WorldWideScience

Sample records for single intratracheal injection

  1. Intravenous and intratracheal mesenchymal stromal cell injection in a mouse model of pulmonary emphysema.

    Science.gov (United States)

    Tibboel, Jeroen; Keijzer, Richard; Reiss, Irwin; de Jongste, Johan C; Post, Martin

    2014-06-01

    The aim of this study was to characterize the evolution of lung function and -structure in elastase-induced emphysema in adult mice and the effect of mesenchymal stromal cell (MSC) administration on these parameters. Adult mice were treated with intratracheal (4.8 units/100 g bodyweight) elastase to induce emphysema. MSCs were administered intratracheally or intravenously, before or after elastase injection. Lung function measurements, histological and morphometric analysis of lung tissue were performed at 3 weeks, 5 and 10 months after elastase and at 19, 20 and 21 days following MSC administration. Elastase-treated mice showed increased dynamic compliance and total lung capacity, and reduced tissue-specific elastance and forced expiratory flows at 3 weeks after elastase, which persisted during 10 months follow-up. Histology showed heterogeneous alveolar destruction which also persisted during long-term follow-up. Jugular vein injection of MSCs before elastase inhibited deterioration of lung function but had no effects on histology. Intratracheal MSC treatment did not modify lung function or histology. In conclusion, elastase-treated mice displayed persistent characteristics of pulmonary emphysema. Jugular vein injection of MSCs prior to elastase reduced deterioration of lung function. Intratracheal MSC treatment had no effect on lung function or histology.

  2. Chronic intratracheal application of the soluble guanylyl cyclase stimulator BAY 41-8543 ameliorates experimental pulmonary hypertension.

    Science.gov (United States)

    Amirjanians, Matthieu; Egemnazarov, Bakytbek; Sydykov, Akylbek; Kojonazarov, Baktybek; Brandes, Ralf; Luitel, Himal; Pradhan, Kabita; Stasch, Johannes-Peter; Redlich, Gorden; Weissmann, Norbert; Grimminger, Friedrich; Seeger, Werner; Ghofrani, Hossein; Schermuly, Ralph

    2017-05-02

    Dysfunction of the NO/sGC/cGMP signaling pathway has been implicated in the pathogenesis of pulmonary hypertension (PH). Therefore, agents stimulating cGMP synthesis via sGC are important therapeutic options for treatment of PH patients. An unwanted effect of this novel class of drugs is their systemic hypotensive effect. We tested the hypothesis that aerosolized intra-tracheal delivery of the sGC stimulator BAY41-8543 could diminish its systemic vasodilating effect.Pharmacodynamics and -kinetics of BAY41-8543 after single intra-tracheal delivery was tested in healthy rats. Four weeks after a single injection of monocrotaline (MCT, 60 mg/kg s.c.), rats were randomized to a two-week treatment with either placebo, BAY 41-8543 (10 mg/kg per os (PO)) or intra-tracheal (IT) instillation (3 mg/kg or 1 mg/kg).Circulating concentrations of the drug 10 mg/kg PO and 3 mg/kg IT were comparable. BAY 41-8543 was detected in the lung tissue and broncho-alveolar fluid after IT delivery at higher concentrations than after PO administration. Systemic arterial pressure transiently decreased after oral BAY 41-8543 and was unaffected by intratracheal instillation of the drug. PO 10 mg/kg and IT 3 mg/kg regimens partially reversed pulmonary hypertension and improved heart function in MCT-injected rats. Minor efficacy was noted in rats treated IT with 1 mg/kg. The degree of pulmonary vascular remodeling was largely reversed in all treatment groups.Intratracheal administration of BAY 41-8543 reverses PAH and vascular structural remodeling in MCT-treated rats. Local lung delivery is not associated with systemic blood pressure lowering and represents thus a further development of PH treatment with sGC stimulators.

  3. Single-walled carbon nanotubes disturbed the immune and metabolic regulation function 13-weeks after a single intratracheal instillation

    Energy Technology Data Exchange (ETDEWEB)

    Park, Eun-Jung, E-mail: pejtoxic@hanmail.net [Myunggok Eye Research Institute, Konyang University, Daejeon 302-718 (Korea, Republic of); Hong, Young-Shick [Division of Food and Nutrition, Chonnam National University, Yongbong-Ro, Buk-Gu, Gwangju 500-757 (Korea, Republic of); Lee, Byoung-Seok [Toxicologic Pathology Center, Korea Institute of Toxicology, Daejeon (Korea, Republic of); Yoon, Cheolho [Seoul Center, Korea Basic Science Institute, Seoul 126-16 (Korea, Republic of); Jeong, Uiseok; Kim, Younghun [Department of Chemical Engineering, Kwangwoon University, Seoul 139-701 (Korea, Republic of)

    2016-07-15

    Due to their unique physicochemical properties, the potential health effects of single-walled carbon nanotubes (SWCNTs) have attracted continuous attention together with their extensive application. In this study, we aimed to identify local and systemic health effects following pulmonary persistence of SWCNTs. As expected, SWCNTs remained in the lung for 13 weeks after a single intratracheal instillation (50, 100, and 200 μg/kg). In the lung, the total number of cells and the percentages of lymphocytes and neutrophils significantly increased at 200 μg/kg compared to the control, and the Th1-polarized immune response was induced accompanying enhanced expression of tissue damage-related genes and increased release of chemokines. Additionally, SWCNTs enhanced the expression of antigen presentation-related proteins on the surface of antigen-presenting cells, however, maturation of dendritic cells was inhibited by their persistence. As compared to the control, a significant increase in the percentage of neutrophils and a remarkable decrease of BUN and potassium level were observed in the blood of mice treated with the highest dose. This was accompanied by the down-regulation of the expression of antigen presentation-related proteins on splenocytes. Moreover, protein and glucose metabolism were disturbed with an up-regulation of fatty acid β-oxidation. Taken together, we conclude that SWCNTs may induce adverse health effects by disturbing immune and metabolic regulation functions in the body. Therefore, careful application of SWCNTs is necessary for the enforcement of safety in nano-industries. - Highlights: • We evaluated local and systemic health effects following persistence of SWCNTs. • SWCNTs remained in the lung for 13 weeks after a single intratracheal instillation. • Th1-polarized immune response was induced in the lung. • The expression of antigen presentation-related proteins was altered. • Immune and metabolic regulation function were disturbed.

  4. Induction of lung cancer in rats by intratracheal insufflation of carcinogenic hydrocarbons

    Energy Technology Data Exchange (ETDEWEB)

    Pylev, L N

    1963-01-01

    One, 3, or 5 monthly intratracheal injections of 2 to 2.5 mg dimethylbenzanthracene (DMBA) in India ink-solvent or 5 or 7 monthly injections of 5 mg benzyprene (BaP) in India ink-solvent into rats produced tumors, starting at 5 months, mostly around accumulations of ink. Results showed 27.8% of 151 animals receiving DMBA and surviving to 5 months developed carcinomas, as compared to 7 of 12 animals receiving BaP.

  5. Inflammogenic effect of well-characterized fullerenes in inhalation and intratracheal instillation studies

    Directory of Open Access Journals (Sweden)

    Yamamoto Kazuhiro

    2010-03-01

    Full Text Available Abstract Background We used fullerenes, whose dispersion at the nano-level was stabilized by grinding in nitrogen gas in an agitation mill, to conduct an intratracheal instillation study and an inhalation exposure study. Fullerenes were individually dispersed in distilled water including 0.1% Tween 80, and the diameter of the fullerenes was 33 nm. These suspensions were directly injected as a solution in the intratracheal instillation study. The reference material was nickel oxide in distilled water. Wistar male rats intratracheally received a dose of 0.1 mg, 0.2 mg, or 1 mg of fullerenes and were sacrificed after 3 days, 1 week, 1 month, 3 months, and 6 months. In the inhalation study, Wistar rats were exposed to fullerene agglomerates (diameter: 96 ± 5 nm; 0.12 ± 0.03 mg/m3; 6 hours/days for 5 days/week for 4 weeks and were sacrificed at 3 days, 1 month, and 3 months after the end of exposure. The inflammatory responses and gene expression of cytokine-induced neutrophil chemoattractants (CINCs were examined in rat lungs in both studies. Results In the intratracheal instillation study, both the 0.1 mg and 0.2 mg fullerene groups did not show a significant increase of the total cell and neutrophil count in BALF or in the expression of CINC-1,-2αβ and-3 in the lung, while the high-dose, 1 mg group only showed a transient significant increase of neutrophils and expression of CINC-1,-2αβ and -3. In the inhalation study, there were no increases of total cell and neutrophil count in BALF, CINC-1,-2αβ and-3 in the fullerene group. Conclusion These data in intratracheal instillation and inhalation studies suggested that well-dispersed fullerenes do not have strong potential of neutrophil inflammation.

  6. Intratracheal injection of adenovirus containing the human MNSOD transgene protects athymic nude mice from irradiation-induced organizing alveolitis

    International Nuclear Information System (INIS)

    Epperly, Michael W.; Bray, Jenifer A.; Krager, Stephen; Berry, Luann M.; Gooding, William; Engelhardt, John F.; Zwacka, Ralf; Travis, Elizabeth L.; Greenberger, Joel S.

    1999-01-01

    Purpose: A dose and volume limiting factor in radiation treatment of thoracic cancer is the development of fibrosis in normal lung. The goal of the present study was to determine whether expression prior to irradiation of a transgene for human manganese superoxide dismutase (MnSOD) or human copper/zinc superoxide dismutase (Cu/ZnSOD) protects against irradiation-induced lung damage in mice. Methods and Materials: Athymic Nude (Nu/J) mice were intratracheally injected with 10 9 plaque-forming units (PFU) of a replication-incompetent mutant adenovirus construct containing the gene for either human MnSOD, human copper/zinc superoxide dismutase (Cu/ZnSOD) or LacZ. Four days later the mice were irradiated to the pulmonary cavity to doses of 850, 900, or 950 cGy. To demonstrate adenoviral infection, nested reverse transcriptase-polymerase chain reaction (RT-PCR) was carried out with primers specific for either human MnSOD or Cu/ZnSOD transgene on freshly explanted lung, trachea, or alveolar type II cells, and immunohistochemistry was used to measure LacZ expression. RNA was extracted on day 0, 1, 4, or 7 after 850 cGy of irradiation from lungs of mice that had previously received adenovirus or had no treatment. Slot blot analysis was performed to quantitate RNA expression for IL-1, tumor necrosis factor (TNF)-α, TGF-β, MnSOD, or Cu/ZnSOD. Lung tissue was explanted and tested for biochemical activity of MnSOD or Cu/ZnSOD after adenovirus injection. Other mice were sacrificed 132 days after irradiation, lungs excised, frozen in OCT, (polyvinyl alcohol, polyethylene glycol mixture) sectioned, H and E stained, and evaluated for percent of the lung demonstrating organizing alveolitis. Results: Mice injected intratracheally with adenovirus containing the gene for human MnSOD had significantly reduced chronic lung irradiation damage following 950 cGy, compared to control mice or mice injected with adenovirus containing the gene for human Cu/ZnSOD or LacZ. Immunohistochemistry

  7. Intratracheal administration of bacterial lipopolysaccharide elicits pulmonary hypertension in broilers with primed airways.

    Science.gov (United States)

    Lorenzoni, A G; Wideman, R F

    2008-04-01

    Broilers reared under commercial conditions inhale irritant gases and aerosolized particulates contaminated with gram-negative bacteria and bacterial lipopolysaccharide (LPS). Previous studies demonstrated that i.v. injections of LPS can trigger an increase in the pulmonary arterial pressure (PAP); however, the pulmonary hemodynamic response to aerosolized LPS entering via the most common route, the respiratory tract, had not been evaluated in broilers. In experiment 1, broilers reared on new wood shavings litter in clean environmental chambers either were not pretreated (control group) or were pretreated via aerosol inhalation of substances (food color dyes and propylene glycol) known to sensitize the airways. One day later, the broilers were anesthetized, catheterized to record the PAP, and an intratracheal aerosol spray of LPS (1 mL of 2 mg/mL of LPS) was administered. Broilers in the control group as well as broilers pretreated with aerosolized distilled water or yellow and blue food color dyes did not develop pulmonary hypertension (PH; an increase in PAP) after the intratracheal spray of LPS, whereas broilers that had been pretreated with red food color did develop PH in response to intratracheal LPS. In experiment 2, birds raised under commercial conditions on used wood shavings litter developed PH in response to intratracheal LPS regardless of whether they had been pretreated with aerosolized red food color dye. In experiment 3, broilers reared in clean environmental chambers on new wood shavings litter were used to demonstrate that Red Dye #3 and propylene glycol are capable of priming the responsiveness of the airways to a subsequent intratracheal LPS challenge. Common air contaminants such as LPS can result in PH leading to pulmonary hypertension syndrome (ascites) in broilers with appropriately primed airways.

  8. Intratracheal Seal Disc

    DEFF Research Database (Denmark)

    Christiansen, Karen J; Moeslund, Niels; Lauridsen, Henrik

    2017-01-01

    . The device consisted of an intratracheal silicone seal disc fixated by a cord through the stoma to an external part. At day 14, computed tomography (CT) was performed before the device was extracted. With the pulling of a cord, the disc unraveled into a thin thread and was extracted through the stoma. At day...

  9. Intratracheal synthetic CpG oligodeoxynucleotide causes acute lung injury with systemic inflammatory response

    Directory of Open Access Journals (Sweden)

    Hasegawa Naoki

    2009-09-01

    Full Text Available Abstract Bacterial genome is characterized by frequent unmethylated cytosine-phosphate-guanine (CpG motifs. Deleterious effects can occur when synthetic oligodeoxynucleotides (ODN with unmethylated CpG dinucleotides (CpG-ODN are administered in a systemic fashion. We aimed to evaluate the effect of intratracheal CpG-ODN on lung inflammation and systemic inflammatory response. C57BL/6J mice received intratracheal administration of CpG-ODN (0.01, 0.1, 1.0, 10, or 100 μM or control ODN without CpG motif. Bronchoalveolar lavage (BAL fluid was obtained 3 or 6 h or 1, 2, 7, or 14 days after the instillation and subjected to a differential cell count and cytokine measurement. Lung permeability was evaluated as the BAL fluid-to-plasma ratio of the concentration of human serum albumin that was injected 1 h before euthanasia. Nuclear factor (NF-κB DNA binding activity was also evaluated in lung homogenates. Intratracheal administration of 10 μM or higher concentration of CpG-ODN induced significant inflammatory cell accumulation into the airspace. The peak accumulation of neutrophils and lymphocytes occurred 1 and 2 days after the CpG-ODN administration, respectively. Lung permeability was increased 1 day after the 10 μM CpG-ODN challenge. CpG-ODN also induced nuclear translocation of NF-κB and upregulation of various inflammatory cytokines in BAL fluid and plasma. Histopathology of the lungs and liver revealed acute lung injury and liver damage with necrosis, respectively. Control ODN without CpG motif did not induce any inflammatory change. Since intratracheal CpG-ODN induced acute lung injury as well as systemic inflammatory response, therapeutic strategies to neutralize bacterial DNA that is released after administration of bactericidal agents should be considered.

  10. Toxicokinetics of hexavalent chromium in the rat after intratracheal administration of chromates of different solubilities

    NARCIS (Netherlands)

    Bragt, P.C.; Dura, E.A. van

    1983-01-01

    The kinetics of chromium in the rat after a single intratracheal dose of sodium, zinc or lead 51Cr-chromate have been investigated. Sodium chromate and the less soluble zinc chromate were absorbed into the blood and this resulted in increased excretion of chromium into the urine. The insoluble lead

  11. Significance of Intratracheal Instillation Tests for the Screening of Pulmonary Toxicity of Nanomaterials.

    Science.gov (United States)

    Morimoto, Yasuo; Izumi, Hiroto; Yoshiura, Yukiko; Fujisawa, Yuri; Fujita, Katsuhide

    Inhalation tests are the gold standard test for the estimation of the pulmonary toxicity of respirable materials. Intratracheal instillation tests have been used widely, but they yield limited evidence of the harmful effects of respirable materials. We reviewed the effectiveness of intratracheal instillation tests for estimating the hazards of nanomaterials, mainly using research papers featuring intratracheal instillation and inhalation tests centered on a Japanese national project. Compared to inhalation tests, intratracheal instillation tests induced more acute inflammatory responses in the animal lung due to a bolus effect regardless of the toxicity of the nanomaterials. However, nanomaterials with high toxicity induced persistent inflammation in the chronic phase, and nanomaterials with low toxicity induced only transient inflammation. Therefore, in order to estimate the harmful effects of a nanomaterial, an observation period of 3 months or 6 months following intratracheal instillation is necessary. Among the endpoints of pulmonary toxicity, cell count and percentage of neutrophil, chemokines for neutrophils and macrophages, and oxidative stress markers are considered most important. These markers show persistent and transient responses in the lung from nanomaterials with high and low toxicity, respectively. If the evaluation of the pulmonary toxicity of nanomaterials is performed in not only the acute but also the chronic phase in order to avoid the bolus effect of intratracheal instillation and inflammatory-related factors that are used as endpoints of pulmonary toxicity, we speculate that intratracheal instillation tests can be useful for screening for the identification of the hazard of nanomaterials through pulmonary inflammation.

  12. Effect of intratracheally instilled depleted uranium on immunological function of rats

    International Nuclear Information System (INIS)

    You Hanhu; Yang Zhihua; Cao Zhenshan; Zhu Maoxiang; Liu Xingrong

    2004-01-01

    Objective: To study immunological effects of depleted uranium in rats. Methods: Wistar rats were exposed to depleted uranium by single intratracheal instillation. Body weight and peripheral blood cells were measured weekly and immunological functions were evaluated by weight coefficient of immune organs, plague forming cells of splenocytes, total and subpopulation counts of lymphocytes in thymus. Results: Early after administration, body weight decreased and red blood cells as well as platelets reduced while white blood cells increased, which returned to normal within 1 or 2 months. Immunological functions of splenocytes and thymocytes were affected dose-dependently by depleted uranium. Conclusion: Depleted uranium induces immunological dysfunction in rats. (authors)

  13. Cost-Utility of a Single-Injection Combined Corticosteroid-Hyaluronic Acid Formulation vs a 2-Injection Regimen of Sequential Corticosteroid and Hyaluronic Acid Injections.

    Science.gov (United States)

    Belzile, Etienne L; Deakon, Robert T; Vannabouathong, Christopher; Bhandari, Mohit; Lamontagne, Martin; McCormack, Robert

    2017-01-01

    Research has shown early and sustained relief with a combination therapy of a corticosteroid (CS) and hyaluronic acid (HA) in knee osteoarthritis (OA) patients. This can be administered via a single injection containing both products or as separate injections. The former may be more expensive when considering only product cost, but the latter incurs the additional costs and time of a second procedure. The purpose of this study was to compare the cost-utility of the single injection with the 2-injection regimen. The results of this analysis revealed that the single-injection formulation of a CS and HA may be cost-effective, assuming a willingness-to-pay of $50 000 per quality-adjusted life year gained, for symptomatic relief of OA symptoms. This treatment may also be more desirable to patients who find injections to be inconvenient or unpleasant.

  14. Voltage controlled nano-injection system for single-cell surgery

    Science.gov (United States)

    Seger, R. Adam; Actis, Paolo; Penfold, Catherine; Maalouf, Michelle; Vilozny, Boaz; Pourmand, Nader

    2015-01-01

    Manipulation and analysis of single cells is the next frontier in understanding processes that control the function and fate of cells. Herein we describe a single-cell injection platform based on nanopipettes. The system uses scanning microscopy techniques to detect cell surfaces, and voltage pulses to deliver molecules into individual cells. As a proof of concept, we injected adherent mammalian cells with fluorescent dyes. PMID:22899383

  15. Two injection digital block versus single subcutaneous palmar injection block for finger lacerations.

    Science.gov (United States)

    Okur, O M; Şener, A; Kavakli, H Ş; Çelik, G K; Doğan, N Ö; Içme, F; Günaydin, G P

    2017-12-01

    We aimed to compare two digital nerve block techniques in patients due to traumatic digital lacerations. This was a randomized-controlled study designed prospectively in the emergency department of a university-based training and research hospital. Randomization was achieved by sealed envelopes. Half of the patients were randomised to traditional (two-injection) digital nerve block technique while single-injection digital nerve block technique was applied to the other half. Score of pain due to anesthetic infiltration and suturing, onset time of total anesthesia, need for an additional rescue injection were the parameters evaluated with both groups. Epinephrin added lidocaine hydrochloride preparation was used for the anesthetic application. Visual analog scale was used for the evaluation of pain scores. Outcomes were compared by using Mann-Whitney U test and Student t-test. Fifty emergency department patients ≥18 years requiring digital nerve block were enrolled in the study. Mean age of the patients was 33 (min-max: 19-86) and 39 (78 %) were male. No statistically significant difference was found between the two groups in terms of our main parameters; anesthesia pain score, suturing pain score, onset time of total anesthesia and rescue injection need. Single injection volar digital nerve block technique is a suitable alternative for digital anesthesias in emergency departments.

  16. Enhanced bioavailability of opiates after intratracheal administration

    International Nuclear Information System (INIS)

    Findlay, J.W.A.; Jones, E.C.; McNulty, M.J.

    1986-01-01

    Several opiate analgesics have low oral bioavailabilities in the dog because of presystemic metabolism. Intratracheal administration may circumvent this first-pass effect. Three anesthetized beagles received 5-mg/kg doses of codeine phosphate intratracheally (i.t.), orally (p.o.) and intravenously (i.v.) in a crossover study. The following drugs were also studied in similar experiments: ethylmorphine hydrochloride (5 mg/kg), pholcodine bitartrate (10 mg/kg, hydrocodone bitartrate (4 mg/kg) and morphine sulfate (2.5 mg/kg). Plasma drug concentrations over the 24- to 48-hr periods after drug administrations were determined by radioimmunoassays. I.t. bioavailabilities [codeine (84%), ethylmorphine (100%), and morphine (87%)] of drugs with poor oral availabilities were all markedly higher than the corresponding oral values (14, 26, and 23%, respectively). I.t. bioavailabilities of pholcodine (93%) and hydrocodone (92%), which have good oral availabilities (74 and 79%, respectively), were also enhanced. In all cases, peak plasma concentrations occurred more rapidly after i.t. (0.08-0.17 hr) than after oral (0.5-2 hr) dosing and i.t. disposition often resembled i.v. kinetics. I.t. administration may be a valuable alternative dosing route, providing rapid onset of pharmacological activity for potent drugs with poor oral bioavailability

  17. Single-needle temporomandibular joint arthrocentesis with hyaluronic acid injections. Preliminary data after a five-injection protocol.

    Science.gov (United States)

    Manfredini, D; Guarda-Nardini, L; Ferronato, G

    2009-10-01

    The classical technique for temporomandibular joint (TMJ) arthrocentesis provides a double access to the joint space, which may lead to patient's postoperatory discomfort. For this reason, a less invasive, single-needle approach has been recently described, and the present investigation reports findings on a case series of patients with TMJ osteoarthritis treated with hyaluronic acid injections following a single needle arthrocentesis. METHODS. Fourteen consecutive patients with a diagnosis of TMJ osteoarthritis according to the Research Diagnostic Criteria for Temporo-mandibular Disorders were treated with a cycle of five weekly injections of hyaluronic acid after arthrocentesis. A number of subjective (pain at rest and mastication, masticatory efficiency, functional limitation, subjective efficacy of treatment, tolerability of treatment) and objective (maximum assisted and unassited mouth opening, protrusive and laterotrusive movements) outcome variables were assessed before and after the treatment period. At the end of the five-injection protocol, significant improvements were showed in almost all the subjective outcome variables. Tolerability of the treatment was good on a four-point ordinal scale since the time of the first injection. The present investigation suggested that the single needle technique for TMJ hyaluronic injection following arthrocentesis in osteoarthritic joints may have promising applications in the clinical setting, which have to be confirmed with future studies.

  18. Ultrasound-Guided Single-Injection Infraclavicular Block Versus Ultrasound-Guided Double-Injection Axillary Block: A Noninferiority Randomized Controlled Trial.

    Science.gov (United States)

    Boivin, Ariane; Nadeau, Marie-Josée; Dion, Nicolas; Lévesque, Simon; Nicole, Pierre C; Turgeon, Alexis F

    2016-01-01

    Single-injection ultrasound-guided infraclavicular block is a simple, reliable, and effective technique. A simplified double-injection ultrasound-guided axillary block technique with a high success rate recently has been described. It has the advantage of being performed in a superficial and compressible location, with a potentially improved safety profile. However, its effectiveness in comparison with single-injection infraclavicular block has not been established. We hypothesized that the double-injection ultrasound-guided axillary block would show rates of complete sensory block at 30 minutes noninferior to the single-injection ultrasound-guided infraclavicular block. After approval by our research ethics committee and written informed consent, adults undergoing distal upper arm surgery were randomized to either group I, ultrasound-guided single-injection infraclavicular block, or group A, ultrasound-guided double-injection axillary block. In group I, 30 mL of 1.5% mepivacaine was injected posterior to the axillary artery. In group A, 25 mL of 1.5% mepivacaine was injected posteromedial to the axillary artery, after which 5 mL was injected around the musculocutaneous nerve. Primary outcome was the rate of complete sensory block at 30 minutes. Secondary outcomes were the onset of sensory and motor blocks, surgical success rates, performance times, and incidence of complications. All outcomes were assessed by a blinded investigator. The noninferiority of the double-injection ultrasound-guided axillary block was considered if the limits of the 90% confidence intervals (CIs) were within a 10% margin of the rate of complete sensory block of the infraclavicular block. At 30 minutes, the rate of complete sensory block was 79% in group A (90% CI, 71%-85%) compared with 91% in group I (90% CI, 85%-95%); the upper limit of CI of group A is thus included in the established noninferiority margin of 10%. The rate of complete sensory block was lower in group A (proportion

  19. Efficacy of a single ultrasound-guided injection for the treatment of hip osteoarthritis.

    LENUS (Irish Health Repository)

    Atchia, Ismaël

    2011-01-01

    Intra-articular injection is effective for osteoarthritis, but the best single injection strategy is not known, nor are there established predictors of response. The objectives of this study were to assess and predict response to a single ultrasound-guided injection in moderate to severe hip osteoarthritis.

  20. Acute Pathophysiological Effects of Intratracheal Instillation of Budesonide and Exogenous Surfactant in a Neonatal Surfactant-depleted Piglet Model

    Directory of Open Access Journals (Sweden)

    Chia-Feng Yang

    2010-08-01

    Conclusions: Intratracheal instillation of surfactant or surfactant plus budesonide can improve oxygenation and pulmonary histologic outcome in neonatal surfactant-depleted lungs. The additional use of budesonide does not disturb the function of the exogenous surfactant. Intratracheal administration of a corticosteroid combined with surfactant may be an effective method for alleviating local pulmonary inflammation in severe RDS.

  1. Pulmonary toxicity of well-dispersed cerium oxide nanoparticles following intratracheal instillation and inhalation

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, Yasuo, E-mail: yasuom@med.uoeh-u.ac.jp; Izumi, Hiroto; Yoshiura, Yukiko; Tomonaga, Taisuke; Oyabu, Takako; Myojo, Toshihiko; Kawai, Kazuaki; Yatera, Kazuhiro [University of Occupational and Environmental Health (Japan); Shimada, Manabu; Kubo, Masaru [Hiroshima University (Japan); Yamamoto, Kazuhiro [National Institute of Advanced Industrial Science and Technology (AIST) (Japan); Kitajima, Shinichi [National Sanatorium Hoshizuka Keiaien (Japan); Kuroda, Etsushi [Osaka University, Laboratory of Vaccine Science, WPI Immunology Frontier Research Center (Japan); Kawaguchi, Kenji; Sasaki, Takeshi [National Institute of Advanced Industrial Science and Technology (AIST) (Japan)

    2015-11-15

    We performed inhalation and intratracheal instillation studies of cerium dioxide (CeO{sub 2}) nanoparticles in order to investigate their pulmonary toxicity, and observed pulmonary inflammation not only in the acute and but also in the chronic phases. In the intratracheal instillation study, F344 rats were exposed to 0.2 mg or 1 mg of CeO{sub 2} nanoparticles. Cell analysis and chemokines in bronchoalveolar lavage fluid (BALF) were analyzed from 3 days to 6 months following the instillation. In the inhalation study, rats were exposed to the maximum concentration of inhaled CeO{sub 2} nanoparticles (2, 10 mg/m{sup 3}, respectively) for 4 weeks (6 h/day, 5 days/week). The same endpoints as in the intratracheal instillation study were examined from 3 days to 3 months after the end of the exposure. The intratracheal instillation of CeO{sub 2} nanoparticles caused a persistent increase in the total and neutrophil number in BALF and in the concentration of cytokine-induced neutrophil chemoattractant (CINC)-1, CINC-2, chemokine for neutrophil, and heme oxygenase-1 (HO-1), an oxidative stress marker, in BALF during the observation time. The inhalation of CeO{sub 2} nanoparticles also induced a persistent influx of neutrophils and expression of CINC-1, CINC-2, and HO-1 in BALF. Pathological features revealed that inflammatory cells, including macrophages and neutrophils, invaded the alveolar space in both studies. Taken together, the CeO{sub 2} nanoparticles induced not only acute but also chronic inflammation in the lung, suggesting that CeO{sub 2} nanoparticles have a pulmonary toxicity that can lead to irreversible lesions.

  2. Increasing energy efficiency of a gasoline direct injection engine through optimal synchronization of single or double injection strategies

    International Nuclear Information System (INIS)

    Costa, Michela; Sorge, Ugo; Allocca, Luigi

    2012-01-01

    Highlights: ► Advantages of split injection in a GDI engine are studied through numerical simulation. ► At high load and speed, rich conditions, split injection does not improve engine performance. ► At moderate load and speed, lean conditions, double injection improves charge stratification. ► Optimal double injection increases work, reduces HC and increases NO. - Abstract: The greatest fuel efficiency advantages of gasoline direct injection (GDI) engines are achieved under the so-called mixed mode boosting, where mixture characteristics are properly adapted to the specific working condition. In particular, in the medium range of load and speed, overall lean mixtures are suitable of being used in the so-called direct injection stratified charge operation. Present paper reports the results of numerical optimization analyses aimed at increasing the energetic efficiency of a GDI engine equipped with a high pressure multi-hole injector under both single and double injection events. In moderate-load moderate-speed lean conditions, the single or double injection synchronization in the working cycle is effected through a procedure that couples a 3D numerical model of the in-cylinder processes with an optimization tool. The choice of both the start of the injection events and the time of spark advance is realized to maximize the engine work. The optimal double injection solution is shown to increase the engine energy efficiency with respect to the case injection is realized in one shot, thus confirming that split injections improve the quality of the charge stratification under lean operation. The effect on the major pollutants is also discussed.

  3. Pulmonary toxicity of well-dispersed titanium dioxide nanoparticles following intratracheal instillation

    International Nuclear Information System (INIS)

    Yoshiura, Yukiko; Izumi, Hiroto; Oyabu, Takako; Hashiba, Masayoshi; Kambara, Tatsunori; Mizuguchi, Yohei; Lee, Byeong Woo; Okada, Takami; Tomonaga, Taisuke; Myojo, Toshihiko; Yamamoto, Kazuhiro; Kitajima, Shinichi; Horie, Masanori; Kuroda, Etsushi; Morimoto, Yasuo

    2015-01-01

    In order to investigate the pulmonary toxicity of titanium dioxide (TiO 2 ) nanoparticles, we performed an intratracheal instillation study with rats of well-dispersed TiO 2 nanoparticles and examined the pulmonary inflammation and histopathological changes in the lung. Wistar Hannover rats were intratracheally administered 0.2 mg (0.66 mg/kg) and 1.0 mg (3.3 mg/kg) of well-dispersed TiO 2 nanoparticles (P90; diameter of agglomerates: 25 nm), then the pulmonary inflammation responses were examined from 3 days to 6 months after the instillation, and the pathological features were examined up to 24 months. Transient inflammation and the upregulation of chemokines in the broncho-alveolar lavage fluid were observed for 1 month. No respiratory tumors or severe fibrosis were observed during the recovery time. These data suggest that transient inflammation induced by TiO 2 may not lead to chronic, irreversible legions in the lung, and that TiO 2 nanoparticles may not have a high potential for lung disorder

  4. Pulmonary toxicity of well-dispersed titanium dioxide nanoparticles following intratracheal instillation

    Energy Technology Data Exchange (ETDEWEB)

    Yoshiura, Yukiko, E-mail: y-yoshiura@med.uoeh-u.ac.jp; Izumi, Hiroto [University of Occupational and Environmental Health, Department of Occupational Pneumology, Institute of Industrial Ecological Science (Japan); Oyabu, Takako [University of Occupational and Environmental Health, Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences (Japan); Hashiba, Masayoshi; Kambara, Tatsunori [University of Occupational and Environmental Health, Department of Occupational Pneumology, Institute of Industrial Ecological Science (Japan); Mizuguchi, Yohei; Lee, Byeong Woo; Okada, Takami [University of Occupational and Environmental Health, Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences (Japan); Tomonaga, Taisuke [University of Occupational and Environmental Health, Department of Occupational Pneumology, Institute of Industrial Ecological Science (Japan); Myojo, Toshihiko [University of Occupational and Environmental Health, Department of Environmental Health Engineering, Institute of Industrial Ecological Sciences (Japan); Yamamoto, Kazuhiro [National Institute of Advanced Industrial Science and Technology (AIST) (Japan); Kitajima, Shinichi [National Sanatorium Hoshizuka Keiaien (Japan); Horie, Masanori [National Institute of Advanced Industrial Science and Technology (AIST), Health Research Institute (HRI) (Japan); Kuroda, Etsushi [Osaka University, Laboratory of Vaccine Science, WPI Immunology Frontier Research Center (Japan); Morimoto, Yasuo [University of Occupational and Environmental Health, Department of Occupational Pneumology, Institute of Industrial Ecological Science (Japan)

    2015-06-15

    In order to investigate the pulmonary toxicity of titanium dioxide (TiO{sub 2}) nanoparticles, we performed an intratracheal instillation study with rats of well-dispersed TiO{sub 2} nanoparticles and examined the pulmonary inflammation and histopathological changes in the lung. Wistar Hannover rats were intratracheally administered 0.2 mg (0.66 mg/kg) and 1.0 mg (3.3 mg/kg) of well-dispersed TiO{sub 2} nanoparticles (P90; diameter of agglomerates: 25 nm), then the pulmonary inflammation responses were examined from 3 days to 6 months after the instillation, and the pathological features were examined up to 24 months. Transient inflammation and the upregulation of chemokines in the broncho-alveolar lavage fluid were observed for 1 month. No respiratory tumors or severe fibrosis were observed during the recovery time. These data suggest that transient inflammation induced by TiO{sub 2} may not lead to chronic, irreversible legions in the lung, and that TiO{sub 2} nanoparticles may not have a high potential for lung disorder.

  5. Effects of Lignocaine Administered Intravenously or Intratracheally on Airway and Hemodynamic Responses during Emergence and Extubation in Patients Undergoing Elective Craniotomies in Supine Position.

    Science.gov (United States)

    Shabnum, Tabasum; Ali, Zulfiqar; Naqash, Imtiaz Ahmad; Mir, Aabid Hussain; Azhar, Khan; Zahoor, Syed Amer; Mir, Abdul Waheed

    2017-01-01

    Sympathoadrenergic responses during emergence and extubation can lead to an increase in heart rate (HR) and blood pressure whereas increased airway responses may lead to coughing and laryngospasm. The aim of our study was to compare the effects of lignocaine administered intravenously (IV) or intratracheally on airway and hemodynamic responses during emergence and extubation in patients undergoing elective craniotomies. Sixty patients with physical status American Society of Anaesthesiologists Classes I and II aged 18-70 years, scheduled to undergo elective craniotomies were included. The patients were randomly divided into three groups of twenty patients; Group 1 receiving IV lignocaine and intratracheal placebo (IV group), Group 2 receiving intratracheal lignocaine and IV placebo (I/T group), and Group 3 receiving IV and intratracheal placebo (placebo group). The tolerance to the endotracheal tube was monitored, and number of episodes of cough was recorded during emergence and at the time of extubation. Hemodynamic parameters such as HR and blood pressure (systolic, diastolic, mean arterial pressure) were also recorded. There was a decrease of HR in both IV and intratracheal groups in comparison with placebo group ( P < 0.005). Rise in blood pressure (systolic blood pressure, diastolic blood pressure and mean arterial pressure) was comparable in both Groups 1 and 2 but was lower in comparison with placebo group ( P < 0.005). Cough suppression was comparable in all the three groups. Grade III cough (15%) was documented only in placebo group. Both IV and intratracheal lignocaine are effective in attenuation of hemodynamic response if given within 20 min from skull pin removal to extubation. There was comparable cough suppression through intratracheal route and IV routes than the placebo group.

  6. Amplitude Noise Suppression and Orthogonal Multiplexing Using Injection-Locked Single-Mode VCSEL

    DEFF Research Database (Denmark)

    Lyubopytov, Vladimir; von Lerber, Tuomo; Lassas, Matti

    2017-01-01

    We experimentally demonstrate BER reduction and orthogonal modulation using an injection locked single-mode VCSEL. It allows us suppressing an amplitude noise of optical signal and/or double the capacity of an information channel.......We experimentally demonstrate BER reduction and orthogonal modulation using an injection locked single-mode VCSEL. It allows us suppressing an amplitude noise of optical signal and/or double the capacity of an information channel....

  7. Cluster endophthalmitis following multiple intravitreal bevacizumab injections from a single use vial

    Directory of Open Access Journals (Sweden)

    Perwez Khan

    2016-01-01

    Full Text Available The risk of endophthalmitis is always a concern when an intraocular procedure is performed. Intravitreal injection is a frequently used method for therapeutic management of many diseases, affecting the posterior segment of the eye. Hence, it is important to assess the risk of complications, especially endophthalmitis. Most studies conducted concentrate on risk assessment from single use from single drug vial. The present article reports the occurrence of cluster endophthalmitis following multiple intravitreal bevacizumab injections from a single vial. Intravitreal injection of bevacizumab was administered to eight eyes of eight patients. Administered dose was prepared from single 4-ml vial of bevacizumab and was injected in the eye, after patient preparation and under aseptic conditions. The procedure was repeated for the remaining patients, thereby imparting multiple pricks in the same vial. Four of the eight patients reported to the hospital on the 3rd day after injection with complaints of pain, watering, and diminution of vision. Two patients reported the following day with similar complaints. Two patients who did not report by the 4th day were contacted and recalled for an examination. All the patients were thoroughly examined using slit lamp biomicroscopy and indirect ophthalmoscopy. Six out of eight were clinically diagnosed to have endophthalmitis and were administered intravitreal antibiotics. The present report highlights possibility of microbial contamination of the drug vial or during compounding process. However, from the present incident, we are encouraged to stay vigilant and wary of contamination

  8. Intratracheal Milrinone Bolus Administration During Acute Right Ventricular Dysfunction After Cardiopulmonary Bypass.

    Science.gov (United States)

    Gebhard, Caroline Eva; Desjardins, Georges; Gebhard, Cathérine; Gavra, Paul; Denault, André Y

    2017-04-01

    To evaluate intratracheal milrinone (tMil) administration for rapid treatment of right ventricular (RV) dysfunction as a novel route after cardiopulmonary bypass. Retrospective analysis. Single-center study. The study comprised 7 patients undergoing cardiac surgery who exhibited acute RV dysfunction after cardiopulmonary bypass. After difficult weaning caused by cardiopulmonary bypass-induced acute RV dysfunction, milrinone was administered as a 5-mg bolus inside the endotracheal tube. RV function improvement, as indicated by decreasing pulmonary artery pressure and changes of RV waveforms, was observed in all 7 patients. Adverse effects of tMil included dynamic RV outflow tract obstruction (2 patients) and a decrease in systemic mean arterial pressure (1 patient). tMil may be an effective, rapid, and easily applicable therapeutic alternative to inhaled milrinone for the treatment of acute RV failure during cardiac surgery. However, sufficiently powered clinical trials are needed to confirm these findings. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Carbon black nanoparticles induce biphasic gene expression changes associated with inflammatory responses in the lungs of C57BL/6 mice following a single intratracheal instillation

    DEFF Research Database (Denmark)

    Husain, Mainul; Kyjovska, Zdenka O.; Bourdon-Lacombe, Julie

    2015-01-01

    Inhalation of carbon black nanoparticles (CBNPs) causes pulmonary inflammation; however, time course data to evaluate the detailed evolution of lung inflammatory responses are lacking. Here we establish a time-series of lung inflammatory response to CBNPs. Female C57BL/6 mice were intratracheally...... to nine 8-h working days at the current Danish occupational exposure limit induced biphasic inflammatory response in gene expression that lasted until 42d post-exposure, raising concern over the chronic effects of CBNP exposure....... transcript levels were associated with immune-inflammatory response and acute phase response pathways, consistent with the BAL profiles and expression changes found in common respiratory infectious diseases. Genes involved in DNA repair, apoptosis, cell cycle regulation, and muscle contraction were also...... differentially expressed. Gene expression changes associated with inflammatory response followed a biphasic pattern, with initial changes at 3h post-exposure declining to base-levels by 3d, increasing again at 14d, and then persisting to 42d post-exposure. Thus, this single CBNP exposure that was equivalent...

  10. Ultrasound-guided single-penetration dual-injection block for leg and foot surgery

    DEFF Research Database (Denmark)

    Børglum, Jens; Johansen, Karina; Christensen, Karen Margrethe

    2014-01-01

    We describe a new approach to blocking the sciatic and saphenous nerves in the proximal thigh (level of the lesser trochanter or immediately below) using a single-penetration dual-injection (SPEDI) technique. The popliteal-sciatic approach necessitates repositioning of the leg exposing the poplit......We describe a new approach to blocking the sciatic and saphenous nerves in the proximal thigh (level of the lesser trochanter or immediately below) using a single-penetration dual-injection (SPEDI) technique. The popliteal-sciatic approach necessitates repositioning of the leg exposing...... the popliteal fossa and an extra injection for the saphenous nerve (SAN) block at the midthigh level. We introduce an alternative, effective, and possibly faster method....

  11. Ambiguity in measuring matrix diffusion with single-well injection/recovery tracer tests

    Science.gov (United States)

    Lessoff, S.C.; Konikow, Leonard F.

    1997-01-01

    Single-well injection/recovery tracer tests are considered for use in characterizing and quantifying matrix diffusion in dual-porosity aquifers. Numerical modeling indicates that neither regional drift in homogeneous aquifers, nor heterogeneity in aquifers having no regional drift, nor hydrodynamic dispersion significantly affects these tests. However, when drift is coupled simultaneously with heterogeneity, they can have significant confounding effects on tracer return. This synergistic effect of drift and heterogeneity may help explain irreversible flow and inconsistent results sometimes encountered in previous single-well injection/recovery tracer tests. Numerical results indicate that in a hypothetical single-well injection/recovery tracer test designed to demonstrate and measure dual-porosity characteristics in a fractured dolomite, the simultaneous effects of drift and heterogeneity sometimes yields responses similar to those anticipated in a homogeneous dual-porosity formation. In these cases, tracer recovery could provide a false indication of the occurrence of matrix diffusion. Shortening the shut-in period between injection and recovery periods may make the test less sensitive to drift. Using multiple tracers having different diffusion characteristics, multiple tests having different pumping schedules, and testing the formation at more than one location would decrease the ambiguity in the interpretation of test data.

  12. Comparison of the Pulmonary Oxidative Stress Caused by Intratracheal Instillation and Inhalation of NiO Nanoparticles when Equivalent Amounts of NiO Are Retained in the Lung

    Directory of Open Access Journals (Sweden)

    Masanori Horie

    2016-01-01

    Full Text Available NiO nanoparticles were administered to rat lungs via intratracheal instillation or inhalation. During pulmonary toxicity caused by NiO nanoparticles, the induction of oxidative stress is a major factor. Both intratracheal instillation and inhalation of NiO nanoparticles induced pulmonary oxidative stress. The oxidative stress response protein, heme oxygenase-1 (HO-1, was induced by the administration of NiO nanoparticles at both the protein and gene expression level. Additionally, certain oxidative-stress markers in the lung, such as 8-iso-prostaglandin F2α, thioredoxin, and inducible nitric oxide synthase were increased. Furthermore, the concentration of myeloperoxidase (MPO in the lung was also increased by the administration of NiO nanoparticles. When the amount of NiO in the lung is similar, the responses against pulmonary oxidative stress of intratracheal instillation and inhalation are also similar. However, the state of pulmonary oxidative stress in the early phase was different between intratracheal instillation and inhalation, even if the amount of NiO in the lung was similar. Inhalation causes milder oxidative stress than that caused by intratracheal instillation. On evaluation of the nanoparticle-induced pulmonary oxidative stress in the early phase, we should understand the different states of oxidative stress induced by intratracheal instillation and inhalation.

  13. [Creation of experimental emphysema by the intratracheal administration of papain].

    Science.gov (United States)

    Basmadzhieva, K; Kolev, K; Balabaeva, L

    1981-01-01

    The authors formed lung emphysema in white rats under experimental conditions by intratracheal application of various concentrations of papaine at different intervals. In the performed experiment the most suitable dose for formation of emphysema was two fold administration of 2 milligrams of papaine. The following indices were observed in the experimental and control animals: body weight, weight coefficient of the internal organs, indices of lipid and nucleinic metabolism in homogenates of lung as well as histomorphologic examination of lung.

  14. Long-term effects of intratracheally instilled 253EsCl3 in rats

    International Nuclear Information System (INIS)

    Ballou, J.E.; Dagle, G.E.; Morrow, W.

    1975-01-01

    ts administered 253 EsCl 3 by intratracheal instillation developed more bone tumors and fewer lung tumors than similar rats administered 239 Pu(NO 3 ) 4 . In explanation, it is suggested that 253 Es may irradiatete bone surface cells more effectively while 239 Pu may irradiate a greater total number of cells in the lung. (U.S.)

  15. Injection molded nanofluidic chips: Fabrication method and functional tests using single-molecule DNA experiments

    DEFF Research Database (Denmark)

    Utko, Pawel; Persson, Karl Fredrik; Kristensen, Anders

    2011-01-01

    We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels.......We demonstrate that fabrication of nanofluidic systems can be greatly simplified by injection molding of polymers. We functionally test our devices by single-molecule DNA experiments in nanochannels....

  16. Optimal sampling strategies to assess inulin clearance in children by the inulin single-injection method

    NARCIS (Netherlands)

    van Rossum, Lyonne K.; Mathot, Ron A. A.; Cransberg, Karlien; Vulto, Arnold G.

    2003-01-01

    Glomerular filtration rate in patients can be determined by estimating the plasma clearance of inulin with the single-injection method. In this method, a single bolus injection of inulin is administered and several blood samples are collected. For practical and convenient application of this method

  17. Ectopic Intratracheal Thyroid: A Rare Cause of Airway Obstruction

    Directory of Open Access Journals (Sweden)

    Waheed Rahman

    2018-01-01

    Full Text Available Ectopic intratracheal thyroid tissue (EITT is a rare abnormality with only limited cases reported so far. The presenting symptoms can be very similar to those of bronchial asthma. We discuss the case of a 29-year-old man with subglottic ectopic thyroid, with a history of thyroid surgery for goiter, which has been managed with laser-assisted endoscopic approach. We have also included presenting symptoms, pathophysiology, diagnosis, and management of EITT. We aim to include EITT in the differentials of airway obstruction, particularly in those patients who have goiter or previous thyroid surgeries.

  18. Efficient spin-current injection in single-molecule magnet junctions

    Directory of Open Access Journals (Sweden)

    Haiqing Xie

    2018-01-01

    Full Text Available We study theoretically spin transport through a single-molecule magnet (SMM in the sequential and cotunneling regimes, where the SMM is weakly coupled to one ferromagnetic and one normal-metallic leads. By a master-equation approach, it is found that the spin polarization injected from the ferromagnetic lead is amplified and highly polarized spin-current can be generated, due to the exchange coupling between the transport electron and the anisotropic spin of the SMM. Moreover, the spin-current polarization can be tuned by the gate or bias voltage, and thus an efficient spin injection device based on the SMM is proposed in molecular spintronics.

  19. Efficient spin-current injection in single-molecule magnet junctions

    Science.gov (United States)

    Xie, Haiqing; Xu, Fuming; Jiao, Hujun; Wang, Qiang; Liang, J.-Q.

    2018-01-01

    We study theoretically spin transport through a single-molecule magnet (SMM) in the sequential and cotunneling regimes, where the SMM is weakly coupled to one ferromagnetic and one normal-metallic leads. By a master-equation approach, it is found that the spin polarization injected from the ferromagnetic lead is amplified and highly polarized spin-current can be generated, due to the exchange coupling between the transport electron and the anisotropic spin of the SMM. Moreover, the spin-current polarization can be tuned by the gate or bias voltage, and thus an efficient spin injection device based on the SMM is proposed in molecular spintronics.

  20. Rapid dual-injection single-scan 13N-ammonia PET for quantification of rest and stress myocardial blood flows

    International Nuclear Information System (INIS)

    Rust, T C; DiBella, E V R; McGann, C J; Christian, P E; Hoffman, J M; Kadrmas, D J

    2006-01-01

    Quantification of myocardial blood flows at rest and stress using 13 N-ammonia PET is an established method; however, current techniques require a waiting period of about 1 h between scans. The objective of this study was to test a rapid dual-injection single-scan approach, where 13 N-ammonia injections are administered 10 min apart during rest and adenosine stress. Dynamic PET data were acquired in six human subjects using imaging protocols that provided separate single-injection scans as gold standards. Rest and stress data were combined to emulate rapid dual-injection data so that the underlying activity from each injection was known exactly. Regional blood flow estimates were computed from the dual-injection data using two methods: background subtraction and combined modelling. The rapid dual-injection approach provided blood flow estimates very similar to the conventional single-injection standards. Rest blood flow estimates were affected very little by the dual-injection approach, and stress estimates correlated strongly with separate single-injection values (r = 0.998, mean absolute difference = 0.06 ml min -1 g -1 ). An actual rapid dual-injection scan was successfully acquired in one subject and further demonstrates feasibility of the method. This study with a limited dataset demonstrates that blood flow quantification can be obtained in only 20 min by the rapid dual-injection approach with accuracy similar to that of conventional separate rest and stress scans. The rapid dual-injection approach merits further development and additional evaluation for potential clinical use

  1. Tunneling spin injection into single layer graphene.

    Science.gov (United States)

    Han, Wei; Pi, K; McCreary, K M; Li, Yan; Wong, Jared J I; Swartz, A G; Kawakami, R K

    2010-10-15

    We achieve tunneling spin injection from Co into single layer graphene (SLG) using TiO₂ seeded MgO barriers. A nonlocal magnetoresistance (ΔR(NL)) of 130  Ω is observed at room temperature, which is the largest value observed in any material. Investigating ΔR(NL) vs SLG conductivity from the transparent to the tunneling contact regimes demonstrates the contrasting behaviors predicted by the drift-diffusion theory of spin transport. Furthermore, tunnel barriers reduce the contact-induced spin relaxation and are therefore important for future investigations of spin relaxation in graphene.

  2. Protective Effects of Intratracheally-Administered Bee Venom Phospholipase A2 on Ovalbumin-Induced Allergic Asthma in Mice

    Directory of Open Access Journals (Sweden)

    Kyung-Hwa Jung

    2016-09-01

    Full Text Available Asthma is a common chronic disease characterized by bronchial inflammation, reversible airway obstruction, and airway hyperresponsiveness (AHR. Current therapeutic options for the management of asthma include inhaled corticosteroids and β2 agonists, which elicit harmful side effects. In the present study, we examined the capacity of phospholipase A2 (PLA2, one of the major components of bee venom (BV, to reduce airway inflammation and improve lung function in an experimental model of asthma. Allergic asthma was induced in female BALB/c mice by intraperitoneal administration of ovalbumin (OVA on days 0 and 14, followed by intratracheal challenge with 1% OVA six times between days 22 and 30. The infiltration of immune cells, such as Th2 cytokines in the lungs, and the lung histology, were assessed in the OVA-challenged mice in the presence and absence of an intratracheal administration of bvPLA2. We showed that the intratracheal administration of bvPLA2 markedly suppressed the OVA-induced allergic airway inflammation by reducing AHR, overall area of inflammation, and goblet cell hyperplasia. Furthermore, the suppression was associated with a significant decrease in the production of Th2 cytokines, such as IL-4, IL-5, and IL-13, and a reduction in the number of total cells, including eosinophils, macrophages, and neutrophils in the airway.

  3. Pathogenesis of infection with 2009 pandemic H1N1 influenza virus in isogenic guinea pigs after intranasal or intratracheal inoculation.

    Science.gov (United States)

    Wiersma, Lidewij C M; Vogelzang-van Trierum, Stella E; van Amerongen, Geert; van Run, Peter; Nieuwkoop, Nella J; Ladwig, Mechtild; Banneke, Stefanie; Schaefer, Hubert; Kuiken, Thijs; Fouchier, Ron A M; Osterhaus, Albert D M E; Rimmelzwaan, Guus F

    2015-03-01

    To elucidate the pathogenesis and transmission of influenza virus, the ferret model is typically used. To investigate protective immune responses, the use of inbred mouse strains has proven invaluable. Here, we describe a study with isogenic guinea pigs, which would uniquely combine the advantages of the mouse and ferret models for influenza virus infection. Strain 2 isogenic guinea pigs were inoculated with H1N1pdm09 influenza virus A/Netherlands/602/09 by the intranasal or intratracheal route. Viral replication kinetics were assessed by determining virus titers in nasal swabs and respiratory tissues, which were also used to assess histopathologic changes and the number of infected cells. In all guinea pigs, virus titers peaked in nasal secretions at day 2 after inoculation. Intranasal inoculation resulted in higher virus excretion via the nose and higher virus titers in the nasal turbinates than intratracheal inoculation. After intranasal inoculation, infectious virus was recovered only from nasal epithelium; after intratracheal inoculation, it was recovered also from trachea, lung, and cerebrum. Histopathologic changes corresponded with virus antigen distribution, being largely limited to nasal epithelium for intranasally infected guinea pigs and more widespread in the respiratory tract for intratracheally infected guinea pigs. In summary, isogenic guinea pigs show promise as a model to investigate the role of humoral and cell-mediated immunities to influenza and their effect on virus transmission. Copyright © 2015 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  4. Experimental investigations of a single cylinder genset engine with common rail fuel injection system

    Directory of Open Access Journals (Sweden)

    Gupta Paras

    2014-01-01

    Full Text Available Performance and emissions characteristics of compression ignition (CI engines are strongly dependent on quality of fuel injection. In an attempt to improve engine combustion, engine performance and reduce the exhaust emissions from a single cylinder constant speed genset engine, a common rail direct injection (CRDI fuel injection system was deployed and its injection timings were optimized. Results showed that 34°CA BTDC start of injection (SOI timings result in lowest brake specific fuel consumption (BSFC and smoke opacity. Advanced injection timings showed higher cylinder peak pressure, pressure rise rate, and heat release rate due to relatively longer ignition delay experienced.

  5. Effects of Stator Shroud Injection on the Aerodynamic Performance of a Single-Stage Transonic Axial Compressor

    Energy Technology Data Exchange (ETDEWEB)

    Dinh, Cong-Truong; Ma, Sang-Bum; Kim, Kwang Yong [Inha Univ., Incheon (Korea, Republic of)

    2017-01-15

    In this study, stator shroud injection in a single-stage transonic axial compressor is proposed. A parametric study of the effect of stator shroud injection on aerodynamic performances was conducted using the three-dimensional Reynolds-averaged Navier-Stokes equations. The curvature, length, width, and circumferential angle of the stator shroud injector and the air injection mass flow rate were selected as the test parameters. The results of the parametric study show that the aerodynamic performances of the single-stage transonic axial compressor were improved by stator shroud injection. The aerodynamic performances were the most sensitive to the injection mass flow rate. Further, the total pressure ratio and adiabatic efficiency were the maximum when the ratio of circumferential angle was 10%.

  6. Effects of Stator Shroud Injection on the Aerodynamic Performance of a Single-Stage Transonic Axial Compressor

    International Nuclear Information System (INIS)

    Dinh, Cong-Truong; Ma, Sang-Bum; Kim, Kwang Yong

    2017-01-01

    In this study, stator shroud injection in a single-stage transonic axial compressor is proposed. A parametric study of the effect of stator shroud injection on aerodynamic performances was conducted using the three-dimensional Reynolds-averaged Navier-Stokes equations. The curvature, length, width, and circumferential angle of the stator shroud injector and the air injection mass flow rate were selected as the test parameters. The results of the parametric study show that the aerodynamic performances of the single-stage transonic axial compressor were improved by stator shroud injection. The aerodynamic performances were the most sensitive to the injection mass flow rate. Further, the total pressure ratio and adiabatic efficiency were the maximum when the ratio of circumferential angle was 10%.

  7. Performance characterization of pneumatic single pellet injection system

    International Nuclear Information System (INIS)

    Schuresko, D.D.; Milora, S.L.; Hogan, J.T.; Foster, C.A.; Combs, S.K.

    1982-01-01

    The Oak Ridge National Laboratory single-shot pellet injector, which has been used in plasma fueling experiments on ISX and PDX, has been upgraded and extensively instrumented in order to study the gas dynamics of pneumatic pellet injection. An improved pellet transport line was developed which utilizes a 0.3-cm-diam by 100-cm-long guide tube. Pellet gun performance was characterized by measurements of breech and muzzle dynamic pressures and by pellet velocity and mass determinations. Velocities up to 1.4 km/s were achieved for intact hydrogen pellets using hydrogen propellant at 5-MPa breech pressure. These data have been compared with new pellet acceleration calculations which include the effects of propellant friction, heat transfer, time-dependent boundary conditions, and finite gun geometry. These results provide a basis for the extrapolation of present-day pneumatic injection system performance to velocities in excess of 2 km/s

  8. Performance characterization of pneumatic single pellet injection system

    International Nuclear Information System (INIS)

    Schuresko, D.D.; Milora, S.L.; Hogan, J.T.; Foster, C.A.; Combs, S.K.

    1983-01-01

    The Oak Ridge National Laboratory single-shot pellet injector, which has been used in plasma fueling experiments on ISX and PDX, has been upgraded and extensively instrumented in order to study the gas dyamics of pneumatic pellet injection. An improved pellet transport line was developed which utilizes a 0.3-cm-diam by 100-cm-long guide tube. Pellet gun performance was characterized by measurements of breech and muzzle dynamic pressures and by pellet velocity and mass determinations. Velocities of up to 1.4 km/s were achieved for intact hydrogen pellets using hydrogen propellant at 5-MPa breech pressure. These data have been compared with new pellet acceleration calculations which include the effects of propellant friction, heat transfer, time-dependent boundary conditions, and finite gun geometry. These results provide a basis for the extrapolation of present-day pneumatic injection system performance to velocities in excess of 2 km/s

  9. Intratracheal instillation of cerium oxide nanoparticles induces hepatic toxicity in male Sprague-Dawley rats

    Directory of Open Access Journals (Sweden)

    Nalabotu SK

    2011-10-01

    Full Text Available Siva K Nalabotu1,2, Madhukar B Kolli1,2, William E Triest3,4, Jane Y Ma5, Nandini DPK Manne2,6, Anjaiah Katta1,2, Hari S Addagarla2, Kevin M Rice2,6–8, Eric R Blough1,2,6,7,91Department of Pharmacology, Physiology and Toxicology, Marshall University, Joan C Edwards School of Medicine; 2Center for Diagnostic Nanosystems, Marshall University; 3Pathology and Laboratory Medicine Service, Veterans Affairs Medical Center; 4Section of Pathology, Department of Anatomy and Pathology, Joan C Edwards School of Medicine, Marshall University, Huntington; 5Health Effects Laboratory Division, NIOSH, Morgantown; 6Department of Biological Sciences; 7School of Kinesiology, College of Health Professions, Marshall University; 8Biotechnology Department, West Virginia State University; 9Department of Cardiology, Joan C Edwards School of Medicine, Marshall University Huntington, WV, USABackground: Cerium oxide (CeO2 nanoparticles have been posited to have both beneficial and toxic effects on biological systems. Herein, we examine if a single intratracheal instillation of CeO2 nanoparticles is associated with systemic toxicity in male Sprague-Dawley rats.Methods and results: Compared with control animals, CeO2 nanoparticle exposure was associated with increased liver ceria levels, elevations in serum alanine transaminase levels, reduced albumin levels, a diminished sodium-potassium ratio, and decreased serum triglyceride levels (P < 0.05. Consistent with these data, rats exposed to CeO2 nanoparticles also exhibited reductions in liver weight (P < 0.05 and dose-dependent hydropic degeneration, hepatocyte enlargement, sinusoidal dilatation, and accumulation of granular material. No histopathological alterations were observed in the kidney, spleen, and heart. Analysis of serum biomarkers suggested an elevation of acute phase reactants and markers of hepatocyte injury in the rats exposed to CeO2 nanoparticles.Conclusion: Taken together, these data suggest that

  10. Successful treatment of unicameral bone cyst by single percutaneous injection of alpha-BSM.

    Science.gov (United States)

    Thawrani, Dinesh; Thai, Chia Che; Welch, Robert D; Copley, Lawson; Johnston, Charles E

    2009-01-01

    Unicameral bone cyst (UBC) is a benign bone lesion, recognized for its high rate of recurrence and need for repeat procedures to achieve healing. We hypothesized that the osteoconductive material apatitic calcium phosphate (alpha-BSM) could be effective in filling and stimulating resolution of UBC. The purpose of this study was to evaluate clinical and radiographic outcomes of UBC treated by a single injection of alpha-BSM. Thirteen patients (6 male, 7 female) with a mean age of 10.5 years, underwent single percutaneous injection of alpha-BSM for presumed UBC. The aspiration of the cysts was followed by vigorous saline lavage using 2 wide bore needles to disrupt the cyst walls. alpha-BSM "paste" was then injected under fluoroscopic guidance. Radiographs were digitized to measure cystic area (millimeter squares) on 2 orthogonal views. Healing was rated according to a modified Neer outcome grading system. Nine of the 13 patients had had pathologic fractures in the past. Eleven of the 13 patients had had past unsuccessful treatment: multiple steroid injections in 6, curettage and bone grafting in 3, and bone marrow and demineralized bone matrix (Grafton) injection in 2. Five cysts were grade 1 (healed 100%), 6 grade 2 (healed >50%), 2 grade 3 (healed <50% with increased cortical thickness), and none grade 4 (recurrence/enlargement). The average resolution of cystic area in 11/13 cysts was 85.7% at final follow-up of 35.8 months (P=0.0001) with 2.8 mm of average gain in cortical thickness (P=0.0018). None of the 13 lesions required an additional procedure or repeat injection. All patients were clinically asymptomatic at latest follow-up. This is the first study quantifying cyst resolution objectively according to actual decrease in area (millimeter squares). A single injection of alpha-BSM is a safe, minimally invasive and efficacious method to treat UBC in the pediatric population.

  11. Single-use autoinjector for once-weekly intramuscular injection of IFNβ-1a.

    Science.gov (United States)

    Limmroth, Volker; Gerbershagen, Kathrin

    2014-12-01

    IFNβ products and glatiramer acetate are established treatment first-line options in long-term disease-modifying therapy of multiple sclerosis (MS). These self-injectable medications are used once weekly to once daily. Injection-related issues are common patient-cited reasons for nonadherence. Autoinjectors have been shown to support long-term adherence to injectable medications. The ability to self-inject in MS patients has been associated with a reduced risk of missed injections and drug discontinuation, and a beneficial effect on patient independence. The recently introduced easy-to-use prefilled once-weekly pen is a safe and effective device for intramuscular (IM) IFNβ-1a application and provides a convenient method for self-injection. We reviewed the available published evidence on the characteristics of this device. The once-weekly pen facilitates self-injection and was preferred over prefilled syringes by patients in a prospective open-label, multicenter Phase IIIb trial in MS patients who had been using IM IFNβ-1a in prefilled syringes. The simple and safe handling, shielded short needle, single-use disposable design and virtually painless injection by the device may contribute to adherence, quality of life and independence in patients using IM IFNβ-1a.

  12. Single intra-articular injection of high molecular weight hyaluronic acid for hip osteoarthritis.

    Science.gov (United States)

    Rivera, Fabrizio

    2016-03-01

    Intra-articular (IA) injection of hyaluronic acid (HA) into the hip joint appears to be safe and well tolerated but only a small number of randomized clinical trials in humans has been published. The objective of this prospective study was to evaluate the efficacy and safety of a single IA injection of high-molecular-weight (2800 kDa) HA (Coxarthrum) for hip osteoarthritis. All patients received a single IA administration of 2.5 % sodium hyaluronate (75 mg/3 mL) of high molecular weight. Fluoroscopy requires an iodized contrast medium (iopamidol, 1 ml) which highlights the capsule before administering HA. Patients were evaluated before IA injection (T0), after 3 months, after 6 months and after 1 year from injection. Results were evaluated by the Brief Pain Inventory (BPI II), Harris Hip Score and a visual analog scale of pain (pain VAS). All treated patients were considered for statistical analysis. Two hundred seven patients were included at T0. The mean age was 67 years (range 46-81). Regarding BPI severity score, changes in pain between T0 and the three following visits were statistically highly significant (p injection of Coxarthrum is effective from the third month and that the results are stable or continue to improve up to 1 year. IV.

  13. Acute and subchronic airway inflammation after intratracheal instillation of quartz and titanium dioxide agglomerates in mice

    DEFF Research Database (Denmark)

    Roursgaard, Martin; Jensen, Keld A; Poulsen, Steen Seier

    2011-01-01

    This study investigated the acute and subchronic inflammatory effects of micrometer-size (micro-size) and nanometer-size (nano-size) particles after intratracheal (i.t.) installation in mice. The role of the type of compound, polymorphism, and size of the particles was investigated. Studied compo...

  14. Synthesis and functionalization of dextran-based single-chain nanoparticles in aqueous media

    OpenAIRE

    Gracia R.; Marradi M.; Cossío U.; Benito A.; Pérez-San Vicente A.; Gómez-Vallejo V.; Grande H.-J.; Llop J.; and Loinaz I.

    2017-01-01

    Water-dispersible dextran-based single-chain polymer nanoparticles (SCPNs) were prepared in aqueous media and under mild conditions. Radiolabeling of the resulting biocompatible materials allowed the study of lung deposition of aqueous aerosols after intratracheal nebulization by means of single-photon emission computed tomography (SPECT), demonstrating their potential use as imaging contrast agents.

  15. Injection of a single electron from static to moving quantum dots.

    Science.gov (United States)

    Bertrand, Benoit; Hermelin, Sylvain; Mortemousque, Pierre-André; Takada, Shintaro; Yamamoto, Michihisa; Tarucha, Seigo; Ludwig, Arne; Wieck, Andreas D; Bäuerle, Christopher; Meunier, Tristan

    2016-05-27

    We study the injection mechanism of a single electron from a static quantum dot into a moving quantum dot. The moving quantum dots are created with surface acoustic waves (SAWs) in a long depleted channel. We demonstrate that the injection process is characterized by an activation law with a threshold that depends on the SAW amplitude and on the dot-channel potential gradient. By sufficiently increasing the SAW modulation amplitude, we can reach a regime where the transfer has unity probability and is potentially adiabatic. This study points to the relevant regime to use moving dots in quantum information protocols.

  16. Numerical simulations of single and multi-staged injection of H2 in a supersonic scramjet combustor

    Directory of Open Access Journals (Sweden)

    L. Abu-Farah

    2014-12-01

    Full Text Available Computational fluid dynamics (CFD simulations of a single staged injection of H2 through a central wedge shaped strut and a multi-staged injection through wall injectors are carried out by using Ansys CFX-12 code. Unstructured tetrahedral grids for narrow channel and quarter geometries of the combustor are generated by using ICEM CFD. Steady three-dimensional (3D Reynolds-averaged Navier-stokes (RANS simulations are carried out in the case of no H2 injection and compared with the simulations of single staged pilot and/or main H2 injections and multistage injection. Shear stress transport (SST based on k-ω turbulent model is adopted. Flow field visualization (complex shock waves interactions and static pressure distribution along the wall of the combustor are predicted and compared with the experimental schlieren images and measured wall static pressures for validation. A good agreement is found between the CFD predicted results and the measured data. The narrow and quarter geometries of the combustor give similar results with very small differences. Multi-staged injections of H2 enhance the turbulent H2/air mixing by forming vortices and additional shock waves (bow shocks.

  17. Carbon black nanoparticles induce biphasic gene expression changes associated with inflammatory responses in the lungs of C57BL/6 mice following a single intratracheal instillation

    International Nuclear Information System (INIS)

    Husain, Mainul; Kyjovska, Zdenka O.; Bourdon-Lacombe, Julie; Saber, Anne T.; Jensen, Keld A.; Jacobsen, Nicklas R.; Williams, Andrew; Wallin, Håkan; Halappanavar, Sabina; Vogel, Ulla; Yauk, Carole L.

    2015-01-01

    Inhalation of carbon black nanoparticles (CBNPs) causes pulmonary inflammation; however, time course data to evaluate the detailed evolution of lung inflammatory responses are lacking. Here we establish a time-series of lung inflammatory response to CBNPs. Female C57BL/6 mice were intratracheally instilled with 162 μg CBNPs alongside vehicle controls. Lung tissues were examined 3 h, and 1, 2, 3, 4, 5, 14, and 42 days (d) post-exposure. Global gene expression and pulmonary inflammation were assessed. DNA damage was evaluated in bronchoalveolar lavage (BAL) cells and lung tissue using the comet assay. Increased neutrophil influx was observed at all time-points. DNA strand breaks were increased in BAL cells 3 h post-exposure, and in lung tissues 2–5 d post-exposure. Approximately 2600 genes were differentially expressed (± 1.5 fold; p ≤ 0.05) across all time-points in the lungs of exposed mice. Altered transcript levels were associated with immune-inflammatory response and acute phase response pathways, consistent with the BAL profiles and expression changes found in common respiratory infectious diseases. Genes involved in DNA repair, apoptosis, cell cycle regulation, and muscle contraction were also differentially expressed. Gene expression changes associated with inflammatory response followed a biphasic pattern, with initial changes at 3 h post-exposure declining to base-levels by 3 d, increasing again at 14 d, and then persisting to 42 d post-exposure. Thus, this single CBNP exposure that was equivalent to nine 8-h working days at the current Danish occupational exposure limit induced biphasic inflammatory response in gene expression that lasted until 42 d post-exposure, raising concern over the chronic effects of CBNP exposure. - Highlights: • A single exposure to CBNPs induced expression changes in over 2600 genes in mouse lungs. • Altered genes were associated with immune-inflammatory and acute phase responses. • Several genes were involved in DNA

  18. Carbon black nanoparticles induce biphasic gene expression changes associated with inflammatory responses in the lungs of C57BL/6 mice following a single intratracheal instillation

    Energy Technology Data Exchange (ETDEWEB)

    Husain, Mainul, E-mail: mainul.husain@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Healthy Environments and Consumer Safety Branch, Health Canada, Ottawa, ON (Canada); Kyjovska, Zdenka O., E-mail: zky@nrcwe.dk [National Research Centre for the Working Environment, Copenhagen (Denmark); Bourdon-Lacombe, Julie, E-mail: julie.bourdon-lacombe@hc-sc.gc.ca [Water and Air Quality Bureau, Safe Environments Directorate, HECSB, Health Canada, Ottawa, ON (Canada); Saber, Anne T., E-mail: ats@nrcwe.dk [National Research Centre for the Working Environment, Copenhagen (Denmark); Jensen, Keld A., E-mail: kaj@arbejdsmiljoforskning.dk [National Research Centre for the Working Environment, Copenhagen (Denmark); Jacobsen, Nicklas R., E-mail: nrj@nrcwe.dk [National Research Centre for the Working Environment, Copenhagen (Denmark); Williams, Andrew, E-mail: andrew.williams@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Healthy Environments and Consumer Safety Branch, Health Canada, Ottawa, ON (Canada); Wallin, Håkan, E-mail: hwa@nrcwe.dk [National Research Centre for the Working Environment, Copenhagen (Denmark); Institute of Public Health, University of Copenhagen (Denmark); Halappanavar, Sabina, E-mail: sabina.halappanavar@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Healthy Environments and Consumer Safety Branch, Health Canada, Ottawa, ON (Canada); Vogel, Ulla, E-mail: ubv@nrcwe.dk [National Research Centre for the Working Environment, Copenhagen (Denmark); Institute of Micro- and Nanotechnology, Technical University of Denmark, Lyngby (Denmark); Yauk, Carole L., E-mail: carole.yauk@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Healthy Environments and Consumer Safety Branch, Health Canada, Ottawa, ON (Canada)

    2015-12-15

    Inhalation of carbon black nanoparticles (CBNPs) causes pulmonary inflammation; however, time course data to evaluate the detailed evolution of lung inflammatory responses are lacking. Here we establish a time-series of lung inflammatory response to CBNPs. Female C57BL/6 mice were intratracheally instilled with 162 μg CBNPs alongside vehicle controls. Lung tissues were examined 3 h, and 1, 2, 3, 4, 5, 14, and 42 days (d) post-exposure. Global gene expression and pulmonary inflammation were assessed. DNA damage was evaluated in bronchoalveolar lavage (BAL) cells and lung tissue using the comet assay. Increased neutrophil influx was observed at all time-points. DNA strand breaks were increased in BAL cells 3 h post-exposure, and in lung tissues 2–5 d post-exposure. Approximately 2600 genes were differentially expressed (± 1.5 fold; p ≤ 0.05) across all time-points in the lungs of exposed mice. Altered transcript levels were associated with immune-inflammatory response and acute phase response pathways, consistent with the BAL profiles and expression changes found in common respiratory infectious diseases. Genes involved in DNA repair, apoptosis, cell cycle regulation, and muscle contraction were also differentially expressed. Gene expression changes associated with inflammatory response followed a biphasic pattern, with initial changes at 3 h post-exposure declining to base-levels by 3 d, increasing again at 14 d, and then persisting to 42 d post-exposure. Thus, this single CBNP exposure that was equivalent to nine 8-h working days at the current Danish occupational exposure limit induced biphasic inflammatory response in gene expression that lasted until 42 d post-exposure, raising concern over the chronic effects of CBNP exposure. - Highlights: • A single exposure to CBNPs induced expression changes in over 2600 genes in mouse lungs. • Altered genes were associated with immune-inflammatory and acute phase responses. • Several genes were involved in DNA

  19. Safe and Effective Use of the Once Weekly Dulaglutide Single-Dose Pen in Injection-Naïve Patients With Type 2 Diabetes.

    Science.gov (United States)

    Matfin, Glenn; Van Brunt, Kate; Zimmermann, Alan G; Threlkeld, Rebecca; Ignaut, Debra A

    2015-04-21

    This 4-week, phase 3b, multicenter, open-label, single-arm, outpatient study demonstrated the safe and effective use of the dulaglutide single-dose pen containing 0.5 mL of placebo for subcutaneous injection in injection-naïve adult patients with type 2 diabetes (T2D), with A1C ≤ 8.5% (69 mmol/mol), BMI ≥ 23 kg/m2 and ≤ 45 kg/m(2). Patients completed a modified self-injecting subscale of the Diabetes Fear of Injecting and Self-Testing Questionnaire (mD-FISQ) and were trained to self-inject with the single-dose pen. Patients completed the initial self-injection at the site, injected at home for 2 subsequent weeks, and returned to the site for the final injection. The initial and final self-injections were evaluated for success; the final (initial) self-injection success rate was the primary (secondary) outcome measure, and the primary (secondary) objective was to demonstrate this success rate as being significantly greater than 80%. Patients recorded their level of pain after each injection. After the final injection, patients completed the mD-FISQ and the Medication Delivery Device Assessment Battery (MDDAB) to assess their perceptions of the single-dose pen, including ease of use and experience with the device. Among 211 patients (mean age: 61 years), the primary objective was met, with a final injection success rate of 99.1% (95% CI: 96.6% to 99.7%). Among 214 patients, the initial injection success rate was 97.2% (95% CI: 94.0% to 98.7%), meeting the key secondary objective. Overall, most patients (>96%) found the device easy to use, were satisfied with the device, and would be willing to continue to use the single-dose pen after the study. There was a significant reduction (P injecting, as measured by the mD-FISQ. The dulaglutide single-dose pen was found to be a safe and effective device for use by patients with T2D who were injection-naïve. A positive injection experience is an important factor for patients and providers when initiating injectable

  20. Transcatheter aortic-valve implantation with one single minimal contrast media injection.

    Science.gov (United States)

    Arrigo, Mattia; Maisano, Francesco; Haueis, Sabine; Binder, Ronald K; Taramasso, Maurizio; Nietlispach, Fabian

    2015-06-01

    Performing transcatheter aortic valve implantation (TAVI) with the use of minimal contrast in patients at high-risk for acute kidney injury (AKI). Contrast-induced nephropathy (CIN) is a major cause of AKI following TAVI and is associated with increased morbidity and mortality. The amount of contrast media used increases the risk for CIN. Computed tomography was omitted during the screening process. For the procedure transfemoral access was default. The self-expanding CoreValve prosthesis was chosen in all patients to minimize the risk of annular rupture in case of oversizing. Valve sizing was based on echocardiography, aortography, calcification on fluoroscopy, as well as weight and height of the patient. A single contrast injection was performed to confirm correct position of the pigtail catheter at the level of the annulus. The pigtail then served as the marker for the device landing zone. Intraprocedural assessment of the implantation result relied on echocardiography and hemodynamics. Five patients with severe aortic stenosis and at high risk for developing CIN were included. Device success was achieved in all patients and no major complications occurred. The median dose of injected contrast media was 8 ml (4-9). All but one patient had improved renal function after the intervention compared to baseline. Our study shows feasibility of performing TAVI with a single minimal contrast media injection, using a self-expandable valve. This technique has the potential to reduce the incidence of CIN. © 2015 Wiley Periodicals, Inc.

