WorldWideScience

Sample records for single ion monitoring

  1. Single Cathode Ion Thruster

    Data.gov (United States)

    National Aeronautics and Space Administration — Objective is to design an electrostatic ion thruster that is more efficient, simpler, and lower cost than the current gridded ion thruster. Initial objective is to...

  2. Ion beam monitoring

    International Nuclear Information System (INIS)

    McKinney, C.R.

    1980-01-01

    An ion beam analyzer is specified, having an ion source for generating ions of a sample to be analyzed, means for extracting the sample ions, means for focusing the sample ions into a beam, separation means positioned along the ion beam for selectively deflecting species of ions, and means for detecting the selected species of ions. According to the specification, the analyzer further comprises (a) means for disabling at least a portion of the separation means, such that the ion beam from the source remains undeflected; (b) means located along the path of the undeflected ion beam for sensing the sample ions; and (c) enabling means responsive to the sensing means for automatically re-enabling the separation means when the sample ions reach a predetermined intensity level. (author)

  3. A single-cell correlative nanoelectromechanosensing approach to detect cancerous transformation: monitoring the function of F-actin microfilaments in the modulation of the ion channel activity

    Science.gov (United States)

    AbdolahadThe Authors With Same Contributions., Mohammad; Saeidi, Ali; Janmaleki, Mohsen; Mashinchian, Omid; Taghinejad, Mohammad; Taghinejad, Hossein; Azimi, Soheil; Mahmoudi, Morteza; Mohajerzadeh, Shams

    2015-01-01

    Cancerous transformation may be dependent on correlation between electrical disruptions in the cell membrane and mechanical disruptions of cytoskeleton structures. Silicon nanotube (SiNT)-based electrical probes, as ultra-accurate signal recorders with subcellular resolution, may create many opportunities for fundamental biological research and biomedical applications. Here, we used this technology to electrically monitor cellular mechanosensing. The SiNT probe was combined with an electrically activated glass micropipette aspiration system to achieve a new cancer diagnostic technique that is based on real-time correlation between mechanical and electrical behaviour of single cells. Our studies demonstrated marked changes in the electrical response following increases in the mechanical aspiration force in healthy cells. In contrast, such responses were extremely weak for malignant cells. Confocal microscopy results showed the impact of actin microfilament remodelling on the reduction of the electrical response for aspirated cancer cells due to the significant role of actin in modulating the ion channel activity in the cell membrane.Cancerous transformation may be dependent on correlation between electrical disruptions in the cell membrane and mechanical disruptions of cytoskeleton structures. Silicon nanotube (SiNT)-based electrical probes, as ultra-accurate signal recorders with subcellular resolution, may create many opportunities for fundamental biological research and biomedical applications. Here, we used this technology to electrically monitor cellular mechanosensing. The SiNT probe was combined with an electrically activated glass micropipette aspiration system to achieve a new cancer diagnostic technique that is based on real-time correlation between mechanical and electrical behaviour of single cells. Our studies demonstrated marked changes in the electrical response following increases in the mechanical aspiration force in healthy cells. In contrast, such

  4. Single ion dynamics in molten sodium bromide

    Energy Technology Data Exchange (ETDEWEB)

    Alcaraz, O.; Trullas, J. [Departament de Física i Enginyeria Nuclear, Universitat Politècnica de Catalunya, 08034 Barcelona (Spain); Demmel, F. [ISIS Facility, Rutherford Appleton Laboratory, Didcot OX11 0QX (United Kingdom)

    2014-12-28

    We present a study on the single ion dynamics in the molten alkali halide NaBr. Quasielastic neutron scattering was employed to extract the self-diffusion coefficient of the sodium ions at three temperatures. Molecular dynamics simulations using rigid and polarizable ion models have been performed in parallel to extract the sodium and bromide single dynamics and ionic conductivities. Two methods have been employed to derive the ion diffusion, calculating the mean squared displacements and the velocity autocorrelation functions, as well as analysing the increase of the line widths of the self-dynamic structure factors. The sodium diffusion coefficients show a remarkable good agreement between experiment and simulation utilising the polarisable potential.

  5. Single-ion nonlinear mechanical oscillator

    International Nuclear Information System (INIS)

    Akerman, N.; Kotler, S.; Glickman, Y.; Dallal, Y.; Keselman, A.; Ozeri, R.

    2010-01-01

    We study the steady-state motion of a single trapped ion oscillator driven to the nonlinear regime. Damping is achieved via Doppler laser cooling. The ion motion is found to be well described by the Duffing oscillator model with an additional nonlinear damping term. We demonstrate here the unique ability of tuning both the linear as well as the nonlinear damping coefficients by controlling the laser-cooling parameters. Our observations pave the way for the investigation of nonlinear dynamics on the quantum-to-classical interface as well as mechanical noise squeezing in laser-cooling dynamics.

  6. Single Pass Optical Profile Monitoring

    CERN Document Server

    Jung, R; Hutchins, Stephen

    2003-01-01

    Beam profiles are acquired in transfer lines to monitor extracted beams and compute their emittance. Measurements performed on the first revolutions of a ring will evaluate the matching of a chain of accelerators. Depending on the particle type and energy, these measurements are in general performed with screens, making either use of Luminescence or Optical Transition Radiation [OTR], and the generated beam images are acquired with sensors of various types. Sometimes the beam position is also measured this way. The principle, advantages and disadvantages of both families of screens will be discussed in relation with the detectors used. Test results with beam and a possible evaluation method for luminescent screens will be presented. Finally other optical methods used will be mentioned for completeness.

  7. Towards single Ce ion detection in a bulk crystal for the development of a single-ion qubit readout scheme

    OpenAIRE

    Yan, Ying

    2013-01-01

    The work presented in this thesis was concerned with investigating the relevant spectroscopic properties of Ce ions randomly doped in an Y2SiO5 crystal at low temperatures (around 4 K), in order to develop a technique and an experimental set-up to detect the fluorescence photons emitted by a single Ce ion. The aim of the work was to determine whether a single Ce ion (referred to as the readout ion) can be used as a local probe to sense the quantum state of a neighbouring single-ion qubit via ...

  8. Coherent Control of a Single Trapped Rydberg Ion

    Science.gov (United States)

    Higgins, Gerard; Pokorny, Fabian; Zhang, Chi; Bodart, Quentin; Hennrich, Markus

    2017-12-01

    Trapped Rydberg ions are a promising novel approach to quantum computing and simulations. They are envisaged to combine the exquisite control of trapped ion qubits with the fast two-qubit Rydberg gates already demonstrated in neutral atom experiments. Coherent Rydberg excitation is a key requirement for these gates. Here, we carry out the first coherent Rydberg excitation of an ion and perform a single-qubit Rydberg gate, thus demonstrating basic elements of a trapped Rydberg ion quantum computer.

  9. Single ion counting with a MCP (microchannel plate) detector

    Energy Technology Data Exchange (ETDEWEB)

    Tawara, Hiroko; Sasaki, Shinichi; Miyajima, Mitsuhiro [National Lab. for High Energy Physics, Tsukuba, Ibaraki (Japan); Shibamura, Eido

    1996-07-01

    In this study, a single-ion-counting method using alpha-particle-impact ionization of Ar atoms is demonstrated and the preliminary {epsilon}{sub mcp} for Ar ions with incident energies of 3 to 4.7 keV is determined. The single-ion counting by the MCP is aimed to be performed under experimental conditions as follows: (1) A signal from the MCP is reasonably identified as incidence of single Ar-ion. (2) The counting rate of Ar ions is less than 1 s{sup -1}. (3) The incident Ar ions are not focused on a small part of an active area of the MCP, namely, {epsilon}{sub mcp} is determined with respect to the whole active area of the MCP. So far, any absolute detection efficiency has not been reported under these conditions. (J.P.N.)

  10. Automated parallel recordings of topologically identified single ion channels.

    Science.gov (United States)

    Kawano, Ryuji; Tsuji, Yutaro; Sato, Koji; Osaki, Toshihisa; Kamiya, Koki; Hirano, Minako; Ide, Toru; Miki, Norihisa; Takeuchi, Shoji

    2013-01-01

    Although ion channels are attractive targets for drug discovery, the systematic screening of ion channel-targeted drugs remains challenging. To facilitate automated single ion-channel recordings for the analysis of drug interactions with the intra- and extracellular domain, we have developed a parallel recording methodology using artificial cell membranes. The use of stable lipid bilayer formation in droplet chamber arrays facilitated automated, parallel, single-channel recording from reconstituted native and mutated ion channels. Using this system, several types of ion channels, including mutated forms, were characterised by determining the protein orientation. In addition, we provide evidence that both intra- and extracellular amyloid-beta fragments directly inhibit the channel open probability of the hBK channel. This automated methodology provides a high-throughput drug screening system for the targeting of ion channels and a data-intensive analysis technique for studying ion channel gating mechanisms.

  11. Single track regime in ion implanted polystyrene

    Energy Technology Data Exchange (ETDEWEB)

    Licciardello, A.; Puglisi, O.; Calcagno, L.; Foti, G.

    1988-05-01

    The molecular weight distribution (MWD) of nearly monodisperse polystyrene thin films is heavily affected by ion bombardment. The main effect is an increase of the MW and is detectable at fluences as low as 10/sup 11/ ions cm/sup -2/ for 400 keV Ar/sup +/ bombardment. A statistical model, here outlined for the first time, allows us the predict the size distribution of these high MW components. From the analysis of the MWD curves one can extract useful information concerning the lateral dimensions of the ion tracks.

  12. A compact source for bunches of singly charged atomic ions

    Science.gov (United States)

    Murböck, T.; Schmidt, S.; Andelkovic, Z.; Birkl, G.; Nörtershäuser, W.; Vogel, M.

    2016-04-01

    We have built, operated, and characterized a compact ion source for low-energy bunches of singly charged atomic ions in a vacuum beam line. It is based on atomic evaporation from an electrically heated oven and ionization by electron impact from a heated filament inside a grid-based ionization volume. An adjacent electrode arrangement is used for ion extraction and focusing by applying positive high-voltage pulses to the grid. The method is particularly suited for experimental environments which require low electromagnetic noise. It has proven simple yet reliable and has been used to produce μs-bunches of up to 106 Mg+ ions at a repetition rate of 1 Hz. We present the concept, setup and characterizing measurements. The instrument has been operated in the framework of the SpecTrap experiment at the HITRAP facility at GSI/FAIR to provide Mg+ ions for sympathetic cooling of highly charged ions by laser-cooled 24Mg+.

  13. Ion Mobility Spectrometry for Water Monitoring

    Data.gov (United States)

    National Aeronautics and Space Administration — Current water quality monitors aboard the International Space Station (ISS) are specialized and provide limited data. As water and air samples are often analyzed...

  14. Monitoring single-channel water permeability in polarized cells.

    Science.gov (United States)

    Erokhova, Liudmila; Horner, Andreas; Kügler, Philipp; Pohl, Peter

    2011-11-18

    So far the determination of unitary permeability (p(f)) of water channels that are expressed in polarized cells is subject to large errors because the opening of a single water channel does not noticeably increase the water permeability of a membrane patch above the background. That is, in contrast to the patch clamp technique, where the single ion channel conductance may be derived from a single experiment, two experiments separated in time and/or space are required to obtain the single-channel water permeability p(f) as a function of the incremental water permeability (P(f,c)) and the number (n) of water channels that contributed to P(f,c). Although the unitary conductance of ion channels is measured in the native environment of the channel, p(f) is so far derived from reconstituted channels or channels expressed in oocytes. To determine the p(f) of channels from live epithelial monolayers, we exploit the fact that osmotic volume flow alters the concentration of aqueous reporter dyes adjacent to the epithelia. We measure these changes by fluorescence correlation spectroscopy, which allows the calculation of both P(f,c) and osmolyte dilution within the unstirred layer. Shifting the focus of the laser from the aqueous solution to the apical and basolateral membranes allowed the FCS-based determination of n. Here we validate the new technique by determining the p(f) of aquaporin 5 in Madin-Darby canine kidney cell monolayers. Because inhibition and subsequent activity rescue are monitored on the same sample, drug effects on exocytosis or endocytosis can be dissected from those on p(f).

  15. Anisotropic Lithium Ion Conductivity in Single-Ion Diblock Copolymer Electrolyte Thin Films

    NARCIS (Netherlands)

    Aissou, Karim; Mumtaz, Muhammad; Usluer, Özlem; Pécastaings, Gilles; Portale, Giuseppe; Fleury, Guillaume; Cloutet, Eric; Hadziioannou, Georges

    Well-defined single-ion diblock copolymers consisting of a Li-ion conductive poly(styrenesulfonyllithium(trifluoromethylsulfonyl)imide) (PSLiTFSI) block associated with a glassy polystyrene (PS) block have been synthesized via reversible addition fragmentation chain transfer polymerization.

  16. Conduction in ion implanted single crystal diamond

    International Nuclear Information System (INIS)

    Hunn, J.D.; Parikh, N.R.; Swanson, M.L.

    1992-01-01

    We have implanted sodium, phosphorus and arsenic into single crystal type IIa diamond as possible n-type dopants. Particular emphasis was applied to the implantation of sodium at different temperatures and doses; combined implantation energies of 55,80 and 120 keV were used to provide a uniformly doped layer over approximately 100 nm depth. The implanted layers exhibited semiconducting behavior with a single exponential activation energy between 0.40 and 0.48 eV, as determined by temperature dependent resistance measurements. A sample implanted to a concentration of 5.10 19 Na + /cm 3 at 550 degrees C exhibited a single activation energy of 0.415 eV over a temperature range from 25 to 500 degrees C. Thermal annealing above 900 degrees C was found to remove implantation damage as measured by optical absorption and RBS/channeling. However, concomitant increases in the resistance and the activation energy were observed. Implantation of 22 Ne was used to introduce a damage density equivalent to the 23 Na implant, while not introducing an electrically active species. The activation energy and electrical resistance were similar but higher than those produced by implantation with sodium. We conclude that the electrical properties of the Na-implanted samples were at least partly due to electrically active Na, but that residual implantation damage was still important

  17. Localization Spectroscopy of a Single Ion in an Optical Lattice

    DEFF Research Database (Denmark)

    Legrand, Olivier Philippe Alexandre

    2015-01-01

    The work reported in this thesis primarily focuses on studies of the dynamics of a single laser-cooled ion, simultaneously confined in the harmonic potential of a linear Paul trap and a rapidly varying periodic potential – a so-called optical lattice – generated from an optical standing-wave. Bes......The work reported in this thesis primarily focuses on studies of the dynamics of a single laser-cooled ion, simultaneously confined in the harmonic potential of a linear Paul trap and a rapidly varying periodic potential – a so-called optical lattice – generated from an optical standing...... calibration and analysis of the detection system, several theoretical simulations of the expected dynamics and associated optical response of the ion were undertaken. Finally, a new laser source based on second harmonic generation was developed in order to perform laser-cooling of Ca+ ions, and to serve...

  18. Ion implantation induced blistering of rutile single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Xiang, Bing-Xi [School of Physics, Shandong University, Jinan, Shandong 250100 (China); Jiao, Yang [College of Physics and Electronics, Shandong Normal University, Jinan, Shandong 250100 (China); Guan, Jing [School of Physics, Shandong University, Jinan, Shandong 250100 (China); Wang, Lei [School of Physics, Shandong University, Jinan, Shandong 250100 (China); Key Laboratory of Nanodevices and Applications, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences (China)

    2015-07-01

    The rutile single crystals were implanted by 200 keV He{sup +} ions with a series fluence and annealed at different temperatures to investigate the blistering behavior. The Rutherford backscattering spectrometry, optical microscope and X-ray diffraction were employed to characterize the implantation induced lattice damage and blistering. It was found that the blistering on rutile surface region can be realized by He{sup +} ion implantation with appropriate fluence and the following thermal annealing.

  19. Single Ion Trapping for the Enriched Xenon Observatory

    Energy Technology Data Exchange (ETDEWEB)

    Waldman, Samuel J.; /Stanford U., Phys. Dept. /SLAC

    2006-03-28

    In the last decade, a variety of neutrino oscillation experiments have established that there is a mass difference between neutrino flavors, without determining the absolute neutrino mass scale. The Enriched Xenon Observatory for neutrinoless double beta decay (EXO) will search for the rare decays of xenon to determine the absolute value of the neutrino mass. The experiment uses a novel technique to minimize backgrounds, identifying the decay daughter product in real time using single ion spectroscopy. Here, we describe single ion trapping and spectroscopy compatible with the EXO detector. We extend the technique of single ion trapping in ultrahigh vacuum to trapping in xenon gas. With this technique, EXO will achieve a neutrino mass sensitivity of {approx_equal} .010 eV.

  20. Radiogas chromatography mass spectrometry in the selected ion monitoring mode

    International Nuclear Information System (INIS)

    Doerfler, D.L.; Rosenblum, E.R.; Malloy, J.M.; Naworal, J.D.; McManus, I.R.; Campbell, I.M.

    1980-01-01

    The value of selected ion monitoring in analyzing biological radio isotope incorporation experiments by radiogas chromatography mass spectrometry is illustrated with reference to the biosynthesis of the mycotoxin mycophenolic acid in Penicillium brevicompactum and the mode of action of the anticholesterolemic drug 20,25-diazacholesterol. Both examples used 1-[ 14 C]acetate precursors. It is shown that the increased sensitivity and specificity of the selected ion monitoring mode detector permits straightforward detection and identification of the relatively small cellular pools associated with metabolic intermediates. The computer program RADSIM is described. Problems that still exist in using radiogas gas chromatography mass spectrometry technology to analyse isotope incorporation experiments are discussed. (author)

  1. The SupraThermal Ion Monitor for space weather predictions.

    Science.gov (United States)

    Allegrini, F; Desai, M I; Livi, S; McComas, D J; Ho, G C

    2014-05-01

    Measurement of suprathermal energy ions in the heliosphere has always been challenging because (1) these ions are situated in the energy regime only a few times higher than the solar wind plasma, where intensities are orders of magnitude higher and (2) ion energies are below or close to the threshold of state-of-art solid-state detectors. Suprathermal ions accelerated at coronal mass ejection-driven shocks propagate out ahead of the shocks. These shocks can cause geomagnetic storms in the Earth's magnetosphere that can affect spacecraft and ground-based power and communication systems. An instrument with sufficient sensitivity to measure these ions can be used to predict the arrival of the shocks and provide an advance warning for potentially geo-effective space weather. In this paper, we present a novel energy analyzer concept, the Suprathermal Ion Monitor (STIM) that is designed to measure suprathermal ions with high sensitivity. We show results from a laboratory prototype and demonstrate the feasibility of the concept. A list of key performances is given, as well as a discussion of various possible detectors at the back end. STIM is an ideal candidate for a future space weather monitor in orbit upstream of the near-earth environment, for example, around L1. A scaled-down version is suitable for a CubeSat mission. Such a platform allows proofing the concept and demonstrating its performance in the space environment.

  2. Ion Source Multiplexing on a Single Mass Spectrometer.

    Science.gov (United States)

    Kostyukevich, Yury; Nikolaev, Eugene

    2018-03-06

    We present the simple approach for the combination of different ion sources on a single mass spectrometer without any interference between them. Each ion source can be positioned as far as 1 m from the mass spectrometer; ions are transported by the means of flexible copper tubes, which are connected, to the separate inlet capillaries. Special valves enable switching channels on and off. Using this approach, we successfully combined native electrospray ionization (ESI), regular ESI, β-electrons ionization, and atmospheric pressure photoionization (APPI) of thermally desorbed vapors of petroleum on a single mass spectrometer. In addition, separate channels allow infusing internal calibration mixture or performing ion molecular reactions in one channel and using the other as a reference. Using this idea, we have developed an original sequential window acquisition of all theoretical mass spectra (SWATH MS) approach in which peptide ions are transported in different channels, one of which is heated to high temperature so that ions are thermally fragmented, and the other channel ensures the presence of nonfragmented ions in the spectrum. Also, we demonstrated the possibility to perform gas phase H/D exchange reaction in one channel and using another as reference. Use of valves makes it possible to exclude any interference between them. Thus, we have demonstrated the possibility to create a multichannel system in which ions would be transported through several inlet tubes in which different ion molecular reactions such as Paternò-Büchi, ozonation, or H/D exchange will occur. Comparison of mass spectra recorded when different channels are open will provide structural and chemical information about unknown species.

  3. Modification of ion implanted or irradiated single crystal sapphire

    International Nuclear Information System (INIS)

    Song Yin; Zhang Chonghong; Wang Zhiguang; Zhao Zhiming; Yao Cunfeng; Zhou Lihong; Jin Yunfan

    2006-01-01

    Single crystal sapphire (Al 2 O 3 ) samples were implanted at 600 K by He, Ne and Ar ions with energy of 110 keV to doses ranging from 5 x 10 16 to 2 x 10 17 ion/cm 2 or irradiated at 320 K by 208 Pb 27+ ion with energy of 1.1 MeV/u to the fluences ranging from 1 x 10 12 to 5 x 10 14 ion/cm 2 . The modification of structure and optical properties induced by ion implantation or irradiation were analyzed by using photoluminescence (PL) and Fourier transformation infrared spectrum (FTIR) spectra and transmission electron microscopy (TEM) measurements. The PL measurements showed that absorption peaks located at 375, 413 and 450 nm appeared in all the implanted or irradiated samples, the PL intensities reached up to the maximum for the 5 x 10 16 ion/cm 2 implanted samples. After Pb-ion irradiation, a new peak located at 390 nm formed. TEM analyses showed that small size voids (1-2 nm) with high density were formed in the region from the surface till to about 100 nm in depth and also large size Ne-bubble formed in the Ne-doped region. Form the obtained FTIR spectra, it was found that Pb-ion irradiation induced broadening of the absorption band in 460-510 cm -1 and position shift of the absorption band in 1000-1300 cm -1 towards to high wavenumber. The possible damage mechanism in single crystal sapphire induced by energetic ion implantation or irradiation was briefly discussed. (authors)

  4. Fast-scan monitor examines neutral-beam ion-density profile

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    All of the magnetic mirror confinement fusion experiments at LLL and at other laboratories depend on pulsed, energetic neutral-beam injection for fueling and imparting energy to the trapped plasma for density build-up and stability studies. It is vital to be able to monitor how well the injected ion beam is aimed and focused. To do this, we have designed an ion-beam current-density profile monitor that uses a commercial minimodular data acquisition system. Our prototype model monitors a single 20-kV, 50-A, 10-ms beam. However, the method is applicable to any number of beams with similar sampling target arrays. Also, the electronics can be switched to monitor any one of several target collectors

  5. Surface noise analysis using a single-ion sensor

    Science.gov (United States)

    Daniilidis, N.; Gerber, S.; Bolloten, G.; Ramm, M.; Ransford, A.; Ulin-Avila, E.; Talukdar, I.; Häffner, H.

    2014-06-01

    We use a single-ion electric-field noise sensor in combination with in situ surface treatment and analysis tools, to investigate the relationship between electric-field noise from metal surfaces in vacuum and the composition of the surface. These experiments are performed in a setup that integrates ion trapping capabilities with surface analysis tools. We find that treatment of an aluminum-copper surface with energetic argon ions significantly reduces the level of room-temperature electric-field noise, but the surface does not need to be atomically clean to show noise levels comparable to those of the best cryogenic traps. The noise levels after treatment are low enough to allow fault-tolerant trapped-ion quantum information processing on a microfabricated surface trap at room temperature.

  6. Single qubit manipulation in a microfabricated surface electrode ion trap

    Science.gov (United States)

    Mount, Emily; Baek, So-Young; Blain, Matthew; Stick, Daniel; Gaultney, Daniel; Crain, Stephen; Noek, Rachel; Kim, Taehyun; Maunz, Peter; Kim, Jungsang

    2013-09-01

    We trap individual 171Yb+ ions in a surface trap microfabricated on a silicon substrate, and demonstrate a complete set of high fidelity single qubit operations for the hyperfine qubit. Trapping times exceeding 20 min without laser cooling, and heating rates as low as 0.8 quanta ms-1, indicate stable trapping conditions in these microtraps. A coherence time of more than 1 s, high fidelity qubit state detection and single qubit rotations are demonstrated. The observation of low heating rates and demonstration of high quality single qubit gates at room temperature are critical steps toward scalable quantum information processing in microfabricated surface traps.

  7. Single qubit manipulation in a microfabricated surface electrode ion trap

    International Nuclear Information System (INIS)

    Mount, Emily; Baek, So-Young; Gaultney, Daniel; Crain, Stephen; Noek, Rachel; Kim, Taehyun; Maunz, Peter; Kim, Jungsang; Blain, Matthew; Stick, Daniel

    2013-01-01

    We trap individual 171 Yb + ions in a surface trap microfabricated on a silicon substrate, and demonstrate a complete set of high fidelity single qubit operations for the hyperfine qubit. Trapping times exceeding 20 min without laser cooling, and heating rates as low as 0.8 quanta ms −1 , indicate stable trapping conditions in these microtraps. A coherence time of more than 1 s, high fidelity qubit state detection and single qubit rotations are demonstrated. The observation of low heating rates and demonstration of high quality single qubit gates at room temperature are critical steps toward scalable quantum information processing in microfabricated surface traps. (paper)

  8. Enriching lanthanide single-ion magnetism through symmetry and axiality.

    Science.gov (United States)

    Gupta, Sandeep K; Murugavel, Ramaswamy

    2018-04-10

    Rapidly growing modern information technology demands energy and cost efficient tools that can efficiently store and process a large amount of data. However, the miniaturization technology that was being used to boost the performance of the electronic devices, keeping up with the pace as estimated by Moore's law, is reaching its limit. To overcome these challenges, several alternative routes that can eventually mimic the modern electronics fabrication using silicon have been proposed. Single molecule magnets (SMMs), being considered as one of the potential alternatives, have gone through significant progress and the focus has shifted from the use of polynuclear clusters to mononuclear complexes in the last few years. The recent frenzy in the field of SMMs is driven by a better understanding of the effects of crystal field (CF) and molecular symmetry on the magnetic properties, especially in the case of mononuclear paramagnetic complexes, apart from other controlling factors. This has led to the advent of highly anisotropic single-ion magnets (SIMs) with magnetic blocking temperatures as high as 60 K and anisotropic energy barriers over 1800 K. This article overviews our recent research in the light of the emergence of the importance of CF and symmetry in 4f ion based single-ion magnets (SIMs), especially in the context of SIMs with D5h symmetry, apart from commenting on the synthetic efforts adopted to place these metal ions in unusual coordination geometries.

  9. Single Gold Nanorod Charge Modulation in an Ion Gel Device.

    Science.gov (United States)

    Collins, Sean S E; Wei, Xingzhan; McKenzie, Thomas G; Funston, Alison M; Mulvaney, Paul

    2016-11-09

    A reliable and reproducible method to rapidly charge single gold nanocrystals in a solid-state device is reported. Gold nanorods (Au NRs) were integrated into an ion gel capacitor, enabling them to be charged in a transparent and highly capacitive device, ideal for optical transmission. Changes in the electron concentration of a single Au NR were observed with dark-field imaging spectroscopy via localized surface plasmon resonance (LSPR) shifts in the scattering spectrum. A time-resolved, laser-illuminated, dark-field system was developed to enable direct measurement of single particle charging rates with time resolution below one millisecond. The added sensitivity of this new approach has enabled the optical detection of fewer than 110 electrons on a single Au NR. Single wavelength resonance shifts provide a much faster, more sensitive method for all surface plasmon-based sensing applications.

  10. Single ion impact detection and scanning probe aligned ion implantation for quantum bit formation

    International Nuclear Information System (INIS)

    Weis, Christoph D.

    2011-01-01

    Quantum computing and quantum information processing is a promising path to replace classical information processing via conventional computers which are approaching fundamental physical limits. Instead of classical bits, quantum bits (qubits) are utilized for computing operations. Due to quantum mechanical phenomena such as superposition and entanglement, a completely different way of information processing is achieved, enabling enhanced performance for certain problem sets. Various proposals exist on how to realize a quantum bit. Among them are electron or nuclear spins of defect centers in solid state systems. Two such candidates with spin degree of freedom are single donor atoms in silicon and nitrogen vacancy (NV) defect centers in diamond. Both qubit candidates possess extraordinary qualities which makes them promising building blocks. Besides certain advantages, the qubits share the necessity to be placed precisely in their host materials and device structures. A commonly used method is to introduce the donor atoms into the substrate materials via ion implantation. For this, focused ion beam systems can be used, or collimation techniques as in this work. A broad ion beam hits the back of a scanning probe microscope (SPM) cantilever with incorporated apertures. The high resolution imaging capabilities of the SPM allows the non destructive location of device areas and the alignment of the cantilever and thus collimated ion beam spot to the desired implant locations. In this work, this technique is explored, applied and pushed forward to meet necessary precision requirements. The alignment of the ion beam to surface features, which are sensitive to ion impacts and thus act as detectors, is demonstrated. The technique is also used to create NV center arrays in diamond substrates. Further, single ion impacts into silicon device structures are detected which enables deliberate single ion doping.

  11. Single ion impact detection and scanning probe aligned ion implantation for quantum bit formation

    Energy Technology Data Exchange (ETDEWEB)

    Weis, Christoph D.

    2011-10-04

    Quantum computing and quantum information processing is a promising path to replace classical information processing via conventional computers which are approaching fundamental physical limits. Instead of classical bits, quantum bits (qubits) are utilized for computing operations. Due to quantum mechanical phenomena such as superposition and entanglement, a completely different way of information processing is achieved, enabling enhanced performance for certain problem sets. Various proposals exist on how to realize a quantum bit. Among them are electron or nuclear spins of defect centers in solid state systems. Two such candidates with spin degree of freedom are single donor atoms in silicon and nitrogen vacancy (NV) defect centers in diamond. Both qubit candidates possess extraordinary qualities which makes them promising building blocks. Besides certain advantages, the qubits share the necessity to be placed precisely in their host materials and device structures. A commonly used method is to introduce the donor atoms into the substrate materials via ion implantation. For this, focused ion beam systems can be used, or collimation techniques as in this work. A broad ion beam hits the back of a scanning probe microscope (SPM) cantilever with incorporated apertures. The high resolution imaging capabilities of the SPM allows the non destructive location of device areas and the alignment of the cantilever and thus collimated ion beam spot to the desired implant locations. In this work, this technique is explored, applied and pushed forward to meet necessary precision requirements. The alignment of the ion beam to surface features, which are sensitive to ion impacts and thus act as detectors, is demonstrated. The technique is also used to create NV center arrays in diamond substrates. Further, single ion impacts into silicon device structures are detected which enables deliberate single ion doping.

  12. Analysis of abused drugs by selected ion monitoring: quantitative comparison of electron impact and chemical ionization

    International Nuclear Information System (INIS)

    Foltz, R.L.; Knowlton, D.A.; Lin, D.C.K.; Fentiman, A.F. Jr.

    1975-01-01

    A comparison was made of the relative sensitivities of electron impact and chemical ionization when used for selected ion monitoring analysis of commonly abused drugs. For most of the drugs examined chemical ionization using ammonia as the reactant gas gave the largest single m/e ion current response per unit weight of sample. However, if maximum sensitivity is desired it is important to evaluate electron impact and chemical ionization with respect to both maximum response and degree of interference from background and endogenous materials

  13. Scaling properties in single collision model of light ion reflection

    International Nuclear Information System (INIS)

    Vukanic, J.; Simovic, R.

    2004-01-01

    Light ion reflection from solids in the keV energy region has been studied within the single collision model. Particle and energy reflection coefficients as functions of the scaled transport cross section have been calculated numerically by utilizing the exact scattering function for the Kr-C potential and analytically with an effective power approximation for the same potential. The obtained analytical formulae approximate very accurately to the numerical results. Comparison of the calculated reflection coefficients with the experimental data and computer simulations for different light ion-heavy target combinations shows that the scaled transport cross section remains a convenient scaling parameter in the single collision domain, as adopted previously in multiple collision theory

  14. Single event upsets caused by solar energetic heavy ions

    International Nuclear Information System (INIS)

    Tylka, A.J.; Adams, J.H. Jr.; Boberg, P.R.; Smith, E.C.

    1996-01-01

    The authors calculate single event upset (SEU) rates due to protons, alphas, and heavier ions in two satellite systems for the major solar particle events of 1989--92, using a new and complete analysis of GOES proton data and high-energy heavy-ion fluences from the University of Chicago Cosmic Ray Telescope on IMP-8. These measurements cover the entire range of energies relevant to SEU studies and therefore overcome shortcomings of previous studies, which relied upon theoretical or semi-empirical estimates of high-energy heavy-ion spectra. They compare the results to the observed SEU rates in these events. The SEU rates in one device were overwhelmingly dominated by protons. However, even after taking into account uncertainties in the ground-test cross-section data, the authors find that at least ∼45% of the SEUs in the other device must have been caused by heavy ions. The results demonstrate that both protons and heavy ions must be considered in order to make a reliable assessment of SEU vulnerabilities. Furthermore, the GOES/Chicago database of solar particle events provides a basis for making accurate solar particle SEU calculations and credible worst-case estimates. In particular, measurements of the historic solar particle events of October 1989 are used in worst week and worst day environment models in CREME96, a revision of NRL's Cosmic Ray Effects on MicroElectronics code

  15. Conduction Mechanisms and Structure of Ionomeric Single-Ion Conductors

    Energy Technology Data Exchange (ETDEWEB)

    Colby, Ralph H. [Pennsylvania State Univ., University Park, PA (United States); Maranas, Janna K. [Pennsylvania State Univ., University Park, PA (United States); Mueller, Karl T. [Pennsylvania State Univ., University Park, PA (United States); Runt, James [Pennsylvania State Univ., University Park, PA (United States); Winey, Karen I. [Univ. of Pennsylvania, Philadelphia, PA (United States)

    2015-03-01

    Our team has designed using DFT (Gaussian) and synthesized low glass transition temperature single-ion conductors that are either polyanions that conduct small cations Li+, Na+, Cs+ or polycations that conduct small anions F-, OH-, Br-. We utilize a wide range of complimentary experimental materials characterization tools to understand ion transport; differential scanning calorimetry, dielectric relaxation spectroscopy, infrared spectroscopy, nuclear magnetic resonance spectroscopy, linear viscoelasticity, X-ray scattering and molecular dynamics simulations. The glass transition temperature Tg needs to be as low as possible to facilitate ion transport, so the nonionic parts of the polymer need to be polar, flexible and have strong solvation interactions with the ions. The lowest Tg we have managed for polyanions conducting Li+ is -60 °C. In contrast, polysiloxanes with PEO side chains and tetrabutylphosphonium cationic side groups have Tg ≈ -75 °C that barely increases with ion content, as anticipated by DFT. A survey of all polyanions in the literature suggests that Tg < -80 °C is needed to achieve the 10-4 S/cm conductivity needed for battery separators.

  16. Applications of heavy ion microprobe for single event effects analysis

    International Nuclear Information System (INIS)

    Reed, Robert A.; Vizkelethy, Gyorgy; Pellish, Jonathan A.; Sierawski, Brian; Warren, Kevin M.; Porter, Mark; Wilkinson, Jeff; Marshall, Paul W.; Niu, Guofu; Cressler, John D.; Schrimpf, Ronald D.; Tipton, Alan; Weller, Robert A.

    2007-01-01

    The motion of ionizing-radiation-induced rogue charge carriers in a semiconductor can create unwanted voltage and current conditions within a microelectronic circuit. If sufficient unwanted charge or current occurs on a sensitive node, a variety of single event effects (SEEs) can occur with consequences ranging from trivial to catastrophic. This paper describes the application of heavy ion microprobes to assist with calibration and validation of SEE modeling approaches

  17. Toward Molecular 4f Single-Ion Magnet Qubits.

    Science.gov (United States)

    Pedersen, Kasper S; Ariciu, Ana-Maria; McAdams, Simon; Weihe, Høgni; Bendix, Jesper; Tuna, Floriana; Piligkos, Stergios

    2016-05-11

    Quantum coherence is detected in the 4f single-ion magnet (SIM) Yb(trensal), by isotope selective pulsed EPR spectroscopy on an oriented single crystal. At X-band, the spin-lattice relaxation (T1) and phase memory (Tm) times are found to be independent of the nuclei bearing, or not, a nuclear spin. The observation of Rabi oscillations of the spin echo demonstrates the possibility to coherently manipulate the system for more than 70 rotations. This renders Yb(trensal), a sublimable and chemically modifiable SIM, an excellent candidate for quantum information processing.

  18. On- and off-line monitoring of ion beam treatment

    Science.gov (United States)

    Parodi, Katia

    2016-02-01

    Ion beam therapy is an emerging modality for high precision radiation treatment of cancer. In comparison to conventional radiation sources (photons, electrons), ion beams feature major dosimetric advantages due to their finite range with a localized dose deposition maximum, the Bragg peak, which can be selectively adjusted in depth. However, due to several sources of treatment uncertainties, full exploitation of these dosimetric advantages in clinical practice would require the possibility to visualize the stopping position of the ions in vivo, ideally in real-time. To this aim, different imaging methods have been proposed and investigated, either pre-clinically or even clinically, based on the detection of prompt or delayed radiation following nuclear interaction of the beam with the irradiated tissue. However, the chosen or ad-hoc developed instrumentation has often relied on technologies originally conceived for different applications, thus compromising on the achievable performances for the sake of cost-effectiveness. This contribution will review major examples of used instrumentation and related performances, identifying the most promising detector developments for next generation devices especially dedicated to on-line monitoring of ion beam treatment. Moreover, it will propose an original combination of different techniques in a hybrid detection scheme, aiming to make the most of complementary imaging methods and open new perspectives of image guidance for improved precision of ion beam therapy.

  19. Design of a single ion facility and its applications

    Energy Technology Data Exchange (ETDEWEB)

    Cholewa, M.; Saint, A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics

    1996-12-31

    The use of micro-irradiation techniques in radiobiology is not new; however, the current techniques take advantage of recent developments in particle delivery, focussing detection, image processing, cell recognition and computer control. These developments have generally come from other fields, for example microbeam elemental analysis techniques and single-event upset testing of semiconductor devices. Also in radiation biology there have been important advances in developments of individual cell assays, which allow a wide range of endpoints to be studied with good accuracy at low doses. Many of the studies that are planned involve following the responses of individual cells after a programmed exposure to charged-particle traversals. To probe the radiation sensitivity of a single cell and/or its constituents with a submicron resolution several developments are needed. The essential parameters of the proposed system can be summarised as follows: a focussed beam of ions of 300nm or less at the cell; a reliable (close to 100%) single ion detection; a fast beam switch to prevent second hits; a target holder adapted for the irradiation of wet cells and a fully automated system for cell recognition and single hits. 1 fig.

  20. Tractor performance monitor based on a single-chip microcomputer

    Energy Technology Data Exchange (ETDEWEB)

    Bedri, A.R.; Marley, S.J.; Buchelle, W.F.; Smay, T.A.

    1981-01-01

    A tractor performance monitor based on a single-chip microcomputer was developed to measure ground speed, slip, fuel consumption (rate and total), total area, theoretical time, and total time. Transducers used are presented in detail. 5 refs.

  1. In situ monitoring of polyimide windows for external ion microbeams

    International Nuclear Information System (INIS)

    Kinomura, A.; Mokuno, Y.; Chayahara, A.; Tsubouchi, N.; Horino, Y.

    2003-01-01

    Damage of polyimide windows for external ion microbeams was monitored by analyzing backscattering protons from the window. A 1.5 MeV proton microbeam focused to approximately 50 x 50 μm 2 was transmitted through the polyimide window from vacuum to oxygen atmosphere. The changes in backscattering spectra of the window were monitored as a function of irradiation dose up to 2 x 10 18 H + /cm 2 . For comparison, the polyimide window was irradiated in vacuum in the same way as the oxygen case. The backscattering spectra drastically changed in the case of oxygen. We observed that the carbon spectrum width, corresponding to the thickness of the window, substantially decreased with increasing the irradiation dose. The in situ monitoring of backscattering protons demonstrated the ability to detect the damage of the window and to predict the rupture of the window

  2. Single-chip microcomputer application in nuclear radiation monitoring instruments

    International Nuclear Information System (INIS)

    Zhang Songshou

    1994-01-01

    The single-chip microcomputer has advantage in many respects i.e. multiple function, small size, low-power consumption,reliability etc. It is widely used now in industry, instrumentation, communication and machinery. The author introduced usage of single-chip microcomputer in nuclear radiation monitoring instruments for control, linear compensation, calculation, changeable parameter presetting and military training

  3. Device for monitoring electron-ion ring parameters

    International Nuclear Information System (INIS)

    Tyutyunnikov, S.I.; Shalyapin, V.N.

    1982-01-01

    The invention is classified as the method of collective ion acceleration. The device for electron-ion ring parameters monitoring is described. The invention is aimed at increasing functional possibilities of the device at the expense of the enchance in the number of the ring controlled parameters. The device comprises three similar plane mirrors installed over accelerating tube circumference and a mirror manufactured in the form of prism and located in the tube centre, as well as the system of synchrotron radiation recording and processing. Two plane mirrors are installed at an angle of 45 deg to the vertical axis. The angle of the third plane mirror 3 α and that of prismatic mirror 2 α to the vertical axis depend on geometric parameters of the ring and accelerating tube and they are determined by the expression α=arc sin R K /2(R T -L), where R K - ring radius, R T - accelerating tube radius, L - the height of segment, formed by the mirror and inner surface of the accelerating tube. The device suggested permits to determine longitudinal dimensions of the ring, its velocity and the number of electrons and ions in the ring

  4. Single-ion quantum lock-in amplifier.

    Science.gov (United States)

    Kotler, Shlomi; Akerman, Nitzan; Glickman, Yinnon; Keselman, Anna; Ozeri, Roee

    2011-05-05

    Quantum metrology uses tools from quantum information science to improve measurement signal-to-noise ratios. The challenge is to increase sensitivity while reducing susceptibility to noise, tasks that are often in conflict. Lock-in measurement is a detection scheme designed to overcome this difficulty by spectrally separating signal from noise. Here we report on the implementation of a quantum analogue to the classical lock-in amplifier. All the lock-in operations--modulation, detection and mixing--are performed through the application of non-commuting quantum operators to the electronic spin state of a single, trapped Sr(+) ion. We significantly increase its sensitivity to external fields while extending phase coherence by three orders of magnitude, to more than one second. Using this technique, we measure frequency shifts with a sensitivity of 0.42 Hz Hz(-1/2) (corresponding to a magnetic field measurement sensitivity of 15 pT Hz(-1/2)), obtaining an uncertainty of less than 10 mHz (350 fT) after 3,720 seconds of averaging. These sensitivities are limited by quantum projection noise and improve on other single-spin probe technologies by two orders of magnitude. Our reported sensitivity is sufficient for the measurement of parity non-conservation, as well as the detection of the magnetic field of a single electronic spin one micrometre from an ion detector with nanometre resolution. As a first application, we perform light shift spectroscopy of a narrow optical quadrupole transition. Finally, we emphasize that the quantum lock-in technique is generic and can potentially enhance the sensitivity of any quantum sensor. ©2011 Macmillan Publishers Limited. All rights reserved

  5. Single-electrode monitors for relativistic intense electron beam parameters

    International Nuclear Information System (INIS)

    Stratienko, V.A.; Khorenko, V.K.

    1977-01-01

    A single-electrode monitor operating in atmosphere on delta-electrons for precision measurement of high-intensity electron beams is developed. As an emitter is used a 0.2 mm aluminium foil with a hole which is a replica of the sample subjected to radiation. The electric charge from the emitter is recorded by a current integrator. The single-electrode monitor enabled to form a 225 MeV electron beam with a flux density of 5x10 15 electrons/ (cm 2 and confine the latter for 140 hours with an accuracy of +- 0.2 mm. Controlling the beam shifting by means of the single-electrode monitor described, it is possible to measure the real dimensions and density distributions of high-intensity electron beams

  6. Photodynamic membrane damage at the level of single ion channels.

    Science.gov (United States)

    Kunz, L; Stark, G

    1997-07-05

    Illumination of cellular membranes by visible light in the presence of appropriate photosensitizers is known to inactivate specific ionic pathways and to increase the unspecific leak conductance of the membranes. While previous studies have concentrated on the macroscopic ionic currents, the present study separates the two phenomena at the microscopic level. Using opossum kidney (OK) cells as epithelial model system and photofrin II as sensitizer, the patch-clamp technique in inside-out configuration has been applied to show the inactivation of single ion channels immediately after start of illumination and the subsequent strong increase of the leak conductance. Inactivation is shown for two kinds of channels: the large-conductance Ca2+-dependent K+ channel (maxi-K(Ca)) and the stretch-activated nonselective cation channel (SA-cat).

  7. Utilization of Ion-Exclusion Chromatography for Water Quality Monitoring in a Suburban River in Jakarta, Indonesia

    Directory of Open Access Journals (Sweden)

    Daisuke Kozaki

    2014-07-01

    Full Text Available We evaluated the use of ion-exclusion chromatographic systems for analyzing the behavior of inorganic ions (e.g., bicarbonate, sulfate, chloride, nitrate, phosphate, dissolved silicate, sodium, ammonium, potassium, magnesium, and calcium ions in a suburban river located in Jakarta, Indonesia. Carbonate, phosphate, and silicate ion concentrations were determined using ion-exclusion chromatography (IEC on a weakly acidic cation-exchange resin column (WCX in the H+-form with water eluent. Other ions were identified by ion-exclusion/cation-exchange chromatography (IEC/CEC on a WCX column with tartaric acid eluent. The use of IEC systems for water quality monitoring was advantageous for the following reasons: (1 the concentrations of analyte ions, except NO3− and silicate ions, increased from upstream to downstream; and (2 the speciation of inorganic nitrogen ions could be analyzed by single injection into the IEC/CEC. The IEC approach provided beneficial information for the construction of sewage treatment facilities in our study area. Results showed that (1 the analyte concentrations for samples obtained in the downstream area were higher than those in the upstream area owing to contamination by domestic sewage; (2 the concentrations of NO3− and NH4+ correlated with the concentration of dissolved oxygen; and (3 bicarbonate concentrations increased downstream, likely due to respiration of bacteria and dissolution of concrete under low-oxygen conditions.

  8. Single-ion and single-chain magnetism in triangular spin-chain oxides

    Science.gov (United States)

    Seikh, Md. Motin; Caignaert, Vincent; Perez, Olivier; Raveau, Bernard; Hardy, Vincent

    2017-05-01

    S r4 -xC axM n2Co O9 oxides (x =0 and x =2 ) are found to exhibit magnetic responses typical of single-chain magnets (SCMs) and single-ion magnets (SIMs), two features generally investigated in coordination polymers or complexes. The compound x =0 appears to be a genuine SCM, in that blocking effects associated with slow spin dynamics yield remanence and coercivity in the absence of long-range ordering (LRO). In addition, SIM signatures of nearly identical nature are detected in both compounds, coexisting with SCM in x =0 and with LRO in x =2 . It is also observed that a SCM response can be recovered in x =2 after application of magnetic field. These results suggest that purely inorganic systems could play a valuable role in the topical issue of the interplay among SIM, SCM, and LRO phenomena in low-dimensional magnetism.

  9. Single-trial detection for intraoperative somatosensory evoked potentials monitoring.

    Science.gov (United States)

    Hu, L; Zhang, Z G; Liu, H T; Luk, K D K; Hu, Y

    2015-12-01

    Abnormalities of somatosensory evoked potentials (SEPs) provide effective evidence for impairment of the somatosensory system, so that SEPs have been widely used in both clinical diagnosis and intraoperative neurophysiological monitoring. However, due to their low signal-to-noise ratio (SNR), SEPs are generally measured using ensemble averaging across hundreds of trials, thus unavoidably producing a tardiness of SEPs to the potential damages caused by surgical maneuvers and a loss of dynamical information of cortical processing related to somatosensory inputs. Here, we aimed to enhance the SNR of single-trial SEPs using Kalman filtering and time-frequency multiple linear regression (TF-MLR) and measure their single-trial parameters, both in the time domain and in the time-frequency domain. We first showed that, Kalman filtering and TF-MLR can effectively capture the single-trial SEP responses and provide accurate estimates of single-trial SEP parameters in the time domain and time-frequency domain, respectively. Furthermore, we identified significant correlations between the stimulus intensity and a set of indicative single-trial SEP parameters, including the correlation coefficient (between each single-trial SEPs and their average), P37 amplitude, N45 amplitude, P37-N45 amplitude, and phase value (at the zero-crossing points between P37 and N45). Finally, based on each indicative single-trial SEP parameter, we investigated the minimum number of trials required on a single-trial basis to suggest the existence of SEP responses, thus providing important information for fast SEP extraction in intraoperative monitoring.

  10. On-line monitoring of heavy-ion therapy using PET

    International Nuclear Information System (INIS)

    Pavlovic, M.

    2004-01-01

    In this presentation authors present results of on-line monitoring of heavy-ion therapy using PET. It is concluded that in-beam positron emission tomography is a feasible and valuable method for in-situ and non-invasive monitoring of heavy-ion therapy

  11. Monitoring Lidocaine Single-Crystal Dissolution by Ultraviolet Imaging

    DEFF Research Database (Denmark)

    Ostergaard, Jesper; Ye, Fengbin; Rantanen, Jukka

    2011-01-01

    ) imaging for conducting single‐crystal dissolution studies was performed. Using lidocaine as a model compound, the aim was to develop a setup capable of monitoring and quantifying the dissolution of lidocaine into a phosphate buffer, pH 7.4, under stagnant conditions. A single crystal of lidocaine...... was placed in the quartz dissolution cell and UV imaging was performed at 254 nm. Spatially and temporally resolved mapping of lidocaine concentration during the dissolution process was achieved from the recorded images. UV imaging facilitated the monitoring of lidocaine concentrations in the dissolution...... media adjacent to the single crystals. The concentration maps revealed the effects of natural convection due to density gradients on the dissolution process of lidocaine. UV imaging has great potential for in vitro drug dissolution testing...

  12. In situ temperature monitoring in single-molecule FRET experiments

    Science.gov (United States)

    Hartmann, Andreas; Berndt, Frederic; Ollmann, Simon; Krainer, Georg; Schlierf, Michael

    2018-03-01

    Thermodynamic properties of single molecules including enthalpic and entropic contributions are often determined from experiments by a direct control and precise measurement of the local temperature. However, common temperature monitoring techniques using, for example, ultrafine temperature probes can lead to uncertainties as the probe cannot be placed in the vicinity of the molecule of interest. Here, we devised an approach to measure the local temperature in freely diffusing confocal single-molecule Förster Resonance Energy Transfer (smFRET) experiments in situ by directly adding the temperature-sensitive fluorescent dye Rhodamine B, whose fluorescence lifetime serves as a probe of the local temperature in the confocal volume. We demonstrate that the temperature and FRET efficiencies of static and dynamic molecules can be extracted within one measurement simultaneously, without the need of a reference chamber. We anticipate this technique to be particularly useful in the physicochemical analyses of temperature-dependent biomolecular processes from single-molecule measurements.

  13. Simultaneous Proteomic Discovery and Targeted Monitoring using Liquid Chromatography, Ion Mobility Spectrometry, and Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Burnum-Johnson, Kristin E.; Nie, Song; Casey, Cameron P.; Monroe, Matthew E.; Orton, Daniel J.; Ibrahim, Yehia M.; Gritsenko, Marina A.; Clauss, Therese R. W.; Shukla, Anil K.; Moore, Ronald J.; Purvine, Samuel O.; Shi, Tujin; Qian, Weijun; Liu, Tao; Baker, Erin S.; Smith, Richard D.

    2016-09-25

    Current proteomics approaches are comprised of both broad discovery measurements as well as more quantitative targeted measurements. These two different measurement types are used to initially identify potentially important proteins (e.g., candidate biomarkers) and then enable improved quantification for a limited number of selected proteins. However, both approaches suffer from limitations, particularly the lower sensitivity, accuracy, and quantitation precision for discovery approaches compared to targeted approaches, and the limited proteome coverage provided by targeted approaches. Herein, we describe a new proteomics approach that allows both discovery and targeted monitoring (DTM) in a single analysis using liquid chromatography, ion mobility spectrometry and mass spectrometry (LC-IMS-MS). In DTM, heavy labeled peptides for target ions are spiked into tryptic digests and both the labeled and unlabeled peptides are broadly detected using LC-IMS-MS instrumentation, allowing the benefits of discovery and targeted approaches. To understand the possible improvement of the DTM approach, it was compared to LC-MS broad measurements using an accurate mass and time tag database and selected reaction monitoring (SRM) targeted measurements. The DTM results yielded greater peptide/protein coverage and a significant improvement in the detection of lower abundance species compared to LC-MS discovery measurements. DTM was also observed to have similar detection limits as SRM for the targeted measurements indicating its potential for combining the discovery and targeted approaches.

  14. Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

    Science.gov (United States)

    McDonald, A. D.; Jones, B. J. P.; Nygren, D. R.; Adams, C.; Álvarez, V.; Azevedo, C. D. R.; Benlloch-Rodríguez, J. M.; Borges, F. I. G. M.; Botas, A.; Cárcel, S.; Carrión, J. V.; Cebrián, S.; Conde, C. A. N.; Díaz, J.; Diesburg, M.; Escada, J.; Esteve, R.; Felkai, R.; Fernandes, L. M. P.; Ferrario, P.; Ferreira, A. L.; Freitas, E. D. C.; Goldschmidt, A.; Gómez-Cadenas, J. J.; González-Díaz, D.; Gutiérrez, R. M.; Guenette, R.; Hafidi, K.; Hauptman, J.; Henriques, C. A. O.; Hernandez, A. I.; Hernando Morata, J. A.; Herrero, V.; Johnston, S.; Labarga, L.; Laing, A.; Lebrun, P.; Liubarsky, I.; López-March, N.; Losada, M.; Martín-Albo, J.; Martínez-Lema, G.; Martínez, A.; Monrabal, F.; Monteiro, C. M. B.; Mora, F. J.; Moutinho, L. M.; Muñoz Vidal, J.; Musti, M.; Nebot-Guinot, M.; Novella, P.; Palmeiro, B.; Para, A.; Pérez, J.; Querol, M.; Repond, J.; Renner, J.; Riordan, S.; Ripoll, L.; Rodríguez, J.; Rogers, L.; Santos, F. P.; dos Santos, J. M. F.; Simón, A.; Sofka, C.; Sorel, M.; Stiegler, T.; Toledo, J. F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J. F. C. A.; Webb, R.; White, J. T.; Yahlali, N.; NEXT Collaboration

    2018-03-01

    A new method to tag the barium daughter in the double-beta decay of Xe 136 is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba++ ) resolution at a transparent scanning surface is demonstrated. A single-step photobleach confirms the single ion interpretation. Individual ions are localized with superresolution (˜2 nm ), and detected with a statistical significance of 12.9 σ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double-beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.

  15. Demonstration of Single-Barium-Ion Sensitivity for Neutrinoless Double-Beta Decay Using Single-Molecule Fluorescence Imaging

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, A. D.; Jones, B. J. P.; Nygren, D. R.; Adams, C.; Álvarez, V.; Azevedo, C. D. R.; Benlloch-Rodríguez, J. M.; Borges, F. I. G. M.; Botas, A.; Cárcel, S.; Carrión, J. V.; Cebrián, S.; Conde, C. A. N.; Díaz, J.; Diesburg, M.; Escada, J.; Esteve, R.; Felkai, R.; Fernandes, L. M. P.; Ferrario, P.; Ferreira, A. L.; Freitas, E. D. C.; Goldschmidt, A.; Gómez-Cadenas, J. J.; González-Díaz, D.; Gutiérrez, R. M.; Guenette, R.; Hafidi, K.; Hauptman, J.; Henriques, C. A. O.; Hernandez, A. I.; Hernando Morata, J. A.; Herrero, V.; Johnston, S.; Labarga, L.; Laing, A.; Lebrun, P.; Liubarsky, I.; López-March, N.; Losada, M.; Martín-Albo, J.; Martínez-Lema, G.; Martínez, A.; Monrabal, F.; Monteiro, C. M. B.; Mora, F. J.; Moutinho, L. M.; Muñoz Vidal, J.; Musti, M.; Nebot-Guinot, M.; Novella, P.; Palmeiro, B.; Para, A.; Pérez, J.; Querol, M.; Repond, J.; Renner, J.; Riordan, S.; Ripoll, L.; Rodríguez, J.; Rogers, L.; Santos, F. P.; dos Santos, J. M. F.; Simón, A.; Sofka, C.; Sorel, M.; Stiegler, T.; Toledo, J. F.; Torrent, J.; Tsamalaidze, Z.; Veloso, J. F. C. A.; Webb, R.; White, J. T.; Yahlali, N.

    2018-03-01

    A new method to tag the barium daughter in the double beta decay of $^{136}$Xe is reported. Using the technique of single molecule fluorescent imaging (SMFI), individual barium dication (Ba$^{++}$) resolution at a transparent scanning surface has been demonstrated. A single-step photo-bleach confirms the single ion interpretation. Individual ions are localized with super-resolution ($\\sim$2~nm), and detected with a statistical significance of 12.9~$\\sigma$ over backgrounds. This lays the foundation for a new and potentially background-free neutrinoless double beta decay technology, based on SMFI coupled to high pressure xenon gas time projection chambers.

  16. Novel, Solvent-Free, Single Ion Conductive Polymer Electrolytes

    National Research Council Canada - National Science Library

    Florjanczyk, Zbigniew

    2008-01-01

    This project report concerns studies on the synthesis of new polymer electrolytes for application in lithium and lithium-ion batteries characterized by limited participation of anions in the transport...

  17. Correlation of precursor and product ions in single-stage high resolution mass spectrometry. A tool for detecting diagnostic ions and improving the precursor elemental composition elucidation

    Energy Technology Data Exchange (ETDEWEB)

    Borràs, S. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain); Kaufmann, A., E-mail: anton.kaufmann@klzh.ch [Official Food Control Authority, Fehrenstrasse 15, 8032 Zürich (Switzerland); Companyó, R. [Departament de Química Analítica, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona (Spain)

    2013-04-15

    Highlights: ► We are describing a technique to spot ions which are derived from each other. ► Single stage high resolution data is used. ► This “in silicon” technique is compared to conventional precursor scan. ► Some applications for this technique are presented. -- Abstract: Monitoring of common diagnostic fragments is essential for recognizing molecules which are members of a particular compound class. Up to now, unit resolving tandem quadrupole mass spectrometers, operating in the precursor ion scan mode, have been typically used to perform such analysis. By means of high-resolution mass spectrometry (HRMS) a much more sensitive and selective detection can be achieved. However, using a single-stage HRMS instrument, there is no unequivocal link to the corresponding precursor ion, since such instrumentation does not permit a previous precursor selection. Thus, to address this limitation, an in silico approach to locate precursor ions, based on diagnostic fragments, was developed. Implemented as an Excel macro, the algorithm rapidly assembles and surveys exact mass data to provide a list of feasible precursor candidates according to the correlation of the chromatographic peak shape profile and other additional filtering criteria (e.g. neutral losses and isotopes). The macro was tested with two families of veterinary drugs, sulfonamides and penicillins, which are known to yield diagnostic product ions when fragmented. Data sets obtained from different food matrices (fish and liver), both at high and low concentration of the target compounds, were investigated in order to evaluate the capabilities and limitations of the reported approach. Finally, other possible applications of this technique, such as the elucidation of elemental compositions based on product ions and corresponding neutral losses, were also presented and discussed.

  18. Features of polyatomic ion emission under sputtering of a silicon single crystal by Au sub m sup - cluster ions

    CERN Document Server

    Akhunov, S; Rasulev, U K

    2003-01-01

    Comparative studies of the emission of secondary cluster Si sub n sup + ions (n=1-11) and polyatomic Si sub n X sub l Y sub k sup + ions (X, Y are Au, B, C, N), as well as doubly charged Si sup 2 sup + ions under bombardment of single crystalline silicon by cluster Au sub m sup - (m=1-5) ions with energy E sub 0 =4-18 keV have been carried out. High non-additivity enhancement of the yield of the Si sub n sup + ions and most polyatomic ones has been observed with an increase of the number of atoms in the projectiles. For Si sup 2 sup + ions the negative non-additive effect has been observed. The increase in the yield of impurity-containing cluster Si sub n X sup + ions allows for an increase by a factor of 100-1000 for the sensitivity of the SIMS analysis of the Au, B, C, N impurities in Si with the use of cluster ions as primary and secondary ones.

  19. Development of a keV single-ion-implanter for nanofabrication

    International Nuclear Information System (INIS)

    Yang, C.; Jamieson, D.N.; Hopf, T.; Tamanyan, G.; Spizziri, P.; Pakes, C.; Andresen, S.E.; Hudson, F.; Gauja, E.; Dzurak, A.; Clark, R.G.

    2005-01-01

    Traditional methods of doping semiconductors have a difficulty meeting the demand for high precision doping due to large statistical fluctuations in the numbers of dopant atoms introduced in the ever shrinking volume in micro- and nano-electronics devices, especially when the fabrication process approaches the nanometre scale. The statistical fluctuations in doping semiconductors for the fabrication of devices with a very small feature size may lead to inconsistent and unreliable performance. This paper describes the adaptation of a commercial ion implanter into a single-ion-implantation system for the accurate delivery of dopants into a nanometre or micrometre area in a silicon substrate. All the implanted ions can be accurately counted with near 100% certainty through online detection using the silicon substrate itself as an ion detector. A variety of ion species including B + , N + , P + at the energy range of 10-15 keV can be delivered in the single ion implantation system. (author). 6 refs., 6 figs

  20. Optimization of ECR singly-charged ion sources for the radioactive ion beam production

    CERN Document Server

    Jardin, P; Gaubert, G; Pacquet, J Y; Drobert, T; Cornell, J; Barue, C; Canet, C; Dupuis, M; Flambard, J L; Lecesne, N; Leherissier, P; Lemagnen, F; Leroy, R

    2003-01-01

    Measurements of the transformation time of atoms into ions were carried out with two 2.45 GHz electron cyclotron resonance ion sources (ECRIS) in the case of the simple ionization of He, Ne, Ar and Kr gases. The effect of the plasma volume, of the dead volumes and of the ionization efficiency are presented. Some rules are deduced for the design of the next ECRIS dedicated to radioactive ion production with noble gases.

  1. Ion beam induced single phase nanocrystalline TiO2 formation

    Science.gov (United States)

    Rukade, Deepti A.; Tribedi, L. C.; Bhattacharyya, Varsha

    2014-06-01

    Single phase TiO2 nanostructures are fabricated by oxygen ion implantation (60 keV) at fluence ranging from 1×1016 ions/cm2 to 1×1017 ions/cm2 in titanium thin films deposited on fused silica substrate and subsequent thermal annealing in argon atmosphere. GAXRD and Raman spectroscopy study reveals formation of single rutile phases of TiO2. Particle size is found to vary from 29 nm to 35 nm, establishing nanostructure formation. Nanostructure formation is also confirmed by the quantum confinement effect manifested by the blueshift of the UV-vis absorption spectra. Photoluminescence spectra show peaks corresponding to TiO2 rutile phase and reveal the presence of oxygen defects due to implantation. The controlled synthesis of single phase nanostructure is attributed to ion induced defects and post-implantation annealing. It is observed that the size of the nanostructures formed is strongly dependent on the ion fluence.

  2. Development of heavy-ion irradiation technique for single-event in semiconductor devices

    Energy Technology Data Exchange (ETDEWEB)

    Nemoto, Norio; Akutsu, Takao; Matsuda, Sumio [National Space Development Agency of Japan, Tsukuba, Ibaraki (Japan). Tsukuba Space Center; Naitoh, Ichiro; Itoh, Hisayoshi; Agematsu, Takashi; Kamiya, Tomihiro; Nashiyama, Isamu

    1997-03-01

    Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

  3. Action of age-hardening on the copper single crystals after ion implantation

    International Nuclear Information System (INIS)

    Kul'ment'eva, O.P.; Kul'ment'ev, A.I.

    2007-01-01

    High-dose implantation (up to (1-5)·10 17 cm -2 ) of tantalum ions into a copper single crystal of (100), (110) and (111) orientation has been investigated. Modified properties just after ion implantation and subsequent age-hardening during ten years were studied. It was shown that ion implantation and subsequent masstransfer process results in sufficient long-term stable changes of the microhardness. (authors)

  4. Real-Time Online Monitoring of the Ion Range by Means of Prompt Secondary Radiations

    International Nuclear Information System (INIS)

    Krimmer, J.; Balleyguier, L.; Caponetto, L.; Chen, X.; Dahoumane, M.; Dauvergne, D.; De Rydt, M.; Dedes, G.; Della Negra, R.; Deng, S.M.; Ley, J.L.; Mathez, H.; Pinto, M.; Ray, C.; Richard, M.H.; Reithinger, V.; Roellinghoff, F.; Testa, E.; Zoccarato, Y.; Baudot, J.; Winter, M.; Brons, S.; Chabot, M.; Force, P.; Joly, B.; Insa, C.; Lambert, D.; Lestand, L.; Magne, M.; Montarou, G.; Freud, N.; Letang, J.M.; Lojacono, X.; Maxim, V.; Prostk, R.; Herault, J.; La Tessa, C.; Pleskac, R.; Vanstalle, M.; Parodi, K.; Prieels, D.; Smeets, J.; Rinaldi, I.

    2013-06-01

    Prompt secondary radiations such as gamma rays and protons can be used for ion-range monitoring during ion therapy either on an energy-slice basis or on a pencil-beam basis. We present a review of the ongoing activities in terms of detector developments, imaging, experimental and theoretical physics issues concerning the correlation between the physical dose and hadronic processes. (authors)

  5. Production of multi-, oligo- and single-pore membranes using a continuous ion beam

    Czech Academy of Sciences Publication Activity Database

    Apel, P. Yu.; Ivanov, O.; Lizunov, N. E.; Mamonova, T. I.; Nechaev, A. N.; Olejniczak, K.; Vacík, Jiří; Dmitriev, S. N.

    2015-01-01

    Roč. 365, DEC (2015), s. 641-645 ISSN 0168-583X R&D Projects: GA MŠk LG14004 Institutional support: RVO:61389005 Keywords : ion beam * irradiation * ion track * etching * single nanopore Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders Impact factor: 1.389, year: 2015

  6. Lattice location of platinum ions implanted into single crystal zirconia and their annealing behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Cao, D.X. [Royal Melbourne Inst. of Tech., VIC (Australia); Sood, D.K. [Academia Sinica, Shanghai, SH (China). Shanghai Inst. of Nuclear Research; Brown, I.G. [Lawrence Berkeley Lab., CA (United States)

    1993-12-31

    Single crystal samples of (100) oriented cubic zirconia stabilised with 9.5 mol % yttria were implanted with platinum ions, using a metal vapour vacuum arc (MEVVA) high current ion implanter, to a nominal dose of 1x10{sup 17} ions/cm{sup 2}. The implanted samples were annealed isothermally in air ambient at 1200 deg C, from 1-24 hours. Rutherford Backscattering Spectrometry and Channeling (RBSC) of 2 MeV He ions are employed to determine depth distributions of ion damage, Pt ions and substitutionality of Pt ions before and after annealing. The damage behaviour, Pt migration and lattice location are discussed in terms of metastable phase formation and solid solubility considerations. 7 refs., 3 figs.

  7. Single ion induced surface nanostructures: a comparison between slow highly charged and swift heavy ions.

    Science.gov (United States)

    Aumayr, Friedrich; Facsko, Stefan; El-Said, Ayman S; Trautmann, Christina; Schleberger, Marika

    2011-10-05

    This topical review focuses on recent advances in the understanding of the formation of surface nanostructures, an intriguing phenomenon in ion-surface interaction due to the impact of individual ions. In many solid targets, swift heavy ions produce narrow cylindrical tracks accompanied by the formation of a surface nanostructure. More recently, a similar nanometric surface effect has been revealed for the impact of individual, very slow but highly charged ions. While swift ions transfer their large kinetic energy to the target via ionization and electronic excitation processes (electronic stopping), slow highly charged ions produce surface structures due to potential energy deposited at the top surface layers. Despite the differences in primary excitation, the similarity between the nanostructures is striking and strongly points to a common mechanism related to the energy transfer from the electronic to the lattice system of the target. A comparison of surface structures induced by swift heavy ions and slow highly charged ions provides a valuable insight to better understand the formation mechanisms. © 2011 IOP Publishing Ltd

  8. Secondary electron emission from boron-doped diamond under ion impact: Applications in single-ion detection

    International Nuclear Information System (INIS)

    Kamiya, T.; Cholewa, M.; Saint, A.; Prawer, S.; Legge, G.J.; Butler, J.E.; Vestyck, D.J. , Jr.

    1997-01-01

    The secondary electron emission from a 2 μm thick boron-doped diamond film under ion (4.6 endash 7.7 MeV He + )impact is reported. The yield under ions impact is found to be remarkably high, stable over a period of many months, and independent of which side of the film (i.e., growth or substrate side) is exposed to the ion flux. By taking advantage of the high secondary-electron yield, the passage of each ion through the film could be detected with an efficiency of close to 100%, which to the best of our knowledge is the highest efficiency recorded to date for any thin-film window. This finding has an immediate application in single-ion irradiation systems where a thin vacuum window is required to allow extraction of an ion beam from the vacuum into air and at the same time offer 100% efficiency for the detection of the passage of the ion through the window. copyright 1997 American Institute of Physics

  9. Scanning probe microscopy of single Au ion implants in Si

    International Nuclear Information System (INIS)

    Vines, L.; Monakhov, E.; Maknys, K.; Svensson, B.G.; Jensen, J.; Hallen, A.; Kuznetsov, A. Yu.

    2006-01-01

    We have studied 5 MeV Au 2+ ion implantation with fluences between 7 x 10 7 and 2 x 10 8 cm -2 in Si by deep level transient spectroscopy (DLTS) and scanning capacitance microscopy (SCM). The DLTS measurements show formation of electrically active defects such as the two negative charge states of the divacancy (V 2 (=/-) and V 2 (-/0)) and the vacancy-oxygen (VO) center. It is observed that the intensity of the V 2 (=/-) peak is lower compared to that of V 2 (-/0) by a factor of 5. This has been attributed to a highly localized distribution of the defects along the ion tracks, which results in trapping of the carriers at V 2 (-/0) and incomplete occupancy of V 2 (=/-). The SCM measurements obtained in a plan view show a random pattern of regions with a reduced SCM signal for the samples implanted with fluence above 2 x 10 8 cm -2 . The reduced SCM signal is attributed to extra charges associated with acceptor states, such as V 2 (-/0), formed along the ion tracks in the bulk Si. Indeed, the electron emission rate from the V 2 (-/0) state is in the range of 10 kHz at room temperature, which is well below the probing frequency of the SCM measurements, resulting in 'freezing' of electrons at V 2 (-/0)

  10. A simple and rapid method for high-resolution visualization of single-ion tracks

    Directory of Open Access Journals (Sweden)

    Masaaki Omichi

    2014-11-01

    Full Text Available Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA-N, N’-methylene bisacrylamide (MBAAm blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.

