitable for studying reactions requiring a large volume of hydrothermal fluid to damp out the negative effect from the change of fluid composition during the course of the reactions. The capability of the cell was demonstrated by a hydrothermal phase transformation investigation from leucite (KAlSi2O6) to analcime (NaAlSi2O6ṡH2O) at 210 °C on the high intensity powder diffractometer Wombat in ANSTO. The kinetics of the transformation has been resolved by collecting diffraction patterns every 10 min followed by Rietveld quantitative phase analysis. The classical Avrami/Arrhenius analysis gives an activation energy of 82.3±1.1 kJ mol-1. Estimations of the reaction rate under natural environments by extrapolations agree well with petrological observations.

  5. A strategy to effectively make use of large volumes of climate data for climate change adaptation

    Directory of Open Access Journals (Sweden)

    Rasmus Benestad

    2017-04-01

    Full Text Available A strategy is suggested for presenting high-resolution temperature maps based on projections from large multi-model ensembles with minimal requirement of data space. This ability to reduce data volumes may be useful for climate services. We present a web-based solution that provides maps with seasonal mean temperatures at 5-min spatial resolution. The maps were generated from downscaled groups of 223 stations from the Barents region, and were based on results from principal component analysis (PCA for which the five leading modes represented most of the variance and enabled the extraction of salient features while significantly reducing the data volume. A demonstration of the concept showed how different aspects can be distilled, such as ensemble means, ensemble member differences, point-wise time series, probabilities, number of hot/cold days, and various quality aspects. The demonstration included three different types of emissions scenarios: the RCPs 2.6, 4.5, and 8.5. This way of organising data is instrumental to extracting relevant information for decision-making, but does not alone imply actionable adaptation information. The question of reliability and robustness depends on the quality of the data rather than the way it is organised.

  6. A large volume uniform plasma generator for the experiments of electromagnetic wave propagation in plasma

    International Nuclear Information System (INIS)

    Yang Min; Li Xiaoping; Xie Kai; Liu Donglin; Liu Yanming

    2013-01-01

    A large volume uniform plasma generator is proposed for the experiments of electromagnetic (EM) wave propagation in plasma, to reproduce a “black out” phenomenon with long duration in an environment of the ordinary laboratory. The plasma generator achieves a controllable approximate uniform plasma in volume of 260 mm× 260 mm× 180 mm without the magnetic confinement. The plasma is produced by the glow discharge, and the special discharge structure is built to bring a steady approximate uniform plasma environment in the electromagnetic wave propagation path without any other barriers. In addition, the electron density and luminosity distributions of plasma under different discharge conditions were diagnosed and experimentally investigated. Both the electron density and the plasma uniformity are directly proportional to the input power and in roughly reverse proportion to the gas pressure in the chamber. Furthermore, the experiments of electromagnetic wave propagation in plasma are conducted in this plasma generator. Blackout phenomena at GPS signal are observed under this system and the measured attenuation curve is of reasonable agreement with the theoretical one, which suggests the effectiveness of the proposed method.

  7. A large volume cell for in situ neutron diffraction studies of hydrothermal crystallizations.

    Science.gov (United States)

    Xia, Fang; Qian, Gujie; Brugger, Joël; Studer, Andrew; Olsen, Scott; Pring, Allan

    2010-10-01

    A hydrothermal cell with 320 ml internal volume has been designed and constructed for in situ neutron diffraction studies of hydrothermal crystallizations. The cell design adopts a dumbbell configuration assembled with standard commercial stainless steel components and a zero-scattering Ti-Zr alloy sample compartment. The fluid movement and heat transfer are simply driven by natural convection due to the natural temperature gradient along the fluid path, so that the temperature at the sample compartment can be stably sustained by heating the fluid in the bottom fluid reservoir. The cell can operate at temperatures up to 300 °C and pressures up to 90 bars and is suitable for studying reactions requiring a large volume of hydrothermal fluid to damp out the negative effect from the change of fluid composition during the course of the reactions. The capability of the cell was demonstrated by a hydrothermal phase transformation investigation from leucite (KAlSi(2)O(6)) to analcime (NaAlSi(2)O(6)⋅H(2)O) at 210 °C on the high intensity powder diffractometer Wombat in ANSTO. The kinetics of the transformation has been resolved by collecting diffraction patterns every 10 min followed by Rietveld quantitative phase analysis. The classical Avrami/Arrhenius analysis gives an activation energy of 82.3±1.1 kJ  mol(-1). Estimations of the reaction rate under natural environments by extrapolations agree well with petrological observations.

  8. Liquid Hole-Multipliers: A potential concept for large single-phase noble-liquid TPCs of rare events

    Science.gov (United States)

    Breskin, Amos

    2013-10-01

    A novel concept is proposed for large-volume single-phase noble-liquid TPC detectors for rare events. Both radiation-induced scintillation-light and ionization-charge are detected by Liquid Hole-Multipliers (LHM), immersed in the noble liquid. The latter may consist of cascaded Gas Electron Multipliers (GEM), Thick Gas Electron Multiplier (THGEM) electrodes or others, coated with CsI UV-photocathodes. Electrons, photo-induced on CsI by primary scintillation in the noble liquid, and event-correlated drifting ionization electrons are amplified in the cascaded elements primarily through electroluminescence, and possibly through additional moderate avalanche, occurring within the holes. The resulting charge-signals or light-pulses are recorded on anode pads or with photosensors - e.g. gaseous photomultipliers (GPM), respectively. Potential affordable solutions are proposed for multi-ton dark-matter detectors; open questions are formulated for validating this dream.

  9. Liquid Hole-Multipliers: A potential concept for large single-phase noble-liquid TPCs of rare events

    International Nuclear Information System (INIS)

    Breskin, Amos

    2013-01-01

    A novel concept is proposed for large-volume single-phase noble-liquid TPC detectors for rare events. Both radiation-induced scintillation-light and ionization-charge are detected by Liquid Hole-Multipliers (LHM), immersed in the noble liquid. The latter may consist of cascaded Gas Electron Multipliers (GEM), Thick Gas Electron Multiplier (THGEM) electrodes or others, coated with CsI UV-photocathodes. Electrons, photo-induced on CsI by primary scintillation in the noble liquid, and event-correlated drifting ionization electrons are amplified in the cascaded elements primarily through electroluminescence, and possibly through additional moderate avalanche, occurring within the holes. The resulting charge-signals or light-pulses are recorded on anode pads or with photosensors – e.g. gaseous photomultipliers (GPM), respectively. Potential affordable solutions are proposed for multi-ton dark-matter detectors; open questions are formulated for validating this dream

  10. The core collapse supernova rate from 24 years of data of the Large Volume Detector

    Science.gov (United States)

    Bruno, G.; Fulgione, W.; Molinario, A.; Vigorito, C.; LVD Collaboration

    2017-09-01

    The Large Volume Detector (LVD) at INFN Laboratori Nazionali del Gran Sasso, Italy is a 1 kt liquid scintillator neutrino observatory mainly designed to study low energy neutrinos from Gravitational Stellar Collapses (GSC) with 100% efficiency over the entire Galaxy. Here we summarize the results of the search for supernova neutrino bursts over the full data set lasting from June 1992 to May 2016 for a total live time of 8211 days. In the lack of a positive observation, either in standalone mode or in coincidence with other experiments, we establish the upper limit to the rate of GSC event in the Milky Way: 0.1 year-1 at 90% c.l..

  11. Rugged Large Volume Injection for Sensitive Capillary LC-MS Environmental Monitoring

    Directory of Open Access Journals (Sweden)

    Hanne Roberg-Larsen

    2017-08-01

    Full Text Available A rugged and high throughput capillary column (cLC LC-MS switching platform using large volume injection and on-line automatic filtration and filter back-flush (AFFL solid phase extraction (SPE for analysis of environmental water samples with minimal sample preparation is presented. Although narrow columns and on-line sample preparation are used in the platform, high ruggedness is achieved e.g., injection of 100 non-filtrated water samples did not result in a pressure rise/clogging of the SPE/capillary columns (inner diameter 300 μm. In addition, satisfactory retention time stability and chromatographic resolution were also features of the system. The potential of the platform for environmental water samples was demonstrated with various pharmaceutical products, which had detection limits (LOD in the 0.05–12.5 ng/L range. Between-day and within-day repeatability of selected analytes were <20% RSD.

  12. Measurement of the velocity of neutrinos from the CNGS beam with the large volume detector.

    Science.gov (United States)

    Agafonova, N Yu; Aglietta, M; Antonioli, P; Ashikhmin, V V; Bari, G; Bertoni, R; Bressan, E; Bruno, G; Dadykin, V L; Fulgione, W; Galeotti, P; Garbini, M; Ghia, P L; Giusti, P; Kemp, E; Mal'gin, A S; Miguez, B; Molinario, A; Persiani, R; Pless, I A; Ryasny, V G; Ryazhskaya, O G; Saavedra, O; Sartorelli, G; Shakyrianova, I R; Selvi, M; Trinchero, G C; Vigorito, C; Yakushev, V F; Zichichi, A; Razeto, A

    2012-08-17

    We report the measurement of the time of flight of ∼17 GeV ν(μ) on the CNGS baseline (732 km) with the Large Volume Detector (LVD) at the Gran Sasso Laboratory. The CERN-SPS accelerator has been operated from May 10th to May 24th 2012, with a tightly bunched-beam structure to allow the velocity of neutrinos to be accurately measured on an event-by-event basis. LVD has detected 48 neutrino events, associated with the beam, with a high absolute time accuracy. These events allow us to establish the following limit on the difference between the neutrino speed and the light velocity: -3.8 × 10(-6) < (v(ν)-c)/c < 3.1 × 10(-6) (at 99% C.L.). This value is an order of magnitude lower than previous direct measurements.

  13. Floating substructure flexibility of large-volume 10MW offshore wind turbine platforms in dynamic calculations

    International Nuclear Information System (INIS)

    Borg, Michael; Hansen, Anders Melchior; Bredmose, Henrik

    2016-01-01

    Designing floating substructures for the next generation of 10MW and larger wind turbines has introduced new challenges in capturing relevant physical effects in dynamic simulation tools. In achieving technically and economically optimal floating substructures, structural flexibility may increase to the extent that it becomes relevant to include in addition to the standard rigid body substructure modes which are typically described through linear radiation-diffraction theory. This paper describes a method for the inclusion of substructural flexibility in aero-hydro-servo-elastic dynamic simulations for large-volume substructures, including wave-structure interactions, to form the basis of deriving sectional loads and stresses within the substructure. The method is applied to a case study to illustrate the implementation and relevance. It is found that the flexible mode is significantly excited in an extreme event, indicating an increase in predicted substructure internal loads. (paper)

  14. Large volume ablation of Sapphire with ultra-short laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Shamir, A., E-mail: shamirav@post.bgu.ac.il [Department of Electrical and Computer Engineering, Ben-Gurion University of the Negev, P.O.B. 653, Beer-Sheva 84105 (Israel); Electro-optics Unit, Ben-Gurion University of the Negev, P.O.B. 653, Beer-Sheva 84105 (Israel); Ishaaya, A.A. [Department of Electrical and Computer Engineering, Ben-Gurion University of the Negev, P.O.B. 653, Beer-Sheva 84105 (Israel)

    2013-04-01

    The superior optical and mechanical properties of Sapphire (Al{sub 2}O{sub 3}) are highly desirable in various opto-electronics and micro-mechanical applications. However, Sapphire's intrinsic hardness and resistance to most chemicals result in significant processing difficulties. Laser micro-machining is emerging as a promising technology, in particular, the use of ultra-short pulses for material ablation. In this work we investigate and characterize experimentally large volume ablation of Sapphire with femtosecond pulses, and compare the results to previously reported drilling and cutting experiments. We manage to identify optimized parameters for overcoming deleterious thermal effects and debris scattering, and demonstrate high quality 180 μm-deep ablation of 1 mm × 15 mm area in Sapphire.

  15. Dynamic resource management for adaptive distributed information fusion in large volume surveillance

    Science.gov (United States)

    Farahbod, Roozbeh; Glässer, Uwe; Wehn, Hans

    2008-03-01

    We propose a highly adaptive and auto-configurable, multi-layer network architecture for distributed information fusion to address large volume surveillance challenges, assuming a multitude of different sensor types on multiple mobile platforms for intelligence, surveillance and reconnaissance. Our focus is on network enabled operations to efficiently manage and improve employment of a set of mobile resources, their information fusion engines and networking capabilities under dynamically changing and essentially unpredictable conditions. A high-level model of the proposed architecture is formally described in abstract functional and operational terms based on the Abstract State Machine formalism. This description of the underlying design concepts provides a concise and precise blueprint for reasoning about key system attributes at an intuitive level of understanding.

  16. Aerodynamics of the Large-Volume, Flow-Through Detector System. Final report

    International Nuclear Information System (INIS)

    Reed, H.; Saric, W.; Laananen, D.; Martinez, C.; Carrillo, R.; Myers, J.; Clevenger, D.

    1996-03-01

    The Large-Volume Flow-Through Detector System (LVFTDS) was designed to monitor alpha radiation from Pu, U, and Am in mixed-waste incinerator offgases; however, it can be adapted to other important monitoring uses that span a number of potential markets, including site remediation, indoor air quality, radon testing, and mine shaft monitoring. Goal of this effort was to provide mechanical design information for installation of LVFTDS in an incinerator, with emphasis on ability to withstand the high temperatures and high flow rates expected. The work was successfully carried out in three stages: calculation of pressure drop through the system, materials testing to determine surrogate materials for wind-tunnel testing, and wind-tunnel testing of an actual configuration

  17. [/sup 99m/Tc] pertechnetate radionuclide venography: large-volume injection without tourniquet

    International Nuclear Information System (INIS)

    Sy, W.M.; Lao, R.S.; Bay, R.; Nash, M.

    1978-01-01

    Radionuclide venography was performed in patients who were suspected clinically to have thromboembolic disease of the lower extremities and/or pelvis. A moderately large volume of pertechnetate was administered in the dorsal vein of each foot without the benefit of applied tourniquets at the time of injection. Sixty-five (27.2%) of 242 studies were abnormal; the majority revealed defect(s) and collaterals, some collaterals only, and a few defects only. In 140 normal patients only the deep venous system was outlined in 74.5%, while the remainder defined one or both sides of the superficial venous system (great saphenous vein). The merits and apparent advantages derived from radionuclide venographic procedure are discussed. The method is simple, reproducible, and useful in assessing thromboembolic disease, particularly in the deep venous system of the lower extremities and pelvis

  18. Radio-chemical dosage of 90Sr in large volumes of drinking water

    International Nuclear Information System (INIS)

    Jeanmaire, L.; Patti, F.; Bullier, D.

    1965-01-01

    I. Principle of the method: 1. Fixing on a resin of all the cations present in the water. 2. Elution using 5 N nitric acid and precipitation of strontium as the carbonate. 3. Concentration of the strontium using the fuming nitric acid method. 4. Purification of the strontium on a resin by selective elution with ammonium citrate. 5. The strontium-90 is measured by separation at the 90 Y equilibrium in the form of the oxalate which is then counted. II. Advantages of the method The concentration of the radio-activity starting from large volumes (100 l) is generally tedious but this method which makes use of a fixation on a cationic resin makes it very simple. The rest of the method consists of a series of simple chemical operations using ion-exchange on resins and coprecipitation. Finally, it is possible to dose stable strontium. (authors) [fr

  19. Physiological and Psychological Changes Following Liposuction of Large Volumes of Fat in Overweight and Obese Women.

    Science.gov (United States)

    Geliebter, Allan; Krawitz, Emily; Ungredda, Tatiana; Peresechenski, Ella; Giese, Sharon Y

    2015-01-01

    Liposuction can remove a substantial amount of body fat. We investigated the effects of liposuction of large volumes of fat on anthropometrics, body composition (BIA), metabolic hormones, and psychological measures in overweight/obese women. To our knowledge, this is the first study to examine both physiological and psychological changes following liposuction of large volumes of fat in humans. Nine premenopausal healthy overweight/obese women (age = 35.9 ± 7.1 SD, weight = 84.4 kg ± 13.6, BMI = 29.9 kg/m 2 ± 2.9) underwent liposuction, removing 3.92 kg ± 1.04 SD of fat. Following an overnight fast, height, weight, waist, and hip circumferences were measured at baseline (one week pre-surgery) and post-surgery (wk 1,4,12). Blood samples were drawn for fasting concentrations of glucose, insulin, leptin, and ghrelin. The Body Shape Questionnaire (BSQ), Body Dysmorphic Disorder (BDD) Examination Self-Report (BDDE-SR), and Zung Self-Rating Depression Scale (ZDS) were administered. Body weight, BMI, waist circumference, and body fat consistently decreased over time ( p change significantly, but insulin decreased from wk 1 to wk 12 ( p Changes in body fat and waist circumference (baseline to wk 1) correlated positively with changes in insulin during that period, and correlated inversely with changes in ghrelin ( p change significantly. Liposuction led to significant decreases in body weight and fat, waist circumference, and leptin levels. Changes in body fat and waist circumference correlated with concurrent changes in the adipose-related hormones, insulin and ghrelin (baseline to wk 1), and body shape perception improved. Thus, besides the obvious cosmetic effects, liposuction led to several positive body composition, hormonal, and psychological changes.

  20. Volume Visualization and Compositing on Large-Scale Displays Using Handheld Touchscreen Interaction

    KAUST Repository

    Gastelum, Cristhopper Jacobo Armenta

    2011-07-27

    Advances in the physical sciences have progressively delivered ever increasing, already extremely large data sets to be analyzed. High performance volume rendering has become critical to the scientists for a better understanding of the massive amounts of data to be visualized. Cluster based rendering systems have become the base line to achieve the power and flexibility required to perform such task. Furthermore, display arrays have become the most suitable solution to display these data sets at their natural size and resolution which can be critical for human perception and evaluation. The work in this thesis aims at improving the scalability and usability of volume rendering systems that target visualization on display arrays. The first part deals with improving the performance by introducing the implementations of two parallel compositing algorithms for volume rendering: direct send and binary swap. The High quality Volume Rendering (HVR) framework has been extended to accommodate parallel compositing where previously only serial compositing was possible. The preliminary results show improvements in the compositing times for direct send even for a small number of processors. Unfortunately, the results of binary swap exhibit a negative behavior. This is due to the naive use of the graphics hardware blending mechanism. The expensive transfers account for the lengthy compositing times. The second part targets the development of scalable and intuitive interaction mechanisms. It introduces the development of a new client application for multitouch tablet devices, like the Apple iPad. The main goal is to provide the HVR framework, that has been extended to use tiled displays, a more intuitive and portable interaction mechanism that can get advantage of the new environment. The previous client is a PC application for the typical desktop settings that use a mouse and keyboard as sources of interaction. The current implementation of the client lets the user steer and

  1. Large volume serial section tomography by Xe Plasma FIB dual beam microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Burnett, T.L. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); FEI Company, Achtseweg Noord 5, Bldg, 5651 GG, Eindhoven (Netherlands); Kelley, R. [FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124 (United States); Winiarski, B. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); FEI Company, Achtseweg Noord 5, Bldg, 5651 GG, Eindhoven (Netherlands); Contreras, L. [FEI Company, 5350 NE Dawson Creek Drive, Hillsboro, OR 97124 (United States); Daly, M.; Gholinia, A.; Burke, M.G. [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); Withers, P.J., E-mail: P.J.Withers@manchester.ac.uk [School of Materials, University of Manchester, Manchester M13 9PL (United Kingdom); BP International Centre for Advanced Materials, University of Manchester, Manchester M13 9PL (United Kingdom)

    2016-02-15

    Ga{sup +} Focused Ion Beam-Scanning Electron Microscopes (FIB-SEM) have revolutionised the level of microstructural information that can be recovered in 3D by block face serial section tomography (SST), as well as enabling the site-specific removal of smaller regions for subsequent transmission electron microscope (TEM) examination. However, Ga{sup +} FIB material removal rates limit the volumes and depths that can be probed to dimensions in the tens of microns range. Emerging Xe{sup +} Plasma Focused Ion Beam-Scanning Electron Microscope (PFIB-SEM) systems promise faster removal rates. Here we examine the potential of the method for large volume serial section tomography as applied to bainitic steel and WC–Co hard metals. Our studies demonstrate that with careful control of milling parameters precise automated serial sectioning can be achieved with low levels of milling artefacts at removal rates some 60× faster. Volumes that are hundreds of microns in dimension have been collected using fully automated SST routines in feasible timescales (<24 h) showing good grain orientation contrast and capturing microstructural features at the tens of nanometres to the tens of microns scale. Accompanying electron back scattered diffraction (EBSD) maps show high indexing rates suggesting low levels of surface damage. Further, under high current Ga{sup +} FIB milling WC–Co is prone to amorphisation of WC surface layers and phase transformation of the Co phase, neither of which have been observed at PFIB currents as high as 60 nA at 30 kV. Xe{sup +} PFIB dual beam microscopes promise to radically extend our capability for 3D tomography, 3D EDX, 3D EBSD as well as correlative tomography. - Highlights: • The uptake of dual beam FIBs has been rapid but long milling times have limited imaged volumes to tens of micron dimensions. • Emerging plasma Xe{sup +} PFIB-SEM technology offers materials removal rates at least 60× greater than conventional Ga{sup +} FIB systems with

  2. Process automation system for integration and operation of Large Volume Plasma Device

    Energy Technology Data Exchange (ETDEWEB)

    Sugandhi, R., E-mail: ritesh@ipr.res.in; Srivastava, P.K.; Sanyasi, A.K.; Srivastav, Prabhakar; Awasthi, L.M.; Mattoo, S.K.

    2016-11-15

    Highlights: • Analysis and design of process automation system for Large Volume Plasma Device (LVPD). • Data flow modeling for process model development. • Modbus based data communication and interfacing. • Interface software development for subsystem control in LabVIEW. - Abstract: Large Volume Plasma Device (LVPD) has been successfully contributing towards understanding of the plasma turbulence driven by Electron Temperature Gradient (ETG), considered as a major contributor for the plasma loss in the fusion devices. Large size of the device imposes certain difficulties in the operation, such as access of the diagnostics, manual control of subsystems and large number of signals monitoring etc. To achieve integrated operation of the machine, automation is essential for the enhanced performance and operational efficiency. Recently, the machine is undergoing major upgradation for the new physics experiments. The new operation and control system consists of following: (1) PXIe based fast data acquisition system for the equipped diagnostics; (2) Modbus based Process Automation System (PAS) for the subsystem controls and (3) Data Utilization System (DUS) for efficient storage, processing and retrieval of the acquired data. In the ongoing development, data flow model of the machine’s operation has been developed. As a proof of concept, following two subsystems have been successfully integrated: (1) Filament Power Supply (FPS) for the heating of W- filaments based plasma source and (2) Probe Positioning System (PPS) for control of 12 number of linear probe drives for a travel length of 100 cm. The process model of the vacuum production system has been prepared and validated against acquired pressure data. In the next upgrade, all the subsystems of the machine will be integrated in a systematic manner. The automation backbone is based on 4-wire multi-drop serial interface (RS485) using Modbus communication protocol. Software is developed on LabVIEW platform using

  3. Process automation system for integration and operation of Large Volume Plasma Device

    International Nuclear Information System (INIS)

    Sugandhi, R.; Srivastava, P.K.; Sanyasi, A.K.; Srivastav, Prabhakar; Awasthi, L.M.; Mattoo, S.K.

    2016-01-01

    Highlights: • Analysis and design of process automation system for Large Volume Plasma Device (LVPD). • Data flow modeling for process model development. • Modbus based data communication and interfacing. • Interface software development for subsystem control in LabVIEW. - Abstract: Large Volume Plasma Device (LVPD) has been successfully contributing towards understanding of the plasma turbulence driven by Electron Temperature Gradient (ETG), considered as a major contributor for the plasma loss in the fusion devices. Large size of the device imposes certain difficulties in the operation, such as access of the diagnostics, manual control of subsystems and large number of signals monitoring etc. To achieve integrated operation of the machine, automation is essential for the enhanced performance and operational efficiency. Recently, the machine is undergoing major upgradation for the new physics experiments. The new operation and control system consists of following: (1) PXIe based fast data acquisition system for the equipped diagnostics; (2) Modbus based Process Automation System (PAS) for the subsystem controls and (3) Data Utilization System (DUS) for efficient storage, processing and retrieval of the acquired data. In the ongoing development, data flow model of the machine’s operation has been developed. As a proof of concept, following two subsystems have been successfully integrated: (1) Filament Power Supply (FPS) for the heating of W- filaments based plasma source and (2) Probe Positioning System (PPS) for control of 12 number of linear probe drives for a travel length of 100 cm. The process model of the vacuum production system has been prepared and validated against acquired pressure data. In the next upgrade, all the subsystems of the machine will be integrated in a systematic manner. The automation backbone is based on 4-wire multi-drop serial interface (RS485) using Modbus communication protocol. Software is developed on LabVIEW platform using

  4. Assessing the Validity of Single-item Life Satisfaction Measures: Results from Three Large Samples

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E.

    2014-01-01

    Purpose The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS) - a more psychometrically established measure. Methods Two large samples from Washington (N=13,064) and Oregon (N=2,277) recruited by the Behavioral Risk Factor Surveillance System (BRFSS) and a representative German sample (N=1,312) recruited by the Germany Socio-Economic Panel (GSOEP) were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Results Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62 – 0.64; disattenuated r = 0.78 – 0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001 – 0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS were very small (average absolute difference = 0.015 −0.042). Conclusions Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use. PMID:24890827

  5. Assessing the validity of single-item life satisfaction measures: results from three large samples.

    Science.gov (United States)

    Cheung, Felix; Lucas, Richard E

    2014-12-01

    The present paper assessed the validity of single-item life satisfaction measures by comparing single-item measures to the Satisfaction with Life Scale (SWLS)-a more psychometrically established measure. Two large samples from Washington (N = 13,064) and Oregon (N = 2,277) recruited by the Behavioral Risk Factor Surveillance System and a representative German sample (N = 1,312) recruited by the Germany Socio-Economic Panel were included in the present analyses. Single-item life satisfaction measures and the SWLS were correlated with theoretically relevant variables, such as demographics, subjective health, domain satisfaction, and affect. The correlations between the two life satisfaction measures and these variables were examined to assess the construct validity of single-item life satisfaction measures. Consistent across three samples, single-item life satisfaction measures demonstrated substantial degree of criterion validity with the SWLS (zero-order r = 0.62-0.64; disattenuated r = 0.78-0.80). Patterns of statistical significance for correlations with theoretically relevant variables were the same across single-item measures and the SWLS. Single-item measures did not produce systematically different correlations compared to the SWLS (average difference = 0.001-0.005). The average absolute difference in the magnitudes of the correlations produced by single-item measures and the SWLS was very small (average absolute difference = 0.015-0.042). Single-item life satisfaction measures performed very similarly compared to the multiple-item SWLS. Social scientists would get virtually identical answer to substantive questions regardless of which measure they use.

  6. Active species in a large volume N2-O2 post-discharge reactor

    International Nuclear Information System (INIS)

    Kutasi, K; Pintassilgo, C D; Loureiro, J; Coelho, P J

    2007-01-01

    A large volume post-discharge reactor placed downstream from a flowing N 2 -O 2 microwave discharge is modelled using a three-dimensional hydrodynamic model. The density distributions of the most populated active species present in the reactor-O( 3 P), O 2 (a 1 Δ g ), O 2 (b 1 Σ g + ), NO(X 2 Π), NO(A 2 Σ + ), NO(B 2 Π), NO 2 (X), O 3 , O 2 (X 3 Σ g - ) and N( 4 S)-are calculated and the main source and loss processes for each species are identified for two discharge conditions: (i) p = 2 Torr, f = 2450 MHz, and (ii) p = 8 Torr, f = 915 MHz; in the case of a N 2 -2%O 2 mixture composition and gas flow rate of 2 x 10 3 sccm. The modification of the species relative densities by changing the oxygen percentage in the initial gas mixture composition, in the 0.2%-5% range, are presented. The possible tuning of the species concentrations in the reactor by changing the size of the connecting afterglow tube between the active discharge and the large post-discharge reactor is investigated as well

  7. Analytical and Experimental Investigation of Mixing in Large Passive Containment Volumes

    International Nuclear Information System (INIS)

    Peterson, Per F.

    2002-01-01

    This final report details results from the past three years of the three-year UC Berkeley NEER investigation of mixing phenomena in large-scale passive reactor containments. We have completed all of our three-year deliverables specified in our proposal, as summarized for each deliverable in the body of this report, except for the experiments of steam condensation in the presence of noncondensable gas. We have particularly exiting results from the experiments studying the mixing in large insulated containment with a vertical cooling plate. These experiments now have shown why augmentation has been observed in wall-condensation experiments due to the momentum of the steam break-flow entering large volumes. More importantly, we also have shown that the forced-jet augmentation can be predicted using relatively simple correlations, and that it is independent of the break diameter and depends only on the break flow orientation, location, and momentum. This suggests that we will now be able to take credit for this augmentation in reactor safety analysis, improving safety margins for containment structures. We have finished the version 1 of 1-D Lagrangian flow and heat transfer code BMIX++. This version has ability to solve many complex stratified problems, such as multi-components problems, multi-enclosures problems (two enclosures connected by one connection for the current version), incompressible and compressible problems, multi jets, plumes, sinks in one enclosure problems, problems with wall conduction, and the combinations of the above problems. We believe the BMIX++ code is a very powerful computation tool to study stratified enclosures mixing problems

  8. The method of arbitrarily large moments to calculate single scale processes in quantum field theory

    Directory of Open Access Journals (Sweden)

    Johannes Blümlein

    2017-08-01

    Full Text Available We devise a new method to calculate a large number of Mellin moments of single scale quantities using the systems of differential and/or difference equations obtained by integration-by-parts identities between the corresponding Feynman integrals of loop corrections to physical quantities. These scalar quantities have a much simpler mathematical structure than the complete quantity. A sufficiently large set of moments may even allow the analytic reconstruction of the whole quantity considered, holding in case of first order factorizing systems. In any case, one may derive highly precise numerical representations in general using this method, which is otherwise completely analytic.

  9. The method of arbitrarily large moments to calculate single scale processes in quantum field theory

    Energy Technology Data Exchange (ETDEWEB)

    Bluemlein, Johannes [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany); Schneider, Carsten [Johannes Kepler Univ., Linz (Austria). Research Inst. for Symbolic Computation (RISC)

    2017-01-15

    We device a new method to calculate a large number of Mellin moments of single scale quantities using the systems of differential and/or difference equations obtained by integration-by-parts identities between the corresponding Feynman integrals of loop corrections to physical quantities. These scalar quantities have a much simpler mathematical structure than the complete quantity. A sufficiently large set of moments may even allow the analytic reconstruction of the whole quantity considered, holding in case of first order factorizing systems. In any case, one may derive highly precise numerical representations in general using this method, which is otherwise completely analytic.

  10. Large rotating magnetocaloric effect in ErAlO3 single crystal

    Directory of Open Access Journals (Sweden)

    X. Q. Zhang

    2017-05-01

    Full Text Available Magnetic and magnetocaloric properties of ErAlO3 single crystal were investigated. Magnetization of ErAlO3 shows obvious anisotropy when magnetic field is applied along the a, b and c axes, which leads to large anisotropic magnetic entropy change. In particular, large rotating field entropy change from the b to c axis within the bc plane is obtained and reaches 9.7 J/kg K at 14 K in a field of 5 T. This suggests the possibility of using ErAlO3 single crystal for magnetic refrigerators by rotating its magnetization vector rather than moving it in and out of the magnet.

  11. The influence of single low dose of recombinant human thyrotropin on I-131 treatment of large multi-nodular goitre

    International Nuclear Information System (INIS)

    Mojsak, M.N.; Abdelrazek, S.; Rogowski, F.; Szunowski, P.; Mysliwiec, J.; Kociura-Sawicka, A.

    2015-01-01

    Full text of publication follows. Recombinant human thyrotropin (rhTSH) is a substance that after single intramuscular injection can increase thyroid radioiodine uptake (RAIU) and improve the results of radioiodine therapy (RIT) in patients with nontoxic multi-nodular goitre (MNG). These effects are very important especially in cases of large MNG with relatively low RAIU or contraindications to surgery. The aim of the study: the evaluation of the influence of the single low dose of rhTSH to RAIU and the effects of RIT in patients with benign large nontoxic MNG. Material and methods: 40 patients (14 male, 26 female, age 41-80 yr) with large MNG > 100 grams and with baseline RAIU < 40% (33,37±7,96%) were included to the study and divided into two groups. First group received the single intramuscular injection of 0,03 mg rhTSH and the second received placebo. The RAIU were measured again 48 hours after the rhTSH (24 hours after diagnostic dose of I-131). After this, all the patients were administered the therapeutic doses of I-131 recalculated according to new RAIU. The patients follow up was continued for minimum 12 months. Results: the mean RAIU after rhTSH increased more than twice, to 75% from 33%. One year after RIT the mean volume goitre reduction were significantly greater in group with rhTSH than in patients with placebo (48±16% vs. 37±18%). Decrease of compression symptoms has taken place earlier and was more important in patients after rhTSH. 12 months after RIT two patients stay in hypothyroid state (from the group with rhTSH), other patients are euthyroid. Conclusions: even the single very low dose of rhTSH increases the values of RAIU in significant way. Efficacy of rhTSH-augmented RIT in patients with large nontoxic MNG is greater than standard RIT. It allows to reduce administered doses of I-131, decreases the need of repeating RIT, makes the radiation adsorbed doses for whole body lower and the RIT shorter. (authors)

  12. Development of large Grain/Single Crystal Niobium Cavity Technology at Jefferson Lab

    Energy Technology Data Exchange (ETDEWEB)

    Peter Kneisel; J. Sekutowicz; T. Carneiro; G. Ciovati

    2006-10-31

    Approximately two years ago we started to develop high performance niobium accelerating cavities based on large grain or single crystal high purity niobium. We have fabricated and tested 15 single cell cavities of various shapes and frequencies between 1300 MHz and 2300 MHz using material from a total of 9 different very large grain niobium ingots from four niobium suppliers. The materials differed not only in grain sizes, but also in RRR ? value and in the amount of Ta contained in the material. In one ingot supplied by CBMM the central grain exceeded 7 inches in diameter and this was used to fabricate two 2.2 GHz cavities. A single crystal 1300 MHz mono-cell cavity was also produced at DESY by rolling out a single crystal to the size required for this cavity. It was sent to Jlab for surface treatment and testing. In addition, we have fabricated three 7-cell cavities: two of the Jlab high gradient (HG) shape and one of the ILC Low Loss shape. Two 9-cell TESLA shape cavities are presently in fabrication at Jlab and are close to completion.

  13. Development of large-volume, high-resolution tracking detectors based on capillaries filled with liquid scintillator

    International Nuclear Information System (INIS)

    Buontempo, S.; Fabre, J.P.; Frenkel, A.; Gregoire, G.; Hoepfner, K.; Konijn, J.; Kozarenko, E.; Kreslo, I.; Kushnirenko, A.; Martellotti, G.; Michel, L.; Mondardini, M.R.; Penso, G.; Siegmund, W.P.; Strack, R.; Tyukov, V.; Vasilchenko, V.; Vilain, P.; Wilquet, G.; Winter, K.; Wong, H.; Zymin, K.

    1995-01-01

    Searches for the decay of short-lived particles require real time, high-resolution tracking in active targets, which in the case of neutrino physics should be of large volume. The possibility of achieving this by using glass capillaries filled with organic liquid scintillator is being investigated in the framework of the CHORUS experiment at CERN. In this paper, after outlining the application foreseen, advances in the tracking technique are discussed and results from tests are reported. An active target of dimensions 180x2x2 cm 3 has been assembled from capillaries with 20 μm diameter pores. The readout scheme currently in operation allows the reading of similar 5x10 5 channels using a single chain of image intensifiers having a resolution of σ similar 20 μm. Following the development of new liquid scintillators and purification methods an attenuation length of similar 3 m has been obtained. This translates into a hit density of 3.5 per mm for a minimum-ionizing particle that crosses the active target at a distance of 1 m from the readout end. (orig.)

  14. Large-Scale Mixed Temperate Forest Mapping at the Single Tree Level using Airborne Laser Scanning

    Science.gov (United States)

    Scholl, V.; Morsdorf, F.; Ginzler, C.; Schaepman, M. E.

    2017-12-01

    Monitoring vegetation on a single tree level is critical to understand and model a variety of processes, functions, and changes in forest systems. Remote sensing technologies are increasingly utilized to complement and upscale the field-based measurements of forest inventories. Airborne laser scanning (ALS) systems provide valuable information in the vertical dimension for effective vegetation structure mapping. Although many algorithms exist to extract single tree segments from forest scans, they are often tuned to perform well in homogeneous coniferous or deciduous areas and are not successful in mixed forests. Other methods are too computationally expensive to apply operationally. The aim of this study was to develop a single tree detection workflow using leaf-off ALS data for the canton of Aargau in Switzerland. Aargau covers an area of over 1,400km2 and features mixed forests with various development stages and topography. Forest type was classified using random forests to guide local parameter selection. Canopy height model-based treetop maxima were detected and maintained based on the relationship between tree height and window size, used as a proxy to crown diameter. Watershed segmentation was used to generate crown polygons surrounding each maximum. The location, height, and crown dimensions of single trees were derived from the ALS returns within each polygon. Validation was performed through comparison with field measurements and extrapolated estimates from long-term monitoring plots of the Swiss National Forest Inventory within the framework of the Swiss Federal Institute for Forest, Snow, and Landscape Research. This method shows promise for robust, large-scale single tree detection in mixed forests. The single tree data will aid ecological studies as well as forest management practices. Figure description: Height-normalized ALS point cloud data (top) and resulting single tree segments (bottom) on the Laegeren mountain in Switzerland.

  15. Properties of 8-inch photomultiplier tubes for a large volume imaging water Cerenkov detector

    International Nuclear Information System (INIS)

    Oehler, Ch.

    1996-01-01

    In the Institut fuer Kernphysik I conceptional studies for a possible succession project for the KARMEN-ν-detector are performed. This design studies propose to build a large volume 1300 t imaging water Cerenkov detector. The main goal of this experiment will be the investigation of ν-e - -scattering in the medium energy range up to 50 MeV. The sensitive surface of this detector will be instrumented with about 3000 8-inch photomultiplier tubes (PMT) providing a coverage of 20%. In the framework of this detector design, studies of the properties of hemispherical 8-inch phototubes have been investigated in this work. The topic was to optimise the quality of the important PMT properties like time- and energy-resolution which are crucial to achieve the required spatial and angular resolutions. A second task of this work was to construct a test facility for the PMT, with the possibility to test large quantities. Monte Carlo calculations show that the required detector resolutions of σ E /E(E e ≤50 MeV)=5.2%+47%/√E, σ t (E e ∼30 MeV)=0.6 ns, σ x (E e ∼30 MeV)=13 cm, σ Θ (E e ∼30 MeV)=20 , can be achieved if the phototubes have a transit-time spread less than 1 ns. Up to now, two different 8-inch tubes are available and have been tested, the HAMAMATSU R5912 and the EMI 9353. (orig.)

  16. On 'light' fermions and proton stability in 'big divisor' D3/D7 large volume compactifications

    International Nuclear Information System (INIS)

    Misra, Aalok; Shukla, Pramod

    2011-01-01

    Building on our earlier work (Misra and Shukla, Nucl. Phys. B 827:112, 2010; Phys. Lett. B 685:347-352, 2010), we show the possibility of generating ''light'' fermion mass scales of MeV-GeV range (possibly related to the first two generations of quarks/leptons) as well as eV (possibly related to first two generations of neutrinos) in type IIB string theory compactified on Swiss-Cheese orientifolds in the presence of a mobile space-time filling D3-brane restricted to (in principle) stacks of fluxed D7-branes wrapping the ''big'' divisor Σ B . This part of the paper is an expanded version of the latter half of Sect. 3 of a published short invited review (Misra, Mod. Phys. Lett. A 26:1, 2011) written by one of the authors [AM ]. Further, we also show that there are no SUSY GUT-type dimension-five operators corresponding to proton decay, and we estimate the proton lifetime from a SUSY GUT-type four-fermion dimension-six operator to be 10 61 years. Based on GLSM calculations in (Misra and Shukla, Nucl. Phys. B 827:112, 2010) for obtaining the geometric Kaehler potential for the ''big divisor,'' using further the Donaldson's algorithm, we also briefly discuss in the first of the two appendices the metric for the Swiss-Cheese Calabi-Yau used, which we obtain and which becomes Ricci flat in the large-volume limit. (orig.)

  17. Development testing of large volume water sprays for warm fog dispersal

    Science.gov (United States)

    Keller, V. W.; Anderson, B. J.; Burns, R. A.; Lala, G. G.; Meyer, M. B.; Beard, K. V.

    1986-01-01

    A new brute-force method of warm fog dispersal is described. The method uses large volume recycled water sprays to create curtains of falling drops through which the fog is processed by the ambient wind and spray induced air flow. Fog droplets are removed by coalescence/rainout. The efficiency of the technique depends upon the drop size spectra in the spray, the height to which the spray can be projected, the efficiency with which fog laden air is processed through the curtain of spray, and the rate at which new fog may be formed due to temperature differences between the air and spray water. Results of a field test program, implemented to develop the data base necessary to assess the proposed method, are presented. Analytical calculations based upon the field test results indicate that this proposed method of warm fog dispersal is feasible. Even more convincingly, the technique was successfully demonstrated in the one natural fog event which occurred during the test program. Energy requirements for this technique are an order of magnitude less than those to operate a thermokinetic system. An important side benefit is the considerable emergency fire extinguishing capability it provides along the runway.

  18. High-Dimensional Function Approximation With Neural Networks for Large Volumes of Data.

    Science.gov (United States)

    Andras, Peter

    2018-02-01

    Approximation of high-dimensional functions is a challenge for neural networks due to the curse of dimensionality. Often the data for which the approximated function is defined resides on a low-dimensional manifold and in principle the approximation of the function over this manifold should improve the approximation performance. It has been show that projecting the data manifold into a lower dimensional space, followed by the neural network approximation of the function over this space, provides a more precise approximation of the function than the approximation of the function with neural networks in the original data space. However, if the data volume is very large, the projection into the low-dimensional space has to be based on a limited sample of the data. Here, we investigate the nature of the approximation error of neural networks trained over the projection space. We show that such neural networks should have better approximation performance than neural networks trained on high-dimensional data even if the projection is based on a relatively sparse sample of the data manifold. We also find that it is preferable to use a uniformly distributed sparse sample of the data for the purpose of the generation of the low-dimensional projection. We illustrate these results considering the practical neural network approximation of a set of functions defined on high-dimensional data including real world data as well.

  19. Development of a large mosaic volume phase holographic (VPH) grating for APOGEE

    Science.gov (United States)

    Arns, James; Wilson, John C.; Skrutskie, Mike; Smee, Steve; Barkhouser, Robert; Eisenstein, Daniel; Gunn, Jim; Hearty, Fred; Harding, Al; Maseman, Paul; Holtzman, Jon; Schiavon, Ricardo; Gillespie, Bruce; Majewski, Steven

    2010-07-01

    Volume phase holographic (VPH) gratings are increasingly being used as diffractive elements in astronomical instruments due to their potential for very high peak diffraction efficiencies and the possibility of a compact instrument design when the gratings are used in transmission. Historically, VPH grating (VPHG) sizes have been limited by the size of manufacturer's holographic recording optics. We report on the design, specification and fabrication of a large, 290 mm × 475 mm elliptically-shaped, mosaic VPHG for the Apache Point Observatory Galactic Evolution Experiment (APOGEE) spectrograph. This high-resolution near-infrared multi-object spectrograph is in construction for the Sloan Digital Sky Survey III (SDSS III). The 1008.6 lines/mm VPHG was designed for optimized performance over a wavelength range from 1.5 to 1.7 μm. A step-and-repeat exposure method was chosen to fabricate a three-segment mosaic on a 305 mm × 508 mm monolithic fused-silica substrate. Specification considerations imposed on the VPHG to assure the mosaic construction will satisfy the end use requirements are discussed. Production issues and test results of the mosaic VPHG are discussed.

  20. Low Energy Neutrino Astronomy in the future large-volume liquid-scintillator detector LENA

    International Nuclear Information System (INIS)

    Wurm, Michael; Feilitzsch, F V; Goeger-Neff, M; Lewke, T; Undagoitia, T Marrodan; Oberauer, L; Potzel, W; Todor, S; Winter, J

    2008-01-01

    The recent successes in neutrino physics prove that liquid-scintillator detectors allow to combine high energy resolution, efficient means of background reduction, and a large detection volume. In the planned LENA (Low Energy Neutrino Astronomy) experiment, a target mass of 50 kt will enable the investigation of a variety of terrestrial and astrophysical neutrino sources. The high-statistics spectroscopy of geoneutrinos, solar neutrinos and supernova neutrinos will provide new insights in the heat production processes of Earth and Sun, and the workings of a gravitational collapse. The same measurements will as well investigate neutrino properties as oscillation parameters and mass hierarchy. A first spectroscopic measurement of the low flux of diffuse supernova neutrino background is within the sensitivity of the LENA detector. Finally, a life-time limit of several 1034 years can be set to the proton decay into proton and anti-neutrino, testing the predictions of SUSY theory. The present contribution includes a review of the scientific studies that were performed in the last years as well as a report on currently on-going R and D activities.

  1. Curling probe measurement of a large-volume pulsed plasma with surface magnetic confinement

    Science.gov (United States)

    Pandey, A.; Tashiro, H.; Sakakibara, W.; Nakamura, K.; Sugai, H.

    2016-12-01

    A curling probe (CP) based on microwave resonance is applied to the measurement of electron density in a pulsed DC glow discharge under surface magnetic confinement (SMC) provided by a number of permanent magnets on a chamber wall. Owing to the SMC effects, a 1 m scale large-volume plasma is generated by a relatively low voltage (~1 kV) at low pressure (~1 Pa) in various gases (Ar, CH4, and C2H2). Temporal variation of the electron density is measured for pulse frequency f  =  0.5-25 kHz for various discharge-on times (T ON) with a high resolution time (~0.2 µs), using the on-point mode. In general, the electron density starts to increase at time t  =  0 after turn-on of the discharge voltage, reaches peak density at t  =  T ON, and then decreases after turn-off. The peak electron density is observed to increase with the pulse frequency f for constant T ON owing to the residual plasma. This dependence is successfully formulated using a semi-empirical model. The spatio-temporal evolution of the cathode sheath in the pulsed discharge is revealed by a 1 m long movable CP. The measured thickness of the high-voltage cathode fall in a steady state coincides with the value of the so-called Child-Langmuir sheath.

  2. Electrical characterization of large volume CdZnTe coplanar detectors

    International Nuclear Information System (INIS)

    Gonzalez, R.; Perez, J.M.; Vela, O.; Burgos, E. de; Oller, J.C.; Gostilo, V.

    2005-01-01

    The electrical behaviors of two large volume CZT coplanar detectors in the voltage and temperature application range are presented in this work. Two different regions are treated: bulk and anode surface. I-V curves were acquired at different temperatures in these two regions. Experimental results were analyzed by treating the device as a metal-semiconductor Schottky barrier. Two different formulations were used for modeling this structure: the interfacial-layer thermionic-diffusion model, considered as a complete and general theory, and the diffusion model as a more specific approach. It will be shown that the diffusion model is sufficient to reproduce the results obtained for biases and temperatures normally used in operation. A detailed description of this model is provided. In the anode face, the diffusion model is compared with the space-charge-limited current theory. Differences found in the two regions studied are outlined in this paper. Finally, the influence of the electrical parameters in the design of future detectors is discussed

  3. A model for steady-state large-volume plasma generation

    International Nuclear Information System (INIS)

    Uhm, H.S.; Miller, J.D.; Schneider, R.F.

    1991-01-01

    In this paper, a simple, new scheme to generate a uniform, steady-state, large-volume plasma is presented. The weakly magnetized plasma is created by direct ionization of the background gas by low-energy electrons generated from thermionic filaments. An annular arrangement of the filaments ensures a uniform plasma density in the radial direction as predicted by theory. Experiments have been performed to characterize the plasma generated in such a configuration. In order to explain the experimental observation, we develop a bulk plasma theory based on plasma transport via cross-field diffusion. As assumed in the theoretical model, the experimental measurements indicate a uniform plasma density along the axis. Both the theory and experiment indicate that the plasma density is a function of the square of the external magnetic field. The theory also predicts the plasma density to be proportional to the neutral density to the two-thirds power in agreement with the experimental data. We also observe the experimental data to agree remarkably well with theoretical prediction for a broad range of system parameters

  4. Performance of the Goulden large volume sampler for acidic compounds in natural waters

    Energy Technology Data Exchange (ETDEWEB)

    Headley, J.; Dickson, L. [National Hydrology Research Inst., Saskatoon, Saskatchewan (Canada); Swyngedouw, C. [Chemex Labs Alberta Inc., Calgary, Alberta (Canada); Crosley, D. [Water Quality Lab., Calgary, Alberta (Canada); Whitley, G. [Department of Indian and Northern Affairs, Whitehorse, Yukon (Canada)

    1995-12-31

    The Goulden large volume sampler (LVX) has received extensive use for monitoring and surveillance surveys of natural waters impacted by pulp and paper mills, and agricultural run-off water. Despite this use, there is a lack of performance criteria for acidic contaminants, There are concerns about whether this sampler which was originally developed for extractions of OCs, PCBs and PAHs, was suitable for sampling polar acidic compounds. Performance tests conducted in this work, indicated that with the exception of 4-bromophenol and dichlorophenylacetic acid, surrogate compounds were recovered from pH 2 adjusted samples (20 1) at approximately 80 {+-} 15--35% recovery. Although these recoveries were comparable to values attainable for neutral pesticides, the standard deviations were up to four times greater than values reported for neutral compounds, for concentrations of analytes at low ppt levels. Specific performance criteria (percent recoveries where the number of determinations are given in parenthesis) observed for the proposed surrogates heptadecanoic acid, dichlorophenylacetic acid, 4-bromophenol, o-methylpodocarpic acid and 2,4,6-tribromophenol were: 86.6(19) {+-} 26.8; 46.1(18) {+-} 14.5; 31.6(19) {+-} 24.1; 78.4(18) {+-} 14.7; and95.2(18) {+-} 33.6 respectively. These values can be used to provide guidelines for acceptable surrogate recoveries, and validation of extractions of acidic polar compounds.

  5. Hepatic Arterial Embolization and Chemoembolization in the Management of Patients with Large-Volume Liver Metastases

    International Nuclear Information System (INIS)

    Kamat, Paresh P.; Gupta, Sanjay; Ensor, Joe E.; Murthy, Ravi; Ahrar, Kamran; Madoff, David C.; Wallace, Michael J.; Hicks, Marshall E.

