WorldWideScience

Sample records for simple measurement device

  1. A Simple Device for Measuring Static Compliance of Lung-Thorax Combine

    Science.gov (United States)

    Sircar, Sabyasachi

    2015-01-01

    Explaining the concept of lung compliance remains a challenge to the physiology teacher because it cannot be demonstrated easily in human subjects and all attempts until now have used only simulation models. A simple device is described in the present article to measure the compliance of the "lung-thorax" combine in human subjects with…

  2. A Simple Device For Measuring Skin Friction

    Directory of Open Access Journals (Sweden)

    Gupta A.B

    1995-01-01

    Full Text Available A simple device for measuring skin friction in vivo is described. The frictional coefficient of normal Indian skin and the effect of hydration and application of talc and glycerol on the frictional coefficient and also the friction of ichthyotic skin have been determined with its help. The average value of friction of friction of normal India skin at forearm is found to be 0.41 +- 0.08, the hydration raises the value to 0.71 +- 0.11 and the effect of glycerol is also to school it up to 0.70+- 0.05, almost equal to that of water. The effect of talc however is opposite and its application lowers the friction to 0.21+-0.07. The mean coeff of friction for ichthyotic skin is found to be 0.21+- 0.0.5, which closely agrees with talc-treated normal skin. A good positive correlation (p<0.01 between friction and sebum level at skin site, with r = 0.64, has been observed.

  3. Validity and reliability of simple measurement device to assess the velocity of the barbell during squats.

    Science.gov (United States)

    Lorenzetti, Silvio; Lamparter, Thomas; Lüthy, Fabian

    2017-12-06

    The velocity of a barbell can provide important insights on the performance of athletes during strength training. The aim of this work was to assess the validity and reliably of four simple measurement devices that were compared to 3D motion capture measurements during squatting. Nine participants were assessed when performing 2 × 5 traditional squats with a weight of 70% of the 1 repetition maximum and ballistic squats with a weight of 25 kg. Simultaneously, data was recorded from three linear position transducers (T-FORCE, Tendo Power and GymAware), an accelerometer based system (Myotest) and a 3D motion capture system (Vicon) as the Gold Standard. Correlations between the simple measurement devices and 3D motion capture of the mean and the maximal velocity of the barbell, as well as the time to maximal velocity, were calculated. The correlations during traditional squats were significant and very high (r = 0.932, 0.990, p squats and was less accurate. All the linear position transducers were able to assess squat performance, particularly during traditional squats and especially in terms of mean velocity and time to maximal velocity.

  4. Characterizing Information Processing With a Mobile Device: Measurement of Simple and Choice Reaction Time.

    Science.gov (United States)

    Burke, Daniel; Linder, Susan; Hirsch, Joshua; Dey, Tanujit; Kana, Daniel; Ringenbach, Shannon; Schindler, David; Alberts, Jay

    2017-10-01

    Information processing is typically evaluated using simple reaction time (SRT) and choice reaction time (CRT) paradigms in which a specific response is initiated following a given stimulus. The measurement of reaction time (RT) has evolved from monitoring the timing of mechanical switches to computerized paradigms. The proliferation of mobile devices with touch screens makes them a natural next technological approach to assess information processing. The aims of this study were to determine the validity and reliability of using of a mobile device (Apple iPad or iTouch) to accurately measure RT. Sixty healthy young adults completed SRT and CRT tasks using a traditional test platform and mobile platforms on two occasions. The SRT was similar across test modality: 300, 287, and 280 milliseconds (ms) for the traditional, iPad, and iTouch, respectively. The CRT was similar within mobile devices, though slightly faster on the traditional: 359, 408, and 384 ms for traditional, iPad, and iTouch, respectively. Intraclass correlation coefficients ranged from 0.79 to 0.85 for SRT and from 0.75 to 0.83 for CRT. The similarity and reliability of SRT across platforms and consistency of SRT and CRT across test conditions indicate that mobile devices provide the next generation of assessment platforms for information processing.

  5. Licensing of simple digital devices

    International Nuclear Information System (INIS)

    Jackson, T. W.

    2008-01-01

    The inability to guarantee error-free software gave rise to the potential for common-cause failure of digital safety systems in nuclear power plants. To address this vulnerability, the U. S. Nuclear Regulatory Commission (NRC) required a quality software development process and a defense-in-depth and diversity analysis for digital safety systems. As a result of recent interim [NRC] staff guidance in the digital instrumentation and control (I and C) area, licensing of simple digital devices decreases some regulatory burden with respect to demonstrating a quality software development process and defense-in-depth and diversity analysis. This paper defines simple digital devices and addresses the interim staff guidance that applies to such devices. The paper also highlights the technical aspects that affect the licensing of such devices and incorporates licensing experience in the U.S. to date. (authors)

  6. A Simple Laser-Based Device for Simultaneous Microbial Culture and Absorbance Measurement

    OpenAIRE

    Abrevaya, X. C.; Cortón, E.; Areso, O.; Mauas, P. J. D.

    2012-01-01

    In this work we present a device specifically designed to study microbial growth with several applications related to environmental microbiology and other areas of research as astrobiology. The Automated Measuring and Cultivation device (AMC-d) enables semi-continuous absorbance measurements directly during cultivation. It can measure simultaneously up to 16 samples. Growth curves using low and fast growing microorganism were plotted, including Escherichia coli and Haloferax volcanii, a halop...

  7. A simple laser-based device for simultaneous microbial culture and absorbance measurement

    Science.gov (United States)

    Abrevaya, X. C.; Cortón, E.; Areso, O.; Mauas, P. J. D.