  1. Intervention effect and dose-dependent response of tanreqing injection on airway inflammation in lipopolysaccharide-induced rats.

    Science.gov (United States)

    Dong, Shoujin; Zhong, Yunqing; Yang, Kun; Xiong, Xiaoling; Mao, Bing

    2013-08-01

    To assess the effect of Tanreqing injection on airway inflammation in rats. A rat model of airway inflammation was generated with lipopolysaccharide (LPS). Tanreqing injection was given by intratracheal instillation, and bronchoalveolar lavage fluid (BALF) from the right lung was collected. BALF total cell and neutrophil counts were then determined. In addition, BALF levels of inflammatory cytokines interleukin-13, cytokine-induced neutrophil chemoat-tractant-1, and tumor necrosis factor-alpha were measured using enzyme linked immunosorbent assay. The middle lobe of the right lung was stained with hematoxylin-eosin and histological changes examined. LPS increased airway inflammation, decreased BALF inflammatory cell count, inflammatory cytokine levels, and suppressed leukocyte influx of the lung. The LPS-induced airway inflammation peaked at 24 h, decreased beginning at 48 h, and had decreased markedly by 96 h. Tanreqing injection contains anti-inflammatory properties, and inhibits airway inflammation in a dose-dependent manner.

  2. Intranasal H5N1 vaccines, adjuvanted with chitosan derivatives, protect ferrets against highly pathogenic influenza intranasal and intratracheal challenge.

    Directory of Open Access Journals (Sweden)

    Alex J Mann

    Full Text Available We investigated the protective efficacy of two intranasal chitosan (CSN and TM-CSN adjuvanted H5N1 Influenza vaccines against highly pathogenic avian Influenza (HPAI intratracheal and intranasal challenge in a ferret model. Six groups of 6 ferrets were intranasally vaccinated twice, 21 days apart, with either placebo, antigen alone, CSN adjuvanted antigen, or TM-CSN adjuvanted antigen. Homologous and intra-subtypic antibody cross-reacting responses were assessed. Ferrets were inoculated intratracheally (all treatments or intranasally (CSN adjuvanted and placebo treatments only with clade 1 HPAI A/Vietnam/1194/2004 (H5N1 virus 28 days after the second vaccination and subsequently monitored for morbidity and mortality outcomes. Clinical signs were assessed and nasal as well as throat swabs were taken daily for virology. Samples of lung tissue, nasal turbinates, brain, and olfactory bulb were analysed for the presence of virus and examined for histolopathological findings. In contrast to animals vaccinated with antigen alone, the CSN and TM-CSN adjuvanted vaccines induced high levels of antibodies, protected ferrets from death, reduced viral replication and abrogated disease after intratracheal challenge, and in the case of CSN after intranasal challenge. In particular, the TM-CSN adjuvanted vaccine was highly effective at eliciting protective immunity from intratracheal challenge; serologically, protective titres were demonstrable after one vaccination. The 2-dose schedule with TM-CSN vaccine also induced cross-reactive antibodies to clade 2.1 and 2.2 H5N1 viruses. Furthermore ferrets immunised with TM-CSN had no detectable virus in the respiratory tract or brain, whereas there were signs of virus in the throat and lungs, albeit at significantly reduced levels, in CSN vaccinated animals. This study demonstrated for the first time that CSN and in particular TM-CSN adjuvanted intranasal vaccines have the potential to protect against significant

  3. The efficacy of multiple versus single hyaluronic acid injections: a systematic review and meta-analysis.

    Science.gov (United States)

    Concoff, Andrew; Sancheti, Parag; Niazi, Faizan; Shaw, Peter; Rosen, Jeffrey

    2017-12-21

    Intra-articular hyaluronic acid (IA-HA) is a common therapy used to treat knee pain and suppress knee inflammation in knee osteoarthritis (OA), typically prescribed in regimens ranging from a single injection to 5 weekly injections given once weekly. We conducted a systematic review to determine the efficacy of IA-HA, with subgroup analyses to explore the differences in knee pain and adverse events (AEs) across different dosing regimens. We conducted a systematic search of the literature to identify studies evaluating IA-HA for the management of knee OA compared to IA-saline. Primary outcome measure was the mean knee pain score at 13 Weeks (3 months) or 26 weeks (6 months). Secondary outcome was the number of treatment-related AEs and treatment-related serious adverse events (SAEs). We evaluated differences in levels of pain and AEs/SAEs between dosing regimens compared to IA-Saline. Thirty articles were included. Overall, IA-HA injections were associated with less knee pain compared to IA-Saline injections for all dosing regimens. 2-4 injections of IA-HA vs. IA-Saline produced the largest effect size at both 3-months and 6-months (Standard mean difference [SMD] = -0.76; -0.98 to -0.53, 95% CI, P injection studies yielded a non-significant treatment effect at 3 and 6 months, while ≥5 5 injections demonstrated a significant improvement in pain only at 6 months. Five or more injections of IA-HA were associated with a higher risk of treatment-related AEs compared to IA-Saline (Risk ratio [RR] = 1.67; 1.09 to 2.56 95% CI, p = 0.02), which was a result not seen within the 1 and 2-4 injection subgroups. Overall, 2-4 and ≥5 injection regimens provided pain relief over IA-Saline, while single injection did not. Intra-articular injections of HA used in a 2-4 injection treatment regimen provided the greatest benefit when compared to IA-Saline with respect to pain improvement in patients with knee OA, and was generally deemed safe with few to no

  4. 3D-CFD Simulation of Confined Cross-Flow Injection Process Using Single Piston Pump

    Directory of Open Access Journals (Sweden)

    M. Elashmawy

    2017-12-01

    Full Text Available Injection process into a confined cross flow is quite important for many applications including chemical engineering and water desalination technology. The aim of this study is to investigate the performance of the injection process into a confined cross-flow of a round pipe using a single piston injection pump. A computational fluid dynamics (CFD analysis has been carried out to investigate the effect of the locations of the maximum velocity and minimum pressure on the confined cross-flow process. The jet trajectory is analyzed and related to the injection pump shaft angle of rotation during the injection duty cycle by focusing on the maximum instant injection flow of the piston action. Results indicate a low effect of the jet trajectory within the range related to the injection pump operational conditions. Constant cross-flow was used and injection flow is altered to vary the jet to line flow ratio (QR. The maximum jet trajectory exhibits low penetration inside the cross-flow. The results showed three regions of the flow ratio effect zones with different behaviors. Results also showed that getting closer to the injection port causes a significant decrease on the locations of the maximum velocity and minimum pressure.

  5. Acute and subacute pulmonary toxicity caused by a single intratracheal instillation of colloidal silver nanoparticles in mice: pathobiological changes and metallothionein responses.

    Science.gov (United States)

    Kaewamatawong, Theerayuth; Banlunara, Wijit; Maneewattanapinyo, Pattwat; Thammachareon, Chuchaat; Ekgasit, Sanong

    2014-01-01

    To study the acute and subacute pulmonary toxicity of colloidal silver nanoparticles (Ag-NPs), 0 or 100 ppm of Ag-NPs were instilled intratracheally in mice. Cellular and biochemical parameters in bronchoalveolar lavage fluid (BALF) and histological alterations were determined 1, 3, 7, 15, and 30 days after instillation. Ag-NPs induced moderate pulmonary inflammation and injury on BALF indices during the acute period; however, these changes gradually regressed in a time-dependent manner. Concomitant histopathological and laminin immunohistochemical findings generally correlated to BALF data. Superoxide dismutase and metallothionein expression occurred in particle-laden macrophages and alveolar epithelial cells, which correlated to lung lesions in mice treated with Ag-NPs. These findings suggest that instillation of Ag-NPs causes transient moderate acute lung inflammation and tissue damage. Oxidative stress may underlie the induction of injury to lung tissue. Moreover, the expression of metallothionein in tissues indicated the protective response to exposure to Ag-NPs.

  6. [Comparison of basic carboxypeptidases activity in male rats tissues at a single injection of haloperidol].

    Science.gov (United States)

    Pravosudova, N A; Bykova, I O

    2014-01-01

    The influence of a single injection of haloperidol on basic carboxypeptidases (biologically active peptide processing enzymes) activity in rat tissues was studied. Acute exposure to haloperidol increased the activity of carboxypeptidases H (CP H) in hypothalamic-pituitary-adrenal system and cerebellum and reduced such activity in testes. Multidirectional changes of PMSF-inhibited carboxypeptidases activity (PMSF-CP) were observed after a single haloperidol injection in all studied tissues except testes. It is suggested that changes of CP H and PMSF-CP activity might affect levels of regulatory peptides in the brain and blood and thus may be involved in general and side effects of haloperidol on the organism.

  7. A newly developed tool for intra-tracheal temperature and humidity assessment in laryngectomized individuals: the Airway Climate Explorer (ACE)

    NARCIS (Netherlands)

    Zuur, J.K.; Muller, S.H.; Jongh, F.H.C.; Horst, M.J. van der; Shehata, M.; Leeuwen, J. van; Sinaasappel, M.; Hilgers, F.J.M.

    2007-01-01

    The aim of this study is to develop a postlaryngectomy airway climate explorer (ACE) for assessment of intratracheal temperature and humidity and of influence of heat and moisture exchangers (HMEs). Engineering goals were within-device condensation prevention and fast response time characteristics.

  8. Opto-injection into single living cells by femtosecond near-infrared laser

    Science.gov (United States)

    Peng, Cheng

    This dissertation presents a novel technique to deliver membrane impermeable molecules into single living cells with the assistance of femtosecond (fs) near-infrared (NIR) laser pulses. This approach merges ultrafast laser technology with key biological, biomedical, and medical applications, such as gene transfection, gene therapy and drug delivery. This technique promises several major advantages, namely, very high transfection efficiency, high cell survival rate (≈100%) and fully preserved cell viabilities. It is also a promising method to deliver molecules into cells that are difficult or even completely resistant to established physical methods, such as microinjection by glass pipettes, electroporation, and biolistics. In this work, the system for fs NIR opto-injection was designed and built. Successful fs NIR opto-injection has been performed on several cell systems including single mammalian cells (bovine aortic endothelial cells), marine animal eggs (Spisula solidissima oocytes), and human cancer cells (fibrosarcoma HT1080) cultured in a tissue-like environment. The connections between laser parameters and cell responses were explored through further experiments and in-depth analyses, especially the relationship between dye uptake rate and incident laser intensity, and the relationship between pore size created on cell membranes and incident laser intensity. Dye uptake rate of the target cells was observed to depend on incident laser intensity. Pore size was found dependent on incident laser intensity. The conclusion was made that laser-induced breakdown and plasma-induced ablation in cell membrane are the physical principles that govern the process of fs NIR opto-injection.

  9. Efficacy Of A Single-Injection Sodium Hyaluronate Treatment In Lateral Epicondylitis.

    Science.gov (United States)

    Khan, Inam Ullah; Awan, Abdus Saboor; Khan, Aimal Sattar; Marwat, Imran; Meraj, Muhammad

    2018-01-01

    Lateral epicondylitis or tennis elbow is a disease of tendons arising from common extensor origin at the lateral epicondyle of elbow and is commonly characterized by pain on supination of forearms as well as extension of fingers and wrists. This descriptive case series aims to determine the efficacy of a single-injection sodium hyaluronate treatment for lateral epicondylitis. The study was conducted at the Department of Orthopaedics. Ayub Teaching Hospital Abbottabad. From February 1 to August 31, 2014. Patients diagnosed with lateral epicondylitis were administered 1 cc of 1% Sodium hyaluronate 1 cm from the lateral epicondyle into the soft tissue. Hyaluronic acid is more effective in patients with moderate pain of lateral epicondylitis (VAS score ≤7 than in patients with severe pain (VAS score >7). Paired sample t-test was used to compared the means of the pre- and post-procedure VAS score and the difference was found to be statistically very significant (p=0.00) with a mean±SD change in VAS of 2.31±1.35 at 4 weeks. A single injection of sodium hyaluronate is effective in management of moderate, but not severe pain of lateral epicondylitis.

  10. Single step production of Cas9 mRNA for zygote injection.

    Science.gov (United States)

    Redel, Bethany K; Beaton, Benjamin P; Spate, Lee D; Benne, Joshua A; Murphy, Stephanie L; O'Gorman, Chad W; Spate, Anna M; Prather, Randall S; Wells, Kevin D

    2018-03-01

    Production of Cas9 mRNA in vitro typically requires the addition of a 5´ cap and 3´ polyadenylation. A plasmid was constructed that harbored the T7 promoter followed by the EMCV IRES and a Cas9 coding region. We hypothesized that the use of the metastasis associated lung adenocarcinoma transcript 1 (Malat1) triplex structure downstream of an IRES/Cas9 expression cassette would make polyadenylation of in vitro produced mRNA unnecessary. A sequence from the mMalat1 gene was cloned downstream of the IRES/Cas9 cassette described above. An mRNA concentration curve was constructed with either commercially available Cas9 mRNA or the IRES/ Cas9/triplex, by injection into porcine zygotes. Blastocysts were genotyped to determine if differences existed in the percent of embryos modified. The concentration curve identified differences due to concentration and RNA type injected. Single step production of Cas9 mRNA provides an alternative source of Cas9 for use in zygote injections.

  11. Symptomatic Spinal Epidural Lipomatosis After a Single Local Epidural Steroid Injection

    International Nuclear Information System (INIS)

    Tok, Chung Hong; Kaur, Shaleen; Gangi, Afshin

    2011-01-01

    Spinal epidural lipomatosis is a rare disorder that can manifest with progressive neurological deficits. It is characterized by abnormal accumulation of unencapsulated epidural fat commonly associated with the administration of exogenous steroids associated with a variety of systemic diseases, endocrinopathies, and Cushing syndrome (Fogel et al. Spine J 5:202–211, 2005). Occasionally, spinal epidural lipomatosis may occur in patients not exposed to steroids or in patients with endocrinopathies, primarily in obese individuals (Fogel et al. Spine J 5:202–211, 2005). However, spinal lumbar epidural lipomatosis resulting from local steroid injection has rarely been reported. We report the case of a 45-year-old diabetic man with claudication that was probably due to symptomatic lumbar spinal lipomatosis resulting from a single local epidural steroid injection.

  12. The data analysis of the single well injection-withdraw tracer experiment using the MACRO II

    International Nuclear Information System (INIS)

    Shirakawa, Toshihiko; Kanazawa, Yasuo; Hatanaka, Koichiro

    2001-04-01

    On understanding the radionuclide transport in natural barrier in radioactive waste isolation research, the macroscopic dispersion in heterogeneous permeability field in the underground rock is regarded as an important process. Therefore, we have conducted lots of tracer experiments by the MACRO II facility with an artificially constructed heterogeneous permeability field. In order to study the scale dependence of dispersion coefficients in case of laboratory experiments, we placed the flow cell horizontally, and conducted injection-withdraw tracer experiment with a single well. We have conducted 15 cases experiments. These cases were prepared by changing a position of single well and the injection-withdraw time. At each position we have conducted 9 cases and 6 cases experiments. In this report, we evaluated the macroscopic dispersion coefficients by the fitting of analytical solution to breakthrough curve measured by the 15 cases pumping tracer experiment. Consequently, we could evaluate the dispersion coefficients for 12 cases of 15 cases. Then, we discussed the relation between a injection-withdraw flow rate and a property of heterogeneous media and dispersion coefficient. The conclusions obtained from the results of the evaluation are summarized as follows, It was found that the macroscopic dispersion coefficients tend to be increased with increase of the average radius of tracer front spread around a single well. We have conducted any experiments with s single well settled at two positions. In case of that there is low permeability around a single well, we found dispersion coefficients are large. In case of that there is high permeability around a single well, we found dispersion coefficients are small. In three cases that we could not evaluate because of incorrect accuracy of fitting, we have found it possible that there is some points that dispersion coefficients were strikingly small in tracer front. (author)

  13. Localization and (semi-)quantification of fluorescent beads of 2 sizes in chickens over time after simultaneous intratracheal and cloacal administration

    NARCIS (Netherlands)

    Berghof, T.V.L.; Lai, T.L.H.; Lammers, A.; Vries Reilingh, de G.; Nieuwland, M.G.B.; Aarnink, A.J.A.; Parmentier, H.K.

    2013-01-01

    Environmental particles enter the chicken via several routes. Entry via the respiratory and cloacal routes likely activates immune responses. We studied the localization of simultaneous intratracheally and cloacally applied beads of 2 sizes in the chicken body in time, and when possible,

  14. Transfer of single dose of intravitreal injection of ranibizumab and bevacizumab into milk of sheep

    Directory of Open Access Journals (Sweden)

    Tugba Cakmak Argun

    2017-07-01

    Full Text Available AIM: To investigate whether single-dose intravitreal injections of bevacizumab and ranibizumab transfer into milk. METHODS: This study included lactating 12 sheep and a single 3-month old suckling lamb of each sheep. Two groups consisting of 6 sheep and their lambs were constituted; the ranibizumab group and the bevacizumab group before the administration of intravitreal injections, blood and milk samples were obtained from all sheep and, following the injections, blood and milk samples of all sheep and blood samples of all lambs were collected at regular time points. Serum and milk concentrations of bevacizumab and ranibizumab were measured using an enzyme-linked immunosorbent assay (ELISA kit. The limit of determination was 0.9 ng/mL for bevacizumab and 0.62 ng/mL for ranibizumab. RESULTS: At 6h after intravitreal injections, bevacizumab concentration was above the limit of determination in the blood of all sheep. At 3wk, when the study was terminated, bevacizumab concentrations were high in 4 sheep. Even though bevacizumab concentrations in milk showed fluctuations, the drug transferred into the milk of all sheep at detectable concentrations. Ranibizumab drug concentrations in the blood and milk of sheep and those in the blood of lambs were below the limit of determination by the ELISA kit. CONCLUSION: This sheep model study demonstrate that intravitreal injection of ranibizumab, which did not transfer into the milk of sheep and suckling lambs, is safer than bevacizumab during lactation period.

  15. Single injection of basic fibroblast growth factor to treat severe vocal fold lesions and vocal fold paralysis.

    Science.gov (United States)

    Kanazawa, Takeharu; Komazawa, Daigo; Indo, Kanako; Akagi, Yusuke; Lee, Yogaku; Nakamura, Kazuhiro; Matsushima, Koji; Kunieda, Chikako; Misawa, Kiyoshi; Nishino, Hiroshi; Watanabe, Yusuke

    2015-10-01

    Severe vocal fold lesions such as vocal fold sulcus, scars, and atrophy induce a communication disorder due to severe hoarseness, but a treatment has not been established. Basic fibroblast growth factor (bFGF) therapies by either four-time repeated local injections or regenerative surgery for vocal fold scar and sulcus have previously been reported, and favorable outcomes have been observed. In this study, we modified bFGF therapy using a single of bFGF injection, which may potentially be used in office procedures. Retrospective chart review. Five cases of vocal fold sulcus, six cases of scars, seven cases of paralysis, and 17 cases of atrophy were treated by a local injection of bFGF. The injection regimen involved injecting 50 µg of bFGF dissolved in 0.5 mL saline only once into the superficial lamina propria using a 23-gauge injection needle. Two months to 3 months after the injection, phonological outcomes were evaluated. The maximum phonation time (MPT), mean airflow rate, pitch range, speech fundamental frequency, jitter, and voice handicap index improved significantly after the bFGF injection. Furthermore, improvement in the MPT was significantly greater in patients with (in increasing order) vocal fold atrophy, scar, and paralysis. The improvement in the MPT among all patients was significantly correlated with age; the MPT improved more greatly in younger patients. Regenerative treatments by bFGF injection—even a single injection—effectively improve vocal function in vocal fold lesions. 4 © 2015 The American Laryngological, Rhinological and Otological Society, Inc.

  16. Single, double or multiple-injection techniques for non-ultrasound guided axillary brachial plexus block in adults undergoing surgery of the lower arm.

    Science.gov (United States)

    Chin, Ki Jinn; Alakkad, Husni; Cubillos, Javier E

    2013-08-08

    Regional anaesthesia comprising axillary block of the brachial plexus is a common anaesthetic technique for distal upper limb surgery. This is an update of a review first published in 2006 and updated in 2011. To compare the relative effects (benefits and harms) of three injection techniques (single, double and multiple) of axillary block of the brachial plexus for distal upper extremity surgery. We considered these effects primarily in terms of anaesthetic effectiveness; the complication rate (neurological and vascular); and pain and discomfort caused by performance of the block. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library), MEDLINE, EMBASE and reference lists of trials. We contacted trial authors. The date of the last search was March 2013 (updated from March 2011). We included randomized controlled trials that compared double with single-injection techniques, multiple with single-injection techniques, or multiple with double-injection techniques for axillary block in adults undergoing surgery of the distal upper limb. We excluded trials using ultrasound-guided techniques. Independent study selection, risk of bias assessment and data extraction were performed by at least two investigators. We undertook meta-analysis. The 21 included trials involved a total of 2148 participants who received regional anaesthesia for hand, wrist, forearm or elbow surgery. Risk of bias assessment indicated that trial design and conduct were generally adequate; the most common areas of weakness were in blinding and allocation concealment.Eight trials comparing double versus single injections showed a statistically significant decrease in primary anaesthesia failure (risk ratio (RR 0.51), 95% confidence interval (CI) 0.30 to 0.85). Subgroup analysis by method of nerve location showed that the effect size was greater when neurostimulation was used rather than the transarterial technique.Eight trials comparing multiple with single

  17. Impact of charge carrier injection on single-chain photophysics of conjugated polymers

    Energy Technology Data Exchange (ETDEWEB)

    Hofmann, Felix J.; Vogelsang, Jan, E-mail: jan.vogelsang@physik.uni-regensburg.de; Lupton, John M. [Institut für Experimentelle und Angewandte Physik, Universität Regensburg, Universitätsstrasse 31, 93053 Regensburg (Germany)

    2016-06-27

    Charges in conjugated polymer materials have a strong impact on the photophysics and their interaction with the primary excited state species has to be taken into account in understanding device properties. Here, we employ single-molecule spectroscopy to unravel the influence of charges on several photoluminescence (PL) observables. The charges are injected either stochastically by a photochemical process or deterministically in a hole-injection sandwich device configuration. We find that upon charge injection, besides a blue-shift of the PL emission and a shortening of the PL lifetime due to quenching and blocking of the lowest-energy chromophores, the non-classical photon arrival time distribution of the multichromophoric chain is modified towards a more classical distribution. Surprisingly, the fidelity of photon antibunching deteriorates upon charging, whereas one would actually expect the opposite: the number of chromophores to be reduced. A qualitative model is presented to explain the observed PL changes. The results are of interest to developing a microscopic understanding of the intrinsic charge-exciton quenching interaction in devices.

  18. Intentional intra-arterial injection of midazolam in a patient with status epilepticus in the intensive care unit

    Directory of Open Access Journals (Sweden)

    Muhammad Asghar Ali

    2017-01-01

    Full Text Available Fundamental medical care includes intravenous (IV access which provides prompt resuscitation and reliable delivery of analgesics, antibiotics, and vasoactive medication. Difficult access populations, especially in critical area, continue to challenge providers to consider and utilize alternative means to provide IV access. Potential options under such circumstances include intramuscular, intraosseous, and intratracheal drug administration, but in extreme cases where no other options are available, intra-arterial route might be considered. We present a case where midazolam was intentionally injected intra-arterially to abort seizure activity in a patient with status epilepticus in the Intensive Care Unit.

  19. Single intravitreal bevacizumab injection effects on contrast sensitivity in macular edema from branch retinal vein occlusion

    Directory of Open Access Journals (Sweden)

    Rony Carlos Preti

    2012-02-01

    Full Text Available PURPOSE: To evaluate the effect of a single intravitreal bevacizumab injection on visual acuity, contrast sensitivity and optical coherence tomography-measured central macular thickness in eyes with macular edema from branch retinal vein occlusion. METHODS: Seventeen eyes of 17 patients with macular edema from unilateral branch retinal vein occlusion were treated with a single bevacizumab injection. Patients were submitted to a complete evaluation including best corrected visual acuity, contrast sensitivity and optical coherence tomography measurements before treatment and one and three months after injection. Visual acuity, contrast sensitivity and optical coherence tomography measurements were compared to baseline values. RESULTS: Mean visual acuity measurement improved from 0.77 logMAR at baseline to 0.613 logMAR one month after injection (P=0.0001 but worsened to 0.75 logMAR after three months. Contrast sensitivity test demonstrated significant improvement at spatial frequencies of 3, 6, 12 and 18 cycles/degree one month after injection and at the spatial frequency of 12 cycles/degree three months after treatment. Mean ± standard deviation baseline central macular thickness (552 ± 150 µm reduced significantly one month (322 ± 127 µm, P=0.0001 and three months (439 ± 179 µm, P=0.01 after treatment. CONCLUSIONS: Bevacizumab injection improves visual acuity and contrast sensitivity and reduces central macular thickness one month after treatment. Visual acuity returns to baseline levels at the 3-month follow-up, but some beneficial effect of the treatment is still present at that time, as evidenced by optical coherence tomography-measured central macular thickness and contrast sensitivity measurements.

  20. Intratracheal Administration of Small Interfering RNA Targeting Fas Reduces Lung Ischemia-Reperfusion Injury.

    Science.gov (United States)

    Del Sorbo, Lorenzo; Costamagna, Andrea; Muraca, Giuseppe; Rotondo, Giuseppe; Civiletti, Federica; Vizio, Barbara; Bosco, Ornella; Martin Conte, Erica L; Frati, Giacomo; Delsedime, Luisa; Lupia, Enrico; Fanelli, Vito; Ranieri, V Marco

    2016-08-01

    Lung ischemia-reperfusion injury is the main cause of primary graft dysfunction after lung transplantation and results in increased morbidity and mortality. Fas-mediated apoptosis is one of the pathologic mechanisms involved in the development of ischemia-reperfusion injury. We hypothesized that the inhibition of Fas gene expression in lungs by intratracheal administration of small interfering RNA could reduce lung ischemia-reperfusion injury in an ex vivo model reproducing the procedural sequence of lung transplantation. Prospective, randomized, controlled experimental study. University research laboratory. C57/BL6 mice weighing 28-30 g. Ischemia-reperfusion injury was induced in lungs isolated from mice, 48 hours after treatment with intratracheal small interfering RNA targeting Fas, control small interfering RNA, or vehicle. Isolated lungs were exposed to 6 hours of cold ischemia (4°C), followed by 2 hours of warm (37°C) reperfusion with a solution containing 10% of fresh whole blood and mechanical ventilation with constant low driving pressure. Fas gene expression was significantly silenced at the level of messenger RNA and protein after ischemia-reperfusion in lungs treated with small interfering RNA targeting Fas compared with lungs treated with control small interfering RNA or vehicle. Silencing of Fas gene expression resulted in reduced edema formation (bronchoalveolar lavage protein concentration and lung histology) and improvement in lung compliance. These effects were associated with a significant reduction of pulmonary cell apoptosis of lungs treated with small interfering RNA targeting Fas, which did not affect cytokine release and neutrophil infiltration. Fas expression silencing in the lung by small interfering RNA is effective against ischemia-reperfusion injury. This approach represents a potential innovative strategy of organ preservation before lung transplantation.

  1. Intraperitoneal Injection Is Not a Suitable Administration Route for Single-Walled Carbon Nanotubes in Biomedical Applications

    OpenAIRE

    Liu, Xudong; Guo, Qing; Zhang, Yuchao; Li, Jinquan; Li, Rui; Wu, Yang; Ma, Ping; Yang, Xu

    2016-01-01

    Given the extensive application of carbon nanotubes (CNTs) in biomedical fields, there is increasing concern regarding unintentional health impacts. Research into safe usage is therefore increasingly necessary. This study investigated the responses of the mouse brain to single-walled CNTs (SWCNTs) delivered via intraperitoneal (IP) injection and compared these results with the previous study where SWCNTs were delivered via intravenous (IV) injection so as to explore which administration route...

  2. Biodistribution of gold nanoparticles following intratracheal instillation in mouse lung

    DEFF Research Database (Denmark)

    Sadauskas, Evaldas; Jacobsen, Nicklas R.; Danscher, Gorm

    2009-01-01

    plasma mass spectrometry (ICP-MS) and neutron activation analysis (NAA). The liver is the major site of deposition of circulating gold nanoparticles. Therefore the degree of translocation was determined by the hepatic deposition of gold. Mice were instilled with 5 intratracheal doses of gold...... repeatedly during 3 weeks, the load was substantial. Ultrastructurally, AMG silver enhanced gold nanoparticles were found in lysosome-/endosome-like organelles of the macrophages and analysis with AMG, ICP-MS and NAA of the liver revealed an almost total lack of translocation of nanoparticles. In mice given...... repeated instillations of 2 nm gold nanoparticles, 1.4‰ (by ICP-MS) to 1.9‰ (by NAA) of the instilled gold was detected in the liver. With the 40 nm gold, no gold was detected in the liver (detection level 2 ng, 0.1‰) except for one mouse in which 3‰ of the instilled gold was found in the liver. No gold...

  3. Single-mode Brillouin fiber laser passively stabilized at resonance frequency with self-injection locked pump laser

    International Nuclear Information System (INIS)

    Spirin, V V; Lopez-Mercado, C A; Megret, P; Fotiadi, A A

    2012-01-01

    We demonstrate a single-mode Brillouin fiber ring laser, which is passively stabilized at pump resonance frequency by using self-injection locking of semiconductor pump laser. Resonance condition for Stokes radiation is achieved by length fitting of Brillouin laser cavity. The laser generate single-frequency Stokes wave with linewidth less than 0.5 kHz using approximately 17-m length cavity

  4. Optimizing CT angiography in patients with Fontan physiology: single-center experience of dual-site power injection

    International Nuclear Information System (INIS)

    Sandler, K.L.; Markham, L.W.; Mah, M.L.; Byrum, E.P.; Williams, J.R.

    2014-01-01

    Aim: To identify adult patients with single-ventricle congenital heart disease and Fontan procedure palliation who have been misdiagnosed with or incompletely evaluated for pulmonary embolism. Additionally, this study was designed to demonstrate that simultaneous, dual-injection of contrast medium into an upper and lower extremity vein is superior to single-injection protocols for CT angiography (CTA) of the chest in this population. Materials and methods: Patients included in the study were retrospectively selected from the Adult Congenital Heart Disease (ACHD) database. Search criteria included history of Fontan palliation and available chest CT examination. Patients were evaluated for (1) type of congenital heart disease and prior operations;(2) indication for initial CT evaluation;(3) route of contrast medium administration for the initial CT examination and resulting diagnosis;(4) whether or not anticoagulation therapy was initiated; and (5) final diagnosis and treatment plan. Results: The query of the ACHD database resulted in 28 individuals or patients with Fontan palliation (superior and inferior venae cavae anastomosed to the pulmonary arteries). Of these, 19 patients with Fontan physiology underwent CTA of the pulmonary circulation, and 17 had suboptimal imaging studies. Unfortunately, seven of these 17 patients (41%) were started on anticoagulation therapy due to a diagnosis of pulmonary embolism that was later excluded. Conclusion: Patients with single-ventricle/Fontan physiology are at risk of thromboembolic disease. Therefore, studies evaluating their complex anatomy must be performed with the optimal imaging protocol to ensure diagnostic accuracy, which is best achieved with dual-injection of an upper and lower extremity central vein. - Highlights: • The adult congenital heart disease population is growing. • Many of these patients have single ventricle/Fontan physiology. • Patients with Fontan physiology are at increased risk for

  5. Sustained neuroprotection from a single intravitreal injection of PGJ₂ in a nonhuman primate model of nonarteritic anterior ischemic optic neuropathy.

    Science.gov (United States)

    Miller, Neil R; Johnson, Mary A; Nolan, Theresa; Guo, Yan; Bernstein, Alexander M; Bernstein, Steven L

    2014-10-08

    Prostaglandin J₂ (PGJ₂) is neuroprotective in a murine model of nonarteritic anterior ischemic optic neuropathy (NAION). After assessing for potential toxicity, we evaluated the efficacy of a single intravitreal (IVT) injection of PGJ₂ in a nonhuman primate model of NAION (pNAION). We assessed PGJ₂ toxicity by administering it as a single high-dose intravenous (IV) injection, consecutive daily high-dose IV injections, or a single IVT injection in one eye of five adult rhesus monkeys. To assess efficacy, we induced pNAION in one eye of five adult male rhesus monkeys using a laser-activated rose bengal induction method. We then injected the eye with either PGJ₂ or phosphate-buffered saline (PBS) intravitreally immediately or 5 hours post induction. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in all animals prior to induction and at 1 day, 1 week, 2 weeks, and 4 weeks after induction. Following analysis of the first eye, we induced pNAION in the contralateral eye and then injected either PGJ₂ or PBS. We euthanized all animals 5 weeks after final assessment of the fellow eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves. PGJ₂ caused no permanent systemic toxicity regardless of the amount injected or route of delivery, and there was no evidence of any ocular toxicity with the dose of PGJ₂ used in efficacy studies. Transient reduction in the amplitudes of the visual evoked potentials and the N95 component of the pattern electroretinogram (PERG) occurred after both IV and IVT administration of high doses of PGJ₂; however, the amplitudes returned to normal in all animals within 1 week. In all eyes, a single IVT dose of PGJ₂ administered immediately or shortly after induction of pNAION resulted in a significant reduction of clinical, electrophysiological, and histological damage compared

  6. Intratracheal transplantation of endothelial progenitor cells attenuates smoking-induced COPD in mice

    Directory of Open Access Journals (Sweden)

    Shi Z

    2017-03-01

    Full Text Available Zhihui Shi,1 Yan Chen,1 Jun Cao,2 Huihui Zeng,1 Yue Yang,1 Ping Chen,1 Hong Luo,1 Hong Peng,1 Shan Cai,1 Chaxiang Guan3 1Department of Internal Medicine, Division of Respiratory Disease, The Second Xiangya Hospital, Central-South University, 2Department of Internal Medicine, Division of Respiratory Disease, The People’s Hospital of Hunan Province, 3Department of Physiology, Xiangya Medical School, Central-South University, Changsha, Hunan, People’s Republic of China Background: Endothelial progenitor cells (EPCs might play a protective role in COPD. The aim of this study was to investigate whether intratracheal allogeneic transplantation of bone-marrow-derived EPCs would attenuate the development of smoking-induced COPD in mice.Methods: Isolated mononuclear cells from the bone marrow of C57BL/6J mice were cultured in endothelial cell growth medium-2 for 10 days, yielding EPCs. A murine model of COPD was established by passive 90-day exposure of cigarette smoke. On day 30, EPCs or phosphate-buffered saline alone was administered into the trachea. On day 90, EPCs or 30 µL phosphate-buffered saline alone was administered into the trachea, and on day 120, inflammatory cells, antioxidant activity, apoptosis, matrix metalloproteinase (MMP-2, and MMP-9 were measured.Results: After EPC treatment, the lung function of the mice had improved compared with the untreated mice. Mean linear intercept and destructive index were reduced in the EPCs-treated group compared with the untreated group. In addition, the EPCs-treated mice exhibited less antioxidant activity in bronchoalveolar lavage fluid compared with the untreated mice. Moreover, decreased activities of MMP-2, MMP-9, and TUNEL-positive cells in lung tissues were detected in EPCs-treated mice.Conclusion: Intratracheal transplantation of EPCs attenuated the development of pulmonary emphysema and lung function disorder probably by alleviating inflammatory infiltration, decelerating apoptosis

  7. Recovery of rat muscle size but not function more than 1 year after a single botulinum toxin injection.

    Science.gov (United States)

    Ward, Samuel R; Minamoto, Viviane B; Suzuki, Kentaro P; Hulst, Jonah B; Bremner, Shannon N; Lieber, Richard L

    2018-03-01

    Neurotoxin injection is used to treat a wide variety of neuromuscular disorders. The purpose of this study was to measure the functional and structural properties of botulinum toxin-injected adult rat skeletal muscle over nearly the entire lifespan. Ten groups of animals were subjected to either neurotoxin injection [Botox, Type A (BT-A); Allergan, Irvine, California] or saline solution injection. Neurotoxin-injected animals (n = 90) were analyzed at different time-points: 1 week; 1 month; 3 months; 6 months; 12 months; or 18 months. In spite of the recovery of structural features, such as muscle mass and fiber area, dorsiflexion torque production remained significantly depressed by 25%, even at 12 months after neurotoxin injection. The data demonstrate that, after a single BT-A injection, although gross muscle morphology recovered over a 12-month time period, loss of contractile function did not recover. Muscle Nerve 57: 435-441, 2018. © 2017 Wiley Periodicals, Inc.

  8. Recurrent pregnancy-related upper airway obstruction caused by intratracheal ectopic thyroid tissue

    DEFF Research Database (Denmark)

    Døssing, H; Jørgensen, K E; Oster-Jørgensen, E

    1999-01-01

    An unusual case of recurrent pregnancy-related thyroid growth stimulation is reported. A 27-year-old euthyroid woman had pulmonary symptoms, thought to be asthma during her first pregnancy, that improved postpartum. Bronchodilatators had no effect and symptoms recurred from gestational week 22...... during her second pregnancy. Her 58-mL multinodular goiter (by ultrasound) was not thought to be responsible for her upper airway symptoms. Therefore, fiber laryngoscopy and computed tomographic (CT) scan were performed and revealed a 20 x 15 x 10 mm intratracheal tumor. After tracheostomy...... developed normally. We believe that this case illustrates the recurrent effect of pregnancy-related thyroid tissue stimulation by a combination of increasing human chorionic gonadotropin (hCG) stimulation and iodine deficiency in a borderline iodine-deficient region. This is the first report on symptomatic...

  9. GSK1265744 pharmacokinetics in plasma and tissue after single-dose long-acting injectable administration in healthy subjects.

    Science.gov (United States)

    Spreen, William; Ford, Susan L; Chen, Shuguang; Wilfret, David; Margolis, David; Gould, Elizabeth; Piscitelli, Stephen

    2014-12-15

    GSK1265744 (744) is an HIV-1 integrase inhibitor in clinical development as a long-acting (LA) injectable formulation. This study evaluated plasma and tissue pharmacokinetics after single-dose administration of 744 LA administered by intramuscular (IM) or subcutaneous injections. This was a phase I, open-label, 9-cohort, parallel study of 744 in healthy subjects. 744 was administered as a 200 mg/mL nanosuspension at doses of 100-800 mg IM and 100-400 mg subcutaneous. Eight (6 active and 2 placebo) male and female subjects participated in each of the first 7 cohorts. All 8 subjects, 4 males and 4 females, received active 744 LA in cohorts 8 and 9 and underwent rectal and cervicovaginal tissue sampling, respectively. Plasma pharmacokinetic sampling was performed for a minimum of 12 weeks or until 744 concentrations were ≤0.1 μg/mL. Rectal and cervicovaginal tissue biopsies were performed at weeks 2 and 8 (cohort 8) and weeks 4 and 12 (cohort 9). 744 LA was generally safe and well tolerated after single injections. A majority of subjects reported injection site reactions, all graded as mild in intensity. Plasma concentration-time profiles were prolonged with measureable concentrations up to 52 weeks after dosing. 744 LA 800 mg IM achieved mean concentrations above protein adjusted-IC90 for approximately 16 weeks. Rectal and cervicovaginal tissue concentrations ranged from injection has potential application as a monthly or less frequent HIV treatment or prevention agent.

  10. Critical firing and misfiring boundary in a spark ignition methanol engine during cold start based on single cycle fuel injection

    International Nuclear Information System (INIS)

    Li, Zhaohui; Gong, Changming; Qu, Xiang; Liu, Fenghua; Sun, Jingzhen; Wang, Kang; Li, Yufeng

    2015-01-01

    The influence of the mass of methanol injected per cycle, ambient temperature, injection and ignition timing, preheating methods, and supplying additional liquefied petroleum gas (LPG) injection into the intake manifold on the critical firing and misfiring boundary of an electronically injection controlled spark ignition (SI) methanol engine during cold start were investigated experimentally based on a single cycle fuel injection with cycle-by-cycle control strategy. The critical firing and misfiring boundary was restricted by all parameters. For ambient temperatures below 16 °C, methanol engines must use auxiliary start-aids during cold start. Optimal control of the methanol injection and ignition timing can realize ideal next cycle firing combustion after injection. Resistance wire and glow plug preheating can provide critical firing down to ambient temperatures of 5 °C and 0 °C, respectively. Using an additional LPG injection into the intake manifold can provide critical firing down to an ambient temperature of −13 °C during cold start. As the ambient temperature decreases, the optimal angle difference between methanol injection timing and LPG injection timing for critical firing of a methanol engine increases rapidly during cold start. - Highlights: • A single cycle fuel injection and cycle-by-cycle control strategy are used to study. • In-cylinder pressure and instantaneous speed were used to determine firing boundary. • For the ambient temperatures below 16 °C, an auxiliary start-aids must be used. • A preheating and additional LPG were used to expand critical firing boundary. • Additional LPG can result in critical firing down to ambient temperature of −13 °C

  11. All-in-polymer injection molded device for single cell capture using multilevel silicon master fabrication

    DEFF Research Database (Denmark)

    Tanzi, S.; Larsen, S.T.; Matteucci, M.

    2012-01-01

    This work demonstrates a novel all-in-polymer device for single cell capture applicable for biological recordings. The chip is injection molded and comprises a "cornered" (non planar) aperture. It has been demonstrated how cornered apertures are straightforward to mold in PDMS [1,2]. In this stud...

  12. Hepatic microsomal phospholipids in rats exposed intratracheally to coal fly ash

    International Nuclear Information System (INIS)

    Srivastava, P.K.; Chauhan, S.S.; Misra, U.K.

    1986-01-01

    The effects of intratracheal administration of fly ash (50 mg/kg body weight, daily for 7 days) on hepatic microsomal phospholipid metabolism has been studied in rats using various phospholipid precursors, viz NaH 2 32 PO 4 , (methyl- 14 C)-choline, and (methyl- 14 C)-methionine. Fly ash administration significantly increased microsomal phosphatidylcholine (PC), and lysophosphatidylcholine (LPC). The incorporation of NaH 2 32 PO 4 into total liver phospholipids, PC and Phosphatidyl ethanolamine (PE) was significantly increased in fly ash-treated rats as compared to the control. Fly ash administration also increased the incorporation of (methyl- 14 C)-choline into microsomal PC. Incorporation of (methyl- 14 C)-methionine into microsomal PC was not affected. Fly ash administration decreased the per cent distribution of arachidonic acid in PC and PE and increased that of oleic acid in PC and of linoleic acid in PE. (orig.)

  13. Pharmacokinetics of enrofloxacin and ciprofloxacin in Atlantic horseshoe crabs (Limulus polyphemus) after single injection.

    Science.gov (United States)

    Kirby, A; Lewbart, G A; Hancock-Ronemus, A; Papich, M G

    2018-04-01

    The pharmacokinetics of enrofloxacin and the metabolite ciprofloxacin were studied in horseshoe crabs after a single injection of 5 mg/kg. Twelve Atlantic horseshoe crabs (Limulus polyphemus) of undetermined age were injected with enrofloxacin into the dorsal cardiac sinus. Hemolymph samples were collected by syringe and needle at regular intervals for 120 hr. Samples were analyzed by high-pressure liquid chromatography and compartmental analysis performed on the results. Following injection, the elimination half-life (T½), peak concentration, area under the curve (AUC), and volume of distribution (VD) for enrofloxacin were 27.9 (29.13) hr, 8.98 (18.09) μg/ml, 367.38 (35.41) hr μg/ml, and 0.575 (20.48) L/kg, respectively (mean value, CV%). For ciprofloxacin, the elimination T½, peak concentration, and AUC were 61.36 (34.55) hr, 2.34 (24.11) μg/ml, and 304.46 (24.69) μg hr/ml. In these animals, the ciprofloxacin concentrations comprised an average of 45.8% of the total fluoroquinolone concentrations, which is substantial compared to other marine invertebrates. The total AUC produced (sum of enrofloxacin and ciprofloxacin) was 682.69 ± 180.61 μg hr/ml. Concentrations that were achieved after a single dose of 5 mg/kg horseshoe crabs were sufficient to treat bacteria susceptible to enrofloxacin and ciprofloxacin. © 2017 John Wiley & Sons Ltd.

  14. Multiple PRP injections are more effective than single injections and hyaluronic acid in knees with early osteoarthritis: a randomized, double-blind, placebo-controlled trial.

    Science.gov (United States)

    Görmeli, Gökay; Görmeli, Cemile Ayşe; Ataoglu, Baybars; Çolak, Cemil; Aslantürk, Okan; Ertem, Kadir

    2017-03-01

    To compare the effectiveness of intraarticular (IA) multiple and single platelet-rich plasma (PRP) injections as well as hyaluronic acid (HA) injections in different stages of osteoarthritis (OA) of the knee. A total of 162 patients with different stages of knee OA were randomly divided into four groups receiving 3 IA doses of PRP, one dose of PRP, one dose of HA or a saline injection (control). Then, each group was subdivided into two groups: early OA (Kellgren-Lawrence grade 0 with cartilage degeneration or grade I-III) and advanced OA (Kellgren-Lawrence grade IV). The patients were evaluated before the injection and at the 6-month follow-ups using the EuroQol visual analogue scale (EQ-VAS) and International Knee Documentation Committee (IKDC) subjective scores. Adverse events and patient satisfaction were recorded. There was a statistically significant improvement in the IKDC and EQ-VAS scores in all the treatment groups compared with the control group. The knee scores of patients treated with three PRP injections were significantly better than those patients of the other groups. There was no significant difference in the scores of patients injected with one dose of PRP or HA. In the early OA subgroups, significantly better clinical results were achieved in the patients treated with three PRP injections, but there was no significant difference in the clinical results of patients with advanced OA among the treatment groups. The clinical results of this study suggest IA PRP and HA treatment for all stages of knee OA. For patients with early OA, multiple (3) PRP injections are useful in achieving better clinical results. For patients with advanced OA, multiple injections do not significantly improve the results of patients in any group. I.

  15. Single injection thoracic paravertebral block (TPVB for breast surgery in morbidly obese patient

    Directory of Open Access Journals (Sweden)

    Anita Kulkarni

    2017-01-01

    Full Text Available Morbidly obese (MO patients with associated restrictive airway disease, obstructive sleep apnea, and coronary artery disease pose challenge to an anesthesiologist. Regional block combined with general anesthesia (GA is the anesthetic technique of choice as it will decrease the requirement of opioids, anesthetics, and postoperative respiratory depression. A MO patient for modified radical mastectomy was successfully managed with single-injection thoracic paravertebral block and conventional GA.

  16. Knee Viscosupplementation: Cost-Effectiveness Analysis between Stabilized Hyaluronic Acid in a Single Injection versus Five Injections of Standard Hyaluronic Acid

    Directory of Open Access Journals (Sweden)

    Francisco J. Estades-Rubio

    2017-03-01

    Full Text Available Given the wide difference in price per vial between various presentations of hyaluronic acid, this study seeks to compare the effectiveness and treatment cost of stabilized hyaluronic acid (NASHA in a single injection with standard preparations of hyaluronic acid (HA in five injections in osteoarthritis (OA of the knee. Fifty-four patients with knee osteoarthritis (Kellgren–Lawrence Grade II and III and the Western Ontario and McMaster Universities Arthritis Index (WOMAC pain score greater than 7, with a homogeneous distribution of age, sex, BMI, and duration of disease, were included in this study. Patients were randomized into two groups: Group I was treated with NASHA (Durolane® and Group II with HA (Go-ON®. Patient’s evolution was followed up at the 1st, 2nd, 4th, 8th, 12th, and 26th week after treatment. A statistically significant improvement in WOMAC score was observed for patients treated with NASHA versus those who received HA at Week 26. In addition, the need for analgesia was significantly reduced at Week 26 in the NASHA-treated group. Finally, the economic analysis showed an increased cost of overall treatment with HA injections. Our data support the use of the NASHA class of products in the treatment of knee OA.

  17. Knee Viscosupplementation: Cost-Effectiveness Analysis between Stabilized Hyaluronic Acid in a Single Injection versus Five Injections of Standard Hyaluronic Acid.

    Science.gov (United States)

    Estades-Rubio, Francisco J; Reyes-Martín, Alvaro; Morales-Marcos, Victor; García-Piriz, Mercedes; García-Vera, Juan J; Perán, Macarena; Marchal, Juan A; Montañez-Heredia, Elvira

    2017-03-17

    Given the wide difference in price per vial between various presentations of hyaluronic acid, this study seeks to compare the effectiveness and treatment cost of stabilized hyaluronic acid (NASHA) in a single injection with standard preparations of hyaluronic acid (HA) in five injections in osteoarthritis (OA) of the knee. Fifty-four patients with knee osteoarthritis (Kellgren-Lawrence Grade II and III) and the Western Ontario and McMaster Universities Arthritis Index (WOMAC) pain score greater than 7, with a homogeneous distribution of age, sex, BMI, and duration of disease, were included in this study. Patients were randomized into two groups: Group I was treated with NASHA (Durolane ® ) and Group II with HA (Go-ON ® ). Patient's evolution was followed up at the 1st, 2nd, 4th, 8th, 12th, and 26th week after treatment. A statistically significant improvement in WOMAC score was observed for patients treated with NASHA versus those who received HA at Week 26. In addition, the need for analgesia was significantly reduced at Week 26 in the NASHA-treated group. Finally, the economic analysis showed an increased cost of overall treatment with HA injections. Our data support the use of the NASHA class of products in the treatment of knee OA.

  18. Will a single periarticular lidocaine-corticosteroid injection improve the clinical efficacy of intraarticular hyaluronic acid treatment of symptomatic knee osteoarthritis?

    Science.gov (United States)

    Ertürk, Cemil; Altay, Mehmet Akif; Altay, Nuray; Kalender, Ali Murat; Öztürk, İbrahim Avşin

    2016-11-01

    A local injection of corticosteroid-lidocaine into the periarticular soft tissue structures is used commonly for rapid pain relief. It is hypothesized that knee pain associated with knee osteoarthritis would be relieved quickly and effectively in patients receiving intraarticular hyaluronic acid combined with a periarticular lidocaine-corticosteroid injection. To test this hypothesis, the clinical effect of the combined treatment with hyaluronic acid injection alone in patients with symptomatic knee osteoarthritis as compared in this prospective single-blinded randomized trial. This study included 70 patients. Group 1 (n = 35) received intraarticular hyaluronic acid injections only, whereas group 2 (n = 35) received intraarticular hyaluronic acid injections combined with a single local injection of corticosteroid-lidocaine. Injections were administered to the most painful areas of the anterior or posterior medial condyle of the femur or tibia. The outcome was measured by independent assessors (blinded to treatment) using a linear VAS pain scale and WOMAC and HSS knee scores. Assessments were performed at baseline and at 1, 3, 6, 12, 26, and 52 weeks. During the first 3 weeks, group 2 patients showed significantly better all scores than did group 1 patients (p hyaluronic acid alone in patients with knee osteoarthritis and can be considered a useful adjunctive treatment modality. This combined method may provide early return to patient's daily activity. Therapeutic study, Level I.

  19. Sustained Neuroprotection From a Single Intravitreal Injection of PGJ2 in a Nonhuman Primate Model of Nonarteritic Anterior Ischemic Optic Neuropathy

    Science.gov (United States)

    Miller, Neil R.; Johnson, Mary A.; Nolan, Theresa; Guo, Yan; Bernstein, Alexander M.; Bernstein, Steven L.

    2014-01-01

    Purpose. Prostaglandin J2 (PGJ2) is neuroprotective in a murine model of nonarteritic anterior ischemic optic neuropathy (NAION). After assessing for potential toxicity, we evaluated the efficacy of a single intravitreal (IVT) injection of PGJ2 in a nonhuman primate model of NAION (pNAION). Methods. We assessed PGJ2 toxicity by administering it as a single high-dose intravenous (IV) injection, consecutive daily high-dose IV injections, or a single IVT injection in one eye of five adult rhesus monkeys. To assess efficacy, we induced pNAION in one eye of five adult male rhesus monkeys using a laser-activated rose bengal induction method. We then injected the eye with either PGJ2 or phosphate-buffered saline (PBS) intravitreally immediately or 5 hours post induction. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in all animals prior to induction and at 1 day, 1 week, 2 weeks, and 4 weeks after induction. Following analysis of the first eye, we induced pNAION in the contralateral eye and then injected either PGJ2 or PBS. We euthanized all animals 5 weeks after final assessment of the fellow eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves. Results. Toxicity: PGJ2 caused no permanent systemic toxicity regardless of the amount injected or route of delivery, and there was no evidence of any ocular toxicity with the dose of PGJ2 used in efficacy studies. Transient reduction in the amplitudes of the visual evoked potentials and the N95 component of the pattern electroretinogram (PERG) occurred after both IV and IVT administration of high doses of PGJ2; however, the amplitudes returned to normal in all animals within 1 week. Efficacy: In all eyes, a single IVT dose of PGJ2 administered immediately or shortly after induction of pNAION resulted in a significant reduction of clinical, electrophysiological, and

  20. Intraperitoneal Injection Is Not a Suitable Administration Route for Single-Walled Carbon Nanotubes in Biomedical Applications.

    Science.gov (United States)

    Liu, Xudong; Guo, Qing; Zhang, Yuchao; Li, Jinquan; Li, Rui; Wu, Yang; Ma, Ping; Yang, Xu

    2016-01-01

    Given the extensive application of carbon nanotubes (CNTs) in biomedical fields, there is increasing concern regarding unintentional health impacts. Research into safe usage is therefore increasingly necessary. This study investigated the responses of the mouse brain to single-walled CNTs (SWCNTs) delivered via intraperitoneal (IP) injection and compared these results with the previous study where SWCNTs were delivered via intravenous (IV) injection so as to explore which administration route is potentially better for SWCNTs application. This study suggests SWCNTs delivered via IP injection can have negative effects on the mouse brain through oxidative stress and inflammation at high concentration exposure, but these responses were not consistent and showed no dose-dependent effect. In a previous study, the results showed that IV-delivered SWCNTs induced a more consistent and dose-dependent effect. The comparison of the 2 studies suggested that using SWCNTs at a safe dosage delivered via IV injection may be a better administration route for SWCNTs in biomedical applications.

  1. Sustained neuroprotection from a single intravitreal injection of PGJ2 in a rodent model of anterior ischemic optic neuropathy.

    Science.gov (United States)

    Touitou, Valerie; Johnson, Mary A; Guo, Yan; Miller, Neil R; Bernstein, Steven L

    2013-11-11

    Nonarteritic anterior ischemic optic neuropathy (NAION) is the most common cause of sudden optic nerve-related vision loss in persons older than 50 in the United States. There currently is no treatment for this disorder. We previously showed that systemic administration of 15-deoxy, delta (12, 14) prostaglandin J2 (PGJ2) is neuroprotective in our rodent model of AION (rAION). In this study, we determined if a single intravitreal (IVT) injection of PGJ2 is neuroprotective after rAION, and if this method of administration is toxic to the retina, optic nerve, or both. TOXICITY was assessed after a single IVT injection of PGJ2 in one eye and PBS in the contralateral eye of normal, adult Long-Evans rats. EFFICACY was assessed by inducing rAION in one eye and injecting either PGJ2 or vehicle immediately following induction, with the fellow eye serving as naïve control. Visual evoked potentials (VEPs) and ERGs were performed before induction and at specific intervals thereafter. Animals were euthanized 30 days after induction, after which immunohistochemistry, transmission electron microscopy, and quantitative stereology of retinal ganglion cell (RGC) numbers were performed. IVT PGJ2 did not alter the VEP or ERG compared with PBS-injected control eyes, and neither IVT PGJ2 nor PBS reduced overall RGC numbers. IVT PGJ2 preserved VEP amplitude, reduced optic nerve edema, and resulted in significant preservation of RGCs and axons in eyes with rAION. A single IVT injection of PGJ2 is nontoxic to the retina and optic nerve and neuroprotective when given immediately after rAION induction.

  2. Performance of single cylinder, direct injection Diesel engine using water fuel emulsions

    International Nuclear Information System (INIS)

    Abu-Zaid, M.

    2004-01-01

    A single cylinder Diesel engine study of water-in-Diesel emulsions was conducted to investigate the effect of water emulsification on the engine performance and gases exhaust temperature. Emulsified Diesel fuels of 0, 5, 10, 15 and 20 water/Diesel ratios by volume, were used in a single cylinder, direct injection Diesel engine, operating at 1200-3300 rpm. The results indicate that the addition of water in the form of emulsion improves combustion efficiency. The engine torque, power and brake thermal efficiency increase as the water percentage in the emulsion increases. The average increase in the brake thermal efficiency for 20% water emulsion is approximately 3.5% over the use of Diesel for the engine speed range studied. The proper brake specific fuel consumption and gases exhaust temperature decrease as the percentage of water in the emulsion increases

  3. Distribution of 14C-lindane in the rat after a single dose intraperitoneal and intravenous injection

    International Nuclear Information System (INIS)

    Lievremont, Maurice; Le Flohic, J.-F.; Pascaud, Marc

    1981-01-01

    14 C-Lindane retentions in rat tissues were studied until 24 hrs after a single dose pesticide administration. Each organ shows particular kinetics. Adipose tissue is the most active in pesticide fixation but the lungs retain momentarily a large fraction of Lindane after intravenous injection [fr

  4. Review: study of single-pellet injection experiments and development of pellet injector in JFT-2M

    International Nuclear Information System (INIS)

    Kasai, Satoshi; Miura, Yukitoshi; Hasegawa, Kouichi; Sengoku, Seio

    1987-10-01

    The single pellet injector developed for JFT-2M and the improvement of plasma characteristics in the auxiliary-heated discharges by single-pellet injection are reviewed for the period 1982 - 1986. The pellet injector is a pneumatic type and the designed pellet size is 1.65 mmD x 1.65 mmL and 1 mmD x 1 mmL. The hydrogen, deuterium and mixed (H 2 + D 2 ) pellets can be produced with good reproducibility. Maximum pellet velocity is about 970 m/s (pellet is deuterium and propellant gas is hydrogen). In the pellet injection experiments into auxiliary-heated (NB, ICRF) divertor or limiter discharges, the plasma confinement time is improved by a factor of 1.4 - 1.7 compared with the confinement time in the Ohmic discharges. The achieved confinement time is longer than that on the high confinement mode (H-mode) in gas fueled discharges, although the phenomena are transient. (author)

  5. Assessment of the efficacy and safety of single platelet-rich plasma injection on different types and grades of facial wrinkles.

    Science.gov (United States)

    Elnehrawy, Naema Y; Ibrahim, Zeinab A; Eltoukhy, Azza M; Nagy, Hala M

    2017-03-01

    Platelet-rich plasma (PRP) is considered as a growing modality for tissue regeneration and a developing research area for clinicians and researchers. PRP injection treatment provides supraphysiological concentrations of growth factors that may help in accelerated tissue remodeling and regeneration. To evaluate the efficacy and safety of single autologous PRP intradermal injection for treatment of facial wrinkles and for facial rejuvenation. A total of 20 subjects with different types of facial wrinkles were included in this study. All subjects received single PRP intradermal injection and were clinically assessed before and after treatment for a period of 8 weeks using Wrinkle Severity Rating Scale (WSRS), Skin Homogeneity and Texture (SHnT) Scale, Physician Assessment Scale, and Subject Satisfaction Scale. The mean value of WSRS reduced from 2.90 ± 0.91 before treatment to 2.10 ± 0.79 after 8 weeks of treatment. The most significant results were with younger subjects that have mild and moderate wrinkles of the nasolabial folds (NLFs). Fourteen of seventeen subjects with NLFs showed more than 25% improvement in their appearance. Side effects of PRP treatment were minimal to mild and with excellent tolerability. Single PRP intradermal injection is well tolerated and capable of rejuvenating the face and producing a significant correction of wrinkles especially the NLFs. © 2016 Wiley Periodicals, Inc.

  6. Diffuse chorioretinal atrophy after a single standard low- dose intravitreal melphalan injection in a child with retinoblastoma: a case report.

    Science.gov (United States)

    Chao, An- Ning; Kao, Ling-Yuh; Liu, Laura; Wang, Nan-Kai

    2016-03-15

    Controlling retinoblastoma with seeding is challenging despite advances in treatment modalities. Intravitreal melphalan is an alternative to external beam radiation or enucleation for recurrent or refractory vitreous seeds. Significant ocular side effects following intravitreal melphalan injections are uncommon. Complications have been reported in eyes receiving higher concentrations of melphalan and repetitive injections. We report a case in which diffuse chorioretinal atrophy was developed at the injection site after a single, standard low-dose intravitreal melphalan injection. A 12-month-old female child without a family history of retinoblastoma presented with unilateral group C retinoblastoma in her right eye. A solitary tumour with retinal breaks on the tumour surface, and vitreous seeds overlying the tumour were observed at the 8 o'clock position of the retina. After two cycles of intra-arterial chemotherapy with melphalan, the main tumour displayed significant regression, but the vitreous seeds overlying the main tumour were still active. Because of the persistence of vitreous seeds and the inadequate response to intra-arterial melphalan treatment, intravitreal melphalan (8 μg in 0.05 mL) was injected using a 32-gauge needle 2.5 mm from the 5 o'clock position of the limbus, the meridian opposite to the vitreous seeds. After 1 month, the retina around the injection site demonstrated diffuse retinal pigment epithelium alterations with dense hard exudates. Although the main retinal mass, and vitreous seeds resolved, the hard exudates persisted for more than 2 years after the single low-dose melphalan injection. Intravitreal melphalan injections should be cautiously used for eyes with refractory seeds, particularly when multiple injections are required to control retinoblastoma seeds. Dose- related retinal toxicity could occur in pre-treated eyes even when a relatively low standard dose is used. Such patients should be followed up closely to monitor the

  7. UV-visible digital imaging of split injection in a Gasoline Direct Injection engine

    Directory of Open Access Journals (Sweden)

    Merola Simona Silvia

    2015-01-01

    Full Text Available Ever tighter limits on pollutant emissions and the need to improve energy conversion efficiency have made the application of gasoline direct injection (GDI feasible for a much wider scale of spark ignition engines. Changing the way fuel is delivered to the engine has thus provided increased flexibility but also challenges, such as higher particulate emissions. Therefore, alternative injection control strategies need to be investigated in order to obtain optimum performance and reduced environmental impact. In this study, experiments were carried out on a single-cylinder GDI optical engine fuelled with commercial gasoline in lean-burn conditions. The single-cylinder was equipped with the head of a commercial turbocharged engine with similar geometrical specifications (bore, stroke, compression ratio and wall guided fuel injection. Optical accessibility was ensured through a conventional elongated hollow Bowditch piston and an optical crown, accommodating a fused-silica window. Experimental tests were performed at fixed engine speed and injection pressure, whereas the injection timing and the number of injections were adjusted to investigate their influence on combustion and emissions. UV-visible digital imaging was applied in order to follow the combustion process, from ignition to the late combustion phase. All the optical data were correlated with thermodynamic analysis and measurements of exhaust emissions. Split injection strategies (i.e. two injections per cycle with respect to single injection increased combustion efficiency and stability thanks to an improvement of fuel air mixing. As a consequence, significant reduction in soot formation and exhaust emission with acceptable penalty in terms of HC and NOx were measured.

  8. High-power actively Q-switched single-mode 1342 nm Nd:YVO4 ring laser, injection-locked by a cw single-frequency microchip laser.

    Science.gov (United States)

    Koch, Peter; Bartschke, Juergen; L'huillier, Johannes A

    2015-11-30

    In this paper we report on the realization of a single-mode Q-switched Nd:YVO4 ring laser at 1342 nm. Unidirectional and single-mode operation of the ring laser is achieved by injection-locking with a continuous wave Nd:YVO4 microchip laser, emitting a single-frequency power of up to 40 mW. The ring laser provides a single-mode power of 13.9 W at 10 kHz pulse repetition frequency with a pulse duration of 18.2 ns and an excellent beam quality (M2 laser, a power of 8.7 W at 671 nm with a pulse duration of 14.8 ns and a beam propagation factor of M2 < 1.1 is obtained. The 671 nm radiation features a long-term spectral width of 75 MHz.

  9. Fat injection to correct contour deformities of the reconstructed breast: a single surgeon experience

    Directory of Open Access Journals (Sweden)

    Youssef Tahiri

    2015-06-01

    Full Text Available Aim: Autologous fat grafting has gained acceptance as a technique to improve aesthetic outcomes in breast reconstruction. The purpose of this study was to share our clinical experience using autologous fat injection to correct contour deformities during breast reconstruction. Methods: A single surgeon, prospectively maintained database of patients who underwent autologous fat injection during breast reconstruction from January 2008 to November 2013 at McGill University Health Center was reviewed. Patient characteristics, breast history, type of breast reconstruction, volume of fat injected, and complications were analyzed. Results: One hundred and twenty-four patients benefited from autologous fat injection from January 2008 to November 2013, for a total of 187 treated breasts. The patients were on average 49.3 years old (΁ 8.9 years. Fat was harvested from the medial thighs (20.5%, flanks (39.1%, medial thighs and flanks (2.9%, trochanters (13.3%, medial knees (2.7%, and abdomen (21.9%. An average of 49.25 mL of fat was injected into each reconstructed breast. A total of 187 breasts in 124 patients were lipo-infiltrated during the second stage of breast reconstruction. Thirteen breasts (in 12 separate patients were injected several years after having undergone lumpectomy and radiotherapy. Of the 187 treated breasts, 118 were reconstructed with expanders to implants, 45 with deep inferior epigastric perforator flaps, 9 with latissimus dorsi flaps with implants, 4 with transverse rectus abdominis myocutaneous flaps, and 13 had previously undergone lumpectomy and radiotherapy. Six complications were noted in the entire series, for a rate of 3.2%. All were in previously radiated breasts. Average follow-up time was 12 months (range: 2-36 months. Conclusion: Fat injection continues to grow in popularity as an adjunct to breast reconstruction. Our experience demonstrates a low complication rate as compared to most surgical interventions of the breast

  10. Gene expression profiling in rat kidney after intratracheal exposure to cadmium-doped nanoparticles

    Science.gov (United States)

    Coccini, Teresa; Roda, Elisa; Fabbri, Marco; Sacco, Maria Grazia; Gribaldo, Laura; Manzo, Luigi

    2012-08-01

    While nephrotoxicity of cadmium is well documented, very limited information exists on renal effects of exposure to cadmium-containing nanomaterials. In this work, "omics" methodologies have been used to assess the action of cadmium-containing silica nanoparticles (Cd-SiNPs) in the kidney of Sprague-Dawley rats exposed intratracheally. Groups of animals received a single dose of Cd-SiNPs (1 mg/rat), CdCl2 (400 μg/rat) or 0.1 ml saline (control). Renal gene expression was evaluated 7 and 30 days post exposure by DNA microarray technology using the Agilent Whole Rat Genome Microarray 4x44K. Gene modulating effects were observed in kidney at both time periods after treatment with Cd-SiNPs. The number of differentially expressed genes being 139 and 153 at the post exposure days 7 and 30, respectively. Renal gene expression changes were also observed in the kidney of CdCl2-treated rats with a total of 253 and 70 probes modulated at 7 and 30 days, respectively. Analysis of renal gene expression profiles at day 7 indicated in both Cd-SiNP and CdCl2 groups downregulation of several cluster genes linked to immune function, oxidative stress, and inflammation processes. Differing from day 7, the majority of cluster gene categories modified by nanoparticles in kidney 30 days after dosing were genes implicated in cell regulation and apoptosis. Modest renal gene expression changes were observed at day 30 in rats treated with CdCl2. These results indicate that kidney may be a susceptible target for subtle long-lasting molecular alterations produced by cadmium nanoparticles locally instilled in the lung.

  11. Gene expression profiling in rat kidney after intratracheal exposure to cadmium-doped nanoparticles

    International Nuclear Information System (INIS)

    Coccini, Teresa; Roda, Elisa; Fabbri, Marco; Sacco, Maria Grazia; Gribaldo, Laura; Manzo, Luigi

    2012-01-01

    While nephrotoxicity of cadmium is well documented, very limited information exists on renal effects of exposure to cadmium-containing nanomaterials. In this work, “omics” methodologies have been used to assess the action of cadmium-containing silica nanoparticles (Cd-SiNPs) in the kidney of Sprague-Dawley rats exposed intratracheally. Groups of animals received a single dose of Cd-SiNPs (1 mg/rat), CdCl 2 (400 μg/rat) or 0.1 ml saline (control). Renal gene expression was evaluated 7 and 30 days post exposure by DNA microarray technology using the Agilent Whole Rat Genome Microarray 4x44K. Gene modulating effects were observed in kidney at both time periods after treatment with Cd-SiNPs. The number of differentially expressed genes being 139 and 153 at the post exposure days 7 and 30, respectively. Renal gene expression changes were also observed in the kidney of CdCl 2 -treated rats with a total of 253 and 70 probes modulated at 7 and 30 days, respectively. Analysis of renal gene expression profiles at day 7 indicated in both Cd-SiNP and CdCl 2 groups downregulation of several cluster genes linked to immune function, oxidative stress, and inflammation processes. Differing from day 7, the majority of cluster gene categories modified by nanoparticles in kidney 30 days after dosing were genes implicated in cell regulation and apoptosis. Modest renal gene expression changes were observed at day 30 in rats treated with CdCl 2 . These results indicate that kidney may be a susceptible target for subtle long-lasting molecular alterations produced by cadmium nanoparticles locally instilled in the lung.

  12. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  13. The comparison of knee osteoarthritis treatment with single-dose bone marrow-derived mononuclear cells vs. hyaluronic acid injections.

    Science.gov (United States)

    Goncars, Valdis; Jakobsons, Eriks; Blums, Kristaps; Briede, Ieva; Patetko, Liene; Erglis, Kristaps; Erglis, Martins; Kalnberzs, Konstantins; Muiznieks, Indrikis; Erglis, Andrejs

    2017-01-01

    The aim of this study was to compare treatment methods of the knee joint degenerative osteoarthritis, using autologous bone marrow-derived mononuclear cells and hyaluronic acid injections and observe prevalence of adverse effects in both groups. A prospective randomized controlled clinical trial was carried out. The analysis of pain and changes in osteoarthritis symptoms after a single intra-articular bone marrow-derived mononuclear cell injection into the knee joint in the Kellgren-Lawrence stage II-III osteoarthritis during the 12-month period were performed. The results were compared with the control group treated routinely by hyaluronic acid injections therapy. A therapy group of patients (n=28) received single bone marrow-derived mononuclear cell intra-articular injections. A control group of patients (n=28) was treated with a total of three sodium hyaluronate intra-articular injections each one performed a week apart. The clinical results were obtained using the Knee Osteoarthritis Outcome Score (KOOS) and the Knee Society Score (KSS) before and 3, 6, and 12 months after injection. A statistically significant improvement was observed in the mononuclear cell group over the starting point in all scores. At the endpoint at month 12, the KOOS score improved significantly (Phyaluronic acid versus the bone marrow-derived mononuclear cells group at time points 6 and 12 months demonstrated a statistically significant (Phyaluronic acid group. In both groups serious adverse effects were not observed. The intra-articular injection of bone marrow-derived mononuclear cells is a safe manipulation with no side effects during the 12-month period. This treatment provides statistically significant clinical improvement between the starting point and 1, 3, 6, and 12 months after. When compared to hyaluronic acid treatment, better pain relief in the long-term period of mononuclear cell group was observed. Copyright © 2017 The Lithuanian University of Health Sciences. Production

  14. Single injection 51Cr EDTA plasma clearance determination in children using capillary blood samples

    International Nuclear Information System (INIS)

    Broechner-Mortensen, J.; Christoffersen, J.

    1977-01-01

    The reliability of a determination of the total 51 Cr EDTA plasma clearance (e) (and with it the glomerular filtration rate), by a simplified single injection method (injected dose: 4.5 μCi per kg b.w.) using capillary blood samples (0.2 ml), was investigated in twenty children. Clearance values determined from capillary blood samples did not differ significantly from those measured simultaneously from venous blood samples, the mean ratio+-SD being 1.02+-0.06(n = 10). The reproducibility (total day-to-day variation) of E determined from capillary blood samples was 6.7% in children with decreased renal function (n = 3) and 6.9% in children with normal renal function (n = 7). The present data indicate that the use of capillary blood samples is an accurate and very precise approach for determination of E in children. (Auth.)

  15. A Single Intravitreal Injection of Ranibizumab Provides No Neuroprotection in a Nonhuman Primate Model of Moderate-to-Severe Nonarteritic Anterior Ischemic Optic Neuropathy.

    Science.gov (United States)

    Miller, Neil R; Johnson, Mary A; Nolan, Theresa; Guo, Yan; Bernstein, Steven L

    2015-12-01

    Ranibizumab, a vascular endothelial growth factor-antagonist, is said to be neuroprotective when injected intravitreally in patients with nonarteritic anterior ischemic optic neuropathy (NAION). We evaluated the efficacy of a single intravitreal (IVT) injection of ranibizumab in a nonhuman primate model of NAION (pNAION). We induced pNAION in one eye of four adult male rhesus monkeys using a laser-activated rose Bengal induction method. We then immediately injected the eye with either ranibizumab or normal saline (NS) intravitreally. We performed a clinical assessment, optical coherence tomography, electrophysiological testing, fundus photography, and fluorescein angiography in three of the animals (one animal developed significant retinal hemorrhages and, therefore, could not be analyzed completely) prior to induction, 1 day and 1, 2, and 4 weeks thereafter. Following the 4-week analysis of the first eye, we induced pNAION in the contralateral eye and then injected either ranibizumab or NS, whichever substance had not been injected in the first eye. We euthanized all animals 5 to 12 weeks after the final assessment of the second eye and performed both immunohistochemical and light and electron microscopic analyses of the retina and optic nerves of both eyes. A single IVT dose of ranibizumab administered immediately after induction of pNAION resulted in no significant reduction of clinical, electrophysiological, or histologic damage compared with vehicle-injected eyes. A single IVT dose of ranibizumab is not neuroprotective when administered immediately after induction of pNAION.

  16. Comparative Investigation on 0.4 inch SBLOCA Scenario with Single and Dual Train Passive Safety Injection Systems using SMART-ITL

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hyun-Sik; Bae, Hwang; Ryu, Sung-Uk; Jeon, Byong-Guk; Yang, Jin-Hwa; Yun, Eun-Koo; Choi, Nam-Hyun; Min, Kyoung-Ho; Shin, Yong-Cheol; Bang, Yoon-Gon; Kim, Myoung-Jun; Seo, Chan-Jong; Yi, Sung-Jae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    The Standard Design Approval (SDA) for SMART was certificated in 2012 at the Korea Atomic Energy Research Institute (KAERI). In December 2015, Saudi Arabia and Korea started conducting a three-year project of Pre-Project Engineering (PPE) to prepare a Preliminary Safety Analysis Report (PSAR) and to review the feasibility of constructing SMART reactors in Saudi Arabia. In addition, an Integral Test Loop for the SMART design (SMART-ITL, or FESTA) has been constructed and it finished its commissioning tests in 2012. Consequently, a set of Design Base Accident (DBA) scenarios have been simulated using SMART-ITL. In this paper, a comparative investigation was performed on 0.4 inch SBLOCA scenario with single and dual train passive safety injection systems using SMART-ITL. In this paper, the effect of the train number of PSIS on a SBLOCA scenario is investigated for a break size of 0.4 inch. The single and dual train tests show a similar trend in general but the injected water migrates slightly differently in the RV and is discharged through the break nozzle. The parameters of the RV pressure, RV water level, accumulated break mass, and injection flowrates from the CMT and SIT were compared. Compared with the single train test, the increased injection rates from the two trains of the PSIS during the dual train test raised the RV water level, ensuring the safety of the reactor core.

  17. Efficacy and safety of single injection of cross-linked sodium hyaluronate vs. three injections of high molecular weight sodium hyaluronate for osteoarthritis of the knee: a double-blind, randomized, multi-center, non-inferiority study.

    Science.gov (United States)

    Ha, Chul-Won; Park, Yong-Beom; Choi, Chong-Hyuk; Kyung, Hee-Soo; Lee, Ju-Hong; Yoo, Jae Doo; Yoo, Ju-Hyung; Choi, Choong-Hyeok; Kim, Chang-Wan; Kim, Hee-Chun; Oh, Kwang-Jun; Bin, Seong-Il; Lee, Myung Chul

    2017-05-26

    This randomized, double-blind, multi-center, non-inferiority trial was conducted to assess the efficacy and safety of a cross-linked hyaluronate (XLHA, single injection form) compared with a linear high molecular hyaluronate (HMWHA, thrice injection form) in patients with symptomatic knee osteoarthritis. Two hundred eighty seven patients with osteoarthritis (Kellgren-Lawrence grade I to III) were randomized to each group. Three weekly injections were given in both groups but two times of saline injections preceded XLHA injection to maintain double-blindness. Primary endpoint was the change of weight-bearing pain (WBP) at 12 weeks after the last injection. Secondary endpoints included Western Ontario and McMaster Universities Osteoarthritis index; patient's and investigator's global assessment; pain at rest, at night, or in motion; OMERACT-OARSI responder rate; proportion of patients achieving at least 20 mm or 40% decrease in WBP; and rate of rescue medicine use and its total consumption. Mean changes of WBP at 12 weeks after the last injection were -33.3 mm with XLHA and -29.2 mm with HMWHA, proving non-inferiority of XLHA to HMWHA as the lower bound of 95% CI (-1.9 mm, 10.1 mm) was well above the predefined margin (-10 mm). There were no significant between-group differences in all secondary endpoints. Injection site pain was the most common adverse event and no remarkable safety issue was identified. This study demonstrated that a single injection of XLHA was non-inferior to three weekly injections of HMWHA in terms of WBP reduction, and supports XLHA as an effective and safe treatment for knee osteoarthritis. ClinicalTrials.gov ( NCT01510535 ). This trial was registered on January 6, 2012.