    2008-01-01

    The purpose of this study was to assess the role of hepatic arterial embolization (HAE) and chemoembolization (HACE) in patients with large-volume liver metastases. Patients with metastatic neuroendocrine tumors, melanomas, or gastrointestinal stromal tumors (GISTs) with >75% liver involvement who underwent HAE or HACE were included in the study. Radiologic response, progression-free survival (PFS), overall survival (OS), and postprocedure complications were assessed. Sixty patients underwent 123 treatment sessions. Of the 48 patients for whom follow-up imaging was available, partial response was seen in 12 (25%) patients, minimal response in 6 (12%), stable disease in 22 (46%), and progressive disease in 8 (17%). Median OS and PFS were 9.3 and 4.9 months, respectively. Treatment resulted in radiologic response or disease stabilization in 82% and symptomatic response in 65% of patients with neuroendocrine tumors. Patients with neuroendocrine tumors had higher response rates (44% vs. 27% and 0%; p = 0.31) and longer PFS (9.2 vs. 2.0 and 2.3 months; p 75% liver involvement, HAE/HACE resulted in symptom palliation and radiologic response or disease stabilization in the majority of patients. Patients with hepatic metastases from melanomas and GISTs, however, did not show any appreciable benefit from this procedure. Patients with massive liver tumor burden, who have additional risk factors, should not be subjected to HAE/HACE because of the high risk of procedure-related mortality

  6. Fat Embolism as a Rare Complication of Large-volume Liposuction in a Plastic Patient

    Directory of Open Access Journals (Sweden)

    Xiaoliang Fu

    2015-01-01

    Full Text Available Fat embolism is a dreaded complication in of procedures of multiple disciplines including plastic surgery. As the popularity of liposuction increases, cases of pulmonary embolism after liposuction are increasingly reported. However, documents of cerebral embolism after liposuction are rarely presented. The degree of disability with respect to Fat fat Embolism embolism Symdrome syndrome (FES is a Gordian Knot in the evaluation of legal medicine. Therefore, it is of great significance for us to that we report the case of a 30-year-old woman who underwent a large-volume liposuction that resulted in serious complications, especially cerebral embolism. Untypical symptoms of fat embolism hamper the clinical diagnosis, particularly after a surgical procedure such as liposuction. Such a seldom-seen case would easily trigger medical disputes, especially in countries like China suffering increasing claims of medical malpractice and, medical negligences and lawsuits. Detailed descriptions of this case are presented below along with the discussion of the clinical symptoms and the diagnostic approaches to fat embolism.

  7. Coupled Finite Volume and Finite Element Method Analysis of a Complex Large-Span Roof Structure

    Directory of Open Access Journals (Sweden)

    Szafran J.

    2017-12-01

    Full Text Available The main goal of this paper is to present coupled Computational Fluid Dynamics and structural analysis for the precise determination of wind impact on internal forces and deformations of structural elements of a longspan roof structure. The Finite Volume Method (FVM serves for a solution of the fluid flow problem to model the air flow around the structure, whose results are applied in turn as the boundary tractions in the Finite Element Method problem structural solution for the linear elastostatics with small deformations. The first part is carried out with the use of ANSYS 15.0 computer system, whereas the FEM system Robot supports stress analysis in particular roof members. A comparison of the wind pressure distribution throughout the roof surface shows some differences with respect to that available in the engineering designing codes like Eurocode, which deserves separate further numerical studies. Coupling of these two separate numerical techniques appears to be promising in view of future computational models of stochastic nature in large scale structural systems due to the stochastic perturbation method.

  8. Coupled Finite Volume and Finite Element Method Analysis of a Complex Large-Span Roof Structure

    Science.gov (United States)

    Szafran, J.; Juszczyk, K.; Kamiński, M.

    2017-12-01

    The main goal of this paper is to present coupled Computational Fluid Dynamics and structural analysis for the precise determination of wind impact on internal forces and deformations of structural elements of a longspan roof structure. The Finite Volume Method (FVM) serves for a solution of the fluid flow problem to model the air flow around the structure, whose results are applied in turn as the boundary tractions in the Finite Element Method problem structural solution for the linear elastostatics with small deformations. The first part is carried out with the use of ANSYS 15.0 computer system, whereas the FEM system Robot supports stress analysis in particular roof members. A comparison of the wind pressure distribution throughout the roof surface shows some differences with respect to that available in the engineering designing codes like Eurocode, which deserves separate further numerical studies. Coupling of these two separate numerical techniques appears to be promising in view of future computational models of stochastic nature in large scale structural systems due to the stochastic perturbation method.

  9. A Parallel, Finite-Volume Algorithm for Large-Eddy Simulation of Turbulent Flows

    Science.gov (United States)

    Bui, Trong T.

    1999-01-01

    A parallel, finite-volume algorithm has been developed for large-eddy simulation (LES) of compressible turbulent flows. This algorithm includes piecewise linear least-square reconstruction, trilinear finite-element interpolation, Roe flux-difference splitting, and second-order MacCormack time marching. Parallel implementation is done using the message-passing programming model. In this paper, the numerical algorithm is described. To validate the numerical method for turbulence simulation, LES of fully developed turbulent flow in a square duct is performed for a Reynolds number of 320 based on the average friction velocity and the hydraulic diameter of the duct. Direct numerical simulation (DNS) results are available for this test case, and the accuracy of this algorithm for turbulence simulations can be ascertained by comparing the LES solutions with the DNS results. The effects of grid resolution, upwind numerical dissipation, and subgrid-scale dissipation on the accuracy of the LES are examined. Comparison with DNS results shows that the standard Roe flux-difference splitting dissipation adversely affects the accuracy of the turbulence simulation. For accurate turbulence simulations, only 3-5 percent of the standard Roe flux-difference splitting dissipation is needed.

  10. Stability and compatibility of lidocaine hydrochloride with selected large-volume parenterals and drug additives.

    Science.gov (United States)

    Kirschenbaum, H L; Aronoff, W; Perentesis, G P; Plitz, G W; Cutie, A J

    1982-06-01

    The stability of lidocaine hydrochloride in six commonly used large-volume parenterals when stored for 14 days and the visual compatibility of lidocaine hydrochloride in admixtures with eight frequently used drugs were studied. Lidocaine hydrochloride admixtures of 2 mg/ml were prepared in both glass and plastic containers of 5% dextrose injection, 0.9% sodium chloride injection, lactated Ringer's injection, 5% dextrose and lactated Ringer's injection, 0.45% sodium chloride injection (plastic container only), and 0.45% sodium chloride and 5% dextrose injection. The admixtures were examined visually and stored for 14 days at 25 +/- 0.5 degrees C under fluorescent light. Lidocaine hydrochloride concentrations were determined spectrophotometrically at times 0, 0.25, 1, 3, 8, and 24 hours, and at 24-hour intervals thereafter. Spectrophotometric assays were confirmed with high-pressure liquid chromatography. Admixtures of lidocaine hydrochloride were prepared with aminophylline, bretylium tosylate, calcium gluconate, digoxin, dopamine hydrochloride, regular insulin, phenytoin sodium, and procainamide hydrochloride in 5% dextrose injection, 0.9% sodium chloride injection, and lactated Ringer's injection. The admixtures were examined visually for 24 hours. Admixtures of lidocaine hydrochloride were stable for 14 days. All admixtures of lidocaine hydrochloride with other drugs were visually compatible except those containing phenytoin sodium. It is concluded that lidocaine hydrochloride is stable in the solutions studied for 14 days at 25 degrees C and visually compatible for 24 hours in admixtures containing all drugs studied except phenytoin sodium.

  11. Photoperiod is associated with hippocampal volume in a large community sample.

    Science.gov (United States)

    Miller, Megan A; Leckie, Regina L; Donofry, Shannon D; Gianaros, Peter J; Erickson, Kirk I; Manuck, Stephen B; Roecklein, Kathryn A

    2015-04-01

    Although animal research has demonstrated seasonal changes in hippocampal volume, reflecting seasonal neuroplasticity, seasonal differences in human hippocampal volume have yet to be documented. Hippocampal volume has also been linked to depressed mood, a seasonally varying phenotype. Therefore, we hypothesized that seasonal differences in day-length (i.e., photoperiod) would predict differences in hippocampal volume, and that this association would be linked to low mood. Healthy participants aged 30-54 (M=43; SD=7.32) from the University of Pittsburgh Adult Health and Behavior II project (n=404; 53% female) were scanned in a 3T MRI scanner. Hippocampal volumes were determined using an automated segmentation algorithm using FreeSurfer. A mediation model tested whether hippocampal volume mediated the relationship between photoperiod and mood. Secondary analyses included seasonally fluctuating variables (i.e., sleep and physical activity) which have been shown to influence hippocampal volume. Shorter photoperiods were significantly associated with higher BDI scores (R(2)=0.01, β=-0.12, P=0.02) and smaller hippocampal volumes (R(2)=0.40, β=0.08, P=0.04). However, due to the lack of an association between hippocampal volume and Beck Depression Inventory scores in the current sample, the mediation hypothesis was not supported. This study is the first to demonstrate an association between season and hippocampal volume. These data offer preliminary evidence that human hippocampal plasticity could be associated with photoperiod and indicates a need for longitudinal studies. © 2014 Wiley Periodicals, Inc.

  12. Solution coating of large-area organic semiconductor thin films with aligned single-crystalline domains

    KAUST Repository

    Diao, Ying

    2013-06-02

    Solution coating of organic semiconductors offers great potential for achieving low-cost manufacturing of large-area and flexible electronics. However, the rapid coating speed needed for industrial-scale production poses challenges to the control of thin-film morphology. Here, we report an approach - termed fluid-enhanced crystal engineering (FLUENCE) - that allows for a high degree of morphological control of solution-printed thin films. We designed a micropillar-patterned printing blade to induce recirculation in the ink for enhancing crystal growth, and engineered the curvature of the ink meniscus to control crystal nucleation. Using FLUENCE, we demonstrate the fast coating and patterning of millimetre-wide, centimetre-long, highly aligned single-crystalline organic semiconductor thin films. In particular, we fabricated thin films of 6,13-bis(triisopropylsilylethynyl) pentacene having non-equilibrium single-crystalline domains and an unprecedented average and maximum mobilities of 8.1±1.2 cm2 V-1 s -1 and 11 cm2 V-1 s-1. FLUENCE of organic semiconductors with non-equilibrium single-crystalline domains may find use in the fabrication of high-performance, large-area printed electronics. © 2013 Macmillan Publishers Limited. All rights reserved.

  13. Large scale fabrication of nitrogen vacancy-embedded diamond nanostructures for single-photon source applications

    Science.gov (United States)

    Jiang, Qianqing; Li, Wuxia; Tang, Chengchun; Chang, Yanchun; Hao, Tingting; Pan, Xinyu; Ye, Haitao; Li, Junjie; Gu, Changzhi

    2016-11-01

    Some color centers in diamond can serve as quantum bits which can be manipulated with microwave pulses and read out with laser, even at room temperature. However, the photon collection efficiency of bulk diamond is greatly reduced by refraction at the diamond/air interface. To address this issue, we fabricated arrays of diamond nanostructures, differing in both diameter and top end shape, with HSQ and Cr as the etching mask materials, aiming toward large scale fabrication of single-photon sources with enhanced collection efficiency made of nitrogen vacancy (NV) embedded diamond. With a mixture of O2 and CHF3 gas plasma, diamond pillars with diameters down to 45 nm were obtained. The top end shape evolution has been represented with a simple model. The tests of size dependent single-photon properties confirmed an improved single-photon collection efficiency enhancement, larger than tenfold, and a mild decrease of decoherence time with decreasing pillar diameter was observed as expected. These results provide useful information for future applications of nanostructured diamond as a single-photon source. Project supported by the National Key Research and Development Plan of China (Grant No. 2016YFA0200402), the National Natural Science Foundation of China (Grants Nos. 11574369, 11574368, 91323304, 11174362, and 51272278), and the FP7 Marie Curie Action (project No. 295208) sponsored by the European Commission.

  14. Design of an omnidirectional single-point photodetector for large-scale spatial coordinate measurement

    Science.gov (United States)

    Xie, Hongbo; Mao, Chensheng; Ren, Yongjie; Zhu, Jigui; Wang, Chao; Yang, Lei

    2017-10-01

    In high precision and large-scale coordinate measurement, one commonly used approach to determine the coordinate of a target point is utilizing the spatial trigonometric relationships between multiple laser transmitter stations and the target point. A light receiving device at the target point is the key element in large-scale coordinate measurement systems. To ensure high-resolution and highly sensitive spatial coordinate measurement, a high-performance and miniaturized omnidirectional single-point photodetector (OSPD) is greatly desired. We report one design of OSPD using an aspheric lens, which achieves an enhanced reception angle of -5 deg to 45 deg in vertical and 360 deg in horizontal. As the heart of our OSPD, the aspheric lens is designed in a geometric model and optimized by LightTools Software, which enables the reflection of a wide-angle incident light beam into the single-point photodiode. The performance of home-made OSPD is characterized with working distances from 1 to 13 m and further analyzed utilizing developed a geometric model. The experimental and analytic results verify that our device is highly suitable for large-scale coordinate metrology. The developed device also holds great potential in various applications such as omnidirectional vision sensor, indoor global positioning system, and optical wireless communication systems.

  15. GraMi: Generalized Frequent Pattern Mining in a Single Large Graph

    KAUST Repository

    Saeedy, Mohammed El

    2011-11-01

    Mining frequent subgraphs is an important operation on graphs. Most existing work assumes a database of many small graphs, but modern applications, such as social networks, citation graphs or protein-protein interaction in bioinformatics, are modeled as a single large graph. Interesting interactions in such applications may be transitive (e.g., friend of a friend). Existing methods, however, search for frequent isomorphic (i.e., exact match) subgraphs and cannot discover many useful patterns. In this paper the authors propose GRAMI, a framework that generalizes frequent subgraph mining in a large single graph. GRAMI discovers frequent patterns. A pattern is a graph where edges are generalized to distance-constrained paths. Depending on the definition of the distance function, many instantiations of the framework are possible. Both directed and undirected graphs, as well as multiple labels per vertex, are supported. The authors developed an efficient implementation of the framework that models the frequency resolution phase as a constraint satisfaction problem, in order to avoid the costly enumeration of all instances of each pattern in the graph. The authors also implemented CGRAMI, a version that supports structural and semantic constraints; and AGRAMI, an approximate version that supports very large graphs. The experiments on real data demonstrate that the authors framework is up to 3 orders of magnitude faster and discovers more interesting patterns than existing approaches.

  16. Methods for the preparation of large quantities of complex single-stranded oligonucleotide libraries.

    Science.gov (United States)

    Murgha, Yusuf E; Rouillard, Jean-Marie; Gulari, Erdogan

    2014-01-01

    Custom-defined oligonucleotide collections have a broad range of applications in fields of synthetic biology, targeted sequencing, and cytogenetics. Also, they are used to encode information for technologies like RNA interference, protein engineering and DNA-encoded libraries. High-throughput parallel DNA synthesis technologies developed for the manufacture of DNA microarrays can produce libraries of large numbers of different oligonucleotides, but in very limited amounts. Here, we compare three approaches to prepare large quantities of single-stranded oligonucleotide libraries derived from microarray synthesized collections. The first approach, alkaline melting of double-stranded PCR amplified libraries with a biotinylated strand captured on streptavidin coated magnetic beads results in little or no non-biotinylated ssDNA. The second method wherein the phosphorylated strand of PCR amplified libraries is nucleolyticaly hydrolyzed is recommended when small amounts of libraries are needed. The third method combining in vitro transcription of PCR amplified libraries to reverse transcription of the RNA product into single-stranded cDNA is our recommended method to produce large amounts of oligonucleotide libraries. Finally, we propose a method to remove any primer binding sequences introduced during library amplification.

  17. Single Crystal and Large Grain Niobium Research at Michigan State University

    Energy Technology Data Exchange (ETDEWEB)

    Compton, Chris; Aizaz, Ahmad; Baars, Derek; Bieler, Tom; Bierwagen, John; Bricker, Steve; Grimm, Terry; Hartung, Walter; Jiang, Hairong; Johnson, Matt; Popielarski, John; Saxton, Laura; Antoine, Claire; Wagner, Bob; Kneisel, Peter

    2007-09-01

    As Superconducting Radio Frequency (SRF) technology is used in more accelerator designs, research has focused on increasing the efficiency of these accelerators by pushing gradients and investigating cast reduction options. Today, most SRF structures are fabricated from high purity niobium. Over years of research, a material specification has been derived that defines a uniaxial, fine gain structure for SRF cavity fabrication. Most recently a push has been made to investigate the merits of using single or large grain niobium as a possible alternative to fine grain niobium. Michigan State University (MSU), in collaboration with Fermi National Accelerator Laboratory (FNAL) and Thomas Jefferson National Accelerator Facility (JLAB), is researching large grain niobium via cavity fabrication processes end testing, as well as exploring materials science issues associated with recrystallization and heat transfer. Single-cell 1.3 GHz (Beta=0.081) cavities made from both fine end large grain niobium were compared both in terms of fabrication procedures and performance. Two 7-cell cavities are currently being fabricated.

  18. Stem cell harvesting protocol research in autologous transplantation setting: Large volume vs. conventional cytapheresis

    Directory of Open Access Journals (Sweden)

    Balint Bela

    2008-01-01

    Full Text Available Background/Aim. The use of peripheral blood as a source of hematopoietic stem cells (SCs is progressively increasing and has nearly supplanted bone marrow transplantation. Interpatient variability in the degree and kinetics of SC mobilization into peripheral blood is an expected event after conventional chemotherapy-based treatment, followed by sequential administration of recombinant granulocyte-colony- stimulating factor (rHu-CSF. In this study, specific factors associated with the application of two different SC-harvesting approaches, including the use of large volume leukapheresis (LVL vs. repetitive conventional apheresis (RCA, were analyzed. The basic goal of the study was to evaluate the influence of apheresis protocol (collection timing, processed blood volume and cell yield upon the clinical outcome of transplantation. Methods. Results obtained by LVL (76 pts and RCA (20 pts - control group were compared. The SC mobilizing regimen used was cyclophosphamide (4-7 g/m2 or polychemotherapy and rHuG-CSF 10-16 μg/kg of body mess (bm per day. Cell harvesting was performed using COBE-Spectra (Caridian-BCT, USA. The volume of processed blood in LVL setting was ≥ 3.5 - fold of the patient's circulating blood quantity (ranged from 12.7 to 37.8 l. All patients tolerated well the use of intensive treatment, without any side or adverse effects. Our original controlled-rate cryopreservation was carried out with 10% dimethyl sulfoxide (DMSO using Planer R203/200R or Planer 560-16 equipments (Planer Products Ltd, UK. Total nucleated cell (NC and mononuclear cell (MNC counts were examined by flow cytometry (Advia-2120 Bayer, Germany; Technicon H-3 System, USA. The CD34+ cell surface antigen was investigated by the EPICS XL-MCL device (Coulter, Germany. Results. Performing LVL-apheresis, high-level MNC and CD34+ cell yields (7.6±4.6 × 108/kg bm and 11.8±6.5 × 106/kg bm, respectively were obtained. As a result, rapid hematopoietic reconstitution

  19. Design of a Large Single-Aperture Dipole Magnet for HL-LHC Upgrade

    CERN Document Server

    Qingjin, Xu; Iio, Masami; Ogitsu, Toru; Sasaki, Kenichi; Yamamoto, Akira; Todesco, Ezio

    2013-01-01

    An upgrade of the low-beta insertion system for the ATLAS and Compact Muon Solenoid experiments is proposed in the high luminosity Large Hadron Collider upgrade project. It includes final beam focusing quadrupoles, beam separation and recombination dipoles, and larger aperture matching section quadrupoles. KEK is in charge of the conceptual design of the large aperture separation dipole D1. The latest design parameters are a main field of ~ 5 T at 1.9 K with Nb-Ti superconducting technology, a coil aperture of 160 mm, and a cos-theta one-layer coil with Large Hadron Collider dipole cable. Because the new D1 is expected to be operated in a very high radiation environment, radiation resistance and a cooling scheme are being carefully considered. The collaring-yoke structure is adopted to provide the mechanical support for the single-layer Nb-Ti coil. We summarize the design study of this magnet, including i) the very large iron saturation effect on field quality due to the large aperture and limited size of the...

  20. Carcinoma of the large bowel after a single massive dose of radiation in healthy teenagers

    Energy Technology Data Exchange (ETDEWEB)

    Rotmensch, S.; Avigad, I.; Soffer, E.E.; Horowitz, A.; Bar-Meir, S.; Confino, R.; Czerniak, A.; Wolfstein, I.

    1986-02-15

    Three healthy teenagers were exposed to a single pelvic x-ray irradiation as part of sterilization experiments performed in the Auschwitz concentration camp in 1943. Single and multiple carcinomas of the colon and rectum developed 40 years later in the radiation field. Histologic examination of surgical specimens revealed severe radiation-induced changes in all layers of tumor-adjacent areas. In contrast to previous reports of radiation-induced large bowel cancers, these women had not undergone repeated courses of radiation, had no known co-existing disease that might raise the risk for colonic and rectal malignancies, and had an extremely long and remarkably similar latency period. These cases emphasize the need for long-term surveillance in previously radiated patients. Since thousands of teenagers were subjected to similar sterilization experiments, awareness of this association might help in the early diagnosis of additional cases.

  1. Controlling Fundamental Fluctuations for Reproducible Growth of Large Single-Crystal Graphene.

    Science.gov (United States)

    Guo, Wei; Wu, Bin; Wang, Shuai; Liu, Yunqi

    2018-02-27

    The controlled growth of graphene by the chemical vapor deposition method is vital for its various applications; however, the reproducibility remains a great challenge. Here, using single-crystal graphene growth on a Cu surface as a model system, we demonstrate that a trace amount of H 2 O and O 2 impurity gases in the reaction chamber is key for the large fluctuation of graphene growth. By precisely controlling their parts per million level concentrations, centimeter-sized single-crystal graphene is obtained in a reliable manner with a maximum growth rate up to 190 μm min -1 . The roles of oxidants are elucidated as an effective modulator for both graphene nucleation density and growth rate. This control is more fundamental for reliable growth of graphene beyond previous findings and is expected to be useful for the growth of various 2D materials that are also sensitive to trace oxidant impurities.

  2. Large single crystals of graphene on melted copper using chemical vapor deposition.

    Science.gov (United States)

    Wu, Yimin A; Fan, Ye; Speller, Susannah; Creeth, Graham L; Sadowski, Jerzy T; He, Kuang; Robertson, Alex W; Allen, Christopher S; Warner, Jamie H

    2012-06-26

    A simple method is presented for synthesizing large single crystal graphene domains on melted copper using atmospheric pressure chemical vapor deposition (CVD). This is achieved by performing the reaction above the melting point of copper (1090 °C) and using a molybdenum or tungsten support to prevent balling of the copper from dewetting. By controlling the amount of hydrogen during growth, individual single crystal domains of monolayer graphene greater than 200 μm are produced within a continuous film. Stopping growth before a complete film is formed reveals individual hexagonal domains of graphene that are epitaxially aligned in their orientation. Angular resolved photoemission spectroscopy is used to show that the graphene grown on copper exhibits a linear dispersion relationship and no sign of doping. HRTEM and electron diffraction reveal a uniform high quality crystalline atomic structure of monolayer graphene.

  3. A Parallel Approach for Frequent Subgraph Mining in a Single Large Graph Using Spark

    Directory of Open Access Journals (Sweden)

    Fengcai Qiao

    2018-02-01

    Full Text Available Frequent subgraph mining (FSM plays an important role in graph mining, attracting a great deal of attention in many areas, such as bioinformatics, web data mining and social networks. In this paper, we propose SSiGraM (Spark based Single Graph Mining, a Spark based parallel frequent subgraph mining algorithm in a single large graph. Aiming to approach the two computational challenges of FSM, we conduct the subgraph extension and support evaluation parallel across all the distributed cluster worker nodes. In addition, we also employ a heuristic search strategy and three novel optimizations: load balancing, pre-search pruning and top-down pruning in the support evaluation process, which significantly improve the performance. Extensive experiments with four different real-world datasets demonstrate that the proposed algorithm outperforms the existing GraMi (Graph Mining algorithm by an order of magnitude for all datasets and can work with a lower support threshold.

  4. Carcinoma of the large bowel after a single massive dose of radiation in healthy teenagers

    International Nuclear Information System (INIS)

    Rotmensch, S.; Avigad, I.; Soffer, E.E.; Horowitz, A.; Bar-Meir, S.; Confino, R.; Czerniak, A.; Wolfstein, I.

    1986-01-01

    Three healthy teenagers were exposed to a single pelvic x-ray irradiation as part of sterilization experiments performed in the Auschwitz concentration camp in 1943. Single and multiple carcinomas of the colon and rectum developed 40 years later in the radiation field. Histologic examination of surgical specimens revealed severe radiation-induced changes in all layers of tumor-adjacent areas. In contrast to previous reports of radiation-induced large bowel cancers, these women had not undergone repeated courses of radiation, had no known co-existing disease that might raise the risk for colonic and rectal malignancies, and had an extremely long and remarkably similar latency period. These cases emphasize the need for long-term surveillance in previously radiated patients. Since thousands of teenagers were subjected to similar sterilization experiments, awareness of this association might help in the early diagnosis of additional cases

  5. Tidal Volume Single Breath Washout of Two Tracer Gases - A Practical and Promising Lung Function Test

    Science.gov (United States)

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-01-01

    Background Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF6) and helium (He) using an ultrasonic flowmeter (USFM). Methods The tracer gas mixture contained 5% SF6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. Results USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. Conclusion The USFM accurately measured relative changes in SF6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF6 and He washout patterns during tidal breathing. PMID:21423739

  6. Physical properties and structure of large grain/single crystal niobium for superconducting RF cavities

    International Nuclear Information System (INIS)

    Ermakov, A; Jelezov, I; Singer, X; Singer, W; Wen, H; Spiwek, M; Viswanathan, G B; Levit, V; Fraser, H L

    2008-01-01

    The R and D program on superconducting cavities fabricated from electron beam melted large grain/single crystal (LG/SC) niobium discs explores it's potential for production of approximately 1000 cavities for the European XFEL. Thermal, electrical, mechanical properties, crystal orientation and structure are investigated with the aim to make the fabrication procedure more efficient. In opposite to fine grain niobium the thermal conductivity of LG/SC has a pronounced maximum at 2K. Calculation found a correlation between thermal conductivity enhancement and phonon scattering at the grain boundaries. Detected enhancement is very susceptible to plastic deformation that can cause the complete elimination of the low temperature peak. The final annealing at 800 deg. C of cavities made from large grain niobium is necessary for hydrogen outgassing, as well as for the thermal conductivity enhancement due to stress relaxation and recovery of crystal defects introduced at the cavity fabrication. The effects of annealing temperature up to 1200 deg. C, heating rate, and holding time on the structure recovery after rolling are also established. Total elongation at the uniaxial tensile tests for LG is very high (50-110%) and depends significantly on the load direction, because only very few grains are in the gage length. The elongation after fracture by bi-axial testing (bulging test) for LG is lower (<15%) yet sufficient for deep drawing of half-cells. Metallographic investigation of and electron beam welding tests on, niobium single crystals show that an appropriate disc enlargement and annealing can be done without destruction of the single crystal. These tests showed that a cavity can be produced without grain boundaries even in the welding area. On base of the results a fabrication method of single crystal cavities is proposed

  7. Grey matter volume in a large cohort of MS patients: relation to MRI parameters and disability

    NARCIS (Netherlands)

    Roosendaal, S.D.; Bendfeldt, K.; Vrenken, H.; Polman, C.H.; Borgwardt, S.; Radue, E.W.; Kappos, L.; Pelletier, D.; Hauser, S.L.; Matthews, P.M.; Barkhof, F.; Geurts, J.J.G.

    2011-01-01

    Background: Although grey matter damage in multiple sclerosis is currently recognized, determinants of grey matter volume and its relationship with disability are not yet clear.Objectives: The Objectives of the study were to measure grey and white matter volumes across different disease phenotypes;

  8. Single-mode ytterbium-doped large-mode-area photonic bandgap rod fiber amplifier

    DEFF Research Database (Denmark)

    Alkeskjold, Thomas Tanggaard; Scolari, Lara; Broeng, Jes

    2011-01-01

    Enabling Single-Mode (SM) operation in Large-Mode-Area (LMA) fiber amplifiers and lasers is critical, since a SM output ensures high beam quality and excellent pointing stability. In this paper, we demonstrate and test a new design approach for achieving SM LMA rod fibers by using a photonic...... bandgap structure. The structure allows resonant coupling of higher-order modes from the core and acts as a spatially Distributed Mode Filter (DMF). With this approach, we demonstrate passive SM performance in an only ~50cm long and straight ytterbium-doped rod fiber. The amplifier has a mode field...

  9. Laparoendoscopic Single-Site Surgery (LESS for a Large Ovarian Tumour: First Clinical Case Report

    Directory of Open Access Journals (Sweden)

    Yao Dong Chua

    2011-01-01

    Main Outcome Measure(s. Conversion to standard laparoscopic technique or laparotomy, estimated blood loss, operative time , extent of scarring, occurrence of intra- and perioperative surgical complications, technical adequacy, and clinical outcome. Result(s. No conversion to standard laparoscopic technique or laparotomy, and no intraoperative or postoperative complications were observed. Total operative time was 99 minutes. The patient was discharged home on postoperative day one. Conclusion(s. Laparoendoscopic single-site bilateral salpingo-oophorectomy of a large ovarian tumour is feasible with standard laparoscopic instruments. It is safe and effective, with good results in terms of excellent cosmesis and minimal postoperative pain.

  10. Control Algorithms for Large-scale Single-axis Photovoltaic Trackers

    Directory of Open Access Journals (Sweden)

    Dorian Schneider

    2012-01-01

    Full Text Available The electrical yield of large-scale photovoltaic power plants can be greatly improved by employing solar trackers. While fixed-tilt superstructures are stationary and immobile, trackers move the PV-module plane in order to optimize its alignment to the sun. This paper introduces control algorithms for single-axis trackers (SAT, including a discussion for optimal alignment and backtracking. The results are used to simulate and compare the electrical yield of fixed-tilt and SAT systems. The proposed algorithms have been field tested, and are in operation in solar parks worldwide.

  11. Universal large deviations for the tagged particle in single-file motion.

    Science.gov (United States)

    Hegde, Chaitra; Sabhapandit, Sanjib; Dhar, Abhishek

    2014-09-19

    We consider a gas of point particles moving in a one-dimensional channel with a hard-core interparticle interaction that prevents particle crossings--this is called single-file motion. Starting from equilibrium initial conditions we observe the motion of a tagged particle. It is well known that if the individual particle dynamics is diffusive, then the tagged particle motion is subdiffusive, while for ballistic particle dynamics, the tagged particle motion is diffusive. Here we compute the exact large deviation function for the tagged particle displacement and show that this is universal, independent of the individual dynamics.

  12. Addressing challenges in bar-code scanning of large-volume infusion bags.

    Science.gov (United States)

    Raman, Kirthana; Heelon, Mark; Kerr, Gary; Higgins, Thomas L

    2011-08-01

    A hospital pharmacy's efforts to identify and address challenges with bedside scanning of bar codes on large-volume parenteral (LVP) infusion bags are described. Bar-code-assisted medication administration (BCMA) has been shown to reduce medication errors and improve patient safety. After the pilot implementation of a BCMA system and point-of-care scanning procedures at a medical center's intensive care unit, it was noted that nurses' attempted bedside scans of certain LVP bags for product identification purposes often were not successful. An investigation and root-cause analysis, including observation of nurses' scanning technique by a multidisciplinary team, determined that the scanning failures stemmed from the placement of two bar-code imprints-one with the product identification code and another, larger imprint with the expiration date and lot number-adjacently on the LVP bags. The nursing staff was educated on a modified scanning technique, which resulted in significantly improved success rates in the scanning of the most commonly used LVP bags. Representatives of the LVP bag manufacturer met with hospital staff to discuss the problem and corrective measures. As part of a subsequent infusion bag redesign, the manufacturer discontinued the use of the bar-code imprint implicated in the scanning failures. Failures in scanning LVP bags were traced to problematic placement of bar-code imprints on the bags. Interdisciplinary collaboration, consultation with the bag manufacturer, and education of the nursing and pharmacy staff resulted in a reduction in scanning failures and the manufacturer's removal of one of the bar codes from its LVP bags.

  13. Type IIB orientifolds, D-brane instantons and the large volume scenario

    Energy Technology Data Exchange (ETDEWEB)

    Plauschinn, Erik

    2009-07-28

    This thesis is concerned with a branch of research in String Theory called String Phenomenology which aims for a better understanding of the connection between String Theory and Particle Physics. In particular, in this work we cover three topics which are important in order to establish this connection. The first topic is about String Theory model building in the context of so-called type IIB orientifolds with orientifold three- and seven-planes. After giving a brief overview, we work out in detail an important consistency condition for String Theory constructions, the so-called tadpole cancellation condition, and we verify explicitly that chiral anomalies are cancelled via the generalised Green-Schwarz mechanism. The second topic is concerned with so-called D-brane instantons which are nonperturbative effects in type II String Theory constructions. We recall the instanton calculus for such configurations, we derive the so-called A eck-Dine-Seiberg superpotential in String Theory and we develop an important constraint, a chiral zero-mode constraint, for instanton contributions in the presence of a realistic Particle Physics sector. The third topic is about moduli stabilisation in type IIB string compactifications. More concretely, we review the so-called KKLT as well as Large Volume Scenario, and we construct and study a model for the latter scenario where the constraint mentioned above has been taken into account explicitly. Although the three topics studied in this thesis are slightly different in nature, there is nevertheless a complex interplay between them with many interrelations. In order to uncover these connections, a detailed study of each individual subject has been performed which has led to new results such as the chiral zero-mode constraint. (orig.)

  14. Stability and visual compatibility of bretylium tosylate with selected large-volume parenterals and additives.

    Science.gov (United States)

    Perentesis, G P; Piltz, G W; Kirshcenbaum, H L; Navalakha, P; Aronoff, W; Cutie, A J

    1983-06-01

    The stability of bretylium tosylate when mixed with large-volume parenteral (LVP) solutions was assessed over a four-week period, and the compatibility of bretylium tosylate when mixed with eight frequently used drugs was evaluated. Bretylium tosylate admixtures of approximately 1 mg/ml were prepared in both polyvinyl chloride (PVC) bags and glass bottles of 5% dextrose injection, 0.9% sodium chloride injection, and lactated Ringer's injection. The admixtures were examined visually and stored for four weeks at 25 +/- 0.5 degree C under fluorescent light. The concentrations of bretylium tosylate were determined spectrophotometrically at times 0.25, 0.5, 1, 3, 8, 24, and 48 hours and twice weekly thereafter for four weeks. Spectrophotometric assays were confirmed with high-pressure liquid chromatography. Admixtures of bretylium tosylate were prepared with aminophylline, calcium gluconate, digoxin, regular insulin, lidocaine hydrochloride, phenytoin sodium, procainamide hydrochloride, and quinidine gluconate in 5% dextrose injection and 0.9% sodium chloride injection. The admixtures were examined visually for 48 hours. The concentration of bretylium tosylate did not change appreciably during the four-week study period. There were no signs of haze, precipitation, color change, or evolution of gas. There were no apparent differences in stability when comparing the glass with the PVC containers. Bretylium tosylate was also found to be compatible with all the additives tested except phenytoin sodium; a precipitate formed immediately when the latter drug was added to the bretylium tosylate solution. Bretylium tosylate was stable for four weeks in the LVP solutions studied in both glass and PVC containers. The admixtures of bretylium sodium with the other drugs were all visually compatible except those containing phenytoin sodium.

  15. Evaluation of single right atrial volume and function with magnetic resonance imaging in children with hypoplastic left heart

    International Nuclear Information System (INIS)

    Vijarnsorn, Chodchanok; Myers, Kimberley; Patton, David J.; Noga, Michelle; Crawley, Cinzia; Tham, Edythe

    2016-01-01

    Standardized methods to evaluate atrial properties in single ventricles are lacking. To determine the feasibility of quantifying right atrial volumes and function in hypoplastic left heart using MRI. We studied 15 infants with hypoplastic left heart prior to Glenn surgery (mean age 4.2 months [standard deviation 0.3]) who underwent cardiac MRI with evaluation of atrial volumes and emptying fraction using monoplane two-chamber, monoplane four-chamber, and biplane methods, all of which were compared to the atrial short-axial oblique stack method. We compared atrial end-diastolic volume, end-systolic volume and emptying fraction among these methods. We analyzed reproducibility of the methods using Bland-Altman plots. Both four-chamber and biplane methods showed high correlations for atrial end-diastolic volume (r = 0.7 and r = 0.8, respectively; P < 0.01) and end-systolic volume (r = 0.8 and r = 0.9, respectively; P < 0.01) with small mean differences (-0.2 ± 2.9 standard deviation [SD] ml and -0.8 ± 1.6 ml, respectively, for atrial end-diastolic volume and -0.8 ± 1.5 ml and -0.9 ± 0.9 ml, respectively, for atrial end-systolic volume). The short-axial oblique method was the most reproducible, followed by the four-chamber method. MRI assessment of atrial volume and function is feasible in hypoplastic left heart and might provide further insight into single-ventricle mechanics. (orig.)

  16. Evaluation of single right atrial volume and function with magnetic resonance imaging in children with hypoplastic left heart

    Energy Technology Data Exchange (ETDEWEB)

    Vijarnsorn, Chodchanok [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada); Mahidol University, Siriraj Hospital, Bangkok (Thailand); Myers, Kimberley; Patton, David J. [Alberta Children' s Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Department of Pediatrics, Calgary, AB (Canada); Noga, Michelle; Crawley, Cinzia; Tham, Edythe [University of Alberta, Faculty of Medicine and Dentistry, Stollery Children' s Hospital, Edmonton, AB (Canada)

    2016-06-15

    Standardized methods to evaluate atrial properties in single ventricles are lacking. To determine the feasibility of quantifying right atrial volumes and function in hypoplastic left heart using MRI. We studied 15 infants with hypoplastic left heart prior to Glenn surgery (mean age 4.2 months [standard deviation 0.3]) who underwent cardiac MRI with evaluation of atrial volumes and emptying fraction using monoplane two-chamber, monoplane four-chamber, and biplane methods, all of which were compared to the atrial short-axial oblique stack method. We compared atrial end-diastolic volume, end-systolic volume and emptying fraction among these methods. We analyzed reproducibility of the methods using Bland-Altman plots. Both four-chamber and biplane methods showed high correlations for atrial end-diastolic volume (r = 0.7 and r = 0.8, respectively; P < 0.01) and end-systolic volume (r = 0.8 and r = 0.9, respectively; P < 0.01) with small mean differences (-0.2 ± 2.9 standard deviation [SD] ml and -0.8 ± 1.6 ml, respectively, for atrial end-diastolic volume and -0.8 ± 1.5 ml and -0.9 ± 0.9 ml, respectively, for atrial end-systolic volume). The short-axial oblique method was the most reproducible, followed by the four-chamber method. MRI assessment of atrial volume and function is feasible in hypoplastic left heart and might provide further insight into single-ventricle mechanics. (orig.)

  17. Large Out-of-Plane Displacement Bistable Electromagnetic Microswitch on a Single Wafer.

    Science.gov (United States)

    Miao, Xiaodan; Dai, Xuhan; Huang, Yi; Ding, Guifu; Zhao, Xiaolin

    2016-05-05

    This paper presents a bistable microswitch fully batch-fabricated on a single glass wafer, comprising of a microactuator, a signal transformer, a microspring and a permanent magnet. The bistable mechanism of the microswitch with large displacement of 160 μm depends on the balance of the magnetic force and elastic force. Both the magnetic force and elastic force were optimized by finite-element simulation to predict the reliable of the device. The prototype was fabricated and characterized. By utilizing thick laminated photoresist sacrificial layer, the large displacement was obtained to ensure the insulation of the microswitch. The testing results show that the microswitch realized the bistable mechanism at a 3-5 V input voltage and closed in 0.96 ms, which verified the simulation.

  18. Human Exploration Initiatives at EAC: Spaceship EAC and the Development of Large-Volume Lunar Regolith Simulant for LUNA

    Science.gov (United States)

    Nash, V. E.; Cowley, A.; Fateri, M.; Coene, S.; Siarov, S.; Cristoforetti, S.

    2017-09-01

    In order to address analogue capability gaps previously identified by ESA GSP studies, EAC has embarked on a number of exploration enabling initiatives at the centre in Cologne, Germany. Herein, preliminary results of two of these projects are presented; the Spaceship EAC initiative and EAC-1, a large-volume lunar regolith simulant for the LUNA facility.

  19. The orthogonal in-situ machining of single and polycrystalline aluminum and copper, volume 1

    Science.gov (United States)

    Cohen, P. H.

    1982-05-01

    Metal cutting is a unique deformation process characterized by large strains, exceptionally high strain rates and few constraints to the deformation. These factors, along with the difficulty of directly measuring the shear angle, make chip formation difficult to model and understand. One technique for skirting the difficulty of post mortem chip measurement is to perform a cutting experiment dynamically in a scanning electron microscope. The performance of the in-situ experiment with full instrumentation allows for component force measurement, orientation measurement (on a round single crystal disk) and a timing device, all superimposed below the deformation on the TV monitor and recorded for future viewing. This allows the sher angle to be directly measured for the screen along with the other needed information.

  20. Reassessing breeding investment in birds: class-wide analysis of clutch volume reveals a single outlying family.

    Science.gov (United States)

    Watson, David M; Anderson, Susan E; Olson, Valerie

    2015-01-01

    Reproductive investment is typically considered in terms of size and number of propagules produced. Compared with a thorough understanding of the overall patterns and ecological correlates of avian clutch size, egg size has received less attention and the total effort invested in laying a clutch of eggs is rarely considered. We used clutch volume as an alternative estimate of reproductive investment and present the first class-level analysis of clutch volume in birds using 1,364 randomly-selected species in 204 families. The relationship between body mass and egg volume was very strong (r2 = 0.946), validating previous studies identifying four families (Apterygidae, Pelecanoidiididae, Sternidae and Dromadidiae) with disproportionately large eggs. Clutch volume was also closely related to body mass (r2 = 0.909) and all but one of the taxa with disproportionately large eggs conformed to the overall relationship, their greater egg dimensions compensated by diminished clutch size. The only family which departed significantly from the relationship between body mass and clutch volume was the mound builders (Megapodiidae)-the only group of birds that do not rely on body heat for incubation. Although previously known for laying large clutches of large eggs containing disproportionately large yolks, the remarkable investment of megapodes in reproduction (more than seven times greater than other birds of comparable mass) has been hitherto overlooked. We consider the evolutionary basis and ecological implications of this finding, suggesting that energetic costs associated with incubation act as an upper limit on reproductive output of other birds. We recommend clutch volume as a sensitive, fine-grained measure of reproductive effort for research at a wide range of scales and advocate further analysis of ecological correlates of clutch volume in birds and amniotes generally.

  1. Large curvature and background scale independence in single-metric approximations to asymptotic safety

    Energy Technology Data Exchange (ETDEWEB)

    Morris, Tim R. [STAG Research Centre & Department of Physics and Astronomy, University of Southampton,Highfield, Southampton, SO17 1BJ (United Kingdom)

    2016-11-25

    In single-metric approximations to the exact renormalization group (RG) for quantum gravity, it has been not been clear how to treat the large curvature domain beyond the point where the effective cutoff scale k is less than the lowest eigenvalue of the appropriate modified Laplacian. We explain why this puzzle arises from background dependence, resulting in Wilsonian RG concepts being inapplicable. We show that when properly formulated over an ensemble of backgrounds, the Wilsonian RG can be restored. This in turn implies that solutions should be smooth and well defined no matter how large the curvature is taken. Even for the standard single-metric type approximation schemes, this construction can be rigorously derived by imposing a modified Ward identity (mWI) corresponding to rescaling the background metric by a constant factor. However compatibility in this approximation requires the space-time dimension to be six. Solving the mWI and flow equation simultaneously, new variables are then derived that are independent of overall background scale.

  2. Synthesis and characterization of p-type boron-doped IIb diamond large single crystals

    International Nuclear Information System (INIS)

    Li Shang-Sheng; Li Xiao-Lei; Su Tai-Chao; Jia Xiao-Peng; Ma Hong-An; Huang Guo-Feng; Li Yong

    2011-01-01

    High-quality p-type boron-doped IIb diamond large single crystals are successfully synthesized by the temperature gradient method in a china-type cubic anvil high-pressure apparatus at about 5.5 GPa and 1600 K. The morphologies and surface textures of the synthetic diamond crystals with different boron additive quantities are characterized by using an optical microscope and a scanning electron microscope respectively. The impurities of nitrogen and boron in diamonds are detected by micro Fourier transform infrared technique. The electrical properties including resistivities, Hall coefficients, Hall mobilities and carrier densities of the synthesized samples are measured by a four-point probe and the Hall effect method. The results show that large p-type boron-doped diamond single crystals with few nitrogen impurities have been synthesized. With the increase of quantity of additive boron, some high-index crystal faces such as {113} gradually disappear, and some stripes and triangle pits occur on the crystal surface. This work is helpful for the further research and application of boron-doped semiconductor diamond. (cross-disciplinary physics and related areas of science and technology)

  3. GRAMI: Frequent subgraph and pattern mining in a single large graph

    KAUST Repository

    Elseidy, M.

    2014-01-01

    Mining frequent subgraphs is an important operation on graphs; it is defined as finding all subgraphs that appear frequently in a database according to a given frequency threshold. Most existing work assumes a database of many small graphs, but modern applications, such as social networks, citation graphs, or proteinprotein interactions in bioinformatics, are modeled as a single large graph. In this paper we present GRAMI, a novel framework for frequent subgraph mining in a single large graph. GRAMI undertakes a novel approach that only finds the minimal set of instances to satisfy the frequency threshold and avoids the costly enumeration of all instances required by previous approaches. We accompany our approach with a heuristic and optimizations that significantly improve performance. Additionally, we present an extension of GRAMI that mines frequent patterns. Compared to subgraphs, patterns offer a more powerful version of matching that captures transitive interactions between graph nodes (like friend of a friend) which are very common in modern applications. Finally, we present CGRAMI, a version supporting structural and semantic constraints, and AGRAMI, an approximate version producing results with no false positives. Our experiments on real data demonstrate that our framework is up to 2 orders of magnitude faster and discovers more interesting patterns than existing approaches. 2014 VLDB Endowment.

  4. Techniques for extracting single-trial activity patterns from large-scale neural recordings

    Science.gov (United States)

    Churchland, Mark M; Yu, Byron M; Sahani, Maneesh; Shenoy, Krishna V

    2008-01-01

    Summary Large, chronically-implanted arrays of microelectrodes are an increasingly common tool for recording from primate cortex, and can provide extracellular recordings from many (order of 100) neurons. While the desire for cortically-based motor prostheses has helped drive their development, such arrays also offer great potential to advance basic neuroscience research. Here we discuss the utility of array recording for the study of neural dynamics. Neural activity often has dynamics beyond that driven directly by the stimulus. While governed by those dynamics, neural responses may nevertheless unfold differently for nominally identical trials, rendering many traditional analysis methods ineffective. We review recent studies – some employing simultaneous recording, some not – indicating that such variability is indeed present both during movement generation, and during the preceding premotor computations. In such cases, large-scale simultaneous recordings have the potential to provide an unprecedented view of neural dynamics at the level of single trials. However, this enterprise will depend not only on techniques for simultaneous recording, but also on the use and further development of analysis techniques that can appropriately reduce the dimensionality of the data, and allow visualization of single-trial neural behavior. PMID:18093826

  5. Effect of a single large impact on the coupled atmosphere-interior evolution of Venus

    Science.gov (United States)

    Gillmann, Cédric; Golabek, Gregor J.; Tackley, Paul J.

    2016-04-01

    We investigate the effect of a single large impact either during the Late Veneer or Late Heavy Bombardment on the evolution of the mantle and atmosphere of Venus. We use a coupled interior/exterior numerical code based on StagYY developed in Gillmann and Tackley (Gillmann, C., Tackley, P.J. [2014]. J. Geophys. Res. 119, 1189-1217). Single vertical impacts are simulated as instantaneous events affecting both the atmosphere and mantle of the planet by (i) eroding the atmosphere, causing atmospheric escape and (ii) depositing energy in the crust and mantle of the planet. The main impactor parameters include timing, size/mass, velocity and efficiency of energy deposition. We observe that impact erosion of the atmosphere is a minor effect compared to melting and degassing triggered by energy deposition in the mantle and crust. We are able to produce viable pathways that are consistent with present-day Venus, especially considering large Late Veneer Impacts. Small collisions (global event and can be responsible for volcanic events focused at the impact location and near the antipode. Depending on the timing of the impact, it can also have major consequences for the long-term evolution of the planet and its surface conditions by either (i) efficiently depleting the upper mantle of the planet, leading to the early loss of its water or (ii) imposing a volatile-rich and hot atmosphere for billions of years.

  6. Large-Area WS2 Film with Big Single Domains Grown by Chemical Vapor Deposition

    Science.gov (United States)

    Liu, Pengyu; Luo, Tao; Xing, Jie; Xu, Hong; Hao, Huiying; Liu, Hao; Dong, Jingjing

    2017-10-01

    High-quality WS2 film with the single domain size up to 400 μm was grown on Si/SiO2 wafer by atmospheric pressure chemical vapor deposition. The effects of some important fabrication parameters on the controlled growth of WS2 film have been investigated in detail, including the choice of precursors, tube pressure, growing temperature, holding time, the amount of sulfur powder, and gas flow rate. By optimizing the growth conditions at one atmospheric pressure, we obtained tungsten disulfide single domains with an average size over 100 μm. Raman spectra, atomic force microscopy, and transmission electron microscopy provided direct evidence that the WS2 film had an atomic layer thickness and a single-domain hexagonal structure with a high crystal quality. And the photoluminescence spectra indicated that the tungsten disulfide films showed an evident layer-number-dependent fluorescence efficiency, depending on their energy band structure. Our study provides an important experimental basis for large-area, controllable preparation of atom-thick tungsten disulfide thin film and can also expedite the development of scalable high-performance optoelectronic devices based on WS2 film.

  7. A large collapsed-state RNA can exhibit simple exponential single-molecule dynamics.

    Science.gov (United States)

    Smith, Glenna J; Lee, Kang Taek; Qu, Xiaohui; Xie, Zheng; Pesic, Jelena; Sosnick, Tobin R; Pan, Tao; Scherer, Norbert F

    2008-05-09

    The process of large RNA folding is believed to proceed from many collapsed structures to a unique functional structure requiring precise organization of nucleotides. The diversity of possible structures and stabilities of large RNAs could result in non-exponential folding kinetics (e.g. stretched exponential) under conditions where the molecules have not achieved their native state. We describe a single-molecule fluorescence resonance energy transfer (FRET) study of the collapsed-state region of the free energy landscape of the catalytic domain of RNase P RNA from Bacillus stearothermophilus (C(thermo)). Ensemble measurements have shown that this 260 residue RNA folds cooperatively to its native state at >or=1 mM Mg(2+), but little is known about the conformational dynamics at lower ionic strength. Our measurements of equilibrium conformational fluctuations reveal simple exponential kinetics that reflect a small number of discrete states instead of the expected inhomogeneous dynamics. The distribution of discrete dwell times, collected from an "ensemble" of 300 single molecules at each of a series of Mg(2+) concentrations, fit well to a double exponential, which indicates that the RNA conformational changes can be described as a four-state system. This finding is somewhat unexpected under [Mg(2+)] conditions in which this RNA does not achieve its native state. Observation of discrete well-defined conformations in this large RNA that are stable on the seconds timescale at low [Mg(2+)] (<0.1 mM) suggests that even at low ionic strength, with a tremendous number of possible (weak) interactions, a few critical interactions may produce deep energy wells that allow for rapid averaging of motions within each well, and yield kinetics that are relatively simple.