  11. Network type sp3 boron-based single-ion conducting polymer electrolytes for lithium ion batteries

    Science.gov (United States)

    Deng, Kuirong; Wang, Shuanjin; Ren, Shan; Han, Dongmei; Xiao, Min; Meng, Yuezhong

    2017-08-01

    Electrolytes play a vital role in modulating lithium ion battery performance. An outstanding electrolyte should possess both high ionic conductivity and unity lithium ion transference number. Here, we present a facile method to fabricate a network type sp3 boron-based single-ion conducting polymer electrolyte (SIPE) with high ionic conductivity and lithium ion transference number approaching unity. The SIPE was synthesized by coupling of lithium bis(allylmalonato)borate (LiBAMB) and pentaerythritol tetrakis(2-mercaptoacetate) (PETMP) via one-step photoinitiated in situ thiol-ene click reaction in plasticizers. Influence of kinds and content of plasticizers was investigated and the optimized electrolytes show both outstanding ionic conductivity (1.47 × 10-3 S cm-1 at 25 °C) and high lithium transference number of 0.89. This ionic conductivity is among the highest ionic conductivity exhibited by SIPEs reported to date. Its electrochemical stability window is up to 5.2 V. More importantly, Li/LiFePO4 cells with the prepared single-ion conducting electrolytes as the electrolyte as well as the separator display highly reversible capacity and excellent rate capacity under room temperature. It also demonstrates excellent long-term stability and reliability as it maintains capacity of 124 mA h g-1 at 1 C rate even after 500 cycles without obvious decay.

  12. A large area diamond-based beam tagging hodoscope for ion therapy monitoring

    Science.gov (United States)

    Gallin-Martel, M.-L.; Abbassi, L.; Bes, A.; Bosson, G.; Collot, J.; Crozes, T.; Curtoni, S.; Dauvergne, D.; De Nolf, W.; Fontana, M.; Gallin-Martel, L.; Hostachy, J.-Y.; Krimmer, J.; Lacoste, A.; Marcatili, S.; Morse, J.; Motte, J.-F.; Muraz, J.-F.; Rarbi, F. E.; Rossetto, O.; Salomé, M.; Testa, É.; Vuiart, R.; Yamouni, M.

    2018-01-01

    The MoniDiam project is part of the French national collaboration CLaRyS (Contrôle en Ligne de l'hAdronthérapie par RaYonnements Secondaires) for on-line monitoring of hadron therapy. It relies on the imaging of nuclear reaction products that is related to the ion range. The goal here is to provide large area beam detectors with a high detection efficiency for carbon or proton beams giving time and position measurement at 100 MHz count rates (beam tagging hodoscope). High radiation hardness and intrinsic electronic properties make diamonds reliable and very fast detectors with a good signal to noise ratio. Commercial Chemical Vapor Deposited (CVD) poly-crystalline, heteroepitaxial and monocrystalline diamonds were studied. Their applicability as a particle detector was investigated using α and β radioactive sources, 95 MeV/u carbon ion beams at GANIL and 8.5 keV X-ray photon bunches from ESRF. This facility offers the unique capability of providing a focused ( 1 μm) beam in bunches of 100 ps duration, with an almost uniform energy deposition in the irradiated detector volume, therefore mimicking the interaction of single ions. A signal rise time resolution ranging from 20 to 90 ps rms and an energy resolution of 7 to 9% were measured using diamonds with aluminum disk shaped surface metallization. This enabled us to conclude that polycrystalline CVD diamond detectors are good candidates for our beam tagging hodoscope development. Recently, double-side stripped metallized diamonds were tested using the XBIC (X Rays Beam Induced Current) set-up of the ID21 beamline at ESRF which permits us to evaluate the capability of diamond to be used as position sensitive detector. The final detector will consist in a mosaic arrangement of double-side stripped diamond sensors read out by a dedicated fast-integrated electronics of several hundreds of channels.

  13. The method and equipment for the investigation of ions orienting transmission through thin single crystals

    CERN Document Server

    Soroka, V Y; Maznij, Y O

    2003-01-01

    A new approach is proposed to solve the task of angular distribution measurement of intensity strongly differentiated ions fluxes. Channeling effect makes this problem a regular feature of experimental study of ions orientating transmission through thin single crystals. The approach is based on the use of ions additional scattering by an amorphous (polycrystalline) target after passing through single crystal. The additional target manipulator is joined with the principal target chamber equipment with three-axis goniometer. The manipulator allows to move an additional target in the vicinity of the accelerator beam within the limits of +- 3 sup 0 in all directions and allows to measure the angular distribution of scattered ions with the accuracy of 1 min. The method and equipment were tested at the single ended electrostatic accelerator (EG-5) using a proton beam. At present the measurements have been resumed at the tandem accelerator (EG-10) of the Institute for Nuclear Research of the Academy of Sciences of U...

  14. Non-invasive monitoring of therapeutic carbon ion beams in a homogeneous phantom by tracking of secondary ions

    Science.gov (United States)

    Gwosch, K.; Hartmann, B.; Jakubek, J.; Granja, C.; Soukup, P.; Jäkel, O.; Martišíková, M.

    2013-06-01

    Radiotherapy with narrow scanned carbon ion beams enables a highly accurate treatment of tumours while sparing the surrounding healthy tissue. Changes in the patient’s geometry can alter the actual ion range in tissue and result in unfavourable changes in the dose distribution. Consequently, it is desired to verify the actual beam delivery within the patient. Real-time and non-invasive measurement methods are preferable. Currently, the only technically feasible method to monitor the delivered dose distribution within the patient is based on tissue activation measurements by means of positron emission tomography (PET). An alternative monitoring method based on tracking of prompt secondary ions leaving a patient irradiated with carbon ion beams has been previously suggested. It is expected to help in overcoming the limitations of the PET-based technique like physiological washout of the beam induced activity, low signal and to allow for real-time measurements. In this paper, measurements of secondary charged particle tracks around a head-sized homogeneous PMMA phantom irradiated with pencil-like carbon ion beams are presented. The investigated energies and beam widths are within the therapeutically used range. The aim of the study is to deduce properties of the primary beam from the distribution of the secondary charged particles. Experiments were performed at the Heidelberg Ion Beam Therapy Center, Germany. The directions of secondary charged particles emerging from the PMMA phantom were measured using an arrangement of two parallel pixelated silicon detectors (Timepix). The distribution of the registered particle tracks was analysed to deduce its dependence on clinically important beam parameters: beam range, width and position. Distinct dependencies of the secondary particle tracks on the properties of the primary carbon ion beam were observed. In the particular experimental set-up used, beam range differences of 1.3 mm were detectable. In addition, variations

  15. A novel aptasensor based on single-molecule force spectroscopy for highly sensitive detection of mercury ions.

    Science.gov (United States)

    Li, Qing; Michaelis, Monika; Wei, Gang; Colombi Ciacchi, Lucio

    2015-08-07

    We have developed a novel aptasensor based on single-molecule force spectroscopy (SMFS) capable of detecting mercury ions (Hg(2+)) with sub-nM sensitivity. The single-strand (ss) DNA aptamer used in this work is rich in thymine (T) and readily forms T-Hg(2+)-T complexes in the presence of Hg(2+). The aptamer was conjugated to an atomic force microscope (AFM) probe, and the adhesion force between the probe and a flat graphite surface was measured by single-molecule force spectroscopy (SMFS). The presence of Hg(2+) ions above a concentration threshold corresponding to the affinity constant of the ions for the aptamer (about 5 × 10(9) M(-1)) could be easily detected by a change of the measured adhesion force. With our chosen aptamer, we could reach an Hg(2+) detection limit of 100 pM, which is well below the maximum allowable level of Hg(2+) in drinking water. In addition, this aptasensor presents a very high selectivity for Hg(2+) over other metal cations, such as K(+), Ca(2+), Zn(2+), Fe(2+), and Cd(2+). Furthermore, the effects of the ionic strength and loading rate on the Hg(2+) detection were evaluated. Its simplicity, reproducibility, high selectivity and sensitivity make our SMFS-based aptasensor advantageous with respect to other current Hg(2+) sensing methods. It is expected that our strategy can be exploited for monitoring the pollution of water environments and the safety of potentially contaminated food.

  16. Most spin-1/2 transition-metal ions do have single ion anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jia; Whangbo, Myung-Hwan, E-mail: hxiang@fudan.edu.cn, E-mail: mike-whangbo@ncsu.edu [Department of Chemistry, North Carolina State University, Raleigh, North Carolina 27695 (United States); Koo, Hyun-Joo [Department of Chemistry and Research Institute for Basic Sciences, Kyung Hee University, Seoul 130-701 (Korea, Republic of); Xiang, Hongjun, E-mail: hxiang@fudan.edu.cn, E-mail: mike-whangbo@ncsu.edu [Key Laboratory of Computational Physical Sciences (Ministry of Education), State Key Laboratory of Surface Physics, and Department of Physics, Fudan University, Shanghai 200433 (China); Kremer, Reinhard K. [Max-Planck-Institut für Festkörperforschung, Heisenbergstrasse 1, D-70569 Stuttgart (Germany)

    2014-09-28

    The cause for the preferred spin orientation in magnetic systems containing spin-1/2 transition-metal ions was explored by studying the origin of the easy-plane anisotropy of the spin-1/2 Cu{sup 2+} ions in CuCl{sub 2}·2H{sub 2}O, LiCuVO{sub 4}, CuCl{sub 2}, and CuBr{sub 2} on the basis of density functional theory and magnetic dipole-dipole energy calculations as well as a perturbation theory treatment of the spin-orbit coupling. We find that the spin orientation observed for these spin-1/2 ions is not caused by their anisotropic spin exchange interactions, nor by their magnetic dipole-dipole interactions, but by the spin-orbit coupling associated with their crystal-field split d-states. Our study also predicts in-plane anisotropy for the Cu{sup 2+} ions of Bi{sub 2}CuO{sub 4} and Li{sub 2}CuO{sub 2}. The results of our investigations dispel the mistaken belief that magnetic systems with spin-1/2 ions have no magnetic anisotropy induced by spin-orbit coupling.

  17. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Hyojae, E-mail: lkcom@ibs.re.kr; Jin, Hyunchang; Jang, Ji-Ho; Hong, In-Seok [Rare Isotope Science Project, Institute for Basic Science, Daejeon (Korea, Republic of)

    2016-02-15

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

  18. Single photons, dileptons and hadrons from relativistic heavy ion ...

    Indian Academy of Sciences (India)

    The production of single photons in Pb+Pb collisions at the CERN SPS as measured by the WA98 experiment is analysed. A quark gluon plasma is assumed to be formed initially, which expands, cools, hadronizes, and undergoes freeze-out. A rich hadronic equation of state is used and the transverse expansion of the ...

  19. Single photons, dileptons and hadrons from relativistic heavy ion ...

    Indian Academy of Sciences (India)

    Abstract. The production of single photons in Pb+Pb collisions at the CERN SPS as measured by the WA98 experiment is analysed. A quark gluon plasma is assumed to be formed initially, which expands, cools, hadronizes, and undergoes freeze-out. A rich hadronic equation of state is used and the transverse expansion of ...

  20. Single event simulation for memories using accelerated ions

    International Nuclear Information System (INIS)

    Sakagawa, Y.; Shiono, N.; Mizusawa, T.; Sekiguchi, M.; Sato, K.; Sugai, I.; Hirao, Y.; Nishimura, J.; Hattori, T.

    1987-01-01

    To evaluate the error immunity of the LSI memories from cosmic rays in space, an irradiation test using accelerated heavy ions is performed. The sensitive regions for 64 K DRAM (Dynamic Random Access Memory) and 4 K SRAM (Static Random Access Memory) are determined from the irradiation test results and the design parameters of the devices. The observed errors can be classified into two types. One is the direct ionization type and the other is the recoil produced error type. Sensitive region is determined for the devices. Error rate estimation methods for both types are proposed and applied to those memories used in space. The error rate of direct ionization exceeds the recoil type by 2 or 3 orders. And the direct ionization is susceptible to shield thickness. (author)

  1. Single event effects induced by 15.14 MeV/u 136Xe ions

    International Nuclear Information System (INIS)

    Hou Mingdong; Zhang Qingxiang; Liu Jie; Wang Zhiguang; Jin Yunfan; Zhu Zhiyong; Zhen Honglou; Liu Changlong; Chen Xiaoxi; Wei Xinguo; Zhang Lin; Fan Youcheng; Zhu Zhourong; Zhang Yiting

    2002-01-01

    Single event effects induced by 15.14 MeV/u 136 Xe ions in different batches of 32k x 8 bits static random access memory are studied. The incident angle dependences of the cross sections for single event upset and single event latch up are presented. The SEE cross sections are plotted versus energy loss instead of linear energy transfer value in sensitive region. The depth of sensitive volume and thickness of 'dead' layer above the sensitive volume are estimated

  2. Imaging large cohorts of single ion channels and their activity

    Directory of Open Access Journals (Sweden)

    Katia eHiersemenzel

    2013-09-01

    Full Text Available As calcium is the most important signaling molecule in neurons and secretory cells, amongst many other cell types, it follows that an understanding of calcium channels and their regulation of exocytosis is of vital importance. Calcium imaging using calcium dyes such as Fluo3, or FRET-based dyes that have been used widely has provided invaluable information, which combined with modeling has estimated the sub-types of channels responsible for triggering the exocytotic machinery as well as inferences about the relative distances away from vesicle fusion sites these molecules adopt. Importantly, new super-resolution microscopy techniques, combined with novel Ca2+ indicators and imaginative imaging approaches can now define directly the nanoscale locations of very large cohorts of single channel molecules in relation to single vesicles. With combinations of these techniques the activity of individual channels can be visualized and quantified using novel Ca2+ indicators. Fluorescently labeled specific channel toxins can also be used to localize endogenous assembled channel tetramers. Fluorescence lifetime imaging microscopy and other single-photon-resolution spectroscopic approaches offer the possibility to quantify protein-protein interactions between populations of channels and the SNARE protein machinery for the first time. Together with simultaneous electrophysiology, this battery of quantitative imaging techniques has the potential to provide unprecedented detail describing the locations, dynamic behaviours, interactions and conductance activities of many thousands of channel molecules and vesicles in living cells.

  3. A Single Bremsstrahlung Monitor to Measure Luminosity at LEP

    CERN Multimedia

    2002-01-01

    The luminosity, the beam divergence and the longitudinal polarization can be measured at an interaction point of LEP by dectecting the energy, the angular distribution and the circular polarization of the single bremsstrahlung photons (SB) emitted at very forward angle. The luminosity can be measured by this met than by the conventional method of detecting small angle Bhabha scattering. The bunch to bunch relative luminosity can be monitored at a few per mil level in few minutes. Absolute values of the luminosity and of the polarization can be measured with a precision of the order of 1\\%. \\\\ \\\\ The apparatus to detect SB photons consists of a low Z absorber and of an EM calorimeter made of lead and scintillating fibres. Both the total energy and the space distribution of the SB photons are measured. This apparatus has been designed and built at the Department of Physics and INFN Section of the University of Rome ``La Sapienza''. Later on, together with suitable monocrystal converters, it may be used also for...

  4. In Situ Monitoring of Temperature inside Lithium-Ion Batteries by Flexible Micro Temperature Sensors

    Directory of Open Access Journals (Sweden)

    Pei-Chi Chen

    2011-10-01

    Full Text Available Lithium-ion secondary batteries are commonly used in electric vehicles, smart phones, personal digital assistants (PDA, notebooks and electric cars. These lithium-ion secondary batteries must charge and discharge rapidly, causing the interior temperature to rise quickly, raising a safety issue. Over-charging results in an unstable voltage and current, causing potential safety problems, such as thermal runaways and explosions. Thus, a micro flexible temperature sensor for the in in-situ monitoring of temperature inside a lithium-ion secondary battery must be developed. In this work, flexible micro temperature sensors were integrated into a lithium-ion secondary battery using the micro-electro-mechanical systems (MEMS process for monitoring temperature in situ.

  5. In situ monitoring of temperature inside lithium-ion batteries by flexible micro temperature sensors.

    Science.gov (United States)

    Lee, Chi-Yuan; Lee, Shuo-Jen; Tang, Ming-Shao; Chen, Pei-Chi

    2011-01-01

    Lithium-ion secondary batteries are commonly used in electric vehicles, smart phones, personal digital assistants (PDA), notebooks and electric cars. These lithium-ion secondary batteries must charge and discharge rapidly, causing the interior temperature to rise quickly, raising a safety issue. Over-charging results in an unstable voltage and current, causing potential safety problems, such as thermal runaways and explosions. Thus, a micro flexible temperature sensor for the in in-situ monitoring of temperature inside a lithium-ion secondary battery must be developed. In this work, flexible micro temperature sensors were integrated into a lithium-ion secondary battery using the micro-electro-mechanical systems (MEMS) process for monitoring temperature in situ.

  6. Laser spectroscopic investigation of singly and doubly charged thorium ions

    Energy Technology Data Exchange (ETDEWEB)

    Thielking, Johannes; Meier, David-Marcel; Glowacki, Przemyslaw; Okhapkin, Maksim V.; Peik, Ekkehard [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    2017-07-01

    The {sup 229}Th isotope possesses a unique, low-energy nuclear isomeric state at about 7.8(5) eV. This fact has stimulated the development of novel ideas in the borderland between atomic and nuclear physics, for example the use as an optical nuclear clock. Since the required precise information on the isomer energy is not yet available, it is intensely searched for using different experimental approaches. For the excitation of the nuclear isomer via electronic bridge or NEET processes, we plan to use two-photon laser excitation of high-lying electronic levels in Th{sup +}. We recently expanded our search range to higher energies and measured 38 previously unknown energy levels in the range from 7.8 eV to 8.7 eV. We also prepare to study the nuclear structure of the isomeric state in cooperation with the Maier-Leibnitz-Laboratorium at LMU Munich, using trapped recoil ions, where the isomeric state is populated via α-decay from {sup 233}U. For this purpose we investigate the hyperfine structure of suitable transitions of Th{sup 2+}.

  7. Transmission of Fast Highly Charged Ions through a Single Glass Macrocapillary and Polycarbonate Nanocapillary Foils

    Science.gov (United States)

    Ayyad, A. M.; Dassanayake, B. S.; Keerthisinghe, D.; DeSilva, G. G.; Elkafrawy, T.; Kayani, N.; Tanis, J. A.

    2012-11-01

    Transmission of 3 MeV protons and 16 MeV O5+ ions through a single glass macrocapillary and a polycarbonate nanocapillary foil has been investigated. Results show that 3 MeV protons transmit through the capillary and the foils with little or no energy loss, while 16 MeV O5+ ions show transmission through the capillary and the foil with energy losses that vary with the tilt angle, and there are also changes in the charge state.

  8. Characterization of strained InGaAs single quantum well structures by ion beam methods

    International Nuclear Information System (INIS)

    Yu, K.M.; Chan, K.T.

    1990-01-01

    We have investigated strained InGaAs single quantum well structures using MeV ion beam methods. The structural properties of these structures, including composition and well size, have been studied. It has been found that the composition obtained by Rutherford backscattering spectrometry and particle-induced x-ray emission techniques agrees very well with that obtained by the ion channeling method

  9. Air Quality Monitoring with Routine Utilization of Ion Beam Analysis

    International Nuclear Information System (INIS)

    Wegrzynek, D.

    2013-01-01

    Full text: Information on source contributions to ambient air particulate concentrations is a vital tool for air quality management. Traditional gravimetric analysis of airborne particulate matter is unable to provide information on the sources contributing to air particulate concentrations. Ion beam analysis is used to identify the elemental composition of air particulates for source apportionment and determining the relative contribution of biogenic and anthropogenic sources to air particulate pollution. The elemental composition is obtained by proton induced X-ray emission technique (PIXE), which is an ion beam analysis (IBA) technique. The element concentrations are deduced from the X ray spectra produced when the particulate collected on a filter is bombarded with a high-energy proton beam. As part of the UNDP/IAEA/RCA Project RAS/8/082 ‘Better Management of the Environment, Natural Resources and Industrial Growth through Isotope and Radiation Technology,’ a collaborative alliance was formed between the Institute of Geological and Nuclear Sciences Limited and the Wellington Regional Council, New Zeland [1]. The purpose of the project was to examine the elemental composition of air particulate matter and determine the origins through source apportionment techniques. In New Zealand PM 10 and PM 2.5 fractions have been collected at the industrial area of Seaview, Wellington over two years using a GENT stacked filter unit sampler. Concentrations of elements with atomic mass above neon were determined using ion beam analysis and elemental carbon concentrations were determined using a reflectometer. Specific ambient source elemental 'fingerprints' were then determined by factor analysis and the relative contributions of various local and regional sources were assessed. The significant factors (sources) were determined to be sea salt, soil, industry, and combustion sources. Local industry was found to contribute to ambient lead concentrations. (author)

  10. Effect of 120 MeV Ag9+ ion irradiation of YCOB single crystals

    Science.gov (United States)

    Arun Kumar, R.; Dhanasekaran, R.

    2012-09-01

    Single crystals of yttrium calcium oxy borate (YCOB) grown from boron-tri-oxide flux were subjected to swift heavy ion irradiation using silver Ag9+ ions from the 15 UD Pelletron facility at Inter University Accelerator Center, New Delhi. The crystals were irradiated at 1 × 1013, 5 × 1013 and 1 × 1014 ions/cm2 fluences at room temperature and with 5 × 1013 ions/cm2 fluence at liquid nitrogen temperature. The pristine and the irradiated samples were characterized by glancing angle X-ray diffraction, UV-Vis-NIR and photoluminescence studies. From the characterization studies performed on the samples, it is inferred that the crystals irradiated at liquid nitrogen temperature had fewer defects compared to the crystals irradiated at room temperature and the defects increased when the ion fluence was increased at room temperature.

  11. Potentiometric Sensor for Real-Time Monitoring of Multivalent Ion Concentrations in Molten Salt

    Energy Technology Data Exchange (ETDEWEB)

    Peter A. Zink; Jan-Fong Jue; Brenda E. Serrano; Guy L. Fredrickson; Ben F. Cowan; Steven D. Herrmann; Shelly X. Li

    2010-07-01

    Electrorefining of spent metallic nuclear fuel in high temperature molten salt systems is a core technology in pyroprocessing, which in turn plays a critical role in the development of advanced fuel cycle technologies. In electrorefining, spent nuclear fuel is treated electrochemically in order to effect separations between uranium, noble metals, and active metals, which include the transuranics. The accumulation of active metals in a lithium chloride-potassium chloride (LiCl-KCl) eutectic molten salt electrolyte occurs at the expense of the UCl3-oxidant concentration in the electrolyte, which must be periodically replenished. Our interests lie with the accumulation of active metals in the molten salt electrolyte. The real-time monitoring of actinide concentrations in the molten salt electrolyte is highly desirable for controlling electrochemical operations and assuring materials control and accountancy. However, real-time monitoring is not possible with current methods for sampling and chemical analysis. A new solid-state electrochemical sensor is being developed for real-time monitoring of actinide ion concentrations in a molten salt electrorefiner. The ultimate function of the sensor is to monitor plutonium concentrations during electrorefining operations, but in this work gadolinium was employed as a surrogate material for plutonium. In a parametric study, polycrystalline sodium beta double-prime alumina (Na-ß?-alumina) discs and tubes were subject to vapor-phase exchange with gadolinium ions (Gd3+) using a gadolinium chloride salt (GdCl3) as a precursor to produce gadolinium beta double-prime alumina (Gd-ß?-alumina) samples. Electrochemical impedance spectroscopy and microstructural analysis were performed on the ion-exchanged discs to determine the relationship between ion exchange and Gd3+ ion conductivity. The ion-exchanged tubes were configured as potentiometric sensors in order to monitor real-time Gd3+ ion concentrations in mixtures of gadolinium

  12. SINGLE AND DOUBLE IMPRINTED POLYMER FOR SELECTIVE RECOGNITION OF Cd(II IONS IN AQUEOUS MEDIA

    Directory of Open Access Journals (Sweden)

    Ebru Birlik ÖZKÜTÜK

    2010-12-01

    Full Text Available In this paper, we have reported the synthesis of a new single and double-imprinted polymeric material for the separation of Cd(II ions in aqueous solutions. Chitosan has choosen as the Cd(II metal complexing big polymer for single and double imprinted polymers. In the synthesis of single imprinted polymer, Cd(II-complexed chitosan has crosslinked by epichlorohydrin. In the synthesis of double imprinted polymer, Cd(II-complexed chitosan was reacted with 3-mercaptopropyl-trimethoxysilane. Then, the polymeric beads have crosslinked with tetraethoxysilane (TEOS. The imprinted cadmium ions have removed from the polymeric matrix by 0.1M HNO3 (to prepare Cd(II templates. Optimum pH for rebinding of Cd(II on the single and double-imprinted polymers was 7.0. Equilibrium binding time and sorbent capacity have been found as 120 and 60 min, 342 and 172 mg g-1 for single and double imprinted polymers, respectively. In selectivity studies, it has been found that double imprinted results in increased affinity of the material toward Cd(II ion over other competitor metal ions with the same charge. The prepared single and double-imprinted polymers have repeatedly used and regenerated for thirty times without a significant decrease in polymer binding affinities.

  13. Ion beam synthesis of buried single crystal erbium silicide

    International Nuclear Information System (INIS)

    Golanski, A.; Feenstra, R.; Galloway, M.D.; Park, J.L.; Pennycook, S.J.; Harmon, H.E.; White, C.W.

    1990-01-01

    High doses (10 16 --10 17 /cm 2 ) of 170 keV Er + were implanted into single-crystal left-angle 111 right-angle Si at implantation temperatures between 350 degree C and 520 degree C. Annealing at 800 degree C in vacuum following the implant, the growth and coalescence of ErSi 2 precipitates leads to a buried single crystalline ErSi 2 layer. This has been studied using Rutherford backscattering/channeling, X-ray diffraction, cross-sectional TEM and resistance versus temperature measurements. Samples implanted at 520 degree C using an Er dose of 7 x 10 16 /cm 2 and thermally annealed were subsequently used as seeds for the mesoepitaxial growth of the buried layer during a second implantation and annealing process. Growth occurs meso-epitaxially along both interfaces through beam induced, defect mediated mobility of Er atoms. The crystalline quality of the ErSi 2 layer strongly depends on the temperature during the second implantation. 12 refs., 4 figs

  14. Quantum ion-acoustic oscillations in single-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Khan, S.A. [Kyoto Univ., Katsura (Japan). Graduate School of Engineering; Quaid-i-Azam Univ., Islamabad (Pakistan). National Centre for Physics; Iqbal, Z. [University of Management and Technology, Sialkot (Pakistan); Wazir, Z. [Riphah International Univ., Islamabad (Pakistan). Dept. of Basic Sciences; Rehman, Aman ur [Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad (Pakistan)

    2016-08-01

    Quantum ion-acoustic oscillations in single-walled carbon nanotubes are studied by employing a quantum hydrodynamics model. The dispersion equation is obtained by Fourier transformation, which exhibits the existence of quantum ion-acoustic wave affected by change of density balance due to presence of positive or negative heavy species as stationary ion clusters and wave potential at equilibrium. The numerical results are presented, and the role of quantum degeneracy, nanotube geometry, electron exchange-correlation effects, and concentration and polarity of heavy species on wave dispersion is pointed out for typical systems of interest.

  15. Quantum Ion-Acoustic Oscillations in Single-Walled Carbon Nanotubes

    Science.gov (United States)

    Khan, S. A.; Iqbal, Z.; Wazir, Z.; Aman-ur-Rehman

    2016-05-01

    Quantum ion-acoustic oscillations in single-walled carbon nanotubes are studied by employing a quantum hydrodynamics model. The dispersion equation is obtained by Fourier transformation, which exhibits the existence of quantum ion-acoustic wave affected by change of density balance due to presence of positive or negative heavy species as stationary ion clusters and wave potential at equilibrium. The numerical results are presented, and the role of quantum degeneracy, nanotube geometry, electron exchange-correlation effects, and concentration and polarity of heavy species on wave dispersion is pointed out for typical systems of interest.

  16. Feasibility of Observing and Characterizing Single Ion Strikes in Microelectronic Components.

    Energy Technology Data Exchange (ETDEWEB)

    Dingreville, Remi Philippe Michel [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Hattar, Khalid Mikhiel [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Bufford, Daniel Charles [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)

    2015-11-01

    The transient degradation of semiconductor device performance under irradiation has long been an issue of concern. A single high-energy charged particle can degrade or permanently destroy the microelectronic component, potentially altering the course or function of the systems. Disruption of the the crystalline structure through the introduction of quasi-stable defect structures can change properties from semiconductor to conductor. Typically, the initial defect formation phase is followed by a recovery phase in which defect-defect or defect-dopant interactions modify the characteristics of the damaged structure. In this LDRD Express, in-situ ion irradiation transmission microscopy (TEM) in-situ TEM experiments combined with atomistic simulations have been conducted to determine the feasibility of imaging and characterizing the defect structure resulting from a single cascade in silicon. In-situ TEM experiments have been conducted to demonstrate that a single ion strike can be observed in Si thin films with nanometer resolution in real time using the in-situ ion irradiation transmission electron microscope (I3TEM). Parallel to this experimental effort, ion implantation has been numerically simulated using Molecular Dynamics (MD). This numerical framework provides detailed predictions of the damage and follow the evolution of the damage during the first nanoseconds. The experimental results demonstrate that single ion strike can be observed in prototypical semiconductors.

  17. Single-ion and pair-interaction potentials near simple metal surfaces

    International Nuclear Information System (INIS)

    Barnett, R.N.; Barrera, R.G.; Cleveland, C.L.; Landman, U.

    1983-01-01

    Presented is a model for semi-infinite simple metals which does not require crystalline order or a single species, and thus is applicable to problems of defect energetics near the surface and random-alloy surfaces as well as ideal metal surfaces. The formulation is based on the use of ionic pseudopotentials and linear-response theory. An expression for the total energy is obtained which depends explicitly on ionic species and position. This expression is decomposed into a density-dependent term and single-ion and ionic pair-interaction potential terms. The single-ion potentials oscillate about a constant bulk value, with the magnitude of the oscillation decreasing rapidly away from the surface. The interaction between pairs of ions near the surface is shown to be a noncentral force interaction which differs significantly from the central-force bulk pair potential. The effect of quantum interference in the response of the semi-infinite electron gas to the ions is seen in both the single-ion and the pair-interaction potentials. Results are presented for the simple metals sodium, potassium, and rubidium

  18. Feasibility of Observing and Characterizing Single Ion Strikes in Microelectronic Components

    International Nuclear Information System (INIS)

    Dingreville, Remi Philippe Michel; Hattar, Khalid Mikhiel; Bufford, Daniel Charles

    2015-01-01

    The transient degradation of semiconductor device performance under irradiation has long been an issue of concern. A single high-energy charged particle can degrade or permanently destroy the microelectronic component, potentially altering the course or function of the systems. Disruption of the the crystalline structure through the introduction of quasi-stable defect structures can change properties from semiconductor to conductor. Typically, the initial defect formation phase is followed by a recovery phase in which defect-defect or defect-dopant interactions modify the characteristics of the damaged structure. In this LDRD Express, in-situ ion irradiation transmission microscopy (TEM) in-situ TEM experiments combined with atomistic simulations have been conducted to determine the feasibility of imaging and characterizing the defect structure resulting from a single cascade in silicon. In-situ TEM experiments have been conducted to demonstrate that a single ion strike can be observed in Si thin films with nanometer resolution in real time using the in-situ ion irradiation transmission electron microscope (I 3 TEM). Parallel to this experimental effort, ion implantation has been numerically simulated using Molecular Dynamics (MD). This numerical framework provides detailed predictions of the damage and follow the evolution of the damage during the first nanoseconds. The experimental results demonstrate that single ion strike can be observed in prototypical semiconductors.

  19. State-of-health monitoring of 18650 4S packs with a single-point impedance diagnostic

    Science.gov (United States)

    Love, Corey T.; Virji, Maheboob B. V.; Rocheleau, Richard E.; Swider-Lyons, Karen E.

    2014-11-01

    The state-of-health (SOH) of Li-ion batteries and battery packs must be monitored effectively for abuse to prevent failure and accidents. In a previous publication, we described a single-point impedance diagnostic method for detecting damage in single prismatic lithium polymer rechargeable cells subjected to overcharge abuse. We now determine whether the single-point impedance diagnostic method is applicable to 4S battery packs. At 316 Hz, commercial 18650 LiCoO2 cells are determined to have the least change in impedance response when cycled between 3.0 and 4.2 V, for states-of-charge (SOC) of 0-100%. The impedance response of single cells at 316 Hz changes dramatically during overcharge (SOC = 125%), presumably due to change in their solid electrolyte interface (SEI) layers at the electrodes. When a single cell is purposely subjected to such overcharge abuse and then integrated into a 4S pack with 3 other healthy cells, the impedance response of the 4S pack at 316 Hz also changes, despite variances in the impedance response of each of the 3 healthy cells. The results suggest that this single-point impedance method could serve as a diagnostic in an all-inclusive battery management system to identify overcharge abuse of single cells without individual cell monitoring.

  20. Combined determination of copper ions and β-amyloid peptide by a single ratiometric electrochemical biosensor.

    Science.gov (United States)

    Yu, Yanyan; Wang, Peng; Zhu, Xiaodan; Peng, Qiwen; Zhou, Yi; Yin, Tianxiao; Liang, Yixin; Yin, Xiaoxing

    2017-12-18

    Copper ions (Cu 2+ ) play a critical role in biological processes and are directly involved in β-amyloid peptide (Aβ) aggregation, which is responsible for the occurrence and development of Alzheimer's disease (AD). Therefore, combined determination of Cu 2+ and Aβ in one analytical system is of great significance to understand the exact nature of the AD event. This work presents a novel ratiometric electrochemical biosensor for the dual determination of Cu 2+ and Aβ 1-42 . This unique sensor is based on a 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulphonate) (ABTS) and poly(diallyldimethylammonium chloride) (PDDA)-bi functionalized single-walled carbon nanotubes (ABTS-PDDA/CNTs) composite. The inclusion of ABTS not only enhanced the sensitivity, but it also acted as an inner reference molecule to improve detection accuracy. The specific recognition of Cu 2+ was realized by neurokinin B (NKB) coatings on the ABTS-PDDA/CNTs surface to form a [Cu II (NKB) 2 ] complex with Cu 2+ . The ABTS-PDDA/CNTs-NKB modified electrode also displayed an excellent electrochemical response toward the Aβ 1-42 monomer, when a certain amount of the Aβ 1-42 monomer was added to Cu 2+ -contained PBS buffer, which was due to the release of Cu 2+ from the [Cu II (NKB) 2 ] complex through Aβ binding to Cu 2+ . Meanwhile, our work showed that Cu 2+ bound Aβ 1-42 was concentration-dependent. Consequently, the presented electrochemical approach was capable of quantifying two important biological species associated with AD by one single biosensor, with the detection limits of 0.04 μM for Cu 2+ and 0.5 ng mL -1 for Aβ 1-42 , respectively. Finally, the ratiometric electrode was successfully applied for monitoring Cu 2+ and Aβ 1-42 variations in plasma and hippocampus of normal and AD rats.

  1. Exchange interaction of strongly anisotropic tripodal erbium single-ion magnets with metallic surfaces

    DEFF Research Database (Denmark)

    Dreiser, Jan; Wäckerlin, Christian; Ali, Md. Ehesan

    2014-01-01

    We present a comprehensive study of Er(trensal) single-ion magnets deposited in ultrahigh vacuum onto metallic surfaces. X-ray photoelectron spectroscopy reveals that the molecular structure is preserved after sublimation, and that the molecules are physisorbed on Au(111) while they are chemisorbed....... Furthermore XMCD indicates a weak antiferromagnetic exchange coupling between the single-ion magnets and the ferromagnetic Ni/Cu(100) substrate. For the latter case, spin-Hamiltonian fits to the XMCD M(H) suggest a significant structural distortion of the molecules. Scanning tunneling microscopy reveals...

  2. Xenon gas field ion source from a single-atom tip

    Science.gov (United States)

    Lai, Wei-Chiao; Lin, Chun-Yueh; Chang, Wei-Tse; Li, Po-Chang; Fu, Tsu-Yi; Chang, Chia-Seng; Tsong, T. T.; Hwang, Ing-Shouh

    2017-06-01

    Focused ion beam (FIB) systems have become powerful diagnostic and modification tools for nanoscience and nanotechnology. Gas field ion sources (GFISs) built from atomic-size emitters offer the highest brightness among all ion sources and thus can improve the spatial resolution of FIB systems. Here we show that the Ir/W(111) single-atom tip (SAT) can emit high-brightness Xe+ ion beams with a high current stability. The ion emission current versus extraction voltage was analyzed from 150 K up to 309 K. The optimal emitter temperature for maximum Xe+ ion emission was ˜150 K and the reduced brightness at the Xe gas pressure of 1 × 10-4 torr is two to three orders of magnitude higher than that of a Ga liquid metal ion source, and four to five orders of magnitude higher than that of a Xe inductively coupled plasma ion source. Most surprisingly, the SAT emitter remained stable even when operated at 309 K. Even though the ion current decreased with increasing temperature, the current at room temperature (RT) could still reach over 1 pA when the gas pressure was higher than 1 × 10-3 torr, indicating the feasibility of RT-Xe-GFIS for application to FIB systems. The operation temperature of Xe-SAT-GFIS is considerably higher than the cryogenic temperature required for the helium ion microscope (HIM), which offers great technical advantages because only simple or no cooling schemes can be adopted. Thus, Xe-GFIS-FIB would be easy to implement and may become a powerful tool for nanoscale milling and secondary ion mass spectroscopy.

  3. TRIPLICATE SODIUM IODIDE GAMMA RAY MONITORS FOR THE SMALL COLUMN ION EXCHANGE PROGRAM

    Energy Technology Data Exchange (ETDEWEB)

    Couture, A.

    2011-09-20

    This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ({sup 137}Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241({sup 241}Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the {sup 137}Cs full-energy {gamma}-ray peak and the {sup 241}Am alpha peak. The count rate in the gamma peak region will be proportional to the {sup 137}Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical {sup 137}Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing {sup 137}Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF

  4. Triplicate Sodium Iodide Gamma Ray Monitors For The Small Column Ion Exchange Program

    International Nuclear Information System (INIS)

    Couture, A.

    2011-01-01

    This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ( 137 Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241( 241 Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the 137 Cs full-energy γ-ray peak and the 241 Am alpha peak. The count rate in the gamma peak region will be proportional to the 137 Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical 137 Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing 137 Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF) to be incorporated into grout.

  5. The beam monitor system for heavy ion shallow in tumor therapy

    International Nuclear Information System (INIS)

    Tang Bin; Hu Zhengguo; Xu Zhiguo; Mao Ruishi; Zhang Xueheng; Tu Xiaolin; Guo Zhongyan; Sun Zhiyu; Wang Meng; Xiao Guoqing; Xu Hushan

    2008-01-01

    The program of heavy ion shallow tumor therapy has been started. The beam monitor system for the therapy is described in this paper. It is composed of plastic scintillator, which used to monitor the stability of beam intensity and control the irradiation dose, and PPAC which is to measure the beam homogeneity in the irradiation area. This system has shown good performance in the clinic experiments of the shallow tumor therapy. (authors)

  6. Single-photon emission correlated to double-electron capture by bare ions: background processes

    Science.gov (United States)

    Elkafrawy, T.; Warczak, A.; Simon, A.; Tanis, J. A.

    2013-09-01

    Radiative single- and double-electron capture are one-step processes where a single target electron or two target electrons, respectively, are captured to a bound state of a highly charged projectile with the simultaneous emission of a single photon. In ion-atom collisions, several background processes are likely to contribute to these processes and may interfere with the measured x-rays due to radiative single and double capture. In this study, possible contributions from radiative electron capture to the continuum, secondary electron bremsstrahlung, the two-step process of independent double radiative electron capture, as well as radiative- combined with nonradiative-electron capture are taken into account based on our analysis of the data for 2.21 MeV u-1 F9+ ions colliding with a thin carbon foil.

  7. Structural and optical properties of Cd2+ ion on the growth of sulphamic acid single crystals

    Science.gov (United States)

    Rajyalakshmi, S.; Rao, Valluru Srinivasa; Reddy, P. V. S. S. S. N.; Krishna, V. Y. Rama; Samatha, K.; Rao, K. Ramachandra

    2016-05-01

    Transparent single crystals of Cadmium doped Sulphamic acid (SA) was grown by Conventional slow evaporation solution technique (SEST) which had the size of 13 × 8 × 7 mm3. The grown single crystals have been characterized using single crystal X-ray diffraction UV-visible Spectral studies and Second harmonic generation (SHG) efficiency and the results were discussed. The lattice parameters of the grown Cd2+ ion doped SA crystal are confirmed by single crystal X-ray diffraction and belong to orthorhombic system. Optical transmittance of the crystal was recorded using UV-vis NIR spectrophotometer with its lower cut off wavelength around 259nm. SHG measurements indicate that the SHG efficiency of the grown Cd2+ ion doped SA crystal at a fundamental wavelength of 1064 nm is approximately equal to KDP.

  8. Development of ion-exchange collectors for monitoring atmospheric deposition of inorganic pollutants in Alaska parklands

    Science.gov (United States)

    Brumbaugh, William G.; Arms, Jesse W.; Linder, Greg L.; Melton, Vanessa D.

    2016-09-19

    Between 2010 and 2014, the U.S. Geological Survey completed a series of laboratory and field experiments designed to develop methodology to support the National Park Service’s long-term atmospheric pollutant monitoring efforts in parklands of Arctic Alaska. The goals of this research were to develop passive sampling methods that could be used for long-term monitoring of inorganic pollutants in remote areas of arctic parklands and characterize relations between wet and dry deposition of atmospheric pollutants to that of concentrations accumulated by mosses, specifically the stair-step, splendid feather moss, Hylocomium splendens. Mosses and lichens have been used by National Park Service managers as atmospheric pollutant biomonitors since about 1990; however, additional research is needed to better characterize the dynamics of moss bioaccumulation for various classes of atmospheric pollutants. To meet these research goals, the U.S. Geological Survey investigated the use of passive ionexchange collectors (IECs) that were adapted from the design of Fenn and others (2004). Using a modified IEC configuration, mulitple experiments were completed that included the following: (a) preliminary laboratory and development testing of IECs, (b) pilot-scale validation field studies during 2012 with IECs at sites with instrumental monitoring stations, and (c) deployment of IECs in 2014 at sites in Alaska having known or suspected regional sources of atmospheric pollutants where samples of Hylocomium splendens moss also could be collected for comparison. The targeted substances primarily included ammonium, nitrate, and sulfate ions, and certain toxicologically important trace metals, including cadmium, cobalt, copper, nickel, lead, and zinc.Deposition of atmospheric pollutants is comparatively low throughout most of Alaska; consequently, modifications of the original IEC design were needed. The most notable modification was conversion from a single-stage mixed-bed column to a two

  9. Study of single and binary ion plasma expansion into laboratory-generated plasma wakes

    International Nuclear Information System (INIS)

    Wright, K.H. Jr.

    1988-02-01

    Plasma expansion into the wake of a large rectangular plate immersed in a collisionless, supersonic plasma was investigated in laboratory experiments. The experimental conditions address both single ion and binary ion plasma flows for the case of a body whose size is large in comparison with the Debye length, when the potential difference between the body and the plasma is relatively small. A new plasma source was developed to generate equi-velocity, binary ion plasma flows, which allows access to new parameter space that have previously been unavailable for laboratory studies. Specifically, the new parameters are the ionic mass ratio and the ionic component density ratio. In a series of experiments, a krypton-neon plasma is employed where the ambient density ratio of neon to krypton is varied more than an order of magnitude. The expansion in both the single ion and binary ion plasma cases is limited to early times, i.e., a few ion plasma periods, by the combination of plasma density, plasma drift speed, and vacuum chamber size, which prevented detailed comparison with self-similar theory

  10. Ion beam induced single phase nanocrystalline TiO{sub 2} formation

    Energy Technology Data Exchange (ETDEWEB)

    Rukade, Deepti A. [Department of Physics, University of Mumbai, Mumbai 400098 (India); Tribedi, L.C. [Tata Institute of Fundamental Research, Homi Bhabha Road, Colaba, Mumbai 400005 (India); Bhattacharyya, Varsha, E-mail: varsha.b1.physics@gmail.com [Department of Physics, University of Mumbai, Mumbai 400098 (India)

    2014-06-15

    Single phase TiO{sub 2} nanostructures are fabricated by oxygen ion implantation (60 keV) at fluence ranging from 1×10{sup 16} ions/cm{sup 2} to 1×10{sup 17} ions/cm{sup 2} in titanium thin films deposited on fused silica substrate and subsequent thermal annealing in argon atmosphere. GAXRD and Raman spectroscopy study reveals formation of single rutile phases of TiO{sub 2}. Particle size is found to vary from 29 nm to 35 nm, establishing nanostructure formation. Nanostructure formation is also confirmed by the quantum confinement effect manifested by the blueshift of the UV–vis absorption spectra. Photoluminescence spectra show peaks corresponding to TiO{sub 2} rutile phase and reveal the presence of oxygen defects due to implantation. The controlled synthesis of single phase nanostructure is attributed to ion induced defects and post-implantation annealing. It is observed that the size of the nanostructures formed is strongly dependent on the ion fluence.

  11. Ion mass dependence for low energy channeling in single-wall nanotubes

    International Nuclear Information System (INIS)

    An Monte Carlo (MC) simulation program has been used to study ion mass dependence for the low energy channeling of natural- and pseudo-Ar ions in single-wall nanotubes. The MC simulations show that the channeling critical angle Ψ C obeys the (E) -1/2 and the (M 1 ) -1/2 rules, where E is the incident energy and M 1 is the ion mass. The reason for this may be that the motion of the channeled (or de-channeled) ions should be correlated with both the incident energy E and the incident momentum (2M 1 E) 1/2 , in order to obey the conservation of energy and momentum

  12. Heavy doping of CdTe single crystals by Cr ion implantation

    Science.gov (United States)

    Popovych, Volodymyr D.; Böttger, Roman; Heller, Rene; Zhou, Shengqiang; Bester, Mariusz; Cieniek, Bogumil; Mroczka, Robert; Lopucki, Rafal; Sagan, Piotr; Kuzma, Marian

    2018-03-01

    Implantation of bulk CdTe single crystals with high fluences of 500 keV Cr+ ions was performed to achieve Cr concentration above the equilibrium solubility limit of this element in CdTe lattice. The structure and composition of the implanted samples were studied using secondary ion mass spectrometry (SIMS), scanning electron microscopy (SEM), energy dispersive X-ray (EDX) analysis, X-ray diffraction (XRD) and Rutherford backscattering spectrometry (RBS) to characterize the incorporation of chromium into the host lattice and to investigate irradiation-induced damage build-up. It was found that out-diffusion of Cr atoms and sputtering of the targets alter the depth distribution and limit concentration of the projectile ions in the as-implanted samples. Appearance of crystallographically oriented, metallic α-Cr nanoparticles inside CdTe matrix was found after implantation, as well as a strong disorder at the depth far beyond the projected range of the implanted ions.

  13. Magnetic anisotropy of a Co-II single ion magnet with distorted trigonal prismatic coordination

    DEFF Research Database (Denmark)

    Peng, Yan; Bodenstein, Tilmann; Fink, Karin

    2016-01-01

    (methanylylidene)) bis(2-methoxyphenol) coordinates to Co(II) does indeed lead to enhanced single-ion behaviour as has previously been predicted. Synthesis of the compound, structural information, and static as well as dynamic magnetic data are presented along with an analysis using quantum chemical ab initio......The single ion magnetic properties of Co(II) are affected by the details of the coordination geometry of the ion. Here we show that a geometry close to trigonal prismatic which arises when the ligand 6,6'-((1Z)-((piperazine-1,4-diylbis(propane-3,1-diyl)) bis(azanylylidene)) bis...... calculations. Though the complex shows a slight deviation from an ideal trigonal prismatic coordination, the zero-field splitting as well as the g-tensor are strongly axial with D = -41 cm(-1) and E

  14. Development of noise-suppressed detector for single ion hit system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Takuro; Hamano, Tsuyoshi; Suda, Tamotsu; Hirao, Toshio; Kamiya, Tomihiro [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    A noise-suppressed detector for single ion detection has been developed, and combined with the heavy ion microbeam apparatus. This detector consists of a pair of micro channel plates (MCP`s) and a very thin carbon foil. The detection signal is formed by the coincidence of the signals from these MCP`s, so that this detector and the coincidence measurement unit can reduce miscounting in the circuit. The detection efficiency for 15 MeV heavy ions was evaluated to be comparable to that of a silicon surface-barrier detector (SSD) and the miscounting rate was 4 orders lower than the noise rate of a single MCP. The rise time of the detection signal was also estimated. (author)

  15. Surface structure modification of single crystal graphite after slow, highly charged ion irradiation

    Science.gov (United States)

    Alzaher, I.; Akcöltekin, S.; Ban-d'Etat, B.; Manil, B.; Dey, K. R.; Been, T.; Boduch, P.; Rothard, H.; Schleberger, M.; Lebius, H.

    2018-04-01

    Single crystal graphite was irradiated by slow, highly charged ions. The modification of the surface structure was studied by means of Low-Energy Electron Diffraction. The observed damage cross section increases with the potential energy, i.e. the charge state of the incident ion, at a constant kinetic energy. The potential energy is more efficient for the damage production than the kinetic energy by more than a factor of twenty. Comparison with earlier results hints to a strong link between early electron creation and later target atom rearrangement. With increasing ion fluence, the initially large-scale single crystal is first transformed into μ m-sized crystals, before complete amorphisation takes place.

  16. Production of multi-, oligo- and single-pore membranes using a continuous ion beam

    Energy Technology Data Exchange (ETDEWEB)

    Apel, P.Yu., E-mail: apel@nrmail.jinr.ru [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna (Russian Federation); Dubna International University, Universitetskaya Str. 19, 141980 Dubna (Russian Federation); Ivanov, O.M.; Lizunov, N.E.; Mamonova, T.I.; Nechaev, A.N. [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna (Russian Federation); Olejniczak, K. [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna (Russian Federation); Faculty of Chemistry, Nicolaus Copernicus University, Gagarina Str. 7, 87-100 Torun (Poland); Vacik, J. [Nuclear Physics Institute, ASCR, v.v.i., 25068 Řež (Czech Republic); Dmitriev, S.N. [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Joliot-Curie Str. 6, 141980 Dubna (Russian Federation)

    2015-12-15

    Ion track membranes (ITM) have attracted significant interest over the past two decades due to their numerous applications in physical, biological, chemical, biochemical and medical experimental works. A particular feature of ITM technology is the possibility to fabricate samples with a predetermined number of pores, including single-pore membranes. The present report describes a procedure that allowed for the production of multi-, oligo- and single-pore membranes using a continuous ion beam from an IC-100 cyclotron. The beam was scanned over a set of small diaphragms, from 17 to ∼1000 μm in diameter. Ions passed through the apertures and impinged two sandwiched polymer foils, with the total thickness close to the ion range in the polymer. The foils were pulled across the ion beam at a constant speed. The ratio between the transport speed and the scanning frequency determined the distance between irradiation spots. The beam intensity and the aperture diameters were adjusted such that either several, one or no ions passed through the diaphragms during one half-period of scanning. After irradiation, the lower foil was separated from the upper foil and was etched to obtain pores 6–8 μm in diameter. The pores were found using a color chemical reaction between two reagents placed on opposite sides of the foil. The located pores were further confirmed using SEM and optical microscopy. The numbers of tracks in the irradiation spots were consistent with the Poisson statistics. Samples with single or few tracks obtained in this way were employed to study fine phenomena in ion track nanopores.

  17. Potential of electric quadrupole transitions in radium isotopes for single-ion optical frequency standards

    NARCIS (Netherlands)

    Versolato, O. O.; Wansbeek, L. W.; Jungmann, K.; Timmermans, R. G. E.; Willmann, L.; Wilschut, H. W.

    2011-01-01

    We explore the potential of the electric quadrupole transitions 7s (2)S(1/2)-(6)d (2)D(3/2), 6d (2)D(5/2) in radium isotopes as single-ion optical frequency standards. The frequency shifts of the clock transitions due to external fields and the corresponding uncertainties are calculated. Several

  18. Towards a Precise Measurement of Atomic Parity Violation in a Single Ra+ Ion

    NARCIS (Netherlands)

    Jungmann, K.; Giri, G. S.; Versolato, O. O.; Steadman, SG; Stephans, GSF; Taylor, FE

    2012-01-01

    In the singly charged Ra+ ion the contributions of the weak interactions to the atomic level energies are some 50 times larger than in the Cs atom. We report the results of laser spectroscopy experiments on Ra-209-214(+) isotopes in preparation of a precision atomic parity violation experiment.

  19. Dimer self-organization of impurity ytterbium ions in synthetic forsterite single crystals

    Science.gov (United States)

    Tarasov, V. F.; Sukhanov, A. A.; Dudnikova, V. B.; Zharikov, E. V.; Lis, D. A.; Subbotin, K. A.

    2017-07-01

    Paramagnetic centers formed by impurity Yb3+ ions in synthetic forsterite (Mg2SiO4) grown by the Czochralski technique are studied by X-band CW and pulsed EPR spectroscopy. These centers are single ions substituting magnesium in two different crystallographic positions denoted M1 and M2, and dimer associates formed by two Yb3+ ions in nearby positions M1. It is established that there is a pronounced mechanism favoring self-organization of ytterbium ions in dimer associates during the crystal growth, and the mechanism of the spin-spin coupling between ytterbium ions in the associate has predominantly a dipole-dipole character, which makes it possible to control the energy of the spin-spin interaction by changing the orientation of the external magnetic field. The structural computer simulation of cluster ytterbium centers in forsterite crystals is carried out by the method of interatomic potentials using the GULP 4.0.1 code (General Utility Lattice Program). It is established that the formation of dimer associates in the form of a chain parallel to the crystallographic axis consisting of two ytterbium ions with a magnesium vacancy between them is the most energetically favorable for ytterbium ions substituting magnesium in the position M1.

  20. Transport of ions and biomolecules through asymmetric single nanopores fabricated by heavy ion irradiation and chemical etching

    International Nuclear Information System (INIS)

    Neumann, R.; Siwy, Z.; Schiedt, B.; Toimil Molares, M.E.

    2005-01-01

    In the framework of the CRP 'Radiation Synthesis of Stimuli-responsive Membranes, Hydrogels and Adsorbents for Separation Purposes', GSI has worked on the production of polymeric single conical nanopores and the study of the ionic transport through these pores. To produce single-pore membranes, polyethylene teraphthalate (PET) and polyimide (PI) foils were first irradiated with GeV single heavy ions. By subsequent one-side etching, asymmetric nanopores were created. The diameter of the conical pores in PET varied between 4-20 nm at the small opening and several hundred nm at the large opening. In the case of PI, due to the higher bulk etching rate, the large aperture reached a few μm. The current-voltage (I-V) characteristics were measured at symmetric electrolyte conditions of KCl at various concentrations and pH values. It was found that conical nanopores with charged surfaces are cation selective, and show preferential cation flow (i.e. rectification) from the narrow entrance to the wide opening of the cone. Concentration and pH influence the rectification properties for both polymers was studied. The experimental results are in agreement with existing models. The transient transport properties of single PET and PI pores were also investigated. The ion current through PET nanopores fluctuates considerably, the fluctuation depending on the voltage, whereas PI nanopores display a stable current signal for KCl concentrations between 0.1 and 3 M, and pH values between 2 and 8. This different behavior has been attributed to the chemical structure of the two polymers influencing surface characteristics of the resulting nanopores. Finally, the application of polyimide conical nanopores as single-molecule-DNA sensors is being investigated. First results demonstrate their ability to detect individual plasmid DNA molecules. The nanopore sensor is also able to discriminate between DNA fragments of different lengths. (author)

  1. Deep level defects in 4H-SiC introduced by ion implantation: the role of single ion regime.

    Science.gov (United States)

    Pastuović, Željko; Siegele, Rainer; Capan, Ivana; Brodar, Tomislav; Sato, Shin-Ichiro; Ohshima, Takeshi

    2017-11-29

    We characterized intrinsic deep level defects created in ion collision cascades which were produced by patterned implantation of single accelerated 2.0 MeV He and 600 keV H ions into n-type 4H-SiC epitaxial layers using a fast-scanning reduced-rate ion microbeam. The initial deep level transient spectroscopy measurement performed on as-grown material in the temperature range 150-700 K revealed the presence of only two electron traps, Z 1/2 (0.64 eV) and EH 6/7 (1.84 eV) assigned to the two different charge state transitions of the isolated carbon vacancy, V C (=/0) and (0/+). C-V measurements of as-implanted samples revealed the increasing free carrier removal with larger ion fluence values, in particular at depth corresponding to a vicinity of the end of an ion range. The first DLTS measurement of as-implanted samples revealed formation of additional deep level defects labelled as ET1 (0.35 eV), ET2 (0.65 eV) and EH3 (1.06 eV) which were clearly distinguished from the presence of isolated carbon vacancies (Z 1/2 and EH 6/7 defects) in increased concentrations after implantations either by He or H ions. Repeated C-V measurements showed that a partial net free-carrier recovery occurred in as-implanted samples upon the low-temperature annealing following the first DLTS measurement. The second DLTS measurement revealed the almost complete removal of ET2 defect and the partial removal of EH3 defect, while the concentrations of Z 1/2 and EH 6/7 defects increased, due to the low temperature annealing up to 700 K accomplished during the first temperature scan. We concluded that the ET2 and EH3 defects: (i) act as majority carrier removal traps, (ii) exhibit a low thermal stability and (iii) can be related to the simple point-like defects introduced by light ion implantation, namely interstitials and/or complex of interstitials and vacancies in both carbon and silicon sub-lattices.

  2. Monitoring of trace chloride ions at different stages of the gas production process

    Directory of Open Access Journals (Sweden)

    A.Y. El Naggar

    2015-01-01

    Full Text Available Fifty gas and liquid samples at different stages of Obaiyed gas plant in Egypt were selected and subjected for determining chloride ion and hydrocarbon compositions. The trace levels of chloride in the water extracted from natural gas, condensate, Benfield and glycol samples were achieved using ion chromatograph (IC, electrical, conductivity and potentiometric methods, respectively. The hydrocarbon compositions were analyzed and evaluated using capillary gas chromatography. The chloride ions in natural gas and condensate are a function of water content and their concentration mainly depends on the separation efficiency. Variability in natural gas and condensate compositions seasonally is not an uncommon occurrence. Our aim is monitoring of chloride ion to select and optimize the conditions of sweetening and dehydration regenerators in order to follow and prevent their gradient in gas plant.

  3. Effect of H + ion implantation on structural, morphological, optical and dielectric properties of L-arginine monohydrochloride monohydrate single crystals

    Science.gov (United States)

    Sangeetha, K.; Babu, R. Ramesh; Kumar, P.; Bhagvannarayana, G.; Ramamurthi, K.

    2011-06-01

    L-arginine monohydrochloride monohydrate (LAHCl) single crystals have been implanted with 100 keV H + ions at different ion fluence ranging from 10 12 to 10 15 ions/cm 2. Implanted LAHCl single crystals have been investigated for property changes. Crystal surface and crystalline perfection of the pristine and implanted crystals were analyzed by atomic force microscope and high-resolution X-ray diffraction studies, respectively. Optical absorption bands induced by colour centers, refractive index and birefringence, mechanical stability and dielectric constant of implanted crystals were studied at different ion fluence and compared with that of pristine LAHCl single crystal.

  4. Modification of mechanical properties of single crystal aluminum oxide by ion beam induced structural changes

    International Nuclear Information System (INIS)

    Ensinger, W.; Nowak, R.; Horino, Y.; Baba, K.

    1993-01-01

    The mechanical behaviour of ceramics is essentially determined by their surface qualities. As a surface modification technique, ion implantation provides the possibility to modify the mechanical properties of ceramics. Highly energetic ions are implanted into the near-surface region of a material and modify its composition and structure. Ions of aluminum, oxygen, nickel and tantalum were implanted into single-crystal α-aluminum oxide. Three-point bending tests showed that an increase in flexural strength of up to 30% could be obtained after implantation of aluminum and oxygen. Nickel and tantalum ion implantation increased the fracture toughness. Indentation tests with Knoop and Vickers diamonds and comparison of the lengths of the developed radial cracks showed that ion implantation leads to a reaction in cracking. The observed effects are assigned to radiation induced structural changes of the ceramic. Ion bombardment leads to radiation damage and formation of compressive stress. In case of tantalum implantation, the implanted near-surface zone becomes amorphous. These effects make the ceramic more resistant to fracture. (orig.)

  5. Engineering of electronic properties of single layer graphene by swift heavy ion irradiation

    Science.gov (United States)

    Kumar, Sunil; Kumar, Ashish; Tripathi, Ambuj; Tyagi, Chetna; Avasthi, D. K.

    2018-04-01

    In this work, swift heavy ion irradiation induced effects on the electrical properties of single layer graphene are reported. The modulation in minimum conductivity point in graphene with in-situ electrical measurement during ion irradiation was studied. It is found that the resistance of graphene layer decreases at lower fluences up to 3 × 1011 ions/cm2, which is accompanied by the five-fold increase in electron and hole mobilities. The ion irradiation induced increase in electron and hole mobilities at lower fluence up to 1 × 1011 ions/cm2 is verified by separate Hall measurements on another irradiated graphene sample at the selected fluence. In contrast to the adverse effects of irradiation on the electrical properties of materials, we have found improvement in electrical mobility after irradiation. The increment in mobility is explained by considering the defect annealing in graphene after irradiation at a lower fluence regime. The modification in carrier density after irradiation is also observed. Based on findings of the present work, we suggest ion beam irradiation as a useful tool for tuning of the electrical properties of graphene.

  6. Single Qubit Manipulation in a Microfabricated Surface Electrode Ion Trap (Open Access, Publisher’s Version)

    Science.gov (United States)

    2013-09-13

    electrode ion trap with field compensation using a modulated Raman effect D T C Allcock, J A Sherman, D N Stacey et al. Spatially uniform single-qubit gate...in thermal states of motion G Kirchmair, J Benhelm, F Zähringer et al. Normal modes of trapped ions in the presence of anharmonic trap potentials J P...Qloaded = 280) [35]. New Journal of Physics 15 (2013) 093018 (http://www.njp.org/) 5 2.1 GHz Zeeman = 1.4 MHz/G 36 9. 5 nm HF = 12.6 GHz 171Yb+ 2P 1

  7. Changes in ion channel geometry resolved to sub-angstroem precision via single molecule mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, Joseph W F; Kasianowicz, John J; Reiner, Joseph E [Semiconductor Electronics Division, Electronics and Electrical Engineering Laboratory, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States)

    2010-11-17

    The ion channel formed by Staphylococcus aureus alpha-hemolysin switches between multiple open conducting states. We describe a method for precisely estimating the changes in the ion channel geometry that correspond to these different states. Experimentally, we observed that the permeability of a single channel to differently sized poly(ethylene glycol) molecules depends on the magnitude of the open state conductance. A simple theory is proposed for determining changes in channel length of 4.2% and in cross-sectional area of - 0.4%.

  8. Single electron attachment and stripping cross sections for relativistic heavy ions

    International Nuclear Information System (INIS)

    Crawford, H.J.

    1979-06-01

    The results of a Bevalac experiment to measure the single electron attachment and stripping cross sections for relativistic (0.5 1 , and fully stripped, N 0 , ion beams emerging from the targets. Separate counters measured the number of ions in each charge state. The ratios N 1 /N 0 for different target thicknesses were fit to a simple growth curve to yield electron attachment and stripping cross sections. The data are compared to relativistic extrapolations of available theories. Clear evidence for two separate attachment processes, radiative and non-radiative, is found. Data are compared to a recently improved formulation for the stripping cross sections

  9. Single electron attachment and stripping cross sections for relativistic heavy ions

    International Nuclear Information System (INIS)

    Crawford, H.J.

    1979-01-01

    The results of a Bevalac experiment to measure the single electron attachment and stripping cross sections for relativistic (0.5 1 , and fully stripped, N 0 , ion beams emerging from the targets. Separate counters measured the number of ions in each charge state. The ratios N 1 /N 0 for different target thicknesses were fit to a simple growth curve to yield electron attachment and stripping cross sections. The data are compared to relativistic extrapolations of available theories. Clear evidence of two separate attachment processes, radiative and non-radiative, is found. Data are compared to a recently improved formulation for the stripping cross sections

  10. The tensile effect on crack formation in single crystal silicon irradiated by intense pulsed ion beam

    Science.gov (United States)

    Liang, Guoying; Shen, Jie; Zhang, Jie; Zhong, Haowen; Cui, Xiaojun; Yan, Sha; Zhang, Xiaofu; Yu, Xiao; Le, Xiaoyun

    2017-10-01

    Improving antifatigue performance of silicon substrate is very important for the development of semiconductor industry. The cracking behavior of silicon under intense pulsed ion beam irradiation was studied by numerical simulation in order to understand the mechanism of induced surface peeling observed by experimental means. Using molecular dynamics simulation based on Stillinger Weber potential, tensile effect on crack growth and propagation in single crystal silicon was investigated. Simulation results reveal that stress-strain curves of single crystal silicon at a constant strain rate can be divided into three stages, which are not similar to metal stress-strain curves; different tensile load velocities induce difference of single silicon crack formation speed; the layered stress results in crack formation in single crystal silicon. It is concluded that the crack growth and propagation is more sensitive to strain rate, tensile load velocity, stress distribution in single crystal silicon.

  11. A SUBSTRATE AND A METHOD FOR DETERMINING AND/OR MONITORING ELECTROPHYSIOLOGICAL PROPERTIES OF ION CHANNELS

    DEFF Research Database (Denmark)

    2001-01-01

    The present invention relates to a substrate and a method for obtaining an electrophysiological measuring configuration in which a cell forms a high resistive seal (giga-seal) around a measuring electrode making it suitable for determining and monitoring a current flow through the cell membrane...... and reference electrodes formed by wafer processing technology. The electrodes are adapted to conduct a current between them by delivery of ions by one electrode and receipt of ions by the other electrode and are typically silver/silver halide electrodes. This allows for effective and fast measuring of cells...

  12. Development of the work function monitoring method for a converter of a negative ion source

    International Nuclear Information System (INIS)

    Yamaoka, Hitoshi; Sasao, Mamiko; Wada, Motoi; Ramos, H.J.

    1988-07-01

    A method to monitor the change in the work function of the converter surface in a self-extraction negative ion source is developed. The photoelectron emission from the Cs-Mo surface in a plasma is detected by irradiating surface with laser lights. Negative ions produced at the surface shows a strong correlation with the photoelectron current from the surface in hydrogen and helium discharges. The photoelectron current induced by the Ar + laser is used to detect the change in the cesium coverage, or the work function, while that by the dye laser is found to be suitable to confirm the region of the work function minimum. (author)

  13. Potentiometric Sensor for Real-Time Monitoring of Multivalent Ion Concentrations in Molten Salt

    International Nuclear Information System (INIS)

    Zink, Peter A.; Jue, Jan-Fong; Serrano, Brenda E.; Fredrickson, Guy L.; Cowan, Ben F.; Herrmann, Steven D.; Li, Shelly X.

    2010-01-01

    Electrorefining of spent metallic nuclear fuel in high temperature molten salt systems is a core technology in pyroprocessing, which in turn plays a critical role in the development of advanced fuel cycle technologies. In electrorefining, spent nuclear fuel is treated electrochemically in order to effect separations between uranium, noble metals, and active metals, which include the transuranics. The accumulation of active metals in a lithium chloride-potassium chloride (LiCl-KCl) eutectic molten salt electrolyte occurs at the expense of the UCl3-oxidant concentration in the electrolyte, which must be periodically replenished. Our interests lie with the accumulation of active metals in the molten salt electrolyte. The real-time monitoring of actinide concentrations in the molten salt electrolyte is highly desirable for controlling electrochemical operations and assuring materials control and accountancy. However, real-time monitoring is not possible with current methods for sampling and chemical analysis. A new solid-state electrochemical sensor is being developed for real-time monitoring of actinide ion concentrations in a molten salt electrorefiner. The ultimate function of the sensor is to monitor plutonium concentrations during electrorefining operations, but in this work gadolinium was employed as a surrogate material for plutonium. In a parametric study, polycrystalline sodium beta double-prime alumina (Na-β(double p rime)-alumina) discs and tubes were subject to vapor-phase exchange with gadolinium ions (Gd3+) using a gadolinium chloride salt (GdCl3) as a precursor to produce gadolinium beta double-prime alumina (Gd-β(double p rime)-alumina) samples. Electrochemical impedance spectroscopy and microstructural analysis were performed on the ion-exchanged discs to determine the relationship between ion exchange and Gd3+ ion conductivity. The ion-exchanged tubes were configured as potentiometric sensors in order to monitor real-time Gd3+ ion concentrations in

  14. Damage evolution in Xe-ion irradiated rutile (TiO2) single crystals

    International Nuclear Information System (INIS)

    Li, F.; Sickafus, K.E.; Evans, C.R.; Nastasi, M.

    1999-01-01

    Rutile (TiO 2 ) single crystals with (110) orientation were irradiated with 360 keV Xe 2+ ions at 300 K to fluences ranging from 2 x 10 19 to 1 x 10 20 Xe/m 2 . Irradiated samples were analyzed using: (1) Rutherford backscattering spectroscopy combined with ion channeling analysis (RBS/C); and (2) cross-sectional transmission electron microscopy (XTEM). Upon irradiation to a fluence of 2 x 10 19 Xe/m 2 , the sample thickness penetrated by the implanted ions was observed to consist of three distinct layers: (1) a defect-free layer at the surface (thickness about 12 nm) exhibiting good crystallinity; (2) a second layer with a low density of relatively large-sized defects; and (3) a third layer consisting of a high concentration of small defects. After the fluence was increased to 7 x 10 19 Xe/m 2 , a buried amorphous layer was visible by XTEM. The thickness of the amorphous layer was found to increase with increasing Xe ion fluence. The location of this buried amorphous layer was found to coincide with the measured peak in the Xe concentration (measured by RBS/C), rather than with the theoretical maximum in the displacement damage profile. This observation suggests the implanted Xe ions may serve as nucleation sites for the amorphization transformation. The total thickness of the damaged microstructure due to ion irradiation was always found to be much greater than the projected range of the Xe ions. This is likely due to point defect migration under the high stresses induced by ion implantation

  15. A new tritium monitor design based on plasma source ion implantation technique

    Science.gov (United States)

    Nassar, Rafat Mohammad

    Tritium is an important isotope of hydrogen. The availability of tritium in our environment is manifest through both natural and artificial sources. Consequently, the requirement for tritium handling and usage will continue to increase in the future. An important future contributor is nuclear fusion power plants and facilities. Essential safety regulations and procedures require effective monitoring and measurements of tritium concentrations in workplaces. The unique characteristics of tritium impose an important role on the criteria for its detection and measurement. As tritium decays by the emission of soft beta particles, maximum 18 keV, it cannot be readily detected by commonly used detectors. Specially built monitors are required. Additional complications occur due to the presence of other radioactive isotopes or ambient radiation fields and because of the high diffusivity of tritium. When it is in oxidized form it is 25000 times more hazardous biologically than when in elemental form. Therefore, contamination of the monitor is expected and compound specific monitors are important. A summary is given of the various well known methods of detecting tritium-in-air. This covers the direct as well as the indirect measuring techniques, although each has been continually improved and further developed, nevertheless, each has its own limitations. Ionization chambers cannot discriminate against airborne P emitters. Proportional counters have a narrow operating range, 3-4 decades, and have poor performance in relatively high humid environments and require a dry counting gas. Liquid scintillation counters are sensitive, but inspection of the sample is slow and they produce chemical liquid waste. A new way to improve the sensitivity of detecting tritium with plastic scintillators has been developed. The technique is based on a non-line-of-sight implantation of tritium ions into a 20 mum plastic scintillator using a plasma source ion implantation (PSII) technique, This

  16. A new PPP algorithm for deformation monitoring with single ...

    Indian Academy of Sciences (India)

    tem) deformation monitoring has been widely rec- ognized (Jin et al. 2007; Banerjee et al. 2008; Shi et al. 2010) in recent years. To date, there are two approaches that can be used in deformation mon- itoring with GPS: network solution (Bock et al. 1986; Blewwit 1989; Wang et al. 2002) and PPP. (Zumberge et al. 1997; Ge ...