  18. Intratracheal administration of fullerene nanoparticles activates splenic CD11b+ cells

    International Nuclear Information System (INIS)

    Ding, Ning; Kunugita, Naoki; Ichinose, Takamichi; Song, Yuan; Yokoyama, Mitsuru; Arashidani, Keiichi; Yoshida, Yasuhiro

    2011-01-01

    Highlights: → Fullerene administration triggered splenic responses. → Splenic responses occurred at different time-points than in the lung tissue. → CD11b + cells were demonstrated to function as responder cells to fullerene. - Abstract: Fullerene nanoparticles ('Fullerenes'), which are now widely used materials in daily life, have been demonstrated to induce elevated pulmonary inflammation in several animal models; however, the effects of fullerenes on the immune system are not fully understood. In the present study, mice received fullerenes intratracheally and were sacrificed at days 1, 6 and 42. Mice that received fullerenes exhibited increased proliferation of splenocytes and increased splenic production of IL-2 and TNF-α. Changes in the spleen in response to fullerene treatment occurred at different time-points than in the lung tissue. Furthermore, fullerenes induced CDK2 expression and activated NF-κB and NFAT in splenocytes at 6 days post-administration. Finally, CD11b + cells were demonstrated to function as responder cells to fullerene administration in the splenic inflammatory process. Taken together, in addition to the effects on pulmonary responses, fullerenes also modulate the immune system.

  19. Stability of methadone hydrochloride in 0.9% sodium chloride injection in single-dose plastic containers.

    Science.gov (United States)

    Denson, D D; Crews, J C; Grummich, K W; Stirm, E J; Sue, C A

    1991-03-01

    The stability of methadone hydrochloride in 0.9% sodium chloride injection in flexible polyvinyl chloride containers was studied. Commercially available methadone hydrochloride 20 mg/mL and 25-mL single-dose bags of 0.9% sodium chloride injection were used. Six samples each were prepared at methadone hydrochloride concentrations of 1, 2, and 5 mg/mL. The solutions were stored at room temperature and were not protected from light. Immediately after preparation and after two, three, and four weeks of storage, each of the 18 samples was divided into three aliquots, each of which was analyzed in duplicate for methadone hydrochloride concentration by gas chromatography. There was less than 10% change in methadone hydrochloride concentration in any sample throughout the four-week study period. Methadone hydrochloride at concentrations of 1, 2, and 5 mg/mL prepared in commercially available flexible polyvinyl chloride containers of 0.9% sodium chloride injection and stored at room temperature without deliberate protection from light is stable for at least four weeks.

  20. Observing Exoplanets with High-dispersion Coronagraphy. II. Demonstration of an Active Single-mode Fiber Injection Unit

    Energy Technology Data Exchange (ETDEWEB)

    Mawet, D.; Ruane, G.; Xuan, W.; Echeverri, D.; Klimovich, N.; Randolph, M.; Fucik, J.; Wang, J.; Dekany, R.; Delorme, J.-R. [Department of Astronomy, California Institute of Technology, 1200 East California Boulevard, MC 249-17, Pasadena, CA 91125 (United States); Wallace, J. K.; Vasisht, G.; Mennesson, B.; Choquet, E.; Serabyn, E., E-mail: dmawet@astro.caltech.edu [Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, CA 91109 (United States)

    2017-04-01

    High-dispersion coronagraphy (HDC) optimally combines high-contrast imaging techniques such as adaptive optics/wavefront control plus coronagraphy to high spectral resolution spectroscopy. HDC is a critical pathway toward fully characterizing exoplanet atmospheres across a broad range of masses from giant gaseous planets down to Earth-like planets. In addition to determining the molecular composition of exoplanet atmospheres, HDC also enables Doppler mapping of atmosphere inhomogeneities (temperature, clouds, wind), as well as precise measurements of exoplanet rotational velocities. Here, we demonstrate an innovative concept for injecting the directly imaged planet light into a single-mode fiber, linking a high-contrast adaptively corrected coronagraph to a high-resolution spectrograph (diffraction-limited or not). Our laboratory demonstration includes three key milestones: close-to-theoretical injection efficiency, accurate pointing and tracking, and on-fiber coherent modulation and speckle nulling of spurious starlight signal coupling into the fiber. Using the extreme modal selectivity of single-mode fibers, we also demonstrated speckle suppression gains that outperform conventional image-based speckle nulling by at least two orders of magnitude.

  1. Impact of physical properties of biodiesel on the injection process in a common-rail direct injection system

    International Nuclear Information System (INIS)

    Boudy, Frederic; Seers, Patrice

    2009-01-01

    This paper presents the influence of biodiesel fuel properties on the injection mass flow rate of a diesel common-rail injection system. Simulations are first performed with ISO 4113 diesel fuel on a four-cylinder common-rail system to evaluate a single and triple injection strategies. For each injection strategy, the impact of modifying a single fuel property at a time is evaluated so as to quantify its influence on the injection process. The results show that fuel density is the main property that affects the injection process, such as total mass injected and pressure wave in the common-rail system. The fuel's viscosity and bulk modulus also influence, but to a lessen degree, the mass flow rate of the injector notably during multiple injection strategies as individual properties change the fuel's dampening property and friction coefficient.

  2. Single-dose Intramuscular-injection Toxicology Test of Water-soluble Carthami-flos and Cervi cornu parvum Pharmacopuncture in a Rat Model

    Directory of Open Access Journals (Sweden)

    Sunju Park

    2015-09-01

    Full Text Available Objectives: The aim of the study is to investigate both the single-dose intramuscular injection toxicity and the approximate lethal dose of water-soluble Carthami-flos and Cervi cornu parvum pharmacopuncture (WCFC in male and female Sprague-Dawley (SD rats. Methods: The study was conducted at Biotoxtech Co. according to the Good Laboratory Practice (GLP regulation and the toxicity test guidelines of the Ministry of Food and Drug Safety (MFDS after approval of the Institutional Animal Care and Use Committee. Dosages for the control, high dose, middle dose and low dose groups were 0.5 mL/animal of saline and 0.5, 0.25 and 0.125 mL/animal of WCFC, respectively. WCFC was injected into the muscle of the left femoral region by using a disposable syringe (1 mL, 26 gauge. The general symptoms and mortality were observed 30 minutes, 1, 2, 4, and 6 hours after the first injection and then daily for 14 days after the injection. The body weights of the SD rats were measured on the day of the injection (before injection and on the third, seventh, and fourteenth days after the injection. Serum biochemical and hematologic tests, necropsy examinations, and histopathologic examinations at the injection site were performed after the observation period. Results: No deaths, abnormal clinical symptoms, or significant weight changes were observed in either male or female SD rats in the control or the test (0.125, 0.25, and 0.5 mL/animal groups during the observation period. No significant differences in hematology and serum biochemistry and no macroscopic abnormalities at necropsy were found. No abnormal reactions at injection sites were noted on the topical tolerance tests. Conclusion: The results of this single-dose toxicity study show that WCFC is safe, its lethal doses in male and female SD rats being estimated to be higher than 0.5 mL/animal.

  3. Effect of single and repeated injections of selective D2-antagonist clebopride on maternal behavior of albino rats.

    Science.gov (United States)

    Tanaeva, K K; Dobryakova, Yu V; Dubynin, V A; Kamensky, A A

    2012-06-01

    This study examined the effect of clebopride at low concentration that did not modify the motor activity on the parental care in female albino rats. Single injection of the drug attenuated the parental care reactions on postinjection minute 20, but not one day thereafter. The daily injection of the drug during the post partum period (1-6 days) resulted in significantly more pronounced and stable effects. The data obtained substantiated the views on the major contribution of D(2)-receptors in the development of behavioral manifestations of puerperal depression.

  4. Efficacy of Liposomal Amphotericin B and Posaconazole in Intratracheal Models of Murine Mucormycosis

    Science.gov (United States)

    Luo, Guanpingsheng; Gebremariam, Teclegiorgis; Lee, Hongkyu; French, Samuel W.; Wiederhold, Nathan P.; Patterson, Thomas F.; Filler, Scott G.

    2013-01-01

    Mucormycosis is a life-threatening fungal infection almost uniformly affecting diabetics in ketoacidosis or other forms of acidosis and/or immunocompromised patients. Inhalation of Mucorales spores provides the most common natural route of entry into the host. In this study, we developed an intratracheal instillation model of pulmonary mucormycosis that hematogenously disseminates into other organs using diabetic ketoacidotic (DKA) or cyclophosphamide-cortisone acetate-treated mice. Various degrees of lethality were achieved for the DKA or cyclophosphamide-cortisone acetate-treated mice when infected with different clinical isolates of Mucorales. In both DKA and cyclophosphamide-cortisone acetate models, liposomal amphotericin B (LAmB) or posaconazole (POS) treatments were effective in improving survival, reducing lungs and brain fungal burdens, and histologically resolving the infection compared with placebo. These models can be used to study mechanisms of infection, develop immunotherapeutic strategies, and evaluate drug efficacies against life-threatening Mucorales infections. PMID:23650163

  5. Numerical Simulations of Two-Phase Reacting Flow in a Single-Element Lean Direct Injection (LDI) Combustor Using NCC

    Science.gov (United States)

    Liu, Nan-Suey; Shih, Tsan-Hsing; Wey, C. Thomas

    2011-01-01

    A series of numerical simulations of Jet-A spray reacting flow in a single-element lean direct injection (LDI) combustor have been conducted by using the National Combustion Code (NCC). The simulations have been carried out using the time filtered Navier-Stokes (TFNS) approach ranging from the steady Reynolds-averaged Navier-Stokes (RANS), unsteady RANS (URANS), to the dynamic flow structure simulation (DFS). The sub-grid model employed for turbulent mixing and combustion includes the well-mixed model, the linear eddy mixing (LEM) model, and the filtered mass density function (FDF/PDF) model. The starting condition of the injected liquid spray is specified via empirical droplet size correlation, and a five-species single-step global reduced mechanism is employed for fuel chemistry. All the calculations use the same grid whose resolution is of the RANS type. Comparisons of results from various models are presented.

  6. Effects of hypertonic dextrose injections in the rabbit carpal tunnel.

    Science.gov (United States)

    Yoshii, Yuichi; Zhao, Chunfeng; Schmelzer, James D; Low, Phillip A; An, Kai-Nan; Amadio, Peter C

    2011-07-01

    This study investigated the effects of different doses of hypertonic dextrose injection on the carpal tunnel subsynovial connective tissue (SSCT) and median nerve in a rabbit model. Thirty-eight New Zealand white rabbits weighing 4.0-4.5 kg were used. One forepaw carpal tunnel was randomly injected with one of five different treatments: saline-single injection; saline-two injections 1 week apart; 10% dextrose-single injection; 20% dextrose-single injection; or 10% dextrose-two injections 1 week apart. Animals were sacrificed at 12 weeks after the initial injection and were evaluated by electrophysiology (EP), SSCT mechanical testing and histology. There were significant increases in the energy absorption of the SSCT in the 10% dextrose-double injection group compared to the saline injection groups. SSCT stiffness was also significantly increased in the 10% dextrose-double injection group compared to the other groups. There was a significant increase in the thickness of the SSCT in the 10% dextrose-double injection group compared to the saline-single injection group and a significant decrease in the nerve short-long diameter ratio in the 10% dextrose-double injection group compared to the saline-single injection group. There were no changes in EP among the groups. SSCT fibrosis is present for up to 12 weeks after dextrose injection; multiple injections have bigger effects, including what appears to be a secondary change in nerve flattening. This model may be useful to study the effects of external fibrosis on nerve morphology and physiology, such as occurs clinically in carpal tunnel syndrome. Copyright © 2011 Orthopaedic Research Society.

  7. Diesel Combustion and Emission Using High Boost and High Injection Pressure in a Single Cylinder Engine

    Science.gov (United States)

    Aoyagi, Yuzo; Kunishima, Eiji; Asaumi, Yasuo; Aihara, Yoshiaki; Odaka, Matsuo; Goto, Yuichi

    Heavy-duty diesel engines have adopted numerous technologies for clean emissions and low fuel consumption. Some are direct fuel injection combined with high injection pressure and adequate in-cylinder air motion, turbo-intercooler systems, and strong steel pistons. Using these technologies, diesel engines have achieved an extremely low CO2 emission as a prime mover. However, heavy-duty diesel engines with even lower NOx and PM emission levels are anticipated. This study achieved high-boost and lean diesel combustion using a single cylinder engine that provides good engine performance and clean exhaust emission. The experiment was done under conditions of intake air quantity up to five times that of a naturally aspirated (NA) engine and 200MPa injection pressure. The adopted pressure booster is an external supercharger that can control intake air temperature. In this engine, the maximum cylinder pressure was increased and new technologies were adopted, including a monotherm piston for endurance of Pmax =30MPa. Moreover, every engine part is newly designed. As the boost pressure increases, the rate of heat release resembles the injection rate and becomes sharper. The combustion and brake thermal efficiency are improved. This high boost and lean diesel combustion creates little smoke; ISCO and ISTHC without the ISNOx increase. It also yields good thermal efficiency.

  8. The 15N-leucine single-injection method allows for determining endogenous losses and true digestibility of amino acids in cecectomized roosters.

    Directory of Open Access Journals (Sweden)

    Rujiu Hu

    Full Text Available This study was conducted to assess the influence of dietary protein content in poultry when using the 15N-leucine single-injection method to determine endogenous amino acid losses (EAALs in poultry. Forty-eight cecectomized roosters (2.39 ± 0.23 kg were randomly allocated to eight dietary treatments containing protein levels of 0, 3%, 6%, 9%, 12%, 15%, 18% and 21%. Each bird was precisely fed an experimental diet of 25 g/kg of body weight. After feeding, all roosters were subcutaneously injected with a 15N-leucine solution at a dose of 20 mg/kg of body weight. Blood was sampled 23 h after the injection, and excreta samples were continuously collected during the course of the 48-h experiment. The ratio of 15N-enrichment of leucine in crude mucin to free leucine in plasma ranged from 0.664 to 0.763 and remained relatively consistent (P > 0.05 across all treatments. The amino acid (AA profiles of total endogenous AAs, except isoleucine, alanine, aspartic acid, cysteine, proline and serine, were not influenced (P > 0.05 by dietary protein contents. The predominant endogenous AAs in the excreta were glutamic acid, aspartic acid, threonine, serine and proline. The order of the relative proportions of these predominant AAs also remained relatively constant (P > 0.05. The endogenous losses of total AAs determined with the 15N-leucine single-injection method increased curvilinearly with the dietary protein contents. The true digestibility of most AAs and total AAs was independent of their respective dietary protein levels. Collectively, the 15N-leucine single-injection method is appropriate for determining EAALs and the true digestibility of AAs in poultry fed varying levels of protein-containing ingredients.

  9. Effects of intratracheally instilled laser printer-emitted engineered nanoparticles in a mouse model: A case study of toxicological implications from nanomaterials released during consumer use.

    Science.gov (United States)

    Pirela, Sandra V; Lu, Xiaoyan; Miousse, Isabelle; Sisler, Jennifer D; Qian, Yong; Guo, Nancy; Koturbash, Igor; Castranova, Vincent; Thomas, Treye; Godleski, John; Demokritou, Philip

    2016-01-01

    Incorporation of engineered nanomaterials (ENMs) into toners used in laser printers has led to countless quality and performance improvements. However, the release of ENMs during printing (consumer use) has raised concerns about their potential adverse health effects. The aim of this study was to use "real world" printer-emitted particles (PEPs), rather than raw toner powder, and assess the pulmonary responses following exposure by intratracheal instillation. Nine-week old male Balb/c mice were exposed to various doses of PEPs (0.5, 2.5 and 5 mg/kg body weight) by intratracheal instillation. These exposure doses are comparable to real world human inhalation exposures ranging from 13.7 to 141.9 h of printing. Toxicological parameters reflecting distinct mechanisms of action were evaluated, including lung membrane integrity, inflammation and regulation of DNA methylation patterns. Results from this in vivo toxicological analysis showed that while intratracheal instillation of PEPs caused no changes in the lung membrane integrity, there was a pulmonary immune response, indicated by an elevation in neutrophil and macrophage percentage over the vehicle control and low dose PEPs groups. Additionally, exposure to PEPs upregulated expression of the Ccl5 ( Rantes ), Nos1 and Ucp2 genes in the murine lung tissue and modified components of the DNA methylation machinery ( Dnmt3a ) and expression of transposable element (TE) LINE-1 compared to the control group. These genes are involved in both the repair process from oxidative damage and the initiation of immune responses to foreign pathogens. The results are in agreement with findings from previous in vitro cellular studies and suggest that PEPs may cause immune responses in addition to modifications in gene expression in the murine lung at doses that can be comparable to real world exposure scenarios, thereby raising concerns of deleterious health effects.

  10. Basal cardiomyopathy develops in rabbits with ventricular tachyarrhythmias induced by a single injection of adrenaline.

    Science.gov (United States)

    Ashida, Terunao; Takato, Tetsuya; Matsuzaki, Gen; Seko, Yoshinori; Fujii, Jun; Kawai, Sachio

    2014-01-01

    We have recently demonstrated that basal cardiomyopathy develops in rabbits with ventricular tachyarrhythmias that have been induced by electrical stimulation of the cervical vagus. This study investigated whether similar basal cardiomyopathy would develop in rabbits with ventricular tachyarrhythmias induced by a single injection of adrenaline. Adrenaline was intravenously infused for 10-360 seconds in anesthetized rabbits. Colloidal carbon was injected after adrenaline infusion. Wall movement velocity of the left ventricular base was assessed by tissue Doppler echocardiography. Animals were killed either 1 week or 3-4 weeks later. Pathological lesions were identified by deposits of carbon particles. Animals were divided into two groups according to the infused dose of adrenaline. The small-dose group (group S, n = 15) received 1-10 μg and the large-dose group (group L, n = 23) received 15-60 μg of adrenaline. Adrenaline infusion induced premature ventricular contractions followed by monomorphic ventricular tachycardias in 22 of 23 animals in group L, but in only 1 of 15 animals in group S. Wall movement velocity of the left ventricular base decreased just after adrenaline infusion, remained low after 1 week, and recovered to near-baseline levels after 3-4 weeks in group L. Unique cardiac lesions identified by deposits of carbon particles were frequently observed on the left ventricular basal portion, almost always associated with the mitral valve and papillary muscles, but were never observed in the apical area. Lesions involving all areas of the left ventricular basal portion were observed in 22 of 23 animals in group L, but in only 2 of 15 animals in group S. Basal cardiomyopathy developed in rabbits with ventricular tachycardias induced by a single injection of adrenaline.

  11. Rapid induction of dopamine sensitization in the nucleus accumbens shell induced by a single injection of cocaine.

    Science.gov (United States)

    Singer, Bryan F; Bryan, Myranda A; Popov, Pavlo; Robinson, Terry E; Aragona, Brandon J

    2017-05-01

    Repeated intermittent exposure to cocaine results in the neurochemical sensitization of dopamine (DA) transmission within the nucleus accumbens (NAc). Indeed, the excitability of DA neurons in the ventral tegmental area (VTA) is enhanced within hours of initial psychostimulant exposure. However, it is not known if this is accompanied by a comparably rapid change in the ability of cocaine to increase extracellular DA concentrations in the ventral striatum. To address this question we used fast-scan cyclic voltammetry (FSCV) in awake-behaving rats to measure DA responses in the NAc shell following an initial intravenous cocaine injection, and then again 2-h later. Both injections quickly elevated DA levels in the NAc shell, but the second cocaine infusion produced a greater effect than the first, indicating sensitization. This suggests that a single injection of cocaine induces sensitization-related plasticity very rapidly within the mesolimbic DA system. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. 3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent

    International Nuclear Information System (INIS)

    Fink, Christian; Ley, Sebastian; Puderbach, Michael; Plathow, Christian; Kauczor, Hans-Ulrich; Bock, Michael

    2004-01-01

    The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 ; voxel size: 1.3 x 2.5 x 4.0 mm 3 ; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 ; voxel size: 0.8 x 1.0 x 1.6 mm 3 ) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21±8 vs. 13±3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer. (orig.)

  13. An experimental study of fuel injection strategies in CAI gasoline engine

    Energy Technology Data Exchange (ETDEWEB)

    Hunicz, J.; Kordos, P. [Department of Combustion Engines and Transport, Lublin University of Technology, Nadbystrzycka 36, 20-618 Lublin (Poland)

    2011-01-15

    Combustion of gasoline in a direct injection controlled auto-ignition (CAI) single-cylinder research engine was studied. CAI operation was achieved with the use of the negative valve overlap (NVO) technique and internal exhaust gas re-circulation (EGR). Experiments were performed at single injection and split injection, where some amount of fuel was injected close to top dead centre (TDC) during NVO interval, and the second injection was applied with variable timing. Additionally, combustion at variable fuel-rail pressure was examined. Investigation showed that at fuel injection into recompressed exhaust fuel reforming took place. This process was identified via an analysis of the exhaust-fuel mixture composition after NVO interval. It was found that at single fuel injection in NVO phase, its advance determined the heat release rate and auto-ignition timing, and had a strong influence on NO{sub X} emission. However, a delay of single injection to intake stroke resulted in deterioration of cycle-to-cycle variability. Application of split injection showed benefits of this strategy versus single injection. Examinations of different fuel mass split ratios and variable second injection timing resulted in further optimisation of mixture formation. At equal share of the fuel mass injected in the first injection during NVO and in the second injection at the beginning of compression, the lowest emission level and cyclic variability improvement were observed. (author)

  14. Effect of injection pressure on performance, emission, and combustion characteristics of diesel-acetylene-fuelled single cylinder stationary CI engine.

    Science.gov (United States)

    Srivastava, Anmesh Kumar; Soni, Shyam Lal; Sharma, Dilip; Jain, Narayan Lal

    2018-03-01

    In this paper, the effect of injection pressure on the performance, emission, and combustion characteristics of a diesel-acetylene fuelled single cylinder, four-stroke, direct injection (DI) diesel engine with a rated power of 3.5 kW at a rated speed of 1500 rpm was studied. Experiments were performed in dual-fuel mode at four different injection pressures of 180, 190, 200, and 210 bar with a flow rate of 120 LPH of acetylene and results were compared with that of baseline diesel operation. Experimental results showed that highest brake thermal efficiency of 27.57% was achieved at injection pressure of 200 bar for diesel-acetylene dual-fuel mode which was much higher than 23.32% obtained for baseline diesel. Carbon monoxide, hydrocarbon, and smoke emissions were also measured and found to be lower, while the NO x emissions were higher at 200 bar in dual fuel mode as compared to those in other injection pressures in dual fuel mode and also for baseline diesel mode. Peak cylinder pressure, net heat release rate, and rate of pressure rise were also calculated and were higher at 200 bar injection pressure in dual fuel mode.

  15. Single injection techniques in determining age-related changes in porcine renal function

    International Nuclear Information System (INIS)

    Robbins, M.E.C.

    1984-01-01

    Glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) were determined in 32 anaesthetised female Large White pigs, aged 4-24 months, from the plasma disappearance curves of [sup(99m)Tc]DTPA and [ 131 I]hippuran respectively. Clearance was also monitored by external counting over the heart. GFR and ERPF increased markedly with age in pigs up to 12 months old, reaching mean values of 242.06 +- 5.89 and 919.39 +- 79.01 mL/min. In pigs aged 12-24 months ERPF increased slightly but renal function remained essentially unchanged after 1 yr of age. These results for renal function were similar to previous estimates, using continuous infusion techniques inferring that GFR and ERPF could be accurately monitored using single injection procedures. (author)

  16. Electrically injected GaAsBi/GaAs single quantum well laser diodes

    Directory of Open Access Journals (Sweden)

    Juanjuan Liu

    2017-11-01

    Full Text Available We present electrically injected GaAs/GaAsBi single quantum well laser diodes (LDs emitting at a record long wavelength of 1141 nm at room temperature grown by molecular beam epitaxy. The LDs have excellent device performances with internal quantum efficiency of 86%, internal loss of 10 cm-1 and transparency current density of 196 A/cm2. The LDs can operate under continuous-wave mode up to 273 K. The characteristic temperature are extracted to be 125 K in the temperature range of 77∼150 K, and reduced to 90 K in the range of 150∼273 K. The temperature coefficient of 0.3 nm/K is extracted in the temperature range of 77∼273 K.

  17. Safety and effectiveness of a single and repeat intramuscular injection of a GnRH vaccine (GonaCon™) in adult female domestic cats.

    Science.gov (United States)

    Vansandt, L M; Kutzler, M A; Fischer, A E; Morris, K N; Swanson, W F

    2017-04-01

    Sterilization is a key strategy to reduce the number of domestic cats entering and killed in shelters each year. However, surgical sterilization is expensive and labour-intensive and cannot fully address the 70 million free-roaming cats estimated to exist in the United States. GonaCon™ is a gonadotropin-releasing hormone vaccine originally developed for use as a wildlife immunocontraceptive. An earlier formulation was tested in domestic cats and found to be safe and effective for long-term contraception. However, the current Environmental Protection Agency (EPA)-registered formulation consists of a different antigen-carrier protein and increased antigen concentration and has never been tested in cats. A pilot study was undertaken to evaluate the short-term safety of a single GonaCon immunization, assess the consequences of vaccinated cats receiving an accidental second GonaCon injection and determine the humoral immune response to immunization. During Phase 1, cats in Group A (n = 3) received a single intramuscular injection of GonaCon and Group B (n = 3) received a single intramuscular injection of saline. During Phase 2, Group A received a second GonaCon injection and Group B received their initial GonaCon injection. All cats developed GnRH antibodies within 30 days of vaccine administration. The endpoint titre (1:1,024,000) was similar among all cats, and levels remained high throughout the duration of the study. Four cats developed a sterile, painless, self-limiting mass at the site of injection. The mean number of days to mass development was 110.3 (range, 18-249 days). In conclusion, this preliminary study suggests that the EPA-registered GonaCon formulation is safe for continued testing in domestic cats, an accidental revaccination should not increase the risk of a vaccine reaction and the EPA-registered formulation effectively elicits a strong humoral immune response. © 2016 Blackwell Verlag GmbH.

  18. Endoscopic treatment of vesicoureteral reflux in children with subureteral dextranomer/hyaluronic acid injection: a single-centre, 7-year experience

    Science.gov (United States)

    Biočíc, Mihovil; Todoríc, Jakov; Budimir, Dražen; Roíc, Andrea Cvitkovíc; Pogorelíc, Zenon; Juríc, Ivo; Šušnjar, Tomislav

    2012-01-01

    Background The goals of medical intervention in patients with vesicoureteral reflux are to allow normal renal growth, prevent infections and pyelonephritis, and prevent renal failure. We present our experience with endoscopic treatment of vesicoureteral reflux in children by subureteral dextranomer/hyaluronic acid copolymer injection. Methods Under cystoscopic guidance, dextranomer/hyaluronic acid copolymer underneath the intravesical portion of the ureter in a subureteral or submucosal location was injected in patients undergoing endoscopic correction of vesicoureteral reflux. Results A total of 282 patients (120 boys and 162 girls) underwent the procedure. There were 396 refluxed ureters altogether. The mean age of patients was 4.9 years. The mean overall follow-up period was 44 months. Among the 396 ureters treated, 76% were cured with a single injection. A second and third injection raised the cure rate to 93% and 94%, respectively. Twenty-two (6%) ureters failed all 3 injections, and were converted to open surgery. Conclusion Endoscopic treatment of vesicoureteral reflux can be recommended as a first-line therapy for most cases of vesicoureteral reflux, because of the short hospital stay, absence of complications and the high success rate. PMID:22854114

  19. Induction of biotransformation enzymes by the carcinogenic air-pollutant 3-nitrobenzanthrone in liver, kidney and lung, after intra-tracheal instillation in rats.

    Science.gov (United States)

    Mizerovská, Jana; Dračínská, Helena; Frei, Eva; Schmeiser, Heinz H; Arlt, Volker M; Stiborová, Marie

    2011-02-28

    3-Nitrobenzanthrone (3-NBA), a carcinogenic air pollutant, was investigated for its ability to induce cytochrome P450 (CYP) 1A1/2 and NAD(P)H:quinone oxidoreductase (NQO1) in liver, kidney and lung of rats treated by intra-tracheal instillation. The organs used were from a previous study performed to determine the persistence of 3-NBA-derived DNA adducts in target and non-target tissues (Bieler et al., Carcinogenesis 28 (2007) 1117-1121, [22]). NQO1 is the enzyme reducing 3-NBA to N-hydroxy-3-aminobenzanthrone (N-OH-3-ABA) and CYP1A enzymes oxidize a human metabolite of 3-NBA, 3-aminobenzanthrone (3-ABA), to yield the same reactive intermediate. 3-NBA and 3-ABA are both activated to species forming DNA adducts by cytosols and/or microsomes isolated from rat lung, the target organ for 3-NBA carcinogenicity, and from liver and kidney. Each compound generated the same five DNA adducts detectable by (32)P-postlabelling. When hepatic cytosols from rats treated with 0.2 or 2mg/kg body weight of 3-NBA were incubated with 3-NBA, DNA adduct formation was 3.2- and 8.6-fold higher, respectively, than in incubations with cytosols from control animals. Likewise, cytosols isolated from lungs and kidneys of rats exposed to 3-NBA more efficiently activated 3-NBA than those of control rats. This increase corresponded to an increase in protein levels and enzymatic activities of NQO1. Incubations of hepatic, pulmonary or renal microsomes of 3-NBA-treated rats with 3-ABA led to an 9.6-fold increase in DNA-adduct formation relative to controls. The highest induction in DNA-adduct levels was found in lung. The stimulation of DNA-adduct formation correlated with expression of CYP1A1/2 induced by the intra-tracheal instillation of 3-NBA. The results demonstrate that 3-NBA induces NQO1 and CYP1A1/2 in livers, lungs and kidneys of rats after intra-tracheal instillation, thereby enhancing its own genotoxic and carcinogenic potential. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Development and validation of double and single Wiebe function for multi-injection mode Diesel engine combustion modelling for hardware-in-the-loop applications

    International Nuclear Information System (INIS)

    Maroteaux, Fadila; Saad, Charbel; Aubertin, Fabrice

    2015-01-01

    Highlights: • Modelling of Diesel engine combustion with multi-injection mode was conducted. • Double and single Wiebe correlations for pilot, main and post combustion processes were calibrated. • Ignition delay time correlations have been developed and calibrated using experimental data for each injection. • The complete in-cylinder model has been applied successfully to real time simulations on HiL test bed. - Abstract: The improvement of Diesel engine performances in terms of fuel consumption and pollutant emissions has a huge impact on management system and diagnostic procedure. Validation and testing of engine performances can benefit from the use of theoretical models, for the reduction of development time and costs. Hardware in the Loop (HiL) test bench is a suitable way to achieve these objectives. However, the increasing complexity of management systems rises challenges for the development of very reduced physical models able to run in real time applications. This paper presents an extension of a previously developed phenomenological Diesel combustion model suitable for real time applications on a HiL test bench. In the earlier study, the modelling efforts have been targeted at high engine speeds with a very short computational time window, and where the engine operates with single injection. In the present work, a modelling of in-cylinder processes at low and medium engine speeds with multi-injection is performed. In order to reach an adequate computational time, the combustion progress during the pilot and main injection periods has been treated through a double Wiebe function, while the post combustion period has required a single Wiebe function. This paper describes the basic system models and their calibration and validation against experimental data. The use of the developed correlations of Wiebe coefficients and ignition delay times for each combustion phase, included in the in-cylinder crank angle global model, is applied for the prediction

  1. Modelling of profile control with LH wave injection in the HL-2A single-null divertor plasma

    International Nuclear Information System (INIS)

    Gao Qingdi; Yuan Baoshan; Li Fangzhu; Wang, Aike; Budny, R.V.

    2005-01-01

    In the HL-2A tokamak a single-null divertor configuration has been established. The separatrix of the single-null diverted plasma was identified with a filament model, and the determined striking area on the target plate is in agreement with the measurements of electric probe array. Higher power LH wave (1.5MW) is injected to the diverted plasma with a nearly symmetric spectrum. Dominant electron heating and current profile control are investigated with numerical simulation. Plasma heating by electron Landau interaction results in operation scenarios of preferentially dominant electron heating. Due to the off-axis driven current, an optimized q-profile is formed, and an enhanced confinement regime with steep electron temperature gradient is produced. The clear decrease of the electron thermal conductivity in the LH power deposition region shows that an electron-ITB is developed. When higher LH power injects into the target plasma that is heated by NBI (0.5MW), the ion temperature has a large increment in addition to the high increase of electron temperature. The temperature profiles indicate that an enhanced core confinement is established with both ion-ITB and electron-ITB developed. (author)

  2. Forecast of thermal-hydrological conditions and air injection test results of the single heater test at Yucca Mountain

    International Nuclear Information System (INIS)

    Birkholzer, J.T.; Tsang, Y.W.

    1996-12-01

    The heater in the Single Heater Test (SHT) in alcove 5 of the Exploratory Studies Facility (ESF) was turned on August 26, 1996. A large number of sensors are installed in the various instrumented boreholes to monitor the coupled thermal-hydrological-mechanical-chemical responses of the rock mass to the heat generated in the single heater. In this report the authors present the results of the modeling of both the heating and cooling phases of the Single Heater Test (SHT), with focus on the thermal-hydrological aspect of the coupled processes. Also in this report, the authors present simulations of air injection tests will be performed at different stages of the heating and cooling phase of the SHT

  3. Anesthetic efficacy of a repeated intraosseous injection following a primary intraosseous injection.

    Science.gov (United States)

    Jensen, Joanne; Nusstein, John; Drum, Melissa; Reader, Al; Beck, Mike

    2008-02-01

    The purpose of this prospective, randomized, single-blinded study was to determine the anesthetic efficacy of a repeated intraosseous injection given 30 minutes after a primary intraosseous injection. Using a crossover design, 55 subjects randomly received a primary X-tip intraosseous injection (Dentsply Inc, York, PA) of 1.4 mL of 2% lidocaine with epinephrine (using the Wand; Milestone Scientific, Deerfield, IL) and a repeated intraosseous or mock injection at 30 minutes in two appointments. The first molar and adjacent teeth were pulp tested every 2 minutes for a total of 120 minutes. Success was defined as obtaining two consecutive 80 readings with the electric pulp tester. Success of the initial intraosseous injection was 100% for the first molar. The repeated intraosseous injection mimicked the initial intraosseous injection in terms of pulpal anesthesia and statistically provided another 15 minutes of pulpal anesthesia. In conclusion, using the methodology presented, repeating the intraosseous injection 30 minutes after an initial intraosseous injection will provide an additional 15 minutes of pulpal anesthesia.

  4. Long-term Dose Stability of OnabotulinumtoxinA Injection for Adductor Spasmodic Dysphonia: A 19-Year Single Institution Experience

    Directory of Open Access Journals (Sweden)

    Paul Paddle

    2017-11-01

    Full Text Available ObjectivesAdductor spasmodic dysphonia (AdSD is a focal dystonia predominantly involving the laryngeal adductor muscles. AdSD is reported to be a largely non-progressive neurological disorder, though fluctuations in symptom severity do occur. Repeated laryngeal onabotulinumtoxinA (BTX-A injections are the primary management for AdSD. A number of studies have demonstrated long-term dose stability as evidence of this long-term disease stability.MethodsA retrospective review was performed on all patients undergoing BTX-A injections for AdSD from April 1994 to September 2013 by a single laryngologist at a tertiary referral laryngology center. Patient demographics, injection doses, use of diazepam and/or lidocaine, and self-reported vocal function were recorded. Multiple linear regression analyses were performed.Results83 patients underwent a total of 1,168 injections over 19 years. The mean starting dose was 2.35 MU (0.79 SD. The mean long-term dose was 2.36 MU (0.79 SD. After adjusting for confounders, the change in the relative dose of BTX-A, with every year elapsed since initial dose was 0.13% (95% confidence interval −0.31 to 0.57%, p = 0.568.ConclusionBTX-A dose is stable over time in our large cohort of patients treated with bilateral thyroarytenoid injections for AdSD.

  5. Detection of extracellular neutrophil elastase in hamster lungs after intratracheal instillation of E. coli lipopolysaccharide using a fluorogenic, elastase-specific, synthetic substrate.

    Science.gov (United States)

    Rudolphus, A.; Stolk, J.; van Twisk, C.; van Noorden, C. J.; Dijkman, J. H.; Kramps, J. A.

    1992-01-01

    Repeated intratracheal instillations of E. coli lipopolysaccharide (LPS) in hamster lungs cause an influx of polymorphonuclear leukocytes (PMNs) into the alveolar walls, with concomitant development of severe emphysema. It has been suggested that elastase, released by these PMNs, is involved in the development of emphysema. This study demonstrates the release of elastase from recruited PMNs in cryostat sections of hamster lungs, after being treated once, twice, or thrice with LPS, intratracheally. Elastase activity was visualized using two elastase-specific synthetic substrates, to which a methoxynaphthylamine (MNA) group had been bound covalently. Liberated MNA, when made insoluble by coupling with 5-nitrosalicylaldehyde, fluoresces strongly. The authors observed that the interval between start of incubation and appearance of fluorescence and the intensity of fluorescence correlated with the number of LPS administrations. Fluorescence was observed to be located in or in close vicinity to alveolar walls. No fluorescence was observed in sections of untreated hamsters. Liberation of MNA from synthetic substrates was delayed strongly by the addition of a recombinant secretory leukocyte proteinase inhibitor or a substituted cephalosporin neutrophil elastase inhibitor. The authors conclude that LPS-mediated PMN influx into the lung is accompanied by release of elastase from these cells and speculate that this PMN-elastase is involved in the development of LPS-mediated emphysema. Images Figure 1 Figure 2 Figure 3 PMID:1632460

  6. Intratracheal administration of fullerene nanoparticles activates splenic CD11b{sup +} cells

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Ning [Department of Immunology and Parasitology, School of Medicine, University of Occupational and Environmental Health, Japan, 1-1 Iseigaoka, Yahata-nishi-ku, Kitakyushu 807-8555 (Japan); Kunugita, Naoki [Department of Environmental Health, National Institute of Public Health, 2-3-6, Minami, Wako 351-0197 (Japan); Ichinose, Takamichi [Department of Health Sciences, Oita University of Nursing and Health Sciences, Oita 870-1201 (Japan); Song, Yuan [Department of Immunology and Parasitology, School of Medicine, University of Occupational and Environmental Health, Japan, 1-1 Iseigaoka, Yahata-nishi-ku, Kitakyushu 807-8555 (Japan); Yokoyama, Mitsuru [Bio-information Research Center, University of Occupational and Environmental Health, Japan, 1-1 Iseigaoka, Yahata-nishi-ku, Kitakyushu 807-8555 (Japan); Arashidani, Keiichi [School of Health Sciences, University of Occupational and Environmental Health, Japan, 1-1 Iseigaoka, Yahata-nishi-ku, Kitakyushu 807-8555 (Japan); Yoshida, Yasuhiro, E-mail: freude@med.uoeh-u.ac.jp [Department of Immunology and Parasitology, School of Medicine, University of Occupational and Environmental Health, Japan, 1-1 Iseigaoka, Yahata-nishi-ku, Kitakyushu 807-8555 (Japan)

    2011-10-30

    Highlights: {yields} Fullerene administration triggered splenic responses. {yields} Splenic responses occurred at different time-points than in the lung tissue. {yields} CD11b{sup +} cells were demonstrated to function as responder cells to fullerene. - Abstract: Fullerene nanoparticles ('Fullerenes'), which are now widely used materials in daily life, have been demonstrated to induce elevated pulmonary inflammation in several animal models; however, the effects of fullerenes on the immune system are not fully understood. In the present study, mice received fullerenes intratracheally and were sacrificed at days 1, 6 and 42. Mice that received fullerenes exhibited increased proliferation of splenocytes and increased splenic production of IL-2 and TNF-{alpha}. Changes in the spleen in response to fullerene treatment occurred at different time-points than in the lung tissue. Furthermore, fullerenes induced CDK2 expression and activated NF-{kappa}B and NFAT in splenocytes at 6 days post-administration. Finally, CD11b{sup +} cells were demonstrated to function as responder cells to fullerene administration in the splenic inflammatory process. Taken together, in addition to the effects on pulmonary responses, fullerenes also modulate the immune system.

  7. Pulmonary Toxicity, Distribution, and Clearance of Intratracheally Instilled Silicon Nanowires in Rats

    Directory of Open Access Journals (Sweden)

    Jenny R. Roberts

    2012-01-01

    Full Text Available Silicon nanowires (Si NWs are being manufactured for use as sensors and transistors for circuit applications. The goal was to assess pulmonary toxicity and fate of Si NW using an in vivo experimental model. Male Sprague-Dawley rats were intratracheally instilled with 10, 25, 50, 100, or 250 μg of Si NW (~20–30 nm diameter; ~2–15 μm length. Lung damage and the pulmonary distribution and clearance of Si NW were assessed at 1, 3, 7, 28, and 91 days after-treatment. Si NW treatment resulted in dose-dependent increases in lung injury and inflammation that resolved over time. At day 91 after treatment with the highest doses, lung collagen was increased. Approximately 70% of deposited Si NW was cleared by 28 days with most of the Si NW localized exclusively in macrophages. In conclusion, Si NW induced transient lung toxicity which may be associated with an early rapid particle clearance; however, persistence of Si NW over time related to dose or wire length may lead to increased collagen deposition in the lung.

  8. Functional ability and fate of pulmonary alveolar macrophages after intratracheal instillation into rats

    International Nuclear Information System (INIS)

    Snipes, M.B.; Feddersen, D.; Mueller, H.L.; Guilmette, R.A.; Haley, P.J.

    1988-01-01

    Pulmonary alveolar macrophages (PAM) from donor rats were intratracheally instilled into recipient rats to determine if donor macrophages were functionally similar to the recipient's own macrophages. Recipient and donor (extrinsic) PAM were equivalent in their ability to phagocytize 1.7 μm and 3.9 μm latex microspheres in vivo and sensitized sheep red blood cells in vitro. Also, the extrinsic PAM appeared functionally equivalent to recipient PAM with respect to ability to translocate into interstitial tissue and migrate to the lung-associated lymph nodes (LALN). The recipient PAN appeared to phagocytize the extrinsic PAM, but the extrinsic PAM did not appear to phagocytize the recipient PAM. This could represent a different degree of physiological coordination of intrinsic and extrinsic PAM activities in the lung. Overall, results indicated that extrinsic PAM can live and function in the lungs of recipient rats, and perform most or all of the functions ascribed to recipient PAM. Results also support the hypothesis that PAM are able to move into the pulmonary interstitium and translocate to the LALM without the involvement of other pulmonary macrophages. (author)

  9. Interface inductive currents and carrier injection in hybrid perovskite single crystals

    Science.gov (United States)

    Kovalenko, Alexander; Pospisil, Jan; Krajcovic, Jozef; Weiter, Martin; Guerrero, Antonio; Garcia-Belmonte, Germà

    2017-10-01

    Interfaces between the absorbing perovskite and transporting layers are gaining attention as the key locus that governs solar cell operation and long term performance. The interplay of ionic and electronic processes, along with the asymmetrical architecture of any solar cell, makes the interpretation of electrical measurements always inconclusive. A strategy to progress in relating electric responses, operating mechanisms, and device architecture relies upon simplifying the probing structure. Macroscopic CH3NH3PbBr3 single crystals with symmetrical contacts are tested by means of long-time current transient and impedance spectroscopy. It is observed that interfaces govern carrier injection to (and extraction from) perovskite layers through an inductive (negative capacitance) mechanism with a response time in the range of ˜ 1 - 100 s under dark conditions and inert atmosphere. Current transient exhibits a slow recovering after the occurrence of an undershoot, signaling a complex carrier dynamics which involves changes in surface state occupancy.

  10. Dramatic changes in muscle contractile and structural properties after 2 botulinum toxin injections.

    Science.gov (United States)

    Minamoto, Viviane B; Suzuki, Kentaro P; Bremner, Shannon N; Lieber, Richard L; Ward, Samuel R

    2015-10-01

    Botulinum toxin is frequently administered serially to maintain therapeutic muscle paralysis, but the effect of repeated doses on muscle function are largely unknown. This study characterized the muscle response to 2 onabotulinum toxin (BoNT) injections separated by 3 months. Animal subjects received a single toxin injection (n = 8), 2 BoNT injections separated by 3 months (n = 14), or 1 BoNT and 1 saline injection separated by 3 months (n = 8). The functional effect of 2 serial injections was exponentially greater than the effect of a single injection. While both groups treated with a single BoNT injection had decreased torque in the injected leg by approximately 50% relative to contralateral legs, the double BoNT injected group had decreased torque by over 95% relative to the preinjection level. Both single and double BoNT injections produced clear signs of fiber-type grouping. These experiments demonstrate a disproportionately greater effect of repeated BoNT injections. © 2015 Wiley Periodicals, Inc.

  11. Reactive Power Injection Strategies for Single-Phase Photovoltaic Systems Considering Grid Requirements

    DEFF Research Database (Denmark)

    Yang, Yongheng; Wang, Huai; Blaabjerg, Frede

    2014-01-01

    .g. Germany and Italy. Those advanced features can be provided by next generation PV systems, and will be enhanced in the future to ensure an even efficient and reliable utilization of PV systems. In light of this, Reactive Power Injection (RPI) strategies for single-phase PV systems are explored...... in this paper. The RPI possibilities are: a) constant average active power control, b) constant active current control, c) constant peak current control and d) thermal optimized control strategy. All those strategies comply with the currently active grid codes, but are with different objectives. The proposed...... RPI strategies are demonstrated firstly by simulations and also tested experimentally on a 1 kW singe-phase grid-connected system in LVRT operation mode. Those results show the effectiveness and feasibilities of the proposed strategies with reactive power control during LVRT operation. The design...

  12. Watt-level widely tunable single-mode emission by injection-locking of a multimode Fabry-Perot quantum cascade laser

    Science.gov (United States)

    Chevalier, Paul; Piccardo, Marco; Anand, Sajant; Mejia, Enrique A.; Wang, Yongrui; Mansuripur, Tobias S.; Xie, Feng; Lascola, Kevin; Belyanin, Alexey; Capasso, Federico

    2018-02-01

    Free-running Fabry-Perot lasers normally operate in a single-mode regime until the pumping current is increased beyond the single-mode instability threshold, above which they evolve into a multimode state. As a result of this instability, the single-mode operation of these lasers is typically constrained to few percents of their output power range, this being an undesired limitation in spectroscopy applications. In order to expand the span of single-mode operation, we use an optical injection seed generated by an external-cavity single-mode laser source to force the Fabry-Perot quantum cascade laser into a single-mode state in the high current range, where it would otherwise operate in a multimode regime. Utilizing this approach, we achieve single-mode emission at room temperature with a tuning range of 36 cm-1 and stable continuous-wave output power exceeding 1 W at 4.5 μm. Far-field measurements show that a single transverse mode is emitted up to the highest optical power, indicating that the beam properties of the seeded Fabry-Perot laser remain unchanged as compared to free-running operation.

  13. [Incidence rate of adverse reaction/event by Qingkailing injection: a Meta-analysis of single rate].

    Science.gov (United States)

    Ai, Chun-ling; Xie, Yan-ming; Li, Ming-quan; Wang, Lian-xin; Liao, Xing

    2015-12-01

    To systematically review the incidence rate of adverse drug reaction/event by Qingkailing injection. Such databases as the PubMed, EMbase, the Cochrane library, CNKI, VIP WanFang data and CBM were searched by computer from foundation to July 30, 2015. Two reviewers independently screened literature according to the inclusion and exclusion criteria, extracted data and cross check data. Then, Meta-analysis was performed by using the R 3.2.0 software, subgroup sensitivity analysis was performed based on age, mode of medicine, observation time and research quality. Sixty-three studies involving 9,793 patients with Qingkailing injection were included, 367 cases of adverse reactions/events were reported in total. The incidence rate of adverse reaction in skin and mucosa group was 2% [95% CI (0.02; 0.03)]; the digestive system adverse reaction was 6% [95% CI(0.05; 0.07); the injection site adverse reaction was 4% [95% CI (0.02; 0.07)]. In the digestive system as the main types of adverse reactions/events, incidence of children and adults were 4.6% [0.021 1; 0.097 7] and 6.9% [0.053 5; 0.089 8], respectively. Adverse reactions to skin and mucous membrane damage as the main performance/event type, the observation time > 7 days and ≤ 7 days incidence of 3% [0.012 9; 0.068 3] and 1.9% [0.007 8; 0.046 1], respectively. Subgroup analysis showed that different types of adverse reactions, combination in the incidence of adverse reactions/events were higher than that of single drug, the difference was statistically significant (P reactions occur, and clinical rational drug use, such as combination, age and other fators, and the influence factors vary in different populations. Therefore, clinical doctors for children and the elderly use special care was required for a clear and open spirit injection, the implementation of individualized medication.

  14. Induction of generalized Shwartzman reaction (GSR) in irradiated rabbits by a single injection of endotoxin

    International Nuclear Information System (INIS)

    Wronowski, T.; Uchanska-Dudzinska, B.; Teisseyre, E.; Kopec, M.

    1976-01-01

    Rabbits were prepared to GSR by either a single dose 30 μg/kg of Salmonella enteritidis endotoxin or by a single whole-body exposure to 850 R of x ray. After 24 hrs provocative dose of endotoxin 50 μg/kg was injected. Histological examinations of kidneys revealed that GSR occurred with equal frequency in both groups of rabbits but was more severe in the animals prepared by irradiation. Protamine gelation test detected soluble fibrin complexes in plasma in about 50% of rabbits 24 hrs after either of the preparatory procedures and virtually in 100% after the provocative endotoxin dose. During the preparatory phase of GSR the irradiation induced a profound decrease in blood lymphocyte count and in the weight of thymus and spleen. It is postulated that early postexposure lysis of lymphatic cells participates in mechanisms leading to thrombotic phenomena after irradiation

  15. Conversion from non-orthogonally to orthogonally polarized optical single-sideband modulation using optically injected semiconductor lasers.

    Science.gov (United States)

    Hung, Yu-Han; Tseng, Chin-Hao; Hwang, Sheng-Kwang

    2018-06-01

    This Letter investigates an optically injected semiconductor laser for conversion from non-orthogonally to orthogonally polarized optical single-sideband modulation. The underlying mechanism relies solely on nonlinear laser characteristics and, thus, only a typical semiconductor laser is required as the key conversion unit. This conversion can be achieved for a broadly tunable frequency range up to at least 65 GHz. After conversion, the microwave phase quality, including linewidth and phase noise, is mostly preserved, and simultaneous microwave amplification up to 23 dB is feasible.

  16. The mechanism of the transient depression of the erythropoietic rate induced in the rat by a single injection of uranyl nitrate

    International Nuclear Information System (INIS)

    Giglio, M.J.; Brandan, N.; Leal, T.L.; Bozzini, C.E.

    1989-01-01

    With the purpose of assessing the effect of uranyl nitrate (UN) on the rate of erythropoiesis, 1 mg/kg of the compound was injected iv to adult female Wistar rats. The dosing vehicle was injected into control animals. A single injection of UN induced a transient depression of the rate of red cell volume 59 Fe uptake, which reached its lowest value (68% depression) by the seventh postinjection day. By 14 days, 59 Fe incorporation had returned to normal. The amount of iron going to erythroid tissue per hour, reticulocyte count, and immunoreactive erythropoietin concentration in both plasma and kidney extracts were also significantly depressed in UN-treated rats in relation to these values in vehicle-injected rats by the seventh postinjection day. Dose-response curves for exogenous erythropoietin (Epo) performed in polycythemic intact and UN-treated rats 7 days after drug injection revealed a significant depression of the response in UN-injected animals. Moreover, bone marrow cells obtained from rats pretreated with UN formed a reduced number of erythroid colonies in vitro in response to Epo. Therefore, possible mechanisms for the observed transient depression in the rate of erythropoiesis associated with acute UN treatment include decreased Epo production and direct or indirect damage of erythroid progenitor cells

  17. Advanced diesel electronic fuel injection and turbocharging

    Science.gov (United States)

    Beck, N. J.; Barkhimer, R. L.; Steinmeyer, D. C.; Kelly, J. E.

    1993-12-01

    The program investigated advanced diesel air charging and fuel injection systems to improve specific power, fuel economy, noise, exhaust emissions, and cold startability. The techniques explored included variable fuel injection rate shaping, variable injection timing, full-authority electronic engine control, turbo-compound cooling, regenerative air circulation as a cold start aid, and variable geometry turbocharging. A Servojet electronic fuel injection system was designed and manufactured for the Cummins VTA-903 engine. A special Servojet twin turbocharger exhaust system was also installed. A series of high speed combustion flame photos was taken using the single cylinder optical engine at Michigan Technological University. Various fuel injection rate shapes and nozzle configurations were evaluated. Single-cylinder bench tests were performed to evaluate regenerative inlet air heating techniques as an aid to cold starting. An exhaust-driven axial cooling air fan was manufactured and tested on the VTA-903 engine.

  18. Intratracheal Administration of Mesenchymal Stem Cells Modulates Tachykinin System, Suppresses Airway Remodeling and Reduces Airway Hyperresponsiveness in an Animal Model.

    Directory of Open Access Journals (Sweden)

    Konrad Urbanek

    Full Text Available The need for new options for chronic lung diseases promotes the research on stem cells for lung repair. Bone marrow-derived mesenchymal stem cells (MSCs can modulate lung inflammation, but the data on cellular processes involved in early airway remodeling and the potential involvement of neuropeptides are scarce.To elucidate the mechanisms by which local administration of MSCs interferes with pathophysiological features of airway hyperresponsiveness in an animal model.GFP-tagged mouse MSCs were intratracheally delivered in the ovalbumin mouse model with subsequent functional tests, the analysis of cytokine levels, neuropeptide expression and histological evaluation of MSCs fate and airway pathology. Additionally, MSCs were exposed to pro-inflammatory factors in vitro.Functional improvement was observed after MSC administration. Although MSCs did not adopt lung cell phenotypes, cell therapy positively affected airway remodeling reducing the hyperplastic phase of the gain in bronchial smooth muscle mass, decreasing the proliferation of epithelium in which mucus metaplasia was also lowered. Decrease of interleukin-4, interleukin-5, interleukin-13 and increase of interleukin-10 in bronchoalveolar lavage was also observed. Exposed to pro-inflammatory cytokines, MSCs upregulated indoleamine 2,3-dioxygenase. Moreover, asthma-related in vivo upregulation of pro-inflammatory neurokinin 1 and neurokinin 2 receptors was counteracted by MSCs that also determined a partial restoration of VIP, a neuropeptide with anti-inflammatory properties.Intratracheally administered MSCs positively modulate airway remodeling, reduce inflammation and improve function, demonstrating their ability to promote tissue homeostasis in the course of experimental allergic asthma. Because of a limited tissue retention, the functional impact of MSCs may be attributed to their immunomodulatory response combined with the interference of neuropeptide system activation and tissue

  19. Induction of phosphatidylcholine biosynthesis via CDPcholine pathway in lung and liver of rats following intratracheal administration of DDT and endosulfan

    International Nuclear Information System (INIS)

    Narayan, S.; Dani, H.M.; Misra, U.K.

    1989-01-01

    The induction of phosphatidylcholine (PC) biosynthesis via the CDPcholine pathway in lung and liver of rats has been shown following the intratracheal administration of 1,1,1-trichloro-2m2-bis(p-chlorophenyl) ethane (DDT) (5 mg/100 g body weight) and endosulfan (1 mg/100 g body weight) for 3 days. Controls received only the vehicle solution (groundnut oil, 0.1 m1/100 g body weight). The treatment of DDT and endosulfan significantly increased the PC contents and the incorporation of radioactive [methyl-3H]choline into PC of lung and liver microsomes. The incorporation of radioactive [methyl-14C]methionine into microsomal PC of lung and liver was not affected significantly by treatment with either of the insecticides. 1,4,5,6,7-hexachloro-5-norbornene-2,3-dimethano cyclic sulfite (endosulfan) administration significantly increased the activity of choline kinase and phosphocholine cytidylyltransferase (both cytosolic and microsomal) of lung, whereas DDT increased the activity of only latter. In liver, both DDT and endosulfan administration significantly increased the activity of choline kinase and phosphocholine cytidylyltransferase (both cytosolic and microsomal). However, the activity of phosphocholinetransferase was not affected in both lung and liver microsomes of rats treated with these insecticides. The PC precursor pool sizes, choline and phosphorylcholine, of lung and liver tissues were not altered by DDT and endosulfan treatments. The present results suggest that the increased level of PC and incorporation of radioactive [methyl-3H]choline into microsomal PC could be the result of increased activity of choline kinase and phosphocholine cytidylyltransferase of lung and liver of rats following intratracheal administration of DDT and endosulfan

  20. Magnetic resonance imaging of single co-labeled mesenchymal stromal cells after intracardial injection in mice

    International Nuclear Information System (INIS)

    Salamon, J.; Adam, G.; Peldschus, K.; Wicklein, D.; Schumacher, U.; Didie, M.; Lange, C.

    2014-01-01

    Purpose: The aim of this study was to establish co-labeling of mesenchymal stromal cells (MSC) for the detection of single MSC in-vivo by MRI and histological validation. Materials and Methods: Mouse MSC were co-labeled with fluorescent iron oxide micro-particles and carboxyfluorescein succinimidyl ester (CFSE). The cellular iron content was determined by atomic absorption spectrometry. Cell proliferation and expression of characteristic surface markers were determined by flow cytometry. The chondrogenic differentiation capacity was assessed. Different amounts of cells (n1 = 5000, n2 = 15 000, n3 = 50 000) were injected into the left heart ventricle of 12 mice. The animals underwent sequential MRI on a clinical 3.0T scanner (Intera, Philips Medical Systems, Best, The Netherlands). For histological validation cryosections were examined by fluorescent microscopy. Results: Magnetic and fluorescent labeling of MSC was established (mean cellular iron content 23.6 ± 3 pg). Flow cytometry showed similar cell proliferation and receptor expression of labeled and unlabeled MSC. Chondrogenic differentiation of labeled MSC was verified. After cell injection MRI revealed multiple signal voids in the brain and fewer signal voids in the kidneys. In the brain, an average of 4.6 ± 1.2 (n1), 9.0 ± 3.6 (n2) and 25.0 ± 1.0 (n3) signal voids were detected per MRI slice. An average of 8.7 ± 3.1 (n1), 22.0 ± 6.1 (n2) and 89.8 ± 6.5 (n3) labeled cells per corresponding stack of adjacent cryosections could be detected in the brain. Statistical correlation of the numbers of MRI signal voids in the brain and single MSC found by histology revealed a correlation coefficient of r = 0.91. Conclusion: The study demonstrates efficient magnetic and fluorescent co-labeling of MSC and their detection on a single cell level in mice by in-vivo MRI and histology. The described techniques may broaden the methods for in-vivo tracking of MSC. (orig.)

  1. A Very Rare Cause of Subglottic Stenosis: Non-Malignant Intratracheal Thyroid Tissue

    Directory of Open Access Journals (Sweden)

    Ümit Aydogmus

    2014-08-01

    Full Text Available We present a case of subglottic stenosis associated with benign thyroid tissue involvement due to relapse of multinodular goiter despite surgery 14 years ago.The patient had undergone bilateral subtotal thyroidectomy 14 years ago and the pathology report had been multinodular thyroid tissue at the time. The patient recently presented to an emergency service due to sudden development of respiratory distress and was then directed to our center. Cervical tomography showed bilateral thyroid tissue that narrowed the tracheal diameter by 80% by invading the trachea from the left wall at the level of the thyroid gland. The patient required urgent tracheostomy due to serious respiratory trouble. The trachea was incised vertically about 2.5 cm below the cricoid cartilage. A 2 cm endotracheal lesion with margins that could not be distinguished from the left vocal cord was observed and biopsies were taken from both this lesion and the tissue surrounding the trachea. A Montgomery T-tube extending from the subglottic area to the distal section was placed. Pathology evaluation revealed histopathological findings that matched normal thyroid tissue. Although infrequent, tracheal invasion associated with a thyroid cancer is known to occur. We present a case with postoperative intratracheal relapse due to a benign cause and the emergency treatment.

  2. Long-term correction of obesity and diabetes in genetically obese mice by a single intramuscular injection of recombinant adeno-associated virus encoding mouse leptin

    Science.gov (United States)

    Murphy, John E.; Zhou, Shangzhen; Giese, Klaus; Williams, Lewis T.; Escobedo, Jaime A.; Dwarki, Varavani J.

    1997-01-01

    The ob/ob mouse is genetically deficient in leptin and exhibits a phenotype that includes obesity and non-insulin-dependent diabetes melitus. This phenotype closely resembles the morbid obesity seen in humans. In this study, we demonstrate that a single intramuscular injection of a recombinant adeno-associated virus (AAV) vector encoding mouse leptin (rAAV-leptin) in ob/ob mice leads to prevention of obesity and diabetes. The treated animals show normalization of metabolic abnormalities including hyperglycemia, insulin resistance, impaired glucose tolerance, and lethargy. The effects of a single injection have lasted through the 6-month course of the study. At all time points measured the circulating levels of leptin in the serum were similar to age-matched control C57 mice. These results demonstrate that maintenance of normal levels of leptin (2–5 ng/ml) in the circulation can prevent both the onset of obesity and associated non-insulin-dependent diabetes. Thus a single injection of a rAAV vector expressing a therapeutic gene can lead to complete and long-term correction of a genetic disorder. Our study demonstrates the long-term correction of a disease caused by a genetic defect and proves the feasibility of using rAAV-based vectors for the treatment of chronic disorders like obesity. PMID:9391128

  3. Baseline performance and emissions data for a single-cylinder, direct-injected diesel engine

    Science.gov (United States)

    Dezelick, R. A.; Mcfadden, J. J.; Ream, L. W.; Barrows, R. F.

    1983-01-01

    Comprehensive fuel consumption, mean effective cylinder pressure, and emission test results for a supercharged, single-cylinder, direct-injected, four-stroke-cycle, diesel test engine are documented. Inlet air-to-exhaust pressure ratios were varied from 1.25 to 3.35 in order to establish the potential effects of turbocharging techniques on engine performance. Inlet air temperatures and pressures were adjusted from 34 to 107 C and from 193 to 414 kPa to determine the effects on engine performance and emissions. Engine output ranged from 300 to 2100 kPa (brake mean effective pressure) in the speed range of 1000 to 3000 rpm. Gaseous and particulate emission rates were measured. Real-time values of engine friction and pumping loop losses were measured independently and compared with motored engine values.

  4. Gene expression analysis in rat lungs after intratracheal exposure to nanoparticles doped with cadmium

    International Nuclear Information System (INIS)

    Coccini, Teresa; Manzo, Luigi; Fabbri, Marco; Sacco, Maria Grazia; Gribaldo, Laura; Roda, Elisa

    2011-01-01

    Silica nanoparticles (NPs) incorporating cadmium (Cd) have been developed for a range of potential application including drug delivery devices. Occupational Cd inhalation has been associated with emphysema, pulmonary fibrosis and lung tumours. Mechanistically, Cd can induce oxidative stress and mediate cell-signalling pathways that are involved in inflammation.This in vivo study aimed at investigating pulmonary molecular effects of NPs doped with Cd (NP-Cd, 1 mg/animal) compared to soluble CdCl 2 (400 μg/animal), in Sprague Dawley rats treated intra-tracheally, 7 and 30 days after administration. NPs of silica containing Cd salt were prepared starting from commercial nano-size silica powder (HiSil T M T700 Degussa) with average pore size of 20 nm and surface area of 240 m 2 /g. Toxicogenomic analysis was performed by the DNA microarray technology (using Agilent Whole Rat Genome Microarray 4x44K) to evaluate changes in gene expression of the entire genome. These findings indicate that the whole genome analysis may represent a valuable approach to assess the whole spectrum of biological responses to cadmium containing nanomaterials.

  5. Gene expression analysis in rat lungs after intratracheal exposure to nanoparticles doped with cadmium

    Science.gov (United States)

    Coccini, Teresa; Fabbri, Marco; Roda, Elisa; Grazia Sacco, Maria; Manzo, Luigi; Gribaldo, Laura

    2011-07-01

    Silica nanoparticles (NPs) incorporating cadmium (Cd) have been developed for a range of potential application including drug delivery devices. Occupational Cd inhalation has been associated with emphysema, pulmonary fibrosis and lung tumours. Mechanistically, Cd can induce oxidative stress and mediate cell-signalling pathways that are involved in inflammation.This in vivo study aimed at investigating pulmonary molecular effects of NPs doped with Cd (NP-Cd, 1 mg/animal) compared to soluble CdCl2 (400 μg/animal), in Sprague Dawley rats treated intra-tracheally, 7 and 30 days after administration. NPs of silica containing Cd salt were prepared starting from commercial nano-size silica powder (HiSil™ T700 Degussa) with average pore size of 20 nm and surface area of 240 m2/g. Toxicogenomic analysis was performed by the DNA microarray technology (using Agilent Whole Rat Genome Microarray 4×44K) to evaluate changes in gene expression of the entire genome. These findings indicate that the whole genome analysis may represent a valuable approach to assess the whole spectrum of biological responses to cadmium containing nanomaterials.

  6. Direct current injection and thermocapillary flow for purification of aligned arrays of single-walled carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Xie, Xu; Islam, Ahmad E.; Seabron, Eric; Dunham, Simon N.; Du, Frank; Lin, Jonathan; Wilson, William L.; Rogers, John A., E-mail: jrogers@illinois.edu [Department of Materials Science and Engineering, Frederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Wahab, Muhammad A.; Alam, Muhammad A. [School of Electrical and Computer Engineering, Purdue University, West Lafayette, Indiana 47907 (United States); Li, Yuhang [Institute of Solid Mechanics, Beihang University, Beijing 100191 (China); Tomic, Bojan [Department of Electrical Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Huang, Jiyuan [Department of Physics, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801 (United States); Burns, Branden [Department of Physics, Purdue University, West Lafayette, Indiana 47907 (United States); Song, Jizhou [Department of Engineering Mechanics and Soft Matter Research Center, Zhejiang University, Hangzhou 310027 (China); Huang, Yonggang [Department of Civil and Environmental Engineering, Department of Mechanical Engineering, Center for Engineering and Health, and Skin Disease Research Center, Northwestern University, Evanston, Illinois 60208 (United States)

    2015-04-07

    Aligned arrays of semiconducting single-walled carbon nanotubes (s-SWNTs) represent ideal configurations for use of this class of material in high performance electronics. Development of means for removing the metallic SWNTs (m-SWNTs) in as-grown arrays represents an essential challenge. Here, we introduce a simple scheme that achieves this type of purification using direct, selective current injection through interdigitated electrodes into the m-SWNTs, to allow their complete removal using processes of thermocapillarity and dry etching. Experiments and numerical simulations establish the fundamental aspects that lead to selectivity in this process, thereby setting design rules for optimization. Single-step purification of arrays that include thousands of SWNTs demonstrates the effectiveness and simplicity of the procedures. The result is a practical route to large-area aligned arrays of purely s-SWNTs with low-cost experimental setups.

  7. Direct current injection and thermocapillary flow for purification of aligned arrays of single-walled carbon nanotubes

    International Nuclear Information System (INIS)

    Xie, Xu; Islam, Ahmad E.; Seabron, Eric; Dunham, Simon N.; Du, Frank; Lin, Jonathan; Wilson, William L.; Rogers, John A.; Wahab, Muhammad A.; Alam, Muhammad A.; Li, Yuhang; Tomic, Bojan; Huang, Jiyuan; Burns, Branden; Song, Jizhou; Huang, Yonggang

    2015-01-01

    Aligned arrays of semiconducting single-walled carbon nanotubes (s-SWNTs) represent ideal configurations for use of this class of material in high performance electronics. Development of means for removing the metallic SWNTs (m-SWNTs) in as-grown arrays represents an essential challenge. Here, we introduce a simple scheme that achieves this type of purification using direct, selective current injection through interdigitated electrodes into the m-SWNTs, to allow their complete removal using processes of thermocapillarity and dry etching. Experiments and numerical simulations establish the fundamental aspects that lead to selectivity in this process, thereby setting design rules for optimization. Single-step purification of arrays that include thousands of SWNTs demonstrates the effectiveness and simplicity of the procedures. The result is a practical route to large-area aligned arrays of purely s-SWNTs with low-cost experimental setups

  8. Analysis of pulsed injection for microgravity receiver tank chilldown

    Science.gov (United States)

    Honkonen, Scott C.; Pietrzyk, Joe R.; Schuster, John R.

    The dominant heat transfer mechanism during the hold phase of a tank chilldown cycle in a low-gravity environment is due to fluid motion persistence following the charge. As compared to the single-charge per vent cycle case, pulsed injection maintains fluid motion and the associated high wall heat transfer coefficients during the hold phase. As a result, the pulsed injection procedure appears to be an attractive method for reducing the time and liquid mass required to chill a tank. However, for the representative conditions considered, no significant benefit can be realized by using pulsed injection as compared to the single-charge case. A numerical model of the charge/hold/vent process was used to evaluate the pulsed injection procedure for tank chilldown in microgravity. Pulsed injection results in higher average wall heat transfer coefficients during the hold, as compared to the single-charge case. However, these high levels were not coincident with the maximum wall-to-fluid temperature differences, as in the single-charge case. For representative conditions investigated, the charge/hold/vent process is very efficient. A slightly shorter chilldown time was realized by increasing the number of pulses.

  9. Prevalence and correlates of neck injection among people who inject drugs in Tijuana, Mexico.

    Science.gov (United States)

    Rafful, Claudia; Wagner, Karla D; Werb, Dan; González-Zúñiga, Patricia E; Verdugo, Silvia; Rangel, Gudelia; Strathdee, Steffanie A

    2015-11-01

    Injecting drugs in the neck has been related to adverse health conditions such as jugular vein thrombosis, deep neck infections, aneurysm, haematomas, airway obstruction, vocal cord paralysis and wound botulism, among others. We identified prevalence and correlates of neck injection among people who inject drugs (PWID) in Tijuana, Mexico. Beginning in 2011, PWID aged ≥18 years who injected drugs within the last month were recruited into a prospective cohort. At baseline and semi-annually, PWID completed interviewer-administered surveys soliciting data on drug-injecting practices. Logistic regression was used to identify predictors of injecting in the neck as the most frequent injection site at a single visit. Of 380 PWID, 35.3% injected in the neck at least once in the past 6 months, among whom 71.6% reported it as their most common injection site, the most common injecting site after the arms (47%). Controlling for age, years injecting and injecting frequency, injecting heroin and methamphetamine two or more times per day and having sought injection assistance were associated with injecting in the neck [adjusted odds ratios (AOR): 2.12; 95% confidence intervals (CI): 1.27-3.53 and AOR: 2.65; 95% CI: 1.52-4.53 respectively]. Injecting in the neck was very common among PWID in Tijuana and was associated with polydrug use and seeking injection assistance. Tailoring harm reduction education interventions for individuals who provide injection assistance ('hit doctors') may allow for the dissemination of safe injecting knowledge to reduce injection-related morbidity and mortality. © 2015 Australasian Professional Society on Alcohol and other Drugs.

  10. Intra-articular injection of hyaluronic acid is not superior to saline solution injection for ankle arthritis: a randomized, double-blind, placebo-controlled study.

    Science.gov (United States)

    DeGroot, Henry; Uzunishvili, Sofia; Weir, Robert; Al-omari, Ali; Gomes, Bruna

    2012-01-04

    Intra-articular injections of hyaluronic acid are potentially useful to treat ankle osteoarthritis, yet their effectiveness has not been proven. Both single and multiple-dose treatments for ankle arthritis with use of various hyaluronic acid products have been recommended, but few high-quality studies have been published. The aim of this study was to compare the effectiveness of a single intra-articular injection of hyaluronic acid with a single intra-articular injection of normal saline solution (placebo) for osteoarthritis of the ankle. Sixty-four patients with ankle osteoarthritis who met all study criteria were randomly assigned to a single intra-articular injection of 2.5 mL of low-molecular-weight, non-cross-linked hyaluronic acid or a single intra-articular injection of 2.5 mL of normal saline solution. The primary outcome measure was the change from baseline in the American Orthopaedic Foot & Ankle Society (AOFAS) clinical rating score at the six-week and twelve-week follow-up examination. Secondary outcome measures included the Ankle Osteoarthritis Scale score and patient-reported pain with use of a visual analog pain scale. Of the sixty-four patients randomized and treated, eight patients withdrew, leaving fifty-six patients who completed the entire study. There was one mild adverse event (1.6%) among the sixty-four patients. At six weeks and twelve weeks, the mean AOFAS scores in the hyaluronic acid group had improved from baseline by 4.9 and 4.9 points, respectively, whereas the mean AOFAS scores in the placebo group initially worsened by 0.4 point at six weeks and then improved by 5.4 points at twelve weeks. While the change at twelve weeks from baseline was substantial for both groups, the between-group differences were not significant. We found that a single intra-articular injection of low-molecular-weight, non-cross-linked hyaluronic acid is not demonstrably superior to a single intra-articular injection of saline solution for the treatment of

  11. Radial oil injection applied to main engine bearings: evaluation of injection control rules

    DEFF Research Database (Denmark)

    Estupiñan, EA; Santos, Ilmar

    2012-01-01

    , the dynamic behaviour of the main bearing of a medium-size engine is theoretically analysed when the engine operates with controllable radial oil injection and four different injection control rules. The theoretical investigation is based on a single-cylinder combustion engine model. The performance......The performance of main bearings in a combustion engine affects key functions such as durability, noise and vibration. Thus, with the aim of reducing friction losses and vibrations between the crankshaft and the bearings, the work reported here evaluates different strategies for applying...... controllable radial oil injection to main crankshaft journal bearings. In an actively lubricated bearing, conventional hydrodynamic lubrication is combined with controllable hydrostatic lubrication, where the oil injection pressures can be modified depending on the operational conditions. In this study...

  12. Pharmacokinetics of cefquinome in red-eared slider turtles (Trachemys scripta elegans) after single intravenous and intramuscular injections.

    Science.gov (United States)

    Uney, K; Altan, F; Cetin, G; Aboubakr, M; Dik, B; Sayın, Z; Er, A; Elmas, M

    2018-02-01

    The purpose of this study was to evaluate the pharmacokinetics of cefquinome (CFQ) following single intravenous (IV) or intramuscular (IM) injections of 2 mg/kg body weight in red-eared slider turtles. Plasma concentrations of CFQ were determined by high-performance liquid chromatography and analyzed using noncompartmental methods. The pharmacokinetic parameters following IV injection were as follows: elimination half-life (t 1/2λz ) 21.73 ± 4.95 hr, volume of distribution at steady-state (V dss ) 0.37 ± 0.11 L/kg, area under the plasma concentration-time curve (AUC 0-∞ ) 163 ± 32 μg hr -1  ml -1 , and total body clearance (Cl T ) 12.66 ± 2.51 ml hr -1  kg -1 . The pharmacokinetic parameters after IM injection were as follows: peak plasma concentration (C max ) 3.94 ± 0.84 μg/ml, time to peak concentration (T max ) 3 hr, t 1/2λz 26.90 ± 4.33 hr, and AUC 0-∞ 145 ± 48 μg hr -1  ml -1 . The bioavailability after IM injection was 88%. Data suggest that CFQ has a favorable pharmacokinetic profile with a long half-life and a high bioavailability in red-eared slider turtles. Further studies are needed to establish a multiple dosage regimen and evaluate clinical efficacy. © 2017 John Wiley & Sons Ltd.

  13. Effect of injection timing and injection pressure on the performance ...

    African Journals Online (AJOL)

    DR OKE

    This paper discusses the feasibility study on the utilization of biodiesel ester of Honge oil (EHO) in common rail direct injection. (CRDI) engine. Biodiesel of EHO has been obtained by transesterification process and characterization has been done. Existing single cylinder diesel engine fitted with conventional mechanical ...

  14. Electroluminescence from single nanowires by tunnel injection: an experimental study

    International Nuclear Information System (INIS)

    Zimmler, Mariano A; Bao Jiming; Shalish, Ilan; Yi, Wei; Yoon, Joonah; Narayanamurti, Venkatesh; Capasso, Federico

    2007-01-01

    We present a hybrid light-emitting diode structure composed of an n-type gallium nitride nanowire on a p-type silicon substrate in which current is injected along the length of the nanowire. The device emits ultraviolet light under both bias polarities. Tunnel injection of holes from the p-type substrate (under forward bias) and from the metal (under reverse bias) through thin native oxide barriers consistently explains the observed electroluminescence behaviour. This work shows that the standard p-n junction model is generally not applicable to this kind of device structure

  15. Single-injection method for evaluation of renal function with 14C-inulin and 3H-tetraethylammonium bromide in dogs and cats

    International Nuclear Information System (INIS)

    Fettman, M.J.; Allen, T.A.; Wilke, W.L.; Radin, M.J.; Eubank, M.C.

    1985-01-01

    A double-isotope single-injection method without urine collection for the estimation of glomerular filtration rate (GFR) and effective renal plasma flow (ERPF) in dogs and cats was evaluated. The GFR was determined, using 14 C-inulin and ERPF was determined, using [ 3 H]tetraethylammonium bromide. Using a modified single exponential, 1-compartment mathematical model, the renal clearance of these solutes was estimated with a plasma radioactivity disappearance curve constructed from samples collected over a 150-minute time period. In 25 dogs, GFR, ERPF, and filtration fraction were 3.55 +/- 0.14 ml/kg/min, 10.51 +/- 0.72 ml/kg/min, and 0.34 +/- 0.02, respectively. In 25 cats, GFR, ERPF, and filtration fraction were 3.24 +/- 0.14 ml/kg/min, 8.14 +/- 0.53 ml/kg/min, and 0.39 +/- 0.02, respectively. This time-efficient and reliable method, using beta-emitting isotopes, yielded renal functional values well within the normal ranges reported by a variety of other isotopic and nonisotopic procedures. The advantages of the present procedure over previous double-isotope single-injection methods include the use of less costly, lower energy-using, and less penetrating beta emittors, as well as a shortened blood sampling schedule

  16. Study of the post-equilibrium slope approximation in the calculation of glomerular filtration rate using the 51Cr-EDTA single injection technique

    International Nuclear Information System (INIS)

    Nimmon, C.C.; McAlister, J.M.; Hickson, B.; Cattell, W.R.