  8. Process Improvement to Enhance Quality in a Large Volume Labor and Birth Unit.

    Science.gov (United States)

    Bell, Ashley M; Bohannon, Jessica; Porthouse, Lisa; Thompson, Heather; Vago, Tony

    using the Lean process, frontline clinicians identified areas that needed improvement, developed and implemented successful strategies that addressed each gap, and enhanced the quality and safety of care for a large volume perinatal service.

  9. Temperature monitoring in large volume spread footing foundations: case study "Parque da Cidade" - São Paulo

    Directory of Open Access Journals (Sweden)

    D. Couto

    Full Text Available ABSTRACT In recent years, the construction of foundation elements from large-volume reinforced concrete is becoming increasingly common. This implies a potential increase in the risk of cracks of thermal origin, due to the heat of hydration of cement. Under these circumstances, these concrete elements need to be treated using the mass concrete theory, widespread in dam construction, but little used when designing buildings. This paper aims to present a case study about the procedures and problems involved in the construction of a spread footing with a volume of approximately 800m³ designed for the foundation of a shopping center in São Paulo, Brazil.

  10. Forced transport of thermal energy in magmatic and phreatomagmatic large volume ignimbrites: Paleomagnetic evidence from the Colli Albani volcano, Italy

    Science.gov (United States)

    Trolese, Matteo; Giordano, Guido; Cifelli, Francesca; Winkler, Aldo; Mattei, Massimo

    2017-11-01

    Few studies have detailed the thermal architecture of large-volume pyroclastic density current deposits, although such work has a clear importance for understanding the dynamics of eruptions of this magnitude. Here we examine the temperature of emplacement of large-volume caldera-forming ignimbrites related to magmatic and phreatomagmatic eruptions at the Colli Albani volcano, Italy, by using thermal remanent magnetization analysis on both lithic and juvenile clasts. Results show that all the magmatic ignimbrites were deposited at high temperature, between the maximum blocking temperature of the magnetic carrier (600-630 °C) and the glass transition temperature (about 710 °C). Temperature estimations for the phreatomagmatic ignimbrite range between 200 and 400 °C, with most of the clasts emplaced between 200 and 320 °C. Because all the investigated ignimbrites, magmatic and phreatomagmatic, share similar magma composition, volume and mobility, we attribute the temperature difference to magma-water interaction, highlighting its pronounced impact on thermal dissipation, even in large-volume eruptions. The homogeneity of the deposit temperature of each ignimbrite across its areal extent, which is maintained across topographic barriers, suggests that these systems are thermodynamically isolated from the external environment for several tens of kilometers. Based on these findings, we propose that these large-volume ignimbrites are dominated by the mass flux, which forces the lateral transport of mass, momentum, and thermal energy for distances up to tens of kilometers away from the vent. We conclude that spatial variation of the emplacement temperature can be used as a proxy for determining the degree of forced-convection flow.

  11. Radiobiological restrictions and tolerance doses of repeated single-fraction hdr-irradiation of intersecting small liver volumes for recurrent hepatic metastases

    Directory of Open Access Journals (Sweden)

    Wust Peter

    2010-05-01

    Full Text Available Abstract Background To assess radiobiological restrictions and tolerance doses as well as other toxic effects derived from repeated applications of single-fraction high dose rate irradiation of small liver volumes in clinical practice. Methods Twenty patients with liver metastases were treated repeatedly (2 - 4 times at identical or intersecting locations by CT-guided interstitial brachytherapy with varying time intervals. Magnetic resonance imaging using the hepatocyte selective contrast media Gd-BOPTA was performed before and after treatment to determine the volume of hepatocyte function loss (called pseudolesion, and the last acquired MRI data set was merged with the dose distributions of all administered brachytherapies. We calculated the BED (biologically equivalent dose for a single dose d = 2 Gy for different α/β values (2, 3, 10, 20, 100 based on the linear-quadratic model and estimated the tolerance dose for liver parenchyma D90 as the BED exposing 90% of the pseudolesion in MRI. Results The tolerance doses D90 after repeated brachytherapy sessions were found between 22 - 24 Gy and proved only slightly dependent on α/β in the clinically relevant range of α/β = 2 - 10 Gy. Variance analysis showed a significant dependency of D90 with respect to the intervals between the first irradiation and the MRI control (p 90 and the pseudolesion's volume. No symptoms of liver dysfunction or other toxic effects such as abscess formation occurred during the follow-up time, neither acute nor on the long-term. Conclusions Inactivation of liver parenchyma occurs at a BED of approx. 22 - 24 Gy corresponding to a single dose of ~10 Gy (α/β ~ 5 Gy. This tolerance dose is consistent with the large potential to treat oligotopic and/or recurrent liver metastases by CT-guided HDR brachytherapy without radiation-induced liver disease (RILD. Repeated small volume irradiation may be applied safely within the limits of this study.

  12. Effects of a Single Bout of Resistance Exercise in Different Volumes on Endothelium Adaptations in Healthy Animals

    Directory of Open Access Journals (Sweden)

    Marcelo Mendonça Mota

    Full Text Available Abstract Background: Resistance exercise (RE has been recommended for patients with cardiovascular diseases. Recently, a few studies have demonstrated that the intensity of a single bout of RE has an effect on endothelial adaptations to exercise. However, there is no data about the effects of different volumes of RE on endothelium function. Objective: The aim of the study was to evaluate the effects of different volumes of RE in a single bout on endothelium-dependent vasodilatation and nitric oxide (NO synthesis in the mesenteric artery of healthy animals. Methods: Male Wistar rats were divided into three groups: Control (Ct; low-volume RE (LV, 5 sets x 10 repetitions and high-volume RE (HV, 15 sets x 10 repetitions. The established intensity was 70% of the maximal repetition test. After the exercise protocol, rings of mesenteric artery were used for assessment of vascular reactivity, and other mesenteric arteries were prepared for detection of measure NO production by DAF-FM fluorescence. Insulin responsiveness on NO synthesis was evaluated by stimulating the vascular rings with insulin (10 nM. Results: The maximal relaxation response to insulin increased in the HV group only as compared with the Ct group. Moreover, the inhibition of nitric oxide synthesis (L-NAME completely abolished the insulin-induced vasorelaxation in exercised rats. NO production showed a volume-dependent increase in the endothelial and smooth muscle layer. In endothelial layer, only Ct and LV groups showed a significant increase in NO synthesis when compared to their respective group under basal condition. On the other hand, in smooth muscle layer, NO fluorescence increased in all groups when compared to their respective group under basal condition. Conclusions: Our results suggest that a single bout of RE promotes vascular endothelium changes in a volume-dependent manner. The 15 sets x 10 repetitions exercise plan induced the greatest levels of NO synthesis.

  13. Effects of local single and fractionated X-ray doses on rat bone marrow blood flow and red blood cell volume

    International Nuclear Information System (INIS)

    Pitkaenen, M.A.; Hopewell, J.W.

    1985-01-01

    Time and dose dependent changes in blood flow and red blood cell volume were studied in the locally irradiated bone marrow of the rat femur after single and fractionated doses of X-rays. With the single dose of 10 Gy the bone marrow blood flow although initially reduced returned to the control levels by seven months after irradiation. With doses >=15 Gy the blood flow was still significantly reduced at seven months. The total dose levels predicted by the nominal standard dose equation for treatments in three, six or nine fractions produced approximately the same degree of reduction in the bone marrow blood flow seven months after the irradiation. However, the fall in the red blood cell volume was from 23 to 37% greater in the three fractions groups compared with that in the nine fractions groups. Using the red blood cell volume as a parameter the nominal standard dose formula underestimated the severity of radiation damage in rat bone marrow at seven months for irradiation with small numbers of large dose fractions. (orig.) [de

  14. Three-Dimensional Single-Port Labyrinthine Acoustic Metamaterial: Perfect Absorption with Large Bandwidth and Tunability

    Science.gov (United States)

    Zhang, Chi; Hu, Xinhua

    2016-12-01

    Metamaterials are engineered materials which exhibit fascinating properties unreachable by traditional materials. Here, we report on the design, fabrication, and experimental characterization of a three-dimensional single-port labyrinthine acoustic metamaterial. By using curled perforations with one end closed and with appropriate loss inside, the metamaterial can perfectly absorb airborne sounds in a low-frequency band. Both the position and the relative width of the band can be tuned flexibly. A trade-off is uncovered between the relative absorption bandwidth and thickness of the metamaterial. When the relative absorption bandwidth is as high as 51%, the requirement of deep-subwavelength thickness (0.07 λ ) can still be satisfied. We emphasize that the perfect absorption with large tunability in relative bandwidth (from 9% to >180 % ) was not attainable previously and may find applications ranging from noise reduction to sound imaging.

  15. Large Deflections Mechanical Analysis of a Suspended Single-Wall Carbon Nanotube under Thermoelectrical Loading

    Directory of Open Access Journals (Sweden)

    Assaf Ya'akobovitz

    2011-01-01

    Full Text Available Following the recent progress in integrating single-wall carbon nanotubes (SWCNTs into silicon-based micro-electromechanical systems (MEMS, new modeling tools are needed to predict their behavior under different loads, including thermal, electrical and mechanical. In the present study, the mechanical behavior of SWCNTs under thermoelectrical loading is analyzed using a large deflection geometrically nonlinear string model. The effect of the resistive heating was found to have a substantial influence on the SWCNTs behavior, including significant enhancement of the strain (up to the millistrains range and buckling due to the thermal expansion. The effect of local buckling sites was also studied and was found to enhance the local strain. The theoretical and numerical results obtained in the present study demonstrate the importance of resistive heating in the analysis of SWCNTs and provide an additional insight into the unique mechanics of suspended SWCNTs.

  16. Radioeffects on the advanced breast cancer treated preoperatively by a single large dose irradiation method

    International Nuclear Information System (INIS)

    Mikuriya, Shuichi; Konoeda, Koichi; Mikami, Akihiko

    1981-01-01

    A single irradiation with a large electron dose was applied on 26 cases of advanced breast cancer in National Medical Center Hospital. Pertinent voltage from 6 to 20 MeV betatron electron was selected in accordance with tumor sizes. In eight patients, 30 Gy were given at once and other patients were irradiated with fractionated dose from 10 to 20 Gy, two or three times within 2 or 3 weeks (total 28 - 38 Gy). The radioresponse in primary and metastatic lesions was macroscopically, histopathologically and immunologically examined. Direct effects of preoperative irradiation of the primary lesions in 18 out of 24 cases (75%) were relatively remarkable by histopathological examinations. Remarkable cellular infiltrations into tumor nests of primary lesions were observed in 14 out of 24 cases (58%). Abscopal effects on metastatic lymph nodes were observed macroscopically in 7 of 20 cases (35%) and microscopic abscopal effects were seen in 10 of 20 cases (50%). In 6 cases among these ten cases macroscopic abscopal effects were associated with microscopic ones. In tests for cellular immunity, blastoid formation rates of lymphocytes induced by PHA in vitro, lymphocytes and absolute numbers of T-cells in peripheral blood slightly decreased after the irradiation. However, in four kinds of skin tests, enhancements of the response were confirmed. The crude survival rate for 3 years of Stage III cases revealed 83.3% and relative survival rate of these cases was 85.5%. A single large electron dose for the treatment of advanced breast cancer may inhibit the depression of immunoreaction in hosts. (J.P.N.)

  17. Disease progression in patients with single, large-scale mitochondrial DNA deletions

    Science.gov (United States)

    Grady, John P.; Campbell, Georgia; Ratnaike, Thiloka; Blakely, Emma L.; Falkous, Gavin; Nesbitt, Victoria; Schaefer, Andrew M.; McNally, Richard J.; Gorman, Grainne S.; Taylor, Robert W.

    2014-01-01

    Single, large-scale deletions of mitochondrial DNA are a common cause of mitochondrial disease and cause a broad phenotypic spectrum ranging from mild myopathy to devastating multi-system syndromes such as Kearns-Sayre syndrome. Studies to date have been inconsistent on the value of putative predictors of clinical phenotype and disease progression such as mutation load and the size or location of the deletion. Using a cohort of 87 patients with single, large-scale mitochondrial DNA deletions we demonstrate that a variety of outcome measures such as COX-deficient fibre density, age-at-onset of symptoms and progression of disease burden, as measured by the Newcastle Mitochondrial Disease Adult Scale, are significantly (P < 0.05) correlated with the size of the deletion, the deletion heteroplasmy level in skeletal muscle, and the location of the deletion within the genome. We validate these findings with re-analysis of 256 cases from published data and clarify the previously conflicting information of the value of these predictors, identifying that multiple regression analysis is necessary to understand the effect of these interrelated predictors. Furthermore, we have used mixed modelling techniques to model the progression of disease according to these predictors, allowing a better understanding of the progression over time of this strikingly variable disease. In this way we have developed a new paradigm in clinical mitochondrial disease assessment and management that sidesteps the perennial difficulty of ascribing a discrete clinical phenotype to a broad multi-dimensional and progressive spectrum of disease, establishing a framework to allow better understanding of disease progression. PMID:24277717

  18. Scanning, Multibeam, Single Photon Lidars for Rapid, Large Scale, High Resolution, Topographic and Bathymetric Mapping

    Directory of Open Access Journals (Sweden)

    John J. Degnan

    2016-11-01

    Full Text Available Several scanning, single photon sensitive, 3D imaging lidars are herein described that operate at aircraft above ground levels (AGLs between 1 and 11 km, and speeds in excess of 200 knots. With 100 beamlets and laser fire rates up to 60 kHz, we, at the Sigma Space Corporation (Lanham, MD, USA, have interrogated up to 6 million ground pixels per second, all of which can record multiple returns from volumetric scatterers such as tree canopies. High range resolution has been achieved through the use of subnanosecond laser pulsewidths, detectors and timing receivers. The systems are presently being deployed on a variety of aircraft to demonstrate their utility in multiple applications including large scale surveying, bathymetry, forestry, etc. Efficient noise filters, suitable for near realtime imaging, have been shown to effectively eliminate the solar background during daytime operations. Geolocation elevation errors measured to date are at the subdecimeter level. Key differences between our Single Photon Lidars, and competing Geiger Mode lidars are also discussed.

  19. BEND-INDUCED LOSSES IN A SINGLE-MODE MICROSTRUCTURED FIBER WITH A LARGE CORE

    Directory of Open Access Journals (Sweden)

    Y. A. Gatchin

    2015-03-01

    Full Text Available A study of bend-induced losses in a silica-based single-mode microstructured fiber with a core diameter ranging from 20 to 35 microns and increased relative air content in the holey cladding has been conducted. With the use of the equivalent step-index profile method in approximation of waveguide parameters of microstructured fiber (normalized frequency and normalized transverse attenuation constant the effect of bending on the spectral position of the fundamentalmode short-wavelength leakage boundary has been analyzed. Upon measurement of spectral characteristics of attenuation in the considered fibers good accordance of numerical and experimental data has been found out. It is shown that increase of the air content in the holey cladding leads to expansion of the mentioned boundary to lower wavelengths for the value from 150 to 800 nm depending on the core size and bending conditions. A single-transverse-mode propagation is achieved on fiber length of 5-10 meters due to a substantial difference in losses of fundamental and higher-order guided modes attained by bending. Optical losses in all studied samples are less than 10 dB/km at the wavelength λ = 1550 nm. The results of the study can be applied in the design of high-power laser systems having such basic requirements as a relatively large mode spot and high beam quality.

  20. Fabrics, Facies And Flow Through A Large-Volume Ignimbrite: Pampa De Oxaya, Chile.

    Science.gov (United States)

    Platzman, Ellen; Cooper, Frances

    2016-04-01

    Large volume pyroclastic currents form during some of the most destructive volcanic eruptions on the planet, yet because they are underrepresented in the geological record they remain poorly understood. The Miocene Oxaya ignimbrites, exposed along the western Andean slopes in northern Chile, form one of the largest ignimbrite provinces on earth. We use anisotropy of magnetic susceptibility (AMS) in conjunction with rock magnetic measurements to investigate flow behavior and depositional processes in one of the largest members of the Oxaya succession, the Cardones ignimbrite. Despite its prominence the location of the source caldera remains unknown and fundamental processes remain poorly constrained. During 2012 nearly 8km (7,773m) of core was recovered from the early Miocene ignimbrites in 11 holes at elevations ranging from 2336m to 3805m along the Andean escarpment east of Arica, Chile. The drill cores are remarkable in that they penetrate through the entirety of the ignimbrite sequence and into the basement below. Samples for this study were collected from a > 1 km long core drilled at an altitude 3692m. The core sampled 981 m of Cardones ignimbrite and 15 m of underlying sediments and volcaniclastics before penetrating 148 m of basement. Detailed measurements of the variation in bulk magnetic properties including natural remanent magnetization (NRM), susceptibility, ARM, and IRM, were used to monitor changes in concentration, composition and grainsize of the magnetic components though the ignimbrite. AMS in conjunction with detailed rock magnetic measurements were used to constrain flow processes. The data reveal a well-defined flow direction and systematic variations in flow processes with depth. Low field bulk magnetic susceptibility averages 3.2x10-3 SI. Rock magnetic studies and petrographic examination indicate that magnetite is likely to be the dominant magnetic phase although paramagnetic mineral phases also contribute to the magnetic fabric. The degree

  1. Chromatographic lipophilicity determination using large volume injections of the solvents non-miscible with the mobile phase.

    Science.gov (United States)

    Sârbu, Costel; Naşcu-Briciu, Rodica Domnica; Casoni, Dorina; Kot-Wasik, Agata; Wasik, Andrzej; Namieśnik, Jacek

    2012-11-30

    A new perspective in the lipophilicity evaluation through RP-HPLC is permitted by analysis of the retention factor (k) obtained by injecting large volumes of test samples prepared in solvents immiscible with mobile phase. The experiment is carried out on representative groups of compounds with increased toxicity (mycotoxins and alkaloids) and amines with important biological activity (naturally occurring monoamine compounds and related drugs), which are covering a large interval of lipophilicity. The stock solution of each compound was prepared in hexane and the used mobile phases were mixtures of methanol or acetonitrile and water, in suited volume ratio. The injected volume was between 10 and 100 μL, while the used stationary phases were RP-18 and RP-8. On both reverse stationary phases the retention factors were linearly decreasing while the injection volume was increasing. In all cases, the linear models were highly statistically significant. On the basis of the obtained results new lipophilicity indices were purposed and discussed. The developed lipophilicity indices and the computationally expressed ones are correlated at a high level of statistical significance. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. Online automated in vivo zebrafish phosphoproteomics: from large-scale analysis down to a single embryo.

    Science.gov (United States)

    Lemeer, Simone; Pinkse, Martijn W H; Mohammed, Shabaz; van Breukelen, Bas; den Hertog, Jeroen; Slijper, Monique; Heck, Albert J R

    2008-04-01

    In the developing embryo, as in many other biological processes, complex signaling pathways are under tight control of reversible phosphorylation, guiding cell proliferation, differentiation, and growth. Therefore the large-scale identification of signaling proteins and their post-translational modifications is crucial to understand the proteome biology of the developing zebrafish embryo. Here, we used an automated, robust, and sensitive online TiO 2-based LC-MS/MS setup to enrich for phosphorylated peptides from 1 day old zebrafish embryos. We identified, with high confidence, 1067 endogenous phosphorylation sites in a sample taken from 60 embryos (approximately 180 microg), 321 from 10 embryos, and 47 phosphorylation sites from a single embryo, illustrating the sensitivity of the method. This data set, representing by far the largest for zebrafish, was further exploited by searching for serine/threonine or tyrosine kinase motifs using Scansite. For one-third of the identified phosphopeptides a potential kinase motif could be predicted, where it appeared that Cdk5 kinase, p38MAPK, PKA, and Casein Kinase 2 substrates were the most predominant motifs present, underpinning the importance of these kinases in signaling pathways in embryonic development. The phosphopeptide data set was further interrogated using alignments with phosphopeptides identified in recent large-scale phosphoproteomics screens in human and mouse samples. These alignments revealed conservation of phosphorylation sites in several proteins suggesting preserved function in embryonic development.

  3. Imaging characteristics of supratentorial ependymomas: Study on a large single institutional cohort with histopathological correlation.

    Science.gov (United States)

    Mangalore, Sandhya; Aryan, Saritha; Prasad, Chandrajit; Santosh, Vani

    2015-01-01

    Supratentorial ependymoma (STE) is a tumor whose unique clinical and imaging characteristics have not been studied. Histopathologically, they resemble ependymoma elsewhere. We retrospectively reviewed the imaging findings with clinicopathological correlation in a large number of patients with STE to identify these characteristics. Computed tomography (CT) magnetic resonance images (MRI), pathology reports, and clinical information from 41 patients with pathology-confirmed STE from a single institution were retrospectively reviewed. CT and MRI findings including location, size, signal intensity, hemorrhage, and enhancement pattern were tabulated and described separately in intraventricular and intraparenchymal forms. STE was more common in pediatric age group and intraparenchymal was more common than intraventricular form. The most common presentation was features of raised intracranial tension. There were equal numbers of Grade II and Grade III tumors. The imaging characteristics in adult and pediatric age group were similar. The tumor was large and had both solid and cystic components. Advanced imaging such as diffusion, perfusion, and spectroscopy were suggestive of high-grade tumor. Only differentiating factor between Grade II and Grade III was the presence of calcification. 1234 rule and periwinkle sign which we have described in this article may help characterize this tumor on imaging. This series expands the clinical and imaging spectrum of STE and identifies characteristics that should suggest consideration of this uncommon diagnosis.

  4. Space Situational Awareness of Large Numbers of Payloads From a Single Deployment

    Science.gov (United States)

    Segerman, A.; Byers, J.; Emmert, J.; Nicholas, A.

    2014-09-01

    The nearly simultaneous deployment of a large number of payloads from a single vehicle presents a new challenge for space object catalog maintenance and space situational awareness (SSA). Following two cubesat deployments last November, it took five weeks to catalog the resulting 64 orbits. The upcoming Kicksat mission will present an even greater SSA challenge, with its deployment of 128 chip-sized picosats. Although all of these deployments are in short-lived orbits, future deployments will inevitably occur at higher altitudes, with a longer term threat of collision with active spacecraft. With such deployments, individual scientific payload operators require rapid precise knowledge of their satellites' locations. Following the first November launch, the cataloguing did not initially associate a payload with each orbit, leaving this to the satellite operators. For short duration missions, the time required to identify an experiment's specific orbit may easily be a large fraction of the spacecraft's lifetime. For a Kicksat-type deployment, present tracking cannot collect enough observations to catalog each small object. The current approach is to treat the chip cloud as a single catalog object. However, the cloud dissipates into multiple subclouds and, ultimately, tiny groups of untrackable chips. One response to this challenge may be to mandate installation of a transponder on each spacecraft. Directional transponder transmission detections could be used as angle observations for orbit cataloguing. Of course, such an approach would only be employable with cooperative spacecraft. In other cases, a probabilistic association approach may be useful, with the goal being to establish the probability of an element being at a given point in space. This would permit more reliable assessment of the probability of collision of active spacecraft with any cloud element. This paper surveys the cataloguing challenges presented by large scale deployments of small spacecraft

  5. Effect of Bra Use during Radiotherapy for Large-Breasted Women: Acute Toxicity and Treated Heart and Lung Volumes.

    Science.gov (United States)

    Keller, Lanea; Cohen, Randi; Sopka, Dennis M; Li, Tianyu; Li, Linna; Anderson, Penny R; Fowble, Barbara L; Freedman, Gary M

    2013-01-01

    Large breast size presents special problems during radiation simulation, planning and patient treatment, including increased skin toxicity, in women undergoing breast-conserving surgery and radiotherapy (BCT). We report our experience using a bra during radiation in large-breasted women and its effect on acute toxicity and heart and lung dosimetry. From 2001 to 2006, 246 consecutive large-breasted women (bra size ≥ 38 and/or ≥ D cup) were treated with BCT using either 3D conformal (3D-CRT) or Intensity Modulated Radiation (IMRT). In 58 cases, at the physicians' discretion, a custom-fit bra was used during simulation and treatment. Endpoints were acute radiation dermatitis, and dosimetric comparison of heart and lung volumes in a subgroup of 12 left-sided breast cancer patients planned with and without a bra. The majority of acute skin toxicities were grade 2 and were experienced by 90% of patients in a bra compared to 70% of patients not in a bra (p=0.003). On multivariate analysis significant predictors of grade 2/3 skin toxicity included 3D-CRT instead of IMRT (OR=3.9, 95% CI:1.8-8.5) and the use of a bra (OR=5.5, 95% CI:1.6-18.8). For left-sided patients, use of a bra was associated with a volume of heart in the treatment fields decreased by 63.4% (p=0.002), a volume of left lung decreased by 18.5% (p=0.25), and chest wall separation decreased by a mean of 1 cm (p=0.03). The use of a bra to augment breast shape and position in large-breasted women is an alternative to prone positioning and associated with reduced chest wall separation and reduced heart volume within the treatment field.

  6. Effect of bra use during radiation therapy for large-breasted women: Acute toxicity and treated heart and lung volumes.

    Science.gov (United States)

    Keller, Lanea M M; Cohen, Randi; Sopka, Dennis M; Li, Tianyu; Li, Linna; Anderson, Penny R; Fowble, Barbara L; Freedman, Gary M

    2013-01-01

    Large breast size presents special problems during radiation simulation, planning, and patient treatment, including increased skin toxicity, in women undergoing breast-conserving surgery and radiation therapy (BCT). We report our experience using a bra during radiation in large-breasted women and its effect on acute toxicity and heart and lung dosimetry. From 2001 to 2006, 246 consecutive large-breasted women (bra size ≥38 or ≥D cup) were treated with BCT using either 3-dimensional conformal radiation therapy (3DCRT) or intensity modulated radiation therapy (IMRT). In 58 cases, at the physicians' discretion, a custom-fit bra was used during simulation and treatment. Endpoints were acute radiation dermatitis and dosimetric comparison of heart and lung volumes in a subgroup of 12 left-sided breast cancer patients planned with and without a bra. The majority of acute skin toxicities were grade 2 and were experienced by 90% of patients in a bra compared with 70% of patients not in a bra (P = .003). On multivariate analysis significant predictors of grade 2 or 3 skin toxicity included the use of 3DCRT instead of IMRT (odds ratio, 3.9; 95% confidence interval, 1.8-8.5) and the use of a bra (odds ratio, 5.5; 95% confidence interval, 1.6-18.8). For left-sided patients, the use of a bra was associated with a volume of heart in the treatment fields decreased by 63.4% (P = .002), a volume of left lung decreased by 18.5% (P = .25), and chest wall separation decreased by a mean of 1 cm (P = .03). The use of a bra to augment breast shape and position in large-breasted women is an alternative to prone positioning and associated with reduced chest wall separation and reduced heart volume within the treatment field. Copyright © 2013 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  7. A Monte-Carlo code for neutron efficiency calculations for large volume Gd-loaded liquid scintillation detectors

    Energy Technology Data Exchange (ETDEWEB)

    Trzcinski, A.; Zwieglinski, B. [Soltan Inst. for Nuclear Studies, Warsaw (Poland); Lynen, U. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (Germany); Pochodzalla, J. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    1998-10-01

    This paper reports on a Monte-Carlo program, MSX, developed to evaluate the performance of large-volume, Gd-loaded liquid scintillation detectors used in neutron multiplicity measurements. The results of simulations are presented for the detector intended to count neutrons emitted by the excited target residue in coincidence with the charged products of the projectile fragmentation following relativistic heavy-ion collisions. The latter products could be detected with the ALADIN magnetic spectrometer at GSI-Darmstadt. (orig.) 61 refs.

  8. Design and Analysis of A Beacon-Less Routing Protocol for Large Volume Content Dissemination in Vehicular Ad Hoc Networks.

    Science.gov (United States)

    Hu, Miao; Zhong, Zhangdui; Ni, Minming; Baiocchi, Andrea

    2016-11-01

    Large volume content dissemination is pursued by the growing number of high quality applications for Vehicular Ad hoc NETworks(VANETs), e.g., the live road surveillance service and the video-based overtaking assistant service. For the highly dynamical vehicular network topology, beacon-less routing protocols have been proven to be efficient in achieving a balance between the system performance and the control overhead. However, to the authors' best knowledge, the routing design for large volume content has not been well considered in the previous work, which will introduce new challenges, e.g., the enhanced connectivity requirement for a radio link. In this paper, a link Lifetime-aware Beacon-less Routing Protocol (LBRP) is designed for large volume content delivery in VANETs. Each vehicle makes the forwarding decision based on the message header information and its current state, including the speed and position information. A semi-Markov process analytical model is proposed to evaluate the expected delay in constructing one routing path for LBRP. Simulations show that the proposed LBRP scheme outperforms the traditional dissemination protocols in providing a low end-to-end delay. The analytical model is shown to exhibit a good match on the delay estimation with Monte Carlo simulations, as well.

  9. High Power Compact Single-Frequency Volume Bragg Er-Doped Fiber Laser, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal is based on successful results of Phase I project where it was shown that the use of volume Bragg gratings in PTR glass as selectors of transverse and...

  10. Genetic influences on schizophrenia and subcortical brain volumes: large-scale proof of concept

    OpenAIRE

    Franke, B.; Stein, J. L.; Ripke, S.; Anttila, V.; Hibar, D. P.; van Hulzen, K. J.; Arias-Vasquez, A.; Smoller, J. W.; Nichols, T. E.; Neale, M. C.; McIntosh, A. M.; Lee, P.; McMahon, F. J.; Meyer-Lindenberg, A.; Mattheisen, M.

    2016-01-01

    Schizophrenia is a devastating psychiatric illness with high heritability. Brain structure and function differ, on average, between people with schizophrenia and healthy individuals. As common genetic associations are emerging for both schizophrenia and brain imaging phenotypes, we can now use genome-wide data to investigate genetic overlap. Here we integrated results from common variant studies of schizophrenia (33,636 cases, 43,008 controls) and volumes of several (mainly subcortical) brain...

  11. Large scale prop-fan structural design study. Volume 1: Initial concepts

    Science.gov (United States)

    Billman, L. C.; Gruska, C. J.; Ladden, R. M.; Leishman, D. K.; Turnberg, J. E.

    1988-01-01

    In recent years, considerable attention has been directed toward improving aircraft fuel consumption. Studies have shown that the inherent efficiency advantage that turboprop propulsion systems have demonstrated at lower cruise speeds may now be extended to the higher speeds of today's turbofan and turbojet-powered aircraft. To achieve this goal, new propeller designs will require features such as thin, high speed airfoils and aerodynamic sweep, features currently found only in wing designs for high speed aircraft. This is Volume 1 of a 2 volume study to establish structural concepts for such advanced propeller blades, to define their structural properties, to identify any new design, analysis, or fabrication techniques which were required, and to determine the structural tradeoffs involved with several blade shapes selected primarily on the basis of aero/acoustic design considerations. The feasibility of fabricating and testing dynamically scaled models of these blades for aeroelastic testing was also established. The preliminary design of a blade suitable for flight use in a testbed advanced turboprop was conducted and is described in Volume 2.

  12. Genetic influences on schizophrenia and subcortical brain volumes: large-scale proof-of-concept and roadmap for future studies

    Science.gov (United States)

    Anttila, Verneri; Hibar, Derrek P; van Hulzen, Kimm J E; Arias-Vasquez, Alejandro; Smoller, Jordan W; Nichols, Thomas E; Neale, Michael C; McIntosh, Andrew M; Lee, Phil; McMahon, Francis J; Meyer-Lindenberg, Andreas; Mattheisen, Manuel; Andreassen, Ole A; Gruber, Oliver; Sachdev, Perminder S; Roiz-Santiañez, Roberto; Saykin, Andrew J; Ehrlich, Stefan; Mather, Karen A; Turner, Jessica A; Schwarz, Emanuel; Thalamuthu, Anbupalam; Shugart, Yin Yao; Ho, Yvonne YW; Martin, Nicholas G; Wright, Margaret J

    2016-01-01

    Schizophrenia is a devastating psychiatric illness with high heritability. Brain structure and function differ, on average, between schizophrenia cases and healthy individuals. As common genetic associations are emerging for both schizophrenia and brain imaging phenotypes, we can now use genome-wide data to investigate genetic overlap. Here we integrated results from common variant studies of schizophrenia (33,636 cases, 43,008 controls) and volumes of several (mainly subcortical) brain structures (11,840 subjects). We did not find evidence of genetic overlap between schizophrenia risk and subcortical volume measures either at the level of common variant genetic architecture or for single genetic markers. The current study provides proof-of-concept (albeit based on a limited set of structural brain measures), and defines a roadmap for future studies investigating the genetic covariance between structural/functional brain phenotypes and risk for psychiatric disorders. PMID:26854805

  13. PFAPA syndrome: clinical characteristics and treatment outcomes in a large single-centre cohort.

    Science.gov (United States)

    Król, Petra; Böhm, Marek; Sula, Viktor; Dytrych, Petra; Katra, Rami; Nemcová, Dana; Dolezalová, Pavla

    2013-01-01

    This paper aims to describe clinical and laboratory features and disease outcome in a single-centre cohort of patients with PFAPA syndrome (Periodic Fever, Aphtous stomatitis, Pharyngitis, and Adenitis) and to test performance of diagnostic and therapeutic algorithms. Patients fulfilling criteria were selected from the fever clinic population. Prospective follow-up together with recruitment of newly diagnosed patients followed pre-defined guidelines. Diagnostic and therapeutic algorithms and definitions of outcome and therapy response were formulated. Paired blood samples during febrile and afebrile periods were compared. Out of 176 patients referred for suspected periodic fever 125 children fulfilled criteria. Their age at onset was 23 months, median episode duration 3.5 days at 4-week intervals. Fever was associated with pharyngitis (91%), cervical adenitis (78%) and aphtae (41%). Among therapeutic options, episodic prednisone proved to be the most common first-line treatment. Administered to 77 patients, it reduced symptoms in 94%. Tonsillectomy led to the full symptom resolution in all 18 patients. Forty-six patients reached disease remission. Distribution of typical symptoms, response to therapies and disease outcome in a large patient cohort were documented. We offer diagnostic and therapeutic algorithms that have proven effective during this prospective trial. Our findings support the general belief of benign nature of this aetiologically unclear condition, despite proportion of patients having persistent disease for years. Maintenance of normal findings in afebrile intervals, striking response to a single dose of prednisone and normal growth and development together with spontaneous tendency towards prolongation of afebrile intervals are important confirmatory features of PFAPA syndrome.

  14. High-Accuracy Elevation Data at Large Scales from Airborne Single-Pass SAR Interferometry

    Directory of Open Access Journals (Sweden)

    Guy Jean-Pierre Schumann

    2016-01-01

    Full Text Available Digital elevation models (DEMs are essential data sets for disaster risk management and humanitarian relief services as well as many environmental process models. At present, on the hand, globally available DEMs only meet the basic requirements and for many services and modeling studies are not of high enough spatial resolution and lack accuracy in the vertical. On the other hand, LiDAR-DEMs are of very high spatial resolution and great vertical accuracy but acquisition operations can be very costly for spatial scales larger than a couple of hundred square km and also have severe limitations in wetland areas and under cloudy and rainy conditions. The ideal situation would thus be to have a DEM technology that allows larger spatial coverage than LiDAR but without compromising resolution and vertical accuracy and still performing under some adverse weather conditions and at a reasonable cost. In this paper, we present a novel single pass In-SAR technology for airborne vehicles that is cost-effective and can generate DEMs with a vertical error of around 0.3 m for an average spatial resolution of 3 m. To demonstrate this capability, we compare a sample single-pass In-SAR Ka-band DEM of the California Central Valley from the NASA/JPL airborne GLISTIN-A to a high-resolution LiDAR DEM. We also perform a simple sensitivity analysis to floodplain inundation. Based on the findings of our analysis, we argue that this type of technology can and should be used to replace large regions of globally available lower resolution DEMs, particularly in coastal, delta and floodplain areas where a high number of assets, habitats and lives are at risk from natural disasters. We conclude with a discussion on requirements, advantages and caveats in terms of instrument and data processing.

  15. Paul Scherrer Institute Scientific Report 1998. Volume VI: Large Research Facilities

    International Nuclear Information System (INIS)

    Bauer, Guenter; Bercher, Renate; Buechli, Carmen; Foroughi, Fereydoun; Meyer, Rosa

    1999-01-01

    The department GFA (Grossforschungsanlagen, Large Research Facilities) has been established in October 1998 and its main duty is operation, maintenance and development of the PSI accelerators, the spallation neutron source and the beam transport systems for pions and muons. A large effort of this group concerns the planning and co-ordination of the assembly of the Swiss Light Source (SLS). (author)

  16. An evaluation of a new single-use flexible bronchoscope with a large suction channel: reliability of bronchoalveolar lavage in ventilated piglets and initial clinical experience.

    Science.gov (United States)

    Mankikian, J; Ehrmann, S; Guilleminault, L; Le Fol, T; Barc, C; Ferrandière, M; Boulain, T; Dequin, P F; Guillon, A

    2014-07-01

    A single-use flexible bronchoscope with a large suction channel has become available recently and we have evaluated this innovative device. Firstly, bronchoalveolar lavage was performed and quantified in ventilated piglets. Next, the bronchoscope was evaluated in three intensive care units and a satisfaction questionnaire was carried out. Sixteen bronchoalveolar lavages were performed in piglets with a recovery rate of 83 (79-86 [72-89])% of the instilled volume. Quality and performance of all devices tested was identical. The medical satisfaction questionnaire was as follows: 'acceptable' to 'very good' for quality of aspiration, manoeuvrability and quality of vision; 'very good' to 'perfect' for setting up and insertion. This encouraging preliminary evaluation demonstrates the effectiveness of this new single-use device, which may obviate the need for disinfection procedures and, thereby, eradicate a potential vector of patient cross-contamination. © 2014 The Association of Anaesthetists of Great Britain and Ireland.

  17. Genetics of single-cell protein abundance variation in large yeast populations

    Science.gov (United States)

    Albert, Frank W.; Treusch, Sebastian; Shockley, Arthur H.; Bloom, Joshua S.; Kruglyak, Leonid

    2014-02-01

    Variation among individuals arises in part from differences in DNA sequences, but the genetic basis for variation in most traits, including common diseases, remains only partly understood. Many DNA variants influence phenotypes by altering the expression level of one or several genes. The effects of such variants can be detected as expression quantitative trait loci (eQTL). Traditional eQTL mapping requires large-scale genotype and gene expression data for each individual in the study sample, which limits sample sizes to hundreds of individuals in both humans and model organisms and reduces statistical power. Consequently, many eQTL are probably missed, especially those with smaller effects. Furthermore, most studies use messenger RNA rather than protein abundance as the measure of gene expression. Studies that have used mass-spectrometry proteomics reported unexpected differences between eQTL and protein QTL (pQTL) for the same genes, but these studies have been even more limited in scope. Here we introduce a powerful method for identifying genetic loci that influence protein expression in the yeast Saccharomyces cerevisiae. We measure single-cell protein abundance through the use of green fluorescent protein tags in very large populations of genetically variable cells, and use pooled sequencing to compare allele frequencies across the genome in thousands of individuals with high versus low protein abundance. We applied this method to 160 genes and detected many more loci per gene than previous studies. We also observed closer correspondence between loci that influence protein abundance and loci that influence mRNA abundance of a given gene. Most loci that we detected were clustered in `hotspots' that influence multiple proteins, and some hotspots were found to influence more than half of the proteins that we examined. The variants that underlie these hotspots have profound effects on the gene regulatory network and provide insights into genetic variation in cell

  18. Large-Scale Context-Aware Volume Navigation using Dynamic Insets

    KAUST Repository

    Al-Awami, Ali

    2012-07-01

    Latest developments in electron microscopy (EM) technology produce high resolution images that enable neuro-scientists to identify and put together the complex neural connections in a nervous system. However, because of the massive size and underlying complexity of this kind of data, processing, navigation and analysis suffer drastically in terms of time and effort. In this work, we propose the use of state-of- the-art navigation techniques, such as dynamic insets, built on a peta-scale volume visualization framework to provide focus and context-awareness to help neuro-scientists in their mission to analyze, reconstruct, navigate and explore EM neuroscience data.

  19. Paul Scherrer Institute Scientific and Technical Report 1999. Volume VI: Large Research Facilities

    International Nuclear Information System (INIS)

    Foroughi, Fereydoun; Bercher, Renate; Buechli, Carmen; Meyer, Rosa

    2000-01-01

    The department GFA (Grossforschungsanlagen, Large Research Facilities) has been established in October 1998. Its main duty is operation, maintenance and development of the PSI accelerators, the spallation neutron source and the beam transport systems for pions and muons. A large effort of this group concerns the planning and co-ordination of new projects like e.g. the assembly of the synchrotron light source (SLS), design studies of a new proton therapy facility, the ultracold neutron source and a new intensive secondary beam line for low energy muons. A large fraction of this report is devoted to research especially in the field of materials Science. The studies include large scale molecular dynamics computer simulations on the elastic and plastic behavior of nanostructured metals, complemented by experimental mechanical testing using micro-indentation and miniaturized tensile testing, as well as microstructural characterisation and strain field mapping of metallic coatings and thin ceramic layers, the latter done with synchrotron radiation

  20. Paul Scherrer Institute Scientific and Technical Report 1999. Volume VI: Large Research Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Foroughi, Fereydoun; Bercher, Renate; Buechli, Carmen; Meyer, Rosa [eds.

    2000-07-01

    The department GFA (Grossforschungsanlagen, Large Research Facilities) has been established in October 1998. Its main duty is operation, maintenance and development of the PSI accelerators, the spallation neutron source and the beam transport systems for pions and muons. A large effort of this group concerns the planning and co-ordination of new projects like e.g. the assembly of the synchrotron light source (SLS), design studies of a new proton therapy facility, the ultracold neutron source and a new intensive secondary beam line for low energy muons. A large fraction of this report is devoted to research especially in the field of materials Science. The studies include large scale molecular dynamics computer simulations on the elastic and plastic behavior of nanostructured metals, complemented by experimental mechanical testing using micro-indentation and miniaturized tensile testing, as well as microstructural characterisation and strain field mapping of metallic coatings and thin ceramic layers, the latter done with synchrotron radiation.

  1. New 50-M-Class Single Dish Telescope: Large Submillimeter Telescope (LST)

    Science.gov (United States)

    Kawabe, Ryohei

    2018-01-01

    We report on the plan to construct a 50 m class millimeter (mm) and sub-mm single dish telescope, the Large Submillimeter Telescope (LST). The telescope is optimized for wide-area imaging and spectroscopic surveys in the 70 to 420 GHz main frequency range, which just covers main atmospheric windows at millimeter and submillimeter wavelengths for good observing sites such as the ALMA site in Chile. We also target observations at higher frequencies of up to 1 THz, using an inner part high-precision surface. Active surface control is required in order to correct gravitational and thermal deformations of the surface. The LST will facilitate new discovery spaces such as wide-field imaging with both continuum and spectral lines, along with new developments for time domain science. With exploiting synergy with ALMA and other telescopes, LST can contribute to a wide range of topics in astronomy and astrophysics, e.g., astrochemistry, star formation in the Galaxy and galaxies, evolution of galaxy clusters via SZ effect. We also report the recent progress on the technical study, e.g., the tentative study of the surface error budget and challenges to correction for the wind-load effect.

  2. Large-Area High Aspect Ratio Plasmonic Interference Lithography Utilizing a Single High-k Mode.

    Science.gov (United States)

    Chen, Xi; Yang, Fan; Zhang, Cheng; Zhou, Jing; Guo, L Jay

    2016-04-26

    Plasmonic lithography, which utilizes subwavelength confinement of surface plasmon polartion (SPP) waves, has the capability of breaking the diffraction limit and delivering high resolution. However, all previously reported results suffer from critical issues, such as shallow pattern depth and pattern nonuniformity even over small exposure areas, which limit the application of the technology. In this work, periodic patterns with high aspect ratios and a half-pitch of about 1/6 of the wavelength were achieved with pattern uniformity in square centimeter areas. This was accomplished by designing a special mask and photoresist (PR) system to select a single high spatial frequency mode and incorporating the PR into a waveguide configuration to ensure uniform light exposure over the entire depth of the photoresist layer. In addition to the experimental progress toward large-scale applications of plasmonic interference lithography, the general criteria of designing such an exposure system is also discussed, which can be used for nanoscale fabrication in this fashion for various applications with different requirements for wavelength, pitch, aspect ratio, and structure.

  3. Oxygen-activated growth and bandgap tunability of large single-crystal bilayer graphene

    Energy Technology Data Exchange (ETDEWEB)

    Hao, Yufeng; Wang, Lei; Liu, Yuanyue; Chen, Hua; Wang, Xiaohan; Tan, Cheng; Nie, Shu; Suk, Ji Won; Jiang, Tengfei; Liang, Tengfei; Xiao, Junfeng; Ye, Wenjing; Dean, Cory R.; Yakobson, Boris I.; McCarty, Kevin F.; Kim, Philip; Hone, James; Colombo, Luigi; Ruoff, Rodney S.

    2016-02-01

    Bernal (AB)-stacked bilayer graphene (BLG) is a semiconductor whose bandgap can be tuned by a transverse electric field, making it a unique material for a number of electronic and photonic devices. A scalable approach to synthesize high-quality BLG is therefore critical, which requires minimal crystalline defects in both graphene layers and maximal area of Bernal stacking, which is necessary for bandgap tunability. Here we demonstrate that in an oxygen-activated chemical vapour deposition (CVD) process, half-millimetre size, Bernal-stacked BLG single crystals can be synthesized on Cu. Besides the traditional 'surface-limited' growth mechanism for SLG (1st layer), we discovered new microscopic steps governing the growth of the 2nd graphene layer below the 1st layer as the diffusion of carbon atoms through the Cu bulk after complete dehydrogenation of hydrocarbon molecules on the Cu surface, which does not occur in the absence of oxygen. Moreover, we found that the efficient diffusion of the carbon atoms present at the interface between Cu and the 1st graphene layer further facilitates growth of large domains of the 2nd layer. The CVD BLG has superior electrical quality, with a device on/off ratio greater than 104, and a tunable bandgap up to -100 meV at a displacement field of 0.9 V nm-1.

  4. Use of single large or several small policies as strategies to manage people-park interactions.

    Science.gov (United States)

    Mackenzie, Catrina A; Baird, Timothy D; Hartter, Joel

    2014-12-01

    Biodiversity conservation has been criticized for undermining or ignoring social well-being. Currently efforts to mutually promote social justice, rural development, and biodiversity conservation, which have been contentious and yielded mixed results, continue to spread despite a general dearth of effective management strategies. We contend that social and economic concerns should be integral to conservation planning and propose that the scale of these phenomena is also critical. To evaluate the merit of this proposal, we adopted and expanded a conservation management strategy framework developed by Joel Heinen and examined how population density, economic disparity, and ethnic heterogeneity vary spatially surrounding 2 contrasting protected areas in East Africa: Kibale National Park in Uganda and Tarangire National Park in Tanzania. Analyses of demographic, wealth, and ethnicity data from regional censuses and household surveys conducted in 2009 and 2010 indicated that choice of scale (landscape or community) changed the management strategies recommended by the model. Therefore, "several small" people-park management strategies varying around a given protected area may be more appropriate than a "single large" people-park strategy applied across an entire protected area. Correspondingly, scale adjusted Heinen recommendations offered new strategies for effective conservation management within these human landscapes not incorporated in current in situ management plans. © 2014 Society for Conservation Biology.

  5. Single Locus Maintains Large Variation of Sex Reversal in Half-Smooth Tongue Sole (Cynoglossus semilaevis).

    Science.gov (United States)

    Jiang, Li; Li, Hengde

    2017-02-09

    Sex determination is a fundamental biological process for individual sex development and population sex ratios. However, for some species, the primary sex might be altered during development, and individuals can develop into the opposite sex. Sex reversal may happen in insects, reptiles, amphibians, and fishes. In half-smooth tongue sole ( Cynoglossus semilaevis ), some genetically female fish irreversibly reverse to pseudomales, resulting in higher costs in aquaculture owing to a lower growth rate of male fish during a 2-yr growth period. Here, we identified a locus with large controlling effect on sex reversal in the half-smooth tongue sole through genome-wide association study with high-density single nucleotide polymorphisms (SNPs). This SNP is located at the third intron of the F-box and leucine rich repeat protein 17 ( FBXL17 ) gene on the Z chromosome, and it has two alleles, A and T. Genetic females with Z A W genotypes will never reverse into phenotypic males, but those with Z T W genotypes can sometimes undergo sex reversal. This SNP explains 82.7% of the genetic variation, or 58.4% of the phenotypic variation. Based on our results, a reproductive management program could be developed to improve the phenotypic female ratio in aquaculture, and elucidate the mechanism of sex reversal in half-smooth tongue sole. We expect that these findings will have a substantial impact on the population management in many harvested species where sex reversal occurs. Copyright © 2017 Jiang and Li.

  6. Single Locus Maintains Large Variation of Sex Reversal in Half-Smooth Tongue Sole (Cynoglossus semilaevis

    Directory of Open Access Journals (Sweden)

    Li Jiang

    2017-02-01

    Full Text Available Sex determination is a fundamental biological process for individual sex development and population sex ratios. However, for some species, the primary sex might be altered during development, and individuals can develop into the opposite sex. Sex reversal may happen in insects, reptiles, amphibians, and fishes. In half-smooth tongue sole (Cynoglossus semilaevis, some genetically female fish irreversibly reverse to pseudomales, resulting in higher costs in aquaculture owing to a lower growth rate of male fish during a 2-yr growth period. Here, we identified a locus with large controlling effect on sex reversal in the half-smooth tongue sole through genome-wide association study with high-density single nucleotide polymorphisms (SNPs. This SNP is located at the third intron of the F-box and leucine rich repeat protein 17 (FBXL17 gene on the Z chromosome, and it has two alleles, A and T. Genetic females with ZAW genotypes will never reverse into phenotypic males, but those with ZTW genotypes can sometimes undergo sex reversal. This SNP explains 82.7% of the genetic variation, or 58.4% of the phenotypic variation. Based on our results, a reproductive management program could be developed to improve the phenotypic female ratio in aquaculture, and elucidate the mechanism of sex reversal in half-smooth tongue sole. We expect that these findings will have a substantial impact on the population management in many harvested species where sex reversal occurs.

  7. Paul Scherrer Institute Scientific Report 1998. Volume VI: Large Research Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Guenter; Bercher, Renate; Buechli, Carmen; Foroughi, Fereydoun; Meyer, Rosa [eds.

    1999-09-01

    The department GFA (Grossforschungsanlagen, Large Research Facilities) has been established in October 1998 and its main duty is operation, maintenance and development of the PSI accelerators, the spallation neutron source and the beam transport systems for pions and muons. A large effort of this group concerns the planning and co-ordination of the assembly of the Swiss Light Source (SLS). (author) figs., tabs., refs.