    2013-07-01

    In this work we present a device specifically designed to study microbial growth with several applications related to environmental microbiology and other areas of research as astrobiology. The Automated Measuring and Cultivation device (AMC-d) enables semi-continuous absorbance measurements directly during cultivation. It can measure simultaneously up to 16 samples. Growth curves using low and fast growing microorganism were plotted, including Escherichia coli and Haloferax volcanii, a halophilic archaeon.

  8. A simple indentation device for measuring micrometer-scale tissue stiffness

    Energy Technology Data Exchange (ETDEWEB)

    Levental, I; Levental, K R; Janmey, P A [Institute for Medicine and Engineering, University of Pennsylvania, Philadelphia, PA 19104 (United States); Klein, E A; Assoian, R [Department of Pharmacology, University of Pennsylvania, Philadelphia, PA 19104 (United States); Miller, R T [Departments of Medicine and Physiology, Louis Stokes VAMC, Cleveland, OH (United States); Wells, R G, E-mail: janmey@mail.med.upenn.ed [Department of Medicine, University of Pennsylvania, Philadelphia, PA 19104 (United States)

    2010-05-19

    Mechanical properties of cells and extracellular matrices are critical determinants of function in contexts including oncogenic transformation, neuronal synapse formation, hepatic fibrosis and stem cell differentiation. The size and heterogeneity of biological specimens and the importance of measuring their mechanical properties under conditions that resemble their environments in vivo present a challenge for quantitative measurement. Centimeter-scale tissue samples can be measured by commercial instruments, whereas properties at the subcellular (nm) scale are accessible by atomic force microscopy, optical trapping, or magnetic bead microrheometry; however many tissues are heterogeneous on a length scale between micrometers and millimeters which is not accessible to most current instrumentation. The device described here combines two commercially available technologies, a micronewton resolution force probe and a micromanipulator for probing soft biological samples at sub-millimeter spatial resolution. Several applications of the device are described. These include the first measurement of the stiffness of an intact, isolated mouse glomerulus, quantification of the inner wall stiffness of healthy and diseased mouse aortas, and evaluation of the lateral heterogeneity in the stiffness of mouse mammary glands and rat livers with correlation of this heterogeneity with malignant or fibrotic pathology as evaluated by histology.

  9. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  10. Short report: evaluation of a simple and inexpensive photometric device for the measurement of hemoglobin

    NARCIS (Netherlands)

    Borrmann, Steffen; Oyakhirome, Sunny; Esser, Gilbert; Trinkle, Cordula; Issifou, Saadou; Grobusch, Martin P.; Krishna, Sanjeev; Kremsner, Peter G.

    2004-01-01

    We have evaluated the accuracy of a simple and inexpensive photometric device (DHT) for the estimation of the blood concentration of hemoglobin by comparison with an automated, high-resolution, flow cytometry-based hematology analyzer (CellDyn 3000) and a centrifugal quantitative buffy coat

  11. Simple traction-immobilization device for CT scanners

    International Nuclear Information System (INIS)

    Robertson, J.; Federle, M.P.

    1983-01-01

    Successful computed tomographic (CT) scanning of acutely ill or traumatized patients often requires immobilization or traction of the extremities. Existing medical appliances and external fixation devices often are cumbersome, produce technical artifacts, or are uncomfortable for patients. This paper describes a traction-immobilization device that overcomes many of these difficulties. The authors have used this device successfully in several hundred cases and found that it markedly facilitated patient comfort and throughput. Construction is simple and inexpensive, using materials available in most hardware stores

  12. Device for measuring the temperature of flowing hot gases

    Energy Technology Data Exchange (ETDEWEB)

    Reed, R D

    1977-05-12

    The invention pertains to a device to measure the temperature of a hot gas flowing through a closed tube. The device will have a simple and inexpensive design and avoid heat losses due to heat radiation near the thermal sensor.

  13. Use of static and ac field techniques for measuring mobility and charge lifetimes of radon progeny with a simple device

    International Nuclear Information System (INIS)

    Sapra, B.K.; Mayya, Y.S.

    1998-01-01

    A simple device, based on a modification of the scintillation cell, has been developed for the measurement of radon daughter mobility and charge lifetimes by employing AC and static electric fields. It has a central electrode coated with ZnS and the scintillations are recorded by a PMT unit. The coating is made on the wire, instead of on the inner walls, to improve the relative response of the device with respect to the zero field situation. Radon is drawn into the cell by evacuation techniques. Theoretical formulae, relating the observed count rates to the system parameters and progeny mobilities and charge lifetimes, have been derived under zero field, static and AC field situations. Measurements indicate that the device has very low leak rate (T 1/2 ∼38 days) and the initial environment if maintained for long time. Results of experiments carried out with static and AC fields in most air yielded 218 Po mobilities (1.89 cm 2 /V/s) and charge lifetimes (0.08s) are comparable to those reported in the literature. This demonstrates the feasibility of this technique for future studies with different trace gases. A major advantage of this device as opposed to the conventional spectrometric methods is its simplicity. (author)

  14. Simple overlay device for determining radial head and neck height

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Jun-Gyu; Southgate, Richard D.; Fitzsimmons, James S.; O' Driscoll, Shawn W. [Mayo Clinic, Department of Orthopaedic Surgery, Rochester, MN (United States)