  17. A new PPP algorithm for deformation monitoring with single ...

    Indian Academy of Sciences (India)

    ... a combination of kinematic PPP and sliding window based static PPP algorithm is adopted. To confirm the availability of the algorithm for deformation monitoring with SF receiver, a seismic experiment is carried out on an earthquake simulation platform. Comparable positioning precision with 1.5 cm for horizontal and 2.2 ...

  18. A new PPP algorithm for deformation monitoring with single ...

    Indian Academy of Sciences (India)

    monitoring with SF receiver, a seismic experiment is carried out on an earthquake simulation platform. Comparable positioning precision with 1.5 .... validated with SF data of a simulated earthquake experiment carried out by an earthquake .... and Niell mapping function using predicted mete- orological parameters, and the ...

  19. Single-column ion chromatography with determination of hydrazoic acid produced in spent nuclear fuel reprocessing

    International Nuclear Information System (INIS)

    Ma Guilan; Tan Shuping

    2006-01-01

    The reaction of hydrazine and its derivative with ammonium metavanadate may produce hydrazoic acid (HN 3 ). A single-column ion chromatography is used for the determination of HN 3 after neutralizing the rest acid in the sample with sodium hydroxide. Chromatography separation of HN 3 is carried out on a 25 cm x 0.46 cm (inside diameter) stainless steel column packed with Vydac IC302 ion Chromatography packing. The eluent is 1 mmol/L o-phthalic acid, and the ion is detected by conductivity detector. The detection limit in the presence chromatography is 5 μg/mL, the linear range is from 5 to 201 μg/mL, the linear correlation coefficient is 0.9994, respectively. The analysis accuracy is 2% for standard sample, and the detection limit is 51 μg/mL for HN 3 in the real sample. (authors)

  20. Secondary emission monitor for keV ion and antiproton beams

    CERN Document Server

    Sosa, Alejandro; Bravin, Enrico; Harasimowciz, Janusz; Welsch, C P

    2013-01-01

    Beam profile monitoring of low intensity keV ion and antiproton beams remains a challenging task. A Sec- ondary electron Emission Monitor (SEM) has been de- signed to measure profiles of beams with intensities below 107 and energies as low as 20 keV. The monitor is based on a two stage microchannel plate (MCP) and a phosphor screen facing a CCD camera. Its modular design allows two different operational setups. In this contribution we present the design of a prototype and discuss results from measurements with antiprotons at the AEgIS experiment at CERN. This is then used for a characterization of the monitor with regard to its possible future use at different facilities.

  1. Charging the quantum capacitance of graphene with a single biological ion channel.

    Science.gov (United States)

    Wang, Yung Yu; Pham, Ted D; Zand, Katayoun; Li, Jinfeng; Burke, Peter J

    2014-05-27

    The interaction of cell and organelle membranes (lipid bilayers) with nanoelectronics can enable new technologies to sense and measure electrophysiology in qualitatively new ways. To date, a variety of sensing devices have been demonstrated to measure membrane currents through macroscopic numbers of ion channels. However, nanoelectronic based sensing of single ion channel currents has been a challenge. Here, we report graphene-based field-effect transistors combined with supported lipid bilayers as a platform for measuring, for the first time, individual ion channel activity. We show that the supported lipid bilayers uniformly coat the single layer graphene surface, acting as a biomimetic barrier that insulates (both electrically and chemically) the graphene from the electrolyte environment. Upon introduction of pore-forming membrane proteins such as alamethicin and gramicidin A, current pulses are observed through the lipid bilayers from the graphene to the electrolyte, which charge the quantum capacitance of the graphene. This approach combines nanotechnology with electrophysiology to demonstrate qualitatively new ways of measuring ion channel currents.

  2. The single-ion anisotropy effects in the mixed-spin ternary-alloy

    Science.gov (United States)

    Albayrak, Erhan

    2018-04-01

    The effect of single-ion anisotropy on the thermal properties of the ternary-alloy in the form of ABpC1-p is investigated on the Bethe lattice (BL) in terms of exact recursion relations. The simulation on the BL consists of placing A atoms (spin-1/2) on the odd shells and randomly placing B (spin-3/2) or C (spin-5/2) atoms with concentrations p and 1 - p, respectively, on the even shells. The phase diagrams are calculated in possible planes spanned by the system parameters: temperature, single-ion anisotropy, concentration and ratio of the bilinear interaction parameters for z = 3 corresponding to the honeycomb lattice. It is found that the crystal field drives the system to the lowest possible state therefore reducing the temperatures of the critical lines in agreement with the literature.

  3. Modifying the properties of 4f single-ion magnets by peripheral ligand functionalisation

    DEFF Research Database (Denmark)

    Pedersen, Kasper Steen; Ungur, Liviu; Sigrist, Marc

    2014-01-01

    We study the ligand-field splittings and magnetic properties of three ErIII single-ion magnets which differ in the peripheral ligand sphere but exhibit similar first coordination spheres by inelastic neutron scattering (INS) and SQUID magnetometry. The INS spectra of the three compounds are profo......We study the ligand-field splittings and magnetic properties of three ErIII single-ion magnets which differ in the peripheral ligand sphere but exhibit similar first coordination spheres by inelastic neutron scattering (INS) and SQUID magnetometry. The INS spectra of the three compounds...... allows for the extraction of the sign and magnitude of all symmetry-allowed Stevens parameters. The parameter values and the energy spectrum derived from INS are compared to the results of state-of-the-art ab initio CASSCF calculations. Temperature-dependent alternating current (ac) susceptibility...... measurements suggest that the magnetisation relaxation in the investigated temperature range of 1.9 K

  4. Investigating change of properties in gallium ion irradiation patterned single-layer graphene

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Quan, E-mail: wangq@mail.ujs.edu.cn [School of Mechanical Engineering, Jiangsu University, Zhenjiang 212013 (China); Key Laboratory of Nanodevices and Applications, Suzhou Institute of Nano-Tech and Nano-Bionics, Chinese Academy of Sciences (China); Dong, Jinyao; Bai, Bing [School of Mechanical Engineering, Jiangsu University, Zhenjiang 212013 (China); Xie, Guoxin [State Key Laboratory of Tribology, Tsinghua University, Beijing 100084 (China)

    2016-10-14

    Besides its excellent physical properties, graphene promises to play a significant role in electronics with superior properties, which requires patterning of graphene for device integration. Here, we presented the changes in properties of single-layer graphene before and after patterning using gallium ion beam. Combined with Raman spectra of graphene, the scanning capacitance microscopy (SCM) image confirmed that a metal–insulator transition occurred after large doses of gallium ion irradiation. The changes in work function and Raman spectra of graphene indicated that the defect density increased as increasing the dose and a structural transition occurred during gallium ion irradiation. The patterning width of graphene presented an increasing trend due to the scattering influence of the impurities and the substrate. - Highlights: • The scanning capacitance microscopy image confirmed a metal–insulator transition occurred after large doses of gallium ion irradiation. • The changes indicated the defect density increased as increasing the dose and a structural transition occurred during gallium ion irradiation. • The patterning width of graphene presented a increasing trend due to the scattering influence of the impurities and the substrate.

  5. Investigating change of properties in gallium ion irradiation patterned single-layer graphene

    International Nuclear Information System (INIS)

    Wang, Quan; Dong, Jinyao; Bai, Bing; Xie, Guoxin

    2016-01-01

    Besides its excellent physical properties, graphene promises to play a significant role in electronics with superior properties, which requires patterning of graphene for device integration. Here, we presented the changes in properties of single-layer graphene before and after patterning using gallium ion beam. Combined with Raman spectra of graphene, the scanning capacitance microscopy (SCM) image confirmed that a metal–insulator transition occurred after large doses of gallium ion irradiation. The changes in work function and Raman spectra of graphene indicated that the defect density increased as increasing the dose and a structural transition occurred during gallium ion irradiation. The patterning width of graphene presented an increasing trend due to the scattering influence of the impurities and the substrate. - Highlights: • The scanning capacitance microscopy image confirmed a metal–insulator transition occurred after large doses of gallium ion irradiation. • The changes indicated the defect density increased as increasing the dose and a structural transition occurred during gallium ion irradiation. • The patterning width of graphene presented a increasing trend due to the scattering influence of the impurities and the substrate.

  6. Single-crate stand-alone CAMAC control system for a negative ion source test facility

    International Nuclear Information System (INIS)

    Juras, R.C.; Ziegler, N.F.

    1979-01-01

    A single-crate CAMAC system was configured to control a negative ion source development facility at ORNL and control software was written for the crate microcomputer. The software uses inputs from a touch panel and a shaft encoder to control the various operating parameters of the test facility and uses the touch panel to display the operating status. Communication to and from the equipment at ion source potential is accomplished over optical fibers from an ORNL-built CAMAC module. A receiver at ion source potential stores the transmitted data and some of these stored values are then used to control discrete parameters of the ion source (i.e., power supply on or off). Other stored values are sent to a multiplexed digital-to-analog converter to provide analog control signals. A transmitter at ion source potential transmits discrete status information and several channels of analog data from an analog-to-digital converter back to the ground-potential receiver where it is stored to be read and displayed by the software

  7. Impact of temperature on single event upset measurement by heavy ions in SRAM devices

    International Nuclear Information System (INIS)

    Liu Tianqi; Geng Chao; Zhang Zhangang; Gu Song; Tong Teng; Xi Kai; Hou Mingdong; Liu Jie; Zhao Fazhan; Liu Gang; Han Zhengsheng

    2014-01-01

    The temperature dependence of single event upset (SEU) measurement both in commercial bulk and silicon on insulator (SOI) static random access memories (SRAMs) has been investigated by experiment in the Heavy Ion Research Facility in Lanzhou (HIRFL). For commercial bulk SRAM, the SEU cross section measured by 12 C ions is very sensitive to the temperature. The temperature test of SEU in SOI SRAM was conducted by 209 Bi and 12 C ions, respectively, and the SEU cross sections display a remarkable growth with the elevated temperature for 12 C ions but keep constant for 209 Bi ions. The impact of temperature on SEU measurement was analyzed by Monte Carlo simulation. It is revealed that the SEU cross section is significantly affected by the temperature around the threshold linear energy transfer of SEU occurrence. As the SEU occurrence approaches saturation, the SEU cross section gradually exhibits less temperature dependency. Based on this result, the experimental data measured in HIRFL was analyzed, and then a reasonable method of predicting the on-orbit SEU rate was proposed. (semiconductor devices)

  8. Not Only Enthalpy: Large Entropy Contribution to Ion Permeation Barriers in Single-File Channels

    OpenAIRE

    Portella, Guillem; Hub, Jochen S.; Vesper, Martin D.; de Groot, Bert L.

    2008-01-01

    The effect of channel length on the barrier for potassium ion permeation through single-file channels has been studied by means of all-atom molecular dynamics simulations. Using series of peptidic gramicidin-like and simplified ring-structured channels, both embedded in model membranes, we obtained two distinct types of behavior: saturation of the central free energy barriers for peptidic channels and a linear increase in simplified ring-structured channels with increasing channel length. The...

  9. The rise of 3-d single-ion magnets in molecular magnetism: towards materials from molecules?

    Science.gov (United States)

    Frost, Jamie M; Harriman, Katie L M; Murugesu, Muralee

    2016-04-21

    Single-molecule magnets (SMMs) that contain one spin centre (so-called single-ion magnets) theoretically represent the smallest possible unit for spin-based electronic devices. The realisation of this and related technologies, depends on first being able to design systems with sufficiently large energy barriers to magnetisation reversal, U eff , and secondly, on being able to organise these molecules into addressable arrays. In recent years, significant progress has been made towards the former goal - principally as a result of efforts which have been directed towards studying complexes based on highly anisotropic lanthanide ions, such as Tb(iii) and Dy(iii). Since 2013 however, and the remarkable report by Long and co-workers of a linear Fe(i) system exhibiting U eff = 325 K, single-ion systems of transition metals have undergone something of a renaissance in the literature. Not only do they have important lessons to teach us about anisotropy and relaxation dynamics in the quest to enhance U eff , the ability to create strongly coupled spin systems potentially offers access to a whole of host of 1, 2 and 3-dimensional materials with interesting structural and physical properties. This perspective summarises recent progress in this rapidly expanding sub-genre of molecular magnetism from the viewpoint of the synthetic chemist, with a particular focus on the lessons that have so far been learned from single-ion magnets of the d-block, and, the future research directions which we feel are likely to emerge in the coming years.

  10. A generalized Jaynes-Cummings model: The relativistic parametric amplifier and a single trapped ion

    Energy Technology Data Exchange (ETDEWEB)

    Ojeda-Guillén, D., E-mail: dojedag@ipn.mx [Escuela Superior de Cómputo, Instituto Politécnico Nacional, Av. Juan de Dios Bátiz esq. Av. Miguel Othón de Mendizábal, Col. Lindavista, Delegación Gustavo A. Madero, C.P. 07738 Ciudad de México (Mexico); Mota, R. D. [Escuela Superior de Ingeniería Mecánica y Eléctrica, Unidad Culhuacán, Instituto Politécnico Nacional, Av. Santa Ana No. 1000, Col. San Francisco Culhuacán, Delegación Coyoacán, C.P. 04430 Ciudad de México (Mexico); Granados, V. D. [Escuela Superior de Física y Matemáticas, Instituto Politécnico Nacional, Ed. 9, Unidad Profesional Adolfo López Mateos, Delegación Gustavo A. Madero, C.P. 07738 Ciudad de México (Mexico)

    2016-06-15

    We introduce a generalization of the Jaynes-Cummings model and study some of its properties. We obtain the energy spectrum and eigenfunctions of this model by using the tilting transformation and the squeezed number states of the one-dimensional harmonic oscillator. As physical applications, we connect this new model to two important and novelty problems: the relativistic parametric amplifier and the quantum simulation of a single trapped ion.

  11. V79 cell survival after a single lithium ion nuclear traversal

    International Nuclear Information System (INIS)

    Pinto, M.; Buonanno, M.; Campajola, L.; Durante, M.; Grossi, G.; Publiese, G.; Scampoli, P.; Gialanella, G.; Manti, L.

    2003-01-01

    Full text: Biological studies on the effects of low doses of densely ionising radiation are highly influenced by the stochastic character of the energy deposition events. For several end-points, including clonogenic survival, to follow-up individual cells that have undergone an exactly determined number of charged particle traversals is highly desirable. While RBE-LET curves have been measured after conventional 'broad beam' irradiation with several ions of varying energies, the probability of cell survival after a single charged particle traversal has only been determined for accelerated protons and alpha particles, whereas the ability of single particle traversals at higher LET to cause clonogenic death is yet unknown. Recently, low dose studies have also shown phenomena of high interest, such as the hypersensitivity/induced radioresistance(HS/IRR) adaptive responses. However, for particles of high LET, even a single nuclear traversal may deliver an average dose to a single cell that may be beyond the dose region of the HS/IRR response. We ave set up an experimental apparatus for the determination of the inactivation cross section after an exactly known number of accelerated Lithium ions traversals (210 keV/micron when hitting the cell surface). Using a bio-stack approach (Pugliese et al, IJRB Oct;72(4):397-407 1997) LR115 thin nuclear track detectors have been employed for the direct visualisation of Lithium ion traversals in V79 cells nuclei that are labeled with Hoechst 33258. A computer software has been designed and implemented to control micro-meter movements of a motorised Marzhauser stage, mounted on a fluorescent microscope, for the acquisition of individual attached cell coordinates, type of traversal, as well as for re-visiting the registered coordinates for analysis of survivors. The V79 cell survival experiment after exactly known numbers of Lithium ions traversals is in progress, along with a classical 'broad beam' survival assay

  12. Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets of NAND Flash Memory

    Science.gov (United States)

    Chen, Dakai; Wilcox, Edward; Ladbury, Raymond; Kim, Hak; Phan, Anthony; Seidleck, Christina; LaBel, Kenneth

    2016-01-01

    We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found the single-event upset (SEU) cross section varied inversely with fluence. The SEU cross section decreased with increasing fluence. We attribute the effect to the variable upset sensitivities of the memory cells. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, heavy ion irradiation of devices with variable upset sensitivity distribution using typical fluence levels may underestimate the cross section and on-orbit event rate.

  13. Anisotropy effect of crater formation on single crystal silicon surface under intense pulsed ion beam irradiation

    Science.gov (United States)

    Shen, Jie; Yu, Xiao; Zhang, Jie; Zhong, Haowen; Cui, Xiaojun; Liang, Guoying; Yu, Xiang; Huang, Wanying; Shahid, Ijaz; Zhang, Xiaofu; Yan, Sha; Le, Xiaoyun

    2018-04-01

    Due to the induced extremely fast thermal and dynamic process, Intense Pulsed Ion Beam (IPIB) is widely applied in material processing, which can bring enhanced material performance and surface craters as well. To investigate the craters' formation mechanism, a specific model was built with Finite Element Methods (FEM) to simulate the thermal field on irradiated single crystal silicon. The direct evidence for the existence of the simulated 6-fold rotational symmetric thermal distribution was provided by electron microscope images obtained on single crystal silicon. The correlation of the experiment and simulation is of great importance to understand the interaction between IPIB and materials.

  14. Initial clinical evaluation of PET-based ion beam therapy monitoring under consideration of organ motion.

    Science.gov (United States)

    Kurz, Christopher; Bauer, Julia; Unholtz, Daniel; Richter, Daniel; Herfarth, Klaus; Debus, Jürgen; Parodi, Katia

    2016-02-01

    Intrafractional organ motion imposes considerable challenges to scanned ion beam therapy and demands for a thorough verification of the applied treatment. At the Heidelberg Ion-Beam Therapy Center (HIT), the scanned ion beam delivery is verified by means of postirradiation positron-emission-tomography (PET) imaging. This work presents a first clinical evaluation of PET-based treatment monitoring in ion beam therapy under consideration of target motion. Three patients with mobile liver lesions underwent scanned carbon ion irradiation at HIT and postirradiation PET/CT (x-ray-computed-tomography) imaging with a commercial scanner. Respiratory motion was recorded during irradiation and subsequent image acquisition. This enabled a time-resolved (4D) calculation of the expected irradiation-induced activity pattern and, for one patient where an additional 4D CT was acquired at the PET/CT scanner after treatment, a motion-compensated PET image reconstruction. For the other patients, PET data were reconstructed statically. To verify the treatment, calculated prediction and reconstructed measurement were compared with a focus on the ion beam range. Results in the current three patients suggest that for motion amplitudes in the order of 2 mm there is no benefit from incorporating respiratory motion information into PET-based treatment monitoring. For a target motion in the order of 10 mm, motion-related effects become more severe and a time-resolved modeling of the expected activity distribution can lead to an improved data interpretation if a sufficient number of true coincidences is detected. Benefits from motion-compensated PET image reconstruction could not be shown conclusively at the current stage. The feasibility of clinical PET-based treatment verification under consideration of organ motion has been shown for the first time. Improvements in noise-robust 4D PET image reconstruction are deemed necessary to enhance the clinical potential.

  15. Dose profile monitoring with carbon ions by means of prompt-gamma measurements

    Energy Technology Data Exchange (ETDEWEB)

    Testa, E. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France)], E-mail: e.testa@ipnl.in2p3.fr; Bajard, M.; Chevallier, M.; Dauvergne, D.; Le Foulher, F. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France); Freud, N.; Letang, J.M. [Institut National des Sciences Appliquees de Lyon, Laboratoire de Controle Non-Destructif par Rayonnements Ionisants (France); Poizat, J.C.; Ray, C.; Testa, M. [Institut de Physique Nucleaire de Lyon, Universite de Lyon, F-69003 Lyon, Universite Lyon 1 and IN2P3/CNRS, UMR 5822, F-69622 Villeurbanne (France)

    2009-03-15

    A key point in the quality control of ion therapy is real-time monitoring and imaging of the dose delivered to the patient. Among the possible signals that can be used to make such a monitoring, prompt gamma-rays issued from nuclear fragmentation are possible candidates, provided the correlation between the emission profile and the primary beam range can be established. By means of simultaneous energy and time-of-flight discrimination, we could measure the longitudinal profile of the prompt gamma-rays emitted by 73 MeV/u carbon ions stopping inside a PMMA target. This technique allowed us to minimize the shielding against neutrons and scattered gamma rays, and to find a good correlation between the prompt-gamma profile and the ion range. This profile was studied as a function of the observation angle. By extrapolating our results to higher energies and realistic detection efficiencies, we showed that prompt gamma-ray measurements make it feasible to control in real time the longitudinal dose during ion therapy treatments.

  16. Towards radiocarbon dating of single foraminifera with a gas ion source

    Science.gov (United States)

    Wacker, L.; Lippold, J.; Molnár, M.; Schulz, H.

    2013-01-01

    Carbonate shells from foraminifera are often analysed for radiocarbon to determine the age of deep-sea sediments or to assess radiocarbon reservoir ages. However, a single foraminiferal test typically contains only a few micrograms of carbon, while most laboratories require more than 100 μg for radiocarbon dating with an accelerator mass spectrometry (AMS) system. The collection of the required amount of foraminifera for a single analyses is therefore time consuming and not always possible. Here, we present a convenient method to measure the radiocarbon content of foraminifera using an AMS system fitted with a gas ion source. CO2 is liberated from 150 to 1150 μg of carbonate in septum sealed vials by acid decomposition of the carbonate. The CO2 is collected on a zeolite trap and subsequently transferred to a syringe from where it is delivered to the ion source. A sample of 400 μg (50 μg C) typically gives a 12C- ion source current of 10-15 μA over 20 min, yielding a measurement precision of less than 7 per mil for a modern sample. Using this method, we were able to date a single 560 μg Cibicides pseudoungerianus test at 14,030 ± 160 radiocarbon years. Only a minor modification to our existing gas handling system was required and the system is fully automatable to further reduce the effort involved for sample preparation.

  17. Towards radiocarbon dating of single foraminifera with a gas ion source

    International Nuclear Information System (INIS)

    Wacker, L.; Lippold, J.; Molnár, M.; Schulz, H.

    2013-01-01

    Carbonate shells from foraminifera are often analysed for radiocarbon to determine the age of deep-sea sediments or to assess radiocarbon reservoir ages. However, a single foraminiferal test typically contains only a few micrograms of carbon, while most laboratories require more than 100 μg for radiocarbon dating with an accelerator mass spectrometry (AMS) system. The collection of the required amount of foraminifera for a single analyses is therefore time consuming and not always possible. Here, we present a convenient method to measure the radiocarbon content of foraminifera using an AMS system fitted with a gas ion source. CO 2 is liberated from 150 to 1150 μg of carbonate in septum sealed vials by acid decomposition of the carbonate. The CO 2 is collected on a zeolite trap and subsequently transferred to a syringe from where it is delivered to the ion source. A sample of 400 μg (50 μg C) typically gives a 12 C − ion source current of 10–15 μA over 20 min, yielding a measurement precision of less than 7 per mil for a modern sample. Using this method, we were able to date a single 560 μg Cibicides pseudoungerianus test at 14,030 ± 160 radiocarbon years. Only a minor modification to our existing gas handling system was required and the system is fully automatable to further reduce the effort involved for sample preparation.

  18. Towards radiocarbon dating of single foraminifera with a gas ion source

    Energy Technology Data Exchange (ETDEWEB)

    Wacker, L., E-mail: wacker@phys.ethz.ch [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Lippold, J. [Heidelberg Academy of Sciences, 69120 Heidelberg (Germany); Molnar, M. [Laboratory of Ion Beam Physics, ETH Zurich, 8093 Zurich (Switzerland); Institute of Nuclear Research, Hungarian Academy of Sciences, 4026 Debrecen (Hungary); Schulz, H. [Institute for Geosciencies, University of Tuebingen, 72076 Tuebingen (Germany)

    2013-01-15

    Carbonate shells from foraminifera are often analysed for radiocarbon to determine the age of deep-sea sediments or to assess radiocarbon reservoir ages. However, a single foraminiferal test typically contains only a few micrograms of carbon, while most laboratories require more than 100 {mu}g for radiocarbon dating with an accelerator mass spectrometry (AMS) system. The collection of the required amount of foraminifera for a single analyses is therefore time consuming and not always possible. Here, we present a convenient method to measure the radiocarbon content of foraminifera using an AMS system fitted with a gas ion source. CO{sub 2} is liberated from 150 to 1150 {mu}g of carbonate in septum sealed vials by acid decomposition of the carbonate. The CO{sub 2} is collected on a zeolite trap and subsequently transferred to a syringe from where it is delivered to the ion source. A sample of 400 {mu}g (50 {mu}g C) typically gives a {sup 12}C{sup -} ion source current of 10-15 {mu}A over 20 min, yielding a measurement precision of less than 7 per mil for a modern sample. Using this method, we were able to date a single 560 {mu}g Cibicides pseudoungerianus test at 14,030 {+-} 160 radiocarbon years. Only a minor modification to our existing gas handling system was required and the system is fully automatable to further reduce the effort involved for sample preparation.

  19. Evaluation of an empirical monitor output estimation in carbon ion radiotherapy.

    Science.gov (United States)

    Matsumura, Akihiko; Yusa, Ken; Kanai, Tatsuaki; Mizota, Manabu; Ohno, Tatsuya; Nakano, Takashi

    2015-09-01

    A conventional broad beam method is applied to carbon ion radiotherapy at Gunma University Heavy Ion Medical Center. According to this method, accelerated carbon ions are scattered by various beam line devices to form 3D dose distribution. The physical dose per monitor unit (d/MU) at the isocenter, therefore, depends on beam line parameters and should be calibrated by a measurement in clinical practice. This study aims to develop a calculation algorithm for d/MU using beam line parameters. Two major factors, the range shifter dependence and the field aperture effect, are measured via PinPoint chamber in a water phantom, which is an identical setup as that used for monitor calibration in clinical practice. An empirical monitor calibration method based on measurement results is developed using a simple algorithm utilizing a linear function and a double Gaussian pencil beam distribution to express the range shifter dependence and the field aperture effect. The range shifter dependence and the field aperture effect are evaluated to have errors of 0.2% and 0.5%, respectively. The proposed method has successfully estimated d/MU with a difference of less than 1% with respect to the measurement results. Taking the measurement deviation of about 0.3% into account, this result is sufficiently accurate for clinical applications. An empirical procedure to estimate d/MU with a simple algorithm is established in this research. This procedure allows them to use the beam time for more treatments, quality assurances, and other research endeavors.

  20. Lung Injury; Relates to Real-Time Endoscopic Monitoring of Single Cells Respiratory Health in Lung

    Science.gov (United States)

    2017-09-01

    AWARD NUMBER: W81XWH-16-1-0253 TITLE: Lung Injury; Relates to Real- Time Endoscopic Monitoring of Single Cells Respiratory Health in Lung...response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and...Sep 2016 - 31 Aug 2017 5a. CONTRACT NUMBER 4. TITLE AND SUBTITLE Lung Injury; Relates to Real- Time Endoscopic Monitoring of Single Cells Respiratory

  1. Single event monitoring system based on Java 3D and XML data binding

    International Nuclear Information System (INIS)

    Wang Liang; Chinese Academy of Sciences, Beijing; Zhu Kejun; Zhao Jingwei

    2007-01-01

    Online single event monitoring is important to BESIII DAQ System. Java3D is extension of Java Language in 3D technology, XML data binding is more efficient to handle XML document than SAX and DOM. This paper mainly introduce the implementation of BESIII single event monitoring system with Java3D and XML data binding, and interface for track fitting software with JNI technology. (authors)

  2. Eddy current sensor for in-situ monitoring of swelling of Li-ion prismatic cells

    Science.gov (United States)

    Plotnikov, Yuri; Karp, Jason; Knobloch, Aaron; Kapusta, Chris; Lin, David

    2015-03-01

    In-situ monitoring an on-board rechargeable battery in hybrid cars can be used to ensure a long operating life of the battery and safe operation of the vehicle. Intercalations of ions in the electrode material during charge and discharge of a Lithium Ion battery cause periodic stress and strain of the electrode materials that can ultimately lead to fatigue resulting in capacity loss and potential battery failure. Currently this process is not monitored directly on the cells. This work is focused on development technologies that would quantify battery swelling and provide in-situ monitoring for onboard vehicle applications. Several rounds of tests have been performed to spatially characterize cell expansion of a 5 Ah cell with a nickel/manganese/cobalt-oxide cathode (Sanyo, Japan) used by Ford in their Fusion HEV battery pack. A collaborative team of researchers from GE and the University of Michigan has characterized the free expansion of these cells to be in the range of 100×125 microns (1% of total cell thickness) at the center point of the cell. GE proposed to use a thin eddy current (EC) coil to monitor these expansions on the cells while inside the package. The photolithography manufacturing process previously developed for EC arrays for detecting cracks in aircraft engine components was used to build test coils for gap monitoring. These sensors are thin enough to be placed safely between neighboring cells and capable of monitoring small variations in the gap between the cells. Preliminary investigations showed that these coils can be less than 100 micron thick and have sufficient sensitivity in a range from 0 to 2 mm. Laboratory tests revealed good correlation between EC and optical gap measurements in the desired range. Further technology development could lead to establishing a sensor network for a low cost solution for the in-situ monitoring of cell swelling during battery operation.

  3. Designing Single-Ion Magnets and Phosphorescent Materials with 1-Methylimidazole-5-carboxylate and Transition-Metal Ions.

    Science.gov (United States)

    García-Valdivia, Antonio A; Seco, Jose M; Cepeda, Javier; Rodríguez-Diéguez, Antonio

    2017-11-20

    Detailed structural, magnetic, and photoluminescence (PL) characterization of four new compounds based on 1-methylimidazole-5-carboxylate (mimc) ligand and transition metal ions, namely [Ni(mimc) 2 (H 2 O) 4 ] (1), [Co(μ-mimc) 2 ] n (2), {[Cu 2 (μ-mimc) 4 (H 2 O)]·2H 2 O} n (3), and [Cd(μ-mimc) 2 (H 2 O)] n (4) is reported. The structural diversity found in the family of compounds derives from the coordination versatility of the ligand, which coordinates as a terminal ligand to give a supramolecular network of monomeric entities in 1 or acts as a bridging linker to build isoreticular 2D coordination polymers (CPs) in 2-4. Magnetic direct-current (dc) susceptibility data have been measured for compounds 1-3 to analyze the exchange interactions among paramagnetic centers, which have been indeed supported by calculations based on broken symmetry (BS) and density functional theory (DFT) methodology. The temperature dependence of susceptibility and magnetization data of 2 are indicative of easy-plane anisotropy (D = +12.9 cm -1 , E = +0.5 cm -1 ) that involves a bistable M s = ±1/2 ground state. Alternating-current (ac) susceptibility curves exhibit field-induced single-ion magnet (SIM) behavior that occurs below 14 K, which is characterized by two spin relaxation processes of distinct nature: fast relaxation of single ions proceeding through multiple mechanisms (U eff = 26 K) and a slow relaxation attributed to interactions along the polymeric crystal building. Exhaustive PL analysis of compound 4 in the solid state confirms low-temperature phosphorescent green emission consisting of radiative lifetimes in the range of 0.25-0.43 s, which explains the afterglow observed during about 1 s after the removal of the UV source. Time-dependent DFT and computational calculations to estimate phosphorescent vertical transitions have been also employed to provide an accurate description of the PL performance of this long-lasting phosphor.

  4. Fast detection of narcotics by single photon ionization mass spectrometry and laser ion mobility spectrometry

    Science.gov (United States)

    Laudien, Robert; Schultze, Rainer; Wieser, Jochen

    2010-10-01

    In this contribution two analytical devices for the fast detection of security-relevant substances like narcotics and explosives are presented. One system is based on an ion trap mass spectrometer (ITMS) with single photon ionization (SPI). This soft ionization technique, unlike electron impact ionization (EI), reduces unwanted fragment ions in the mass spectra allowing the clear determination of characteristic (usually molecular) ions. Their enrichment in the ion trap and identification by tandem MS investigations (MS/MS) enables the detection of the target substances in complex matrices at low concentrations without time-consuming sample preparation. For SPI an electron beam pumped excimer light source of own fabrication (E-Lux) is used. The SPI-ITMS system was characterized by the analytical study of different drugs like cannabis, heroin, cocaine, amphetamines, and some precursors. Additionally, it was successfully tested on-site in a closed illegal drug laboratory, where low quantities of MDMA could be directly detected in samples from floors, walls and lab equipments. The second analytical system is based on an ion mobility (IM) spectrometer with resonant multiphoton ionization (REMPI). With the frequency quadrupled Nd:YAG laser (266 nm), used for ionization, a selective and sensitive detection of aromatic compounds is possible. By application of suited aromatic dopants, in addition, also non-aromatic polar compounds are accessible by ion molecule reactions like proton transfer or complex formation. Selected drug precursors could be successfully detected with this device as well, qualifying it to a lower-priced alternative or useful supplement of the SPI-ITMS system for security analysis.

  5. An Optical Fiber-Based Sensor Array for the Monitoring of Zinc and Copper Ions in Aqueous Environments

    Directory of Open Access Journals (Sweden)

    Steven Kopitzke

    2014-02-01

    Full Text Available Copper and zinc are elements commonly used in industrial applications as aqueous solutions. Before the solutions can be discharged into civil or native waterways, waste treatment processes must be undertaken to ensure compliance with government guidelines restricting the concentration of ions discharged in solution. While currently there are methods of analysis available to monitor these solutions, each method has disadvantages, be it high costs, inaccuracy, and/or being time-consuming. In this work, a new optical fiber-based platform capable of providing fast and accurate results when performing solution analysis for these metals is described. Fluorescent compounds that exhibit a high sensitivity and selectivity for either zinc or copper have been employed for fabricating the sensors. These sensors demonstrated sub-part-per-million detection limits, 30-second response times, and the ability to analyze samples with an average error of under 10%. The inclusion of a fluorescent compound as a reference material to compensate for fluctuations from pulsed excitation sources has further increased the reliability and accuracy of each sensor. Finally, after developing sensors capable of monitoring zinc and copper individually, these sensors are combined to form a single optical fiber sensor array capable of simultaneously monitoring concentration changes in zinc and copper in aqueous environments.

  6. Effect of swift heavy ion irradiation on single- and multiwalled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Olejniczak, Andrzej, E-mail: aolejnic@chem.uni.torun.pl [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Faculty of Chemistry, Nicolaus Copernicus University, ul. Gagarina 7, 87-100 Toruń (Poland); Skuratov, Vladimir A. [Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation)

    2014-05-01

    The effect of irradiation with swift heavy ions on the structure and properties of carbon nanotubes was investigated by Raman spectroscopy. It was found that disordering of the system occurred mainly at the surface. No ordering phenomena have been observed over a whole range of both fluences and electronic stopping powers studied. The disorder parameter (i.e., the ratio of the D and G band intensities (I{sub D}/I{sub G})) increases non-linearly with the irradiation dose, showing a tendency to saturate at high fluences. The increase in the disorder parameter upon irradiation was proportional to the square root of the ion fluence. The radiation stability of the few-walled nanotubes was ca. 1.6 higher than that of the single-walled ones. The irradiation with both the Xe and Kr ions leads to essentially the same increase in the I{sub D}/I{sub G} ratio with respect to the deposited electronic energy density. In the case of the Ar ion irradiation, the observed increase in the I{sub D}/I{sub G} ratio is much lower, suggesting that the electronic stopping power threshold for defects creation in carbon nanotubes is lower than that for graphite.

  7. Trapped-ion anomalous diffusion coefficient on the basis of single mode saturation

    International Nuclear Information System (INIS)

    Koshi, Yuji; Hatayama, Akiyoshi; Ogasawara, Masatada.

    1982-03-01

    Expressions of the anomalous diffusion coefficient due to the dissipative trapped ion instability (DTII) are derived for the case with and without the effect of magnetic shear. Derivation is made by taking into account of the single mode saturation of the DTII previously obtained numerically. In the absence of the shear effect, the diffusion coefficient is proportional to #betta#sub(i)a 2 (#betta#sub(i) is the effective collision frequency of the trapped ions and a is the minor radius of a torus) and is much larger than the neoclassical ion heat conductivity. In the presence of the shear effect, the diffusion coefficient is much smaller than the Kadomtsev and Pogutse's value and is the same order of magnitude as the neoclassical ion heat conductivity. Dependences of the diffusion coefficient on the temperature and on the total particle number density are rather complicated due to the additional spectral cut-off, which is introduced to regularize the short wavelength modes in the numerical analysis. (author)

  8. Live cell imaging combined with high-energy single-ion microbeam

    International Nuclear Information System (INIS)

    Guo, Na; Du, Guanghua; Liu, Wenjing; Wu, Ruqun; Wei, Junzhe; Guo, Jinlong; Chen, Hao

    2016-01-01

    DNA strand breaks can lead to cell carcinogenesis or cell death if not repaired rapidly and efficiently. An online live cell imaging system was established at the high energy microbeam facility at the Institute of Modern Physics to study early and fast cellular response to DNA damage after high linear energy transfer ion radiation. The HT1080 cells expressing XRCC1-RFP were irradiated with single high energy nickel ions, and time-lapse images of the irradiated cells were obtained online. The live cell imaging analysis shows that strand-break repair protein XRCC1 was recruited to the ion hit position within 20 s in the cells and formed bright foci in the cell nucleus. The fast recruitment of XRCC1 at the ion hits reached a maximum at about 200 s post-irradiation and then was followed by a slower release into the nucleoplasm. The measured dual-exponential kinetics of XRCC1 protein are consistent with the proposed consecutive reaction model, and the measurements obtained that the reaction rate constant of the XRCC1 recruitment to DNA strand break is 1.2 × 10 −3 s −1 and the reaction rate constant of the XRCC1 release from the break-XRCC1 complex is 1.2 × 10 −2 s −1 .

  9. Live cell imaging combined with high-energy single-ion microbeam

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Na; Du, Guanghua, E-mail: gh-du@impcas.ac.cn; Liu, Wenjing; Wu, Ruqun; Wei, Junzhe [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou (China); Guo, Jinlong [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou (China); Northwest Normal University, Lanzhou (China); Chen, Hao [Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou (China); Institute of Nuclear Science and Technology, University of Lanzhou, Lanzhou (China)

    2016-03-15

    DNA strand breaks can lead to cell carcinogenesis or cell death if not repaired rapidly and efficiently. An online live cell imaging system was established at the high energy microbeam facility at the Institute of Modern Physics to study early and fast cellular response to DNA damage after high linear energy transfer ion radiation. The HT1080 cells expressing XRCC1-RFP were irradiated with single high energy nickel ions, and time-lapse images of the irradiated cells were obtained online. The live cell imaging analysis shows that strand-break repair protein XRCC1 was recruited to the ion hit position within 20 s in the cells and formed bright foci in the cell nucleus. The fast recruitment of XRCC1 at the ion hits reached a maximum at about 200 s post-irradiation and then was followed by a slower release into the nucleoplasm. The measured dual-exponential kinetics of XRCC1 protein are consistent with the proposed consecutive reaction model, and the measurements obtained that the reaction rate constant of the XRCC1 recruitment to DNA strand break is 1.2 × 10{sup −3} s{sup −1} and the reaction rate constant of the XRCC1 release from the break-XRCC1 complex is 1.2 × 10{sup −2} s{sup −1}.

  10. Live cell imaging combined with high-energy single-ion microbeam

    Science.gov (United States)

    Guo, Na; Du, Guanghua; Liu, Wenjing; Guo, Jinlong; Wu, Ruqun; Chen, Hao; Wei, Junzhe

    2016-03-01

    DNA strand breaks can lead to cell carcinogenesis or cell death if not repaired rapidly and efficiently. An online live cell imaging system was established at the high energy microbeam facility at the Institute of Modern Physics to study early and fast cellular response to DNA damage after high linear energy transfer ion radiation. The HT1080 cells expressing XRCC1-RFP were irradiated with single high energy nickel ions, and time-lapse images of the irradiated cells were obtained online. The live cell imaging analysis shows that strand-break repair protein XRCC1 was recruited to the ion hit position within 20 s in the cells and formed bright foci in the cell nucleus. The fast recruitment of XRCC1 at the ion hits reached a maximum at about 200 s post-irradiation and then was followed by a slower release into the nucleoplasm. The measured dual-exponential kinetics of XRCC1 protein are consistent with the proposed consecutive reaction model, and the measurements obtained that the reaction rate constant of the XRCC1 recruitment to DNA strand break is 1.2 × 10-3 s-1 and the reaction rate constant of the XRCC1 release from the break-XRCC1 complex is 1.2 × 10-2 s-1.

  11. Scattering of atomic and molecular ions from single crystal surfaces of Cu, Ag and Fe

    International Nuclear Information System (INIS)

    Zoest, J.M. van.

    1986-01-01

    This thesis deals with analysis of crystal surfaces of Cu, Ag and Fe with Low Energy Ion scattering Spectroscopy (LEIS). Different atomic and molecular ions with fixed energies below 7 keV are scattered by a metal single crystal (with adsorbates). The energy and direction of the scattered particles are analysed for different selected charge states. In that way information can be obtained concerning the composition and atomic and electronic structure of the single crystal surface. Energy spectra contain information on the composition of the surface, while structural atomic information is obtained by direction measurements (photograms). In Ch.1 a description is given of the experimental equipment, in Ch.2 a characterization of the LEIS method. Ch.3 deals with the neutralization of keV-ions in surface scattering. Two different ways of data interpretation are presented. First a model is treated in which the observed directional dependence of neutralization action of the first atom layer of the surface is presented by a laterally varying thickness of the neutralizing layer. Secondly it is shown that the data can be reproduced by a more realistic, physical model based on atomic transition matrix elements. In Ch.4 the low energy hydrogen scattering is described. The study of the dissociation of H 2 + at an Ag surface r0230ted in a model based on electronic dissociation, initialized by electron capture into a repulsive (molecular) state. In Ch.5 finally the method is applied to the investigation of the surface structure of oxidized Fe. (Auth.)

  12. Electrochemical lithium-ion storage properties of quinone molecules encapsulated in single-walled carbon nanotubes.

    Science.gov (United States)

    Ishii, Yosuke; Tashiro, Kosuke; Hosoe, Kento; Al-Zubaidi, Ayar; Kawasaki, Shinji

    2016-04-21

    We investigated the electrochemical lithium-ion storage properties of 9,10-anthraquinone (AQ) and 9,10-phenanthrenequinone (PhQ) molecules encapsulated in the inner hollow core of single-walled carbon nanotubes (SWCNTs). The structural properties of the obtained encapsulated systems were characterized by electron microscopy, synchrotron powder X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy and Raman spectroscopy. We found that almost all quinone molecules encapsulated in the SWCNTs can store Li-ions reversibly. Interestingly, the undesired capacity fading, which comes from the dissolution of quinone molecules into the electrolyte, was suppressed by the encapsulation. It was also found that the overpotential of AQ was decreased by the encapsulation, probably due to the high-electric conductivity of SWCNTs.

  13. Swift heavy ion induced modifications of single walled carbon nanotube thin films

    Energy Technology Data Exchange (ETDEWEB)

    Vishalli, E-mail: vishalli_2008@yahoo.com [Department of Physics, Panjab University, Chandigarh 160014 (India); Raina, K.K. [Materials Research Laboratory, School of Physics and Materials Science, Thapar University, P.O. Box 32, Patiala 147004, Punjab (India); Avasthi, D.K. [Materials Science Group, Inter University Accelerator Centre, Aruna Asaf Ali Marg, P.O. Box 10502, New Delhi 110067 (India); Srivastava, Alok [Department of Chemistry, Panjab University, Chandigarh 160014 (India); Dharamvir, Keya [Department of Physics, Panjab University, Chandigarh 160014 (India)

    2016-04-15

    Thin films of single walled carbon nanotubes (SWCNTs) were prepared by Langmuir–Blodgett method and irradiated with swift heavy ions, carbon and nickel each of energy 60 MeV. The ion beams have different electronic energy loss (S{sub e}) values and the samples were exposed to various irradiation doses. The irradiated films were characterized using Raman and optical absorption spectroscopy. Raman spectroscopy results indicate the competing processes of defect creation and healing (annealing) of SWCNTs at lower fluences, while at higher fluences defect creation or damage dominates. In UV–Vis–NIR spectroscopy we find that there is decrease in the intensity of characteristic peaks with every increasing fluence, indicating decrease in the optically active states with irradiation.

  14. Investigation on optical absorption properties of ion irradiated single walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Vishalli,, E-mail: vishalli-2008@yahoo.com; Dharamvir, Keya, E-mail: keya@pu.ac.in [Department of Physics, Panjab University, Chandigarh (India); Kaur, Ramneek; Raina, K. K. [Materials Research Laboratory, School of Physics and Materials Science, Thapar University, Patiala (India); Avasthi, D. K. [Materials Science Group, Inter University Accelerator Centre, ArunaAsaf Ali Marg, NewDelhi (India); Jeet, Kiran [Electron Microscopy and Nanoscience laboratory, Punjab Agriculture University, Ludhiana (India)

    2015-08-28

    In the present study change in the optical absorption properties of single walled carbon nanotubes (SWCNTs) under nickel ion (60 MeV) irradiation at various fluences has been investigated. Langmuir Blodgett technique is used to deposit SWCNT thin film of uniform thickness. AFM analysis shows a network of interconnected bundles of nanotubes. UV-Vis-NIR absorption spectra indicate that the sample mainly contain SWCNTs of semiconducting nature. It has been found in absorption spectra that there is decrease in the intensity of the characteristic SWCNT peaks with increase in fluence. At fluence value 1×10{sup 14} ions/cm{sup 2} there is almost complete suppression of the characteristic SWCNTs peaks.The decrease in the optical absorption with increase in fluence is due to the increase in the disorder in the system which leads to the decrease in optically active states.

  15. Energy transduction and signal averaging of fluctuating electric fields by a single protein ion channel.

    Science.gov (United States)

    Verdia-Baguena, C; Gomez, V; Cervera, J; Ramirez, P; Mafe, S

    2016-12-21

    We demonstrate the electrical rectification and signal averaging of fluctuating signals using a biological nanostructure in aqueous solution: a single protein ion channel inserted in the lipid bilayer characteristic of cell membranes. The conversion of oscillating, zero time-average potentials into directional currents permits charging of a load capacitor to significant steady-state voltages within a few minutes in the case of the outer membrane porin F (OmpF) protein, a bacterial channel of Escherichia coli. The experiments and simulations show signal averaging effects at a more fundamental level than the traditional cell and tissue scales, which are characterized by ensembles of many ion channels operating simultaneously. The results also suggest signal transduction schemes with bio-electronic interfaces and ionic circuits where soft matter nanodiodes can be coupled to conventional electronic elements.

  16. An efficient single-step scheme for manipulating quantum information of two trapped ions beyond the Lamb-Dicke limit

    International Nuclear Information System (INIS)

    Wei, L.F.; Nori, Franco

    2003-01-01

    Based on the exact conditional quantum dynamics for a two-ion system, we propose an efficient single-step scheme for coherently manipulating quantum information of two trapped cold ions by using a pair of synchronous laser pulses. Neither the auxiliary atomic level nor the Lamb-Dicke approximation are needed

  17. Ion beam induced surface graphitization of CVD diamond for x-ray beam position monitor applications

    International Nuclear Information System (INIS)

    Liu, Chian; Shu, D.; Kuzay, T.M.; Wen, L.; Melendres, C.A.; Argonne National Lab., IL

    1996-01-01

    The Advanced Photon Source at ANL is a third-generation synchrotron facility that generates powerful x-ray beams on its undulator beamlines. It is important to know the position and angle of the x- ray beam during experiments. Due to very high heat flux levels, several patented x-ray beam position monitors (XBPM) exploiting chemical vapor deposition (CVD) diamond have been developed. These XBPMs have a thin layer of low-atomic-mass metallic coating so that photoemission from the x rays generate a minute but measurable current for position determination. Graphitization of the CVD diamond surface creates a very thin, intrinsic and conducting layer that can stand much higher temperatures and minimal x-ray transmission losses compared to the coated metallic layers. In this paper, a laboratory sputter ion source was used to transform selected surfaces of a CVD diamond substrate into graphite. The effect of 1-5 keV argon ion bombardment on CVD diamond surfaces at various target temperatures from 200 to 500 C was studied using Auger electron spectroscopy and in-situ electrical resistivity measurements. Graphitization after the ion bombardment has been confirmed and optimum conditions for graphitization studied. Raman spectroscopy was used to identify the overall diamond structure in the bulk of CVD diamond substrate after the ion bombardments. It was found that target temperature plays an important role in stability and electrical conductivity of the irradiated CVD diamonds

  18. Monitoring and Manipulating Motions of Single Molecules/Nanoparticles

    Science.gov (United States)

    Chen, Fang

    This dissertation has two main research components: 1. the study of mass transport in confined environments; 2. the effort toward driving a molecular car on a solid surface. Understanding mass transport processes, e.g., diffusion, migration, and adsorption/desorption in confined space is important not only to fundamental sciences but also to advanced applications. So far, they are poorly understood because of technical challenges: insufficient spatial and/or temporal resolutions. In this dissertation, we made efforts toward understanding molecular/particular dynamics in confined space by combining a recently developed super resolution technique, stimulated depletion emission microscopy (STED), with the high temporal resolution technique, fluorescence correlation spectroscopy (FCS). We first explored the feasibility of using conventional FCS to study diffusion in a model confined space: cylindrical pores. Since there is no analytical solution to solve the autocorrelation function (ACF) in confined space, we simulated single particle diffusion in hundred-nanometer pores using Monte Carlo simulation. We found that confined 2D diffusion and unconfined 1D diffusion dynamics are separated in both intensity traces and autocorrelation functions, which gives a new opportunity to extract the axial diffusion coefficient in cylindrical pores. We then experimentally studied 45 nm particles diffusing in 300 nm alumina pores. The acquired axial diffusion coefficient is consistent with the expected value. Conventional confocal FCS is insufficient to resolve lateral diffusion in confined space because of the diffraction limit in spatial resolution. To pave the way of using STED microscopy to study the anisotropic diffusion in confined space, we theoretically investigated STED-FCS in cylindrical pores. It showed that by reducing the spatial resolution from 250 nm to 50 nm in STED microscopy, we would be able to determine both lateral and axial diffusion coefficients in hundred

  19. An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry

    International Nuclear Information System (INIS)

    Wang, Yang; Liu, Fang; Li, Peng; He, Chengwei; Wang, Ruibing; Su, Huanxing; Wan, Jian-Bo

    2016-01-01

    Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies. - Highlights: • An UHPLC/Q-TOF tsMIM MS-based pseudotargeted metabolomics was proposed. • Compared to full scan, the improved method exhibits better repeatability and a wider linear range. • The proposed method could achieve pseudotargeted analysis on one UHPLC/Q-TOF/MS instrument. • The developed method was successfully used to discover biomarkers for alcohol-induced liver injury.

  20. An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Wang, Yang; Liu, Fang; Li, Peng; He, Chengwei; Wang, Ruibing; Su, Huanxing; Wan, Jian-Bo

    2016-07-13

    Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. An improved pseudotargeted metabolomics approach using multiple ion monitoring with time-staggered ion lists based on ultra-high performance liquid chromatography/quadrupole time-of-flight mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Yang; Liu, Fang; Li, Peng; He, Chengwei; Wang, Ruibing; Su, Huanxing; Wan, Jian-Bo, E-mail: jbwan@umac.mo

    2016-07-13

    Pseudotargeted metabolomics is a novel strategy integrating the advantages of both untargeted and targeted methods. The conventional pseudotargeted metabolomics required two MS instruments, i.e., ultra-high performance liquid chromatography/quadrupole-time- of-flight mass spectrometry (UHPLC/Q-TOF MS) and UHPLC/triple quadrupole mass spectrometry (UHPLC/QQQ-MS), which makes method transformation inevitable. Furthermore, the picking of ion pairs from thousands of candidates and the swapping of the data between two instruments are the most labor-intensive steps, which greatly limit its application in metabolomic analysis. In the present study, we proposed an improved pseudotargeted metabolomics method that could be achieved on an UHPLC/Q-TOF/MS instrument operated in the multiple ion monitoring (MIM) mode with time-staggered ion lists (tsMIM). Full scan-based untargeted analysis was applied to extract the target ions. After peak alignment and ion fusion, a stepwise ion picking procedure was used to generate the ion lists for subsequent single MIM and tsMIM. The UHPLC/Q-TOF tsMIM MS-based pseudotargeted approach exhibited better repeatability and a wider linear range than the UHPLC/Q-TOF MS-based untargeted metabolomics method. Compared to the single MIM mode, the tsMIM significantly increased the coverage of the metabolites detected. The newly developed method was successfully applied to discover plasma biomarkers for alcohol-induced liver injury in mice, which indicated its practicability and great potential in future metabolomics studies. - Highlights: • An UHPLC/Q-TOF tsMIM MS-based pseudotargeted metabolomics was proposed. • Compared to full scan, the improved method exhibits better repeatability and a wider linear range. • The proposed method could achieve pseudotargeted analysis on one UHPLC/Q-TOF/MS instrument. • The developed method was successfully used to discover biomarkers for alcohol-induced liver injury.

  2. Production of Inorganic Thin Scintillating Films for Ion Beam Monitoring Devices

    CERN Document Server

    Re, Maurizio; Cosentino, Luigi; Cuttone, Giacomo; Finocchiaro, Paolo; Hermanne, Alex; Lojacono, Pietro A; Ma, YingJun; Thienpont, Hugo; Van Erps, Jurgen; Vervaeke, Michael; Volckaerts, Bart; Vynck, Pedro

    2005-01-01

    In this work we present the development of beam monitoring devices consisting of thin CsI(Tl) films deposited on Aluminium support layers. The light emitted by the scintillating layer during the beam irradiation is measured by a CCD-camera. In a first prototype a thin Aluminium support layer of 6 micron allows the ion beam to easily pass through without significant energy loss and scattering effects. Therefore it turns out to be a non-destructive monitoring device to characterize on-line beam shape and beam position without interfering with the rest of the irradiation process. A second device consists of an Aluminium support layer which is thick enough to completely stop the impinging ions allowing to monitor at the same time the beam profile and the beam current intensity. Some samples have been coated by a 100 Å protective layer to prevent the film damage by atmosphere exposition. In this contribution we present our experimental results obtained by irradiating the samples with proton beams at 8.3 and 62 Me...

  3. Numerical simulation study into the effect of a single heavy ion on a sub-micron CMOS device

    International Nuclear Information System (INIS)

    Detcheverry, C.; Lorfevre, E.; Bruguier, G.; Palau, J.M.; Gasiot, J.; Ecoffet, R.

    1997-01-01

    This article discusses coupling between the MEDICI component simulator and the SPICE circuit simulator to study single-event-upset phenomena caused by a single ion on a 0.6 μm CMOS device. Results conforming closely to experimental values were obtained by adopting an appropriate mesh size, a hydrodynamic charge transport model (rather than a diffusion-conduction model), and realistic simulation of photon-induced carrier generation, to accurately model the ion passage and trajectory. (authors)

  4. Development of a single ion micro-irradiation facility for experimental radiobiology at cell level

    International Nuclear Information System (INIS)

    Barberet, Ph.

    2003-10-01

    A micro-irradiation device has been developed for radiobiology applications at the scale of the cell. This device is based on an upgrade of an existing micro-beam line that was already able to deliver a 1 to 3 MeV proton or alpha beam of low intensity and whose space resolution is lower than 1 micrometer in vacuum. The important part of this work has been the development of an irradiation stage designed to fit on the micro-probe and able to deliver ions in the air with an absolute accuracy of a few micrometers. A program has been set up to monitor the complete irradiation line in testing and in automatic irradiation operating phases. Simulation tools based on Monte-Carlo calculations have been validated through comparisons with experimental data particularly in the field of spatial resolution and of the number of ions delivered. The promising results show the possibility in a near future to use this tool to study the response of cells to very low irradiation doses down to the extreme limit of one ion per cell

  5. Single-Qubit-Gate Error below 0.0001 in a Trapped Ion

    Science.gov (United States)

    2011-01-01

    nuclear spins in liquid-state nuclear-magnetic resonance experiments [6] and with neutral atoms confined in optical lattices [7]; here we demonstrate...Single trapped ion 2.0(2)×10−5 Reference [6] (2009) Nuclear magnetic resonance 1.3(1)×10−4 Reference [7] (2010) Atoms in an optical lattice 1.4(1)×10...determined by comparing the qubit frequency measured in a Ramsey experiment with that of a Rabi experiment. Such back-to-back comparisons yielded values

  6. Machining with micro-size single crystalline diamond tools fabricated by a focused ion beam

    International Nuclear Information System (INIS)

    Ding, X; Butler, D L; Lim, G C; Shaw, K C; Liu, K; Fong, W S; Zheng, H Y; Cheng, C K

    2009-01-01

    A study was carried out to understand the physics of micro-scale mechanical machining (henceforth referred to as 'micro-machining') with a micro-size tool using a five-axis ultra-precision machine. A micro-size single crystalline diamond (SCD) tool with sharp cutting edges fabricated by a focused ion beam (FIB) was employed to orthogonal-machine four materials (three polycrystalline metals with various grain sizes and one amorphous metal plating material). Since the wealth of knowledge of macro-machining cannot be successfully used in micro-machining, this study contributes to the understanding of the physics of mechanical machining with micro-size tools

  7. Rational Design of Lanthanoid Single-Ion Magnets: Predictive Power of the Theoretical Models.

    Science.gov (United States)

    Baldoví, José J; Duan, Yan; Morales, Roser; Gaita-Ariño, Alejandro; Ruiz, Eliseo; Coronado, Eugenio

    2016-09-12

    We report two new single-ion magnets (SIMs) of a family of oxydiacetate lanthanide complexes with D3 symmetry to test the predictive capabilities of complete active space ab initio methods (CASSCF and CASPT2) and the semiempirical radial effective charge (REC) model. Comparison of the theoretical predictions of the energy levels, wave functions and magnetic properties with detailed spectroscopic and magnetic characterisation is used to critically discuss the limitations of these theoretical approaches. The need for spectroscopic information for a reliable description of the properties of lanthanide SIMs is emphasised. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Subattoampere current induced by single ions in silicon oxide layers of nonvolatile memory cells

    International Nuclear Information System (INIS)

    Cellere, G.; Paccagnella, A.; Larcher, L.; Visconti, A.; Bonanomi, M.

    2006-01-01

    A single ion impinging on a thin silicon dioxide layer generates a number of electron/hole pairs proportional to its linear energy transfer coefficient. Defects generated by recombination can act as a conductive path for electrons that cross the oxide barrier, thanks to a multitrap-assisted mechanism. We present data on the dependence of this phenomenon on the oxide thickness by using floating gate memory arrays. The tiny number of excess electrons stored in these devices allows for extremely high sensitivity, impossible with any direct measurement of oxide leakage current. Results are of particular interest for next generation devices

  9. Fracture analysis of surface exfoliation on single crystal silicon irradiated by intense pulsed ion beam

    Science.gov (United States)

    Shen, Jie; Shahid, Ijaz; Yu, Xiao; Zhang, Jie; Zhong, Haowen; Cui, Xiaojun; Liang, Guoying; Yu, Xiang; Huang, Wanying; Yan, Sha; Zhang, Gaolong; Zhang, Xiaofu; Le, Xiaoyun

    2017-12-01

    Surface exfoliation was observed on single crystal silicon surface irradiated by Intense Pulsed Ion Beam (IPIB). As the strong transient thermal stress impact induced by IPIB was mainly attributed to the exfoliation, a micro scale model combined with thermal conduction and linear elastic fracture mechanics was built to analyze the thermal stress distribution along the energy deposition process. After computation with finite element method, J integral parameter was applied as the criterion for crack development. It was demonstrated that the exfoliation initiation calls for specific material, crack depth and IPIB parameter. The results are potentially valuable for beam/target selection and IPIB parameter optimization.

  10. Monitoring volatilization products using Residual Gas Analyzers during MeV ion beam irradiations

    Science.gov (United States)

    Wetteland, C. J.; Kriewaldt, K.; Taylor, L. A.; McSween, H. Y.; Sickafus, K. E.

    2018-03-01

    The use of Residual Gas Analyzers (RGAs) during irradiation experiments can provide valuable information when incorporated into experimental end-stations. The instruments can track the volatilization products of beam-sensitive materials, which may ultimately aid researchers in selecting appropriate flux values for conducting experiments. Furthermore, the type of gaseous species released during an irradiation can be monitored directly, which may lead to new insights into the radiolysis and/or heating mechanisms responsible for gas evolution. A survey of several classes of materials exposed to extremes in particle flux is presented to show how RGA instrumentation can be incorporated to qualitatively assess ion-solid interactions in a variety of fields.

  11. Ion-chamber-based loss monitor system for the Los Alamos Meson Physics Facility

    International Nuclear Information System (INIS)

    Plum, M.A.; Brown, D.; Browman, A.; Macek, R.J.

    1995-01-01

    A new loss monitor system has been designed and installed at the Los Alamos Meson Physics Facility (LAMPF). The detectors are ion chambers filled with N 2 gas. The electronics modules have a threshold range of 1:100, and they can resolve changes in beam loss of about 2% of the threshold settings. They can generate a trip signal in 2 μs if the beam loss is large enough; if the response time of the Fast Protect System is included the beam will be shut off in about 37 μs

  12. Electron paramagnetic resonance and optical absorption of uranium ions diluted in CdF2 single crystals

    International Nuclear Information System (INIS)

    Pereira, J.J.C.R.

    1976-08-01

    The electron paramagnetic resonance (EPR) has been studied in conection with the optical absortion spectra of Uranium ions diluted in CdF 2 single crystals. Analyses of the EPR and optical absorption spectra obtained experimentally, and a comparison with known results in the isomorfic CaF 2 , SrF 2 and BaF 2 , allowed the identification of two paramagnetic centers associated with Uranium ions. These are the U(2+) ion in cubic symmetry having the triplet γ 5 as ground state, and the U(3+) ion in cubic symmetry having the dublet γ 6 as ground state. (Author) [pt

  13. Numerical Simulations of Calcium Ions Spiral Wave in Single Cardiac Myocyte

    Science.gov (United States)

    Bai, Yong-Qiang; Zhu, Xing

    2010-04-01

    The calcium ions (Ca2+) spark is an elementary Ca2+ release event in cardiac myocytes. It is believed to buildup cell-wide Ca2+ signals, such as Ca2+ transient and Ca2+ wave, through a Ca2+-induced Ca2+ release (CICR) mechanism. Here the excitability of the Ca2+ wave in a single cardiac myocyte is simulated by employing the fire-diffuse-fire model. By modulating the dynamic parameters of Ca2+ release and re-uptake channels, we find three Ca2+ signaling states in a single cardiac myocyte: no wave, plane wave, and spiral wave. The period of a spiral wave is variable in the different regimes. This study indicates that the spiral wave or the excitability of the system can be controlled through micro-modulation in a living excitable medium.

  14. Experimental Verification of a Jarzynski-Related Information-Theoretic Equality by a Single Trapped Ion

    Science.gov (United States)

    Xiong, T. P.; Yan, L. L.; Zhou, F.; Rehan, K.; Liang, D. F.; Chen, L.; Yang, W. L.; Ma, Z. H.; Feng, M.; Vedral, V.

    2018-01-01

    Most nonequilibrium processes in thermodynamics are quantified only by inequalities; however, the Jarzynski relation presents a remarkably simple and general equality relating nonequilibrium quantities with the equilibrium free energy, and this equality holds in both the classical and quantum regimes. We report a single-spin test and confirmation of the Jarzynski relation in the quantum regime using a single ultracold Ca40 + ion trapped in a harmonic potential, based on a general information-theoretic equality for a temporal evolution of the system sandwiched between two projective measurements. By considering both initially pure and mixed states, respectively, we verify, in an exact and fundamental fashion, the nonequilibrium quantum thermodynamics relevant to the mutual information and Jarzynski equality.

  15. High-fidelity state detection and tomography of a single-ion Zeeman qubit

    International Nuclear Information System (INIS)

    Keselman, A; Glickman, Y; Akerman, N; Kotler, S; Ozeri, R

    2011-01-01

    We demonstrate high-fidelity Zeeman qubit state detection in a single trapped 88 Sr + ion. Qubit readout is performed by shelving one of the qubit states to a metastable level using a narrow linewidth diode laser at 674 nm, followed by state-selective fluorescence detection. The average fidelity reached for the readout of the qubit state is 0.9989(1). We then measure the fidelity of state tomography, averaged over all possible single-qubit states, which is 0.9979(2). We also fully characterize the detection process using quantum process tomography. This readout fidelity is compatible with recent estimates of the detection error threshold required for fault-tolerant computation, whereas high-fidelity state tomography opens the way for high-precision quantum process tomography.

  16. High-fidelity state detection and tomography of a single-ion Zeeman qubit

    Energy Technology Data Exchange (ETDEWEB)

    Keselman, A; Glickman, Y; Akerman, N; Kotler, S; Ozeri, R, E-mail: ozeri@weizmann.ac.il [Physics of Complex Systems, Weizmann Institute of Science, Rehovot 76100 (Israel)

    2011-07-15

    We demonstrate high-fidelity Zeeman qubit state detection in a single trapped {sup 88}Sr{sup +} ion. Qubit readout is performed by shelving one of the qubit states to a metastable level using a narrow linewidth diode laser at 674 nm, followed by state-selective fluorescence detection. The average fidelity reached for the readout of the qubit state is 0.9989(1). We then measure the fidelity of state tomography, averaged over all possible single-qubit states, which is 0.9979(2). We also fully characterize the detection process using quantum process tomography. This readout fidelity is compatible with recent estimates of the detection error threshold required for fault-tolerant computation, whereas high-fidelity state tomography opens the way for high-precision quantum process tomography.

  17. Comparisons between direct ion storage and thermoluminescence dosimetry individual monitoring systems, and internet reporting

    International Nuclear Information System (INIS)

    Kiuru, A.; Kahilainen, J.; Hyvoenen, H.; Vartiainen, E.

    2001-01-01

    A new electronic direct ion storage (DIS) dosemeter allows accumulated personal dose equivalent H p (d) at depths of 10 mm and 0.07 mm to be monitored in a few seconds by inserting the dosemeter into a local reader without deleting the accumulated dose. The DIS system meets general requirements on individual monitoring of hospital personnel using ionising radiation. It differs greatly from off-line thermoluminescence dosimetry systems and offers many additional benefits. The non-volatile reading takes only 5 s, is taken as often as needed, and the data are collected into a dose database, where background radiation is subtracted. Individual personnel doses are reported in Intranet as well as on the Internet at regular intervals to the National Regulatory Authorities. (author)

  18. Exploration of ion temperature profile measurements at JET using the upgraded neutron profile monitor

    International Nuclear Information System (INIS)

    Marocco, D.; Esposito, B.; Riva, M.

    2012-01-01

    The neutron profile monitor (NPM), routinely used at the Joint European Torus for neutron emissivity profile measurements, consists of two fan-shaped arrays of collimators and each line of sight (LOS) is equipped with a NE213 liquid organic scintillator for simultaneous measurements of the 2.5 MeV and 14 MeV neutrons. A digital system developed in ENEA has replaced the analog acquisition electronics and now enables the NPM to perform spatially resolved neutron spectrometry by providing neutron pulse height spectra (PHS) for each LOS. However, the NPM was not originally designed as a spectrometer and, therefore, lacks several key features, such as detailed measurements of the detector response functions and the presence of detector stability monitors. We present a proof of principle of ion temperature profile measurements derived from the NPM PHS in high plasma current discharges using simulated detector response functions.

  19. Conductometric determination of single pores in polyethyleneterephthalate irradiated by heavy ions

    International Nuclear Information System (INIS)

    Oganesyan, V.R.; Trofimov, V.V.; Doerschel, B.; Hermsdorf, D.; Vetter, J.; Danziger, M.

    2002-01-01

    Most of the previous works devoted to the problem of track formation processes did not pay enough attention to direct measurement of the appearance of every individual pore in an array of many pores induced by the irradiation of polymer films with ions. Such measurements are not easy to carry out due to the extremely high electric resistance in the moment of pore opening. In this work the analysis of films irradiated with low particle fluences up to 3.7·10 3 ions/cm 2 is described. Polyethyleneterephthalate (PET) Hostaphan with a thickness of 20μm was used. The samples were irradiated with Bi ions of 11.4 MeV/amu energy. Using optimized etching conditions and computer aided data evaluation, we obtained results, which are in good agreement with theoretical predictions and model calculations. The measured increase of conductivity beginning from the breakthrough of a single track up to the next pore opening in dependence on the etching time and the number of opened pores confirm the assumed model. Thus, the developed 'track-by-track' method can be used effectively for description of the sequential appearance of individual pores in an electrolytic etching process

  20. Nanomechanical investigation of ion implanted single crystals - Challenges, possibilities and pitfall traps related to nanoindentation

    Science.gov (United States)

    Kurpaska, Lukasz

    2017-10-01

    Nanoindentation technique have developed considerably over last thirty years. Nowadays, commercially available systems offer very precise measurement in nano- and microscale, environmental noise cancelling (or at least noise suppressing), in situ high temperature indentation in controlled atmosphere and vacuum conditions and different additional options, among them dedicated indentation is one of the most popular. Due to its high precision, and ability to measure mechanical properties from very small depths (tens of nm), this technique become quite popular in the nuclear society. It is known that ion implantation (to some extent) can simulate the influence of neutron flux. However, depth of the material damage is very limited resulting in creation of thin layer of modified material over unmodified bulk. Therefore, only very precise technique, offering possibility to control depth of the measurement can be used to study functional properties of the material. For this reason, nanoindentation technique seems to be a perfect tool to investigate mechanical properties of ion implanted specimens. However, conducting correct nanomechanical experiment and extracting valuable mechanical parameters is not an easy task. In this paper a discussion about the nanoindentation tests performed on ion irradiated YSZ single crystal is presented. The goal of this paper is to discuss possible traps when studying mechanical properties of such materials and thin coatings.

  1. An investigation of electron paramagnetic resonance spectra of Mn+2 ion in silver nitrate single crystals

    International Nuclear Information System (INIS)

    Korkmaz, M.

    1974-01-01

    X-band EPR spectra of Mn +2 ion in AgNO 3 single crystals have been investigated as a function of temperature. Because of the small size of the fine structure constant 'a' and the large size of the hyperfine constant 'A' in this crystal, all electronic transitions are superimposed. For this reason, spectra consist of a group of six hyperfine components. The spectra appeared to be isotropic, although the symmetry of the host lattice is orthoromibc. This shows that the local symmetry of the paramagnetic ions is of cubic type. EPR signal disappears completely at -40 0 C. As the temperature is increased from this value the signal intensity increases steadily and reaches a maximum value at +40 0 C. If the temperature is raised further the signal tends to decrease. In other words in this crystal Mn +2 ion shows antiferromagnetic property below +40 0 C and paramagnetic property above +40 0 C. We also found that, in the antiferromagnetic region, the line width increases as the temperature is decreased. In the paramagnetic region the line width increases as the temperature is increased. Other spectral parameters A and g do not change with the temperature. Spectra obtained at room temperature and at different temperatures are also discussed. (Korkmaz, M.)