  8. Non-equilibrium Inertial Separation Array for High-throughput, Large-volume Blood Fractionation.

    Science.gov (United States)

    Mutlu, Baris R; Smith, Kyle C; Edd, Jon F; Nadar, Priyanka; Dlamini, Mcolisi; Kapur, Ravi; Toner, Mehmet

    2017-08-30

    Microfluidic blood processing is used in a range of applications from cancer therapeutics to infectious disease diagnostics. As these applications are being translated to clinical use, processing larger volumes of blood in shorter timescales with high-reliability and robustness is becoming a pressing need. In this work, we report a scaled, label-free cell separation mechanism called non-equilibrium inertial separation array (NISA). The NISA mechanism consists of an array of islands that exert a passive inertial lift force on proximate cells, thus enabling gentler manipulation of the cells without the need of physical contact. As the cells follow their size-based, deterministic path to their equilibrium positions, a preset fraction of the flow is siphoned to separate the smaller cells from the main flow. The NISA device was used to fractionate 400 mL of whole blood in less than 3 hours, and produce an ultrapure buffy coat (96.6% white blood cell yield, 0.0059% red blood cell carryover) by processing whole blood at 3 mL/min, or ∼300 million cells/second. This device presents a feasible alternative for fractionating blood for transfusion, cellular therapy and blood-based diagnostics, and could significantly improve the sensitivity of rare cell isolation devices by increasing the processed whole blood volume.

  9. Large pyramid shaped single crystals of BiFeO{sub 3} by solvothermal synthesis method

    Energy Technology Data Exchange (ETDEWEB)

    Sornadurai, D.; Ravindran, T. R.; Paul, V. Thomas; Sastry, V. Sankara [Condensed Matter Physics Division, Materials Science Group, Physical Metallurgy Division, Metallurgy and Materials Group, Indira Gandhi Centre for Atomic Research, Kalpakkam, Tamil Nadu (India); Condensed Matter Physics Division, Materials Science Group (India)

    2012-06-05

    Synthesis parameters are optimized in order to grow single crystals of multiferroic BiFeO{sub 3}. 2 to 3 mm size pyramid (tetrahedron) shaped single crystals were successfully obtained by solvothermal method. Scanning electron microscopy with EDAX confirmed the phase formation. Raman scattering spectra of bulk BiFeO3 single crystals have been measured which match well with reported spectra.

  10. Critical Joints in Large Composite Primary Aircraft Structures. Volume 3: Ancillary Test Results

    Science.gov (United States)

    Bunin, Bruce L.; Sagui, R. L.

    1985-01-01

    A program was conducted to develop the technology for critical structural joints for composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of a comprehensive ancillary test program are summarized, consisting of single-bolt composite joint specimens tested in a variety of configurations. These tests were conducted to characterize the strength and load deflection properties that are required for multirow joint analysis. The composite material was Toray 300 fiber and Ciba-Geigy 914 resin, in the form of 0.005 and 0.01 inch thick unidirectional tape. Tests were conducted in single and double shear for loaded and unloaded hole configurations under both tensile and compressive loading. Two different layup patterns were examined. All tests were conducted at room temperature. In addition, the results of NASA Standard Toughness Test (NASA RP 1092) are reported, which were conducted for several material systems.

  11. Self-Similar Nanocavity Design with Ultrasmall Mode Volume for Single-Photon Nonlinearities

    DEFF Research Database (Denmark)

    Choi, Hyeongrak; Heuck, Mikkel; Englund, Dirk R.

    2017-01-01

    illustrate the design concept with a silicon-air one-dimensional photon crystal cavity that reaches an ultrasmall mode volume of V-eff similar to 7.01 x 10(-5)lambda(3) at lambda similar to 1550 nm. We show that the extreme light concentration in our design can enable ultrastrong Kerr nonlinearities, even...

  12. Reliability of estimating the room volume from a single room impulse response

    NARCIS (Netherlands)

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and

  13. Glass-covering of large building volumes. An interdisciplinary evaluation of a shopping centre

    Energy Technology Data Exchange (ETDEWEB)

    Oeman, R. [Royal Inst. of Tech., Stockholm (Sweden). Dept. of Building Technology

    1994-12-31

    Systematized experiences of the function of large glass-covered spaces related to shopping centres, hotels, office buildings etc. are still relatively limited. With the glazed pedestrian precincts of the rebuilt Skaerholmen Centre in Stockholm as the main object of interdisciplinary studies, the aim of this thesis is to provide additional knowledge of large glass-covered spaces (atrium buildings). The studies comprises thermal comfort, temperature conditions, ventilation, energy balance, humidity - mycology, acoustics, operation - maintenance - durability and sociology. To sum up, it is clear that in the Scandinavian climate there is every likelihood of large glass-covered spaces in the public places functioning well from a technical as well as a social point of view. The energy consumption on heating the whole complex, based on theoretical calculations and measurement, is shown to have been reduced by the order of 10%. figs., tabs., refs.

  14. Low temperature system for a large volume multi-anvil press

    Science.gov (United States)

    Secco, Richard A.; Yong, Wenjun

    2016-12-01

    A new custom-designed system for a 3000 ton multi-anvil press has been developed to reach temperatures below room temperature at high pressures. The system was designed to remove heat selectively and conductively from the sample volume through six of the eight tungsten carbide (WC) cubes in direct contact with the octahedral pressure cell. The key components of the system include Cu cooling fins sandwiched between neighboring cube faces and the connected Cu heat exchange chamber through which liquid nitrogen flows. Currently, this system enables us to reach temperatures down to 220 K at pressures up to 8 GPa, but it can be easily modified to retain similar cooling capability at the highest pressure the press can reach (ca. 25 GPa).

  15. Large-volume heat storage tank made of GFK; Grosswaermespeichertank aus GFK

    Energy Technology Data Exchange (ETDEWEB)

    Buehl, J.; Schultheis, P. [Technische Univ. Ilmenau (Germany). Fachgebiet Technische Thermodynamik

    1998-12-31

    The Technical University of Ilmenau, the company Verbundwerkstoff- und Kunststoffanwendungstechnik Schoenbrunn, the Institute for Aerospace and Light-weight construction of Dresden University with its approved testing facilities for plastics and the Institute for Construction Engineering in Berlin and several other institutions co-operated since 1996 in developing a concept for a series of long-term heat storage tanks up to 6,000 cubic metres storage volume made of plastic (GFK components) with a combined thermal insulation. A model tank (sandwich body with proportional thermal insulation layer and selected mixed laminates) with a volume of 1.5 cubic metres was built and installed in November 1996. The tank has been continuously operated at various test levels. The experiment proves the longevity of the materials used. (orig.) [Deutsch] In Zusammenarbeit der TU Ilmenau mit der Fa. Verbundwerkstoff - und Kunststoffanwendungstechnik Schoenbrunn und dem Institut fuer Luftfahrttechnik und Leichtbau Dresden, seiner akkredierten Pruefstelle fuer Kunststoffe, in Abstimmung mit dem Institut fuer Bautechnik Berlin und weiteren Einrichtungen und Partnern wird seit 1996 an einem Konzept fuer eine Typenreihe Langzeitwaermespeicher bis vorerst 6.000 m{sup 3} Speichervolumen aus Kunststoff (GFK-Komponenten) und kombinierter integrierter thermischer Isolation gearbeitet. Im Vorfeld dieser Entwicklung wurde auf der Basis vorausgewaehlter Materialien und Kompositionen ein Musterspeicher (ein Sandwich - Modellkoerper mit proportionaler Waermedaemmschicht sowie ausgewaehlten Mischlaminaten) mit einem Speichervolumen von 1,5 m{sup 3} realisiert. Dieser Musterspeicher wurde im November 1996 installiert und wird seither kontinuierlich in den entsprechenden Erprobungsstufen betrieben. Der Nachweis der Langlebigkeit der eingesetzten Materialien wurde experimentell erbracht. (orig.)

  16. The BREAST-V: a unifying predictive formula for volume assessment in small, medium, and large breasts.

    Science.gov (United States)

    Longo, Benedetto; Farcomeni, Alessio; Ferri, Germano; Campanale, Antonella; Sorotos, Micheal; Santanelli, Fabio

    2013-07-01

    Breast volume assessment enhances preoperative planning of both aesthetic and reconstructive procedures, helping the surgeon in the decision-making process of shaping the breast. Numerous methods of breast size determination are currently reported but are limited by methodologic flaws and variable estimations. The authors aimed to develop a unifying predictive formula for volume assessment in small to large breasts based on anthropomorphic values. Ten anthropomorphic breast measurements and direct volumes of 108 mastectomy specimens from 88 women were collected prospectively. The authors performed a multivariate regression to build the optimal model for development of the predictive formula. The final model was then internally validated. A previously published formula was used as a reference. Mean (±SD) breast weight was 527.9 ± 227.6 g (range, 150 to 1250 g). After model selection, sternal notch-to-nipple, inframammary fold-to-nipple, and inframammary fold-to-fold projection distances emerged as the most important predictors. The resulting formula (the BREAST-V) showed an adjusted R of 0.73. The estimated expected absolute error on new breasts is 89.7 g (95 percent CI, 62.4 to 119.1 g) and the expected relative error is 18.4 percent (95 percent CI, 12.9 to 24.3 percent). Application of reference formula on the sample yielded worse predictions than those derived by the formula, showing an R of 0.55. The BREAST-V is a reliable tool for predicting small to large breast volumes accurately for use as a complementary device in surgeon evaluation. An app entitled BREAST-V for both iOS and Android devices is currently available for free download in the Apple App Store and Google Play Store. Diagnostic, II.

  17. Giant volume magnetostriction in the Y{sub 2}Fe{sub 17} single crystal at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Nikitin, S. A., E-mail: nikitin@phys.msu.ru; Pankratov, N. Yu.; Smarzhevskaya, A. I.; Politova, G. A. [Physics Faculty, Lomonosov Moscow State University, Moscow 119992 (Russian Federation); Pastushenkov, Yu. G., E-mail: yupast@mail.ru; Skokov, K. P. [Physics Faculty, Tver State University, 170100 Tver (Russian Federation); Moral, A. del [Laboratorio de Magnetismo de Slidos, Departamento de Fisica de Materia Condensada and Instituto de Ciencia de Materiales de Aragn, Facultad de Ciencias, Universidad de Zaragoza-C.S.I.C, E-50009 Zaragoza (Spain)

    2015-05-21

    An investigation of the Y{sub 2}Fe{sub 17} compound belonging to the class of intermetallic alloys of rare-earth and 3d-transition metals is presented. The magnetization, magnetostriction, and thermal expansion of the Y{sub 2}Fe{sub 17} single crystal were studied. The forced magnetostriction and magnetostriction constants were investigated in the temperature range of the magnetic ordering close to the room temperature. The giant field induced volume magnetostriction was discovered in the room temperature region in the magnetic field up to 1.2 T. The contributions of both anisotropic single-ion and isotropic pair exchange interactions to the volume magnetostriction and magnetostriction constants were determined. The experimental results were interpreted within the framework of the Standard Theory of Magnetostriction and the Landau thermodynamic theory. It was found out that the giant values of the volume magnetostriction were caused by the strong dependence of the 3d-electron Coulomb charge repulsion on the deformations and width of the 3d-electron energy band.

  18. VOLUMETRIC LEAK DETECTION IN LARGE UNDERGROUND STORAGE TANKS - VOLUME II: APPENDICES A-E

    Science.gov (United States)

    The program of experiments conducted at Griffiss Air Force Base was devised to expand the understanding of large underground storage tank behavior as it impacts the performance of volumetric leak detection testing. The report addresses three important questions about testing the ...

  19. A METHOD FOR THE RAPID DIALYSIS OF LARGE VOLUMES OF PROTEIN SOLUTIONS

    Science.gov (United States)

    Abramson, H. A.; Grossman, E. B.

    1931-01-01

    A method is described by which moderately large quantities of protein solutions can be dialyzed relatively free of salts within 12 to 24 hours. The use of "Visking" tubes instead of collodion bags is recommended, for speed of dialysis as well as ease of manipulation. PMID:19872600

  20. RADON DIAGNOSTIC MEASUREMENT GUIDANCE FOR LARGE BUILDINGS - VOLUME 1. TECHNICAL REPORT

    Science.gov (United States)

    The report discusses the development of radon diagnostic procedures and mitigation strategies applicable to a variety of large non-residential buildings commonly found in Florida. The investigations document and evaluate the nature of radon occurrence and entry mechanisms for rad...

  1. High Power Compact Single-Frequency Volume Bragg Er-Doped Fiber Laser, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The purpose of this NASA SBIR Phase I proposal is to develop the prototype of a compact single-frequency mode one longitudinal and one transverse mode laser...

  2. Ultra-large scale AFM of lipid droplet arrays: investigating the ink transfer volume in dip pen nanolithography.

    Science.gov (United States)

    Förste, Alexander; Pfirrmann, Marco; Sachs, Johannes; Gröger, Roland; Walheim, Stefan; Brinkmann, Falko; Hirtz, Michael; Fuchs, Harald; Schimmel, Thomas

    2015-05-01

    There are only few quantitative studies commenting on the writing process in dip-pen nanolithography with lipids. Lipids are important carrier ink molecules for the delivery of bio-functional patters in bio-nanotechnology. In order to better understand and control the writing process, more information on the transfer of lipid material from the tip to the substrate is needed. The dependence of the transferred ink volume on the dwell time of the tip on the substrate was investigated by topography measurements with an atomic force microscope (AFM) that is characterized by an ultra-large scan range of 800 × 800 μm(2). For this purpose arrays of dots of the phospholipid1,2-dioleoyl-sn-glycero-3-phosphocholine were written onto planar glass substrates and the resulting pattern was imaged by large scan area AFM. Two writing regimes were identified, characterized of either a steady decline or a constant ink volume transfer per dot feature. For the steady state ink transfer, a linear relationship between the dwell time and the dot volume was determined, which is characterized by a flow rate of about 16 femtoliters per second. A dependence of the ink transport from the length of pauses before and in between writing the structures was observed and should be taken into account during pattern design when aiming at best writing homogeneity. The ultra-large scan range of the utilized AFM allowed for a simultaneous study of the entire preparation area of almost 1 mm(2), yielding good statistic results.

  3. Percutaneous Image-Guided Cryoablation of Challenging Mediastinal Lesions Using Large-Volume Hydrodissection: Technical Considerations and Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Garnon, Julien, E-mail: juliengarnon@gmail.com; Koch, Guillaume, E-mail: Guillaume.koch@gmail.com; Caudrelier, Jean, E-mail: caudjean@yahoo.fr [University Hospital of Strasbourg, Department of Interventional Radiology (France); Ramamurthy, Nitin, E-mail: Nitin-ramamurthy@hotmail.com [Norfolk and Norwich University Hospital, Department of Radiology (United Kingdom); Rao, Pramod, E-mail: pramodrao@me.com [University of Strasbourg, ICube (France); Tsoumakidou, Georgia, E-mail: Georgia.tsoumakidou@chru-strasbourg.fr; Cazzato, Roberto Luigi, E-mail: cazzatorobertoluigi@gmail.com; Gangi, Afshin, E-mail: Afshin.gangi@chru-strasbourg.fr [University Hospital of Strasbourg, Department of Interventional Radiology (France)

    2016-11-15

    ObjectiveThis study was designed to describe the technique of percutaneous image-guided cryoablation with large-volume hydrodissection for the treatment of challenging mediastinal lesions.MethodsBetween March 2014 and June 2015, three patients (mean age 62.7 years) with four neoplastic anterior mediastinal lesions underwent five cryoablation procedures using large-volume hydrodissection. Procedures were performed under general anaesthesia using CT guidance. Lesion characteristics, hydrodissection and cryoablation data, technical success, complications, and clinical outcomes were assessed using retrospective chart review.ResultsLesions (mean size 2.7 cm; range 2–4.3 cm) were in contact with great vessels (n = 13), trachea (n = 3), and mediastinal nerves (n = 6). Hydrodissection was performed intercostally (n = 4), suprasternally (n = 2), transsternally (n = 1), or via the sternoclavicular joint (n = 1) using 1–3 spinal needles over 13.4 (range 7–26) minutes; 450 ml of dilute contrast was injected (range 300–600 ml) and increased mean lesion-collateral structure distance from 1.9 to 7.7 mm. Vulnerable mediastinal nerves were identified in four of five procedures. Technical success was 100 %, with one immediate complication (recurrent laryngeal nerve injury). Mean follow-up period was 15 months. One lesion demonstrated residual disease on restaging PET-CT and was retreated to achieve complete ablation. At last follow-up, two patients remained disease-free, and one patient developed distant disease after 1 year without local recurrence.ConclusionsCryoablation using large-volume hydrodissection is a feasible technique, enabling safe and effective treatment of challenging mediastinal lesions.

  4. Large Deployable Reflector (LDR) system concept and technology definition study. Volume 1: Executive summary, analyses and trades, and system concepts

    Science.gov (United States)

    Agnew, Donald L.; Jones, Peter A.

    1989-01-01

    A study was conducted to define reasonable and representative large deployable reflector (LDR) system concepts for the purpose of defining a technology development program aimed at providing the requisite technological capability necessary to start LDR development by the end of 1991. This volume includes the executive summary for the total study, a report of thirteen system analysis and trades tasks (optical configuration, aperture size, reflector material, segmented mirror, optical subsystem, thermal, pointing and control, transportation to orbit, structures, contamination control, orbital parameters, orbital environment, and spacecraft functions), and descriptions of three selected LDR system concepts. Supporting information is contained in appendices.

  5. Forest Dragon 2: Large-Area Forest Growing Stock Volume Mapping in China, using space borne radar

    OpenAIRE

    Reiche, Johannes; Leiterer, Reik; Cartus, Oliver; Santoro, Maurizio; Schmullius, Christiane; Li, Zengyuan

    2010-01-01

    The creation of large-area forest growing stock volume (GSV) maps of Northeast and Southeast China, based on ERS-1/2 tandem coherence data from the mid 1990s, was aim of the Forest DRAGON 1 project. The evaluation of the map products reveals a reasonable agreement above 70% in terms of forest/ non-forest when compared against freely available Earth Observation products for both NE and SE China. The assessment of forest cover and structure changes in China from the mid 1990s into the current d...

  6. Implication on the core collapse supernova rate from 21 years of data of the Large Volume Detector

    CERN Document Server

    Agafonova, N Y; Antonioli, P; Ashikhmin, V V; Badino, G.; Bari, G; Bertoni, R; Bressan, E; Bruno, G; Dadykin, V L; Dobrynina, E A; Enikeev, R I; Fulgione, W; Galeotti, P; Garbini, M; Ghia, P L; Giusti, P; Gomez, F; Kemp, E; Malgin, A S; Molinario, A; Persiani, R; Pless, I A; Porta, A; Ryasny, V G; Ryazhskaya, O G; Saavedra, O; Sartorelli, G; Shakiryanova, I R; Selvi, M; Trinchero, G C; Vigorito, C; Yakushev, V F; Zichichi, A

    2015-01-01

    The Large Volume Detector (LVD) has been continuously taking data since 1992 at the INFN Gran Sasso National Laboratory. LVD is sensitive to neutrino bursts from gravitational stellar collapses with full detection probability over the Galaxy. We have searched for neutrino bursts in LVD data taken in 7335 days of operation. No evidence of neutrino signals has been found between June 1992 and December 2013. The 90% C.L. upper limit on the rate of core-collapse and failed supernova explosions out to distances of 25 kpc is found to be 0.114/y.

  7. Synthesis of Large-Scale Single-Crystalline Monolayer WS2 Using a Semi-Sealed Method

    Directory of Open Access Journals (Sweden)

    Feifei Lan

    2018-02-01

    Full Text Available As a two-dimensional semiconductor, WS2 has attracted great attention due to its rich physical properties and potential applications. However, it is still difficult to synthesize monolayer single-crystalline WS2 at larger scale. Here, we report the growth of large-scale triangular single-crystalline WS2 with a semi-sealed installation by chemical vapor deposition (CVD. Through this method, triangular single-crystalline WS2 with an average length of more than 300 µm was obtained. The largest one was about 405 μm in length. WS2 triangles with different sizes and thicknesses were analyzed by optical microscope and atomic force microscope (AFM. Their optical properties were evaluated by Raman and photoluminescence (PL spectra. This report paves the way to fabricating large-scale single-crystalline monolayer WS2, which is useful for the growth of high-quality WS2 and its potential applications in the future.

  8. Reliability of estimating the room volume from a single room impulse response

    OpenAIRE

    Kuster, M.

    2008-01-01

    The methods investigated for the room volume estimation are based on geometrical acoustics, eigenmode, and diffuse field models and no data other than the room impulse response are available. The measurements include several receiver positions in a total of 12 rooms of vastly different sizes and acoustic characteristics. The limitations in identifying the pivotal specular reflections of the geometrical acoustics model in measured room impulse responses are examined both theoretically and expe...

  9. Real-time access of large volume imagery through low-bandwidth links

    Science.gov (United States)

    Phillips, James; Grohs, Karl; Brower, Bernard; Kelly, Lawrence; Carlisle, Lewis; Pellechia, Matthew

    2010-04-01

    Providing current, time-sensitive imagery and geospatial information to deployed tactical military forces or first responders continues to be a challenge. This challenge is compounded through rapid increases in sensor collection volumes, both with larger arrays and higher temporal capture rates. Focusing on the needs of these military forces and first responders, ITT developed a system called AGILE (Advanced Geospatial Imagery Library Enterprise) Access as an innovative approach based on standard off-the-shelf techniques to solving this problem. The AGILE Access system is based on commercial software called Image Access Solutions (IAS) and incorporates standard JPEG 2000 processing. Our solution system is implemented in an accredited, deployable form, incorporating a suite of components, including an image database, a web-based search and discovery tool, and several software tools that act in concert to process, store, and disseminate imagery from airborne systems and commercial satellites. Currently, this solution is operational within the U.S. Government tactical infrastructure and supports disadvantaged imagery users in the field. This paper presents the features and benefits of this system to disadvantaged users as demonstrated in real-world operational environments.

  10. Large spin fluctuations and moment-volume coupling in Fe in an fcc environment

    International Nuclear Information System (INIS)

    Acet, M.; Wassermann, E.F.

    1999-01-01

    Complete text of publication follows. Polarized paramagnetic neutron diffraction experiments show that the persisting ferromagnetic correlations above the Curie temperature and the associated magnetic moment of fcc Fe 1-x Ni x alloys with x > 0.30 weaken with increasing temperature reflecting a temperature dependence of the band splitting. In alloys with x ≤ 0.30 the magnetic moment becomes more temperature insensitive and, as the pure Fe concentration is reached, it begins to increase with increasing temperature [1]. The observed property is attributed to a combination of effects arising from spin fluctuations pertinent to itinerant system and to moment-volume fluctuations arising from low-spin to high-spin transitions in systems incorporating a high concentration of fcc-Fe. The experiments are extended to broader fcc stability temperature ranges by using and Fe 0.77 Ni 0.13 Mn 0.07 C 0.03 alloy and further and more clear evidence for the temperature driven low-spin to high-spin transitions is shown. (author) [1] M. Acet, E.F. Wassermann, K. Andersen, A. Murani and O. Schaerpf, Europhys. Lett., 40 (1997) 93

  11. Large-Scale Synthesis of Single-Crystalline Iron Oxide Magnetic Nanorings

    DEFF Research Database (Denmark)

    Jia, Chun-Jiang; Sun, Ling-Dong; Luo, Feng

    2008-01-01

    We present an innovative approach to the production of single-crystal iron oxide nanorings employing a solution-based route. Single-crystal hematite (alpha-Fe2O3) nanorings were synthesized using a double anion-assisted hydrothermal method (involving phosphate and sulfate ions), which can be divi...

  12. Simulation of Containment Pressurization in a Large Break-Loss of Coolant Accident Using Single-Cell and Multicell Models and CONTAIN Code

    Directory of Open Access Journals (Sweden)

    Omid Noori-Kalkhoran

    2016-10-01

    Full Text Available Since the inception of nuclear power as a commercial energy source, safety has been recognized as a prime consideration in the design, construction, operation, maintenance, and decommissioning of nuclear power plants. The release of radioactivity to the environment requires the failure of multiple safety systems and the breach of three physical barriers: fuel cladding, the reactor cooling system, and containment. In this study, nuclear reactor containment pressurization has been modeled in a large break-loss of coolant accident (LB-LOCA by programming single-cell and multicell models in MATLAB. First, containment has been considered as a control volume (single-cell model. In addition, spray operation has been added to this model. In the second step, the single-cell model has been developed into a multicell model to consider the effects of the nodalization and spatial location of cells in the containment pressurization in comparison with the single-cell model. In the third step, the accident has been simulated using the CONTAIN 2.0 code. Finally, Bushehr nuclear power plant (BNPP containment has been considered as a case study. The results of BNPP containment pressurization due to LB-LOCA have been compared between models, final safety analysis report, and CONTAIN code’s results.

  13. High-power, single-frequency, continuous-wave optical parametric oscillator employing a variable reflectivity volume Bragg grating.

    Science.gov (United States)

    Zeil, Peter; Thilmann, Nicky; Pasiskevicius, Valdas; Laurell, Fredrik

    2014-12-01

    A continuous-wave singly-resonant optical parametric oscillator (SRO) with an optimum extraction efficiency, that can be adjusted independent of the pump power, is demonstrated. The scheme employs a variable-reflectivity volume Bragg grating (VBG) as the output coupler of a ring cavity, omitting any additional intra-cavity elements. In this configuration, we obtained a 75%-efficient SRO with a combined signal (19 W @ 1.55 µm) and idler (11 W @ 3.4 µm) output power of 30 W.

  14. Large volume detector telescopes for charged particles at the SIS/ESR accelerator

    International Nuclear Information System (INIS)

    Poggi, G.; Pasquali, G.; Bini, M.; Maurenzig, P.R.; Olmi, A.; Taccetti, N.

    1993-01-01

    A detector system consisting of eight telescopes for light particle and cluster identification is described. It operates in conjunction with the 4π detector at SIS/ESR, spanning a range of polar angles from 6deg up to 90deg. The telescopes identify the atomic number Z and, for particles of Z≤5, also the mass number A over a large energy range, from about 10 A MeV up to 300-600 A MeV, depending on the charge of the detected particle. (orig.)

  15. Large-scale tidal effect on redshift-space power spectrum in a finite-volume survey

    Science.gov (United States)

    Akitsu, Kazuyuki; Takada, Masahiro; Li, Yin

    2017-04-01

    Long-wavelength matter inhomogeneities contain cleaner information on the nature of primordial perturbations as well as the physics of the early Universe. The large-scale coherent overdensity and tidal force, not directly observable for a finite-volume galaxy survey, are both related to the Hessian of large-scale gravitational potential and therefore are of equal importance. We show that the coherent tidal force causes a homogeneous anisotropic distortion of the observed distribution of galaxies in all three directions, perpendicular and parallel to the line-of-sight direction. This effect mimics the redshift-space distortion signal of galaxy peculiar velocities, as well as a distortion by the Alcock-Paczynski effect. We quantify its impact on the redshift-space power spectrum to the leading order, and discuss its importance for ongoing and upcoming galaxy surveys.

  16. No evidence of a threshold in traffic volume affecting road-kill mortality at a large spatio-temporal scale

    Energy Technology Data Exchange (ETDEWEB)

    Grilo, Clara, E-mail: clarabentesgrilo@gmail.com [Departamento de Biología de la Conservación, Estación Biológica de Doñana (EBD-CSIC), Calle Américo Vespucio s/n, E-41092 Sevilla (Spain); Centro Brasileiro de Estudos em Ecologia de Estradas, Departamento de Biologia, Universidade Federal de Lavras, Campus Universitário, 37200-000 Lavras, Minas Gerais (Brazil); Ferreira, Flavio Zanchetta; Revilla, Eloy [Departamento de Biología de la Conservación, Estación Biológica de Doñana (EBD-CSIC), Calle Américo Vespucio s/n, E-41092 Sevilla (Spain)

    2015-11-15

    Previous studies have found that the relationship between wildlife road mortality and traffic volume follows a threshold effect on low traffic volume roads. We aimed at evaluating the response of several species to increasing traffic intensity on highways over a large geographic area and temporal period. We used data of four terrestrial vertebrate species with different biological and ecological features known by their high road-kill rates: the barn owl (Tyto alba), hedgehog (Erinaceus europaeus), red fox (Vulpes vulpes) and European rabbit (Oryctolagus cuniculus). Additionally, we checked whether road-kill likelihood varies when traffic patterns depart from the average. We used annual average daily traffic (AADT) and road-kill records observed along 1000 km of highways in Portugal over seven consecutive years (2003–2009). We fitted candidate models using Generalized Linear Models with a binomial distribution through a sample unit of 1 km segments to describe the effect of traffic on the probability of finding at least one victim in each segment during the study. We also assigned for each road-kill record the traffic of that day and the AADT on that year to test for differences using Paired Student's t-test. Mortality risk declined significantly with traffic volume but varied among species: the probability of finding road-killed red foxes and rabbits occurs up to moderate traffic volumes (< 20,000 AADT) whereas barn owls and hedgehogs occurred up to higher traffic volumes (40,000 AADT). Perception of risk may explain differences in responses towards high traffic highway segments. Road-kill rates did not vary significantly when traffic intensity departed from the average. In summary, we did not find evidence of traffic thresholds for the analysed species and traffic intensities. We suggest mitigation measures to reduce mortality be applied in particular on low traffic roads (< 5000 AADT) while additional measures to reduce barrier effects should take into

  17. No evidence of a threshold in traffic volume affecting road-kill mortality at a large spatio-temporal scale

    International Nuclear Information System (INIS)

    Grilo, Clara; Ferreira, Flavio Zanchetta; Revilla, Eloy

    2015-01-01

    Previous studies have found that the relationship between wildlife road mortality and traffic volume follows a threshold effect on low traffic volume roads. We aimed at evaluating the response of several species to increasing traffic intensity on highways over a large geographic area and temporal period. We used data of four terrestrial vertebrate species with different biological and ecological features known by their high road-kill rates: the barn owl (Tyto alba), hedgehog (Erinaceus europaeus), red fox (Vulpes vulpes) and European rabbit (Oryctolagus cuniculus). Additionally, we checked whether road-kill likelihood varies when traffic patterns depart from the average. We used annual average daily traffic (AADT) and road-kill records observed along 1000 km of highways in Portugal over seven consecutive years (2003–2009). We fitted candidate models using Generalized Linear Models with a binomial distribution through a sample unit of 1 km segments to describe the effect of traffic on the probability of finding at least one victim in each segment during the study. We also assigned for each road-kill record the traffic of that day and the AADT on that year to test for differences using Paired Student's t-test. Mortality risk declined significantly with traffic volume but varied among species: the probability of finding road-killed red foxes and rabbits occurs up to moderate traffic volumes (< 20,000 AADT) whereas barn owls and hedgehogs occurred up to higher traffic volumes (40,000 AADT). Perception of risk may explain differences in responses towards high traffic highway segments. Road-kill rates did not vary significantly when traffic intensity departed from the average. In summary, we did not find evidence of traffic thresholds for the analysed species and traffic intensities. We suggest mitigation measures to reduce mortality be applied in particular on low traffic roads (< 5000 AADT) while additional measures to reduce barrier effects should take into

  18. Paul Scherrer Institute Scientific and Technical Report 2000. Volume VI: Large Research Facilities

    International Nuclear Information System (INIS)

    Foroughi, Fereydoun; Bercher, Renate; Buechli, Carmen; Zumkeller, Lotty

    2001-01-01

    The PSI Department Large Research Facilities (GFA) joins the efforts to provide an excellent research environment to Swiss and foreign research groups on the experimental facilities driven by our high intensity proton accelerator complex. Its divisions care for the running, maintenance and enhancement of the accelerator complex, the primary proton beamlines, the targets and the secondary beams as well as the neutron spallation source SINQ. The division for technical support and coordination provides for technical support to the research facility complementary to the basic logistic available from the department for logistics and marketing. Besides running the facilities, the staff of the department is also involved in theoretical and experimental research projects. Some of them address basic scientific questions mainly concerning the properties of micro- or nanostructured materials: experiments as well as large scale computer simulations of molecular dynamics were performed to investigate nonclassical materials properties. Others are related to improvements or extensions of the capabilities of our facilities. We also report on intriguing results from applications of the neutron capture radiography, the prompt gamma activation method and the isotope production facility at SINQ

  19. Paul Scherrer Institute Scientific and Technical Report 2000. Volume VI: Large Research Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Foroughi, Fereydoun; Bercher, Renate; Buechli, Carmen; Zumkeller, Lotty [eds.

    2001-07-01

    The PSI Department Large Research Facilities (GFA) joins the efforts to provide an excellent research environment to Swiss and foreign research groups on the experimental facilities driven by our high intensity proton accelerator complex. Its divisions care for the running, maintenance and enhancement of the accelerator complex, the primary proton beamlines, the targets and the secondary beams as well as the neutron spallation source SINQ. The division for technical support and coordination provides for technical support to the research facility complementary to the basic logistic available from the department for logistics and marketing. Besides running the facilities, the staff of the department is also involved in theoretical and experimental research projects. Some of them address basic scientific questions mainly concerning the properties of micro- or nanostructured materials: experiments as well as large scale computer simulations of molecular dynamics were performed to investigate nonclassical materials properties. Others are related to improvements or extensions of the capabilities of our facilities. We also report on intriguing results from applications of the neutron capture radiography, the prompt gamma activation method and the isotope production facility at SINQ.

  20. Interpretation of injection-withdrawal tracer experiments conducted between two wells in a large single fracture.

    Science.gov (United States)

    Novakowski, K S; Bickerton, G; Lapcevic, P

    2004-09-01

    Tracer experiments conducted using a flow field established by injecting water into one borehole and withdrawing water from another are often used to establish connections and investigate dispersion in fractured rock. As a result of uncertainty in the uniqueness of existing models used for interpretation, this method has not been widely used to investigate more general transport processes including matrix diffusion or advective solute exchange between mobile and immobile zones of fluid. To explore the utility of the injection-withdrawal method as a general investigative tool and with the intent to resolve the transport processes in a discrete fracture, two tracer experiments were conducted using the injection-withdrawal configuration. The experiments were conducted in a fracture which has a large aperture (>500 microm) and horizontally pervades a dolostone formation. One experiment was conducted in the direction of the hydraulic gradient and the other in the direction opposite to the natural gradient. Two tracers having significantly different values of the free-water diffusion coefficient were used. To interpret the experiments, a hybrid numerical-analytical model was developed which accounts for the arcuate shape of the flow field, advection-dispersion in the fracture, diffusion into the matrix adjacent to the fracture, and the presence of natural flow in the fracture. The model was verified by comparison to a fully analytical solution and to a well-known finite-element model. Interpretation of the tracer experiments showed that when only one tracer, advection-dispersion, and matrix diffusion are considered, non-unique results were obtained. However, by using multiple tracers and by accounting for the presence of natural flow in the fracture, unique interpretations were obtained in which a single value of matrix porosity was estimated from the results of both experiments. The estimate of porosity agrees well with independent measurements of porosity obtained from

  1. Large linear magnetoresistance and shubnikov-de hass oscillations in single crystals of YPdBi heusler topological insulators

    KAUST Repository

    Wang, Wenhong

    2013-07-12

    We report the observation of a large linear magnetoresistance (MR) and Shubnikov-de Hass (SdH) quantum oscillations in single crystals of YPdBi Heusler topological insulators. Owning to the successfully obtained the high-quality YPdBi single crystals, large non-saturating linear MR of as high as 350% at 5K and over 120% at 300K under a moderate magnetic field of 7T is observed. In addition to the large, field-linear MR, the samples exhibit pronounced SdH quantum oscillations at low temperature. Analysis of the SdH data manifests that the high-mobility bulk electron carriers dominate the magnetotransport and are responsible for the observed large linear MR in YPdBi crystals. These findings imply that the Heusler-based topological insulators have superiorities for investigating the novel quantum transport properties and developing the potential applications.

  2. Boron-doped diamond heater and its application to large-volume, high-pressure, and high-temperature experiments.

    Science.gov (United States)

    Shatskiy, Anton; Yamazaki, Daisuke; Morard, Guillaume; Cooray, Titus; Matsuzaki, Takuya; Higo, Yuji; Funakoshi, Ken-ichi; Sumiya, Hitoshi; Ito, Eiji; Katsura, Tomoo

    2009-02-01

    A temperature of 3500 degrees C was generated using a diamond resistance heater in a large-volume Kawai-type high-pressure apparatus. Re and LaCrO(3) have conventionally been used for heaters in high-pressure studies but they cannot generate temperatures higher than 2900 degrees C and make in situ x-ray observations difficult due to their high x-ray absorption. Using a boron-doped diamond heater overcomes these problems and achieves stable temperature generation for pressure over 10 GPa. The heater starting material is a cold-compressed mixture of graphite with boron used to avoid the manufacturing difficulties due to the extreme hardness of diamond. The diamond heater was synthesized in situ from the boron-graphite mixture at temperature of 1600+/-100 degrees C and pressure of 20 GPa. By using the proposed technique, we have employed the diamond heater for high-temperature generation in a large-volume high-pressure apparatus. Achievement of temperatures above 3000 degrees C allows us to measure the melting points of the important constituents in earth's mantle (MgSiO(3), SiO(2), and Al(2)O(3)) and core (Fe and Ni) at extremely high pressures.

  3. Study of stress-strain and volume change behavior of emplaced municipal solid waste using large-scale triaxial testing.

    Science.gov (United States)

    Ramaiah, B J; Ramana, G V

    2017-05-01

    The article presents the stress-strain and volume change behavior, shear strength and stiffness parameters of landfilled municipal solid waste (MSW) collected from two dump sites located in Delhi, India. Over 30 drained triaxial compression (TXC) tests were conducted on reconstituted large-scale specimens of 150mm diameter to study the influence of fiber content, age, density and confining pressure on the shear strength of MSW. In addition, a few TXC tests were also conducted on 70mm diameter specimen to examine the effect of specimen size on the mobilized shear strength. It is observed that the fibrous materials such as textiles and plastics, and their percentage by weight have a significant effect on the stress-strain-volume change behavior, shear strength and stiffness of solid waste. The stress-strain-volume change behavior of MSW at Delhi is qualitatively in agreement with the behavior reported for MSW from different countries. Results of large-scale direct shear tests conducted on MSW with an identical composition used for TXC tests revealed the cross-anisotropic behavior as reported by previous researchers. Effective shear strength parameters of solid waste evaluated from this study is best characterized by ϕ'=39° and c'=0kPa for the limiting strain-based failure criteria of K 0 =0.3+5% axial strain and are in the range of the data reported for MSW from different countries. Data presented in this article is useful for the stress-deformation and stability analysis of the dump sites during their operation as well as closure plans. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. SyPRID sampler: A large-volume, high-resolution, autonomous, deep-ocean precision plankton sampling system

    Science.gov (United States)

    Billings, Andrew; Kaiser, Carl; Young, Craig M.; Hiebert, Laurel S.; Cole, Eli; Wagner, Jamie K. S.; Van Dover, Cindy Lee

    2017-03-01

    The current standard for large-volume (thousands of cubic meters) zooplankton sampling in the deep sea is the MOCNESS, a system of multiple opening-closing nets, typically lowered to within 50 m of the seabed and towed obliquely to the surface to obtain low-spatial-resolution samples that integrate across 10 s of meters of water depth. The SyPRID (Sentry Precision Robotic Impeller Driven) sampler is an innovative, deep-rated (6000 m) plankton sampler that partners with the Sentry Autonomous Underwater Vehicle (AUV) to obtain paired, large-volume plankton samples at specified depths and survey lines to within 1.5 m of the seabed and with simultaneous collection of sensor data. SyPRID uses a perforated Ultra-High-Molecular-Weight (UHMW) plastic tube to support a fine mesh net within an outer carbon composite tube (tube-within-a-tube design), with an axial flow pump located aft of the capture filter. The pump facilitates flow through the system and reduces or possibly eliminates the bow wave at the mouth opening. The cod end, a hollow truncated cone, is also made of UHMW plastic and includes a collection volume designed to provide an area where zooplankton can collect, out of the high flow region. SyPRID attaches as a saddle-pack to the Sentry vehicle. Sentry itself is configured with a flight control system that enables autonomous survey paths to low altitudes. In its verification deployment at the Blake Ridge Seep (2160 m) on the US Atlantic Margin, SyPRID was operated for 6 h at an altitude of 5 m. It recovered plankton samples, including delicate living larvae, from the near-bottom stratum that is seldom sampled by a typical MOCNESS tow. The prototype SyPRID and its next generations will enable studies of plankton or other particulate distributions associated with localized physico-chemical strata in the water column or above patchy habitats on the seafloor.

  5. SU-F-T-538: CyberKnife with MLC for Treatment of Large Volume Tumors: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Bichay, T; Mayville, A [Mercy Health, Saint Mary’s, Grand Rapids, MI (United States)

    2016-06-15

    Purpose: CyberKnife is a well-documented modality for SRS and SBRT treatments. Typical tumors are small and 1–5 fractions are usually used. We determined the feasibility of using CyberKnife, with an InCise multileaf collimator option, for larger tumors undergoing standard dose and fractionation. The intent was to understand the limitation of using this modality for other external beam radiation treatments. Methods: Five tumors from different anatomical sites with volumes from 127.8 cc to 1,320.5 cc were contoured and planned on a Multiplan V5.1 workstation. The target average diameter ranged from 7 cm to 13 cm. The dose fractionation was 1.8–2.0 Gy/fraction and 25–45 fractions for total doses of 45–81 Gy. The sites planned were: pancreas, head and neck, prostate, anal, and esophagus. The plans were optimized to meet conventional dose constraints based on various RTOG protocols for conventional fractionation. Results: The Multiplan treatment planning system successfully generated clinically acceptable plans for all sites studied. The resulting dose distributions achieved reasonable target coverage, all greater than 95%, and satisfactory normal tissue sparing. Treatment times ranged from 9 minutes to 38 minutes, the longest being a head and neck plan with dual targets receiving different doses and with multiple adjacent critical structures. Conclusion: CyberKnife, with the InCise multileaf collimation option, can achieve acceptable dose distributions in large volume tumors treated with conventional dose and fractionation. Although treatment times are greater than conventional accelerator time; target coverage and dose to critical structures can be kept within a clinically acceptable range. While time limitations exist, when necessary CyberKnife can provide an alternative to traditional treatment modalities for large volume tumors.

  6. The volumes and transcript counts of single cells reveal concentration homeostasis and capture biological noise.

    NARCIS (Netherlands)

    Kempe, H.; Schwabe, A.; Crémazy, F.; Verschure, P.J.; Bruggeman, F.J.

    2015-01-01

    Transcriptional stochasticity can be measured by counting the number of mRNA molecules per cell. Cell-to-cell variability is best captured in terms of concentration rather than molecule counts, because reaction rates depend on concentrations. We combined single-molecule mRNA counting with

  7. New techniques for high pressure falling sphere viscosimetry in DIA-type large volume presses

    Science.gov (United States)

    Mueller, Hans J.; Beckmann, Felix; Dobson, David P.; Hunt, Simon A.; Lathe, Christian; Stroncik, Nicole

    2014-07-01

    Here we report recent technical advances that enable viscosity measurements in two DIA-type multi-anvil apparatus with a maximum of 250 tons and 1750 tons. We anticipate that this system will enable viscosity measurements for the pressures up to about 30 GPa. The deformation of the cell assemblies were analyzed by X-ray absorption tomography at beamline W II at DESY/HASYLAB after the high pressure runs. This analysis gave considerable insights into strategies for improving the cell assembly with the result that the optimized assemblies could be used at much higher pressures without blow-outs. We demonstrate using of X-ray transparent cubic boron nitride-anvils (single-stage DIA) and slotted carbide anvils (double-stage DIA) to make the whole melting chamber accessible for the high pressure X-radiography system. Results are demonstrated with viscosity measurements following Stokes' Law by evaluation of X-radiography sequences taken by a camera equipped with a charge-coupled device sensor (CCD-camera) at pressures of 5 GPa as well as 10 GPa and temperatures of 1890 K.

  8. Development and calibration of large volume proton-recoil counters for neutron spectrometry in radiological protection

    International Nuclear Information System (INIS)

    Delafield, H.J.; Birch, R.

    1988-08-01

    A transportable neutron spectrometry system of high sensitivity, based on four cylindrical proton-recoil proportional counters, has been developed for the high-resolution measurement of neutron spectra in the working environment at dose-equivalent rates in the range 5-50 μSv h -1 . The system uses modern compact electronics to provide simultaneous data acquisition with a single multichannel analyser. This report describes in detail the research and development undertaken to produce a set of four cylindrical counters to cover the neutron energy-range from about 50 keV to 2 MeV. Counter studies were made to optimize the type and size of anode wire, the gas fillings and manufacturing procedure. The counters were calibrated at the National Physical Laboratory using monoenergetic neutrons, incident side-on and end-on, to provide measured response functions, energy and fluence calibrations. The system will generally be used together with a set of multispheres, to measure the dose-equivalent below 50 keV, and an α-recoil proportional counter to extend the spectral measurement up to 15 MeV. (author)

  9. Potential of electrical gas discharges for pollution control of large gas volumes

    International Nuclear Information System (INIS)

    Kogelschatz, U.

    1997-01-01

    Non-equilibrium gas discharges in many cases offer an innovative approach to the solution cf industrial air pollution problems. Negative corona discharges are used in electrostatic precipitators to collect dust and fly ash particles. Pulsed positive streamer coronas, dielectric-barrier discharges and possibly also flow-stabilised high pressure glow discharges are emerging technologies for the destruction of air pollutants like nitrogen oxides and sulfur dioxide in flue gases and volatile organic compounds (VOCs) in industrial effluents. The different discharge types are discussed with special emphasis on their potential for upscaling. Major applications are expected particularly in the removal of dilute concentrations of air pollutants, in odour control and in the simultaneous removal of different pollutants. Dielectric-barrier discharges exhibit disposal efficiencies similar to those of pulsed positive streamer coronas and require less sophisticated feeding circuits in large-scale industrial applications. (author)

  10. Periodic long-range transport in a large volume dc glow discharge dusty plasma

    International Nuclear Information System (INIS)

    Thomas, Edward Jr.; Amatucci, William E.; Compton, Christopher; Christy, Brian; Jackson, Jon David

    2003-01-01

    In an earlier paper, the authors reported on observations of a variety of particle transport phenomena observed in DUPLEX--the DUsty PLasma EXperiment at the Naval Research Laboratory [E. Thomas, Jr., W. E. Amatucci, C. Compton, and B. Christy, Phys. Plasmas 9, 3154 (2002)]. DUPLEX is a large, transparent polycarbonate cylinder that is 40 cm in radius and 80 cm in height. dc glow discharge argon plasmas are generated in DUPLEX. In this paper, the authors expand upon one particular feature of particle transport in DUPLEX, the long-range (i.e., greater than 15 cm), periodic (T∼2.5 min) transport of suspended alumina particles through the plasma. A detailed description of this particle motion through the plasma is presented. Finally, a qualitative model describing the phenomena that lead to this transport is also given

  11. Critical joints in large composite primary aircraft structures. Volume 2: Technology demonstration test report

    Science.gov (United States)

    Bunin, Bruce L.

    1985-01-01

    A program was conducted to develop the technology for critical structural joints in composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. The results of four large composite multirow bolted joint tests are presented. The tests were conducted to demonstrate the technology for critical joints in highly loaded composite structure and to verify the analytical methods that were developed throughout the program. The test consisted of a wing skin-stringer transition specimen representing a stringer runout and skin splice on the wing lower surface at the side of the fuselage attachment. All tests were static tension tests. The composite material was Toray T-300 fiber with Ciba-Geigy 914 resin in 10 mil tape form. The splice members were metallic, using combinations of aluminum and titanium. Discussions are given of the test article, instrumentation, test setup, test procedures, and test results for each of the four specimens. Some of the analytical predictions are also included.

  12. Critical joints in large composite primary aircraft structures. Volume 1: Technical summary

    Science.gov (United States)

    Bunin, Bruce L.

    1985-01-01

    A program was conducted at Douglas Aircraft Company to develop the technology for critical joints in composite wing structure that meets all the design requirements of a 1990 commercial transport aircraft. In fulfilling this objective, analytical procedures for joint design and analysis were developed during Phase 1 of the program. Tests were conducted at the element level to supply the empirical data required for methods development. Large composite multirow joints were tested to verify the selected design concepts and for correlation with analysis predictions. The Phase 2 program included additional tests to provide joint design and analysis data, and culminated with several technology demonstration tests of a major joint area representative of a commercial transport wing. The technology demonstration program of Phase 2 is discussed. The analysis methodology development, structural test program, and correlation between test results and analytical strength predictions are reviewed.

  13. Marvel-ous Dwarfs: Results from Four Heroically Large Simulated Volumes of Dwarf Galaxies

    Science.gov (United States)

    Munshi, Ferah; Brooks, Alyson; Weisz, Daniel; Bellovary, Jillian; Christensen, Charlotte

    2018-01-01

    We present results from high resolution, fully cosmological simulations of cosmic sheets that contain many dwarf galaxies. Together, they create the largest collection of simulated dwarf galaxies to date, with z=0 stellar masses comparable to the LMC or smaller. In total, we have simulated almost 100 luminous dwarf galaxies, forming a sample of simulated dwarfs which span a wide range of physical (stellar and halo mass) and evolutionary properties (merger history). We show how they can be calibrated against a wealth of observations of nearby galaxies including star formation histories, HI masses and kinematics, as well as stellar metallicities. We present preliminary results answering the following key questions: What is the slope of the stellar mass function at extremely low masses? Do halos with HI and no stars exist? What is the scatter in the stellar to halo mass relationship as a function of dwarf mass? What drives the scatter? With this large suite, we are beginning to statistically characterize dwarf galaxies and identify the types and numbers of outliers to expect.

  14. Single Cell Transfection through Precise Microinjection with Quantitatively Controlled Injection Volumes

    Science.gov (United States)

    Chow, Yu Ting; Chen, Shuxun; Wang, Ran; Liu, Chichi; Kong, Chi-Wing; Li, Ronald A.; Cheng, Shuk Han; Sun, Dong

    2016-04-01

    Cell transfection is a technique wherein foreign genetic molecules are delivered into cells. To elucidate distinct responses during cell genetic modification, methods to achieve transfection at the single-cell level are of great value. Herein, we developed an automated micropipette-based quantitative microinjection technology that can deliver precise amounts of materials into cells. The developed microinjection system achieved precise single-cell microinjection by pre-patterning cells in an array and controlling the amount of substance delivered based on injection pressure and time. The precision of the proposed injection technique was examined by comparing the fluorescence intensities of fluorescent dye droplets with a standard concentration and water droplets with a known injection amount of the dye in oil. Injection of synthetic modified mRNA (modRNA) encoding green fluorescence proteins or a cocktail of plasmids encoding green and red fluorescence proteins into human foreskin fibroblast cells demonstrated that the resulting green fluorescence intensity or green/red fluorescence intensity ratio were well correlated with the amount of genetic material injected into the cells. Single-cell transfection via the developed microinjection technique will be of particular use in cases where cell transfection is challenging and genetically modified of selected cells are desired.