    2010-09-15

    The purpose of this study was to test the hypothesis that a simple overlay device can be used on radiographs to measure radial head and neck height. Thirty anteroposterior elbow radiographs from 30 patients with a clinical diagnosis of lateral epicondylitis were examined to measure radial head and neck height. Three methods using different points along the bicipital tuberosity as a landmark were used. Method 1 used the proximal end of the bicipital tuberosity, method 2 used the most prominent point of the bicipital tuberosity, and method 3 used a simple overlay device (SOD) template that was aligned with anatomic reference points. All measurements were performed three times by three observers to determine interobserver and intraobserver reliability. Intraclass correlation coefficients revealed higher interobserver and intraobserver correlations for the SOD template method than for the other two methods. The 95% limits of agreement between observers were markedly better (-1.8 mm to +1.0 mm) for the SOD template method than for the proximal point method (-3.8 mm to +3.4 mm) or the prominent point method (-5.9 mm to +4.9 mm). We found that the SOD template method was reliable for assessing radial head and neck height. It had less variability than other methods, its 95% limit of agreement being less than 2 mm. This method could be helpful for assessing whether or not the insertion of a radial head prosthesis has resulted in over-lengthening of the radius. (orig.)

  15. Simple overlay device for determining radial head and neck height

    International Nuclear Information System (INIS)

    Moon, Jun-Gyu; Southgate, Richard D.; Fitzsimmons, James S.; O'Driscoll, Shawn W.

    2010-01-01

    The purpose of this study was to test the hypothesis that a simple overlay device can be used on radiographs to measure radial head and neck height. Thirty anteroposterior elbow radiographs from 30 patients with a clinical diagnosis of lateral epicondylitis were examined to measure radial head and neck height. Three methods using different points along the bicipital tuberosity as a landmark were used. Method 1 used the proximal end of the bicipital tuberosity, method 2 used the most prominent point of the bicipital tuberosity, and method 3 used a simple overlay device (SOD) template that was aligned with anatomic reference points. All measurements were performed three times by three observers to determine interobserver and intraobserver reliability. Intraclass correlation coefficients revealed higher interobserver and intraobserver correlations for the SOD template method than for the other two methods. The 95% limits of agreement between observers were markedly better (-1.8 mm to +1.0 mm) for the SOD template method than for the proximal point method (-3.8 mm to +3.4 mm) or the prominent point method (-5.9 mm to +4.9 mm). We found that the SOD template method was reliable for assessing radial head and neck height. It had less variability than other methods, its 95% limit of agreement being less than 2 mm. This method could be helpful for assessing whether or not the insertion of a radial head prosthesis has resulted in over-lengthening of the radius. (orig.)

  16. Temperature responses of a coccolithophorid, Cricosphaera carterae, measured in a simple and inexpensive thermal-gradient device

    International Nuclear Information System (INIS)

    Blankley, W.F.; Lewin, R.A.

    1976-01-01

    An illuminated thermal-gradient device is described which is of simple construction, very low cost, and wide adaptability to various culture vessels. It can be readily adapted for use in crossed gradients with temperature along one axis. The thermal gradient produced depends on several factors including the heat source (one or more incandescent lamps), heat sink (cold air in a refrigerated box or room), and type of culture vessel. By use of the device, the temperature range for growth of Cricosphaera carterae was found to be 10-26 degrees C, with a maximal growth rate at 20 degrees C

  17. A simple encapsulation method for organic optoelectronic devices

    International Nuclear Information System (INIS)

    Sun Qian-Qian; An Qiao-Shi; Zhang Fu-Jun

    2014-01-01

    The performances of organic optoelectronic devices, such as organic light emitting diodes and polymer solar cells, have rapidly improved in the past decade. The stability of an organic optoelectronic device has become a key problem for further development. In this paper, we report one simple encapsulation method for organic optoelectronic devices with a parafilm, based on ternary polymer solar cells (PSCs). The power conversion efficiencies (PCE) of PSCs with and without encapsulation decrease from 2.93% to 2.17% and from 2.87% to 1.16% after 168-hours of degradation under an ambient environment, respectively. The stability of PSCs could be enhanced by encapsulation with a parafilm. The encapsulation method is a competitive choice for organic optoelectronic devices, owing to its low cost and compatibility with flexible devices. (atomic and molecular physics)

  18. Validation of accuracy and reliability of a simple measurement device for the lumber range of motion (SMD-L-ROM)

    International Nuclear Information System (INIS)

    Kato, Nakayuki; Fujiwara, Atsushi; Honda, Toshio; Taneichi, Hiroshi

    2007-01-01

    It is important to evaluate mobility of the lumbar spine for assessment of lumbar spinal disorders and their therapeutic effects. We developed a simple measurement device for the lumbar range of motion (SMD-L-ROM) which can be installed on the trunk. SMD-L-ROM allows to evaluate mobility of the lumbar spine without x-ray exposure. Accuracy and reliability of the measurement device was assessed in this article. SMD-L-ROM comprises two metallic immobilization plates (IPs) with a vertically installed bar and a rubber band for fixation of IP to the trunk. Two IPs were installed at the level of Th12 and the sacrum. Range of motion (ROM) of the lumbar spine was measured by using SMD-L-ROM and radiographic modalities (X-ray and CT). Consistency of the measured values by both of SMD-L-ROM and radiographic modalities was evaluated. Furthermore, inter- and intra-observer agreement of measured values by SMD-L-ROM was assessed. Regarding measurement of ROM, there was a high correlation between SMD-L-ROM and X-ray/CT especially in the sagittal and axial plane. There was no significant difference in the average values of ROM between the two methods. On the other hand, SMD-L-ROM did not detect accurate position of the lumbar spine in all dimensions. There were no inter- and intra-observer errors of measured values by SMD-L-ROM. ROM of the lumbar spine was simply and economically measured with SMD-L-ROM. Accuracy and reliability of SMD-L-ROM was good enough for ROM measurement in the lumbar spine. (author)

  19. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    International Nuclear Information System (INIS)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T.; Guharay, S.K.