  2. Diode-like single-ion track membrane prepared by electro-stopping

    International Nuclear Information System (INIS)

    Apel, P.Yu.; Korchev, Yu.E.; Siwy, Z.; Spohr, R.; Yoshida, M.

    2001-01-01

    The preparation of an asymmetric membrane in poly(ethylene terephthalate) (PET) is described, using a combination of chemical and electro-stopping. For this purpose, a single-ion-irradiated PET film is inserted into an electrolytic cell and etched from one side in 9 M sodium hydroxide while bathing the other side in a mixture of 2 M KCl and 2 M HCOOH (1:1 by volume), electrically retracting the OH - ions from the tip of the etch pit during pore break-through. When a preset current has been reached, the etch process is interrupted by replacing the etching solution with acidic 1 M potassium chloride solution. After etching, the current-voltage (I-V) characteristic is determined under symmetric bathing conditions, immersing both sides of the membrane in KCl solutions of identical concentration (0.01-1 M) and pH (3-8). The I-V characteristic is strongly non-linear, comparable to that of an electrical diode. If the polarity during etching is reversed, pushing the OH - ions into the tip of the etch pit, the resulting pores are larger and the degree of asymmetry smaller. The importance of electro-stopping is compared with chemical stopping

  3. Conductometric determination of single pores in polyethyleneterephthalate irradiated by heavy ions

    CERN Document Server

    Oganesyan, V R; Dörschel, B; Hermsdorf, D; Trofimov, V V; Vetter, J

    2002-01-01

    Most of the previous works devoted to the problem of track formation processes did not pay enough attention to direct measurement of the appearance of every individual pore in an array of many pores induced by the irradiation of polymer films with ions. Such measurements are not easy to carry out due to the extremely high electric resistance in the moment of pore opening. In this work the analysis of films irradiated with low particle fluences up to 3.7 centre dot 10 sup 3 ions/cm sup 2 is described. Polyethyleneterephthalate (PET) Hostaphan with a thickness of 20 mu m was used. The samples were irradiated with Bi ions of 11.4 MeV/amu energy. Using optimized etching conditions and computer aided data evaluation, we obtained results, which are in good agreement with theoretical predictions and model calculations. The measured increase of conductivity beginning from the breakthrough of a single track up to the next pore opening in dependence on the etching time and the number of opened pores confirm the assumed...

  4. Conductometric Determination of Single Pores in Polyethyleneterephthalate Irradiated by Heavy Ions

    CERN Document Server

    Oganesyan, V R; Dörschel, B; Vetter, J E; Danziger, M; Hermsdorf, D

    2002-01-01

    Most of previous works devoted to the problem of track formation processes did not pay enough attention to direct measurement of the appearance of every individual pore in an array of many pores induced by the irradiation of polymer films with ions. Such measurements are not easy to carry out due to the extremely high electric resistance in the moment of pore opening. In this work the analysis of films irradiated with low particle fluences up to 3.7\\cdot 10^{3} ions/cm^2 is described. Polyethyleneterephthalate (PET) Hostaphan with a thickness of 20 m was used. The samples were irradiated with Bi ions of 11.4 MeV/amu energy. Using optimized etching conditions and computer aided data evaluation we obtained results, which are in good agreement with theoretical predictions and model calculations. The measured increase of conductivity beginning from the breakthrough of a single track up to the next pore opening in dependence on the etching time and the number of opened pores confirm the assumed model. Thus, the de...

  5. Development of the IFJ single ion hit facility for cells irradiation

    International Nuclear Information System (INIS)

    Veselov, O.; Polak, W.; Ugenskiene, R.; Hajduk, R.; Lebed, K.; Lekki, J.; Horwacik, T.; Dutkiewicz, E.M.; Maranda, S.; Pieprzyca, T.; Sarnecki, C.; Stachura, Z.; Szklarz, Z.; Styczen, J.

    2005-12-01

    In recent years a single ion hit facility (SIHF) has been constructed at the IFJ ion microprobe. The setup is used for the precise irradiations of living cells by a controlled number of ions. The facility allows investigations in various aspects of biomedical research, such as adaptive response, bystander effect, inverse dose-rate effect, low-dose hypersensitivity, etc. Those investigations have two very important requirements: (i) cells must be examined in their natural state and environment, i.e. without previously being killed, and preferentially, neither fixed nor stained, and (ii) a possibility of automatic irradiation of large number of cells with a computer recognition of their positions must be provided. This work presents some of the crucial features of the off-line and on-line optical systems, including self-developed software responsible for the automatic cell recognition. We also show several tests carried out to determine the efficiency of the whole setup and some segments. In conclusion, the results of our first irradiation measurements performed with living cells are demonstrated. (author)

  6. Designing Artificial Solid-Electrolyte Interphases for Single-Ion and High-Efficiency Transport in Batteries

    KAUST Repository

    Tu, Zhengyuan

    2017-09-21

    Substrates able to rectify transport of ions based on charge and/or size are ubiquitous in biological systems. Electrolytes and interphases that selectively transport electrochemically active ions are likewise of broad interest in all electrical energy storage technologies. In lithium-ion batteries, electrolytes with single- or near-single-ion conductivity reduce losses caused by ion polarization. In emergent lithium or sodium metal batteries, they maintain high conductivity at the anode and stabilize metal deposition by fundamental mechanisms. We report that 20- to 300-nm-thick, single-ion-conducting membranes deposited at the anode enable electrolytes with the highest combination of cation transference number, ionic conductivity, and electrochemical stability reported. By means of direct visualization we find that single-ion membranes also reduce dendritic deposition of Li in liquids. Galvanostatic measurements further show that the electrolytes facilitate long (3 mAh) recharge of full Li/LiNi0.8Co0.15Al0.05O2 (NCA) cells with high cathode loadings (3 mAh cm−2/19.9 mg cm−2) and at high current densities (3 mA cm−2).

  7. Quantitative Single-letter Sequencing: a method for simultaneously monitoring numerous known allelic variants in single DNA samples

    Directory of Open Access Journals (Sweden)

    Duborjal Hervé

    2008-02-01

    Full Text Available Abstract Background Pathogens such as fungi, bacteria and especially viruses, are highly variable even within an individual host, intensifying the difficulty of distinguishing and accurately quantifying numerous allelic variants co-existing in a single nucleic acid sample. The majority of currently available techniques are based on real-time PCR or primer extension and often require multiplexing adjustments that impose a practical limitation of the number of alleles that can be monitored simultaneously at a single locus. Results Here, we describe a novel method that allows the simultaneous quantification of numerous allelic variants in a single reaction tube and without multiplexing. Quantitative Single-letter Sequencing (QSS begins with a single PCR amplification step using a pair of primers flanking the polymorphic region of interest. Next, PCR products are submitted to single-letter sequencing with a fluorescently-labelled primer located upstream of the polymorphic region. The resulting monochromatic electropherogram shows numerous specific diagnostic peaks, attributable to specific variants, signifying their presence/absence in the DNA sample. Moreover, peak fluorescence can be quantified and used to estimate the frequency of the corresponding variant in the DNA population. Using engineered allelic markers in the genome of Cauliflower mosaic virus, we reliably monitored six different viral genotypes in DNA extracted from infected plants. Evaluation of the intrinsic variance of this method, as applied to both artificial plasmid DNA mixes and viral genome populations, demonstrates that QSS is a robust and reliable method of detection and quantification for variants with a relative frequency of between 0.05 and 1. Conclusion This simple method is easily transferable to many other biological systems and questions, including those involving high throughput analysis, and can be performed in any laboratory since it does not require specialized

  8. Persistent photoconductivity in hydrogen ion-implanted KNbO3 bulk single crystal

    Science.gov (United States)

    Tsuruoka, R.; Shinkawa, A.; Nishimura, T.; Tanuma, C.; Kuriyama, K.; Kushida, K.

    2017-06-01

    Persistent Photoconductivity (PPC) in hydorogen-ion implanted (001) oriented KNbO3 bulk single crystals (perovskite structure at room temperature; ferroelectric with a band gap of 3.16 eV) is studied in air at room temperature to prevent the crystallinity degradation caused by the phase transition. Hydrogen is implanted into KNbO3 bulk single crystals using the energy (the peak ion fluence) of 500 keV (5.0 × 1015 cm-2). The resistivity varies from ∼108 Ω/□ for an un-implanted KNbO3 sample to 2.3 × 105 Ω/□ for as-implanted one. suggesting the presence of donors consisting of hydrogen interstitial and oxygen vacancy. The PPC is clearly observed with ultraviolet and blue LEDs illumination rather than green and infrared, suggesting the release of electrons from the metastable conductive state below the conduction band relating to the charge states of the oxygen vacancy as observed in electron irradiated ZnO.

  9. Comb-shaped single ion conductors based on polyacrylate ethers and lithium alkyl sulfonate

    International Nuclear Information System (INIS)

    Sun Xiaoguang; Hou Jun; Kerr, John B.

    2005-01-01

    Comb-shaped single ion conductors have been synthesized by (1) sulfonation of small molecule chloroethyleneglycols, which, after ion exchange to the Li + salt were then converted to the acrylate by reaction with acryloyl chloride and copolymerized with polyethylene glycol monomethyl ether acrylate (Mn = 454, n = 8) (PAE 8 -co-E 3 SO 3 Li); (2) sulfonation of chloride end groups grafted on to prepolymers of polyacrylate ethers (PAE 8 -g-E n SO 3 Li, n = 2, 3). The highest conductivity at 25 deg. C of 2.0 x 10 -7 S cm -1 was obtained for the PAE 8 -co-E 3 SO 3 Li with a salt concentration of EO/Li = 40. The conductivity of PAE 8 -g-E 3 SO 3 Li is lower than that of PAE 8 -co-E 3 SO 3 Li at similar salt concentrations, which is related to the incomplete sulfonation of the grafted polymer that leads to a lower concentration of Li + . The addition of 50 wt.% of plasticizer, PC/EMC (1/1, v/v), to PAE 8 -g-E 2 SO 3 Li increases the ambient conductivity by three orders of magnitude, which is due to the increased ion mobility in a micro-liquid environment and an increase concentration of free ions as a result of the higher dielectric constant of the solvent. A symmetrical Li/Li cell with an electrolyte membrane consisting of 75 wt.% PC/EMC (1/1, v/v) was cycled at a current density of 100 μA cm -2 at 85 deg. C. The cycling profile showed no concentration polarization after a break-in period during the first few cycles, which was apparently due to reaction of the solvent at the lithium metal surface that reacted with lithium metal to form a stable SEI layer

  10. Ion assisted structural collapse of a single stranded DNA: A molecular dynamics approach

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, Soumadwip; Dixit, Himanshu; Chakrabarti, Rajarshi, E-mail: rajarshi@chem.iitb.ac.in

    2015-09-28

    Highlights: • The dynamics of a single-stranded DNA in presence of different concentrations of Mg{sup 2+} is investigated. • The initial DNA chain collapse is characterized by the formation of non-sequentially stacked base pairs. • The DNA chain re-swells at high concentrations of Mg{sup 2+} as a consequence of overcharging. - Abstract: The structure and dynamics of negatively charged nucleic acids strongly correlate with the concentration and charge of the oppositely charged counterions. It is well known that the structural collapse of DNA is favoured in the presence of additional salt, a source of excess oppositely charged ions. Under such conditions single stranded DNA adopts a collapsed coil like conformation, typically characterized by stacking base pairs. Using atomistic molecular dynamics simulation, we demonstrate that in the presence of additional divalent salt (MgCl{sub 2}) single stranded DNA with base sequence 5′-CGCGAATTCGCG-3′ (Dickerson Drew dodecamer) initially collapses and then expands with increasing salt concentration. This is due to the overcharging induced DNA chain swelling, a dominant factor at a higher divalent salt concentration. In a nutshell, our simulations show how in the presence of divalent salt, non-sequential base stacking and overcharging competes and affect single stranded DNA dynamics unlike a monovalent salt.

  11. Orthogonal Injection Ion Funnel Interface Providing Enhanced Performance for Selected Reaction Monitoring-Triple Quadrupole Mass Spectrometry.

    Science.gov (United States)

    Chen, Tsung-Chi; Fillmore, Thomas L; Prost, Spencer A; Moore, Ronald J; Ibrahim, Yehia M; Smith, Richard D

    2015-07-21

    The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher-pressure regions (e.g., ion source interfaces) of mass spectrometers, thus providing increased sensitivity. An "off-axis" ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to-charge ratios. In this study, a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadrupole mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at a pressure of 9-10 Torr. Key factors for the HPIF performance characterized included the effects of RF amplitude, the DC gradient, and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. The sensitivity enhancement in liquid chromatography selected reaction monitoring (LC-SRM) analyses of low-abundance peptides spiked into a highly complex mixture was also compared with that obtained using both a commercial S-lens interface and an in-line dual-ion funnel interface.

  12. Verifying Heisenberg's error-disturbance relation using a single trapped ion.

    Science.gov (United States)

    Zhou, Fei; Yan, Leilei; Gong, Shijie; Ma, Zhihao; He, Jiuzhou; Xiong, Taiping; Chen, Liang; Yang, Wanli; Feng, Mang; Vedral, Vlatko

    2016-10-01

    Heisenberg's uncertainty relations have played an essential role in quantum physics since its very beginning. The uncertainty relations in the modern quantum formalism have become a fundamental limitation on the joint measurements of general quantum mechanical observables, going much beyond the original discussion of the trade-off between knowing a particle's position and momentum. Recently, the uncertainty relations have generated a considerable amount of lively debate as a result of the new inequalities proposed as extensions of the original uncertainty relations. We report an experimental test of one of the new Heisenberg's uncertainty relations using a single 40 Ca + ion trapped in a harmonic potential. By performing unitary operations under carrier transitions, we verify the uncertainty relation proposed by Busch, Lahti, and Werner (BLW) based on a general error-trade-off relation for joint measurements on two compatible observables. The positive operator-valued measure, required by the compatible observables, is constructed by single-qubit operations, and the lower bound of the uncertainty, as observed, is satisfied in a state-independent manner. Our results provide the first evidence confirming the BLW-formulated uncertainty at a single-spin level and will stimulate broad interests in various fields associated with quantum mechanics.

  13. Verifying Heisenberg’s error-disturbance relation using a single trapped ion

    Science.gov (United States)

    Zhou, Fei; Yan, Leilei; Gong, Shijie; Ma, Zhihao; He, Jiuzhou; Xiong, Taiping; Chen, Liang; Yang, Wanli; Feng, Mang; Vedral, Vlatko

    2016-01-01

    Heisenberg’s uncertainty relations have played an essential role in quantum physics since its very beginning. The uncertainty relations in the modern quantum formalism have become a fundamental limitation on the joint measurements of general quantum mechanical observables, going much beyond the original discussion of the trade-off between knowing a particle’s position and momentum. Recently, the uncertainty relations have generated a considerable amount of lively debate as a result of the new inequalities proposed as extensions of the original uncertainty relations. We report an experimental test of one of the new Heisenberg’s uncertainty relations using a single 40Ca+ ion trapped in a harmonic potential. By performing unitary operations under carrier transitions, we verify the uncertainty relation proposed by Busch, Lahti, and Werner (BLW) based on a general error–trade-off relation for joint measurements on two compatible observables. The positive operator-valued measure, required by the compatible observables, is constructed by single-qubit operations, and the lower bound of the uncertainty, as observed, is satisfied in a state-independent manner. Our results provide the first evidence confirming the BLW-formulated uncertainty at a single-spin level and will stimulate broad interests in various fields associated with quantum mechanics. PMID:28861461

  14. How to resolve microsecond current fluctuations in single ion channels: The power of beta distributions

    Science.gov (United States)

    Schroeder, Indra

    2015-01-01

    Abstract A main ingredient for the understanding of structure/function correlates of ion channels is the quantitative description of single-channel gating and conductance. However, a wealth of information provided from fast current fluctuations beyond the temporal resolution of the recording system is often ignored, even though it is close to the time window accessible to molecular dynamics simulations. This kind of current fluctuations provide a special technical challenge, because individual opening/closing or blocking/unblocking events cannot be resolved, and the resulting averaging over undetected events decreases the single-channel current. Here, I briefly summarize the history of fast-current fluctuation analysis and focus on the so-called “beta distributions.” This tool exploits characteristics of current fluctuation-induced excess noise on the current amplitude histograms to reconstruct the true single-channel current and kinetic parameters. A guideline for the analysis and recent applications demonstrate that a construction of theoretical beta distributions by Markov Model simulations offers maximum flexibility as compared to analytical solutions. PMID:26368656

  15. Dependence of the structure of ion-modified NiTi single crystal layers on the orientation of irradiated surface

    Science.gov (United States)

    Poletika, T. M.; Meisner, L. L.; Girsova, S. L.; Tverdokhlebova, A. V.; Meisner, S. N.

    2017-07-01

    The composition and structure of Si layers implanted into titanium nickelide single crystals with different orientations relative to the ion beam propagation direction have been studied using Auger electron spectroscopy and transmission electron microscopy. The role of the "soft" [111]B2 and "hard" [001]B2 NiTi orientations in the formation of the structure of ion-modified surface layer, as well as the defect structure of the surface layers of the single crystals, has been revealed. Orientation effects of selective sputtering and channeling of ions, which control the composition and thickness of the oxide and amorphous layers being formed, ion and impurity penetration depth, as well as the concentration profile of the Ni distribution over the surface, have been detected.

  16. Routine β-Human Chorionic Gonadotropin Monitoring for Single-Dose Methotrexate Treatment in Ectopic Pregnancy.

    Science.gov (United States)

    Dai, Yuxin; Zhang, Guorui; Zhu, Lan; Lang, Jinghe; Liu, Zhufeng

    To evaluate an alternative monitoring protocol without day 4 β-human chorionic gonadotropin (β-hCG) measurement for predicting the need for a repeated methotrexate (MTX) dose in patients undergoing single-dose MTX therapy for ectopic pregnancy (EP). Single-center retrospective study (Canadian Task Force classification II-3). University-affiliated hospital. Included in the study were 184 EP patients treated with MTX between January 2009 and December 2016. Single-dose MTX treatment (50 mg/m 2 ). The patients were treated with repeated doses of MTX every 7 days, if necessary, according to Stovall's protocol, or with laparoscopic surgery in cases of tubal rupture. The success of a single-dose of MTX according to the alternative measure was defined as a >50% decrease in the β-hCG level between days 1 and 7 in clinically stable patients. The sensitivity, specificity, false-negative rate, false-positive rate, and attributable risk of this new monitoring measure were calculated and compared with the traditional regimen. The new protocol had a sensitivity and specificity of 100% and 88.7%, respectively, for predicting a required second dose in patients whose day 1 β-hCG levels were <2000 mIU/mL. For patients with day 1 β-hCG level ≥2000 mIU/mL, both monitoring regimens had the same efficiency. The new monitoring model without the day 4 β-hCG measurement may offer both patients and clinicians multiple options to monitor single-dose MTX therapy for selected EP patients, with a comparable clinical efficiency to Stovall's protocol and less expense and follow-up burden to patients. Copyright © 2017 American Association of Gynecologic Laparoscopists. Published by Elsevier Inc. All rights reserved.

  17. Coherent manipulation of three-qubit states in a molecular single-ion magnet

    Science.gov (United States)

    Jenkins, M. D.; Duan, Y.; Diosdado, B.; García-Ripoll, J. J.; Gaita-Ariño, A.; Giménez-Saiz, C.; Alonso, P. J.; Coronado, E.; Luis, F.

    2017-02-01

    We study the quantum spin dynamics of nearly isotropic Gd3 + ions entrapped in polyoxometalate molecules and diluted in crystals of a diamagnetic Y3 + derivative. The full energy-level spectrum and the orientations of the magnetic anisotropy axes have been determined by means of continuous-wave electron paramagnetic resonance experiments, using X-band (9-10 GHz) cavities and on-chip superconducting waveguides and 1.5-GHz resonators. The results show that seven allowed transitions between the 2 S +1 spin states can be separately addressed. Spin coherence T2 and spin-lattice relaxation T1 rates have been measured for each of these transitions in properly oriented single crystals. The results suggest that quantum spin coherence is limited by residual dipolar interactions with neighbor electronic spins. Coherent Rabi oscillations have been observed for all transitions. The Rabi frequencies increase with microwave power and agree quantitatively with predictions based on the spin Hamiltonian of the molecular spin. We argue that the spin states of each Gd3 + ion can be mapped onto the states of three addressable qubits (or, alternatively, of a d =8 -level "qudit"), for which the seven allowed transitions form a universal set of operations. Within this scheme, one of the coherent oscillations observed experimentally provides an implementation of a controlled-controlled-NOT (or Toffoli) three-qubit gate.

  18. The effect of Cu{sup II} ions in L-asparagine single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Santana, Ricardo C., E-mail: santana@ufg.br; Gontijo, Henrique O.; Menezes, Arthur F.; Martins, José A.; Carvalho, Jesiel F., E-mail: carvalho@ufg.br

    2016-11-15

    We report the synthesis, crystal growth, and spectroscopic characterization of L-asparagine monohydrate (LAM) single crystals doped with CuII. The crystals were successfully grown by slow cooling from a supersaturated aqueous solution up to size of 16×12×2 mm{sup 3};the effect of copper impurities in the crystals morphology was discussed. Electron Paramagnetic Resonance (EPR) was used to calculate the g and hyperfine coupling (A) tensors of the CuII ions (g{sub 1}=2.044, g{sub 2}=2.105, g{sub 3}=2.383and A{sub 1}≈0, A{sub 2}=35, A{sub 3}=108 Gauss). The EPR spectra for certain orientations of the magnetic field suggest that CuII ions are coordinated to two {sup 14}N atoms. Correlating the EPR and optical absorption results, the crystal field and the Cu{sup II} orbital bond parameters were calculated. The results indicate that the paramagnetic center occupies interstitial rhombic distorted site and the ground orbital state for the unpaired electron is the d(x{sup 2}-y{sup 2}).

  19. Non-destructive single-pass low-noise detection of ions in a beamline

    Science.gov (United States)

    Schmidt, Stefan; Murböck, Tobias; Andelkovic, Zoran; Birkl, Gerhard; Nörtershäuser, Wilfried; Stahl, Stefan; Vogel, Manuel

    2015-11-01

    We have conceived, built, and operated a device for the non-destructive single-pass detection of charged particles in a beamline. The detector is based on the non-resonant pick-up and subsequent low-noise amplification of the image charges induced in a cylindrical electrode surrounding the particles' beam path. The first stage of the amplification electronics is designed to be operated from room temperature down to liquid helium temperature. The device represents a non-destructive charge counter as well as a sensitive timing circuit. We present the concept and design details of the device. We have characterized its performance and show measurements with low-energy highly charged ions (such as Ar13+) passing through one of the electrodes of a cylindrical Penning trap. This work demonstrates a novel approach of non-destructive, low noise detection of charged particles which is, depending on the bunch structure, suitable, e.g., for ion traps, low-energy beamlines or accelerator transfer sections.

  20. Luminescent single-ion magnets from Lanthanoid(III) complexes with monodentate ketone ligands

    Energy Technology Data Exchange (ETDEWEB)

    Kanetomo, Takuya; Ishida, Takayuki, E-mail: takayuki.ishida@uec.ac.jp [Department of Engineering Science, The University of Electro-Communications, Tokyo (Japan)

    2016-02-01

    We synthesized [Ln{sup III}(hfac){sub 3}(H{sub 2}O)(L)] (abbreviated as Ln-L; Ln = Gd, Tb, Eu; L = DTBK (di-t-butyl ketone), BP (benzophenone)), in which the carbonyl oxygen atom was coordinated to the Ln ion center, despite of such bulky substituents. Their crystal structures were determined by means of X-ray diffraction study. Gd-DTBK is completely isomorphous to the di-t-butyl nitroxide derivative and accordingly can be regarded as a model with the ligand spin masked. The ac magnetic susceptibility measurements on Tb-DTBK and -BP showed frequency dependence, characteristic of single-ion magnets. They also displayed photoluminescence in the solid state at room temperature. The quantum yields of the luminescence of Tb-DTBK and -BP (λ{sub ex} = 360 nm) were improved to 57 and 35%, respectively, from that of the starting material [TbI{sup III}(hfac){sub 3}(H{sub 2}O){sub 2}] (28% at λ{sub ex} = 370 nm). Similarly, the quantum yields for Eu-DTBK and -BP were 8 and 15%, respectively, with λ{sub ex} = 400 nm, while that of the starting material [EuI{sup III}(hfac){sub 3}(H{sub 2}O){sub 2}] was 4% at λ{sub ex}=400 nm.

  1. Luminescent single-ion magnets from Lanthanoid(III) complexes with monodentate ketone ligands

    Science.gov (United States)

    Kanetomo, Takuya; Ishida, Takayuki

    2016-02-01

    We synthesized [LnIII(hfac)3(H2O)(L)] (abbreviated as Ln-L; Ln = Gd, Tb, Eu; L = DTBK (di-t-butyl ketone), BP (benzophenone)), in which the carbonyl oxygen atom was coordinated to the Ln ion center, despite of such bulky substituents. Their crystal structures were determined by means of X-ray diffraction study. Gd-DTBK is completely isomorphous to the di-t-butyl nitroxide derivative and accordingly can be regarded as a model with the ligand spin masked. The ac magnetic susceptibility measurements on Tb-DTBK and -BP showed frequency dependence, characteristic of single-ion magnets. They also displayed photoluminescence in the solid state at room temperature. The quantum yields of the luminescence of Tb-DTBK and -BP (λex = 360 nm) were improved to 57 and 35%, respectively, from that of the starting material [TbIIII(hfac)3(H2O)2] (28% at λex = 370 nm). Similarly, the quantum yields for Eu-DTBK and -BP were 8 and 15%, respectively, with λex = 400 nm, while that of the starting material [EuIIII(hfac)3(H2O)2] was 4% at λex=400 nm.

  2. Single Ion transient-IBIC analyses of semiconductor devices using a cryogenic temperature stage

    International Nuclear Information System (INIS)

    Laird, J.S.; Bardos, R.; Legge, G.J.F.; Jagadish, C.

    1998-01-01

    A new Transient - IBIC data acquisition and analysis system at MARC is described. A discussion on the need for single ion control and temperature control is also given. The recorded signal is used as the trigger for beam pulsing. The new cryostatic temperature control stage is introduced. Data is presented on line profiles across the edge of a Au-Si junction collected over the temperature range of 25-300K using a developed C-V and I-V variable temperature stage incorporating a liquid helium cryostat. It demonstrates the potential improvements in spatial resolution in materials of long lifetime by mapping on timing windows around the prompt charge component in the charge transient

  3. A diode laser stabilization scheme for 40Ca+ single-ion spectroscopy

    Science.gov (United States)

    Rohde, F.; Almendros, M.; Schuck, C.; Huwer, J.; Hennrich, M.; Eschner, J.

    2010-06-01

    We present a scheme for stabilizing multiple lasers at wavelengths between 795 and 866 nm to the same atomic reference line. A reference laser at 852 nm is stabilized to the Cs D2 line using a Doppler-free frequency modulation technique. Through transfer cavities, four lasers are stabilized to the relevant atomic transitions in 40Ca+. The rms linewidth of a transfer-locked laser is measured to be 123 kHz over 200 ms with respect to an independent atomic reference, the Rb D1 line. This stability is confirmed by the comparison of an excitation spectrum of a single 40Ca+ ion to an eight-level Bloch equation model. The long-term stability with respect to the same reference is measured to be 130 kHz over a period of 2 h. The high degree of stability is demonstrated by the measured Allan deviation around 10-11 between 1 and 100 s.

  4. A diode laser stabilization scheme for 40Ca+ single-ion spectroscopy

    International Nuclear Information System (INIS)

    Rohde, F; Almendros, M; Schuck, C; Huwer, J; Hennrich, M; Eschner, J

    2010-01-01

    We present a scheme for stabilizing multiple lasers at wavelengths between 795 and 866 nm to the same atomic reference line. A reference laser at 852 nm is stabilized to the Cs D 2 line using a Doppler-free frequency modulation technique. Through transfer cavities, four lasers are stabilized to the relevant atomic transitions in 40 Ca + . The rms linewidth of a transfer-locked laser is measured to be 123 kHz over 200 ms with respect to an independent atomic reference, the Rb D 1 line. This stability is confirmed by the comparison of an excitation spectrum of a single 40 Ca + ion to an eight-level Bloch equation model. The long-term stability with respect to the same reference is measured to be 130 kHz over a period of 2 h. The high degree of stability is demonstrated by the measured Allan deviation around 10 -11 between 1 and 100 s.

  5. Single Ion transient-IBIC analyses of semiconductor devices using a cryogenic temperature stage

    Energy Technology Data Exchange (ETDEWEB)

    Laird, J.S.; Bardos, R.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Jagadish, C. [Australian National Univ., Canberra, ACT (Australia). School of Physics, Electronic Materials Engineering

    1998-06-01

    A new Transient - IBIC data acquisition and analysis system at MARC is described. A discussion on the need for single ion control and temperature control is also given. The recorded signal is used as the trigger for beam pulsing. The new cryostatic temperature control stage is introduced. Data is presented on line profiles across the edge of a Au-Si junction collected over the temperature range of 25-300K using a developed C-V and I-V variable temperature stage incorporating a liquid helium cryostat. It demonstrates the potential improvements in spatial resolution in materials of long lifetime by mapping on timing windows around the prompt charge component in the charge transient. 2 figs.

  6. Dynamics of a single ion in a perturbed Penning trap: Octupolar perturbation

    International Nuclear Information System (INIS)

    Lara, Martin; Salas, J. Pablo

    2004-01-01

    Imperfections in the design or implementation of Penning traps may give rise to electrostatic perturbations that introduce nonlinearities in the dynamics. In this paper we investigate, from the point of view of classical mechanics, the dynamics of a single ion trapped in a Penning trap perturbed by an octupolar perturbation. Because of the axial symmetry of the problem, the system has two degrees of freedom. Hence, this model is ideal to be managed by numerical techniques like continuation of families of periodic orbits and Poincare surfaces of section. We find that, through the variation of the two parameters controlling the dynamics, several periodic orbits emanate from two fundamental periodic orbits. This process produces important changes (bifurcations) in the phase space structure leading to chaotic behavior

  7. Focused ion beam milling of nanocavities in single colloidal particles and self-assembled opals

    International Nuclear Information System (INIS)

    Woldering, Leon A; Otter, A M; Husken, Bart H; Vos, Willem L

    2006-01-01

    We present a new method of realizing single nanocavities in individual colloidal particles on the surface of silicon dioxide artificial opals using a focused ion beam milling technique. We show that both the radius and the position of the nanocavity can be controlled with nanometre precision, to radii as small as 40 nm. The relation between the defect size and the milling time has been established. We confirmed that milling not only occurs on the surface of the spheres, but into and through them as well. We also show that an array of nanocavities can be fashioned. Structurally modified colloids have interesting potential applications in nanolithography, as well as in chemical sensing and solar cells, and as photonic crystal cavities

  8. Angle-resolved imaging of single-crystal materials with MeV helium ions

    International Nuclear Information System (INIS)

    Strathman, M.D.; Baumann, S.

    1992-01-01

    The simplest form of angle-resolved mapping for single-crystal materials is the creation of a channeling angular scan. Several laboratories have expanded this simple procedure to include mapping as a function of two independent tilts. These angle-resolved images are particularly suited to the assessment of crystal parameters including disorder, lattice location of impurities, and lattice stress. This paper will describe the use of the Charles Evans and Associates RBS-400 scattering chamber for acquisition, display, and analysis of angle-resolved images obtained from backscattered helium ions. Typical data acquisition times are 20 min for a ±2deg X-Y tilt scan with 2500 pixels (8/100deg resolution), and 10 nC per pixel. In addition, we will present a method for automatically aligning crystals for channeling measurements based on this imaging technology. (orig.)

  9. On the calculation of single ion activity coefficients in homogeneous ionic systems by application of the grand canonical ensemble

    DEFF Research Database (Denmark)

    Sloth, Peter

    1993-01-01

    The grand canonical ensemble has been used to study the evaluation of single ion activity coefficients in homogeneous ionic fluids. In this work, the Coulombic interactions are truncated according to the minimum image approximation, and the ions are assumed to be placed in a structureless...... of the individual ionic activity coefficients with respect to the total ionic concentration. This formula has previously been proposed on the basis of somewhat different considerations....

  10. Ionization in matrix-assisted laser desorption/ionization: singly charged molecular ions are the lucky survivors.

    Science.gov (United States)

    Karas, M; Glückmann, M; Schäfer, J

    2000-01-01

    A new model for the ionization processes in UV matrix-assisted laser desorption/ionization (MALDI) which accounts for the major phenomena observed is presented and discussed. The model retains elements of earlier approaches, such as photoionization and photochemical reactions, but it redefines these in the light of new working questions, most importantly why only singly charged ions are detected. Based on experimental evidence, the formation of singly and multiply charged clusters by a deficiency/excess of ions and also by photoionization and subsequent photochemical processes is pointed out to be the major ionization processes, which typically occur in parallel. The generation of electrons and their partial loss into the surrounding vacuum and solid, on the one hand, results in a positively charged ion-neutral plume facilitating a high overall ionization yield. On the other hand, these electrons, and also the large excess of protonated matrix ions in the negative ion mode, induce effective ion reneutralization in the plume. These neutralization processes are most effective for the highly charged cluster ions initially formed. Their fragmentation behaviour is evidenced in fast metastable fragmentation characteristics and agrees well with an electron capture dissociation mechanism and the enthalpy transfer upon neutralization forms the rationale for the prominent fragmentation and intense chemical noise accompanying successful MALDI. Within the course of the paper, cross-correlations with other desorption/ionization techniques and with earlier discussions on their mechanisms are drawn. Copyright 2000 John Wiley & Sons, Ltd.

  11. Spectroscopy of single Pr3+ ion in LaF3 crystal at 1.5 K.

    Science.gov (United States)

    Nakamura, Ippei; Yoshihiro, Tatsuya; Inagawa, Hironori; Fujiyoshi, Satoru; Matsushita, Michio

    2014-12-08

    Optical read-out and manipulation of the nuclear spin state of single rare-earth ions doped in a crystal enable the large-scale storage and the transport of quantum information. Here, we report the photo-luminescence excitation spectroscopy results of single Pr(3+) ions in a bulk crystal of LaF3 at 1.5 K. In a bulk sample, the signal from a single ion at the focus is often hidden under the background signal originating from numerous out-of-focus ions in the entire sample. To combine with a homemade cryogenic confocal microscope, we developed a reflecting objective that works in superfluid helium with a numerical aperture of 0.99, which increases the signal by increasing the solid angle of collection to 1.16π and reduces the background by decreasing the focal volume. The photo-luminescence excitation spectrum of single Pr(3+) was measured at a wing of the spectral line of the (3)H4 → (3)P0 transition at 627.33 THz (477.89 nm). The spectrum of individual Pr(3+) ions appears on top of the background of 60 cps as isolated peaks with intensities of 20-30 cps and full-width at half-maximum widths of approximately 3 MHz at an excitation intensity of 80 W cm(-2).

  12. Internal and External Temperature Monitoring of a Li-Ion Battery with Fiber Bragg Grating Sensors

    Directory of Open Access Journals (Sweden)

    Susana Novais

    2016-08-01

    Full Text Available The integration of fiber Bragg grating (FBG sensors in lithium-ion cells for in-situ and in-operando temperature monitoring is presented herein. The measuring of internal and external temperature variations was performed through four FBG sensors during galvanostatic cycling at C-rates ranging from 1C to 8C. The FBG sensors were placed both outside and inside the cell, located in the center of the electrochemically active area and at the tab-electrode connection. The internal sensors recorded temperature variations of 4.0 ± 0.1 °C at 5C and 4.7 ± 0.1 °C at 8C at the center of the active area, and 3.9 ± 0.1 °C at 5C and 4.0 ± 0.1 °C at 8C at the tab-electrode connection, respectively. This study is intended to contribute to detection of a temperature gradient in real time inside a cell, which can determine possible damage in the battery performance when it operates under normal and abnormal operating conditions, as well as to demonstrate the technical feasibility of the integration of in-operando microsensors inside Li-ion cells.

  13. Operational experience of water quality improvement accompanied by monitoring with on-line ion chromatograph

    International Nuclear Information System (INIS)

    Kobayashi, M.; Maeda, K.; Hashimoto, H.; Ishibe, T.; Usui, N.; Osumi, K.; Ishigure, K.

    1997-01-01

    Hamaoka Unit No.1 (BWR 540 MWe) of Chubu Electric Power Company, Inc. had experienced fuel failures caused by fuel cladding corrosion at the cycle 11 in 1990. This cladding corrosion was considered to be caused by a combination of cladding material susceptibility to corrosion and anomalous reactor water quality. Based on the intensive investigations on the causes of anomalous reactor water quality, several countermeasures were proposed to improve the reactor water quality for the subsequent cycles operation. As the results of countermeasures, reactor water quality of Hamaoka Unit No.1 in the cycle 12 became much better than that of any other previous cycles and neither failure nor accelerated corrosion was found in the subsequent annual inspection. As one of the countermeasures for water quality improvement, an on-line ion chromatograph has been installed on Hamaoka Unit No.1 to reinforce reactor water quality monitoring, that has enabled us to identify ion species in reactor water and to evaluate reactor water behaviour in detail. (author). 3 refs, 8 figs, 2 tab

  14. Beam position monitor R&D for keV ion beams

    CERN Document Server

    Naveed, S; Nosych, A; Søby,L

    2013-01-01

    Beams of cooled antiprotons at keV energies shall be provided by the Ultra-low energy Storage Ring (USR) at the Facility for Low energy Antiproton and Ion Research (FLAIR) and the Extra Low ENergy Antiproton ring (ELENA) at CERN's Antiproton Decelerator (AD) facility. Both storage rings put challenging demands on the beam position monitoring (BPM) system as their capacitive pick-ups should be capable of determining the beam position of beams at low intensities and low velocities, close to the noise level of state-of-the-art electronics. In this contribution we describe the design and anticipated performance of BPMs for low-energy ion beams with a focus on the ELENA orbit measurement systems. We also present the particular challenges encountered in the numerical simulation of pickup response at very low beta values. Finally, we provide an outlook on how the implementation of faster algorithms for the simulation of BPM characteristics could potentially help speed up such studies considerably.

  15. Determination of perfluorobutane in rat blood by automatic headspace capillary gas chromatography and selected ion monitoring mass spectrometry.

    Science.gov (United States)

    Hvattum, E; Normann, P T; Oulie, I; Uran, S; Ringstad, O; Skotland, T

    2001-01-01

    A new contrast agent (Sonazoid; NC100100) for ultrasound imaging has been developed. It is an aqueous suspension of lipid stabilised perfluorobutane (PFB) gas microbubbles. An automatic headspace capillary gas-chromatographic mass spectrometric method using electron impact ionisation was developed for analysis of Sonazoid PFB in rat blood. The calibration standards were gaseous PFB dissolved in ethanol in the range of 0.5-5000 ng PFB. Fluorotrichloromethane (CFC 11) was used as an internal standard of the method and the MS detector was set to single ion monitoring of the base fragment ions of PFB (m/z 69 and 119) and CFC 11 (m/z 101). The calibration graph, made by plotting the peak area ratios of PFB (m/z 69) to CFC 11(m/z 101) against the amount of PFB, was fitted to a second-order polynomial equation with weighting 1/y2 and found to be reproducible. The limit of quantification of the method was set to 0.4 ng PFB. The between-day variation of the method was below 9.2% relative standard deviation (RSD) and the within-day variation of the method was below 7.6% RSD. The accuracy of the method, as compared to Coulter counter, was estimated by determination of PFB in samples where Sonazoid was added to saline and found to range from 91.5% to 105.2%. PFB, added as Sonazoid, was found to be stable for at least 7 months in rat blood samples when stored at -20 degrees C.

  16. Application about an one-single-channel online radioactive monitoring equipment used for multiple areas in Tianwan Nuclear Power Plant

    International Nuclear Information System (INIS)

    Li Zhong; Zheng Suhong; Hong Yuanjin

    2012-01-01

    Generally, one online monitoring instrument used for monitoring radioactive is needed for one area of nuclear island workshop in nuclear power plant. This paper will expound one monitoring system which can measure multiple areas by one instrument. It uses a single instrument, through the electromagnetic valve automatically switch and compressor continuous suction, realized the 11 different areas of on-line radioactive monitoring. Since its operation, this monitoring system is running stably, it is available for reference to fellows. (authors)

  17. Effect of giant plasmon excitations in single and double ionization of C60 in fast heavy-ion collisions

    Science.gov (United States)

    Kadhane, Umesh; Kelkar, A.; Misra, D.; Kumar, Ajay; Tribedi, Lokesh C.

    2007-04-01

    Single and multiple ionization of C60 in collisions with highly charged fast oxygen ions have been studied using the recoil-ion time-of-flight technique. The dependence of multiple-ionization cross sections on projectile charge state (qp) was found to be drastically different from those for an atomic target, such as Ne. A model based on the giant dipole plasmon resonance explains quite well the observed qp dependence for the single- and-double-ionization cross sections. But the same model deviates for triple and quadruple ionizations.

  18. Single-electron capture collisions of ground and metastable Ne2+ ions with molecular gases

    Science.gov (United States)

    Hasan, A.; Abu-Haija, O.; Harris, J.; Elkafrawy, T.; Kayani, A.; Kamber, E. Y.

    2013-09-01

    Using the translational energy-gain spectroscopy technique, we have measured the energy-gain spectra and absolute total cross sections for single-electron capture in collisions of Ne2+ with N2, CO2 and H2O at laboratory impact energies between 50 and 400 eV and 0° scattering angles. In all the collision systems studied here, reaction channels have been observed which indicate the presence of the long-lived metastable states of (2s2 2p4 1D and 1S) in the Ne2+ incident beam. These measurements also indicate that capture from the metastable states into excited states of the projectile product ions is the most important inelastic process. Contributions from capture accompanied by the excitation and ionization of the target product are also detected. In addition, the energy dependence of the total single-electron capture cross sections is studied and found to slowly increase with increasing impact energy. The present data are compared with the theoretical calculations of the classical over the barrier, extended classical over the barrier and Landau-Zener models.

  19. Detection of isolated protein-bound metal ions by single-particle cryo-STEM.

    Science.gov (United States)

    Elad, Nadav; Bellapadrona, Giuliano; Houben, Lothar; Sagi, Irit; Elbaum, Michael

    2017-10-17

    Metal ions play essential roles in many aspects of biological chemistry. Detecting their presence and location in proteins and cells is important for understanding biological function. Conventional structural methods such as X-ray crystallography and cryo-transmission electron microscopy can identify metal atoms on protein only if the protein structure is solved to atomic resolution. We demonstrate here the detection of isolated atoms of Zn and Fe on ferritin, using cryogenic annular dark-field scanning transmission electron microscopy (cryo-STEM) coupled with single-particle 3D reconstructions. Zn atoms are found in a pattern that matches precisely their location at the ferroxidase sites determined earlier by X-ray crystallography. By contrast, the Fe distribution is smeared along an arc corresponding to the proposed path from the ferroxidase sites to the mineral nucleation sites along the twofold axes. In this case the single-particle reconstruction is interpreted as a probability distribution function based on the average of individual locations. These results establish conditions for detection of isolated metal atoms in the broader context of electron cryo-microscopy and tomography.

  20. Optical spectroscopy of Eu3+ ions doped in KLu(WO4)2 single crystals

    International Nuclear Information System (INIS)

    Koubaa, T.; Dammak, M.; Pujol, M.C.; Aguiló, M.; Díaz, F.

    2015-01-01

    Europium single doped potassium lutetium tungstate Eu 3+ :KLu(WO 4 ) 2 single crystals have been grown with the top seeded solution growth slow cooling method. Their absorption spectra are studied in detail for principal light polarizations, E||N p , N m and N g at room and low temperatures. The absorption oscillator strengths parameters are calculated by means of the theory of f–f transition intensities for systems with anomalously strong configuration interaction and by Judd–Ofelt theory. The Ω t (t=2, 4, 6) intensity parameters, and the {O dk , O ck , Δ d , Δ c1 and Δ c2 } (k=1, 2, 3) ASCI parameters are calculated. The radiative transition rates A R , radiative lifetimes τ R , and fluorescent branching ratios β R associated with 5 D 0 – 7 F J transitions of Eu 3+ were determined. The calculated decay times are discussed and compared with experimental values. - Highlights: • Absorption spectra of Eu:KLuW are investigated with respect to principal light polarizations. • Spectroscopic properties of Eu:KLuW are modeled within conventional Judd–Ofelt and (ASCI) theories. • 5 D 0 multiplet shows the contribution of a NR processes and an ET between the Eu 3+ ions. • It is suggested that the Eu 3+ :KLuW is a potential host material for optical applications.

  1. A laser desorption-electron impact ionization ion trap mass spectrometer for real-time analysis of single atmospheric particles

    Science.gov (United States)

    Simpson, E. A.; Campuzano-Jost, P.; Hanna, S. J.; Robb, D. B.; Hepburn, J. H.; Blades, M. W.; Bertram, A. K.

    2009-04-01

    A novel aerosol ion trap mass spectrometer combining pulsed IR laser desorption with electron impact (EI) ionization for single particle studies is described. The strengths of this instrument include a two-step desorption and ionization process to minimize matrix effects; electron impact ionization, a universal and well-characterized ionization technique; vaporization and ionization inside the ion trap to improve sensitivity; and an ion trap mass spectrometer for MSn experiments. The instrument has been used for mass spectral identification of laboratory generated pure aerosols in the 600 nm-1.1 [mu]m geometric diameter range of a variety of aromatic and aliphatic compounds, as well as for tandem mass spectrometry studies (up to MS3) of single caffeine particles. We investigate the effect of various operational parameters on the mass spectrum and fragmentation patterns. The single particle detection limit of the instrument was found to be a 325 nm geometric diameter particle (8.7 × 107 molecules or 22 fg) for 2,4-dihydroxybenzoic acid. Lower single particle detection limits are predicted to be attainable by modifying the EI pulse. The use of laser desorption-electron impact (LD-EI) in an ion trap is a promising technique for determining the size and chemical composition of single aerosol particles in real time.

  2. Structural and optical properties of Cd{sup 2+} ion on the growth of sulphamic acid single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Rajyalakshmi, S.; Samatha, K. [Department of Physics, Andhra University, Visakhapatnam-530003 (India); Rao, Valluru Srinivasa; Reddy, P. V. S. S. S. N.; Rao, K. Ramachandra, E-mail: drkrcr@gmail.com [Crystal Growth & Nano Science Research Center, Department of Physics, Govt. College (A), Rajahmundry-533 105 (India); Krishna, V. Y. Rama [Department of Engg. Physics, Andhra University, Visakhapatnam-530003 (India)

    2016-05-06

    Transparent single crystals of Cadmium doped Sulphamic acid (SA) was grown by Conventional slow evaporation solution technique (SEST) which had the size of 13 × 8 × 7 mm{sup 3}. The grown single crystals have been characterized using single crystal X-ray diffraction UV-visible Spectral studies and Second harmonic generation (SHG) efficiency and the results were discussed. The lattice parameters of the grown Cd{sup 2+} ion doped SA crystal are confirmed by single crystal X-ray diffraction and belong to orthorhombic system. Optical transmittance of the crystal was recorded using UV-vis NIR spectrophotometer with its lower cut off wavelength around 259nm. SHG measurements indicate that the SHG efficiency of the grown Cd{sup 2+} ion doped SA crystal at a fundamental wavelength of 1064 nm is approximately equal to KDP.

  3. Catastrophic optical mirror damage in diode lasers monitored during single-pulse operation

    DEFF Research Database (Denmark)

    Zegler, M.; Tomm, J.W.; Reeber, D.

    2009-01-01

    Catastrophic optical mirror damage (COMD) is analyzed for 808 nm emitting diode lasers in single-pulse operation in order to separate facet degradation from subsequent degradation processes. During each pulse, nearfield and thermal images are monitored. A temporal resolution better than 7 µs...... is achieved. The thermal runaway process is unambiguously related to the occurrence of a “thermal flash.” A one-by-one correlation between nearfield, thermal flash, thermal runaway, and structural damage is observed. The single-pulse excitation technique allows for controlling the propagation...

  4. Synchrotron Topographic and Diffractometer Studies of Buried Layered Structures Obtained by Implantation with Swift Heavy Ions in Silicon Single Crystals

    International Nuclear Information System (INIS)

    Wierzchowski, W.; Wieteska, K.; Zymierska, D.; Graeff, W.; Czosnyka, T.; Choinski, J.

    2006-01-01

    A distribution of crystallographic defects and deformation in silicon crystals subjected to deep implantation (20-50 μm) with ions of the energy of a few MeV/amu is studied. Three different buried layered structures (single layer, binary buried structure and triple buried structure) were obtained by implantation of silicon single crystals with 184 MeV argon ions, 29.7 MeV boron ions, and 140 MeV argon ions, each implantation at a fluency of 1x10 14 ions cm -2 . The implanted samples were examined by means of white beam X-ray section and projection topography, monochromatic beam topography and by recording local rocking curves with the beam restricted to 50 x 50 μm 2 . The experiment pointed to a very low level of implantation-induced strain (below 10 -5 ). The white beam Bragg case section experiment revealed a layer producing district black contrast located at a depth of the expected mean ion range. The presence of these buried layered structures in studied silicon crystals strongly affected the fringe pattern caused by curvature of the samples. In case of white beam projection and monochromatic beam topographs the implanted areas were revealed as darker regions with a very tiny grain like structure. One may interpret these results as the effect of considerable heating causing annihilation of point defects and formation of dislocation loops connected with point defect clusters. (author)

  5. Irradiation of zinc single crystal with 500 keV singly-charged carbon ions: surface morphology, structure, hardness, and chemical modifications

    Science.gov (United States)

    Waqas Khaliq, M.; Butt, M. Z.; Saleem, Murtaza

    2017-07-01

    Cylindrical specimens of (1 0 4) oriented zinc single crystal (diameter  =  6 mm and length  =  5 mm) were irradiated with 500 keV C+1 ions with the help of a Pelletron accelerator. Six specimens were irradiated in an ultra-high vacuum (~10‒8 Torr) with different ion doses, namely 3.94  ×  1014, 3.24  ×  1015, 5.33  ×  1015, 7.52  ×  1015, 1.06  ×  1016, and 1.30  ×  1016 ions cm-2. A field emission scanning electron microscope (FESEM) was utilized for the morphological study of the irradiated specimens. Formation of nano- and sub-micron size rods, clusters, flower- and fork-like structures, etc, was observed. Surface roughness of the irradiated specimens showed an increasing trend with the ions dose. Energy dispersive x-ray spectroscopy (EDX) helped to determine chemical modifications in the specimens. It was found that carbon content varied in the range 22.86-31.20 wt.% and that oxygen content was almost constant, with an average value of 10.16 wt.%. The balance content was zinc. Structural parameters, i.e. crystallite size and lattice strain, were determined by Williamson-Hall analysis using x-ray diffraction (XRD) patterns of the irradiated specimens. Both crystallite size and lattice strain showed a decreasing trend with the increasing ions dose. A good linear relationship between crystallite size and lattice strain was observed. Surface hardness depicted a decreasing trend with the ions dose and followed an inverse Hall-Petch relation. FTIR spectra of the specimens revealed that absorption bands gradually diminish as the dose of singly-charged carbon ions is increased from 3.94  ×  1014 ions cm-1 to 1.30  ×  1016 ions cm-1. This indicates progressive deterioration of chemical bonds with the increase in ion dose.

  6. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Science.gov (United States)

    Prakrajang, K.; Jeynes, J. C. G.; Merchant, M. J.; Kirkby, K.; Kirkby, N.; Thopan, P.; Yu, L. D.

    2013-07-01

    As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  7. Selected ion monitoring analysis of pseudoracemic hexobarbital and its major metabolites in blood and urine of rats

    NARCIS (Netherlands)

    van der Graaff, M; Hofman, P H; Breimer, D D; Vermeulen, N P; Knabe, J; Schamber, L

    A stereospecific synthesis of N1-(2H3)-labelled R(-)-hexobarbital is described. A sensitive and rapid selected ion monitoring assay procedure for pseudoracemic hexobarbital, consisting of equal amounts of S(+)-hexobarbital (1a) and (2H3)-R(-)-hexobarbital (1b) in 100 microliters blood samples of

  8. Simulation study based on the single-point temperature monitoring system of LabVIEW

    Science.gov (United States)

    Wu, Yongling; Yang, Na; Liu, Shuping; Pan, Xiaohui; Wang, Wenjiang

    2014-12-01

    This paper takes LabVIEW2012 as a development platform, creating a J-type thermocouple sensor and the NI USB-6229 data acquisition card and other hardware emulation circuitry which combined with the PC designed a single-point temperature monitoring system. Through simulation experiments, the system has a collection interval, the sampling rate per channel sampling on the temperature limit set by the user function and it also has the function of real-time display the current temperature, the temperature limit alarm, maximum temperature, minimum temperature display and a temperature history data query. This system can be used for temperature monitoring of life, research, industrial control, environmental monitoring, biomedical, tobacco processing, greenhouse cultivation, livestock breeding and other fields, which has important significance and practical value.

  9. X-ray beam monitor made by thin-film CVD single-crystal diamond.

    Science.gov (United States)

    Marinelli, Marco; Milani, E; Prestopino, G; Verona, C; Verona-Rinati, G; Angelone, M; Pillon, M; Kachkanov, V; Tartoni, N; Benetti, M; Cannatà, D; Di Pietrantonio, F

    2012-11-01

    A novel beam position monitor, operated at zero bias voltage, based on high-quality chemical-vapor-deposition single-crystal Schottky diamond for use under intense synchrotron X-ray beams was fabricated and tested. The total thickness of the diamond thin-film beam monitor is about 60 µm. The diamond beam monitor was inserted in the B16 beamline of the Diamond Light Source synchrotron in Harwell (UK). The device was characterized under monochromatic high-flux X-ray beams from 6 to 20 keV and a micro-focused 10 keV beam with a spot size of approximately 2 µm × 3 µm square. Time response, linearity and position sensitivity were investigated. Device response uniformity was measured by a raster scan of the diamond surface with the micro-focused beam. Transmissivity and spectral responsivity versus beam energy were also measured, showing excellent performance of the new thin-film single-crystal diamond beam monitor.

  10. Realization of a scanning ion beam monitor; Realisation d'un dispositif de controle et d'imagerie de faisceaux balayes d'ions

    Energy Technology Data Exchange (ETDEWEB)

    Pautard, C

    2008-07-15

    During this thesis, a scanning ion beam monitor has been developed in order to measure on-line fluence spatial distributions. This monitor is composed of an ionization chamber, Hall Effect sensors and a scintillator. The ionization chamber set between the beam exit and the experiment measures the ion rate. The beam spot is localized thanks to the Hall Effect sensors set near the beam sweeping magnets. The scintillator is used with a photomultiplier tube to calibrate the ionization chamber and with an imaging device to calibrate the Hall Effect sensors. This monitor was developed to control the beam lines of a radiobiology dedicated experimentation room at GANIL. These experiments are held in the context of the research in hadron-therapy. As a matter of fact, this new cancer treatment technique is based on ion irradiations and therefore demands accurate knowledge about the relation between the dose deposit in biological samples and the induced effects. To be effective, these studies require an on-line control of the fluence. The monitor has been tested with different beams at GANIL. Fluence can be measured with a relative precision of {+-}4% for a dose rate ranging between 1 mGy/s and 2 Gy/s. Once permanently set on the beam lines dedicated to radiobiology at GANIL, this monitor will enable users to control the fluence spatial distribution for each irradiation. The scintillator and the imaging device are also used to control the position, the spot shape and the energy of different beams such as those used for hadron-therapy. (author)

  11. Water softening by single-bowl ion exchange filter efficiency estimate and improvement

    OpenAIRE

    Kostygin, V. A.; Stolyarenko, G. S.; Kochetov, G. M.; Tugay, A. M.; Vashchenko, V. N.

    2014-01-01

    The article presents results of experimental investigations of the water softener in a laboratory installation of uninterruptible countercurrent ion exchange filter, which has a movable layer of ion exchange material. The installation provides for two simultaneous processes: counter ion sorption and regeneration of the sorbent with the processing capability of the sorbent in the regeneration zone by ultrasonic radiation.

  12. Electrode property of single-walled carbon nanotubes in all-solid-state lithium ion battery using polymer electrolyte

    Energy Technology Data Exchange (ETDEWEB)

    Sakamoto, Y.; Ishii, Y.; Kawasaki, S., E-mail: kawasaki.shinji@nitech.ac.jp [Nagoya Institute of Technology, Gokiso, Showa, Nagoya, Aichi (Japan)

    2016-07-06

    Electrode properties of single-walled carbon nanotubes (SWCNTs) in an all-solid-state lithium ion battery were investigated using poly-ethylene oxide (PEO) solid electrolyte. Charge-discharge curves of SWCNTs in the solid electrolyte cell were successfully observed. It was found that PEO electrolyte decomposes on the surface of SWCNTs.

  13. Possible wave formation and martensitic transformation of iron particles in copper single crystals during argon ion bombardment

    DEFF Research Database (Denmark)

    Thölén, Anders Ragnar; Li, Chang-Hai; Easterling, K.E.

    1983-01-01

    Thin single crystal copper specimens (thickness ~250 nm) containing coherent iron particles (diameter 40–50 nm) have been bombarded with argon ions (5, 80, and 330 keV). During this process some of the iron particles transform to martensite. The transformation was observed near the exposed surface...

  14. MeV single-ion beam irradiation of mammalian cells using the Surrey vertical nanobeam, compared with broad proton beam and X-ray irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Prakrajang, K. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Faculty of Science, Maejo University, Chiang Mai 50290 (Thailand); Jeynes, J.C.G.; Merchant, M.J.; Kirkby, K.; Kirkby, N. [Surrey Ion Beam Center, Faculty of Engineering and Physical Science, University of Surrey, Guildford Surrey, GU2 7XH (United Kingdom); Thopan, P. [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Yu, L.D., E-mail: yuld@fnrf.science.cmu.ac.th [Plasma and Beam Physics Research Facility, Department of Physics and Materials Science, Faculty of Science, Chiang Mai University, Chiang Mai 50200 (Thailand); Thailand Center of Excellence in Physics, Commission on Higher Education, 328 Si Ayutthaya Road, Bangkok 10400 (Thailand)

    2013-07-15

    Highlights: •Recently completed nanobeam at the Surrey Ion Beam Centre was used. •3.8-MeV single and broad proton beams irradiated Chinese hamster cells. •Cell survival curves were measured and compared with 300-kV X-ray irradiation. •Single ion irradiation had a lower survival part at ultra-low dose. •It implies hypersensitivity, bystander effect and cell cycle phase of cell death. -- Abstract: As a part of a systematic study on mechanisms involved in physical cancer therapies, this work investigated response of mammalian cells to ultra-low-dose ion beam irradiation. The ion beam irradiation was performed using the recently completed nanobeam facility at the Surrey Ion Beam Centre. A scanning focused vertical ion nano-beam was applied to irradiate Chinese hamster V79 cells. The V79 cells were irradiated in two different beam modes, namely, focused single ion beam and defocused scanning broad ion beam of 3.8-MeV protons. The single ion beam was capable of irradiating a single cell with a precisely controlled number of the ions to extremely low doses. After irradiation and cell incubation, the number of surviving colonies as a function of the number of the irradiating ions was measured for the cell survival fraction curve. A lower survival for the single ion beam irradiation than that of the broad beam case implied the hypersensitivity and bystander effect. The ion-beam-induced cell survival curves were compared with that from 300-kV X-ray irradiation. Theoretical studies indicated that the cell death in single ion irradiation mainly occurred in the cell cycle phases of cell division and intervals between the cell division and the DNA replication. The success in the experiment demonstrated the Surrey vertical nanobeam successfully completed.

  15. Rational design of single-ion magnets and spin qubits based on mononuclear lanthanoid complexes.

    Science.gov (United States)

    Baldoví, José J; Cardona-Serra, Salvador; Clemente-Juan, Juan M; Coronado, Eugenio; Gaita-Ariño, Alejandro; Palii, Andrew

    2012-11-19

    Here we develop a general approach to calculating the energy spectrum and the wave functions of the low-lying magnetic levels of a lanthanoid ion submitted to the crystal field created by the surrounding ligands. This model allows us to propose general criteria for the rational design of new mononuclear lanthanoid complexes behaving as single-molecule magnets (SMMs) or acting as robust spin qubits. Three typical environments exhibited by these metal complexes are considered, namely, (a) square antiprism, (b) triangular dodecahedron, and (c) trigonal prism. The developed model is used to explain the properties of some representative examples showing these geometries. Key questions in this area, such as the chemical tailoring of the superparamagnetic energy barrier, tunneling gap, or spin relaxation time, are discussed. Finally, in order to take into account delocalization and/or covalent effects of the ligands, this point-charge model is complemented with ab initio calculations, which provide accurate information on the charge distribution around the metal, allowing for an explanation of the SMM behavior displayed by some sandwich-type organometallic compounds.

  16. A diode laser stabilization scheme for {sup 40}Ca{sup +} single-ion spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Rohde, F; Almendros, M; Schuck, C; Huwer, J; Hennrich, M; Eschner, J, E-mail: felix.rohde@icfo.e [ICFO-Institut de Ciencies Fotoniques, Mediterranean Technology Park, E-08860 Castelldefels, Barcelona (Spain)

    2010-06-14

    We present a scheme for stabilizing multiple lasers at wavelengths between 795 and 866 nm to the same atomic reference line. A reference laser at 852 nm is stabilized to the Cs D{sub 2} line using a Doppler-free frequency modulation technique. Through transfer cavities, four lasers are stabilized to the relevant atomic transitions in {sup 40}Ca{sup +}. The rms linewidth of a transfer-locked laser is measured to be 123 kHz over 200 ms with respect to an independent atomic reference, the Rb D{sub 1} line. This stability is confirmed by the comparison of an excitation spectrum of a single {sup 40}Ca{sup +} ion to an eight-level Bloch equation model. The long-term stability with respect to the same reference is measured to be 130 kHz over a period of 2 h. The high degree of stability is demonstrated by the measured Allan deviation around 10{sup -11} between 1 and 100 s.

  17. Core-satellites assembly of silver nanoparticles on a single gold nanoparticle via metal ion-mediated complex.

    Science.gov (United States)

    Choi, Inhee; Song, Hyeon Don; Lee, Suseung; Yang, Young In; Kang, Taewook; Yi, Jongheop

    2012-07-25

    We report core-satellites (Au-Ag) coupled plasmonic nanoassemblies based on bottom-up, high-density assembly of molecular-scale silver nanoparticles on a single gold nanoparticle surface, and demonstrate direct observation and quantification of enhanced plasmon coupling (i.e., intensity amplification and apparent spectra shift) in a single particle level. We also explore metal ion sensing capability based on our coupled plasmonic core-satellites, which enabled at least 1000 times better detection limit as compared to that of a single plasmonic nanoparticle. Our results demonstrate and suggest substantial promise for the development of coupled plasmonic nanostructures for ultrasensitive detection of various biological and chemical analytes.

  18. Single event effects induced by 15.14 MeV/u sup 1 sup 3 sup 6 Xe ions

    CERN Document Server

    Hou Ming Dong; LiuJie; Wang Zhi Guang; Jin Yun Fan; Zhu Zhi Yong; Zhen Hong Lou; Liu Chang Long; Chen Xiao Xi; Wei Xin Guo; Zhang Li; Fan You Cheng; Zhu Zhou Rong; Zhang Yiting

    2002-01-01

    Single event effects induced by 15.14 MeV/u sup 1 sup 3 sup 6 Xe ions in different batches of 32k x 8 bits static random access memory are studied. The incident angle dependences of the cross sections for single event upset and single event latch up are presented. The SEE cross sections are plotted versus energy loss instead of linear energy transfer value in sensitive region. The depth of sensitive volume and thickness of 'dead' layer above the sensitive volume are estimated

  19. Diagnostics and Degradation Investigations of Li-Ion Battery Electrodes using Single Nanowire Electrochemical Cells

    Science.gov (United States)

    Palapati, Naveen Kumar Reddy

    Portable energy storage devices, which drive advanced technological devices, are improving the productivity and quality of our everyday lives. In order to meet the growing needs for energy storage in transportation applications, the current lithium-ion (Li-ion) battery technology requires new electrode materials with performance improvements in multiple aspects: (1) energy and power densities, (2) safety, and (3) performance lifetime. While a number of interesting nanomaterials have been synthesized in recent years with promising performance, accurate capabilities to probe the intrinsic performance of these high-performance materials within a battery environment are lacking. Most studies on electrode nanomaterials have so far used traditional, bulk-scale techniques such as cyclic voltammetry, electrochemical impedance spectroscopy, and Raman spectroscopy. These approaches give an ensemble-average estimation of the electrochemical properties of a battery electrode and does not provide a true indication of the performance that is intrinsic to its material system. Thus, new techniques are essential to understand the changes happening at a single particle level during the operation of a battery. The results from this thesis solve this need and study the electrical, mechanical and size changes that take place in a battery electrode at a single particle level. Single nanowire lithium cells are built by depositing nanowires in carefully designed device regions of a silicon chip using Dielectrophoresis (DEP). This work has demonstrated the assembly of several NW cathode materials like LiFePO 4, pristine and acid-leached alpha-MnO2, todorokite - MnO2, acid and nonacid-leached Na0.44MnO2. Within these materials, alpha-MnO2 was chosen as the model material system for electrochemical experiments. Electrochemical lithiation of pristine alpha-MnO 2 was performed inside a glove box. The volume, elasticity and conductivity changes were measured at each state-of-charge (SOC) to

  20. Single-cell bioelectrical impedance platform for monitoring cellular response to drug treatment

    Science.gov (United States)

    Asphahani, Fareid; Wang, Kui; Thein, Myo; Veiseh, Omid; Yung, Sandy; Xu, Jian; Zhang, Miqin

    2011-02-01

    The response of cells to a chemical or biological agent in terms of their impedance changes in real-time is a useful mechanism that can be utilized for a wide variety of biomedical and environmental applications. The use of a single-cell-based analytical platform could be an effective approach to acquiring more sensitive cell impedance measurements, particularly in applications where only diminutive changes in impedance are expected. Here, we report the development of an on-chip cell impedance biosensor with two types of electrodes that host individual cells and cell populations, respectively, to study its efficacy in detecting cellular response. Human glioblastoma (U87MG) cells were patterned on single- and multi-cell electrodes through ligand-mediated natural cell adhesion. We comparatively investigated how these cancer cells on both types of electrodes respond to an ion channel inhibitor, chlorotoxin (CTX), in terms of their shape alternations and impedance changes to exploit the fine detectability of the single-cell-based system. The detecting electrodes hosting single cells exhibited a significant reduction in the real impedance signal, while electrodes hosting confluent monolayer of cells showed little to no impedance change. When single-cell electrodes were treated with CTX of different doses, a dose-dependent impedance change was observed. This enables us to identify the effective dose needed for this particular treatment. Our study demonstrated that this single-cell impedance system may potentially serve as a useful analytical tool for biomedical applications such as environmental toxin detection and drug evaluation.

  1. Novel single-cell mega-size chambers for electrochemical etching of panorama position-sensitive polycarbonate ion image detectors

    Science.gov (United States)

    Sohrabi, Mehdi

    2017-11-01

    A novel development is made here by inventing panorama single-cell mega-size electrochemical etching (MS-ECE) chamber systems for processing panorama position-sensitive mega-size polycarbonate ion image detectors (MS-PCIDs) of potential for many neutron and ion detection applications in particular hydrogen ions or proton tracks and images detected for the first time in polycarbonates in this study. The MS-PCID is simply a large polycarbonate sheet of a desired size. The single-cell MS-ECE invented consists of two large equally sized transparent Plexiglas sheets as chamber walls holding a MS-PCID and the ECE chamber components tightly together. One wall has a large flat stainless steel electrode (dry cell) attached to it which is directly in contact with the MS-PCID and the other wall has a rod electrode with two holes to facilitate feeding and draining out the etching solution from the wet cell. A silicon rubber washer plays the role of the wet cell to hold the etchant and the electrical insulator to isolate the dry cell from the wet cell. A simple 50 Hz-HV home-made generator provides an adequate field strength through the two electrodes across the MS-ECE chamber. Two panorama single-cell MS-ECE chamber systems (circular and rectangular shapes) constructed were efficiently applied to processing the MS-PCIDs for 4π ion emission image detection of different gases in particular hydrogen ions or protons in a 3.5 kJ plasma focus device (PFD as uniquely observed by the unaided eyes). The panorama MS-PCID/MS-ECE image detection systems invented are novel with high potential for many applications in particular as applied to 4π panorama ion emission angular distribution image detection studies in PFD space, some results of which are presented and discussed.

  2. Effect of H{sup +} ion implantation on structural, morphological, optical and dielectric properties of L-arginine monohydrochloride monohydrate single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Sangeetha, K. [Crystal Growth and Thin film Laboratory, Department of Physics, School of Physics, Bharathidasan University, Tiruchirappalli 620024, Tamil Nadu (India); Babu, R. Ramesh, E-mail: rampap2k@yahoo.co.in [Crystal Growth and Thin film Laboratory, Department of Physics, School of Physics, Bharathidasan University, Tiruchirappalli 620024, Tamil Nadu (India); Kumar, P. [Inter-University Accelerator Centre, P.O. Box 10502, Aruna Asaf Ali Marg, New Delhi 110067 (India); Bhagvannarayana, G. [Materials Characterization Division, National Physical Laboratory, New Delhi 110012 (India); Ramamurthi, K. [Crystal Growth and Thin film Laboratory, Department of Physics, School of Physics, Bharathidasan University, Tiruchirappalli 620024, Tamil Nadu (India)

    2011-06-15

    L-arginine monohydrochloride monohydrate (LAHCl) single crystals have been implanted with 100 keV H{sup +} ions at different ion fluence ranging from 10{sup 12} to 10{sup 15} ions/cm{sup 2}. Implanted LAHCl single crystals have been investigated for property changes. Crystal surface and crystalline perfection of the pristine and implanted crystals were analyzed by atomic force microscope and high-resolution X-ray diffraction studies, respectively. Optical absorption bands induced by colour centers, refractive index and birefringence, mechanical stability and dielectric constant of implanted crystals were studied at different ion fluence and compared with that of pristine LAHCl single crystal.

  3. Changes in ion channel geometry resolved to sub-ångström precision via single molecule mass spectrometry

    Science.gov (United States)

    Robertson, Joseph W. F.; Kasianowicz, John J.; Reiner, Joseph E.

    2010-11-01

    The ion channel formed by Staphylococcus aureus alpha-hemolysin switches between multiple open conducting states. We describe a method for precisely estimating the changes in the ion channel geometry that correspond to these different states. Experimentally, we observed that the permeability of a single channel to differently sized poly(ethylene glycol) molecules depends on the magnitude of the open state conductance. A simple theory is proposed for determining changes in channel length of 4.2% and in cross-sectional area of - 0.4%.

  4. Strong coupling between a single nitrogen-vacancy spin and the rotational mode of diamonds levitating in an ion trap

    Science.gov (United States)

    Delord, T.; Nicolas, L.; Chassagneux, Y.; Hétet, G.