  15. Effects of a Single Bout of Resistance Exercise in Different Volumes on Endothelium Adaptations in Healthy Animals.

    Science.gov (United States)

    Mota, Marcelo Mendonça; Silva, Tharciano Luiz Teixeira Braga da; Macedo, Fabricio Nunes; Mesquita, Thássio Ricardo Ribeiro; Quintans, Lucindo José; Santana-Filho, Valter Joviniano de; Lauton-Santos, Sandra; Santos, Márcio Roberto Viana

    2017-05-01

    Resistance exercise (RE) has been recommended for patients with cardiovascular diseases. Recently, a few studies have demonstrated that the intensity of a single bout of RE has an effect on endothelial adaptations to exercise. However, there is no data about the effects of different volumes of RE on endothelium function. The aim of the study was to evaluate the effects of different volumes of RE in a single bout on endothelium-dependent vasodilatation and nitric oxide (NO) synthesis in the mesenteric artery of healthy animals. Male Wistar rats were divided into three groups: Control (Ct); low-volume RE (LV, 5 sets x 10 repetitions) and high-volume RE (HV, 15 sets x 10 repetitions). The established intensity was 70% of the maximal repetition test. After the exercise protocol, rings of mesenteric artery were used for assessment of vascular reactivity, and other mesenteric arteries were prepared for detection of measure NO production by DAF-FM fluorescence. Insulin responsiveness on NO synthesis was evaluated by stimulating the vascular rings with insulin (10 nM). The maximal relaxation response to insulin increased in the HV group only as compared with the Ct group. Moreover, the inhibition of nitric oxide synthesis (L-NAME) completely abolished the insulin-induced vasorelaxation in exercised rats. NO production showed a volume-dependent increase in the endothelial and smooth muscle layer. In endothelial layer, only Ct and LV groups showed a significant increase in NO synthesis when compared to their respective group under basal condition. On the other hand, in smooth muscle layer, NO fluorescence increased in all groups when compared to their respective group under basal condition. Our results suggest that a single bout of RE promotes vascular endothelium changes in a volume-dependent manner. The 15 sets x 10 repetitions exercise plan induced the greatest levels of NO synthesis. O exercício resistido (ER) tem sido recomendado para pacientes com doen

  16. Estimate Landslide Volume with Genetic Algorithms and Image Similarity Method from Single Satellite Image

    Science.gov (United States)

    Yu, Ting-To

    2013-04-01

    It is important to acquire the volume of landslide in short period of time. For hazard mitigation and also emergency response purpose, the traditional method takes much longer time than expected. Due to the weather limit, traffic accessibility and many regulations of law, it take months to handle these process before the actual carry out of filed work. Remote sensing imagery can get the data as long as the visibility allowed, which happened only few day after the event. While traditional photometry requires a stereo pairs images to produce the post event DEM for calculating the change of volume. Usually have to wait weeks or even months for gathering such data, LiDAR or ground GPS measurement might take even longer period of time with much higher cost. In this study we use one post event satellite image and pre-event DTM to compare the similarity between these by alter the DTM with genetic algorithms. The outcome of smartest guess from GAs shall remove or add exact values of height at each location, which been converted into shadow relief viewgraph to compare with satellite image. Once the similarity threshold been make then the guessing work stop. It takes only few hours to finish the entire task, the computed accuracy is around 70% by comparing to the high resolution LiDAR survey at a landslide, southern Taiwan. With extra GCPs, the estimate accuracy can improve to 85% and also within few hours after the receiving of satellite image. Data of this demonstration case is a 5 m DTM at 2005, 2M resolution FormoSat optical image at 2009 and 5M LiDAR at 2010. The GAs and image similarity code is developed on Matlab at windows PC.

  17. Highly tunable large core single-mode liquid crystal photonic bandgap fiber

    DEFF Research Database (Denmark)

    Alkeskjold, Thomas Tanggaard; Lægsgaard, Jesper; Bjarklev, Anders Overgaard

    2006-01-01

    We demonstrate a highly tunable photonic bandgap fiber, which has a large-core diameter of 25 mu m and an effective mode area of 440 mu m(2). The tunability is achieved by infiltrating the air holes of a photonic crystal fiber with an optimized liquid-crystal mixture having a large temperature...

  18. Closed system generation of dendritic cells from a single blood volume for clinical application in immunotherapy

    NARCIS (Netherlands)

    Elias, M; van Zanten, J; Hospers, GAP; Setroikromo, A; de Jong, MA; de Leij, LFMH; Mulder, NH

    2005-01-01

    Dendritic cells (DC) used for clinical trials should be processed oil a large scale conforming to current good manufacturing practice (cGM P) guidelines. The aim of this study was to develop a protocol for clinical grade generation of immature DC in a closed-systern. Aphereses were performed with

  19. Basic study for a large AC current supply with a single phase air-core Bi2223 high temperature superconducting transformer

    Science.gov (United States)

    Nanato, N.; Kishi, N.; Tanaka, Y.; Kondo, M.

    2017-07-01

    The authors have been developing a compact power supply with a single-phase Bi2223 high temperature superconducting (HTS) transformer. The conventional transformer has an iron-core for enhancing magnetic coupling between its primary coil and secondary one. However, the iron-core has great majority of size and weight of the transformer and therefore it is desirable to be removed for a smaller and lighter transformer. In this paper, the authors propose an air-core HTS transformer for a more compact power supply than the conventional one. As experimental results, it is shown that appropriate design of the air-core transformer has a possibility to decrease the weight and volume of the large AC current supply.

  20. Testing of the large bore single aperture 1-meter superconducting dipoles made with phenolic inserts

    CERN Document Server

    Boschmann, H; Dubbeldam, R L; Kirby, G A; Lucas, J; Ostojic, R; Russenschuck, Stephan; Siemko, A; Taylor, T M; Vanenkov, I; Weterings, W

    1998-01-01

    Two identical single aperture 1-metre superconducting dipoles have been built in collaboration with HMA Power Systems and tested at CERN. The 87.8 mm aperture magnets feature a single layer coil wound using LHC main dipole outer layer cable, phenolic spacer type collars, and a keyed two part structural iron yoke. The magnets are designed as models of the D1 separation dipole in the LHC experimental insertions, whose nominal field is 4.5 T at 4.5 K. In this report we present the test results of the two magnets at 4.3 K and 1.9 K.

  1. Large-Scale Single Particle and Cell Trapping based on Rotating Electric Field Induced-Charge Electroosmosis.

    Science.gov (United States)

    Wu, Yupan; Ren, Yukun; Tao, Ye; Hou, Likai; Jiang, Hongyuan

    2016-12-06

    We propose a simple, inexpensive microfluidic chip for large-scale trapping of single particles and cells based on induced-charge electroosmosis in a rotating electric field (ROT-ICEO). A central floating electrode array, was placed in the center of the gap between four driving electrodes with a quadrature configuration and used to immobilize single particles or cells. Cells were trapped on the electrode array by the interaction between ROT-ICEO flow and buoyancy flow. We experimentally optimized the efficiency of trapping single particles by investigating important parameters like particle or cell density and electric potential. Experimental and numerical results showed good agreement. The operation of the chip was verified by trapping single polystyrene (PS) microspheres with diameters of 5 and 20 μm and single yeast cells. The highest single particle occupancy of 73% was obtained using a floating electrode array with a diameter of 20 μm with an amplitude voltage of 5 V and frequency of 10 kHz for PS microbeads with a 5-μm diameter and density of 800 particles/μL. The ROT-ICEO flow could hold cells against fluid flows with a rate of less than 0.45 μL/min. This novel, simple, robust method to trap single cells has enormous potential in genetic and metabolic engineering.

  2. Comparison of pathogen DNA isolation methods from large volumes of whole blood to improve molecular diagnosis of bloodstream infections.

    Directory of Open Access Journals (Sweden)

    Anne J M Loonen

    Full Text Available For patients suffering from bloodstream infections (BSI molecular diagnostics from whole blood holds promise to provide fast and adequate treatment. However, this approach is hampered by the need of large blood volumes. Three methods for pathogen DNA isolation from whole blood were compared, i.e. an enzymatic method (MolYsis, 1-5 ml, the novel non-enzymatic procedure (Polaris, 1-5 ml, and a method that does not entail removal of human DNA (Triton-Tris-EDTA EasyMAG, 200 µl. These methods were evaluated by processing blood spiked with 0-1000 CFU/ml of Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans. Downstream detection was performed with real-time PCR assays. Polaris and MolYsis processing followed by real-time PCRs enabled pathogen detection at clinically relevant concentrations of 1-10 CFU/ml blood. By increasing sample volumes, concurrent lower cycle threshold (Ct values were obtained at clinically relevant pathogen concentrations, demonstrating the benefit of using larger blood volumes. A 100% detection rate at a concentration of 10 CFU/ml for all tested pathogens was obtained with the Polaris enrichment, whereas comparatively lower detection rates were measured for MolYsis (50-67% and EasyMAG (58-79%. For the samples with a concentration of 1 CFU/ml Polaris resulted in most optimal detection rates of 70-75% (MolYsis 17-50% and TTE-EasyMAG 20-36%. The Polaris method was more reproducible, less labour intensive, and faster (45 minutes (including Qiagen DNA extraction vs. 2 hours (MolYsis. In conclusion, Polaris and MolYsis enrichment followed by DNA isolation and real-time PCR enables reliable and sensitive detection of bacteria and fungi from 5 ml blood. With Polaris results are available within 3 hours, showing potential for improved BSI diagnostics.

  3. Multiple Small Diameter Drillings Increase Femoral Neck Stability Compared with Single Large Diameter Femoral Head Core Decompression Technique for Avascular Necrosis of the Femoral Head.

    Science.gov (United States)

    Brown, Philip J; Mannava, Sandeep; Seyler, Thorsten M; Plate, Johannes F; Van Sikes, Charles; Stitzel, Joel D; Lang, Jason E

    2016-10-26

    Femoral head core decompression is an efficacious joint-preserving procedure for treatment of early stage avascular necrosis. However, postoperative fractures have been described which may be related to the decompression technique used. Femoral head decompressions were performed on 12 matched human cadaveric femora comparing large 8mm single bore versus multiple 3mm small drilling techniques. Ultimate failure strength of the femora was tested using a servo-hydraulic material testing system. Ultimate load to failure was compared between the different decompression techniques using two paired ANCOVA linear regression models. Prior to biomechanical testing and after the intervention, volumetric bone mineral density was determined using quantitative computed tomography to account for variation between cadaveric samples and to assess the amount of bone disruption by the core decompression. Core decompression, using the small diameter bore and multiple drilling technique, withstood significantly greater load prior to failure compared with the single large bore technique after adjustment for bone mineral density (pcore decompression techniques. When considering core decompression for the treatment of early stage avascular necrosis, the multiple small bore technique removed less bone volume, thereby potentially leading to higher load to failure.

  4. THEORETICAL AND EXPERIMENTAL INVESTIGATION OF THE MAGNETOELECTRIC SYSTEM, WHICH RECOGNIZES THE LARGE OF SUNS OF A SINGLE-SPIRAL CLASSIFIER

    Directory of Open Access Journals (Sweden)

    A. N. Matsui

    2018-02-01

    Full Text Available Purpose. The aim of the work is to create a magnetoelectric system with permanent magnets, which perceives the coarse size of the sand of a single-helix classifier, by establishing the connection of the output signal with the measured quantity, eliminating the effect of disturbances on the result and justifying its parameters. Methodology. The studies carried out on the basis of the use of methods of the theory of electrical engineering, magnetic systems with permanent magnets, galvanomagnetic transducers, probabilities, random processes, statistics, regression analysis, sensitivity, differential calculus, rock magnetism, determination of the physical properties of matrix material when impurities are added to it with others explicitly expressed properties, the classification of enrichment products. Findings. The process of the rate of change of the volume of solid in a controlled volume of space through which the sand material moves is described mathematically. The limits of the volume of the controlled volume at which the sensitivity is still sufficient are determined. The theoretical dependences of the rate of change of the solid volume in the controlled volume on the size of the sands at different speeds are obtained. It is established that the state of the controlled volume is best estimated by the magnetic method. A magnetoelectric system with permanent magnets has been developed, which has optimal parameter values and an induction winding containing up to 25,000 turns, and in one of the pole pieces of which a Hall transducer is installed in a continuous slot. The magnetic system near the air gap creates in the material a magnetic field 5 × 20 × 60 mm in size with almost the same intensity. Ed. The magnetoelectric system practically changes linearly with the increase in the size of the material. It depends on the content of magnetic iron in the solid, which is compensated by the use of the signal from the Hall converter. Correlation

  5. Plasma properties in a large-volume, cylindrical and asymmetric radio-frequency capacitively coupled industrial-prototype reactor

    Science.gov (United States)

    Lazović, Saša; Puač, Nevena; Spasić, Kosta; Malović, Gordana; Cvelbar, Uroš; Mozetič, Miran; Radetić, Maja; Petrović, Zoran Lj

    2013-02-01

    We have developed a large-volume low-pressure cylindrical plasma reactor with a size that matches industrial reactors for treatment of textiles. It was shown that it efficiently produces plasmas with only a small increase in power as compared with a similar reactor with 50 times smaller volume. Plasma generated at 13.56 MHz was stable from transition to streamers and capable of long-term continuous operation. An industrial-scale asymmetric cylindrical reactor of simple design and construction enabled good control over a wide range of active plasma species and ion concentrations. Detailed characterization of the discharge was performed using derivative, Langmuir and catalytic probes which enabled determination of the optimal sets of plasma parameters necessary for successful industry implementation and process control. Since neutral atomic oxygen plays a major role in many of the material processing applications, its spatial profile was measured using nickel catalytic probe over a wide range of plasma parameters. The spatial profiles show diffusion profiles with particle production close to the powered electrode and significant wall losses due to surface recombination. Oxygen atom densities range from 1019 m-3 near the powered electrode to 1017 m-3 near the wall. The concentrations of ions at the same time are changing from 1016 to the 1015 m-3 at the grounded chamber wall.

  6. Large-volume excitation of air, argon, nitrogen and combustible mixtures by thermal jets produced by nanosecond spark discharges

    Science.gov (United States)

    Stepanyan, Sergey; Hayashi, Jun; Salmon, Arthur; Stancu, Gabi D.; Laux, Christophe O.

    2017-04-01

    This work presents experimental observations of strong expanding thermal jets following the application of nanosecond spark discharges. These jets propagate in a toroidal shape perpendicular to the interelectrode axis, with high velocities of up to 30 m s-1 and over distances of the order of a cm. Their propagation length is much larger than the thermal expansion region produced by the conventional millisecond sparks used in car engine ignition, thus greatly improving the volumetric excitation of gas mixtures. The shape and velocity of the jets is found to be fairly insensitive to the shape of the electrodes. In addition, their spatial extent is found to increase with the number of nanosecond sparks and with the discharge voltage, and to decrease slightly with the pressure between 1 and 7 atm at constant applied voltage. Finally, this thermal jet phenomenon is observed in experiments conducted with many types of gas mixtures, including air, nitrogen, argon, and combustible CH4/air mixtures. This makes nanosecond repetitively pulsed discharges particularly attractive for aerodynamic flow control or plasma-assisted combustion because of their ability to excite large volumes of gas, typically about 100 times the volume of the discharge.

  7. Pretherapy metabolic tumour volume is an independent predictor of outcome in patients with diffuse large B-cell lymphoma

    Energy Technology Data Exchange (ETDEWEB)

    Sasanelli, Myriam; Meignan, Michel; Haioun, Corinne; Itti, Emmanuel [Paris-Est University, Nuclear Medicine and Lymphoid Malignancies Unit, Henri Mondor Hospital, Creteil (France); Berriolo-Riedinger, Alina; Casasnovas, Rene-Olivier [Nuclear Medicine and Hematology, Georges-Francois Leclerc Center, Le Bocage Hospital, Dijon (France); Biggi, Alberto; Gallamini, Andrea [Nuclear Medicine and Hematology, Santa Croce e Carle Hospital, Cuneo (Italy); Siegel, Barry A.; Cashen, Amanda F. [Washington University School of Medicine, Nuclear Medicine and Oncology, Siteman Cancer Center, St. Louis, MO (United States); Vera, Pierre; Tilly, Herve [Nuclear Medicine and Hematology, Henri Becquerel Center, Rouen (France); Versari, Annibale [Nuclear Medicine, Santa Maria Nuova Hospital-IRCCS, Reggio Emilia (Italy)

    2014-11-15

    We investigated the prognostic value of total metabolic tumour volume (TMTV) in diffuse large B-cell lymphoma (DLBCL). TMTV was measured in 114 patients with newly diagnosed DLBCL who underwent {sup 18}F-FDG PET/CT at baseline before immunochemotherapy. TMTV was computed by summing the volumes of all lymphomatous lesions after applying the local SUVmax threshold of 41 % using semiautomatic software. Prognostic value was assessed by Kaplan-Meier estimates of progression-free survival (PFS) and overall survival (OS). Median follow-up was 39 months. Average pretherapy TMTV was 509 ± 568 cm{sup 3}. The 3-year estimates of PFS were 77 % in the low metabolic burden group (TMTV ≤550 cm{sup 3}) and 60 % in the high metabolic burden group (TMTV >550 cm{sup 3}, p = 0.04), and prediction of OS was even better (87 % vs. 60 %, p = 0.0003). Cox regression showed independence of TMTV for OS prediction (p = 0.002) compared with other pretherapy indices of tumour burden, such as tumour bulk and the International Prognostic Index. Pretherapy TMTV is an independent predictor of outcome in patients with DLBCL. (orig.)

  8. Fully Streched Single DNA Molecules in a Nanofluidic Chip Show Large-Scale Structural Variation

    DEFF Research Database (Denmark)

    Pedersen, Jonas Nyvold; Marie, Rodolphe; Bauer, D. L.

    2013-01-01

    When stretching and imaging DNA molecules in nanofluidic devices, it is important to know the relation between the physical length as measured in the lab and the distance along the contour of the DNA. Here a single DNA molecule longer than 1 Mbp is loaded into a nanofluidic device consisting of two...

  9. Mechanical properties of mammalian single smooth muscle cells. I. A low cost large range microforce transducer.

    NARCIS (Netherlands)

    J.J. Glerum (Jacobus); R. van Mastrigt (Ron)

    1990-01-01

    textabstractA transducer has been developed for measuring the minute forces generated during isometric contractions (1.0-10.0 microN) of single smooth muscle cells from the pig urinary bladder and the human uterus. In addition to its high sensitivity, resolution and stability (100 mV microN-1, and

  10. A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device.

    Science.gov (United States)

    Srivastava, P K; Singh, S K; Sanyasi, A K; Awasthi, L M; Mattoo, S K

    2016-07-01

    This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

  11. Structural Transformation in Inverse-Perovskite REPt3B (RE = Sm and Gd-Tm) Associated with Large Volume Reduction.

    Science.gov (United States)

    Mondal, Sudipta; Mazumdar, Chandan; Ranganathan, Rajarao; Avdeev, Maxim

    2017-07-17

    In this work, we report the structural phase transformation of tetragonal inverse-perovskite REPt 3 B (RE = Sm, and Gd-Tm) compounds to cubic perovskite structure, with a large volume reduction of about 9% (reduction of the c axis, ∼17%; increase in the a axis, ∼5%). The structural stability of the cubic phase, however, could only be maintained by lowering the lattice parameter of the off-stoichiometric REPt 3 B x (x magnetic transition temperatures in the tetragonal and cubic phases. The different physical properties of these two phases demonstrate the interrelationship between the crystal chemistry and the physics of the system. The synthetic route to cubic REPt 3 B x identified in this work may be utilized to prepare new ternary rare-earth intermetallics in a cubic perovksite form, which was previously found to facilitate unconventional superconductivity.

  12. A 5 kA pulsed power supply for inductive and plasma loads in large volume plasma device

    Science.gov (United States)

    Srivastava, P. K.; Singh, S. K.; Sanyasi, A. K.; Awasthi, L. M.; Mattoo, S. K.

    2016-07-01

    This paper describes 5 kA, 12 ms pulsed power supply for inductive load of Electron Energy Filter (EEF) in large volume plasma device. The power supply is based upon the principle of rapid sourcing of energy from the capacitor bank (2.8 F/200 V) by using a static switch, comprising of ten Insulated Gate Bipolar Transistors (IGBTs). A suitable mechanism is developed to ensure equal sharing of current and uniform power distribution during the operation of these IGBTs. Safe commutation of power to the EEF is ensured by the proper optimization of its components and by the introduction of over voltage protection (>6 kV) using an indigenously designed snubber circuit. Various time sequences relevant to different actions of power supply, viz., pulse width control and repetition rate, are realized through optically isolated computer controlled interface.

  13. Rapid MR imaging of the liver. Comparison of twelve techniques for single breath-hold whole volume acquisition

    International Nuclear Information System (INIS)

    Naganawa, Shinji; Jenner, Goeran; Cooper, T.G.; Potchen, E.J.; Ishigaki, Takeo

    1994-01-01

    Twelve magnetic resonance imaging pulse sequences for single breath-hold whole volume acquisition of the liver were evaluated on volunteers. Liver and spleen contrast to noise ratio (C/N), overall image quality, and grade of artifacts were compared. The 12 sequences included T 2 -weighted fast spin echo (FSE) with or without fat suppression (FS), fast multiplanar spoiled gradient recalled imaging (FMPSPGR), fast gradient recalled imaging without preparation pulses (FGR), FGR with inversion recovery preparation pulse nulling the liver or fat (IR-FGR-L and IR-FGR-F), FGR with driven equilibrium preparation pulse (DE-FGR), single shot moderately or heavily T 2 -weighted spin echo echo planar imaging (SE-EPI-mT2 and SE-EPI-hT2), multi-shot moderately T 2 -weighted spin echo echo planar imaging (multi-shot SE-EPI-mT2), inversion recovery EPI, and gradient echo EPI. In the quantitative analysis, FSE + FS showed a significantly higher C/N ratio than the others (p<0.05). In the qualitative evaluation, DE-prepFGR, and single and multi-shot SE-EPI-mT2 had good results, as did FSE and FSE + FS. Further studies should be conducted to determine whether or not these breath-hold sequences can obviate current conventional non-breath-hold sequences. (author)

  14. The optimal anatomic site for a single slice to estimate the total volume of visceral adipose tissue by using the quantitative computed tomography (QCT) in Chinese population.

    Science.gov (United States)

    Cheng, X; Zhang, Y; Wang, C; Deng, W; Wang, L; Duanmu, Y; Li, K; Yan, D; Xu, L; Wu, C; Shen, W; Tian, W

    2018-03-20

    To investigate the relationship between the cross-sectional visceral adipose tissue (VAT) areas at different anatomic sites and the total VAT volume in a healthy Chinese population using quantitative computed tomography (QCT), and to identify the optimal anatomic site for a single slice to estimate the total VAT volume. A total of 389 healthy Chinese subjects aged 19-63 years underwent lumbar spine QCT scans. The cross-sectional area of total adipose tissue and VAT were measured using the tissue composition module of the software (QCT Pro, Mindways) at each intervertebral disc level from T 12 /L 1 to L 5 /S 1 , as well as at the umbilical level. The total VAT volume was defined as the fat areas multiplied by the height of vertebral body for all six slices. Statistical analysis was performed to determine the correlation between single-slice VAT areas and the total VAT volume. Moreover, the optimal anatomic site for a single slice to estimate the total VAT volume was identified by multiple regression analysis. The cross-sectional area of VAT and subcutaneous adipose tissue (SAT) measured at each anatomic site was all highly correlated with the total VAT volume and the total SAT volume (r = 0.89-0.98). Additionally, the VAT area measured at the L 2 /L 3 level showed the strongest correlation with the total VAT volume (r = 0.98, P VAT volume. It is feasible to perform measurements of VAT area on a single slice at L 2 /L 3 level for estimating the total VAT volume.

  15. Focusing of white synchrotron radiation using large-acceptance cylindrical refractive lenses made of single – crystal diamond

    Energy Technology Data Exchange (ETDEWEB)

    Polikarpov, M., E-mail: polikarpov.maxim@mail.ru [Immanuel Kant Baltic Federal University, Nevskogo 14a, 23600 Kaliningrad (Russian Federation); Snigireva, I. [European Synchrotron Radiation Facility, 71 avenue des Martyrs, Grenoble 38043 (France); Snigirev, A. [Immanuel Kant Baltic Federal University, Nevskogo 14a, 23600 Kaliningrad (Russian Federation); European Synchrotron Radiation Facility, 71 avenue des Martyrs, Grenoble 38043 (France)

    2016-07-27

    Large-aperture cylindrical refractive lenses were manufactured by laser cutting of single-crystal diamond. Five linear single lenses with apertures of 1 mm and the depth of the structure of 1.2 mm were fabricated and tested at the ESRF ID06 beamline performing the focusing of white-beam synchrotron radiation. Uniform linear focus was stable during hours of exposure, representing such lenses as pre-focusing and collimating devices suitable for the front-end sections of today synchrotron radiation sources.

  16. Focusing of white synchrotron radiation using large-acceptance cylindrical refractive lenses made of single – crystal diamond

    International Nuclear Information System (INIS)

    Polikarpov, M.; Snigireva, I.; Snigirev, A.

    2016-01-01

    Large-aperture cylindrical refractive lenses were manufactured by laser cutting of single-crystal diamond. Five linear single lenses with apertures of 1 mm and the depth of the structure of 1.2 mm were fabricated and tested at the ESRF ID06 beamline performing the focusing of white-beam synchrotron radiation. Uniform linear focus was stable during hours of exposure, representing such lenses as pre-focusing and collimating devices suitable for the front-end sections of today synchrotron radiation sources.

  17. Comparison of high power large mode area and single mode 1908nm Tm-doped fiber lasers

    Science.gov (United States)

    Johnson, Benjamin R.; Creeden, Daniel; Limongelli, Julia; Pretorius, Herman; Blanchard, Jon; Setzler, Scott D.

    2016-03-01

    We compare large mode area (LMA) and single-mode (SM) double-clad fiber geometries for use in high power 1908nm fiber lasers. With a simple end-pumped architecture, we have generated 100W of 1908nm power with LMA fiber at 40% optical efficiency and 117W at 52.2% optical efficiency with single-mode fiber. We show the LMA fiber is capable of generating >200W and the SM fiber is capable of >300W at 1908nm. In all cases, the fiber lasers are monolithic power-oscillators with no free-space coupling.

  18. Design, Fabrication and Initial Testing of a Large Bore Single Aperture 1 m Long Superconducting Dipole Made with Phenolic Inserts

    CERN Document Server

    Boschmann, H; Kirby, G A; Lucas, J; Ostojic, R; Russenschuck, Stephan; Siemko, A; Vanenkov, I; Weterings, W

    1997-01-01

    In the framework of the LHC magnet development programme, a large bore single aperture 1-meter long superconducting dipole has been built in collaboration with HOLEC. The magnet features a single layer coil wound using the LHC main dipole outer layer cable, phenolic inserts, and a keyed two part structural iron yoke. This paper presents the magnetic and mechanical design and optimisation of the magnet. We describe the coil winding and curing, and present the construction and assembly procedures. Finally we report on the mechanical behaviour during assembly and cooling, and present the magnet training behaviour.

  19. Single-Seed Casting Large-Size Monocrystalline Silicon for High-Efficiency and Low-Cost Solar Cells

    Directory of Open Access Journals (Sweden)

    Bing Gao

    2015-09-01

    Full Text Available To grow high-quality and large-size monocrystal-line silicon at low cost, we proposed a single-seed casting technique. To realize this technique, two challenges—polycrystalline nucleation on the crucible wall and dislocation multiplication inside the crystal—needed to be addressed. Numerical analysis was used to develop solutions for these challenges. Based on an optimized furnace structure and operating conditions from numerical analysis, experiments were performed to grow monocrystalline silicon using the single-seed casting technique. The results revealed that this technique is highly superior to the popular high-performance multicrystalline and multiseed casting mono-like techniques.

  20. madSTORM: a superresolution technique for large-scale multiplexing at single-molecule accuracy

    Science.gov (United States)

    Yi, Jason; Manna, Asit; Barr, Valarie A.; Hong, Jennifer; Neuman, Keir C.; Samelson, Lawrence E.

    2016-01-01

    Investigation of heterogeneous cellular structures using single-molecule localization microscopy has been limited by poorly defined localization accuracy and inadequate multiplexing capacity. Using fluorescent nanodiamonds as fiducial markers, we define and achieve localization precision required for single-molecule accuracy in dSTORM images. Coupled with this advance, our new multiplexing strategy, madSTORM, allows accurate targeting of multiple molecules using sequential binding and elution of fluorescent antibodies. madSTORM is used on an activated T-cell to localize 25 epitopes, 14 of which are on components of the same multimolecular T-cell receptor complex. We obtain an average localization precision of 2.6 nm, alignment error of 2.0 nm, and molecules within structures. Probing the molecular topology of complex signaling cascades and other heterogeneous networks is feasible with madSTORM. PMID:27708141

  1. Not Only Enthalpy: Large Entropy Contribution to Ion Permeation Barriers in Single-File Channels

    OpenAIRE

    Portella, Guillem; Hub, Jochen S.; Vesper, Martin D.; de Groot, Bert L.

    2008-01-01

    The effect of channel length on the barrier for potassium ion permeation through single-file channels has been studied by means of all-atom molecular dynamics simulations. Using series of peptidic gramicidin-like and simplified ring-structured channels, both embedded in model membranes, we obtained two distinct types of behavior: saturation of the central free energy barriers for peptidic channels and a linear increase in simplified ring-structured channels with increasing channel length. The...

  2. SCANPY: large-scale single-cell gene expression data analysis.

    Science.gov (United States)

    Wolf, F Alexander; Angerer, Philipp; Theis, Fabian J

    2018-02-06

    SCANPY is a scalable toolkit for analyzing single-cell gene expression data. It includes methods for preprocessing, visualization, clustering, pseudotime and trajectory inference, differential expression testing, and simulation of gene regulatory networks. Its Python-based implementation efficiently deals with data sets of more than one million cells ( https://github.com/theislab/Scanpy ). Along with SCANPY, we present ANNDATA, a generic class for handling annotated data matrices ( https://github.com/theislab/anndata ).

  3. Telecommunication Wavelength-Band Single-Photon Emission from Single Large InAs Quantum Dots Nucleated on Low-Density Seed Quantum Dots.

    Science.gov (United States)

    Chen, Ze-Sheng; Ma, Ben; Shang, Xiang-Jun; He, Yu; Zhang, Li-Chun; Ni, Hai-Qiao; Wang, Jin-Liang; Niu, Zhi-Chuan

    2016-12-01

    Single-photon emission in the telecommunication wavelength band is realized with self-assembled strain-coupled bilayer InAs quantum dots (QDs) embedded in a planar microcavity on GaAs substrate. Low-density large QDs in the upper layer active for ~1.3 μm emission are fabricated by precisely controlling the indium deposition amount and applying a gradient indium flux in both QD layers. Time-resolved photoluminescence (PL) intensity suggested that the radiative lifetime of their exciton emission is 1.5~1.6 ns. The second-order correlation function of g (2)(0) < 0.5 which demonstrates a pure single-photon emission.

  4. Large bladder calculus masking a stone in single-system ureterocele.

    Science.gov (United States)

    Bhaskar, Ved; Sinha, Rahul Janak; Purkait, Bimalesh; Singh, Vishwajeet

    2017-06-14

    Ureterocele in an elderly is a rare entity. The presence of stone within ureterocele along with a large bladder calculus is an even rarer presentation. This phenomenon has not been reported so far to the best of our knowledge. We present an unusual case of a large bladder calculus with a concomitant stone in the associated ureterocele. The diagnosis was missed in the first instance due to the masking effect by the larger bladder calculus. Herein, we discuss this case and its management. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  5. Columbia University flow instability experimental program: Volume 6. Single annulus tests, transient test program

    Energy Technology Data Exchange (ETDEWEB)

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1992-09-01

    The coolant in the Savannah River Site (SRS) production nuclear reactor assemblies is circulated as a subcooled liquid under normal operating conditions. This coolant is evenly distributed throughout multiple annular flow channels with a uniform pressure profile across each coolant flow channel. During the postulated Loss of Coolant Accident (LOCA), which is initiated by a hypothetical guillotine pipe break, the coolant flow through the reactor assemblies is significantly reduced. The flow reduction and accompanying power reduction (after shutdown is initiated) occur in the first 1 to 2 seconds of the LOCA. This portion of the LOCA is referred to as the Flow Instability phase. This report presents the experimental results for the transient portion of the single annulus test program. The test program was designed to investigate the onset of flow instability in an annular geometry similar to the MARK 22 reactor. The test program involved testing of both a ribless heater and a ribbed heater under steady state as well as transient conditions. The ribbed heater testing is currently underway and will be reported separately. The steady state portion of this test program with ribless heater was completed and reported in report No. CU-HTRF-T3A. The present report presents transient test results obtained from a ribless, uniform annulus test section. A total of thirty five transients were conducted with six cases in which flow excursion occurred. No unstable conditions resulted for tests in which the steady state Q{sub ratio} OFI limit was not exceeded.

  6. Insights into the genome of large sulfur bacteria revealed by analysis of single filaments

    DEFF Research Database (Denmark)

    Mussmann, Marc; Hu, Fen Z.; Richter, Michael

    2007-01-01

    Marine sediments are frequently covered by mats of the filamentous Beggiatoa and other large nitrate-storing bacteria that oxidize hydrogen sulfide using either oxygen or nitrate, which they store in intracellular vacuoles. Despite their conspicuous metabolic properties and their biogeochemical...

  7. Single-grain Silicon Technology for Large Area X-ray Imaging

    NARCIS (Netherlands)

    Arslan, A.

    2015-01-01

    Digital flat panel X-ray imagers are currently using a-Si and poly-Si thin-film-transistors (TFTs). a-Si TFT permits the use of large area substrates, however, due to the amorphous nature, the carrier mobility is very low (<1 cm2/Vs). Poly-Si TFT improves the mobility (~150 cm2/Vs) but due to random

  8. Facile electrochemical transfer of large-area single crystal epitaxial graphene from Ir(1 1 1)

    DEFF Research Database (Denmark)

    Koefoed, Line; Kongsfelt, Mikkel; Ulstrup, Søren

    2015-01-01

    High-quality growth of graphene and subsequent reliable transfer to insulating substrates are needed for various technological applications, such as flexible screens and high speed electronics. In this paper, we present a new electrochemical method for the transfer of large-area, high-quality sin...

  9. Birt-Hogg-Dubé syndrome: a large single family cohort.

    Science.gov (United States)

    Skolnik, Kate; Tsai, Willis H; Dornan, Kimberly; Perrier, Renée; Burrowes, Paul W; Davidson, Warren J

    2016-02-29

    Birt-Hogg-Dubé (BHD) syndrome is an autosomal dominant condition characterized by dermatologic lesions, pulmonary manifestations, and renal tumors. The syndrome arises from germline mutations in the folliculin (FLCN) gene. We present findings from the single largest family BHD cohort described to date. Primary objectives were to characterize cystic lung changes on computed tomography (CT) chest scanning and identify features that stratify patients at higher risk of pneumothorax. Secondary objectives entailed description of the following: type and natural history of BHD-associated pneumothorax, pulmonary function characteristics, and relationship between cystic lung changes and pulmonary function. The study was a retrospective chart review for a case series of a single family. Over 70 family members of a proband with documented BHD were identified, 68 of which consented to genetic testing. All those with confirmed BHD were offered a clinical assessment by the Medical Genetics and Pulmonary services which included a history, physical exam, complete pulmonary function tests, and computed tomography (CT) scan of the chest and abdomen. Thirty-six individuals had a heterozygous mutation in the FLCN gene (c.59delT). Of these, 100 % (28/28) had pulmonary cysts, 41 % (13/32) had spontaneous pneumothoraces, 26 % (8/31) had kidney cysts, 3 % (1/31) had renal tumors, and 53 % (18/34) had dermatologic manifestations. Recurrent pneumothoraces were common (40 %). Cyst size (OR 3.23, 95 % CI 1.35-7.73) and extent of lower lung zone disease (OR 6.43, 95 % CI 1.41-29.2) were the only findings associated with pneumothorax. The size or extent of cystic disease did not correlate with lung function results. This is the largest single family cohort of patients with BHD syndrome documented to date. We found that all individuals had pulmonary cysts, pneumothoraces were common, and cyst size and lower lobe predominant disease were associated with pneumothorax. Lung function was generally

  10. The reaction of lithium metal vapor with single walled carbon nanotubes of large diameters

    Czech Academy of Sciences Publication Activity Database

    Kalbáč, Martin; Kavan, Ladislav; Dunsch, L.

    2009-01-01

    Roč. 246, 11-12 (2009), s. 2428-2431 ISSN 0370-1972 R&D Projects: GA AV ČR IAA400400911; GA AV ČR KAN200100801; GA AV ČR IAA400400804; GA ČR GC203/07/J067; GA MŠk LC510 Institutional research plan: CEZ:AV0Z40400503 Keywords : lithium * single walled carbon nanotubes * Raman spectroscopy Subject RIV: CG - Electrochemistry Impact factor: 1.150, year: 2009

  11. destiny: diffusion maps for large-scale single-cell data in R.

    Science.gov (United States)

    Angerer, Philipp; Haghverdi, Laleh; Büttner, Maren; Theis, Fabian J; Marr, Carsten; Buettner, Florian

    2016-04-15

    : Diffusion maps are a spectral method for non-linear dimension reduction and have recently been adapted for the visualization of single-cell expression data. Here we present destiny, an efficient R implementation of the diffusion map algorithm. Our package includes a single-cell specific noise model allowing for missing and censored values. In contrast to previous implementations, we further present an efficient nearest-neighbour approximation that allows for the processing of hundreds of thousands of cells and a functionality for projecting new data on existing diffusion maps. We exemplarily apply destiny to a recent time-resolved mass cytometry dataset of cellular reprogramming. destiny is an open-source R/Bioconductor package "bioconductor.org/packages/destiny" also available at www.helmholtz-muenchen.de/icb/destiny A detailed vignette describing functions and workflows is provided with the package. carsten.marr@helmholtz-muenchen.de or f.buettner@helmholtz-muenchen.de Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  12. Surface growth mechanisms and structural faulting in the growth of large single and spherulitic titanosilicate ETS-4 crystals

    Science.gov (United States)

    Miraglia, Peter Q.; Yilmaz, Bilge; Warzywoda, Juliusz; Sacco, Albert

    2004-10-01

    Morphological, surface and crystallographic analyses of titanosilicate ETS-4 products, with diverse habits ranging from spherulitic particles composed of submicron crystallites to large single crystals, are presented. Pole figures revealed that crystal surfaces with a-, b- and c- axes corresponded to , and directions, respectively. Thus, technologically important 8-membered ring pores and titania chains in ETS-4 run along the b-axis of single crystals and terminate at the smallest crystal face. Height of the spiral growth steps observed on {1 0 0} and {0 0 1} surfaces corresponded to the interplanar spacings associated with their crystallographic orientation, and is equivalent to the thickness of building units that form the ETS-4 framework. Data suggest that the more viscous synthesis mixtures, with a large driving force for growth, increased the two- and three-dimensional nucleation, while limiting the transport of nutrients to the growth surface. These conditions increase the tendency for stacking fault formation on {1 0 0} surfaces and small angle branching, which eventually results in spherulitic growth. The growth of high quality ETS-4 single crystals (from less viscous synthesis mixtures) occurred at lower surface nucleation rates. Data suggest that these high quality, large crystals grew due to one-dimensional nucleation at spiral hillocks, and indicate that under these conditions un-faulted growth is preferred.

  13. Can Effective Field Theory of inflation generate large tensor-to-scalar ratio within Randall–Sundrum single braneworld?

    International Nuclear Information System (INIS)

    Choudhury, Sayantan

    2015-01-01

    In this paper my prime objective is to explain the generation of large tensor-to-scalar ratio from the single field sub-Planckian inflationary paradigm within Randall–Sundrum (RS) single braneworld scenario in a model independent fashion. By explicit computation I have shown that the effective field theory prescription of brane inflation within RS single brane setup is consistent with sub-Planckian excursion of the inflaton field, which will further generate large value of tensor-to-scalar ratio, provided the energy density for inflaton degrees of freedom is high enough compared to the brane tension in high energy regime. Finally, I have mentioned the stringent theoretical constraint on positive brane tension, cut-off of the quantum gravity scale and bulk cosmological constant to get sub-Planckian field excursion along with large tensor-to-scalar ratio as recently observed by BICEP2 or at least generates the tensor-to-scalar ratio consistent with the upper bound of Planck (2013 and 2015) data and Planck+BICEP2+Keck Array joint constraint

  14. Extremely large and significantly anisotropic magnetoresistance in ZrSiS single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Lv, Yang-Yang; Zhang, Bin-Bin; Yao, Shu-Hua, E-mail: shyao@nju.edu.cn, E-mail: ybchen@nju.edu.cn, E-mail: zhoujian@nju.edu.cn; Zhou, Jian, E-mail: shyao@nju.edu.cn, E-mail: ybchen@nju.edu.cn, E-mail: zhoujian@nju.edu.cn; Zhang, Shan-Tao; Lu, Ming-Hui [National Laboratory of Solid State Microstructures and Department of Materials Science and Engineering, Nanjing University, Nanjing 210093 (China); Li, Xiao; Chen, Y. B., E-mail: shyao@nju.edu.cn, E-mail: ybchen@nju.edu.cn, E-mail: zhoujian@nju.edu.cn [National Laboratory of Solid State Microstructures and Department of Physics, Nanjing University, Nanjing 210093 (China); Chen, Yan-Feng [National Laboratory of Solid State Microstructures and Department of Materials Science and Engineering, Nanjing University, Nanjing 210093 (China); Collaborative Innovation Center of Advanced Microstructure, Nanjing University, Nanjing 210093 (China)

    2016-06-13

    Recently, the extremely large magnetoresistance (MR) observed in transition metal telluride, like WTe{sub 2}, attracted much attention because of the potential applications in magnetic sensor. Here, we report the observation of extremely large magnetoresistance as 3.0 × 10{sup 4}% measured at 2 K and 9 T magnetic field aligned along [001]-ZrSiS. The significant magnetoresistance change (∼1.4 × 10{sup 4}%) can be obtained when the magnetic field is titled from [001] to [011]-ZrSiS. These abnormal magnetoresistance behaviors in ZrSiS can be understood by electron-hole compensation and the open orbital of Fermi surface. Because of these superior MR properties, ZrSiS may be used in the magnetic sensors.

  15. The combination of octreotide and midodrine is not superior to albumin in preventing recurrence of ascites after large-volume paracentesis.

    Science.gov (United States)

    Bari, Khurram; Miñano, Cecilia; Shea, Martha; Inayat, Irteza B; Hashem, Hashem J; Gilles, Hochong; Heuman, Douglas; Garcia-Tsao, Guadalupe

    2012-10-01

    Large-volume paracentesis (LVP) is the treatment of choice for patients with cirrhosis and refractory ascites. However, LVP can lead to postparacentesis circulatory dysfunction (PCD), which is associated with faster ascites recurrence and renal failure. PCD results from vasodilatation, which reduces effective blood volume, and is prevented by intravenous administration of albumin. Vasoconstrictors could be used instead of albumin and, with longer use, prevent PCD and delay ascites recurrence. We performed a multicenter, randomized, double-blind, placebo-controlled trial to compare albumin with the vasoconstrictor combination of octreotide and midodrine in patients with refractory ascites who underwent LVP. Patients in the albumin group received a single intravenous dose of albumin at the time of LVP plus placebos for midodrine and octreotide (n = 13). Patients in the vasoconstrictor group received saline solution (as a placebo for albumin), 10 mg of oral midodrine (3 times/day), and a monthly 20-mg intramuscular injection of long-acting octreotide (n = 12). Patients were followed up until recurrence of ascites. The median times to recurrence of ascites were 10 days in the albumin group and 8 days in the vasoconstrictor group (P = .318). There were no significant differences in PCD between the albumin group (18%) and the vasoconstrictor group (25%, P = .574). When ascites recurred, serum levels of creatinine were higher in the vasoconstrictor group (1.2 vs 0.9 mg/dL in the albumin group; P = .051). The combination of midodrine and octreotide after LVP is not superior to albumin in delaying recurrence of ascites or preventing PCD in patients with cirrhosis. Outcomes appear to be worse in patients given octreotide and midodrine. ClinicalTrials.gov number, NCT00108355. Copyright © 2012 AGA Institute. Published by Elsevier Inc. All rights reserved.

  16. Large theoretical thermoelectric power factor of suspended single-layer MoS{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Babaei, Hasan, E-mail: babaei@illinois.edu, E-mail: babaei@auburn.edu [Mechanical Science and Engineering Department, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801-2906 (United States); Mechanical Engineering Department, Auburn University, Auburn, Alabama 36849-5341 (United States); Khodadadi, J. M. [Mechanical Engineering Department, Auburn University, Auburn, Alabama 36849-5341 (United States); Sinha, Sanjiv [Mechanical Science and Engineering Department, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801-2906 (United States)

    2014-11-10

    We have calculated the semi-classical thermoelectric power factor of suspended single-layer (SL)- MoS{sub 2} utilizing electron relaxation times derived from ab initio calculations. Measurements of the thermoelectric power factor of SL-MoS{sub 2} on substrates reveal poor power factors. In contrast, we find the thermoelectric power factor of suspended SL-MoS{sub 2} to peak at ∼2.8 × 10{sup 4} μW/m K{sup 2} at 300 K, at an electron concentration of 10{sup 12} cm{sup −2}. This figure is higher than that in bulk Bi{sub 2}Te{sub 3}, for example. Given its relatively high thermal conductivity, suspended SL-MoS{sub 2} may hold promise for in-plane thin-film Peltier coolers, provided reasonable mobilities can be realized.

  17. Twin interaction and large magnetoelasticity in Ni-Mn-Ga single crystals

    Science.gov (United States)

    Straka, L.; Hänninen, H.; Lanska, N.; Sozinov, A.

    2011-03-01

    We demonstrate experimentally the existence of triple twins in Ni-Mn-Ga magnetic shape memory single crystals with a modulated five-layered martensite structure using optical observations andx-ray diffraction. Subsequently, we investigate the response of the crystals with triple-twin segments to compressive loading up to several MPa. Such loading typically resulted in an abrupt rearrangement of the twin microstructure to a configuration with many fine twins (1-10 µm in size) ending at a twin boundary. This type of twin microstructure exhibited recoverable deformation with up to 0.3% macroscopic strain and an estimated 2.5% local strain, while the recoverable strain was much smaller for other studied microstructure configurations. The results indicate that by the creation of a suitable twin microstructure, the originally pseudoplastic or magnetoplastic material can be made rubberlike elastic or magnetoelastic with the macroscopic recoverable strain comparable to 2.5%.

  18. Large theoretical thermoelectric power factor of suspended single-layer MoS2

    International Nuclear Information System (INIS)

    Babaei, Hasan; Khodadadi, J. M.; Sinha, Sanjiv

    2014-01-01

    We have calculated the semi-classical thermoelectric power factor of suspended single-layer (SL)- MoS 2 utilizing electron relaxation times derived from ab initio calculations. Measurements of the thermoelectric power factor of SL-MoS 2 on substrates reveal poor power factors. In contrast, we find the thermoelectric power factor of suspended SL-MoS 2 to peak at ∼2.8 × 10 4 μW/m K 2 at 300 K, at an electron concentration of 10 12 cm −2 . This figure is higher than that in bulk Bi 2 Te 3 , for example. Given its relatively high thermal conductivity, suspended SL-MoS 2 may hold promise for in-plane thin-film Peltier coolers, provided reasonable mobilities can be realized

  19. Precoding Design for Single-RF Massive MIMO Systems: A Large System Analysis

    KAUST Repository

    Sifaou, Houssem

    2016-08-26

    This work revisits a recently proposed precoding design for massive multiple-input multiple output (MIMO) systems that is based on the use of an instantaneous total power constraint. The main advantages of this technique lie in its suitability to the recently proposed single radio frequency (RF) MIMO transmitter coupled with a very-high power efficiency. Such features have been proven using simulations for uncorrelated channels. Based on tools from random matrix theory, we propose in this work to analyze the performance of this precoder for more involved channels accounting for spatial correlation. The obtained expressions are then optimized in order to maximize the signalto- interference-plus-noise ratio (SINR). Simulation results are provided in order to illustrate the performance of the optimized precoder in terms of peak-to-average power ratio (PAPR) and signal-to-interference-plus-noise ratio (SINR). © 2012 IEEE.

  20. Application of ultradisperse magnetic adsorbents for removal of small concentrations of pollutants from large volumes of water

    Science.gov (United States)

    Nechitailo, Galina S.; Kuznetsov, Anatoli; Kuznetsov, Oleg

    2016-07-01

    Pollution of natural bodies of water (rivers, lakes, ground water, etc) is unfortunately very common, both from natural sources like volcanic activity; and, even more importantly, from human activity, including disposal of industrial and municipal waste, mining, etc. Many toxic substances are harmful for humans and other organisms even in very low concentrations (e.g., less than 1 µg/L of cadmium is harmful, for Hg it is 0.5 µg/L, for phenol - 1 µg/L), and can remain in water for decades or longer. Cleaning large volumes of water even from low concentrations of pollutants is a challenging technological task and is very expensive. We propose to use suspension of ultradisperse magnetic adsorbents, for example, nanostructured ferro-carbon particles, produced by plasmachemical technique, for removing small concentrations of pollutants from large volumes of water. The suspension is introduced into the water. Due to their small sizes and densities similar to water (we measured the density of FC-4 ferro-carbon to be about 1 g/cm3; presumably due to porosity) the particles do not sediment for a long time (hours, days or longer), move due to Brownian motion and adsorb a variety of substances from the water. The particle surface can be modified to provide selectivity of the adsorption. Sorption capacities of ferro-carbon adsorbents is in dozens of percent. Therefore, to collect 1 kg of a pollutant, 2 to 20 kg of the adsorbents is required. Then the particles with the adsorbed contaminant can be collected (e.g., downstream of the river) using a variety of magnetic traps. The traps can consist of ferromagnetic wires and permanent magnets, a variety of simple and inexpensive designs are available. As a model system, the kinetics of adsorption of a highly diluted (0.002 mg/ml) aqueous solution of a low molecular weight compound (toluidine blue) by a small concentration of a ferro-carbon powder (FC-4) was studied by spectrophotometry. Before each measurement, the particles

  1. Construction Method Study For Installation Of A Large Riser In A Single-Shell Tank

    International Nuclear Information System (INIS)

    Adkisson, D.A.

    2010-01-01

    This study evaluates and identifies a construction method for cutting a hole in a single-shell tank dome. This study also identifies and evaluates vendors for performing the cut. Single-shell tanks (SST) in the 241-C tank farm are currently being retrieved using various retrieval technologies (e.g., modified sluicing). The Hanford Federal Facility Agreement and Consent Order require that the SSTs be retrieved to less than 360 cubic feet of radioactive waste. The current technologies identified and deployed for tank retrieval have not been able to retrieve waste in accordance with the Hanford Federal Facility Agreement and Consent Order. As such, alternative retrieval systems have been proposed and are currently under construction that will have the ability to retrieve waste to this defined level. The proposed retrieval systems will not fit down existing risers. New risers will need to be installed to provide the retrieval systems access to the inside of the SSTs. The purpose of this study is two-fold. The first objective is to identify multiple concrete cutting technologies and perform an initial pre-screening, evaluate the technologies identified for more in-depth analysis, and recommend a technology/methodology for cutting a hole in the tank dome. The identified/pre-screened methods will be evaluated based on the following criteria: (1) Maturity/complexity; (2) Waste generation; (3) Safety; (4) Cost; and (5) Schedule. Once the preferred method is identified to cut the hole in the tank dome, the second objective is to identify, evaluate, and recommend a vendor for the technology selected that will perform the cutting process.