    1997-01-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H - ) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  20. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    Energy Technology Data Exchange (ETDEWEB)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T. [National Inst. for Fusion Science, Nagoya (Japan); Guharay, S.K.

    1997-02-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H{sup -}) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  1. A simple nonlinear dynamical computing device

    International Nuclear Information System (INIS)

    Miliotis, Abraham; Murali, K.; Sinha, Sudeshna; Ditto, William L.; Spano, Mark L.

    2009-01-01

    We propose and characterize an iterated map whose nonlinearity has a simple (i.e., minimal) electronic implementation. We then demonstrate explicitly how all the different fundamental logic gates can be implemented and morphed using this nonlinearity. These gates provide the full set of gates necessary to construct a general-purpose, reconfigurable computing device. As an example of how such chaotic computing devices can be exploited, we use an array of these maps to encode data and to process information. Each map can store one of M items, where M is variable and can be large. This nonlinear hardware stores data naturally in different bases or alphabets. We also show how this method of storing information can serve as a preprocessing tool for exact or inexact pattern-matching searches.

  2. Optical interconnection for a polymeric PLC device using simple positional alignment.

    Science.gov (United States)

    Ryu, Jin Hwa; Kim, Po Jin; Cho, Cheon Soo; Lee, El-Hang; Kim, Chang-Seok; Jeong, Myung Yung

    2011-04-25

    This study proposes a simple cost-effective method of optical interconnection between a planar lightwave circuit (PLC) device chip and an optical fiber. It was conducted to minimize and overcome the coupling loss caused by lateral offset which is due to the process tolerance and the dimensional limitation existing between PLC device chips and fiber array blocks with groove structures. A PLC device chip and a fiber array block were simultaneously fabricated in a series of polymer replication processes using the original master. The dimensions (i.e., width and thickness) of the under-clad of the PLC device chip were identical to those of the fiber array block. The PLC device chip and optical fiber were aligned by simple positional control for the vertical direction of the PLC device chip under a particular condition. The insertion loss of the proposed 1 x 2 multimode optical splitter device interconnection was 4.0 dB at 850 nm and the coupling loss was below 0.1 dB compared with single-fiber based active alignment.

  3. Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions

    KAUST Repository

    Li, Erqiang

    2013-12-16

    Droplet-based microfluidic devices have become a preferred versatile platform for various fields in physics, chemistry and biology. Polydimethylsiloxane soft lithography, the mainstay for fabricating microfluidic devices, usually requires the usage of expensive apparatus and a complex manufacturing procedure. Here, we report the design and fabrication of simple and inexpensive microfluidic devices based on microscope glass slides and pulled glass capillaries, for generating monodisperse multiple emulsions. The advantages of our method lie in a simple manufacturing procedure, inexpensive processing equipment and flexibility in the surface modification of the designed microfluidic devices. Different types of devices have been designed and tested and the experimental results demonstrated their robustness for preparing monodisperse single, double, triple and multi-component emulsions. © 2014 IOP Publishing Ltd.

  4. Opto-mechanical design of small infrared cloud measuring device

    Science.gov (United States)

    Zhang, Jiao; Yu, Xun; Tao, Yu; Jiang, Xu

    2018-01-01

    In order to make small infrared cloud measuring device can be well in a wide temperature range and day-night environment, a design idea using catadioptric infrared panoramic imaging optical system and simple mechanical structure for realizing observation clode under all-weather conditions was proposed. Firstly, the optical system of cloud measuring device was designed. An easy-to-use numerical method was proposed to acquire the profile of a catadioptric mirror, which brought the property of equidistance projection and played the most important role in a catadioptric panoramic lens. Secondly, the mechanical structure was studied in detail. Overcoming the limitations of traditional primary mirror support structure, integrative design was used for refractor and mirror support structure. Lastly, temperature adaptability and modes of the mirror support structure were analyzed. Results show that the observation range of the cloud measuring device is wide and the structure is simple, the fundamental frequency of the structure is greater than 100 Hz, the surface precision of the system reflector reaches PV of λ/10 and RMS of λ/40under the load of temperature range - 40 60°C, it can meet the needs of existing meteorological observation.

  5. Simple device to determine the pressure applied by pressure clips for the treatment of earlobe keloids

    Directory of Open Access Journals (Sweden)

    Aashish Sasidharan

    2015-01-01

    Full Text Available Background: Keloids of the ear are common problems. Various treatment modalities are available for the treatment of ear keloids. Surgical excision with intralesional steroid injection along with compression therapy has the least recurrence rate. Various types of devices are available for pressure therapy. Pressure applied by these devices is uncontrolled and is associated with the risk of pressure necrosis. We describe here a simple and easy to use device to measure pressure applied by these clips for better outcome. Objectives: To devise a simple method to measure the pressure applied by various pressure clips used in ear keloid pressure therapy. Materials and Methods: By using a force sensitive resistor (FSR, the pressure applied gets converted into voltage using electrical wires, resistors, capacitors, converter, amplifier, diode, nine-volt (9V cadmium battery and the voltage is measured using a multimeter. The measured voltage is then converted into pressure using pressure voltage graph that depicts the actual pressure applied by the pressure clip. Results: The pressure applied by different clips was variable. The spring clips were adjustable by slight variation in the design whereas the pressure applied by binder clips and magnet discs was not adjustable. Conclusion: The uncontrolled/suboptimal pressure applied by certain pressure clips can be monitored to provide optimal pressure therapy in ear keloid for better outcome.