    2017-12-01

    A scheme for strong coupling between a single atomic spin and the rotational mode of levitating nanoparticles is proposed. The idea is based on spin readout of nitrogen-vacancy centers embedded in aspherical nanodiamonds levitating in an ion trap. We show that the asymmetry of the diamond induces a rotational confinement in the ion trap. Using a weak homogeneous magnetic field and a strong microwave driving we then demonstrate that the spin of the nitrogen-vacancy center can be strongly coupled to the rotational mode of the diamond.

  5. Investigations of high mobility single crystal chemical vapor deposition diamond for radiotherapy photon beam monitoring

    Science.gov (United States)

    Tromson, D.; Descamps, C.; Tranchant, N.; Bergonzo, P.; Nesladek, M.; Isambert, A.

    2008-03-01

    The intrinsic properties of diamond make this material theoretically very suitable for applications in medical physics. Until now ionization chambers have been fabricated from natural stones and are commercialized by PTW, but their fairly high costs and long delivery times have often limited their use in hospital. The properties of commercialized intrinsic polycrystalline diamond were investigated in the past by many groups. The results were not completely satisfactory due to the nature of the polycrystalline material itself. In contrast, the recent progresses in the growth of high mobility single crystal synthetic diamonds prepared by chemical vapor deposition (CVD) technique offer new alternatives. In the framework of the MAESTRO project (Methods and Advanced Treatments and Simulations for Radio Oncology), the CEA-LIST is studying the potentialities of synthetic diamond for new techniques of irradiation such as intensity modulated radiation therapy. In this paper, we present the growth and characteristics of single crystal diamond prepared at CEA-LIST in the framework of the NoRHDia project (Novel Radiation Hard CVD Diamond Detector for Hadrons Physics), as well as the investigations of high mobility single crystal CVD diamond for radiotherapy photon beam monitoring: dosimetric analysis performed with the single crystal diamond detector in terms of stability and repeatability of the response signal, signal to noise ratio, response speed, linearity of the signal versus the absorbed dose, and dose rate. The measurements performed with photon beams using radiotherapy facilities demonstrate that single crystal CVD diamond is a good alternative for air ionization chambers for beam quality control.

  6. Single-lead portable ECG devices: Perceptions and clinical accuracy compared to conventional cardiac monitoring.

    Science.gov (United States)

    Mehta, Devin D; Nazir, Noreen T; Trohman, Richard G; Volgman, Annabelle S

    2015-01-01

    Portable ECG devices are widely available yet there are limited data on their accuracy, physician and patient perceptions, and ease of use. The purpose of this study was to evaluate the accuracy of 4 single-lead portable ECG devices compared to a conventional 3-lead hospital cardiac monitor and to assess physician and patient perceptions of portable ECG devices. Twenty consecutive hospitalized patients were provided 4 portable ECG devices for 30 second cardiac rhythm recording. ECG rhythm strips from the portable ECG devices were interpreted by a group of 5 physician reviewers. The reviewers then compared the portable ECG device rhythm strips to simultaneously recorded hospital cardiac monitor rhythm strips to determine physician preference. A cardiac electrophysiologist interpreted ECG rhythm strips from the hospital cardiac monitor as the "gold standard." Rhythm interpretations of the portable ECG devices and the hospital cardiac monitor were analyzed to evaluate clinical accuracy. Patient perceptions were evaluated by a 20-item questionnaire. There was less than 50% concordance of portable ECG device rhythm strips with the hospital cardiac monitor (when uninterpretable rhythm strips were included). Physicians usually preferred interpreting ECGs from hospital cardiac monitors compared to portable ECG devices. Manufacturer instructions were insufficient to allow patients to operate portable ECG devices in a limited time. Most patients felt comfortable using a portable ECG device if prescribed by a physician. Portable ECG devices may be a reasonable option for long-term rhythm surveillance in select patients. Widespread use of these devices cannot be endorsed unless improvements in their accuracy are properly addressed. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. Productivity Improvement for the SHX--SEN's Single-Wafer High-Current Ion Implanter

    International Nuclear Information System (INIS)

    Ninomiya, Shiro; Ochi, Akihiro; Kimura, Yasuhiko; Yumiyama, Toshio; Kudo, Tetsuya; Kurose, Takeshi; Kariya, Hiroyuki; Tsukihara, Mitsukuni; Ishikawa, Koji; Ueno, Kazuyoshi

    2011-01-01

    Equipment productivity is a critical issue for device fabrication. For ion implantation, productivity is determined both by ion current at the wafer and by utilization efficiency of the ion beam. Such improvements not only result in higher fabrication efficiency but also reduce consumption of both electrical power and process gases. For high-current ion implanters, reduction of implant area is a key factor to increase efficiency. SEN has developed the SAVING system (Scanning Area Variation Implantation with Narrower Geometrical pattern) to address this opportunity. In this paper, three variations of the SAVING system are introduced along with discussion of their effects on fab productivity.

  8. ions

    African Journals Online (AJOL)

    (MP2 B2). In order to draw the final conclusion about the content of the isomers of pentaatomic ions in saturated vapor over cesium chloride, we have taken into account the entropy factor. We considered the isomerization reactions which are given below: Cs3Cl2. + (V-shaped) = Cs3Cl2. + (cyclic or bipyramidal). (1). Cs2Cl3.

  9. Single potential electrodeposition of nanostructured battery materials for lithium-ion batteries

    Science.gov (United States)

    Mosby, James Matthew

    The increasing reliance on portable electronics is continuing to fuel research in the area of low power lithium-ion batteries, while a new surge in research for high power lithium-ion batteries has been sparked by the demand for plug-in hybrid electric vehicles (PHEV) and plug-in electric vehicles (PEV). To compete with current lead-acid battery chemistry, a few of the shortcomings of lithium-ion battery chemistry need to be addressed. The three main drawbacks of lithium-ion batteries for this application are: (1) low power density, (2) safety, and (3) the high cost of manufacturing. This dissertation covers the development of a low cost fabrication technique for an alternative anode material with high surface area geometries. The anode material is safer than the conventional anode material in lithium-ion batteries and the high surface area geometries permit higher power densities to be achieved. Electrodeposition is an inexpensive alternative method for synthesizing materials for electronics, energy conversion and energy storage applications relative to traditional solid state techniques. These techniques led to expensive device fabrication. Unlike most solid state synthesis routes, electrodeposition can usually be performed from common solutions and at moderate conditions. Three other benefits of using electrodeposition are: (1) it allows precise control of composition and crystallinity, (2) it provides the ability to deposit on complex shapes, and (3) it can deposit materials with nanoscale dimensions. The use of electrodeposition for alternative anode materials results in the deposition of the material directly onto the current collector that is used for the battery testing and applications without the need of additional binders and with excellent electrical contact. While this improves the characterization of the material and lowers the weight of the non-active materials within a battery, it also allows the anode to be deposited onto current collectors with

  10. Determination of trace inorganic anions in weak acids by single-pump column-switching ion chromatography.

    Science.gov (United States)

    Zhu, Haibao; Chen, Huadong; Zhong, Yingying; Ren, Dandan; Qian, Yaling; Tang, Hongfang; Zhu, Yan

    2010-08-01

    Ion chromatography has been proposed for the determination of three common inorganic anions (chloride, nitrate, and sulfate) in nine weak acids (tartaric acid, citric acid, formic acid, acetic acid, metacetonic acid, butyric acid, butanedioic acid, hexafluorophosphoric acid, and salicylic acid) using a single pump, two valves, a single eluent, and a single conductivity detector. The present system uses ion exclusion, concentrator, and anion-exchange columns connected in series via 6-port and 10-port valves in a Dionex ICS-2100 ion chromatograph. The valves were switched for the determination of three inorganic anions from weak acids in a single chromatographic run. Sample matrices of weak acids with a series of concentrations can be investigated. Complete separations of the previously mentioned anions are demonstrated within 40 min. Under the optimum conditions, the relative standard deviation values ranged from 1.3 to 3.8%. The detection limits of the three inorganic anions (S/N = 3) were in the range of 0.3-1.7 microg/L. The recoveries were in the range of 75.2-117.6%. With this system, automation for routine analysis, short analysis time, and low cost can be achieved.

  11. From single point of measurement to distributed sensing in long-term glacier monitoring

    International Nuclear Information System (INIS)

    Cesarini, Daniel; Avvenuti, Marco; Jelicic, Vana; Bilas, Vedran

    2013-01-01

    Glacial environment monitoring is a key task in understanding natural phenomena related to global warming. For the last 30 years, Automatic Weather Stations (AWSs) have been spreading among the meteorological and geophysical community, and are on the way to become a de facto standard to perform long-lasting unattended data acquisitions in single localized points of interest. Sensor Networks (SNs), on the other hand, promise the possibility to perform measurements with a higher spatial density and lower cost. Designing and developing a SN for glacial environment face particular challenges for embedded electronics and sensor systems, which is why SNs are still under research and development in this field. This paper surveys the AWSs and SNs for glacial monitoring applications and compares their characteristics.

  12. Development of a 10-decade single-mode reactor flux monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Valentine, K.H.; Shepard, R.L.; Falter, K.G.; Reese, W.B.

    1988-03-31

    Conventional wide-range neutron channels employ three optional modes to monitor the required flux range from source levels to full power (typically 10 or more decades). Difficult calibrations are necessary to provide a continuous output signal when such a system switches from counting mode in the source range to mean-square voltage mode in the midrange to dc current mode in the power range. In an ORNL proof-of-principle test, a method of extended range counting was implemented with a fission counter and conventional wide-band pulse processing electronics to provide a single-mode, monotonically increasing signal that spanned /approximately 10/ decades of neutron flux. Ongoing work includes design, fabrication, and testing of a comlpete neutron flux monitoring system suitable for advanced liquid metal reactor designs. 6 refs., 4 figs.

  13. Development of a 10-decade single-mode reactor flux monitoring system

    International Nuclear Information System (INIS)

    Valentine, K.H.; Shepard, R.L.; Falter, K.G.; Reese, W.B.

    1988-01-01

    Conventional wide-range neutron channels employ three optional modes to monitor the required flux range from source levels to full power (typically 10 or more decades). Difficult calibrations are necessary to provide a continuous output signal when such a system switches from counting mode in the source range to mean-square voltage mode in the midrange to dc current mode in the power range. In an ORNL proof-of-principle test, a method of extended range counting was implemented with a fission counter and conventional wide-band pulse processing electronics to provide a single-mode, monotonically increasing signal that spanned /approximately 10/ decades of neutron flux. Ongoing work includes design, fabrication, and testing of a comlpete neutron flux monitoring system suitable for advanced liquid metal reactor designs. 6 refs., 4 figs

  14. Monitoring the native phosphorylation state of plasma membrane proteins from a single mouse cerebellum

    DEFF Research Database (Denmark)

    Schindler, J.; Ye, J. Y.; Jensen, Ole Nørregaard

    2013-01-01

    proteins are major targets of the signalling cascades, we developed a protocol to monitor their phosphorylation state starting from a single mouse cerebellum. An aqueous polymer two-phase system was used to enrich for plasma membrane proteins. Subsequently, calcium phosphate precipitation, immobilized...... metal affinity chromatography, and TiO2 were combined to a sequential extraction procedure prior to mass spectrometric analyses. This strategy resulted in the identification of 1501 different native phosphorylation sites in 507 different proteins. 765 (51%) of these phosphorylation sites were localized...

  15. Cationized phenylalanine conformations characterized by IRMPD and computation for singly and doubly charged ions

    NARCIS (Netherlands)

    Dunbar, R. C.; Steill, J. D.; Oomens, J.

    2010-01-01

    Electrospray ionization produces phenylalanine (Phe) complexes of the alkali metal ion series, plus Ag+ and Ba2+. Infrared multiple photon dissociation (IRMPD) spectroscopy using the FELIX free electron laser light source is used to characterize the conformations of the ions, in conjunction with

  16. Early Stage of Deformation under Nanoindenter Tip of Ion-irradiated Single Crystals

    International Nuclear Information System (INIS)

    Shin, Chan Sun; Jin, Hyung Ha; Kwon, Jun Hyun

    2010-01-01

    Ion irradiation has been used for almost 40 years to emulate the effect of neutrons. Ion irradiation has a number of advantages in terms of time and expenses compared to neutron irradiation. Ion irradiation is expected to greatly contribute to the development of Fusion and Gen IV materials. Ions have short penetration depth, and they induce continuously varying dose rate over the penetration depth. Although it depends on the energy and species of incident ions, the depth of ion-irradiated region is in general on the order of a few micron meters. Depth controlled probing technique is required to measure the mechanical properties of ion-irradiated layer, and nanoindentation is widely used. During nanoindentation, a hard tip with known properties is pressed into a material which has unknown properties. The depth of penetration and load on the indenter are recorded during loading and unloading. The initial Loading depth curve follows the Hertzian elastic solution, and at a certain load, a sudden displacement excursion occurs in indenter depth and then hardening follows. This is called 'Pop-in' event, and since residual impression can be found only after pop-ins, the pop-in is regarded as the onset of plasticity. The objectives of this research are to investigate the effects of ion irradiation on popins, and to examine dislocation nucleation and propagation at the onset of plasticity by using MD simulations

  17. Early Stage of Deformation under Nanoindenter Tip of Ion-irradiated Single Crystals

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Chan Sun; Jin, Hyung Ha; Kwon, Jun Hyun [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-10-15

    Ion irradiation has been used for almost 40 years to emulate the effect of neutrons. Ion irradiation has a number of advantages in terms of time and expenses compared to neutron irradiation. Ion irradiation is expected to greatly contribute to the development of Fusion and Gen IV materials. Ions have short penetration depth, and they induce continuously varying dose rate over the penetration depth. Although it depends on the energy and species of incident ions, the depth of ion-irradiated region is in general on the order of a few micron meters. Depth controlled probing technique is required to measure the mechanical properties of ion-irradiated layer, and nanoindentation is widely used. During nanoindentation, a hard tip with known properties is pressed into a material which has unknown properties. The depth of penetration and load on the indenter are recorded during loading and unloading. The initial Loading depth curve follows the Hertzian elastic solution, and at a certain load, a sudden displacement excursion occurs in indenter depth and then hardening follows. This is called 'Pop-in' event, and since residual impression can be found only after pop-ins, the pop-in is regarded as the onset of plasticity. The objectives of this research are to investigate the effects of ion irradiation on popins, and to examine dislocation nucleation and propagation at the onset of plasticity by using MD simulations

  18. Potent neutralization of influenza A virus by a single-domain antibody blocking M2 ion channel protein.

    Directory of Open Access Journals (Sweden)

    Guowei Wei

    Full Text Available Influenza A virus poses serious health threat to humans. Neutralizing antibodies against the highly conserved M2 ion channel is thought to offer broad protection against influenza A viruses. Here, we screened synthetic Camel single-domain antibody (VHH libraries against native M2 ion channel protein. One of the isolated VHHs, M2-7A, specifically bound to M2-expressed cell membrane as well as influenza A virion, inhibited replication of both amantadine-sensitive and resistant influenza A viruses in vitro, and protected mice from a lethal influenza virus challenge. Moreover, M2-7A showed blocking activity for proton influx through M2 ion channel. These pieces of evidence collectively demonstrate for the first time that a neutralizing antibody against M2 with broad specificity is achievable, and M2-7A may have potential for cross protection against a number of variants and subtypes of influenza A viruses.

  19. Optical planar waveguides in photo-thermal-refractive glasses fabricated by single- or double-energy carbon ion implantation

    Science.gov (United States)

    Wang, Yue; Shen, Xiao-Liang; Zheng, Rui-Lin; Guo, Hai-Tao; Lv, Peng; Liu, Chun-Xiao

    2018-01-01

    Ion implantation has demonstrated to be an efficient and reliable technique for the fabrication of optical waveguides in a diversity of transparent materials. Photo-thermal-refractive glass (PTR) is considered to be durable and stable holographic recording medium. Optical planar waveguide structures in the PTR glasses were formed, for the first time to our knowledge, by the C3+-ion implantation with single-energy (6.0 MeV) and double-energy (5.5+6.0 MeV), respectively. The process of the carbon ion implantation was simulated by the stopping and range of ions in matter code. The morphologies of the waveguides were recorded by a microscope operating in transmission mode. The guided beam distributions of the waveguides were measured by the end-face coupling technique. Comparing with the single-energy implantation, the double-energy implantation improves the light confinement for the dark-mode spectrum. The guiding properties suggest that the carbon-implanted PTR glass waveguides have potential for the manufacture of photonic devices.

  20. Junctionless Diode Enabled by Self-Bias Effect of Ion Gel in Single-Layer MoS2 Device.

    Science.gov (United States)

    Khan, Muhammad Atif; Rathi, Servin; Park, Jinwoo; Lim, Dongsuk; Lee, Yoontae; Yun, Sun Jin; Youn, Doo-Hyeb; Kim, Gil-Ho

    2017-08-16

    The self-biasing effects of ion gel from source and drain electrodes on electrical characteristics of single layer and few layer molybdenum disulfide (MoS 2 ) field-effect transistor (FET) have been studied. The self-biasing effect of ion gel is tested for two different configurations, covered and open, where ion gel is in contact with either one or both, source and drain electrodes, respectively. In open configuration, the linear output characteristics of the pristine device becomes nonlinear and on-off ratio drops by 3 orders of magnitude due to the increase in "off" current for both single and few layer MoS 2 FETs. However, the covered configuration results in a highly asymmetric output characteristics with a rectification of around 10 3 and an ideality factor of 1.9. This diode like behavior has been attributed to the reduction of Schottky barrier width by the electric field of self-biased ion gel, which enables an efficient injection of electrons by tunneling at metal-MoS 2 interface. Finally, finite element method based simulations are carried out and the simulated results matches well in principle with the experimental analysis. These self-biased diodes can perform a crucial role in the development of high-frequency optoelectronic and valleytronic devices.

  1. Elucidating distinct ion channel populations on the surface of hippocampal neurons via single-particle tracking recurrence analysis

    Science.gov (United States)

    Sikora, Grzegorz; Wyłomańska, Agnieszka; Gajda, Janusz; Solé, Laura; Akin, Elizabeth J.; Tamkun, Michael M.; Krapf, Diego

    2017-12-01

    Protein and lipid nanodomains are prevalent on the surface of mammalian cells. In particular, it has been recently recognized that ion channels assemble into surface nanoclusters in the soma of cultured neurons. However, the interactions of these molecules with surface nanodomains display a considerable degree of heterogeneity. Here, we investigate this heterogeneity and develop statistical tools based on the recurrence of individual trajectories to identify subpopulations within ion channels in the neuronal surface. We specifically study the dynamics of the K+ channel Kv1.4 and the Na+ channel Nav1.6 on the surface of cultured hippocampal neurons at the single-molecule level. We find that both these molecules are expressed in two different forms with distinct kinetics with regards to surface interactions, emphasizing the complex proteomic landscape of the neuronal surface. Further, the tools presented in this work provide new methods for the analysis of membrane nanodomains, transient confinement, and identification of populations within single-particle trajectories.

  2. Molecular dynamics study of radiation damage and microstructure evolution of zigzag single-walled carbon nanotubes under carbon ion incidence

    Science.gov (United States)

    Li, Huan; Tang, Xiaobin; Chen, Feida; Huang, Hai; Liu, Jian; Chen, Da

    2016-07-01

    The radiation damage and microstructure evolution of different zigzag single-walled carbon nanotubes (SWCNTs) were investigated under incident carbon ion by molecular dynamics (MD) simulations. The radiation damage of SWCNTs under incident carbon ion with energy ranging from 25 eV to 1 keV at 300 K showed many differences at different incident sites, and the defect production increased to the maximum value with the increase in incident ion energy, and slightly decreased but stayed fairly stable within the majority of the energy range. The maximum damage of SWCNTs appeared when the incident ion energy reached 200 eV and the level of damage was directly proportional to incident ion fluence. The radiation damage was also studied at 100 K and 700 K and the defect production decreased distinctly with rising temperature because radiation-induced defects would anneal and recombine by saturating dangling bonds and reconstructing carbon network at the higher temperature. Furthermore, the stability of a large-diameter tube surpassed that of a thin one under the same radiation environments.

  3. Investigations on heavy ion induced Single-Event Transients (SETs) in highly-scaled FinFETs

    International Nuclear Information System (INIS)

    Gaillardin, M.; Raine, M.; Paillet, P.; Adell, P.C.; Girard, S.; Duhamel, O.; Andrieu, F.; Barraud, S.; Faynot, O.

    2015-01-01

    We investigate Single-Event Transients (SET) in different designs of multiple-gate devices made of FinFETs with various geometries. Heavy ion experimental results are explained by using a thorough charge collection analysis of fast transients measured on dedicated test structures. Multi-level simulations are performed to get new insights into the charge collection mechanisms in multiple-gate devices. Implications for multiple-gate device design hardening are finally discussed.

  4. Tumor induction in mice after local irradiation with single doses of either carbon-ion beams or gamma rays.

    Science.gov (United States)

    Ando, Koichi; Koike, Sachiko; Ohmachi, Yasushi; Ando, Yutaka; Kobashi, Gen

    2014-12-01

    To determine the dose-dependent relative biological effectiveness (RBE) for tumor prevalence in mice receiving single localized doses to their right leg of either carbon ions (15, 45 or 75 keV/μm) or 137Cs gamma rays. A total of 1647 female C3H mice were irradiated to their hind legs with a localized dose of either reference gamma rays or 15, 45 or 75 keV/μm carbon-ion beams. Irradiated mice were evaluated for tumors twice a month during their three-year life span, and the dimensions of any tumors found were measured with a caliper. The tumor induction frequency was calculated by Kaplan-Meier analysis. The incidence of tumors from 50 Gy of 45 keV/μm carbon ions was marginally higher than those from 50 Gy of gamma rays. However, 60 Gy of 15 keV/μm carbon ions induced significantly fewer tumors than did gamma rays. RBE values of 0.87 + 0.12, 1.29 + 0.08 or 2.06 + 0.39 for lifetime tumorigenesis were calculated for 15, 45 or 75 keV/μm carbon-ion beams, respectively. Fibrosarcoma predominated, with no Linear Energy Transfer (LET)-dependent differences in the tumor histology. Experiments measuring the late effect of leg skin shrinkage suggested that the carcinogenic damage of 15 keV/μm carbon ions would be less than that of gamma rays. We conclude that patients receiving radiation doses to their normal tissues would face less risk of secondary tumor induction by carbon ions of intermediate LET values compared to equivalent doses of photons.

  5. Determination and shaping of the ion-velocity distribution function in a single-ended Q machine

    DEFF Research Database (Denmark)

    Andersen, S.A.; Jensen, Vagn Orla; Michelsen, Poul

    1971-01-01

    An electrostatic energy analyzer with a resolution better than 0.03 eV was constructed. This analyzer was used to determine the ion-velocity distribution function at different densities and plate temperatures in a single-ended Q machine. In all regions good agreement with theoretical predictions...... based on simple, physical pictures is obtained. It is shown that within certain limits the velocity distribution function can be shaped; double-humped distribution functions have been obtained. The technique used here is suggested as an accurate method for determination of plasma densities within 10......% in single-ended Q machines...

  6. Application of laser tweezers Raman spectroscopy techniques to the monitoring of single cell response to stimuli

    Science.gov (United States)

    Chan, James W.; Liu, Rui; Matthews, Dennis L.

    2012-06-01

    Laser tweezers Raman spectroscopy (LTRS) combines optical trapping with micro-Raman spectroscopy to enable label-free biochemical analysis of individual cells and small biological particles in suspension. The integration of the two technologies greatly simplifies the sample preparation and handling of suspension cells for spectroscopic analysis in physiologically meaningful conditions. In our group, LTRS has been used to study the effects of external perturbations, both chemical and mechanical, on the biochemistry of the cell. Single cell dynamics can be studied by performing longitudinal studies to continuously monitor the response of the cell as it interacts with its environment. The ability to carry out these measurements in-vitro makes LTRS an attractive tool for many biomedical applications. Here, we discuss the use of LTRS to study the response of cancer cells to chemotherapeutics and bacteria cells to antibiotics and show that the life cycle and apoptosis of the cells can be detected. These results show the promise of LTRS for drug discovery/screening, antibiotic susceptibility testing, and chemotherapy response monitoring applications. In separate experiments, we study the response of red blood cells to the mechanical forces imposed on the cell by the optical tweezers. A laser power dependent deoxygenation of the red blood cell in the single beam trap is reported. Normal, sickle cell, and fetal red blood cells have a different behavior that enables the discrimination of the cell types based on this mechanochemical response. These results show the potential utility of LTRS for diagnosing and studying red blood cell diseases.

  7. Determination of cross sections of nuclear reactions to use Al as monitoring foil in heavy ion irradiation with 20Ne projectile

    International Nuclear Information System (INIS)

    Chowdhury, D.P.; Datta, J.; Guin, R.; Verma, R.

    2009-01-01

    The beam current is generally accurately measured using monitoring foils during the irradiation of thick samples by high energy ion beams. The cross sections of many nuclear reactions induced by light particles are available in literature for use as monitoring foil. However, such cross sections of heavy ion induced reactions are not reported much for their use in applied works. We have determined cross sections of two nuclear reactions, 27 Al ( 20 Ne,2p2n) 43 Sc and 27 Al ( 20 Ne, 2pn) 44m Sc, to use Al as monitoring foil for the irradiation with 20 Ne heavy ion beam. (author)

  8. Cavity-Enhanced Real-Time Monitoring of Single-Charge Jumps at the Microsecond Time Scale

    Science.gov (United States)

    Arnold, C.; Loo, V.; Lemaître, A.; Sagnes, I.; Krebs, O.; Voisin, P.; Senellart, P.; Lanco, L.

    2014-04-01

    We use fast coherent reflectivity measurements, in a strongly coupled quantum dot micropillar device, to monitor in real time single-charge jumps at the microsecond time scale. Thanks to the strong enhancement of light-matter interaction inside the cavity, and to a close to shot-noise-limited detection setup, the measurement rate is 5 orders of magnitude faster than with previous optical experiments of direct single-charge sensing with quantum dots. The monitored transitions, identified at any given time with a less than 0.2% error probability, correspond to a carrier being captured and then released by a single material defect. This high-speed technique opens the way for the real-time monitoring of other rapid single quantum events, such as the quantum jumps of a single spin.

  9. Functions and requirements for Hanford single-shell tank leakage detection and monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Cruse, J.M.; Ohl, P.C.

    1995-04-19

    This document provides the initial functions and requirements for leakage detection and monitoring applicable to past and potential future leakage from the Hanford Site`s 149 single-shell high-level waste tanks. This mission is a part of the overall mission of the Westinghouse Hanford Company Tank Waste Remediation System division to remediate the tank waste in a safe and acceptable manner. Systems engineering principles are being applied to this effort. This document reflects the an initial step in the systems engineering approach to decompose the mission into primary functions and requirements. The document is considered approximately 30% complete relative to the effort required to produce a final version that can be used to support demonstration and/or procurement of technologies. The functions and requirements in this document apply to detection and monitoring of below ground leaks from SST containment boundaries and the resulting soil contamination. Leakage detection and monitoring is invoked in the TWRS Program in three fourth level functions: (1) Store Waste, (2) Retrieve Waste, and (3) Disposition Excess Facilities (as identified in DOE/RL-92-60 Rev. 1, Tank Waste Remediation System Functions and Requirements).

  10. Sensor system for multi-point monitoring using bending loss of single mode optical fiber

    International Nuclear Information System (INIS)

    Kim, Heon Young; Kim, Dae Hyun

    2015-01-01

    Applications of smart sensors have been extended to safety systems in the aerospace, transportation and civil engineering fields. In particular, structural health monitoring techniques using smart sensors have gradually become necessary and have been developed to prevent dangers to human life and damage to assets. Generally, smart sensors are based on electro-magnets and have several weaknesses, including electro-magnetic interference and distortion. Therefore, fiber optic sensors are an outstanding alternative to overcome the weaknesses of electro-magnetic sensors. However, they require expensive devices and complex systems. This paper proposes a new, affordable and simple sensor system that uses a single fiber to monitor pressures at multiple-points. Moreover, a prototype of the sensor system was manufactured and tested for a feasibility study. Based on the results of this experimental test, a relationship was carefully observed between the bend loss conditions and light-intensity. As a result, it was shown that impacts at multiple-points could be monitored.

  11. Fast Data Acquisition in Heavy Ion CT Using Intensifying Screen—EMCCD Camera System With Beam Intensity Monitor

    Science.gov (United States)

    Muraishi, Hiroshi; Abe, Shinji; Satoh, Hitoshi; Hara, Hidetake; Mogaki, Tatsuya; Hara, Satoshi; Miyake, Shoko; Watanabe, Yusuke; Koba, Yusuke

    2012-10-01

    We investigated the feasibility of fast data acquisition in heavy ion CT (IonCT) technique with an X-ray intensifying screen-charged coupled device (CCD) camera system. This technique is based on measuring the residual range distribution of heavy ions after passing through an object. We took a large number of images with a CCD camera for one projection by changing the range shifter (RS) thickness to obtain a characteristic curve similar to a Bragg curve and then to estimate the relative residual range. We used a high quality Electron Multiplying CCD (EMCCD) camera, which drastically reduced data acquisition time. We also used a parallel-plate ionization chamber upstream of an object to monitor the time variation in heavy ion beam intensity from a synchrotron accelerator and to perform beam intensity correction for all EMCCD images. Experiments were conducted using a broad beam of 12C, which was generated by spreading out the pencil beam accelerated up to 400 MeV/u by the Heavy Ion Medical Accelerator, in Chiba (HIMAC) at the National Institute of Radiological Sciences, with a scatterer. We demonstrated that a fast CT data acquisition, 14 min for 256 projections, is possible for an electron density phantom, consisting of six rods with a relative electron density resolution of 0.017, using the proposed technique with HIMAC.

  12. Lithium ions in the van der Waals gap of Bi2Se3 single crystals

    International Nuclear Information System (INIS)

    Bludska, J.; Jakubec, I.; Karamazov, S.; Horak, J.; Uher, C.

    2010-01-01

    Insertion/extraction of lithium ions into/from Bi 2 Se 3 crystals was investigated by means of cyclic voltammetry. The process of insertion is reflected in the appearance of two bands on voltammograms at ∼1.7 and ∼1.5 V, corresponding to the insertion of Li + ions into octahedral and tetrahedral sites of the van der Waals gap of these layered crystals. The process of extraction of Li + ions from the gap results in the appearance of four bands on the voltammograms. The bands 1 and 2 at ∼2.1 and ∼2.3 V correspond to the extraction of a part of Li + guest ions from the octahedral and tetrahedrals sites and this extraction has a character of a reversible intercalation/deintercalation process. A part of Li + ions is bound firmly in the crystal due to the formation of negatively charged clusters of the (LiBiSe 2 .Bi 3 Se 4 - ) type. A further extraction of Li + ions from the van der Waals gap is associated with the presence of bands 3 and 4 placed at ∼2.5 and ∼2.7 V on the voltammograms as their extraction needs higher voltage due to the influence of negative charges localized on these clusters. -- Graphical abstract: Insertion/extraction of lithium ions into/from Bi 2 Se 3 layered crystals was investigated by cyclic voltammetry. The extraction of Li + results in the appearance of four bands on the voltammograms. The first two bands have a character of a reversible process. A part of Li + ions is bound firmly in the crystal due to the formation of negatively charged clusters of the (LiBiSe 2 .Bi 3 Se 4 - ) type. Their extraction needs higher voltage due to the negative charge. Display Omitted

  13. Nanometer-size surface modification produced by single, low energy, highly charged ions

    International Nuclear Information System (INIS)

    Stockli, M.P.

    1994-01-01

    Atomically flat surfaces of insulators have been bombarded with low energy, highly charged ions to search for nanometer-size surface modifications. It is expected that the high electron deficiency of highly charged ions will capture and/or remove many of the insulator's localized electrons when impacting on an insulating surface. The resulting local electron deficiency is expected to locally disintegrate the insulator through a open-quotes Coulomb explosionclose quotes forming nanometer-size craters. Xe ions with charge states between 10+ and 45+ and kinetic energies between 0 and 10 keV/q were obtained from the KSU-CRYEBIS, a CRYogenic Electron Beam Ion Source and directed onto various insulating materials. Mica was favored as target material as atomically flat surfaces can be obtained reliably through cleaving. However, the authors observations with an atomic force microscope have shown that mica tends to defoliate locally rather than disintegrate, most likely due to the small binding forces between adjacent layers. So far the authors measurements indicate that each ion produces one blister if the charge state is sufficiently high. The blistering does not seem to depend very much on the kinetic energy of the ions

  14. Cluster-continuum quasichemical theory calculation of the lithium ion solvation in water, acetonitrile and dimethyl sulfoxide: an absolute single-ion solvation free energy scale.

    Science.gov (United States)

    Carvalho, Nathalia F; Pliego, Josefredo R

    2015-10-28

    Absolute single-ion solvation free energy is a very useful property for understanding solution phase chemistry. The real solvation free energy of an ion depends on its interaction with the solvent molecules and on the net potential inside the solute cavity. The tetraphenyl arsonium-tetraphenyl borate (TATB) assumption as well as the cluster-continuum quasichemical theory (CC-QCT) approach for Li(+) solvation allows access to a solvation scale excluding the net potential. We have determined this free energy scale investigating the solvation of the lithium ion in water (H2O), acetonitrile (CH3CN) and dimethyl sulfoxide (DMSO) solvents via the CC-QCT approach. Our calculations at the MP2 and MP4 levels with basis sets up to the QZVPP+diff quality, and including solvation of the clusters and solvent molecules by the dielectric continuum SMD method, predict the solvation free energy of Li(+) as -116.1, -120.6 and -123.6 kcal mol(-1) in H2O, CH3CN and DMSO solvents, respectively (1 mol L(-1) standard state). These values are compatible with the solvation free energy of the proton of -253.4, -253.2 and -261.1 kcal mol(-1) in H2O, CH3CN and DMSO solvents, respectively. Deviations from the experimental TATB scale are only 1.3 kcal mol(-1) in H2O and 1.8 kcal mol(-1) in DMSO solvents. However, in the case of CH3CN, the deviation reaches a value of 9.2 kcal mol(-1). The present study suggests that the experimental TATB scale is inconsistent for CH3CN. A total of 125 values of the solvation free energy of ions in these three solvents were obtained. These new data should be useful for the development of theoretical solvation models.

  15. Oxygen saturation and heart rate monitoring during a single session of early rehabilitation after cardiac surgery.

    Science.gov (United States)

    Sala, Vittorio; Petrucci, Lucia; Monteleone, Serena; Dall'Angelo, Anna; Miracca, Stefania; Conte, Teresa; Carlisi, Ettore; Ricotti, Susanna; D'Armini, Andrea M; Dalla Toffola, Elena

    2016-02-01

    Early rehabilitation after cardiac surgery aims to prevent immobilization, to reduce the effects of surgery on the respiratory function and to facilitate the recovery of autonomy in the activities of daily living (ADL), after discharge. Nevertheless the optimal perioperative physical therapy care for patients undergoing cardiac surgery is not well established. Moreover, most of the studies monitored peripheral oxygen saturation (SpO2) and heart rate (HR) during surgery or focused only on their recovery after rehabilitation and not on their pathways during a session of exercises. To monitor peripheral oxygen saturation and HR before, during and at the end of a single session of early rehabilitation after cardiac surgery, so testing our protocol's safety. A case series. Department of Cardiothoracic Surgery, inpatients. Forty-eight consecutive inpatients (35 M), mean age 61 years, with cardiovascular disease (CVD), who underwent cardiac surgery. We monitored SpO2%, HR, systemic blood pressure (BP), pain in the thoracic wound (VAS) and rate of perceived exertion (RPE) during the rehabilitation session after weaning from oxygen therapy. During all phases mean SpO2 was 94% (±1.8) and mean HR was 85 bpm (±13.3). Number of desaturation events were 14 in total and mean of % of time with SpO2<90% was 3 (±6.5) during all the rehabilitative session. Moreover, mean BP after reaching the sitting position was 124.7 (±11.9)/78.6 (±8.4) and after ambulation was 131.5 (±11.5)/82.9 (±7.3). The monitoring peripheral oxygen saturation and HR during and not only before and at the end of a standardized early rehabilitation session helped us to ensure the safety of our protocol. Because of its feasibility, safety and reproducibility our rehabilitation treatment has been applied to different types of surgical inpatients in order to limit the negative consequences of immobilization.

  16. Connecting to concrete: wireless monitoring of chloride ions in concrete structures

    NARCIS (Netherlands)

    Abbas, Yawar; ten Have, Bas; Hoekstra, Gerrit I.; Douma, Arjan; de Bruijn, Douwe; Olthuis, Wouter; van den Berg, Albert

    2015-01-01

    For the first time, chloride ions are measured wirelessly in concrete. The half-cell potential of a silver/silver chloride (Ag/AgCl) electrode, which corresponds to the concentration of chloride ions, is measured wirelessly. The sensor system (the Ag/AgCl and a reference electrode) is embedded in

  17. Monitoring single-synapse glutamate release and presynaptic calcium concentration in organised brain tissue.

    Science.gov (United States)

    Jensen, Thomas P; Zheng, Kaiyu; Tyurikova, Olga; Reynolds, James P; Rusakov, Dmitri A

    2017-06-01

    Brain function relies in large part on Ca 2+ -dependent release of the excitatory neurotransmitter glutamate from neuronal axons. Establishing the causal relationship between presynaptic Ca 2+ dynamics and probabilistic glutamate release is therefore a fundamental quest across neurosciences. Its progress, however, has hitherto depended primarily on the exploration of either cultured nerve cells or giant central synapses accessible to direct experimental probing in situ. Here we show that combining patch-clamp with time-resolved imaging of Ca 2+ -sensitive fluorescence lifetime of Oregon Green BAPTA-1 (Tornado-FLIM) enables readout of single spike-evoked presynaptic Ca 2+ concentration dynamics, with nanomolar sensitivity, in individual neuronal axons in acute brain slices. In parallel, intensity Tornado imaging of a locally expressed extracellular optical glutamate sensor iGluSnFr provides direct monitoring of single-quantum, single-synapse glutamate releases in situ. These two methods pave the way for simultaneous registration of presynaptic Ca 2+ dynamics and transmitter release in an intact brain at the level of individual synapses. Copyright © 2017. Published by Elsevier Ltd.

  18. Monitoring single membrane protein dynamics in a liposome manipulated in solution by the ABELtrap

    Science.gov (United States)

    Rendler, T.; Renz, M.; Hammann, E.; Ernst, S.; Zarrabi, N.; Börsch, M.

    2011-02-01

    FoF1-ATP synthase is the essential membrane enzyme maintaining the cellular level of adenosine triphosphate (ATP) and comprises two rotary motors. We measure subunit rotation in FoF1-ATP synthase by intramolecular Foerster resonance energy transfer (FRET) between two fluorophores at the rotor and at the stator of the enzyme. Confocal FRET measurements of freely diffusing single enzymes in lipid vesicles are limited to hundreds of milliseconds by the transit times through the laser focus. We evaluate two different methods to trap the enzyme inside the confocal volume in order to extend the observation times. Monte Carlo simulations show that optical tweezers with low laser power are not suitable for lipid vesicles with a diameter of 130 nm. A. E. Cohen (Harvard) and W. E. Moerner (Stanford) have recently developed an Anti-Brownian electrokinetic trap (ABELtrap) which is capable to apparently immobilize single molecules, proteins, viruses or vesicles in solution. Trapping of fluorescent particles is achieved by applying a real time, position-dependent feedback to four electrodes in a microfluidic device. The standard deviation from a given target position in the ABELtrap is smaller than 200 nm. We develop a combination of the ABELtrap with confocal FRET measurements to monitor single membrane enzyme dynamics by FRET for more than 10 seconds in solution.

  19. Selective ion monitoring of quinochalcone C-glycoside markers for the simultaneous identification of Carthamus tinctorius L. in eleven Chinese patent medicines by UHPLC/QTOF MS.

    Science.gov (United States)

    Si, Wei; Yang, Wenzhi; Guo, Dean; Wu, Jia; Zhang, Jingxian; Qiu, Shi; Yao, Changliang; Cui, Yajun; Wu, Wanying

    2016-01-05

    Current China Pharmacopoeia standards for the Chinese patent medicines (CPMs) that contain one or several the same drug(s) employ case-dependent TLC or HPLC approaches to achieve qualitative identification. A qualitative "monomethod-heterotrait matrix" (MHM) strategy is thus proposed, by selective monitoring of multi-biomarkers, to achieve the identification of different CPMs. Carthamus tinctorius L. (safflower) is a reputable gynecological herbal medicine containing characteristic quinochalcone C-glycosides (QCGs) as the major bioactive components. Qualitative identification of safflower in diverse CPMs by selective monitoring of QCG markers was performed by use of the MHM strategy. Initially, 27 QCG analogs (involving 16 potentially new ones) were selectively characterized by product ion filtering (m/z 119.05) and integrated analysis of the negative mode MS(E) and Fast DDA data obtained on a UHPLC/QTOF mass spectrometer. Subsequently, by fingerprint analysis of 20 batches of safflower samples followed by a thermostable test, six QCGs (hydroxysafflor yellow A and its two isomers, anhydrosafflor yellow B, safflomin C, and isosafflomin C) were selected as the biomarkers for safflower. Then, a highly specific selective ion monitoring (SIM) method by recording centroided data was developed and applied to selectively profile six QCG biomarkers from 28 batches of CPM samples collected from versatile vendors. By reference to a standard SIM spectrum established using a home-made safflower reference extract, simultaneous identification of safflower in eleven different CPMs was accomplished with the unified sample preparation and a single UHPLC/QTOF-SIM method. The qualitative MHM strategy represents the novel methodology that facilitates the quality control of CPMs more efficiently. Copyright © 2015 Elsevier B.V. All rights reserved.

  20. Interaction of singly and multiply charged ions with a lithium-fluoride surface

    CERN Document Server

    Wirtz, L

    2001-01-01

    Charge transfer between slow ions and an ionic crystal surface still poses a considerable challenge to theory due to the intrinsic many-body character of the system. For the neutralization of multiply charged ions in front of metal surfaces, the Classical Over the Barrier (COB) model is a widely used tool. We present an extension of this model to ionic crystal surfaces where the localization of valence electrons at the anion sites and the lack of cylindrical symmetry of the ion-surface system impede a simple analytical estimate of electron transfer rates. We use a classical trajectory Monte Carlo approach to calculate electron transfer rates for different charge states of the projectile ion. With these rates we perform a Monte Carlo simulation of the neutralization of slow Ne10+ ions in vertical incidence on an LiF surface. Capture of one or several electrons may lead to a local positive charge up of the surface. The projectile dynamics depends on the balance between the repulsion due to this charge and the a...

  1. Single and binary adsorption of heavy metal ions from aqueous solutions using sugarcane cellulose-based adsorbent.

    Science.gov (United States)

    Wang, Futao; Pan, Yuanfeng; Cai, Pingxiong; Guo, Tianxiang; Xiao, Huining

    2017-10-01

    A high efficient and eco-friendly sugarcane cellulose-based adsorbent was prepared in an attempt to remove Pb 2+ , Cu 2+ and Zn 2+ from aqueous solutions. The effects of initial concentration of heavy metal ions and temperature on the adsorption capacity of the bioadsorbent were investigated. The adsorption isotherms showed that the adsorption of Pb 2+ , Cu 2+ and Zn 2+ followed the Langmuir model and the maximum adsorptions were as high as 558.9, 446.2 and 363.3mg·g -1 , respectively, in single component system. The binary component system was better described with the competitive Langmuir isotherm model. The three dimensional sorption surface of binary component system demonstrated that the presence of Pb 2+ decreased the sorption of Cu 2+ , but the adsorption amount of other metal ions was not affected. The result from SEM-EDAX revealed that the adsorption of metal ions on bioadsorbent was mainly driven by coordination, ion exchange and electrostatic association. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Single-ion triblock copolymer electrolytes based on poly(ethylene oxide) and methacrylic sulfonamide blocks for lithium metal batteries

    Science.gov (United States)

    Porcarelli, Luca; Aboudzadeh, M. Ali; Rubatat, Laurent; Nair, Jijeesh R.; Shaplov, Alexander S.; Gerbaldi, Claudio; Mecerreyes, David

    2017-10-01

    Single-ion conducting polymer electrolytes represent the ideal solution to reduce concentration polarization in lithium metal batteries (LMBs). This paper reports on the synthesis and characterization of single-ion ABA triblock copolymer electrolytes comprising PEO and poly(lithium 1-[3-(methacryloyloxy)propylsulfonyl]-1-(trifluoromethylsulfonyl)imide) blocks, poly(LiMTFSI). Block copolymers are prepared by reversible addition-fragmentation chain transfer polymerization, showing low glass transition temperature (-55 to 7 °C) and degree of crystallinity (51-0%). Comparatively high values of ionic conductivity are obtained (up to ≈ 10-4 S cm-1 at 70 °C), combined with a lithium-ion transference number close to unity (tLi+ ≈ 0.91) and a 4 V electrochemical stability window. In addition to these promising features, solid polymer electrolytes are successfully tested in lithium metal cells at 70 °C providing long lifetime up to 300 cycles, and stable charge/discharge cycling at C/2 (≈100 mAh g-1).

  3. Analysis of trace inorganic anions in weak acid salts by single pump cycling-column-switching ion chromatography.

    Science.gov (United States)

    Huang, Zhongping; Ni, Chengzhu; Zhu, Zhuyi; Pan, Zaifa; Wang, Lili; Zhu, Yan

    2015-05-01

    The application of ion chromatography with the single pump cycling-column-switching technique was described for the analysis of trace inorganic anions in weak acid salts within a single run. Due to the hydrogen ions provided by an anion suppressor electrolyzing water, weak acid anions could be transformed into weak acids, existing as molecules, after passing through the suppressor. Therefore, an anion suppressor and ion-exclusion column were adopted to achieve on-line matrix elimination of weak acid anions with high concentration for the analysis of trace inorganic anions in weak acid salts. A series of standard solutions consisting of target anions of various concentrations from 0.005 to 10 mg/L were analyzed, with correlation coefficients r ≥ 0.9990. The limits of detection were in the range of 0.67 to 1.51 μg/L, based on the signal-to-noise ratio of 3 and a 25 μL injection volume. Relative standard deviations for retention time, peak area, and peak height were all less than 2.01%. A spiking study was performed with satisfactory recoveries between 90.3 and 104.4% for all anions. The chromatographic system was successfully applied to the analysis of trace inorganic anions in five weak acid salts. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Single-Event Effects in Power MOSFETs During Heavy Ion Irradiations Performed After Gamma-Ray Degradation

    Science.gov (United States)

    Busatto, G.; De Luca, V.; Iannuzzo, F.; Sanseverino, A.; Velardi, F.

    2013-10-01

    The robustness of commercial power metal-oxide semiconductor field-effect transistors to combined gamma-heavy ion irradiation has been investigated, evidence that the degradation of the gate oxide caused by the γ irradiation can severely corrupt the robustness to single-event effects and drastically modify the physical behavior of the device under test after the impact of a heavy ion. A decrease of the critical voltages at which destructive burnouts and gate ruptures for heavy ion impact appear, has been detected in the devices under test, which were previously irradiated with γ rays. In addition, the amount of critical voltage reduction is strictly related to the amount of the absorbed γ-ray dose. Furthermore, at the failure voltage, the behavior of the device is affected by the conduction of a current through the gate oxide. Moreover, the single-event gate rupture” of the device appears at lower voltages because of the reduction of the Fowler-Nordheim limit in the γ-irradiated devices.

  5. A Nanophase-Separated, Quasi-Solid-State Polymeric Single-Ion Conductor: Polysulfide Exclusion for Lithium–Sulfur Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jinhong; Song, Jongchan; Lee, Hongkyung; Noh, Hyungjun; Kim, Yun-Jung; Kwon, Sung Hyun; Lee, Seung Geol; Kim, Hee-Tak

    2017-04-19

    Formation of soluble polysulfide (PS), which is a key feature of lithium sulfur (Li–S) batteries, provides a fast redox kinetic based on a liquid–solid mechanism; however, it imposes the critical problem of PS shuttle. Here, we address the dilemma by exploiting a solvent-swollen polymeric single-ion conductor (SPSIC) as the electrolyte medium of the Li–S battery. The SPSIC consisting of a polymeric single-ion conductor and lithium salt-free organic solvents provides Li ion hopping by forming a nanoscale conducting channel and suppresses PS shuttle according to the Donnan exclusion principle when being employed for Li–S batteries. The organic solvents at the interface of the sulfur/carbon composite and SPSIC eliminate the poor interfacial contact and function as a soluble PS reservoir for maintaining the liquid–solid mechanism. Furthermore, the quasi-solid-state SPSIC allows the fabrication of a bipolar-type stack, which promises the realization of a high-voltage and energy-dense Li–S battery.

  6. Ion Density Analysis of Single-Stranded DNA in Liquid Crystal

    Science.gov (United States)

    Iwabata, Kazuki; Seki, Yasutaka; Toizumi, Ryota; Shimada, Yuki; Furue, Hirokazu; Sakaguchi, Kengo

    2013-09-01

    With the widespread use of liquid crystals (LCs) in liquid crystal displays, we have looked into the application of liquid crystals in biotechnology. The purpose of the study described here is to investigate the physical properties of DNA using LCs. Synthetic oligonucleotide molecules were dispersed in MLC6884, the sample injected into antiparallel cells, and the amount of mobile ions was measured. The LC cell doped with oligonucleotide molecules showed a sequence-dependent, specific correlation between oligonucleotide concentration and the amount of mobile ions in the LC cells. In the framework of the Stokes model and polyacrylamide gel electrophoresis (PAGE) analysis, we speculate that this result arises from the difference in ion mobility, which is caused by the shape of the oligonucleotide molecule in the LC.

  7. Positron bound states on hydride ions in thermochemically reduced MgO single crystals

    International Nuclear Information System (INIS)

    Monge, M.A.; Pareja, R.; Gonzalez, R.; Chen, Y.

    1996-01-01

    Positron-lifetime and Doppler-broadening techniques were used to unambiguously identify positronium hydrides in thermochemically reduced MgO crystals at low temperatures. Positrons trapped at H - ions, forming PsH, yield a lifetime of (640±40) ps, independent of temperature. Complementary evidence for this identification was provided by Doppler-broadening experiments, in which positrons were trapped at H 2- sites at low temperatures. The H 2- ions were formed via H - +e - →H 2- by the capturing of an electron released from Fe + impurity under blue-light stimulation. copyright 1996 The American Physical Society

  8. Electrical resistivity monitoring of the single heater test in Yucca Mountain

    International Nuclear Information System (INIS)

    Ramirez, A.

    1997-10-01

    Of the several thermal, mechanical and hydrological measurements being used to monitor the rockmass response in the Single Heater Test, electrical resistance tomography (ERT) is being used to monitor the movement of liquid water with a special interest in the movement of condensate out of the system. Images of resistivity change were calculated using data collected before, during and after the heating episode. This report will concentrate on the results obtained after heating ceased; previous reports discuss the results obtained during the heating phase. The changes recovered show a region of increasing resistivity approximately centered around the heater as the rock mass cooled. The size of this region grows with time and the resistivity increases become stronger. The increases in resistivity are caused by both temperature and saturation changes. The Waxman Smits model has been used to calculate rock saturation after accounting for temperature effects. The saturation estimates suggest that during the heating phase, a region of drying forms around the heater. During the cooling phase, the dry region has remained relatively stable. Wetter rock regions which developed below the heater during the heating phase, are slowly becoming smaller in size during the cooling phase. The last set of images indicate that some rewetting of the dry zone may be occurring. The accuracy of the saturation estimates depends on several factors that are only partly understood

  9. Compact Chemical Monitor for Silver Ions in Spacecraft Water Systems, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — NASA has identified silver ions as the best candidate biocide for use in the potable water system on next-generation spacecraft. Though significant work has been...

  10. Sputtering of lunar regolith simulant by protons and singly and multicharged Ar ions at solar wind energies

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, F.W., E-mail: meyerfw@ornl.gov [Physics Division, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Harris, P.R.; Taylor, C.N. [Physics Division, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Meyer III, H.M. [MST Division, Oak Ridge National Laboratory, P.O. Box 2008, Oak Ridge, TN 37831 (United States); Barghouty, A.F.; Adams, J.H. [NASA-Marshall Space Flight Center, Huntsville, AL 35812 (United States)

    2011-06-01

    We report preliminary results on sputtering of a lunar regolith simulant at room temperature by singly and multiply charged solar wind ions using quadrupole and time-of-flight (TOF) mass spectrometry approaches. Sputtering of the lunar regolith by solar-wind heavy ions may be an important particle source that contributes to the composition of the lunar exosphere, and is a possible mechanism for lunar surface ageing and compositional modification. The measurements were performed in order to assess the relative sputtering efficiency of protons, which are the dominant constituent of the solar wind, and less abundant heavier multicharged solar wind constituents, which have higher physical sputtering yields than same-velocity protons, and whose sputtering yields may be further enhanced due to potential sputtering. Two different target preparation approaches using JSC-1A AGGL lunar regolith simulant are described and compared using SEM and XPS surface analysis.

  11. Metallization of Single-Stranded Polyl by Zn2+ Ions in Neutral Solutions

    Czech Academy of Sciences Publication Activity Database

    Sorokin, V. A.; Valeev, V. A.; Usenko, E. L.; Andrushchenko, Valery

    2014-01-01

    Roč. 118, č. 43 (2014), s. 12360-12365 ISSN 1520-6106 Institutional support: RVO:61388963 Keywords : nucleic acid metallization * zinc ion * differential UV spectroscopy Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 3.302, year: 2014

  12. Spectroscopic properties of LaAlO3 single-crystal doped with Tb3+ ions

    Science.gov (United States)

    Sztolberg, D.; Brzostowski, B.; Dereń, P. J.

    2018-04-01

    LaAlO3 monocrystal doped with 0.5 wt% Tb3+ ions was grown by the Czochralski method. Absorption, emission and emission decay time were measured 300 K in the IR, visible and near UV range. The Tb3+ energy levels in LaAlO3 were assigned both from the absorption and emission spectra.

  13. Single-Ion Deconvolution of Mass Peak Overlaps for Atom Probe Microscopy.

    Science.gov (United States)

    London, Andrew J; Haley, Daniel; Moody, Michael P

    2017-04-01

    Due to the intrinsic evaporation properties of the material studied, insufficient mass-resolving power and lack of knowledge of the kinetic energy of incident ions, peaks in the atom probe mass-to-charge spectrum can overlap and result in incorrect composition measurements. Contributions to these peak overlaps can be deconvoluted globally, by simply examining adjacent peaks combined with knowledge of natural isotopic abundances. However, this strategy does not account for the fact that the relative contributions to this convoluted signal can often vary significantly in different regions of the analysis volume; e.g., across interfaces and within clusters. Some progress has been made with spatially localized deconvolution in cases where the discrete microstructural regions can be easily identified within the reconstruction, but this means no further point cloud analyses are possible. Hence, we present an ion-by-ion methodology where the identity of each ion, normally obscured by peak overlap, is resolved by examining the isotopic abundance of their immediate surroundings. The resulting peak-deconvoluted data are a point cloud and can be analyzed with any existing tools. We present two detailed case studies and discussion of the limitations of this new technique.

  14. Fluorescence-based high-throughput functional profiling of ligand-gated ion channels at the level of single cells.

    Directory of Open Access Journals (Sweden)

    Sahil Talwar

    Full Text Available Ion channels are involved in many physiological processes and are attractive targets for therapeutic intervention. Their functional properties vary according to their subunit composition, which in turn varies in a developmental and tissue-specific manner and as a consequence of pathophysiological events. Understanding this diversity requires functional analysis of ion channel properties in large numbers of individual cells. Functional characterisation of ligand-gated channels involves quantitating agonist and drug dose-response relationships using electrophysiological or fluorescence-based techniques. Electrophysiology is limited by low throughput and high-throughput fluorescence-based functional evaluation generally does not enable the characterization of the functional properties of each individual cell. Here we describe a fluorescence-based assay that characterizes functional channel properties at single cell resolution in high throughput mode. It is based on progressive receptor activation and iterative fluorescence imaging and delivers >100 dose-responses in a single well of a 384-well plate, using α1-3 homomeric and αβ heteromeric glycine receptor (GlyR chloride channels as a model system. We applied this assay with transiently transfected HEK293 cells co-expressing halide-sensitive yellow fluorescent protein and different GlyR subunit combinations. Glycine EC50 values of different GlyR isoforms were highly correlated with published electrophysiological data and confirm previously reported pharmacological profiles for the GlyR inhibitors, picrotoxin, strychnine and lindane. We show that inter and intra well variability is low and that clustering of functional phenotypes permits identification of drugs with subunit-specific pharmacological profiles. As this method dramatically improves the efficiency with which ion channel populations can be characterized in the context of cellular heterogeneity, it should facilitate systems

  15. Radiation-induced effects in MgO single crystal by 200 keV and 1 MeV Ni ion implantation

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Ryohei; Nakai, Yoshihiro; Hamaguchi, Dai [Kyoto Inst. of Tech. (Japan)] [and others

    1997-03-01

    MgO(100) single crystals were implanted with 1.0 MeV and 200 keV Ni ions between 10{sup 15} and 10{sup 17} ions/cm{sup 2} at room temperature. Before and after thermal annealing the radiation damage and the lattice location of implanted Ni ions were analyzed by using Rutherford backscattering spectrometry with channeling and optical absorption measurements. For 1.0 MeV Ni ions, the disorder of Mg atoms increased slowly with ion dose near surface region, while it increased sharply and saturated with ion dose from 2x10{sup 16} ions/cm{sup 2} near ion range. The radiation damage was recovered and implanted Ni ions diffused to the whole of crystal and occupied substitutional positions after 1400degC annealing. For 200 keV Ni ions, the disorder of Mg atoms increased with dose near ion range and had a maximum at about 5x10{sup 16} ions/cm{sup 2}. This tendency agrees with the behavior of color centers obtained from optical measurements. For thermal annealing the radiation damage did not change during 500degC annealing, but the aggregate centers appeared after 300degC annealing. (author)

  16. Non-Destructive Monitoring of Charge-Discharge Cycles on Lithium Ion Batteries using 7Li Stray-Field Imaging

    Science.gov (United States)

    Tang, Joel A.; Dugar, Sneha; Zhong, Guiming; Dalal, Naresh S.; Zheng, Jim P.; Yang, Yong; Fu, Riqiang

    2013-01-01

    Magnetic resonance imaging provides a noninvasive method for in situ monitoring of electrochemical processes involved in charge/discharge cycling of batteries. Determining how the electrochemical processes become irreversible, ultimately resulting in degraded battery performance, will aid in developing new battery materials and designing better batteries. Here we introduce the use of an alternative in situ diagnostic tool to monitor the electrochemical processes. Utilizing a very large field-gradient in the fringe field of a magnet, stray-field-imaging (STRAFI) technique significantly improves the image resolution. These STRAFI images enable the real time monitoring of the electrodes at a micron level. It is demonstrated by two prototype half-cells, graphite∥Li and LiFePO4∥Li, that the high-resolution 7Li STRAFI profiles allow one to visualize in situ Li-ions transfer between the electrodes during charge/discharge cyclings as well as the formation and changes of irreversible microstructures of the Li components, and particularly reveal a non-uniform Li-ion distribution in the graphite. PMID:24005580

  17. Decoding of single-trial auditory mismatch responses for online perceptual monitoring and neurofeedback

    Directory of Open Access Journals (Sweden)

    Alex eBrandmeyer

    2013-12-01

    Full Text Available Multivariate pattern classification methods are increasingly applied to neuroimaging data in the context of both fundamental research and in brain-computer interfacing approaches. Such methods provide a framework for interpreting measurements made at the single-trial level with respect to a set of two or more distinct mental states. Here, we define an approach in which the output of a binary classifier trained on data from an auditory mismatch paradigm can be used for online tracking of perception and as a neurofeedback signal. The auditory mismatch paradigm is known to induce distinct perceptual states related to the presentation of high- and low-probability stimuli, which are reflected in event-related potential (ERP components such as the mismatch negativity (MMN. In the first part of the paper, we illustrate how pattern classification methods can be applied to data collected in an MMN paradigm, including discussion of the optimization of preprocessing steps, the interpretation of features and how the performance of these methods generalizes across individual participants and measurement sessions. We then go on to show that the output of these decoding methods can be used in online settings as a continuous index of single-trial brain activation underlying perceptual discrimination. We conclude by discussing several potential domains of application, including neurofeedback, cognitive monitoring and passive brain-computer interfaces.

  18. Generation of vacancy cluster-related defects during single MeV silicon ion implantation of silicon

    Energy Technology Data Exchange (ETDEWEB)

    Pastuović, Ž., E-mail: zkp@ansto.gov.au [Australian Nuclear Science and Technology Organization, Locked Bag 2001, Kirrawee DC NSW 2232 (Australia); Capan, I. [Ruđer Bošković Institute, Bijenička cesta 54, P.O. Box 180, 10002 Zagreb (Croatia); Siegele, R. [Australian Nuclear Science and Technology Organization, Locked Bag 2001, Kirrawee DC NSW 2232 (Australia); Jačimović, R. [Jozef Stefan Institute, 1000 Ljubljana (Slovenia); Forneris, J. [Physics Department and NIS Excellence Centre, University of Torino, INFN – sez. Torino, CNISM – sez. Torino, via P. Giuria 1, 10125 Torino (Italy); Cohen, D.D. [Australian Nuclear Science and Technology Organization, Locked Bag 2001, Kirrawee DC NSW 2232 (Australia); Vittone, E. [Physics Department and NIS Excellence Centre, University of Torino, INFN – sez. Torino, CNISM – sez. Torino, via P. Giuria 1, 10125 Torino (Italy)

    2014-08-01

    Deep Level Transient Spectroscopy (DLTS) has been used to study defects formed in bulk silicon after implantation of 8.3 MeV {sup 28}Si{sup 3+} ions at room temperature. For this study, Schottky diodes prepared from n-type Czohralski-grown silicon wafers have been implanted in the single ion regime up to fluence value of 1 × 10{sup 10} cm{sup −2} utilizing the scanning focused ion microbeam as implantation tool and the Ion Beam Induced Current (IBIC) technique for ion counting. Differential DLTS analysis of the vacancy-rich region in self-implanted silicon reveals a formation of the broad vacancy-related defect state(s) at E{sub c} −0.4 eV. Direct measurements of the electron capture kinetics associated with this trap at E{sub c} −0.4 eV, prior to any annealing do not show an exponential behaviour typical for the simple point-like defects. The logarithmic capture kinetics is in accordance with the theory of majority carrier capture at extended or cluster-related defects. We have detected formation of two deep electron traps at E{sub c} −0.56 eV and E{sub c} −0.61 eV in the interstitial-rich region of the self-implanted silicon, before any annealing. No DLTS signal originating from vacancy-oxygen trap at E{sub c} −0.17 eV, present in the sample irradiated with 0.8 MeV neutrons, has been recorded in the self-implanted sample.

  19. Comparison of single and mixed ion implantation effects on the changes of the surface hardness, light transmittance, and electrical conductivity of polymeric materials

    International Nuclear Information System (INIS)

    Park, J. W.; Lee, J. H.; Lee, J. S.; Kil, J. G.; Choi, B. H.; Han, Z. H.

    2001-01-01

    Single or mixed ions of N, He, C were implanted onto the transparent PET(Polyethylen Terephtalate) with the ion energies of less than 100 keV and the surface hardness, light transmittance and electrical conductivity were examined. As measured with nanoindentation, mixed ion implantations such as N + +He + or N + + C + exhibited more increase in the surface hardness than the single ion implantation. Especially, implantation of C+N ions increased the surface hardness by about three times as compared to the implantation of N ion alone, which means more than 10 times increase than the untreated PET. Surface electrical conductivity was increased along with the hardness increase. The conductivity increase was more proportional to the hardness when used the higher ion energy and ion dose, while it did not show any relationship at as low as 50 keV of ion energy. The light at the 550 nm wavelength (visual range) transmitted more than 85%, which is close to that of as-received PET, and at the wavelength below 300 nm(UV range) the rays were absorbed more than 95% as traveling through the sheet, implying that there are processing parameters which the ion implanted PET maintains the transparency and absorbs the UV rays

  20. Automated analysis of PET based in-vivo monitoring in ion beam therapy

    International Nuclear Information System (INIS)

    Kuess, P.

    2014-01-01

    Particle Therapy (PT)-PET is currently the only clinically approved in-vivo method for monitoring PT. Due to fragmentation processes in the patients' tissue and the beam projectiles, a beta plus activity distribution (BAD) can be measured during or shortly after the irradiation. The recorded activity map can not be directly compared to the planned dose distribution. However, by means of a Monte Carlo (MC) simulation it is possible to predict the measured BAD from a treatment plan (TP). Thus to verify a patient's treatment fraction the actual PET measurement can be compared to the respective BAD prediction. This comparison is currently performed by visual inspection which requires experienced evaluators and is rather time consuming. In this PhD thesis an evaluation tool is presented to compare BADs in an automated and objective way. The evaluation method was based on the Pearson's correlation coefficient (PCC) – an established measure in medical image processing – which was coded into a software tool. The patient data used to develop, test and validate the software tool were acquired at the GSI research facility where over 400 patient treatments with 12C were monitored by means of an in-beam PET prototype. The number of data sets was increased by artificially altering BAD to simulate different beam ranges. The automated detection tool was tested in head and neck (H&N), prostate, lung, and brain. To generate carbon ion TPs the treatment planning system TRiP98 was used for all cases. From these TPs the respective BAD predictions were derived. Besides the detection of range deviations by means of PT-PET also the automated detection of patient setup uncertainties was investigated. Although all measured patient data were recorded during the irradiation (in-beam) also scenarios performing PET scans shortly after the irradiation (in-room) were considered. To analyze the achievable precision of PT-PET with the automated evaluation tool based on

  1. Resonant pickups for non-destructive single-particle detection in heavy-ion storage rings and first experimental results

    Energy Technology Data Exchange (ETDEWEB)

    Sanjari, Mohammad Shahab

    2013-04-26

    Nuclear astrophysics studies on highly charged radionuclides benefit from accelerator facilities with storage rings, where exotic nuclides produced with small yields can be efficiently investigated. Currently there are two accelerator facilities capable of storing highly charged heavy ions, GSI in Darmstadt and IMP in Lanzhou. Non-destructive detection methods are often used for in-flight measurements based on frequency analysis. The sensitivity of such detection systems are of primary importance specially when number of stored ions is small. Furthermore, since the exotic nuclides of interest are as a rule short-lived, the detectors must be fast. One common form of such detectors are parallel plate SCHOTTKY monitors, on which particles induce a mirror charge at each passage. This method has been successfully used at ESR experimental storage ring of GSI since 1991. In this work we describe a new resonant SCHOTTKY pickup operating as a high sensitive cavity current monitor which was mounted and commissioned in the ESR early 2010. It was successfully used in several storage ring experiments. A very similar pickup was mounted in CSRe at IMP Lanzhou in 2011. First in-ring tests have been performed and new experimental results are pending. The spectral analysis of acquired signals by the new detector has enabled a broad range of new physics experiments. The theory of operation and first experimental results and future perspectives are presented in this thesis.

  2. Phase diagrams of the ternary alloy with a single-ion anisotropy in the mean-field approximation

    International Nuclear Information System (INIS)

    Dely, J.; Bobak, A.

    2006-01-01

    The phase diagram of the AB p C 1-p ternary alloy consisting of Ising spins S A =32, S B =2, and S C =52 is investigated by the use of a mean-field theory based on the Bogoliubov inequality for the Gibbs free energy. The effect of the single-ion anisotropy on the phase diagrams is discussed by changing values of the parameters in the model Hamiltonian and comparison is made with the recently reported finite-temperature phase diagrams for the ternary alloy having spin S B =1

  3. The influence of elastic subsystem on phase transitions in ferromagnets with competitive exchange and single-ion anisotropies

    International Nuclear Information System (INIS)

    Freedman, Yu.A.; Klevets, F.N.; Matunin, D.A.

    2006-01-01

    The influence of planar and bulk elastic interactions on the phase states of an ultrathin ferromagnetic film with anisotropic exchange interaction is investigated for different relationships among the material constants. It is shown that when the elastic interactions, with competing exchange and single-ion anisotropies, and the magnetic dipole interaction are taken into account, a cascade of phase transitions appears. Furthermore, taking the 'planar' elastic interaction into account leads to realization of an additional phase, with an easy axis in the film plane. This state is absent in the case of a bulk elastic subsystem

  4. A Distributed Monitoring and Control System for the Laser Ion Source RILIS at CERN-ISOLDE

    CERN Document Server

    AUTHOR|(SzGeCERN)715185; Richter, Detlef; Wendt, Klaus

    In this work, the implementation of the LabVIEW-based RILIS Equipment Acquisition and Control Toolset (REACT) software framework is documented, revised, and further developed to accomplish remotely operated in-source laser spectroscopy experiments at CERN-ISOLDE. The Resonance Ionization Laser Ion Source (RILIS) is an integral part of the radioactive ion beam user facility ISOLDE at CERN. Its task as an ion source is to ensure high isobaric purity and production efficiency of the ion beams that are generated for the various experimental setups of the facility. Reliable operation requires directing 3 pulsed laser beams, precisely wavelength-tuned and overlapped in time to a precision of 5 nanoseconds, to converge into a 3mm diameter ion source cavity located 25m away in an inaccessible radioactive environment. These stable conditions have to be maintained for up to 7 days at a time per experiment setup. Within recent years, the array of RILIS equipment and its need to interface with other experimental apparatu...

  5. Mesotubular-Structured Hybrid Membrane Nanocontainer for Periodical Monitoring, Separation, and Recovery of Cobalt Ions from Water.

    Science.gov (United States)

    El-Safty, Sherif A; Sakai, Masaru; Selim, Mahmoud M; Alhamid, Abdulaziz A

    2015-09-01

    Exposure to toxins can cause deleterious effects even at very low concentrations. We have developed an optical sensor, filter, and extractor (i.e., containerlike) in a nanoscale membrane (NSM) for the ultratrace sensing, separation, and recovery of Co(2+) ions from water. The design of the NSM is successfully controlled by dense decoration of a hydrophobic oil-hydrophilic receptor onto mesoscale tubular-structured silica nanochannels made of a hybrid anodic alumina membrane. The particular structure of the nanocontainer is ideal to control the multiple functions of the membrane, such as the optical detection/recognition, rejection/permeation, and recovery of Co(2+) species in a single step. A typical sensor, filter, and extractor assessment experiment was performed by using a benchtop contact time technique and a flow-through cell detector to allow for precise control of the optical detection and exclusive rejection of target ions and the permeation of nontarget metal ions in water. This nanocontainer membrane has great potential to meet the increasing needs of purification and separation of Co(2+) ions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. A self-calibrating ionisation chamber for the precise intensity calibration of high-energy heavy-ion beam monitors

    International Nuclear Information System (INIS)

    Junghans, A.

    1996-01-01

    The intensity of a 136 Xe(600 A MeV) beam has been determined by simultaneously measuring the particle rate and the corresponding ionisation current with an ionisation chamber. The ionisation current of this self-calibrating device was compared at higher intensities with the current of a secondary-electron monitor and a calibration of the secondary-electron current was achieved with a precision of 2%. This method can be applied to all high-energy heavy-ion beams. (orig.)