  2. A Comparative Study of Defibrillator Leads at a Large-Volume Implanting Hospital: Results From the Pacemaker and Implantable Defibrillator Leads Survival Study ("PAIDLESS").

    Science.gov (United States)

    Cohen, Todd J; Asheld, Wilbur J; Germano, Joseph; Islam, Shahidul; Patel, Dhimesh

    2015-06-01

    The purpose of the study was to examine survival in the implantable defibrillator subset of implanted leads at a large-volume implanting hospital. Implantable lead survival has been the subject of many multicenter studies over the past decade. Fewer large implanting volume single-hospital studies have examined defibrillator lead failure as it relates to patient survival and lead construction. This investigator-initiated retrospective study examined defibrillator lead failure in those who underwent implantation of a defibrillator between February 1, 1996 and December 31, 2011. Lead failure was defined as: failure to capture/sense, abnormal pacing and/or defibrillator impedance, visual insulation defect or lead fracture, extracardiac stimulation, cardiac perforation, tricuspid valve entrapment, lead tip fracture and/or lead dislodgment. Patient characteristics, implant approach, lead manufacturers, lead models, recalled status, patient mortality, and core lead design elements were compared using methods that include Kaplan Meier analysis, univariate and multivariable Cox regression models. A total of 4078 defibrillator leads were implanted in 3802 patients (74% male; n = 2812) with a mean age of 70 ± 13 years at Winthrop University Hospital. Lead manufacturers included: Medtronic: [n = 1834; 801 recalled]; St. Jude Medical: [n = 1707; 703 recalled]; Boston Scientific: [n = 537; 0 recalled]. Kaplan-Meier analysis adjusted for multiple comparisons revealed that both Boston Scientific's and St. Jude Medical's leads had better survival than Medtronic's leads (Pdefibrillation coil, and recalled lead status all contributed to lead failure. This study demonstrated a significantly improved lead performance in the Boston Scientific and St. Jude leads as compared with Medtronic leads. Some lead construction variables (insulation and number of coils) also had a significant impact on lead failure, which was independent of the manufacturer. Recalled St. Jude leads performed

  3. THE IMPORTANCE OF INFORMATION SYSTEMS IN THE MANAGEMENT AND PROCESSING OF LARGE DATA VOLUMES IN PUBLIC INSTITUTIONS

    Directory of Open Access Journals (Sweden)

    CARINA-ELENA STEGĂROIU

    2016-12-01

    Full Text Available Under a computerized society, technological resources become a source of identification for any community, institution or country. Globalization of information becomes a reality, all the resources having entered into a relationship of subordination with the World Wide Web, the information highways and the Internet. "Information technology - with its most important branch, data management computer science - enters a new era, in which the computer leads to the benefit of a navigable and transparent communication space, focusing on information". Therefore, in an information-based economy, information systems have been established which, based on management systems through the methods of algebra, with applications in economic engineering, have come to manage and process large volumes of data, especially in public institutions. Consequently, the Ministry of Public Affairs has implemented the “Increasing the public administration’s responsibility by modernising the information systems for generating the reports of the financial situations of public institutions” project (FOREXEBUG”, cod SMIS 34952, for which it received in 2012 non-refundable financing from the European Social Fund through the Operational Program for Developing the Administrative Capacity 2007-2013, based on which this paper will analyse the usefulness of implementing such a program in public institutions. Such a system aims to achieve a new form of reporting of budget execution and financial statements (including information related to legal commitments submitted monthly by each public institution in electronic, standardized, secure form, with increasing the reliability of data collected by cross-checking data from the treasury and providing reliable information for use by the Ministry of Finance, public institutions, other relevant institutions and the public, both at the level of detail and the consolidation possibilities at various levels, in parallel with their use for

  4. Childhood primary large vessel CNS vasculitis: single-centre experience and review of the literature.

    Science.gov (United States)

    Walsh, Sonja; Knöfler, Ralf; Hahn, Gabriele; Lohse, Judith; Berner, Reinhard; Brenner, Sebastian; Smitka, Martin; von der Hagen, Maja; Hedrich, Christian M

    2017-01-01

    Ischaemic brain injuries are rare conditions in the paediatric age group. Main causes include non-arteriosclerotic arteriopathies, which in childhood usually result from primary vasculitis of large or small vessels and lead to impaired perfusion and subsequent ischaemic brain lesions. In accordance with the nomenclature of systemic forms, CNS vasculitis is subdivided into groups, based on the size of affected vessels: angiography-positive primary angiitis of medium-sized and large vessels (pPACNS), and angiography-negative angiitis of small vessels (svPACNS). We report the clinical presentation, diagnostic approach, and therapy of four children with progressive pPACNS. Patients were treated with high-dose corticosteroids and anticoagulation with unfractionated heparin in the acute phase, followed by immune modulatory treatment with mycophenolate mofetil (MMF) and dual antiplatelet therapy with acetylsalicylic acid and clopidogrel. In this manuscript, we illustrate the experience gained in our hospital, resulting in significantly faster diagnosis and treatment initiation, and discuss the applied immune modulating treatment regimen in the context of the literature. Based on our observations, we conclude that immune modulating therapy with initial high-dose corticosteroids, followed by steroid-sparing maintenance treatment with MMF, may be safe and effective in childhood progressive pPACNS.

  5. The design and performance of a large-volume spherical CsI(Tl) scintillation counter for gamma-ray spectroscopy

    CERN Document Server

    Meng, L J; Chirkin, V M; Potapov, V N; Ivanov, O P; Ignatov, S M

    2002-01-01

    This paper presents details of the design and performance of a prototype large-volume scintillation detector used for gamma-ray spectroscopy. In this detector, a spherical CsI(Tl) scintillation crystal having a diameter of 5.7 cm was polished and packed in dry MgO powder. The scintillation light from the crystal was viewed using a single 1x1 cm sup 2 silicon PIN diode. A low-noise preamplifier was also integrated within the detector housing. The measured noise level was equivalent to approx 800 electrons (FWHM). Such a configuration provided a very good light collection efficiency, which resulted in an average of 20 electrons being generated per keV of energy deposited in the crystal. One of the key features of the detector design is that it minimises spatial variations in the light collection efficiency throughout the detector. Compared with a standard 3 in. NaI scintillation counter, this feature leads to a much-improved energy resolution, particularly for photon energies above 1 MeV. The results presented ...

  6. Large-size TlBr single crystal growth and defect study

    Science.gov (United States)

    Zhang, Mingzhi; Zheng, Zhiping; Chen, Zheng; Zhang, Sen; Luo, Wei; Fu, Qiuyun

    2018-04-01

    Thallium bromide (TlBr) is an attractive semiconductor material for fabrication of radiation detectors due to its high photon stopping power originating from its high atomic number, wide band gap and high resistivity. In this paper the vertical Bridgman method was used for crystal growth and TlBr single crystals with diameter of 15 mm were grown. X-ray diffraction (XRD) was used to identify phase and orientation. Electron backscatter diffraction (EBSD) was used to investigate crystal microstructure and crystallographic orientation. The optical and electric performance of the crystal was characterized by infrared (IR) transmittance spectra and I-V measurement. The types of point defects in the crystals were investigated by thermally stimulated current (TSC) spectra and positron annihilation spectroscopy (PAS). Four types of defects, with ionization energy of each defect fitting as follows: 0.1308, 0.1540, 0.3822 and 0.538 eV, were confirmed from the TSC result. The PAS result showed that there were Tl vacancies in the crystal.

  7. Toward an Improved Single-Particle Model for Large Irregular Grains

    Science.gov (United States)

    Grundy, W. M.; Schmitt, B.; Doute, S.

    2002-01-01

    To interpret remote spectral observations, scattering and absorption in a particulate surface are simulated via radiative transfer models. The standard model for this purpose among the planetary science community is the Hapke model. This model (like many others) uses two parameters to characterize the optical behavior of individual grains in a particulate surface, the single-scattering albedo omega and phase function p(g). These terms describe, respectively, the quantity and the angular distribution of light scattered by an individual grain. Unfortunately, these parameters are strictly optical. They can be rather difficult to interpret in terms of more interesting particle properties such as grain sizes, shapes, and compositions, that a remote sensing experiment might seek to discover. An equivalent slab approximation is typically used to relate omega to the grain size and optical constants of the material. This approach can mimic the wavelength-dependent absorption behavior of irregular grains, as long as the imaginary index kappa is much less than 1, the shape is equant, and the grain size D is much larger than the wavelength lambda. Unfortunately, the equivalent slab approach provides no information about p(g), which also has a strong dependence on optical constants and particle form.

  8. Large-scale separation of single-walled carbon nanotubes by electronic type using click chemistry

    Science.gov (United States)

    Um, Jo-Eun; Song, Sun Gu; Yoo, Pil J.; Song, Changsik; Kim, Woo-Jae

    2018-01-01

    Single-walled carbon nanotubes (SWCNTs) can be either metallic or semiconducting, making their separation critical for applications in nanoelectronics, biomedical materials, and solar cells. Herein, we investigate a novel solution-phase separation method based on click chemistry (azide-alkyne Huisgen cycloaddition) and determine its efficiency and scalability. In this method, metallic SWCNTs in metallic/semiconducting SWCNT mixtures are selectively functionalized with alkyne groups by being reacted with 4-propargyloxybenezenediazonium tetrafluoroborate. Subsequently, silica nanoparticles are functionalized with azide groups and reacted with alkyne-bearing metallic SWCNTs in the SWCNT mixture in the presence of a Cu catalyst. As a result, metallic SWCNTs are anchored on silica powder, whereas non-functionalized semiconducting SWCNTs remain in solution. Low-speed centrifugation effectively removes the silica powder with attached metallic SWCNTs, furnishing a solution of highly pure semiconducting SWCNTs, as confirmed by Raman and UV-vis/near-infrared absorption measurements. This novel separation scheme exhibits the advantage of simultaneously separating both metallic and semiconducting SWCNTs from their mixtures, being cost-effective and therefore applicable at an industrial scale.

  9. Large work function difference driven electron transfer from electrides to single-walled carbon nanotubes

    KAUST Repository

    Menamparambath, Mini Mol

    2014-06-23

    A difference in work function plays a key role in charge transfer between two materials. Inorganic electrides provide a unique opportunity for electron transfer since interstitial anionic electrons result in a very low work function of 2.4-2.6 eV. Here we investigated charge transfer between two different types of electrides, [Ca2N]+·e- and [Ca 24Al28O64]4+·4e-, and single-walled carbon nanotubes (SWNTs) with a work function of 4.73-5.05 eV. [Ca2N]+·e- with open 2-dimensional electron layers was more effective in donating electrons to SWNTs than closed cage structured [Ca24Al28O64] 4+·4e- due to the higher electron concentration (1.3 × 1022 cm-3) and mobility (∼200 cm 2 V-1 s-1 at RT). A non-covalent conjugation enhanced near-infrared fluorescence of SWNTs as high as 52%. The field emission current density of electride-SWNT-silver paste dramatically increased by a factor of 46000 (14.8 mA cm-2) at 2 V μm-1 (3.5 wt% [Ca2N]+·e-) with a turn-on voltage of 0.85 V μm-1. This journal is © the Partner Organisations 2014.

  10. Single-Molecule Analysis of Protein Large-Amplitude Conformational Transitions

    Science.gov (United States)

    Yang, Haw

    2011-03-01

    Proteins have evolved to harness thermal fluctuations, rather than frustrated by them, to carry out chemical transformations and mechanical work. What are, then, the operation and design principles of protein machines? To frame the problem in a tractable way, several basic questions have been formulated to guide the experimental design: (a) How many conformational states can a protein sample on the functionally important timescale? (b) What are the inter-conversion rates between states? (c) How do ligand binding or interactions with other proteins modulate the motions? (d) What are the structural basis of flexibility and its underlying molecular mechanics? Guided by this framework, we have studied protein tyrosine phosphatase B, PtpB, from M. tuberculosis (a virulence factor of tuberculosis and a potential drug target) and adenylate kinase, AK, from E. coli (a ubiquitous energy-balancing enzyme in cells). These domain movements have been followed in real time on their respective catalytic timescales using high-resolution single-molecule Förster resonance energy transfer (FRET) spectroscopy. It is shown quantitatively that both PtpB and AK are capable of dynamically sampling two distinct states that correlate well with those observed by x-ray crystallography. Integrating these microscopic dynamics into macroscopic kinetics allows us to place the experimentally measured free-energy landscape in the context of enzymatic turnovers.

  11. Large-Scale Procurement of Radiation Resistant Single-Mode Optical Fibers for CERN

    CERN Document Server

    Guillermain, Elisa; Kuhnhenn, Jochen; Ricci, Daniel; Weinand, Udo

    2015-01-01

    2400 km of special radiation resistant optical fibres were procured by CERN (European Organization for Nuclear Research), for the installation of more than 55 km of optical fibre cables in the accelerator complex underground during the Long Shutdown 1 (LS1). In the frame of this large-scale industrial production, a thorough quality assurance plan (QAP) was put in place and followed at each step of the process. In-depth qualification of optical fibres preceded the 17-month procurement process. All supplied batches were tested for their resistance to radiation, leading to more than 65 quality control irradiation tests. During the cable assembly process and the installations works, a full traceability down to the optical fibre level was ensured. The actions put in place in the frame of the QAP led to successful installation works and to full respect of the LS1 planning.

  12. Single-field consistency relations of large scale structure part III: test of the equivalence principle

    Energy Technology Data Exchange (ETDEWEB)

    Creminelli, Paolo [Abdus Salam International Centre for Theoretical Physics, Strada Costiera 11, Trieste, 34151 (Italy); Gleyzes, Jérôme; Vernizzi, Filippo [CEA, Institut de Physique Théorique, Gif-sur-Yvette cédex, F-91191 France (France); Hui, Lam [Physics Department and Institute for Strings, Cosmology and Astroparticle Physics, Columbia University, New York, NY, 10027 (United States); Simonović, Marko, E-mail: creminel@ictp.it, E-mail: jerome.gleyzes@cea.fr, E-mail: lhui@astro.columbia.edu, E-mail: msimonov@sissa.it, E-mail: filippo.vernizzi@cea.fr [SISSA, via Bonomea 265, Trieste, 34136 (Italy)

    2014-06-01

    The recently derived consistency relations for Large Scale Structure do not hold if the Equivalence Principle (EP) is violated. We show it explicitly in a toy model with two fluids, one of which is coupled to a fifth force. We explore the constraints that galaxy surveys can set on EP violation looking at the squeezed limit of the 3-point function involving two populations of objects. We find that one can explore EP violations of order 10{sup −3}÷10{sup −4} on cosmological scales. Chameleon models are already very constrained by the requirement of screening within the Solar System and only a very tiny region of the parameter space can be explored with this method. We show that no violation of the consistency relations is expected in Galileon models.

  13. Growth of large single-crystalline two-dimensional boron nitride hexagons on electropolished copper.

    Science.gov (United States)

    Tay, Roland Yingjie; Griep, Mark H; Mallick, Govind; Tsang, Siu Hon; Singh, Ram Sevak; Tumlin, Travis; Teo, Edwin Hang Tong; Karna, Shashi P

    2014-02-12

    Hexagonal-boron nitride (h-BN) or "white graphene" has many outstanding properties including high thermal conductivity, high mechanical strength, chemical inertness, and high electrical resistance, which open up a wide range of applications such as thermal interface material, protective coatings, and dielectric in nanoelectronics that easily exceed the current advertised benefits pertaining to the graphene-based applications. The development of h-BN films using chemical vapor deposition (CVD) has thus far led into nucleation of triangular or asymmetric diamond shapes on different metallic surfaces. Additionally, the average size of the triangular domains has remained relatively small (∼ 0.5 μm(2)) leading to a large number of grain boundaries and defects. While the morphology of Cu surfaces for CVD-grown graphene may have impacts on the nucleation density, domain sizes, thickness, and uniformity, the effects of the decreased roughness of Cu surface to develop h-BN films are unknown. Here, we report the growth and characterization of novel large area h-BN hexagons using highly electropolished Cu substrate under atmospheric pressure CVD conditions. We found that the nucleation density of h-BN is significantly reduced while domain sizes increase. In this study, the largest hexagonal-shape h-BN domain observed is 35 μm(2), which is an order of magnitude larger than a typical triangular domain. As the domains coalesce to form a continuous film, the larger grain size offers a more pristine and smoother film with lesser grain boundaries induced defects.

  14. Centrifugal multiplexing fixed-volume dispenser on a plastic lab-on-a-disk for parallel biochemical single-end-point assays.

    Science.gov (United States)

    La, Moonwoo; Park, Sang Min; Kim, Dong Sung

    2015-01-01

    In this study, a multiple sample dispenser for precisely metered fixed volumes was successfully designed, fabricated, and fully characterized on a plastic centrifugal lab-on-a-disk (LOD) for parallel biochemical single-end-point assays. The dispenser, namely, a centrifugal multiplexing fixed-volume dispenser (C-MUFID) was designed with microfluidic structures based on the theoretical modeling about a centrifugal circumferential filling flow. The designed LODs were fabricated with a polystyrene substrate through micromachining and they were thermally bonded with a flat substrate. Furthermore, six parallel metering and dispensing assays were conducted at the same fixed-volume (1.27 μl) with a relative variation of ±0.02 μl. Moreover, the samples were metered and dispensed at different sub-volumes. To visualize the metering and dispensing performances, the C-MUFID was integrated with a serpentine micromixer during parallel centrifugal mixing tests. Parallel biochemical single-end-point assays were successfully conducted on the developed LOD using a standard serum with albumin, glucose, and total protein reagents. The developed LOD could be widely applied to various biochemical single-end-point assays which require different volume ratios of the sample and reagent by controlling the design of the C-MUFID. The proposed LOD is feasible for point-of-care diagnostics because of its mass-producible structures, reliable metering/dispensing performance, and parallel biochemical single-end-point assays, which can identify numerous biochemical.

  15. Study of n-γ discrimination by digital charge comparison method for a large volume liquid scintillator

    International Nuclear Information System (INIS)

    Moszynski, M.; Costa, G.J.; Guillaume, G.; Heusch, B.; Huck, A.; Ring, C.; Bizard, G.; Durand, D.; Peter, J.; Tamain, B.; El Masri, Y.; Hanappe, F.

    1992-01-01

    The study of the n-γ discrimination for a large 41 volume BC501A liquid scintillator coupled to a 130 mm diameter XP4512B photomultiplier was carried out by digital charge comparison method. A very good n-γ discrimination down to 100 keV of recoil electron energy was achieved. The measured relative intensity of the charge integrated at the slow component of the scintillation pulse and the photoelectron yield of the tested counter allow the factor of merit of the n-γ discrimination spectra to be calculated and to be compared with those measured experimentally. This shows that the main limitation of the n-γ discrimination is associated with the statistical fluctuation of the photoelectron number at the slow component. A serious effect of the distortion in the cable used to send the photomultiplier pulse to the electronics for the n-γ discrimination was studied. This suggests that the length of RG58 cable should be limited to about 40 m to preserve a high quality n-γ discrimination. (orig.)

  16. APS 6BM-B Large Volume High Pressure Beamline: A Workhorse for Rock and Mineral Physics

    Science.gov (United States)

    Chen, H.; Whitaker, M. L.; Baldwin, K. J.; Huebsch, W. R.; Vaughan, M. T.; Weidner, D. J.

    2017-12-01

    With the inheritance of decades of technical innovations at the NSLS X17B2 Beamline, APS 6BM-B Beamline was established in 2015 and is a dedicated beamline for synchrotron-based large volume high pressure research in earth sciences, especially rock and mineral physics. Currently a 250-ton hydraulic press equipped with a D-DIA module is installed and a Rotational Drickamer Apparatus from Yale University is hosted every cycle, covering a pressure range from crust to lower mantle. 6BM-B operates in white beam mode with an effective energy range of 20-100 keV. Energy dispersive X-ray diffraction data is collected using a 10-element solid state Ge array detector arranged in a circular geometry to allow for the real time assessment of stress. Direct radiographic imaging using Prosillica CCD camera and scintillating YAG crystals yields sample strain and strain rate. In addition to applications in phase transitions, equation of states measurements, sound velocity measurements, this setup is ideal for studies of steady state and dynamic deformation process. In this presentation, technical features and strengths of 6BM-B will be discussed. Most recent progress and science highlights of our user community will be showcased.

  17. Multiplex, quantitative cellular analysis in large tissue volumes with clearing-enhanced 3D microscopy (Ce3D).

    Science.gov (United States)

    Li, Weizhe; Germain, Ronald N; Gerner, Michael Y

    2017-08-29

    Organ homeostasis, cellular differentiation, signal relay, and in situ function all depend on the spatial organization of cells in complex tissues. For this reason, comprehensive, high-resolution mapping of cell positioning, phenotypic identity, and functional state in the context of macroscale tissue structure is critical to a deeper understanding of diverse biological processes. Here we report an easy to use method, clearing-enhanced 3D (C e 3D), which generates excellent tissue transparency for most organs, preserves cellular morphology and protein fluorescence, and is robustly compatible with antibody-based immunolabeling. This enhanced signal quality and capacity for extensive probe multiplexing permits quantitative analysis of distinct, highly intermixed cell populations in intact C e 3D-treated tissues via 3D histo-cytometry. We use this technology to demonstrate large-volume, high-resolution microscopy of diverse cell types in lymphoid and nonlymphoid organs, as well as to perform quantitative analysis of the composition and tissue distribution of multiple cell populations in lymphoid tissues. Combined with histo-cytometry, C e 3D provides a comprehensive strategy for volumetric quantitative imaging and analysis that bridges the gap between conventional section imaging and disassociation-based techniques.

  18. A large volume double channel 1H-X RF probe for hyperpolarized magnetic resonance at 0.0475 T

    Science.gov (United States)

    Coffey, Aaron M.; Shchepin, Roman V.; Wilkens, Ken; Waddell, Kevin W.; Chekmenev, Eduard Y.

    2012-07-01

    In this work we describe a large volume 340 mL 1H-X magnetic resonance (MR) probe for studies of hyperpolarized compounds at 0.0475 T. 1H/13C and 1H/15N probe configurations are demonstrated with the potential for extension to 1H/129Xe. The primary applications of this probe are preparation and quality assurance of 13C and 15N hyperpolarized contrast agents using PASADENA (parahydrogen and synthesis allow dramatically enhanced nuclear alignment) and other parahydrogen-based methods of hyperpolarization. The probe is efficient and permits 62 μs 13C excitation pulses at 5.3 W, making it suitable for portable operation. The sensitivity and detection limits of this probe, tuned to 13C, are compared with a commercial radio frequency (RF) coil operating at 4.7 T. We demonstrate that low field MR of hyperpolarized contrast agents could be as sensitive as conventional high field detection and outline potential improvements and optimization of the probe design for preclinical in vivo MRI. PASADENA application of this low-power probe is exemplified with 13C hyperpolarized 2-hydroxyethyl propionate-1-13C,2,3,3-d3.

  19. Solid-Phase Extraction and Large-Volume Sample Stacking-Capillary Electrophoresis for Determination of Tetracycline Residues in Milk

    Directory of Open Access Journals (Sweden)

    Gabriela Islas

    2018-01-01

    Full Text Available Solid-phase extraction in combination with large-volume sample stacking-capillary electrophoresis (SPE-LVSS-CE was applied to measure chlortetracycline, doxycycline, oxytetracycline, and tetracycline in milk samples. Under optimal conditions, the proposed method had a linear range of 29 to 200 µg·L−1, with limits of detection ranging from 18.6 to 23.8 µg·L−1 with inter- and intraday repeatabilities < 10% (as a relative standard deviation in all cases. The enrichment factors obtained were from 50.33 to 70.85 for all the TCs compared with a conventional capillary zone electrophoresis (CZE. This method is adequate to analyze tetracyclines below the most restrictive established maximum residue limits. The proposed method was employed in the analysis of 15 milk samples from different brands. Two of the tested samples were positive for the presence of oxytetracycline with concentrations of 95 and 126 µg·L−1. SPE-LVSS-CE is a robust, easy, and efficient strategy for online preconcentration of tetracycline residues in complex matrices.

  20. Cumulative recruitment experience in two large single-center randomized, controlled clinical trials.

    Science.gov (United States)

    Galbreath, Autumn Dawn; Smith, Brad; Wood, Pamela; Forkner, Emma; Peters, Jay I

    2008-05-01

    Trial recruitment is challenging for researchers, who frequently overestimate the pool of qualified, willing participants. Little has been written about recruitment and the comparative success of recruitment strategies. We describe one center's experience with recruitment in two regional single-center clinical trials with a combined total of 1971 participants. The heart failure trial was conducted between 1999 and 2003. The asthma trial was performed between 2003 and 2006. Trial databases were queried for referral source of each individual. Data were analyzed for effectiveness of referral source using three measures: percentage of enrollment due to that source, subject commitment to the trial (retention rate), and economics (cost per enrollee). 47.8% of CHF enrollees came from computer-generated lists or from healthcare provider referrals. Average marketing cost for enrollees and completers was $29.20 and $41.96 respectively. The most economical marketing strategy was self-referral in response to flyers. Most asthma participants (53.5%) were referred from healthcare providers, mailings to lists from local healthcare institutions, or self-referred in response to flyers. Average marketing cost for enrollees and completers was $20.44 and $38.10 respectively. The most economical marketing strategy was patient mailings. Retention rates were not markedly different among referral sources in either trial. In order to be considered effective, a recruitment strategy must demonstrate a balance between response to recruitment, retention rates, and economics. Despite the differences between these two clinical trials, the most effective recruitment strategies in both trials were mailings to locally-generated, targeted lists, and referrals from healthcare providers.

  1. Can the single-breath helium dilution method predict lung volumes as measured by whole-body plethysmography?

    Directory of Open Access Journals (Sweden)

    Patrícia Chaves Coertjens

    2013-12-01

    Full Text Available OBJECTIVE: To compare TLC and RV values obtained by the single-breath helium dilution (SBHD method with those obtained by whole-body plethysmography (WBP in patients with normal lung function, patients with obstructive lung disease (OLD, and patients with restrictive lung disease (RLD, varying in severity, and to devise equations to estimate the SBHD results.METHODS: This was a retrospective cross-sectional study involving 169 individuals, of whom 93 and 49 presented with OLD and RLD, respectively, the remaining 27 having normal lung function. All patients underwent spirometry and lung volume measurement by both methods.RESULTS: TLC and RV were higher by WBP than by SBHD. The discrepancy between the methods was more pronounced in the OLD group, correlating with the severity of airflow obstruction. In the OLD group, the correlation coefficient of the comparison between the two methods was 0.57 and 0.56 for TLC and RV, respectively (p < 0.001 for both. We used regression equations, adjusted for the groups studied, in order to predict the WBP values of TLC and RV, using the corresponding SBHD values. It was possible to create regression equations to predict differences in TLC and RV between the two methods only for the OLD group. The TLC and RV equations were, respectively, ∆TLCWBP-SBHD in L = 5.264 − 0.060 × FEV1/FVC (r2= 0.33; adjusted r2 = 0.32 and ∆RVWBP-SBHD in L = 4.862 − 0.055 × FEV1/FVC (r2= 0.31; adjusted r2 = 0.30.CONCLUSIONS: The correction of TLC and RV results obtained by SBHD can improve the accuracy of this method for assessing lung volumes in patients with OLD. However, additional studies are needed in order to validate these equations.

  2. Large-sub(pT) production of single and double photons in proton-proton and pion-proton collisions

    International Nuclear Information System (INIS)

    Berger, E.L.; Argonne National Lab., IL; Braaten, E.; Field, R.D.

    1984-01-01

    Quantum chromodynamic (QCD) predictions are made for the large transverse momentum production of single and double photons in proton-proton, proton-antiproton, and pion-proton collisions. In π - p collisions at center-of-mass energy W=27.4 GeV and psub(T)=4.0 GeV, it is estimated that about 0.3% of the 90 0 single photon triggers will be balanced on the 'away-side' by a single photon with roughly the same transverse momentum. In π + p collisions this fraction drops to about 0.09%. These fractions increase with psub(T). In addition to the pure QED annihilation term qanti q -> γγ, it is found that the QCD-induced subprocess gg -> γγ provides an important source of double photons. Photon bremsstrahlung contributions are also examined. Experimental study of the systematics of single and double photon production in hadron-hadron collisions will provide information on the size of the strong interaction coupling constant, αsub(s)(Q), and on the charges of the quarks. Knowledge of the gluon distributions within hadrons and of the effective transverse momentum of partons in hadrons can also be gained. (orig.)

  3. Large Conization and Laparoendoscopic Single-Port Pelvic Lymphadenectomy in Early-Stage Cervical Cancer for Fertility Preservation

    Directory of Open Access Journals (Sweden)

    Polat Dursun

    2013-01-01

    Full Text Available Fertility preservation in early-stage cervical cancer is a hot topic in gynecologic oncology. Although radical vaginal trachelectomy (RVT is suggested as a fertility preserving approach, there are some serious concerns like cervical stenosis, second trimester loss, preterm delivery in survivors, and lack of residual tumor in the majority of the surgical specimens. Therefore, less radical surgical operations have been proposed in early-stage cervical carcinomas. On the other hand, single-incision laparoscopic surgery (SILS is an evolving endoscopic approach for minimal access surgery. In this report, we present a case with early-stage cervical cancer who wishes to preserve fertility. We successfully performed single-port pelvic lymphadenectomy and large conization to preserve fertility potential of the patient. We think that combination of less radical approach like conization and single-port pelvic lymphadenectomy might be less minimally invasive and is still an effective surgical approach in well-selected cases with cervical carcinomas. Incorporation of single-port laparoscopy into the minimally invasive fertility sparing management of the cervical cancer will improve patients outcome with less complications and better cosmesis. Further studies are needed to reach a clear conclusion.

  4. Spontaneous Neuronal Activity in Developing Neocortical Networks: From Single Cells to Large-Scale Interactions.

    Science.gov (United States)

    Luhmann, Heiko J; Sinning, Anne; Yang, Jenq-Wei; Reyes-Puerta, Vicente; Stüttgen, Maik C; Kirischuk, Sergei; Kilb, Werner

    2016-01-01

    Neuronal activity has been shown to be essential for the proper formation of neuronal circuits, affecting developmental processes like neurogenesis, migration, programmed cell death, cellular differentiation, formation of local and long-range axonal connections, synaptic plasticity or myelination. Accordingly, neocortical areas reveal distinct spontaneous and sensory-driven neuronal activity patterns already at early phases of development. At embryonic stages, when immature neurons start to develop voltage-dependent channels, spontaneous activity is highly synchronized within small neuronal networks and governed by electrical synaptic transmission. Subsequently, spontaneous activity patterns become more complex, involve larger networks and propagate over several neocortical areas. The developmental shift from local to large-scale network activity is accompanied by a gradual shift from electrical to chemical synaptic transmission with an initial excitatory action of chloride-gated channels activated by GABA, glycine and taurine. Transient neuronal populations in the subplate (SP) support temporary circuits that play an important role in tuning early neocortical activity and the formation of mature neuronal networks. Thus, early spontaneous activity patterns control the formation of developing networks in sensory cortices, and disturbances of these activity patterns may lead to long-lasting neuronal deficits.

  5. Large Anisotropy Barrier in a Tetranuclear Single-Molecule Magnet Featuring Low-Coordinate Cobalt Centers.

    Science.gov (United States)

    Chakarawet, Khetpakorn; Bunting, Philip C; Long, Jeffrey R

    2018-02-14

    The tetranuclear cobalt cluster compound [Co 4 (μ-NP t Bu 3 ) 4 ][B(C 6 F 5 ) 4 ] ( t Bu = tert-butyl) was synthesized by chemical oxidation of Co 4 (NP t Bu 3 ) 4 with [FeCp 2 ][B(C 6 F 5 ) 4 ] and magnetically characterized to study the effect of electronic communication between low-coordinate metal centers on slow magnetic relaxation in a transition metal cluster. The dc magnetic susceptibility data reveal that the complex exhibits a well-isolated S = 9 / 2 ground state, which persists even to 300 K and is attributed to the existence of direct metal-metal orbital overlap. The ac magnetic susceptibility data further reveals that the complex exhibits slow magnetic relaxation in the absence of an applied field, and that the relaxation dynamics can be fit with a combination of Orbach, quantum tunneling, and Raman relaxation processes. The effective spin reversal barrier for this molecule is 87 cm -1 , the largest reported to date for a transition metal cluster, and arises due to the presence of a large easy-axis magnetic anisotropy. The complex additionally exhibits waist-restricted magnetic hysteresis and magnetic blocking below 3.6 K. Taken together, these results indicate that coupling of low-coordinate metal centers is a promising strategy to enhance magnetic anisotropy and slow magnetic relaxation in transition metal cluster compounds.

  6. Large vestibular schwannomas and hydrocephalus: Lessons learnt from a single centre experience

    Directory of Open Access Journals (Sweden)

    Prakash Nair

    2014-01-01

    Full Text Available Aim: The aim of the following study is to analyze the outcome following surgery in 169 patients with large vestibular schwannoma (VS and to evaluate hydrocephalus as a prognostic factor in patients of the VSs. Subjects and Methods: Retrospective analysis of all cases of VSs admitted to our tertiary neurosurgical center from January 2005 to December 2010 was performed. Comparison of patients who underwent pre-operative cerebrospinal fluid (CSF diversion and those who underwent primary surgery was carried out for post-operative complications and delayed hydrocephalus. Results: A total of 169 patients of VS were seen. The mean age at presentation was 39.03 years (12-72 years. The most common symptom was hearing loss seen in 161 (95.2% cases. Giant VS was seen in 130 (75.5% and hydrocephalus was present in 110 (63.9%. Pre-operative CSF diversion was done in 23 (13.1% patients; 8 (4.6% patients developed gradually symptomatic hydrocephalus following surgery and underwent ventriculoperitoneal shunt. Total surgical excision was done in 92.9% patients and subtotal excision was done in 7% patients. Conclusions: Hydrocephalus occurs in longstanding untreated cases of VS. Hydrocephalus causes no statistically significant increase in post-operative complications like CSF leak and post-operative hematoma. Patients with hydrocephalus presenting with acute symptoms of raised intracranial pressure benefit from CSF diversion. In most patients, tumor resection will restore patency of the CSF pathway and CSF diversion can be avoided.

  7. Growth of large size lithium niobate single crystals of high quality by tilting-mirror-type floating zone method

    Energy Technology Data Exchange (ETDEWEB)

    Sarker, Abdur Razzaque, E-mail: razzaque_ru2000@yahoo.com [Department of Physics, University of Rajshahi (Bangladesh)

    2016-05-15

    Large size high quality LiNbO{sub 3} single crystals were grown successfully by tilting-mirror-type floating zone (TMFZ) technique. The grown crystals were characterized by X-ray diffraction, etch pits density measurement, Impedance analysis, Vibrating sample magnetometry (VSM) and UV-Visible spectrometry. The effect of mirror tilting during growth on the structural, electrical, optical properties and defect density of the LiNbO{sub 3} crystals were investigated. It was found that the defect density in the crystals reduced for tilting the mirror in the TMFZ method. The chemical analysis revealed that the grown crystals were of high quality with uniform composition. The single crystals grown by TMFZ method contains no low-angle grain boundaries, indicating that they can be used for high efficiency optoelectronic devices. (author)

  8. Successful Large-volume Leukapheresis for Hematopoietic Stem Cell Collection in a Very-low-weight Brain Tumor Infant with Coagulopathy

    Directory of Open Access Journals (Sweden)

    Yu-Mei Liao

    2013-06-01

    Full Text Available Peripheral apheresis has become a safe procedure to collect hematopoietic stem cells, even in pediatric patients and donors. However, the apheresis procedure for small and sick children is more complicated due to difficult venous access, relatively large extracorporeal volume, toxicity of citrate, and unstable hemostasis. We report a small and sick child with refractory medulloblastoma, impaired liver function, and coagulopathy after several major cycles of cisplatin-based chemotherapy. She successfully received large-volume leukapheresis for hematopoietic stem cell collection, although the patient experienced severe coagulopathy during the procedures. Health care providers should be alert to this potential risk.

  9. A large-volume press facility at the Advanced Photon Source: diffraction and imaging studies on materials relevant to the cores of planetary bodies

    CERN Document Server

    Uchida, T; Rivers, M L; Sutton, S R; Weidner, D J; Vaughan, M T; Chen, J; Li, B; Secco, R A; Rutter, M D; Liu, H

    2002-01-01

    A new large-volume, high-pressure facility is being utilized and developed as part of GeoSoilEnviroCARS at a third-generation synchrotron, the Advanced Photon Source. This user facility consists of two large-volume presses (LVP), a 2.5 MN (250 ton) LVP installed at the bending magnet beamline, and a 10 MN (1000 ton) LVP at the insertion device beamline. Here we report some techniques currently being developed with the 10 MN LVP and the latest scientific results obtained using the 2.5 MN LVP.

  10. Observing the Sun with the Atacama Large Millimeter/submillimeter Array (ALMA): Fast-Scan Single-Dish Mapping

    Science.gov (United States)

    White, S. M.; Iwai, K.; Phillips, N. M.; Hills, R. E.; Hirota, A.; Yagoubov, P.; Siringo, G.; Shimojo, M.; Bastian, T. S.; Hales, A. S.; Sawada, T.; Asayama, S.; Sugimoto, M.; Marson, R. G.; Kawasaki, W.; Muller, E.; Nakazato, T.; Sugimoto, K.; Brajša, R.; Skokić, I.; Bárta, M.; Kim, S.; Remijan, A. J.; de Gregorio, I.; Corder, S. A.; Hudson, H. S.; Loukitcheva, M.; Chen, B.; De Pontieu, B.; Fleishmann, G. D.; Gary, D. E.; Kobelski, A.; Wedemeyer, S.; Yan, Y.

    2017-07-01

    The Atacama Large Millimeter/submillimeter Array (ALMA) radio telescope has commenced science observations of the Sun starting in late 2016. Since the Sun is much larger than the field of view of individual ALMA dishes, the ALMA interferometer is unable to measure the background level of solar emission when observing the solar disk. The absolute temperature scale is a critical measurement for much of ALMA solar science, including the understanding of energy transfer through the solar atmosphere, the properties of prominences, and the study of shock heating in the chromosphere. In order to provide an absolute temperature scale, ALMA solar observing will take advantage of the remarkable fast-scanning capabilities of the ALMA 12 m dishes to make single-dish maps of the full Sun. This article reports on the results of an extensive commissioning effort to optimize the mapping procedure, and it describes the nature of the resulting data. Amplitude calibration is discussed in detail: a path that uses the two loads in the ALMA calibration system as well as sky measurements is described and applied to commissioning data. Inspection of a large number of single-dish datasets shows significant variation in the resulting temperatures, and based on the temperature distributions, we derive quiet-Sun values at disk center of 7300 K at λ = 3 mm and 5900 K at λ = 1.3 mm. These values have statistical uncertainties of about 100 K, but systematic uncertainties in the temperature scale that may be significantly larger. Example images are presented from two periods with very different levels of solar activity. At a resolution of about 25'', the 1.3 mm wavelength images show temperatures on the disk that vary over about a 2000 K range. Active regions and plages are among the hotter features, while a large sunspot umbra shows up as a depression, and filament channels are relatively cool. Prominences above the solar limb are a common feature of the single-dish images.

  11. Tidal volume single breath washout of two tracer gases--a practical and promising lung function test.

    Science.gov (United States)

    Singer, Florian; Stern, Georgette; Thamrin, Cindy; Fuchs, Oliver; Riedel, Thomas; Gustafsson, Per; Frey, Urs; Latzin, Philipp

    2011-03-10

    Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI), which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM) and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW) of sulfur hexafluoride (SF(6)) and helium (He) using an ultrasonic flowmeter (USFM). The tracer gas mixture contained 5% SF(6) and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC), were determined in seven subjects performing three SBW 24 hours apart. USFM reliably measured MM during all SBW tests (n = 60). MM from USFM reflected SF(6) and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. The USFM accurately measured relative changes in SF(6) and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF(6) and He washout patterns during tidal breathing.

  12. Tidal volume single breath washout of two tracer gases--a practical and promising lung function test.

    Directory of Open Access Journals (Sweden)

    Florian Singer

    Full Text Available BACKGROUND: Small airway disease frequently occurs in chronic lung diseases and may cause ventilation inhomogeneity (VI, which can be assessed by washout tests of inert tracer gas. Using two tracer gases with unequal molar mass (MM and diffusivity increases specificity for VI in different lung zones. Currently washout tests are underutilised due to the time and effort required for measurements. The aim of this study was to develop and validate a simple technique for a new tidal single breath washout test (SBW of sulfur hexafluoride (SF(6 and helium (He using an ultrasonic flowmeter (USFM. METHODS: The tracer gas mixture contained 5% SF(6 and 26.3% He, had similar total MM as air, and was applied for a single tidal breath in 13 healthy adults. The USFM measured MM, which was then plotted against expired volume. USFM and mass spectrometer signals were compared in six subjects performing three SBW. Repeatability and reproducibility of SBW, i.e., area under the MM curve (AUC, were determined in seven subjects performing three SBW 24 hours apart. RESULTS: USFM reliably measured MM during all SBW tests (n = 60. MM from USFM reflected SF(6 and He washout patterns measured by mass spectrometer. USFM signals were highly associated with mass spectrometer signals, e.g., for MM, linear regression r-squared was 0.98. Intra-subject coefficient of variation of AUC was 6.8%, and coefficient of repeatability was 11.8%. CONCLUSION: The USFM accurately measured relative changes in SF(6 and He washout. SBW tests were repeatable and reproducible in healthy adults. We have developed a fast, reliable, and straightforward USFM based SBW method, which provides valid information on SF(6 and He washout patterns during tidal breathing.

  13. Single large or several small? The influence of prey size on feeding performance of Philodryas nattereri (Squamata: Serpentes

    Directory of Open Access Journals (Sweden)

    Sara Catunda Pereira

    2016-07-01

    Full Text Available This study aimed at evaluating the energetic return and feeding time on Philodryas nattereri kept in captivity. Snakes were fed biweekly for 60 days (four feeding trials, in two different feeding treatments (single and multiple prey items. The energetic return revealed no significant difference between the feeding treatments; however, we found a negative relationship between snake size and prey handling time during a feed using multiple prey items. In P. nattereri, when large preys are as easy to find as small ones, there seems to be no difference in energetic return.

  14. An Efficient Monte Carlo Approach to Compute PageRank for Large Graphs on a Single PC

    Directory of Open Access Journals (Sweden)

    Sonobe Tomohiro

    2016-03-01

    Full Text Available This paper describes a novel Monte Carlo based random walk to compute PageRanks of nodes in a large graph on a single PC. The target graphs of this paper are ones whose size is larger than the physical memory. In such an environment, memory management is a difficult task for simulating the random walk among the nodes. We propose a novel method that partitions the graph into subgraphs in order to make them fit into the physical memory, and conducts the random walk for each subgraph. By evaluating the walks lazily, we can conduct the walks only in a subgraph and approximate the random walk by rotating the subgraphs. In computational experiments, the proposed method exhibits good performance for existing large graphs with several passes of the graph data.

  15. Different body fluid volumes measured by single- and multi-frequency bioelectrical impedance analyzers in overweight/obese renal patients.

    Science.gov (United States)

    Kusztal, Mariusz; Dzierżek, Przemysław; Gołębiowski, Tomasz; Weyde, Wacław; Klinger, Marian

    2015-05-17

    Bioelectrical impedance analysis (BIA) is an affordable, non-invasive and fast alternative method to assess body composition. The purpose of this study was to compare two different tetrapolar BIA devices for estimating body fluid volumes and body cell mass (BCM) in a clinical setting among patients with kidney failure. All double measurements were performed by multi-frequency (MF) and single-frequency (SF) BIA analyzers: a Body Composition Monitor (Fresenius Medical Care, Germany) and BIA-101 (Akern, Italy), respectively. All procedures were conducted according to the manufacturers' instructions (dedicated electrodes, measurement sites, positions, etc). Total body water (TBW), extracellular water (ECW), intracellular water (ICW) and BCM were compared. The study included 39 chronic kidney disease patients (stage III-V) with a mean age of 45.8 ± 8 years (21 men and 18 women) who had a wide range of BMI [17-34 kg/m2 (mean 26.6 ±5)]. A comparison of results from patients with BMI obese renal patients.

  16. Max-Min SINR in Large-Scale Single-Cell MU-MIMO: Asymptotic Analysis and Low Complexity Transceivers

    KAUST Repository

    Sifaou, Houssem

    2016-12-28

    This work focuses on the downlink and uplink of large-scale single-cell MU-MIMO systems in which the base station (BS) endowed with M antennas communicates with K single-antenna user equipments (UEs). Particularly, we aim at reducing the complexity of the linear precoder and receiver that maximize the minimum signal-to-interference-plus-noise ratio subject to a given power constraint. To this end, we consider the asymptotic regime in which M and K grow large with a given ratio. Tools from random matrix theory (RMT) are then used to compute, in closed form, accurate approximations for the parameters of the optimal precoder and receiver, when imperfect channel state information (modeled by the generic Gauss-Markov formulation form) is available at the BS. The asymptotic analysis allows us to derive the asymptotically optimal linear precoder and receiver that are characterized by a lower complexity (due to the dependence on the large scale components of the channel) and, possibly, by a better resilience to imperfect channel state information. However, the implementation of both is still challenging as it requires fast inversions of large matrices in every coherence period. To overcome this issue, we apply the truncated polynomial expansion (TPE) technique to the precoding and receiving vector of each UE and make use of RMT to determine the optimal weighting coefficients on a per- UE basis that asymptotically solve the max-min SINR problem. Numerical results are used to validate the asymptotic analysis in the finite system regime and to show that the proposed TPE transceivers efficiently mimic the optimal ones, while requiring much lower computational complexity.

  17. Effect of high temperature curing on the compressive strength of concrete incorporating large volumes of fly ash

    Energy Technology Data Exchange (ETDEWEB)

    Rivera-Villarreal, R. [Universidad Autonoma de Nuevo Leon, Monterrey (Mexico)

    2001-07-01

    The effect of using different types of heat treatment on the compressive strength of concrete with and without large volumes of fly ash was studied. Curing of concrete is important to obtain a good quality concrete, but it is important to keep concrete from drying until the originally water-filled space in fresh cement paste has been filled to the desired extent by the products of hydration. In hot weather, high temperature promotes faster drying of concrete so a given degree of hydration is reached more rapidly than at lower temperatures. The provision of moist curing is advantageous because of a gradual gain in strength and because of reduced plastic shrinkage and drying shrinkage-cracking. The portland cement content in all the mixtures used in this study was 200 kg per cubic metre and the amount of fly ash varied from 0 to 33, 43, 50 and 56 per cent by mass of the total binder. A superplasticizer was used to obtain 200-220 mm slump. The compressive strength was tested at 3, 7, 14, 28, 56 days and at 6 months. Results showed that, using ASTM standard curing, the compressive strength of portland cement concrete made at 35 degrees C was reduced by about 12 per cent at 28 days compared to that of the concrete made at 23 degrees C. The AASHTO curing strength was found to be a bit higher than with the ASTM curing. The concrete made at 35 degrees C showed no loss of strength when continuous moist-curing was applied. The fly ash concrete mixtures that were cast at 35 degrees C were cured by covering them with membrane curing compounds and placed under ambient conditions. It was crucial to allow enough curing water to promote the pozzolanic reaction. The membrane curing did not allow the ingress of water to the concrete mass. 6 refs., 4 tabs., 13 figs.

  18. Trace analysis of isothiazolinones in water samples by large-volume direct injection liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Speksnijder, P; van Ravestijn, J; de Voogt, P

    2010-08-06

    Isothiazolinones are used as preservatives, biocides and disinfectants in a variety of industrial and domestic applications. Some of the isothiazolinones are difficult to isolate from water due their high polarity. A sensitive and selective analytical method was developed and optimized for the determination of sub-microg/L levels of three isothiazolinones in water samples. Three isothiazolinones are described in this paper: 2-methyl-3-isothiazolinone, 5-chloro-2-methyl-3-isothiazolinone and 4,5-dichloro-2-methyl-3-isothiazolinone. The analytical method involves a robust large-volume direct on-column loop injection of 2 mL on an Aqua ODS HPLC column and tandem MS detection (HPLC-MS/MS). After filtration, samples are directly injected without further pretreatment. Detection limits of the individual target compounds were between 0.03 and 0.1 microg/L employing Multi-Reaction Monitoring (MRM) mass spectrometry. Based on the constant ratio of two selected product-ions together with the retention time, the identification is very selective and quantification is reliable. The method was successfully applied to real samples of membrane flushings, drinking water, surface waters and waste water. Additional investigations showed the instability of the isothiazolinones in river- and waste water. Preservation of river water and waste water samples with sodium azide (NaN(3)) promotes the stability of the isothiazolines in solution. In membrane flushings, waste water, surface waters and drinking water, levels of the three isothiazolinones were all below the limit of detection. In effluents of households containing washings from normal shampoo use, isothiazolinones could be detected. Copyright 2010 Elsevier B.V. All rights reserved.

  19. Research on volume metrology method of large vertical energy storage tank based on internal electro-optical distance-ranging method

    Science.gov (United States)

    Hao, Huadong; Shi, Haolei; Yi, Pengju; Liu, Ying; Li, Cunjun; Li, Shuguang

    2018-01-01

    A Volume Metrology method based on Internal Electro-optical Distance-ranging method is established for large vertical energy storage tank. After analyzing the vertical tank volume calculation mathematical model, the key processing algorithms, such as gross error elimination, filtering, streamline, and radius calculation are studied for the point cloud data. The corresponding volume values are automatically calculated in the different liquids by calculating the cross-sectional area along the horizontal direction and integrating from vertical direction. To design the comparison system, a vertical tank which the nominal capacity is 20,000 m3 is selected as the research object, and there are shown that the method has good repeatability and reproducibility. Through using the conventional capacity measurement method as reference, the relative deviation of calculated volume is less than 0.1%, meeting the measurement requirements. And the feasibility and effectiveness are demonstrated.

  20. Characterization of Distinct Astrocytic Populations Responding with Different Volume Changes to Oxygen-Glucose Deprivation: 3d Confocal Morphometry And Single-Cell Gene Expression Profilig

    Czech Academy of Sciences Publication Activity Database

    Benešová, Jana; Rusňáková, Vendula; Honsa, Pavel; Pivoňková, Helena; Kubista, Mikael; Anděrová, Miroslava

    2011-01-01

    Roč. 59, Supplement 1 (2011), S126-S126 ISSN 0894-1491. [European meeting on Glial Cells in Health and Disease /10./. 13.09.2011-13.09.2011, Prague] Institutional research plan: CEZ:AV0Z50390703; CEZ:AV0Z50520701 Keywords : cell volume regulation * single-cell PCR profiling * ischemia Subject RIV: FH - Neurology

  1. Dysphagia is prevalent in patients with CPEO and single, large-scale deletions in mtDNA

    DEFF Research Database (Denmark)

    Pedersen, Gitte Hedermann; Løkken, Nicoline; Dahlqvist, Julia R.