    1975-01-01

    A comparison of methods for calculating the renal clearance of EDTA from the plasma disappearance curve, after a single injection, has been made. Measurements were made on 38 patients, using external monitoring and venous blood sampling techniques, over a period of 24 h after an injection of 100 μCi of 51 Cr-EDTA. The results indicate that the period 3 - 6 h after injection is suitable for sampling the post-equilibrium part of the plasma disappearance curve for values of the glomerular filtration rate (GFR) in the range 0 - 140 ml/min. It was also found that, to within the individual measurement errors, the values of the clearance calculated by using the post-equilibrium period only (PES clearance) can be considered to show a constant proportionality to the values calculated by using the entire plasma disappearance curve (total clearance). (author)

  17. Injection-locked single-mode VCSEL for orthogonal multiplexing and amplitude noise suppression

    DEFF Research Database (Denmark)

    Chipouline, Arkadi; Lyubopytov, Vladimir S.; Malekizandi, Mohammadreza

    2017-01-01

    It has been shown earlier, that the injection locked semiconductor lasers enable effective amplitude noise suppression [1] and makes possible an extra level of signal multiplexing-orthogonal modulation [2], where DPSK and ASK NRZ channels propagate at the same wavelength [3]. In our work we use...... an injection-locked 1550 nm VCSEL as a slave laser providing separation of amplitude and phase modulations, carrying independent information flows. To validate the possibility of phase modulation extraction by an injection-locked VCSEL, an experimental setup shown in Fig. 1 has been built....

  18. Gene expression analysis in rat lungs after intratracheal exposure to nanoparticles doped with cadmium

    Energy Technology Data Exchange (ETDEWEB)

    Coccini, Teresa; Manzo, Luigi [Toxicology Division, Salvatore Maugeri Foundation IRCCS, Pavia (Italy); Fabbri, Marco; Sacco, Maria Grazia; Gribaldo, Laura [European Commission, Joint Research Centre, IHCP- 21027 Ispra (Italy); Roda, Elisa [European Centre for Nanomedicine, University of Pavia, 27100 Pavia (Italy)

    2011-07-06

    Silica nanoparticles (NPs) incorporating cadmium (Cd) have been developed for a range of potential application including drug delivery devices. Occupational Cd inhalation has been associated with emphysema, pulmonary fibrosis and lung tumours. Mechanistically, Cd can induce oxidative stress and mediate cell-signalling pathways that are involved in inflammation.This in vivo study aimed at investigating pulmonary molecular effects of NPs doped with Cd (NP-Cd, 1 mg/animal) compared to soluble CdCl{sub 2} (400 {mu}g/animal), in Sprague Dawley rats treated intra-tracheally, 7 and 30 days after administration. NPs of silica containing Cd salt were prepared starting from commercial nano-size silica powder (HiSil{sup TM} T700 Degussa) with average pore size of 20 nm and surface area of 240 m{sup 2}/g. Toxicogenomic analysis was performed by the DNA microarray technology (using Agilent Whole Rat Genome Microarray 4x44K) to evaluate changes in gene expression of the entire genome. These findings indicate that the whole genome analysis may represent a valuable approach to assess the whole spectrum of biological responses to cadmium containing nanomaterials.

  19. Charge Injection and Transport in Organic Nanofibers

    DEFF Research Database (Denmark)

    Kjelstrup-Hansen, Jakob; Bøggild, Peter; Rubahn, H. G.

    2007-01-01

    the injection barrier height equal to the difference between the metal electrode work function and the HOMO energy level of the organic semiconductor. Semiquantitative modeling suggests that the weak temperature dependence is due to injection into a distribution of states rather than into a single energy level...

  20. Intratracheal IL-6 protects against lung inflammation in direct, but not indirect, causes of acute lung injury in mice.

    Science.gov (United States)

    Bhargava, Rhea; Janssen, William; Altmann, Christopher; Andrés-Hernando, Ana; Okamura, Kayo; Vandivier, R William; Ahuja, Nilesh; Faubel, Sarah

    2013-01-01

    Serum and bronchoalveolar fluid IL-6 are increased in patients with acute respiratory distress syndrome (ARDS) and predict prolonged mechanical ventilation and poor outcomes, although the role of intra-alveolar IL-6 in indirect lung injury is unknown. We investigated the role of endogenous and exogenous intra-alveolar IL-6 in AKI-mediated lung injury (indirect lung injury), intraperitoneal (IP) endotoxin administration (indirect lung injury) and, for comparison, intratracheal (IT) endotoxin administration (direct lung injury) with the hypothesis that IL-6 would exert a pro-inflammatory effect in these causes of acute lung inflammation. Bronchoalveolar cytokines (IL-6, CXCL1, TNF-α, IL-1β, and IL-10), BAL fluid neutrophils, lung inflammation (lung cytokines, MPO activity [a biochemical marker of neutrophil infiltration]), and serum cytokines were determined in adult male C57Bl/6 mice with no intervention or 4 hours after ischemic AKI (22 minutes of renal pedicle clamping), IP endotoxin (10 µg), or IT endotoxin (80 µg) with and without intratracheal (IT) IL-6 (25 ng or 200 ng) treatment. Lung inflammation was similar after AKI, IP endotoxin, and IT endotoxin. BAL fluid IL-6 was markedly increased after IT endotoxin, and not increased after AKI or IP endotoxin. Unexpectedly, IT IL-6 exerted an anti-inflammatory effect in healthy mice characterized by reduced BAL fluid cytokines. IT IL-6 also exerted an anti-inflammatory effect in IT endotoxin characterized by reduced BAL fluid cytokines and lung inflammation; IT IL-6 had no effect on lung inflammation in AKI or IP endotoxin. IL-6 exerts an anti-inflammatory effect in direct lung injury from IT endotoxin, yet has no role in the pathogenesis or treatment of indirect lung injury from AKI or IP endotoxin. Since intra-alveolar inflammation is important in the pathogenesis of direct, but not indirect, causes of lung inflammation, IT anti-inflammatory treatments may have a role in direct, but not indirect, causes of ARDS.

  1. Intratracheal IL-6 protects against lung inflammation in direct, but not indirect, causes of acute lung injury in mice.

    Directory of Open Access Journals (Sweden)

    Rhea Bhargava

    Full Text Available Serum and bronchoalveolar fluid IL-6 are increased in patients with acute respiratory distress syndrome (ARDS and predict prolonged mechanical ventilation and poor outcomes, although the role of intra-alveolar IL-6 in indirect lung injury is unknown. We investigated the role of endogenous and exogenous intra-alveolar IL-6 in AKI-mediated lung injury (indirect lung injury, intraperitoneal (IP endotoxin administration (indirect lung injury and, for comparison, intratracheal (IT endotoxin administration (direct lung injury with the hypothesis that IL-6 would exert a pro-inflammatory effect in these causes of acute lung inflammation.Bronchoalveolar cytokines (IL-6, CXCL1, TNF-α, IL-1β, and IL-10, BAL fluid neutrophils, lung inflammation (lung cytokines, MPO activity [a biochemical marker of neutrophil infiltration], and serum cytokines were determined in adult male C57Bl/6 mice with no intervention or 4 hours after ischemic AKI (22 minutes of renal pedicle clamping, IP endotoxin (10 µg, or IT endotoxin (80 µg with and without intratracheal (IT IL-6 (25 ng or 200 ng treatment.Lung inflammation was similar after AKI, IP endotoxin, and IT endotoxin. BAL fluid IL-6 was markedly increased after IT endotoxin, and not increased after AKI or IP endotoxin. Unexpectedly, IT IL-6 exerted an anti-inflammatory effect in healthy mice characterized by reduced BAL fluid cytokines. IT IL-6 also exerted an anti-inflammatory effect in IT endotoxin characterized by reduced BAL fluid cytokines and lung inflammation; IT IL-6 had no effect on lung inflammation in AKI or IP endotoxin.IL-6 exerts an anti-inflammatory effect in direct lung injury from IT endotoxin, yet has no role in the pathogenesis or treatment of indirect lung injury from AKI or IP endotoxin. Since intra-alveolar inflammation is important in the pathogenesis of direct, but not indirect, causes of lung inflammation, IT anti-inflammatory treatments may have a role in direct, but not indirect, causes of

  2. Single well injection withdrawal tests (SWIW) in fractured rock. Some aspects on interpretation

    International Nuclear Information System (INIS)

    Neretnieks, Ivars

    2007-08-01

    Single-Well-Injection-Withdrawal, SWIW, tests are used to try to extract information on fracture apertures, sorption and diffusion properties and dispersion information in individual fractures. It is done by injecting a given amount of traced water into an isolated fracture. After a waiting period water is withdrawn from the fracture and the tracer concentration is measured. The concentration time curve is fitted to a model and the parameter values quantifying the different interaction mechanisms are determined. A number of different mechanisms influence the recovery of the tracer. One or more of the following mechanisms are considered. They include: dispersion due to velocity differences, sorption on fracture surface and on infill, diffusion in rock fragments in the fracture, diffusion between 'streamlines', diffusion into rock matrix and other stagnant water volumes, sorption kinetics and slow drift of the plume caused by the natural gradient. Many of the interaction mechanisms can influence the recovery curve in a similar way. For example, diffusion into rock matrix water and into stagnant water in the fracture adjacent to the flowing channels cannot be distinguished if only one tracer is used. Tracers with different properties can in principle be used but they will encounter different parts of the fracture, the sorbing tracer will move out less from the injection point than a nonsorbing tracer will. Diffusion and sorption in small particles in the flowpath can influence the recovery curve in a similar way as rock matrix diffusion does. Dispersion caused by diffusion between 'streamlines', Taylor dispersion, can give very different results in channels of different shapes. Such dispersion effects can be difficult to distinguish from matrix diffusion effects. Dispersion coefficients obtained in a SWIW test may have little relation to dispersion of a tracer moving from A to B. This is partly due to the different mechanisms and partly due to different time scales

  3. Single well injection withdrawal tests (SWIW) in fractured rock. Some aspects on interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Neretnieks, Ivars [Dept. of Chemical Engineering and Technology, Royal Inst. of Technology, Stockholm (Sweden)

    2007-08-15

    Single-Well-Injection-Withdrawal, SWIW, tests are used to try to extract information on fracture apertures, sorption and diffusion properties and dispersion information in individual fractures. It is done by injecting a given amount of traced water into an isolated fracture. After a waiting period water is withdrawn from the fracture and the tracer concentration is measured. The concentration time curve is fitted to a model and the parameter values quantifying the different interaction mechanisms are determined. A number of different mechanisms influence the recovery of the tracer. One or more of the following mechanisms are considered. They include: dispersion due to velocity differences, sorption on fracture surface and on infill, diffusion in rock fragments in the fracture, diffusion between 'streamlines', diffusion into rock matrix and other stagnant water volumes, sorption kinetics and slow drift of the plume caused by the natural gradient. Many of the interaction mechanisms can influence the recovery curve in a similar way. For example, diffusion into rock matrix water and into stagnant water in the fracture adjacent to the flowing channels cannot be distinguished if only one tracer is used. Tracers with different properties can in principle be used but they will encounter different parts of the fracture, the sorbing tracer will move out less from the injection point than a nonsorbing tracer will. Diffusion and sorption in small particles in the flowpath can influence the recovery curve in a similar way as rock matrix diffusion does. Dispersion caused by diffusion between 'streamlines', Taylor dispersion, can give very different results in channels of different shapes. Such dispersion effects can be difficult to distinguish from matrix diffusion effects. Dispersion coefficients obtained in a SWIW test may have little relation to dispersion of a tracer moving from A to B. This is partly due to the different mechanisms and partly due to

  4. Summary of air permeability data from single-hole injection tests in unsaturated fractured tuffs at the Apache Leap Research Site: Results of steady-state test interpretation

    International Nuclear Information System (INIS)

    Guzman, A.G.; Geddis, A.M.; Henrich, M.J.; Lohrstorfer, C.F.; Neuman, S.P.

    1996-03-01

    This document summarizes air permeability estimates obtained from single hole pneumatic injection tests in unsaturated fractured tuffs at the Covered Borehole Site (CBS) within the larger apache Leap Research Site (ALRS). Only permeability estimates obtained from a steady state interpretation of relatively stable pressure and flow rate data are included. Tests were conducted in five boreholes inclined at 45 degree to the horizontal, and one vertical borehole. Over 180 borehole segments were tested by setting the packers 1 m apart. Additional tests were conducted in segments of lengths 0.5, 2.0, and 3.0 m in one borehole, and 2.0 m in another borehole, bringing the total number of tests to over 270. Tests were conducted by maintaining a constant injection rate until air pressure became relatively stable and remained so for some time. The injection rate was then incremented by a constant value and the procedure repeated. The air injection rate, pressure, temperature, and relative humidity were recorded. For each relatively stable period of injection rate and pressure, air permeability was estimated by treating the rock around each test interval as a uniform, isotropic porous medium within which air flows as a single phase under steady state, in a pressure field exhibiting prolate spheroidal symmetry. For each permeability estimate the authors list the corresponding injection rate, pressure, temperature and relative humidity. They also present selected graphs which show how the latter quantities vary with time; logarithmic plots of pressure versus time which demonstrate the importance of borehole storage effects during the early transient portion of each incremental test period; and semilogarithmic plots of pressure versus recovery time at the end of each test sequence

  5. [Utility and advantages of single tracer subareolar injection in sentinel lymph node biopsy in breast cancer].

    Science.gov (United States)

    Armas, Fayna; Hernández, María Jesús; Vega, Víctor; Gutiérrez, Isabel; Jiménez, Concepción; Pavcovich, Marta; Báez, Beatriz; Pérez-Correa, Pedro; Núñez, Valentín

    2005-10-01

    Sentinel lymph node (SLN) biopsy is a reliable technique for determining axillary status in patients with early breast cancer. This technique is a minimally invasive procedure that can avoid the use of lymphadenectomy in patients without axillary involvement. We present a validation study of SLN biopsy with subareolar injection of 99mTc-nanocolloids. We studied 100 patients with early breast cancer (T1 and T2) over a 2-year period. All patients underwent deep subareolar-injection of 99mTc-nanocoloid for localization of the sentinel node. Images were obtained and when the sentinel node was seen, it was marked on the skin. All patients underwent tumor excision and radioguided SLN biopsy followed by complete lymphadenectomy. Histopathological analysis of sentinel nodes was performed by hematoxylin-eosin and immunohistochemistry with cytokeratins. The sentinel node was identified in all patients, and a mean of 1.95 sentinel nodes per patient were found. Lymphatic metastases in the sentinel node were found in 44 patients and in 15 of these tumoral spread was also found in the remaining axillary nodes. In the 56 remaining patients the sentinel node was free of metastasis, but in two of them a non-sentinel node was found to be positive (4.5% false negative rate). Sensitivity was 95.7% (44/46), specificity was 100% (54/54), the positive predictive value was 100% and the negative predictive value was 96.4% (54/56). SLN biopsy is an accurate alternative to complete axillary lymph node dissection in patients with early-stage breast cancer. This technique improves the staging of these patients and decreases the morbidity associated with lymphadenectomy. The advantages of subareolar injection are that a single injection site is required, the tumor does not have to be located by other techniques, it allows rapid visualization of the sentinel node and avoids the "shine through phenomenon" when the tumor is located near the axilla.

  6. AA injection kicker in its tank

    CERN Multimedia

    CERN PhotoLab

    1980-01-01

    For single-turn injection of the antiprotons, a septum at the end of the injection line made the beam parallel to the injection orbit, and a quarter of a betatron-wavelength downstream a fast kicker corrected the angle. Kicker type: lumped delay line. PFN voltage 56 kV. Bending angle 7.5 mrad; kick-strength 0.9 Tm; fall-time 95%-5% in 150 ns. The injection orbit is to the left, the stack orbit to the far right. A fast shutter near the central orbit had to be closed before the kicker fired, so as to protect the stack core from being shaken by the kicker's fringe field. The shutter is shown in closed position.

  7. Methodological study on determining endogenous amino acid excretion of broiler chickens by single intravenous injection of 3H-leucine

    International Nuclear Information System (INIS)

    Yao Junhu; Wang Kangning; Yang Feng; Zhou Anguo; Cai Xuelin; Duanmu Dao

    1999-01-01

    Forty broiler chickens (1.5 kg of body weight, BW) were randomly divided into 20 groups. Every fifth group was force-fed a nitrogen-free diet (NFD) or a NFd + 3.20% enzyme hydrolysed casein (EHC) diet or diets with 5% and 20% crude protein (CP) in which soybean meal (sol.) was the sole nitrogen source. 30μCi 3 H-leucine/kg BW was intravenously injected into all birds just after the force-feeding. Venous blood samples were taken at 5 min, 4h, 24h, 36h and 48h after the injection, and the amount of excreta for the whole period of 48h was collected. The amino acids excreted after force-feeding NFD + 3.20% EHC of CP5% diet were theoretically endogenous. The ratios of specific radioactivity (SR) in excreta and the value of definite integral in free plasma from 0 to 48 h after injection of labelled leucine were not different (P > 0.05) when NFD, NFD + 3.20% EHC or CP5% diet was fed. From these results and theoretical analysis, it was suggested that for the birds with CP20% diet, the ratio of SR in endogenous leucine and value of definite integral in free plasma from 0 to 48 h after injection of labelled leucine would be the same as that of the birds with NFD diet, and thus endogenous losses of leucine and other amino acids, by the endogenous amino acid pattern measured with NFD diet, could be estimated for CP20% diet. The endogenous amino acid losses measured by this new technique was 120.50% of those measured by NFD method. It was suggested that single intravenous injection of 3 H-leucine first proposed would be more valuable for determining endogenous amino acid losses, especially when practical nitrogen-containing diet was fed

  8. Sonographically guided deep plantar fascia injections: where does the injectate go?

    Science.gov (United States)

    Maida, Eugene; Presley, James C; Murthy, Naveen; Pawlina, Wojciech; Smith, Jay

    2013-08-01

    To determine the distribution of sonographically guided deep plantar fascia injections in an unembalmed cadaveric model. A single experienced operator completed 10 sonographically guided deep plantar fascia injections in 10 unembalmed cadaveric specimens (5 right and 5 left) obtained from 6 donors (2 male and 4 female) aged 49 to 95 years (mean, 77.5 years) with a mean body mass index of 23.2 kg/m(2) (range, 18.4-26.3 kg/m(2)). A 12-3-MHz linear array transducer was used to direct a 22-gauge, 38-mm stainless steel needle deep to the plantar fascia at the anterior aspect of the calcaneus using an in-plane, medial-to-lateral approach. In each case, 1.5 mL of 50% diluted colored latex was injected deep to the plantar fascia. After a minimum of 72 hours, study coinvestigators dissected each specimen to assess injectate placement. All 10 injections accurately placed latex adjacent to the deep side of the plantar fascia at the anterior calcaneus. However, the flexor digitorum brevis (FDB) origin from the plantar fascia variably limited direct latex contact with the plantar fascia, and small amounts of latex interdigitated with the FDB origin in 90% (9 of 10). In all 10 specimens, latex also covered the traversing first branch of the lateral plantar nerve (FBLPN, ie, Baxter nerve) between the FDB and quadratus plantae muscles. No latex was found in the plantar fat pad or plantar fascia in any specimen. Sonographically guided deep plantar fascia injections reliably deliver latex deep to the plantar fascia while avoiding intrafascial injection. However, the extent of direct plantar fascia contact is variable due to the intervening FDB. On the contrary, the traversing FBLPN is reliably covered by the injection. Deep plantar fascia injections may have a role in the management of refractory plantar fasciitis, particularly following failed superficial perifascial or intrafascial injections, in cases of preferential deep plantar fascia involvement, or when entrapment

  9. External and Intraparticle Diffusion of Coumarin 102 with Surfactant in the ODS-silica Gel/water System by Single Microparticle Injection and Confocal Fluorescence Microspectroscopy

    OpenAIRE

    NAKATANI, Kiyoharu; MATSUTA, Emi

    2015-01-01

    The release mechanism of coumarin 102 from a single ODS-silica gel microparticle into the water phase in the presence of Triton X-100 was investigated by confocal fluorescence microspectroscopy combined with the single microparticle injection technique. The release rate significantly depended on the Triton X-100 concentration in the water phase and was not limited by diffusion in the pores of the microparticle. The release rate constant was inversely proportional to the microparticle radius s...

  10. Lung deposition and extrapulmonary translocation of nano-ceria after intratracheal instillation

    International Nuclear Information System (INIS)

    He Xiao; Zhang Haifeng; Ma Yuhui; Bai Wei; Zhang Zhiyong; Ding Yayun; Zhao Yuliang; Chai Zhifang; Lu Kai

    2010-01-01

    The broad potential applications of manufactured nanomaterials call for urgent assessment of their environmental and biological safety. However, most of the previous work focused on the cell level performance; little was known about the consequences of nanomaterial exposure at the whole-body and organ levels. In the present paper, the radiotracer technique was employed to study the pulmonary deposition and the translocation to secondary target organs after ceria nanoparticles (nano-ceria) were intratracheally instilled into Wistar rats. It was found that 63.9 ± 8.2% of the instilled nano-ceria remained in the lung by 28 d postexposure and the elimination half-life was 103 d. At the end of the test period, only 1/8-1/3 of the daily elimination of nano-ceria from the lung was cleared via the gastrointestinal tract, suggesting that phagocytosis by alveolar macrophages (AMs) with subsequent removal towards the larynx was no longer the predominant route for the elimination of nano-ceria from the lung. The whole-body redistribution of nano-ceria demonstrated that the deposited nano-ceria could penetrate through the alveolar wall into the systemic circulation and accumulate in the extrapulmonary organs. In vitro study suggested that nano-ceria would agglomerate and form sediments in the bronchoalveolar aqueous surrounding while binding to protein would be conducive to the redispersion of nano-ceria. The decrease in the size of agglomerates might enhance the penetration of nano-ceria into the systemic circulation. Our findings suggested that the effect of nanomaterial exposure, even at low concentration, should be assessed because of the potential lung and systemic cumulative toxicity of the nanomaterials.

  11. Cardiovascular effects in rats after intratracheal instillation of metal welding particles.

    Science.gov (United States)

    Zheng, Wen; Antonini, James M; Lin, Yen-Chang; Roberts, Jenny R; Kashon, Michael L; Castranova, Vincent; Kan, Hong

    2015-01-01

    Studies have indicated that pulmonary exposure to welding fumes can induce a series of adverse effects in the respiratory system, including infection, bronchitis, siderosis and decreased pulmonary function. Recent clinical and epidemiological studies have found that pulmonary exposure to welding fumes is also associated with a higher incidence of cardiovascular events. However, there is insufficient evidence to confirm a direct effect of welding fumes on the cardiovascular system. The present study investigated the effects of pulmonary exposure to welding fumes on the heart and the vascular system in rats. Two chemically distinct welding fumes generated from manual metal arc-hard surfacing (MMA-HS) and gas metal arc-mild steel (GMA-MS) welding were tested. Three groups of rats were instilled intratracheally with MMA-HS (2 mg/rat), GMA-MS (2 mg/rat) or saline as control once a week for seven weeks. On days 1 and 7 after the last treatment, basal cardiovascular function and the cardiovascular response to increasing doses of adrenoreceptor agonists were assessed. MMA-HS treatment reduced the basal levels of left ventricle end-systolic pressure and dP/dt(max) at 1 day post-treatment, and decreased dP/dt(min) in response to isoproterenol (ISO) at 7 days post-treatment. Unlike MMA-HS, GMA-MS only affected left ventricular end-diastolic pressure in response to ISO at 7 days post-treatment. Treatment with MMA-HS or GMA-MS did not alter heart rate and blood pressure. Our findings suggest that exposure to different welding fumes can induce different adverse effects on the cardiovascular system, and that cardiac contractility may be a sensitive indicator of cardiovascular dysfunction.

  12. [Experimental study of an intratracheal stent made of shape memory alloy].

    Science.gov (United States)

    Yoshimura, M; Tsugawa, C; Tsubota, N

    1994-11-01

    To develop a new prosthesis for treating tracheal stenosis and tracheobronchomalacia, we examined the usefulness of an intratracheal stent made of shape memory alloy (SMA), a titanium-nickel alloy composed of 50% of each metal. At its recovery temperature (37 degrees C), the SMA stent was designed to recall the memorized shape of a coil with a diameter of 5 or 6 mm and a length of 10 mm. For the present experiment, it was transformed to a smaller coil 3 mm in diameter at a low temperature (-50 degrees C) and then loaded into the prosthesis introducer tube. An experimental model of potentially fatal tracheomalacia was made surgically by cutting and fracturing the tracheal cartilages of rabbits and tracheal collapse was confirmed by rigid bronchoscope. The introducer tube with the SMA stent was inserted and then the prosthesis was advanced into the collapsed segment of the trachea using the stent pusher. The SMA stent warmed bo body temperature and recovered its memorized shape after 1-2 min. In 3 out of 8 rabbits, follow-up bronchoscopy performed at 6, 8, and 10 months after implantation revealed satisfactory patency of the SMA stent and the trachea. After follow-up, 3 animals were sacrificed for histological observation, which showed little proliferation of granulation tissue and no dislocation of the SMA stent from the malacic portion. The remaining 5 rabbits have been followed for 18-24 months and are doing well. We conclude that the SMA stent maintains good tracheal patency, causes little reaction in the tracheal wall, and is easy to handle. Thus, it shows the potential for clinical application.

  13. C-stop production by micro injection moulding

    DEFF Research Database (Denmark)

    Islam, Aminul

    of engineering micro product which integrate many features like beam snapfit, annular snapfit, hinge connection, filter grid, house, lid etc in a single product. All the features are in micro dimensional scale and manufactured by single step of injection moulding. This presentation will cover industrial...

  14. The biological effects of radium-224 injected into dogs

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Hahn, F.F.; Boecker, B.B.

    1996-01-01

    A life-span study was conducted in 128 beagle dogs to determine the biological effects of intravenously injected 224 Ra chloride. The 224 Ra chloride was prepared by the same method used for intravenous injections in humans who were treated for ankylosing spondylitis and tuberculosis. Thus the results obtained from dogs can be compared directly to the population of treated humans, both for the elucidation of the effect of exposure rate and for comparison with other radionuclides for which data for humans are unavailable. Using equal numbers of males and females, the dogs were injected with one of four levels of 224 Ra resulting in initial body burdens of approximately 13, 40, 120 or 350 kBq of 224 Ra kg -1 body mass. A control group of dogs was injected with diluent only. All dogs were divided further into three groups for which the amount of injected 224 Ra (half-life of 3.62 days) or diluent was given in a single injection or divided equally into 10 or 50 weekly injections. As a result of these three injection schedules, the accumulation of dose from the injected 224 Ra was distributed over approximately 1, 3 or 12 months. Each injection schedule included four different injection levels resulting in average absorbed α-particle doses to bone of 0.1, 0.3, 1 and 3 Gy, respectively. The primary early effect observed was a hematological dyscrasia in the dogs receiving either of the two highest injection levels. The effect was most severe in the dogs receiving a single injection of 224 Ra and resulted in the death of three dogs injected at the highest level. The late-occurring biological effects were tumors. Bone tumors were the most common followed by tumors in the nasal mucosa. 52 refs., 8 figs., 8 tabs

  15. Selective injection locking of a multi-mode semiconductor laser to a multi-frequency reference beam

    Science.gov (United States)

    Pramod, Mysore Srinivas; Yang, Tao; Pandey, Kanhaiya; Giudici, Massimo; Wilkowski, David

    2014-07-01

    Injection locking is a well known and commonly used method for coherent light amplification. Usually injection locking is obtained on a single-mode laser injected by a single-frequency seeding beam. In this work we show that selective injection locking of a single-frequency may also be achieved on a multi-mode semiconductor laser injected by a multi-frequency seeding beam, if the slave laser provides sufficient frequency filtering. This selective injection locking condition depends critically on the frequency detuning between the free-running slave emission frequency and each injected frequency component. Stable selective injection locking to a set of three seeding components separated by 1.2 GHz is obtained. This system provides an amplification up to 37 dB of each component. This result suggests that, using distinct slave lasers for each frequency line, a set of mutually coherent high-power radiation modes can be tuned in the GHz frequency domain.

  16. Carcinogenicity of multi-walled carbon nanotubes: challenging issue on hazard assessment.

    Science.gov (United States)

    Fukushima, Shoji; Kasai, Tatsuya; Umeda, Yumi; Ohnishi, Makoto; Sasaki, Toshiaki; Matsumoto, Michiharu

    2018-01-25

    This report reviews the carcinogenicity of multi-walled carbon nanotubes (MWCNTs) in experimental animals, concentrating on MWNT-7, a straight fibrous MWCNT. MWCNTs were administered to mice and rats by intraperitoneal injection, intrascrotal injection, subcutaneous injection, intratracheal instillation and inhalation. Intraperitoneal injection of MWNT-7 induced peritoneal mesothelioma in mice and rats. Intrascrotal injection induced peritoneal mesothelioma in rats. Intratracheal instillation of MWCNT-N (another straight fibrous MWCNT) induced both lung carcinoma and pleural mesothelioma in rats. In the whole body inhalation studies, in mice MWNT-7 promoted methylcholanthrene-initiated lung carcinogenesis. In rats, inhalation of MWNT-7 induced lung carcinoma and lung burdens of MWNT-7 increased with increasing concentration of airborne MWNT-7 and increasing duration of exposure. Straight, fibrous MWCNTs exerted carcinogenicity in experimental animals. Phagocytosis of MWCNT fibers by macrophages was very likely to be a principle factor in MWCNT lung carcinogenesis. Using no-observed-adverse-effect level-based approach, we calculated that the occupational exposure limit (OEL) of MWNT-7 for cancer protection is 0.15 μg/m 3 for a human worker. Further studies on the effects of the shape and size of MWCNT fibers and mode of action on the carcinogenicity are required.

  17. Numerical Simulation of Single-anode and Double-anode Magnetron Injection Guns for 127.5 GHz 1 MW Gyrotron

    Science.gov (United States)

    Singh, Udaybir; Kumar, Nitin; Kumar, Anil; Purohit, Laxmi Prasad; Sinha, Ashok Kumar

    2011-07-01

    This paper presents the design of two types of magnetron injection guns (MIG's) for 1 MW, 127.5 GHz gyrotron. TE24,8 mode has been chosen as the operating mode. In-house developed code MIGSYN has been used to estimate the initial gun parameters. The electron trajectory tracing program EGUN and in-house developed code MIGANS have been used to optimize the single-anode and the double-anode design for 80 kV, 40 A MIG. The parametric analysis of MIG has also been presented. The advantages and the disadvantages of each kind of configuration have been critically examined.

  18. Complete Resolution of a Giant Pigment Epithelial Detachment Secondary to Exudative Age-Related Macular Degeneration after a Single Intravitreal Ranibizumab (Lucentis Injection: Results Documented by Optical Coherence Tomography

    Directory of Open Access Journals (Sweden)

    Eleni Loukianou

    2010-12-01

    Full Text Available Aim:To describe a patient with a giant pigment epithelial detachment (PED secondary to exudative age-related macular degeneration (ARMD successfully treated with a single intravitreal ranibizumab (Lucentis injection (0.5 mg/0.05 ml.Methods:An 89-year-old woman presented with a six-day history of reduced vision and distortion in the left eye. Best-corrected visual acuity in that eye was 6/15. Fundoscopy revealed a giant PED and exudates temporally to the fovea. Optical coherence tomography showed a PED associated with subretinal and intraretinal fluid. Fluorescein angiography confirmed the diagnosis of an occult choroidal neovascularization. Treatment with intravitreal injections of ranibizumab (Lucentis was recommended, although the increased risk of retinal pigment epithelium (RPE rip was mentioned. Results:Four weeks after the first intravitreal Lucentis injection, the visual acuity in the left eye improved to 6/7.5, with a significant improvement of the distortion and a complete anatomical resolution of the PED confirmed by optical coherence tomography. Conclusion:Giant PED secondary to exudative ARMD can be successfully treated with intravitreal ranibizumab, despite the increased risk of RPE rip. To our knowledge, this is the first case presenting with complete resolution of PED after a single ranibizumab injection.

  19. EXPERIMENTAL TARGET INJECTION AND TRACKING SYSTEM CONSTRUCTION AND SINGLE SHOT TESTING

    International Nuclear Information System (INIS)

    PETZOLDT, R.W.; ALEXANDER, N.B.; DRAKE, T.J.; GOODIN, D.T; JONESTRACK, K; VERMILLION, B.A

    2003-01-01

    Targets must be injected into an IFE power plant at a rate of approximately 5 to 10 Hz. Targets must be tracked very accurately to allow driver beams to be aligned with defined points on the targets with accuracy ± 150 (micro)m for indirect drive and ± 20 (micro)m for direct drive. An experimental target injection and tracking system has been constructed at General Atomics. The injector system will be used as a tool for testing the survivability of various target designs and provide feedback to the target designers. Helium gas propels the targets down an 8 m gun barrel up to 400 m/s. Direct-drive targets are protected in the barrel by sabots that are spring loaded to separate into two halves after acceleration. A sabot deflector directs the sabot halves away from the target injection path. Targets will be optically tracked with laser beams and line-scan cameras. Target position and arrival time will be predicted in real time based on early target position measurements. The system installation will be described. System testing to overcome excessive projectile wear and debris in the gun barrel is presented

  20. Single beam pass migmacell method and apparatus

    International Nuclear Information System (INIS)

    Maglich, B.C.; Nering, J.E.; Mazarakis, M.G.; Miller, R.A.

    1976-01-01

    The invention provides improvements in migmacell apparatus and method by dispensing with the need for metastable confinement of injected molecular ions for multiple precession periods. Injected molecular ions undergo a 'single pass' through the reaction volume. By preconditioning the injected beam such that it contains a population distribution of molecules in higher vibrational states than in the case of a normal distribution, injected molecules in the single pass exper-ience collisionless dissociation in the migmacell under magnetic influence, i.e., so-called Lorentz dissociation. Dissociationions then form atomic migma

  1. Pseudorandom binary injection of levitons for electron quantum optics

    Science.gov (United States)

    Glattli, D. C.; Roulleau, P.

    2018-03-01

    The recent realization of single-electron sources lets us envision performing electron quantum optics experiments, where electrons can be viewed as flying qubits propagating in a ballistic conductor. To date, all electron sources operate in a periodic electron injection mode, leading to energy spectrum singularities in various physical observables which sometimes hide the bare nature of physical effects. To go beyond this, we propose a spread-spectrum approach where electron flying qubits are injected in a nonperiodic manner following a pseudorandom binary bit pattern. Extending the Floquet scattering theory approach from periodic to spread-spectrum drive, the shot noise of pseudorandom binary sequences of single-electron injection can be calculated for leviton and nonleviton sources. Our new approach allows us to disentangle the physics of the manipulated excitations from that of the injection protocol. In particular, the spread-spectrum approach is shown to provide better knowledge of electronic Hong-Ou-Mandel correlations and to clarify the nature of the pulse train coherence and the role of the dynamical orthogonality catastrophe for noninteger charge injection.

  2. Biological fate of a single administration of 191Pt in rats following different routes of exposure

    International Nuclear Information System (INIS)

    Moore, W. Jr.; Hysell, D.; Crocker, W.; Stara, J.

    1975-01-01

    The retention, tissue distribution, and excretion of 191 Pt in adult rats was determined following oral, intravenous (IV), and intratracheal administration. The highest retention was obtained following IV dosing, and lowest retention (less than 0.5 percent) occurred after oral dosing. Tissues containing the highest concentrations of 191 Pt following IV administration were the kidney, adrenal, spleen, and liver. Following a single oral dose, almost all of the 191 Pt was excreted in the feces due to nonabsorption, whereas after IV dosing, similar quantities were excreted in both the urine and feces. Following IV dosing of pregnant rats, 191 Pt was found in all the fetuses; however, the amount was small

  3. 40 CFR 146.5 - Classification of injection wells.

    Science.gov (United States)

    2010-07-01

    ... establishment septic tank. The UIC requirements do not apply to single family residential septic system wells, nor to non-residential septic system wells which are used solely for the disposal of sanitary waste... whether what is injected is a radioactive waste or not. (9) Septic system wells used to inject the waste...

  4. Do not rush to return to sports after trigger finger injection.

    Science.gov (United States)

    Oh, Jeehae; Jo, Leechan; Lee, Jong In

    2015-04-01

    Trigger finger, or digital stenosing tenosynovitis, is a common hand problem. A widely accepted treatment is steroid injection into the flexor tendon sheath. This can cause rupture of the flexor tendon. However, to the best of our knowledge, there is no report on tendon rupture after a single corticosteroid injection. Moreover, there are no guidelines for patients with tendinopathy who want to return to sports after corticosteroid injection. Clinicians who perform local steroid injections for tendinopathy treatment should be aware of the possible dangers of tendon rupture and should confirm that steroids are not administrated into the tendon. Patients should also be warned about returning to sports prematurely and should be encouraged to gradually resume sports after the injection to prevent further damage. Herein, we report an unusual case of flexor digitorum profundus rupture after a single corticosteroid injection in a 57-yr-old male golfer and we also present a review of the literature.

  5. A PIV Study of Slotted Air Injection for Jet Noise Reduction

    Science.gov (United States)

    Henderson, Brenda S.; Wernet, Mark P.

    2012-01-01

    Results from acoustic and Particle Image Velocimetry (PIV) measurements are presented for single and dual-stream jets with fluidic injection on the core stream. The fluidic injection nozzles delivered air to the jet through slots on the interior of the nozzle at the nozzle trailing edge. The investigations include subsonic and supersonic jet conditions. Reductions in broadband shock noise and low frequency mixing noise were obtained with the introduction of fluidic injection on single stream jets. Fluidic injection was found to eliminate shock cells, increase jet mixing, and reduce turbulent kinetic energy levels near the end of the potential core. For dual-stream subsonic jets, the introduction of fluidic injection reduced low frequency noise in the peak jet noise direction and enhanced jet mixing. For dual-stream jets with supersonic fan streams and subsonic core streams, the introduction of fluidic injection in the core stream impacted the jet shock cell structure but had little effect on mixing between the core and fan streams.

  6. Identification of Hürthle cell tumor by single-injection, double-phase scintigraphy with technetium-99m-sestamibi.

    Science.gov (United States)

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A

    1995-05-01

    Early and late (double-phase) scintigraphy with 99mTc-MIBI was used in a comparative study of the scintigraphic aspects of Hürthle cell tumors and other thyroid tumors. Single-injection, dual-phase (15-30 min and 3-4 hr) thyroid scintigraphy with 99mTc-sestamibi (MIBI) was performed on 41 patients who displayed a cold nodule on previous 99mTc scintigraphy. Visual scoring of nodular uptake was done to compare thyroidal and background tracer uptake. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late images and the washout rate from the nodule (WON) and thyroidal tissue (WOT) were measured. Cytologic results were obtained for all patients; histopathologic results were obtained for the 20 patients who had surgery. In eight patients (Group A), the nodule displayed intense and persistent uptake of MIBI (N/T = 1.77 +/- 0.46 and 3.20 +/- 1.37; WON = 17.2% +/- 6.3%; WOT = 24.6% +/- 7.5%); histopathology revealed Hürthle cell tumors (two carcinomas and three adenomas) in five surgical patients. In 15 patients (Group B), the nodule displayed intense uptake in the early image with fading activity in the late image (N/T = 1.45 +/- 0.54 and 0.84 +/- 0.30; WON = 30.0% +/- 7.3%; WOT = 24.5% +/- 6.8%); histopathology revealed a colloid nodule (n = 1), papillary carcinoma (n = 4) and follicular carcinoma (n = 5) in 10 surgical patients. In the remaining 18 patients (Group C), the nodule was cold and late images were not acquired. Histopathology revealed colloid nodules (n = 2) and follicular adenoma (n = 3) in five surgical patients. Single-injection, dual-phase MIBI scintigraphy of the thyroid can identify Hürthle cell tumors because these tumors have intense, persistent tracer uptake in contrast to other thyroid tumors.

  7. An injection seeded single frequency Nd:YAG Q-switched laser with precisely controllable laser pulse firing time

    Science.gov (United States)

    Wu, Frank F.; Khizhnyak, Anatoliy; Markov, Vladimir

    2010-02-01

    We have realized a single frequency Q-switched Nd:YAG laser with precisely controllable lasing time and thus enabled synchronization of multi-laser systems. The use of injection seeding to the slave ring oscillator results in unidirectional Q-switched laser oscillation with suppression of bidirectional Q-switched oscillation that otherwise would be initiated from spontaneous emission if the seeding laser is not present. Under normal condition, the cavity is high in loss during the pumping period; then a Pockels cell opens the cavity to form the pulse build up, with a second Pockels cell to perform cavity dumping, generating the Q-switched pulse output with optimized characteristics. The two Pockels cells can be replaced by a single unit if an adjustable gated electrical pulse is applied to the Pockels cell in which the pulse front is used to open the cavity and the falling edge to dump the laser pulse. Proper selection of the pump parameters and Pockels-cell gating enables operation of the system in a mode in which the Q-switched pulse can be formed only under the seeding condition. The advantage of the realized regime is in stable laser operation with no need in adjustment of the seeded light wavelength and the mode of the cavity. It is found that the frequency of the Q-switched laser radiation matches well to the injected seeded laser mode. By using two-stage amplifiers, an output energy better than 300 mJ has been achieved in MOPA configuration without active control of the cavity length and with pulse width adjustability from several nanoseconds to 20 ns. The Q-switched oscillator operates not only at precisely controlled firing time but also can be tuned over wide range. This will enable multi-laser systems synchronization and frequency locking down each other if necessary.

  8. Acute inflammatory reaction in rats after intratracheal instillation of material collected from a nylon flocking plant.

    Science.gov (United States)

    Porter, D W; Castranova, V; Robinson, V A; Hubbs, A F; Mercer, R R; Scabilloni, J; Goldsmith, T; Schwegler-Berry, D; Battelli, L; Washko, R; Burkhart, J; Piacitelli, C; Whitmer, M; Jones, W

    1999-05-14

    Several cases of interstitial lung disease have been diagnosed among workers at a nylon flock plant, but the etiologic agent for the disease outbreak was unknown. The results of a medical survey and industrial hygiene study indicated that the dust present in the plant may be responsible. Thus, airborne dust collected at the plant was examined for its inflammatory potential in rat lungs. The endpoints measured were: (1) breathing rates, (2) differential cell counts of bronchoalveolar lavage cells, (3) alveolar macrophage (AM) chemiluminescence, (4) albumin concentration and matrix metalloprotease activities in the acellular fluid from the initial bronchoalveolar lavage, and (5) pulmonary histopathology. In the first study, rats received a single dose of the airborne dust sample (10 mg/kg body weight) by intratracheal (IT) instillation. At 1 d post-IT, all inflammatory endpoints were significantly increased versus controls, but by 29 d post-IT they did not differ significantly from controls. Histopathology demonstrated mild to moderate, multifocal, suppurative pneumonia, usually centered around bronchioles, at 1 d post-IT. At 29 d post-IT, pulmonary inflammation was minimal to mild and characterized by alveolar histocytosis usually restricted to the immediate area of retained bire-fringent fibers. In subsequent experiments, airborne dust was extracted with water and the dust (washed airborne dust) and water extract (soluble fraction) were separated by centrifugation for further study. Nylon tow dust was prepared in the laboratory by milling uncut nylon strands (called tow) that had not been treated with the finish or dyes that are commonly used in the flock plants. Rats were administered a single dose of a dust sample (10 mg/kg body weight) or the soluble fraction (1.3 ml/kg body weight) by IT administration and the same endpoints were measured at 1 d post-IT. The dust samples caused significant increases in all of the inflammatory endpoints; however, the soluble

  9. A single exposure to cocaine during development elicits regionally-selective changes in basal basic Fibroblast Growth Factor (FGF-2) gene expression and alters the trophic response to a second injection.

    Science.gov (United States)

    Giannotti, Giuseppe; Caffino, Lucia; Malpighi, Chiara; Melfi, Simona; Racagni, Giorgio; Fumagalli, Fabio

    2015-02-01

    During adolescence, the brain is maturing and more sensitive to drugs of abuse that can influence its developmental trajectory. Recently, attention has been focused on basic fibroblast growth factor (FGF-2) given that its administration early in life enhances the acquisition of cocaine self-administration and sensitization at adulthood (Turner et al. (Pharmacol Biochem Behav 92:100-4, 2009), Clinton et al. (Pharmacol Biochem Behav103:6-17, 2012)). Additionally, we found that abstinence from adolescent cocaine exposure long lastingly dysregulates FGF-2 transcription (Giannotti et al. (Psychopharmacology (Berl) 225:553-60, 2013 ). The objectives of the study are to evaluate if (1) a single injection of cocaine (20 mg/kg) at postnatal day 35 alters FGF-2 messenger RNA (mRNA) levels and (2) the first injection influences the trophic response to a second injection (10 mg/kg) provided 24 h or 7 days later. We found regional differences in the FGF-2 expression pattern as either the first or the second injection of cocaine by themselves upregulated FGF-2 mRNA in the medial prefrontal cortex and nucleus accumbens while downregulating it in the hippocampus. The first injection influences the trophic response of the second. Of note, 24 h after the first injection, accumbal and hippocampal FGF-2 changes produced by cocaine in saline-pretreated rats were prevented in cocaine-pretreated rats. Conversely, in the medial prefrontal cortex and hippocampus 7 days after the first injection, the cocaine-induced FGF-2 changes were modified by the subsequent exposure to the psychostimulant. These findings show that a single cocaine injection is sufficient to produce enduring changes in the adolescent brain and indicate that early cocaine priming alters the mechanisms regulating the trophic response in a brain region-specific fashion.

  10. Myocardial blood flow rate and capillary permeability for 99mTc-DTPA in patients with angiographically normal coronary arteries. Evaluation of the single-injection, residue detection method with intracoronary indicator bolus injection and the use of a mobile gamma camera

    DEFF Research Database (Denmark)

    Svendsen, Jesper Hastrup; Kelbaek, H; Efsen, F

    1994-01-01

    The aims of the present study were to quantitate myocardial perfusion and capillary permeability in the human heart by means of the single-injection, residue detection method using a mobile gamma camera. With this method, the intravascular mean transit time and the capillary extraction fraction (E...

  11. Direct injection of high pressure gas : scaling properties of pulsed turbulent jets

    NARCIS (Netherlands)

    Baert, R.S.G.; Klaassen, A.; Doosje, E.

    2010-01-01

    Existing gasoline DI injection equipment has been modified to generate single hole pulsed gas jets. Injection experiments have been performed at combinations of 3 different pressure ratios (2 of which supercritical) respectively 3 different hole geometries (i.e. length to diameter ratios). Injection

  12. External and Intraparticle Diffusion of Coumarin 102 with Surfactant in the ODS-silica Gel/water System by Single Microparticle Injection and Confocal Fluorescence Microspectroscopy.

    Science.gov (United States)

    Nakatani, Kiyoharu; Matsuta, Emi

    2015-01-01

    The release mechanism of coumarin 102 from a single ODS-silica gel microparticle into the water phase in the presence of Triton X-100 was investigated by confocal fluorescence microspectroscopy combined with the single microparticle injection technique. The release rate significantly depended on the Triton X-100 concentration in the water phase and was not limited by diffusion in the pores of the microparticle. The release rate constant was inversely proportional to the microparticle radius squared, indicating that the rate-determining step is the external diffusion between the microparticle and the water phase.

  13. External and intraparticle diffusion of coumarin 102 with surfactant in the ODS-silica gel/water system by single microparticle injection and confocal fluorescence microspectroscopy

    International Nuclear Information System (INIS)

    Nakatani, Kiyoharu; Matsuta, Emi

    2015-01-01

    The release mechanism of coumarin 102 from a single ODS-silica gel microparticle into the water phase in the presence of Triton X-100 was investigated by confocal fluorescence microspectroscopy combined with the single microparticle injection technique. The release rate significantly depended on the Triton X-100 concentration in the water phase and was not limited by diffusion in the pores of the microparticle. The release rate constant was inversely proportional to the microparticle radius squared, indicating that the rate-determining step is the external diffusion between the microparticle and the water phase. (author)

  14. Adaptation of a load-inject valve for a flow injection chemiluminescence system enabling dual-reagent injection enhances understanding of environmental Fenton chemistry

    International Nuclear Information System (INIS)

    Jones, Matthew R.; Nightingale, Philp D.; Turner, Suzanne M.; Liss, Peter S.

    2013-01-01

    Graphical abstract: -- Highlights: •Measurement of multiple components of Fenton chemistry; Fe(II) and H 2 O 2 . •Rapid, quasi-simultaneous analysis enables calculation of environmental kinetics. •Low, nano to pico-molar detection limits with dual analyte analysis. •Able to measure complex matrix samples – organically enriched seawater. •Low cost system with appreciable sensitivity compared to single analyte analysis. -- Abstract: Environmental Fenton chemistry has been poorly constrained within the marine environment at a multi-component level. A simple, unique, reconfiguration of a flow-injection analytical system combined with luminol chemiluminescence allows quasi-simultaneously the measurement, using a single load-inject valve and a single photon multiplier tube, of reduced iron, Fe(II), and hydrogen peroxide. The system enables rapid, every 22 s, measurements with good accuracy at environmentally relevant concentrations, less than 5% relative standard deviations on both a 5 nM Fe(II) standard and a 60 nM hydrogen peroxide standard. Limits of detection were as low as 40 pM Fe(II) and 100 pM hydrogen peroxide. The system showed excellent capability by measuring from within an organic rich seawater the photochemically induced production of Fe(II) and hydrogen peroxide and their subsequent cycling and Fenton like interactions

  15. Improved healing of transected rabbit Achilles tendon after a single injection of cartilage-derived morphogenetic protein-2.

    Science.gov (United States)

    Forslund, Carina; Aspenberg, Per

    2003-01-01

    Achilles tendon ruptures in humans might be treated more efficiently with the help of a growth factor. Cartilage-derived morphogenetic protein-2 has been shown to induce formation of tendon-like tissue. Cartilage-derived morphogenetic protein-2 has a positive effect on mechanical parameters for tendon healing in a rabbit model with Achilles tendon transection. Controlled laboratory study. The right Achilles tendon of 40 rabbits was transected without tendon suture. Cartilage-derived morphogenetic protein-2 (10 micro g) or vehicle control (acetate buffer) was injected locally 2 hours postoperatively. All tendons were tested biomechanically at 8 and 14 days, and treated tendons were histologically and radiographically evaluated at 56 days. At 14 days, both failure load and stiffness of treated tendons were increased by 35%. The treated tendons had significantly larger callus size at 8 and 14 days. Histologic and radiographic examination showed no signs of ossification in the treated tendons after 56 days. A single injection of cartilage-derived morphogenetic protein-2 led to a stronger and stiffer tendon callus than that in the controls without inducing bone formation. Similar results from a larger animal model would suggest a possible future use of cartilage-derived morphogenetic protein-2 in the treatment of human Achilles tendon ruptures.

  16. Modelling the effect of injection pressure on heat release parameters and nitrogen oxides in direct injection diesel engines

    Directory of Open Access Journals (Sweden)

    Yüksek Levent

    2014-01-01

    Full Text Available Investigation and modelling the effect of injection pressure on heat release parameters and engine-out nitrogen oxides are the main aim of this study. A zero-dimensional and multi-zone cylinder model was developed for estimation of the effect of injection pressure rise on performance parameters of diesel engine. Double-Wiebe rate of heat release global model was used to describe fuel combustion. extended Zeldovich mechanism and partial equilibrium approach were used for modelling the formation of nitrogen oxides. Single cylinder, high pressure direct injection, electronically controlled, research engine bench was used for model calibration. 1000 and 1200 bars of fuel injection pressure were investigated while injection advance, injected fuel quantity and engine speed kept constant. The ignition delay of injected fuel reduced 0.4 crank angle with 1200 bars of injection pressure and similar effect observed in premixed combustion phase duration which reduced 0.2 crank angle. Rate of heat release of premixed combustion phase increased 1.75 % with 1200 bar injection pressure. Multi-zone cylinder model showed good agreement with experimental in-cylinder pressure data. Also it was seen that the NOx formation model greatly predicted the engine-out NOx emissions for both of the operation modes.

  17. Systematic assessment of microneedle injection into the mouse cornea.

    Science.gov (United States)

    Matthaei, Mario; Meng, Huan; Bhutto, Imran; Xu, Qingguo; Boelke, Edwin; Hanes, Justin; Jun, Albert S

    2012-06-20

    Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. A mean corneal area of 5.0 ± 1.4 mm(2) (mean ± SD) and 7.7 ± 1.4 mm(2) was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively of total corneal area involved.

  18. Influence of heat exchange of reservoir with rocks on hot gas injection via a single well

    Science.gov (United States)

    Nikolaev, Vladimir E.; Ivanov, Gavril I.

    2017-11-01

    In the computational experiment the influence of heat exchange through top and bottom of the gas-bearing reservoir on the dynamics of temperature and pressure fields during hot gas injection via a single well is investigated. The experiment was carried out within the framework of modified mathematical model of non-isothermal real gas filtration, obtained from the energy and mass conservation laws and the Darcy law. The physical and caloric equations of state together with the Newton-Riemann law of heat exchange of gas reservoir with surrounding rocks, are used as closing relations. It is shown that the influence of the heat exchange with environment on temperature field of the gas-bearing reservoir is localized in a narrow zone near its top and bottom, though the size of this zone is increased with time.

  19. Spin-injection into epitaxial graphene on silicon carbide

    Science.gov (United States)

    Konishi, Keita; Cui, Zhixin; Hiraki, Takahiro; Yoh, Kanji

    2013-09-01

    We have studied the spin-injection properties in epitaxial graphene on SiC. The ferromagnetic metal (FM) electrodes were composed of a tunnel barrier layer AlOx (14 Å) and a ferromagnetic Co (600 Å) layer. We have successfully observed the clear resistance peaks indicating spin-injection both in the "local" and "non-local" spin measurement set-ups at low temperatures. We estimate spin-injection rate of 1% based on "non-local" measurement and 1.6% based on local measurements. Spin-injection rate of multilayer graphene by mechanical exfoliation method was twice as high as single layer graphene on SiC based on "local" measurement.

  20. Predictive Factors of Patients' and Their Partners' Sexual Function Improvement After Collagenase Clostridium Histolyticum Injection for Peyronie's Disease: Results From a Multi-Center Single-Arm Study.

    Science.gov (United States)

    Cocci, Andrea; Russo, Giorgio Ivan; Salonia, Andrea; Cito, Gianmartin; Regis, Federica; Polloni, Gaia; Giubilei, Gianluca; Cacciamani, Giovanni; Capece, Marco; Falcone, Marco; Greco, Isabella; Timpano, Massimiliano; Minervini, Andrea; Gacci, Mauro; Cai, Tommaso; Garaffa, Giulio; Giammusso, Bruno; Arcaniolo, Davide; Mirone, Vincenzo; Mondaini, Nicola

    2018-05-01

    Collagenase Clostridium histolyticum (CCH; Xiapex) injections represent the only licensed medical treatment for Peyronie's disease (PD). To evaluate the efficacy and safety of CCH injections in men with stable PD, using a modified treatment protocol and to assess partners' bother improvement in a large cohort of White-European sexually active heterosexual men treated in a single tertiary-referral center. All the 135 patients enrolled underwent a thorough assessment, which included history taking, physical examination, and pharmacologically induced artificial erection test (intra-cavernous injection) to assess the degree of penile curvature (PC) at baseline and after the completion of the treatment. Patients with calcified plaque and/or ventral curvature were excluded. All patients underwent a modified treatment protocol, which consisted of 3 intra-lesional injections of 0.9 mg of CCH performed at 4-week intervals at the point of maximum curvature. After each injection, patients were instructed to follow a strict routine involving daily penile stretching in the intervals between injections. International Index of Erectile Function (IIEF)-15, Global Assessment of PD, PD questionnaires (PDQ), and Female Sexual Function Index (FSFI) questionnaire were performed at baseline and at the end of treatment. Overall, 135 patients completed the study protocol. Before treatment, 18 (13.33%) partners showed a degree of sexual dysfunction. Baseline median IIEF-15, FSFI, and PDQ scores were, respectively, 59.0, 35.0, and 23.0. Overall, both IIEF-total and all domains significantly improved after treatment (all P < .01). A PC mean change of 19.07 (P = .00) was measured. At the univariate linear regression analysis, IIEF-15, IIEF-erectile function, IIEF-sexual desire, and IIEF-intercourse satisfaction were positively associated with FSFI (all P ≤ .03); conversely, PDQ-penile pain, PDQ-symptom bother, and post-treament penile curvature (P ≤ .04) were associated with a decreased

  1. Multidose Botulinum Toxin A for Intralaryngeal Injection: A Cost Analysis.

    Science.gov (United States)

    Gilbert, Mark R; Young, VyVy N; Smith, Libby J; Rosen, Clark A

    2018-01-04

    Botulinum toxin A (BtxA) injection is the mainstay treatment for laryngeal dystonias. BtxA product labeling states that reconstituted toxin should be used within 4 hours on a single patient despite several studies that have demonstrated multidose BtxA to be safe and effective. Many insurance carriers mandate the use of an outside pharmacy which necessitates a single-use approach. This study compares the cost savings of multidose BtxA for laryngeal dystonia compared to single-use. This is a retrospective review and projected cost savings analysis. Records and billing information were reviewed for patients receiving BtxA for intralaryngeal injection at a single laryngology division in 2015. Inclusion criteria included CPT 64617 or J0585; exclusion criteria included CPT 64616. The price of BtxA 100 unit vial for calculation was $670. A total of 142 patients were seen for intralaryngeal BtxA injection resulting in 337 visits over 1 year. The average BtxA dose per visit was 2.86 units with an average of 3.06 procedure visits per year. The calculated cost of BtxA treatment using a single vial approach was found to be $2,050 per patient per year. If billed instead for $7/unit with 5 units wastage charge per visit, the yearly per patient charge is $168. Single vial-use of BtxA injection thus represents a 1,118% price increase versus multidose use. When estimated for yearly prevalence of spasmodic dysphonia, multidose BtxA use would save almost $100 million annually. Multidose botulinum toxin A application utilizing per unit billing is significantly less expensive than per single-use vial billing and would save the health-care system significant amount of money without any sacrifice in safety or effectiveness. Copyright © 2018. Published by Elsevier Inc.

  2. 76 FR 22610 - Implantation or Injectable Dosage Form New Animal Drugs; Enrofloxacin

    Science.gov (United States)

    2011-04-22

    .... FDA-2011-N-0003] Implantation or Injectable Dosage Form New Animal Drugs; Enrofloxacin AGENCY: Food... the indications for use of enrofloxacin solution in cattle, as a single injection, for the treatment... supplement to NADA 141-068 for BAYTRIL 100 (enrofloxacin), an injectable solution. The supplemental NADA...

  3. Pellet injection in WVIIA

    International Nuclear Information System (INIS)

    Renner, H.; Wuersohing, E.; Weller, A.; Jaeckel, H.; Hartfuss, H.; Hacker, H.; Ringler, H.; Buechl, K.

    1986-01-01

    The results of pellet injection experiments in the Wendelstein VII A stellarator are presented. The injector was a single shot pneumatic gun using deuterium pellets. Experiments were carried out in both ECRH and NI plasmas. Data is shown for plasma density, energy confinement, penetration depth and pellet ablation. Results are compared to a neutral gas shielding model

  4. Embolic stroke associated with injection of buprenorphine tablets.

    Science.gov (United States)

    Lim, C C Tchoyoson; Lee, Sze Haur; Wong, Yee-Choon; Hui, Francis

    2009-09-15

    Drug users who crush, dissolve, and inject buprenorphine tablets parenterally may be at risk of severe thromboembolic complications or death. We describe patients with neurologic complications after injecting buprenorphine tablets. Brain MRI including diffusion-weighted imaging (DWI) in patients admitted to the neurologic department after injecting buprenorphine tablets were reviewed. Seven men had neurologic complications after buprenorphine tablet injection. In 5 patients, multiple small scattered hyperintense lesions were detected on DWI in the cortex, white matter, and basal ganglia of the cerebral hemisphere; one patient had a single small lesion. The side of MRI abnormality corresponded to the side of needle marks on the neck except in one patient who had bilateral injections. One patient, who denied injecting into the neck, had DWI abnormalities in the middle cerebral artery territory on one side and occlusion of the ipsilateral internal carotid artery. Buprenorphine tablets can be intentionally or inadvertently injected into the carotid artery, causing a characteristic appearance on diffusion-weighted imaging, consistent with embolic cerebral infarction.

  5. Curcumin protects dopaminergic neurons against inflammation-mediated damage and improves motor dysfunction induced by single intranigral lipopolysaccharide injection.

    Science.gov (United States)

    Sharma, Neha; Sharma, Sheetal; Nehru, Bimla

    2017-06-01

    Various studies have indicated a lower incidence and prevalence of neurological conditions in people consuming curcumin. The ability of curcumin to target multiple cascades, simultaneously, could be held responsible for its neuroprotective effects. The present study was designed to investigate the potential of curcumin in minimizing microglia-mediated damage in lipopolysaccharide (LPS) induced model of PD. Altered microglial functions and increased inflammatory profile of the CNS have severe behavioral consequences. In the current investigation, a single injection of LPS (5 ug/5 µl PBS) was injected into the substantia nigra (SN) of rats, and curcumin [40 mg/kg b.wt (i.p.)] was administered daily for a period of 21 days. LPS triggered an inflammatory response characterized by glial activation [Iba-1 and glial fibrillary acidic protein (GFAP)] and pro-inflammatory cytokine production (TNF-α and IL-1β) leading to extensive dopaminergic loss and behavioral abnormality in rats. The behavioral observations, biochemical markers, quantification of dopamine and its metabolites (DOPAC and HVA) using HPLC followed by IHC of tyrosine hydroxylase (TH) were evaluated after 21 days of LPS injection. Curcumin supplementation prevented dopaminergic degeneration in LPS-treated animals by normalizing the altered levels of biomarkers. Also, a significant improvement in TH levels as well as behavioral parameters (actophotometer, rotarod, beam walking and grid walking tests) were seen in LPS injected rats. Curcumin shielded the dopaminergic neurons against LPS-induced inflammatory response, which was associated with suppression of glial activation (microglia and astrocytes) and transcription factor NF-κB as depicted from RT-PCR and EMSA assay. Curcumin also suppressed microglial NADPH oxidase activation as observed from NADPH oxidase activity. The results suggested that one of the important mechanisms by which curcumin mediates its protective effects in the LPS-induced PD

  6. Safety and efficacy of multiuse botulinum toxin vials for intralaryngeal injection.

    Science.gov (United States)

    Barrow, Emily M; Rosen, Clark A; Hapner, Edie R; Smith, Sarah; Hatcher, Jeanne L; Simpson, Blake; Johns, Michael M

    2015-05-01

    Centers for Disease Control and Prevention guidelines maintain that single-use vials cannot be used for multiple patients. Botox product labeling states that the reconstituted toxin should be used within 4 hours on a single patient based on concerns of reduced potency, contamination, and consequent infections. The purpose of this study was to determine the safety and efficacy of using single-use vials in a multidose fashion. Prospective study and cohort chart review. A multi-institutional three-part study was performed between May 2013 and October 2013: 1) a summation of subjects' recall of their past experiences (symptoms/response) with previous multidose Botox injections, 2) a prospective study of intralaryngeal injections, and 3) a chart review of injection responses in a subset of the cohort. Seven hundred forty-three subjects receiving 6,216 injections demonstrated zero infection-related complications on retrospective chart review. One hundred seventy-nine subjects recalled 24.0% overall adverse events, 10.6% redness, 7.3% pain and swelling at the injection site, and 0% fever. One hundred seventy-four subjects prospectively reported 12.6% overall adverse events. The self-reported efficacy rate of Botox injection was 96.6%. The low rates of adverse events following the use of Botox in a multipatient fashion are consistent with other percutaneous injections. No evidence of infection was found with multidose Botox use. Given the low incidence of side effects and high success rate, Botox can be used both safely and effectively in a multipatient fashion. 4 © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  7. Identification and weighting factors influencing the establishment of a single minute exchange of dies in plastic injection industry using VIKOR and Shannon Entropy

    Directory of Open Access Journals (Sweden)

    Gholam Reza Hashemzadeh

    2014-05-01

    Full Text Available Single minute exchange of dies (SMED is one of the most important tools to achieve lean production system. The main idea of this system is to provide methods and to use creative and innovative solutions for continuous improvement. Due to the importance of this issue and its effect on reducing waste during the production process, this study presents a method to identify and to weight factors in the establishment of a single minute exchange of dies in 14 plastic injection factories. In this study, fourteen factories in injection industry were chosen and the factors influencing the implementation of single minute exchange of dies were identified. Following data collection, decision matrix was formed and the weight of each factor was determined by using Shannon Entropy. Then, in order to determine the readiness of factories, VIKOR method was used to rank companies. The results indicate priorities of the following factors in establishing SMED that include: Senior management support, technical capabilities, technical knowledge of staff and consultants, knowledge of mold design, manufacturing infrastructure, team work, combination of the project team work, benchmarking, training, clear understanding of project objectives, rewards and motivation, proper management expectation, project management, teamwork and organizational culture. Practical implications: Due to the factors, Top manager can make the best decision for implementing of SMED technique. This study develops factors influencing on SMED implementation based on Shannon and VIKOR methods for ranking parameters and plants.

  8. AN EXPERIMENTAL NOX REDUCTION POTENTIAL INVESTIGATION OF THE PARTIAL HCCI APPLICATION, ON A HIGH PRESSURE FUEL INJECTION EQUIPPED DIESEL ENGINE BY IMPLEMENTING FUMIGATION OF GASOLINE PORT INJECTION

    OpenAIRE

    ERGENÇ, Alp Tekin; YÜKSEK, Levent; ÖZENER, Orkun; IŞIN, Övün

    2016-01-01

    This work investigates the effects of partial HCCI (Homogeneous charge compression ignition) application on today's modern diesel engine tail pipe NOx emissions. Gasoline fumigation is supplied via a port fuel injection system located in the intake port of DI(Direct injection) diesel engine to maintain partial HCCI conditions and also diesel fuel injected directly into the combustion chamber before TDC(Top dead center). A single cylinder direct injection diesel research engine equipped w...

  9. A single intracoronary injection of midkine reduces ischemia/reperfusion injury in swine hearts: a novel therapeutic approach for acute coronary syndrome

    Directory of Open Access Journals (Sweden)

    Hisaaki eIshiguro

    2011-06-01

    Full Text Available Several growth factors are effective for salvaging myocardium and limiting infarct size in experimental studies with small animals. Their benefit in large animals and feasibility in clinical practice remains to be elucidated. We investigate the cardioprotective effect of midkine (MK in swine subjected to ischemia/reperfusion (I/R. I/R was created in swine by left anterior descending coronary artery occlusion for 45 min using a percutaneous over-the-wire balloon catheter. MK protein was injected as a bolus through the catheter at the initiation of reperfusion (midkine injected group; MKT. Saline was injected in controls (CONT. Survival rate 24h after I/R was significantly higher in MKT than in CONT, whereas infarct size/area at risk was almost 5 times smaller. Echocardiography in MKT revealed a significantly higher percent wall thickening of the interventricular septum, a higher % fractional shortening and a lower E/e’ compared with CONT. LV catheterization in MKT showed a lower LVEDP, and a higher dP/dtmax compared with CONT. TUNEL-positive myocytes and CD45-positive cell infiltration in the peri-infarct area were significantly less in MKT than in CONT. Here, we showed that a single intracoronary injection of MK protein in swine hearts at the onset of reperfusion dramatically reduces infarct size and mortality and ameliorates systolic/diastolic LV function. This beneficial effect is associated with a reduction of apoptotic and inflammatory reactions. MK application during percutaneous coronary intervention may become a promising adjunctive therapy in acute coronary syndromes.

  10. Dose-dependent pulmonary response of well-dispersed titanium dioxide nanoparticles following intratracheal instillation

    International Nuclear Information System (INIS)

    Oyabu, Takako; Morimoto, Yasuo; Hirohashi, Masami; Horie, Masanori; Kambara, Tatsunori; Lee, Byeong Woo; Hashiba, Masayoshi; Mizuguchi, Yohei; Myojo, Toshihiko; Kuroda, Etsushi

    2013-01-01

    In order to investigate the relationship between pulmonary inflammation and particle clearance of nanoparticles, and also their dose dependency, we performed an instillation study of well-dispersed TiO 2 nanoparticles and examined the pulmonary inflammations, the particle clearance rate and histopathological changes. Wistar rats were intratracheally administered 0.1 mg (0.33 mg/kg), 0.2 mg (0.66 mg/kg), 1 mg (3.3 mg/kg), and 3 mg (10 mg/kg) of well-dispersed TiO 2 nanoparticles (diameter of agglomerates: 25 nm), and the pulmonary inflammation response and the amount of TiO 2 in the lung were determined from 3 days up to 12 months sequentially after the instillation. There were no increases of total cell or neutrophil counts in bronchoalveolar lavage fluid (BALF) in the 0.1 and the 0.2 mg-administered groups. On the other hand, mild infiltration of neutrophils was observed in the 1 and 3 mg-administered groups. Histopathological findings showed infiltration of neutrophils in the 1 and 3 mg-administered groups. Of special note, a granulomatous lesion including a local accumulation of TiO 2 was observed in the bronchioli-alveolar space in the 3 mg-administered group. The biological half times of the TiO 2 in the lung were 4.2, 4.4, 6.7, and 10.8 months in the 0.1, 0.2, 1, and 3 mg-administered groups, respectively. Neutrophil infiltration was observed as the particle clearance was delayed, suggesting that an excessive dose of TiO 2 nanoparticles may induce pulmonary inflammation and clearance delay.

  11. Single-well injection-withdrawal tests (SWIW). Investigation of evaluation aspects under heterogeneous crystalline bedrock conditions

    International Nuclear Information System (INIS)

    Nordqvist, Rune; Gustafsson, Erik

    2004-08-01

    Single-well injection-withdrawal (SWIW) tracer tests have been identified by SKB as an investigation method for solute transport properties in the forthcoming site investigations. A previous report presents a literature study as well as scoping calculations for SWIW tests in homogeneous crystalline bedrock environments. The present report comprises further scoping calculations under assumptions of heterogeneous bedrock conditions. Simple but plausible homogeneous evaluation models are tested on simulated SWIW tests in hypothetical heterogeneous two-dimensional fractures. The results from this study indicate that heterogeneity may cause effects of flow irreversibility when background hydraulic gradients are significant and the tested section is located in a dominating flow path. This implies that such conditions make it more difficult to interpret results from SWIW tests of longer duration with sorbing and/or diffusing tracers. Sorption and diffusion processes may be best studied when SWIW tests are conducted in borehole sections with low natural flow rates

  12. Bolus injections of measured amounts of radioactivity

    International Nuclear Information System (INIS)

    Wesolowski, C.A.; Hogendoorn, P.; Vandierendonck, R.; Driedger, A.A.

    1988-01-01

    Many time-based radionuclide techniques, such as glomerular filtration rate measurement (GFR), require prompt intravenous delivery of and accurately measured tracer bolus with minimal residual tracer retention at the injection site. The quality assurance aspects of two antecubital vein, quantitative injection techniques were investigated. A flush bolus technique using a tuberculin syringe piggybacked onto a 10-ml saline flush was compared to a single blood pressure cuff injection technique. Scintillation camera data for each technique were compared for bolus duration in the abdominal aorta and for residual activity at the injection site at 5 min. Bolus times were measured as the FWHM of the gamma variate fit to the abdominal aortic regional time-activity curves. Relatively little focal activity was seen in the antecubital injection site following the flush bolus: marked residual activity was seen following the blood pressure cuff injections. The injection site/arm background ratios averaged 1.3 for the flush bolus and 30.1 for the cuff technique. Although both methods allowed accurate in vitro determination of administered radioactivity, only the tuberculin syringe flush bolus technique was acceptable for time-based quantitation because of its superior in vivo characteristics

  13. Systematic assessment of microneedle injection into the mouse cornea

    Directory of Open Access Journals (Sweden)

    Matthaei Mario

    2012-06-01

    Full Text Available Abstract Background Corneal intrastromal injection is an important mode of gene-vector application to subepithelial layers. In a mouse model, this procedure is substantially complicated by the reduced corneal dimensions. Furthermore, it may be difficult to estimate the corneal area reached by the volume of a single injection. This study aimed to investigate intrastromal injections into the mouse cornea using different microneedles and to quantify the effect of injecting varying volumes. A reproducible injection technique is described. Methods Forty eyes of 20 129 Sv/J mice were tested. India ink was intrastromally injected using 30° beveled 33 G needles, tri-surface 25° beveled 35 G needles, or hand-pulled and 25° beveled glass needles. Each eye received a single injection of a volume of 1 or 2 μL. Corneoscleral buttons were fixed and flat mounted for computer-assisted quantification of the affected corneal area. Histological assessment was performed to investigate the intrastromal location of the injected dye. Results A mean corneal area of 5.0 ±1.4 mm2 (mean ± SD and 7.7 ±1.4 mm2 was covered by intrastromal injections of 1 and 2 μL, respectively. The mean percentage of total corneal area reached ranged from 39% to 53% for 1 μL injections, and from 65% to 81% for 2 μL injections. Injections using the 33 G needles tended to provide the highest distribution area. Perforation rates were 8% for 30° beveled 33 G needles and 44% for tri-surface beveled 35 G needles. No perforation was observed with glass needle; however, intrastromal breakage of needle tips was noted in 25% of these cases. Conclusions Intracorneal injection using a 30° beveled 33 G needle was safe and effective. The use of tri-surface beveled 35 G needles substantially increased the number of corneal perforations. Glass needles may break inside the corneal stroma. Injections of 1 μL and 2 μL resulted in an overall mean of 49% and 73% respectively

  14. Spin Injection in Indium Arsenide

    Directory of Open Access Journals (Sweden)

    Mark eJohnson

    2015-08-01

    Full Text Available In a two dimensional electron system (2DES, coherent spin precession of a ballistic spin polarized current, controlled by the Rashba spin orbit interaction, is a remarkable phenomenon that’s been observed only recently. Datta and Das predicted this precession would manifest as an oscillation in the source-drain conductance of the channel in a spin-injected field effect transistor (Spin FET. The indium arsenide single quantum well materials system has proven to be ideal for experimental confirmation. The 2DES carriers have high mobility, low sheet resistance, and high spin orbit interaction. Techniques for electrical injection and detection of spin polarized carriers were developed over the last two decades. Adapting the proposed Spin FET to the Johnson-Silsbee nonlocal geometry was a key to the first experimental demonstration of gate voltage controlled coherent spin precession. More recently, a new technique measured the oscillation as a function of channel length. This article gives an overview of the experimental phenomenology of the spin injection technique. We then review details of the application of the technique to InAs single quantum well (SQW devices. The effective magnetic field associated with Rashba spin-orbit coupling is described, and a heuristic model of coherent spin precession is presented. The two successful empirical demonstrations of the Datta Das conductance oscillation are then described and discussed.

  15. Current Harmonics from Single-Phase Grid-Connected Inverters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2016-01-01

    Environmental conditions and operational modes may significantly impact the distortion level of the injected current from single-phase grid-connected inverter systems, such as photovoltaic (PV) inverters, which may operate in cloudy days with a maximum power point tracking, in a non-unity power...... factor, or in the low voltage ride through mode with reactive current injection. In this paper, the mechanism of the harmonic current injection from grid-connected single-phase inverter systems is thus explored, and the analysis is conducted on single-phase PV systems. In particular, the analysis...... is focused on the impacts of the power factor and the feed-in grid current level on the quality of the feed-in grid current from single-phase inverters. As a consequence, an internal model principle based high performance current control solution is tailor-made and developed for single-phase grid-connected...

  16. Effects of intratracheal instillation of bleomycin on phospholipid synthesis in hamster lung tissue slices

    International Nuclear Information System (INIS)

    Giri, S.N.

    1987-01-01

    Bleomycin, an antineoplastic drug, is known to produce interstitial pulmonary fibrosis (IPF). As a result, it is commonly employed in various species to produce animal models of fibrosis. We have examined the uptake of [ 14 C] acetate by lung slices and its incorporation into lipids in the slices at various times following intratracheal administration of a fibrogenic dose of bleomycin in hamsters. As compared to saline controls, bleomycin had no effect on [ 14 C] acetate uptake at 4 and 7 days but it increased the uptake at 2 and 14 days after treatment. The incorporation of [ 14 C] acetate into total lipid was significantly reduced to 44, 62, 62, and 75% of the control at 2, 4, 7, and 14 days after bleomycin treatment, respectively. The incorporation into lipid as a percentage of the uptake was 12.2 in control animals whereas in bleomycin-treated animals, it was 4.7, 8.0, 7.3, and 6.9 at the corresponding times. Separation of lipids into various fractions revealed that bleomycin treatment specifically inhibited the synthesis of phosphatidylcholine and neutral lipid at all times of the study. The synthesis of all other phospholipids except phosphatidylethanolamine was depressed at 2 days. The latter was, however, depressed at 7 and 14 days after bleomycin treatment. It was concluded from the present study that bleomycin treatment inhibits the synthesis of phospholipid and neutral lipid and this may eventually lead to decreased surfactant production

  17. Rare Case of Intratracheal Metastasis Detected on 68Ga-Prostate-Specific Membrane Antigen PET/CT Scan in a Case of Thyroglobulin Elevated Negative Iodine Scan Syndrome.