  6. Utility of a simple lighting device to improve chest compressions learning.

    Science.gov (United States)

    González-Calvete, L; Barcala-Furelos, R; Moure-González, J D; Abelairas-Gómez, C; Rodríguez-Núñez, A

    2017-11-01

    The recommendations on cardiopulmonary resuscitation (CPR) emphasize the quality of the manoeuvres, especially chest compressions (CC). Audiovisual feedback devices could improve the quality of the CC during CPR. The aim of this study was to evaluate the usefulness of a simple lighting device as a visual aid during CPR on a mannequin. Twenty-two paediatricians who attended an accredited paediatric CPR course performed, in random order, 2min of CPR on a mannequin without and with the help of a simple lighting device, which flashes at a frequency of 100 cycles per minute. The following CC variables were analyzed using a validated compression quality meter (CPRmeter ® ): depth, decompression, rate, CPR time and percentage of compressions. With the lighting device, participants increased average quality (60.23±54.50 vs. 79.24±9.80%; P=.005), percentage in target depth (48.86±42.67 vs. 72.95±20.25%; P=.036) and rate (35.82±37.54 vs. 67.09±31.95%; P=.024). A simple light device that flashes at the recommended frequency improves the quality of CC performed by paediatric residents on a mannequin. The usefulness of this CPR aid system should be assessed in real patients. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. A simple optical fibre-linked remote control system for multiple devices

    Indian Academy of Sciences (India)

    We report on the development of a simple control system which can handle multiple devices through an optical fibre data link. The devices are controlled using a set of DACs through serial data communication via a serial port of a PC. Serial data from the PC get converted to parallel mode using a homemade “serial in ...

  8. Position measuring device

    International Nuclear Information System (INIS)

    Maeda, Kazuyuki; Takahashi, Shuichi; Maruyama, Mayumi

    1998-01-01

    The present invention provides a device capable of measuring accurate position and distance easily even at places where operator can not easily access, such as cell facilities for vitrifying radioactive wastes. Referring to a case of the vitrifying cell, an objective equipment settled in the cell is photographed by a photographing device. The image is stored in a position measuring device by way of an image input device. After several years, when the objective equipment is exchanged, a new objective equipment is photographed by a photographing device. The image is also stored in the position measuring device. The position measuring device compares the data of both of the images on the basis of pixel unit. Based on the image of the equipment before the exchange as a reference, extent of the displacement of the installation position of the equipment on the image after the exchange caused by installation error and manufacturing error is determined to decide the position of the equipment after exchange relative to the equipment before exchange. (I.S.)

  9. A simple, semi-quantitative method for measuring pulsed soft x-rays

    International Nuclear Information System (INIS)

    Takahama, Y.; Du, J.; Yanagidaira, T.; Hirano, K.

    1993-01-01

    A simple semi-quantitative measurement and image processing system for pulsed soft X-rays with a time and spatial resolution is proposed. Performance of the system is examined using a cylindrical soft X-ray source generated with a plasma device. The system consists of commercial facilities which are easily obtained such as a microchannel plate-phosphor screen combination, a CCD camera, an image memory board and a personal computer. To make a quantitative measurement possible, the image processing and observation of the phosphor screen current are used in conjunction. (author)

  10. A simple technique for measurement of pressure in the tympanitic rumen of cattle.

    Science.gov (United States)

    Turner, C B; Whyte, T D

    1978-05-13

    The construction and method of use of a simple device for the non-invasive measurement of intra-rumenal pressure is outlined. Results obtained from calves suffering from increased intra-rumenal pressure (bloat) are shown. The method is capable of quantifying pressures involved in bloat and could be used to augment the visual assessment of bloat scoring.

  11. Evaluation of a new simple collection device for sampling of microparticles in exhaled breath.

    Science.gov (United States)

    Seferaj, Sabina; Ullah, Shahid; Tinglev, Åsa; Carlsson, Sten; Winberg, Jesper; Stambeck, Peter; Beck, Olof

    2018-03-12

    The microparticle fraction of exhaled breath is of interest for developing clinical biomarkers. Exhaled particles may contain non-volatile components from all parts of the airway system, formed during normal breathing. This study aimed to evaluate a new, simple sampling device, based on impaction, for collecting microparticles from exhaled breath. Performance of the new device was compared with that of the existing SensAbues membrane filter device. The analytical work used liquid chromatography-tandem mass spectrometry methods. The new device collected three subsamples and these were separately analysed from eight individuals. No difference was observed between the centre position (0.91 ng/sample) and the side positions (1.01 ng/sample) using major phosphatidylcholine (PC) 16:0/16:0 as the analyte. Exhaled breath was collected from eight patients on methadone maintenance treatment. The intra-individual variability in measured methadone concentration between the three collectors was 8.7%. In another experiment using patients on methadone maintenance treatment, the sampling efficiency was compared with an established filter device. Compared to the existing device, the efficiency of the new device was 121% greater for methadone and 1450% greater for DPPC. The data from lipid analysis also indicated that a larger fraction of the collected material was from the distal parts. Finally, a study using an optical particle counter indicated that the device preferentially collects the larger particle fraction. In conclusion, this study demonstrates the usefulness of the new device for collecting non-volatile components from exhaled breath. The performance of the device was superior to the filter device in several aspects.