    2017-01-01

    Background  The aim of this study was to assess the frequency of subjective and objective dysphagia in patients with chronic progressive external ophthalmoplegia (CPEO) due to single, large-scale deletions (LSDs) of mitochondrial DNA (mtDNA). Methods  Sixteen patients with CPEO and single LSDs...... and single LSDs of mtDNA had a prolonged cold-water test, including one with a PEG-tube, who was unable to perform the test, and nine patients reported subjective swallowing problems (56.3%). All mitochondrial myopathy patients in the control group had a normal duration of the cold-water test.  Conclusions......  The study shows that dysphagia is a common problem in patients with CPEO and LSDs of mtDNA. Dysphagia seems to be progressive with age as abnormal swallowing occurred preferentially in persons ≥ 45 years. The study shows that increased awareness of this symptom should be given to address appropriate...

  2. Characterization of radiation exposure and effect of a radiation monitoring policy in a large volume pediatric cardiac catheterization lab.

    Science.gov (United States)

    Verghese, George R; McElhinney, Doff B; Strauss, Keith J; Bergersen, Lisa

    2012-02-01

    This study aimed to characterize radiation dose during cardiac catheterization in congenital heart disease and to assess changes in dose after the introduction of a radiation monitoring policy. Minimizing radiation exposure is an important patient safety initiative and relatively few data are available characterizing radiation dose for the broad spectrum of congenital cardiac catheter-based interventions. Radiation dose data were reviewed on all cases since 7/1/05 at a single large center. Procedures were classified according to 20 common case types then subdivided into five age categories. Groups with product, μGym(2)) which were reported as median and interquartile range (IQR). We also examined differences in radiation dose before and after the implementation of a radiation policy. Between 7/1/05 and 12/10/08, 3,365 cases were identified for inclusion. Radiation dose increased with age and procedural complexity. Patients were characterized into low, medium, and high dose categories relative to each other. "Low" dose cases included isolated pulmonary or aortic valvotomy, pre-Fontan assessment, and ASD closure. "High" dose cases involved multiple procedures in pulmonary arteries or veins. After introduction of a radiation policy, there was a significant decrease in radiation dose across a variety of case types, particularly among infants and young children. Radiation dose in congenital cardiac catheterization varies by age and procedure type. A radiation monitoring and notification policy may have contributed to reduced radiation dose. Copyright © 2011 Wiley Periodicals, Inc.

  3. Large-volume low apparent diffusion coefficient lesions predict poor survival in bevacizumab-treated glioblastoma patients

    Science.gov (United States)

    Zhang, Myron; Gulotta, Bryanna; Thomas, Alissa; Kaley, Thomas; Karimi, Sasan; Gavrilovic, Igor; Woo, Kaitlin M.; Zhang, Zhigang; Arevalo-Perez, Julio; Holodny, Andrei I.; Rosenblum, Marc; Young, Robert J.

    2016-01-01

    Background Glioblastomas treated with bevacizumab may develop low-signal apparent diffusion coefficient (low-ADC) lesions, which may reflect increased tumor cellularity or atypical necrosis. The purpose of this study was to examine the relationship between low-ADC lesions and overall survival (OS). We hypothesized that growing low-ADC lesions would be associated with shorter OS. Methods We retrospectively identified 52 patients treated with bevacizumab for the first (n = 42, 81%) or later recurrence of primary glioblastoma, who had low-ADC lesions and 2 post-bevacizumab scans ≤90 days apart. Low-ADC lesion volumes were measured, and normalized 5th percentile histogram low-ADC values were recorded. Using OS as the primary endpoint, semiparametric Cox models were fitted to ascertain univariate and multivariate hazard ratios (HRs) with significance at P = .05. Results Median OS was 9.1 months (95% CI = 7.2–14.3). At the second post-bevacizumab scan, the volume of the low-ADC lesion (median: 12.94 cm3) was inversely associated with OS, with larger volumes predicting shorter OS (HR = 1.014 [95% CI = 1.003–1.025], P = .009). The percent change in low-ADC volume (median: 6.8%) trended toward increased risk of death with growing volumes (P = .08). Normalized 5th percentile low-ADC value and its percent change were not associated with OS (P > .51). Also correlated with shorter OS were the pre-bevacizumab nonenhancing volume (P = .025), the first post-bevacizumab enhancing volume (P = .040), and the second post-bevacizumab enhancing volume (P = .004). Conclusions The volume of low-ADC lesions at the second post-bevacizumab scan predicted shorter OS. This suggests that low-ADC lesions may be considered important imaging markers and included in treatment decision algorithms. PMID:26538618

  4. Single-beat versus multibeat real-time 3D echocardiography for assessing left ventricular volumes and ejection fraction: a comparison study with cardiac magnetic resonance.

    Science.gov (United States)

    Macron, Laurent; Lim, Pascal; Bensaid, Alexandre; Nahum, Julien; Dussault, Caroline; Mitchell-Heggs, Laurens; Dubois-Randé, Jean-Luc; Deux, Jean-François; Gueret, Pascal

    2010-07-01

    Real-time 3-dimensional echocardiography (RT3DE) is superior to 2D echocardiography in assessing left ventricular (LV) volumes and ejection fraction (EF), but its feasibility is limited by multibeat acquisition, which requires an optimal breath-hold and a regular heart rhythm. We sought to evaluate the accuracy and feasibility of single- and 2-beat RT3DE for LV volume and EF assessment. Sixty-six consecutive patients referred for cardiac magnetic resonance (CMR) underwent RT3DE and CMR on the same day. Of the 50 patients (age, 59+/-18 years; 68%men; 42% coronary artery disease; LVEF=49+/-14%; limits, 14% to 76%) with an adequate RT3DE image quality, accuracy for LV volumes and EF measurements of single- and 2-beat modalities were compared with the conventional 4-beat acquisition and CMR. Correlations with CMR for LV end-diastolic volume (161+/-59 mL, r=0.93 to 0.94) and end-systolic volume (86+/-56 mL, r=0.93 to 0.96) were excellent regardless of the number of cardiac cycles used. However, because of the low temporal resolution (7+/-2 volumes per second), single-beat underestimated LVEF (bias, -5+/-8%) with greater bias than 2-beat (bias, 1+/-6%, P<0.001) and 4-beat (bias, 3+/-7%, P<0.001) modalities. Interestingly, 2-beat provided accuracy similar to 4-beat for end-diastolic volume (bias, -17+/-21 mL versus -15+/-23 mL), end-systolic volume (bias, -9+/-16 mL versus -12+/-17 mL), and LVEF (bias, 1+/-6% versus 3+/-7%) measurements, but fewer stitching artifacts were observed with 2- than 4-beat modalities (3% versus 30%). Compared with conventional multibeat acquisitions, 2-beat modality provides similar accuracy in LV volume and EF measurements and should be preferred due to fewer stitching artifacts. In contrast, the temporal resolution of single-beat modality appears insufficient to provide an accurate estimation of LVEF.

  5. Behavior and role of superficial oxygen in Cu for the growth of large single-crystalline graphene

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Dong [Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka 816-8580 (Japan); Solís-Fernández, Pablo [Global Innovation Center (GIC), Kyushu University, Fukuoka, 816-8580 (Japan); Yunus, Rozan Mohamad [Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka 816-8580 (Japan); Hibino, Hiroki [School of Science and Technology, Kwansei Gakuin University, Hyogo, 669-1337 (Japan); Ago, Hiroki, E-mail: ago.hiroki.974@m.kyushu-u.ac.jp [Interdisciplinary Graduate School of Engineering Sciences, Kyushu University, Fukuoka 816-8580 (Japan); Global Innovation Center (GIC), Kyushu University, Fukuoka, 816-8580 (Japan)

    2017-06-30

    Highlights: • Growth mechanism of large graphene grains on oxidized Cu was revealed by investigating the behavior of oxygen in the Cu. • Only the heating up step was found to be crucial for obtaining large graphene grains. • The copper oxide layer was found to promote some oxygen atoms to dissolve into the Cu foil. • The dissolved oxygen contributes to the reduction of a nucleation density of graphene. - Abstract: Decreasing the nucleation density of graphene grown on copper (Cu) foil by chemical vapor deposition (CVD) is essential for the synthesis of large-area single-crystalline graphene. Here, the behavior of the copper oxide layer and its impact on the graphene growth have been investigated. We found that a small amount of oxygen dissolves into the Cu when the oxide layer decomposes during the heating up in a non-reducing Ar environment. The remaining oxygen in the Cu foil can play an important role in decreasing the graphene nucleation density. The dissolved oxygen can withstand at high temperatures even in reducing H{sub 2} environments without completely losing its effectiveness for maintaining a low graphene nucleation density. However, heating up in a H{sub 2} environment significantly reduces the copper oxide layer during the very first moments of the process at low temperatures, preventing the oxygen to dissolve into the Cu and significantly increasing the nucleation density. These findings will help to improve the graphene growth on Cu catalyst by increasing the grain size while decreasing the grain density.

  6. Serial prostate biopsy and risk of lower urinary tract symptoms: results from a large, single-institution active surveillance cohort.

    Science.gov (United States)

    Glass, Allison S; Hilton, Joan F; Cowan, Janet E; Washington, Samuel L; Carroll, Peter R

    2014-01-01

    To describe the effect of serial prostate biopsy on lower urinary tract symptoms (LUTS) in men who undergo active surveillance (AS) at a large academic institution. This is a retrospective study of men enrolled in AS for ≥6 months who underwent ≥1 biopsy and completed ≥1 International Prostate Symptom Score (IPSS) questionnaire. In additional to total IPSS, we report the mean difference between the first and last questionnaires for patients who completed ≥2 questionnaires. Multivariate models, adjusting for disease features, age, race, prostate volume and baseline, or incident benign prostatic hypertrophy (BPH), were used to assess relationships between IPSS and total biopsy exposure. Four hundred eighty-two men were eligible, and 291 completed ≥2 IPSS questionnaires. Overall, mean (standard deviation) age was 61.7 (7.8) years, and median prostate volume (interquartile range) was 42 (34-61) mL. At baseline, 11% provided history of BPH. Among men who completed multiple questionnaires, 25% experienced clinically significant worsening (IPSS increase ≥4 points). In regression model, total IPSS was not significantly associated with greater biopsy exposure (P = .25). IPSS change from initial and the latest questionnaire was not significantly associated with initial or interval biopsy exposure in an adjusted longitudinal model (P = .64 and .50, respectively), but a trend was observed with greater age decade (+4.07 points, 95% CI -0.30 to 8.4; P = .07). Repeated prostate biopsy does not appear to independently pose additional risk of LUTS in an AS population. In unadjusted analyses, greater biopsy exposure is a surrogate for increasing follow-up time, age, and BPH risk, and thus, risk of LUTS onset and progression. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. The biological effect of large single doses: a possible role for non-targeted effects in cell inactivation.

    Directory of Open Access Journals (Sweden)

    Marlon R Veldwijk

    Full Text Available BACKGROUND AND PURPOSE: Novel radiotherapy techniques increasingly use very large dose fractions. It has been argued that the biological effect of large dose fractions may differ from that of conventional fraction sizes. The purpose was to study the biological effect of large single doses. MATERIAL AND METHODS: Clonogenic cell survival of MCF7 and MDA-MB-231 cells was determined after direct X-ray irradiation, irradiation of feeder cells, or transfer of conditioned medium (CM. Cell-cycle distributions and the apoptotic sub-G1 fraction were measured by flow cytometry. Cytokines in CM were quantified by a cytokine antibody array. γH2AX foci were detected by immunofluorescence microscopy. RESULTS: The surviving fraction of MCF7 cells irradiated in vitro with 12 Gy showed an 8.5-fold decrease (95% c.i.: 4.4-16.3; P<0.0001 when the density of irradiated cells was increased from 10 to 50×10(3 cells per flask. Part of this effect was due to a dose-dependent transferrable factor as shown in CM experiments in the dose range 5-15 Gy. While no effect on apoptosis and cell cycle distribution was observed, and no differentially expressed cytokine could be identified, the transferable factor induced prolonged expression of γH2AX DNA repair foci at 1-12 h. CONCLUSIONS: A dose-dependent non-targeted effect on clonogenic cell survival was found in the dose range 5-15 Gy. The dependence of SF on cell numbers at high doses would represent a "cohort effect" in vivo. These results support the hypothesis that non-targeted effects may contribute to the efficacy of very large dose fractions in radiotherapy.

  8. Shock-induced plasticity in tantalum single crystals: Interatomic potentials and large-scale molecular-dynamics simulations

    Science.gov (United States)

    Ravelo, R.; Germann, T. C.; Guerrero, O.; An, Q.; Holian, B. L.

    2013-10-01

    We report on large-scale nonequilibrium molecular dynamics simulations of shock wave compression in tantalum single crystals. Two new embedded atom method interatomic potentials of Ta have been developed and optimized by fitting to experimental and density functional theory data. The potentials reproduce the isothermal equation of state of Ta up to 300 GPa. We examined the nature of the plastic deformation and elastic limits as functions of crystal orientation. Shock waves along (100), (110), and (111) exhibit elastic-plastic two-wave structures. Plastic deformation in shock compression along (110) is due primarily to the formation of twins that nucleate at the shock front. The strain-rate dependence of the flow stress is found to be orientation dependent, with (110) shocks exhibiting the weaker dependence. Premelting at a temperature much below that of thermodynamic melting at the shock front is observed in all three directions for shock pressures above about 180 GPa.

  9. MEGAHIT: an ultra-fast single-node solution for large and complex metagenomics assembly via succinct de Bruijn graph.

    Science.gov (United States)

    Li, Dinghua; Liu, Chi-Man; Luo, Ruibang; Sadakane, Kunihiko; Lam, Tak-Wah

    2015-05-15

    MEGAHIT is a NGS de novo assembler for assembling large and complex metagenomics data in a time- and cost-efficient manner. It finished assembling a soil metagenomics dataset with 252 Gbps in 44.1 and 99.6 h on a single computing node with and without a graphics processing unit, respectively. MEGAHIT assembles the data as a whole, i.e. no pre-processing like partitioning and normalization was needed. When compared with previous methods on assembling the soil data, MEGAHIT generated a three-time larger assembly, with longer contig N50 and average contig length; furthermore, 55.8% of the reads were aligned to the assembly, giving a fourfold improvement. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  10. Efficient injection from large telescopes into single-mode fibres: Enabling the era of ultra-precision astronomy

    Science.gov (United States)

    Jovanovic, N.; Schwab, C.; Guyon, O.; Lozi, J.; Cvetojevic, N.; Martinache, F.; Leon-Saval, S.; Norris, B.; Gross, S.; Doughty, D.; Currie, T.; Takato, N.

    2017-08-01

    Photonic technologies offer numerous advantages for astronomical instruments such as spectrographs and interferometers owing to their small footprints and diverse range of functionalities. Operating at the diffraction-limit, it is notoriously difficult to efficiently couple such devices directly with large telescopes. We demonstrate that with careful control of both the non-ideal pupil geometry of a telescope and residual wavefront errors, efficient coupling with single-mode devices can indeed be realised. A fibre injection was built within the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) instrument. Light was coupled into a single-mode fibre operating in the near-IR (J - H bands) which was downstream of the extreme adaptive optics system and the pupil apodising optics. A coupling efficiency of 86% of the theoretical maximum limit was achieved at 1550 nm for a diffraction-limited beam in the laboratory, and was linearly correlated with Strehl ratio. The coupling efficiency was constant to within 40% for 84% of the time and >50% for 41% of the time. The laboratory results allow us to forecast that extreme adaptive optics levels of correction (Strehl ratio >90% in H-band) would allow coupling of >67% (of the order of coupling to multimode fibres currently) while standard levels of wavefront correction (Strehl ratio >20% in H-band) would allow coupling of >18%. For Strehl ratios <20%, few-port photonic lanterns become a superior choice but the signal-to-noise, and pixel availability must be considered. These results illustrate a clear path to efficient on-sky coupling into a single-mode fibre, which could be used to realise modal-noise-free radial velocity machines, very-long-baseline optical/near-IR interferometers and/or simply exploit photonic technologies in future instrument design.

  11. Multispectral absorptance from large-diameter InAsSb nanowire arrays in a single epitaxial growth on silicon

    Science.gov (United States)

    Robson, Mitchell; Azizur-Rahman, Khalifa M.; Parent, Daniel; Wojdylo, Peter; Thompson, David A.; LaPierre, Ray R.

    2017-12-01

    Vertical III-V nanowires are capable of resonant absorption at specific wavelengths by tuning the nanowire diameter, thereby exceeding the absorption of equivalent thin films. These properties may be exploited to fabricate multispectral infrared (IR) photodetectors, directly integrated with Si, without the need for spectral filters or vertical stacking of heterostructures as required in thin film devices. In this study, multiple InAsSb nanowire arrays were grown simultaneously on Si by molecular beam epitaxy with nanowire diameter controlled by the nanowire period (spacing between nanowires). This is the first such study of patterned InAsSb nanowires where control of nanowire diameter and multispectral absorption are demonstrated. The antimony flux was used to control axial and radial growth rates using a selective-area catalyst-free growth method, achieving large diameters, spanning 440–520 nm, which are necessary for optimum IR absorption. Fourier transform IR spectroscopy revealed IR absorptance peaks due to the HE11 resonance of the nanowire arrays in agreement with optical simulations. Due to the dependence of the HE11 resonance absorption on nanowire diameter, multispectral absorption was demonstrated in a single material system and a single epitaxial growth step without the need for bandgap tuning. This work demonstrates the potential of InAsSb nanowires for multispectral photodetectors and sensor arrays in the short-wavelength IR region.

  12. Cell volumes of marine phytoplankton from globally distributed coastal data sets

    Digital Repository Service at National Institute of Oceanography (India)

    Harrison, P.J.; Zingone, A.; Mickelson, M.J.; Lehtinen, S.; Ramaiah, N.; Kraberg, A.C.; Sun, J.; McQuatters-Gollop, A.; Jakobsen, H.H.

    volumes are the single largest source of uncertainty in community phytoplankton carbon estimates and greatly exceeds the uncertainty associated with the different volume to carbon estimates. Small diatoms have 10 times more carbon density than large...

  13. Effect of partial volume correction on muscarinic cholinergic receptor imaging with single-photon emission tomography in patients with temporal lobe epilepsy

    International Nuclear Information System (INIS)

    Weckesser, M.; Ziemons, K.; Griessmeier, M.; Sonnenberg, F.; Langen, K.J.; Mueller-Gaertner, H.W.; Hufnagel, A.; Elger, C.E.; Hacklaender, T.; Holschbach, M.

    1997-01-01

    Animal experiments and preliminary results in humans have indicated alterations of hippocampal muscarinic acetylcholine receptors (mAChR) in temporal lobe epilepsy. Patients with temporal lobe epilepsy often present with a reduction in hippocampal volume. The aim of this study was to investigate the influence of hippocampal atrophy on the quantification of mAChR with single photon emission tomography (SPET) in patients with temporal lobe epilepsy. Cerebral uptake of the muscarinic cholinergic antagonist [ 123 I]4-iododexetimide (IDex) was investigated by SPET in patients suffering from temporal lobe epilepsy of unilateral (n=6) or predominantly unilateral (n=1) onset. Regions of interest were drawn on co-registered magnetic resonance images. Hippocampal volume was determined in these regions and was used to correct the SPET results for partial volume effects. A ratio of hippocampal IDex binding on the affected side to that on the unaffected side was used to detect changes in muscarinic cholinergic receptor density. Before partial volume correction a decrease in hippocampal IDex binding on the focus side was found in each patient. After partial volume no convincing differences remained. Our results indicate that the reduction in hippocampal IDex binding in patients with epilepsy is due to a decrease in hippocampal volume rather than to a decrease in receptor concentration. (orig.). With 2 figs., 2 tabs

  14. Initial steps toward the realization of large area arrays of single photon counting pixels based on polycrystalline silicon TFTs

    Science.gov (United States)

    Liang, Albert K.; Koniczek, Martin; Antonuk, Larry E.; El-Mohri, Youcef; Zhao, Qihua; Jiang, Hao; Street, Robert A.; Lu, Jeng Ping

    2014-03-01

    The thin-film semiconductor processing methods that enabled creation of inexpensive liquid crystal displays based on amorphous silicon transistors for cell phones and televisions, as well as desktop, laptop and mobile computers, also facilitated the development of devices that have become ubiquitous in medical x-ray imaging environments. These devices, called active matrix flat-panel imagers (AMFPIs), measure the integrated signal generated by incident X rays and offer detection areas as large as ~43×43 cm2. In recent years, there has been growing interest in medical x-ray imagers that record information from X ray photons on an individual basis. However, such photon counting devices have generally been based on crystalline silicon, a material not inherently suited to the cost-effective manufacture of monolithic devices of a size comparable to that of AMFPIs. Motivated by these considerations, we have developed an initial set of small area prototype arrays using thin-film processing methods and polycrystalline silicon transistors. These prototypes were developed in the spirit of exploring the possibility of creating large area arrays offering single photon counting capabilities and, to our knowledge, are the first photon counting arrays fabricated using thin film techniques. In this paper, the architecture of the prototype pixels is presented and considerations that influenced the design of the pixel circuits, including amplifier noise, TFT performance variations, and minimum feature size, are discussed.

  15. Automated large-volume sample stacking procedure to detect labeled peptides at picomolar concentration using capillary electrophoresis and laser-induced fluorescence detection.

    Science.gov (United States)

    Siri, Nathalie; Riolet, Pierre; Bayle, Christophe; Couderc, François

    2003-08-05

    We have developed an automated large-volume sample stacking (LVSS) procedure to detect fluorescein isothiocyanate-labeled peptides in the picomolar range. The injection duration is 10 min at 50 mbar to fill 62% of the capillary volume to the detection cell. The calculated limit of detection (S/N=3), filling 1% of the capillary volume, is 74 pM for bradykinin and 45 pM for L-enkephalin with samples diluted in water and analyzed in a 50 mM borate buffer, pH 9.2. With the automated LVSS system, the limits of detection are 7 pM for bradykinin, 3 pM for L-enkephalin and 2 pM for substance P. LVSS is shown to be quantitative from 500 to 10 pM.

  16. Derivation and representation of dose-volume response from large clinical trial data sets: an example from the RADAR prostate radiotherapy trial

    Science.gov (United States)

    Ebert, M. A.; Foo, K.; Haworth, A.; Gulliford, S. L.; Kearvall, R.; Kennedy, A.; Richardson, S.; Krawiec, M.; Stewart, N.; Joseph, D. J.; Denham, J. W.

    2014-03-01

    Large multicentre radiotherapy trials incorporating assessment of multiple outcomes at multiple timepoints can generate extensive datasets. We have investigated graphical techniques for presentation of this data and the associated underlying dose-volume response information, necessary for guiding statistical analyses and translating outcomes to future patient treatments. A relational database was used to archive reviewed plan data for patients accrued to the TROG 03.04 RADAR trial. Viewing software was used to clean and enhance the data. Scripts were developed to export arbitrary dose-histogram data which was combined with clinical toxicity data with a median follow-up of 72 months. Graphical representations of dose-volume response developed include prevalence atlasing, univariate logistic regression and dose-volume-point odds ratios, and continuous cut-point derivation via ROC analysis. These representations indicate variable association of toxicities across structures and time-points.

  17. Crash problem definition and safety benefits methodology for stability control for single-unit medium and heavy trucks and large-platform buses

    Science.gov (United States)

    2009-10-01

    This report presents the findings of a comprehensive engineering analysis of electronic stability control (ESC) and roll stability control (RSC) systems for single-unit medium and heavy trucks and large-platform buses. This report details the applica...

  18. Growing vertical ZnO nanorod arrays within graphite: efficient isolation of large size and high quality single-layer graphene.

    Science.gov (United States)

    Ding, Ling; E, Yifeng; Fan, Louzhen; Yang, Shihe

    2013-07-18

    We report a unique strategy for efficiently exfoliating large size and high quality single-layer graphene directly from graphite into DMF dispersions by growing ZnO nanorod arrays between the graphene layers in graphite.

  19. Quantifying the Impact of Immediate Reconstruction in Postmastectomy Radiation: A Large, Dose-Volume Histogram-Based Analysis

    International Nuclear Information System (INIS)

    Ohri, Nisha; Cordeiro, Peter G.; Keam, Jennifer; Ballangrud, Ase; Shi Weiji; Zhang Zhigang; Nerbun, Claire T.; Woch, Katherine M.; Stein, Nicholas F.; Zhou Ying; McCormick, Beryl; Powell, Simon N.; Ho, Alice Y.

    2012-01-01

    Purpose: To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Methods and Materials: Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Results: Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P 98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P .05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Conclusions: Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary determinant of target coverage and normal tissue doses.

  20. System of large transport containers for waste from dismantling light water and gas-cooled nuclear reactors. Volume 1

    International Nuclear Information System (INIS)

    Price, M.S.T.; Lafontaine, I.

    1985-01-01

    The purpose of this volume is to introduce the main types of nuclear reactor in the European Community (EC), select reference plants for further study, estimate the waste streams from the reference reactors, survey the transport regulations and assess existing containers

  1. Single-Sex Education in the 21st Century. Education Policy Brief. Volume 6, Number 9, Fall 2008

    Science.gov (United States)

    Cable, Kelly E.; Spradlin, Terry E.

    2008-01-01

    Single-sex education describes a diverse range of situations, including individual classes, programs after school, required programs, voluntary programs, and programs to remedy gender inequities and encourage cultural and racial pride. This brief addresses the genesis and legality of single-sex classrooms, the merits and critiques of single-sex…

  2. Determination of blood leukocyte concentration with constant volume acquisition on a flow cytometer is comparable to individualized single platform testing with beads as internal reference standard

    DEFF Research Database (Denmark)

    Hansen, Susan; Dahl, Ronald; Hoffmann, Hans Jürgen

    2008-01-01

    Flow cytometers have a constant flow rate. This enables flow cytometers to measure leukocyte concentrations in a determined volume by acquiring data at a fixed rate over a fixed time and is called constant volume acquisition (CVA). The volume aspirated by a FACS Calibur flow cytometer in 4 min...... at a high rate has a median of 163 microl (IQR 156-170) with TruCount tubes. Leukocyte concentrations of 26 healthy volunteers were measured twice on up to four occasions with a Bürker-Türk chamber, by single platform technology (SPT) with TruCount tubes and on the same data set using CVA. Total leukocyte...... concentrations determined by CVA correlated better with measurements in a Bürker-Türk (BT) chamber than with SPT. Concentrations determined with CVA were 1.86% higher than with BT whereas SPT data were 5.35% higher than BT (pconcentrations

  3. Effects of large gut volume in gelatinous zooplankton: ingestion rate, bolus production and food patch utilization by the jellyfish Sarsia tubulosa

    DEFF Research Database (Denmark)

    Hansson, L.J.; Kiørboe, Thomas

    2006-01-01

    for a long time was illustrated with calculations of prey uptake by S. tubulosa feeding in prey concentrations of variable heterogeneity. The ability of jellyfish to capture prey at maximum clearance rate under different prey concentrations, and to accumulate relatively large amounts of food in their guts...... or with jellyfish that were pre-adjusted to the food concentration before incubation. The findings have implications for design and interpretation of experiments. The possibility for jellyfish to feed at maximum clearance rate in either very high prey concentration for a short time or low prey concentration......Many gelatinous zooplankton consume a large amount of prey and have stomach volumes much greater than the volume of individual prey. We suggest that jellyfish can use their voluminous stomach as a buffering food-accumulating organ that allows the organism to feed at maximum clearance rate in a wide...

  4. New methods to interpolate large volume of data from points or particles (Mesh-Free) methods application for its scientific visualization

    International Nuclear Information System (INIS)

    Reyes Lopez, Y.; Yervilla Herrera, H.; Viamontes Esquivel, A.; Recarey Morfa, C. A.

    2009-01-01

    In the following paper we developed a new method to interpolate large volumes of scattered data, focused mainly on the results of the Mesh free Methods, Points Methods and the Particles Methods application. Through this one, we use local radial basis function as interpolating functions. We also use over-tree as the data structure that allows to accelerate the localization of the data that influences to interpolate the values at a new point, speeding up the application of scientific visualization techniques to generate images from large data volumes from the application of Mesh-free Methods, Points and Particle Methods, in the resolution of diverse models of physics-mathematics. As an example, the results obtained after applying this method using the local interpolation functions of Shepard are shown. (Author) 22 refs

  5. A single-institution experience: the integrated vascular surgery residency's effect on fellowship and general surgery resident case volume and diversity.

    Science.gov (United States)

    Carroll, Megan I; Downes, Kathryne; Miladinovic, Branko; Illig, Karl A; Armstrong, Paul A; Back, Martin R; Johnson, Brad L; Shames, Murray L

    2014-01-01

    To determine whether the formation of an integrated vascular surgery residency (0 + 5) has negatively impacted the case volume and diversity of the vascular surgery fellows (5 + 2) and chief general surgeons at the same institution. Operative data from the vascular integrated (0 + 5), independent (5 + 2), and general surgery residencies at a single institution were retrospectively reviewed and analyzed to determine vascular surgery case volumes from 2006-2012. National operative data (Residency Review Committee) were used for comparison of diversity and volume. Standard statistical methods were applied. During this period, the 5 + 2 fellows at our institution performed on average 741 (range, 554-1002) primary cases and 1091 (range, 844-1479) combined primary and secondary cases for the 2-year fellowship. Our integrated residency began in July 2007. Our fellows' primary case volumes remained relatively stable between 2006 and 2011, with a 4% increase in the number of cases, although their total (primary and secondary) case volumes fell 15%; by comparison, the equivalent national 50th percentile rates rose 16% during this time frame. Our institution's general surgery residents performed an average of 116 (range, 56-221) vascular cases individually during their 5-year residency from 2005-2011. From 2006-2011, the total case volume fell only 5%, while the national 50th percentile rate fell 24%. Across all years, however, resident and fellow volumes both continue to be above Accreditation Council for Graduate Medical Education minimum requirements, and the major vascular case volume at our institution in all groups studied remained statistically greater than or equal to the national 50th percentile of cases. Our first integrated resident to graduate finished in June 2012 with 931 total vascular cases and 249 general surgery cases for a total operative experience of 1180 cases during the 5-year residency. Finally, after an 8-year period (2003-2010) in which none of

  6. A novel porous bioceramics scaffold by accumulating hydroxyapatite spherulites for large bone tissue engineering in vivo. II. Construct large volume of bone grafts.

    Science.gov (United States)

    Zhi, Wei; Zhang, Cong; Duan, Ke; Li, Xiaohong; Qu, Shuxin; Wang, Jianxin; Zhu, Zhuoli; Huang, Peng; Xia, Tian; Liao, Ga; Weng, Jie

    2014-08-01

    In vivo engineering of bone autografts using bioceramic scaffolds with appropriate porous structures is a potential approach to prepare autologous bone grafts for the repair of critical-sized bone defects. This study investigated the evolutionary process of osteogenesis, angiogenesis, and compressive strength of bioceramic scaffolds implanted in two non-osseous sites of dogs: the abdominal cavity and the dorsal muscle. Hydroxyapatite (HA) sphere-accumulated scaffolds with controlled porous structures were prepared and placed in the two sites for up to 6 months. Analyses of retrieved scaffolds found that osteogenesis and angiogenesis were faster in scaffolds implanted in dorsal muscles compared with those placed in abdominal cavities. The abdominal cavity, however, can accommodate larger bone grafts with designed shape. Analyses of scaffolds implanted in abdominal cavities [an environment of a low mesenchymal stem cell (MSC) density] further demonstrated that angiogenesis play critical roles during osteogenesis in the scaffolds, presumably by supplying progenitor cells and/or MSCs as seed cells. This study also examined the relationship between the volume of bone grafts and the physiological environment of in vivo bioreactor. These results provide basic information for the selection of appropriate implanting sites and culture time required to engineer autologous bone grafts for the clinical bone defect repair. Based on these positive results, a pilot study has applied the grafts constructed in canine abdominal cavity to repair segmental bone defect in load-bearing sites (limbs). © 2013 Wiley Periodicals, Inc.

  7. Presentation, management and outcomes in acute pituitary apoplexy: a large single-centre experience from the United Kingdom.

    Science.gov (United States)

    Bujawansa, S; Thondam, S K; Steele, C; Cuthbertson, D J; Gilkes, C E; Noonan, C; Bleaney, C W; Macfarlane, I A; Javadpour, M; Daousi, C

    2014-03-01

    To study the presentation, management and outcomes and to apply retrospectively the Pituitary Apoplexy Score (PAS) (United Kingdom (UK) guidelines for management of apoplexy) to a large, single-centre series of patients with acute pituitary apoplexy. Retrospective analysis of casenotes at a single neurosurgical centre in Liverpool, UK. Fifty-five patients [mean age, 52·4 years; median duration of follow-up, 7 years] were identified; 45 of 55 (81%) had nonfunctioning adenomas, four acromegaly and six prolactinomas. Commonest presenting features were acute headache (87%), diplopia (47·2%) and visual field (VF) defects (36%). The most frequent ocular palsy involved the 3rd nerve (81%), followed by 6th nerve (34·6%) and multiple palsies (19%). Twenty-three patients were treated conservatively, and the rest had surgery either within 7 days of presentation or delayed elective surgery. Indications for surgery were deteriorating visual acuity and persistent field defects. Patients presenting with VF defects (n = 20) were more likely to undergo surgery (75%) than to be managed expectantly (25%). There was no difference in the rates of complete/near-complete resolution of VF deficits and cranial nerve palsies between those treated conservatively and those who underwent surgery. Endocrine outcomes were also similar. We were able to calculate the PAS for 46 patients: for the group treated with early surgery mean, PAS was 3·8 and for those managed conservatively or with delayed surgery was 1·8. Patients without VF deficits or whose visual deficits are stable or improving can be managed expectantly without negative impact on outcomes. Clinical severity based on a PAS ≥ 4 appeared to influence management towards emergency surgical intervention. © 2013 John Wiley & Sons Ltd.

  8. Technical Failure of MR Elastography Examinations of the Liver: Experience from a Large Single-Center Study.

    Science.gov (United States)

    Wagner, Mathilde; Corcuera-Solano, Idoia; Lo, Grace; Esses, Steven; Liao, Joseph; Besa, Cecilia; Chen, Nelson; Abraham, Ginu; Fung, Maggie; Babb, James S; Ehman, Richard L; Taouli, Bachir

    2017-08-01

    Purpose To assess the determinants of technical failure of magnetic resonance (MR) elastography of the liver in a large single-center study. Materials and Methods This retrospective study was approved by the institutional review board. Seven hundred eighty-one MR elastography examinations performed in 691 consecutive patients (mean age, 58 years; male patients, 434 [62.8%]) in a single center between June 2013 and August 2014 were retrospectively evaluated. MR elastography was performed at 3.0 T (n = 443) or 1.5 T (n = 338) by using a gradient-recalled-echo pulse sequence. MR elastography and anatomic image analysis were performed by two observers. Additional observers measured liver T2* and fat fraction. Technical failure was defined as no pixel value with a confidence index higher than 95% and/or no apparent shear waves imaged. Logistic regression analysis was performed to assess potential predictive factors of technical failure of MR elastography. Results The technical failure rate of MR elastography at 1.5 T was 3.5% (12 of 338), while it was higher, 15.3% (68 of 443), at 3.0 T. On the basis of univariate analysis, body mass index, liver iron deposition, massive ascites, use of 3.0 T, presence of cirrhosis, and alcoholic liver disease were all significantly associated with failure of MR elastography (P analysis, only body mass index, liver iron deposition, massive ascites, and use of 3.0 T were significantly associated with failure of MR elastography (P technical failure rate of MR elastography with a gradient-recalled-echo pulse sequence was low at 1.5 T but substantially higher at 3.0 T. Massive ascites, iron deposition, and high body mass index were additional independent factors associated with failure of MR elastography of the liver with a two-dimensional gradient-recalled-echo pulse sequence. © RSNA, 2017.

  9. Single Large Impacts and their Consequences on the Evolution of a Coupled Atmosphere-Interior Venus Model

    Science.gov (United States)

    Gillmann, C.; Golabek, G.; Tackley, P.

    2015-12-01

    We investigate the effect of a single large impact during the Late Veneer and Late Heavy Bombardment on the evolution of the mantle and atmosphere of Venus. We use a coupled interior/exterior numerical code based on StagYY and developed in Gillmann and Tackley [2014]. Single vertical impacts are simulated as instantaneous events affecting both the atmosphere and mantle of the planet by (i) eroding the atmosphere, causing atmospheric escape, and (ii) depositing energy in the crust and mantle of the planet. Main impactor parameters include timing, size/mass, velocity and efficiency of energy deposition. We observe that volatile delivery by the impactor and impact erosion of the atmosphere are both minor effects compared to melting and degassing triggered by the energy deposited in the mantle and crust. Small collisions (under 100 km radius) have only local and time-limited effects. Medium-sized impactors (100-300 km) will not have much more consequences unless the energy deposition is enhanced, for example by a fast collision. In that case, it will have comparable effects to the larger category of impacts (400-800 km): a strong thermal anomaly affecting both crust and mantle and triggering melting and a change in mantle dynamics patterns. Such an impact is a global event and can be responsible for volcanic events focused at the impact location and near the antipode. Depending on the timing of the impact, it can also have major consequences on the long-term evolution of the planet and its surface conditions by either (i) efficiently depleting the upper mantle of the planet, leading to the early loss of its water or (ii) imposing a volatile rich and hot atmosphere for billions of years. Due to the coupled nature of the evolution, both cases can affect the evolution of the whole planet (atmosphere and interior) on the long term.

  10. Quantifying the Impact of Immediate Reconstruction in Postmastectomy Radiation: A Large, Dose-Volume Histogram-Based Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ohri, Nisha [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Cordeiro, Peter G. [Department of Plastic Surgery, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Keam, Jennifer [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Ballangrud, Ase [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Shi Weiji; Zhang Zhigang [Department of Biostatistics and Epidemiology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Nerbun, Claire T.; Woch, Katherine M.; Stein, Nicholas F.; Zhou Ying [Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); McCormick, Beryl; Powell, Simon N. [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Ho, Alice Y., E-mail: HoA1234@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2012-10-01

    Purpose: To assess the impact of immediate breast reconstruction on postmastectomy radiation (PMRT) using dose-volume histogram (DVH) data. Methods and Materials: Two hundred forty-seven women underwent PMRT at our center, 196 with implant reconstruction and 51 without reconstruction. Patients with reconstruction were treated with tangential photons, and patients without reconstruction were treated with en-face electron fields and customized bolus. Twenty percent of patients received internal mammary node (IMN) treatment. The DVH data were compared between groups. Ipsilateral lung parameters included V20 (% volume receiving 20 Gy), V40 (% volume receiving 40 Gy), mean dose, and maximum dose. Heart parameters included V25 (% volume receiving 25 Gy), mean dose, and maximum dose. IMN coverage was assessed when applicable. Chest wall coverage was assessed in patients with reconstruction. Propensity-matched analysis adjusted for potential confounders of laterality and IMN treatment. Results: Reconstruction was associated with lower lung V20, mean dose, and maximum dose compared with no reconstruction (all P<.0001). These associations persisted on propensity-matched analysis (all P<.0001). Heart doses were similar between groups (P=NS). Ninety percent of patients with reconstruction had excellent chest wall coverage (D95 >98%). IMN coverage was superior in patients with reconstruction (D95 >92.0 vs 75.7%, P<.001). IMN treatment significantly increased lung and heart parameters in patients with reconstruction (all P<.05) but minimally affected those without reconstruction (all P>.05). Among IMN-treated patients, only lower lung V20 in those without reconstruction persisted (P=.022), and mean and maximum heart doses were higher than in patients without reconstruction (P=.006, P=.015, respectively). Conclusions: Implant reconstruction does not compromise the technical quality of PMRT when the IMNs are untreated. Treatment technique, not reconstruction, is the primary

  11. Genetic influences on schizophrenia and subcortical brain volumes: large-scale proof-of-concept and roadmap for future studies

    OpenAIRE

    Franke, Barbara; Stein, Jason L; Ripke, Stephan; Anttila, Verneri; Hibar, Derrek P; van Hulzen, Kimm J E; Arias-Vasquez, Alejandro; Smoller, Jordan W; Nichols, Thomas E; Neale, Michael C; McIntosh, Andrew M; Lee, Phil; McMahon, Francis J; Meyer-Lindenberg, Andreas; Mattheisen, Manuel

    2016-01-01

    Schizophrenia is a devastating psychiatric illness with high heritability. Brain structure and function differ, on average, between people with schizophrenia and healthy individuals. As common genetic associations are emerging for both schizophrenia and brain imaging phenotypes, we can now use genome-wide data to investigate genetic overlap. Here we integrated results from common variant studies of schizophrenia (33,636 cases, 43,008 controls) and volumes of several (mainly subcortical) brain...

  12. Benchmarking of depth of field for large out-of-plane deformations with single camera digital image correlation

    Science.gov (United States)

    Van Mieghem, Bart; Ivens, Jan; Van Bael, Albert

    2017-04-01

    A problem that arises when performing stereo digital image correlation in applications with large out-of-plane displacements is that the images may become unfocused. This unfocusing could result in correlation instabilities or inaccuracies. When performing DIC measurements and expecting large out-of-plane displacements researchers either trust on their experience or use the equations from photography to estimate the parameters affecting the depth of field (DOF) of the camera. A limitation of the latter approach is that the definition of sharpness is a human defined parameter and that it does not reflect the performance of the digital image correlation system. To get a more representative DOF value for DIC applications, a standardised testing method is presented here, making use of real camera and lens combinations as well as actual image correlation results. The method is based on experimental single camera DIC measurements of a backwards moving target. Correlation results from focused and unfocused images are compared and a threshold value defines whether or not the correlation results are acceptable even if the images are (slightly) unfocused. By following the proposed approach, the complete DOF of a specific camera/lens combination as function of the aperture setting and distance from the camera to the target can be defined. The comparison between the theoretical and the experimental DOF results shows that the achievable DOF for DIC applications is larger than what theoretical calculations predict. Practically this means that the cameras can be positioned closer to the target than what is expected from the theoretical approach. This leads to a gain in resolution and measurement accuracy.

  13. Association between hospital procedure volume and early complications after pacemaker implantation: results from a large, unselected, contemporary cohort of the German nationwide obligatory external quality assurance programme.

    Science.gov (United States)

    Nowak, Bernd; Tasche, Karl; Barnewold, Linda; Heller, Günther; Schmidt, Boris; Bordignon, Stefano; Chun, K R Julian; Fürnkranz, Alexander; Mehta, Rajendra H

    2015-05-01

    Several studies demonstrated an inverse relationship between cardioverter-defibrillator implantation volume and complication rates, suggesting better outcomes for higher volume centres. However, the association of institutional procedural volume with patient outcomes for permanent pacemaker (PPM) implantation remains less known, especially in decentralized implantation systems. We performed retrospective examination of data on patients undergoing PPM from the German obligatory quality assurance programme (2007-12) to evaluate the relationship of hospital PPM volume (categorized into quintiles of their mean annual volume) with risk-adjusted in-hospital surgical complications (composite of pneumothorax, haemothorax, pericardial effusion, or pocket haematoma, all requiring intervention, or device infection) and pacemaker lead dislocation. Overall 430 416 PPM implantations were documented in 1226 hospitals. Systems included dual (72.8%) and single (25.8%) chamber PPM and cardiac resynchronization therapy (CRT) devices (1.1%). Complications included surgical (0.92%), and ventricular (0.99%), and atrial (1.22%) lead dislocation. Despite an increase in relatively complex procedures (dual chamber, CRT), there was a significant decrease in the procedural and fluoroscopy times and complications from lowest to highest implantation volume quintiles (P for trend <0.0001). The greatest difference was observed between the lowest (1-50 implantations/year-reference group) and the second-lowest (51-90 implantations/year) quintile: surgical complications [odds ratio (OR) 0.69; confidence interval (CI) 0.60-0.78], atrial lead dislocations (OR 0.69; CI 0.59-0.80), and ventricular lead dislocations (OR 0.73; CI 0.63-0.84). Hospital annual PPM volume was directly related to indication-based implantation of relatively more complex PPM and yet inversely with procedural times and rates of early surgical complications and lead dislocations. Thus, our data suggest better performance and lower

  14. Low volume, large force (>1mN) and nanometer resolution, electrostatic microactuator for low displacement applications

    NARCIS (Netherlands)

    Sarajlic, Edin; Berenschot, Johan W.; Krijnen, Gijsbertus J.M.; Elwenspoek, Michael Curt

    2003-01-01

    A compact electrostatic microactuator suitable for low displacement applications is proposed. The actuator employs a large number of basic units working in parallel together with a built-in mechanical transformation to generate large force. Influence of distinct design parameters on actuator

  15. Experimental synchronization of chaos in a large ring of mutually coupled single-transistor oscillators: Phase, amplitude, and clustering effects

    Science.gov (United States)

    Minati, Ludovico

    2014-12-01

    In this paper, experimental evidence of multiple synchronization phenomena in a large (n = 30) ring of chaotic oscillators is presented. Each node consists of an elementary circuit, generating spikes of irregular amplitude and comprising one bipolar junction transistor, one capacitor, two inductors, and one biasing resistor. The nodes are mutually coupled to their neighbours via additional variable resistors. As coupling resistance is decreased, phase synchronization followed by complete synchronization is observed, and onset of synchronization is associated with partial synchronization, i.e., emergence of communities (clusters). While component tolerances affect community structure, the general synchronization properties are maintained across three prototypes and in numerical simulations. The clusters are destroyed by adding long distance connections with distant notes, but are otherwise relatively stable with respect to structural connectivity changes. The study provides evidence that several fundamental synchronization phenomena can be reliably observed in a network of elementary single-transistor oscillators, demonstrating their generative potential and opening way to potential applications of this undemanding setup in experimental modelling of the relationship between network structure, synchronization, and dynamical properties.

  16. ClariVein® - Early results from a large single-centre series of mechanochemical endovenous ablation for varicose veins.

    Science.gov (United States)

    Tang, T Y; Kam, J W; Gaunt, M E

    2017-02-01

    Objectives This study assessed the effectiveness and patient experience of the ClariVein® endovenous occlusion catheter for varicose veins from a large single-centre series in the UK. Methods A total of 300 patients (371 legs) underwent ClariVein® treatment for their varicose veins; 184 for great saphenous vein (GSV) incompetence, 62 bilateral GSV, 23 short saphenous vein (SSV), 6 bilateral SSV and 25 combined unilateral great saphenous vein and SSV. Patients were reviewed at an interval of two months post procedure and underwent Duplex ultrasound assessment. Postoperative complications were recorded along with patient satisfaction. Results All 393 procedures were completed successfully under local anaesthetic. Complete occlusion of the treated vein was initially achieved in all the patients, but at eight weeks' follow-up, there was only partial obliteration in 13/393 (3.3%) veins. These were all successfully treated with ultrasound-guided foam sclerotherapy. Procedures were well tolerated with a mean pain score of 0.8 (0-10). No significant complications were reported. Conclusions ClariVein® can be used to ablate long and short saphenous varicose veins on a walk-in-walk-out basis. Bilateral procedures can be successfully performed, and these are well tolerated as can multiple veins in the same leg. Early results are promising but further evaluation and longer term follow-up are required.

  17. Dosimetric effect of multileaf collimator leaf width in intensity-modulated radiotherapy delivery techniques for small- and large-volume targets

    International Nuclear Information System (INIS)

    Yoganathan, S.A.; Mani, Karthick Raj; Maria Das, K.J.; Agarwal, Arpita; Kumar, Shaleen

    2011-01-01

    The purpose of this study was to evaluate the dosimetric effect of the leaf width of a multileaf collimator (MLC) in intensity-modulated radiotherapy (IMRT) delivery techniques for small- and large-volume targets. We retrospectively selected previously treated 5 intracranial and 5 head-neck patients for this study to represent small- (range, 18.37-72.75 cc; mean, 42.99 cc) and large-volume (range, 312.31-472.84 cc; mean, 361.14 cc) targets. A 6-MV photon beam data was configured for Brianlab m3 (3 mm), Varian Millennium 120 (5 mm) and Millennium 80 (10 mm) MLCs in the Eclipse treatment-planning system. Sliding window and step-shoot IMRT plans were generated for intracranial patients using all the above-mentioned MLCs; but due to the field size limitation of Brainlab MLC, we used only 5-mm and 10-mm MLCs in the head-and-neck patients. Target conformity, dose to the critical organs and dose to normal tissues were recorded and evaluated. Although the 3-mm MLC resulted in better target conformity (mean difference of 7.7% over 5-mm MLC and 12.7% over 10-mm MLC) over other MLCs for small-volume targets, it increased the total monitor units of the plans. No appreciable differences in terms of target conformity, organ at risk and normal-tissue sparing were observed between the 5-mm and 10-mm MLCs for large-volume targets. The effect of MLC leaf width was not quantifiably different in sliding window and step and shoot techniques. In addition, we observed that there was no additional benefit to the sliding-window (SW) technique when compared to the step-shoot (SS) technique as a result of reduction of MLC leaf width. (author)

  18. Containment at the Source during Waste Volume Reduction of Large Radioactive Components Using Oxylance High-Temperature Cutting Equipment - 13595

    International Nuclear Information System (INIS)

    Keeney, G. Neil

    2013-01-01

    As a waste-volume reduction and management technique, highly contaminated Control Element Drive Mechanism (CEDM) housings were severed from the Reactor Pressure Vessel Head (RPVH) inside the San Onofre Unit 2 primary containment utilizing Oxylance high-temperature cutting equipment and techniques. Presented are relevant data concerning: - Radiological profiles of the RPVH and individual CEDMs; - Design overviews of the engineering controls and the specialized confinement housings; - Utilization of specialized shielding; - Observations of apparent metallurgical-contamination coalescence phenomena at high temperatures resulting in positive control over loose-surface contamination conditions; - General results of radiological and industrial hygiene air sampling and monitoring; - Collective dose and personnel contamination event statistics; - Lessons learned. (author)

  19. Best single-slice location to measure visceral adipose tissue on paediatric CT scans and the relationship between anthropometric measurements, gender and VAT volume in children.

    Science.gov (United States)

    O'Connor, Michelle; Ryan, John; Foley, Shane

    2015-10-01

    Visceral adipose tissue (VAT) is a significant risk factor for obesity-related metabolic diseases. This study investigates (1) the best single CT slice location for predicting total abdominal VAT volume in paediatrics and (2) the relationship between waist circumference (WC), sagittal diameter (SD), gender and VAT volume. A random sample of 130 paediatric abdomen CT scans, stratified according to age and gender, was collected. Three readers measured VAT area at each intervertebral level between T12 and S1 using ImageJ analysis (National Institute of Health, Bethesda, MD) software by thresholding -190 to -30 HU and manually segmenting VAT. Single-slice VAT measurements were correlated with total VAT volume to identify the most representative slice. WC and SD were measured at L3-L4 and L4-L5 slices, respectively. Regression analysis was used to evaluate WC, SD and gender as VAT volume predictors. Interviewer and intraviewer reliability were excellent (intraclass correlation coefficient = 0.99). Although VAT measured at multiple slices correlated strongly with abdominal VAT, only one slice in females at L2-L3 and two slices in males at L1-L2 and L5-S1 were strongly correlated across all age groups. Linear regression analysis showed that WC was strongly correlated with VAT volume (beta = 0.970, p VAT measurements are highly reproducible. Measurements performed at L2-L3 in females and L1-L2 or L5-S1 in males were most representative of VAT. WC is indicative of VAT. VAT should be measured at L2-L3 in female children and at either L1-L2 or L5-S1 in males. WC is a strong indicator of VAT in children.