    Science.gov (United States)

    Sasikumar, Arun; Joy, Ajith; Pillai, M R A; Oommen, Karuna Elza; Jayakumar, R

    2018-04-01

    A 64-year-old woman underwent completion thyroidectomy with upper tracheal ring resection and right-sided neck dissection for papillary carcinoma of the thyroid infiltrating the trachea and was given I radioiodine treatment. Three years later, she presented with hemoptysis. On evaluation, she had increased serum thyroglobulin and negative iodine scan (TENIS). F-FDG PET/CT scan did not identify any site of disease. One year later, Ga-PSMA scan done revealed a moderate focal tracer-avid intratracheal soft tissue; biopsy revealed it to be metastatic papillary carcinoma of the thyroid. This case kindles the possibility of using Ga-PSMA PET/CT to reveal occult disease in cases of TENIS.

  18. 5.7  W cw single-frequency laser at 671  nm by single-pass second harmonic generation of a 17.2  W injection-locked 1342  nm Nd : YVO4 ring laser using periodically poled MgO : LiNbO3.

    Science.gov (United States)

    Koch, Peter; Ruebel, Felix; Bartschke, Juergen; L'huillier, Johannes A

    2015-11-20

    We demonstrate a continuous wave single-frequency laser at 671.1 nm based on a high-power 888 nm pumped Nd:YVO4 ring laser at 1342.2 nm. Unidirectional operation of the fundamental ring laser is achieved with the injection-locking technique. A Nd:YVO4 microchip laser serves as the injecting seed source, providing a tunable single-frequency power of up to 40 mW. The ring laser emits a single-frequency power of 17.2 W with a Gaussian beam profile and a beam propagation factor of M2beam profile and a beam propagation factor of M2lasers. This work opens possibilities in cold atoms experiments with lithium, allowing the use of larger ensembles in magneto-optical traps or higher diffraction orders in atomic beam interferometers.

  19. Reduction of waveform distortion in grid-injection current from single-phase utility interactive PV-inverter

    International Nuclear Information System (INIS)

    Hamid, Muhammad Imran; Jusoh, Awang

    2014-01-01

    Highlights: • A reduction scheme for harmonics from utility interactive PV-inverter is proposed. • Single-phase conditioner with 3-phase expandability structure is used. • The single-phase conditioner in 3-phase structure work independently. • The scheme works effectively within overall operation range of the PV-inverter. • Conditioner in the scheme also improves the PV-inverter and plant’s utility factor. - Abstract: As the natural behavior of energy source and design characteristic, the current generated by a grid-interactive PV-inverter may contain harmonics. This distortion component will be carried on from the PV-inverter during injection power into the grid. Excessive harmonics in a grid will lead to a variety of power quality problems. This paper presents a distortion reduction scheme, utilizing a fed forward single-phase, generation-side power conditioner with a structure that can be expanded for use in a three-phase system and can work independently under imbalanced condition. Conditioner is placed in parallel with the photovoltaic plant and it functions to compensate the plant’s output current distortion, so that the total current flow to the grid is sinusoidal. This method also includes the implementation of a simpler control system for the conditioner, which consists of a combination of distortion current extraction, synchronization and a current control system, and realized through a TMS320F28335: a 150 MHz floating point DSP controller. Testing of the conditioner prototype, which was conducted on a real operation of a PV plant, showed that the scheme worked effectively within the overall operation range of the PV plant. This paper also discusses the potential of utility factor improvement of the PV-inverter and plant due to implementation of conditioner in the scheme

  20. Performance and combustion analysis of Mahua biodiesel on a single cylinder compression ignition engine using electronic fuel injection system

    Directory of Open Access Journals (Sweden)

    Gunasekaran Anandkumar

    2016-01-01

    Full Text Available In this investigation, experiment is carried out on a 1500 rpm constant speed single cylinder Diesel engine. The test is carried out with Neat diesel, neat biodiesel, and blend B20. The engine considered was run with electronic fuel injection system supported by common rail direct injection to obtain high atomization and effective air utilization inside the combustion chamber. The performance of the engine in terms of break thermal efficiency and brake specific energy consumption was found and compared. The B20 blend shows 1.11% decrease in break thermal efficiency and 3.35% increase in brake specific energy consumption than diesel. The combustion characteristics found are in-cylinder pressure, rate of pressure rise, and heat release rate and compared for peak pressure load to understand the nature of combustion process. For each fuel test run, the maximum peak pressure is observed at part load condition. The rate of change of pressure and heat release rate of diesel is high compared to pure biodiesel and B20 blend. The diffusion combustion is observed to be predominant in case of B100 than B20 and Neat diesel.

  1. Dual fuel injection piggyback controller system

    Science.gov (United States)

    Muji, Siti Zarina Mohd.; Hassanal, Muhammad Amirul Hafeez; Lee, Chua King; Fawzi, Mas; Zulkifli, Fathul Hakim

    2017-09-01

    Dual-fuel injection is an effort to reduce the dependency on diesel and gasoline fuel. Generally, there are two approaches to implement the dual-fuel injection in car system. The first approach is changing the whole injector of the car engine, the consequence is excessive high cost. Alternatively, it also can be achieved by manipulating the system's control signal especially the Electronic Control Unit (ECU) signal. Hence, the study focuses to develop a dual injection timing controller system that likely adopted to control injection time and quantity of compressed natural gas (CNG) and diesel fuel. In this system, Raspberry Pi 3 reacts as main controller unit to receive ECU signal, analyze it and then manipulate its duty cycle to be fed into the Electronic Driver Unit (EDU). The manipulation has changed the duty cycle to two pulses instead of single pulse. A particular pulse mainly used to control injection of diesel fuel and another pulse controls injection of Compressed Natural Gas (CNG). The test indicated promising results that the system can be implemented in the car as piggyback system. This article, which was originally published online on 14 September 2017, contained an error in the acknowledgment section. The corrected acknowledgment appears in the Corrigendum attached to the pdf.

  2. Injection of demineralized bone matrix with bone marrow concentrate improves healing in unicameral bone cyst.

    Science.gov (United States)

    Di Bella, Claudia; Dozza, Barbara; Frisoni, Tommaso; Cevolani, Luca; Donati, Davide

    2010-11-01

    Unicameral bone cysts are benign lesions that usually spontaneously regress with skeletal maturity; however, the high risk of pathologic fractures often justifies treatment that could reinforce a weakened bone cortex. Various treatments have been proposed but there is no consensus regarding the best procedure. We compared the healing rates and failures of two methods of cure based on multiple injections of corticosteroid or a single injection of demineralized bone matrix (DBM) in association with bone marrow concentrate (BMC). We retrospectively reviewed 184 patients who had one of the two treatments for unicameral bone cysts with cortical erosion. Clinical records were reviewed for treatment failures and radiographs for healing in all patients. The minimum followup was 12 months for the Steroids Group (mean, 48 months; range, 12-120 months) and 12 months for the DBM + BMC Group (mean, 20 months; range, 12-28 months). After one treatment we observed a lower healing rate of cysts treated with multiple injections of steroids compared with the healing after the first injection of DBM + BMC (21% versus 58%, respectively). At last followup, 38% healed with steroids and 71% with DBM + BMC. The rate of failure after one steroid injection was higher than after a single injection of BDM + BMC (63% versus 24%, respectively). We observed no difference in fracture rates after treatment between the two groups. A single injection of DBM added with autologous bone marrow concentrate appears to provide a higher healing rate with a lower number of failures compared with a single injection of steroids.

  3. Tritium retention in the femoral bone marrow and spleens of mice receiving single intravenous injections of tritiated water and tritiated thymidine

    International Nuclear Information System (INIS)

    Joshima, Hisamasa; Matsushita, Satoru; Fukutsu, Kumiko; Kashima, Masatoshi

    1987-01-01

    To derive parameters necessary for evaluating the possible hazards of tritium, retention of tritium in total and TCA-insoluble fractions of the femoral marrow and spleen of mice were observed after single intravenous injections of tritiated water and tritiated thymidine. Retention curves of tritium in TCA-insoluble fractions of the femoral marrow and spleen were resolved fairly well into two exponential components. After injecting tritiated thymidine, most of the activity was detected in the TCA-insoluble fraction. Tritium in this fraction decreased with half-times of 2.2 days in the femoral marrow and 3.6 days in the spleen as the first component, and 23.9 days and 30.5 days, respectively, as the second component. After tritiated water injections, the tritium incorporated into the TCA-insoluble fraction was quite small. Most of the activity was considered to be in the TCA-soluble fraction. Tritium in this fraction was estimated to decrease with half-times of 2.6 days in the femoral marrow and 2.3 days in the spleen as the first component, and 8.0 days and 8.2 days, respectively, as the second component. It is concluded that the retention curves of tritium in the bone marrow are similar to those in the spleen for tritiated water, but not for tritiated thymidine. (author)

  4. Diagnosing the PEP-II Injection System

    Energy Technology Data Exchange (ETDEWEB)

    Decker, F.-J.; Donald, M.H.; Iverson, R.H.; Kulikov, A.; Pappas, G.C.; Weaver, M.; /SLAC

    2005-05-09

    The injection of beam into the PEP-II B-Factory, especially into the High Energy Ring (HER) has some challenges. A high background level in the BaBar detector has for a while inhibited us from trickling charge into the HER similar to the Low Energy Ring (LER). Analyzing the injection system has revealed many issues which could be improved. The injection bump between two kickers was not closed, mainly because the phase advance wasn't exactly 180{sup o} and the two kicker strengths were not balanced. Additionally we found reflections which kick the stored beam after the main kick and cause the average luminosity to drop about 3% for a 10 Hz injection rate. The strength of the overall kick is nearly twice as high as the design, indicating a much bigger effective septum thickness. Compared with single beam the background is worse when the HER beam is colliding with the LER beam. This hints that the beam-beam force and the observed vertical blow-up in the HER pushes the beam and especially the injected beam further out to the edge of the dynamic aperture or beyond.

  5. Diagnosing the PEP-II Injection System

    International Nuclear Information System (INIS)

    Decker, F.-J.; Donald, M.H.; Iverson, R.H.; Kulikov, A.; Pappas, G.C.; Weaver, M.; SLAC

    2005-01-01

    The injection of beam into the PEP-II B-Factory, especially into the High Energy Ring (HER) has some challenges. A high background level in the BaBar detector has for a while inhibited us from trickling charge into the HER similar to the Low Energy Ring (LER). Analyzing the injection system has revealed many issues which could be improved. The injection bump between two kickers was not closed, mainly because the phase advance wasn't exactly 180 o and the two kicker strengths were not balanced. Additionally we found reflections which kick the stored beam after the main kick and cause the average luminosity to drop about 3% for a 10 Hz injection rate. The strength of the overall kick is nearly twice as high as the design, indicating a much bigger effective septum thickness. Compared with single beam the background is worse when the HER beam is colliding with the LER beam. This hints that the beam-beam force and the observed vertical blow-up in the HER pushes the beam and especially the injected beam further out to the edge of the dynamic aperture or beyond

  6. Effect of the Ethanol Injection Moment During Compression Stroke on the Combustion of Ethanol - Diesel Dual Direct Injection Engine

    Science.gov (United States)

    Liang, Yu; Zhou, Liying; Huang, Haomin; Xu, Mingfei; Guo, Mei; Chen, Xin

    2018-01-01

    A set of GDI system is installed on a F188 single-cylinder, air-cooled and direct injection diesel engine, which is used for ethanol injection, with the injection time controlled by the crank angle signal collected by AVL angle encoder. The injection of ethanol amounts to half of the thermal equivalent of an original diesel fuel. A 3D combustion model is established for the ethanol - diesel dual direct injection engine. Diesel was injected from the original fuel injection system, with a fuel supply advance angle of 20°CA. The ethanol was injected into the cylinder during compression process. Diesel injection began after the completion of ethanol injection. Ethanol injection starting point of 240°CA, 260°CA, 280°CA, 300°CA and 319.4°CA were simulated and analyzed. Due to the different timing of ethanol injection, the ignition of the ethanol mixture when diesel fires, results in non-uniform ignition distribution and flame propagation rate, since the distribution and concentration gradients of the ethanol mixture in the cylinder are different, thus affecting the combustion process. The results show that, when ethanol is injected at 319.4°CA, the combustion heat release rate and the pressure rise rate during the initial stage are the highest. Also, the maximum combustion pressure, with a relatively advance phase, is the highest. In case of later initial ethanol injection, the average temperature in the cylinder during the initial combustion period will have a faster rise. In case of initial injection at 319.4°CA, the average temperature in the cylinder is the highest, followed by 240°CA ethanol injection. In the post-combustion stage, the earlier ethanol injection will result in higher average temperature in the cylinder and more complete fuel combustion. The injection of ethanol at 319.4°CA produces earlier and highest NOX emissions.

  7. Cylinder Pressure-based Combustion Control with Multi-pulse Fuel Injection

    NARCIS (Netherlands)

    Luo, X.; Wang, S.; Jager, B. de; Willems, F.P.T.

    2015-01-01

    With an increased number of fuel injection pulses, the control problem in diesel engines becomes complex. Consisting of multiple single-input single-output (SISO) controllers, the conventional control strategy shows unsatisfactory dynamic performance in tracking combustion load and phase reference

  8. Dose-dependent pulmonary response of well-dispersed titanium dioxide nanoparticles following intratracheal instillation

    Energy Technology Data Exchange (ETDEWEB)

    Oyabu, Takako [Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Department of Environmental Health Engineering (Japan); Morimoto, Yasuo, E-mail: yasuom@med.uoeh-u.ac.jp; Hirohashi, Masami; Horie, Masanori; Kambara, Tatsunori [Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Department of Occupational Pneumology (Japan); Lee, Byeong Woo [Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Department of Environmental Health Engineering (Japan); Hashiba, Masayoshi [Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Department of Occupational Pneumology (Japan); Mizuguchi, Yohei; Myojo, Toshihiko [Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Department of Environmental Health Engineering (Japan); Kuroda, Etsushi [Osaka University, Laboratory of Vaccine Science, WPI Immunology Frontier Research Center (Japan)

    2013-04-15

    In order to investigate the relationship between pulmonary inflammation and particle clearance of nanoparticles, and also their dose dependency, we performed an instillation study of well-dispersed TiO{sub 2} nanoparticles and examined the pulmonary inflammations, the particle clearance rate and histopathological changes. Wistar rats were intratracheally administered 0.1 mg (0.33 mg/kg), 0.2 mg (0.66 mg/kg), 1 mg (3.3 mg/kg), and 3 mg (10 mg/kg) of well-dispersed TiO{sub 2} nanoparticles (diameter of agglomerates: 25 nm), and the pulmonary inflammation response and the amount of TiO{sub 2} in the lung were determined from 3 days up to 12 months sequentially after the instillation. There were no increases of total cell or neutrophil counts in bronchoalveolar lavage fluid (BALF) in the 0.1 and the 0.2 mg-administered groups. On the other hand, mild infiltration of neutrophils was observed in the 1 and 3 mg-administered groups. Histopathological findings showed infiltration of neutrophils in the 1 and 3 mg-administered groups. Of special note, a granulomatous lesion including a local accumulation of TiO{sub 2} was observed in the bronchioli-alveolar space in the 3 mg-administered group. The biological half times of the TiO{sub 2} in the lung were 4.2, 4.4, 6.7, and 10.8 months in the 0.1, 0.2, 1, and 3 mg-administered groups, respectively. Neutrophil infiltration was observed as the particle clearance was delayed, suggesting that an excessive dose of TiO{sub 2} nanoparticles may induce pulmonary inflammation and clearance delay.

  9. The biological effects of 224Ra injected into dogs

    International Nuclear Information System (INIS)

    Muggenburg, B.A.; Lloyd, R.D.; Hahn, F.F.; Griffith, W.C.; Boecker, B.B.

    1994-01-01

    The purpose of this study was to investigate the toxicity of injected 224 Ra in the dog. Radium-224 is a short-lived isotope of radium with a half-life of 3.62 d. When administered parenterally, it deposits on bone surfaces; because of its short half-life, most of its energy is deposited on bone surfaces, in a manner similar to plutonium. The experimental design included a comparison to the exposed human population. Instead of using a single injection of 224 Ra, groups were included in which dogs were injected once, 10 times, or 50 times. This design provided groups that could be compared to the multiple injections often used in people for the treatment of ankylosing spondylitis

  10. Experimental optimization of a direct injection homogeneous charge compression ignition gasoline engine using split injections with fully automated microgenetic algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Canakci, M. [Kocaeli Univ., Izmit (Turkey); Reitz, R.D. [Wisconsin Univ., Dept. of Mechanical Engineering, Madison, WI (United States)

    2003-03-01

    Homogeneous charge compression ignition (HCCI) is receiving attention as a new low-emission engine concept. Little is known about the optimal operating conditions for this engine operation mode. Combustion under homogeneous, low equivalence ratio conditions results in modest temperature combustion products, containing very low concentrations of NO{sub x} and particulate matter (PM) as well as providing high thermal efficiency. However, this combustion mode can produce higher HC and CO emissions than those of conventional engines. An electronically controlled Caterpillar single-cylinder oil test engine (SCOTE), originally designed for heavy-duty diesel applications, was converted to an HCCI direct injection (DI) gasoline engine. The engine features an electronically controlled low-pressure direct injection gasoline (DI-G) injector with a 60 deg spray angle that is capable of multiple injections. The use of double injection was explored for emission control and the engine was optimized using fully automated experiments and a microgenetic algorithm optimization code. The variables changed during the optimization include the intake air temperature, start of injection timing and the split injection parameters (per cent mass of fuel in each injection, dwell between the pulses). The engine performance and emissions were determined at 700 r/min with a constant fuel flowrate at 10 MPa fuel injection pressure. The results show that significant emissions reductions are possible with the use of optimal injection strategies. (Author)

  11. Intra-Articular, Single-Shot Hylan G-F 20 Hyaluronic Acid Injection Compared with Corticosteroid in Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Kanitnate, Supakit; Yakumpor, Thanasak; Panichkul, Phonthakorn

    2016-06-01

    The treatment of knee osteoarthritis with hyaluronic acid or corticosteroid injection has been widely used. The purpose of this study was to compare the efficacy of hyaluronic acid (hylan G-F 20) with triamcinolone acetonide as a single intra-articular injection for knee osteoarthritis. This study was a prospective, randomized, double-blind clinical trial. Participants with symptomatic knee osteoarthritis were recruited. They were randomized to receive a single-shot, intra-articular injection of either 6 mL of hylan G-F 20 or 6 mL of a solution comprising 1 mL of 40-mg triamcinolone acetonide and 5 mL of 1% lidocaine with epinephrine. The primary outcomes were knee pain severity, knee function, and range of motion at 6 months. Ninety-nine patients were assessed before injection and underwent a 6-month follow-up. Patients and evaluators were blinded. Multilevel regression models were used to estimate differences between the groups. At the 6-month follow-up, compared with patients who took hylan G-F 20, patients who took triamcinolone acetonide had similar improvement in knee pain, knee function, and range of motion. The difference in mean outcome scores between groups was, with regard to knee pain, a visual analog scale (VAS) score of 3 points (95% confidence interval [95% CI], -6 to 11 points); with regard to knee function, a modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score of 0 points (95% CI, -8 to 6 points); and, with regard to range of motion, flexion of -1° (95% CI, -5° to 2°) and extension of 0° (95% CI, -0.5° to 0.5°). However, patients who took triamcinolone acetonide had better pain improvement from 24 hours until 1 week after injection; the mean difference between groups with regard to the VAS score was 12 points (95% CI, 5 to 20 points; p = 0.002) at 24 hours and 9 points (95% CI, 1 to 15 points; p = 0.018) at 1 week. At 2 weeks after injection, patients who took triamcinolone acetonide also had better knee

  12. Intravitreal injection of perfluoropropane for the treatment of vitreomacular traction

    Directory of Open Access Journals (Sweden)

    Xiao-Ping Wan

    2013-07-01

    Full Text Available AIM: To study the efficacy of a single intravitreal injection of perfluoropropane(C3F8in releasing vitreomacular traction. METHODS: Twelve eyes of 12 consecutive patients with vitreomacular traction received a single intravitreal injection of 0.3mL 100%(C3F8were retrospectively analyzed. The best corrected vision acuity and the neural epithelium thickness of central macular were observed. RESULTS: One month following treatment, vitreomacular traction was released in 5 eyes(42%, mean final visual acuity(VAimproved 0.04 and mean central foveal thickness decreased by 69μm. The vision acuity before and after treatment were 0.20±0.07, 0.25±0.04 respectively.CONCLUSION: Intravitreal C3F8 injection could offer a minimally invasive alternative to pars plana vitrectomy in patients with vitreomacular traction.

  13. Spin injection into a two-dimensional electron gas using inter-digital-ferromagnetic contacts

    DEFF Research Database (Denmark)

    Hu, C.M.; Nitta, J.; Jensen, Ane

    2002-01-01

    We present a model that describes the spin injection across a single interface with two electrodes. The spin-injection rate across a typical hybrid junction made of ferromagnet (FM) and a two-dimensional electron gas (2DEG) is found at the percentage level. We perforin spin-injection-detection ex......-injection-detection experiment on devices with two ferromagnetic contacts on a 2DEG confined in an InAs quantum well. A spin-injection rate of 4.5% is estimated from the measured magnetoresistance....

  14. Quantitative analysis of fragrance in selectable one dimensional or two dimensional gas chromatography-mass spectrometry with simultaneous detection of multiple detectors in single injection.

    Science.gov (United States)

    Tan, Hui Peng; Wan, Tow Shi; Min, Christina Liew Shu; Osborne, Murray; Ng, Khim Hui

    2014-03-14

    A selectable one-dimensional ((1)D) or two-dimensional ((2)D) gas chromatography-mass spectrometry (GC-MS) system coupled with flame ionization detector (FID) and olfactory detection port (ODP) was employed in this study to analyze perfume oil and fragrance in shower gel. A split/splitless (SSL) injector and a programmable temperature vaporization (PTV) injector are connected via a 2-way splitter of capillary flow technology (CFT) in this selectable (1)D/(2)D GC-MS/FID/ODP system to facilitate liquid sample injections and thermal desorption (TD) for stir bar sorptive extraction (SBSE) technique, respectively. The dual-linked injectors set-up enable the use of two different injector ports (one at a time) in single sequence run without having to relocate the (1)D capillary column from one inlet to another. Target analytes were separated in (1)D GC-MS/FID/ODP and followed by further separation of co-elution mixture from (1)D in (2)D GC-MS/FID/ODP in single injection without any instrumental reconfiguration. A (1)D/(2)D quantitative analysis method was developed and validated for its repeatability - tR; calculated linear retention indices (LRI); response ratio in both MS and FID signal, limit of detection (LOD), limit of quantitation (LOQ), as well as linearity over a concentration range. The method was successfully applied in quantitative analysis of perfume solution at different concentration level (RSD≤0.01%, n=5) and shower gel spiked with perfume at different dosages (RSD≤0.04%, n=5) with good recovery (96-103% for SSL injection; 94-107% for stir bar sorptive extraction-thermal desorption (SBSE-TD). Copyright © 2014 Elsevier B.V. All rights reserved.

  15. [Study and development of a new automatic suction system (SS) of intratracheal sputum in order to improve QOL of many patients with tracheostomy mechanical ventilation (TMV) and their family members by this new autonomic SS].

    Science.gov (United States)

    Hokezu, Youichi; Yamamoto, Makoto; Tokunaga, Syuichi; Niikura, Makoto; Nagamatsu, Keiji; Kira, Jun-ichi; Fukunaga, Toshihide; Shima, Kouji; Kikuchi, Seiji; Kimura, Itaru; Kondo, Kiyohiko; Mori, Teruhiko; Goto, Katumasa; Takigami, Shigeru; Shioya, Keiichi; Uehara, Minako

    2009-11-01

    In Japan, many patients equipped with TMV are under medical treatment at home after 1990. These patients can't put out sputa in trachea, so that these patient's family members must suck these patient's intratracheal sputa all days. Mr Yamamoto and Mr Tokunaga, main researchers of this study, began the study on the automatic SS of itratracheal sputa from 1999. In first stage, They developed the intermittent SS in detaining the suction tube within tracheal cannula, monitering the intratracheal pressure, but this system takes the ventilation away from the patient. Hypoventilation caused by this SS may cause the serious accident in patient. Therefore, we remodel the SS from intermittent SS to rollerpomp-type SS continuing to suck the itratracheal sputa with low volume from 2004, and thereafter we made up the SS of piston pomp type-SS finally at 2007. We developed the tracheal cannula with double suction holes of inner and lower hole in the lower part of its cannula together with the suction machine. We think that the practical use of this automatic SS will bring these patients with TMV and their family members great benefits. We desire that the practical use of this SS will be realized as soon as possible.

  16. Calculation of injection and extraction orbits for the IPCR SSC

    International Nuclear Information System (INIS)

    Goto, A.; Yano, Y.; Kishida, N.; Nakanishi, N.; Wada, T.

    1982-01-01

    Calculations of beam trajectories in the injection and extraction systems for the IPCR SSC were done and the characteristics of those elements were determined. Beam centering for single turn extraction by use of first harmonic fields were also studied. The rather simple conditions at the injection point for a well-centered acceleration orbit are also discussed

  17. Synchronization of skin ablation and microjet injection for an effective transdermal drug delivery

    Science.gov (United States)

    Jang, Hun-jae; Yeo, Seonggu; Yoh, Jack J.

    2016-04-01

    An Er:YAG laser with 2940-nm wavelength and 150-µs pulse duration was built for the purpose of combined ablation and microjet injection. A shorter pulse duration compared to common erbium lasers in dentistry is desirable for a synchronization of skin ablation and subsequent microjet injection into target skin for transdermal injection of liquid dose. A single laser beam is split into two for an optimal energy of pre-ablation of skin and the residual energy allocated to a microjet ejection. A newly designed injector consists of an L-shaped chamber and a parabolic mirror in a single unit, and the handheld laser is a part of an integrated system requiring no optical fiber. Through various injection tests using the porcine skin, the effectiveness of the new delivery system is herein evaluated.

  18. An Optical Method for Measuring Injection Timing in Diesel Engines, Using a Single Port

    Science.gov (United States)

    2014-09-01

    injection, naturally aspirated marine diesel engine with mechanical unit injectors and showed satisfactory results with blends ranging from 25% HRD/75... injector technology, they further concluded that the mechanical unit injectors found throughout the naval fleet and on the Detroit Diesel 3–53 in the...injection timing in a pump-line- nozzle system of blending Fischer- Tropsch derived diesel fuel with low sulfur, ultra-low sulfur and biodiesel fuels. The

  19. Injection system of compact SR light source 'AURORA'

    International Nuclear Information System (INIS)

    Takayama, Takeshi; Yano, Takashi; Sasaki, Yasushi; Yasumitsu, Naoki

    1991-01-01

    A half-integer-resonance injection method is introduced for a superconducting SR-ring of 1 m orbit diameter, which is made of a weak focussing single-body magnet. The present method makes it possible to inject an electron beam of an energy of as high as 150 MeV into the ring of a magnetic field strength of 1 T. Several new injection devices are introduced in order to guide the beam under the strong magnetic fringing field, and to excite the half-integer-resonance. The field index of 0.73 is selected for the half-integer-resonance injection. The field index of 0.35 at the maximum magnetic field strength of 4.3 T is to get a sufficiently long quantum lifetime. A new device named resonance jumper is used to pass quickly several resonances of betatron motion without beam loss. The resonances occur when the magnetic field is ramped up and the field index decreases from 0.73 to 0.35. The injection devices except the inflector are air-core magnets in order to work in the strong magnetic field. In November of 1989, the beam was successfully injected and stored. The injection devices and the half-integer-resonance injection method were established. (author)

  20. Pharmacokinetic/Pharmacodynamic Profiles of Tiamulin in an Experimental Intratracheal Infection Model of Mycoplasma gallisepticum.

    Science.gov (United States)

    Xiao, Xia; Sun, Jian; Yang, Tao; Fang, Xi; Cheng, Jie; Xiong, Yan Q; Liu, Ya-Hong

    2016-01-01

    Mycoplasma gallisepticum is the most important pathogen in poultry among four pathogenic Mycoplasma species. Tiamulin is a pleuromutilin antibiotic that shows a great activity against M. gallisepticum and has been approved for use in veterinary medicine particularly for poultry. However, the pharmacokinetic/pharmacodynamics (PK/PD) profiles of tiamulin against M. gallisepticum are not well understood. Therefore, in the current studies, we investigated the in vivo PK/PD profiles of tiamulin using a well-established experimental intratracheal infection model of M. gallisepticum. The efficacy of tiamulin against M. gallisepticum was studied in 8-day-old chickens after intramuscular (i.m.) administration at 10 doses between 0-80 mg/kg. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used to evaluate the PK parameters of tiamulin following i.m. administration at doses of 5, 40, and 80 mg/kg in Mycoplasma gallisepticum-infected neutropenic chickens. Real-time PCR (RT-PCR) was used for quantitative detection of M. gallisepticum. The MIC of tiamulin against M. gallisepticum strain S6 was 0.03 μg/mL. The PK/PD index, AUC24h/MIC, correlated well with the in vivo antibacterial efficacy. The in vivo data suggest that animal dosage regimens should supply AUC24h/MIC of tiamulin of 382.68 h for 2 log10 ccu equivalents M. gallisepticum reduction. To attain that goal, the administered dose is expected to be 45 mg/kg b.w. for treatment of M. gallisepticum infection with an MIC90 of 0.03 μg/mL.

  1. Pharmacokinetic/Pharmacodynamic Profiles of Tiamulin in an Experimental Intratracheal Infection Model of Mycoplasma gallisepticum

    Directory of Open Access Journals (Sweden)

    Xia Xiao

    2016-09-01

    Full Text Available Mycoplasma gallisepticum is the most important pathogen in poultry among four pathogenic Mycoplasma species. Tiamulin is a pleuromutilin antibiotic that shows a great activity against M. gallisepticum and has been approved for use in veterinary medicine particularly for poultry. However, the Pharmacokinetic/Pharmacodynamics (PK/PD profiles of tiamulin against M. gallisepticum are not well understood. Therefore, in the current studies, we investigated the in vivo PK/PD profiles of tiamulin using a well-established experimental intratracheal infection model of M. gallisepticum. The efficacy of tiamulin against M. gallisepticum was studied in 8-day-old chickens after intramuscular (i.m. administration at 10 doses between 0-80 mg/kg. Liquid chromatography-tandem mass spectrometry (LC-MS/MS was used to evaluate the PK parameters of tiamulin following i.m. administration at doses of 5, 40 and 80 mg/kg in Mycoplasma gallisepticum infected neutropenic chickens. Real time PCR (RT-PCR was used for quantitative detection of M. gallisepticum. The MIC of tiamulin against M. gallisepticum strain S6 was 0.03 μg/mL. The PK/PD index, AUC24h/MIC, correlated well with the in vivo antibacterial efficacy. The in vivo data suggest that animal dosage regimens should supply AUC24h/MIC of tiamulin of 382.68 h for 2 log10 ccu equivalents M. gallisepticum reduction. To attain that goal, the administered dose is expected to be 45 mg/kg b.w. for treatment of M. gallisepticum infection with an MIC90 of 0.03 μg/mL.

  2. Intratracheal infection as an efficient route for testing vaccines against Chlamydia abortus in sheep.

    Science.gov (United States)

    Álvarez, D; Salinas, J; Buendía, A J; Ortega, N; del Río, L; Sánchez, J; Navarro, J A; Gallego, M C; Murcia-Belmonte, A; Cuello, F; Caro, M R

    2015-09-01

    Pregnant ewes have been widely used to test vaccines against Chlamydia abortus. However, this model entails many disadvantages such as high economic costs and long periods of pregnancy. The murine model is very useful for specific studies but cannot replace the natural host for the later stages of vaccine evaluation. Therefore, a non-pregnant model of the natural host might be useful for a vaccine trial to select the best vaccine candidates prior to use of the pregnant model. With this aim, two routes of infection were assessed in young non-pregnant sheep, namely, intranasal (IN) and intratracheal (IT). In addition, groups of non-vaccinated sheep and sheep immunised with an inactivated vaccine were established to investigate the suitability of the model for testing vaccines. After the experimental infection, isolation of the microorganism in several organs, with pathological and immunohistochemical analyses, antibody production assessment and investigation by PCR of the presence of chlamydia in the vagina or rectum were carried out. Experimental IT inoculation of C. abortus induced pneumonia in sheep during the first few days post-infection, confirming the suitability of the IT route for testing vaccines in the natural host. The course of infection and the resulting pathological signs were less severe in vaccinated sheep compared with non-vaccinated animals, demonstrating the success of vaccination. IN infection did not produce evident lesions or demonstrate the presence of chlamydial antigen in the lungs and cannot be considered an appropriate model for testing vaccines. Copyright © 2015 Elsevier Ltd. All rights reserved.

  3. Dimensional accuracy of Acrylonitrile Butadiene Styrene injection molded parts produced in a pilot produc

    DEFF Research Database (Denmark)

    Mischkot, Michael; Davoudinejad, Ali; Charalambis, Alessandro

    of a geometry including micro-features have been injection-molded in Acrylonitrile Butadiene Styrene (ABS) with a single 20x20x2.5 mm^3 injection molding insert manufactured in a photopolymer composite material. This research investigates the dimensional accuracy of the injection molded parts as a function...

  4. Evaluation of acute toxicity and the effect of single injected doses of ...

    African Journals Online (AJOL)

    USER

    2010-07-12

    Jul 12, 2010 ... significant in therapeutic applications against diseases of diverse origins .... The rats were killed under ether anesthesia; one hour after injection and blood ..... that zerumbone could be safe for use in one dose treatment.

  5. Clinical and instrumental evaluation of a cross-linked hyaluronic acid filler dermal injection: effects on nasolabial folds skin biophysical parameters and augmentation from a single-dose, monocentric, open-label trial.

    Science.gov (United States)

    Cameli, Norma; Mariano, Maria; Serio, Mirko; Berardesca, Enzo

    2016-10-01

    When a hyaluronic acid dermal device to fill soft tissues is chosen, efficacy, safety and durability are key concerns. This is an open-label prospective study to instrumentally evaluate the effects of HA filler dermal injection on nasolabial folds skin biophysical parameters and augmentation. A single Italian site treated female subjects aged 40-55, for nasolabial folds, with a single standardized injection. The outcome was evaluated with objective quantitative measurements after 90 (T1) and 180 days (T2) from the injection comparing to baseline (T0) by means of Corneometer (skin hydration measurement), Cutometer (skin elasticity measurement), and Visioface devices for digital and UV computerized image analysis. Secondary endpoints were safety assessment, subject investigator satisfaction with the intervention. Assessment of aesthetic results included photographic documentation. The computerized image analysis confirmed the clinical assessment showing statistically significant reduction in nasolabial folds both at T1 and T2. Visioface® indexes showed a marked and statistical significant response. An excellent profile of satisfaction of the product at T2 from investigators and patients was recorded. Skin hydration and elasticity did not show significant changes. In our study, a standardized HA filler dermal injection on nasolabial folds did not influence skin biophysical parameters such as skin hydration and elasticity. Nasolabial folds showed a persistent and significative response at T2 confirmed by instrumental evaluation. The tolerability and safety profile of the product was excellent.

  6. Effect of Pilot Injection Timings on the Combustion Temperature Distribution in a Single-Cylinder CI Engine Fueled with DME and ULSD

    Directory of Open Access Journals (Sweden)

    Jeon Joonho

    2016-01-01

    Full Text Available Many studies of DiMethyl Ether (DME as an alternative fuel in Compression-Ignition (CI engines have been performed. Although diverse DME engine research has been conducted, the investigation of combustion behavior and temperature distribution in the combustion engine has not progressed due to the fact that there is no sooting flame in DME combustion. In order to investigate the combustion characteristics in this study, the KIVA-3 V code was implemented to research various pilot injection strategies on a single-cylinder CI engines with DME and Ultra-Low-Sulfur Diesel (ULSD fuels. The combustion distribution results obtained from the numerical investigation were validated when compared with the measurement of flame temperature behaviors in the experimental approach. This study showed that long intervals between two injection timings enhanced pilot combustion by increasing the ambient pressure and temperature before the start of the main combustion. Different atomization properties between DME and ULSD fuels contributed to the formation of a fuel-air mixture at the nozzle tip and piston lip regions, separately, which strongly affected the temperature distribution of the two fuels. In addition, the pilot injection timing played a vital role in regard to ignition delay and peak combustion temperatures. Exhaust emissions, such as NOx and soot, are related to the local equivalence ratio and temperature in the combustion chamber, also illustrated by the contrary result on a Φ (equivalence ratio – T (temperature map.

  7. Intratracheal Bleomycin Aerosolization: The Best Route of Administration for a Scalable and Homogeneous Pulmonary Fibrosis Rat Model?

    Directory of Open Access Journals (Sweden)

    Alexandre Robbe

    2015-01-01

    Full Text Available Idiopathic pulmonary fibrosis (IPF is a chronic disease with a poor prognosis and is characterized by the accumulation of fibrotic tissue in lungs resulting from a dysfunction in the healing process. In humans, the pathological process is patchy and temporally heterogeneous and the exact mechanisms remain poorly understood. Different animal models were thus developed. Among these, intratracheal administration of bleomycin (BML is one of the most frequently used methods to induce lung fibrosis in rodents. In the present study, we first characterized histologically the time-course of lung alteration in rats submitted to BLM instillation. Heterogeneous damages were observed among lungs, consisting in an inflammatory phase at early time-points. It was followed by a transition to a fibrotic state characterized by an increased myofibroblast number and collagen accumulation. We then compared instillation and aerosolization routes of BLM administration. The fibrotic process was studied in each pulmonary lobe using a modified Ashcroft scale. The two quantification methods were confronted and the interobserver variability evaluated. Both methods induced fibrosis development as demonstrated by a similar progression of the highest modified Ashcroft score. However, we highlighted that aerosolization allows a more homogeneous distribution of lesions among lungs, with a persistence of higher grade damages upon time.

  8. Intratracheally instilled titanium dioxide nanoparticles translocate to heart and liver and activate complement cascade in the heart of C57BL/6 mice

    DEFF Research Database (Denmark)

    Husain, Mainul; Wu, Dongmei; Saber, Anne T.

    2015-01-01

    translocation from the lungs. Adult female C57BL/6 mice were exposed via intratracheal instillation to 18 or 162 mu g of industrially relevant titanium dioxide nanoparticles (nano-TiO2) alongside vehicle controls. Using the nano-scale hyperspectral microscope, translocation to heart and liver was confirmed...... of translocation are unclear. We employed a nano-scale hyperspectral microscope to spatially observe and spectrally profile NPs in tissues and blood following pulmonary deposition in mice. In addition, we characterized effects occurring in blood, liver and heart at the mRNA and protein level following...... at both doses, and to blood at the highest dose, in mice analyzed 24 h post-exposure. Global gene expression profiling and ELISA analysis revealed activation of complement cascade and inflammatory processes in heart and specific activation of complement factor 3 in blood, suggesting activation of an early...

  9. Electrically Injected UV-Visible Nanowire Lasers

    Energy Technology Data Exchange (ETDEWEB)

    Wang, George T.; Li, Changyi; Li, Qiming; Liu, Sheng; Wright, Jeremy Benjamin; Brener, Igal; Luk, Ting -Shan; Chow, Weng W.; Leung, Benjamin; Figiel, Jeffrey J.; Koleske, Daniel D.; Lu, Tzu-Ming

    2015-09-01

    There is strong interest in minimizing the volume of lasers to enable ultracompact, low-power, coherent light sources. Nanowires represent an ideal candidate for such nanolasers as stand-alone optical cavities and gain media, and optically pumped nanowire lasing has been demonstrated in several semiconductor systems. Electrically injected nanowire lasers are needed to realize actual working devices but have been elusive due to limitations of current methods to address the requirement for nanowire device heterostructures with high material quality, controlled doping and geometry, low optical loss, and efficient carrier injection. In this project we proposed to demonstrate electrically injected single nanowire lasers emitting in the important UV to visible wavelengths. Our approach to simultaneously address these challenges is based on high quality III-nitride nanowire device heterostructures with precisely controlled geometries and strong gain and mode confinement to minimize lasing thresholds, enabled by a unique top-down nanowire fabrication technique.

  10. Pulmonary exposure to particles from diesel exhaust, urban dust or single-walled carbon nanotubes and oxidatively damaged DNA and vascular function in apoE(-/-)mice

    DEFF Research Database (Denmark)

    Vesterdal, Lise K; Jantzen, Kim; Sheykhzade, Majid

    2012-01-01

    Abstract This study compared the oxidative stress level and vasomotor dysfunction after exposure to urban dust, diesel exhaust particles (DEP) or single-walled carbon nanotubes (SWCNT). DEP and SWCNT increased the production of reactive oxygen species (ROS) in cultured endothelial cells and acell......Abstract This study compared the oxidative stress level and vasomotor dysfunction after exposure to urban dust, diesel exhaust particles (DEP) or single-walled carbon nanotubes (SWCNT). DEP and SWCNT increased the production of reactive oxygen species (ROS) in cultured endothelial cells...... and acellullarly, whereas the exposure to urban dust did not generate ROS. ApoE(-/-) mice, which were exposed twice to 0.5 mg/kg of the particles by intratracheal instillation, had unaltered acetylcholine-elicited vasorelaxation in aorta segments. There was unaltered pulmonary expression level of Vcam-1, Icam-1...

  11. Low energy, high power injection in JT-60 NBI

    International Nuclear Information System (INIS)

    Mizuno, Makoto; Dairaku, Masayuki; Horiike, Hiroshi

    1988-05-01

    JT-60 neutral beam injector (JT-60 NBI) is designed to inject 20 MW neutral hydrogen beam at energies of 70 ∼ 100 keV and the injection power decreases significantly at low energies (∼40 keV). For the extention of operation region aiming at the low density plasma heating and achieving H-mode by plasma periphery heating, increment of the injection power at low beam energies was required. The single-stage acceleration system was investigated in advance at the Prototype Injector Unit. From this result, the total injection power of 17 MW at 40 keV, 48 A per source was expected at the JT-60 NBI. This system was adopted in the JT-60 NBI from June, 1987 to July, 1987 and 17.6 MW neutral beam injection power was achieved. In the NB heating experiment, the H-mode transition phenomena was observed in JT-60 plasma. (author)

  12. Comparative in Vivo Assessment of Some Adverse Bioeffects of Equidimensional Gold and Silver Nanoparticles and the Attenuation of Nanosilver’s Effects with a Complex of Innocuous Bioprotectors

    Directory of Open Access Journals (Sweden)

    Boris A. Katsnelson

    2013-01-01

    Full Text Available Stable suspensions of nanogold (NG and nanosilver (NS with mean particle diameter 50 and 49 nm, respectively, were prepared by laser ablation of metals in water. To assess rat’s pulmonary phagocytosis response to a single intratracheal instillation of these suspensions, we used optical, transmission electron, and semi-contact atomic force microscopy. NG and NS were also repeatedly injected intraperitoneally into rats at a dose of 10 mg/kg (0.5 mg per mL of deionized water three times a week, up to 20 injections. A group of rats was thus injected with NS after oral administration of a “bioprotective complex” (BPC comprised of pectin, multivitamins, some amino acids, calcium, selenium, and omega-3 PUFA. After the termination of the injections, many functional and biochemical indices and histopathological features of the spleen, kidneys and liver were evaluated for signs of toxicity, and accumulation of NG or NS in these organs was measured. From the same rats, we obtained cell suspensions of different tissues for performing the RAPD test. It was demonstrated that, although both nanometals were adversely bioactive in all respects considered in this study, NS was more noxious as compared with NG, and that the BPC tested by us attenuated both the toxicity and genotoxicity of NS.

  13. Mycobacterium massiliense outbreak after intramuscular injection, South Korea.

    Science.gov (United States)

    Kim, H J; Cho, Y; Lee, S; Kook, Y; Lee, D; Lee, J; Park, B J

    2012-10-01

    SUMMARY We conducted an epidemic investigation to discover the route of transmission and the host factors of an outbreak of post-injection abscesses. Of the 2984 patients who visited a single clinic, 77 cases were identified and 208 age- and sex-matched controls were selected for analysis. Injected medications per se were not found to be responsible, and a deviation from safe injection practice suggested the likelihood of diluent contamination. Therefore the injected medications were classified according to whether there was a need for a diluent, and two medications showed a statistically significant association, i.e. injection with pheniramine [adjusted odds ratios (aOR) 5·93, 95% confidence interval (CI) 2·97-11·87] and ribostamycin (aOR 47·95, 95% CI 11·08-207·53). However, when considered concurrently, pheniramine lost statistical significance (aOR 8·71, 95% CI 0·44-171·61) suggesting that normal saline was the causative agent of this outbreak. Epidemiological evidence strongly suggested that this post-injection outbreak was caused by saline contaminated with Mycobacterium massiliense without direct microbiological evidence.

  14. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    International Nuclear Information System (INIS)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S.

    2015-01-01

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  15. Design and development of the helicity injection system in Versatile Experiment Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Park, JongYoon; An, Younghwa; Jung, Bongki; Lee, Jeongwon; Lee, HyunYoung; Chung, Kyoung-Jae; Na, Yong-Su; Hwang, Y.S., E-mail: yhwang@snu.ac.kr

    2015-10-15

    Graphical abstract: - Highlights: • A high current electron gun with single pulse power for both arc and extraction is developed. • The optimal gun operation is confirmed by impedance matching between the PFN and plasma. • The gun injected currents of 0.95 kA with the voltage of ∼410 V for 5 ms with a 1.2 kV PFN. • The helicity injection system using the gun has been developed and tested successfully in VEST. • Toroidal currents of up to 3.8 kA confirm possible relaxation into tokamak-like plasma. - Abstract: A helicity injection system for the Versatile Experiment Spherical Torus (VEST) has been successfully developed and commissioned. A high current electron gun utilizing hollow cathode and washer stacks has been designed and constructed with a single pulse power system that can provide voltages for both arc discharge and extraction sequentially. Tests for electron gun operation with the single pulse power system have been conducted under various toroidal and poloidal field strengths. The estimated plasma impedance, depending on the injection magnetic field structure, can be utilized for the optimal gun operation by impedance matching between the pulse power system and plasma. With the charging voltage of 1.2 kV, injection current of 0.95 kA has been obtained with the injection voltage of 410 V for about 5 ms. Initial helicity injection experiments have been conducted under various toroidal and poloidal field strengths and a toroidal plasma current of up to 3.8 kA is observed with the current multiplication larger than the geometric stacking ratio, confirming the possibility of relaxation into tokamak-like plasma with closed flux formation.

  16. Clinical effectiveness of multiple-drug injection treatment in unruptured ectopic pregnancies: a retrospective study.

    Science.gov (United States)

    Dai, Quan; Wang, Lu-Lu; Shao, Xiao-Hui; Wang, Si-Ming; Dong, Xiao-Qiu

    2012-10-01

    To study the effect of local interventional treatment of unruptured ectopic pregnancies with multiple-drug injection guided by color Doppler sonography. In this retrospective analysis, 49 patients with an unruptured ectopic pregnancy were treated with two different local injection methods administered under sonographic guidance. The patients were divided into single-drug (n = 23) and multiple-drug (n = 26) injection groups, and they received a locally administered injection of methotrexate alone or a combination including methotrexate, hemocoagulase, antibiotics, and anti-inflammatory drugs, respectively. Overall, local injection treatment was successful in 44 patients. The 5 patients with failed treatment underwent laparotomy about 1 week after single-drug injection. Serum β-human chorionic gonadotropin (β-hCG ) levels, ectopic pregnancy mass sizes, blood flow at various points after treatment, the incidence of pelvic bleeding, and the time for serum β-hCG levels to return to normal and the mass to resolve were analyzed in the remaining 44 patients. Single-drug treatment was successful in 18 patients; 10 of 23 had low to moderate pelvic bleeding after treatment, and 5 were referred for surgery. All 26 patients were successfully treated by multiple-drug injection. Only 2 patients had a small amount of pelvic bleeding. Differences between groups were statistically significant (P injection under color Doppler guidance is a new, safe, and effective method for treating unruptured ectopic pregnancies. It accelerates the serum β-hCG decline and facilitates mass resolution. This regimen is associated with a very low rate of pelvic bleeding, improves the success rate of conservative treatment, and, therefore, has value as an important clinical application.

  17. Rapid colorimetric assay for gentamicin injection.

    Science.gov (United States)

    Tarbutton, P

    1987-01-01

    A rapid colorimetric method for determining gentamicin concentration in commercial preparations of gentamicin sulfate injection was developed. Methods currently available for measuring gentamicin concentration via its colored complex with cupric ions in alkaline solution were modified to reduce the time required for a single analysis. The alkaline copper tartrate (ACT) reagent solution was prepared such that each milliliter contained 100 mumol cupric sulfate, 210 mumol potassium sodium tartrate, and 1.25 mmol sodium hydroxide. The assay involves mixing 0.3 mL gentamicin sulfate injection 40 mg/mL (of gentamicin), 1.0 mL ACT reagent, and 0.7 mL water; the absorbance of the resulting solution at 560 nm was used to calculate the gentamicin concentration in the sample. For injections containing 10 mg/mL of gentamicin, the amount of the injection was increased to 0.5 mL and water decreased to 0.5 mL. The concentration of gentamicin in samples representing 11 lots of gentamicin sulfate injection 40 mg/mL and 8 lots of gentamicin sulfate injection 10 mg/mL was determined. The specificity, reproducibility, and accuracy of the assay were assessed. The colored complex was stable for at least two hours. Gentamicin concentration ranged from 93.7 to 108% and from 95 to 109% of the stated label value of the 40 mg/mL and the 10 mg/mL injections, respectively. No components of the preservative system present in the injections interfered with the assay. Since other aminoglycosides produced a colored complex, the assay is not specific for gentamicin. The assay was accurate and reproducible over the range of 4-20 mg of gentamicin. This rapid and accurate assay can be easily applied in the hospital pharmacy setting.

  18. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Results: Safe injection procedures regarding final waste disposal were sufficiently adopted, while measures regarding disposable injection equipment, waste containers, hand hygiene, as well as injection practices were inadequately carried out. Lack of job aid posters that promote safe injection and safe disposal of ...

  19. Autologous blood versus corticosteroid local injection for treatment of Lateral Epicondylosis: A Randomized Clinical Trial

    Directory of Open Access Journals (Sweden)

    Ajit Singh,

    2013-08-01

    Full Text Available Objective: The objective of the present single blinded prospective randomized control trial was assessment of efficacy of autologous blood injection versus local steroid injection in treatment of lateral epicondylosis of elbow. Methodology: Using a pre-post experimental design, a total of sixty patients of previously untreated lateral epicondylosis were selected; Group 1 (n=30 was administered single injection of autologous blood and Group 2 (n=30 single local corticosteroid injection. Assessment was done at baseline, 2 weeks, 6 weeks and 12 weeks using PRTEE (Patient Rated Tennis Elbow Evaluation score. Results: Pre injection parameters showed no difference between groups (chi square test, p > 0.005. Analysis between groups showed significant decrease in steroid group at very short term - 2 weeks (unpaired t test, p < 0.005.There was no difference between groups at 6 weeks. There was a significant improvement in blood group at medium term -12 weeks (unpaired t test, p < 0.05. Conclusion: Both the interventions were effective in reducing pain and improving functional status of patients in short term, but autologous blood was more effective in longer run.

  20. Platelet-rich plasma for chronic lateral epicondylitis: is one injection sufficient?

    Science.gov (United States)

    Glanzmann, Michael C; Audigé, Laurent

    2015-12-01

    Chronic lateral epicondylitis is generally treated using nonsurgical methods including physiotherapy and infiltrations of cortisone or platelet-rich plasma (PRP). The latter is known for its simple application as well as associated low risk of adverse events, which lend to its widespread use in treating various musculoskeletal conditions. There is limited evidence on the effectiveness of PRP injections to optimally treat chronic lateral epicondylitis. This study explored the effectiveness of single or repeated injections for patients with symptoms that spanned 6 months or more and were unresponsive to alternate conservative measures. Patients with chronic lateral epicondylitis received PRP injections in 4-week intervals that were complemented with standardized physical therapy. Patient-reported outcomes based on the patient-rated elbow evaluation (PREE), quick disabilities of the arm, shoulder and hand (qDASH), and EuroQol (five dimensions) 3-level version (EQ5D3L) questionnaires were documented at each visit including 6 months after the first injection. These outcomes were compared between patients receiving 1 vs. 2 or 3 PRP injections. Sixty-two patients received one (n = 36) or more (n = 26) PRP injections. The mean baseline to 6-month follow-up scores of the PREE and qDASH questionnaires improved significantly from 54.0 to 23.0 and 50.3 to 20.7, respectively. The mean baseline EQ5D3L-visual analogue scale score improved from 62.5 to 82.9 by 6 months post-injection. These outcomes did not significantly differ between the patients who received varying numbers of injections. Patients with chronic lateral epicondylitis reported significant pain relief and gain in function as well as quality of life 6 months after localized PRP treatment. A single PRP injection may be sufficient.

  1. Optical trapping and binding of particles in an optofluidic stable Fabry-Pérot resonator with single-sided injection.

    Science.gov (United States)

    Gaber, Noha; Malak, Maurine; Marty, Frédéric; Angelescu, Dan E; Richalot, Elodie; Bourouina, Tarik

    2014-07-07

    In this article, microparticles are manipulated inside an optofluidic Fabry-Pérot cylindrical cavity embedding a fluidic capillary tube, taking advantage of field enhancement and multiple reflections within the optically-resonant cavity. This enables trapping of suspended particles with single-side injection of light and with low optical power. A Hermite-Gaussian standing wave is developed inside the cavity, forming trapping spots at the locations of the electromagnetic field maxima with a strong intensity gradient. The particles get arranged in a pattern related to the mechanism affecting them: either optical trapping or optical binding. This is proven to eventually translate into either an axial one dimensional (1D) particle array or a cluster of particles. Numerical simulations are performed to model the field distributions inside the cavity allowing a behavioral understanding of the phenomena involved in each case.

  2. Effects on mitochondrial metabolism in livers of guinea pigs after a single or repeated injection of As sub 2 O sub 3

    Energy Technology Data Exchange (ETDEWEB)

    Reichl, F.X.; Kreppel, H.; Forth, W. (Muenchen Univ. (Germany, F.R.). Walter-Straub-Institut fuer Pharmakologie und Toxikologie); Szinicz, L. (Akademie des Sanitaets- und Gesundheitswesens der Bundeswehr, Muenchen (Germany, F.R.). Inst. fuer Pharmakologie und Toxikologie)

    1989-09-01

    Differences in the metabolite pattern were observed in previous experiments in guinea pig livers after a single injection or prolonged (5 days) treatment with AS{sub 2}O{sub 3} (Reichl et al. 1988). To elucidate the underlying mechanism the effect of As{sub 2}O{sub 3} on liver metabolism was therefore investigated. Male guinea pigs received either a single dose (s.d.) of As{sub 2}O{sub 3} 10 mgxkg{sup -1} s.c. or repeated doses (r.d.) of 2.5 mgxkg{sup -1} b.i.d. on 5 consecutive days. One hour after the s.d. or 1 h and 16 h after the last injection in the r.d. groups the animals were sacrificed in anaesthesia. The livers were removed by freeze clamping for the determination of various metabolites. In the s.d. group a significant decrease in hydroxybutyrate, acetylCoA, adenosinemonophosphate and in the ratio of hydroxybutyrate/acetoacetate and an increase in pyruvate, citrate, malate, and adenosinetriphosphate were observed. A significant decrease in glycogen, pyruvate, {alpha}-ketoglutarate, acetylCoA, and acetoacetate and a significant increase in malate and in the ratios of lactate/pyruvate and hydroxybutyrate/acetoacetate were observed in the r.d.1-h group. In the r.d.16-h group a significant decrease in glycogen, pyruvate, lactate, and adenosinemonophosphate was found, but the values tended towards control values. The data are consistent with mechanisms of As{sub 2}O toxicity in other species as PDH inhibition with consecutive citric acid cycle and gluconeogenesis inhibition and excessive carbohydrate depletion. (orig.).

  3. Single-pass BPM system of the Photon Factory storage ring.

    Science.gov (United States)

    Honda, T; Katoh, M; Mitsuhashi, T; Ueda, A; Tadano, M; Kobayashi, Y

    1998-05-01

    At the 2.5 GeV ring of the Photon Factory, a single-pass beam-position monitor (BPM) system is being prepared for the storage ring and the beam transport line. In the storage ring, the injected beam position during the first several turns can be measured with a single injection pulse. The BPM system has an adequate performance, useful for the commissioning of the new low-emittance lattice. Several stripline BPMs are being installed in the beam transport line. The continuous monitoring of the orbit in the beam transport line will be useful for the stabilization of the injection energy as well as the injection beam orbit.

  4. Injection molded polymer chip for electrochemical and electrophysiological recordings from single cells

    DEFF Research Database (Denmark)

    Tanzi, Simone; Larsen, Simon Tylsgaard; Taboryski, Rafael J.

    We present a novel method to fabricate an all in polymer injection molded chip for electrochemical cell recordings and lateral cell trapping. The complete device is molded in thermoplastic polymer and it results from assembling two halves. We tested spin-coated conductive polymer poly(3,4-ethylen...

  5. A laser-induced-fluorescence visualization study of transverse, sonic fuel injection in a nonreacting supersonic combustor

    Science.gov (United States)

    Mcdaniel, J. C.; Graves, J., Jr.

    1986-01-01

    The present paper reports work which has been conducted in the first phase of a research program which is to provide a data base of spatially-resolved measurements in nonreacting supersonic combustors. In the measurements, a nonintrusive diagnostic technique based on the utilization of laser-induced fluorescence (LIF) is employed. The reported work had the objective to conduct LIF visualization studies of the injection of a simulated fuel into a Mach 2.07 airstream for comparison with corresponding numerical calculations. Attention is given to injection from a single orifice into a constant-area duct, injection from a single orifice behind a rearward-facing step, and injection from staged orifices behind a rearward-facing step.

  6. Effect of main injection timing for controlling the combustion phasing of a homogeneous charge compression ignition engine using a new dual injection strategy

    International Nuclear Information System (INIS)

    Das, Pranab; Subbarao, P.M.V.; Subrahmanyam, J.P.

    2015-01-01

    Highlights: • A new dual injection concept is developed by minimum geometry modification. • The occurrence of combustion parameters strongly depend on main injection timing. • At higher load, premixed equivalence ratio dominates over main injection timing. • Retarded of main injection timing tends to retard combustion phasing. • Slightly retarded main injection timing is recommended to avoid intense knocking. - Abstract: Homogeneous charge compression ignition combustion of diesel fuel is implemented using a novel dual injection strategy. A new experimental technique is developed to modify a single cylinder direct injection diesel engine to run on homogeneous combustion mode. Effect of main injection timing is investigated covering a range from 26 to 8 crank angle degrees before top dead center with an interval of 3°. Retarded main injection timing is identified as a control strategy for delaying combustion phasing and a means of controlled combustion phasing of direct injection homogeneous charge compression ignition combustion. Two load conditions were investigated and it was observed that at higher load, start of combustion depends more on fuel air equivalence ratio than main injection timing, whereas at low load, it significantly varies with varying main injection timing. Significant improvements in smoke and oxides of nitrogen emissions are observed when compared with the baseline conventional combustion. By studying different combustion parameters, it is observed that there is an improvement in performance and emissions with marginal loss in thermal efficiency when the main injection timing is 20° before top dead center. This is identified as the optimum main injection timing for such homogeneous combustion under the same operating condition

  7. Sustainment of spherical tokamak by means of repetitive injection of compact torus plasma

    International Nuclear Information System (INIS)

    Shimamura, Shin; Matsura, Ken; Takahashi, Tsutomu; Nogi, Yasuyuki

    2000-01-01

    Sustainment of spherical tokamak (S.T.) has been studied. A compact torus (C.T.) plasma was injected into confinement region by magnetized coaxial gun. For start-up and sustainment of large main spherical tokamak, single pulsed injection of small C.T. is not sufficient in many cases. C.T.plasma injection of high repetition rate is required. For this purpose magnetized coaxial gun was driven with high repetition rate current. The first injected C.T. plasma could start-up S.T. without other help. The repetitive C.T. injection grew and sustained the S.T. plasma. A CCD camera with fast gated image intensifier took a cross sectional view of S.T. during the repetitive C.T. injection. (author)

  8. Effect of fuel injection pressure and injection timing of Karanja biodiesel blends on fuel spray, engine performance, emissions and combustion characteristics

    International Nuclear Information System (INIS)

    Agarwal, Avinash Kumar; Dhar, Atul; Gupta, Jai Gopal; Kim, Woong Il; Choi, Kibong; Lee, Chang Sik; Park, Sungwook

    2015-01-01

    Highlights: • Effect of FIP on microscopic spray characteristics. • Effect of FIP and SOI timing on CRDI engine performance, emissions and combustion. • Fuel injection duration shortened, peak injection rate increased with increasing FIP. • SMD (D 32 ) and AMD (D 10 ) of fuel droplets decreased for lower biodiesel blends. • Increase in biodiesel blend ratio and FIP, fuel injection duration decreased. - Abstract: In this investigation, effect of 10%, 20% and 50% Karanja biodiesel blends on injection rate, atomization, engine performance, emissions and combustion characteristics of common rail direct injection (CRDI) type fuel injection system were evaluated in a single cylinder research engine at 300, 500, 750 and 1000 bar fuel injection pressures at different start of injection timings and constant engine speed of 1500 rpm. The duration of fuel injection slightly decreased with increasing blend ratio of biodiesel (Karanja Oil Methyl Ester: KOME) and significantly decreased with increasing fuel injection pressure. The injection rate profile and Sauter mean diameter (D 32 ) of the fuel droplets are influenced by the injection pressure. Increasing fuel injection pressure generally improves the thermal efficiency of the test fuels. Sauter mean diameter (D 32 ) and arithmetic mean diameter (D 10 ) decreased with decreasing Karanja biodiesel content in the blend and significantly increased for higher blends due to relatively higher fuel density and viscosity. Maximum thermal efficiency was observed at the same injection timing for biodiesel blends and mineral diesel. Lower Karanja biodiesel blends (up to 20%) showed lower brake specific hydrocarbon (BSHC) and carbon monoxide (BSCO) emissions in comparison to mineral diesel. For lower Karanja biodiesel blends, combustion duration was shorter than mineral diesel however at higher fuel injection pressures, combustion duration of 50% blend was longer than mineral diesel. Up to 10% Karanja biodiesel blends in a CRDI

  9. Electrostatic injection kicker for the KEK digital accelerator

    Directory of Open Access Journals (Sweden)

    Toshikazu Adachi

    2013-05-01

    Full Text Available An electrostatic injection kicker (ES-Kicker has been developed and installed in the KEK digital accelerator, which is a synchrotron aimed at accelerating all ion species. The ES-Kicker kicks an injected ion beam horizontally into the ring orbit and consists of two main electrodes for electric field generation and three intermediate electrodes to correct field homogeneity. In our single-turn injection scheme, the circulating beam and the injected beam both pass through the electrode aperture of the kicker, so the kicker field must be turned off before arrival of the first circulating beam. The ES-Kicker is therefore operated in a pulse mode. This means that the excitation circuit for the ES-Kicker must be carefully designed, since the falling edge of the electric field is strongly affected by parasitic capacitance of this circuit, and any remaining field may disturb the circulating beam. This paper describes performance of the ES-Kicker on the basis of simulations and measurement results.

  10. Low pressure powder injection moulding of stainless steel powders

    Energy Technology Data Exchange (ETDEWEB)

    Zampieron, J.V.; Soares, J.P.; Mathias, F.; Rossi, J.L. [Powder Processing Center CCP, Inst. de Pesquisas Energeticas e Nucleares, Sao Paulo, SP (Brazil); Filho, F.A. [IPEN, Inst. de Pesquisas Energeticas e Nucleares, Cidade Univ., Sao Paulo, SP (Brazil)

    2001-07-01

    Low-pressure powder injection moulding was used to obtain AISI 316L stainless steel parts. A rheological study was undertaken using gas-atomised powders and binders. The binders used were based on carnauba wax, paraffin, low density polyethylene and microcrystalline wax. The metal powders were characterised in terms of morphology, particle size distribution and specific surface area. These results were correlated to the rheological behaviour. The mixture was injected in the shape of square bar specimens to evaluate the performance of the injection process in the green state, and after sintering. The parameters such as injection pressure, viscosity and temperature were analysed for process optimisation. The binders were thermally removed in low vacuum with the assistance of alumina powders. Debinding and sintering were performed in a single step. This procedure shortened considerably the debinding and sintering time. (orig.)

  11. Relative Bioavailability of a Single 4-mg Dose of Somatropin Administered by Subcutaneous Injection or by Needle-free Device and Coadministered With the Growth Hormone Inhibitor Octreotide Acetate in Healthy Adult Subjects.

    Science.gov (United States)

    Brimhall, Darin B; Petri, Niclas; D'Angelo, Pina

    2018-05-01

    Somatropin, used to treat growth hormone deficiency, has been traditionally administered by subcutaneous (SC) injection with needle and syringe. Needle-free devices offer ease of administration and may improve adherence and outcomes. This study evaluated the relative bioavailability of somatropin delivered with a needle-free device compared with traditional SC injection. In this randomized, single-dose, crossover study, healthy adults aged 18 to 35 years received single 4-mg doses of somatropin via a needle-free device or SC injection, along with octreotide to suppress endogenous growth hormone production. Blood samples were analyzed for serum somatropin and insulin-like growth factor-1 (IGF-1) concentrations over 24 hours after somatropin dosing. Pharmacokinetic and pharmacodynamic parameters were evaluated by using noncompartmental methods, and bioequivalence was determined based on ln transformation of the AUC 0-24 , AUC 0-∞ , C max , area under the effect-time curve from time 0 to 24 hours (AUEC 0-24 ), and maximum effect concentration (E max ). Bioequivalence was concluded if the 90% CIs of the needle-free device compared with the SC injection, constructed by using the two 1-sided hypotheses at the α = 0.05 level, for these pharmacokinetic/pharmacodynamic parameters fell within the 80.00% to125.00% regulatory acceptance range. A total of 57 subjects completed both study periods and were included in the pharmacokinetic analyses. Point estimates (90% CIs) of the geometric mean ratio (needle-free device/SC injection) based on serum somatropin were 1.013 (0.987-1.040) for AUC 0-24 , 1.012 (0.986-1.038) for AUC 0-∞ , and 1.200 (1.137-1.267) for C max . For IGF-1, baseline-corrected point estimates (90% CIs) were 0.901 (0.818-0.993) for AUEC 0-24 and 0.867 (0.795-0.946) for E max . Non-baseline-corrected values were 0.978 (0.953-1.004) for AUEC 0-24 and 0.953 (0.923-0.984) for E max . Both treatments were well tolerated; blood glucose levels increased in nearly

  12. Polymeric microchip for the simultaneous determination of anions and cations by hydrodynamic injection using a dual-channel sequential injection microchip electrophoresis system.

    Science.gov (United States)

    Gaudry, Adam J; Nai, Yi Heng; Guijt, Rosanne M; Breadmore, Michael C

    2014-04-01

    A dual-channel sequential injection microchip capillary electrophoresis system with pressure-driven injection is demonstrated for simultaneous separations of anions and cations from a single sample. The poly(methyl methacrylate) (PMMA) microchips feature integral in-plane contactless conductivity detection electrodes. A novel, hydrodynamic "split-injection" method utilizes background electrolyte (BGE) sheathing to gate the sample flows, while control over the injection volume is achieved by balancing hydrodynamic resistances using external hydrodynamic resistors. Injection is realized by a unique flow-through interface, allowing for automated, continuous sampling for sequential injection analysis by microchip electrophoresis. The developed system was very robust, with individual microchips used for up to 2000 analyses with lifetimes limited by irreversible blockages of the microchannels. The unique dual-channel geometry was demonstrated by the simultaneous separation of three cations and three anions in individual microchannels in under 40 s with limits of detection (LODs) ranging from 1.5 to 24 μM. From a series of 100 sequential injections the %RSDs were determined for every fifth run, resulting in %RSDs for migration times that ranged from 0.3 to 0.7 (n = 20) and 2.3 to 4.5 for peak area (n = 20). This system offers low LODs and a high degree of reproducibility and robustness while the hydrodynamic injection eliminates electrokinetic bias during injection, making it attractive for a wide range of rapid, sensitive, and quantitative online analytical applications.

  13. Morphological and cytohistochemical evaluation of renal effects of cadmium-doped silica nanoparticles given intratracheally to rat

    International Nuclear Information System (INIS)

    Coccini, T; Roda, E; Manzo, L; Barni, S

    2013-01-01

    Renal morphological parameters were determined in rats intratracheally instilled with model cadmium-containing silica nanoparticles (Cd-SiNPs, 1mg/rat), also exploring whether their potential modifications would be associated with toxicogenomic changes. Cd-SiNP effects, evaluated 7 and 30 days post-exposure, were assessed by (i) histopathology (Haematoxylin/Eosin Staining), (ii) characterization of apoptotic features by TUNEL staining. Data were compared with those obtained by CdCl 2 (400μg/rat), SiNPs (600μg/rat), 0.1 ml saline. Area-specific cell apoptosis was observed in all treatment groups: cortex and inner medulla were the most affected regions. Apoptotic changes were apparent at 7 days post-exposure in both areas, and were still observable in inner medulla 30 days after treatment. Increase in apoptotic frequency was more pronounced in Cd-SiNP-treated animals compared to either CdCl 2 or SiNPs. Histological findings showed comparable alterations in the renal glomerular (cortex) architecture occurring in all treatment groups at both time-points considered. The glomeruli appeared often collapsed, showing condensed, packed mesangial and endothelial cells. Oedematous haemorrhagic glomeruli were also observed in Cd-SiNPs-treated animals. Bare SiNPs caused morphological and apoptotic changes without modifying the renal gene expression profile. These findings support the concept that multiple assays and an integrated testing strategy should be recommended to characterize toxicological responses to nanoparticles in mammalian systems.

  14. Morphological and cytohistochemical evaluation of renal effects of cadmium-doped silica nanoparticles given intratracheally to rat

    Science.gov (United States)

    Coccini, T.; Roda, E.; Barni, S.; Manzo, L.

    2013-04-01

    Renal morphological parameters were determined in rats intratracheally instilled with model cadmium-containing silica nanoparticles (Cd-SiNPs, 1mg/rat), also exploring whether their potential modifications would be associated with toxicogenomic changes. Cd-SiNP effects, evaluated 7 and 30 days post-exposure, were assessed by (i) histopathology (Haematoxylin/Eosin Staining), (ii) characterization of apoptotic features by TUNEL staining. Data were compared with those obtained by CdCl2 (400μg/rat), SiNPs (600μg/rat), 0.1 ml saline. Area-specific cell apoptosis was observed in all treatment groups: cortex and inner medulla were the most affected regions. Apoptotic changes were apparent at 7 days post-exposure in both areas, and were still observable in inner medulla 30 days after treatment. Increase in apoptotic frequency was more pronounced in Cd-SiNP-treated animals compared to either CdCl2 or SiNPs. Histological findings showed comparable alterations in the renal glomerular (cortex) architecture occurring in all treatment groups at both time-points considered. The glomeruli appeared often collapsed, showing condensed, packed mesangial and endothelial cells. Oedematous haemorrhagic glomeruli were also observed in Cd-SiNPs-treated animals. Bare SiNPs caused morphological and apoptotic changes without modifying the renal gene expression profile. These findings support the concept that multiple assays and an integrated testing strategy should be recommended to characterize toxicological responses to nanoparticles in mammalian systems.

  15. Co-Injection Resin Transfer Molding for Optimization of Integral Armor

    National Research Council Canada - National Science Library

    Fink, B

    1998-01-01

    ... enhancement over existing defense industry practices. CIRTM was invented and developed for single-step manufacturing of integral armor by enabling simultaneous injection of multiple resins into multi-layer preform...

  16. An experimental study on the effects of high-pressure and multiple injection strategies on DI diesel engine emissions

    KAUST Repository

    Yang, Seung Yeon; Chung, Suk-Ho

    2013-01-01

    An experimental study on effects of high-pressure injections in conjunction with split fuel injections were conducted on an AVL single cylinder DI diesel engine. Various injection schemes were studied through the use of an electronically controlled

  17. Failure of botulinum toxin injection for neurogenic detrusor overactivity: Switch of toxin versus second injection of the same toxin.

    Science.gov (United States)

    Peyronnet, Benoit; Castel-Lacanal, Evelyne; Manunta, Andréa; Roumiguié, Mathieu; Marque, Philippe; Rischmann, Pascal; Gamé, Xavier

    2015-12-01

    To evaluate the efficacy of a second injection of the same toxin versus switching to a different botulinum toxin A after failure of a first detrusor injection in patients with neurogenic detrusor overactivity. The charts of all patients who underwent detrusor injections of botulinum toxin A (either abobotulinumtoxinA or onabotulinumtoxinA) for the management of neurogenic detrusor overactivity at a single institution were retrospectively reviewed. Patients in whom a first detrusor injection had failed were included in the present study. They were managed by a second injection of the same toxin at the same dosage or by a new detrusor injection using a different botulinum toxin A. Success was defined as a resolution of urgency, urinary incontinence and detrusor overactivity in a patient self-catheterizing seven times or less per 24 h. A total of 58 patients were included for analysis. A toxin switch was carried out in 29 patients, whereas the other 29 patients received a reinjection of the same toxin at the same dose. The success rate was higher in patients who received a toxin switch (51.7% vs. 24.1%, P = 0.03). Patients treated with a switch from abobotulinumtoxinA to onabotulinumtoxinA and those treated with a switch from onabotulinumtoxinA to abobotulinumtoxinA had similar success rates (52.9% vs. 50%, P = 0.88). After failure of a first detrusor injection of botulinum toxin for neurogenic detrusor overactivity, a switch to a different toxin seems to be more effective than a second injection of the same toxin. The replacement of onabotulinumtoxin by abobotulinumtoxin or the reverse provides similar results. © 2015 The Japanese Urological Association.

  18. Compact toroid injection fueling in a large field-reversed configuration

    Science.gov (United States)

    Asai, T.; Matsumoto, T.; Roche, T.; Allfrey, I.; Gota, H.; Sekiguchi, J.; Edo, T.; Garate, E.; Takahashi, Ts.; Binderbauer, M.; Tajima, T.

    2017-07-01

    A repetitively driven compact toroid (CT) injector has been developed for the large field-reversed configuration (FRC) facility of the C-2/C-2U, primarily for particle refueling. A CT is formed and injected by a magnetized coaxial plasma gun (MCPG) exclusively developed for the C-2/C-2U FRC. To refuel the particles of long-lived FRCs, multiple CT injections are required. Thus, a multi-stage discharge circuit was developed for a multi-pulsed CT injection. The drive frequency of this system can be adjusted up to 1 kHz and the number of CT shots per injector is two; the system can be further upgraded for a larger number of injection pulses. The developed MCPG can achieve a supersonic ejection velocity in the range of ~100 km s-1. The key plasma parameters of electron density, electron temperature and the number of particles are ~5  ×  1021 m-3, ~30 eV and 0.5-1.0  ×  1019, respectively. In this project, single- and double-pulsed counter CT injection fueling were conducted on the C-2/C-2U facility by two CT injectors. The CT injectors were mounted 1 m apart in the vicinity of the mid-plane. To avoid disruptive perturbation on the FRC, the CT injectors were operated at the lower limit of the particle inventory. The experiments demonstrated successful refueling with a significant density build-up of 20-30% of the FRC particle inventory per single CT injection without any deleterious effects on the C-2/C-2U FRC.

  19. Effects of a single glucocorticoid injection on propylene glycol-treated cows with clinical ketosis.

    Science.gov (United States)

    van der Drift, Saskia G A; Houweling, Martin; Bouman, Marina; Koets, Ad P; Tielens, Aloysius G M; Nielen, Mirjam; Jorritsma, Ruurd

    2015-05-01

    This study investigated the metabolic effects of glucocorticoids when administered to propylene glycol-treated cows with clinical ketosis. Clinical ketosis was defined by depressed feed intake and milk production, and a maximal score for acetoacetate in urine. All cows received 250 mL oral propylene glycol twice daily for 3 days and were randomly assigned to a single intramuscular injection with sterile isotonic saline solution (n = 14) or dexamethasone-21-isonicotinate (n = 17). Metabolic blood variables were monitored for 6 days and adipose tissue variables for 3 days. β-Hydroxybutyrate (BHBA) concentrations in blood decreased in all cows during treatment, but were lower in glucocorticoid-treated cows. Cows treated with glucocorticoids had higher plasma glucose and insulin concentrations, whereas concentrations of non-esterified fatty acids, 3-methylhistidine and growth hormone were unaffected. mRNA expression of hormone-sensitive lipase, BHBA receptor and peroxisome proliferator-activated receptor type γ in adipose tissue was not affected. This shows that lipolytic effects do not appear to be important in ketotic cows when glucocorticoids are combined with PG. Plasma 3-methyl histidine concentrations were similar in both groups, suggesting that glucocorticoids did not increase muscle breakdown and that the greater rise in plasma glucose in glucocorticoid-treated cows may not be due to increased supply of glucogenic amino acids from muscle. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Investigations of needle-free jet injections.

    Science.gov (United States)

    Schramm-Baxter, J R; Mitragotri, S

    2004-01-01

    Jet injection is a needle-free drug delivery method in which a high-speed stream of fluid impacts the skin and delivers drugs. Although a number of jet injectors are commercially available, especially for insulin delivery, they have a low market share compared to needles possibly due to occasional pain associated with jet injection. Jets employed by the traditional jet injectors penetrate deep into the dermal and sub-dermal regions where the nerve endings are abundantly located. To eliminate the pain associated with jet injections, we propose to utilize microjets that penetrate only into the superficial region of the skin. However, the choice of appropriate jet parameters for this purpose is challenging owing to the multiplicity of factors that determine the penetration depth. Here, we describe the dependence of jet injections into human skin on the power of the jet. Dermal delivery of liquid jets was quantified using two measurements, penetration of a radiolabeled solute, mannitol, into skin and the shape of jet dispersion in the skin which was visualized using sulforhodamine B. The dependence of the amount of liquid delivered in the skin and the geometric measurements of jet dispersion on nozzle diameter and jet velocity was captured by a single parameter, jet power.