  7. Effects of Metal Ions on Conductivity and Structure of Single DNA Molecule in Different Environmental Conditions

    Directory of Open Access Journals (Sweden)

    Dong Ruixin

    2010-01-01

    Full Text Available Abstract We design a novel nano-gap electrode to measure the current of DNA molecule, by which the current–voltage characteristics of individual native DNA, Ag-DNA and Ni-DNA molecules are obtained, respectively. The results show that the voltage gap of Ag- and Ni-DNA is higher than that of native DNA, and the conductance is lower than native DNA in neutral environment. The structure transition from B- to Z-DNA is observed in the presence of high concentrations of nickel ions and Ag-DNA appears chaos state by STM image and U-V spectra characterization. But in alkaline environment, the conductance of Ni-DNA rises and the voltage gap decreases with the increasing of nickel ion concentration denotes that the conductive ability of Ni-DNA is higher than that of native DNA.

  8. Radiation damage induced in Al2O3 single crystal by 90 MeV Xe ions

    Science.gov (United States)

    Zirour, H.; Izerrouken, M.; Sari, A.

    2015-12-01

    Radiation damage induced in Al2O3 single crystal by 90 MeV Xe ions were investigated by optical absorption measurements, Raman spectroscopy and X-ray diffraction (XRD) techniques. The irradiations were performed at the GANIL accelerator in Caen, France for the fluence in the range from 1012 to 6 × 1013 cm-2 at room temperature under normal incidence. The F+ and F2+enters kinetic as a function of fluence deduced from the optical measurements explains that the single defects (F and F+) aggregate to F center clusters (F2 , F2+, F22+) during irradiation at high fluence (>1013 cm-2). Raman and XRD analysis reveal a partial disorder of 40% of Al2O3 in the studied fluence range in accordance with Kabir et al. (2008) study. The result suggests that this is due to the stress relaxation process which occurs at high fluence (>1013 cm-2).

  9. Hyperfine-Interaction-Driven Suppression of Quantum Tunneling at Zero Field in a Holmium(III) Single-Ion Magnet.

    Science.gov (United States)

    Chen, Yan-Cong; Liu, Jun-Liang; Wernsdorfer, Wolfgang; Liu, Dan; Chibotaru, Liviu F; Chen, Xiao-Ming; Tong, Ming-Liang

    2017-04-24

    An extremely rare non-Kramers holmium(III) single-ion magnet (SIM) is reported to be stabilized in the pentagonal-bipyramidal geometry by a phosphine oxide with a high energy barrier of 237(4) cm -1 . The suppression of the quantum tunneling of magnetization (QTM) at zero field and the hyperfine structures originating from field-induced QTMs can be observed even from the field-dependent alternating-current magnetic susceptibility in addition to single-crystal hysteresis loops. These dramatic dynamics were attributed to the combination of the favorable crystal-field environment and the hyperfine interactions arising from 165 Ho (I=7/2) with a natural abundance of 100 %. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Hyperfine-interaction-driven suppression of quantum tunneling at zero field in a holmium(III) single-ion magnet

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yan-Cong; Liu, Jun-Liang; Chen, Xiao-Ming; Tong, Ming-Liang [Key Lab. of Bioinorganic and Synthetic Chemistry of Ministry of Education, School of Chemistry, Sun Yat-Sen Univ., Guangzhou (China); Wernsdorfer, Wolfgang [Institut Neel, CNRS and Universite Joseph Fournier, Grenoble (France); Institute of Nanotechnology, Karlsruhe Institute of Technology (Germany); Physikalisches Institut, Karlsruhe Institute of Technology (Germany); Liu, Dan; Chibotaru, Liviu F. [Theory of Nanomaterials Group and INPAC-Institute of Nanoscale Physics and Chemistry, Katholieke Universiteit Leuven (Belgium)

    2017-04-24

    An extremely rare non-Kramers holmium(III) single-ion magnet (SIM) is reported to be stabilized in the pentagonal-bipyramidal geometry by a phosphine oxide with a high energy barrier of 237(4) cm{sup -1}. The suppression of the quantum tunneling of magnetization (QTM) at zero field and the hyperfine structures originating from field-induced QTMs can be observed even from the field-dependent alternating-current magnetic susceptibility in addition to single-crystal hysteresis loops. These dramatic dynamics were attributed to the combination of the favorable crystal-field environment and the hyperfine interactions arising from {sup 165}Ho (I=7/2) with a natural abundance of 100 %. (copyright 2017 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  11. Fabrication of single-crystal silicon nanotubes with sub-10 nm walls using cryogenic inductively coupled plasma reactive ion etching

    Science.gov (United States)

    Li, Zhiqin; Chen, Yiqin; Zhu, Xupeng; Zheng, Mengjie; Dong, Fengliang; Chen, Peipei; Xu, Lihua; Chu, Weiguo; Duan, Huigao

    2016-09-01

    Single-crystal silicon nanostructures have attracted much attention in recent years due in part to their unique optical properties. In this work, we demonstrate direct fabrication of single-crystal silicon nanotubes with sub-10 nm walls which show low reflectivity. The fabrication was based on a cryogenic inductively coupled plasma reactive ion etching process using high-resolution hydrogen silsesquioxane nanostructures as the hard mask. Two main etching parameters including substrate low-frequency power and SF6/O2 flow rate ratio were investigated to determine the etching mechanism in the process. With optimized etching parameters, high-aspect-ratio silicon nanotubes with smooth and vertical sub-10 nm walls were fabricated. Compared to commonly-used antireflection silicon nanopillars with the same feature size, the densely packed silicon nanotubes possessed a lower reflectivity, implying possible potential applications of silicon nanotubes in photovoltaics.

  12. Optical parameters and dispersion behavior of potassium magnesium chloride sulfate single crystals doped with Co+2 ions.

    Science.gov (United States)

    Abu El-Fadl, A; Abd-Elsalam, A M

    2018-05-05

    Single crystals of potassium magnesium chloride sulfate (KMCS) doped with cobalt ions were grown by slow cooling method. Powder XRD study confirmed the monoclinic structure of the grown crystals. The functional group vibrations were checked through FTIR spectroscopy measurements. In optical studies, the absorbance behavior of the crystals and their optical energy gap were established by Tauc plot. The refractive index, the extinction coefficient and other optical constants were calculated for the grown crystals. The normal dispersion of the refractive index was analyzed according to single oscillator Sellmeier's model. The Urbach's rule was applied to analyze the localized states density in the forbidden gap. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Trade study of leakage detection, monitoring, and mitigation technologies to support Hanford single-shell waste retrieval

    International Nuclear Information System (INIS)

    Hertzel, J.S.

    1996-03-01

    The U.S. Department of Energy has established the Tank Waste Remediation System to safely manage and dispose of low-level, high-level, and transuranic wastes currently stored in underground storage tanks at the Hanford Site in Eastern Washington. This report supports the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) Milestone No. M-45-08-T01 and addresses additional issues regarding single-shell tank leakage detection, monitoring, and mitigation technologies and provide an indication of the scope of leakage detection, monitoring, and mitigation activities necessary to support the Tank Waste Remedial System Initial Single-shell Tank Retrieval System project

  14. Surgical cardiac denervation therapy for treatment of congenital ion channelopathies in pediatric patients: a contemporary, single institutional experience.

    Science.gov (United States)

    Costello, John P; Wilson, Jennifer K; Louis, Clauden; Peer, Syed M; Zurakowski, David; Nadler, Evan P; Qureshi, Faisal G; Jonas, Richard A; Greene, E Anne; Berul, Charles I; Moak, Jeffrey P; Nath, Dilip S

    2015-01-01

    Congenital ion channel disorders, including congenital long QT syndrome (LQTS), cause significant morbidity in pediatric patients. When medication therapy does not control symptoms or arrhythmias, more invasive treatment strategies may be necessary. This study examines our institution's clinical experience with surgical cardiac denervation therapy for management of these arrhythmogenic disorders in children. An institutional review board-approved retrospective review identified ten pediatric patients with congenital ion channelopathies who underwent surgical cardiac denervation therapy at a single institution between May 2011 and April 2014. Eight patients had a diagnosis of congenital LQTS, two patients were diagnosed with catecholaminergic polymorphic ventricular tachycardia (CPVT). All patients underwent sympathectomy and partial stellate ganglionectomy via video-assisted thoracoscopic surgery (VATS). Six of the ten patients had documented ventricular arrhythmias preoperatively, and 70% of the patients had preoperative syncope. The corrected QT interval decreased in 75% of patients with LQTS following sympathectomy. Postoperative arrhythmogenic symptoms were absent in 88% of congenital LQTS patients, but both patients with CPVT continued to have symptoms throughout the duration of follow-up. All patients were alive after a median follow-up period of 10 months. Surgical cardiac denervation therapy via VATS is a useful treatment strategy for congenital LQTS patients who fail medical management, and its potential benefit in the management of CPVT is unclear. A prospective comparison of the efficacy of surgical cardiac denervation therapy and implantable cardioverter-defibrillator use in congenital ion channelopathies is timely and crucial. © The Author(s) 2014.

  15. Enzymatically mediated bioprecipitation of heavy metals from industrial wastes and single ion solutions by mammalian alkaline phosphatase.

    Science.gov (United States)

    Chaudhuri, Gouri; Shah, Gaurav A; Dey, Pritam; S, Ganesh; Venu-Babu, P; Thilagaraj, W Richard

    2013-01-01

    The study was aimed at investigating the potential use of calf intestinal alkaline phosphatase (CIAP) enzyme in the removal of heavy metals (Cd(2+), Ni(2+), Co(2+) and Cr(3+/6+)) from single ion solutions as well as tannery and electroplating effluents. CIAP mediated bioremediation (white biotechnology) is a novel technique that is eco-friendly and cost effective unlike the conventional chemical technologies. Typical reactions containing the enzyme (CIAP) and p-nitrophenyl phosphate (pNPP) as substrate in Tris-HCl buffer (pH 8 and 11) and either single ion metal solutions (250 ppm and 1000 ppm) or effluents from tannery or electroplating industry were incubated at 37°C for 30 min, 60 min and 120 min. The inorganic phosphate (P(i)) generated due to catalytic breakdown of pNPP complexes free metal ions as metal-phosphate and the amount of metal precipitated was derived by estimating the reduction in the free metal ion present in the supernatant of reactions employing atomic absorption spectrophotometer (AAS). Better precipitation of metal was obtained at pH 11 than at pH 8 and between the two concentrations of different metals tested, an initial metal concentration of 250 ppm in the reaction gave more precipitation than with 1000 ppm. Experimental data showed that at pH 11, the percentage of removal of metal ions (for an initial concentration of 250 ppm) was in the following order: Cd(2+) (80.99%) > Ni(2+) (64.78%) > Cr(3+) > (46.15%) > Co(2+) (36.47%) > Cr(6+) (32.33%). The overall removal of Cr(3+) and Cr(6+) from tannery effluent was 32.77% and 37.39% respectively in 120 min at pH 11. Likewise, the overall removal of Cd(2+), Co(2+) and Ni(2+) from electroplating effluent was 50.42%, 13.93% and 38.64% respectively in 120 min at pH 11. The study demonstrates that bioprecipitation by CIAP may be a viable and environmental friendly method for clean-up of heavy metals from tannery and electroplating effluents.

  16. Ambulatory urodynamic monitoring of women with overactive bladder syndrome during single voiding cycle.

    Science.gov (United States)

    Dokmeci, Fulya; Cetinkaya, S Esra; Seval, M Murat; Dai, Omer

    2017-05-01

    To present data of standardized ambulatory urodynamic monitoring (AUM) performed in women with overactive bladder syndrome (OAB) and to evaluate the relevance of AUM data with clinical findings of the patients. Records of women with symptoms of OAB were retrospectively reviewed (n=249). Of women fulfilling the Overactive Bladder Awareness Tool (OAB-V8) with a score ≥8 and the 3-day voiding diary (VD) with a frequency >7/day (n=167), those who underwent urodynamic investigation were selected (n=76). The data of this study were retrieved from the records of Ankara University Cebeci Hospital and based on the AUM findings of single voiding cycle of women with OAB. AUM, which is among the institutionally approved primary urodynamic investigation methods, is performed with LUNA ambulatory monitoring recorder (MMS™) in the clinical setting with a standardized technique, in reproducing lower urinary tract symptoms of women since 2011. The relationship of the urodynamic data with the clinical findings were evaluated. AUM traces of women (n=76) with OAB revealed 63.1% DO, 64.4% urgency and 77.7% urinary incontinence of which were 14.4% urgency urinary incontinence (UUI), 25% stress urinary incontinence (SUI) and 38.1% mixed urinary incontinence (MUI). OAB patients with DO reported more urinary incontinence episodes/day, nocturia and mixed urinary incontinence in the voiding diary (p<0.04) and had significantly higher irritative symptom bother reflected by the questionnaires (p<0.04). Women with DO were more likely to be postmenopausal (p=0.02) and were found to have more urgency (p<0.001), urgency episodes (p=0.05) and incontinence (urge and mixed) (p<0.001). However, no association was found between the extent of pelvic organ prolapse and the presence of DO. AUM performed with a standardized technique during single voiding cycle seems to be a reliable method in reproducing symptoms of women with OAB. It provides both clinically relevant findings and objective

  17. Phase precipitation of Yb 2+ ions in RbCl monocrystals monitored ...

    African Journals Online (AJOL)

    Optical absorption spectra of RbCl:Yb2+ crystals have been measured at several elevated temperatures up to 300C. Results showed that in hot RbCl:Yb2+ crystals, the Yb2+ ions occupied lattice sites with effective octahedral, O, point symmetry. Values of an energy parameter , which is an approximate measure of the ...

  18. Bunch-shape monitor for a picosecond single-bunch beam of a 35 MeV electron linear accelerator

    International Nuclear Information System (INIS)

    Hosono, Yoneichi; Nakazawa, Masaharu; Iguchi, Tetsuo

    1995-01-01

    A non-interactive-type bunch-shape and beam intensity monitor for a 35 MeV electron linear accelerator (linac) has been developed. The monitor consists of an electric SMA-type connector and an Al pipe of 50 mm inner diameter. Test measurements of the present monitor have been made under the conditions of the accelerated charges of lower than 27 nC/pulse and the pulse width ranging from 6 to 30 ps (Full Width at Half Maximum). The results show that the present monitor is applicable to bunch-shape measurement of the picosecond single-bunch beam. The monitor output is also found to be proportional to the beam intensity of more than 0.05 nC/pulse. (author)

  19. Deep reactive ion etching of fused silica using a single-coated soft mask layer for bio-analytical applications

    International Nuclear Information System (INIS)

    Ray, Tathagata; Zhu, Haixin; Meldrum, Deirdre R

    2010-01-01

    In this note, we present our results from process development and characterization of reactive ion etching (RIE) of fused silica using a single-coated soft masking layer (KMPR® 1025, Microchem Corporation, Newton, MA). The effects of a number of fluorine-radical-based gaseous chemistries, the gas flow rate, RF power and chamber pressure on the etch rate and etching selectivity of fused silica were studied using factorial experimental designs. RF power and pressure were found to be the most important factors in determining the etch rate. The highest fused silica etch rate obtained was about 933 Å min −1 by using SF 6 -based gas chemistry, and the highest etching selectivity between the fused silica and KMPR® 1025 was up to 1.2 using a combination of CF 4 , CHF 3 and Ar. Up to 30 µm deep microstructures have been successfully fabricated using the developed processes. The average area roughness (R a ) of the etched surface was measured and results showed it is comparable to the roughness obtained using a wet etching technique. Additionally, near-vertical sidewalls (with a taper angle up to 85°) have been obtained for the etched microstructures. The processes developed here can be applied to any application requiring fabrication of deep microstructures in fused silica with near-vertical sidewalls. To our knowledge, this is the first note on deep RIE of fused silica using a single-coated KMPR® 1025 masking layer and a non-ICP-based reactive ion etcher. (technical note)

  20. The structural and compositional analysis of single crystal surfaces using low energy ion scattering

    International Nuclear Information System (INIS)

    Armour, D.G.; Van der Berg, J.A.; Verheij, IL.K.

    1979-01-01

    The use of ion scattering for surface composition and structure analysis has been reviewed. The extreme surface specificity of this technique has been widely used to obtain quitative information in a straightforward way, but the/aolc/currence of charge exchange processes, thermal lattice vibrations and multiple scattering have precluded quantitative analysis of experimental data. Examples are quoted to illustrate the progress that has been made in understanding these fundamental processes and in applying this knowledge to the development of the analytical capabilities of the technique. (author)

  1. Developing on-site paper colorimetric monitoring technique for quick evaluating copper ion concentration in mineral wastewater

    Science.gov (United States)

    Liu, Guokun; Peng, Jingji; Zheng, Hong; Yuan, Dongxing

    2018-05-01

    With the reinforce of the copper mining, the on-site monitoring of the accompanied effluent discharge is highly demanded for the emergency response to minimize the negative effect of the effluent on the surrounding ecosystem. On the basis of the specific interaction between Cu2+ and L-Cysteine (L-Cys), which was modified on gold nanoparticles (Au NPs), and the aggregation dependent surface plasmon resonance (SPR) of Au NPs, we developed an easy-on-going paper colorimetric method for the quick evaluating the copper ion concentration in the waste water excreted from the copper mine. The color change of L-Cys modified Au NPs (L-Cys-Au NPs)immobilized on a filter paper was very sensitive to the Cu2+ concentration and free of interference from other metal ions typically in waste water. The proposed paper colorimetry has the LOD of 0.09 mg/L and the linear range of 0.1-10 mg/L, respectively, with the RSD (n = 5) was 6.6% for 1 mg/L Cu2+ and 3.5% for 5 mg/L Cu2+. The quantitative analysis results for the mineral wastewater is in good agreement the China National Environmental Protection Standards HJ485-2009, which indicates the current method could be developed to the on-site detection technique for the emergency response in monitoring Cu2+ in industrial wastewater or polluted water.

  2. Giant plasmon excitation in single and double ionization of C60 by fast highly charged Si and O ions

    Science.gov (United States)

    Kelkar, A. H.; Kadhane, U.; Misra, D.; Tribedi, L. C.

    2007-09-01

    Se have investigated single and double ionization of C60 molecule in collisions with 2.33 MeV/u Siq+ (q=6-14) and 3.125 MeV/u Oq+ (q=5-8) projectiles. The projectile charge state dependence of the single and double ionization yields of C60 are then compared to those for an ion-atom collision system using Ne gas as a target. A large difference between the gas and the cluster target behaviour was partially explained in terms of a model based on collective excitation namely the giant dipole plasmon resonance (GDPR). The qualitative agreement between the data and GDPR model prediction for single and double ionization signifies the importance of single and double plasmon excitations in the ionization process. A large deviation of the GDPR model for triple and quadruple ionization from the experimental data imply the importance of the other low impact parameter processes such as evaporation, fragmentation and a possible solid-like dynamical screening.

  3. Giant plasmon excitation in single and double ionization of C60 by fast highly charged Si and O ions

    International Nuclear Information System (INIS)

    Kelkar, A H; Kadhane, U; Misra, D; Tribedi, L C

    2007-01-01

    Se have investigated single and double ionization of C 60 molecule in collisions with 2.33 MeV/u Si q+ (q=6-14) and 3.125 MeV/u O q+ (q=5-8) projectiles. The projectile charge state dependence of the single and double ionization yields of C 60 are then compared to those for an ion-atom collision system using Ne gas as a target. A large difference between the gas and the cluster target behaviour was partially explained in terms of a model based on collective excitation namely the giant dipole plasmon resonance (GDPR). The qualitative agreement between the data and GDPR model prediction for single and double ionization signifies the importance of single and double plasmon excitations in the ionization process. A large deviation of the GDPR model for triple and quadruple ionization from the experimental data imply the importance of the other low impact parameter processes such as evaporation, fragmentation and a possible solid-like dynamical screening

  4. Supramolecular Nanoparticles via Single-Chain Folding Driven by Ferrous Ions.

    Science.gov (United States)

    Wang, Fei; Pu, Hongting; Jin, Ming; Wan, Decheng

    2016-02-01

    Single-chain nanoparticles can be obtained via single-chain folding assisted by intramolecular crosslinking reversibly or irreversibly. Single-chain folding is also an efficient route to simulate biomacromolecules. In present study, poly(N-hydroxyethylacrylamide-co-4'-(propoxy urethane ethyl acrylate)-2,2':6',2''-terpyridine) (P(HEAm-co-EMA-Tpy)) is synthesized via reversible addition fragmentation chain transfer polymerization. Single-chain folding and intramolecular crosslinking of P(HEAm-co-EMA-Tpy) are achieved via metal coordination chemistry. The intramolecular interaction is characterized on ultraviolet/visible spectrophotometer (UV-vis spectroscopy), proton nuclear magnetic resonance ((1)H NMR), and differential scanning calorimetry (DSC). The supramolecular crosslinking mediated by Fe(2+) plays an important role in the intramolecular collapsing of the single-chain and the formation of the nanoparticles. The size and morphology of the nanoparticles can be controlled reversibly via metal coordination chemistry, which can be characterized by dynamic light scattering (DLS), transmission electron microscope (TEM), and atomic force microscope (AFM). © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Real-time monitoring and manipulation of single bio-molecules in free solution

    Energy Technology Data Exchange (ETDEWEB)

    Li, Hung-Wing [Iowa State Univ., Ames, IA (United States)

    2005-01-01

    The observation and manipulation of single biomolecules allow their dynamic behaviors to be studied to provide insight into molecular genetics, biochip assembly, biosensor design, DNA biophysics. In a PDMS/glass microchannel, a nonuniform electroosmotic flow (EOF) was created. By using a scanning confocal fluorescence microscope and total internal-reflection fluorescence microscope (TIRFM), we demonstrated that negatively charged DNA molecules were focused by the nonuniform EOF into a thin layer at the glass surface. This phenomenon was applied to selectively detect target DNA molecules without requiring the separation of excessive probes and can be applied continuously to achieve high throughput. A variable-angle-TIRFM was constructed for imaging single DNA molecule dynamics at a solid/liquid interface. Implications we have are that the measured intensities cannot be used directly to determine the distances of molecules from the surface and the experimental counting results depict the distance-dependent dynamics of molecules near the surface; Molecules at low ionic strengths experience electrostatic repulsion at distances much further away from the surface than the calculated thickness of the electrical double layer. {delta}-DNA was employed as a nanoprobe for different functionalized surfaces to elucidate adsorption in chromatography. The 12-base unpaired ends of this DNA provide exposed purine and pyrimidine groups for adsorption. Patterns of self-assembled monolayers (SAMs) and patterns of metal oxides are generated. By recording the real-time dynamic motion of DNA molecules at the SAMs/aqueous interface, the various parameters governing the retention of an analyte during chromatographic separation can be studied. Even subtle differences among adsorptive forces can be revealed. Dynamic conformational changes of the prosthetic group, flavin adenine dinucleotide (FAD), in flavoprotein NADH peroxidase, in thioredoxin reductase, and in free solution were monitored

  6. Comparison of direct sampling ion trap mass spectrometry to GC/MS for monitoring VOCs in groundwater

    International Nuclear Information System (INIS)

    Wise, M.B.; Merriweather, R.; Guerin, M.; Thompson, C.V.

    1995-01-01

    Rapid analytical methods which utilize Direct Sampling Ion Trap Mass Spectrometry for field screening and compliance monitoring of volatile organic compounds in groundwater have been under development in this laboratory for several years. These methods can be used on fieldable instrumentation, have low ppb detection limits, and require little or no sample preparation. The DSITMS analysis of VOCs in water uses a three minute direct purge of the water sample with a stream of helium at a flow rate of 100 mL/min. VOCs partition into the helium stream and are carried directly into the ion trap via a 100 um section of fused silica capillary. Most of the sample is vented through an open/split interface, with only about 1 mL/min. entering the mass spectrometer. Analysis of the VOCs is accomplished by alternating conditions in the ion trap at roughly one second intervals between electron ionization and chemical ionization (water reagent gas). Two such methods for the analysis of VOCs in water have been submitted to EPA for regulatory approval, and in order to facilitate this process, validation studies have been conducted comparing the DSITMS method to a standard method such as purge-and-trap GC/MS. One such study, recently completed, involved the analysis of over 100 groundwater samples collected from the Oak Ridge reservation for compliance monitoring. Split samples of the groundwater were analyzed by DSITMS and by purge-and-trap GC/MS at a local CLP laboratory. The results of the comparative study generally show excellent qualitative and quantitative agreement between the DSITMS and standard methods, with the DSITMS method being superior with respect to speed, cost, ease of use, and minimized artifacts

  7. Heavy Ion Irradiation Fluence Dependence for Single-Event Upsets in a NAND Flash Memory

    Science.gov (United States)

    Chen, Dakai; Wilcox, Edward; Ladbury, Raymond L.; Kim, Hak; Phan, Anthony; Seidleck, Christina; Label, Kenneth

    2016-01-01

    We investigated the single-event effect (SEE) susceptibility of the Micron 16 nm NAND flash, and found that the single-event upset (SEU) cross section varied inversely with cumulative fluence. We attribute the effect to the variable upset sensitivities of the memory cells. Furthermore, the effect impacts only single cell upsets in general. The rate of multiple-bit upsets remained relatively constant with fluence. The current test standards and procedures assume that SEU follow a Poisson process and do not take into account the variability in the error rate with fluence. Therefore, traditional SEE testing techniques may underestimate the on-orbit event rate for a device with variable upset sensitivity.

  8. Microstructural evolution of reduced-activation martensitic steel under single and sequential ion irradiations

    International Nuclear Information System (INIS)

    Luo, Fengfeng; Guo, Liping; Jin, Shuoxue; Li, Tiecheng; Zheng, Zhongcheng; Yang, Feng; Xiong, Xuesong; Suo, Jinping

    2013-01-01

    Microstructural evolution of super-clean reduced-activation martensitic steels irradiated with single-beam (Fe + ) and sequential-beam (Fe + plus He + ) at 350 °C and 550 °C was studied. Sequential-beam irradiation induced smaller size and larger number density of precipitates compared to single-beam irradiation at 350 °C. The largest size of cavities was observed after sequential-beam irradiation at 550 °C. The segregation of Cr and W and depletion of Fe in carbides were observed, and the maximum depletion of Fe and enrichment of Cr occurred under irradiation at 350 °C

  9. Single-walled carbon nanotubes as stabilizing agents in red phosphorus Li-ion battery anodes

    KAUST Repository

    Smajic, Jasmin

    2017-08-16

    Phosphorus boasts extremely high gravimetric and volumetric capacities but suffers from poor electrochemical stability with significant capacity loss immediately after the first cycle. We propose to circumvent this issue by mixing amorphous red phosphorus with single-walled carbon nanotubes. Employing a non-destructive sublimation–deposition method, we have synthesized composites where the synergetic effect between red phosphorus and single-walled carbon nanotubes allows for a considerable improvement in the electrochemical stability of battery anodes. In contrast to the average 40% loss of capacity after 50 cycles for other phosphorus–carbon composites in the literature, our material shows losses of just 22% under analogous cycling conditions.

  10. What Factors Coordinate the Optimal Position of a Single Monitoring Well Down Gradient of a Hazardous Site?

    Science.gov (United States)

    Bode, F.; Nowak, W.

    2013-12-01

    Drinking-water well catchments include many sources for potential contaminations like gas stations, roads, or fields used for agriculture. Additionally, there are many contaminated sites that need to be monitored inside and outside drinking water catchments. Finding optimal positions of monitoring wells for such purposes is challenging because there are various parameters (and their uncertainties) that influence the reliability and optimality of a suggested monitoring location. For example, there may be uncertainty in the exact position of the contamination, in the source volume, in the direction of the velocity field which can vary in angle and absolute value, and in other parameters that describe, e.g., dispersion and decay. Many national regulations and UN guidelines suggest monitoring as measure of risk control, but make no statements how to asses or design monitoring under the fact of uncertainty. To obtain optimal positions of monitoring wells, a large body of recent studies uses formal optimization approaches. Our goal is to obtain a better system understanding at a fundamental process level for the one-on-one situation of a single monitoring well for a single monitoring target. This knowledge can be used for a better understanding of the optimization results in complex situations, and also to better guide and restrict optimization procedures by newly obtained export knowledge. In order to obtain fundamental statements regardless of specific simulation settings, we use an analytical model based on the 2D steady-state advection-dispersion equation to predict contaminant transport from the monitoring target. Monte Carlo simulation techniques are applied to represent parametric uncertainty. Thus, we can obtain maps of contaminant detection probability for all possible placements of the monitoring well. The optimal position is defined by the highest detection probability. First findings show that uncertainty in the spill location pushes the optimal monitoring

  11. Formation of oriented nitrides by N{sup +} ion implantation in iron single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Costa, A.R.G. [CFMC, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Silva, R.C. da [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Ferreira, L.P. [CFMC, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Dep. Física, Fac. Ciências e Tecnologia, Universidade de Coimbra, 3004-516 Coimbra (Portugal); Carvalho, M.D. [CCMM/Dep. Química e Bioquímica, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Silva, C. [CFMC, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Dep. Física, Fac. Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Franco, N. [IST/IPFN, Universidade de Lisboa, Campus Tecnológico e Nuclear, E.N.10, 2686-953 Sacavém (Portugal); Godinho, M. [CFMC, Faculdade de Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); Dep. Física, Fac. Ciências, Universidade de Lisboa, Campo Grande, 1749-016 Lisboa (Portugal); and others

    2014-01-15

    Iron single crystals were implanted with nitrogen at room temperature, with a fluence of 5×10{sup 17} cm{sup −2} and 50 keV energy, to produce iron nitride phases and characterize the influence of the crystal orientation. The stability and evolution of the nitride phases and diffusion of implanted nitrogen were studied as a function of successive annealing treatments at 250 °C in vacuum. The composition, structure and magnetic properties were characterized using RBS/channeling, X-Ray Diffraction, Magnetic Force Microscopy, Magneto-optical Kerr Effect and Conversion Electron Mössbauer Spectroscopy. In the as-implanted state the formation of Fe{sub 2}N phase was clearly identified in all single crystals. This phase is not stable at 250 °C and annealing at this temperature promotes the formation of ε-Fe{sub 3}N, or γ′-Fe{sub 4}N, depending on the orientation of the substrate. - Highlights: • Oriented magnetic iron nitrides were obtained by nitrogen implantation into iron single crystals. • The stable magnetic nitride phase at 250 °C depends on the orientation of the host single crystal, being γ'-Fe{sub 4}N or ε-Fe{sub 3}N. • The easy magnetization axis was found to lay in the (100) plane for cubic γ'-Fe{sub 4}N and out of (100) plane for hexagonal ε-Fe{sub 3}N.

  12. High-energy heavy ion testing of VLSI devices for single event ...

    Indian Academy of Sciences (India)

    Unknown

    Single event upset is defined by NASA as 'radiation- induced errors in microelectronic circuits caused when charged particles (usually from the radiation belts or from cosmic rays) lose energy by ionizing the medium through which they pass, leaving behind a wake of elec- tron-hole pairs'. SEU are transient soft errors and ...

  13. Formation of oriented nitrides by N+ ion implantation in iron single crystals

    International Nuclear Information System (INIS)

    Costa, A.R.G.; Silva, R.C. da; Ferreira, L.P.; Carvalho, M.D.; Silva, C.; Franco, N.; Godinho, M.

    2014-01-01

    Iron single crystals were implanted with nitrogen at room temperature, with a fluence of 5×10 17 cm −2 and 50 keV energy, to produce iron nitride phases and characterize the influence of the crystal orientation. The stability and evolution of the nitride phases and diffusion of implanted nitrogen were studied as a function of successive annealing treatments at 250 °C in vacuum. The composition, structure and magnetic properties were characterized using RBS/channeling, X-Ray Diffraction, Magnetic Force Microscopy, Magneto-optical Kerr Effect and Conversion Electron Mössbauer Spectroscopy. In the as-implanted state the formation of Fe 2 N phase was clearly identified in all single crystals. This phase is not stable at 250 °C and annealing at this temperature promotes the formation of ε-Fe 3 N, or γ′-Fe 4 N, depending on the orientation of the substrate. - Highlights: • Oriented magnetic iron nitrides were obtained by nitrogen implantation into iron single crystals. • The stable magnetic nitride phase at 250 °C depends on the orientation of the host single crystal, being γ'-Fe 4 N or ε-Fe 3 N. • The easy magnetization axis was found to lay in the (100) plane for cubic γ'-Fe 4 N and out of (100) plane for hexagonal ε-Fe 3 N

  14. A low-cost non-intercepting beam current and phase monitor for heavy ions

    International Nuclear Information System (INIS)

    Bogaty, J.M.; Clifft, B.E.

    1995-01-01

    A low cost ion beam measurement system has been developed for use at ATLAS. The system provides nondestructive phase and intensity measurement of passing ion beam bunches by sensing their electric fields. Bunches traverse a short tubular electrode thereby inducing displacement currents. These currents are brought outside the vacuum jacket where a lumped inductance resonates electrode capacitance at one of the bunching harmonic frequencies. This configuration yields a basic sensitivity of a few hundred millivolts signal per microampere of beam current. Beam induced radiofrequency signals are summed against an offset frequency generated by the master oscillator. The resulting difference frequency conveys beam intensity and bunch phase information which is sent to separate processing channels. One channel utilizes a phase locked loop to stabilize phase readings during microsecond beam drop outs. The other channel uses a linear full-wave active rectifier circuit which converts sine wave signal amplitude to a DC voltage representing beam current. Plans are in progress to install this new diagnostic at several locations in ATLAS which should help shorten the tuning cycle of new ion species

  15. A Single-Subject Study of a Technology-Based Self-Monitoring Intervention

    Science.gov (United States)

    Vogelgesang, Kari L.; Bruhn, Allison L.; Coghill-Behrends, William L.; Kern, Amanda M.; Troughton, Leonard C. W.

    2016-01-01

    Students with ADHD often struggle with self-regulation skills. One strategy demonstrating considerable success in helping these students regulate their behavior is self-monitoring. Although there is an abundance of research on self-monitoring, research on the use of technology for self-monitoring is only beginning to emerge. The primary goal of…

  16. Electrical properties of InP:Fe single crystals implanted by phosphorus ions

    International Nuclear Information System (INIS)

    Radautsan, S.I.; Tiginyanu, I.M.; Pyshnaya, N.B.

    1988-01-01

    Investigations of phosphorus ion implantation in InP:Fe monocrystals and of the post-implantation annealing process upon the electrical properties of InP:Fe were carried out. The electrical parameters of the samples have been determined by Hall effect measurements. The curves of electron surface concentration n s and mobility μ s as functions of annealing temperature in the range of 200 to 600 0 C are shown and discussed. In order to estimate the depth of donor levels in annealed samples the temperature dependence of the surface Hall coefficient has been studied in the range 100 to 400 K. The thermal electron activation energy has been determined to be 0.09 eV

  17. Monte Carlo prediction of crater formation by single ion impact on solid surface

    International Nuclear Information System (INIS)

    Perez-Martin, A.M.C.; Dominguez-Vazquez, J.; Jimenez-Rodriguez, J.J.; Collins, R.; Gras-Marti, A.

    1994-01-01

    A method is presented for predicting the topography changes following the impact of one energetic ion on the plane surface of a monatomic amorphous solid. This is done in two stages. The first is a Monte Carlo calculation of the sputter yield and interior distribution relocated atoms, with no compensation for local departures from equilibrium density. In the second stage there is a systematic relaxation of the solid, in which the density returns to its previous constant value and a crater develops in the surface. Two alternative methods of carrying out stage two are compared. In the first the solid is subdivided into cells within which relaxation is carried out normal to the surface, as in previous one-dimensional studies. The second method treats the solid as a 3-dimensional incompressible medium. Both seem to reproduce quite well the main features found experimentally. (orig.)

  18. Microstructural evolution of reduced-activation martensitic steel under single and sequential ion irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Fengfeng [Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, Hubei Nuclear Solid Physics Key Laboratory and School of Physics and Technology, Wuhan University, Wuhan 430072 (China); Guo, Liping, E-mail: guolp@whu.edu.cn [Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, Hubei Nuclear Solid Physics Key Laboratory and School of Physics and Technology, Wuhan University, Wuhan 430072 (China); Jin, Shuoxue; Li, Tiecheng; Zheng, Zhongcheng [Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, Hubei Nuclear Solid Physics Key Laboratory and School of Physics and Technology, Wuhan University, Wuhan 430072 (China); Yang, Feng; Xiong, Xuesong; Suo, Jinping [State Key Laboratory of Mould Technology, Institute of Materials Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074 (China)

    2013-07-15

    Microstructural evolution of super-clean reduced-activation martensitic steels irradiated with single-beam (Fe{sup +}) and sequential-beam (Fe{sup +} plus He{sup +}) at 350 °C and 550 °C was studied. Sequential-beam irradiation induced smaller size and larger number density of precipitates compared to single-beam irradiation at 350 °C. The largest size of cavities was observed after sequential-beam irradiation at 550 °C. The segregation of Cr and W and depletion of Fe in carbides were observed, and the maximum depletion of Fe and enrichment of Cr occurred under irradiation at 350 °C.

  19. Ion mobility spectrometry as a simple and rapid method to measure the plasma propofol concentrations for intravenous anaesthesia monitoring

    Science.gov (United States)

    Wang, Xin; Zhou, Qinghua; Jiang, Dandan; Gong, Yulei; Li, Enyou; Li, Haiyang

    2016-11-01

    The plasma propofol concentration is important information for anaesthetists to monitor and adjust the anaesthesia depth for patients during a surgery operation. In this paper, a stand-alone ion mobility spectrometer (IMS) was constructed for the rapid measurement of the plasma propofol concentrations. Without any sample pre-treatment, the plasma samples were dropped on a piece of glass microfiber paper and then introduced into the IMS cell by the thermal desorption directly. Each individual measurement could be accomplished within 1 min. For the plasma propofol concentrations from 1 to 12 μg mL-1, the IMS response was linear with a correlation coefficient R2 of 0.998, while the limit of detection was evaluated to be 0.1 μg mL-1. These measurement results did meet the clinical application requirements. Furthermore, other clinically-often-used drugs, including remifentanil, flurbiprofen and atracurium, were found no significant interference with the qualitative and quantitative analysis of the plasma propofol. The plasma propofol concentrations measured by IMS were correlated well with those measured by the high performance liquid chromatography (HPLC). The results confirmed an excellent agreement between these two methods. Finally, this method was applied to monitor the plasma propofol concentrations for a patient undergoing surgery, demonstrating its capability of anaesthesia monitoring in real clinical environments.

  20. Continuous on-line hydrogen ion monitoring to study flow dynamics of perifusion systems and cellular metabolism.

    Science.gov (United States)

    Brand, R M; Ghazzi, M N; Rolfes-Curl, A; Cantor, H C; Midgley, A R

    1994-05-01

    Time-dependent concentration profiles of input signals and feedback of metabolic products can strongly influence cellular responsiveness. To study these parameters, we developed a perifusion system that can deliver biological signals to cells with minimal dispersion, monitor real time responses, and remove waste products continuously. By monitoring pH with miniature hydrogen ion-selective electrodes at intervals of 1 s, effects of dispersion, flow rate, pumping system, and changes in cellular metabolism were demonstrated. Dynamic responses of a human cell line to a series of 10-min pulses of the metabolic uncoupler carbonyl cyanide m-chlorophenylhydrazone (CCCP) were monitored. A rapid 1-min increase in acid release occurred on exposure to CCCP, followed by a decrease in acidification and then a gradual return to a baseline slightly more acidic than before administration of CCCP. These observations demonstrate that this perifusion system can reveal small changes in pH (+/- 0.0005 units) induced by metabolic perturbations and has the potential to reveal the dynamics of cellular responsiveness to a wide range of hormonal, metabolic, and other chemical signals.

  1. Focused-ion-beam overlay-patterning of three-dimensional diamond structures for advanced single-photon properties

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Qianqing; Liu, Dongqi; Liu, Gangqin; Chang, Yanchun; Li, Wuxia, E-mail: liwuxia@aphy.iphy.ac.cn, E-mail: czgu@aphy.iphy.ac.cn [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Pan, Xinyu; Gu, Changzhi, E-mail: liwuxia@aphy.iphy.ac.cn, E-mail: czgu@aphy.iphy.ac.cn [Beijing National Laboratory of Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190 (China); Collaborative Innovation Center of Quantum Matter, Beijing 100190 (China)

    2014-07-28

    Sources of single photons are of fundamental importance in many applications as to provide quantum states for quantum communication and quantum information processing. Color centers in diamond are prominent candidates to generate and manipulate quantum states of light, even at room temperature. However, the efficiency of photon collection of the color centers in bulk diamond is greatly reduced by refraction at the diamond/air interface. To address this issue, diamond structuring has been investigated by various methods. Among them, focused-ion-beam (FIB) direct patterning has been recognized as the most favorable technique. But it has been noted that diamond tends to present significant challenges in FIB milling, e.g., the susceptibility of forming charging related artifacts and topographical features. In this work, periodically-positioned-rings and overlay patterning with stagger-superimposed-rings were proposed to alleviate some problems encountered in FIB milling of diamond, for improved surface morphology and shape control. Cross-scale network and uniform nanostructure arrays have been achieved in single crystalline diamond substrates. High quality diamond solid immersion lens and nanopillars were sculptured with a nitrogen-vacancy center buried at the desired position. Compared with the film counterpart, an enhancement of about ten folds in single photon collection efficiency was achieved with greatly improved signal to noise ratio. All these results indicate that FIB milling through over-lay patterning could be an effective approach to fabricate diamond structures, potentially for quantum information studies.

  2. Multi-wire chamber system for heavy ion beam monitoring at the Bevalac

    International Nuclear Information System (INIS)

    Cuperus, J.; Morgado, R.

    1975-03-01

    Horizontal and vertical integrated beam-current profiles are generated by a system of multi-wire chambers (32 wires/profile) operating in either the ionization or proportional mode. Sixteen distinct displays (1024 words) are digitally stored and any four may be simultaneously displayed. A new display can be generated at 64 ms intervals. A central control unit selects the mode of operation, the amount of delay after an appropriate trigger, the chamber integration time, and the particular chambers to be displayed. Operating in the proportional mode, the system can detect relativistic heavy-ion beam intensities as low as 10 4 charges cm -2 sec -1 . (U.S.)

  3. Absence of single critical dose for the amorphization of quartz under ion irradiation

    Science.gov (United States)

    Zhang, S.; Pakarinen, O. H.; Backholm, M.; Djurabekova, F.; Nordlund, K.; Keinonen, J.; Wang, T. S.

    2018-01-01

    In this work, we first simulated the amorphization of crystalline quartz under 50 keV 23 Na ion irradiation with classical molecular dynamics (MD). We then used binary collision approximation algorithms to simulate the Rutherford backscattering spectrometry in channeling conditions (RBS-C) from these irradiated MD cells, and compared the RBS-C spectra with experiments. The simulated RBS-C results show an agreement with experiments in the evolution of amorphization as a function of dose, showing what appears to be (by this measure) full amorphization at about 2.2 eVṡatom-1 . We also applied other analysis methods, such as angular structure factor, Wigner–Seitz, coordination analysis and topological analysis, to analyze the structural evolution of the irradiated MD cells. The results show that the atomic-level structure of the sample keeps evolving after the RBS signal has saturated, until the dose of about 5 eVṡatom-1 . The continued evolution of the SiO2 structure makes the definition of what is, on the atomic level, an amorphized quartz ambiguous.

  4. Charge transport and glassy dynamics of poly(ethylene oxide)-based single-ion conductors under geometrical confinement

    Science.gov (United States)

    Runt, James; Iacob, Ciprian

    2015-03-01

    Segmental and local dynamics as well as charge transport are investigated in a series of poly(ethylene oxide)-based single-ion conductors (ionomers) with varying counterions (Li +, Na +) confined in uni-directional nanoporous silica membranes. The dynamics are explored over a wide frequency and temperature range by broadband dielectric relaxation spectroscopy. Slowing of segmental dynamics and a decrease in dc conductivity (strongly coupled with segmental relaxation) of the confined ionomers are associated with surface effects - resulting from interfacial hydrogen bonding between the host nanoporous silica membrane and the guest ionomers. These effects are significantly reduced or eliminated upon pore surface modification through silanization. The primary transport properties for the confined ionomers decrease by about one decade compared to the bulk ionomer. A model assuming reduced mobility of an adsorbed layer at the pore wall/ionomer interface is shown to provide a quantitative explanation for the decrease in effective transport quantities in non-silanized porous silica membranes. Additionally, the effect of confinement on ion aggregation in ionomers by using X-ray scattering will also be discussed. Supported by the National Science Foundation, Polymers Program.

  5. Calculations of Q values in single- and double-charge-transfer collisions of highly charged ions with atoms

    International Nuclear Information System (INIS)

    Chen, Z.; Lin, C.D.; Toshima, N.

    1994-01-01

    Close-coupling calculations are carried out for the Q values for electron capture processes in collisions of multiply charged ions with atoms over a broad range of energies. For single-capture processes the results for N 7+ +He and O 8+ +He collisions are in good agreement with the experimental data of Wu et al. [preceding paper, Phys. Rev. A 50, 502 (1994)]. To compare with the experimental Q values for the transfer ionization (TI) and the true double-capture (TDC) processes, an independent-electron model was used to calculate double-electron-capture cross sections. By combining with the calculated average fluorescence yields, the theoretical Q values for TI and TDC processes are also found to be in fair agreement with the experimental data. We also compared the Q values calculated by the close-coupling method and by the classical-trajectory Monte Carlo method

  6. Upconversion study of singly activator ions doped La2O3 nanoparticle synthesized via optimized solvothermal method

    Science.gov (United States)

    Tiwari, S. P.; Singh, S.; Kumar, A.; Kumar, K.

    2016-05-01

    In present work, an optimized solvothermal method has been chosen to synthesize the singly doped Er3+ activator ions with La2O3 host matrix. The sample is annealed at 500 °C in order to remove the moisture and other organic impurities. The sample is characterized by using XRD and FESEM to find out the phase and surface morphology. The observed particle size is found almost 80 nm with spherical agglomerated shape. Upconversion spectra are recorded at room temperature using 976 nm diode laser excitation sources and consequently the emission peaks in green and red region are observed. The color coordinate diagram shows the results that the present material may be applicable in different light emitting sources.

  7. A novel sensor for monitoring of iron(III) ions based on porphyrins.

    Science.gov (United States)

    Vlascici, Dana; Fagadar-Cosma, Eugenia; Popa, Iuliana; Chiriac, Vlad; Gil-Agusti, Mayte

    2012-01-01

    Three A(3)B porphyrins with mixed carboxy-, phenoxy-, pyridyl-, and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10(-7)-1 × 10(-1) M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples.

  8. A Novel Sensor for Monitoring of Iron(III) Ions Based on Porphyrins

    Science.gov (United States)

    Vlascici, Dana; Fagadar-Cosma, Eugenia; Popa, Iuliana; Chiriac, Vlad; Gil-Agusti, Mayte

    2012-01-01

    Three A3B porphyrins with mixed carboxy-, phenoxy-, pyridyl-, and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III). The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore). The performance characteristics (linear concentration range, slope and selectivity) of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl)-10,15,20-tris(4-phenoxyphenyl)-porphyrin plasticized with bis(2-ethylhexyl)sebacate, in a linear range from 1 × 10−7–1 × 10−1 M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III) in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III) in tap water samples. PMID:22969395

  9. A Novel Sensor for Monitoring of Iron(III Ions Based on Porphyrins

    Directory of Open Access Journals (Sweden)

    Mayte Gil-Agusti

    2012-06-01

    Full Text Available Three A3B porphyrins with mixed carboxy-, phenoxy-, pyridyl- and dimethoxy-substituent functionalization on the meso-phenyl groups were obtained by multicomponent synthesis, fully characterized and used as ionophores for preparing PVC-based membrane sensors selective to iron(III. The membranes have an ionophore:PVC:plasticizer composition ratio of 1:33:66. Sodium tetraphenylborate was used as additive (20 mol% relative to ionophore. The performance characteristics (linear concentration range, slope and selectivity of the sensors were investigated. The best results were obtained for the membrane based on 5-(4-carboxyphenyl-10,15,20-tris(4-phenoxyphenyl-porphyrin plasticized with bis(2-ethylhexylsebacate, in a linear range from 1 × 10−7–1 × 10−1 M with a slope of 21.6 mV/decade. The electrode showed high selectivity with respect to alkaline and heavy metal ions and a response time of 20 s. The influence of pH on the sensor response was studied. The sensor was used for a period of six weeks and the utility has been tested for the quantitative determination of Fe(III in recovered solutions from spent lithium ion batteries and for the quantitative determination of Fe(III in tap water samples.

  10. Negative Ion MALDI Mass Spectrometry of Polyoxometalates (POMs): Mechanism of Singly Charged Anion Formation and Chemical Properties Evaluation

    Science.gov (United States)

    Boulicault, Jean E.; Alves, Sandra; Cole, Richard B.

    2016-08-01

    MALDI-MS has been developed for the negative ion mode analysis of polyoxometalates (POMs). Matrix optimization was performed using a variety of matrix compounds. A first group of matrixes offers MALDI mass spectra containing abundant intact singly charged anionic adduct ions, as well as abundant in-source fragmentations at elevated laser powers. A relative ranking of the ability to induce POM fragmentation is found to be: DAN > CHCA > CNA > DIT> HABA > DCTB > IAA. Matrixes of a second group provide poorer quality MALDI mass spectra without observable fragments. Sample preparation, including the testing of salt additives, was performed to optimize signals for a model POM, POMc12, the core structure of which bears four negative charges. The matrix 9-cyanoanthracene (CNA) provided the best signals corresponding to singly charged intact POMc12 anions. Decompositions of these intact anionic species were examined in detail, and it was concluded that hydrogen radical-induced mechanisms were not prevalent, but rather that the observed prompt fragments originate from transferred energy derived from initial electronic excitation of the CNA matrix. Moreover, in obtained MALDI mass spectra, clear evidence of electron transfer to analyte POM species was found: a manifestation of the POMs ability to readily capture electrons. The affinity of polyanionic POMc12 toward a variety of cations was evaluated and the following affinity ranking was established: Fe3+ > Al3+ > Li+ > Ga3+ > Co2+ > Cr3+ > Cu2+ > [Mn2+, Mg2+] > [Na+, K+]. Thus, from the available cationic species, specific adducts are preferentially formed, and evidence is given that these higher affinity POM complexes are formed in the gas phase during the early stages of plume expansion.

  11. Positron emission tomography for the dose monitoring of intra-fractionally moving targets in ion beam therapy

    International Nuclear Information System (INIS)

    Stuetzer, Kristin

    2014-01-01

    Ion beam therapy (IBT) is a promising treatment option in radiotherapy. The characteristic physical and biological properties of light ion beams allow for the delivery of highly tumor conformal dose distributions. Related to the sparing of surrounding healthy tissue and nearby organs at risk, it is feasible to escalate the dose in the tumor volume to reach higher tumor control and survival rates. Remarkable clinical outcome was achieved with IBT for radio-resistant, deep-seated, static and well fixated tumor entities. Presumably, more patients could benefit from the advantages of IBT if it would be available for more frequent tumor sites. Those located in the thorax and upper abdominal region are commonly subjected to intra-fractional, respiration related motion. Different motion-compensated dose delivery techniques have been developed for active field shaping with scanned pencil beams and are at least available under experimental conditions at the GSI Helmholtzzentrum fuer Schwerionenforschung (GSI) in Darmstadt, Germany. Since minor unexpected anatomical changes e.g. related to patient mispositioning, tumour shrinkage or tissue swelling could already lead to remarkable deviations between planned and delivered dose distribution, a valuable dose monitoring system is desired for IBT. So far, positron emission tomography (PET) is the only in vivo, in situ and non-invasive qualitative dose monitoring method applied under clinical conditions. Conclusions about the delivered dose distribution can be drawn indirectly from a comparison between two β + -activity distributions: the measured one and an expected one generated by a Monte-Carlo simulation. Dedicated phantoms mainly made up of polymethyl methacrylate (PMMA) and a motion table for regular one-dimensional (1D) motion patterns have been designed and manufactured for the experiments. Furthermore, the general applicability of the 4D MLEM algorithm for more complex motion patterns has been demonstrated by the

  12. Positron emission tomography for the dose monitoring of intra-fractionally moving targets in ion beam therapy

    Energy Technology Data Exchange (ETDEWEB)

    Stuetzer, Kristin

    2014-07-01

    Ion beam therapy (IBT) is a promising treatment option in radiotherapy. The characteristic physical and biological properties of light ion beams allow for the delivery of highly tumor conformal dose distributions. Related to the sparing of surrounding healthy tissue and nearby organs at risk, it is feasible to escalate the dose in the tumor volume to reach higher tumor control and survival rates. Remarkable clinical outcome was achieved with IBT for radio-resistant, deep-seated, static and well fixated tumor entities. Presumably, more patients could benefit from the advantages of IBT if it would be available for more frequent tumor sites. Those located in the thorax and upper abdominal region are commonly subjected to intra-fractional, respiration related motion. Different motion-compensated dose delivery techniques have been developed for active field shaping with scanned pencil beams and are at least available under experimental conditions at the GSI Helmholtzzentrum fuer Schwerionenforschung (GSI) in Darmstadt, Germany. Since minor unexpected anatomical changes e.g. related to patient mispositioning, tumour shrinkage or tissue swelling could already lead to remarkable deviations between planned and delivered dose distribution, a valuable dose monitoring system is desired for IBT. So far, positron emission tomography (PET) is the only in vivo, in situ and non-invasive qualitative dose monitoring method applied under clinical conditions. Conclusions about the delivered dose distribution can be drawn indirectly from a comparison between two β{sup +}-activity distributions: the measured one and an expected one generated by a Monte-Carlo simulation. Dedicated phantoms mainly made up of polymethyl methacrylate (PMMA) and a motion table for regular one-dimensional (1D) motion patterns have been designed and manufactured for the experiments. Furthermore, the general applicability of the 4D MLEM algorithm for more complex motion patterns has been demonstrated by the

  13. Rapid analysis of malathion in blood using head space-solid phase microextraction and selected ion monitoring.

    Science.gov (United States)

    Namera, A; Yashiki, M; Nagasawa, N; Iwasaki, Y; Kojima, T

    1997-08-04

    A simple and rapid method for analysis of malathion in blood was developed using head space-solid phase microextraction (HS-SPME) and gas chromatography mass spectrometry/ electron impact ionization-selected ion monitoring (GC-MS/EI-SIM). A vial containing a blood sample, ammonium sulphate, sulphuric acid and fenitrothion as an internal standard, was heated at 90 degrees C for 15 min. The extraction fiber of the SPME was exposed for 5 min in the head space of the vial. The compounds absorbed on the fiber were detached by exposing the fibre in the injection port of GC-MS. A straight calibration curve was obtained between malathion concentrations of 2.5 to 50.0 micrograms g-1 in blood. No interfering substances were found, and the time for analysis was 40 min for one sample.

  14. Analysis of polyphenolic antioxidants from the fruits of three pouteria species by selected ion monitoring liquid chromatography-mass spectrometry.

    Science.gov (United States)

    Ma, Jun; Yang, Hui; Basile, Margaret J; Kennelly, Edward J

    2004-09-22

    Pouteria campechiana, Pouteria sapota, and Pouteria viridis are tropical plants in the Sapotaceae family that bear edible fruits. The fresh fruits of these three Pouteria species were each extracted, and activity-guided fractionations were performed to identify the antioxidant constituents. Seven polyphenolic antioxidants, gallic acid (1), (+)-gallocatechin (2), (+)-catechin (3), (-)-epicatechin (4), dihydromyricetin (5), (+)-catechin-3-O-gallate (6), and myricitrin (7), were isolated and identified. Extracts of the three Pouteria fruits were analyzed by a selected ion monitoring liquid chromatography-mass spectrometry method to quantify their polyphenolic antioxidants. The highest level of the seven measured polyphenols was found in P. sapota, the second highest in P. viridis, and the lowest in P. campechiana. The levels of the seven polyphenols corresponded with the results of the 1,1-diphenyl-2-picrylhydrazyl assay, by which P. sapota had the highest antioxidant activity, P. viridis the second highest, and P. campechiana the lowest.

  15. Absolute experimental cross sections for the electron impact single, double, triple, and quadruple ionization of Cs/sup +/ ions. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Feeney, R.K.; Hertling, D.R.

    1981-02-28

    The absolute cross sections for the single, double, triple and quadruple ionization of Cs/sup +/ ions by electron impact have been measured from below their respective thresholds to approximately 5000 eV. This determination has been accomplshed using a crossed beam facility in which monoenergetic beams of ions and electrons are caused to intersect at right angles in a well-defined collision volume. Multiply charged, product ions born as a result of the electron impact are deflected into their respective detectors by cascaded electrostatic analyzers. The multiply charged beam current component is measured by means of a vibrating reed electrometer operating in the rate-of-charge mode.

  16. Role of crystallographic anisotropy in the formation of surface layers of single NiTi crystals after ion-plasma alloying

    Energy Technology Data Exchange (ETDEWEB)

    Poletika, T. M., E-mail: poletm@ispms.tsc.ru; Girsova, S. L., E-mail: llm@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); Meisner, L. L., E-mail: girs@ispms.tsc.ru; Meisner, S. N., E-mail: msn@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); National Research Tomsk State University, Tomsk, 634050 (Russian Federation); Shulepov, I. A., E-mail: iashulepov@tpu.ru [National Research Tomsk Polytechnic University, Tomsk, 634050 (Russian Federation)

    2015-10-27

    The structure of the surface and near-surface layers of single crystals of NiTi, differently oriented relative to the direction of ion beam treatment was investigated. The role of the crystallographic orientation in formation of structure of surface layers after ion-plasma alloying was revealed. It was found that the orientation effects of selective sputtering and channeling determine the thickness of the oxide and amorphous layers, the depth of penetration of ions and impurities, the distribution of Ni with depth.

  17. Dielectronic recombination experiments with tungsten ions at the test storage ring and development of a single-particle detector at the cryogenic storage ring

    International Nuclear Information System (INIS)

    Spruck, Kaija

    2015-05-01

    This work is about electron-ion collision experiments at the ion storage rings of the Max Planck Institute for Nuclear Physics in Heidelberg. Absolute recombination rate coefficients of highly-charged tungsten ions featuring an open 4-f-shell structure have been measured at the heavy-ion storage ring TSR. The resulting plasma rate coefficients have been used to probe the significance of newly developed theoretical approaches. Plasma rate coefficients of highly-charged tungsten ions are in particular interesting for the development of plasma models for nuclear fusion reactors, since tungsten is a foreseeable impurity in the fusion plasma. In the relevant temperature range, the experimental results exceed the theoretical data used so far by up to a factor of 10, showing the need for more reliable theoretical calculations. Furthermore, based on the design of the detectors which have been used in the experiments at TSR, a movable single-particle detector for electron-ion recombination studies at the cryogenic storage ring CSR has been developed and installed within the scope of this work. The device has been designed specifically to meet the requirements of the CSR regarding low ion energies and cryogenic ambient temperature conditions. In a series of experiments, the detector was carefully characterised and successfully tested for its compatibility with these requirements. The detector was part of the infrastructure used for the room-temperature commissioning of CSR (2014) and is currently operated as a single-particle counter during the first cryogenic operation of CSR in 2015.

  18. A novel approach to water polution monitoring by combining ion exchange resin and XRF-scanning technique

    Science.gov (United States)

    Huang, J. J.; Lin, S. C.; Löwemark, L.; Liou, Y. H.; Chang, Q. M.; Chang, T. K.; Wei, K. Y.; Croudace, I. W. C.

    2017-12-01

    Due to the rapid industrial expansion, environments are subject to irregular fluctuations and spatial distributions in pollutant concentrations. This study proposes to use ion exchange resin accompanied with the XRF-scanning technique to monitor environmental pollution. As a passive sampling sorbent, the use of ion exchange resin provides a rapid, low cost and simple method to detect episodic pollution signals with a high spatial sampling density. In order to digest large quantities of samples, the fast and non-destructive Itrax-XRF core scanner has been introduced to assess elemental concentrations in the resin samples. Although the XRF scanning results are often considered as a semi-quantitative measurement due to possible absorption or scattering caused by the physical variabilities of scanned materials, the use of resin can minimize such influences owing to the standarization of the sample matrix. In this study, 17 lab-prepared standard resin samples were scanned with the Itrax-XRF core scanner (at 100 s exposure time with the Mo-tube) and compared with the absolute elemental concentrations. Six elements generally used in pollution studies (Cr, Mn, Ni, Cu, Zn, and Pb) were selected, and their regression lines and correlation coefficients were determined. In addition, 5 standard resin samples were scanned at different exposure time settings (1 s, 5 s, 15 s, 30 s, 100 s) to address the influence of exposure time on the accuracy of the measurements. The results show that within the test range (from few ppm to thousands ppm), the correlation coefficients are higher than 0.97, even at the shortest exposure time (1 s). Furthermore, a pilot field survey with 30 resin samples has been conducted in a potentially polluted farm area in central Taiwan to demonstrate the feasibility of this novel approach. The polluted hot zones could be identified and the properties and sources of wastewater pollution can therefore be traced over large areas for the purposes of

  19. Application of highly portable MinION nanopore sequencing technology for the monitoring of nosocomial tuberculosis infection

    Directory of Open Access Journals (Sweden)

    Matthew Bates

    2016-01-01

    Full Text Available Referral hospitals in sub-Saharan Africa concentrate large numbers of tuberculosis (TB and multidrug-resistant TB (MDR-TB patients, failed by community TB services. We have previously shown, from enhanced screening and through autopsy studies, a significant burden of missed TB infections at the University Teaching Hospital, Lusaka, Zambia, with many patients dying or being discharged without treatment. With minimal TB isolation facilities and minimal political will to invest in broader screening and isolation, the risk of nosocomial transmission is likely to be extremely high. Studies from other hospitals in low burden settings and in South Africa have shown that next generation sequencing (NGS is a very powerful tool for rapidly sequencing whole TB genomes and comparing them to confirm or rule out nosocomial transmission. The established platforms for NGS analysis, such as Illumina, are very expensive, immobile, and require regular maintenance, making them a costly inclusion on a research proposal or programmatic intervention grant in Africa. MinION nanopore sequencing has changed the NGS landscape with cheap portable sequencers, rapid simple library preparation (15 min, and automated real-time analysis tools. The application of highly portable MinION nanopore sequencing technology for the monitoring of nosocomial TB infection will be discussed. Preliminary data from our pediatric pneumonia study will demonstrate the detection of TB in induced sputum from children admitted to the University Teaching Hospital.

  20. Intracellular ion monitoring using a gold-core polymer-shell nanosensor architecture

    Energy Technology Data Exchange (ETDEWEB)

    Stanca, S E; Cranfield, C G; Biskup, C [Biomolecular Photonics Group, University Hospital Jena, Teichgraben 8, 07743 Jena (Germany); Nietzsche, S [Centre for Electron Microscopy, University Hospital Jena, Ziegel-muehlenweg 1, 07743 Jena (Germany); Fritzsche, W, E-mail: sarmiza.stanca@mti.uni-jena.de, E-mail: charles.cranfield@mti.uni-jena.de, E-mail: christoph.biskup@mti.uni-jena.de [Institute of Photonic Technology, Albert-Einstein-Strasse 9, 07745 Jena (Germany)

    2010-02-05

    In this study, we describe the design of new ratiometric fluorescent nanosensors, whose architecture is based on a gold core surrounded by a poly(vinyl alcohol)-polyacetal shell. To the gold core, indicator dyes and reference dyes are attached via a cysteine linker. This nanosensor architecture is flexible with regards to the number and types of fluorophore linkages possible. The robust poly(vinyl alcohol)-polyacetal shell protects the fluorophores linked to the core from non-specific interactions with intracellular proteins. The nanosensors developed in this way are biocompatible and can be easily incorporated into mammalian cells without the use of transfection agents. Here, we show the application of these nanosensors for intracellular pH and sodium ion measurements.

  1. Union Jack and checkerboard lattices with easy plane single ion anisotropy

    Science.gov (United States)

    Pires, A. S. T.

    2017-11-01

    The zero-temperature phase diagrams of the antiferromagnetic Union Jack and checkerboard lattices, with spin one and an easy-plane single anisotropy term, are studied using the SU(3) Schwinger boson formalism (also known as flavor wave theory). We find that the Union Jack lattice has a quantum phase transition (QPT) at J2/J1 = 0.707 between a Néel and a collinear phase, while the checkerboard lattice has a QPT at J2/J1 = 0.785, from the Néel to a magnetically disordered phase. The ground state phase diagrams of the two models are different, both from each other and from that of the square lattice antiferromagnet with all the next nearest neighbors. For the checkerboard lattice, we calculate the spin gap and the ground state energy in the disordered phase. This phase is a candidate for a spin liquid state.

  2. Chemical properties of astatine positive single-charged ion in aqueous solutions

    International Nuclear Information System (INIS)

    Milanov, M.; Doberents, V.; Khalkin, V.A.; Marinov, A.

    1983-01-01

    The mobility of the oxidized astatine in solutions H(Na)ClO 4 (μ=0.4 M) - 1x10 -4 M K 2 Cr 2 O 7 has been measured at 25 deg C in the interval 0.63 -4 cm 2 V -1 s -1 , pH 0.63 Usub(c)=2.67x10 -4 cm 2 V -1 s -1 . The effect agrees with the opinion that a single-charged cation of astatine formed in acidic solutions is a strong aquacomplex ((Hsub(2)O)sub(x)At)sup(+) (x=1-2) (protonized hypoastatine acid). Deprotonization constant of this cation is Ksub(dp)=0.032+-0.005. Specific properties of the astatine cation are given. They can be explained, probability, through the peculiarities of its structure

  3. A permeation theory for single-file ion channels: one- and two-step models.

    Science.gov (United States)

    Nelson, Peter Hugo

    2011-04-28

    How many steps are required to model permeation through ion channels? This question is investigated by comparing one- and two-step models of permeation with experiment and MD simulation for the first time. In recent MD simulations, the observed permeation mechanism was identified as resembling a Hodgkin and Keynes knock-on mechanism with one voltage-dependent rate-determining step [Jensen et al., PNAS 107, 5833 (2010)]. These previously published simulation data are fitted to a one-step knock-on model that successfully explains the highly non-Ohmic current-voltage curve observed in the simulation. However, these predictions (and the simulations upon which they are based) are not representative of real channel behavior, which is typically Ohmic at low voltages. A two-step association/dissociation (A/D) model is then compared with experiment for the first time. This two-parameter model is shown to be remarkably consistent with previously published permeation experiments through the MaxiK potassium channel over a wide range of concentrations and positive voltages. The A/D model also provides a first-order explanation of permeation through the Shaker potassium channel, but it does not explain the asymmetry observed experimentally. To address this, a new asymmetric variant of the A/D model is developed using the present theoretical framework. It includes a third parameter that represents the value of the "permeation coordinate" (fractional electric potential energy) corresponding to the triply occupied state n of the channel. This asymmetric A/D model is fitted to published permeation data through the Shaker potassium channel at physiological concentrations, and it successfully predicts qualitative changes in the negative current-voltage data (including a transition to super-Ohmic behavior) based solely on a fit to positive-voltage data (that appear linear). The A/D model appears to be qualitatively consistent with a large group of published MD simulations, but no

  4. Fine-tuning the local symmetry to attain record blocking temperature and magnetic remanence in a single-ion magnet.

    Science.gov (United States)

    Ungur, Liviu; Le Roy, Jennifer J; Korobkov, Ilia; Murugesu, Muralee; Chibotaru, Liviu F

    2014-04-22

    Remanence and coercivity are the basic characteristics of permanent magnets. They are also tightly correlated with the existence of long relaxation times of magnetization in a number of molecular complexes, called accordingly single-molecule magnets (SMMs). Up to now, hysteresis loops with large coercive fields have only been observed in polynuclear metal complexes and metal-radical SMMs. On the contrary, mononuclear complexes, called single-ion magnets (SIM), have shown hysteresis loops of butterfly/phonon bottleneck type, with negligible coercivity, and therefore with much shorter relaxation times of magnetization. A mononuclear Er(III) complex is presented with hysteresis loops having large coercive fields, achieving 7000 Oe at T=1.8 K and field variation as slow as 1 h for the entire cycle. The coercivity persists up to about 5 K, while the hysteresis loops persist to 12 K. Our finding shows that SIMs can be as efficient as polynuclear SMMs, thus opening new perspectives for their applications. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Single glass nanopore-based regenerable sensing platforms with a non-immobilized polyglutamic acid probe for selective detection of cupric ions.

    Science.gov (United States)

    Chen, Lizhen; He, Haili; Xu, Xiaolong; Jin, Yongdong

    2015-08-19

    A single glass capillary nanopore-based sensing platform for rapid and selective detection of cupric ions is demonstrated by utilizing polyglutamic acid (PGA) as a non-immobilized probe. The detection is based on the significant decrease of ionic current through nanopore and the reversal of ion current rectification responses induced by the chelated cupric ions on the probes when in the presence of cupric ions. PGA shows high selectivity for detecting cupric ions rather than other metal ions. The sensitivity of the sensing platform can be improved about 1-2 orders of magnitude by employing asymmetric salt gradients during the measurements. And the PGA-based nanopore sensing platform shows excellent regenerability for Cu(2+) sensing applications. In addition, the method is found effective and reliable for the detection of cupric ions in real samples with small volume down to 20 μL. This nanopore-based sensing platform will find promising practical applications for the detection of cupric ions. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Single Gold Nanoparticle-Based Colorimetric Detection of Picomolar Mercury Ion with Dark-Field Microscopy.

    Science.gov (United States)

    Liu, Xiaojun; Wu, Zhangjian; Zhang, Qingquan; Zhao, Wenfeng; Zong, Chenghua; Gai, Hongwei

    2016-02-16

    Mercury severely damages the environment and human health, particularly when it accumulates in the food chain. Methods for the colorimetric detection of Hg(2+) have increasingly been developed over the past decade because of the progress in nanotechnology. However, the limits of detection (LODs) of these methods are mostly either comparable to or higher than the allowable maximum level (10 nM) in drinking water set by the US Environmental Protection Agency. In this study, we report a single Au nanoparticle (AuNP)-based colorimetric assay for Hg(2+) detection in solution. AuNPs modified with oligonucleotides were fixed on the slide. The fixed AuNPs bound to free AuNPs in the solution in the presence of Hg(2+) because of oligonucleotide hybridization. This process was accompanied by a color change from green to yellow as observed under an optical microscope. The ratio of changed color spots corresponded with Hg(2+) concentration. The LOD was determined as 1.4 pM, which may help guard against mercury accumulation. The proposed approach was applied to environmental samples with recoveries of 98.3 ± 7.7% and 110.0 ± 8.8% for Yuquan River and industrial wastewater, respectively.

  7. Proposed strategy for leak detection, monitoring, and mitigation (LDMM) during Hanford single-shell tank waste retrieval

    Energy Technology Data Exchange (ETDEWEB)

    Iwatate, D.F., Westinghouse Hanford

    1996-07-08

    This document proposes a strategy to address issues related to leakage from single-shell tanks (SSTs) during sluicing. A set of criteria are proposed to capture the relevant issues pertaining to leak detection, monitoring, and mitigation (LDMM), and allow DOE-RL, the Contractor, Ecology, and Hanford Stakeholders to reach consensus on allowable leakage volumes (ALVs). Technical studies and findings that support the proposed strategy, and ALV criteria, are summarized and referenced. This document specifically addresses LDMM for SSTs at Hanford, Washington.