  12. Simple and inexpensive microfluidic devices for the generation of monodisperse multiple emulsions

    KAUST Repository

    Li, Erqiang; Zhang, Jiaming; Thoroddsen, Sigurdur T

    2013-01-01

    of expensive apparatus and a complex manufacturing procedure. Here, we report the design and fabrication of simple and inexpensive microfluidic devices based on microscope glass slides and pulled glass capillaries, for generating monodisperse multiple emulsions

  13. Control device intended for a gamma radiation measuring instrument

    International Nuclear Information System (INIS)

    1976-01-01

    This invention concerns a monitoring device for a gamma radiation measuring instrument or radiation meter, in which the radiation to be measured brings about, inter alia, the ionisation of a gas and the generation of current pulses. The dial of this meter is generally calibrated in roentgens per hour, i.e. in radiation rate units. This instrument of very simple design is remarkable for its operating reliability. Preferably placed at the inlet to a radioactive area, it enables every user of a ratemeter to check, over the entire measuring range of this instrument, its proper operation prior to entering the area. To this effect, the monitoring device in question has a thick wall lead castle, having an internal cavity in which is mounted a radioactive source delivering a gamma radiation with given constant characteristics, through a measurement window closed by a calibrated plug. Lead doors articulated on the castle can be superimposed on this window to bring about a given attenuation of the radiation coming from the source and delivered to the exterior of the castle [fr

  14. Evaluation efficiency for mobile as discharge measurement device for partially filled circular channel

    Directory of Open Access Journals (Sweden)

    I.M.H. Rashwan

    2013-06-01

    Full Text Available Discharge measurement is an important step in engineering applications such as sewerage system, irrigation and drainage system. Mobile flume is a simple and low-cost discharge measuring device constructed of two pieces of pipes, one installed vertically inside the other. The circular mobile flume depends on the concept of developing a contracted zone to have a control section. To evaluate the efficiency of this type of device mathematical and experimental studies are presented. Specific energy, discharge and Froude number equations are used to develop mathematical model. Experimental work is carried out to measure the discharge values corresponding to the specific energy values. The experimental data is used to evaluate the mobile flume as a device to measure discharge. A new equation for the discharge coefficient is presented. This equation can be used to determined accurate discharge with knowing the contraction ratio and measured specific energy.

  15. Neutron measuring device

    International Nuclear Information System (INIS)

    Hatayama, Akiyoshi; Seki, Eiji; Kita, Yoshio; Nishitani, Takeo.

    1993-01-01

    The device of the present invention concerns measurement for neutrons in a tokamak type thermonuclear device and it can measure total amount of generated neutrons accurately throughout the operation period even if an error is caused in counted values by plasma disruption. That is, the device comprises (1) a means for detecting presence or absence of occurrence of plasma disruption and the time for the initiation of the occurrence, (2) a first data processing means for processing detection signals, (3) a means for detecting neutrons generated in plasmas and (4) a second data processing means for calculating integrated values for the number of neutrons generated from the start to the completion of electric discharge when no disruption occurs and calculating integrated values for the number of generated neutrons from the start of electric discharge to the time at the initiation of occurrence of the disruption when disruption is present. In the thus constituted device, even if an error is caused by frequent occurrence of plasma disruption, total time integrated amount of neutrons generated in the plasmas can be measured accurately. (I.S.)

  16. Simple Device for Treating Prolapsing Loop Colostomy

    Directory of Open Access Journals (Sweden)

    Ming-Yu Hsieh

    2006-03-01

    Full Text Available Stoma prolapse is a common complication of intestinal stoma. Although various surgical methods yield satisfactory results, nonsurgical treatment may be better for a temporary stoma. We report a case of a patient with a distal limb prolapse of a right transverse colostomy who received nonsurgical treatment with satisfactory results. For the treatment of a temporary transverse loop colostomy with distal limb prolapse, we designed a simple device consisting of a pediatric plastic medicine cup, which was rolled into a towel to shape the bottom of the cup into a compressor. The towel was put on the stoma outside of the colostomy bag with the compressor above the prolapsing limb of the colostomy. An abdominal binder was applied to fix the towel.

  17. A simple suture-retrieval device for the placement of u-stitches during laparoscopic gastrostomy.

    Science.gov (United States)

    Mattei, Peter

    2009-02-01

    During minimally invasive operations, it is sometimes necessary to retrieve the end of a suture or a suture needle and bring it out through the abdominal wall. Using a standard needle and a length of suture, we have developed a simple device that allows the retrieval of a suture end during minimally invasive operations that require the placement of U-or stay stitches. The author has used the device described during more than 100 laparoscopic gastrostomy placement procedures and other operations involving the placement of U- or stay stitches with excellent results and no complications. Using a beveled hollow-bore needle and a loop of polypropylene suture, one can construct a simple device that allows the retrieval of a suture from within a body cavity during minimally invasive surgery, making the placement of U- and stay stitches easier and more precise.

  18. An easy-to-use microfluidic interconnection system to create quick and reversibly interfaced simple microfluidic devices

    DEFF Research Database (Denmark)

    Pfreundt, Andrea; Andersen, Karsten Brandt; Dimaki, Maria

    2015-01-01

    The presented microfluidic interconnection system provides an alternative for the individual interfacing of simple microfluidic devices fabricated in polymers such as polymethylmethacrylate, polycarbonate and cyclic olefin polymer. A modification of the device inlet enables the direct attachment...... pressures above 250 psi and therefore supports applications with high flow rates or highly viscous fluids. The ease of incorporation, configuration, fabrication and use make this interconnection system ideal for the rapid prototyping of simple microfluidic devices or other integrated systems that require...... microfluidic interfaces. It provides a valuable addition to the toolbox of individual and small arrays of connectors suitable for micromachined or template-based injection molded devices since it does not require protruding, threaded or glued modifications on the inlet and avoids bulky and expensive fittings....