  1. MgO by injection CVD

    International Nuclear Information System (INIS)

    Abrutis, A.; Kubilius, V.; Teiserkis, A.; Bigelyte, V.; Vengalis, B.; Jukna, A.; Butkute, R.

    1997-01-01

    Epitaxial YBa 2 Cu 3 O 7 layers with 45 in-plane orientation have been grown by injection CVD on MgO substrates polished off-axis to within 1.4-1.9 of the [100] direction. This new single-source CVD process is based on computer-controlled injection of precise microdoses of a metal-organic precursor solution into a CVD reactor. A wide range of solution compositions was tested to investigate compositional effects on phase purity, surface morphology, texturing and superconducting properties of the prepared films. The highest quality films with pure 45 texture had a smooth surface, zero resistance T c (R=0) of 88-89 K, and critical current density J c (77 K) above 10 6 A/cm 2 . (orig.) and critical current density J c (77 K) above 10 6 A/cm 2 . (orig.)

  2. Elimination of radioactivity after intratracheal instillation of tritiated 3, 4-benzopyrene in hamsters

    Energy Technology Data Exchange (ETDEWEB)

    Pylev, L N; Roe, F J.C.; Warwick, G P

    1969-01-01

    Injection and recovery experiments of tritiated 3,4-benzopyrene (BaP) injected alone or with particulate carriers into hamsters were performed. After 21 days, asbestos or carbon black carriers had significantly increased the retention of BaP in the lung. Elimination was rapid at first (2 weeks: and little influenced by carrier; slower rate of elimination was noted after that. Carriers increased recoverable macrophages but decreased the amount of radioactivity per macrophage. Radioactivity was similar in all groups for kidney, liver, blood, feces, and urine.

  3. A new rat model of portal hypertension induced by intraportal injection of microspheres

    Science.gov (United States)

    Li, Xiang-Nong; Benjamin, IS; Alexander, B

    1998-01-01

    AIM: To produce a new rat model of portal hypertension by intraportal injection of microspheres. METHODS: Measured aliquots of single or different-sized microspheres (15, 40, 80μm) were injected into the portal vein to block intrahepatic portal radicals. The resultant changes in arterial,portal,hepatic venous and splenic pulp pressures were monitored. The liver and lungs were excised for histological examination. RESULTS: Portal venous pressure was elevated from basal value of 0.89-1.02 kPa to a steady-state of 1.98-3.19 kPa following the sequential injections of single- or different-sized microspheres, with a markedly lowered mean arterial pressure. However, a small-dose injection of 80 μm microspheres (1.8 × 105) produced a steady-state portal venous pressure of 2.53 × 0.17 kPa, and all rats showed normal arterial pressures. In addition, numerous microspheres were found in the lungs in all experimental groups. CONCLUSION: Portal hypertension can be reproduced in rats by intraportal injection of microspheres at a small dose of 80 μm (1.8 × 105). Intrahepatic portal-systemic shunts probably exist in the normal rat liver. PMID:11819236

  4. Subchronic immunotoxicity and screening of reproductive toxicity and developmental immunotoxicity following single instillation of HIPCO-single-walled carbon nanotubes: purity-based comparison.

    Science.gov (United States)

    Park, Eun-Jung; Choi, Je; Kim, Jae-Ho; Lee, Byoung-Seok; Yoon, Cheolho; Jeong, Uiseok; Kim, Younghun

    2016-10-01

    Impurity has been suggested as an important factor determining toxicity following exposure to single-walled carbon nanotubes (SWCNTs). In this study, we first compared immunotoxicity based on iron content on day 90 after a single intratracheal instillation of SWCNTs in male and female mice. The inflammatory responses were generally stronger in mice exposed to acid-purified (P)-SWCNTs compared to raw (R)-SWCNTs. In addition, both R- and P-SWCNTs induced Th1-polarized immune responses with apoptotic death of BAL cells and systemically impaired the function of antigen-presenting cells (APC). We also screened reproductive and developmental toxicity by cohabitating male and female mice on day 14 after instillation. Interestingly, the pregnancy rate rapidly decreased following exposure to both types of SWCNTs, especially R-SWCNTs. In addition, we investigated developmental immunotoxicity of the offspring on day 28 after exposure to both types of SWCNTs. Their hematological changes were clearer relative to those of the parents and a significant decrease in the alkaline phosphatase and potassium levels was observed in mice of both sexes exposed to the higher dose of R- and P-SWCNTs. In conclusion, we suggest that SWCNTs may induce Th1-polarized immune responses accompanied by suppression of APC function on day 90 after a single instillation without significant iron content dependance. In addition, the consecutive exposure of SWCNTs to the subsequent generation may exacerbate metabolic and hematological disturbance. Furthermore, our results underscore the need to clarify the reproductive and developmental health effects of SWCNTs.

  5. Histopathological Alterations after Single Epidural Injection of Ropivacaine, Methylprednizolone Acetate, or Contrast Material in Swine

    International Nuclear Information System (INIS)

    Kitsou, Maria-Chrysanthi; Kostopanagiotou, Georgia; Kalimeris, Konstantinos; Vlachodimitropoulos, Demetrios; Soultanis, Konstantinos; Batistaki, Chrysanthi; Kelekis, Alexis

    2011-01-01

    Purpose: The consequences from the injection of different types of drugs in the epidural space remains unknown. Increasing evidence suggests that localized inflammation, fibrosis, and arachnoiditis can complicate sequential epidural blockades, or even epidural contrast injection. We investigate the in vivo effect of epidural injections in the epidural space in an animal model. Materials and Methods: A group of ten male adult pigs, five punctures to each at distinct vertebral interspaces under general anesthesia, were examined, testing different drugs, used regularly in the epidural space (iopamidol, methylprednisolone acetate, ropivacaine). Each site was marked with a percutaneous hook wire marker. Histological analysis of the epidural space, the meninges, and the underlying spinal cord of the punctured sites along with staining for caspase-3 followed 20 days later. Results: The epidural space did not manifest adhesions or any other pathology, and the outer surface of the dura was not impaired in any specimen. The group that had the contrast media injection showed a higher inflammation response compared to the other groups (P = 0.001). Positive staining for caspase-3 was limited to <5% of neurons with all substances used. Conclusion: No proof of arachnoiditis and/or fibrosis was noted in the epidural space with the use of the above-described drugs. A higher inflammation rate was noted with the use of contrast media.

  6. On-line grid impedance estimation based on harmonic injection for grid-connected PV inverter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Teodorescu, Remus; Blaabjerg, Frede

    2007-01-01

    two different signal processing algorithms. The DFT technique is used for the single harmonic injection and the statistic technique is used for the double harmonic injection. The grid impedance estimation is used for compliance with the anti-islanding requirements of the German standard (VDE0126...

  7. Determination of the optional time for taking blood samples by single intravenous injection of 3H-leucine

    International Nuclear Information System (INIS)

    Meng Delian; Yao Junhu; Lu Jinyin; Wu Xiaobin; Liu Jun

    2003-01-01

    Twenty four young hens (1.5 kg of body weight, BW) were randomly divided into 4 groups. Every group was diet free (FAS) or force-fed a nitrogen-free diet (NFD) or the diet with 20% crude protein in which soybean meal or cotton seed meal was the sole nitrogen source (30 g DM/kg BW). 30 μCi 3 H-Leu/kg BW was intravenously injected into all birds just after force-fed or on fasting. Venous blood samples were taken at 5, 30 min, 4,24,36 and 48h after injection. The excreta during the whole period of 48h after injection was collected. Special radioactivities of nonprotein plasma at every time point and excreta were measured. The optional time of taking blood samples was 20-24 hours after injected 3 H-Leu

  8. Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal-atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Pena, Francisco; Lavilla, Isela; Bendicho, Carlos

    2008-01-01

    Single-drop microextraction (SDME) and sequential injection analysis have been hyphenated for ultratrace metal determination by Electrothermal-Atomic Absorption Spectrometry (ETAAS). The novel method was targeted on extraction of the Cr(VI)-APDC chelate and encompasses the potential of SDME as a miniaturized and virtually solvent-free preconcentration technique, the ability of sequential injection analysis to handle samples and the versatility of furnace autosamplers for introducing microliter samples in ETAAS. The variables influencing the microextraction of Cr(VI) onto an organic solvent drop, i.e., type of organic solvent, microextraction time, stirring rate of the sample solution, drop volume, immersion depth of the drop, salting-out effect, temperature of the sample, concentration of the complexing agent and pH of the sample solution were fully investigated. For a 5 and 20 min microextraction time, the preconcentration factors were 20 and 70, respectively. The detection limit was 0.02 μg/L of Cr(VI) and the repeatability expressed as relative standard deviation was 7%. The SDME-SIA-ETAAS technique was validated against BCR CRM 544 (lyophilized solution) and applied to ultrasensitive determination of Cr(VI) in natural waters

  9. Immersed single-drop microextraction interfaced with sequential injection analysis for determination of Cr(VI) in natural waters by electrothermal-atomic absorption spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Pena, Francisco; Lavilla, Isela [Departamento de Quimica Analitica y Alimentaria, Area de Quimica Analitica, Facultad de Quimica, Universidad de Vigo, Campus As Lagoas-Marcosende, s/n, 36310 Vigo (Spain); Bendicho, Carlos [Departamento de Quimica Analitica y Alimentaria, Area de Quimica Analitica, Facultad de Quimica, Universidad de Vigo, Campus As Lagoas-Marcosende, s/n, 36310 Vigo (Spain)], E-mail: bendicho@uvigo.es

    2008-04-15

    Single-drop microextraction (SDME) and sequential injection analysis have been hyphenated for ultratrace metal determination by Electrothermal-Atomic Absorption Spectrometry (ETAAS). The novel method was targeted on extraction of the Cr(VI)-APDC chelate and encompasses the potential of SDME as a miniaturized and virtually solvent-free preconcentration technique, the ability of sequential injection analysis to handle samples and the versatility of furnace autosamplers for introducing microliter samples in ETAAS. The variables influencing the microextraction of Cr(VI) onto an organic solvent drop, i.e., type of organic solvent, microextraction time, stirring rate of the sample solution, drop volume, immersion depth of the drop, salting-out effect, temperature of the sample, concentration of the complexing agent and pH of the sample solution were fully investigated. For a 5 and 20 min microextraction time, the preconcentration factors were 20 and 70, respectively. The detection limit was 0.02 {mu}g/L of Cr(VI) and the repeatability expressed as relative standard deviation was 7%. The SDME-SIA-ETAAS technique was validated against BCR CRM 544 (lyophilized solution) and applied to ultrasensitive determination of Cr(VI) in natural waters.

  10. Performance Analysis of Multi Stage Safety Injection Tank

    International Nuclear Information System (INIS)

    Shin, Soo Jai; Kim, Young In; Bae, Youngmin; Kang, Han-Ok; Kim, Keung Koo

    2015-01-01

    In general the integral reactor has such characteristics, the integral reactor requires a high flow rate of coolant safety injection at the initial stage of the accident in which the core level is relatively fast decreased, A medium flow rate of coolant safety injection at the early and middle stages of the accident in which the coolant discharge flow rate is relatively large due to a high internal pressure of the reactor vessel, and a low flow rate of coolant safety injection is required at the middle and late stages of the accident in which the coolant discharge flow rate is greatly reduced due to a decreased pressure of the reactor vessel. It is noted that a high flow rate of the integral reactor is quite smaller compared to a flow rate required in the commercial loop type reactor. However, a nitrogen pressurized safety injection tank has been typically designed to quickly inject a high flow rate of coolant when the internal pressure of the reactor vessel is rapidly decreased, and a core makeup tank has been designed to safely inject at a single mode flow rate due to a gravitational head of water subsequent to making a pressure balance between the reactor vessel and core makeup tank. As a result, in order to compensate such a disadvantage, various type systems are used in a complicated manner in a reactor according to the required characteristic of safety injection during an accident. In the present study, we have investigated numerically the performance of the multi stage safety injection tank. A parameter study has performed to understand the characteristics of the multi stage safety injection tank. The performance of the multi stage safety injection tank has been investigated numerically. When an accident occurs, the coolant in the multi stage safety injection tank is injected into a reactor vessel by a gravitational head of water subsequent to making a pressure balance between the reactor and tank. At the early stages of the accident, the high flow rate of

  11. Performance Analysis of Multi Stage Safety Injection Tank

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Soo Jai; Kim, Young In; Bae, Youngmin; Kang, Han-Ok; Kim, Keung Koo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    In general the integral reactor has such characteristics, the integral reactor requires a high flow rate of coolant safety injection at the initial stage of the accident in which the core level is relatively fast decreased, A medium flow rate of coolant safety injection at the early and middle stages of the accident in which the coolant discharge flow rate is relatively large due to a high internal pressure of the reactor vessel, and a low flow rate of coolant safety injection is required at the middle and late stages of the accident in which the coolant discharge flow rate is greatly reduced due to a decreased pressure of the reactor vessel. It is noted that a high flow rate of the integral reactor is quite smaller compared to a flow rate required in the commercial loop type reactor. However, a nitrogen pressurized safety injection tank has been typically designed to quickly inject a high flow rate of coolant when the internal pressure of the reactor vessel is rapidly decreased, and a core makeup tank has been designed to safely inject at a single mode flow rate due to a gravitational head of water subsequent to making a pressure balance between the reactor vessel and core makeup tank. As a result, in order to compensate such a disadvantage, various type systems are used in a complicated manner in a reactor according to the required characteristic of safety injection during an accident. In the present study, we have investigated numerically the performance of the multi stage safety injection tank. A parameter study has performed to understand the characteristics of the multi stage safety injection tank. The performance of the multi stage safety injection tank has been investigated numerically. When an accident occurs, the coolant in the multi stage safety injection tank is injected into a reactor vessel by a gravitational head of water subsequent to making a pressure balance between the reactor and tank. At the early stages of the accident, the high flow rate of

  12. Are needle-free injections a useful alternative for growth hormone therapy in children? Safety and pharmacokinetics of growth hormone delivered by a new needle-free injection device compared to a fine gauge needle.

    NARCIS (Netherlands)

    Dorr, H.G.; Zabransky, S.; Keller, E.; Otten, B.J.; Partsch, C.J.; Nyman, L.; Gillespie, B.K.; Lester, N.R.; Wilson, A.M.; Hyren, C.; Kuijck, M.A. van; Schuld, P.; Schoenfeld, S.L.

    2003-01-01

    The clinical safety, use and pharmacokinetics of a new needle-free device for delivery of growth hormone (GH) were compared with those of conventional needle injection devices. In an open-label, randomized, 4-period crossover study, 18 healthy adults received single subcutaneous injections of

  13. Hydrogen pellet injection into Alcator C

    International Nuclear Information System (INIS)

    Greenwald, M.

    1983-09-01

    A four-shot pneumatic pellet injector, based on an ORNL design, has been built and operated on the Alcator C tokamak at MIT. The injector fires four independently-timed frozen hydrogen pellets with velocities in the range 8 x 10 4 - 1 x 10 5 cm/sec. Each contains 6 x 10 19 particles which corresponds to = 2 x 10 14 /cm 3 . The objectives of this experiment are to study pellet fueling and penetration, particle confinement, dependence of energy confinement on density profile and fueling mode, and edge physics and recycling as a function of fueling mode. Typical pre-injection plasmas have had anti n/sub e/ = 2 - 3 x 10 14 , Bt = 80 - 100 kG, Ip = 400 - 500 kA, T/sub e/(0) = 1200 - 1500 ev. A single pellet injected into this plasma will roughly double the electron density. Record plasma densities have been obtained by multiple injections. Line average densities in excess of 8 x 10 14 have been achieved, with highly peaked profiles. Central densities of 1.5 - 2 x 10 15 have been measured

  14. Liposomal bupivacaine as a single-injection peripheral nerve block: a dose-response study.

    Science.gov (United States)

    Ilfeld, Brian M; Malhotra, Nisha; Furnish, Timothy J; Donohue, Michael C; Madison, Sarah J

    2013-11-01

    Currently available local anesthetics approved for single-injection peripheral nerve blocks have a maximum duration of fashion. The end points included the maximum voluntary isometric contraction (MVIC) of the quadriceps femoris muscle and tolerance to cutaneous electrical current in the femoral nerve distribution. Measurements were performed from baseline until quadriceps MVIC returned to 80% of baseline bilaterally. There were statistically significant dose responses in MVIC (0.09%/mg, SE = 0.03, 95% confidence interval [CI], 0.04-0.14, P = 0.002) and tolerance to cutaneous current (-0.03 mA/mg, SE = 0.01, 95% CI, -0.04 to -0.02, P 40 mg, tolerance to cutaneous current did not return to within 20% above baseline until after 24 hours in 100% of subjects (95% CI, 56%-100%). MVIC did not consistently return to within 20% of baseline until after 24 hours in 90% of subjects (95% CI, 54%-100%). Motor block duration was not correlated with bupivacaine dose (0.06 hour/mg, SE = 0.14, 95% CI, -0.27 to 0.39, P = 0.707). The results of this investigation suggest that deposition of a liposomal bupivacaine formulation adjacent to the femoral nerve results in a partial sensory and motor block of >24 hours for the highest doses examined. However, the high variability of block magnitude among subjects and inverse relationship of dose and response magnitude attests to the need for a phase 3 study with a far larger sample size, and that these results should be viewed as suggestive, requiring confirmation in a future trial.

  15. CFD analysis of poison injection in AHWR calandria

    International Nuclear Information System (INIS)

    Kansal, A.K.; Kamble, M.T.; Maheshwari, N.K.; Vijayan, P.K.

    2014-01-01

    The present work intends to give details of design and performance validation of SDS-2. The performance is evaluated on the basis of dispersion of poison in calandria in a given period of time. Location of injection tube and injection holes, size of jet hole and number of holes are some of the design parameters which greatly affect dispersion of poison in calandria. A Computational Fluid Dynamic (CFD) study for axial and radial injection of poison was carried out using open source CFD code OpenFOAM. CFD benchmarking was done using experiments performed by Johari (Johari et al. 1997) to identify suitable turbulence model for this problem. An experimental facility simulating poison injection in moderator in presence of calandria tubes was used to further validate the CFD model is shown in the paper. CFD analysis was carried out for axial as well as radial injection for AHWR geometry. CFD analysis using OpenFOAM has been carried out to study high pressure poison injection for single jet of Shut Down System - 2 (SDS- 2) of Advanced Heavy Water Reactor (AHWR) for various design options. CFD model used in analysis have been validated with experimental data available in literature as well as experiments performed for AHWR specific geometry. Various turbulence models are tested and their adequacy for such flow problems has been established. The CFD model is then used to simulate poison injection for two design options for AHWR and their performance is compared. (author)

  16. Tanreqing Injection Attenuates Lipopolysaccharide-Induced Airway Inflammation through MAPK/NF-κB Signaling Pathways in Rats Model

    Science.gov (United States)

    Liu, Wei; Jiang, Hong-li; Cai, Lin-li; Yan, Min; Dong, Shou-jin; Mao, Bing

    2016-01-01

    Background. Tanreqing injection (TRQ) is a commonly used herbal patent medicine for treating inflammatory airway diseases in view of its outstanding anti-inflammatory properties. In this study, we explored the signaling pathways involved in contributions of TRQ to LPS-induced airway inflammation in rats. Methods/Design. Adult male Sprague Dawley (SD) rats randomly divided into different groups received intratracheal instillation of LPS and/or intraperitoneal injection of TRQ. Bronchoalveolar Lavage Fluid (BALF) and lung samples were collected at 24 h, 48 h, and 96 h after TRQ administration. Protein and mRNA levels of tumor necrosis factor- (TNF-) α, Interleukin- (IL-) 1β, IL-6, and IL-8 in BALF and lung homogenate were observed by ELISA and real-time PCR, respectively. Lung sections were stained for p38 MAPK and NF-κB detection by immunohistochemistry. Phospho-p38 MAPK, phosphor-extracellular signal-regulated kinases ERK1/2, phospho-SAPK/JNK, phospho-NF-κB p65, phospho-IKKα/β, and phospho-IκB-α were measured by western blot analysis. Results. The results showed that TRQ significantly counteracted LPS-stimulated release of TNF-α, IL-1β, IL-6, and IL-8, attenuated cells influx in BALF, mitigated mucus hypersecretion, suppressed phosphorylation of NF-κB p65, IκB-α, ΙKKα/β, ERK1/2, JNK, and p38 MAPK, and inhibited p38 MAPK and NF-κB p65 expression in rat lungs. Conclusions. Results of the current research indicate that TRQ possesses potent exhibitory effects in LPS-induced airway inflammation by, at least partially, suppressing the MAPKs and NF-κB signaling pathways, in a general dose-dependent manner. PMID:27366191

  17. Safe injection practices for administration of propofol.

    Science.gov (United States)

    King, Cecil A; Ogg, Mary

    2012-03-01

    Sepsis and postoperative infection can occur as a result of unsafe practices in the administration of propofol and other injectable medications. Investigations of infection outbreaks have revealed the causes to be related to bacterial growth in or contamination of propofol and unsafe medication practices, including reuse of syringes on multiple patients, use of single-use medication vials for multiple patients, and failure to practice aseptic technique and adhere to infection control practices. Surveys conducted by AORN and other researchers have provided additional information on perioperative practices related to injectable medications. In 2009, the US Food and Drug Administration and the Centers for Disease Control and Prevention convened a group of clinicians to gain a better understanding of the issues related to infection outbreaks and injectable medications. The meeting participants proposed collecting data to persuade clinicians to adopt new practices, developing guiding principles for propofol use, and describing propofol-specific, site-specific, and practitioner-specific injection techniques. AORN provides resources to help perioperative nurses reduce the incidence of postoperative infection related to medication administration. Copyright © 2012 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  18. SIMULATIONS OF BOOSTER INJECTION EFFICIENCY FOR THE APS-UPGRADE

    Energy Technology Data Exchange (ETDEWEB)

    Calvey, J.; Borland, M.; Harkay, K.; Lindberg, R.; Yao, C.-Y.

    2017-06-25

    The APS-Upgrade will require the injector chain to provide high single bunch charge for swap-out injection. One possible limiting factor to achieving this is an observed reduction of injection efficiency into the booster synchrotron at high charge. We have simulated booster injection using the particle tracking code elegant, including a model for the booster impedance and beam loading in the RF cavities. The simulations point to two possible causes for reduced efficiency: energy oscillations leading to losses at high dispersion locations, and a vertical beam size blowup caused by ions in the Particle Accumulator Ring. We also show that the efficiency is much higher in an alternate booster lattice with smaller vertical beta function and zero dispersion in the straight sections.

  19. Multiturn Injection into Accumulators for Heavy Ion Inertial Fusion

    CERN Document Server

    Prior, C R

    1996-01-01

    The injection of heavy ions into high current rings is complicated because it is impossible to use charge exchange in material foils to produce the singly charged heavy ions needed to keep space charge manageable on the one hand, and because losses need to be rigorously restricted to < 1 % on the other. With these constraints, the number of turns that may be injected by conventional multiturn injection is limited. This paper describes how the number may be increased by a two-dimensional technique of painting Lissajous-like patterns in x-y space, using an inclined or a corner septum. Simulation examples are presented showing the nature of the beam created in the accumulator and the likely effects of space charge forces.

  20. A new electrode design for ambipolar injection in organic semiconductors.

    Science.gov (United States)

    Kanagasekaran, Thangavel; Shimotani, Hidekazu; Shimizu, Ryota; Hitosugi, Taro; Tanigaki, Katsumi

    2017-10-17

    Organic semiconductors have attracted much attention for low-cost, flexible and human-friendly optoelectronics. However, achieving high electron-injection efficiency is difficult from air-stable electrodes and cannot be equivalent to that of holes. Here, we present a novel concept of electrode composed of a bilayer of tetratetracontane (TTC) and polycrystalline organic semiconductors (pc-OSC) covered by a metal layer. Field-effect transistors of single-crystal organic semiconductors with the new electrodes of M/pc-OSC/TTC (M: Ca or Au) show both highly efficient electron and hole injection. Contact resistance for electron injection from Au/pc-OSC/TTC and hole injection from Ca/pc-OSC/TTC are comparable to those for electron injection from Ca and hole injection from Au, respectively. Furthermore, the highest field-effect mobilities of holes (22 cm 2  V -1  s -1 ) and electrons (5.0 cm 2  V -1  s -1 ) are observed in rubrene among field-effect transistors with electrodes so far proposed by employing Ca/pc-OSC/TTC and Au/pc-OSC/TTC electrodes for electron and hole injection, respectively.One of technological challenges building organic electronics is efficient injection of electrons at metal-semiconductor interfaces compared to that of holes. The authors show an air-stable electrode design with induced gap states, which support Fermi level pinning and thus ambipolar carrier injection.

  1. Multiple collagenase injections are safe for treatment of Dupuytren's contractures.

    Science.gov (United States)

    Gajendran, Varun K; Hentz, Vincent; Kenney, Deborah; Curtin, Catherine M

    2014-07-01

    The authors report the case of a 65-year-old, right-hand-dominant man who had severe Dupuytren's disease with multiple cords and flexion contractures of the metacarpophalangeal and proximal interphalangeal joints of both hands and underwent repeated collagenase injections for treatment. Collagenase has been shown to be safe and effective in the treatment of Dupuytren's contractures when administered as a single dose, but the results of multiple injections over a prolonged period are unknown. Antibodies to collagenase develop in all patients after several treatments, raising concerns about safety and efficacy as a result of sensitization from repeated exposures. The antibodies generated as a result of repeated exposure to collagenase could theoretically render it less effective with time and could also lead to immune reactions as severe as anaphylaxis. The authors present the case of a single patient who experienced continued correction of his contractures with only minor and self-limited adverse reactions after administration of 12 collagenase doses through 15 injections during a 4-year period. Over time, the injections continued to be effective at correcting metacarpophalangeal joint contractures, but less effective at correcting proximal interphalangeal joint contractures. The patient did eventually require a fasciectomy, but the safety and modest success of the repeated collagenase injections shows promise for a less invasive treatment with a better risk profile than open fasciectomy. Although further studies are needed, repeated administration of collagenase appears to be safe and modestly effective for severe Dupuytren's contractures, although a fasciectomy may ultimately be required in the most severe cases. Copyright 2014, SLACK Incorporated.

  2. Single well surfactant test to evaluate surfactant floods using multi tracer method

    Science.gov (United States)

    Sheely, Clyde Q.

    1979-01-01

    Data useful for evaluating the effectiveness of or designing an enhanced recovery process said process involving mobilizing and moving hydrocarbons through a hydrocarbon bearing subterranean formation from an injection well to a production well by injecting a mobilizing fluid into the injection well, comprising (a) determining hydrocarbon saturation in a volume in the formation near a well bore penetrating formation, (b) injecting sufficient mobilizing fluid to mobilize and move hydrocarbons from a volume in the formation near the well bore, and (c) determining the hydrocarbon saturation in a volume including at least a part of the volume of (b) by an improved single well surfactant method comprising injecting 2 or more slugs of water containing the primary tracer separated by water slugs containing no primary tracer. Alternatively, the plurality of ester tracers can be injected in a single slug said tracers penetrating varying distances into the formation wherein the esters have different partition coefficients and essentially equal reaction times. The single well tracer method employed is disclosed in U.S. Pat. No. 3,623,842. This method designated the single well surfactant test (SWST) is useful for evaluating the effect of surfactant floods, polymer floods, carbon dioxide floods, micellar floods, caustic floods and the like in subterranean formations in much less time and at much reduced cost compared to conventional multiwell pilot tests.

  3. Distribution and excretion of mercury compounds in rats over a long period after a single injection

    Energy Technology Data Exchange (ETDEWEB)

    Swensson, A; Ulfvarson, U

    1968-01-01

    Rats were given single subcutaneous injections of methyl mercuric hydroxide, mercury (II) nitrate and phenyl mercuric hydroxide. The elimination of the compounds and the concentration in the organs at different times were followed by means of isotope techniques, for almost 6 months. The rate of excretion changes during the observation period. A calculated biological half-life therefore will be different from time to time. If the elimination during the first 9 days is considered the half-life is 5 days for mercury (II) nitrate and phenyl mercuric hydroxide and 16 days for methyl mercuric hydroxide. After this the excretion rate becomes slower and slower. The distribution in the organs varies during the first part of the period. The blood concentration decreases rapidly for all compounds, while the concentrations in the kidneys increases and reaches a maximum after some days. The same holds true for the brain and testis when mercury (II) nitrate and methyl mercuric hydroxide are considered. The elimination from the kidneys, the brain and the testes is slower than from other organs for all compounds. The concentrations in different parts of the brain are rather similar, though somewhat higher concentration in lobus olfactorius is indicated.

  4. Spray combustion of biomass-based renewable diesel fuel using multiple injection strategy in a constant volume combustion chamber

    KAUST Repository

    Jing, Wei

    2016-05-26

    Effect of a two-injection strategy associated with a pilot injection on the spray combustion process was investigated under conventional diesel combustion conditions (1000 K and 21% O2 concentration) for a biomass-based renewable diesel fuel, i.e., biomass to liquid (BTL), and a regular No. 2 diesel in a constant volume combustion chamber using multiband flame measurement and two-color pyrometry. The spray combustion flame structure was visualized by using multiband flame measurement to show features of soot formation, high temperature and low temperature reactions, which can be characterized by the narrow-band emissions of radicals or intermediate species such as OH, HCHO, and CH. The objective of this study was to identify the details of multiple injection combustion, including a pilot and a main injection, and to provide further insights on how the two injections interact. For comparison, three injection strategies were considered for both fuels including a two-injection strategy (Case TI), single injection strategy A (Case SA), and single injection strategy B (Case SB). Multiband flame results show a strong interaction, indicated by OH emissions between the pilot injection and the main injection for Case TI while very weak connection is found for the narrow-band emissions acquired through filters with centerlines of 430 nm and 470 nm. A faster flame development is found for the main injection of Case TI compared to Cases SA and SB, which could be due to the high temperature environment and large air entrainment from the pilot injection. A lower soot level is observed for the BTL flame compared to the diesel flame for all three injection types. Case TI has a lower soot level compared to Cases SA and SB for the BTL fuel, while the diesel fuel maintains a similar soot level among all three injection strategies. Soot temperature of Case TI is lower for both fuels, especially for diesel. Based on these results, it is expected that the two-injection strategy could be

  5. New injection scheme using a pulsed quadrupole magnet in electron storage rings

    Directory of Open Access Journals (Sweden)

    Kentaro Harada

    2007-12-01

    Full Text Available We demonstrated a new injection scheme using a single pulsed quadrupole magnet (PQM with no pulsed local bump at the Photon Factory Advanced Ring (PF-AR in High Energy Accelerator Research Organization (KEK. The scheme employs the basic property of a quadrupole magnet, that the field at the center is zero, and nonzero elsewhere. The amplitude of coherent betatron oscillation of the injected beam is effectively reduced by the PQM; then, the injected beam is captured into the ring without largely affecting the already stored beam. In order to investigate the performance of the scheme with a real beam, we built the PQM providing a higher field gradient over 3  T/m and a shorter pulse width of 2.4  μs, which is twice the revolution period of the PF-AR. After the field measurements confirmed the PQM specifications, we installed it into the ring. Then, we conducted the experiment using a real beam and consequently succeeded in storing the beam current of more than 60 mA at the PF-AR. This is the first successful beam injection using a single PQM in electron storage rings.

  6. A Pressure Injection System for Investigating the Neuropharmacology of Information Processing in Awake Behaving Macaque Monkey Cortex.

    Science.gov (United States)

    Veith, Vera K; Quigley, Cliodhna; Treue, Stefan

    2016-03-14

    The top-down modulation of feed-forward cortical information processing is functionally important for many cognitive processes, including the modulation of sensory information processing by attention. However, little is known about which neurotransmitter systems are involved in such modulations. A practical way to address this question is to combine single-cell recording with local and temporary neuropharmacological manipulation in a suitable animal model. Here we demonstrate a technique combining acute single-cell recordings with the injection of neuropharmacological agents in the direct vicinity of the recording electrode. The video shows the preparation of the pressure injection/recording system, including preparation of the substance to be injected. We show a rhesus monkey performing a visual attention task and the procedure of single-unit recording with block-wise pharmacological manipulations.

  7. Development of a 100 W, single frequency, CW Nd:YAG Laser

    International Nuclear Information System (INIS)

    Veitch, P.J.; Mudge, D.; Munch, J.; Hamilton, M.W.; Ostermeyer, M.; Hosken, D.; Brooks, A.

    2002-01-01

    Full text: High power, diode-laser-pumped, continuous wave (cw) solid-state lasers with excellent beam quality, efficiency and reliability are required for demanding applications, including gravitational wave interferometry, where current additional requirements include single frequency, low noise and Nd:YAG. Our approach is a chain of injection locked laser oscillators, theoretically capable of achieving the lowest noise possible. We use a single-frequency (100 mW) master laser to injection lock a medium-power (10 W) laser that in turn injection locks a 100 W laser. Injection locking requires an optimized, single mode, power slave laser at each stage. We shall describe the nearly completed 10 W brass-board laser, which will also be deployed at the ACIGA Test Facility at Gingin. We shall also describe our 100 W laser using a scalable diode pumping scheme, an active control of thermal lensing and a stable-unstable resonator. Initial tests showed mode control to be limited by thermal focusing and thermally induced birefringence in the Nd:YAG medium at 70 W output. Recent efforts have identified the source of the thermal lens and significantly reduced its magnitude, leading to a modified design. We shall present our latest results from the experiments to demonstrate single mode, single frequency laser at 100 W

  8. A Single-blind, Split-face, Randomized, Pilot Study Comparing the Effects of Intradermal and Intramuscular Injection of Two Commercially Available Botulinum Toxin A Formulas to Reduce Signs of Facial Aging

    Science.gov (United States)

    Sapra, Priya; Sapra, Sheetal; Khanna, Julie; Mraud, Kelli; Bonadonna, Jennifer

    2017-01-01

    Objective: To examine the effectiveness of intradermal botulinum toxin type A injection in improving skin texture and midface lift while reducing pore size and sebum production, as well as investigate the differences in effectiveness between onabotulinumtoxinA and abobotulinumtoxinA using intradermal and intramuscular injection methods. Design: A 16-week, single-blind, split-face, randomized study. Each patient served as their own control, receiving onabotulinumtoxinA and abobotulinumtoxinA randomized to either the left or right side of the face. Patients received intradermal botulinum toxin type A injections at Week 0 and intramuscular botulinum toxin type A injections at Week 2. Participants: Ten women aged 35 to 65 years who exhibited static rhytids in the glabellar and periorbital area. Measurements: The primary endpoint was efficacy of split-face treatment of intradermal and intramuscular onabotulinumtoxinA and abobotulinumtoxinA as assessed by a blinded evaluator using baseline and post-treatment photographs. The secondary endpoints included safety as assessed by adverse events and patient satisfaction measured by questionnaires completed at baseline and post-treatment. Results: Intradermal injection of botulinum toxin type A led to a statistically significant improvement in skin texture (p=0.004) while also resulting in mild midface lift (p=0.024), but did not provide a significant reduction of pore size and sebum production. There was no statistically significant difference between onabotulinumtoxinA and abobotulinumtoxinA when injected intradermally or intramuscularly. Conclusion: Intradermal injection of botulinum toxin type A appears to be a safe and effective therapy that provides an improvement in facial skin texture and midface lift. Registry: clinicaltrials.gov (ID#: NCT02907268). PMID:28367260

  9. Anti-anaphylactic action of nordihydroguaiaretic acid in antigen sensitized guinea pigs.

    Science.gov (United States)

    Bergren, Dale R; Valentine, Jimmie L

    2016-12-01

    Therapeutic natural products and medicinal herbs has gained popularity. The anti-antigenic action of the plant alkaloid nordihydroguaiaretic acid (NDGA) was studied in ovalbumin (OA)-sensitized guinea pigs. In one series of experiments conscious, non-sedated guinea pigs were challenged with OA aerosol. Specific airway resistance (SR AW ) was monitored using a two-chambered whole-body plethysmograph. OA aerosol increased SR AW above that produced by vehicle administration. Prior NDGA administration by a 1min 0.9% aerosol (w/vol) attenuated the increase in SR AW resulting from OA challenge. In the anesthetized guinea pig pretreated with indomethacin, pyrilamine and propranolol, intravenous OA injection increased intra-tracheal pressure above vehicle injection. Intravenous NDGA administration (5mg/kg) reduced the intra-tracheal pressure increases. In a third series of experiments plasma leukotriene C 4 was measured by radio-immunoassay in 3 groups challenged with OA aerosol: vehicle-treated OA-sensitized, OA-sensitized receiving NDGA and vehicle treated guinea pigs. NDGA pretreatment reduced plasma LTC 4 in response to OA challenge in OA sensitized guinea pigs. This study demonstrates that NDGA is an effective antigenic agent when given by aerosol or intravenous injection in either conscious or anesthetized guinea pigs, respectively. The mechanism of action of NDGA is presumed primarily be due to the blockage of 5-lipoxygenase and therefore the synthesis of leukotrienes. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Injectable loop recorder implantation in an ambulatory setting by advanced practice providers: Analysis of outcomes.

    Science.gov (United States)

    Kipp, Ryan; Young, Natasha; Barnett, Anne; Kopp, Douglas; Leal, Miguel A; Eckhardt, Lee L; Teelin, Thomas; Hoffmayer, Kurt S; Wright, Jennifer; Field, Michael

    2017-09-01

    Implantable loop recorder (ILR) insertion has historically been performed in a surgical environment such as the electrophysiology (EP) lab. The newest generation loop recorder (Medtronic Reveal LINQ™, Minneapolis, MN, USA) is injectable with potential for implantation in a non-EP lab setting by advanced practice providers (APPs) facilitating improved workflow and resource utilization. We report the safety and efficacy of injectable ILR placement in the ambulatory care setting by APPs. A retrospective review was performed including all patients referred for injectable ILR placement from March 2014 to November 2015. All device placement procedures were performed in an ambulatory care setting using the standard manufacturer deployment kit with sterile technique and local anesthetic following a single dose of intravenous antibiotics. Acute procedural success and complication rates following injectable ILR placement in the ambulatory setting were reviewed. During the study period, 125 injectable ILRs were implanted. Acute procedural success with adequate sensing (R-waves ≥ 0.2 mV) occurred in 100% of patients. There were no acute procedural complications. Subacute complications occurred in two patients (1.6% of implantations), including one possible infection treated with oral antibiotics and one device removal due to pain at the implant site. In this retrospective single-center study, implantation of injectable ILR in an ambulatory care setting by APPs following a single dose of intravenous antibiotics and standard manufacturer technique yielded a low complication rate with high acute procedural success. Use of this implantation strategy may improve EP lab workflow while providing a safe and effective technique for device placement. © 2017 Wiley Periodicals, Inc.

  11. Bladder base/trigone injection is safe and as effective as bladder body injection of onabotulinumtoxinA for idiopathic detrusor overactivity refractory to antimuscarinics.

    Science.gov (United States)

    Kuo, Hann-Chorng

    2011-09-01

    The purpose of this study was to evaluate the efficacy and safety of onabotulinumtoxinA injections at bladder base/trigone and compare with injections at bladder body or bladder body/trigone for the treatment of idiopathic detrusor overactivity (IDO) refractory to antimuscarinics. A single blind, randomized, paralleled, actively controlled trial was performed in patients with urodynamically proven IDO who failed antimuscarinic therapy. Patients were randomly assigned to receive intravesical injections of 100 U of onabotulinumtoxinA into three different bladder sites. All treatments were evaluated by voiding diary variables, urgency severity score, urodynamic studies, and patient perception of bladder condition. Long-term success rates over 12 months were also determined. Among the patients, 37 were randomized to injections in the bladder body, 35 into the bladder body/trigone, and 33 into the bladder base/trigone. Successful results were reported in 76 (72%) patients at 3 months: 26 (70%) in the bladder body group, 26 (74%) in the bladder body/trigone group, and 24 (73%) in the bladder base/trigone group. There were no significant differences in success rates, changes in urgency and urgency incontinence episodes, urodynamic variables, or long-term success rates among the three subgroups. The incidence of adverse events was similar among three groups. No vesicoureteral reflux was noted in all patients with or without involving trigone injection. Intravesical onabotulinumtoxinA injection is an effective treatment for IDO regardless of the bladder injection site. Bladder base/trigone injection is as safe and effective as bladder body injections with or without trigone involvement. Copyright © 2011 Wiley-Liss, Inc.

  12. Pellet injection experiments on tokamaks in ASIPP, China

    International Nuclear Information System (INIS)

    Yang, Y.; Bao, Y.; Li, J.; Gu, X.; He, Y.

    1999-01-01

    Pellet Injection has been proven to be an effective method for deep fuelling of fusion devices. Improvements of both the particle confinement and the energy confinement were observed in many experiments. In HT-6M and HT-7 tokamaks, single and multi-pellet experiments are tried, and attractive results are obtained

  13. Computational simulation of multi-strut central lobed injection of hydrogen in a scramjet combustor

    Directory of Open Access Journals (Sweden)

    Gautam Choubey

    2016-09-01

    Full Text Available Multi-strut injection is an approach to increase the overall performance of Scramjet while reducing the risk of thermal choking in a supersonic combustor. Hence computational simulation of Scramjet combustor at Mach 2.5 through multiple central lobed struts (three struts have been presented and discussed in the present research article. The geometry and model used here is slight modification of the DLR (German Aerospace Center scramjet model. Present results show that the presence of three struts injector improves the performance of scramjet combustor as compared to single strut injector. The combustion efficiency is also found to be highest in case of three strut fuel injection system. In order to validate the results, the numerical data for single strut injection is compared with experimental result which is taken from the literature.

  14. Pharmacokinetics and tissue distribution of enrofloxacin after single intramuscular injection in Pacific white shrimp.

    Science.gov (United States)

    Fang, X; Zhou, J; Liu, X

    2018-02-01

    The pharmacokinetic properties and tissue distribution of enrofloxacin (EF) were investigated after single intramuscular (i.m.) dose of 10 mg/kg body weight (b.w.) in Pacific white shrimp at 22 to 25°C. EF and its metabolite ciprofloxacin (CF) were determined by high-performance liquid chromatography. After i.m. administration, EF was absorbed quickly, and the peak of EF concentration (C max ) reached at first time point in hemolymph. The volume of distribution V d(area) of EF was 3.84 L/kg, indicating that the distribution of EF was good. The area under the concentration-time curve (AUC) of EF was 90.1 and 274.2 μg hr/ml in muscle and hepatopancreas, respectively, which was higher than 75.8 μg hr/ml in hemolymph. The EF elimination was slow in muscle and hepatopancreas with the half-life (T 1/2β ) of 52.3 and 75.8 hr, respectively. CF, the mainly metabolite of EF, was detected in hemolymph, muscle and hepatopancreas. The C max was 0.030, 0.013 and 0.218 μg/ml, respectively. Based on a minimum inhibitory concentration (MIC) of 0.006-0.032 μg/ml for susceptible strains, EF i.m. injected at a dose 10 mg/kg could be efficacious against common pathogenic bacteria of Pacific white shrimp. © 2017 John Wiley & Sons Ltd.

  15. Long acting injectable hormonal contraceptives.

    Science.gov (United States)

    Fraser, I S

    1982-03-01

    Injectable hormonal preparations can be highly effective and satisfactory contraceptives. The two main preparations available today are depot medroxy progesterone acetate (DMPA) and norethisterone oenanthate (NET-OEN), but several other approaches are currently under clinical trial. Injectable contraceptives have some unique advantages which give them justifiably wide appeal amongst many groups of women. However, they do have a number of disadvantages including invariable menstrual disturbance and a delay in the return of fertility. One formulation of DMPA, Depo-Provera, is probably the most extensively investigated single hormonal contraceptive ever made. These studies indicate that it is remarkably safe and does not face any more unresolved issues than the combined pill, intrauterine device or tubal sterilization. However, for a number of disparate emotional and political reasons it has attracted the attention of several consumer and feminist groups, who have waged a prolonged and quite unjustified campaign against it. It is to be hoped that future debate will be conducted on a more informed, rational and less emotional basis. Injectable contraceptives should have an important place in the family planning armamentarium of all countries, and current developments should lead to a decrease in concerns about presently available agents. This should further increase the widespread acceptability of this approach to contraception.

  16. Non-Liouvillean ion injection via resonantly enhanced two-photon ionization

    Directory of Open Access Journals (Sweden)

    B. A. Knyazev

    2004-03-01

    Full Text Available The charge-exchange method is now one of the main techniques for ion injection into accelerators and storage rings. The disadvantages of conventional methods, based on the atom or ion stripping in a material target, are emittance growth, energy straggling, and production of ions in many charge states. Recently suggested stripping methods based on direct photoionization require employment of hard-UV lasers, which still do not exist and must obviously be very bulky and expensive. An alternative method, suggested for injection of proton beams, employs excitation of the atom to 3p intermediate state with subsequent Lorentz ionization in a magnetic field gradient. This technique applies rigid requirements to laser characteristic and is not free of growing of the beam divergence. In this paper a variant of the stripping technique based on the resonantly enhanced two-photon ionization (RETPI is considered. The technique allows ionization of singly charged ions of the elements from helium to bismuth. A variant of the technique can be used for proton injection. RETPI can be applied for both ion injection and stacking, as well as for diagnostics of ion beam characteristics on the orbit. Stripping efficiency can be about 100% for the singly charged ions having the singlet ground state and decreases for the other ions. Special methods for “cleaning” unwanted atomic states in such ions, that can provide high stripping efficiency, are discussed. Excimer lasers with very moderate parameters can be employed for implementation of this technique for almost all elements. Numerical examples show that for most of the singly charged ions and for hydrogen atom necessary laser-beam energy density is merely 0.5–8  J/cm^{2} for a 1 m interaction region, and is 10 times higher for several light ions.

  17. Three-Dimensional Changes in the Midface Following Malar Calcium Hydroxyapatite Injection in a Cadaver Model.

    Science.gov (United States)

    Gatherwright, James R; Brown, Matthew S; Katira, Kristopher M; Rowe, David J

    2015-08-01

    Three-dimensional (3D) changes in the midface following malar calcium hydroxyapatite (CaHa) injection have not been systematically analyzed. The authors analyzed 3D volume changes in midface and naso-labial fold (NLF) volume, as well as lateral movement in the NLF/naso-labial crease (NLC) junction following malar injection of CaHa in a cadaver model. A single surgeon injected CaHa in the supraperiosteal plane. Sequential images were obtained with the VECTRA 3D system pre- and post-1.5- and 3-cc CaHa injections. All measurements were performed by a single examiner. Injection location was verified anatomically. Injections were performed in 16 fresh cadaver hemi-faces. Maximal increases in projection were centered on the malar injection site, with associated decreases in projection and volume in the infero-medial locations. Relative mean increases in volume of 3.16 cc and 4.94 cc were observed following the 1.5-cc and 3-cc injections, respectively. There was a relative decrease in the volume of the NLF of -0.3 cc and -0.4 cc following the 1.5- and 3-cc injections, respectively. Injection of CaHa was associated with lateral movements of the NLF-NLC junction at the level of the nasal sill, philtral columns, and oral commissure, measuring 2.7, 2.5, and 1.9 mm and 2.8, 2.9, and 2.4 mm following the 1.5- and 3-cc injections, respectively. Anatomical dissection verified the location in the supraperiosteal space and within the middle malar fat pad. Following malar CaHa injection, 3D photographic analysis showed a measureable lifting effect with recruitment of ptotic tissue and lateral movement of the NLF-NLC junction in a cadaver model. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  18. The efficacy of preventive parasternal single injection of bupivacaine on intubation time, blood gas parameters, narcotic requirement, and pain relief after open heart surgery: A randomized clinical trial study

    Directory of Open Access Journals (Sweden)

    Mahmoud Saeidi

    2011-01-01

    Full Text Available Background: Postsurgical pain usually results in some complications in the patients. This study has tried to investigate the effects of parasternal single injection of bupivacaine on postoperative pulmonary and pain consequences in patients after open heart surgery. Methods: : In a prospective double blind clinical study, 100 consenting patients undergoing elective open heart surgery were randomized into two groups. In case group, bupivacaine was injected at both sides of sternum, immediately before sternal closure. In the control group, no intervention was performed. Then, the patients were investigated regarding intubation period, length of ICU stay, arterial blood gas (ABG parameters, morphine requirement, and their severity of postoperative pain using a visual analogue scale (VAS device. Results: No differences were found between the two groups regarding to age, sex, pump time, operation time, and body mass index and preoperative cardiac ejection fraction. Mean intubation length in case group was much shorter than that in control group. Mean PaO 2 in case group was lower in different checking times in postoperative period. The patients in the case group needed less morphine compared to those in the control group during the 24-hour observation period in the ICU. Finally, mean VAS scores of pain in case group were significantly lower than those in control group at 6, 12, and 24 hours postoperatively. Conclusions: Patients′ pain relief by parasternal single injection of bupivacaine in early postoperative period can facilitate earlier ventilator weaning and tracheal extubation after open heart surgery as well as achieving lower pain scores and narcotic requirements.

  19. Improved estimation of receptor density and binding rate constants using a single tracer injection and displacement

    International Nuclear Information System (INIS)

    Syrota, A.; Delforge, J.; Mazoyer, B.M.

    1988-01-01

    The possibility of improving receptor model parameter estimation using a displacement experiment in which an excess of an unlabeled ligand (J) is injected after a delay (t D ) following injection of trace amounts of the β + - labeled ligand (J*) is investigated. The effects of varying t D and J/J* on parameter uncertainties are studied in the case of 11 C-MQNB binding to myocardial acetycholine receptor using parameters identified in a dog experiment

  20. Non-injection Drug Use and Injection Initiation Assistance among People Who Inject Drugs in Tijuana, Mexico.

    Science.gov (United States)

    Ben Hamida, Amen; Rafful, Claudia; Jain, Sonia; Sun, Shelly; Gonzalez-Zuniga, Patricia; Rangel, Gudelia; Strathdee, Steffanie A; Werb, Dan

    2018-02-01

    Although most people who inject drugs (PWID) report receiving assistance during injection initiation events, little research has focused on risk factors among PWID for providing injection initiation assistance. We therefore sought to determine the influence of non-injection drug use among PWID on their risk to initiate others. We used generalized estimating equation (GEE) models on longitudinal data among a prospective cohort of PWID in Tijuana, Mexico (Proyecto El Cuete IV), while controlling for potential confounders. At baseline, 534 participants provided data on injection initiation assistance. Overall, 14% reported ever initiating others, with 4% reporting this behavior recently (i.e., in the past 6 months). In a multivariable GEE model, recent non-injection drug use was independently associated with providing injection initiation assistance (adjusted odds ratio [AOR] = 2.42, 95% confidence interval [CI] = 1.39-4.20). Further, in subanalyses examining specific drug types, recent non-injection use of cocaine (AOR = 9.31, 95% CI = 3.98-21.78), heroin (AOR = 4.00, 95% CI = 1.88-8.54), and methamphetamine (AOR = 2.03, 95% CI = 1.16-3.55) were all significantly associated with reporting providing injection initiation assistance. Our findings may have important implications for the development of interventional approaches to reduce injection initiation and related harms. Further research is needed to validate findings and inform future approaches to preventing entry into drug injecting.

  1. Injecting Artificial Memory Errors Into a Running Computer Program

    Science.gov (United States)

    Bornstein, Benjamin J.; Granat, Robert A.; Wagstaff, Kiri L.

    2008-01-01

    Single-event upsets (SEUs) or bitflips are computer memory errors caused by radiation. BITFLIPS (Basic Instrumentation Tool for Fault Localized Injection of Probabilistic SEUs) is a computer program that deliberately injects SEUs into another computer program, while the latter is running, for the purpose of evaluating the fault tolerance of that program. BITFLIPS was written as a plug-in extension of the open-source Valgrind debugging and profiling software. BITFLIPS can inject SEUs into any program that can be run on the Linux operating system, without needing to modify the program s source code. Further, if access to the original program source code is available, BITFLIPS offers fine-grained control over exactly when and which areas of memory (as specified via program variables) will be subjected to SEUs. The rate of injection of SEUs is controlled by specifying either a fault probability or a fault rate based on memory size and radiation exposure time, in units of SEUs per byte per second. BITFLIPS can also log each SEU that it injects and, if program source code is available, report the magnitude of effect of the SEU on a floating-point value or other program variable.

  2. Pellet injection experiments on tokamaks in ASIPP, China

    International Nuclear Information System (INIS)

    Yang, Y.; Bao, Y.; Li, J.; Gu, X.; He, Y.

    2001-01-01

    Pellet injection has been proved to be an effective method for deep fueling of fusion devices. Improvements of both the particle confinement and the energy confinement were observed in many experiments. In HT-6M and HT-7 tokamaks, single and multi-pellet experiments are tried, and attractive results are obtained. (author)

  3. Injection, injectivity and injectability in geothermal operations: problems and possible solutions. Phase I. Definition of the problems

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, O.J.; Crichlow, H.B.

    1979-02-14

    The following topics are covered: thermodynamic instability of brine, injectivity loss during regular production and injection operations, injectivity loss caused by measures other than regular operations, heat mining and associated reservoir problems in reinjection, pressure maintenance through imported make-up water, suggested solutions to injection problems, and suggested solutions to injection problems: remedial and stimulation measures. (MHR)

  4. Hydrogen Gas as a Fuel in Direct Injection Diesel Engine

    Science.gov (United States)

    Dhanasekaran, Chinnathambi; Mohankumar, Gabriael

    2016-04-01

    Hydrogen is expected to be one of the most important fuels in the near future for solving the problem caused by the greenhouse gases, for protecting environment and saving conventional fuels. In this study, a dual fuel engine of hydrogen and diesel was investigated. Hydrogen was conceded through the intake port, and simultaneously air and diesel was pervaded into the cylinder. Using electronic gas injector and electronic control unit, the injection timing and duration varied. In this investigation, a single cylinder, KIRLOSKAR AV1, DI Diesel engine was used. Hydrogen injection timing was fixed at TDC and injection duration was timed for 30°, 60°, and 90° crank angles. The injection timing of diesel was fixed at 23° BTDC. When hydrogen is mixed with inlet air, emanation of HC, CO and CO2 decreased without any emission (exhaustion) of smoke while increasing the brake thermal efficiency.

  5. Bioengineering of injectable encapsulated aggregates of pluripotent stem cells for therapy of myocardial infarction

    Science.gov (United States)

    Zhao, Shuting; Xu, Zhaobin; Wang, Hai; Reese, Benjamin E.; Gushchina, Liubov V.; Jiang, Meng; Agarwal, Pranay; Xu, Jiangsheng; Zhang, Mingjun; Shen, Rulong; Liu, Zhenguo; Weisleder, Noah; He, Xiaoming

    2016-10-01

    It is difficult to achieve minimally invasive injectable cell delivery while maintaining high cell retention and animal survival for in vivo stem cell therapy of myocardial infarction. Here we show that pluripotent stem cell aggregates pre-differentiated into the early cardiac lineage and encapsulated in a biocompatible and biodegradable micromatrix, are suitable for injectable delivery. This method significantly improves the survival of the injected cells by more than six-fold compared with the conventional practice of injecting single cells, and effectively prevents teratoma formation. Moreover, this method significantly enhances cardiac function and survival of animals after myocardial infarction, as a result of a localized immunosuppression effect of the micromatrix and the in situ cardiac regeneration by the injected cells.

  6. Repeated intraperitoneal injections of interleukin 1 beta induce glucose intolerance in normal rats

    DEFF Research Database (Denmark)

    Wogensen, L; Reimers, J; Mandrup-Poulsen, T

    1991-01-01

    Previous in vitro findings suggest the involvement of interleukin 1 (IL-1) in the pathogenesis of insulin-dependent diabetes mellitus. The aims of the present study were to investigate the effects of single or repeated ip injections of recombinant IL-1 beta on blood glucose and glucose tolerance...... in vivo. Normal Wistar Kyoto rats were injected ip with a single injection of 4 micrograms/kg of the mature form of recombinant IL-1 beta (amino acids 117-269) or once daily on 5 consecutive days. Control rats were given vehicle and were fed ad libitum or pair-fed together with the rIL-1 beta treated rats...... in food intake, a lasting mild depression of blood glucose (7 days) and a transiently impaired glucose tolerance on day 5. We conclude that systemic IL-1 should be considered an important regulator of glucose homeostasis in vivo....

  7. Development of New Therapeutics Targeting Biofilm Formation by the Opportunistic Pulmonary Pathogens Pseudomonas aeruginosa and Aspergillus Fumigatus

    Science.gov (United States)

    2017-10-01

    antibiotics directed at PA or at AF. We have also demonstrated that, when injected intratracheally in mice, the hydrolases did not induce adverse immune...CONTENTS 1. Introduction..........4 2. Keywords..........4 3. Accomplishments..........4 4. Impact..........27 5. Changes/Problems..........27 6. Products ...Exopolysaccharide-deficient mutants of PA and AF are less virulent in animal models, suggesting that these glycans are promising therapeutic targets. We have

  8. Study of status of safe injection practice and knowledge regarding injection safety among primary health care workers in Baglung district, western Nepal.

    Science.gov (United States)

    Gyawali, Sudesh; Rathore, Devendra S; Kc, Bhuvan; Shankar, P Ravi

    2013-01-03

    Unsafe injection practices and injection overuse are widespread in developing countries harming the patient and inviting risks to the health care workers. In Nepal, there is a dearth of documented information about injection practices so the present study was carried out: a) to determine whether the selected government health facilities satisfy the conditions for safe injections in terms of staff training, availability of sterile injectable equipment and their proper disposal after use and b) to assess knowledge and attitudes of healthcare workers in these health care facilities with regard to injection safety. A descriptive cross-sectional mixed type (qualitative and quantitative) survey was carried out from 18th May to 16th June 2012. In-depth interviews with the in-charges were conducted using a semi-structured questionnaire. Observation of the health facilities using a structured observation tool was done. The data were analysed manually by summarizing, tabulating and presenting in various formats. The in-charges (eight males, two females) who participated in the study ranged in age from 30 to 50 years with a mean age of 37.8 years. Severe infection followed by pain was the most important cause for injection use with injection Gentamicin being most commonly prescribed. New single use (disposable) injections and auto-disable syringes were used to inject curative drugs and vaccines respectively. Sufficient safety boxes were also supplied to dispose the used syringe. All health care workers had received full course of Hepatitis B vaccine and were knowledgeable about at least one pathogen transmitted through unsafe injection practices. Injection safety management policy and waste disposal guideline was not available for viewing in any of the facilities. The office staff who disposed the bio-medical wastes did so without taking any safety measures. Moreover, none of these staff had received any formal training in waste management. Certain safe injection

  9. Study of status of safe injection practice and knowledge regarding injection safety among primary health care workers in Baglung district, western Nepal

    Directory of Open Access Journals (Sweden)

    Gyawali Sudesh

    2013-01-01

    Full Text Available Abstract Background Unsafe injection practices and injection overuse are widespread in developing countries harming the patient and inviting risks to the health care workers. In Nepal, there is a dearth of documented information about injection practices so the present study was carried out: a to determine whether the selected government health facilities satisfy the conditions for safe injections in terms of staff training, availability of sterile injectable equipment and their proper disposal after use and b to assess knowledge and attitudes of healthcare workers in these health care facilities with regard to injection safety. Methodology A descriptive cross-sectional mixed type (qualitative and quantitative survey was carried out from 18th May to 16th June 2012. In-depth interviews with the in-charges were conducted using a semi-structured questionnaire. Observation of the health facilities using a structured observation tool was done. The data were analysed manually by summarizing, tabulating and presenting in various formats. Results The in-charges (eight males, two females who participated in the study ranged in age from 30 to 50 years with a mean age of 37.8 years. Severe infection followed by pain was the most important cause for injection use with injection Gentamicin being most commonly prescribed. New single use (disposable injections and auto-disable syringes were used to inject curative drugs and vaccines respectively. Sufficient safety boxes were also supplied to dispose the used syringe. All health care workers had received full course of Hepatitis B vaccine and were knowledgeable about at least one pathogen transmitted through unsafe injection practices. Injection safety management policy and waste disposal guideline was not available for viewing in any of the facilities. The office staff who disposed the bio-medical wastes did so without taking any safety measures. Moreover, none of these staff had received any formal

  10. Testosterone Injection

    Science.gov (United States)

    ... typical male characteristics. Testosterone injection works by supplying synthetic testosterone to replace the testosterone that is normally ... as a pellet to be injected under the skin.Testosterone injection may control your symptoms but will ...

  11. The popularity of injections in the Third World: origins and consequences for poliomyelitis.

    Science.gov (United States)

    Wyatt, H V

    1984-01-01

    Paralysis from poliomyelitis may follow injections yet injections are extremely popular in the Third World. Some injections are given by hospital doctors and nurses but the majority are given by traditional healers, pharmacists and paramedical workers who have acquired syringes. Many injections may be given to a sick child. I suggest that the early use of vaccines did not persuade people of the mystic of injections and that the mystic predated the use of penicillin. The earliest mystical result would have been the injection of quinine for malaria and antrypal for sleeping sickness. The words brilliant, spectacular and dramatic were first used to describe the mass campaigns against yaws and kala-azar in the 1920s and 1930s. A single injection healed the ugly lesions in a week: cause and effect were visible. In the 1950s penicillin was used in mass eradication campaigns. The countries where injections are so popular correspond roughly with the areas of mass eradication programmes. Many or perhaps most of the injections are not sterile and present a great risk of attendant paralysis. Proof that injections are causal may be impossible. Meanwhile we need to know why injections are so popular and how they can be less so.

  12. Pulmonary instillation of low doses of titanium dioxide nanoparticles in mice leads to particle retention and gene expression changes in the absence of inflammation

    DEFF Research Database (Denmark)

    Husain, Mainul; Saber, Anne Thoustrup; Guo, Charles

    2013-01-01

    We investigated gene expression, protein synthesis, and particle retention in mouse lungs following intratracheal instillation of varying doses of nano-sized titanium dioxide (nano-TiO2). Female C57BL/6 mice were exposed to rutile nano-TiO2 via single intratracheal instillations of 18, 54, and 162......μg/mouse. Mice were sampled 1, 3, and 28days post-exposure. The deposition of nano-TiO2 in the lungs was assessed using nanoscale hyperspectral microscopy. Biological responses in the pulmonary system were analyzed using DNA microarrays, pathway-specific real-time RT-PCR (qPCR), gene-specific q...

  13. Ablation of lumbar sympathetic ganglia by absolute ethanol injection and paravertebral catheter placement under CT guidance: evaluation of the efficacy

    International Nuclear Information System (INIS)

    Xu Hua; Xiong Yuanchang; Shao Chengwei; Zuo Changjing; Sheng Jing; Tian Jianming

    2009-01-01

    Objective: To evaluate the ablation of lumbar sympathetic ganglia by using single injection of absolute ethanol and retaining a paravertebral catheter under CT guidance for the treatment of lower extremity ischemia. Methods: Single absolute ethanol injection of L2 sympathetic ganglia was done in 25 cases (group B), single absolute ethanol injection of L2 sympathetic ganglia together with placement of a paravertebral catheter at L3 was carried out in 23 cases (group BT). All the procedures were performed under CT guidance. Three days after the procedure, the pain severity of the lower limbs was evaluated based on VAS method. If the patient in group BT still had a VAS score ≥4 on the third day, 3 ml of 1% lidocaine was infected via the retained catheter in the prone position. If VAS score became ≤3 at 5 min after the injection, additional 5 ml of ethanol was given through the catheter. The pain severity was evaluated again one week later. VAS score, analgesic dose and temperature of lower limbs were recorded. Results: One week after the procedure the excellent rate and effective rate for group B were 32% and 80% respectively, while for group BT were 60.9% and 95.7% respectively, with a significant difference between two groups (P<0.01). Conclusion: For the ablation of lumbar sympathetic ganglia the combination of single absolute ethanol injection with paravertebral catheter placement under CT guidance is superior to the single absolute ethanol injection. This technique is more individual with better results and is more likely to be accepted by the patients. (authors)

  14. Mode-Locking in Broad-Area Semiconductor Lasers Enhanced by Picosecond-Pulse Injection

    OpenAIRE

    Kaiser, J; Fischer, I; Elsasser, W; Gehrig, E; Hess, O

    2004-01-01

    We present combined experimental and theoretical investigations of the picosecond emission dynamics of broad-area semiconductor lasers (BALs). We enhance the weak longitudinal self-mode-locking that is inherent to BALs by injecting a single optical 50-ps pulse, which triggers the output of a distinct regular train of 13-ps pulses. Modeling based on multimode Maxwell-Bloch equations illustrates how the dynamic interaction of the injected pulse with the internal laser field efficiently couples ...

  15. A Comparative Analysis of Saffron and Methylprednisolone on Bleomycin-Induced Pulmonary Fibrosis in Rats

    Directory of Open Access Journals (Sweden)

    Mehrzad Bahtouee

    2018-04-01

    Full Text Available Background: The purpose of this study was to compare the effects of saffron and methylprednisolone on bleomycin-induced pulmonary fibrosis in rats. Methods: This study was conducted in Bushehr, southern Iran in 2017.The animals were divided into four groups of five rats each. Three groups were injected with a single intratracheal dose of bleomycin (5 mg/kg. The fourth group was administered with normal saline at the same volume (200 µl. Saffron extract dissolved in water was given to one group (100 mg /body weight orally while intraperitoneal injection of methylprednisolone (2.5 mg/kg injected to another one for 16 days. The rats were sacrificed 28 days following surgery and their right and left lungs were removed and washed for measuring lung indices, myeloperoxidase activities and finally histopathological examination. Results: Injection of bleomycin caused decrement of body weight aggravated by intraperitoneal methylprednisolone treatment. Lung indices were increased in the bleomycin-treated group compared with the control, while methylprednisolone, unlike saffron, had no preventive effects on it. Both saffron and methylprednisolone treatment prevented the increase in lung myeloperoxidase as a destructive enzyme. In addition, excessive collagen deposition and thickening of alveolar septa were significantly prevented with saffron treatment as compared to methylprednisolone injection following hematoxylin and eosin staining. Conclusion: Saffron with established antioxidant properties could prevent some detrimental effects in bleomycin-induced pulmonary fibrosis even more than methylprednisolone injection known as a standard therapy in this murine model. More investigations must be carried out to examine the beneficial or harmful effects of this remedy.

  16. Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line

    Science.gov (United States)

    Gaul, Christopher J.

    2001-01-01

    The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.

  17. A precise pointing nanopipette for single-cell imaging via electroosmotic injection.

    Science.gov (United States)

    Lv, Jian; Qian, Ruo-Can; Hu, Yong-Xu; Liu, Shao-Chuang; Cao, Yue; Zheng, Yong-Jie; Long, Yi-Tao

    2016-11-24

    The precise transportation of fluorescent probes to the designated location in living cells is still a challenge. Here, we present a new addition to nanopipettes as a powerful tool to deliver fluorescent molecules to a given place in a single cell by electroosmotic flow, indicating favorable potential for further application in single-cell imaging.

  18. Evaluation of Water Injection Effect on NO(x) Formation for a Staged Gas Turbine Combustor

    Science.gov (United States)

    Fan, L.; Yang, S. L.; Kundu, K. P.

    1996-01-01

    NO(x) emission control by water injection on a staged turbine combustor (STC) was modeled using the KIVA-2 code with modification. Water is injected into the rich-burn combustion zone of the combustor by a single nozzle. Parametric study for different water injection patterns was performed. Results show NO(x) emission will decrease after water being injected. Water nozzle location also has significant effect for NO formation and fuel ignition. The chemical kinetic model is also sensitive to the excess water. Through this study, a better understanding of the physics and chemical kinetics is obtained, this will enhance the STC design process.

  19. Cell turnover in the odontogenic organ of the rat incisor as visualized by graphic reconstructions following a single injection of 3H-thymidine.

    Science.gov (United States)

    Smith, C E

    1980-07-01

    Turnover of cells within the odontogenic organ was studied in three dimensions by preparing serial sections of incisors from young male rats killed at various times following a single intraperitoneal injection of 1 muCi/g body weight of 3H-thymidine. Radioautographs showed that at 1 hour after injection labeled cells were present in all cell layers throughout the entire depth of the odontogenic organ. They were encountered frequently within the inner dental epithelium and stratum intermedium but appeared less abundant within the stellate reticulum and outer dental epithelium. With time, the frequency of labeled cells in each layer declined progressively, and more rapidly at the anterior and labial side of the odontogenic organ than toward its posterior and lingual side. Hence labeled cells were observed over the longest time interval in regions where cell layers were in closest proximity to the opening of the apical foramen, that is, near the apical and cervical loops. By 32 days after injection, numerous labeled cells could still be identified within the outer dental epithelium and stellate reticulum near the apical loop (bulbous part of the odontogenic organ) and the outer dental epithelium near the cervical loops ("U"-shaped part of the odontogenic organ). These findings support the hypothesis that cells originate within the bulbous part of the odontogenic organ and migrate anteriorly through the "U"-shaped and root sheath parts of the odontogenic organ during renewal of the incisor. It appears that individual stem cell compartments may be maintained for surface (outer/inner dental epithelium) and intermediate layers (stellate reticulum/stratum intermedium) in the odontogenic epithelium.

  20. Injection locking of optomechanical oscillators via acoustic waves.

    Science.gov (United States)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-02

    Injection locking is an effective technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators. As such, exploring new mechanisms for injection locking of emerging oscillators is important for their usage in various systems. Here, we present the first demonstration of injection locking of a radiation pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can be easily implemented on various platforms to lock different types of OMOs independent of their size and structure. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance, matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity, and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology, and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  1. Treatment of cervical pregnancy with ultrasound-guided local methotrexate injection.

    Science.gov (United States)

    Yamaguchi, M; Honda, R; Erdenebaatar, C; Monsur, M; Honda, T; Sakaguchi, I; Okamura, Y; Ohba, T; Katabuchi, H

    2017-12-01

    Cervical pregnancy (CP) is a rare type of ectopic pregnancy. While methotrexate (MTX) is generally the first-line method of choice for clinically stable women, there is still no consensus on the most appropriate treatment for this abnormal pregnancy. The aim of this study was to investigate the efficacy of a single local MTX injection under transvaginal ultrasound guidance for the initial treatment of CP and to assess post-treatment fertility. We reviewed retrospectively 15 patients with CP treated with local MTX injection under transvaginal ultrasound guidance. In all patients, the serum human chorionic gonadotropin (hCG) levels were monitored and the gestational sac was evaluated using ultrasonography after treatment. Magnetic resonance imaging (MRI) was performed as necessary. We evaluated the patients' clinical characteristics and clinical course after treatment, the efficacy of the treatment and the post-treatment fertility in patients desiring subsequent pregnancy. The median estimated gestational age at the time of MTX injection was 6 + 2 (range, 5 + 2 to 11 + 0) weeks. All 15 patients were treated successfully, without the need for blood transfusion or surgical procedures; however, three patients required an additional local MTX injection due to a poor decline in serum hCG level following the initial injection, while one patient required uterine artery embolization due to persistent vaginal bleeding and an enlarging gestational sac with blood vessels visible on contrast-enhanced MRI. The mean time following initial MTX injection for hCG normalization was 43.8 (95% CI, 33.3-54.3) days and for resumption of menses was 68.4 (95% CI, 51.9-84.9) days. Seven of the 10 women desiring subsequent pregnancy following treatment had uneventful pregnancy, one became pregnant but miscarried spontaneously at 8 weeks of gestation, one was treated by laparoscopic surgery after diagnosis of a tubal pregnancy and one did not conceive. A single, ultrasound

  2. Administration of follitropin alfa and lutropin alfa combined in a single injection: a feasibility assessment

    Directory of Open Access Journals (Sweden)

    Agostinetto Rita

    2009-05-01

    Full Text Available Abstract Background Gonadotrophins are routinely administered in assisted reproductive technology (ART treatment protocols. Recombinant human follicle-stimulating hormone (r-hFSH; follitropin alfa and recombinant human luteinizing hormone (r-hLH; lutropin alfa can be administered individually or in a fixed combination. The ability to vary the FSH to LH dose ratio in a single injection without compromising the bioactivity of either gonadotrophin or generating losses of active principle is important for physicians and patients alike. Methods This study investigated whether follitropin alfa (GONAL-f (R, as lyophilized powder for reconstitution or solution from the GONAL-f (R (filled-by-mass [FbM] Prefilled Pen, could be used to reconstitute Pergoveris TM (follitropin alfa/lutropin alfa 150 IU/75 IU lyophilized powder. In Ratio Groups 1 and 2, the r-hFSH:r-hLH ratio was 3:1; in Ratio Groups 3 and 4, the ratios of r-hFSH:r-hLH were 5:1 and 8:1, respectively. The protein content and bioactivity of each mixed solution were evaluated. The r-hFSH and r-hLH content was determined using reverse-phase high performance liquid chromatography. The biological activity of r-hFSH and r-hLH was assessed using the Steelman-Pohley and Van Hell in vivo bioassays in rats, respectively. Results Follitropin alfa/lutropin alfa 150 IU/75 IU lyophilized powder could be successfully mixed with follitropin alfa 75 IU FbM solution that was either reconstituted from lyophilized powder or injected directly from the prefilled pen to create solutions with ratios of r-hFSH and r-hLH from 3:1 to 8:1. The measured content of r-hFSH and r-hLH corresponded favourably with the target protein content in Ratio Groups 1–4. The in vivo target and measured bioactivity of r-hFSH and r-hLH were also closely matched in all Ratio Groups. Conclusion Follitropin alfa lyophilized powder or solution can be accurately mixed with follitropin alfa/lutropin alfa 150 IU/75 IU lyophilized powder to

  3. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... sures regarding disposable injection equipment, waste containers, hand hygiene ... injection practices lead to high prevalence of NSSIs in operating rooms. .... guidelines, the availability of training courses to HCWs, and provi-.

  4. Risk factors associated with injection initiation among drug users in Northern Thailand

    Directory of Open Access Journals (Sweden)

    Suriyanon Vinai

    2006-03-01

    Full Text Available Abstract Background Circumstances surrounding injection initiation have not been well addressed in many developing country contexts. This study aimed to identify demographic factors, sexual behaviors and drug use characteristics related to injection initiation among drug users in northern Thailand. Methods A cross-sectional survey was conducted among 2,231 drug users admitted to the Northern Drug Treatment Center in Mae Rim, Chiang Mai, Thailand, between February 1, 1999 and December 31, 2000. A multiple logistic regression was employed to identify the independent effects from potential risk factors of transition into injection. Results After controlling for other covariates, being 20 years of age or older, single, ever receiving education, urban residence, and having a history of smoking or incarceration were significantly associated with higher likelihood of injection initiation. Multiple sex partners and an experience of sex abuse were associated with an increased risk of injection initiation. Comparing to those whose first drug was opium, individuals using heroin as their initiation drug had greater risk of injection initiation; conversely, those taking amphetamine as their first drug had less risk of injection initiation. Age of drug initiation was negatively associated with the risk of injection initiation: the older the age of drug initiation, the less the risk of injection initiation. Conclusion Injection initiation was related to several demographic factors, sexual behaviors and drug use characteristics. Understanding these factors will benefit the design of approaches to successfully prevent or delay transition into injection.

  5. Terahertz light-emitting graphene-channel transistor toward single-mode lasing

    Science.gov (United States)

    Yadav, Deepika; Tamamushi, Gen; Watanabe, Takayuki; Mitsushio, Junki; Tobah, Youssef; Sugawara, Kenta; Dubinov, Alexander A.; Satou, Akira; Ryzhii, Maxim; Ryzhii, Victor; Otsuji, Taiichi

    2018-03-01

    A distributed feedback dual-gate graphene-channel field-effect transistor (DFB-DG-GFET) was fabricated as a current-injection terahertz (THz) light-emitting laser transistor. We observed a broadband emission in a 1-7.6-THz range with a maximum radiation power of 10 μW as well as a single-mode emission at 5.2 THz with a radiation power of 0.1 μW both at 100 K when the carrier injection stays between the lower cutoff and upper cutoff threshold levels. The device also exhibited peculiar nonlinear threshold-like behavior with respect to the current-injection level. The LED-like broadband emission is interpreted as an amplified spontaneous THz emission being transcended to a single-mode lasing. Design constraints on waveguide structures for better THz photon field confinement with higher gain overlapping as well as DFB cavity structures with higher Q factors are also addressed towards intense, single-mode continuous wave THz lasing at room temperature.

  6. Measured emittance dependence on injection method in laser plasma accelerators

    Science.gov (United States)

    Barber, Samuel; van Tilborg, Jeroen; Schroeder, Carl; Lehe, Remi; Tsai, Hai-En; Swanson, Kelly; Steinke, Sven; Nakamura, Kei; Geddes, Cameron; Benedetti, Carlo; Esarey, Eric; Leemans, Wim

    2017-10-01

    The success of many laser plasma accelerator (LPA) based applications relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot transverse emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock induced density down-ramp injection. Notably, the measurements reveal that ionization injection results in significantly higher emittance. With the down-ramp injection configuration, emittances less than 1 micron at spectral charge densities up to 2 pC/MeV were measured. This work was supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the NSF under Grant No. PHY-1415596, by the U.S. DOE NNSA, DNN R&D (NA22), and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  7. Pneumatic hydrogen pellet injection system for the ISX tokamak

    International Nuclear Information System (INIS)

    Milora, S.L.; Foster, C.A.