  20. Effects of artificial holes in very large single-grain Y{sub 1.5}Ba{sub 2}Cu{sub 3}O{sub 7-y} bulk superconductors

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. D.; Jun, B. H.; Kim, C. J. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Park, H. W. [Korea University of Technology and Education, Cheonan (Korea, Republic of)

    2017-09-15

    The effects of artificial holes on the trapped magnetic fields and magnetic levitation forces of very large single-grain Y{sub 1.5}Ba{sub 2}Cu{sub 3}O{sub 7-y} (Y1.5) bulk superconductors were studied. Artificial holes were made for Y1.5 powder compacts by die pressing using cylindrical dies with a diameter of 30 mm or 40 m, or rectangular dies with a side length of 50 mm. The single grain Y1.5 bulk superconductors (25 mm, 33 mm in diameter and 42 mm in side length) with artificial holes were fabricated using a top-seeded melt growth (TSMG) process for the die-pressed Y1.5 powder compacts. The magnetic levitation forces at 77 K of the 25 mm single grain Y1.5 samples with one (diameters of 4.2 mm) or six artificial holes (diameters of 2.5 mm) were 10-17% higher than that of the Y1.5 sample without artificial holes. The trapped magnetic fields at 77 K of the Y1.5 samples with artificial holes were also 9.6-18% higher than that of the Y1.5 sample without artificial holes. The 33 mm and 42 mm single grain Y1.5 samples with artificial holes (2.5 mm and 4.2 mm in diameter) also showed trapped magnetic fields 10-13% higher than that of the Y1.5 samples without artificial holes in spite of the reduced superconducting volume fraction due to the presence of artificial holes. The property enhancement in the large single grain Y1.5 bulk superconductors appears to be attributed to the formation of the pore-free regions near the artificial holes and the homogeneous oxygen distribution in the large Y123 grains.

  1. MIDAS prototype Multispectral Interactive Digital Analysis System for large area earth resources surveys. Volume 2: Charge coupled device investigation

    Science.gov (United States)

    Kriegler, F.; Marshall, R.; Sternberg, S.

    1976-01-01

    MIDAS is a third-generation, fast, low cost, multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from large regions with present and projected sensors. MIDAS, for example, can process a complete ERTS frame in forty seconds and provide a color map of sixteen constituent categories in a few minutes. A principal objective of the MIDAS Program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughput. The need for advanced onboard spacecraft processing of remotely sensed data is stated and approaches to this problem are described which are feasible through the use of charge coupled devices. Tentative mechanizations for the required processing operations are given in large block form. These initial designs can serve as a guide to circuit/system designers.

  2. Large-scale single-crystal growth of (CH3)2NH2CuCl3 for neutron scattering experiments

    Science.gov (United States)

    Park, Garam; Oh, In-Hwan; Park, J. M. Sungil; Park, Seong-Hun; Hong, Chang Seop; Lee, Kwang-Sei

    2016-05-01

    Neutron scattering studies on low-dimensional quantum spin systems require large-size single-crystals. Single-crystals of (CH3)2NH2CuCl3 showing low-dimensional magnetic behaviors were grown by a slow solvent evaporation method in a two-solvent system at different temperature settings. The best results were obtained for the bilayer solution of methanol and isopropanol with a molar ratio of 2:1 at 35 °C. The quality of the obtained single-crystals was tested by powder and single-crystal X-ray diffraction and single-crystal neutron diffraction. In addition, to confirm structural phase transitions (SPTs), thermal analysis and single-crystal X-ray diffraction at 300 K and 175 K, respectively, were conducted, confirming the presence of a SPT at Tup=288 K on heating and Tdown=285 K on cooling.

  3. Robust semi-automatic segmentation of single- and multichannel MRI volumes through adaptable class-specific representation

    Science.gov (United States)

    Nielsen, Casper F.; Passmore, Peter J.

    2002-05-01

    Segmentation of MRI volumes is complicated by noise, inhomogeneity and partial volume artefacts. Fully or semi-automatic methods often require time consuming or unintuitive initialization. Adaptable Class-Specific Representation (ACSR) is a semi-automatic segmentation framework implemented by the Path Growing Algorithm (PGA), which reduces artefacts near segment boundaries. The user visually defines the desired segment classes through the selection of class templates and the following segmentation process is fully automatic. Good results have previously been achieved with color cryo section segmentation and ACSR has been developed further for the MRI modality. In this paper we present two optimizations for robust ACSR segmentation of MRI volumes. Automatic template creation based on an initial segmentation step using Learning Vector Quantization is applied for higher robustness to noise. Inhomogeneity correction is added as a pre-processing step, comparing the EQ and N3 algorithms. Results based on simulated T1-weighed and multispectral (T1 and T2) MRI data from the BrainWeb database and real data from the Internet Brain Segmentation Repository are presented. We show that ACSR segmentation compares favorably to previously published results on the same volumes and discuss the pros and cons of using quantitative ground truth evaluation compared to qualitative visual assessment.

  4. Comparison of the effect of a single dose of erythromycin with pantoprazole on gastric content volume and acidity in elective general surgery patients

    Directory of Open Access Journals (Sweden)

    Nidhi Bhatia

    2011-01-01

    Full Text Available Introduction: Pulmonary aspiration of gastric contents remains one of the most feared complications of anesthesia. A gastric pH of 2.5 or less and a volume of 25 ml (0.4 ml/kg body weight or more in average adult patients are considered critical factors for the development of pulmonary damage in adults. Materials and Methods: This study compared the efficacy of a single oral dose of erythromycin (a macrolide antibiotic with oral pantoprazole (a proton pump inhibitor on pre-operative gastric fluid volume and pH in a prospective, randomized, double-blind controlled fashion in 80 adult patients (of ASA physical status I and II planned for elective surgery under general anesthesia. Patients were divided into two groups of 40 patients each. The pantoprazole group (Group I received oral pantoprazole 40 mg and the erythromycin group (Group II received oral erythromycin 250 mg at least 1 h prior to the induction of anesthesia. After tracheal intubation, gastric fluid was aspirated via a Salem Sump tube and its volume and pH were measured. Results: Although both erythromycin and pantoprazole decreased the gastric fluid volume to a similar extent, the decrease in gastric fluid acidity by pantoprazole was significantly greater than that by erythromycin. The proportion of patients at risk of pulmonary aspiration according to traditional criteria, i.e. pH ≤2.5 and volume ≥25ml, was lower in the pantoprazole group. Conclusion: Administration of pantoprazole was found to be more useful than a sub-therapeutic dose of erythromycin in decreasing both volume and acidity of gastric content.

  5. Increased single-balloon Foley catheter volume for induction of labor and time to delivery: a systematic review and meta-analysis.

    Science.gov (United States)

    Schoen, Corina N; Saccone, Gabriele; Backley, Sami; Sandberg, Evelien M; Gu, Ning; Delaney, Shani; Berghella, Vincenzo

    2018-04-01

    Induction of labor is a common intervention. The objective was to investigate whether larger Foley catheter volumes for labor induction decrease the total time from induction to delivery. Randomized controlled trials comparing larger single-balloon volumes (60-80 mL) during Foley catheter cervical ripening with usual volume (30 mL) in women undergoing labor induction were identified by searching electronic databases (MEDLINE, Scopus, ClinicalTrials. gov, PROSPERO, EMBASE, Scielo and the Cochrane Central Register of Controlled Trials) from inception through 2017. The primary outcome was mean time from induction to delivery in hours. Secondary outcomes included time from induction to vaginal delivery, delivery within 24 hours, time to Foley expulsion, cesarean section, chorioamnionitis, epidural use, hemorrhage, meconium staining, and neonatal intensive care unit admission. Meta-analysis was performed using the random effects model of DerSimonian and Laird. (PROSPERO CRD42017058885). Seven randomized controlled trials including 1,432 singleton gestations were included in the systematic review. Women randomized to larger volumes of balloon had a significantly shorter time from induction to delivery (mean difference 1.97 hours, 95% CI; -3.88 to -0.06). There was no difference in cesarean section between groups (16% vs. 18%, relative risk 0.84, CI; 0.6 to 1.17). A larger balloon volume was associated with a non-significant decrease in time from induction to delivery in multiparous (mean difference 2.67 hours, CI; -6.1 to 0.76) and nulliparous women (mean difference 1.82 hours, CI; -4.16 to 0.53). Balloon volumes larger than 30 mL during Foley catheter induction reduce total time to delivery by approximately two hours. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  6. Large Deployable Reflector (LDR) system concept and technology definition study. Volume 2: Technology assessment and technology development plan

    Science.gov (United States)

    Agnew, Donald L.; Jones, Peter A.

    1989-01-01

    A study was conducted to define reasonable and representative LDR system concepts for the purpose of defining a technology development program aimed at providing the requisite technological capability necessary to start LDR development by the end of 1991. This volume presents thirteen technology assessments and technology development plans, as well as an overview and summary of the LDR concepts. Twenty-two proposed augmentation projects are described (selected from more than 30 candidates). The five LDR technology areas most in need of supplementary support are: cryogenic cooling; astronaut assembly of the optically precise LDR in space; active segmented primary mirror; dynamic structural control; and primary mirror contamination control. Three broad, time-phased, five-year programs were synthesized from the 22 projects, scheduled, and funding requirements estimated.

  7. A novel optical microscope for imaging large embryos and tissue volumes with sub-cellular resolution throughout.

    Science.gov (United States)

    McConnell, Gail; Trägårdh, Johanna; Amor, Rumelo; Dempster, John; Reid, Es; Amos, William Bradshaw

    2016-09-23

    Current optical microscope objectives of low magnification have low numerical aperture and therefore have too little depth resolution and discrimination to perform well in confocal and nonlinear microscopy. This is a serious limitation in important areas, including the phenotypic screening of human genes in transgenic mice by study of embryos undergoing advanced organogenesis. We have built an optical lens system for 3D imaging of objects up to 6 mm wide and 3 mm thick with depth resolution of only a few microns instead of the tens of microns currently attained, allowing sub-cellular detail to be resolved throughout the volume. We present this lens, called the Mesolens, with performance data and images from biological specimens including confocal images of whole fixed and intact fluorescently-stained 12.5-day old mouse embryos.

  8. Dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with high-dose-rate brachytherapy for large prostate volumes

    Energy Technology Data Exchange (ETDEWEB)

    Yang, George; Strom, Tobin J.; Shrinath, Kushagra; Mellon, Eric A.; Fernandez, Daniel C.; Biagioli, Matthew C. [Department of Radiation Oncology, H. Lee Moffitt Cancer Center and Research Institute, Tampa, FL (United States); Wilder, Richard B., E-mail: mcbiagioli@yahoo.com [Cancer Treatment Centers of America, Newnan, GA (United States)

    2015-05-15

    Purpose: to evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes. Materials and methods: one hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL) were treated with high-dose-rate (HDR) brachytherapy ± intensity modulated radiation therapy (IMRT) to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38%) unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE) version 4. Results: median follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3%) patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17%) patients developed Grade 2 acute urinary retention. American Urological Association (AUA) symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p-0.04). There was no ≥ Grade 3 acute toxicity. Conclusions: dosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes. (author)

  9. Dosimetric Coverage of the Prostate, Normal Tissue Sparing, and Acute Toxicity with High-Dose-Rate Brachytherapy for Large Prostate Volumes

    Directory of Open Access Journals (Sweden)

    George Yang

    2015-06-01

    Full Text Available ABSTRACTPurposeTo evaluate dosimetric coverage of the prostate, normal tissue sparing, and acute toxicity with HDR brachytherapy for large prostate volumes.Materials and MethodsOne hundred and two prostate cancer patients with prostate volumes >50 mL (range: 5-29 mL were treated with high-dose-rate (HDR brachytherapy ± intensity modulated radiation therapy (IMRT to 4,500 cGy in 25 daily fractions between 2009 and 2013. HDR brachytherapy monotherapy doses consisted of two 1,350-1,400 cGy fractions separated by 2-3 weeks, and HDR brachytherapy boost doses consisted of two 950-1,150 cGy fractions separated by 4 weeks. Twelve of 32 (38% unfavorable intermediate risk, high risk, and very high risk patients received androgen deprivation therapy. Acute toxicity was graded according to the Common Terminology Criteria for Adverse Events (CTCAE version 4.ResultsMedian follow-up was 14 months. Dosimetric goals were achieved in over 90% of cases. Three of 102 (3% patients developed Grade 2 acute proctitis. No variables were significantly associated with Grade 2 acute proctitis. Seventeen of 102 (17% patients developed Grade 2 acute urinary retention. American Urological Association (AUA symptom score was the only variable significantly associated with Grade 2 acute urinary retention (p=0.04. There was no ≥ Grade 3 acute toxicity.ConclusionsDosimetric coverage of the prostate and normal tissue sparing were adequate in patients with prostate volumes >50 mL. Higher pre-treatment AUA symptom scores increased the relative risk of Grade 2 acute urinary retention. However, the overall incidence of acute toxicity was acceptable in patients with large prostate volumes.

  10. The visualization of large organized chromatin domains enriched in the H3K9me2 mark within a single chromosome in a single cell

    NARCIS (Netherlands)

    Chen, X.; Yammine, S.; Shi, C.; Tark-Dame, M.; Göndör, A.; Ohlsson, R.

    2014-01-01

    Despite considerable efforts, our understanding of the organization of higher order chromatin conformations in single cells and how these relate to chromatin marks remains poor. We have earlier invented the Chromatin In Situ Proximity (ChrISP) technique to determine proximities between chromatin

  11. The Limits and Possibilities of International Large-Scale Assessments. Education Policy Brief. Volume 9, Number 2, Spring 2011

    Science.gov (United States)

    Rutkowski, David J.; Prusinski, Ellen L.

    2011-01-01

    The staff of the Center for Evaluation & Education Policy (CEEP) at Indiana University is often asked about how international large-scale assessments influence U.S. educational policy. This policy brief is designed to provide answers to some of the most frequently asked questions encountered by CEEP researchers concerning the three most popular…

  12. Combination of large volume sample stacking and reversed pH junction in capillary electrophoresis for online preconcentration of glycoforms of recombinant human erythropoietin.

    Science.gov (United States)

    Liu, Jing; Liu, Zhen; Kang, Mingchao; Liu, Sichang; Chen, Hong-Yuan

    2009-02-01

    Resolution of glycoforms of a glycoprotein is usually a challenge for an analytical chemist, which is often associated with the difficulty of detecting a large number of glycoforms with sufficient sensitivity. CE is the main workhorse for the analysis of glycoproteins; however, the current methods are only applicable to high concentration samples. Therefore, the development of online preconcentration approaches is important for the CE analysis of glycoproteins. In this study, we present a combined strategy for online preconcentrating glycoforms of glycoproteins, which couples two individual online preconcentration techniques, i.e., large volume sample stacking (LVSS) and reversed pH junction (RPHJ). LVSS allows for compressing a large injected sample volume into a narrow sample zone, contributing to the main sensitivity improvement, while RPHJ coordinates the preconcentration process to improve the resolution. This strategy was verified with recombinant human erythropoietin (rhEPO), a typical glycoprotein, as the test analyte, and the effects of experimental conditions were investigated. It was found that there is a compromise between sensitivity enhancement and resolution for online preconcentration of glycoprotein glycoforms. By using this strategy, the detection sensitivity can be improved by 50-100 times for rhEPO.

  13. Low tidal volume ventilation use remains low in patients with acute respiratory distress syndrome at a single center.

    Science.gov (United States)

    Spece, Laura J; Mitchell, Kristina H; Caldwell, Ellen S; Gundel, Stephanie J; Jolley, Sarah E; Hough, Catherine L

    2018-04-01

    Low tidal volume ventilation (LTVV) reduces mortality in acute respiratory distress syndrome (ARDS) patients. Understanding local barriers to LTVV use at a former ARDS Network hospital may provide new insight to improve LTVV implementation. A cohort of 214 randomly selected adults met the Berlin definition of ARDS at Harborview Medical Center between 2008 and 2012. The primary outcome was the receipt of LTVV (tidal volume of ≤6.5mL/kg predicted body weight) within 48h of ARDS onset. We constructed a multivariable logistic regression model to identify factors associated with the outcome. Only 27% of patients received tidal volumes of ≤6.5mL/kg PBW within 48h of ARDS onset. Increasing plateau pressure (OR 1.11; 95% CI 1.03 to 1.19; p-value<0.01) was positively associated with LTVV use while increasing PaO 2 :F I O 2 ratio was negatively associated (OR 0.75; 95% CI 0.57 to 0.98; p-value 0.03). Physicians documented an ARDS diagnosis in only 21% of the cohort. Neither patient height nor gender was associated with LTVV use. Most ARDS patients did not receive LTVV despite implementation of a protocol. ARDS was also recognized in a minority of patients, suggesting an opportunity for improvement of care. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Single minimum incision endoscopic radical nephrectomy for renal tumors with preoperative virtual navigation using 3D-CT volume-rendering

    Directory of Open Access Journals (Sweden)

    Shioyama Yasukazu

    2010-04-01

    Full Text Available Abstract Background Single minimum incision endoscopic surgery (MIES involves the use of a flexible high-definition laparoscope to facilitate open surgery. We reviewed our method of radical nephrectomy for renal tumors, which is single MIES combined with preoperative virtual surgery employing three-dimensional CT images reconstructed by the volume rendering method (3D-CT images in order to safely and appropriately approach the renal hilar vessels. We also assessed the usefulness of 3D-CT images. Methods Radical nephrectomy was done by single MIES via the translumbar approach in 80 consecutive patients. We performed the initial 20 MIES nephrectomies without preoperative 3D-CT images and the subsequent 60 MIES nephrectomies with preoperative 3D-CT images for evaluation of the renal hilar vessels and the relation of each tumor to the surrounding structures. On the basis of the 3D information, preoperative virtual surgery was performed with a computer. Results Single MIES nephrectomy was successful in all patients. In the 60 patients who underwent 3D-CT, the number of renal arteries and veins corresponded exactly with the preoperative 3D-CT data (100% sensitivity and 100% specificity. These 60 nephrectomies were completed with a shorter operating time and smaller blood loss than the initial 20 nephrectomies. Conclusions Single MIES radical nephrectomy combined with 3D-CT and virtual surgery achieved a shorter operating time and less blood loss, possibly due to safer and easier handling of the renal hilar vessels.

  15. Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

    Energy Technology Data Exchange (ETDEWEB)

    Knybel, Lukas [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic); VŠB-Technical University of Ostrava, Ostrava (Czech Republic); Cvek, Jakub, E-mail: Jakub.cvek@fno.cz [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic); Molenda, Lukas; Stieberova, Natalie; Feltl, David [Department of Oncology, University Hospital Ostrava, Ostrava (Czech Republic)

    2016-11-15

    Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P<.001). Motion amplitudes >15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P<.001). Interfraction variations and baseline changes >3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe

  16. Analysis of Lung Tumor Motion in a Large Sample: Patterns and Factors Influencing Precise Delineation of Internal Target Volume

    International Nuclear Information System (INIS)

    Knybel, Lukas; Cvek, Jakub; Molenda, Lukas; Stieberova, Natalie; Feltl, David

    2016-01-01

    Purpose/Objective: To evaluate lung tumor motion during respiration and to describe factors affecting the range and variability of motion in patients treated with stereotactic ablative radiation therapy. Methods and Materials: Log file analysis from online respiratory tumor tracking was performed in 145 patients. Geometric tumor location in the lungs, tumor volume and origin (primary or metastatic), sex, and tumor motion amplitudes in the superior-inferior (SI), latero-lateral (LL), and anterior-posterior (AP) directions were recorded. Tumor motion variability during treatment was described using intrafraction/interfraction amplitude variability and tumor motion baseline changes. Tumor movement dependent on the tumor volume, position and origin, and sex were evaluated using statistical regression and correlation analysis. Results: After analysis of >500 hours of data, the highest rates of motion amplitudes, intrafraction/interfraction variation, and tumor baseline changes were in the SI direction (6.0 ± 2.2 mm, 2.2 ± 1.8 mm, 1.1 ± 0.9 mm, and −0.1 ± 2.6 mm). The mean motion amplitudes in the lower/upper geometric halves of the lungs were significantly different (P<.001). Motion amplitudes >15 mm were observed only in the lower geometric quarter of the lungs. Higher tumor motion amplitudes generated higher intrafraction variations (R=.86, P<.001). Interfraction variations and baseline changes >3 mm indicated tumors contacting mediastinal structures or parietal pleura. On univariate analysis, neither sex nor tumor origin (primary vs metastatic) was an independent predictive factor of different movement patterns. Metastatic lesions in women, but not men, showed significantly higher mean amplitudes (P=.03) and variability (primary, 2.7 mm; metastatic, 4.9 mm; P=.002) than primary tumors. Conclusion: Online tracking showed significant irregularities in lung tumor movement during respiration. Motion amplitude was significantly lower in upper lobe

  17. 'Dip-sticks' calibration handles self-attenuation and coincidence effects in large-volume gamma-ray spectrometry

    CERN Document Server

    Wolterbeek, H T

    2000-01-01

    Routine gamma-spectrometric analyses of samples with low-level activities (e.g. food, water, environmental and industrial samples) are often performed in large samples, placed close to the detector. In these geometries, detection sensitivity is improved but large errors are introduced due to self-attenuation and coincidence summing. Current approaches to these problems comprise computational methods and spiked standard materials. However, the first are often regarded as too complex for practical routine use, the latter never fully match real samples. In the present study, we introduce a dip-sticks calibration as a fast and easy practical solution to this quantification problem in a routine analytical setting. In the proposed set-up, calibrations are performed within the sample itself, thus making it a broadly accessible matching-reference approach, which is principally usable for all sample matrices.

  18. System of large transport containers for waste from dismantling light water and gas-cooled nuclear reactors. Volume 2

    International Nuclear Information System (INIS)

    Price, M.S.T.

    1986-09-01

    This report deals with the operational, radiological and economic aspects of transport as well as conceptual designs of large containers for the transport of radioactive decommissioning wastes from nuclear power plants within the member states of the European Economic Community. The means of transport, the costs and radiological detriment are considered, and conceptual designs of containers are described. Recommendations are made for further studies. (U.K.)

  19. Relevance of the volume-axis intercept, V0, compared with the slope of end-systolic pressure-volume relationship in response to large variations in inotropy and afterload in rats.

    Science.gov (United States)

    Blaudszun, Grégoire; Morel, Denis R

    2011-11-01

    The end-systolic pressure-volume relationship (ESPVR) is proposed and used as a reliable index of left ventricular (LV) contractility despite the fact that its afterload independence has been challenged. Furthermore, the physiological relevance of its volume-axis intercept, V(0), remains unclear. Systemic haemodynamics and pressure-volume loops obtained by inferior vena cava occlusion were recorded in 21 rats anaesthetized by isoflurane inhalation and instrumented with a conductance pressure-volume catheter in response to incremental I.V. doses of adrenaline, dobutamine, phenylephrine, metoprolol, papaverine and isoflurane inhalation. In conditions with large variations (± 100%) of both inotropy and afterload, infusion of negative inotropic drugs was associated with a dose-dependent rightward shift of ESPVR accompanied by a decrease in its slope (end-systolic elastance, E(es)), whereas positive inotropic agents produced an isolated decrease in V(0). With the predominant vasoactive drugs, there was a dose-dependent change in E(es) without major horizontal shifts, demonstrating that this slope mainly represents LV afterload rather than inotropy. When contractility was altered, V(0) was negatively correlated to the preload-adjusted contractility index, PAdP/dt(max), demonstrating that a reduced V(0) provides a good reflection of increased LV contractility. From these results, we computed a logarithmically adjusted E(es)/V(0) ratio, which resulted in reasonably strong concordance with PAdP/dt(max), including all the investigated drugs and dosages [n = 288; bias, 0.8 ± 16.2% (SD)]. Concordance with E(es) (bias, 7.2 ± 58.7%) or V(0) (bias, -0.6 ± 33.4%), used alone or with other commonly used contractility indices, was far less significant. In contrast to E(es), V(0) provides a relatively good LV contractility index because it is much less sensitive to afterload.

  20. Neutron multicounter detector for investigation of content and spatial distribution of fission materials in large volume samples

    International Nuclear Information System (INIS)

    Swiderska-Kowalczyk, M.; Starosta, W.; Zoltowski, T.

    1998-01-01

    The experimental device is a neutron coincidence well counter. It can be applied for passive assay of fissile - especially for plutonium bearing - materials. It consist of a set of 3 He tubes placed inside a polyethylene moderator; outputs from the tubes, first processed by preamplifier/amplifier/discriminator circuits, are then analysed using neutron correlator connected with a PC, and correlation techniques implemented in software. Such a neutron counter allows for determination of plutonium mass ( 240 Pu effective mass) in nonmultiplying samples having fairly big volume (up to 0.14 m 3 ). For determination of neutron sources distribution inside the sample, the heuristic methods based on hierarchical cluster analysis are applied. As an input parameters, amplitudes and phases of two-dimensional Fourier transformation of the count profiles matrices for known point sources distributions and for the examined samples, are taken. Such matrices are collected by means of sample scanning by detection head. During clustering process, counts profiles for unknown samples fitted into dendrograms using the 'proximity' criterion of the examined sample profile to standard samples profiles. Distribution of neutron sources in an examined sample is then evaluated on the basis of comparison with standard sources distributions. (author)

  1. A numerical investigation of three-dimensional flows in large volumes in the context of passive containment cooling in BWRs

    International Nuclear Information System (INIS)

    Smith, Brian L.

    2007-01-01

    The paper describes Computational Fluid Dynamics (CFD) calculations undertaken in support of analyses of three-dimensional flows that take place in the drywell volumes of advanced boiling water reactors with passive decay-heat removal systems. Data for comparison are taken from the 1/40th-scale European Simplified Boiling Water Reactor (ESBWR) mock-up facility PANDA under conditions of symmetric steam injection and asymmetric outflow. Steady-state simulations for pure steam conditions illustrate how the separate flow streams mix to ensure balanced outflow conditions to the condenser units. A transient calculation has also been performed to examine how air, assumed to be released from solution in the PANDA boiler, would ultimately accumulate in the separate condenser units. Results provide a possible explanation for the rundown in performance of one of the condensers, behaviour which was repeatedly observed in some of the earlier PANDA tests. The work also provides more general insights on how trace amounts of non-condensable gases may accumulate in passive cooling equipment

  2. Evaluation of left ventricular function and volume in patients with dilated cardiomyopathy: Gated myocardial single-photon emission tomography (SPECT) versus echocardiography

    International Nuclear Information System (INIS)

    Berk, Fatma; Isgoren, S.; Demir, H.; Kozdag, G.; Ural, D.; Komsuoglu, B.

    2005-01-01

    Left ventricular function, volumes and regional wall motion provide valuable diagnostic information and are of long-term prognostic importance in patients with dilated cardiomyopathy (DCM). This study was designed to compare the effectiveness of 2D-echocardiography and gated single-photon emission tomography (SPECT) for evaluation of these parameters in patients with DCM. Gated SPECT and 2D-echocardiography were performed in 33 patients having DCM. Gated SPECT data, including left ventricular ejection fraction (LVEF), were processed using an automated algorithm. Standard technique was used for 2D-echocardiography. Regional wall motion was evaluated using both modalities and was scored by two independent observers using a 16-sement model with a 5-point scoring system. The overall agreement between the two imaging modalities for the assessment of regional wall motion was 56% (298/528 segments). With gated SPECT, LEVF, end-diastolic volume (EDV), and end-diastolic volume (EDV), and end-systolic volume (ESV) were 27+-9%, 217+-73mL, respectively, and 30.8%, 195+-58mL and, 137+-48 mL with echocardiography. The correlation between gated SPECT and 2-D-echocardiography was good (r=0.76, P<0.01) for the assessment of LVEF. The correlation for EDV and ESV were also good, but with wider limits of agreement (r=0.72, P<0.01 and r=0.73, P<0.01, respectively) and significantly higher values were obtained with gated SPECT (P<0.01). Gated SPECT and 2D-echocardiography correlate well for the assessment of LV function and LV volumes. Like 2D-echocardiography, gated SPECT provides reliable information about LV function and dimension with the additional advantage of perfusion data. (author)

  3. Dynamics and evolution of the inverted repeat-large single copy junctions in the chloroplast genomes of monocots

    Directory of Open Access Journals (Sweden)

    Wu Chun-Lin

    2008-01-01

    Full Text Available Abstract Background Various expansions or contractions of inverted repeats (IRs in chloroplast genomes led to fluxes in the IR-LSC (large single copy junctions. Previous studies revealed that some monocot IRs contain a trnH-rps19 gene cluster, and it has been speculated that this may be an evidence of a duplication event prior to the divergence of monocot lineages. Therefore, we compared the organizations of genes flanking two IR-LSC junctions in 123 angiosperm representatives to uncover the evolutionary dynamics of IR-LSC junctions in basal angiosperms and monocots. Results The organizations of genes flanking IR-LSC junctions in angiosperms can be classified into three types. Generally each IR of monocots contains a trnH-rps19 gene cluster near the IR-LSC junctions, which differs from those in non-monocot angiosperms. Moreover, IRs expanded more progressively in monocots than in non-monocot angiosperms. IR-LSC junctions commonly occurred at polyA tract or A-rich regions in angiosperms. Our RT-PCR assays indicate that in monocot IRA the trnH-rps19 gene cluster is regulated by two opposing promoters, S10A and psbA. Conclusion Two hypotheses are proposed to account for the evolution of IR expansions in monocots. Based on our observations, the inclusion of a trnH-rps19 cluster in majority of monocot IRs could be reasonably explained by the hypothesis that a DSB event first occurred at IRB and led to the expansion of IRs to trnH, followed by a successive DSB event within IRA and lead to the expansion of IRs to rps19 or to rpl22 so far. This implies that the duplication of trnH-rps19 gene cluster was prior to the diversification of extant monocot lineages. The duplicated trnH genes in the IRB of most monocots and non-monocot angiosperms have distinct fates, which are likely regulated by different expression levels of S10A and S10B promoters. Further study is needed to unravel the evolutionary significance of IR expansion in more recently diverged

  4. Single-column model and large eddy simulation of the evening transition in the planetary boundary layer

    Science.gov (United States)

    Cuchiara, Gustavo; Rappenglück, Bernhard

    2016-04-01

    The transition from the convective boundary layer during the daytime to the stable stratified boundary layer during nighttime after sunset plays an important role in the transport and dispersion of atmospheric pollutants. However, our knowledge regarding this transition and its feedback on the structure of the subsequent nocturnal boundary layer is still restricted. This also prevents forecast models from accurate prediction of the onset and development of the nighttime boundary layer, which determines the redistribution of pollutants within the nocturnal surface layer and the residual layer aloft. In the present study, the well-known case of day 33 of the Wangara experiment is resimulated using the Weather Research and Forecasting (WRF) model in an idealized single-column mode to assess the performance of a frequently used planetary boundary layer (PBL) scheme, the Yonsei University (YSU) PBL scheme. These results are compared with two large eddy simulations (LES) for the same case study imposing different surface fluxes: one using previous surface fluxes calculated for the Wangara experiment and a second one using output from the WRF model. The results show a reasonable agreement of the PBL scheme in WRF with the LES. Overall, all the simulations presented a cold bias of ~3 Kelvin for the potential temperature and underestimation of the wind speed, especially after the transition to nighttime conditions (biases were up to 4 ms-1). Finally, an alternative set of eddy diffusivity equations was tested to represent the transition characteristics of a sunset period, with a stable layer below and a new parameterization for the convective decay regime typically observed in the RL aloft. This set of equations led to a gradual decrease of the eddy diffusivity, which replaces the instantaneous collapse of traditional diagnostics for eddy diffusivities. More appreciable changes were observed in air temperature, wind speed and specific humidity (up to 0.5 K, 0.6 ms-1, and 0

  5. An HTML5-Based Pure Website Solution for Rapidly Viewing and Processing Large-Scale 3D Medical Volume Reconstruction on Mobile Internet

    Directory of Open Access Journals (Sweden)

    Liang Qiao

    2017-01-01

    Full Text Available This study aimed to propose a pure web-based solution to serve users to access large-scale 3D medical volume anywhere with good user experience and complete details. A novel solution of the Master-Slave interaction mode was proposed, which absorbed advantages of remote volume rendering and surface rendering. On server side, we designed a message-responding mechanism to listen to interactive requests from clients (Slave model and to guide Master volume rendering. On client side, we used HTML5 to normalize user-interactive behaviors on Slave model and enhance the accuracy of behavior request and user-friendly experience. The results showed that more than four independent tasks (each with a data size of 249.4 MB could be simultaneously carried out with a 100-KBps client bandwidth (extreme test; the first loading time was <12 s, and the response time of each behavior request for final high quality image remained at approximately 1 s, while the peak value of bandwidth was <50-KBps. Meanwhile, the FPS value for each client was ≥40. This solution could serve the users by rapidly accessing the application via one URL hyperlink without special software and hardware requirement in a diversified network environment and could be easily integrated into other telemedical systems seamlessly.

  6. An HTML5-Based Pure Website Solution for Rapidly Viewing and Processing Large-Scale 3D Medical Volume Reconstruction on Mobile Internet.

    Science.gov (United States)

    Qiao, Liang; Chen, Xin; Zhang, Ye; Zhang, Jingna; Wu, Yi; Li, Ying; Mo, Xuemei; Chen, Wei; Xie, Bing; Qiu, Mingguo

    2017-01-01

    This study aimed to propose a pure web-based solution to serve users to access large-scale 3D medical volume anywhere with good user experience and complete details. A novel solution of the Master-Slave interaction mode was proposed, which absorbed advantages of remote volume rendering and surface rendering. On server side, we designed a message-responding mechanism to listen to interactive requests from clients ( Slave model) and to guide Master volume rendering. On client side, we used HTML5 to normalize user-interactive behaviors on Slave model and enhance the accuracy of behavior request and user-friendly experience. The results showed that more than four independent tasks (each with a data size of 249.4 MB) could be simultaneously carried out with a 100-KBps client bandwidth (extreme test); the first loading time was <12 s, and the response time of each behavior request for final high quality image remained at approximately 1 s, while the peak value of bandwidth was <50-KBps. Meanwhile, the FPS value for each client was ≥40. This solution could serve the users by rapidly accessing the application via one URL hyperlink without special software and hardware requirement in a diversified network environment and could be easily integrated into other telemedical systems seamlessly.

  7. Effect of NaOH on large-volume sample stacking of haloacetic acids in capillary zone electrophoresis with a low-pH buffer.

    Science.gov (United States)

    Tu, Chuanhong; Zhu, Lingyan; Ang, Chay Hoon; Lee, Hian Kee

    2003-06-01

    Large-volume sample stacking (LVSS) is an effective on-capillary sample concentration method in capillary zone electrophoresis, which can be applied to the sample in a low-conductivity matrix. NaOH solution is commonly used to back-extract acidic compounds from organic solvent in sample pretreatment. The effect of NaOH as sample matrix on LVSS of haloacetic acids was investigated in this study. It was found that the presence of NaOH in sample did not compromise, but rather help the sample stacking performance if a low pH background electrolyte (BGE) was used. The sensitivity enhancement factor was higher than the case when sample was dissolved in pure water or diluted BGE. Compared with conventional injection (0.4% capillary volume), 97-120-fold sensitivity enhancement in terms of peak height was obtained without deterioration of separation with an injection amount equal to 20% of the capillary volume. This method was applied to determine haloacetic acids in tap water by combination with liquid-liquid extraction and back-extraction into NaOH solution. Limits of detection at sub-ppb levels were obtained for real samples with direct UV detection.

  8. On Assumptions in Development of a Mathematical Model of Thermo-gravitational Convection in the Large Volume Process Tanks Taking into Account Fermentation

    Directory of Open Access Journals (Sweden)

    P. M. Shkapov

    2015-01-01

    Full Text Available The paper provides a mathematical model of thermo-gravity convection in a large volume vertical cylinder. The heat is removed from the product via the cooling jacket at the top of the cylinder. We suppose that a laminar fluid motion takes place. The model is based on the NavierStokes equation, the equation of heat transfer through the wall, and the heat transfer equation. The peculiarity of the process in large volume tanks was the distribution of the physical parameters of the coordinates that was taken into account when constructing the model. The model corresponds to a process of wort beer fermentation in the cylindrical-conical tanks (CCT. The CCT volume is divided into three zones and for each zone model equations was obtained. The first zone has an annular cross-section and it is limited to the height by the cooling jacket. In this zone the heat flow from the cooling jacket to the product is uppermost. Model equation of the first zone describes the process of heat transfer through the wall and is presented by linear inhomogeneous differential equation in partial derivatives that is solved analytically. For the second and third zones description there was a number of engineering assumptions. The fluid was considered Newtonian, viscous and incompressible. Convective motion considered in the Boussinesq approximation. The effect of viscous dissipation is not considered. The topology of fluid motion is similar to the cylindrical Poiseuille. The second zone model consists of the Navier-Stokes equations in cylindrical coordinates with the introduction of a simplified and the heat equation in the liquid layer. The volume that is occupied by an upward convective flow pertains to the third area. Convective flows do not mix and do not exchange heat. At the start of the process a medium has the same temperature and a zero initial velocity in the whole volume that allows us to specify the initial conditions for the process. The paper shows the

  9. Automated transmission-mode scanning electron microscopy (tSEM for large volume analysis at nanoscale resolution.

    Directory of Open Access Journals (Sweden)

    Masaaki Kuwajima

    Full Text Available Transmission-mode scanning electron microscopy (tSEM on a field emission SEM platform was developed for efficient and cost-effective imaging of circuit-scale volumes from brain at nanoscale resolution. Image area was maximized while optimizing the resolution and dynamic range necessary for discriminating key subcellular structures, such as small axonal, dendritic and glial processes, synapses, smooth endoplasmic reticulum, vesicles, microtubules, polyribosomes, and endosomes which are critical for neuronal function. Individual image fields from the tSEM system were up to 4,295 µm(2 (65.54 µm per side at 2 nm pixel size, contrasting with image fields from a modern transmission electron microscope (TEM system, which were only 66.59 µm(2 (8.160 µm per side at the same pixel size. The tSEM produced outstanding images and had reduced distortion and drift relative to TEM. Automated stage and scan control in tSEM easily provided unattended serial section imaging and montaging. Lens and scan properties on both TEM and SEM platforms revealed no significant nonlinear distortions within a central field of ∼100 µm(2 and produced near-perfect image registration across serial sections using the computational elastic alignment tool in Fiji/TrakEM2 software, and reliable geometric measurements from RECONSTRUCT™ or Fiji/TrakEM2 software. Axial resolution limits the analysis of small structures contained within a section (∼45 nm. Since this new tSEM is non-destructive, objects within a section can be explored at finer axial resolution in TEM tomography with current methods. Future development of tSEM tomography promises thinner axial resolution producing nearly isotropic voxels and should provide within-section analyses of structures without changing platforms. Brain was the test system given our interest in synaptic connectivity and plasticity; however, the new tSEM system is readily applicable to other biological systems.

  10. Single-well and inter-well dual-tracer test design for quantifying phase volumes and interface areas in subsurface flow and transport systems

    Science.gov (United States)

    Ghergut, I.; Behrens, H.; Licha, T.; Maier, F.; Nottebohm, M.; Schaffer, M.; Sauter, M.

    2012-04-01

    Technology-relevant georeservoirs in the realm of energy production (such as: spent-radionuclide repositories, gas-storage, geothermal, as well as CCS candidate reservoirs) contain mobile and immobile fluid regions, and often also different fluid and solid phases. The lifetime of a particular reservoir (from a hydraulic, thermal, geomechanical and/or hydrogeochemical point of view) depends on the volumes and/or interface areas of some of these regions and/or phases. Mostly, their lifetime-effective values cannot be measured by geophysical and hydraulic methods. Since they essentially relate to fluid-based transport processes, attempting to measure them by tracer tests is a sensible endeavour. However, in designing and dimensioning such tracer tests, one should keep in mind that not every tracer test is sensitive w. r. to every fluid transport parameter. A certain complementarity exists, w. r. to parameter sensitivity, between single-well and inter-well methods, between equilibrium and kinetic exchange processes, between volume and area parameters. Mobile-fluid volumes can be measured from inter-well conservative-tracer tests, whereas single-well push-pull tests are generally insensitive w. r. to mobile-fluid volumes. Immobile-fluid volumes, in single-phase systems, are rather difficult to measure, by either kind of test. Different-phase volumes can be determined from inter-well tests using partitioning tracers at equilibrium exchange between phases; whereas single-well tracer push-pull tests are rather insensitive w. r. to tracer exchange processes at equilibrium. Im-/mobile fluid, or inter-phase interface areas can be determined from single-well tracer push-pull tests relying on kinetic exchange processes between compartments or phases. Single-well tests are often believed to be more sensitive w. r. to such processes than w. r. to advective-dispersive processes, and than inter-well tests. Inter-well tests are not physically insensitive w. r. to kinetic exchange

  11. The consequences of metric production for small manufacturers. Volume 2: Case studies of large business-small business interactions

    Science.gov (United States)

    Hitchcock, H. H.; Coates, J. F.; Canavan, M. M.; Prillaman, G. H.; Nettles, M. S.

    1982-02-01

    Over the last decade, controversy, concern, and conjecture have surrounded the effects of metric conversion on small business. Enthusiasts for metric argue that conversion would benefit small businesses in two ways. It would expand their markets, especially export markets. It would also improve business by making production processes more rational. Dissenters argue that conversion is unnecessary and possibly harmful to the majority of the nation's small businesses. Against this backdrop, the U.S. Metric Board is fulfilling its statutory mission to find out what happens to small businesses that convert to metric. The first phase of the project was a search for small businesses that had made substantial investments in converting to metric. That search showed that small businesses were most likely to invest in metric production in response to large corporations' needs for metric parts and products. The second phase of the research consisted of three case studies of the effects of large companies' conversion on small business suppliers. The team studied how the conversion of a General Electric Company department, two Ford Motor Company product lines, and three divisions of Ingersoll-Rand affected their small business suppliers.

  12. The microclimate parameters change in the occupied zone inside some large-volume buildings with significant influence of the heat emission from people staying inside

    Science.gov (United States)

    Albert Jelec, Paweł

    2017-10-01

    The paper shows selected aspects of the microclimate change in the occupied zone of the large-volume buildings. The air temperature and some other microclimate parameters change because of heat emission from people staying inside there. There are shown exemplary methods and results of research conducted in sacral buildings and residential apartment buildings. It is based on author's research. The novelty is the research of the human heat emission in case of a big number of people staying inside sacral buildings. It can be useful for a large-volume buildings design (especially for the sacral buildings) and for microclimate shaping in many types of buildings and residential buildings also. In some buildings with a big number of people staying inside at the same time (such as the sacral buildings) heat emitted from people significantly influences on microclimate. Another situation is observed in residential apartment buildings, where heat and moisture gain are distributed in separate rooms. Human heat streams can be useful as a part of the heat balance of the room especially in case the big number of people staying in the room.

  13. Comparison of procedures for immediate reconstruction of large osseous defects resulting from removal of a single tooth to prepare for insertion of an endosseous implant after healing

    NARCIS (Netherlands)

    Raghoebar, G. M.; Slater, J. J. H.; den Hartog, L.; Meijer, H. J. A.; Vissink, A.

    This study evaluated the treatment outcome of immediate reconstruction of 45 large osseous defects resulting from removal of a single tooth with a 1:2 mixture of Bio-Oss(R) and autologous tuberosity bone, and three different procedures for soft tissue closing (Bio-Gide(R) membrane, connective tissue

  14. Correction: Challenge in optoelectronic duplex switches: a red emission large-size single crystal and a unidirectional flexible thin film of a hybrid multifunctional material.

    Science.gov (United States)

    Zhu, Xiao; Zhang, Wan-Ying; Chen, Cheng; Ye, Qiong; Fu, Da-Wei

    2018-02-20

    Correction for 'Challenge in optoelectronic duplex switches: a red emission large-size single crystal and a unidirectional flexible thin film of a hybrid multifunctional material' by Xiao Zhu et al., Dalton Trans., 2018, DOI: 10.1039/c7dt04489e.

  15. CoV2O6 single crystals grown in a closed crucible: unusual magnetic behaviors with large anisotropy and 1/3 magnetization plateau.

    Science.gov (United States)

    He, Zhangzhen; Yamaura, Jun-ichi; Ueda, Yutaka; Cheng, Wendan

    2009-06-10

    Single crystals of CoV(2)O(6) were obtained in a closed crucible using a flux method. Magnetic measurements showed that this material displays a large magnetic anisotropy and a 1/3 magnetization plateau under a magnetic field applied along the c axis.

  16. Impact of injection speed and volume on perceived pain during subcutaneous injections into the abdomen and thigh: a single-centre, randomized controlled trial.

    Science.gov (United States)

    Heise, T; Nosek, L; Dellweg, S; Zijlstra, E; Præstmark, K A; Kildegaard, J; Nielsen, G; Sparre, T

    2014-10-01

    The aim of this study was to assess pain associated with subcutaneous injection into the abdomen and thigh of different combinations of injection speeds and volumes. The study was a single-centre, one-visit, double-blinded, randomized controlled trial in 82 adults with type 1 or type 2 diabetes receiving daily injections of insulin or glucagon-like peptide-1 (GLP-1) agonists. Participants received 17 subcutaneous injections (12 in abdomen, 5 in thigh) of saline at different injection speeds (150, 300 and 450 µl/s), with different volumes (400, 800, 1200 and 1600 µl), and two needle insertions without any injection. Pain was evaluated on a 100-mm visual analogue scale (VAS) (0 mm no pain, 100 mm worst pain) and on a yes/no scale for pain acceptability. Injection speed had no impact on injection pain (p = 0.833). Injection of larger volumes caused significantly more pain [VAS least square mean differences 1600 vs. 400 µl, 7 · 2 mm (95% confidence interval - CI; 4.6-9.7; p technique to reduce their injection pain. Furthermore, these findings may have important implications for the development of new injection devices and drug formulations for clinical practice. © 2014 John Wiley & Sons Ltd.

  17. Columbia University flow instability experimental program: Volume 2. Single tube uniformly heated tests -- Part 2: Uncertainty analysis and data

    International Nuclear Information System (INIS)

    Dougherty, T.; Maciuca, C.; McAssey, E.V. Jr.; Reddy, D.G.; Yang, B.W.

    1990-05-01

    In June 1988, Savannah River Laboratory requested that the Heat Transfer Research Facility modify the flow excursion program, which had been in progress since November 1987, to include testing of single tubes in vertical down-flow over a range of length to diameter (L/D) ratios of 100 to 500. The impetus for the request was the desire to obtain experimental data as quickly as possible for code development work. In July 1988, HTRF submitted a proposal to SRL indicating that by modifying a facility already under construction the data could be obtained within three to four months. In January 1990, HTFR issued report CU-HTRF-T4, part 1. This report contained the technical discussion of the results from the single tube uniformly heated tests. The present report is part 2 of CU-HTRF-T4 which contains further discussion of the uncertainty analysis and the complete set of data

  18. Strain Library Imaging Protocol for high-throughput, automated single-cell microscopy of large bacterial collections arrayed on multiwell plates.

    Science.gov (United States)

    Shi, Handuo; Colavin, Alexandre; Lee, Timothy K; Huang, Kerwyn Casey

    2017-02-01

    Single-cell microscopy is a powerful tool for studying gene functions using strain libraries, but it suffers from throughput limitations. Here we describe the Strain Library Imaging Protocol (SLIP), which is a high-throughput, automated microscopy workflow for large strain collections that requires minimal user involvement. SLIP involves transferring arrayed bacterial cultures from multiwell plates onto large agar pads using inexpensive replicator pins and automatically imaging the resulting single cells. The acquired images are subsequently reviewed and analyzed by custom MATLAB scripts that segment single-cell contours and extract quantitative metrics. SLIP yields rich data sets on cell morphology and gene expression that illustrate the function of certain genes and the connections among strains in a library. For a library arrayed on 96-well plates, image acquisition can be completed within 4 min per plate.

  19. Nanoplasma dynamics of single large xenon clusters irradiated with superintense x-ray pulses from the linac coherent light source free-electron laser.

    Science.gov (United States)

    Gorkhover, T; Adolph, M; Rupp, D; Schorb, S; Epp, S W; Erk, B; Foucar, L; Hartmann, R; Kimmel, N; Kühnel, K-U; Rolles, D; Rudek, B; Rudenko, A; Andritschke, R; Aquila, A; Bozek, J D; Coppola, N; Erke, T; Filsinger, F; Gorke, H; Graafsma, H; Gumprecht, L; Hauser, G; Herrmann, S; Hirsemann, H; Hömke, A; Holl, P; Kaiser, C; Krasniqi, F; Meyer, J-H; Matysek, M; Messerschmidt, M; Miessner, D; Nilsson, B; Pietschner, D; Potdevin, G; Reich, C; Schaller, G; Schmidt, C; Schopper, F; Schröter, C D; Schulz, J; Soltau, H; Weidenspointner, G; Schlichting, I; Strüder, L; Ullrich, J; Möller, T; Bostedt, C

    2012-06-15

    The plasma dynamics of single mesoscopic Xe particles irradiated with intense femtosecond x-ray pulses exceeding 10(16)  W/cm2 from the Linac Coherent Light Source free-electron laser are investigated. Simultaneous recording of diffraction patterns and ion spectra allows eliminating the influence of the laser focal volume intensity and particle size distribution. The data show that for clusters illuminated with intense x-ray pulses, highly charged ionization fragments in a narrow distribution are created and that the nanoplasma recombination is efficiently suppressed.

  20. JUICE: a data management system that facilitates the analysis of large volumes of information in an EST project workflow

    Directory of Open Access Journals (Sweden)

    Martinez Veronica

    2006-11-01

    Full Text Available Abstract Background Expressed sequence tag (EST analyses provide a rapid and economical means to identify candidate genes that may be involved in a particular biological process. These ESTs are useful in many Functional Genomics studies. However, the large quantity and complexity of the data generated during an EST sequencing project can make the analysis of this information a daunting task. Results In an attempt to make this task friendlier, we have developed JUICE, an open source data management system (Apache + PHP + MySQL on Linux, which enables the user to easily upload, organize, visualize and search the different types of data generated in an EST project pipeline. In contrast to other systems, the JUICE data management system allows a branched pipeline to be established, modified and expanded, during the course of an EST project. The web interfaces and tools in JUICE enable the users to visualize the information in a graphical, user-friendly manner. The user may browse or search for sequences and/or sequence information within all the branches of the pipeline. The user can search using terms associated with the sequence name, annotation or other characteristics stored in JUICE and associated with sequences or sequence groups. Groups of sequences can be created by the user, stored in a clipboard and/or downloaded for further analyses. Different user profiles restrict the access of each user depending upon their role in the project. The user may have access exclusively to visualize sequence information, access to annotate sequences and sequence information, or administrative access. Conclusion JUICE is an open source data management system that has been developed to aid users in organizing and analyzing the large amount of data generated in an EST Project workflow. JUICE has been used in one of the first functional genomics projects in Chile, entitled "Functional Genomics in nectarines: Platform to potentiate the competitiveness of Chile in