  19. Simple emittance measurement of H- beams from a large plasma source

    International Nuclear Information System (INIS)

    Guharay, S.K.; Tsumori, K.; Hamabe, M.; Takeiri, Y.; Kaneko, O.; Kuroda, T.

    1996-03-01

    An emittance meter is developed using pepper-pot method. Kapton foils are used to detect intensity distributions of small beamlets at the 'image' plane of the pepper-pot. Emittance of H - beams from a large plasma source for the neutral beam injector of the Large Helical Device (LHD) has been measured. The normalized emittance (95%) of a 6 mA H - beam with emission current density of about 10 mA/cm 2 is ∼0.59 mm mrad. The present system is very simple, and it eliminates many complexities of the existing schemes. (author)

  20. A comparative study of the Podotrack, a simple semiquantitative plantar pressure measuring device, and the optical pedobarograph in the assessment of pressures under the diabetic foot.

    Science.gov (United States)

    van Schie, C H; Abbott, C A; Vileikyte, L; Shaw, J E; Hollis, S; Boulton, A J

    1999-02-01

    To test the Podotrack, a simple inexpensive semiquantitative footprint mat, for potential use as a screening tool for high plantar pressures, against the optical pedobarograph (a computerized device). The Podotrack was superimposed on the pedobarograph for simultaneous measurement of pressures from both systems. Three independent observers quantified the pressures of Podotrack footprints from healthy controls and diabetic patients, both before (n=164) and after (n=183) training. The sensitivity of the Podotrack to identify high pressure areas measured by the pedobarograph (> 12.3 kg/cm2) was 78.7%, 45.8% and 44.3% (observer A, B and C) before training, but improved to 96.2%, 92.4% and 91.1% after training (P<0.01). Specificity for all three observers was more than 90% before and after training. Inter-observer agreement improved significantly after training (P<0.001). After a simple training of the observers, the Podotrack identified approximately all high pressure areas, suggesting that the Podotrack could be a useful screening tool to identify areas at risk of ulceration in diabetic patients. We recommend a standard training package for new Podotrack users, to optimize identification of diabetic patients at risk of foot ulceration.

  1. Method and device for bio-impedance measurement with hard-tissue applications

    International Nuclear Information System (INIS)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-01-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kΩ to 10 MΩ across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kΩ to 10 MΩ and from 20 pF to 100 pF, are discussed

  2. Method and device for bio-impedance measurement with hard-tissue applications.

    Science.gov (United States)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-06-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kOmega to 10 MOmega across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kOmega to 10 MOmega and from 20 pF to 100 pF, are discussed.

  3. Piezoelectric translator. A simple and inexpensive device to move microelectrodes and micropipettes small distances rapidly.

    Science.gov (United States)

    Lederer, W J

    1983-09-01

    A device is described that is capable of rapidly moving microelectrodes and micropipettes over distances up to 15 mu. This piezoelectric transLator uses the diaphragm from virtually any available piezoelectric buzzer in combination with simple physical support and drive electronics. All of the necessary details for the construction of this small device are presented. Each finished unit is about 2 cm long with a diameter of 2 cm and can be readily adapted to existing manipulators. The translator has been found useful in aiding the independent penetration by one or more microelectrodes of single cells or of more complicated multicellular preparations (including those that lie behind a connective tissue layer). This new device offers fine control of microelectrode motion that cannot be obtained by the other methods used to aid microelectrode and micropipette penetration of cell membranes (e.g. capacitance overcompensation--"ringing in"' or "tickling"--or tapping the manipulator base). Finally, the device described in this paper is extremely simple and inexpensive to build.

  4. An easy way to measure accurately the direct magnetoelectric voltage coefficient of thin film devices

    Energy Technology Data Exchange (ETDEWEB)

    Poullain, Gilles, E-mail: gilles.poullain@ensicaen.fr; More-Chevalier, Joris; Cibert, Christophe; Bouregba, Rachid

    2017-01-15

    Tb{sub x}Dy{sub 1−x}Fe{sub 2}/Pt/Pb(Zr{sub x}, Ti{sub 1−x})O{sub 3} thin films were grown on Pt/TiO{sub 2}/SiO{sub 2}/Si substrate by multi-target sputtering. The magnetoelectric voltage coefficient α{sup Η}{sub ΜΕ} was determined at room temperature using a lock-in amplifier. By adding, in series in the circuit, a capacitor of the same value as that of the device under test, we were able to demonstrate that the magnetoelectric device behaves as a voltage source. Furthermore, a simple way to subtract the stray voltage arising from the flow of eddy currents in the measurement set-up, is proposed. This allows the easy and accurate determination of the true magnetoelectric voltage coefficient. A large α{sup Η}{sub ΜΕ} of 8.3 V/cm. Oe was thus obtained for a Terfenol-D/Pt/PZT thin film device, without DC magnetic field nor mechanical resonance. - Highlights: • Magnetoelectric device behaves as a voltage source. • A simple way to subtract eddy currents during the measurement, is proposed.