    1979-01-01

    We describe the design and operation of the solid hydrogen pellet injection system used in plasma refueling experiments on the ISX tokamak. The gun-type injector operates on the principle of gas dynamic acceleration of cold pellets confined laterally in a tube. The device is cooled by flowing liquid helium refrigerant, and pellets are formed in situ. Room temperature helium gas at moderate pressure is used as the propellant. The prototype device injected single hydrogen pellets into the tokamak discharge at a nominal 330 m/s. The tokamak plasma fuel content was observed to increase by (0.5--1.2) x 10 19 particles subsequent to pellet injection. A simple modification to the existing design has extended the performance to 1000 m/s. At higher propellant operating pressures (28 bars), the muzzle velocity is 20% less than predicted by an idealized constant area expansion process

  8. Spiral CT portography: correlation with different injection rate

    International Nuclear Information System (INIS)

    Wu Dong; Zhou Kangrong; Chen Zuwang; Chen Gang; Chen Jin; Chen Huiming

    2000-01-01

    Objective: To choose optimal injection rate in spiral CT portography(CTP) by comparing 3D CTP images using different injection rates. Methods: Thirty-seven patients were randomly divided into 2 groups (11 and 26 cases in each group). Single-level dynamic scan was completed at the first liver hilus, starting at 15s or 30s after initial contrast injection(2 ml/kg) with injection rate 1.5 ml/s (slow group) or 3.0 ml/s (rapid group). The continuous scan were repeated every 5s for 120s or 135s. ROI was used to measure the CT value of the portal vein and the liver parenchyma, respectively, and then the time-density curves were drawn. Spiral CT portography were performed at injection rate of 1.5 ml/s or 3.0 ml/s as the delay time designed described above, including 98 cases in rapid group and 12 cases in slow group. Both MPVR (multi-projection volume reconstruction) and MIP (maximum intensity projection) were employed for reconstruction. All images were ranked according to the grade of portal vein, the different CT value between the portal vein and the liver parenchyma, the edge's definition of blood vessel, the grade of hepatic vein and the display of IVC by 2 radiologists. Results: The maximum density difference in average between the portal vein and the liver parenchyma was 53.4 HU and 83.9 HU, respectively (t = 16.418, P < 0.001) in slow group and rapid one, and the mean reaching time was 80s and 60s, respectively (t = 13.394, P < 0.001). In slow injection group, the average score of MPVR image was 9.3, while it was 12.5 (t = 3.514, P < 0.01) in rapid injection group. Rapid group was better than slow one at the PV-L, the grade of the portal vein, and the edge's definition of blood vessel. Conclusion: Using rapid injection rate (3.0 ml/s), the maximum density difference between the portal vein and the liver parenchyma increases, and the mean reaching time shortens. The quality of 3D CTP image of rapid injection rate (3.0 ml/s) is superior to that of slow injection rate

  9. Spray and atomization of diesel fuel and its alternatives from a single-hole injector using a common rail fuel injection system

    KAUST Repository

    Chen, PinChia

    2013-01-01

    Fuel spray and atomization characteristics play an important role in the performance of internal combustion engines. As the reserves of petroleum fuel are expected to be depleted within a few decades, finding alternative fuels that are economically viable and sustainable to replace the petroleum fuel has attracted much research attention. In this work, the spray and atomization characteristics were investigated for commercial No. 2 diesel fuel, biodiesel (FAME) derived from waste cooking oil (B100), 20% biodiesel blended diesel fuel (B20), renewable diesel fuel produced in house, and civil aircraft jet fuel (Jet-A). Droplet diameters and particle size distributions were measured by a laser diffraction particle analyzing system and the spray tip penetrations and cone angles were acquired using a high speed imaging technique. All experiments were conducted by employing a common-rail high-pressure fuel injection system with a single-hole nozzle under room temperature and pressure. The experimental results showed that biodiesel and jet fuel had different features compared with diesel. Longer spray tip penetration and larger droplet diameters were observed for B100. The smaller droplet size of the Jet-A were believed to be caused by its relatively lower viscosity and surface tension. B20 showed similar characteristics to diesel but with slightly larger droplet sizes and shorter tip penetration. Renewable diesel fuel showed closer droplet size and spray penetration to Jet-A with both smaller than diesel. As a result, optimizing the trade-off between spray volume and droplet size for different fuels remains a great challenge. However, high-pressure injection helps to optimize the trade-off of spray volume and droplet sizes. Furthermore, it was observed that the smallest droplets were within a region near the injector nozzle tip and grew larger along the axial and radial direction. The variation of droplet diameters became smaller with increasing injection pressure.

  10. Comprehensive low-dose imaging of carotid and coronary arteries with a single-injection dual-source CT angiography protocol.

    Science.gov (United States)

    Tognolini, A; Arellano, C S; Marfori, W; Heidari, G; Sayre, J W; Krishnam, M S; Ruehm, S G

    2014-03-01

    To assess the feasibility of a fast single-bolus combined carotid and coronary computed tomography angiography (CTA) protocol in asymptomatic patients. Thirty-three consecutive patients (18 women and 15 men) with a median age of 61 ± 14 years old (range 37-87 years) with known or suspected atherosclerotic disease were enrolled in this prospective study. A single breath-hold, single biphasic injection protocol (50 ml at 3 ml/s, 50 ml at 5 ml/s, 50 ml saline flush at 5 ml/s) was used for combined CTA imaging of the supra-aortic (SAA) and coronary arteries (CA) on a 64-slice dual-source CT (DSCT) machine. Helical CTA acquisition of the SAA was followed by prospective electrocardiography (ECG)-triggered coronary CTA. Subjective (four-point scale) image quality and objective signal-to-noise (SNR) and contrast-to-noise (CNR) measurements were performed. Vascular disease was graded on a four-point scale (grade 1: absent; grade 2: mild, grade 3: moderate; grade 4: severe). The radiation dose was recorded for each patient. The average enhancement and subjective quality score of SAA and CA segments were 396 HU/358 HU and 1.2 ± 0.3/1.72 ± 0.4, respectively. The SNR was 27.1 ± 1.7 in the SAA and 21.6 ± 1.6 in the CA (p grade 2 and 1/33 (3%) had grade 3 disease. CA findings were as follows: 25/33 (76%) showed no disease and 6/33 (18%) patients had grade 2 and 2/33 (6%) had grade 3 disease. Five patients had disease in both districts. The average radiation dose for the combined CTA angiogram was 4.3 ± 0.6 mSv. A fast, low-dose combined DSCT angiography protocol appears technically feasible for imaging carotid and coronary atherosclerotic disease. Copyright © 2013 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  11. Acupuncture Injection Combined with Electrokinetic Injection for Polydimethylsiloxane Microfluidic Devices

    Directory of Open Access Journals (Sweden)

    Ji Won Ha

    2017-01-01

    Full Text Available We recently reported acupuncture sample injection that leads to reproducible injection of nL-scale sample segments into a polydimethylsiloxane (PDMS microchannel for microchip capillary electrophoresis. The advantages of the acupuncture injection in microchip capillary electrophoresis include capability of minimizing sample loss and voltage control hardware and capability of introducing sample plugs into any desired position of a microchannel. However, the challenge in the previous study was to achieve reproducible, pL-scale sample injections into PDMS microchannels. In the present study, we introduce an acupuncture injection technique combined with electrokinetic injection (AICEI technique to inject pL-scale sample segments for microchip capillary electrophoresis. We carried out the capillary zone electrophoresis (CZE separation of FITC and fluorescein, and the mixture of 10 μM FITC and 10 μM fluorescein was separated completely by using the AICEI method.

  12. An investigation of the effects of spray angle and injection strategy on dimethyl ether (DME) combustion and exhaust emission characteristics in a common-rail diesel engine

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Seung Hyun; Cha, June Pyo [Graduate School of Hanyang University, Hanyang University, 17 Haengdang-dong, Sungdong-gu, Seoul, 133-791 (Korea); Lee, Chang Sik [Department of Mechanical Engineering, Hanyang University, 17 Haengdang-dong, Sungdong-gu, Seoul 133-791 (Korea)

    2010-11-15

    An experimental investigation was performed on the effects of spray angle and injection strategies (single and multiple) on the combustion characteristics, concentrations of exhaust emissions, and the particle size distribution in a direct-injection (DI) compression ignition engine fueled with dimethyl ether (DME) fuel. In this study, two types of narrow spray angle injectors ({theta}{sub spray} = 70 and 60 ) were examined and its results were compared with the results of conventional spray angle ({theta}{sub spray} = 156 ). In addition, to investigate the optimal operating conditions, early single-injection and multiple-injection strategies were employed to reduce cylinder wall-wetting of the injected fuels and to promote the ignition of premixed charge. The engine test was performed at 1400 rpm, and the injection timings were varied from TDC to BTDC 40 of the crank angle. The experimental results showed that the combustion pressure from single combustion for narrow-angle injectors ({theta}{sub spray} = 70 and 60 ) is increased, as compared to the results of the wide-angle injector ({theta}{sub spray} = 156 ) with advanced injection timing of BTDC 35 . In addition, two peaks of the rate of heat release (ROHR) are generated by the combustion of air-fuel premixed mixtures. DME combustion for all test injectors indicated low levels of soot emissions at all injection timings. The NO{sub x} emissions for narrow-angle injectors simultaneously increased in proportion to the advance in injection timing up to BTDC 25 , whereas BTDC 20 for the wide-angle injector. For multiple injections, the combustion pressure and ROHR of the first injection with narrow-angle injectors are combusted more actively, and the ignition delay of the second injected fuel is shorter than with the wide-angle injector. However, the second combustion pressure and ROHR were lower than during the first injection, and combustion durations are prolonged, as compared to the wide-angle injector. With

  13. An investigation of the effects of spray angle and injection strategy on dimethyl ether (DME) combustion and exhaust emission characteristics in a common-rail diesel engine

    International Nuclear Information System (INIS)

    Yoon, Seung Hyun; Cha, June Pyo; Lee, Chang Sik

    2010-01-01

    An experimental investigation was performed on the effects of spray angle and injection strategies (single and multiple) on the combustion characteristics, concentrations of exhaust emissions, and the particle size distribution in a direct-injection (DI) compression ignition engine fueled with dimethyl ether (DME) fuel. In this study, two types of narrow spray angle injectors (θ spray = 70 and 60 ) were examined and its results were compared with the results of conventional spray angle (θ spray = 156 ). In addition, to investigate the optimal operating conditions, early single-injection and multiple-injection strategies were employed to reduce cylinder wall-wetting of the injected fuels and to promote the ignition of premixed charge. The engine test was performed at 1400 rpm, and the injection timings were varied from TDC to BTDC 40 of the crank angle. The experimental results showed that the combustion pressure from single combustion for narrow-angle injectors (θ spray = 70 and 60 ) is increased, as compared to the results of the wide-angle injector (θ spray = 156 ) with advanced injection timing of BTDC 35 . In addition, two peaks of the rate of heat release (ROHR) are generated by the combustion of air-fuel premixed mixtures. DME combustion for all test injectors indicated low levels of soot emissions at all injection timings. The NO x emissions for narrow-angle injectors simultaneously increased in proportion to the advance in injection timing up to BTDC 25 , whereas BTDC 20 for the wide-angle injector. For multiple injections, the combustion pressure and ROHR of the first injection with narrow-angle injectors are combusted more actively, and the ignition delay of the second injected fuel is shorter than with the wide-angle injector. However, the second combustion pressure and ROHR were lower than during the first injection, and combustion durations are prolonged, as compared to the wide-angle injector. With advanced timing of the first injection, narrow

  14. D2O laser pumped by an injection-locked CO2 laser for ion-temperature measurements

    International Nuclear Information System (INIS)

    Okada, Tatsuo; Ohga, Tetsuaki; Yokoo, Masakazu; Muraoka, Katsunori; Akazaki, Masanori.

    1986-01-01

    The cooperative Thomson scattering method is one of the various new techniques proposed for measuring the temperature of ions in nuclear fusion critical plasma, for which a high-performance FIR laser pumped by an injection-locked CO 2 laser is required. This report deals with D 2 O laser with a wavelength of 385 μm which is pumped by injection-locked single-mole TEA CO 2 laser composed of a driver laser and an output-stage laser. A small-sized automatic pre-ionization type laser is employed for the driver. The resonator of the driver laser consists of a plane grating of littrow arrangement and ZnSe plane output mirrors with reflection factor of 50 %. An aperture and ZnSe etalon are inserted in the resonator to produce single transverse- and longitudinal-mode oscillation, respectively. The output-stage laser is also of the automatic pre-ionization type. Theoretically, an injection power of 0.1 pW/mm 3 is required for a CO 2 laser. Single-mode oscillation of several hundred nW/mm 3 can be produced by the CO 2 laser used in this study. Tuning of the output-stage laser is easily controlled by the driver laser. High stability of the injection-locked operation is demonstrated. CO 2 laser beam is introduced into the D 2 O laser through a KCl window to excite D 2 O laser beam in the axial direction. Input and output characteristics of the D 2 O laser are shown. Also presented are typical pulse shapes from the D 2 O laser pumped by a free-running CO 2 laser pulse or by an injection-locked single-mode CO 2 laser pulse. (Nogami, K.)

  15. Expression kinetics of nucleoside-modified mRNA delivered in lipid nanoparticles to mice by various routes.

    Science.gov (United States)

    Pardi, Norbert; Tuyishime, Steven; Muramatsu, Hiromi; Kariko, Katalin; Mui, Barbara L; Tam, Ying K; Madden, Thomas D; Hope, Michael J; Weissman, Drew

    2015-11-10

    In recent years, in vitro transcribed messenger RNA (mRNA) has emerged as a potential therapeutic platform. To fulfill its promise, effective delivery of mRNA to specific cell types and tissues needs to be achieved. Lipid nanoparticles (LNPs) are efficient carriers for short-interfering RNAs and have entered clinical trials. However, little is known about the potential of LNPs to deliver mRNA. Here, we generated mRNA-LNPs by incorporating HPLC purified, 1-methylpseudouridine-containing mRNA comprising codon-optimized firefly luciferase into stable LNPs. Mice were injected with 0.005-0.250mg/kg doses of mRNA-LNPs by 6 different routes and high levels of protein translation could be measured using in vivo imaging. Subcutaneous, intramuscular and intradermal injection of the LNP-encapsulated mRNA translated locally at the site of injection for up to 10days. For several days, high levels of protein production could be achieved in the lung from the intratracheal administration of mRNA. Intravenous and intraperitoneal and to a lesser extent intramuscular and intratracheal deliveries led to trafficking of mRNA-LNPs systemically resulting in active translation of the mRNA in the liver for 1-4 days. Our results demonstrate that LNPs are appropriate carriers for mRNA in vivo and have the potential to become valuable tools for delivering mRNA encoding therapeutic proteins. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Clinical and histological findings after intravitreal injection of bevacizumab (Avastin) in a porcine model of choroidal neovascularization

    DEFF Research Database (Denmark)

    Lassota, Nathan; Prause, Jan Ulrik; Scherfig, Erik

    2010-01-01

    PURPOSE: To examine the effect of intravitreally injected bevacizumab (Avastin) on the histological and angiographic morphology of choroidal neovascularization (CNV) in a masked and placebo-controlled animal study. METHODS: Choroidal neovascularization was induced surgically in 11 porcine eyes by...... these membranes. After a single injection, bevacizumab did not exhibit a size reducing effect on CNV, but it was still present in the membranes 14 days after intravitreal injection....

  17. Compressed air injection technique to standardize block injection pressures.

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes (18G, 20G, 21G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed.

  18. Injection locking of optomechanical oscillators via acoustic waves

    Science.gov (United States)

    Huang, Ke; Hossein-Zadeh, Mani

    2018-04-01

    Injection locking is a powerful technique for synchronization of oscillator networks and controlling the phase and frequency of individual oscillators using similar or other types of oscillators. Here, we present the first demonstration of injection locking of a radiation-pressure driven optomechanical oscillator (OMO) via acoustic waves. As opposed to previously reported techniques (based on pump modulation or direct application of a modulated electrostatic force), injection locking of OMO via acoustic waves does not require optical power modulation or physical contact with the OMO and it can easily be implemented on various platforms. Using this approach we have locked the phase and frequency of two distinct modes of a microtoroidal silica OMO to a piezoelectric transducer (PZT). We have characterized the behavior of the injection locked OMO with three acoustic excitation configurations and showed that even without proper acoustic impedance matching the OMO can be locked to the PZT and tuned over 17 kHz with only -30 dBm of RF power fed to the PZT. The high efficiency, simplicity and scalability of the proposed approach paves the road toward a new class of photonic systems that rely on synchronization of several OMOs to a single or multiple RF oscillators with applications in optical communication, metrology and sensing. Beyond its practical applications, injection locking via acoustic waves can be used in fundamental studies in quantum optomechanics where thermal and optical isolation of the OMO are critical.

  19. Dynamic renal and static bone imaging after a single foot injection of Tc-99m methylene diphosphonate

    International Nuclear Information System (INIS)

    Siddiqui, A.R.; Cohen, M.; Moran, D.P.

    1982-01-01

    Much better information regarding the renal anatomy and physiology can be obtained by imaging the kidneys immediately after the injection of Tc-99m MDP, rather than on the bone scan a few hours later. Evaluation of inferior vena cava is possible if the radiotracer is injected in the foot and dynamic images of the abdomen are obtained. It is possible to differentiate renal from extra-renal masses during bone scanning without any additional radiation to the patient

  20. "Injection first": a unique group of injection drug users in Tijuana, Mexico.

    Science.gov (United States)

    Morris, Meghan D; Brouwer, Kimberly C; Lozada, Remedios M; Gallardo, Manuel; Vera, Alicia; Strathdee, Steffanie A

    2012-01-01

    Using baseline data from a study of injection drug users (IDUs) in Tijuana, Mexico (N = 1,052), we identified social and behavioral factors associated with injecting at the same age or earlier than other administration routes of illicit drug use (eg, "injection first") and examined whether this IDU subgroup had riskier drug using and sexual behaviors than other IDUs. Twelve-percent "injected first." Characteristics independently associated with a higher odds of "injection first" included being younger at first injection, injecting heroin as their first drug, being alone at the first injection episode, and having a sexual debut at the same age or earlier as when they initiated drug use; family members' illicit drug use was associated with lower odds of injecting first. When adjusting for age at first injection and number of years injecting, "injection first" IDUs had lower odds of ever overdosing, and ever trading sex. On the other hand, they were less likely to have ever been enrolled in drug treatment, and more commonly obtained their syringes from potentially unsafe sources. In conclusion, a sizable proportion of IDUs in Tijuana injected as their first drug using experience, although evidence that this was a riskier subgroup of IDUs was inconclusive.  Copyright © American Academy of Addiction Psychiatry.

  1. Can repeat injection provide clinical benefit in patients with cervical disc herniation and stenosis when the first epidural injection results only in partial response?

    Science.gov (United States)

    Lee, Jung Hwan; Lee, Sang-Ho

    2016-07-01

    Epidural steroid injection (ESI) is known to be an effective treatment for neck or radicular pain due to herniated intervertebral disc (HIVD) and spinal stenosis (SS). Although repeat ESI has generally been indicated to provide more pain relief in partial responders after single ESI, there has been little evidence supporting the usefulness of this procedure. The purpose of this study, therefore, was to determine whether repeat ESI at a prescribed interval of 2 to 3 weeks after the first injection would provide greater clinical benefit in patients with partial pain reduction than intermittent ESI performed only when pain was aggravated. One hundred eighty-four patients who underwent transforaminal ESI (TFESI) for treatment of axial neck and radicular arm pain due to HIVD or SS and could be followed up for 1 year were enrolled. We divided the patients into 2 groups. Group A (N = 108) comprised partial responders (numeric rating scale (NRS) ≥ 3 after the first injection) who underwent repeat injection at a prescribed interval of 2 to 3 weeks after the first injection. Group B (N = 76) comprised partial responders who did not receive repeat injection at the prescribed interval, but received intermittent injections only for aggravation of pain. Various clinical data were assessed, including total number of injections during 1 year, NRS duration of Group A, or after first injection in Group B (time to reinjection). Groups A and B were compared in terms of total population, HIVD, and SS. In the whole population, HIVD subgroup, and SS subgroup, patients in Group A required significantly fewer injections to obtain satisfactory pain relief during the 1-year follow-up period. Group A showed a significantly longer time to reinjection and longer NRS Group B did. Repeat TFESI conducted at 2- to 3-week intervals after the first injection in partial responders contributed to greater clinical benefit compared with intermittent TFESI performed only upon pain

  2. Determination of the Tissue Distribution and Excretion by Accelerator Mass Spectrometry of the Nonadecapeptide 14C-Moli1901 in Beagle dogs after Intratracheal Instillation

    Energy Technology Data Exchange (ETDEWEB)

    Rickert, D E; Dingley, K H; Ubick, E; Dix, K J; Molina, L

    2004-07-02

    Administration of {sup 14}C-Moli1901 (duramycin, 2622U90), a 19 amino acid polycyclic peptide by intratracheal instillation (approximately 100 {micro}g) into the left cranial lobe of the lung of beagle dogs resulted in retention of 64% of the dose in the left cranial lobe for up to 28 days. In this study, we used accelerator mass spectrometry (AMS) to quantify Moli901 following administration of only 0.045 {micro}Ci of {sup 14}C-Moli901 per dog. Limits of quantitation of AMS were 0.03 (urine) to 0.3 (feces) ng equiv. Moli1901/g. Whole blood and plasma concentrations of {sup 14}C were <5ng/ml at all times after the dose. Concentrations of {sup 14}C in whole blood and plasma declined over the first day after the dose and rose thereafter, with the rise in plasma concentrations lagging behind those in whole blood. During the first 3 days after the dose, plasma accounted for the majority of {sup 14}C in whole blood, but after that time, plasma accounted for only 25-30% of the {sup 14}C in whole blood. Tissue (left and right caudal lung lobe, liver, kidney, spleen, brain) and bile concentrations were low, always less than 0.25% the concentrations found in the left cranial lung lobe. Approximately 13% of the dose was eliminated in urine and feces in 28 days, with fecal elimination accounting for about 10% of the dose. The data presented here are consistent with that obtained in other species. Moli1901 is slowly absorbed and excreted from the lung, and it does not accumulate in other tissues. Moli1901 is currently in the clinic and has proven to be safe in single dose studies in human volunteers and cystic fibrosis patients by the inhalation route. No information on the disposition of the compound in humans is available. This study in dogs demonstrates the feasibility of obtaining that information using {sup 14}C-Moli1901 and AMS.

  3. Comparison of single-injection ultrasound-guided approach versus multilevel landmark-based approach for thoracic paravertebral blockade for breast tumor resection: a retrospective analysis at a tertiary care teaching institution

    Directory of Open Access Journals (Sweden)

    Saran JS

    2017-06-01

    Full Text Available Jagroop Singh Saran,1 Amie L Hoefnagel,1 Kristin A Skinner,2 Changyong Feng,3 Daryl Irving Smith1 1Acute Pain Service, Department of Anesthesiology, University of Rochester School of Medicine and Dentistry, 2Department of Surgical Oncology, University of Rochester School of Medicine and Dentistry, University of Rochester Medical Center, 3Department of Biostatistics and Computational Biology, University of Rochester School of Medicine and Dentistry, Rochester, NY, USA Background: The role of thoracic paravertebral blockade (TPVB in decreasing opioid requirements in breast cancer surgery is well documented, and there is mounting evidence that this may improve survival and reduce the rate of malignancy recurrence following cancer-related mastectomy. We compared the two techniques currently in use at our institution, the anatomic landmark-guided (ALG multilevel versus an ultrasound-guided (USG single injection, to determine an optimal technique.Methods: We retrospectively reviewed records of patients who received TPVB from January 2013 to December 2014. Perioperative opioid use, post anesthesia care unit (PACU pain scores and length of stay, block performance, and complications were compared between the two groups.Results: We found no statistical difference between the two approaches in the studied outcomes. We did find that the number of times attending physicians in the ALG group took over the blocks from residents was significantly greater than that of the USG group (p=0.006 and more local anesthetic was used in the USG group (p=0.04.Conclusion: This study compared the ALG approach with the USG approach for patients undergoing mastectomy for breast cancer. Based on our observations, an attending physician is more likely to take over an ALG injection, and more local anesthetic is administered during USG single injection. Keywords: thoracic paravertebral block, regional anesthesia, mastectomy, breast cancer 

  4. VLF wave injections from the ground

    Science.gov (United States)

    Helliwell, R. A.

    1983-01-01

    Experiments on wave-particle interactions using VLF whistler-mode waves injected into the magnetosphere from Antartica are described. The injected signals are single-frequency coherent waves whose amplitudes and frequencies may be changed slowly with time, or else two or more coherent wave trains transmitted simultaneously to determine the nature of the response to multifrequency excitation. The waves may be amplified 30 dB or more and may trigger intense emissions having bandwidths that vary from a few to several hundred Hertz. In most cases significant growth and triggering occur only when the driving signal is essentially monochromatic (bandwidth 10 Hz). If two frequencies are transmitted simultaneously the signal at the lower frequency tends to be suppressed by 20 dB or more. These results are interpreted in terms of a feedback interaction between the waves and counter-streaming cyclotron resonant electrons in a region several hundred wavelengths long, centered on the magnetic equator.

  5. Thermorespiratory Response of West African Dwarf Does to Progestagen Injection

    Directory of Open Access Journals (Sweden)

    Ogundana, FA.

    2005-01-01

    Full Text Available The physiological responses in terms of respiration rate (RR and rectal temperature (RT of 30 West African Dwarf (WAD does were monitored after a single im injection of different doses of progestagens meant for synchronising oestrus. The treatments involved im injection of 1 2 ml of sterile water (Control; 2 25 mg Medroxy Progesterone Acetate, MPA; 3 50 mg MPA; 4 50 mg Progesterone and 5 100 mg progesterone. The RR and RT of each animal were measured at 9:00, 13:00 and 17:00 h for 21 days after each injection. In all the treatment groups the RT did not change significantly (P> 0.05 during the weeks following treatment. On the contrary the RR was significantly higher (P< 0.05 in the week after injection than in the pre-injection period. Both the RR and the RT were higher at 13:00 h and 17:00 h than at 9:00 h. The RR was more influenced by the animal body size than the RT, while the ambient temperature and humidity affected both the animal's RT and RR. These results indicate that the thermorespiratory function of WAD does under their native humid environment is not negatively affected by injecting ≤ 100 mg progesterone or ≤ 50 mg MPA to synchronize oestrus.

  6. Potential benefits of saturation cycle with two-phase refrigerant injection

    International Nuclear Information System (INIS)

    Lee, Hoseong; Hwang, Yunho; Radermacher, Reinhard; Chun, Ho-Hwan

    2013-01-01

    In this paper, a saturation cycle is proposed to enhance a vapor compression cycle performance by reducing thermodynamic losses associated with single phase gas compression and isenthalpic expansion. In order to approach the saturation cycle, a two-phase refrigerant injection technique is applied to the multi-stage cycle. This multi-stage cycle with different options is modeled, and its performance is evaluated under ASHRAE standard operating conditions for air conditioning systems. Moreover, the two-phase refrigerant injection cycle is compared with the typical vapor injection cycle which is utilizing the internal heat exchanger or the flash tank. Low GWP refrigerants are applied to this two-phase refrigerant injection cycle. In terms of the COP and its improvement, R123 has a higher potential than any other refrigerants in the multi-stage cycle. Lastly, practical ideas realizing the saturation cycle are discussed such as multi-stage phase separator, phase separator with helical structure inside, and injection location of the compressor. -- Highlights: • A saturation cycle is proposed to enhance the vapor compression cycle performance. • Two-phase refrigerant injection technique is applied to the multi-stage cycle. • Modeling results of the proposed cycle show the significant performance improvement. • Low GWP refrigerants are applied and R123 shows the highest performance. • New parameters, α and ε, are used to show the potential of the saturation cycle

  7. A prospective, randomized, single - blind study comparing intraplaque injection of thiocolchicine and verapamil in Peyronie's Disease: a pilot study

    Directory of Open Access Journals (Sweden)

    I. L. Toscano Jr.

    Full Text Available ABSTRACT Objectives: To compare the response to tiocolchicine and verapamil injection in the plaque of patients with Peyronie's disease. Materials and Methods: Prospective, single-blind, randomized study, selecting patients who have presented Peyronie's disease for less than 18 months. Thiocolchicine 4mg or verapamil 5mg were given in 7 injections (once a week. Patients who had received any treatment for Peyronie's disease in the past three months were excluded. The parameters used were the International Index of Erectile Function (IIEF-5 score, analysis of the curvature on pharmaco-induced erections and size of the plaque by ultrasonography. Results: Twenty-five patients were randomized, 13 received thiocolchicine and 12 were treated with verapamil. Both groups were statistically similar. The mean curvature was 46.7° and 36.2° before and after thiocolchicine, respectively (p=0.019 and 50.4° and 42.08° before and after verapamil, respectively (p=0.012. The curvature improved in 69% of patients treated with thiocolchicine and in 66% of those who received verapamil. Regarding sexual function, there was an increase in the IIEF-5 from 16.69 to 20.85 (p=0.23 in the thiocolchicine group. In the verapamil group the IIEF-5 score dropped from 17.50 to 16.25 (p=0.58. In the thiocolchicine group, the plaque was reduced in 61% of patients. In the verapamil group, 8% presented decreased plaque size. No adverse event was associated to thiocolchicine. Conclusion: The use of thiocolchicine in Peyronie's disease demonstrated improvement on penile curvature and reduction in plaque size. Thiocolchicine presented similar results to verapamil in curvature assessment. No significant side effects were observed with the use of tiocolchicine.

  8. Safe injection procedures, injection practices, and needlestick ...

    African Journals Online (AJOL)

    Nermine Mohamed Tawfik Foda

    2017-01-10

    Jan 10, 2017 ... Background: Of the estimated 384,000 needle-stick injuries occurring in hospitals each year, 23% occur in surgical settings. This study was conducted to assess safe injection procedures, injection practices, and circumstances contributing to needlestick and sharps injures (NSSIs) in operating rooms.

  9. Injection Locking of a Semiconductor Double Quantum Dot Micromaser.

    Science.gov (United States)

    Liu, Y-Y; Stehlik, J; Gullans, M J; Taylor, J M; Petta, J R

    2015-11-01

    Emission linewidth is an important figure of merit for masers and lasers. We recently demonstrated a semiconductor double quantum dot (DQD) micromaser where photons are generated through single electron tunneling events. Charge noise directly couples to the DQD energy levels, resulting in a maser linewidth that is more than 100 times larger than the Schawlow-Townes prediction. Here we demonstrate a linewidth narrowing of more than a factor 10 by locking the DQD emission to a coherent tone that is injected to the input port of the cavity. We measure the injection locking range as a function of cavity input power and show that it is in agreement with the Adler equation. The position and amplitude of distortion sidebands that appear outside of the injection locking range are quantitatively examined. Our results show that this unconventional maser, which is impacted by strong charge noise and electron-phonon coupling, is well described by standard laser models.

  10. 2D temperature field measurement in a direct-injection engine using LIF technology

    Science.gov (United States)

    Liu, Yongfeng; Tian, Hongsen; Yang, Jianwei; Sun, Jianmin; Zhu, Aihua

    2011-12-01

    A new multi-spectral detection strategy for temperature laser- induced- fluorescence (LIF) 2-D imaging measurements is reported for high pressure flames in high-speed diesel engine. Schematic of the experimental set-up is outlined and the experimental data on the diesel engine is summarized. Experiment injection system is a third generation Bosch high-pressure common rail featuring a maximum pressure of 160MPa. The injector is equipped with a six-hole nozzle, where each hole has a diameter of 0.124 mm. and slightly offset to the center of the cylinder axis to allow a better cooling of the narrow bridge between the exhaust valves. The measurement system includes a blower, which supplied the intake flow rate, and a prototype single-valve direct injection diesel engine head modified to lay down the swirled-type injector. 14-bit digital CCD cameras are employed to achieve a greater level of accuracy in comparison to the results of previous measurements. The temperature field spatial distributions in the cylinder for different crank angle degrees are carried out in a single direct-injection diesel engine.

  11. Direct-injection strategies for a hydrogen-fueled engine : an optical and numerical investigation

    Energy Technology Data Exchange (ETDEWEB)

    Kaiser, S.; Salazar, V. [Sandia National Labs, Albuquerque, NM (United States); Scarcelli, R.; Wallner, T. [Argonne National Lab, Argonne, IL (United States)

    2009-07-01

    Vehicles with hydrogen-fueled engines are competitive with systems based on fuel cells. There is a lack of fundamental knowledge about in-cylinder processes in hydrogen direct injection engines. This presentation discussed a study that used a variety of injector configurations to establish a broad database. A light-load conditions that can profit from stratification was investigated. Several results were presented, including the 5-hole nozzle produced an asymmetric jet pattern which may be good for late injection. Very lean regions in the wake of the transient jets were found to be similar to those found in diesel injection. The 13-hole nozzle demonstrated complete jet collapse, consistent with Schlieren imaging by Petersen. Stratification made efficiency sensitive to the targeting of the single-hole injector. Computational fluid dynamics with a commercially available code aimed to improve the process of design optimization. The simulation predicted less fuel dispersion than was experimentally measured. Details of the fuel penetration were captured. It was concluded that for the single-hole nozzle, the pre-spark fuel distribution is consistent with results from the fired engine. tabs., figs.

  12. A Three-arm Randomized Clinical Trial Comparing Continuous Femoral Plus Single-injection Sciatic Peripheral Nerve Blocks versus Periarticular Injection with Ropivacaine or Liposomal Bupivacaine for Patients Undergoing Total Knee Arthroplasty.

    Science.gov (United States)

    Amundson, Adam W; Johnson, Rebecca L; Abdel, Matthew P; Mantilla, Carlos B; Panchamia, Jason K; Taunton, Michael J; Kralovec, Michael E; Hebl, James R; Schroeder, Darrell R; Pagnano, Mark W; Kopp, Sandra L

    2017-06-01

    Multimodal analgesia is standard practice for total knee arthroplasty; however, the role of regional techniques in improved perioperative outcomes remains unknown. The authors hypothesized that peripheral nerve blockade would result in lower pain scores and opioid consumption than two competing periarticular injection solutions. This three-arm, nonblinded trial randomized 165 adults undergoing unilateral primary total knee arthroplasty to receive (1) femoral catheter plus sciatic nerve blocks, (2) ropivacaine-based periarticular injection, or (3) liposomal bupivacaine-based periarticular injection. Primary outcome was maximal pain during postoperative day 1 (0 to 10, numerical pain rating scale) in intention-to-treat analysis. Additional outcomes included pain scores and opioid consumption for postoperative days 0 to 2 and 3 months. One hundred fifty-seven study patients received peripheral nerve block (n = 50), ropivacaine (n = 55), or liposomal bupivacaine (n = 52) and reported median maximal pain scores on postoperative day 1 of 3, 4, and 4.5 and on postoperative day 0 of 1, 4, and 5, respectively (average pain scores for postoperative day 0: 0.6, 1.7, and 2.4 and postoperative day 1: 2.5, 3.5, and 3.7). Postoperative day 1 median maximal pain scores were significantly lower for peripheral nerve blockade compared to liposomal bupivacaine-based periarticular injection (P = 0.016; Hodges-Lehmann median difference [95% CI] = -1 [-2 to 0]). After postanesthesia care unit discharge, postoperative day 0 median maximal and average pain scores were significantly lower for peripheral nerve block compared to both periarticular injections (ropivacaine: maximal -2 [-3 to -1]; P bupivacaine: maximal -3 [-4 to -2]; P bupivacaine over ropivacaine in periarticular injections for total knee arthroplasty.

  13. Steroid injection for shoulder pain causes prolonged increased glucose level in type 1 diabetics.

    Science.gov (United States)

    Povlsen, Bo; Povlsen, Sebastian D

    2014-09-08

    Shoulder pain is very common in diabetic patients and often treated with steroid injections, with subsequent increases in blood glucose levels or the need for additional insulin being questioned. We report a case of significant and prolonged elevation of blood glucose levels and resultant insulin requirement in a type 1 diabetic man after a single 40 mg injection of triamcinolone for shoulder pain. Within 48 h, the shoulder pain as assessed by a visual analogue scale (0-10) was reduced to zero, but the elevated insulin requirements continued for 4 weeks after the injection. This finding suggests that steroid injections for shoulder pain in diabetics may not always be as safe as previously thought. We propose that medical practitioners advise their patients to monitor their glucose levels more carefully after such injections and that caution is exercised when considering administrating these injections to those who have poorly controlled blood glucose levels preinjection to avoid ketoacidosis. 2014 BMJ Publishing Group Ltd.

  14. An analysis of direct-injection spark-ignition (DISI) soot morphology

    Science.gov (United States)

    Barone, Teresa L.; Storey, John M. E.; Youngquist, Adam D.; Szybist, James P.

    2012-03-01

    We have characterized particle emissions produced by a 4-cylinder, 2.0 L DISI engine using transmission electron microscopy (TEM) and image analysis. Analyses of soot morphology provide insight to particle formation mechanisms and strategies for prevention. Particle emissions generated by two fueling strategies were investigated, early injection and injection modified for low particle number concentration emissions. A blend of 20% ethanol and 80% emissions certification gasoline was used for the study given the likelihood of increased ethanol content in widely available fuel. In total, about 200 particles and 3000 primary soot spherules were individually measured. For the fuel injection strategy which produced low particle number concentration emissions, we found a prevalence of single solid sub-25 nm particles and fractal-like aggregates. The modal diameter of single solid particles and aggregate primary particles was between 10 and 15 nm. Solid particles as small as 6 nm were present. Although nanoparticle aggregates had fractal-like morphology similar to diesel soot, the average primary particle diameter per aggregate had a much wider range that spanned from 7 to 60 nm. For the early fuel injection strategy, liquid droplets were prevalent, and the modal average primary particle diameter was between 20 and 25 nm. The presence of liquid droplets may have been the result of unburned fuel and/or lubricating oil originating from fuel impingement on the piston or cylinder wall; the larger modal aggregate primary particle diameter suggests greater fuel-rich zones in-cylinder than for the low particle number concentration point. However, both conditions produced aggregates with a wide range of primary particle diameters, which indicates heterogeneous fuel and air mixing.

  15. Emission, efficiency, and influence in a diesel n-butanol dual-injection engine

    International Nuclear Information System (INIS)

    Zhu, Yanchun; Chen, Zheng; Liu, Jingping

    2014-01-01

    Highlights: • Dual-injection combustion for diesel n-butanol dual-fuel is investigated. • Higher EGR rate results in lower NOx and ITE, but higher smoke, HC and CO. • Larger butanol fraction results in lower smoke and ITE, but higher NOx, HC and CO. • Advanced injection can decrease smoke, HC and CO, and increase ITE. • Coupling of butanol fraction, EGR and injection timing makes for a better performance. - Abstract: In this work, a dual-injection combustion mode for diesel n-butanol dual-fuel, combined direct injection (DI) of diesel with port fuel injection (PFI) of n-butanol, was introduced. Effects of n-butanol fraction, EGR rate and injection timing on this mode were studied on a modified single-cylinder diesel engine at the speed of 1400 r/min and the IMEP of 1.0 MPa. The results indicate that with increased EGR rate, NOx emissions reduce, but smoke emissions increase. As n-butanol fraction is increased, smoke emissions decrease with a small increase in NOx. However, higher HC and CO emissions, higher indicated specific fuel consumption (ISFC) and lower indicated thermal efficiency (ITE) have to be paid with increased n-butanol fraction, especially at high EGR condition. Advancing diesel injection timing suitably has the capacity of mitigating those costs and further decreasing smoke emissions with a small penalty in NOx emissions. Coupling of large butanol fraction, high EGR rate, and advanced injection suitably contributes to a better balance between emissions and efficiency in the diesel n-butanol dual-injection engine

  16. Successful Treatment of Retinal Angiomatous Proliferation with Intravitreal Triamcinolone and Ranibizumab Injections in a 67-Year-Old Male

    Directory of Open Access Journals (Sweden)

    Adnaan Haq

    2014-11-01

    Full Text Available A 67-year-old male who presented to the eye casualty department with deterioration in his vision was diagnosed with retinal angiomatous proliferation. After initial deterioration with ranibizumab intravitreal injections, we have demonstrated successful treatment and stabilised vision with ranibizumab and a single intravitreal triamcinolone injection. Stringent follow-up and top-up ranibizumab injections have stabilised his vision and have shown foveal improvement on optical coherence tomography imaging.

  17. Mathematical modeling of flow-injection techniques and their applications for environmental monitoring

    International Nuclear Information System (INIS)

    Begum, N.N.; Ahmed, J.

    2006-01-01

    A classification of the existing mathematical models of flow-injection (FI) manifolds based on the main principles on which they are built, have been proposed. Numerous mathematical models of FI systems employing ideas from different scientific areas (e.g. mathematical statistics, chemical engineering, chromatography) have been developed so far. The models have been compared with respect to their predictive power, the complexity of their mathematical treatment, and the requirements for computation time when applied to single-line, multi-channel and conjugated two-line FI systems. It is concluded that the axially dispersed plug flow model deserves special attention because it offers an acceptable compromise between the conflicting requirements for maximal possible mathematical simplicity and maximal possible precision. Applicability of these existing flow-injection models to single-line, multi-channel and conjugated two-line systems for environmental monitoring have been discussed. (author)

  18. Accelerated avascular necrosis after single intra-articular injection of corticosteroid into the hip joint

    OpenAIRE

    Kassam, A M

    2010-01-01

    Avascular necrosis (AVN) involves destruction of the hip joint. Long-term use of steroids has been shown to cause AVN. This article presents a case of intra-articular injection of steroid causing a rapid onset of AVN in the hip joint. Bone histology at time of total hip replacement showed evidence of AVN and no evidence of infection.

  19. Exploiting the bead-injection approach in the integrated sequential injection Lab-on-Valve format using hydrophobic packing materials for on-line matrix removal and preconcentration of trace levels of cadmium in environmental and biological samples via formation of non-charged chelates prior

    DEFF Research Database (Denmark)

    Miró, Manuel; Jonczyk, Sylwia; Wang, Jianhua

    2003-01-01

    The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption spectrome......The concept of renewable microcolumns within the conduits of an automated single injection lab-on-valve system was exploited in a sorption/elution fashion using sorbents of hydrophobic nature. The scheme's practical applicability was demonstrated for the electrothermal atomic absorption...

  20. Effect of exhaust gas recirculation (EGR) and multiple injections on diesel soot nano-structure and reactivity

    International Nuclear Information System (INIS)

    Rohani, Behzad; Bae, Choongsik

    2017-01-01

    Highlights: • EGR reduced the nano-structural order, regardless of injection strategy. • EGR reduces both VOF and reactivity, regardless of injection strategy. • Longer dwell time between pilot and main injection increases VOF and reactivity. • With EGR, VOF and reactivity are both reduced and un-affected by injection strategy. • VOF-reactivity correlation (without causality) suggests role of surface roughness. - Abstract: The physio-chemical characteristics of soot particles are of importance with regard to performance of diesel after-treatment systems. In this study, the soot particles generated in a single-cylinder heavy-duty diesel engine are examined in terms of nanostructure, oxidative reactivity and volatile organic fraction (VOF), using thermogravimetric analysis (TGA), X-ray diffraction (XRD), Raman micro-spectroscopy, and high resolution transmission electron microscopy (HRTEM). Five different injection strategies including single injection and multiple injections with various pilot injection amounts and dwell times were tested with and without exhaust gas recirculation (EGR), while combustion phasing, engine speed, and fuel injection quantity was matched for all cases. Results indicate that for the soot produced under EGR condition, nano-structural order (indicated by crystallite size obtained from XRD and AD1/AG resulted from the Raman Analysis) can explain the soot reactivity. However, in the absence of EGR, the reactivity trend cannot be explained by the structural order. It is discussed that a possible reason can be a higher level of in-cylinder oxidation in non-EGR cases (indicated by higher level of surface functional groups) which roughens the soot surface, and enhances the oxidation by increasing the specific soot surface area. It is also found that in the absence of EGR, different injection strategies impact the soot reactivity and VOF content, which can be explained mainly through the level of charge premixed-ness and the in

  1. Dual isotope, single acquisition parathyroid imaging

    International Nuclear Information System (INIS)

    Triantafillou, M.; McDonald, H.J.

    1998-01-01

    Full text: Nuclear Medicine parathyroid imaging using Thallium-201(TI) and Technetium-99m(Tc) is an often used imaging modality for the detection of parathyroid adenomas and hyper parathyroidism. The conventional Tl/Tc subtraction technique requires 2 separate injections and acquisitions which are then normalised and subtracted from each other. This lengthy technique is uncomfortable for patients and can result in false positive scan results due to patient movement between and during the acquisition process. We propose a simplified injection and single acquisition technique, that reduces the chance of movement and thus reduces the chance of false positive scan results. The technique involves the injection of Tc followed by the Tl injection 10 minutes later. After a further 10 min wait, imaging is performed using a dual isotope acquisition, with window (W) 1 set on 140 keV 20%W 5% off peak and W2 peaked for 70 keV 20%W., acquired for 10 minutes. We have imaged 27 patients with this technique, 15 had positive parathyroid imaging. Of the 15, 11 had positive ultrasound correlation. Of the remaining 4, 2 have had positive surgical findings for adenomas, the other 2 are awaiting follow-up. Of the 12 patients with negative parathyroid imaging, 2 have been shown to be false - negative with surgery. In conclusion, the single acquisition technique suggested by us is a valid method of imaging parathyroids that reduces the chance of false positive results due to movement

  2. Diagnostic value of lumbar facet joint injection: a prospective triple cross-over study.

    Directory of Open Access Journals (Sweden)

    Uwe Schütz

    Full Text Available The diagnosis "lumbar facet syndrome" is common and often indicates severe lumbar spine surgery procedures. It is doubtful whether a painful facet joint (FJ can be identified by a single FJ block. The aim of this study was to clarify the validity of a single and placebo controlled bilateral FJ blocks using local anesthetics. A prospective single blinded triple cross-over study was performed. 60 patients (31 f, 29 m, mean age 53.2 yrs (22-73 with chronic low back pain (mean pain persistance 31 months, 6 months of conservative treatment without success admitted to a local orthopaedic department for surgical or conservative therapy of chronic LBP, were included in the study. Effect on pain reduction (10 point rating scale was measured. The 60 subjects were divided into six groups with three defined sequences of fluoroscopically guided bilateral monosegmental lumbar FJ test injections in "oblique needle" technique: verum-(local anaesthetic-, placebo-(sodium chloride- and sham-injection. Carry-over and periodic effects were evaluated and a descriptive and statistical analysis regarding the effectiveness, difference and equality of the FJ injections and the different responses was performed. The results show a high rate of non-response, which documents the lack of reliable and valid predictors for a positive response towards FJ blocks. There was a high rate of placebo reactions noted, including subjects who previously or later reacted positively to verum injections. Equivalence was shown among verum vs. placebo and partly vs. sham also. With regard to test validity criteria, a single intraarticular FJ block with local anesthetics is not useful to detect the pain-responsible FJ and therefore is no valid and reliable diagostic tool to specify indication of lumbar spine surgery. Comparative FJ blocks with local anesthetics and placebo-controls have to be interpretated carefully also, because they solely give no proper diagnosis on FJ being main pain

  3. Small-Volume Injections: Evaluation of Volume Administration Deviation From Intended Injection Volumes.

    Science.gov (United States)

    Muffly, Matthew K; Chen, Michael I; Claure, Rebecca E; Drover, David R; Efron, Bradley; Fitch, William L; Hammer, Gregory B

    2017-10-01

    In the perioperative period, anesthesiologists and postanesthesia care unit (PACU) nurses routinely prepare and administer small-volume IV injections, yet the accuracy of delivered medication volumes in this setting has not been described. In this ex vivo study, we sought to characterize the degree to which small-volume injections (≤0.5 mL) deviated from the intended injection volumes among a group of pediatric anesthesiologists and pediatric postanesthesia care unit (PACU) nurses. We hypothesized that as the intended injection volumes decreased, the deviation from those intended injection volumes would increase. Ten attending pediatric anesthesiologists and 10 pediatric PACU nurses each performed a series of 10 injections into a simulated patient IV setup. Practitioners used separate 1-mL tuberculin syringes with removable 18-gauge needles (Becton-Dickinson & Company, Franklin Lakes, NJ) to aspirate 5 different volumes (0.025, 0.05, 0.1, 0.25, and 0.5 mL) of 0.25 mM Lucifer Yellow (LY) fluorescent dye constituted in saline (Sigma Aldrich, St. Louis, MO) from a rubber-stoppered vial. Each participant then injected the specified volume of LY fluorescent dye via a 3-way stopcock into IV tubing with free-flowing 0.9% sodium chloride (10 mL/min). The injected volume of LY fluorescent dye and 0.9% sodium chloride then drained into a collection vial for laboratory analysis. Microplate fluorescence wavelength detection (Infinite M1000; Tecan, Mannedorf, Switzerland) was used to measure the fluorescence of the collected fluid. Administered injection volumes were calculated based on the fluorescence of the collected fluid using a calibration curve of known LY volumes and associated fluorescence.To determine whether deviation of the administered volumes from the intended injection volumes increased at lower injection volumes, we compared the proportional injection volume error (loge [administered volume/intended volume]) for each of the 5 injection volumes using a linear

  4. Increasing the effectiveness of intracerebral injections in adult and neonatal mice: a neurosurgical point of view.

    Science.gov (United States)

    Mathon, Bertrand; Nassar, Mérie; Simonnet, Jean; Le Duigou, Caroline; Clemenceau, Stéphane; Miles, Richard; Fricker, Desdemona

    2015-12-01

    Intracerebral injections of tracers or viral constructs in rodents are now commonly used in the neurosciences and must be executed perfectly. The purpose of this article is to update existing protocols for intracerebral injections in adult and neonatal mice. Our procedure for stereotaxic injections in adult mice allows the investigator to improve the effectiveness and safety, and save time. Furthermore, for the first time, we describe a two-handed procedure for intracerebral injections in neonatal mice that can be performed by a single operator in a very short time. Our technique using the stereotaxic arm allows a higher precision than freehand techniques previously described. Stereotaxic injections in adult mice can be performed in 20 min and have >90% efficacy in targeting the injection site. Injections in neonatal mice can be performed in 5 min. Efficacy depends on the difficulty of precisely localizing the injection sites, due to the small size of the animal. We describe an innovative, effortless, and reproducible surgical protocol for intracerebral injections in adult and neonatal mice.

  5. Can Repeat Injection Provide Clinical Benefit in Patients with Lumbosacral Diseases When First Epidural Injection Results Only in Partial Response?

    Science.gov (United States)

    Lee, Jung Hwan; Lee, Sang-Ho

    2016-02-01

    Epidural steroid injection (ESI) is known to be an effective treatment for lower back or radicular pain due to herniated intervertebral disc (HIVD) and spinal stenosis (SS). Although repeat ESI has generally been indicated to provide more pain relief in partial responders after a single ESI, there has been little evidence supporting the usefulness of repeat injections in cumulative clinical pain reduction. The purpose of this study was to determine whether repeat ESI at a prescribed interval of 2 to 3 weeks after the first injection would provide greater clinical benefit in patients with partial pain reduction than that provided by intermittent injection performed only when pain was aggravated. An Institutional Review Board (IRB)-approved retrospective chart review. Spine hospital. Two hundred and four patients who had underwent transforaminal ESI (TFESI) for treatment of lower back and radicular pain due to HIVD or SS and could be followed-up for one year were enrolled. We divided the patients into 2 groups. Group A (N = 108) comprised partial responders (NRS = 3 after first injection) who underwent repeat injection at a prescribed interval of 2 to 3 weeks after the first injection. Group B (N = 96) comprised partial responders who did not receive a repeat injection at the prescribed interval, but received repeat injections only for aggravation of pain. Various clinical data including total number of injections during one year, duration of NRS group A, or after first injection in group B (time to reinjection), were assessed. These data were compared between groups A and B in terms of total population, HIVD, and SS. In the whole population, the mean time to reinjection was 6.09 ± 3.02 months in group A and 3.69 ± 2.07 months in group B. The NRS groups A and B, respectively. In HIVD patients, the mean time to reinjection was 5.82 ± 3.23 months in group A and 3.84 ± 2.34 months in group B, and NRS groups A and B, respectively. In SS patients, the mean time to

  6. Different contrast injection protocols for 64-slice spiral CT coronary angiography

    International Nuclear Information System (INIS)

    Lu Jinguo; Lv Bing; Bai Hua; Tang Xiang; Yang Xinling; Jiang Shiliang; Dai Ruiping; Qiu Jinhai; Chen Tao

    2008-01-01

    Objective: To determine the optimal contrast protocols for 64-slice spiral CT coronary angiography in order to reduce the volume of contrast injection. Methods: One hundred fifty patients scheduled to undergo 64-slice spiral CT coronary angiography were prospectively randomized into the following five groups with different injection protocols: group 1: uniphasic injection without a flush; group 2: biphasic injection with a flush; group 3, group 4 and group 5 : triphasic injection with a diluted contrast material with 3:7, 5:5, 7:3 contrast/saline ratio respectively. Attenuation was measured in the right atrium, right ventricle, left atrium, left ventricle, ascending aorta, right coronary artery and left coronary artery and analyzed with single factor variance test (ANOVA). The quality of the coronary artery images was evaluated and compared using person Chi-Square. Results: The total contrast material volume were (67.0±5.3) ml, (59.9±4.9) ml, (62.9±3.2) ml, (69.2±5.7) ml and (70.9±4.6) ml in five groups respectively (F=27.43, P 2 =18.81, P 2 =31.44, P<0.01). The artifacts in the superior vena cava in group 1 was the most, and in group 2 was the least. The mean enhancement values of right and left coronary arteries in group 2 were significantly greater than those in other groups (F=2.47 and 4.10, P<0.05). The visualization of both left ventricle and right ventricle cavities was the best in group 3. Conclusion: Biphasic injection and triphasic injection are better than uniphasic injection for 64-slice spiral CT coronary angiography and triphasic injection is better than biphasic injection for the visualization of both left ventricle and right ventricle cavities. (authors)

  7. Heart rate effects of intraosseous injections using slow and fast rates of anesthetic solution deposition.

    Science.gov (United States)

    Susi, Louis; Reader, Al; Nusstein, John; Beck, Mike; Weaver, Joel; Drum, Melissa

    2008-01-01

    The authors, using a crossover design, randomly administered, in a single-blind manner, 3 primary intraosseous injections to 61 subjects using: the Wand local anesthetic system at a deposition rate of 45 seconds (fast injection); the Wand local anesthetic system at a deposition rate of 4 minutes and 45 seconds (slow injection); a conventional syringe injection at a deposition rate of 4 minutes and 45 seconds (slow injection), in 3 separate appointments spaced at least 3 weeks apart. A pulse oximeter measured heart rate (pulse). The results demonstrated the mean maximum heart rate was statistically higher with the fast intraosseous injection (average 21 to 28 beats/min increase) than either of the 2 slow intraosseous injections (average 10 to 12 beats/min increase). There was no statistically significant difference between the 2 slow injections. We concluded that an intraosseous injection of 1.4 mL of 2% lidocaine with 1 : 100,000 epinephrine with the Wand at a 45-second rate of anesthetic deposition resulted in a significantly higher heart rate when compared with a 4-minute and 45-second anesthetic solution deposition using either the Wand or traditional syringe.

  8. Detection of active alveolar bone destruction in human periodontal disease by analysis of radiopharmaceutical uptake after a single injection of 99m-Tc-methylene diphosphonate

    International Nuclear Information System (INIS)

    Jeffcoat, M.K.; Williams, R.C.; Holman, B.L.; English, R.; Goldhaber, P.

    1986-01-01

    Previous studies have shown that, following a single injection of 99m-Tc-MDP, measurement of bone-seeking radiopharmaceutical uptake can detect ''active'' alveolar bone loss due to periodontal disease in beagle dogs, as determined by radiographs taken at the time of, and several months after, the nuclear medicine procedure. The efficacy of this diagnostic test, however, had not been assessed in human periodontal disease. The ability of a single boneseeking radiopharmaceutical uptake examination to detect ''active'' alveolar bone loss due to periodontal disease in human patients was assessed by comparing a single uptake measurement to the rate of bone loss determined from serial radiographs taken over a 6-month period. Uptake was expressed as a ratio of the cpm from the alveolar bone divided by the cpm from the non-tooth supporting bone of the nuchal crest. High uptake ratios were associated with ''active'' loss and low uptake ratios were associated with little if any change in alveolar bone height (p<0.001). The nuclear medicine examination was an accurate detector of periodontal disease activity in nearly 80% of the individual teeth studied. These data indicate that high bone-seeking radiopharmaceutical uptake ratios may be pathognomonic of active bone loss in human periodontal disease. (author)

  9. Experimental investigation of gasoline fumigation in a single cylinder direct injection (DI) diesel engine

    International Nuclear Information System (INIS)

    Sahin, Z.; Durgun, O.; Bayram, C.

    2008-01-01

    In the presented study, the effects of gasoline fumigation have been investigated experimentally in a single cylinder direct injection (DI) diesel engine. Gasoline has been introduced into the inlet air flow using an elementary carburetor and no other modification on the engine has been done. The effects of 2%, 4%, 6%, 8% and 10% (by vol.) gasoline fumigation have been investigated experimentally at the speeds of (900-1600) (rpm) and at the selected compression ratios of (18-23). From the experimental results it is determined that by application of gasoline fumigation effective power output increases at the levels of 4-9%, effective efficiency increases by approximately 1.5-4% and specific fuel consumption decreases by approximately 1.5-4%. It is also determined that 4-6% fumigation ratio range is the most favorable percentage interval of gasoline at the selected compression ratios for this engine. Because cost of gasoline is higher than diesel fuel in Turkey as well as in many of the other countries and the decrease ratio of specific fuel consumption is low, gasoline fumigation is not economic for this engine. In the presented study, heat balance tests have also been performed for 18 and 21 compression ratios. The heat balance has been investigated experimentally in respect of effective power, heat rejected to the cooling water, heat lost through exhaust, and other losses (unaccounted-for losses). Heat lost through exhaust decreases until 4-6% gasoline fumigation ratios and after these fumigation ratios it starts to increase because of increasing exhaust gas temperature. Heat rejected to the cooling water decreases at low fumigation ratios, but at high fumigation ratios it increases. Other losses generally exhibit an increasing tendency at low fumigation ratios

  10. Disposal of liquid wastes by injection underground--Neither myth nor millennium

    Science.gov (United States)

    Piper, Arthur M.

    1969-01-01

    Texas-have statutes specifically to regulate injection of industrial wastes. Other States impose widely diverse constraints under unlike administrative authorities. Few, if any, State agencies currently have the staff skills, centralized authority, and financial resources to assure rights of the general public to be spared harm from, and to reap the benefit of accrued experience with, deep injection. Some new, fully competent institutional arrangement appears to be essential, under a unified policy. As required, such an institution might have en echelon components, respectively having nationwide, single State or major province, subprovince, or local jurisdiction.

  11. Numerical studies of spray breakup in a gasoline direct injection (GDI engine

    Directory of Open Access Journals (Sweden)

    Jafarmadar Samad

    2011-01-01

    Full Text Available The objective of this study is to investigate Spray Breakup process of sprays injected from single and two-hole nozzles for gasoline direct Injection (GDI engines by using three dimensional CFD code. Spray characteristics were examined for spray tip penetration and other characteristics including: the vapor phase concentration distribution and droplet spatial distribution, which were acquired using the computational fluid dynamics (CFD simulation. Results showed that as the hole-axis-angle (γ of the two-hole nozzle decreased, the droplet coalescence increased and vapor mass decreased. The spray with cone angle (θ0 5 deg for single hole nozzle has the longest spray tip penetration and the spray with the γ of 30 deg and spray cone angle θ0=30 deg for two hole nozzles had the shortest one. Also, when the spray cone angle (θ0 and hole-axis-angle (γ increased from 5 to 30 deg, the Sauter mean diameter (SMD decreased for both single-hole and two-hole nozzles used in this study. For a single-hole nozzle, when spray cone angle increased from 5 to 30 deg, the vaporization rate very much because of low level of coalescence. The result of model for tip penetration is good agreement with the corresponding experimental data in the literatures.

  12. Colistimethate Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria.Antibiotics such as colistimethate injection will not work for colds, flu, or other viral infections. Using ...

  13. Injection Laryngoplasty Materials

    OpenAIRE

    Haldun Oðuz

    2013-01-01

    Injection laryngoplasty is one of the treatment options for voice problems. In the recent years, more safe and more biocompatible injection materials are available on the market. Long and short term injection materials are discussed in this review.

  14. Glenohumeral Joint Injections

    Science.gov (United States)

    Gross, Christopher; Dhawan, Aman; Harwood, Daniel; Gochanour, Eric; Romeo, Anthony

    2013-01-01

    Context: Intra-articular injections into the glenohumeral joint are commonly performed by musculoskeletal providers, including orthopaedic surgeons, family medicine physicians, rheumatologists, and physician assistants. Despite their frequent use, there is little guidance for injectable treatments to the glenohumeral joint for conditions such as osteoarthritis, adhesive capsulitis, and rheumatoid arthritis. Evidence Acquisition: We performed a comprehensive review of the available literature on glenohumeral injections to help clarify the current evidence-based practice and identify deficits in our understanding. We searched MEDLINE (1948 to December 2011 [week 1]) and EMBASE (1980 to 2011 [week 49]) using various permutations of intra-articular injections AND (corticosteroid OR hyaluronic acid) and (adhesive capsulitis OR arthritis). Results: We identified 1 and 7 studies that investigated intra-articular corticosteroid injections for the treatment of osteoarthritis and adhesive capsulitis, respectively. Two and 3 studies investigated the use of hyaluronic acid in osteoarthritis and adhesive capsulitis, respectively. One study compared corticosteroids and hyaluronic acid injections in the treatment of osteoarthritis, and another discussed adhesive capsulitis. Conclusion: Based on existing studies and their level of evidence, there is only expert opinion to guide corticosteroid injection for osteoarthritis as well as hyaluronic acid injection for osteoarthritis and adhesive capsulitis. PMID:24427384

  15. Injection Tests

    CERN Document Server

    Kain, V

    2009-01-01

    The success of the start-up of the LHC on 10th of September was in part due to the preparation without beam and injection tests in 2008. The injection tests allowed debugging and improvement in appropriate portions to allow safe, efficient and state-of-the-art commissioning later on. The usefulness of such an approach for a successful start-up becomes obvious when looking at the problems we encountered before and during the injection tests and could solve during this period. The outline of the preparation and highlights of the different injection tests will be presented and the excellent performance of many tools discussed. A list of shortcomings will follow, leading to some planning for the preparation of the run in 2009.

  16. Effect of steam injection on nox emissions and performance of a single cylinder diesel engine fuelled with soy methyl ester

    Directory of Open Access Journals (Sweden)

    Manickam Madhavan V.

    2017-01-01

    Full Text Available Biodiesel attracts most of the researchers and automotive industries in recent years as an alternative fuel for diesel engines, because of its better lubricity property, higher cetane number, and less greenhouse gas emissions. The use of bio diesel leads to reduction in hydro carbons, carbon monoxide, and particulate matter, but increase in NOx emissions. Increase in biodiesel blends in standard diesel leads to increase in NOx emission. In this study, an attempt is made to reduce the NOx emis-sions of a diesel engine fueled with pure soy methyl ester (B100 with low pressure steam injection. Experiments were carried out and studied for both standard diesel and pure biodiesel of soy methyl ester with steam injection ratio of 5, 10, and 15% on mass ratio basis of air in the inlet manifold. The present study has shown that around 30% reduction in NOx can be achieved for the steam injection rate of 10% and considerable reduction for all other steam injection rates when compared to standard diesel and B100. It is also observed that steam injection having signifi-cant impact on reduction of other emissions such as HC, CO, and CO2. The study also noted marginal improvement in the engine brake power, brake thermal effi-ciency and reduction in specific fuel consumption at part loads and minor increase during peak load operation for the low pressure steam injection on B100.

  17. Comprehensive low-dose imaging of carotid and coronary arteries with a single-injection dual-source CT angiography protocol

    International Nuclear Information System (INIS)

    Tognolini, A.; Arellano, C.S.; Marfori, W.; Heidari, G.; Sayre, J.W.; Krishnam, M.S.; Ruehm, S.G.

    2014-01-01

    Aim: To assess the feasibility of a fast single-bolus combined carotid and coronary computed tomography angiography (CTA) protocol in asymptomatic patients. Materials and methods: Thirty-three consecutive patients (18 women and 15 men) with a median age of 61 ± 14 years old (range 37–87 years) with known or suspected atherosclerotic disease were enrolled in this prospective study. A single breath-hold, single biphasic injection protocol (50 ml at 3 ml/s, 50 ml at 5 ml/s, 50 ml saline flush at 5 ml/s) was used for combined CTA imaging of the supra-aortic (SAA) and coronary arteries (CA) on a 64-slice dual-source CT (DSCT) machine. Helical CTA acquisition of the SAA was followed by prospective electrocardiography (ECG)-triggered coronary CTA. Subjective (four-point scale) image quality and objective signal-to-noise (SNR) and contrast-to-noise (CNR) measurements were performed. Vascular disease was graded on a four-point scale (grade 1: absent; grade 2: mild, grade 3: moderate; grade 4: severe). The radiation dose was recorded for each patient. Results: The average enhancement and subjective quality score of SAA and CA segments were 396 HU/358 HU and 1.2 ± 0.3/1.72 ± 0.4, respectively. The SNR was 27.1 ± 1.7 in the SAA and 21.6 ± 1.6 in the CA (p < 0.0001). The CNR was 18.1 ± 1.2 and 15.9 ± 1.8, respectively (p = 0.4). Four percent of SAA and 14% of CA segments (mostly due to peri-venous streak artefacts and small calibre, respectively) produced non-diagnostic images. SAA findings were as follows: 26/33 (79%) patients showed no disease and 6/33 (18%) had grade 2 and 1/33 (3%) had grade 3 disease. CA findings were as follows: 25/33 (76%) showed no disease and 6/33 (18%) patients had grade 2 and 2/33 (6%) had grade 3 disease. Five patients had disease in both districts. The average radiation dose for the combined CTA angiogram was 4.3 ± 0.6 mSv. Conclusion: A fast, low-dose combined DSCT angiography protocol appears technically feasible for imaging carotid and

  18. Meropenem Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by killing bacteria that cause infection.Antibiotics such as meropenem injection will not work for colds, flu, or other viral infections. Taking ...

  19. Chloramphenicol Injection

    Science.gov (United States)

    ... injection is in a class of medications called antibiotics. It works by stopping the growth of bacteria..Antibiotics such as chloramphenicol injection will not work for colds, flu, or other viral infections. Taking ...

  20. Performance of CO2 enrich CNG in direct injection engine

    Science.gov (United States)

    Firmansyah, W. B.; Ayandotun, E. Z.; Zainal, A.; Aziz, A. R. A.; Heika, M. R.

    2015-12-01

    This paper investigates the potential of utilizing the undeveloped natural gas fields in Malaysia with high carbon dioxide (CO2) content ranging from 28% to 87%. For this experiment, various CO2 proportions by volume were added to pure natural gas as a way of simulating raw natural gas compositions in these fields. The experimental tests were carried out using a 4-stroke single cylinder spark ignition (SI) direct injection (DI) compressed natural gas (CNG) engine. The tests were carried out at 180° and 300° before top dead centre (BTDC) injection timing at 3000 rpm, to establish the effects on the engine performance. The results show that CO2 is suppressing the combustion of CNG while on the other hand CNG combustion is causing CO2 dissociation shown by decreasing CO2 emission with the increase in CO2 content. Results for 180° BTDC injection timing shows higher performance compared to 300° BTDC because of two possible reasons, higher volumetric efficiency and higher stratification level. The results also showed the possibility of increasing the CO2 content by injection strategy.

  1. Injection molded chips with integrated conducting polymer electrodes for electroporation of cells

    DEFF Research Database (Denmark)

    Andresen, Kristian; Hansen, Morten; Matschuk, Maria

    2010-01-01

    We present the design-concept for an all polymer injection molded single use microfluidic device. The fabricated devices comprise integrated conducting polymer electrodes and Luer fitting ports to allow for liquid and electrical access. A case study of low voltage electroporation of biological...

  2. Effects of single injection of local anesthetic agents on intervertebral disc degeneration: ex vivo and long-term in vivo experimental study.

    Directory of Open Access Journals (Sweden)

    Koji Iwasaki

    Full Text Available Analgesic discography (discoblock can be used to diagnose or treat discogenic low back pain by injecting a small amount of local anesthetics. However, recent in vitro studies have revealed cytotoxic effects of local anesthetics on intervertebral disc (IVD cells. Here we aimed to investigate the deteriorative effects of lidocaine and bupivacaine on rabbit IVDs using an organotypic culture model and an in vivo long-term follow-up model.For the organotypic culture model, rabbit IVDs were harvested and cultured for 3 or 7 days after intradiscal injection of local anesthetics (1% lidocaine or 0.5% bupivacaine. Nucleus pulposus (NP cell death was measured using confocal microscopy. Histological and TUNEL assays were performed. For in vivo study, each local anesthetic was injected into rabbit lumbar IVDs under a fluoroscope. Six or 12 months after the injection, each IVD was prepared for magnetic resonance imaging (MRI and histological analysis.In the organotypic culture model, both anesthetic agents induced time-dependent NP cell death; when compared with injected saline solution, significant effects were detected within 7 days. Compared with the saline group, TUNEL-positive NP cells were significantly increased in the bupivacaine group. In the in vivo study, MRI analysis did not show any significant difference. Histological analysis revealed that IVD degeneration occurred to a significantly level in the saline- and local anesthetics-injected groups compared with the untreated control or puncture-only groups. However, there was no significant difference between the saline and anesthetic agents groups.In the in vivo model using healthy IVDs, there was no strong evidence to suggest that discoblock with local anesthetics has the potential of inducing IVD degeneration other than the initial mechanical damage of the pressurized injection. Further studies should be performed to investigate the deteriorative effects of the local injection of analgesic agents

  3. Worldwide Injection Technique Questionnaire Study: Population Parameters and Injection Practices.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries took part in one of the largest surveys ever performed in diabetes. The goal was to assess patient characteristics, as well as historical and practical aspects of their injection technique. Results show that 4- and 8-mm needle lengths are each used by nearly 30% of patients and 5- and 6-mm needles each by approximately 20%. Higher consumption of insulin (as measured by total daily dose) is associated with having lipohypertrophy (LH), injecting into LH, leakage from the injection site, and failing to reconstitute cloudy insulin. Glycated hemoglobin values are, on average, 0.5% higher in patients with LH and are significantly higher with incorrect rotation of sites and with needle reuse. Glycated hemoglobin values are lower in patients who distribute their injections over larger injection areas and whose sites are inspected routinely. The frequencies of unexpected hypoglycemia and glucose variability are significantly higher in those with LH, those injecting into LH, those who incorrectly rotate sites, and those who reuse needles. Needles associated with diabetes treatment are the most commonly used medical sharps in the world. However, correct disposal of sharps after use is critically suboptimal. Many used sharps end up in public trash and constitute a major accidental needlestick risk. Use of these data should stimulate renewed interest in and commitment to optimizing injection practices in patients with diabetes. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  4. Granisetron Injection

    Science.gov (United States)

    Granisetron immediate-release injection is used to prevent nausea and vomiting caused by cancer chemotherapy and to ... nausea and vomiting that may occur after surgery. Granisetron extended-release (long-acting) injection is used with ...

  5. Edaravone Injection

    Science.gov (United States)

    Edaravone injection is used to treat amyotrophic lateral sclerosis (ALS, Lou Gehrig's disease; a condition in which ... die, causing the muscles to shrink and weaken). Edaravone injection is in a class of medications called ...

  6. Defibrotide Injection

    Science.gov (United States)

    Defibrotide injection is used to treat adults and children with hepatic veno-occlusive disease (VOD; blocked blood ... the body and then returned to the body). Defibrotide injection is in a class of medications called ...

  7. Nalbuphine Injection

    Science.gov (United States)

    ... injection is in a class of medications called opioid agonist-antagonists. It works by changing the way ... suddenly stop using nalbuphine injection, you may experience withdrawal symptoms including restlessness; teary eyes; runny nose; yawning; ...

  8. Short-term outcome after intravitreal ranibizumab injections for the treatment of retinopathy of prematurity.

    Science.gov (United States)

    Castellanos, María Ana Martínez; Schwartz, Shulamit; García-Aguirre, Gerardo; Quiroz-Mercado, Hugo

    2013-07-01

    To evaluate ocular outcome in premature infants treated with intravitreal ranibizumab injections for retinopathy of prematurity (ROP) over a period of 3 years. An interventional case series. Premature infants with high-risk prethreshold or threshold ROP with plus disease received an off label monotherapy with intravitreal injections of ranibizumab. The primary outcome was treatment success defined as regression of neovascularisation (NV) and absence of recurrence. The secondary outcomes were ocular and systemic adverse events and visual acuity. Six eyes were included in the study and treated with intravitreal injections of ranibizumab. All showed complete resolution of NV after a single injection. The anti-angiogenic intravitreal injections allowed for continued normal vessel growth into the peripheral retina, without any signs of disease recurrence or progression during the follow up period. No ocular or systemic adverse effects were observed. Three years of follow up in a small series suggest that intravitreal ranibizumab injections for ROP result in apparently preserved ocular outcome. Further large scale studies are needed to address the long-term safety and efficacy.

  9. Treatment-completion rates with olanzapine long-acting injection versus risperidone long-acting injection in a 12-month, open-label treatment of schizophrenia: indirect, exploratory comparisons

    Directory of Open Access Journals (Sweden)

    Ascher-Svanum H

    2012-05-01

    Full Text Available Haya Ascher-Svanum1, William S Montgomery2, David P McDonnell3, Kristina A Coleman4, Peter D Feldman11Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN, USA; 2Eli Lilly Australia Pty Ltd, West Ryde, New South Wales, Australia; 3Eli Lilly and Company, Cork, Ireland; 4OptumInsight, Lilyfield, New South Wales, AustraliaBackground: Little is known about the comparative effectiveness of atypical antipsychotics in long-acting injection formulation. Due to the absence of head-to-head studies comparing olanzapine long-acting injection and risperidone long-acting injection, this study was intended to make exploratory, indirect, cross-study comparisons between the long-acting formulations of these two atypical antipsychotics in their effectiveness in treating patients with schizophrenia.Methods: Indirect, cross-study comparisons between olanzapine long-acting injection and risperidone long-acting injection used 12-month treatment-completion rates, because discontinuation of an antipsychotic for any cause is a recognized proxy measure of the medication's effectiveness in treating schizophrenia. Following a systematic review of the literature, two indirect comparisons were conducted using open-label, single-cohort studies in which subjects were stabilized on an antipsychotic medication before depot initiation. The first analysis compared olanzapine long-acting injection (one study with pooled data from nine identified risperidone long-acting injection studies. The second analysis was a “sensitivity analysis,” using only the most similar studies, one for olanzapine long-acting injection and one for risperidone long-acting injection, which shared near-identical study designs and involved study cohorts with near-identical patient characteristics. Pearson Chi-square tests assessed group differences on treatment-completion rates.Results: Comparison of olanzapine long-acting injection data (931 patients with the pooled data from the nine

  10. Piezoelectric Injection Systems

    Science.gov (United States)

    Mock, R.; Lubitz, K.

    The origin of direct injection can be doubtlessly attributed to Rudolf Diesel who used air assisted injection for fuel atomisation in his first self-ignition engine. Although it became apparent already at that time that direct injection leads to reduced specific fuel consumption compared to other methods of fuel injection, it was not used in passenger cars for the moment because of its disadvantageous noise generation as the requirements with regard to comfort were seen as more important than a reduced specific consumption.

  11. MD2190: Q" Stabilization during injection

    CERN Document Server

    Schenk, Michael; Li, Kevin Shing Bruce; Malina, Lukas; Metral, Elias; Tomas Garcia, Rogelio; CERN. Geneva. ATS Department

    2018-01-01

    This MD is a follow-up study of MD1831, where single bunches were stabilized against impedance-driven instabilities at 6.5 TeV in the LHC with Q''. The goals are (i) to explore whether an amplitude detuning free Q'' knob can be implemented at injection energy, and (ii) whether Q'' can provide beam stability at injection, where the beams suffer mostly from electron cloud effects. Ideally, this would relax the use of the Landau octupoles and may help in preserving the beam quality by reducing dynamic aperture limitations originating from the octupoles. The MD has been split into two parts: First, optics corrections were put in place to minimize beta-beating and linear coupling introduced by the knobs. The corrections were achieved by means of orbit bumps and skew quadrupole knobs. Machine safety was then validated with loss maps. While the betatron loss maps were approved, the off-momentum maps showed a priori unexpected losses in several arcs and the MD was stopped at this point for reasons of machine protecti...

  12. Numerical Study on the Performance Characteristics of Hydrogen Fueled Port Injection Internal Combustion Engine

    OpenAIRE

    Rosli A. Bakar; Mohammed K. Mohammed; M. M. Rahman

    2009-01-01

    This study was focused on the engine performance of single cylinder hydrogen fueled port injection internal combustion engine. GT-Power was utilized to develop the model for port injection engine. One dimensional gas dynamics was represented the flow and heat transfer in the components of the engine model. The governing equations were introduced first, followed by the performance parameters and model description. Air-fuel ratio was varied from stoichiometric limit to a lean limit and the rota...

  13. Repeated intratracheal instillation of PM10 induces lipid reshaping in lung parenchyma and in extra-pulmonary tissues.