  8. Single and double [ital K]-shell ionization and electron-transfer cross sections for Fe and Ni bombarded by S ions and Fe by Si ions at 1. 25--4. 70 MeV/amu

    Energy Technology Data Exchange (ETDEWEB)

    Tribedi, L.C.; Prasad, K.G.; Tandon, P.N. (Tata Institute of Fundamental Research, Bombay 400005 (India)); Chen, Z.; Lin, C.D. (Department of Physics, Kansas State University, Manhattan, Kansas (United States))

    1994-02-01

    Single and double [ital K]-shell vacancy production and [ital K]-[ital K] electron-transfer cross sections have been measured in the limit of zero target thickness for Fe and Ni induced by 1.25--4.70 MeV/amu [sup 28]Si and [sup 32]S ions. The fluorescence yield [omega][sub [ital k

  9. Monitoring the Effect of Metal Ions on the Mobility of Artemia salina Nauplii

    Directory of Open Access Journals (Sweden)

    Varvara Kokkali

    2011-03-01

    Full Text Available This study aims to measure the effect of toxic aqueous solutions of metals on the mobility of Artemia salina nauplii by using digital image processing. The instrument consists of a camera with a macro lens, a dark chamber, a light source and a laptop computer. Four nauplii were inserted into a macro cuvette, which contained copper, cadmium, iron and zinc ions at various concentrations. The nauplii were then filmed inside the dark chamber for two minutes and the video sequence was processed by a motion tracking algorithm that estimated their mobility. The results obtained by this system were compared to the mortality assay of the Artemia salina nauplii. Despite the small number of tested organisms, this system demonstrates great sensitivity in quantifying the mobility of the nauplii, which leads to significantly lower EC50 values than those of the mortality assay. Furthermore, concentrations of parts per trillion of toxic compounds could be detected for some of the metals. The main novelty of this instrument relies in the sub-pixel accuracy of the tracking algorithm that enables robust measurement of the deterioration of the mobility of Artemia salina even at very low concentrations of toxic metals.

  10. Monitoring Conformational Landscape of Ovine Prion Protein Monomer Using Ion Mobility Coupled to Mass Spectrometry

    Science.gov (United States)

    Van der Rest, Guillaume; Rezaei, Human; Halgand, Frédéric

    2017-02-01

    Prion protein is involved in deadly neurodegenerative diseases. Its pathogenicity is linked to its structural conversion (α-helix to β-strand transition). However, recent studies suggest that prion protein can follow a plurality of conversion pathways, which hints towards different conformers that might coexist in solution. To gain insights on the plasticity of the ovine prion protein (PrP) monomer, wild type (A136, R154, Q171), mutants and deletions of ARQ were studied by traveling wave ion mobility experiments coupled to mass spectrometry. In order to perform the analysis of a large body of data sets, we designed and evaluated the performance of a processing pipeline based on Driftscope peak detection and a homemade script for automated peak assignment, annotation, and quantification on specific multiply charged protein data. Using this approach, we showed that in the gas phase, PrPs are represented by at least three conformer families differing in both charge state distribution and collisional cross-section, in agreement with the work of Hilton et al. (2010). We also showed that this plasticity is borne both by the N- and C-terminal domains. Effect of protein concentration, pH and temperature were also assessed, showing that (1) pH does not affect conformer distributions, (2) protein concentration modifies the conformational landscape of one mutant (I208M) only, and (3) heating leads to other unfolded species and to a modification of the conformer intensity ratios.

  11. DETERMINATION OF A BOUND MUSK XYLENE METABOLITE IN CARP HEMOGLOBIN AS A BIOMARKER OF EXPOSURE BY GAS CHROMATOGRAPHY MASS SPECTROMETRY USING SELECTED ION MONITORING

    Science.gov (United States)

    Musk xylene (MX) is widely used as a fragrance ingredient in commercial toiletries. Identification and quantification of a bound 4-amino-MX (AMX) metabolite was carried out by gas chromatography-mass spectrometry (GC/MS), with selected ion monitoring (SIM). Detection of AMX occur...

  12. Single grain boundary break junction for suspended nanogap electrodes with gapwidth down to 1-2 nm by focused ion beam milling.

    Science.gov (United States)

    Cui, Ajuan; Liu, Zhe; Dong, Huanli; Wang, Yujin; Zhen, Yonggang; Li, Wuxia; Li, Junjie; Gu, Changzhi; Hu, Wenping

    2015-05-20

    Single grain boundary junctions are used for the fabrication of suspended nanogap electrodes with a gapwidth down to 1-2 nm through the break of such junctions by focused ion beam (FIB) milling. With advantages of stability and no debris, such nanogap electrodes are suitable for single molecular electronic device construction. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Ion photon-stimulated desorption as a tool to monitor the physisorption to chemisorption transition of benzene on Si(111) 7 x 7

    CERN Document Server

    Carbone, M; Casaletto, M P; Zanoni, R; Besnard-Ramage, M J; Comtet, G; Dujardin, G; Hellner, L

    2003-01-01

    We investigated the use of ion photodesorption as a tool to monitor the transition from the physisorbed to the chemisorbed state on a surface. The adsorption of benzene on Si(111) 7 x 7 in the temperature range 40-300 K is chosen as a prototype. The D sup + ion photodesorption yield was monitored as a function of temperature at various benzene exposures. Comparative measurements of the C 1s photoelectron yield in the same temperature range enable the physisorbed to chemisorbed state transition to be distinguished from that of the multilayer to the chemisorbed state. We find the onset at 110 K in the first case, and at 130-140 K in the second case. These results demonstrate that ion photodesorption is a potentially interesting method to identify physisorption to chemisorption transitions of adsorbed molecules on surfaces. (letter to the editor)

  14. Effect of swift heavy ion Ag9+ irradiation on the surface morphology, structure and optical properties of AgGaS2 single crystals

    Science.gov (United States)

    Prabukanthan, P.; Asokan, K.; Kanjilal, D.; Dhanasekaran, R.

    2008-12-01

    AgGaS2 (AGS) single crystals grown by chemical vapor transport (CVT) method were irradiated with Ag9+ ions (120 MeV) with various ion fluences. The irradiation was carried out at room temperature (RT) and at liquid nitrogen temperature (LNT). A glancing angle x-ray diffraction (GAXRD) analysis reveals a huge lattice disorder at RT irradiation. This is observed from an increase in the full width at half maximum (FWHM) and a decrease in the intensity of the AGS (1 1 2) peak. However, there is no change in the FWHM of the (1 1 2) peak but the intensity slightly decreases at LNT irradiation. Also, AGS (3 0 3) peak is not observed for the samples irradiated with the fluences of 5 × 1013 and 1 × 1013 ions cm-2 at RT conditions. The GAXRD results show the decrease in degree of crystallinity upon ion irradiation at RT while there is not much degradation in crystallinity upon ion irradiation at LNT. But the LNT irradiation on AGS has its own effects. Atomic force microscope (AFM) studies show that the roughness of AGS increases on increasing the ion fluences at LNT and at RT. Also, it is found that there is an increase in the surface defects with fluences of Ag9+ ion irradiation when compared to pristine AGS. UV-visible transmission spectra show that the percentage of transmission and bandgap energy decrease with increasing ion fluences and also that the peaks are broadened at LNT and at RT. The photoluminescence (PL) spectra were analyzed as a function of irradiation ion fluences in the AGS crystals at RT. It has been found that the emission intensities of band-to-band transition decrease with increase of ion fluences at LNT and at RT.

  15. Production of a double-humped ion velocity distribution function in a single-ended Q-machine

    DEFF Research Database (Denmark)

    Andersen, S.A.; Jensen, Vagn Orla; Michelsen, Poul

    1970-01-01

    An experimental method of producing a double-humped velocity distribution function for the ions in a Q-machine is described. The method is based on charge exchange processes between neutral ceasium and the ions in a ceasium plasma.......An experimental method of producing a double-humped velocity distribution function for the ions in a Q-machine is described. The method is based on charge exchange processes between neutral ceasium and the ions in a ceasium plasma....

  16. Measurement and Calculation of Absolute Single- and Multiple-Charge-Exchange Cross Sections for Feq+ Ions Impacting CO and CO2

    Energy Technology Data Exchange (ETDEWEB)

    Simcic, J. [Jet Propulsion Laboratory/Caltech; Schultz, David Robert [ORNL; Mawhorter, R. J. [Pomona College; Cadez, I. [Jozef Stefan Institute, Slovenia; Greenwood, J. B. [Queen' s University, Belfast; Chutjian, A. [Jet Propulsion Laboratory/Caltech; Lisse, Carey M. [Johns Hopkins University; Smith, S. J. [Indiana Wesleyan University, Marion

    2010-01-01

    Absolute cross sections are reported for single, double, and triple charge exchange of Feq+ (q=5- 13) ions with CO and CO2. The highly-charged Fe ions are generated in an electron cyclotron resonance ion source. Absolute data are derived from knowledge of the target gas pressure, target path length, and incident and charge-exchanged ion currents. Experimental results are compared with new calculations of these cross sections in the n-electron classical trajectory Monte-Carlo approximation, in which the ensuing radiative and non-radiative cascades are approximated with scaled hydrogenic transition probabilities and scaled Auger rates. The present data are needed in astrophysical applications of solar- and stellar-wind charge-exchange with comets, planetary atmospheres, and circumstellar clouds.

  17. Single and multiple ionization of C60 fullerenes and collective effects in collisions with highly charged C, F, and Si ions with energy 3 MeV/u

    Science.gov (United States)

    Kelkar, A. H.; Kadhane, U.; Misra, D.; Gulyas, L.; Tribedi, L. C.

    2010-10-01

    We have measured absolute cross sections for single, double, triple, and quadruple ionization of C60 in collisions with 3 MeV/u C, F, and Si projectile ions at various projectile charge states. The experiment was performed using the recoil-ion time-of-flight technique. Projectile charge state dependence of the ionization yields was compared mainly with a model based on the giant dipole plasmon resonance (GDPR). In some cases, the continuum-distorted-wave-eikonal-initial-state (CDW-EIS) model which is normally applied for ion-atom collisions was also used as a reference. An excellent qualitative agreement between the experimental data for single and double ionization and the GDPR model predictions was found for all projectile charge states.

  18. Single and multiple ionization of C60 fullerenes and collective effects in collisions with highly charged C, F, and Si ions with energy 3 MeV/u

    International Nuclear Information System (INIS)

    Kelkar, A. H.; Kadhane, U.; Misra, D.; Tribedi, L. C.; Gulyas, L.

    2010-01-01

    We have measured absolute cross sections for single, double, triple, and quadruple ionization of C 60 in collisions with 3 MeV/u C, F, and Si projectile ions at various projectile charge states. The experiment was performed using the recoil-ion time-of-flight technique. Projectile charge state dependence of the ionization yields was compared mainly with a model based on the giant dipole plasmon resonance (GDPR). In some cases, the continuum-distorted-wave-eikonal-initial-state (CDW-EIS) model which is normally applied for ion-atom collisions was also used as a reference. An excellent qualitative agreement between the experimental data for single and double ionization and the GDPR model predictions was found for all projectile charge states.

  19. Foraminiferal single chamber analyses of heavy metals as a tool for monitoring permanent and short term anthropogenic footprints.

    Science.gov (United States)

    Titelboim, Danna; Sadekov, Aleksey; Hyams-Kaphzan, Orit; Almogi-Labin, Ahuva; Herut, Barak; Kucera, Michal; Abramovich, Sigal

    2018-03-01

    In order to establish environmentally sustainable industries there is a need for high-resolution temporal and spatial monitoring of heavy metal pollutants even at low concentrations before they become hazardous for local ecosystems. Here we present single chamber records of Cu, Zn and Pb in shells of two benthic foraminifera species with different shell types from two shallow coastal stations in Israel: An area adjacent to an electrical power plant and desalination factory (Hadera) and an industrially free nature reserve (Nachsholim). Records of both foraminifera species show elevated metal concentrations in Hadera clearly identifying the footprint of the local industrial facilities. Moreover, short-term events of elevated Cu and Pb concentrations were detected by single chamber analyses. This study demonstrates the potential of using heavy metals anomalies in foraminiferal single chambers as a tool for detecting the industrial footprint of coastal facilities as well as short term events of elevated heavy metals. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Erratum : Critical Properties of Spin-1 Antiferromagnetic Heisenberg Chains with Bond Alternation and Uniaxial Single-Ion-Type Anisotropy (vol 69, pg 237, 2000)

    OpenAIRE

    Chen, Wei; 飛田, 和男; Sanctuary, Bryan C.

    2008-01-01

    Original Paper :Critical Properties of Spin-1 Antiferromagnetic Heisenberg Chains with Bond Alternation and Uniaxial Single-Ion-Type AnisotropyWei Chen, Kazuo Hida and Bryan Clifford Sanctuary Journal of the Physical Society of Japan 69 (2000) pp.237-241

  1. Molecular dynamics simulations to examine structure, energetics, and evaporation/condensation dynamics in small charged clusters of water or methanol containing a single monatomic ion.

    Science.gov (United States)

    Daub, Christopher D; Cann, Natalie M

    2012-11-01

    We study small clusters of water or methanol containing a single Ca(2+), Na(+), or Cl(-) ion with classical molecular dynamics simulations, using models that incorporate polarizability via the Drude oscillator framework. Evaporation and condensation of solvent from these clusters is examined in two systems, (1) for isolated clusters initially prepared at different temperatures and (2) those with a surrounding inert (Ar) gas of varying temperature. We examine these clusters over a range of sizes, from almost bare ions up to 40 solvent molecules. We report data on the evaporation and condensation of solvent from the clusters and argue that the observed temperature dependence of evaporation in the smallest clusters demonstrates that the presence of heated gas alone cannot, in most cases, solely account for bare ion production in electrospray ionization (ESI), neglecting the key contribution of the electric field. We also present our findings on the structure and energetics of the clusters as a function of size. Our data agree well with the abundant literature on hydrated ion clusters and offer some novel insight into the structure of methanol and ion clusters, especially those with a Cl(-) anion, where we observe the presence of chain-like structures of methanol molecules. Finally, we provide some data on the reparameterizations necessary to simulate ions in methanol using the separately developed Drude oscillator models for methanol and for ions in water.

  2. Innovative alpha radioactivity monitor for clearance level inspection based on ionized air transport technology (2). CFD-simulated and experimental ion transport efficiencies for uranium-attached pipes

    International Nuclear Information System (INIS)

    Hirata, Yosuke; Nakahara, Katsuhiko; Sano, Akira; Sato, Mitsuyoshi; Aoyama, Yoshio; Miyamoto, Yasuaki; Yamaguchi, Hiromi; Nanbu, Kenichi; Takahashi, Hiroyuki; Oda, Akinori

    2007-01-01

    An innovative alpha radioactivity monitor for clearance level inspection has been developed. This apparatus measures an ion current resulting from air ionization by alpha particles. Ions generated in the measurement chamber of about 1 m 3 in volume are transported by airflow to a sensor and measured. This paper presents computational estimation of ion transport efficiencies for two pipes with different lengths, the inner surfaces of which were covered with a thin layer of uranium. These ion transport efficiencies were compared with those experimentally obtained for the purpose of our model validation. Good agreement was observed between transport efficiencies from simulations and those experimentally estimated. Dependence of the transport efficiencies on the region of uranium coating was also examined, based on which anticipated errors arising from unclear positions of contamination are also discussed. (author)

  3. On-line monitoring system development for single-phase flow accelerated corrosion

    International Nuclear Information System (INIS)

    Lee, Na Young; Lee, Seung Gi; Ryu, Kyung Ha; Hwang, Il Soon

    2007-01-01

    Aged nuclear piping has been reported to undergo corrosion-induced accelerated failures, often without giving signatures to current inspection campaigns. Therefore, we need diverse sensors which can cover a wide area in an on-line application. We suggest an integrated approach to monitor the flow accelerated corrosion (FAC) susceptible piping. Since FAC is a combined phenomenon, we need to monitor as many parameters as possible and that cover wide area, since we do not know where the FAC occurs. For this purpose, we introduce the wearing rate model which focuses on the electrochemical parameters. Using this model, we can predict the wearing rate and then compare testing results. Through analysis we identified feasibility and then developed electrochemical sensors for high temperature application; we also introduced a mechanical monitoring system which is still under development. To support the validation of the monitored results, we adopted high temperature ultrasonic transducer (UT), which shows good resolution in the testing environment. As such, all the monitored results can be compared in terms of thickness. Our validation tests demonstrated the feasibility of sensors. To support direct thickness measurement for a wide-area, the direct current potential drop (DCPD) method will be researched to integrate into the developed framework

  4. Engineering evaluation of alternatives: Technologies for monitoring interstitial liquids in single-shell tanks

    Energy Technology Data Exchange (ETDEWEB)

    Brevick, C.H. [ICF Kaiser Hanford Co., Richland, WA (United States); Jenkins, C.E. [Westinghouse Hanford Co., Richland, WA (United States)

    1996-02-01

    A global search of mature, emerging, and conceptual tank liquid monitoring technologies, along with a historical review of Hanford tank farm waste monitoring instrumentation, was conducted to identify methods for gauging the quantity of interstitial waste liquids contained in Hanford SSTs. Upon completion of the search, an initial screening of alternatives was conducted to identify candidates which might be capable of monitoring interstitial tank liquids. The nine candidate technologies that were selected, evaluated, and ranked are summarized. Hydrostatic tank gauging (HTG) is the technology generally recommended for gauging the quantity of process materials contained in Hanford SSTs. HTG is a mass-based technique that has the capability for continuous remote monitoring. HTG has the advantages of no moving parts, intrinsic safety, and potentially gauging a one-million gal tank with a precision of approximately {+-}500 pounds (i.e., {+-}62 gal of water or {+-}0.02 in. of level in a 75 ft diameter tank). HTG is relatively inexpensive and probe design, construction, testing, installation, and operation should be straightforward. HTG should be configured as part of a hybrid tank gauging system. A hybrid system employs two or more independent measurement systems which function in concert to provide redundancy, improved accuracy, and maximum information at minimum cost. An excellent hybrid system choice for monitoring interstitial liquids in SSTs might be the combination of HTG with thermal differential technology.

  5. Engineering evaluation of alternatives: Technologies for monitoring interstitial liquids in single-shell tanks

    International Nuclear Information System (INIS)

    Brevick, C.H.; Jenkins, C.E.

    1996-02-01

    A global search of mature, emerging, and conceptual tank liquid monitoring technologies, along with a historical review of Hanford tank farm waste monitoring instrumentation, was conducted to identify methods for gauging the quantity of interstitial waste liquids contained in Hanford SSTs. Upon completion of the search, an initial screening of alternatives was conducted to identify candidates which might be capable of monitoring interstitial tank liquids. The nine candidate technologies that were selected, evaluated, and ranked are summarized. Hydrostatic tank gauging (HTG) is the technology generally recommended for gauging the quantity of process materials contained in Hanford SSTs. HTG is a mass-based technique that has the capability for continuous remote monitoring. HTG has the advantages of no moving parts, intrinsic safety, and potentially gauging a one-million gal tank with a precision of approximately ±500 pounds (i.e., ±62 gal of water or ±0.02 in. of level in a 75 ft diameter tank). HTG is relatively inexpensive and probe design, construction, testing, installation, and operation should be straightforward. HTG should be configured as part of a hybrid tank gauging system. A hybrid system employs two or more independent measurement systems which function in concert to provide redundancy, improved accuracy, and maximum information at minimum cost. An excellent hybrid system choice for monitoring interstitial liquids in SSTs might be the combination of HTG with thermal differential technology

  6. Enhanced Sensitivity for Selected Reaction Monitoring Mass Spectrometry-based Targeted Proteomics Using a Dual Stage Electrodynamic Ion Funnel Interface*

    Science.gov (United States)

    Hossain, Mahmud; Kaleta, David T.; Robinson, Errol W.; Liu, Tao; Zhao, Rui; Page, Jason S.; Kelly, Ryan T.; Moore, Ronald J.; Tang, Keqi; Camp, David G.; Qian, Wei-Jun; Smith, Richard D.

    2011-01-01

    Selected reaction monitoring mass spectrometry (SRM-MS) is playing an increasing role in quantitative proteomics and biomarker discovery studies as a method for high throughput candidate quantification and verification. Although SRM-MS offers advantages in sensitivity and quantification compared with other MS-based techniques, current SRM technologies are still challenged by detection and quantification of low abundance proteins (e.g. present at ∼10 ng/ml or lower levels in blood plasma). Here we report enhanced detection sensitivity and reproducibility for SRM-based targeted proteomics by coupling a nanospray ionization multicapillary inlet/dual electrodynamic ion funnel interface to a commercial triple quadrupole mass spectrometer. Because of the increased efficiency in ion transmission, significant enhancements in overall signal intensities and improved limits of detection were observed with the new interface compared with the original interface for SRM measurements of tryptic peptides from proteins spiked into non-depleted mouse plasma over a range of concentrations. Overall, average SRM peak intensities were increased by ∼70-fold. The average level of detection for peptides also improved by ∼10-fold with notably improved reproducibility of peptide measurements as indicated by the reduced coefficients of variance. The ability to detect proteins ranging from 40 to 80 ng/ml within mouse plasma was demonstrated for all spiked proteins without the application of front-end immunoaffinity depletion and fractionation. This significant improvement in detection sensitivity for low abundance proteins in complex matrices is expected to enhance a broad range of SRM-MS applications including targeted protein and metabolite validation. PMID:20410378

  7. Optical spectroscopy of Eu{sup 3+} ions doped in KLu(WO{sub 4}){sub 2} single crystals

    Energy Technology Data Exchange (ETDEWEB)

    Koubaa, T. [Université de Sfax, Faculté des Sciences de Sfax, Département de Physique, Laboratoire de Physique Appliquée, Groupe de Physique des Matériaux Luminescent, Sfax (Tunisia); Dammak, M., E-mail: madidammak@yahoo.com [Université de Sfax, Faculté des Sciences de Sfax, Département de Physique, Laboratoire de Physique Appliquée, Groupe de Physique des Matériaux Luminescent, Sfax (Tunisia); Pujol, M.C.; Aguiló, M.; Díaz, F. [Física i Cristallografia de Materials i Nanomaterials (FiCMA-FiCNA)-EMaS. Universitat Rovira i Virgili (URV), Campus Sescelades, c/ MarcelIi Domingo, 1, E-43007 Tarragona (Spain)

    2015-12-15

    Europium single doped potassium lutetium tungstate Eu{sup 3+}:KLu(WO{sub 4}){sub 2} single crystals have been grown with the top seeded solution growth slow cooling method. Their absorption spectra are studied in detail for principal light polarizations, E||N{sub p}, N{sub m} and N{sub g} at room and low temperatures. The absorption oscillator strengths parameters are calculated by means of the theory of f–f transition intensities for systems with anomalously strong configuration interaction and by Judd–Ofelt theory. The Ω{sub t} (t=2, 4, 6) intensity parameters, and the {O_d_k, O_c_k, Δ_d, Δ_c_1 and Δ_c_2} (k=1, 2, 3) ASCI parameters are calculated. The radiative transition rates A{sub R}, radiative lifetimes τ{sub R}, and fluorescent branching ratios β{sub R} associated with {sup 5}D{sub 0}–{sup 7}F{sub J} transitions of Eu{sup 3+} were determined. The calculated decay times are discussed and compared with experimental values. - Highlights: • Absorption spectra of Eu:KLuW are investigated with respect to principal light polarizations. • Spectroscopic properties of Eu:KLuW are modeled within conventional Judd–Ofelt and (ASCI) theories. • {sup 5}D{sub 0} multiplet shows the contribution of a NR processes and an ET between the Eu{sup 3+} ions. • It is suggested that the Eu{sup 3+}:KLuW is a potential host material for optical applications.

  8. Modulational instability and localized modes in Heisenberg ferromagnetic chains with single-ion easy-axis anisotropy

    Energy Technology Data Exchange (ETDEWEB)

    Tang, Bing, E-mail: bingtangphy@jsu.edu.cn; Li, Guang-Ling; Fu, Mei

    2017-03-15

    A semiclassical theoretical study on the property of the modulational instability of corresponding linear spin-waves and the presence of nonlinear localized excitations in a discrete quantum ferromagnetic spin chain with single-ion easy-axis anisotropy is reported. We consider the Glauber coherent-state representation combined with the Dyson-Maleev transformation for local spin operators as the basic representation of the system, and derive the equation of motion by means of the Ehrenfest theorem. Using a modulational instability analysis of plane waves, we predict the existence regions of bright envelope solitons and intrinsic localized spin-wave modes. Besides, with the help of a semidiscrete multi-scale method, we obtain analytical solutions for the bright envelope soliton and intrinsic localized spin-wave mode. Moreover, we analyze their existence conditions, which agree with the results of modulational instability analysis. - Highlights: • The anisotropy plays significant role in both the property of the modulational instability and the existence conditions for localized modes in ferromagnetic chains. • The analytical solutions of localized modes are obtained. • The appearance conditions for such localized modes agree with the modulational instability analysis.

  9. Scanned ion beam therapy for prostate carcinoma. Comparison of single plan treatment and daily plan-adapted treatment

    International Nuclear Information System (INIS)

    Hild, Sebastian; Graeff, Christian; Rucinski, Antoni; Zink, Klemens; Habl, Gregor; Durante, Marco; Herfarth, Klaus; Bert, Christoph

    2016-01-01

    Intensity-modulated particle therapy (IMPT) for tumors showing interfraction motion is a topic of current research. The purpose of this work is to compare three treatment strategies for IMPT to determine potential advantages and disadvantages of ion prostate cancer therapy. Simulations for three treatment strategies, conventional one-plan radiotherapy (ConvRT), image-guided radiotherapy (IGRT), and online adaptive radiotherapy (ART) were performed employing a dataset of 10 prostate cancer patients with six CT scans taken at one week intervals. The simulation results, using a geometric margin concept (7-2 mm) as well as patient-specific internal target volume definitions for IMPT were analyzed by target coverage and exposure of critical structures on single fraction dose distributions. All strategies led to clinically acceptable target coverage in patients exhibiting small prostate motion (mean displacement < 4 mm), but IGRT and especially ART led to significant sparing of the rectum. In 20 % of the patients, prostate motion exceeded 4 mm causing insufficient target coverage for ConvRT (V95 mean = 0.86, range 0.63-0.99) and IGRT (V95 mean = 0.91, range 0.68-1.00), while ART maintained acceptable target coverage. IMPT of prostate cancer demands consideration of rectal sparing and adaptive treatment replanning for patients exhibiting large prostate motion. (orig.) [de

  10. Towards ion beam synthesis of single CdSe nanocrystal quantum dots in a SiO{sub 2} matrix

    Energy Technology Data Exchange (ETDEWEB)

    Mangold, Hans Moritz; Kinzel, Joerg B.; Krenner, Hubert J. [Emmy Noether Group at Lehrstuhl Experimentalphysik 1, Universitaet Augsburg (Germany); Karl, Helmut [Lehrstuhl Experimentalphysik IV, Universitaet Augsburg (Germany); Wixforth, Achim [Lehrstuhl Experimentalphysik I, Universitaet Augsburg (Germany)

    2013-07-01

    II-VI compound semiconductor quantum dots (QDs) are a promising class of materials for applications in optical devices in the visible spectral domain. Here we show that in addition to traditional fabrication techniques such as molecular beam epitaxy or chemical synthesis, high fluence ion-beam implantation followed by a rapid thermal annealing step, can be readily applied to synthesize CdSe nanocrystals with superior optical properties within the thermal oxide on a Si wafer. In order to confine the implantation volume we employ chromium masks with arrays of nanoscale aperture openings with diameters smaller than 250 nm. We analyzed the such implanted and annealed samples by scanning electron microscopy and micro-photoluminescence spectroscopy. We observe a pronounced broadening and blue shift of the nanocrystal emission when decreasing the aperture diameter to <1000 nm. We attribute this behavior to a reduction of the mean nanocrystal size but increase of its size distribution. For the smallest aperture sizes used we observe a pronounced shell-filling behavior characteristic for single quantum dot nanoemitters.

  11. In situ monitoring of single-wall carbon nanotube laser assisted growth

    NARCIS (Netherlands)

    Haluška, M.; Bellouard, Y.; Burgt, Y. van de; Dietzel, A.H.

    2010-01-01

    Laser assisted catalytic chemical vapor deposition has recently emerged as an attractive method for locally growing carbon nanotubes (CNTs) in a cold wall reactor. So far, reported laser assisted CNT growth has been carried out without insitu process monitoring. This has made it difficult to control

  12. Two-Step Single Particle Mass Spectrometry for On-Line Monitoring of Polycyclic Aromatic Hydrocarbons Bound to Ambient Fine Particulate Matter

    Science.gov (United States)

    Zimmermann, R.; Bente, M.; Sklorz, M.

    2007-12-01

    Polycyclic aromatic hydrocarbons (PAH) are formed as trace products in combustion processes and are emitted to the atmosphere. Larger PAH have low vapour pressure and are predominantly bound to the ambient fine particulate matter (PM). Upon inhalation, PAH show both, chronic human toxicity (i.e. many PAH are potent carcinogens) as well as acute human toxicity (i.e. inflammatory effects due to oxi-dative stress) and are discussed to be relevant for the observed health effect of ambient PM. Therefore a better understanding of the occurrence, dynamics and particle size dependence of particle bound-PAH is of great interest. On-line aerosol mass spectrometry in principle is the method of choice to investigate the size resolved changes in the chemical speciation of particles as well the status of internal vs. external mixing of chemical constituents. However the present available aerosol mass spectrometers (ATOFMS and AMS) do not allow detection of PAH from ambient air PM. In order to allow a single particle based monitoring of PAH from ambient PM a new single particle laser ionisation mass spectrometer was built and applied. The system is based on ATOFMS principle but uses a two- step photo-ionization. A tracked and sized particle firstly is laser desorbed (LD) by a IR-laser pulse (CO2-laser, λ=10.2 μm) and subsequently the released PAH are selectively ionized by an intense UV-laser pulse (ArF excimer, λ=248 nm) in a resonance enhanced multiphoton ionisation process (REMPI). The PAH-ions are detected in a time of flight mass spectrometer (TOFMS). A virtual impactor enrichment unit is used to increase the detection frequency of the ambient particles. With the current inlet system particles from about 400 nm to 10 μm are accessible. Single particle based temporal profiles of PAH containing particles ion (size distribution and PAH speciation) have been recorded in Oberschleissheim, Germany from ambient air. Furthermore profiles of relevant emission sources (e

  13. Water quality monitoring system for determination of ionic nutrients by ion-exclusion chromatography with spectrophotometric detection on cation- and anion-exchange resin columns using water eluent.

    Science.gov (United States)

    Kozaki, Daisuke; Nakatani, Nobutake; Mori, Masanobu; Nakagoshi, Nobukazu; Tanaka, Kazuhiko

    2012-07-01

    A unified ion-exclusion chromatography (IEC) system for monitoring anionic and cationic nutrients like NH4+, NO2-, NO3-, phosphate ion, silicate ion and HCO3- was developed and applied to several environmental waters. The IEC system consisted of four IEC methodologies, including the IEC with ultraviolet (UV) form connected with detection at 210 nm for determining NH4+ on anion-exchange separation column in OH anion-exchange UV-conversion column in I- form in tandem, the IEC with UV-detection at 210 nm for determining simultaneously NO3- and NO3- on cation-exchange separation column in H+ form, the IEC with UV-detection at 210 nm for determining HCO3- on cation-exchange separation column in H+ form connected with anion-exchange UV-conversion column in I- form in tandem, and the IEC with visible-detection based on molybdenum-blue reaction for determining simultaneously silicate and phosphate ions on cation-exchange separation column in H+ form. These IEC systems were combined through three manually-driven 6-port column selection valves to select each separation column to determine selectively the ionic nutrients. Using this sequential water quality monitoring system, the analytical performances such as calibration linearity, reproducibility, detection limit and recovery were also tested under the optimized chromatographic conditions. This novel water quality monitoring system has been applied successfully for the determination of the ionic eutrophication components in sub-urban river waters.

  14. Scattering extraction of ions at CRYRING for SEU testing

    CERN Document Server

    Novák, D; Klamra, W; Norlin, L O; Bagge, L; Kaellberg, A; Paál, A; Rensfelt, K G; Molnár, J

    1999-01-01

    A measuring station has been built at the CRYRING heavy ion accelerator to test the Single Event Upset (SEU) phenomena in working Static RAM circuits. The setup extracts the beam using Rutherford scattering and the ions are monitored with a BaF sub 2 scintillator. SEU measurements have been performed for standard bulk CMOS memory circuits.

  15. Feasibility study of a single-shot 3D electron bunch shape monitor with an electro-optic sampling technique

    Directory of Open Access Journals (Sweden)

    Yuichi Okayasu

    2013-05-01

    Full Text Available We developed a three-dimensional electron bunch charge distribution (3D-BCD monitor with single-shot detection, and a spectral decoding based electro-optic (EO sampling technique for a nondestructive monitor enables real-time reconstruction of the three-dimensional distribution of a bunch charge. We realized three goals by simultaneously probing a number of Pockels EO crystals that surround the electron beam axis with hollow and radial polarized laser pulses. First, we performed a feasibility test as a simple case of a 3D-BCD monitor probing two ZnTe crystals as EO detectors installed on the opposite angle to the electron beam axis and confirmed that we simultaneously obtained both EO signals. Since the adopted hollow probe laser pulse is not only radially polarized but also temporally shifted azimuthally, some disorders in the radial polarization distribution of such a laser pulse were numerically analyzed with a plane-wave expansion method. Based on the above investigations, the 3D-BCD monitor is feasible both in experimental and numerical estimations. Furthermore, we previously developed a femtosecond response organic crystal as a Pockels EO detector and a broadband probe laser (≥350  nm in FWHM; the 3D-BCD monitor realizes 30- to 40-fs (FWHM temporal resolution. Eventually, the monitor is expected to be equipped in such advanced accelerators as XFEL to measure and adjust the electron bunch charge distribution in real time. The 3D-BCD measurement works as a critical tool to provide feedback to seeded FELs.

  16. Time-lapse electrical impedance spectroscopy for monitoring the cell cycle of single immobilized S. pombe cells

    Science.gov (United States)

    Zhu, Zhen; Frey, Olivier; Haandbaek, Niels; Franke, Felix; Rudolf, Fabian; Hierlemann, Andreas

    2015-11-01

    As a complement and alternative to optical methods, wide-band electrical impedance spectroscopy (EIS) enables multi-parameter, label-free and real-time detection of cellular and subcellular features. We report on a microfluidics-based system designed to reliably capture single rod-shaped Schizosaccharomyces pombe cells by applying suction through orifices in a channel wall. The system enables subsequent culturing of immobilized cells in an upright position, while dynamic changes in cell-cycle state and morphology were continuously monitored through EIS over a broad frequency range. Besides measuring cell growth, clear impedance signals for nuclear division have been obtained. The EIS system has been characterized with respect to sensitivity and detection limits. The spatial resolution in measuring cell length was 0.25 μm, which corresponds to approximately a 5-min interval of cell growth under standard conditions. The comprehensive impedance data sets were also used to determine the occurrence of nuclear division and cytokinesis. The obtained results have been validated through concurrent confocal imaging and plausibilized through comparison with finite-element modeling data. The possibility to monitor cellular and intracellular features of single S. pombe cells during the cell cycle at high spatiotemporal resolution renders the presented microfluidics-based EIS system a suitable tool for dynamic single-cell investigations.

  17. Gas Chromatographic-Selected Ion Monitoring-Mass Spectrometric Determination of Cigarette Mainstream Smoke Components with Sensory Attributes

    Directory of Open Access Journals (Sweden)

    Coleman WM

    2014-12-01

    Full Text Available A new method has been developed that detects significant quantitative differences in the amounts of pyrazines, pyridines, furfurals, carboxylic acids, b-damascenone, sclareolide, and megastigmatrienones in the mainstream smoke of a series of five commercial cigarettes. This new quantitative method is based on the gas chromatographic-selected ion monitoring-mass spectrometric (GC-SIM-MS determination of the selected smoke constituents. The accuracy and precision of the approach were well within acceptable parameters with the majority of cases relative standard deviation (RSD values consistently around 5%. Sample preparation was simple requiring only the dissolution of the trapped particulate material in a known volume of methanol followed by injection of this clear dark colored solution into the gas chromatograph. This approach represents an advance in the technology in terms of higher sample throughput and less sample workup. Certain products demonstrated consistent trends in concentration of specific chemical classes. The mainstream smoke from a University of Kentucky reference cigarette, 2R4F, was included for reference purposes. These results are applicable in the overall evaluation of the components responsible for the taste associated with cigarette products.

  18. Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Siketić, Zdravko; Bogdanović Radović, Ivančica; Jakšić, Milko; Popović Hadžija, Marijana; Hadžija, Mirko [Ruđer Bošković Institute, Bijenička cesta 54, 10000 Zagreb (Croatia)

    2015-08-31

    In order to better understand biochemical processes inside an individual cell, it is important to measure the molecular composition at the submicron level. One of the promising mass spectrometry imaging techniques that may be used to accomplish this is Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), using MeV energy heavy ions for excitation. MeV ions have the ability to desorb large intact molecules with a yield that is several orders of magnitude higher than conventional SIMS using keV ions. In order to increase the spatial resolution of the MeV TOF-SIMS system, we propose an independent TOF trigger using a STIM (scanning transmission ion microscopy) detector that is placed just behind the thin transmission target. This arrangement is suitable for biological samples in which the STIM detector simultaneously measures the mass distribution in scanned samples. The capability of the MeV TOF-SIMS setup was demonstrated by imaging the chemical composition of CaCo-2 cells.

  19. Monitoring single-cell gene regulation under dynamically controllable conditions with integrated microfluidics and software.

    Science.gov (United States)

    Kaiser, Matthias; Jug, Florian; Julou, Thomas; Deshpande, Siddharth; Pfohl, Thomas; Silander, Olin K; Myers, Gene; van Nimwegen, Erik

    2018-01-15

    Much is still not understood about how gene regulatory interactions control cell fate decisions in single cells, in part due to the difficulty of directly observing gene regulatory processes in vivo. We introduce here a novel integrated setup consisting of a microfluidic chip and accompanying analysis software that enable long-term quantitative tracking of growth and gene expression in single cells. The dual-input Mother Machine (DIMM) chip enables controlled and continuous variation of external conditions, allowing direct observation of gene regulatory responses to changing conditions in single cells. The Mother Machine Analyzer (MoMA) software achieves unprecedented accuracy in segmenting and tracking cells, and streamlines high-throughput curation with a novel leveraged editing procedure. We demonstrate the power of the method by uncovering several novel features of an iconic gene regulatory program: the induction of Escherichia coli's lac operon in response to a switch from glucose to lactose.

  20. Reliability of Single-Leg Balance and Landing Tests in Rugby Union; Prospect of Using Postural Control to Monitor Fatigue

    Directory of Open Access Journals (Sweden)

    Jordan C. Troester, Jason G. Jasmin, Rob Duffield

    2018-06-01

    Full Text Available The present study examined the inter-trial (within test and inter-test (between test reliability of single-leg balance and single-leg landing measures performed on a force plate in professional rugby union players using commercially available software (SpartaMARS, Menlo Park, USA. Twenty-four players undertook test – re-test measures on two occasions (7 days apart on the first training day of two respective pre-season weeks following 48h rest and similar weekly training loads. Two 20s single-leg balance trials were performed on a force plate with eyes closed. Three single-leg landing trials were performed by jumping off two feet and landing on one foot in the middle of a force plate 1m from the starting position. Single-leg balance results demonstrated acceptable inter-trial reliability (ICC = 0.60-0.81, CV = 11-13% for sway velocity, anterior-posterior sway velocity, and mediolateral sway velocity variables. Acceptable inter-test reliability (ICC = 0.61-0.89, CV = 7-13% was evident for all variables except mediolateral sway velocity on the dominant leg (ICC = 0.41, CV = 15%. Single-leg landing results only demonstrated acceptable inter-trial reliability for force based measures of relative peak landing force and impulse (ICC = 0.54-0.72, CV = 9-15%. Inter-test results indicate improved reliability through the averaging of three trials with force based measures again demonstrating acceptable reliability (ICC = 0.58-0.71, CV = 7-14%. Of the variables investigated here, total sway velocity and relative landing impulse are the most reliable measures of single-leg balance and landing performance, respectively. These measures should be considered for monitoring potential changes in postural control in professional rugby union.

  1. Magnetic properties of weakly exchange-coupled high spin Co(II) ions in pseudooctahedral coordination evaluated by single crystal X-band EPR spectroscopy and magnetic measurements.

    Science.gov (United States)

    Neuman, Nicolás I; Winkler, Elín; Peña, Octavio; Passeggi, Mario C G; Rizzi, Alberto C; Brondino, Carlos D

    2014-03-03

    We report single-crystal X-band EPR and magnetic measurements of the coordination polymer catena-(trans-(μ2-fumarato)tetraaquacobalt(II)), 1, and the Co(II)-doped Zn(II) analogue, 2, in different Zn:Co ratios. 1 presents two magnetically inequivalent high spin S = 3/2 Co(II) ions per unit cell, named A and B, in a distorted octahedral environment coordinated to four water oxygen atoms and trans coordinated to two carboxylic oxygen atoms from the fumarate anions, in which the Co(II) ions are linked by hydrogen bonds and fumarate molecules. Magnetic susceptibility and magnetization measurements of 1 indicate weak antiferromagnetic exchange interactions between the S = 3/2 spins of the Co(II) ions in the crystal lattice. Oriented single crystal EPR experiments of 1 and 2 were used to evaluate the molecular g-tensor and the different exchange coupling constants between the Co(II) ions, assuming an effective spin S′= 1/2. Unexpectedly, the eigenvectors of the molecular g-tensor were not lying along any preferential bond direction, indicating that, in high spin Co(II) ions in roughly octahedral geometry with approximately axial EPR signals, the presence of molecular pseudo axes in the metal site does not determine preferential directions for the molecular g-tensor. The EPR experiment and magnetic measurements, together with a theoretical analysis relating the coupling constants obtained from both techniques, allowed us to evaluate selectively the exchange coupling constant associated with hydrogen bonds that connect magnetically inequivalent Co(II) ions (|JAB(1/2)| = 0.055(2) cm(–1)) and the exchange coupling constant associated with a fumarate bridge connecting equivalent Co(II) ions (|JAA(1/2)| ≈ 0.25 (1) cm(–1)), in good agreement with the average J(3/2) value determined from magnetic measurements.

  2. COMPARISON OF SINGLE NUCLEOTIDE POLYMORPHISMS AND MICROSATELLITES IN NON-INVASIVE GENETIC MONITORING OF A WOLF POPULATION

    DEFF Research Database (Denmark)

    Fabbri, Elena; Caniglia, R.; Mucci, Nadia

    2012-01-01

    Single nucleotide polymorphisms (SNPs) which represent the most widespread source of sequence variation in genomes, are becoming a routine application in several fields such as forensics, ecology and conservation genetics. Their use, requiring short amplifications, may allow a more efficient...... genotyping of degraded DNA. We provide the first application of SNP genotyping in an Italian non-invasive genetic monitoring project of the wolf. We compared three different techniques for genotyping SNPs: pyrosequencing, SNaPshot* and TaqMan* Probe Assay in Real-Time PCR. We successively genotyped nine SNPs....... We evaluated the cost, laboratory effort and reliability of these different markers and discuss the possible future use of VeraCode, SNPlex and Fluidigm EP1 system in wild population monitoring....

  3. The D1 method: career dose estimation from a combination of historical monitoring data and a single year's dose data

    International Nuclear Information System (INIS)

    Sont, W.N.

    1995-01-01

    A method is introduced to estimate career doses from a combination of historical monitoring data and a single year's dose data. This method, called D1 eliminates the bias arising from incorporating historical dose data from times when occupational doses were generally much higher than they are today. Doses calculated by this method are still conditional on the preservation of the status quo in the effectiveness of radiation protection. The method takes into account the variation of the annual dose, and of the probability of being monitored, with the time elapsed since the start of a career. It also allows for the calculation of a standard error of the projected career dose. Results from recent Canadian dose data are presented. (author)

  4. Single-shot beam-position monitor for x-ray free electron laser

    Science.gov (United States)

    Tono, Kensuke; Kudo, Togo; Yabashi, Makina; Tachibana, Takeshi; Feng, Yiping; Fritz, David; Hastings, Jerome; Ishikawa, Tetsuya

    2011-02-01

    We have developed an x-ray beam-position monitor for detecting the radiation properties of an x-ray free electron laser (FEL). It is composed of four PIN photodiodes that detect backscattered x-rays from a semitransparent diamond film placed in the beam path. The signal intensities from the photodiodes are used to compute the beam intensity and position. A proof-of-principle experiment at a synchrotron light source revealed that the error in the beam position is reduced to below 7 μm by using a nanocrystal diamond film prepared by plasma-enhanced chemical vapor deposition. Owing to high dose tolerance and transparency of the diamond film, the monitor is suitable for routine diagnostics of extremely intense x-ray pulses from the FEL.

  5. Pulse-Driven Capacitive Lead Ion Detection with Reduced Graphene Oxide Field-Effect Transistor Integrated with an Analyzing Device for Rapid Water Quality Monitoring.

    Science.gov (United States)

    Maity, Arnab; Sui, Xiaoyu; Tarman, Chad R; Pu, Haihui; Chang, Jingbo; Zhou, Guihua; Ren, Ren; Mao, Shun; Chen, Junhong

    2017-11-22

    Rapid and real-time detection of heavy metals in water with a portable microsystem is a growing demand in the field of environmental monitoring, food safety, and future cyber-physical infrastructure. Here, we report a novel ultrasensitive pulse-driven capacitance-based lead ion sensor using self-assembled graphene oxide (GO) monolayer deposition strategy to recognize the heavy metal ions in water. The overall field-effect transistor (FET) structure consists of a thermally reduced graphene oxide (rGO) channel with a thin layer of Al 2 O 3 passivation as a top gate combined with sputtered gold nanoparticles that link with the glutathione (GSH) probe to attract Pb 2+ ions in water. Using a preprogrammed microcontroller, chemo-capacitance based detection of lead ions has been demonstrated with this FET sensor. With a rapid response (∼1-2 s) and negligible signal drift, a limit of detection (LOD) < 1 ppb and excellent selectivity (with a sensitivity to lead ions 1 order of magnitude higher than that of interfering ions) can be achieved for Pb 2+ measurements. The overall assay time (∼10 s) for background water stabilization followed by lead ion testing and calculation is much shorter than common FET resistance/current measurements (∼minutes) and other conventional methods, such as optical and inductively coupled plasma methods (∼hours). An approximate linear operational range (5-20 ppb) around 15 ppb (the maximum contaminant limit by US Environmental Protection Agency (EPA) for lead in drinking water) makes it especially suitable for drinking water quality monitoring. The validity of the pulse method is confirmed by quantifying Pb 2+ in various real water samples such as tap, lake, and river water with an accuracy ∼75%. This capacitance measurement strategy is promising and can be readily extended to various FET-based sensor devices for other targets.

  6. A Comparison and Integration of MiSeq and MinION Platforms for Sequencing Single Source and Mixed Mitochondrial Genomes.

    Directory of Open Access Journals (Sweden)

    Michael R Lindberg

    Full Text Available Single source and multiple donor (mixed samples of human mitochondrial DNA were analyzed and compared using the MinION and the MiSeq platforms. A generalized variant detection strategy was employed to provide a cursory framework for evaluating the reliability and accuracy of mitochondrial sequences produced by the MinION. The feasibility of long-read phasing was investigated to establish its efficacy in quantitatively distinguishing and deconvolving individuals in a mixture. Finally, a proof-of-concept was demonstrated by integrating both platforms in a hybrid assembly that leverages solely mixture data to accurately reconstruct full mitochondrial genomes.

  7. Computation of methodology-independent single-ion solvation properties from molecular simulations. IV. Optimized Lennard-Jones interaction parameter sets for the alkali and halide ions in water

    Science.gov (United States)

    Reif, Maria M.; Hünenberger, Philippe H.

    2011-04-01

    The raw single-ion solvation free energies computed from atomistic (explicit-solvent) simulations are extremely sensitive to the boundary conditions and treatment of electrostatic interactions used during these simulations. However, as shown recently [M. A. Kastenholz and P. H. Hünenberger, J. Chem. Phys. 124, 224501 (2006), 10.1529/biophysj.106.083667; M. M. Reif and P. H. Hünenberger, J. Chem. Phys. 134, 144103 (2010)], the application of appropriate correction terms permits to obtain methodology-independent results. The corrected values are then exclusively characteristic of the underlying molecular model including in particular the ion-solvent van der Waals interaction parameters, determining the effective ion size and the magnitude of its dispersion interactions. In the present study, the comparison of calculated (corrected) hydration free energies with experimental data (along with the consideration of ionic polarizabilities) is used to calibrate new sets of ion-solvent van der Waals (Lennard-Jones) interaction parameters for the alkali (Li+, Na+, K+, Rb+, Cs+) and halide (F-, Cl-, Br-, I-) ions along with either the SPC or the SPC/E water models. The experimental dataset is defined by conventional single-ion hydration free energies [Tissandier et al., J. Phys. Chem. A 102, 7787 (1998), 10.1021/jp982638r; Fawcett, J. Phys. Chem. B 103, 11181] along with three plausible choices for the (experimentally elusive) value of the absolute (intrinsic) hydration free energy of the proton, namely, Δ G_hyd^{ominus }[H+] = -1100, -1075 or -1050 kJ mol-1, resulting in three sets L, M, and H for the SPC water model and three sets LE, ME, and HE for the SPC/E water model (alternative sets can easily be interpolated to intermediate Δ G_hyd^{ominus }[H+] values). The residual sensitivity of the calculated (corrected) hydration free energies on the volume-pressure boundary conditions and on the effective ionic radius entering into the calculation of the correction terms is

  8. Monitoring CBF in clinical routine by dynamic single photon emission tomography (SPECT) of inhaled xenon-133

    DEFF Research Database (Denmark)

    Sugiyama, H; Christensen, J; Skyhøj Olsen, T

    1986-01-01

    A very simple and low-cost brain dedicated, rapidly rotating Single Photon Emission Tomograph SPECT is described. Its use in following patients with ischemic stroke is illustrated by two middle cerebral artery occlusion cases, one with persistent occlusion and low CBF in MCA territory, and one wi...

  9. A rapid automated procedure for laboratory and shipboard spectrophotometric measurements of seawater alkalinity: continuously monitored single-step acid additions

    Science.gov (United States)

    Liu, X.; Byrne, R. H.; Lindemuth, M.; Easley, R. A.; Patsavas, M. C.

    2012-12-01

    An automated system for shipboard and laboratory alkalinity measurements is presented. The simple system, which consists of a Dosimat titrator to deliver acid volumetrically and a USB 4000 spectrophotometer to monitor the titration progress, provides fast, precise and accurate measurements of total alkalinity for oceanographic research. The analytical method is based on single-point HCl titrations of seawater samples of a known volume; bromol cresol purple is used as an indicator to determine the final pH. Field data from an Arctic cruise demonstrates accuracy and precision around 1 micro mol/kg and a sample processing rate of 6 min per sample.

  10. Cell division in Escherichia coli cultures monitored at single cell resolution

    Directory of Open Access Journals (Sweden)

    Luidalepp Hannes

    2008-04-01

    Full Text Available Abstract Background A fundamental characteristic of cells is the ability to divide. To date, most parameters of bacterial cultures, including cell division, have been measured as cell population averages, assuming that all bacteria divide at a uniform rate. Results We monitored the division of individual cells in Escherichia coli cultures during different growth phases. Our experiments are based on the dilution of green fluorescent protein (GFP upon cell division, monitored by flow cytometry. The results show that the vast majority of E. coli cells in exponentially growing cultures divided uniformly. In cultures that had been in stationary phase up to four days, no cell division was observed. However, upon dilution of stationary phase culture into fresh medium, two subpopulations of cells emerged: one that started dividing and another that did not. These populations were detectable by GFP dilution and displayed different side scatter parameters in flow cytometry. Further analysis showed that bacteria in the non-growing subpopulation were not dead, neither was the difference in growth capacity reducible to differences in stationary phase-specific gene expression since we observed uniform expression of several stress-related promoters. The presence of non-growing persisters, temporarily dormant bacteria that are tolerant to antibiotics, has previously been described within growing bacterial populations. Using the GFP dilution method combined with cell sorting, we showed that ampicillin lyses growing bacteria while non-growing bacteria retain viability and that some of them restart growth after the ampicillin is removed. Thus, our method enables persisters to be monitored even in liquid cultures of wild type strains in which persister formation has low frequency. Conclusion In principle, the approaches developed here could be used to detect differences in cell division in response to different environmental conditions and in cultures of unicellular

  11. The interplay of long-range magnetic order and single-ion anisotropy in rare earth nickel germanides

    Energy Technology Data Exchange (ETDEWEB)

    Islam, Z.

    1999-05-10

    This dissertation is concerned with the interplay of long-range order and anisotropy in the tetragonal RNi{sub 2}Ge{sub 2} (R = rare earth) family of compounds. Microscopic magnetic structures were studied using both neutron and x-ray resonant exchange scattering (XRES) techniques. The magnetic structures of Tb, Dy, Eu and Gd members have been determined using high-quality single-crystal samples. This work has correlated a strong Fermi surface nesting to the magnetic ordering in the RNi{sub 2}Ge{sub 2} compounds. Generalized susceptibility, {chi}{sub 0}(q), calculations found nesting to be responsible for both incommensurate ordering wave vector in GdNi{sub 2}Ge{sub 2}, and the commensurate structure in EuNi{sub 2}Ge{sub 2}. A continuous transition from incommensurate to commensurate magnetic structures via band filling is predicted. The surprisingly higher T{sub N} in EuNi{sub 2}Ge{sub 2} than that in GdNi{sub 2}Ge{sub 2} is also explained. Next, all the metamagnetic phases in TbNi{sub 2}Ge{sub 2} with an applied field along the c axis have been characterized with neutron diffraction measurements. A mixed phase model for the first metamagnetic structure consisting of fully-saturated as well as reduced-moment Tb ions is presented. The moment reduction may be due to moment instability which is possible if the exchange is comparable to the low-lying CEF level splitting and the ground state is a singlet. In such a case, certain Tb sites may experience a local field below the critical value needed to reach saturation.

  12. The interplay of long-range magnetic order and single-ion anisotropy in rare earth nickel germanides

    International Nuclear Information System (INIS)

    Islam, Z.

    1999-01-01

    This dissertation is concerned with the interplay of long-range order and anisotropy in the tetragonal RNi 2 Ge 2 (R = rare earth) family of compounds. Microscopic magnetic structures were studied using both neutron and x-ray resonant exchange scattering (XRES) techniques. The magnetic structures of Tb, Dy, Eu and Gd members have been determined using high-quality single-crystal samples. This work has correlated a strong Fermi surface nesting to the magnetic ordering in the RNi 2 Ge 2 compounds. Generalized susceptibility, χ 0 (q), calculations found nesting to be responsible for both incommensurate ordering wave vector in GdNi 2 Ge 2 , and the commensurate structure in EuNi 2 Ge 2 . A continuous transition from incommensurate to commensurate magnetic structures via band filling is predicted. The surprisingly higher T N in EuNi 2 Ge 2 than that in GdNi 2 Ge 2 is also explained. Next, all the metamagnetic phases in TbNi 2 Ge 2 with an applied field along the c axis have been characterized with neutron diffraction measurements. A mixed phase model for the first metamagnetic structure consisting of fully-saturated as well as reduced-moment Tb ions is presented. The moment reduction may be due to moment instability which is possible if the exchange is comparable to the low-lying CEF level splitting and the ground state is a singlet. In such a case, certain Tb sites may experience a local field below the critical value needed to reach saturation

  13. Field-Induced Co(II) Single-Ion Magnets with mer-Directing Ligands but Ambiguous Coordination Geometry.

    Science.gov (United States)

    Peng, Yan; Mereacre, Valeriu; Anson, Christopher E; Zhang, Yiquan; Bodenstein, Tilmann; Fink, Karin; Powell, Annie K

    2017-06-05

    Three air-stable Co(II) mononuclear complexes with different aromatic substituents have been prepared and structurally characterized by single-crystal X-ray diffraction. The mononuclear complexes [Co(H 2 L1) 2 ]·2THF (1), [Co(HL2) 2 ] (2), and [Co(H 2 L3) 2 ]·CH 2 Cl 2 (3) (where H 3 L1, H 2 L2, and H 3 L3 represent 3-hydroxy-naphthalene-2-carboxylic acid (6-hydroxymethyl-pyridin-2-ylmethylene) hydrazide, nicotinic acid (6-hydroxymethyl-pyridin-2-ylmethylene) hydrazide, and 2-hydroxy-benzoic acid (6-hydroxymethyl-pyridin-2-ylmethylene) hydrazide, respectively) feature a distorted mer octahedral coordination geometry. Detailed magnetic studies of 1-3 have been conducted using direct and alternating current magnetic susceptibility data. Field-induced slow magnetic relaxation was observed for these three complexes. There are few examples of such behavior in (distorted) octahedral coordination geometry (OC) Co(II) mononuclear complexes with uniaxial anisotropy. Analysis of the six-coordinate Co(II) mononuclear single-ion magnets (SIMs) in the literature using the SHAPE program revealed that they all show what is best described as distorted trigonal prismatic (TRP) coordination geometry, and in general, these show negative D zero-field splitting (ZFS) values. On the other hand, all the Co(II) mononuclear complexes displaying what is best approximated as distorted octahedral (OC) coordination geometry show positive D values. In the new Co(II) mononuclear complexes we describe here, there is an ambiguity, since the rigid tridentate ligands confer what is best described for an octahedral complex as a mer coordination geometry, but the actual shape of the first coordination sphere is between octahedral and trigonal prismatic. The negative D values observed experimentally and supported by high-level electronic structure calculations are thus in line with a trigonal prismatic geometry. However, a consideration of the rhombicity as indicated by the E value of the ZFS in

  14. Doubly versus Singly Positively Charged Oxygen Ions Back-Scattering from a Silicon Surface under Dynamic O2+ Bombardment

    Czech Academy of Sciences Publication Activity Database

    Franzreb, K.; Williams, P.; Lörinčík, Jan; Šroubek, Zdeněk

    203-204, 1/4 (2003), s. 39-42 ISSN 0169-4332 Institutional research plan: CEZ:AV0Z2067918; CEZ:AV0Z4040901 Keywords : low-energy ion scattering * doubly charged ions * molecular orbital Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.284, year: 2003

  15. Spectroscopic properties of Bi2ZnOB2O6 single crystals doped with Pr3+ ions: Absorption and luminescence investigations

    Science.gov (United States)

    Kasprowicz, D.; Brik, M. G.; Jaroszewski, K.; Pedzinski, T.; Bursa, B.; Głuchowski, P.; Majchrowski, A.; Michalski, E.

    2015-09-01

    Nonlinear optical Bi2ZnOB2O6 single crystals doped with Pr3+ ions were grown using the Kyropoulos method. The absorption and luminescence properties of these new systems were investigated for the first time. The crystals are characterized by the large values of nonlinear optical coefficients. Effective luminescence of the Pr3+ ions makes this system an excellent candidate for the near-infrared (NIR) and/or ultraviolet (UV) to visible (VIS) laser converters. Based on the obtained experimental spectroscopic data, detailed analysis of the absorption and luminescence spectra was performed using the conventional Judd-Ofelt theory. Those transitions, which can be potentially used for laser applications of the Pr3+ ion, have been identified. In addition to the intensity parameters Ω2, Ω4, Ω6 the branching ratios and radiative lifetimes were estimated for all possible transitions in the studied spectral region.

  16. Correlating cell architecture with osteogenesis: first steps towards live single cell monitoring.

    Science.gov (United States)

    Born, A-K; Rottmar, M; Lischer, S; Pleskova, M; Bruinink, A; Maniura-Weber, K

    2009-10-23

    Cell shape and regulation of biological processes such as proliferation and differentiation are to a large degree connected. Investigation of the possible relationship between cell shape and function is therefore important for developing new material concepts for medical applications as well as developing novel cell based sensors. Cell spreading requires a firm contact with the underlying substrate, with focal contacts (FC) being the primary sites of adhesion. They consist of a large number of clustered transmembrane proteins (integrins). FC integrins connect the cell cytoskeleton with the cell substratum. It has been demonstrated that cell spreading increases osteoblast differentiation in pre-osteoblastic progenitors. The gradual process of osteogenesis can be followed by different proteins being expressed at various time points, comprising early (e.g., bone-specific alkaline phosphatase (bALP)) and late genes (e.g., osteocalcin (OC)). In the present study we have used immunohistochemistry and RT-PCR to determine osteogenic differentiation of human bone cells (HBC). For online monitoring, fluorescently-tagged actin and vinculin were used for transfection of HBCs. Transfection of HBCs with an OC promoter gene construct allowed us to online monitor the gradual process of osteogenesis. We found distinct changes in cell architecture upon osteogenic differentiation thus providing evidence for the connection between cell shape and functional state.

  17. Correlating cell architecture with osteogenesis: first steps towards live single cell monitoring

    Directory of Open Access Journals (Sweden)

    A-K Born

    2009-10-01

    Full Text Available Cell shape and regulation of biological processes such as proliferation and differentiation are to a large degree connected. Investigation of the possible relationship between cell shape and function is therefore important for developing new material concepts for medical applications as well as developing novel cell based sensors. Cell spreading requires a firm contact with the underlying substrate, with focal contacts (FC being the primary sites of adhesion. They consist of a large number of clustered transmembrane proteins (integrins. FC integrins connect the cell cytoskeleton with the cell substratum. It has been demonstrated that cell spreading increases osteoblast differentiation in pre-osteoblastic progenitors. The gradual process of osteogenesis can be followed by different proteins being expressed at various time points, comprising early (e.g., bone-specific alkaline phosphatase (bALP and late genes (e.g., osteocalcin (OC. In the present study we have used immunohistochemistry and RT-PCR to determine osteogenic differentiation of human bone cells (HBC. For online monitoring, fluorescently-tagged actin and vinculin were used for transfection of HBCs. Transfection of HBCs with an OC promoter gene construct allowed us to online monitor the gradual process of osteogenesis. We found distinct changes in cell architecture upon osteogenic differentiation thus providing evidence for the connection between cell shape and functional state.

  18. Dyskinesia detection and monitoring by a single sensor in patients with Parkinson's disease.

    Science.gov (United States)

    Lopane, Giovanna; Mellone, Sabato; Chiari, Lorenzo; Cortelli, Pietro; Calandra-Buonaura, Giovanna; Contin, Manuela

    2015-08-01

    In current clinical practice, assessment of levodopa-induced dyskinesias (LIDs) in Parkinson's disease (PD) is based on semiquantitative scales or patients' diaries. We aimed to assess the feasibility, clinical validity, and usability of a waist-worn inertial sensor for discriminating between LIDs and physiological sway in both supervised and unsupervised settings. Forty-six PD patients on L-dopa therapy, 18 de novo PD patients, and 18 healthy controls were enrolled. Patients underwent clinical assessment of motor signs and dyskinesias and kinetic-dynamic L-dopa monitoring, tracked by serial measurements of plasma drug concentrations and motor and postural tests. A subset of features was selected, which showed excellent reliability. Sensitivity and specificity of the selected features for dyskinesia recognition were assessed in both supervised and unsupervised settings with an accuracy of 95% and 86%, respectively. Our preliminary findings suggest that it is feasible to design a reliable sensor-based application for dyskinesia monitoring at home. © 2015 International Parkinson and Movement Disorder Society.

  19. Optimal Continuous-Monitoring Design of Single-arm Phase II Trial Based on the Simulated Annealing Method

    Science.gov (United States)

    Chen, Nan; Lee, J. Jack

    2013-01-01

    Simon’s two-stage design is commonly used in phase II single-arm clinical trials because of its simplicity and smaller sample size under the null hypothesis compared to the one-stage design. Some studies extend this design to accommodate more interim analyses (i.e., three-stage or four-stage designs). However, most of these studies, together with the original Simon’s two-stage design, are based on the exhaustive search method, which is difficult to extend to high-dimensional, general multi-stage designs. In this study, we propose a simulated annealing (SA)-based design to optimize the early stopping boundaries and minimize the expected sample size for multi-stage or continuous monitoring single-arm trials. We compare the results of the SA method, the decision-theoretic method, the predictive probability method, and the posterior probability method. The SA method can reach the smallest expected sample sizes in all scenarios under the constraints of the same type I and type II errors. The expected sample sizes from the SA method are generally 10–20% smaller than those from the posterior probability method or the predictive probability method, and are slightly smaller than those from the decision-theoretic method in almost all scenarios. The SA method offers an excellent alternative in designing phase II trials with continuous monitoring. PMID:23545075

  20. Online differentiation of mineral phase in aerosol particles by ion formation mechanism using a LAAP-TOF single-particle mass spectrometer

    Directory of Open Access Journals (Sweden)

    N. A. Marsden

    2018-01-01

    Full Text Available Mineralogy of silicate mineral dust has a strong influence on climate and ecosystems due to variation in physiochemical properties that result from differences in composition and crystal structure (mineral phase. Traditional offline methods of analysing mineral phase are labour intensive and the temporal resolution of the data is much longer than many atmospheric processes. Single-particle mass spectrometry (SPMS is an established technique for the online size-resolved measurement of particle composition by laser desorption ionisation (LDI followed by time-of-flight mass spectrometry (TOF-MS. Although non-quantitative, the technique is able to identify the presence of silicate minerals in airborne dust particles from markers of alkali metals and silicate molecular ions in the mass spectra. However, the differentiation of mineral phase in silicate particles by traditional mass spectral peak area measurements is not possible. This is because instrument function and matrix effects in the ionisation process result in variations in instrument response that are greater than the differences in composition between common mineral phases.In this study, we introduce a novel technique that enables the differentiation of mineral phase in silicate mineral particles by ion formation mechanism measured from subtle changes in ion arrival times at the TOF-MS detector. Using a combination of peak area and peak centroid measurements, we show that the arrangement of the interstitial alkali metals in the crystal structure, an important property in silicate mineralogy, influences the ion arrival times of elemental and molecular ion species in the negative ion mass spectra. A classification scheme is presented that allowed for the differentiation of illite–smectite, kaolinite and feldspar minerals on a single-particle basis. Online analysis of mineral dust aerosol generated from clay mineral standards produced mineral fractions that are in agreement with bulk

  1. Online differentiation of mineral phase in aerosol particles by ion formation mechanism using a LAAP-TOF single-particle mass spectrometer

    Science.gov (United States)

    Marsden, Nicholas A.; Flynn, Michael J.; Allan, James D.; Coe, Hugh

    2018-01-01

    Mineralogy of silicate mineral dust has a strong influence on climate and ecosystems due to variation in physiochemical properties that result from differences in composition and crystal structure (mineral phase). Traditional offline methods of analysing mineral phase are labour intensive and the temporal resolution of the data is much longer than many atmospheric processes. Single-particle mass spectrometry (SPMS) is an established technique for the online size-resolved measurement of particle composition by laser desorption ionisation (LDI) followed by time-of-flight mass spectrometry (TOF-MS). Although non-quantitative, the technique is able to identify the presence of silicate minerals in airborne dust particles from markers of alkali metals and silicate molecular ions in the mass spectra. However, the differentiation of mineral phase in silicate particles by traditional mass spectral peak area measurements is not possible. This is because instrument function and matrix effects in the ionisation process result in variations in instrument response that are greater than the differences in composition between common mineral phases.In this study, we introduce a novel technique that enables the differentiation of mineral phase in silicate mineral particles by ion formation mechanism measured from subtle changes in ion arrival times at the TOF-MS detector. Using a combination of peak area and peak centroid measurements, we show that the arrangement of the interstitial alkali metals in the crystal structure, an important property in silicate mineralogy, influences the ion arrival times of elemental and molecular ion species in the negative ion mass spectra. A classification scheme is presented that allowed for the differentiation of illite-smectite, kaolinite and feldspar minerals on a single-particle basis. Online analysis of mineral dust aerosol generated from clay mineral standards produced mineral fractions that are in agreement with bulk measurements reported by

  2. Removal of Ni(II), Zn(II) and Pb(II) ions from single metal aqueous solution using rice husk-based activated carbon

    Energy Technology Data Exchange (ETDEWEB)

    Taha, Mohd F., E-mail: faisalt@petronas.com.my; Shaharun, Maizatul S. [Fundamental and Applied Sciences Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, 31750, Perak Darul Ridzuan (Malaysia); Shuib, Anis Suhaila, E-mail: anisuha@petronas.com.my; Borhan, Azry [Chemical Engineering Department, Universiti Teknologi PETRONAS, Bandar Seri Iskandar, 31750, Perak Darul Ridzuan (Malaysia)

    2014-10-24

    An attempt was made to investigate the potential of rice husk-based activated carbon as an alternative low-cost adsorbent for the removal of Ni(II), Zn(II) and Pb(II) ions from single aqueous solution. Rice husk-based activated carbon was prepared via treatment of rice husk with NaOH followed by the carbonization process at 400°C for 2 hours. Three samples, i.e. raw rice husk, rice husk treated with NaOH and rice husk-based activated carbon, were analyzed for their morphological characteristics using field-emission scanning electron microscope/energy dispersive X-ray (FESEM/EDX). These samples were also analyzed for their carbon, hydrogen, nitrogen, oxygen and silica contents using CHN elemental analyzer and FESEM/EDX. The porous properties of rice husk-based activated carbon were determined by Brunauer-Emmett-Teller (BET) surface area analyzer, and its surface area and pore volume were 255 m{sup 2}/g and 0.17 cm{sup 2}/g, respectively. The adsorption studies for the removal of Ni(II), Zn(II) and Pb(II) ions from single metal aqueous solution were carried out at a fixed initial concentration of metal ion (150 ppm) with variation amount of adsorbent (rice husk-based activated carbon) as a function of varied contact time at room temperature. The concentration of each metal ion was analyzed using atomic absorption spectrophotometer (AAS). The results obtained from adsorption studies indicate the potential of rice husk as an economically promising precursor for the preparation of activated carbon for removal of Ni(II), Zn(II) and Pb(II) ions from single aqueous solution. Isotherm and kinetic model analyses suggested that the experimental data of adsorption studies fitted well with Langmuir, Freundlich and second-order kinetic models.

  3. The ion sensitive field effect transistor (ISFET) pH electrode: a new sensor for long term ambulatory pH monitoring.

    OpenAIRE

    Duroux, P; Emde, C; Bauerfeind, P; Francis, C; Grisel, A; Thybaud, L; Arstrong, D; Depeursinge, C; Blum, A L

    1991-01-01

    Intraluminal pH monitoring in man should be performed with disposable multichannel assemblies that allow recordings at multiple sites and prevent transmission of infection. Currently available glass electrodes are unsuitable for this purpose because of their size and price. We have thus constructed and tested a small, combined ion sensitive field effect transistor (ISFET) pH electrode incorporating an integral reference electrode. In vitro studies showed that both ISFET and glass electrodes (...