    Directory of Open Access Journals (Sweden)

    Angela Maria Rizzo

    Full Text Available Adverse health effects of air pollution attributed mainly to airborne particulate matter have been well documented in the last couple of decades. Short term exposure, referring to a few hours exposure, to high ambient PM10 concentration is linked to increased hospitalization rates for cardiovascular events, typically 24 h after air pollution peaks. Particulate matter exposure is related to pulmonary and cardiovascular diseases, with increased oxidative stress and inflammatory status. Previously, we have demonstrated that repeated intratracheal instillation of PM10sum in BALB/c mice leads to respiratory tract inflammation, creating in lung a condition which could potentially evolve in a systemic toxic reaction. Additionally, plasma membrane and tissue lipids are easily affected by oxidative stress and directly correlated with inflammatory products. With this aim, in the present investigation using the same model, we analyzed the toxic potential of PM10sum exposure on lipid plasma membrane composition, lipid peroxidation and the mechanisms of cells protection in multiple organs such as lung, heart, liver and brain. Obtained results indicated that PM10 exposure led to lung lipid reshaping, in particular phospholipid and cholesterol content increases; concomitantly, the generation of oxidative stress caused lipid peroxidation. In liver we found significant changes in lipid content, mainly due to an increase of phosphatidylcholine, and in total fatty acid composition with a more pronounced level of docosahexaenoic acid; these changes were statistically correlated to lung molecular markers. Heart and brain were similarly affected; heart was significantly enriched in triglycerides in half of the PM10sum treated mice. These results demonstrated a direct involvement of PM10sum in affecting lipid metabolism and oxidative stress in peripheral tissues that might be related to the serious systemic air-pollution effects on human health.

  14. Beam interaction of a pulsed, nonlinear in-vacuum injection magnet

    International Nuclear Information System (INIS)

    Rast, Helge

    2013-01-01

    Theme of this thesis is the study of the interaction of the injection magnet designed for BESSY II with the electron beam. The main topic of this thesis lies in the numerical and measurement-technical study of the loss factor, the wake potential, and the wake impedance of the nonlinear kicker magnet with the aim of an optimization of the magnet design, so that a stable operation of the kicker in the BESSY II storage ring is made possible. A further main topic of this thesis is a study on the matching of the injection scheme with a single kicker to the conditions of the DELTA storage ring, which is operated by the TU Dortmund.

  15. Antitumor activity of intratracheal inhalation of temozolomide (TMZ) loaded into gold nanoparticles and/or liposomes against urethane-induced lung cancer in BALB/c mice.

    Science.gov (United States)

    Hamzawy, Mohamed A; Abo-Youssef, Amira M; Salem, Heba F; Mohammed, Sameh A

    2017-11-01

    The current study aimed to develop gold nanoparticles (GNPs) and liposome-embedded gold nanoparticles (LGNPs) as drug carriers for temozolomide (TMZ) and investigate the possible therapeutic effects of intratracheal inhalation of nanoformulation of TMZ-loaded gold nanoparticles (TGNPs) and liposome-embedded TGNPs (LTGNPs) against urethane-induced lung cancer in BALB/c mice. Physicochemical characters and zeta potential studies for gold nanoparticles (GNPs) and liposome-embedded gold nanoparticles (LGNPs) were performed. The current study was conducted by inducing lung cancer chemically via repeated exposure to urethane in BALB/C mice. GNPs and LGNPs were exhibited in uniform spherical shape with adequate dispersion stability. GNPs and LGNPs showed no significant changes in comparison to control group with high safety profile, while TGNPs and LTGNPs succeed to improve all biochemical data and histological patterns. GNPs and LGNPs are promising drug carriers and succeeded in the delivery of small and efficient dose of temozolomide in treatment lung cancer. Antitumor activity was pronounced in animal-treated LTGNPs, these effects may be due to synergistic effects resulted from combination of temozolomide and gold nanoparticles and liposomes that may improve the drug distribution and penetration.

  16. Injection characteristics of dimethyl ether

    Energy Technology Data Exchange (ETDEWEB)

    Glensvig, M.

    1996-09-01

    Dimethyl ether (DME) has proved to be a new ultra-clean alternative fuel for diesel engines. Engine tests have shown considerably lower NO{sub x} emissions, no particle emissions and lower noise compared to that obtained from normal diesel engine operation. DME also has demonstrated favorable response to Exhaust Gas Recirculation (EGR). The purpose of this investigation was to achieve a better understanding of the fundamental spray behavior of DME. Fundamental spray behaviour was characterized by fuel spray penetration and angle, atomization and droplet size and evaporation. The influence of fuel characteristics, nozzle geometry and ambient pressure on the DME and diesel spray behavior was investigated. Fuel was injected into an unheated injection chamber with a ambient pressure of 15 bar and 25 bar, respectively, giving a simplified simulation of the environment in an operating engine. Two nozzles were studied: a single hole nozzle and a pintle nozzle. A conventional fuel injection system was used for both nozzles. Injection parameters of RPM, throttle position, fuel line length and chamber environment were held constant for both nozzles. The sprays were visualized using schlieren and high speed photography. Results show that the general appearance of the DME spray is similar to that of diesel spray. The core of the DME spray seems less dense and the spray tip less sharp compared to diesel spray, indicating smaller droplets with a lower momentum in the core of the DME spray. Schlieren film shows that with both DME and diesel fuel, the spray tip only consists of liquid and that evaporation occurs after a brief time interval. Penetration of DME is about one third that of diesel using the pintle nozzle. Also, the spray angle is considerably larger for the DME spray compared to the diesel spray. A comparatively smaller difference in penetration is observed using the hole nozzle. Differences in penetration for the hole nozzle are within the limit of the penetration

  17. Effect of diesel pre-injection timing on combustion and emission characteristics of compression ignited natural gas engine

    International Nuclear Information System (INIS)

    Xu, Min; Cheng, Wei; Zhang, Hongfei; An, Tao; Zhang, Shaohua

    2016-01-01

    Highlights: • Pre-injection timing on combustion and emission of CING engine are studied. • Closely pre-injection operations leads to increase of combustion intensity. • Early pre-injection operations leads to lower combustion intensity. • Early pre-injection modes provide better NO x emission. - Abstract: Pre-injection strategy is considered to be one of the most important ways to improve diesel engine performance, emission and combustion. It is the same important factor in pilot diesel compression ignition natural gas (CING) engine. In this study, effects of pre-injection timing on combustion and emission performances were experimentally studied in a CING engine which was modified from a turbocharged six-cylinder diesel engine. The experiments were conducted at constant speed of 1400 rpm and different engine loads with a constant fuel injection pressure of 1100 bar. Main injection timing was fixed at 10 °CA BTDC in the advance process of pre-injection timing. The cylinder pressure, heart release rate (HRR), pressure rise rate (PRR), start of combustion (SOC) and coefficient of variation (COV IMEP ), as well as NO x , HC and CO emissions were analyzed. The results indicated that closely pre-injection operations lead to the advance of SOC which intensified combustion of in-cylinder mixture, thereby resulting in higher cylinder pressure, HRR and PRR, as well higher NO x emissions and lower HC and CO emissions. However, early pre-injection operations lead to lower cylinder pressure, HRR and PRR due to decreasing in combustion intensity. Pre-injection timing of 70 °CA BTDC is a conversion point in which influence of pre-injection fuel on ignition and combustion of natural gas nearly disappeared and lowest NO x emission could be obtained. Compared with single injection ignition mode, NO x emissions at the conversion point were reduced by 33%, 38% and 7% at engine load of 38%, 60% and 80% respectively. This is important for the conditions that ignition fuel

  18. Dose-Dependent Effects of Multiple Acute Cocaine Injections on Maternal Behavior and Aggression in Sprague-Dawley Rats

    OpenAIRE

    Johns, Josephine M.; Nelson, Christina J.; Meter, Kathleen E.; Lubin, Deborah A.; Couch, C. Destine; Ayers, Andy; Walker, Cheryl H.

    1998-01-01

    Rat dams, which had no prior drug treatment, were either nontreated controls or were injected subcutaneously 4 times during a 10-day period with a single dose of 30, 15 or 7.5 mg/kg of cocaine hydrochloride HCl, or normal saline. Injections were given immediately postpartum following delivery of their final pup (PPD 1), and again on postpartum day 3 (PPD 3), postpartum day 6 (PPD 6) and postpartum day 10 (PPD 10). Dams were observed 30 min following injections for maternal behavior (MB) towar...

  19. Discretely tunable micromachined injection-locked lasers

    International Nuclear Information System (INIS)

    Cai, H; Yu, M B; Lo, G Q; Kwong, D L; Zhang, X M; Liu, A Q; Liu, B

    2010-01-01

    This paper reports a micromachined injection-locked laser (ILL) to provide tunable discrete wavelengths. It utilizes a non-continuously tunable laser as the master to lock a Fabry–Pérot semiconductor laser chip. Both lasers are integrated into a deep-etched silicon chip with dimensions of 3 mm × 3 mm × 0.8 mm. Based on the experimental results, significant improvements in the optical power and spectral purity have been achieved in the fully locked state, and optical hysteresis and bistability have also been observed in response to the changes of the output wavelength and optical power of the master laser. As a whole system, the micromachined ILL is able to provide single mode, discrete wavelength tuning, high power and direct modulation with small size and single-chip solution, making it promising for advanced optical communications such as wavelength division multiplexing optical access networks.

  20. A comparison of molding procedures - Contact, injection and vacuum injection

    Science.gov (United States)

    Cathiard, G.

    1980-06-01

    The technical and economic aspects of the contact, injection and vacuum injection molding of reinforced plastic components are compared for the example of a tractor roof with a gel-coated surface. Consideration is given to the possibility of reinforcement, number of smooth faces, condition of the gel-coated surface, reliability, and labor and workplace requirements of the three processes, and advantages of molding between the mold and a countermold in smooth faces, reliability, labor requirements, working surface and industrial hygiene are pointed out. The times and labor requirements of each step in the molding cycles are examined, and material requirements and yields, investment costs, amortization and product cost prices of the processes are compared. It is concluded that, for the specific component examined, the processes of vacuum injection and injection molding appear very interesting, with injection molding processes resulting in lower cost prices than contact molding for any production volume.

  1. MWCNTs of different physicochemical properties cause similar inflammatory responses, but differences in transcriptional and histological markers of fibrosis in mouse lungs

    DEFF Research Database (Denmark)

    Poulsen, Sarah S.; Saber, Anne T.; Williams, Andrew

    2015-01-01

    Multi-walled carbon nanotubes (MWCNTs) are an inhomogeneous group of nanomaterials that vary in lengths, shapes and types of metal contamination, which makes hazard evaluation difficult. Here we present a toxicogenomic analysis of female C57BL/6 mouse lungs following a single intratracheal instil...

  2. Prevalence of injections and knowledge of safe injections among rural residents in Central China.

    Science.gov (United States)

    Yan, Y W; Yan, J; Zhang, G P; Gao, Z L; Jian, H X

    2007-08-01

    Abuse of the injection services, namely unnecessary injections and unsafe injections, exists extensively in developing countries. Unsafe injection practices contribute to the transmission of blood-borne pathogens. The aims of this study were to survey the prevalence of injections and knowledge of injection safety among the rural residents in Jingzhou district, Hubei, China and to provide scientific data for developing a health educational programme. A retrospective cross-sectional study was conducted in 12 villages, which were selected from the Jingzhou district by the random sampling method. 50 rural residents were interviewed per village using a questionnaire. Among the 595 residents studied, 192 had received at least one injection in the past three months, with an injection prevalence of 32.3 percent and an average of 0.93 injections. 90.3 percent of the rural residents knew that unsafe injections could transmit the following blood-borne pathogens: human immunodeficiency virus (74.4 percent), hepatitis B virus (55.8 percent) and hepatitis C virus (22.9 percent). Logistic regression analysis showed that the residents' age, educational level and residential area were important factors in influencing their knowledge about injection safety. The results indicated that the injection prevalence was high among rural residents in the study area, and their knowledge regarding injection safety should be further improved.

  3. Injection-controlled laser resonator

    Science.gov (United States)

    Chang, J.J.

    1995-07-18

    A new injection-controlled laser resonator incorporates self-filtering and self-imaging characteristics with an efficient injection scheme. A low-divergence laser signal is injected into the resonator, which enables the injection signal to be converted to the desired resonator modes before the main laser pulse starts. This injection technique and resonator design enable the laser cavity to improve the quality of the injection signal through self-filtering before the main laser pulse starts. The self-imaging property of the present resonator reduces the cavity induced diffraction effects and, in turn, improves the laser beam quality. 5 figs.

  4. Reductions in HIV/STI Incidence and Sharing of Injection Equipment among Female Sex Workers Who Inject Drugs: Results from a Randomized Controlled Trial

    Science.gov (United States)

    Strathdee, Steffanie A.; Abramovitz, Daniela; Lozada, Remedios; Martinez, Gustavo; Rangel, Maria Gudelia; Vera, Alicia; Staines, Hugo; Magis-Rodriguez, Carlos; Patterson, Thomas L.

    2013-01-01

    Background We evaluated brief combination interventions to simultaneously reduce sexual and injection risks among female sex workers who inject drugs (FSW-IDUs) in Tijuana and Ciudad Juarez, Mexico during 2008–2010, when harm reduction coverage was expanding rapidly in Tijuana, but less so in Juarez. Methods FSW-IDUs ≥18 years reporting sharing injection equipment and unprotected sex with clients within the last month participated in a randomized factorial trial comparing four brief, single-session conditions combining either an interactive or didactic version of a sexual risk intervention to promote safer sex in the context of drug use, and an injection risk intervention to reduce sharing of needles/injection paraphernalia. Women underwent quarterly interviews and testing for HIV, syphilis, gonorrhea, Chlamydia and Trichomonas, blinding interviewers and assessors to assignment. Poisson regression with robust variance estimation and repeated measures ordinal logistic regression examined effects on combined HIV/STI incidence and receptive needle sharing frequency. Findings Of 584 initially HIV-negative FSW-IDUs, retention was ≥90%. After 12 months, HIV/STI incidence decreased >50% in the interactive vs. didactic sex intervention (Tijuana:AdjRR:0.38,95% CI:0.16–0.89; Juarez: AdjRR:0.44,95% CI:0.19–0.99). In Juarez, women receiving interactive vs. didactic injection risk interventions decreased receptive needle-sharing by 85% vs. 71%, respectively (p = 0.04); in Tijuana, receptive needle sharing declined by 95%, but was similar in active versus didactic groups. Tijuana women reported significant increases in access to syringes and condoms, but Juarez women did not. Interpretation After 12 months in both cities, the interactive sexual risk intervention significantly reduced HIV/STI incidence. Expanding free access to sterile syringes coupled with brief, didactic education on safer injection was necessary and sufficient for achieving robust, sustained

  5. Electrical Initialization of Electron and Nuclear Spins in a Single Quantum Dot at Zero Magnetic Field.

    Science.gov (United States)

    Cadiz, Fabian; Djeffal, Abdelhak; Lagarde, Delphine; Balocchi, Andrea; Tao, Bingshan; Xu, Bo; Liang, Shiheng; Stoffel, Mathieu; Devaux, Xavier; Jaffres, Henri; George, Jean-Marie; Hehn, Michel; Mangin, Stephane; Carrere, Helene; Marie, Xavier; Amand, Thierry; Han, Xiufeng; Wang, Zhanguo; Urbaszek, Bernhard; Lu, Yuan; Renucci, Pierre

    2018-04-11

    The emission of circularly polarized light from a single quantum dot relies on the injection of carriers with well-defined spin polarization. Here we demonstrate single dot electroluminescence (EL) with a circular polarization degree up to 35% at zero applied magnetic field. The injection of spin-polarized electrons is achieved by combining ultrathin CoFeB electrodes on top of a spin-LED device with p-type InGaAs quantum dots in the active region. We measure an Overhauser shift of several microelectronvolts at zero magnetic field for the positively charged exciton (trion X + ) EL emission, which changes sign as we reverse the injected electron spin orientation. This is a signature of dynamic polarization of the nuclear spins in the quantum dot induced by the hyperfine interaction with the electrically injected electron spin. This study paves the way for electrical control of nuclear spin polarization in a single quantum dot without any external magnetic field.

  6. CT-guided cervical nerve root injections: comparing the immediate post-injection anesthetic-related effects of the transforaminal injection with a new indirect technique

    International Nuclear Information System (INIS)

    Sutter, Reto; Pfirrmann, Christian W.A.; Peterson, Cynthia K.; Zanetti, Marco; Hodler, Juerg

    2011-01-01

    To describe an ''indirect'' cervical nerve root injection technique with a dorsal approach that should carry less inherent risk than the ''direct'' cervical transforaminal injection approach, and to compare the immediate post-injection results of the two procedures. The indirect and direct cervical nerve root injection procedures are described in detail. Fifty-three consecutive patients receiving the indirect nerve root injections during 2009-2010 were age- and gender-matched to 53 patients who underwent direct transforaminal nerve root injections performed in 2006. Pain level data were collected immediately before and 20-30 min after each procedure. The percentages of pain change in the two groups were compared using the unpaired Student's t test. Fifty-two men (mean age 49) and 54 women (mean age 55) were included. The mean percentage of pain reduction for patients receiving indirect nerve root injections was 38.4% and for those undergoing the direct nerve root injections approach it was 43.2%. This was not significantly different (P = 0.455). No immediate or late adverse effects were reported after either injection procedure. The indirect cervical nerve root injection procedure is a potentially safer alternative to direct cervical transforaminal nerve root injections. The short-term pain reduction is similar using the two injection methods. (orig.)

  7. Optimization of injection law for direct injection diesel engine

    International Nuclear Information System (INIS)

    Feola, M.; Bella, G.; Pelloni, P.; Casoli, P.; Toderi, G.; Cantore, G.

    1992-01-01

    This paper describes how different timing and shape of the injection law can influence pollutant emission of a direct injection diesel engine. The study was carried out making use of a multizone thermodynamic model as regards the closed valve phase, and a filling-emptying one as regards the open valve phase. After being calibrated by comparison with experimental data, the abovementioned model was used for injection law optimization as regards minimum pollutant concentration (NO x and soot) in the exhaust gases with the smallest engine performance reduction possible

  8. Detection of active alveolar bone destruction in human periodontal disease by analysis of radiopharmaceutical uptake after a single injection of 99m-Tc-methylene diphosphonate

    Energy Technology Data Exchange (ETDEWEB)

    Jeffcoat, M.K.; Williams, R.C.; Holman, B.L.; English, R.; Goldhaber, P.

    1986-01-01

    Previous studies have shown that, following a single injection of 99m-Tc-MDP, measurement of bone-seeking radiopharmaceutical uptake can detect ''active'' alveolar bone loss due to periodontal disease in beagle dogs, as determined by radiographs taken at the time of, and several months after, the nuclear medicine procedure. The efficacy of this diagnostic test, however, had not been assessed in human periodontal disease. The ability of a single boneseeking radiopharmaceutical uptake examination to detect ''active'' alveolar bone loss due to periodontal disease in human patients was assessed by comparing a single uptake measurement to the rate of bone loss determined from serial radiographs taken over a 6-month period. Uptake was expressed as a ratio of the cpm from the alveolar bone divided by the cpm from the non-tooth supporting bone of the nuchal crest. High uptake ratios were associated with ''active'' loss and low uptake ratios were associated with little if any change in alveolar bone height (p<0.001). The nuclear medicine examination was an accurate detector of periodontal disease activity in nearly 80% of the individual teeth studied. These data indicate that high bone-seeking radiopharmaceutical uptake ratios may be pathognomonic of active bone loss in human periodontal disease.

  9. Prediction and Validation of Heat Release Direct Injection Diesel Engine Using Multi-Zone Model

    Science.gov (United States)

    Anang Nugroho, Bagus; Sugiarto, Bambang; Prawoto; Shalahuddin, Lukman

    2014-04-01

    The objective of this study is to develop simulation model which capable to predict heat release of diesel combustion accurately in efficient computation time. A multi-zone packet model has been applied to solve the combustion phenomena inside diesel cylinder. The model formulations are presented first and then the numerical results are validated on a single cylinder direct injection diesel engine at various engine speed and timing injections. The model were found to be promising to fulfill the objective above.

  10. Reliability Analysis of Single-Phase PV Inverters with Reactive Power Injection at Night Considering Mission Profiles

    DEFF Research Database (Denmark)

    Anurag, Anup; Yang, Yongheng; Blaabjerg, Frede

    2015-01-01

    loading, considering the operation outside active feed-in hours. An analytical lifetime model is then employed for lifetime quantization based on the Palgrem Miner rule. Thereafter, considering the lifetime reduction of the PV inverter under different mission profiles with reactive power injection......The widespread adoption of mixed renewables urgently require reactive power exchange at various feed-in points of the utility grid. Photovoltaic (PV) inverters are able to provide reactive power in a decentralized manner at the grid-connection points even outside active power feed-in operation......, especially at night when there is no solar irradiance. This serves as a motivation for utilizing the PV inverters at night for reactive power compensation. Thus, an analysis on the impact of reactive power injection by PV inverters outside feed-in operation on the thermal performance and the reliability has...

  11. Influence of helium-injection schedule and prior thermomechanical treatment on the microstructure of Type 316 SS

    International Nuclear Information System (INIS)

    Kohyama, A.; Ayrault, G.; Turner, A.P.L.

    1982-10-01

    The influence of different helium-injection schedules on microstructure development Ni + ion irradiated 316 SS at 625 0 C is discussed. Injection schedules were chosen to (1) approximate the magnetic fusion reactor condition and (2) mimic the mixed-spectrum reactor condition. Dual-ion irradiation to 25 dpa produced strongly bimodal cavity size distributions in solution-annealed and solution-annealed and aged samples, whereas single-ion irradiation followed by dual-ion irradiation to the same dose produced a cavity size distribution with a substantial component of intermediate-size cavities. Dual-ion irradiation produced only very small cavities in 20% CW material, while single-ion followed by dual-ion irradiation produced some intermediate size cavities and greater swelling. 10 figures

  12. Ultrasound Guidance Versus Peripheral Neurostimulation for Brachial Plexus Block Anesthesia with Axillary Approach and Multiple Injection Technique

    Directory of Open Access Journals (Sweden)

    Lazar Alexandra

    2017-09-01

    Full Text Available Introduction: There are several approaches for brachial plexus anesthesia: supraclavicular, infraclavicular, interscalenic and axillary. Out of these, the axillary approach is considered to be the safest because of the low risk of lesioning the adjacent structures, low risk of phrenic nerve blockade or of producing an iatrogenic pneumothorax. The block can be performed by one single injection at the site, by two injections or by several injection, among each nerve of the plexus. Ultrasound was introduced in regional anesthesia since 1978, being used initially as an auxiliary method to peripheral neurostimulator.

  13. Subcutaneous Injections

    DEFF Research Database (Denmark)

    Thomsen, Maria

    This thesis is about visualization and characterization of the tissue-device interaction during subcutaneous injection. The tissue pressure build-up during subcutaneous injections was measured in humans. The insulin pen FlexTouchr (Novo Nordisk A/S) was used for the measurements and the pressure ...

  14. Hydromorphone Injection

    Science.gov (United States)

    ... anyone else to use your medication. Store hydromorphone injection in a safe place so that no one else can use it accidentally or on purpose. Keep track of how much medication is left so ... with hydromorphone injection may increase the risk that you will develop ...

  15. Ketorolac Injection

    Science.gov (United States)

    ... an older adult, you should know that ketorolac injection is not as safe as other medications that can be used to treat your condition. Your doctor may choose to prescribe a different medication ... to ketorolac injection.Your doctor or pharmacist will give you the ...

  16. Injection septum magnets for the Loma Linda medical accelerator

    International Nuclear Information System (INIS)

    Satti, J.A.

    1987-01-01

    The injection beamline runs over the last magnet before a long straight section and is then displaced downward 55.88 cm to the accelerator beamline. The displacement is magnetic and the final deflection onto the synchrotron orbit is by an electric kicker. The first component, the reverse septum magnet, bends the injection beam 25/degree/ downward. This is followed by the injection septum (20/degree/ bend upward) and the final injection kicker (5/degree/ bend upward). The septum magnets produce a peak field of 3.4 K gauss at a current of 28,000 amperes within a 0.1 msec long pulse. The electric kicker produces a field of 7.3 KV/cm with a pulse length of 0.0011 msec. The septum magnets are similar to each other in construction with a bending radium of 72.7 cm. The curvature is required to increase the effective aperture. Each magnet has a single-turn copper coil bonded to a stainless steel plate for reinforcement. This eliminates insulating material, which could be subject to radiation damage, at the septum. The stainless steel plate is welded to the magnet laminations. The current is confined to the septum by the insulation between the laminations, which are a standard core material. The total septum thickness with shield is 1.227 cm. Pulsing the magnet eliminates the need for water cooling. 2 refs., 4 figs

  17. Electrokinetic gated injection-based microfluidic system for quantitative analysis of hydrogen peroxide in individual HepG2 cells.

    Science.gov (United States)

    Zhang, Xinyuan; Li, Qingling; Chen, Zhenzhen; Li, Hongmin; Xu, Kehua; Zhang, Lisheng; Tang, Bo

    2011-03-21

    A microfluidic system to determine hydrogen peroxide (H(2)O(2)) in individual HepG2 cells based on the electrokinetic gated injection was developed for the first time. A home-synthesized fluorescent probe, bis(p-methylbenzenesulfonate)dichlorofluorescein (FS), was employed to label intracellular H(2)O(2) in the intact cells. On a simple cross microchip, multiple single-cell operations, including single cell injection, cytolysis, electrophoresis separation and detection of H(2)O(2), were automatically carried out within 60 s using the electrokinetic gated injection and laser-induced fluorescence detection (LIFD). The performance of the method was evaluated under the optimal conditions. The linear calibration curve was over a range of 4.39-610 amol (R(2)=0.9994). The detection limit was 0.55 amol or 9.0×10(-10) M (S/N=3). The relative standard deviations (RSDs, n=6) of migration time and peak area were 1.4% and 4.8%, respectively. With the use of this method, the average content of H(2)O(2) in single HepG2 cells was found to be 16.09±9.84 amol (n=15). Separation efficiencies in excess of 17,000 theoretical plates for the cells were achieved. These results demonstrated that the efficient integration and automation of these single-cell operations enabled the sensitive, reproducible, and quantitative examination of intracellular H(2)O(2) at single-cell level. Owing to the advantages of simple microchip structure, controllable single-cell manipulation and ease in building, this platform provides a universal way to automatically determine other intracellular constituents within single cells. This journal is © The Royal Society of Chemistry 2011

  18. Geothermal Injection Monitoring Project. Phase I status report, April 1981-April 1982

    Energy Technology Data Exchange (ETDEWEB)

    Younker, L.; Hanson, J.; Didwall, E.; Kasameyer, P.; Smith, A.; Hearst, J.; Daily, W.; Crow, N.; Younker, J.; Murray, W.

    1982-08-13

    The feasibility of using remote geophysical techniques to monitor the movement of injected brine has been evaluated. It was established that no single approach is likely to be identified that can be used to accurately monitor the precise location of the injected fluid. Several approaches have been considered in parallel because they add new dimensions to the existing monitoring capabilities, and are likely to cover a range of applications at a variety of geothermal sites. These include: microseismicity - a seismic net is used to record small magnitude events associated with injection; streaming potential - self potential anomalies produced by a moving fluid identify fluid flow direction; cross borehole geotomography - two-dimensional image of flow pathways is constructed using electromagnetic waves; and well pressure response to solid earth tide - changes in pore pressures are used to discriminate fracture/pore porosity and estimate fracture orientations.

  19. Saline as the Sole Contrast Agent for Successful MRI-guided Epidural Injections

    International Nuclear Information System (INIS)

    Deli, Martin; Fritz, Jan; Mateiescu, Serban; Busch, Martin; Carrino, John A.; Becker, Jan; Garmer, Marietta; Grönemeyer, Dietrich

    2013-01-01

    Purpose. To assess the performance of sterile saline solution as the sole contrast agent for percutaneous magnetic resonance imaging (MRI)-guided epidural injections at 1.5 T. Methods. A retrospective analysis of two different techniques of MRI-guided epidural injections was performed with either gadolinium-enhanced saline solution or sterile saline solution for documentation of the epidural location of the needle tip. T1-weighted spoiled gradient echo (FLASH) images or T2-weighted single-shot turbo spin echo (HASTE) images visualized the test injectants. Methods were compared by technical success rate, image quality, table time, and rate of complications. Results. 105 MRI-guided epidural injections (12 of 105 with gadolinium-enhanced saline solution and 93 of 105 with sterile saline solution) were performed successfully and without complications. Visualization of sterile saline solution and gadolinium-enhanced saline solution was sufficient, good, or excellent in all 105 interventions. For either test injectant, quantitative image analysis demonstrated comparable high contrast-to-noise ratios of test injectants to adjacent body substances with reliable statistical significance levels (p < 0.001). The mean table time was 22 ± 9 min in the gadolinium-enhanced saline solution group and 22 ± 8 min in the saline solution group (p = 0.75). Conclusion. Sterile saline is suitable as the sole contrast agent for successful and safe percutaneous MRI-guided epidural drug delivery at 1.5 T.

  20. Influence of injection timing on the exhaust emissions of a dual-fuel CI engine

    Energy Technology Data Exchange (ETDEWEB)

    Sayin, Cenk [Department of Mechanical Education, Marmara University, 34722 Istanbul (Turkey); Uslu, Kadir [Department of Automotive Education, Fatih Vocational High School, 54100 Sakarya (Turkey); Canakci, Mustafa [Department of Mechanical Education, Kocaeli University, 41380 Kocaeli (Turkey); Alternative Fuels R and D Center, Kocaeli University, 41040 Kocaeli (Turkey)

    2008-06-15

    Environmental concerns and limited amount of petroleum fuels have caused interests in the development of alternative fuels for internal combustion (IC) engines. As an alternative, biodegradable, and renewable fuel, ethanol is receiving increasing attention. Therefore, in this study, influence of injection timing on the exhaust emission of a single cylinder, four stroke, direct injection, naturally aspirated diesel engine has been experimentally investigated using ethanol blended diesel fuel from 0% to 15% with an increment of 5%. The engine has an original injection timing 27 CA BTDC. The tests were performed at five different injection timings (21 , 24 , 27 , 30 , and 33 CA BTDC) by changing the thickness of advance shim. The experimental test results showed that NO{sub x} and CO{sub 2} emissions increased as CO and HC emissions decreased with increasing amount of ethanol in the fuel mixture. When compared to the results of original injection timing, at the retarded injection timings (21 and 24 CA BTDC), NO{sub x} and CO{sub 2} emissions increased, and unburned HC and CO emissions decreased for all test conditions. On the other hand, with the advanced injection timings (30 and 33 CA BTDC), HC and CO emissions diminished, and NO{sub x} and CO{sub 2} emissions boosted for all test conditions. (author)

  1. Highly ordered uniform single-crystal Bi nanowires: fabrication and characterization

    International Nuclear Information System (INIS)

    Bisrat, Y; Luo, Z P; Davis, D; Lagoudas, D

    2007-01-01

    A mechanical pressure injection technique has been used to fabricate uniform bismuth (Bi) nanowires in the pores of an anodic aluminum oxide (AAO) template. The AAO template was prepared from general purity aluminum by a two-step anodization followed by heat treatment to achieve highly ordered nanochannels. The nanowires were then fabricated by an injection technique whereby the molten Bi was injected into the AAO template using a hydraulic pressure method. The Bi nanowires prepared by this method were found to be dense and continuous with uniform diameter throughout the length. Electron diffraction experiments using the transmission electron microscope on cross-sectional and free-standing longitudinal Bi nanowires showed that the majority of the individual nanowires were single crystalline, with preferred orientation of growth along the [011] zone axis of the pseudo-cubic structure. The work presented here provides an inexpensive and effective way of fabricating highly ordered single-crystalline Bi nanowires, with uniform size distributions

  2. Intravitreal injection of ziv-aflibercept in the treatment of choroidal and retinal vascular diseases.

    Science.gov (United States)

    HodjatJalali, Kamran; Mehravaran, Shiva; Faghihi, Hooshang; Hashemi, Hassan; Kazemi, Pegah; Rastad, Hadith

    2017-09-01

    To investigate the short-term outcomes after intravitreal injection of ziv-aflibercept in the treatment of choroidal and retinal vascular diseases. Thirty-four eyes of 29 patients with age-related macular degeneration (AMD), diabetic retinopathy, and retinal vein occlusion (RVO) received a single dose intravitreal injection of 0.05 ml ziv-aflibercept (1.25 mg). Visual acuity, spectral domain optical coherence tomography (SD-OCT) activity, and possible side effects were assessed before and at 1 week and 1 month after the intervention. At 1 month after treatment, mean central macular thickness (CMT) significantly decreased from 531.09 μm to 339.5 μm ( P  < 0.001), and no signs of side effects were observed in any subject. All patients responded to treatment in terms of reduction in CMT. The improvement in visual acuity was statistically non-significant. Our findings suggest that a single dose intravitreal injection of ziv-aflibercept may have acceptable relative safety and efficacy in the treatment of patients with intraocular vascular disease. The trial was registered in the Iranian Registry of Clinical Trials (IRCT2015081723651N1).

  3. Paclitaxel Injection

    Science.gov (United States)

    (pak'' li tax' el)Paclitaxel injection must be given in a hospital or medical facility under the supervision of a doctor who is experienced in giving chemotherapy medications for cancer.Paclitaxel injection may cause a large decrease in the number of white blood cells (a type of blood cell ...

  4. Ultrasound-guided versus fluoroscopy-guided sacroiliac joint intra-articular injections in the noninflammatory sacroiliac joint dysfunction: a prospective, randomized, single-blinded study.

    Science.gov (United States)

    Jee, Haemi; Lee, Ji-Hae; Park, Ki Deok; Ahn, Jaeki; Park, Yongbum

    2014-02-01

    To compare the short-term effects and safety of ultrasound (US)-guided sacroiliac joint (SIJ) injections with fluoroscopy (FL)-guided SIJ injections in patients with noninflammatory SIJ dysfunction. Prospective, randomized controlled trial. University hospital. Patients (N=120) with noninflammatory sacroiliac arthritis were enrolled. All procedures were performed using an FL or US apparatus. Subjects were randomly assigned to either the FL or US group. Immediately after the SIJ injections, fluoroscopy was applied to verify the correct placement of the injected medication and intravascular injections. Treatment effects and functional improvement were compared at 2 and 12 weeks after the procedures. The verbal numeric pain scale and Oswestry Disability Index improved at 2 and 12 weeks after the injections without statistical significances between groups. Of 55 US-guided injections, 48 (87.3%) were successful and 7 (12.7%) were missed. The FL-guided SIJ approach exhibited a greater accuracy (98.2%) than the US-guided approach. Vascularization around the SIJ was seen in 34 of 55 patients. Among the 34 patients, 7 had vascularization inside the joint, 23 had vascularization around the joint, and 4 had vascularization both inside and around the joint. Three cases of intravascular injections occurred in the FL group. The US-guided approach may facilitate the identification and avoidance of the critical vessels around or within the SIJ. Function and pain relief significantly improved in both groups without significant differences between groups. The US-guided approach was shown to be as effective as the FL-guided approach in treatment effects. However, diagnostic application in the SIJ may be limited because of the significantly lower accuracy rate (87.3%). Copyright © 2014 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  5. Effects of single intratracheal exposure to chlorhexidine gluconate on the rat lung.

    Science.gov (United States)

    Orito, Kensuke; Hashida, Masaru; Hirata, Kiyotaka; Kurokawa, Akira; Shirai, Mitsuyuki; Akahori, Fumiaki

    2006-01-01

    Chlorhexidine gluconate (CHX) is an antiseptic that has been widely used for disinfection of cutaneous wound and gingivae. Recently, a patient who inhaled CHX solution died from acute respiratory distress syndrome (ARDS). Although it is highly possible that direct pulmonary damage might be the cause of ARDS, there is no preclinical information about the pulmonary toxicity of CHX. In the current study, the acute direct action of CHX to the lung was evaluated in rats. We successfully exposed the left but not the right lung either to CHX at concentrations of 1%, 0.1%, and 0.01% or to saline using a curved-tip administration tube. At the higher concentrations of CHX (0.1% and 1%), severe congestion to the alveoli and capillaries and perivascular and intra-alveolar hemorrhages were observed 1 day after exposure. Aniline blue-stained collagen fibers with an infiltration of inflammatory cells were present 7 days after exposure. The fibrotic changes and intra-alveolar inflammatory cells had decreased but were still observed sporadically 28 and 84 days after exposure. These detrimental effects were more severe at 1% than at 0.1% CHX. No remarkable effect was observed after exposures to 0.01% CHX and saline. We were able to evaluate the time-course changes in the pulmonary toxicity of CHX by exposures limited to the left lung. It is highly possible that CHX at a concentration of more than 0.1% might directly induce ARDS when aspirated and reaching to the alveoli.

  6. Steroid injection for shoulder pain causes prolonged increased glucose level in type 1 diabetics

    OpenAIRE

    Povlsen, Bo; Povlsen, Sebastian D

    2014-01-01

    Shoulder pain is very common in diabetic patients and often treated with steroid injections, with subsequent increases in blood glucose levels or the need for additional insulin being questioned. We report a case of significant and prolonged elevation of blood glucose levels and resultant insulin requirement in a type 1 diabetic man after a single 40 mg injection of triamcinolone for shoulder pain. Within 48 h, the shoulder pain as assessed by a visual analogue scale (0–10) was reduced to zer...

  7. Single-copy insertion of transgenes in Caenorhabditis elegans

    DEFF Research Database (Denmark)

    Frøkjaer-Jensen, Christian; Davis, M Wayne; Hopkins, Christopher E

    2008-01-01

    developed a method that inserts a single copy of a transgene into a defined site. Mobilization of a Mos1 transposon generates a double-strand break in noncoding DNA. The break is repaired by copying DNA from an extrachromosomal template into the chromosomal site. Homozygous single-copy insertions can...... be obtained in less than 2 weeks by injecting approximately 20 worms. We have successfully inserted transgenes as long as 9 kb and verified that single copies are inserted at the targeted site. Single-copy transgenes are expressed at endogenous levels and can be expressed in the female and male germlines....

  8. Corticosteroid injections, eccentric decline squat training and heavy slow resistance training in patellar tendinopathy

    DEFF Research Database (Denmark)

    Kongsgaard, M.; Kovanen, V.; Aagaard, P.

    2009-01-01

    A randomized-controlled single-blind trial was conducted to investigate the clinical, structural and functional effects of peritendinous corticosteroid injections (CORT), eccentric decline squat training (ECC) and heavy slow resistance training (HSR) in patellar tendinopathy. Thirty-nine male...

  9. Electrically-pumped, broad-area, single-mode photonic crystal lasers.

    Science.gov (United States)

    Zhu, Lin; Chak, Philip; Poon, Joyce K S; DeRose, Guy A; Yariv, Amnon; Scherer, Axel

    2007-05-14

    Planar broad-area single-mode lasers, with modal widths of the order of tens of microns, are technologically important for high-power applications and improved coupling efficiency into optical fibers. They may also find new areas of applications in on-chip integration with devices that are of similar size scales, such as for spectroscopy in microfluidic chambers or optical signal processing with micro-electromechanical systems. An outstanding challenge is that broad-area lasers often require external means of control, such as injection-locking or a frequency/spatial filter to obtain single-mode operation. In this paper, we propose and demonstrate effective index-guided, large-area, edge-emitting photonic crystal lasers driven by pulsed electrical current injection at the optical telecommunication wavelength of 1550 nm. By suitable design of the photonic crystal lattice, our lasers operate in a single mode with a 1/e(2) modal width of 25 microm and a length of 600 microm.

  10. Comparison of clinical applications of single-dose intravenous injection of mivacurium and cisatracurium in adults’ vocalcordpolyps resection under self-retaining laryngoscope

    Directory of Open Access Journals (Sweden)

    Han Fanglei

    2017-01-01

    Full Text Available Objective: Through comparing the clinical observation of mivacurium and cisatracurium in vocal polyp extraction, to study the advantage of mivacurium in vocal polyp extraction. Methods: Forty American Society of Anesthesiologists(ASA physical status I~II patients for vocal polyp extraction, aged 18~60 years old, were randomly divided into two groups as Mivacurium injection group(Group M and Cis-atracurium injection group(Group C, each group includes 20 subjects. None of the patients are allergic, has serious diseases of cardiovascular system, liver or kidney.None of them has asthma, airway high response, difficult airway or neuromuscular diseases.Those patients who use beta-blockers or calcium channel blockers for a long time were excluded .All the subjects had the same premedication, fasting and fluid fobidden time. All the subjects who get into the operating room get the routine monitoring of electrocardiogram(EEG, blood pressure(BP, heart rate(HR, pulse oxygen saturation(SpO2 and the TOF WATCH SX. Each group gives the same medicine other than the muscle relaxant during induction of general anesthesia to do the vocal polyp extraction by the same experienced operator. Two groups were recorded in each index of anesthesia induction and tracheal intubation conditions, operation conditions, anesthesia, muscle relaxation monitoring. Results: There are no statistically significant in Cormack-Lehane grading system,Cooper’s grading system and operation satifaction(p>0.05. 2. Group A have shorter intubation time than Group B(p0.05. Conclusion: 1. A single intubating dose of mivacurium can provide similar intubation and surgeon satisfaction for the vocal polyp extraction. 2. Compared with cis-atracurium, mivacurium can shorten the intubation time and the recovery time of anesthesia. The adverse reactions of mivacurium is mild, and it has less Residual muscle relaxation. Therefore mivacurium is more suitable for the vocal polyp extraction than cis-atracurium.

  11. Effects of pilot injection pressure on the combustion and emissions characteristics in a diesel engine using biodiesel–CNG dual fuel

    International Nuclear Information System (INIS)

    Ryu, Kyunghyun

    2013-01-01

    Highlights: • Injection pressure of pilot fuel in dual fuel combustion (DFC) affects the engine power and exhaust emissions. • In the biodiesel–CNG DFC mode, the combustion begins and ends earlier as the pilot-fuel injection pressure increases. • The ignition delay in the DFC mode is about 1.2–2.6 °CA longer than that in the diesel single fuel combustion (SFC) mode. • The smoke and NOx emissions are significantly reduced in the DFC mode. - Abstract: Biodiesel–compressed natural gas (CNG) dual fuel combustion (DFC) system is studied for the simultaneous reduction of particulate matters (PM) and nitrogen oxides (NOx) from diesel engine. In this study, biodiesel is used as a pilot injection fuel to ignite the main fuel, CNG of DFC system. In particular, the pilot injection pressure is controlled to investigate the characteristics of engine performance and exhaust emissions in a single cylinder diesel engine. The results show that the indicated mean effective pressure (IMEP) of biodiesel–CNG DFC mode is lower than that of diesel single fuel combustion (SFC) mode at higher injection pressure. However, the combustion stability of biodiesel–CNG DFC mode is increased with the increase of pilot injection pressure. At the same injection pressure, the start of combustion of biodiesel–CNG DFC is delayed compared to diesel SFC due to the increase of ignition delay of pilot fuel. On the contrary, it is observed that as the pilot injection pressure increase, the combustion process begins and ends a little earlier for biodiesel–CNG DFC. The ignition delay in the DFC is about 1.2–2.6 °CA longer compared to diesel SFC, but decreases with increases of pilot injection pressure. Smoke and NOx emissions are decreased and increased, respectively, as the pilot injection pressure increases in the biodiesel–CNG DFC. In comparison to diesel SFC, smoke emissions are significantly reduced over all the operating conditions and NOx emissions also exhibited similar

  12. Injection dynamics of gelled propellants

    Science.gov (United States)

    Yoon, Changjin

    Gel propellants have been recognized as attractive candidates for future propulsion systems due to the reduced tendency to spill and the energy advantages over solid propellants. One of strong benefits emphasized in gel propellant applications is a throttling capability, but the accurate flow control is more complicated and difficult than with conventional Newtonian propellants because of the unique rheological behaviors of gels. This study is a computational effort directed to enhance understanding of the injector internal flow characteristics for gel propellants under rocket injection conditions. In simulations, the emphasized rheology is a shear-thinning which represents a viscosity decrease with increasing a shear rate. It is described by a generalized Newtonian fluid constitutive equation and Carreau-Yasuda model. Using this rheological model, two injection schemes are considered in the present study: axially-fed and cross-fed injection for single-element and multi-element impinging injectors, respectively. An axisymmetric model is developed to describe the axially-fed injector flows and fully three-dimensional model is utilized to simulate cross-fed injector flows. Under axially-fed injection conditions investigated, three distinct modes, an unsteady, steady, and hydraulic flip mode, are observed and mapped in terms of Reynolds number and orifice design. In an unsteady mode, quasi-periodic oscillations occur near the inlet lip leading mass pulsations and viscosity fluctuations at the orifice exit. This dynamic behavior is characterized using a time-averaged discharge coefficient, oscillation magnitude and frequency by a parametric study with respect to an orifice design, Reynolds number and rheology. As a result, orifice exit flows for gel propellants appear to be significantly influenced by a viscous damping and flow resistance due to a shear thinning behavior and these are observed in each factors considered. Under conditions driven by a manifold crossflow

  13. Impact of CO2 injection protocol on fluid-solid reactivity: high-pressure and temperature microfluidic experiments in limestone

    Science.gov (United States)

    Jimenez-Martinez, Joaquin; Porter, Mark; Carey, James; Guthrie, George; Viswanathan, Hari

    2017-04-01

    Geological sequestration of CO2 has been proposed in the last decades as a technology to reduce greenhouse gas emissions to the atmosphere and mitigate the global climate change. However, some questions such as the impact of the protocol of CO2 injection on the fluid-solid reactivity remain open. In our experiments, two different protocols of injection are compared at the same conditions (8.4 MPa and 45 C, and constant flow rate 0.06 ml/min): i) single phase injection, i.e., CO2-saturated brine; and ii) simultaneous injection of CO2-saturated brine and scCO2. For that purpose, we combine a unique high-pressure/temperature microfluidics experimental system, which allows reproducing geological reservoir conditions in geo-material substrates (i.e., limestone, Cisco Formation, Texas, US) and high resolution optical profilometry. Single and multiphase flow through etched fracture networks were optically recorded with a microscope, while processes of dissolution-precipitation in the etched channels were quantified by comparison of the initial and final topology of the limestone micromodels. Changes in hydraulic conductivity were quantified from pressure difference along the micromodel. The simultaneous injection of CO2-saturated brine and scCO2, reduced the brine-limestone contact area and also created a highly heterogeneous velocity field (i.e., low velocities regions or stagnation zones, and high velocity regions or preferential paths), reducing rock dissolution and enhancing calcite precipitation. The results illustrate the contrasting effects of single and multiphase flow on chemical reactivity and suggest that multiphase flow by isolating parts of the flow system can enhance CO2 mineralization.

  14. Safety and efficacy of bi-annual intra-articular LBSA0103 injections in patients with knee osteoarthritis.

    Science.gov (United States)

    Lee, Jin Kyu; Choi, Chong-Hyuk; Oh, Kwang-Jun; Kyung, Hee-Soo; Yoo, Ju-Hyung; Ha, Chul-Won; Bin, Seong-Il; Kang, Seung-Baik; Kim, Myung Ku; Lee, Ju-Hong; Lee, Myung Chul

    2017-11-01

    The objective of this study is to assess the safety and efficacy of repeated intra-articular injection of high molecular weight hyaluronic acid (LBSA0103) at a 26-week interval, in patients with osteoarthritis of the knee. The study was an open-label, single arm, multicentre prospective trial conducted in patients with symptomatic knee osteoarthritis. The intervention consisted of two intra-articular injections of LBSA0103, with the second injection performed 26 weeks after the first injection. The primary outcome was the incidence of adverse drug reactions related to each injection. Assessment of efficacy of repeated injections in terms of maintenance of pain relief was a secondary objective of this study. Of the 185 patients screened, 174 patients received the first injection and 153 patients received both injections of LBSA0103. Nine adverse drug reactions occurred in seven patients (4.02%) after the first injection, while only one adverse drug reaction occurred (0.65%) after the second injection. As a secondary outcome measure, the improvements in the efficacy parameters including total WOMAC score and weight-bearing pain were all significant at both week 13 and 39 compared to the baseline value (P injection were consistent with those after the initial injection of LBSA0103 (between week 26 and week 39, P injection of LBSA0103 at a 26-week interval is safe without increased risk of adverse drug reactions. Additionally, LBSA0103 is effective in reduction of osteoarthritis knee pain and in maintenance of pain reduction for a 39-week period when a second injection is administered.

  15. Multilevel Botulinum Toxin A (Abobotulinum Toxin A Injections in Spastic Forms of Cerebral Palsy: Retrospective Analysis of 8 Russian Centers Experience

    Directory of Open Access Journals (Sweden)

    O. A. Klochkova

    2016-01-01

    Full Text Available Background: The contemporary application of Botulinum toxin A (BTA in cerebral palsy (CP implies multilevel injections both in on-label and off-label muscles. However, there is no single international opinion on the effective and safe dosages, target muscles, and intervals between the injections.Objective: Our aim was to analyze the Russian multicenter independent experience of single and repeated multilevel injections of Abobotulinum toxin А in patients with spastic forms of CP.Methods: 8 independent referral CP-centers (10 hospitals in different regions of Russia. Authors evaluated intervals between the injections, dosages of the BTA for the whole procedure, for the body mass, for the each muscle, and functional segment of the extremities.Results: 1872 protocols of effective BTA injections (1–14 repeated injections for 724 patients with spastic CP were included. The age of the patients was between 8 months to 17 years 4 months at the beginning of the treatment (with a mean of 3 years 10 months. Multilevel BTA injections were indicated for the majority (n = 634, 87.6% of the patients in all the centers. The medians of the dosages for the first BTA injection were between 30–31 U/kg (500 U, the repeated injections doses up to 45 U/kg (1000 U (in most centers. The median intervals between the repeated injections were 180–200 days in 484 (66.9% patients and 140–180 days in 157 (24.7% patients. In 2 centers, children with GMFCS IV–V were injected more often than others.Conclusion: Multilevel BTA injections were indicated for the most patients. The initial dose of Abobotulinum toxin A was 30–31 U/kg. The repeated injections dose could increase up to 40 U/kg. The repeated injections were done in 140–200 days after the previous injection.

  16. 3D Adaptive Mesh Refinement Simulations of Pellet Injection in Tokamaks

    International Nuclear Information System (INIS)

    Samtaney, S.; Jardin, S.C.; Colella, P.; Martin, D.F.

    2003-01-01

    We present results of Adaptive Mesh Refinement (AMR) simulations of the pellet injection process, a proven method of refueling tokamaks. AMR is a computationally efficient way to provide the resolution required to simulate realistic pellet sizes relative to device dimensions. The mathematical model comprises of single-fluid MHD equations with source terms in the continuity equation along with a pellet ablation rate model. The numerical method developed is an explicit unsplit upwinding treatment of the 8-wave formulation, coupled with a MAC projection method to enforce the solenoidal property of the magnetic field. The Chombo framework is used for AMR. The role of the E x B drift in mass redistribution during inside and outside pellet injections is emphasized

  17. Investigation of High Pressure, Multi-Hole Diesel Fuel Injection Using High Speed Imaging

    Science.gov (United States)

    Morris, Steven; Eagle, Ethan; Wooldridge, Margaret

    2012-10-01

    Research to experimentally capture and understand transient fuel spray behavior of modern fuel injection systems remains underdeveloped. To this end, a high-pressure diesel common-rail fuel injector was instrumented in a spherical, constant volume combustion chamber to image the early time history of injection of diesel fuel. The research-geometry fuel injector has four holes aligned on a radial plane of the nozzle with hole sizes of 90, 110, 130 and 150 μm in diameter. Fuel was injected into a non-reacting environment with ambient densities of 17.4, 24.0, and 31.8 kg/m3 at fuel rail pressures of 1000, 1500, and 2000 bar. High speed images of fuel injection were taken using backlighting at 100,000 frames per second (100 kfps) and an image processing algorithm. The experimental results are compared with a one-dimensional fuel-spray model that was historically developed and applied to fuel sprays from single-hole fuel injectors. Fuel spray penetration distance was evaluated as a function of time for the different injector hole diameters, fuel injection pressures and ambient densities. The results show the differences in model predictions and experimental data at early times in the spray development.

  18. Radiation carcinogenesis. Comprehensive final report, 16 May 1979-31 December 1980

    International Nuclear Information System (INIS)

    Warren, S.; Brown, C.E.; Gates, O.

    1981-03-01

    This abstract covers three main areas of investigation: mesothelioma induction by asbestos, radiation tumorigenesis and transplantable tumors. Canadian and Rhodesian asbestos fibers have been administered under anesthesia to rats by intratracheal, intrapleural and intraperitoneal injection. Additional groups were given 3-methylcholanthrene or x-radiation along with asbestos. A large series of mice also treated as above have displayed mesotheliomas. In addition, glass fiber injections and feeding of asbestos were done and have produced negative results to date. The carcinogenic effect of whole-body radiation on hemi-irradiated parabiont partners exposed to a single 1000 R dose of x-ray was evidenced by a significant increase in the incidence of malignant tumors in only six tissues: skin, supporting soft tissue, kidney, bone, pancreatic islets and ovary. In the male adrenal medulla and in the female breast genetic and parabiotic hormonal factors were judged to exert a significant effect. The occurrence of incisional (anastomotic) sarcomas in significant numbers in hemi-irradiated and parabiont control pairs suggests the operation of mechanical factors complicating the healing process, only slightly enhanced by radiation. One of the very valuable but unanticipated developments of the rat radiation program was the isolation of two transplantable endocrine tumors with strong hormonal potentials: an insulinoma of the pancreas and a pheochromocytoma of the adrenal medulla

  19. Power deposition by neutral beam injected fast ions in field-reversed configurations

    International Nuclear Information System (INIS)

    Takahashi, Toshiki; Kato, Takayuki; Kondoh, Yoshiomi; Iwasaka, Naotaka

    2004-04-01

    Effects of Coulomb collisions on neutral beam (NB) injected fast ions into Field-Reversed Configuration (FRC) plasmas are investigated by calculating the single particle orbits, where the ions are subject to the slowing down and pitch angle collisions. The Monte-Carlo method is used for the pitch angle scattering, and the friction term is added to the equation of motion to show effects of slowing down collision such as the deposited power profile. Calculation parameters used are relevant to the NB injection on the FRC Injection Experiment (FIX) device. It is found that the dominant local power deposition occurs in the open field region between the X-point and the mirror point because of a concentration of fast ions and a longer duration travel at the mirror reflection point. In the present calculation, the maximum deposited power to the FRC plasma is about 10% of the injected power. Although the pitch angle scattering by Coulomb collision destroys the mirror confinement of NB injected fast ions, this effect is found negligible. The loss mechanism due to non-adiabatic fast ion motion, which is intrinsic in non-uniform FRC plasmas, affects much greater than the pitch angle scattering by Coulomb collision. (author)

  20. Single-photon generator for optical telecommunication wavelength

    International Nuclear Information System (INIS)

    Usuki, T; Sakuma, Y; Hirose, S; Takemoto, K; Yokoyama, N; Miyazawa, T; Takatsu, M; Arakawa, Y

    2006-01-01

    We report on the generation of single-photon pulses from a single InAs/InP quantum dot in telecommunication bands (1.3-1.55 μm: higher transmittance through an optical fiber). First we prepared InAs quantum dots on InP (0 0 1) substrates in a low-pressure MOCVD by using a so-called InP 'double-cap' procedure. The quantum dots have well-controlled photo emission wavelength in the telecommunication bands. We also developed a single-photon emitter in which quantum dots were embedded. Numerical simulation designed the emitter to realize efficient injection of the emitted photons into a single-mode optical fiber. Using a Hanbury-Brown and Twiss technique has proved that the photons through the fiber were single photons

  1. Experimental Investigation of the Effect of Hydrogen Manifold Injection on the Performance of Compression Ignition Engines

    OpenAIRE

    Haroun A.K. Shahad; Nabeel Abdul-Hadi

    2011-01-01

    Experiments were carried out to evaluate the influence of the addition of hydrogen to the inlet air on the performance of a single cylinder direct injection diesel engine. Hydrogen was injected in the inlet manifold. The addition of hydrogen was done on energy replacement basis. It was found that the addition of hydrogen improves the combustion process due to superior combustion characteristics of hydrogen in comparison to conventional diesel fuels. It was also found that...

  2. Compressed air injection technique to standardize block injection pressures : [La technique d'injection d'air comprimé pour normaliser les pressions d'injection d'un blocage nerveux].

    Science.gov (United States)

    Tsui, Ban C H; Li, Lisa X Y; Pillay, Jennifer J

    2006-11-01

    Presently, no standardized technique exists to monitor injection pressures during peripheral nerve blocks. Our objective was to determine if a compressed air injection technique, using an in vitro model based on Boyle's law and typical regional anesthesia equipment, could consistently maintain injection pressures below a 1293 mmHg level associated with clinically significant nerve injury. Injection pressures for 20 and 30 mL syringes with various needle sizes ( 18G, 20G, 21 G, 22G, and 24G) were measured in a closed system. A set volume of air was aspirated into a saline-filled syringe and then compressed and maintained at various percentages while pressure was measured. The needle was inserted into the injection port of a pressure sensor, which had attached extension tubing with an injection plug clamped "off". Using linear regression with all data points, the pressure value and 99% confidence interval (CI) at 50% air compression was estimated. The linearity of Boyle's law was demonstrated with a high correlation, r = 0.99, and a slope of 0.984 (99% CI: 0.967-1.001). The net pressure generated at 50% compression was estimated as 744.8 mmHg, with the 99% CI between 729.6 and 760.0 mmHg. The various syringe/needle combinations had similar results. By creating and maintaining syringe air compression at 50% or less, injection pressures will be substantially below the 1293 mmHg threshold considered to be an associated risk factor for clinically significant nerve injury. This technique may allow simple, real-time and objective monitoring during local anesthetic injections while inherently reducing injection speed. Présentement, aucune technique normalisée ne permet de vérifier les pressions d'injection pendant les blocages nerveux périphériques. Nous voulions vérifier si une technique d'injection d'air comprimé, utilisant un modèle in vitro fondé sur la loi de Boyle et du matériel propre à l'anesthésie régionale, pouvait maintenir avec régularité les

  3. Stability of optically injected two-state quantum-dot lasers

    Energy Technology Data Exchange (ETDEWEB)

    Meinecke, Stefan; Lingnau, Benjamin; Roehm, Andre; Luedge, Kathy [Institut fuer Theoretische Physik, Technische Universitaet Berlin (Germany)

    2017-12-15

    Simultaneous two-state lasing is a unique property of semiconductor quantum-dot (QD) lasers. This not only changes steady-state characteristics of the laser device but also its dynamic response to perturbations. In this paper we investigate the dynamic stability of QD lasers in an external optical injection setup. Compared to conventional single-state laser devices, we find a strong suppression of dynamical instabilities in two-state lasers. Furthermore, depending on the frequency and intensity of the injected light, pronounced areas of bistability between both lasing frequencies appear, which can be employed for fast optical switching in all-optical photonic computing applications. These results emphasize the suitability of QD semiconductor lasers in future integrated optoelectronic systems where a high level of stability is required. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  4. Stability of optically injected two-state quantum-dot lasers

    International Nuclear Information System (INIS)

    Meinecke, Stefan; Lingnau, Benjamin; Roehm, Andre; Luedge, Kathy

    2017-01-01

    Simultaneous two-state lasing is a unique property of semiconductor quantum-dot (QD) lasers. This not only changes steady-state characteristics of the laser device but also its dynamic response to perturbations. In this paper we investigate the dynamic stability of QD lasers in an external optical injection setup. Compared to conventional single-state laser devices, we find a strong suppression of dynamical instabilities in two-state lasers. Furthermore, depending on the frequency and intensity of the injected light, pronounced areas of bistability between both lasing frequencies appear, which can be employed for fast optical switching in all-optical photonic computing applications. These results emphasize the suitability of QD semiconductor lasers in future integrated optoelectronic systems where a high level of stability is required. (copyright 2017 by WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Comparative study of diode-pumping self-injection and injection-locking Tm:YAG lasers

    International Nuclear Information System (INIS)

    Wu, C T; Chen, F; Ju, Y L; Wang, Y Z

    2013-01-01

    A comparative study of the laser characteristics of self-injection and injection-locking Tm:YAG lasers is given in this paper. At a pump energy of 145 mJ and Q-switched repetition rate of 100 Hz, an output energy of 2.39 mJ was obtained for an injection-locking Tm:YAG laser, with a pulse width of 403.2 ns and a pulse building-up time of 2.12 μs. Under the same conditions, the output energy, pulse width and pulse build-up time for a self-injection Tm:YAG laser were 2.21 mJ, 407.0 ns and 3.95 μs, respectively. The threshold of the Q-switched injection-locking Tm:YAG laser was much lower than that of the self-injection laser, and the pulse width was narrower and the pulse build-up time shorter. Additionally, the output spectrum was much purer for the injection-locking laser. (paper)

  6. Calculation method of water injection forward modeling and inversion process in oilfield water injection network

    Science.gov (United States)

    Liu, Long; Liu, Wei

    2018-04-01

    A forward modeling and inversion algorithm is adopted in order to determine the water injection plan in the oilfield water injection network. The main idea of the algorithm is shown as follows: firstly, the oilfield water injection network is inversely calculated. The pumping station demand flow is calculated. Then, forward modeling calculation is carried out for judging whether all water injection wells meet the requirements of injection allocation or not. If all water injection wells meet the requirements of injection allocation, calculation is stopped, otherwise the demand injection allocation flow rate of certain step size is reduced aiming at water injection wells which do not meet requirements, and next iterative operation is started. It is not necessary to list the algorithm into water injection network system algorithm, which can be realized easily. Iterative method is used, which is suitable for computer programming. Experimental result shows that the algorithm is fast and accurate.

  7. Worldwide Injection Technique Questionnaire Study: Injecting Complications and the Role of the Professional.

    Science.gov (United States)

    Frid, Anders H; Hirsch, Laurence J; Menchior, Astrid R; Morel, Didier R; Strauss, Kenneth W

    2016-09-01

    From February 1, 2014, through June 30, 2015, 13,289 insulin-injecting patients from 423 centers in 42 countries participated in one of the largest surveys ever performed in diabetes. The first results of this survey are published elsewhere in this issue. Herein we report that the most common complication of injecting insulin is lipohypertrophy (LH), which was self-reported by 29.0% of patients and found by physical examination in 30.8% by health care professionals (HCPs). Patients with LH consumed a mean of 10.1 IU more insulin daily than patients without LH. Glycated hemoglobin levels averaged 0.55% higher in patients with vs without LH. Lipohypertrophy was associated with higher rates of unexplained hypoglycemia and glycemic variability as well as more frequent diabetic ketoacidosis, incorrect rotation of injection sites, use of smaller injection zones, longer duration of insulin use, and reuse of pen needles (each P<.05). Routine inspection of injection sites by the HCP was associated with lower glycated hemoglobin levels, less LH, and more correct injection site rotation. Patients were also more likely to rotate correctly if they received injection instructions from their HCP in the past 6 months. Fewer than 40% of patients claimed to have gotten such instructions in the past 6 months, and 10% said that they have never received training on how to inject correctly despite injecting for a mean of nearly 9 years. Use of these data should stimulate renewed commitment to optimizing insulin injection practices. Copyright © 2016 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  8. Approximate and analytical solutions for solute transport from an injection well into a single fracture

    International Nuclear Information System (INIS)

    Chen, C.S.; Yates, S.R.

    1989-01-01

    In dealing with problems related to land-based nuclear waste management, a number of analytical and approximate solutions were developed to quantify radionuclide transport through fractures contained in the porous formation. It has been reported that by treating the radioactive decay constant as the appropriate first-order rate constant, these solutions can also be used to study injection problems of a similar nature subject to first-order chemical or biological reactions. The fracture is idealized by a pair of parallel, smooth plates separated by an aperture of constant thickness. Groundwater was assumed to be immobile in the underlying and overlying porous formations due to their low permeabilities. However, the injected radionuclides were able to move from the fracture into the porous matrix by molecular diffusion (the matrix diffusion) due to possible concentration gradients across the interface between the fracture and the porous matrix. Calculation of the transient solutions is not straightforward, and the paper documents a contained Fortran program, which computes the Stehfest inversion, the Airy functions, and gives the concentration distributions in the fracture as well as in the porous matrix for both transient and steady-state cases

  9. Hydrogen/oxygen injection stopping method for nuclear power plant and emergent hydrogen/oxygen injection device

    International Nuclear Information System (INIS)

    Ishida, Ryoichi; Ota, Masamoto; Takagi, Jun-ichi; Hirose, Yuki

    1998-01-01

    The present invention provides a device for suppressing increase of electroconductivity of reactor water during operation of a BWR type reactor, upon occurrence of reactor scram of the plant or upon stopping of hydrogen/oxygen injection due to emergent stoppage of an injection device so as not to deteriorate the integrity of a gas waste processing system upon occurrence of scram. Namely, when injection of hydrogen/oxygen is stopped during plant operation, the injection amount of hydrogen is reduced gradually. Subsequently, injection of hydrogen is stopped. With such procedures, the increase of electroconductivity of reactor water can be suppressed upon stoppage of hydrogen injection. When injection of hydrogen/oxygen is stopped upon shut down of the plant, the amount of hydrogen injection is changed depending on the change of the feedwater flow rate, and then the plant is shut down while keeping hydrogen concentration of feedwater to a predetermined value. With such procedures, increase of the reactor water electroconductivity can be suppressed upon stoppage of hydrogen injection. Upon emergent stoppage of the hydrogen/oxygen injection device, an emergent hydrogen/oxygen injection device is actuated to continue the injection of hydrogen/oxygen. With such procedures, elevation of reactor water electroconductivity can be suppressed. (I.S.)

  10. H/sup /minus// injection into the low-energy booster of the SSC

    International Nuclear Information System (INIS)

    Colton, E.P.; Thiessen, H.A.

    1988-01-01

    Protons are accumulated into the low-energy booster of the SSC by utilizing H/sup /minus// → H + conversion in a 225- μg/cm 2 carbon stripping foil. Synchronous injection is performed for 26 turns into stationary rf buckets, thereby allowing operation with variable bunch spacing. By injecting the beam offset in x and y we obtain the required rms normalized transverse emittance area of 0.75 π mm-mr. Similarly the required rms longitudinal emittance area of 1.75π /times/ 10/sup /minus/3/ eVs is obtained by injecting single linac micropulses, centered at /phi/ = 0, and dp/p = +0.12%, into each 49.9-MHz rf bucket formed with an rf voltage of 350 kV. The transverse space-charge tune shift is -0.17 for 10 10 protons/bunch accumulated at 600 MeV. 1 ref., 5 figs., 1 tab

  11. Efficacy and safety of cross-linked hyaluronic acid single injection on osteoarthritis of the knee: a post-marketing Phase IV study.

    Science.gov (United States)

    Bashaireh, Khaldoon; Naser, Ziad; Hawadya, Khaled Al; Sorour, Sorour; Al-Khateeb, Rami Nabeel

    2015-01-01

    The primary objective of this study was to evaluate the efficacy, safety, and duration of action of viscosupplementation with Crespine® Gel over a 9-month period. The study was a post-marketing Phase IV study. A total of 109 participants with osteoarthritis of the knee (grades 1-4) in the tibio-femoral compartment were recruited in Jordan. Data were collected from each participant during the baseline visit. Each participant received Crespine® Gel injection, and follow-up visits took place at 3 months, 6 months, and 9 months post-injection. An assessment of participants by phone was conducted at 1 month, 2 months, 4 months, 5 months, 7 months, and 8 months post-injection. Western Ontario and McMaster Universities Arthritis Index questionnaires were completed during each visit. A 72-hour visit questionnaire was used to assess the safety of the injection. Statistical analysis included a two-sided 95% confidence interval for the difference between pain scores across visits, and the percent change from baseline was calculated. The full analysis included 84 participants who gave their informed consent and finished the necessary baseline and follow-up visits needed to assess efficacy and safety. Peak improvement was noted at 5 months post-injection, when pain and physical performance scores had decreased to 2.60 and 9.90, respectively, and the stiffness score was 0.33. The peak improvement in stiffness was noted at 8 months post-injection, when the stiffness score had decreased to 0.32. Significant improvements were still apparent at 9 months post-injection, when the pain score was 3.36, the stiffness score was 0.42, and the physical performance score was 11.5. All side effects were local and transient, and included pain, swelling, and redness of the knee. Most side effects were treated. Hyaluronan should be encouraged as an alternative or adjunct treatment to oral analgesics to reduce their required doses, and delay potential future surgical intervention.

  12. Coupled Viscous Fluid Flow and Joint Deformation Analysis for Grout Injection in a Rock Joint

    Science.gov (United States)

    Kim, Hyung-Mok; Lee, Jong-Won; Yazdani, Mahmoud; Tohidi, Elham; Nejati, Hamid Reza; Park, Eui-Seob

    2018-02-01

    Fluid flow modeling is a major area of interest within the field of rock mechanics. The main objective of this study is to gain insight into the performance of grout injection inside jointed rock masses by numerical modeling of grout flow through a single rock joint. Grout flow has been widely simulated using non-Newtonian Bingham fluid characterized by two main parameters of dynamic viscosity and shear yield strength both of which are time dependent. The increasing value of these properties with injection time will apparently affect the parameters representing the grouting performance including grout penetration length and volumetric injection rate. In addition, through hydromechanical coupling a mutual influence between the injection pressure from the one side and the joint opening/closing behavior and the aperture profile variation on the other side is anticipated. This is capable of producing a considerable impact on grout spread within the rock joints. In this study based on the Bingham fluid model, a series of numerical analysis has been conducted using UDEC to simulate the flow of viscous grout in a single rock joint with smooth parallel surfaces. In these analyses, the time-dependent evolution of the grout fluid properties and the hydromechanical coupling have been considered to investigate their impact on grouting performance. In order to verify the validity of these simulations, the results of analyses including the grout penetration length and the injection flow rate were compared with a well-known analytical solution which is available for the simple case of constant grout properties and non-coupled hydraulic analysis. The comparison demonstrated that the grout penetration length can be overestimated when the time-dependent hardening of grout material is not considered. Moreover, due to the HM coupling, it was shown that the joint opening induced by injection pressure may have a considerable increasing impression on the values of penetration length and

  13. Pulsed injection metal organic chemical vapour deposition and characterisation of thin CaO films

    International Nuclear Information System (INIS)

    Borges, R.P.; Ferreira, P.; Saraiva, A.; Goncalves, R.; Rosa, M.A.; Goncalves, A.P.; Silva, R.C. da; Magalhaes, S.; Lourenco, M.J.V.; Santos, F.J.V.; Godinho, M.

    2009-01-01

    Thin films of CaO were grown on silicon (Si) and lanthanum aluminate (LaAlO 3 ) substrates by pulsed injection metal-organic chemical vapour deposition in a vertical injection MOCVD system. Growth parameters were systematically varied to study their effect on film growth and quality and to determine the optimal growth conditions for this material. Film quality and growth rate were evaluated by atomic force microscopy, X-ray diffraction and Rutherford Backscattering Spectroscopy measurements. Optimised conditions allowed growing transparent, single phase films textured along the (0 0 l) direction.

  14. Penicillin G Procaine Injection

    Science.gov (United States)

    Penicillin G procaine injection is used to treat certain infections caused by bacteria. Penicillin G procaine injection should not be used to ... early in the treatment of certain serious infections. Penicillin G procaine injection is in a class of ...

  15. A facile single injection Hydrothermal method for the synthesis of thiol capped CdTe Quantum dots as light harvesters

    Energy Technology Data Exchange (ETDEWEB)

    Jai Kumar, B.; Sumanth Kumar, D.; Mahesh, H.M., E-mail: hm_mahesh@rediffmail.com

    2016-10-15

    A facile, Single Injection Hydrothermal (SIH) method has been developed to synthesize high quality 3-Mercaptopropionic Acid (MPA) stabilized aqueous CdTe QDs, entirely in ambient environment. The synthesis protocol eliminates the use of inert atmosphere for reducing elemental Tellurium powder to Te precursor avoiding the oxidation of Te powder. The XRD result revealed that the synthesized QDs are in cubic zincblende type crystalline structure, without signature of Te oxidation. FTIR spectra have confirmed the attachment of short chained organic compound MPA to the surface of QDs by covalent bond. The Quantum confinement effect was clearly evident by shift in Longitudinal Optic (LO) peak of Raman spectra and absorption peak wavelength with respect to bulk CdTe materials. The optical direct band gap energy of CdTe QDs is between 3.63 eV to 1.96 eV and QDs size below 6 nm, confirm the QDs are well under strong Quantum confinement regime. Also, photoluminescence spectra depict a stable and high luminescence emission from green to dark red color. All these results corroborate that the synthesis of CdTe QDs procedure is very advantageous and present a simple, economical and easily up scalable method for large scale production.

  16. Efficacy and safety of cross-linked hyaluronic acid single injection on osteoarthritis of the knee: a post-marketing phase IV study

    Directory of Open Access Journals (Sweden)

    Bashaireh K

    2015-04-01

    Full Text Available Khaldoon Bashaireh,1 Ziad Naser,2 Khaled Al Hawadya,2 Sorour Sorour,2 Rami Nabeel Al-Khateeb3 1Department of Orthopedics Surgery, King Abdullah University Hospital, Jordan University of Science and Technology, Irbid, Jordan; 2Private Clinic, 3Elaf Medical Supplies Company, Amman, Jordan Purpose: The primary objective of this study was to evaluate the efficacy, safety, and duration of action of viscosupplementation with Crespine® Gel over a 9-month period.Materials and methods: The study was a post-marketing phase IV study. A total of 109 participants with osteoarthritis of the knee (grades 1–4 in the tibio–femoral compartment were recruited in Jordan. Data were collected from each participant during the baseline visit. Each participant received Crespine® Gel injection, and follow-up visits took place at 3 months, 6 months, and 9 months post-injection.Main outcome measure(s: An assessment of participants by phone was conducted at 1 month, 2 months, 4 months, 5 months, 7 months, and 8 months post-injection. Western Ontario and McMaster Universities Arthritis Index questionnaires were completed during each visit. A 72-hour visit questionnaire was used to assess the safety of the injection. Statistical analysis included a two-sided 95% confidence interval for the difference between pain scores across visits, and the percent change from baseline was calculated.Main results: The full analysis included 84 participants who gave their informed consent and finished the necessary baseline and follow-up visits needed to assess efficacy and safety. Peak improvement was noted at 5 months post-injection, when pain and physical performance scores had decreased to 2.60 and 9.90, respectively, and the stiffness score was 0.33. The peak improvement in stiffness was noted at 8 months post-injection, when the stiffness score had decreased to 0.32. Significant improvements were still apparent at 9 months post-injection, when the pain score was 3

  17. Therapeutic hip injections: Is the injection volume important?

    International Nuclear Information System (INIS)

    Young, R.; Harding, J.; Kingsly, A.; Bradley, M.

    2012-01-01

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  18. Therapeutic hip injections: Is the injection volume important?

    Energy Technology Data Exchange (ETDEWEB)

    Young, R., E-mail: russell.young@gwh.nhs.uk [Department of Radiology, Great Western Hospital, Swindon (United Kingdom); Harding, J. [Department of Radiology, University Hospital Coventry, Coventry (United Kingdom); Kingsly, A. [Department of Mathematics and Statistics, Bristol Institue of Technology, University of the West of England, Bristol (United Kingdom); Bradley, M. [Department of Radiology, Southmead Hospital, Bristol (United Kingdom)

    2012-01-15

    Aim: To assess whether an increased volume of local anaesthetic injection given with intra-articular steroids improves symptom relief in osteoarthritis of the hip. Materials and methods: One hundred and ten patients with hip osteoarthritis were randomized into two groups (A and B). All patients were given 40 mg triamcinolone and 2 ml bupivicaine, and patients from group B were also given 6 ml of sterile water for injection. Change in WOMAC (Western Ontario and McMaster University Osteoarthritis Index Version 3.1) scores from baseline to 3 months were calculated and assessed for clinical and statistical significance. The patients were assessed for pain at 2 weekly intervals using the Oxford pain chart. Results: Patients from group B showed some reduction in stiffness (7%) and improved function (3%) compared with group A, and there were more clinical responders in these two categories. However, there was no significant statistical or clinical difference in WOMAC scores between the two groups at 3 months. There was also no statistical difference in pain symptoms between the two groups during the study period, measured at 2 weekly intervals. One hundred and two patients reached the study endpoint; eight patients who had bilateral hip injections were subsequently included in the analysis, and these patients did not alter the findings significantly. Conclusions: Published total injection volumes used for treating osteoarthritis of the hip with intra-articular steroids vary from 3 to 12 ml. The present study has shown that there is no detriment to using a larger volume of injectate, and recommends that practitioners use total volumes between 3 and 9 ml.

  19. 78 FR 23246 - Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for...

    Science.gov (United States)

    2013-04-18

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9804-8] Underground Injection Control Program; Hazardous Waste Injection Restrictions; Petition for Exemption--Class I Hazardous Waste Injection; BASF... exemption to the land disposal Restrictions, under the 1984 Hazardous and Solid Waste [[Page 23247...

  20. Preliminary study of Conbercept injected intravitreally for the treatment of wet age-related macular degeneration

    Directory of Open Access Journals (Sweden)

    Ying Qin

    2017-08-01

    Full Text Available AIM:To observe the preliminary efficacy of conbercept injected intravitreally for the treatment of wet age-related macular degeneration(wAMD.METHODS:Seventeen wAMD patients(18 eyeswere selected to receive conbercept injection. All patients were given a single conbercept injection every month, 3 times. Before and after 1, 2, 3mo of the injection, the best corrected visual acuity(BCVA, intraocular pressure(IOP, measured by Non-contact tonometer, fundus photography, fundus fluorescein angiography(FFA, indocyanine green angiography(ICG, optical coherence tomography(OCTexamination and the complications incidence were compared.RESULTS:Three months after conbercept injection, the BCVA improved in 15 eyes(83%, stable in 3 eyes(17%. Before treatment, the average central macular thickness was 421.72±54.43μm, at 1 and 2 and 3mo after treatment, the average central macular thickness was 337.89±25.88μm, 293.56±26.87μm, 266.89±19.10μm respectively. There were significant differences compared with before and after injection(PCONCLUSION:Intravitreal injection conbercept for wAMD can significantly improve the visual function, reduce the macular edema and the leakage with higher safety and less complications. However the prolonged efficacy needs further observation.