  4. Aeroflex Single Board Computers and Instrument Circuit Cards for Nuclear Environments Measuring and Monitoring

    International Nuclear Information System (INIS)

    Stratton, Sam; Stevenson, Dave; Magnifico, Mateo

    2013-06-01

    A Single Board Computer (SBC) is an entire computer including all of the required components and I/O interfaces built on a single circuit board. SBC's are used across numerous industrial, military and space flight applications. In the case of military and space implementations, SBC's employ advanced high reliability processors designed for rugged thermal, mechanical and even radiation environments. These processors, in turn, rely on equally advanced support components such as memory, interface, and digital logic. When all of these components are put together on a printed circuit card, the result is a highly reliable Single Board Computer that can perform a wide variety of tasks in very harsh environments. In the area of instrumentation, peripheral circuit cards can be developed that directly interface to the SBC and various radiation measuring devices and systems. Designers use signal conditioning and high reliability Analog to Digital Converters (ADC's) to convert the measuring device signals to digital data suitable for a microprocessor. The data can then be sent to the SBC via high speed communication protocols such as Ethernet or similar type of serial bus. Data received by the SBC can then be manipulated and processed into a form readily available to users. Recent events are causing some in the NPP industry to consider devices and systems with better radiation and temperature performance capability. Systems designed for space application are designed for the harsh environment of space which under certain conditions would be similar to what the electronics will see during a severe nuclear reactor event. The NPP industry should be considering higher reliability electronics for certain critical applications. (authors)

  5. An Integrated Glucose Sensor with an All-Solid-State Sodium Ion-Selective Electrode for a Minimally Invasive Glucose Monitoring System

    Directory of Open Access Journals (Sweden)

    Junko Kojima

    2015-06-01

    Full Text Available We developed a minimally invasive glucose monitoring system that uses a microneedle to permeate the skin surface and a small hydrogel to accumulate interstitial fluid glucose. The measurement of glucose and sodium ion levels in the hydrogel is required for estimating glucose levels in blood; therefore, we developed a small, enzyme-fixed glucose sensor with a high-selectivity, all-solid-state, sodium ion-selective electrode (ISE integrated into its design. The glucose sensor immobilized glucose oxidase showed a good correlation between the glucose levels in the hydrogels and the reference glucose levels (r > 0.99, and exhibited a good precision (coefficient of variation = 2.9%, 0.6 mg/dL. In the design of the sodium ISEs, we used the insertion material Na0.33MnO2 as the inner contact layer and DD16C5 exhibiting high Na+/K+ selectivity as the ionophore. The developed sodium ISE exhibited high selectivity (\\( \\log \\,k^{pot}_{Na,K} = -2.8\\ and good potential stability. The sodium ISE could measure 0.4 mM (10−3.4 M sodium ion levels in the hydrogels containing 268 mM (10−0.57 M KCl. The small integrated sensor (ϕ < 10 mm detected glucose and sodium ions in hydrogels simultaneously within 1 min, and it exhibited sufficient performance for use as a minimally invasive glucose monitoring system.

  6. Resonator QED experiments with single {sup 40}Ca{sup +} ions; Resonator-QED-Experimente mit einzelnen {sup 40}Ca{sup +}-Ionen

    Energy Technology Data Exchange (ETDEWEB)

    Lange, B.

    2006-12-20

    Combining an optical resonator with an ion trap provides the possibility for QED experiments with single or few particles interacting with a single mode of the electro-magnetic field (Cavity-QED). In the present setup, fluctuations in the count rate on a time scale below 30 seconds were purely determined by the photon statistics due to finite emission and detection efficiency, whereas a marginal drift of the system was noticeable above 200 seconds. To find methods to increase the efficiency of the photon source, investigations were conducted and experimental improvements of the setup implemented in the frame of this thesis. Damping of the resonator field and coupling of ion and field were considered as the most important factors. To reduce the damping of the resonator field, a resonator with a smaller transmissivity of the output mirror was set up. The linear trap used in the experiment allows for the interaction of multiple ions with the resonator field, so that more than one photon may be emitted per pump pulse. This was investigated in this thesis with two ions coupled to the resonator. The cross correlation of the emitted photons was measured with the Hanbury Brown-Twiss method. (orig.)

  7. Fine structure of an exciton coupled to a single Fe2 + ion in a CdSe/ZnSe quantum dot

    Science.gov (United States)

    Smoleński, T.; Kazimierczuk, T.; Goryca, M.; Pacuski, W.; Kossacki, P.

    2017-10-01

    We present a polarization-resolved photoluminescence study of the exchange interaction effects in a prototype system consisting of an individual Fe2 + ion and a single neutral exciton confined in a CdSe/ZnSe quantum dot. A maximal possible number of eight fully linearly polarized lines in the bright exciton emission spectrum is observed, evidencing complete degeneracy lifting in the investigated system. We discuss the conditions required for such a scenario to take place: anisotropy of the electron-hole interaction and the zero-field splitting of the Fe2 + ion spin states. Neglecting either of these components is shown to restore partial degeneracy of the transitions, making the excitonic spectrum similar to those previously reported for all other systems of quantum dots with single magnetic dopants.

  8. Radiation damage induced in Al{sub 2}O{sub 3} single crystal sequentially irradiated with reactor neutrons and 90 MeV Xe ions

    Energy Technology Data Exchange (ETDEWEB)

    Zirour, H. [Faculty of Physics, USTHB, BP. 32, El-Alia, Bab-Ezzouar, Algiers (Algeria); Izerrouken, M., E-mail: izerrouken@yahoo.com [Centre de Recherche Nucléaire de Draria, BP. 43, Sebbala, Draria, Algiers (Algeria); Sari, A. [Centre de Recherche Nucléaire de Berine, BP. 108, Ain-Oussara, Djelfa (Algeria)

    2016-06-15

    The present investigation reports the effect of 90 MeV Xe ion irradiation on neutron irradiated Al{sub 2}O{sub 3} single crystals. Three irradiation experiments were performed, with neutrons only, 90 MeV Xe ions only and with neutrons followed by 90 MeV Xe ions. Neutron and 90 MeV Xe ion irradiations were performed at NUR research reactor, Algiers, Algeria and at GANIL accelerator, Caen, France respectively. After irradiation, the radiation damage was investigated by Raman spectroscopy, Fourier Transform Infrared Spectroscopy (FTIR), optical absorption measurements, and X-ray diffraction (XRD) techniques. Raman technique revealed that the concentration of the defects formed in Al{sub 2}O{sub 3} samples subsequently irradiated with neutrons and 90 MeV Xe ions is lower than that formed in Al{sub 2}O{sub 3} samples which were irradiated only with neutrons. This reveals the occurrence of ionization-induced recovery of the neutron damage. Furthermore, as revealed by XRD analysis, a new peak is appeared at about 2θ = 38.03° after irradiation at high fluence (>3 × 10{sup 13} Xe/cm{sup 2}). It can be assigned to the formation of new lattice plane.

  9. TEM investigation of the surface layer structure [111]{sub B2} of the single NiTi crystal modified by the Si-ion beam implantation

    Energy Technology Data Exchange (ETDEWEB)

    Girsova, S. L., E-mail: girs@ispms.tsc.ru; Poletika, T. M., E-mail: poletm@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); Meisner, S. N., E-mail: msn@ispms.tsc.ru; Meisner, L. L., E-mail: llm@ispms.tsc.ru [Institute of Strength Physics and Materials Science SB RAS, Tomsk, 634055 (Russian Federation); National Research Tomsk State University, Tomsk, 634050 (Russian Federation)

    2015-10-27

    The study was carried on for the single NiTi crystals subjected to the Si-ion beam implantation. Using the transmission electron microscopy technique (TEM), the surface layer structure [111]{sub B2} was examined for the treated material. The modified near-surface sublayers were found to have different composition. Thus the uppermost sublayer contained mostly oxides; the lower-lying modified sublayer material was in an amorphous state and the thin underlying sublayer had a defect structure.

  10. Test Standard Revision Update: JESD57, "Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation"

    Science.gov (United States)

    Lauenstein, Jean-Marie

    2015-01-01

    The JEDEC JESD57 test standard, Procedures for the Measurement of Single-Event Effects in Semiconductor Devices from Heavy-Ion Irradiation, is undergoing its first revision since 1996. In this talk, we place this test standard into context with other relevant radiation test standards to show its importance for single-event effect radiation testing for space applications. We show the range of industry, government, and end-user party involvement in the revision. Finally, we highlight some of the key changes being made and discuss the trade-space in which setting standards must be made to be both useful and broadly adopted.

  11. Study of the reaction between methyl 4-nitrobenzenesulfonate and bromide ions in mixed single-chain-gemini micellar solutions: kinetic evidence for morphological transitions.

    Science.gov (United States)

    del Mar Graciani, María; Rodríguez, Amalia; Moyá, María Luisa

    2008-12-15

    The reaction between methyl 4-nitrobenzenesulfonate and bromide ions has been studied in mixed single-chain-gemini micellar solutions of n-dodecyltrimethylammonium bromide, DTAB, and dodecyl tricosaoxyethylene glycol ether, Brij(35), with alkanediyl-alpha-omega-bis(dodecyldimethylammonium) bromide, 12-s-12,2Br(-) (s=3,4,5). Kinetic micellar effects show that an increase in the solution mole fraction of the single-chain surfactant, X(single-chain), results in a diminution of the mixed micelles tendency to form spherocylindrical aggregates upon increasing surfactant concentration. The dependence of the surfactant concentration at which the sphere-to-rod transition occurs, C(*), on X(single-chain) showed through kinetic data was in agreement with results obtained by means of fluorescence measurements.

  12. Reentrant behaviors in the phase diagram of spin-1 planar ferromagnets with easy-axis single-ion anisotropy via the Devlin two-time Green function framework

    Science.gov (United States)

    Mercaldo, M. T.; Rabuffo, I.; De Cesare, L.; Caramico D'Auria, A.

    2017-10-01

    The Devlin two-time Green function framework is used to investigate the role played by the easy-axis single-ion anisotropy on the phase diagram of (d > 2) -dimensional spin-1 planar ferromagnets which exhibit a magnetic-field-induced quantum phase transition (QPT). In this scheme, the exchange anisotropy terms in the equations of motion are treated at the Tyablikov decoupling level while the crystal field anisotropy contribution is handled exactly. The emerging key result is a reentrant structure of the phase diagram close to the quantum critical point for a well defined window of values of the single-ion anisotropy parameter. This experimentally interesting feature was recently recovered by employing the Anderson-Callen decoupling (ACD) which is considered to provide meaningful results only for small values of the single-ion anisotropy parameter. In this context, our findings suggest that the simplest ACD treatment offers the possibility to have, at least qualitatively, a correct physical scenario of quantum criticality close to a field-induced QPT avoiding the limiting mathematical difficulties involved in the Devlin scheme.

  13. Development of Single Cell Raman Spectroscopy for Cancer Screening and Therapy Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Chan, James W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2009-02-24

    The overall goal of this project was to develop a new technology for cancer detection based on single cell laser tweezers Raman spectroscopy (LTRS). This method has the potential to improve the detection of cancer characteristics in single cells by acquiring cellular spectral markers that reflect the intrinsic biology of the cell. These spectral biomarkers are a new form of molecular signatures in the field of cancer research that may hold promise in accurately identifying and diagnosing cancer and measuring patient response to treatment. The primary objectives of this proposed work were to perform a full characterization of the Raman spectra of single normal, transformed, and cancer cells to identify cancer spectral signatures, validate the clinical significance of these results by direct correlation to established clinical parameters for assessing cancer, and to develop the optical technology needed for efficient sampling and analysis of cells needed for the practical use of such a system in the clinic. The results indicated that normal T and B lymphocytes could be distinguished from their neoplastic cultured cells and leukemia patient cells with classification sensitivities and specificities routinely exceeding 90% based on multivariate statistical analysis and leave-one-out cross validation. Differences primarily in the Raman peaks associated with DNA and protein were observed between normal and leukemic cells and were consistent for both the cultured and primary cells. Differences between normal and leukemia patient cells were more subtle than between normal and leukemia cultured cells but were still significant to allow for accurate discrimination. Furthermore, it is revealed that the spectral differences are representative of the neoplastic phenotype of the cells and not a reflection of the different metabolic states (resting versus active) of normal and leukemic cells. The effect of different standard cell fixation protocols (i.e. methanol, paraformaledhye

  14. Monitoring of seismic events from a specific source region using a single regional array: A case study

    Science.gov (United States)

    Gibbons, S. J.; Kværna, T.; Ringdal, F.

    2005-07-01

    In the monitoring of earthquakes and nuclear explosions using a sparse worldwide network of seismic stations, it is frequently necessary to make reliable location estimates using a single seismic array. It is also desirable to screen out routine industrial explosions automatically in order that analyst resources are not wasted upon detections which can, with a high level of confidence, be associated with such a source. The Kovdor mine on the Kola Peninsula of NW Russia is the site of frequent industrial blasts which are well recorded by the ARCES regional seismic array at a distance of approximately 300 km. We describe here an automatic procedure for identifying signals which are likely to result from blasts at the Kovdor mine and, wherever possible, for obtaining single array locations for such events. Carefully calibrated processing parameters were chosen using measurements from confirmed events at the mine over a one-year period for which the operators supplied Ground Truth information. Phase arrival times are estimated using an autoregressive method and slowness and azimuth are estimated using broadband f{-} k analysis in fixed frequency bands and time-windows fixed relative to the initial P-onset time. We demonstrate the improvement to slowness estimates resulting from the use of fixed frequency bands. Events can be located using a single array if, in addition to the P-phase, at least one secondary phase is found with both an acceptable slowness estimate and valid onset-time estimate. We evaluate the on-line system over a twelve month period; every event known to have occured at the mine is detected by the process and 32 out of 53 confirmed events were located automatically. The remaining events were classified as “very likely” Kovdor events and were subsequently located by an analyst. The false alarm rate is low; only 84 very likely Kovdor events were identified during the whole of 2003 and none of these were subsequently located at a large distance from

  15. Synthesis and Characterization of Network Single Ion Conductors(NSIC) Based On Comb-Branched Polyepoxide Ethers and LithiumBis(allylmalonato)borate

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xiao-Guang; Kerr, John B.

    2004-07-11

    Network single ion conductors (NSICs) based on comb-branch polyepoxide ethers and lithium bis(allylmalonato) borate have been synthesized and thoroughly characterized by means of ionic conductivity measurements, electrochemical impedance and by dynamic mechanical analysis (DMA). The materials have been tested as battery electrolytes by cycling in symmetrical Li/Li half cells and in Li/V{sub 6}O{sub 13} full cells in which the NSIC was used as both binder and electrolyte in the cathode electrode and as the electrolyte separator membrane,. The substitution of the trimethylene oxide (TMO) unit into the side chains in place of ethylene oxide (EO) units increased the polymerion mobility (lower glass transition temperature). However, the ionic conductivity was nearly one and half orders of magnitude lower than the corresponding pure EO based single ion conductor at the same salt concentration. This effect may be ascribed to the lower dielectric constant of the TMO side chains that result in a lower concentration of free conducting lithium cations. For a highly cross-linked system (EO/Li=20), only 47 wt% plasticizing solvent (ethylene carbonate (EC)/ethyl methyl carbonate (EMC), 1/1 by wt) could be taken up and the ionic conductivity was only increased by one order of magnitude over the dry polyelectrolyte while for a less densely crosslinked system (EO/Li=80), up to 75 wt% plasticizer could be taken up and the ionic conductivity was increased by nearly two orders of magnitude. A Li/Li symmetric cell that was cycled at 85 C at a current density of 25{micro}Acm{sup -2} showed no concentration polarization or diffusional relaxation, consistent with a lithium ion transference number of one. However, both the bulk and interfacial impedances increased after 20 cycles, apparently due to continued cross-linking reactions within the membrane and on the surface of the lithium electrodes. A Li/V{sub 6}O{sub 13} full cell constructed using a single ion conductor gel (propylene

  16. A Ratiometric Sensor Using Single Chirality Near-Infrared Fluorescent Carbon Nanotubes: Application to In Vivo Monitoring.

    Science.gov (United States)

    Giraldo, Juan P; Landry, Markita P; Kwak, Seon-Yeong; Jain, Rishabh M; Wong, Min Hao; Iverson, Nicole M; Ben-Naim, Micha; Strano, Michael S

    2015-08-26

    Advances in the separation and functionalization of single walled carbon nanotubes (SWCNT) by their electronic type have enabled the development of ratiometric fluorescent SWCNT sensors for the first time. Herein, single chirality SWCNT are independently functionalized to recognize either nitric oxide (NO), hydrogen peroxide (H(2)O(2)), or no analyte (remaining invariant) to create optical sensor responses from the ratio of distinct emission peaks. This ratiometric approach provides a measure of analyte concentration, invariant to the absolute intensity emitted from the sensors and hence, more stable to external noise and detection geometry. Two distinct ratiometric sensors are demonstrated: one version for H(2)O(2), the other for NO, each using 7,6 emission, and each containing an invariant 6,5 emission wavelength. To functionalize these sensors from SWCNT isolated from the gel separation technique, a method for rapid and efficient coating exchange of single chirality sodium dodecyl sulfate-SWCNT is introduced. As a proof of concept, spatial and temporal patterns of the ratio sensor response to H(2)O(2) and, separately, NO, are monitored in leaves of living plants in real time. This ratiometric optical sensing platform can enable the detection of trace analytes in complex environments such as strongly scattering media and biological tissues. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Application of selected ion monitoring to the analysis of triacylglycerols in olive oil by high temperature-gas chromatography/mass spectrometry.

    Science.gov (United States)

    Ruiz-Samblás, C; González-Casado, A; Cuadros-Rodríguez, L; García, F P Rodríguez

    2010-06-30

    The analysis of the triacylglycerol (TAG) composition of oils is a very challenging task, since the TAGs have very similar physico-chemical properties. In this work, a high temperature-gas chromatographic method coupled to electron ionization-mass spectrometry (HT-GC/EI-MS), in the Selected Ion Monitoring (SIM) mode, method was developed for the analysis of TAGs in the olive oil; this is a method suitable for routine analysis. This method was developed using commercially available standard TAGs. The TAGs studied were separated according to their equivalent carbon number and degree of unsaturation. The peak assignment was carried out by locating the characteristic fragment ions having the same retention time on the SIM profile such as [RCO+74](+) and [RCO+128](+) ions, due to the fatty acyl residues on sn-1, sn-2 and sn-3 positions of the TAG molecule and the [M-OCOR](+) ions corresponding to the acyl ions. The developed method was very useful to eliminate the interferences that appeared in the mass spectrum since electron ionization can prevent satisfactory interpretation of spectra. Copyright 2010 Elsevier B.V. All rights reserved.

  18. Condition monitoring of shaft of single-phase induction motor using optical sensor

    Science.gov (United States)

    Fulzele, Asmita G.; Arajpure, V. G.; Holay, P. P.; Patil, N. M.

    2012-05-01

    Transmission type of optical technique is developed to sense the condition of rotating shafts from a distance. A parallel laser beam is passed tangential over the surface of rotating shaft of a single phase induction motor and its flickering shadow is received on a photo sensor. Variations in sensor voltage output are observed on a digital storage oscilloscope. It is demonstrated that this signal carries information about shaft defects like miss alignment, play and impacts in bearings along with surface deformities. Mathematical model of signals corresponding to these shaft defects is developed. During the development and testing of the sensor, effects of reflections are investigated, sensing phenomenon is simulated, frequency response of the sensor is obtained and its performance is compared with conventional accelerometer.

  19. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    CMS Collaboration

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hard sensors. Inside CMS two rings instrumented with 12 single crystal diamond sensors each are installed on both sides of the interaction point. The sensors are subdivided in two pads, and each pad is read out by a dedicated fast radiation hard ASIC in 130 nm CMOS technology. Due to the excellent time resolution collision products will be separated from machine induced background. In the backend a dead-time less histogramming unit is used, and a fast microTCA system with GHz sampling rate is under development. The detector will measure both the on-line luminosity and the background bunch-by-bunch. The performance of a prototype detector in a test-beam will be reported, and results from the operation during data taking will be presented.

  20. A new on-line luminometer and beam conditions monitor using single crystal diamond sensors

    CERN Document Server

    Karacheban, Olena

    2015-01-01

    Instrumentation near the beam-pipe requires extremely radiation hardsensors. Inside CMS two rings instrumented with 12 single crystal diamondsensors each are installed on both sides of the interaction point. Thesensors are subdivided in two pads, and each pad is read out by adedicated fast radiation hard ASIC in 130 nm CMOS technology.Due to the excellent time resolution collision products will be separatedfrom machine induced background. In the backend a dead-time lesshistogramming unit is udsed, and a fast microTCA system with GHz samplingrate is under development.The detector will measure both the on-line luminosity and the backgroundbunch-by-bunch.The performance of a prototype detector in a test-beam will be reported,and results from the operation during data taking will be presented.

  1. Dead time effect on single photon counting for the longitudinal density monitor of LHC

    CERN Document Server

    Bravin, E

    2005-01-01

    The longitudinal distribution of the protons in the two LHC rings needs to be known with high accuracy. This is required for both: the correct operation of the machine and the understanding of beam dynamics effects that can influence the performances of the collider. One possible way of achieving the required time resolution of 50 ps and dynamic range of 10.4 is single photons counting of the synchrotron radiation emitted by the beams using avalanche photo diodes (APDs). Although this kind of devices have very short rise times and allow precise time stamping of detected photons, they also have long recovery times (dead time) of the order of hundreds of nanoseconds, much longer than the bunch length of the LHC beams. For this reason it is important to evaluate the masking effect introduced by this dead time, where photons emitted by protons in different longitudinal positions will have different probabilities of being detected.

  2. Dead time effect on single photon counting for the longitudinal density monitor LHC

    CERN Document Server

    Bravin, E

    2005-01-01

    The longitudinal distribution of the protons in the two LHC rings needs to be known with high accuracy. This is required for both: the correct operation of the machine and the understanding of beam dynamics effects that can influence the performances of the collider. One possible way of achieving the required time resolution of 50 ps and dynamic range of 10.4 is single photons counting of the synchrotron radiation emitted by the beams using avalanche photo diodes (APDs). Although this kind of devices have very short rise times and allow precise time stamping of detected photons, they also have long recovery times (dead time) of the order of humdreds of nanoseconds, much longer than the bunch length of the LHC beams. For this reason it is important to evaluate the masking effect introduced by this dead time, where photons emitted by protons in different longitudinal positions will have different probabilities of being detected.

  3. Establishing a Quantitative Relationship Between Ion and Pulsed-Laser Induced Single Event Soft Errors in Advanced Semiconductor Devices

    Data.gov (United States)

    National Aeronautics and Space Administration — Radiation is a pervasive environmental challenge in space and the upper atmosphere. Ions can interact with microelectronic devices and create unwanted charge leading...

  4. Poisson-Fermi modeling of ion activities in aqueous single and mixed electrolyte solutions at variable temperature

    Science.gov (United States)

    Liu, Jinn-Liang; Eisenberg, Bob

    2018-02-01

    The combinatorial explosion of empirical parameters in tens of thousands presents a tremendous challenge for extended Debye-Hückel models to calculate activity coefficients of aqueous mixtures of the most important salts in chemistry. The explosion of parameters originates from the phenomenological extension of the Debye-Hückel theory that does not take steric and correlation effects of ions and water into account. By contrast, the Poisson-Fermi theory developed in recent years treats ions and water molecules as nonuniform hard spheres of any size with interstitial voids and includes ion-water and ion-ion correlations. We present a Poisson-Fermi model and numerical methods for calculating the individual or mean activity coefficient of electrolyte solutions with any arbitrary number of ionic species in a large range of salt concentrations and temperatures. For each activity-concentration curve, we show that the Poisson-Fermi model requires only three unchanging parameters at most to well fit the corresponding experimental data. The three parameters are associated with the Born radius of the solvation energy of an ion in electrolyte solution that changes with salt concentrations in a highly nonlinear manner.

  5. Highly wearable cuff-less blood pressure and heart rate monitoring with single-arm electrocardiogram and photoplethysmogram signals.

    Science.gov (United States)

    Zhang, Qingxue; Zhou, Dian; Zeng, Xuan

    2017-02-06

    Long-term continuous systolic blood pressure (SBP) and heart rate (HR) monitors are of tremendous value to medical (cardiovascular, circulatory and cerebrovascular management), wellness (emotional and stress tracking) and fitness (performance monitoring) applications, but face several major impediments, such as poor wearability, lack of widely accepted robust SBP models and insufficient proofing of the generalization ability of calibrated models. This paper proposes a wearable cuff-less electrocardiography (ECG) and photoplethysmogram (PPG)-based SBP and HR monitoring system and many efforts are made focusing on above challenges. Firstly, both ECG/PPG sensors are integrated into a single-arm band to provide a super wearability. A highly convenient but challenging single-lead configuration is proposed for weak single-arm-ECG acquisition, instead of placing the electrodes on the chest, or two wrists. Secondly, to identify heartbeats and estimate HR from the motion artifacts-sensitive weak arm-ECG, a machine learning-enabled framework is applied. Then ECG-PPG heartbeat pairs are determined for pulse transit time (PTT) measurement. Thirdly, a PTT&HR-SBP model is applied for SBP estimation, which is also compared with many PTT-SBP models to demonstrate the necessity to introduce HR information in model establishment. Fourthly, the fitted SBP models are further evaluated on the unseen data to illustrate the generalization ability. A customized hardware prototype was established and a dataset collected from ten volunteers was acquired to evaluate the proof-of-concept system. The semi-customized prototype successfully acquired from the left upper arm the PPG signal, and the weak ECG signal, the amplitude of which is only around 10% of that of the chest-ECG. The HR estimation has a mean absolute error (MAE) and a root mean square error (RMSE) of only 0.21 and 1.20 beats per min, respectively. Through the comparative analysis, the PTT&HR-SBP models significantly outperform

  6. Electrochemical monitoring of intracellular enzyme activity of single living mammalian cells by using a double-mediator system

    International Nuclear Information System (INIS)

    Matsumae, Yoshiharu; Takahashi, Yasufumi; Ino, Kosuke; Shiku, Hitoshi; Matsue, Tomokazu

    2014-01-01

    Graphical abstract: NAD(P)H:quinone oxidoreductase (NQO) activity of single HeLa cells were evaluated by using the menadione–ferrocyanide double mediator system combined with scanning electrochemical microscopy (SECM). - Highlights: • NAD(P)H:quinone oxidoreductase activity of single cells were evaluated with SECM. • Fe(CN) 6 3− /menadione concentrations were optimized for long-term SECM monitoring. • Menadione affect the intracellular levels of reactive oxygen species and GSH. • At 100 μM menadione, the Fe(CN) 6 3− generation rate decreased rapidly within 30 min. - Abstract: We evaluated the intracellular NAD(P)H:quinone oxidoreductase (NQO) activity of single HeLa cells by using the menadione–ferrocyanide double-mediator system combined with scanning electrochemical microscopy (SECM). The double-mediator system was used to amplify the current response from the intracellular NQO activity and to reduce menadione-induced cell damage. The electron shuttle between the electrode and menadione was mediated by the ferrocyanide/ferricyanide redox couple. Generation of ferrocyanide was observed immediately after the addition of a lower concentration (10 μM) of menadione. The ferrocyanide generation rate was constant for 120 min. At a higher menadione concentration (100 μM), the ferrocyanide generation rate decreased within 30 min because of the cytotoxic effect of menadione. We also investigated the relationship between intracellular reactive oxygen species or glutathione levels and exposure to different menadione concentrations to determine the optimal condition for SECM with minimal invasiveness. The present study clearly demonstrates that SECM is useful for the analysis of intracellular enzymatic activities in single cells with a double-mediator system

  7. Electrochemical monitoring of intracellular enzyme activity of single living mammalian cells by using a double-mediator system

    Energy Technology Data Exchange (ETDEWEB)

    Matsumae, Yoshiharu [Graduate School of Environmental Studies, Tohoku University, Aramaki 6-6-11-605, Aoba, Sendai 980-8579 (Japan); Takahashi, Yasufumi [Advanced Institute for Materials Research, Tohoku University, Katahira 2-1-1, Aoba, Sendai 980-8577 (Japan); Ino, Kosuke [Graduate School of Environmental Studies, Tohoku University, Aramaki 6-6-11-605, Aoba, Sendai 980-8579 (Japan); Shiku, Hitoshi, E-mail: shiku@bioinfo.che.tohoku.ac.jp [Graduate School of Environmental Studies, Tohoku University, Aramaki 6-6-11-605, Aoba, Sendai 980-8579 (Japan); Matsue, Tomokazu, E-mail: matsue@bioinfo.che.tohoku.ac.jp [Graduate School of Environmental Studies, Tohoku University, Aramaki 6-6-11-605, Aoba, Sendai 980-8579 (Japan); Advanced Institute for Materials Research, Tohoku University, Katahira 2-1-1, Aoba, Sendai 980-8577 (Japan)

    2014-09-09

    Graphical abstract: NAD(P)H:quinone oxidoreductase (NQO) activity of single HeLa cells were evaluated by using the menadione–ferrocyanide double mediator system combined with scanning electrochemical microscopy (SECM). - Highlights: • NAD(P)H:quinone oxidoreductase activity of single cells were evaluated with SECM. • Fe(CN){sub 6}{sup 3−}/menadione concentrations were optimized for long-term SECM monitoring. • Menadione affect the intracellular levels of reactive oxygen species and GSH. • At 100 μM menadione, the Fe(CN){sub 6}{sup 3−} generation rate decreased rapidly within 30 min. - Abstract: We evaluated the intracellular NAD(P)H:quinone oxidoreductase (NQO) activity of single HeLa cells by using the menadione–ferrocyanide double-mediator system combined with scanning electrochemical microscopy (SECM). The double-mediator system was used to amplify the current response from the intracellular NQO activity and to reduce menadione-induced cell damage. The electron shuttle between the electrode and menadione was mediated by the ferrocyanide/ferricyanide redox couple. Generation of ferrocyanide was observed immediately after the addition of a lower concentration (10 μM) of menadione. The ferrocyanide generation rate was constant for 120 min. At a higher menadione concentration (100 μM), the ferrocyanide generation rate decreased within 30 min because of the cytotoxic effect of menadione. We also investigated the relationship between intracellular reactive oxygen species or glutathione levels and exposure to different menadione concentrations to determine the optimal condition for SECM with minimal invasiveness. The present study clearly demonstrates that SECM is useful for the analysis of intracellular enzymatic activities in single cells with a double-mediator system.

  8. Monitoring single event upsets in SRAM-based FPGAs at the SuperKEKB interaction point

    Science.gov (United States)

    Giordano, R.; Tortone, G.; Perrella, S.; Izzo, V.; Aloisio, A.

    2017-07-01

    In February 2016, the SuperKEKB positron-electron high-luminosity collider of the KEK laboratory (Tsukuba, Japan) started being commissioned. A dedicated commissioning detector, named BEAST2, has been used to characterize beam backgrounds before the Belle2 detector was rolled into the beams and to provide tuning parameters for Monte Carlo simulations. BEAST2 consists of a fiberglass support structure and several sub-detectors mounted onto it, including time projection chambers (TPCs) and He-3 tubes. In this work, we present direct measurements of radiation-induced single event upsets in a SRAM-based FPGA device installed in BEAST2 at a distance of ~ 1 m from the beam interaction point. Our goal was to provide experimental results of the expected radiation-induced configuration upset rate and power consumption variation at Belle2 and at other experiments operating in similar radiation environments. Beam currents for both electron and positron rings spanned a range between 50 and 500 mA, therefore providing data about the FPGA operation in different radiation conditions. Even if the machine has not been providing collisions yet, as the beams were not focused to the interaction point, our results show a rate of 0.15 upsets/day averaged over the whole commissioning time frame. We had neither evidence of total dose effects on the FPGA power consumption nor of permanent damage to the device.

  9. Capillary electrophoresis single-strand conformation polymorphism for the monitoring of gastrointestinal microbiota of chicken flocks.

    Science.gov (United States)

    Pissavin, C; Burel, C; Gabriel, I; Beven, V; Mallet, S; Maurice, R; Queguiner, M; Lessire, M; Fravalo, P

    2012-09-01

    The objective of the present study was to evaluate the capillary electrophoresis single-strand conformation polymorphism (CE-SSCP) to characterize poultry gut microbiota and the ability of this molecular method to detect modifications related to rearing conditions to be used as an epidemiological tool. The V3 region of the 16S rRNA gene was selected as the PCR target. Our results showed that this method provides reproducible data. The microbiota analysis of individuals showed that variability between individual fingerprints was higher for ileum and cloaca than for ceca. However, pooling the samples decreased this variability. To estimate the variability within and between farms, we compared molecular gut patterns of animals from the same hatchery reared under similar conditions and fed the same diet in 2 separate farms. Total aerobic bacteria, coliforms, and lactic acid bacteria were enumerated using conventional bacteriological methods. A significant difference was observed for coliforms present in the ceca and the cloaca depending on the farm. Ileal contents fingerprints were more closely related to those of cloacal contents than to those of ceca contents. When comparing samples from the 2 farms, a specific microbiota was highlighted for each farm. For each gut compartment, the microbiota fingerprints were joined in clusters according to the farm. Thus, this rapid and potentially high-throughput method to obtain gut flora fingerprints is sensitive enough to detect a "farm effect" on the balance of poultry gut microbiota despite the birds being fed the same regimens and reared under similar conditions.

  10. [Application of simultaneous determination of inorganic ionic species by advanced ion chromatography for water quality monitoring of river water and wastewater].

    Science.gov (United States)

    Nakatani, Nobutake; Kozaki, Daisuke; Tanaka, Kazuhiko

    2012-04-01

    In this study, our recent work on advanced ion chromatographic methods for the simultaneous determination of inorganic ionic species such as common anions (SO4(2-), Cl(-) and NO3(-)) and cations (Na+, NH4+, K+, Mg2+, and Ca2+), nutrients (phosphate and silicate) and hydrogen ion/alkalinity are summarized first. Then, the applications using these methods for monitoring environmental water quality are also presented. For the determination of common anions and cations with nutrients, the separation was successfully performed by a polymethacrylate-based weakly acidic cation-exchange column of TSKgel Super IC-A/C (Tosoh, 150 mm x 6.0 mm i. d.) and a mixture solution of 100 mmol/L ascorbic acid and 4 mmol/L 18-crown-6 as acidic eluent with dual detection of conductivity and spectrophotometry. For the determination of hydrogen ion/alkalinity, the separation was conducted by TSKgel ODS-100Z column (Tosoh, 150 mm x 4.5 mm i. d.) modified with lithium dodecylsulfate and an eluent of 40 mmol/L LiCl/0.1 mmol/L lithium dodecylsulfate/0.05 mmol/L H2SO4 with conductivity detector. The differences of ion concentration between untreated and treated wastewater showed the variation of ionic species during biological treatment process in a sewage treatment plant. Occurrence and distribution of water-quality conditions were related to the bioavailability and human activity in watershed. From these results, our advanced ion chromatographic methods have contributed significantly for water quality monitoring of environmental waters.

  11. Microstructure and nanomechanical properties of single stalks from diatom Didymosphenia geminata and their change due to adsorption of selected metal ions.

    Science.gov (United States)

    Zgłobicka, Izabela; Chlanda, Adrian; Woźniak, Michał; Łojkowski, Maciej; Szoszkiewicz, Robert; Mazurkiewicz-Pawlicka, Marta; Święszkowski, Wojciech; Wyroba, Elżbieta; Kurzydłowski, Krzysztof J

    2017-08-01

    We present topographical and nanomechanical characterization of single Didymosphenia geminata stalk. We compared the samples before and after adsorption of metal ions from freshwater samples. Transmission electron microscopy studies of single stalk cross-sections have shown three distinct layers and an additional thin extra coat on the external layer (called "EL"). Using scanning electron microscopy and atomic force microscopy (AFM), we found that topography of single stalks after ionic adsorption differed significantly from topography of pristine stalks. AFM nanoindentation studies in ambient conditions yielded elastic moduli of 214 ± 170 MPa for pristine stalks and 294 ± 108 MPa for stalks after ionic adsorption. Statistical tests showed that those results were significantly different. We conducted only preliminary comparisons between ionic adsorption of several stalks in air and in water. While the stalks with ions were on average stiffer than the pristine stalks in air, they became more compliant than the pristine stalks in water. We also heated the stalks and detected EL softening at 50°C ± 15°C. AFM nanoindentation in air on the softened samples yielded elastic moduli of 26 ± 9 MPa for pristine samples and 43 ± 22 MPa for stalks with absorbed metal ions. Substantial decrease of the EL elastic moduli after heating was expected. Significantly different elastic moduli for the samples after ionic adsorption in both cases (i.e., for heated and nonheated samples), as well as behavior of the stalks immersed in water, point to permanent structural EL changes due to ions. © 2017 Phycological Society of America.

  12. Near-Saturation Single-Photon Avalanche Diode Afterpulse and Sensitivity Correction Scheme for the LHC Longitudinal density Monitor

    CERN Document Server

    Bravin, E; Palm, M

    2014-01-01

    Single-Photon Avalanche Diodes (SPADs) monitor the longitudinal density of the LHC beams by measuring the temporal distribution of synchrotron radiation. The relative population of nominally empty RF-buckets (satellites or ghosts) with respect to filled bunches is a key figure for the luminosity calibration of the LHC experiments. Since afterpulsing from a main bunch avalanche can be as high as, or higher than, the signal from satellites or ghosts, an accurate correction algorithm is needed. Furthermore, to reduce the integration time, the amount of light sent to the SPAD is enough so that pile-up effects and afterpulsing cannot be neglected. The SPAD sensitivity has also been found to vary at the end of the active quenching phase. We present a method to characterize and correct for SPAD deadtime, afterpulsing and sensitivity variation near saturation, together with laboratory benchmarking.

  13. Raman spectroscopic monitoring of the bioeffects of nitroglycerin on Hb-O II in single red blood cell

    Science.gov (United States)

    Chiang, Huihua Kenny; Ruan, Hung-Shiang; Cheng, Hung-You; Fang, Tung-Ting

    2007-02-01

    Raman spectroscopy has been shown to have the potential for providing oxygenated ability of erythrocytes. Raman line at 1638 cm-1 has also been reported as one significant oxygenic indicator for erythrocytes. In this research, we develop the Raman spectroscopic monitoring of the bioeffects of Nitroglycerin on hemoglobin oxygen saturation in a single red blood cell (RBC). Nitroglycerin has been frequently used in the management of angina pectoris. Nitroglycerin liberates nitric oxide (NO) to blood vessels. NO is an oxidizer that easily converts hemoglobin to methemoglobin. The conversion may cause the decrease of oxygenated ability of erythrocytes. In this study, we observed the oxidize state of erythrocytes caused by the over dosage of Nitroglycerin. When the dose of Nitroglycerin exceeds 2x10 -4 M, the oxygenic state of erythrocytes decreases significantly. The Raman spectroscopic results demonstrate the observation of the bioeffects of Nitroglycerin on hemoglobin.

  14. Detection of two electrons in low-lying continuum states of a single projectile ion resulting from the collision of a 10.7-MeV Ag4+ ion with an Ar gas atom

    International Nuclear Information System (INIS)

    Richards, J.D.; Breinig, M.; Gaither, C.C.; Berryman, J.W.; Hasson, B.F.

    1993-01-01

    Two electrons, excited just above the double-ionization threshold of an Ag q+ (q=5,6) core in a single collision of a 0.1-MeV/u Ag 4+ projectile ion with an Ar atom, are detected. The electron detector consists of electrically isolated anode segments located behind a microchannel-plate electron multiplier. A large electrostatic 30 degree parallel-plate analyzer is used to deflect the two free electrons, which move with approximately the projectile velocity, into the detector. The cross sections for producing final states consisting of a positively charged ionic core and two electrons just above the threshold for double ionization in ion-atom collisions have been measured. The cross sections for producing states with one electron moving with a kinetic energy less than 0.13 eV in the projectile frame and the other moving with somewhat higher kinetic energy are presented

  15. Comparison of single nucleotide polymorphisms and microsatellites in non-invasive genetic monitoring of a wolf population

    Directory of Open Access Journals (Sweden)

    Fabbri Elena

    2012-01-01

    Full Text Available Single nucleotide polymorphisms (SNPs which represent the most widespread source of sequence variation in genomes, are becoming a routine application in several fields such as forensics, ecology and conservation genetics. Their use, requiring short amplifications, may allow a more efficient genotyping of degraded DNA. We provide the first application of SNP genotyping in an Italian non-invasive genetic monitoring project of the wolf. We compared three different techniques for genotyping SNPs: pyrosequencing, SNaPshot® and TaqMan® Probe Assay in Real-Time PCR. We successively genotyped nine SNPs using the TaqMan Probe Assay in 51 Italian wolves, 57 domestic dogs, 15 wolf x dog hybrids and 313 wolf scats collected in the northern Apennines. The obtained results were used to estimate genetic variability and PCR error rates in SNP genotyping protocols compared to standard microsatellite analysis. We evaluated the cost, laboratory effort and reliability of these different markers and discuss the possible future use of VeraCode, SNPlex and Fluidigm EP1 system in wild population monitoring.

  16. Development of Guidelines for Use of Proton Single-Event Test Data to Bound Single-Event Effect Susceptibility Due to Light Ions

    Data.gov (United States)

    National Aeronautics and Space Administration — Conventional methods for Single-Event Effects (SEE) Hardness Assurance have proven difficult to adapt to Explorer, Cubesat and other risk tolerant platforms with...

  17. Quantitative imaging of chemical composition in single cells by secondary ion mass spectrometry: cisplatin affects calcium stores in renal epithelial cells.

    Science.gov (United States)

    Chandra, Subhash

    2010-01-01

    A detailed protocol for quantitative single cell mass spectrometry imaging (MSI) analysis is described in this chapter with examples of the treatment of cells with anticancer drug, cisplatin. Cisplatin, cis-diamminedichloridoplatinum ii (CDDP), is widely used for the treatment of many malignancies, including testicular, ovarian, bladder, cervical, head and neck, and small cell and non-small cell lung cancers. The possibility of renal injury by cisplatin treatment is a major dose-limiting factor in this cancer therapy. At present, the mechanisms of cisplatin-induced renal cytotoxicity are poorly understood. In this work, secondary ion mass spectrometry (SIMS) was used for investigating cisplatin-induced alterations in intracellular chemical composition in a well-established model (LLC-PK(1) cell line) for studying renal injury. The cells were cryogenically prepared by the sandwich freeze-fracture method for subcellular imaging analysis of chemical composition (total concentrations of K(+), Na(+), and Ca(2+)) in individual cells. The single cell analysis of these diffusible ions necessitates the use of reliable cryogenic sample preparations for SIMS. The sandwich freeze-fracture method offers a simple approach for cryogenically preserving diffusible ions and molecules inside the cells for SIMS analysis. A CAMECA IMS-3f SIMS ion microscope instrument capable of producing chemical images of single cells with 500-nm spatial resolution was used in the study. In cisplatin-treated cells, SIMS imaging showed the presence of detectable amount of platinum at mass 195, as (195)Pt(+) secondary ions in individual cells. SIMS observations also revealed that individual cells differed in their response to cisplatin. While the chemical composition of some cells was unaffected by cisplatin, others showed a reduction in cytoplasmic calcium stores that was not associated with changes in their intracellular K or Na concentrations. Another population of cells displayed an increase in

  18. Solid phase extraction and trace monitoring of cadmium ions in environmental water and food samples based on modified magnetic nanoporous silica

    Energy Technology Data Exchange (ETDEWEB)

    Omidi, Fariborz [Department of Occupational Health Engineering, School of Public Health, Shahroud University of Medical Sciences, Shahroud (Iran, Islamic Republic of); Behbahani, Mohammad, E-mail: mohammadbehbahai89@yahoo.com [Department of Chemistry, Shahid Beheshti University, Evin, Tehran (Iran, Islamic Republic of); Kalate Bojdi, Majid [Faculty of Chemistry, Kharazmi (Tarbiat Moallem) University, Tehran (Iran, Islamic Republic of); Shahtaheri, Seyed Jamaleddin [Department of Occupational Health Engineering, School of Public Health and Institute for Environmental Research, Tehran University of Medical Sciences, Tehran (Iran, Islamic Republic of)

    2015-12-01

    A new method has been developed for trace separation/preconcentration of cadmium ions using pyridine-functionalized magnetic nanoporous silica material (called Py-Fe{sub 3}O{sub 4}@MCM-41) as a new magnetic sorbent and their determination by flame atomic absorption spectrometry (FAAS). The Py-Fe{sub 3}O{sub 4}@MCM-41 sorbent was characterized by thermogravimetric analysis, differential thermal analysis, transmission electron microscopy, Fourier transform infrared spectrometry and X-ray diffraction. The modified Fe{sub 3}O{sub 4}@MCM-41 can be easily separated from an aqueous solution by applying an external magnetic field. Effects of pH, amount of functionalized Fe{sub 3}O{sub 4}@MCM-41, extraction time, type and quantity of eluent, desorption time, and interfering ions on the extraction efficiency were evaluated and optimized. Under the optimized conditions, the detection limit and relative standard deviation was 0.04 μg L{sup –1} and 2.9%, respectively and the maximum adsorption capacity of the synthesized sorbent for cadmium ions was 154 mg g{sup −1}. The proposed method has been applied to the determination of Cd ions at trace levels in real samples such as, rice, onion, carrot, lettuce, parsley, basil, tap water, river water and seawater with satisfactory results. - Highlights: • The introducing of modified magnetic mesoporous silica as a novel magnetic sorbent. • Trace monitoring of cadmium ions. • The limit of detection (LOD) by the proposed solid phase extraction method was 0.04 ng mL{sup −1} for the cadmium ions. • High surface areas and magnetic characteristic of the sorbent. • Maximum adsorption capacity of the sorbent was 154 mg g{sup −1}.

  19. The study of adsorption characteristics Cu2+ and Pb2+ ions onto PHEMA and P(MMA-HEMA) surfaces from aqueous single solution.

    Science.gov (United States)

    Moradi, O; Aghaie, M; Zare, K; Monajjemi, M; Aghaie, H

    2009-10-30

    The adsorption characteristics of Cu2+ and Pb2+ ions onto poly2-hydroxyethyl methacrylate (PHEMA) and copolymer 2-hydroxyethyl methacrylate with monomer methyl methacrylate P(MMA-HEMA) adsorbent surfaces from aqueous single solution were investigated with respect to the changes in the pH of solution, adsorbent composition (changes in the weight percentage of MMA copolymerized with HEMA monomer), contact time and the temperature in the individual aqueous solutions. The linear correlation coefficients of Langmuir and Freundlich isotherms were obtained. The results revealed that the Langmuir isotherm fitted the experimental results better than the Freundlich isotherm. Using the Langmuir model equation, the monolayer adsorption capacity of PHEMA surface was found to be 0.840 and 3.037 mg/g for Cu2+ and Pb2+ ions and adsorption capacity of (PMMA-HEMA) was found to be 31.153 and 31.447 mg/g for Cu2+ and Pb2+ ions, respectively. Changes in the standard Gibbs free energy (DeltaG(0)), standard enthalpy (DeltaH(0)) and standard entropy (DeltaS(0)) show that the adsorption of mentioned ions onto PHEMA and P(MMA-HEMA) are spontaneous and exothermic at 293-323 K.

  20. Selective Single-Step Separation of a Mixture of Three Metal Ions by a Triphasic Ionic-Liquid-Water-Ionic-Liquid Solvent Extraction System.

    Science.gov (United States)

    Vander Hoogerstraete, Tom; Blockx, Jonas; De Coster, Hendrik; Binnemans, Koen

    2015-08-10

    In a conventional solvent extraction system, metal ions are distributed between two immiscible phases, typically an aqueous and an organic phase. In this paper, the proof-of-principle is given for the distribution of metal ions between three immiscible phases, two ionic liquid phases with an aqueous phase in between them. Three-liquid-phase solvent extraction allows separation of a mixture of three metal ions in a single step, whereas at least two steps are required to separate three metals in the case of two-liquid-phase solvent extraction. In the triphasic system, the lower organic phase is comprised of the ionic liquid betainium- or choline bis(trifluoromethylsulfonyl)imide, whereas the upper organic phase is comprised of the ionic liquid trihexyl(tetradecyl)phosphonium bis(trifluoromethylsulfonyl)imide. The triphasic system was used for the separation of a mixture of tin(II), yttrium(III), and scandium(III) ions. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Structural properties of as-grown and reduced Pr2CuO4 single crystals investigated by ion channeling

    International Nuclear Information System (INIS)

    Haga, T.; Abe, Y.

    1996-01-01

    Ion channeling is very sensitive to atomic arrangements and small atomic displacements in real space. Thus, in order to clarify a role of reduction for Pr 2 CuO 4 , ion channeling properties for the materials have been measured in detail. Anomalous increases of dechanneling fractions of Cu and O atoms in the reduced samples have been found. These results could not be explained by the apical oxygen model but probably suggest that O atoms in Cu-O planes are removed by reduction. Taking these results into account, correlation between lattice instability and superconductivity in the material will be discussed. (orig.)

  2. Using ion production to monitor the birth and death of a metastable helium Bose-Einstein condensate

    International Nuclear Information System (INIS)

    Seidelin, S; Sirjean, O; Gomes, J Viana; Boiron, D; Westbrook, C I; Aspect, A

    2003-01-01

    We discuss observations of the ion flux from a cloud of trapped 2 3 S 1 metastable helium atoms. Both Bose-Einstein condensates (BEC) and thermal clouds were investigated. The ion flux is compared with time-of-flight observations of the expanded cloud. We show data concerning BEC formation and decay, as well as measurements of two-and three-body ionization rate constants. We also discuss possible improvements and extensions of our results

  3. Scanned ion beam therapy for prostate carcinoma. Comparison of single plan treatment and daily plan-adapted treatment

    Energy Technology Data Exchange (ETDEWEB)

    Hild, Sebastian [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); University Clinic Erlangen and Friedrich- Alexander-University Erlangen-Nuernberg (FAU), Department of Radiation Oncology, Erlangen (Germany); Graeff, Christian [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); Rucinski, Antoni [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Sapienza Universit' a di Roma, Dipartimento di Scienze di Base e Applicate per Ingegneria, Roma (Italy); INFN, Roma (Italy); Zink, Klemens [University of Applied Sciences, Institute for Medical Physics and Radiation Protection, Giessen (Germany); University Medical Center Giessen-Marburg, Department of Radiotherapy and Radiooncology, Marburg (Germany); Habl, Gregor [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Klinikum rechts der Isar, Technische Universitaet Muenchen (TUM), Department of Radiation Oncology, Munich (Germany); Durante, Marco [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); Technische Universitaet Darmstadt, Faculty of Physics, Darmstadt (Germany); Herfarth, Klaus [University Clinic Heidelberg, Heidelberg Ion-Beam Therapy Center (HIT) and Department of Radiation Oncology, Heidelberg (Germany); Bert, Christoph [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Department of Biophysics, Darmstadt (Germany); University Clinic Erlangen and Friedrich- Alexander-University Erlangen-Nuernberg (FAU), Department of Radiation Oncology, Erlangen (Germany); University Hospital Erlangen, Radiation Oncology, Erlangen (Germany)

    2016-02-15

    Intensity-modulated particle therapy (IMPT) for tumors showing interfraction motion is a topic of current research. The purpose of this work is to compare three treatment strategies for IMPT to determine potential advantages and disadvantages of ion prostate cancer therapy. Simulations for three treatment strategies, conventional one-plan radiotherapy (ConvRT), image-guided radiotherapy (IGRT), and online adaptive radiotherapy (ART) were performed employing a dataset of 10 prostate cancer patients with six CT scans taken at one week intervals. The simulation results, using a geometric margin concept (7-2 mm) as well as patient-specific internal target volume definitions for IMPT were analyzed by target coverage and exposure of critical structures on single fraction dose distributions. All strategies led to clinically acceptable target coverage in patients exhibiting small prostate motion (mean displacement < 4 mm), but IGRT and especially ART led to significant sparing of the rectum. In 20 % of the patients, prostate motion exceeded 4 mm causing insufficient target coverage for ConvRT (V95{sub mean} = 0.86, range 0.63-0.99) and IGRT (V95{sub mean} = 0.91, range 0.68-1.00), while ART maintained acceptable target coverage. IMPT of prostate cancer demands consideration of rectal sparing and adaptive treatment replanning for patients exhibiting large prostate motion. (orig.) [German] Adaptive Therapieansaetze fuer sich interfraktionell bewegende Zielvolumina in der intensitaetsmodulierten Partikeltherapie (IMPT) befinden sich zurzeit in der Entwicklung. In dieser Arbeit werden drei Behandlungsstrategien auf moegliche Vor- und Nachteile in der IMPT des Prostatakarzinoms hin untersucht. Auf Basis eines anonymisierten Datensatzes aus 10 Patienten mit Prostatakarzinom wurden die drei Bestrahlungsstrategien, konventionelle Ein-Plan-Strahlentherapie (ConvRT), bildunterstuetzte Strahlentherapie (IGRT) und tagesaktuelle Strahlentherapie (adaptive radiotherapy,ART), simuliert

  4. Uses of Single Photon Lidar (SPL) in the Monitoring Reporting and Verification of afforestation and carbon offset projects

    Science.gov (United States)

    Dolan, K. A.; DeCola, P.; Dubayah, R.; Huang, W.; Hurtt, G. C.; Tang, H.; Whitehurst, A.

    2017-12-01

    As societies move towards increased valuation of carbon through markets, regulations, and voluntary agreements the need to develop comprehensive, traceable and continuous, carbon monitoring, reporting and verification (MRV) systems has risen in priority locally to globally. Future landuse decisions, to conserve, develop or reforest, rests on the perceived valuation of anthropogenic and ecological benefits, as well as our ability to measure, report, verify, and "project" those benefits. Two carbon markets in the US, the Regional Green House Gas Initiative (RGGI) and the California Cap and Trade, accept carbon credits or offsets from the forestry sector from avoided emissions through forest conservation, by the enhancement land carbon sequestration through improved forest management and through reforestation projects. These investments often go beyond state, and national boundaries. For example, Blue Source a leading investment firm in forest carbon credits invested in over 20,000 acres of Pennsylvania forests in collaboration with The Nature Conservatory (TNC) Forest Conservation Program. Further local to national governments are writing their own climate policies and regulations and are setting targets for forest carbon storage and sequestration as part of their climate action portfolios. Yet, often little resources or effort is left for monitoring the success of projects such as afforestation initiatives once they have been completed. While field data is critical to monitoring efforts, covering the vast areas needed and getting accurate structural information from field campaigns alone can be difficult and costly. The use of Lidar as a supplement to other developed forest monitoring techniques has advanced significantly over the last decade. Here we evaluate the use of single photon lidar (SPL) collected in the summer of 2015, developed for rapidly collecting high-density, three-dimensional data over a variety of terrain targets, to aid in carbon offset MRV on an

  5. Profiling neuronal ion channelopathies with non-invasive brain imaging and dynamic causal models: Case studies of single gene mutations.

    Science.gov (United States)

    Gilbert, Jessica R; Symmonds, Mkael; Hanna, Michael G; Dolan, Raymond J; Friston, Karl J; Moran, Rosalyn J

    2016-01-01

    Clinical assessments of brain function rely upon visual inspection of electroencephalographic waveform abnormalities in tandem with functional magnetic resonance imaging. However, no current technology proffers in vivo assessments of activity at synapses, receptors and ion-channels, the basis of neuronal communication. Using dynamic causal modeling we compared electrophysiological responses from two patients with distinct monogenic ion channelopathies and a large cohort of healthy controls to demonstrate the feasibility of assaying synaptic-level channel communication non-invasively. Synaptic channel abnormality was identified in both patients (100% sensitivity) with assay specificity above 89%, furnishing estimates of neurotransmitter and voltage-gated ion throughput of sodium, calcium, chloride and potassium. This performance indicates a potential novel application as an adjunct for clinical assessments in neurological and psychiatric settings. More broadly, these findings indicate that biophysical models of synaptic channels can be estimated non-invasively, having important implications for advancing human neuroimaging to the level of non-invasive ion channel assays. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Single amino acids in the carboxyl terminal domain of aquaporin-1 contribute to cGMP-dependent ion channel activation

    Directory of Open Access Journals (Sweden)

    Yool Andrea J

    2003-10-01

    Full Text Available Abstract Background Aquaporin-1 (AQP1 functions as an osmotic water channel and a gated cation channel. Activation of the AQP1 ion conductance by intracellular cGMP was hypothesized to involve the carboxyl (C- terminus, based on amino acid sequence alignments with cyclic-nucleotide-gated channels and cGMP-selective phosphodiesterases. Results Voltage clamp analyses of human AQP1 channels expressed in Xenopus oocytes demonstrated that the nitric oxide donor, sodium nitroprusside (SNP; 3–14 mM activated the ionic conductance response in a dose-dependent manner. Block of soluble guanylate cyclase prevented the response. Enzyme immunoassays confirmed a linear dose-dependent relationship between SNP and the resulting intracellular cGMP levels (up to 1700 fmol cGMP /oocyte at 14 mM SNP. Results here are the first to show that the efficacy of ion channel activation is decreased by mutations of AQP1 at conserved residues in the C-terminal domain (aspartate D237 and lysine K243. Conclusions These data support the idea that the limited amino acid sequence similarities found between three diverse classes of cGMP-binding proteins are significant to the function of AQP1 as a cGMP-gated ion channel, and provide direct evidence for the involvement of the AQP1 C-terminal domain in cGMP-mediated ion channel activation.

  7. Partial and total electronic stopping cross sections of atoms for a singly charged helium ion, Part 2

    International Nuclear Information System (INIS)

    Kaneko, T.; Nishikori, M.; Yamato, N.

    1991-08-01

    Partial and total electronic stopping cross sections of atoms with Z (55 ≤ Z ≤ 92) for a He + ion are tabulated as the second part of NIFS-DATA-11 (1991) on the basis of the wave-packet theory. (author)

  8. Scitillation characteristics of PbWO.sub.4./sub. single crystals doped with Th, Zr, Ce, Sb and Mn ions

    Czech Academy of Sciences Publication Activity Database

    Kobayashi, M.; Usuki, Y.; Ishii, M.; Senguttuvan, N.; Tanji, K.; Chiba, M.; Hara, K.; Nikl, Martin; Boháček, Pavel; Boccaro, S.

    2001-01-01

    Roč. 465, - (2001), s. 428-439 ISSN 0168-9002 R&D Projects: GA MŠk ME 159 Institutional research plan: CEZ:AV0Z1010914 Keywords : PbWO 4 * tetravalent-ion (Th 4 ) doping Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.026, year: 2001

  9. ANISOTROPY EFFECTS IN SINGLE-ELECTRON TRANSFER BETWEEN LASER-EXCITED ATOMS AND HIGHLY-CHARGED IONS

    NARCIS (Netherlands)

    Recent collision experiments are reviewed in which one-electron transfer between laser excited target atoms and (highly charged) keV-ions has been studied. Especially results showing a dependence of the charge exchange on the initial target orbital alignment are discussed. The question to what

  10. Optical and Magnetic Resonance Investigations of 3d Ions in Single Crystal Hosts: Candidates for Tunable Solid-State Lasers

    Science.gov (United States)

    1994-04-25

    reconcile the experintal and calculated spectra; evidently, the branching of the optical transition probabilities plays a critical U role in...octahedral Ci 4 ’ in YAG.25 A possible ra- tionale for the lack of observed tetrahedral Ct4" signals in garets is a large D splitting for the chromium ion

  11. Monitoring Hammerhead Ribozyme-Catalyzed Cleavage with a Fluorescein-Labeled Substrate: Effects of Magnesium Ions and Antibiotic Inhibitors. A Biochemistry Laboratory: Part 2

    Science.gov (United States)

    Chow, Christine S.; Somne, Smita; Llano-Sotelo, Beatriz

    1999-05-01

    An experiment is presented that demonstrates current techniques in modern RNA research and introduces a method for nonradioactive monitoring of RNA reactions. The laboratory involves the study of hammerhead ribozyme activity and the influence of metal ions and antibiotics on these important RNA-based reactions. The ribozyme class of RNA catalysts has current applications in both biotechnology and medicine and therefore should be of great interest to upper-level undergraduate students who anticipate careers in these areas. The students gain hands-on experience in working with RNA on a picomole level and also learn about gel electrophoresis, the use of fluorescent tagging, RNA-small molecule interactions, and the role of metal ions in biological systems. This laboratory offers students an opportunity to work with molecules that have direct applications in drug therapy and RNA catalysis.

  12. Crystal Growth and Spectroscopic characterization of chloride and bromide single crystals doped with rare earth ions for the mid infrared amplification

    International Nuclear Information System (INIS)

    Ferrier, A.

    2007-12-01

    This work is devoted to the study of low phonon energy crystals doped with rare earth ions for the realisation of diode-pumped solid state laser sources emitting in the middle infrared. For that purpose, pure and (Er 3+ or Pr 3+ ) doped single crystals of KPb 2 Cl 5 and Tl 3 PbX 5 (X=Cl, Br) have been elaborated by using the Bridgman-Stockbarger method. These non-hygroscopic and congruent melting materials have been found to exhibit phase transitions during the cooling process but which do not limit the elaboration of centimeter-size single crystals. The spectroscopic study of the Er 3+ doped compounds has been performed both at high and low temperatures. It thus appears that these systems present long fluorescence lifetimes and relatively large gain cross sections favorable for a laser emission around 4.5μm. It has been demonstrated further that the up-conversion processes resulting from excited-state absorptions of the Er 3+ ions around the pumping wavelength as well as the energy transfer processes between the Er 3+ ions do not lead to significant optical losses for the laser system. The derived parameters then have been used to build a model and simulate the laser operation of the system following diode pumping around 800 nm. In the end, the spectroscopic study of the Pr 3+ ion in various materials has allowed us to evidence large emission cross sections associated with long fluorescence lifetimes, now favorable to a laser emission around 5μm. (author)

  13. Influence of VO2+ ions on structural and optical properties of potassium succinate-succinic acid single crystal for non-linear optical applications

    Science.gov (United States)

    Juliet sheela, K.; Subramanian, P.

    2018-04-01

    A transparent and good optical quality semi organic single crystal of vanadium doped potassium succinate-succinic acid (KSSA) was synthesized by slow evaporation technique at room temperature. The structural perfection was supported by the powder XRD of the KSSA-VO2+ single crystal. Optical behavior of the material was discovered from the absorption and transmission spectra of UV-vis-NIR characterization. Functional group and presence of metal ion in the specimen are depicted from FTIR traces. From the photoluminescence studies, emission of wavelength in the violet region (418 nm) at the excitation of 243 nm could be ascertained. EDAX, SEM measurements identify presence of elements and pictures the step-line growth and the imperfection presents in the grown crystal. EPR analysis extracts the information about the local site symmetry around the impurity ion, molecular orbital coefficients, admixture coefficients and ground state wave function of VO2+ doped KSSA single crystal. Second harmonic generation (SHG) efficiency of the grown crystal was investigated to explore the NLO characteristic of the material.

  14. UVnovo: A de Novo Sequencing Algorithm Using Single Series of Fragment Ions via Chromophore Tagging and 351 nm Ultraviolet Photodissociation Mass Spectrometry.

    Science.gov (United States)

    Robotham, Scott A; Horton, Andrew P; Cannon, Joe R; Cotham, Victoria C; Marcotte, Edward M; Brodbelt, Jennifer S

    2016-04-05

    De novo peptide sequencing by mass spectrometry represents an important strategy for characterizing novel peptides and proteins, in which a peptide's amino acid sequence is inferred directly from the precursor peptide mass and tandem mass spectrum (MS/MS or MS(3)) fragment ions, without comparison to a reference proteome. This method is ideal for organisms or samples lacking a complete or well-annotated reference sequence set. One of the major barriers to de novo spectral interpretation arises from confusion of N- and C-terminal ion series due to the symmetry between b and y ion pairs created by collisional activation methods (or c, z ions for electron-based activation methods). This is known as the "antisymmetric path problem" and leads to inverted amino acid subsequences within a de novo reconstruction. Here, we combine several key strategies for de novo peptide sequencing into a single high-throughput pipeline: high-efficiency carbamylation blocks lysine side chains, and subsequent tryptic digestion and N-terminal peptide derivatization with the ultraviolet chromophore AMCA yield peptides susceptible to 351 nm ultraviolet photodissociation (UVPD). UVPD-MS/MS of the AMCA-modified peptides then predominantly produces y ions in the MS/MS spectra, specifically addressing the antisymmetric path problem. Finally, the program UVnovo applies a random forest algorithm to automatically learn from and then interpret UVPD mass spectra, passing results to a hidden Markov model for de novo sequence prediction and scoring. We show this combined strategy provides high-performance de novo peptide sequencing, enabling the de novo sequencing of thousands of peptides from an Escherichia coli lysate at high confidence.

  15. A Bacillus flagellar motor that can use both Na+ and K+ as a coupling ion is converted by a single mutation to use only Na+.

    Directory of Open Access Journals (Sweden)

    Naoya Terahara

    Full Text Available In bacteria, the sodium ion (Na(+ cycle plays a critical role in negotiating the challenges of an extremely alkaline and sodium-rich environment. Alkaliphilic bacteria that grow optimally at high pH values use Na(+ for solute uptake and flagellar rotation because the proton (H(+ motive force is insufficient for use at extremely alkaline pH. Only three types of electrically driven rotary motors exist in nature: the F-type ATPase, the V-type ATPase, and the bacterial flagellar motor. Until now, only H(+ and Na(+ have been reported as coupling ions for these motors. Here, we report that the alkaliphilic bacterium Bacillus alcalophilus Vedder 1934 can grow not only under a Na(+-rich and potassium ion (K(+-poor condition but also under the opposite condition in an extremely alkaline environment. In this organism, swimming performance depends on concentrations of Na(+, K(+ or Rb(+. In the absence of Na(+, swimming behavior is clearly K(+- dependent. This pattern was confirmed in swimming assays of stator-less Bacillus subtilis and Escherichia coli mutants expressing MotPS from B. alcalophilus (BA-MotPS. Furthermore, a single mutation in BA-MotS was identified that converted the naturally bi-functional BA-MotPS to stators that cannot use K(+ or Rb(+. This is the first report that describes a flagellar motor that can use K(+ and Rb(+ as coupling ions. The finding will affect the understanding of the operating principles of flagellar motors and the molecular mechanisms of ion selectivity, the field of the evolution of environmental changes and stresses, and areas of nanotechnology.

  16. A Bacillus flagellar motor that can use both Na+ and K+ as a coupling ion is converted by a single mutation to use only Na+.

    Science.gov (United States)

    Terahara, Naoya; Sano, Motohiko; Ito, Masahiro

    2012-01-01

    In bacteria, the sodium ion (Na(+)) cycle plays a critical role in negotiating the challenges of an extremely alkaline and sodium-rich environment. Alkaliphilic bacteria that grow optimally at high pH values use Na(+) for solute uptake and flagellar rotation because the proton (H(+)) motive force is insufficient for use at extremely alkaline pH. Only three types of electrically driven rotary motors exist in nature: the F-type ATPase, the V-type ATPase, and the bacterial flagellar motor. Until now, only H(+) and Na(+) have been reported as coupling ions for these motors. Here, we report that the alkaliphilic bacterium Bacillus alcalophilus Vedder 1934 can grow not only under a Na(+)-rich and potassium ion (K(+))-poor condition but also under the opposite condition in an extremely alkaline environment. In this organism, swimming performance depends on concentrations of Na(+), K(+) or Rb(+). In the absence of Na(+), swimming behavior is clearly K(+)- dependent. This pattern was confirmed in swimming assays of stator-less Bacillus subtilis and Escherichia coli mutants expressing MotPS from B. alcalophilus (BA-MotPS). Furthermore, a single mutation in BA-MotS was identified that converted the naturally bi-functional BA-MotPS to stators that cannot use K(+) or Rb(+). This is the first report that describes a flagellar motor that can use K(+) and Rb(+) as coupling ions. The finding will affect the understanding of the operating principles of flagellar motors and the molecular mechanisms of ion selectivity, the field of the evolution of environmental changes and stresses, and areas of nanotechnology.

  17. Phase transitions and multicritical points in the mixed spin-32 and spin-2 Ising system with a single-ion anisotropy

    International Nuclear Information System (INIS)

    Bobak, A.; Dely, J.

    2007-01-01

    The effect of a single-ion anisotropy on the phase diagram of the mixed spin-32 and spin-2 Ising system is investigated by the use of a mean-field theory based on the Bogoliubov inequality for the free energy. Topologically different kinds of phase diagrams are achieved by changing values of the parameter in the model Hamiltonian. Besides second-order transitions, lines of first-order transitions terminating either at a tricritical point or an isolated critical point, are found

  18. Thiol-ene synthesis and characterization of lithium bis(malonato)borate single-ion conducting gel polymer electrolytes.

    Science.gov (United States)

    Weber, Ryan L; Mahanthappa, Mahesh K

    2017-10-25

    The development of high capacity anodes and high voltage cathodes for advanced lithium-ion batteries motivates the search for new polymer electrolytes that exhibit superior electrochemical stabilities and high ionic conductivities. We report a convenient, three-step synthesis of lithium bis(non-8-enyl-malonato)borate (LiBNMB) as a α,ω-diene monomer, which undergoes thermally initiated thiol-ene crosslinking polymerizations in propylene carbonate to yield gel polymer electrolytes with high lithium ion concentrations (∼0.9 M). By conducting these crosslinking polymerizations using mixtures of di- and tri-thiols and LiBNMB with [thiol] : [ene] = 1 : 1, we synthesized a series of gel networks with dynamic elastic moduli ranging from G' = 40-79 kPa that increase monotonically with trifunctional crosslinker content. While ionic conductivities for these polymer gels measured by electrochemical impedance spectroscopy at 22 °C are σ = 0.82-2.5 × 10 -6 S cm -1 , we show that the conductivity of propylene carbonate-solvated lithium ions though the bulk of these gel electrolytes is 8.5 × 10 -5 S cm -1 independent of crosslinker density. However, the conductivities of the gel interfaces depend sensitively on crosslinker content, suggesting the importance of segmental rearrangement dynamics at the electrode interface in limiting the rate of ion motion. Thus, the design of highly conductive polymer electrolytes for advanced batteries demands careful design of both the internal and interfacial properties of these new materials.

  19. Analysis of sub-bandgap losses in TiO2 coating deposited via single and dual ion beam deposition

    Czech Academy of Sciences Publication Activity Database

    Žídek, Karel; Hlubuček, Jiří; Horodyská, Petra; Budasz, Jiří; Václavík, Jan

    2017-01-01

    Roč. 626, March (2017), s. 60-65 ISSN 0040-6090 R&D Projects: GA MŠk(CZ) LO1206 Institutional support: RVO:61389021 Keywords : Ion beam deposition * Titanium dioxide * Optical coating * Sub-bandgap losses * Urbach tail Subject RIV: BH - Optics, Masers, Lasers OBOR OECD: Optics (including laser optics and quantum optics) Impact factor: 1.879, year: 2016 http://www.sciencedirect.com/science/article/pii/S0040609017301256

  20. Single crystal silicon carbide detector of emitted ions and soft x rays from power laser-generated plasmas

    Czech Academy of Sciences Publication Activity Database

    Torrisi, L.; Foti, G.; Giuffrida, L.; Puglisi, D.; Wolowski, J.; Badziak, J.; Parys, P.; Rosinski, M.; Margarone, D.; Krása, Josef; Velyhan, Andriy; Ullschmied, Jiří

    2009-01-01

    Roč. 105, č. 12 (2009), 123304/1-123304/7 ISSN 0021-8979 R&D Projects: GA AV ČR IAA100100715 Institutional research plan: CEZ:AV0Z10100523; CEZ:AV0Z20430508 Keywords : laser-produced plasma * SiC detector * ion collector Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 2.072, year: 2009