  5. A New Metre for Cheap, Quick, Reliable and Simple Thermal Transmittance (U-Value) Measurements in Buildings.

    Science.gov (United States)

    Andújar Márquez, José Manuel; Martínez Bohórquez, Miguel Ángel; Gómez Melgar, Sergio

    2017-09-03

    This paper deals with the thermal transmittance measurement focused on buildings and specifically in building energy retrofitting. Today, if many thermal transmittance measurements in a short time are needed, the current devices, based on the measurement of the heat flow through the wall, cannot carry out them, except if a great amount of devices are used at once along with intensive and tedious post-processing and analysis work. In this paper, from well-known physical laws, authors develop a methodology based on three temperatures measurements, which is implemented by a novel thermal transmittance metre. The paper shows its development step by step. As a result the developed device is modular, scalable, and fully wireless; it is capable of taking as many measurements at once as user needs. The developed system is compared working together on a same test to the currently used one based on heat flow. The results show that the developed metre allows carrying out thermal transmittance measurements in buildings in a cheap, quick, reliable and simple way.

  6. A simple device for the stereoscopic display of 3D CT images

    International Nuclear Information System (INIS)

    Haveri, M.; Suramo, I.; Laehde, S.; Karhula, V.; Junila, J.

    1997-01-01

    We describe a simple device for creating true 3D views of image pairs obtained at 3D CT reconstruction. The device presents the images in a slightly different angle of view for the left and the right eyes. This true 3D viewing technique was applied experimentally in the evaluation of complex acetabular fractures. Experiments were also made to determine the optimal angle between the images for each eye. The angle varied between 1 and 7 for different observers and also depended on the display field of view used. (orig.)

  7. Suture fixation of migrated septal occluder device to prevent further migration: a simple surgical technique

    Directory of Open Access Journals (Sweden)

    Mohite Prashant N

    2013-01-01

    Full Text Available Abstract As the use of percutaneous intervention is increasing for the closure of the atrial septal defect, the procedure related complications are also on rise, migration of the device being most common. The migrated devices with failed percutaneous retrieval must be removed surgically under cardiopulmonary bypass. During establishment of cardiopulmonary bypass, the handling of heart may cause further migration of the device into other chambers of heart which leads to difficulty in finding and retrieval of the device. The authors propose a simple and unique technique to prevent further migration of the septal occluder device.

  8. A simple miniature device for wireless stimulation of neural circuits in small behaving animals.

    Science.gov (United States)

    Zhang, Yisi; Langford, Bruce; Kozhevnikov, Alexay

    2011-10-30

    The use of wireless neural stimulation devices offers significant advantages for neural stimulation experiments in behaving animals. We demonstrate a simple, low-cost and extremely lightweight wireless neural stimulation device which is made from off-the-shelf components. The device has low power consumption and does not require a high-power RF preamplifier. Neural stimulation can be carried out in either a voltage source mode or a current source mode. Using the device, we carry out wireless stimulation in the premotor brain area HVC of a songbird and demonstrate that such stimulation causes rapid perturbations of the acoustic structure of the song. Published by Elsevier B.V.

  9. Radiation ray measuring device

    International Nuclear Information System (INIS)

    Maekawa, Tatsuyuki; Ida, Masaki.

    1997-01-01

    The present invention provides a chained-radiation ray monitoring system which can be applied to an actual monitoring system of a nuclear power plant or the like. Namely, this device comprises a plurality of scintillation detectors. Each of the detectors has two light take-out ports for emitting light corresponding to radiation rays irradiated from the object of the measurement to optical fibers. In addition, incident light from the optical fiber by way of one of the light take-out optical ports is transmitted to the other of the ports and sent from the other optical port to the fibers. Plurality sets of measuring systems are provided in which each of the detectors are disposed corresponding to a plurality of objects to be measured. A signal processing device is (1) connected with optical fibers of plurality sets of measuring systems in conjunction, (2) detects the optical pulses inputted from the optical fibers to identify the detector from which the optical pulses are sent and (3) measures the amount of radiation rays detected by the identified detector. As a result, the device of the present invention can form a measuring system with redundancy. (I.S.)

  10. Temperature measuring device

    International Nuclear Information System (INIS)

    Brixy, H.

    1977-01-01

    The temperature measuring device is equipped with an electric resistor installed within a metal shroud tube so as to be insulated from it, the noise voltage of which resistor is fed to a measuring unit. The measuring junctions of one or two thermocouples are connected with the electric resistor and the legs of one or both thermocouples can be connected to the measuring unit by means of a switch. (orig.) [de

  11. An unheated permeation device for calibrating atmospheric VOC measurements

    Directory of Open Access Journals (Sweden)

    J. Brito

    2011-10-01

    Full Text Available The development of an unpowered permeation device for continuous calibration of in-situ instruments measuring atmospheric volatile organic compounds (VOCs is described. Being lightweight and compact, and containing only negligible amounts of chemicals, the device is especially suited for field use such as on board aircraft. Its speciality is to maintain the permeation process in thermal equilibrium, so that the instantaneous permeation rate can be ascribed to a simple temperature measurement. This equilibrium state is maintained by a combination of three features: (i a thin PTFE membrane as permeation medium which guarantees short stabilization times, (ii a water bath as heat buffer, and (iii a vacuum-panel based insulation, in which features (ii and (iii minimize temperature drifts to ~30 mK h−1 per Kelvin temperature difference to the environment. The respective uncertainty of the permeation rate due to thermal non-equilibrium is kept below 1%. An extensive theory part details the major permeation processes of gases through porous polymers, being Fick's diffusion, Knudsen flow, and viscous flow. Both the measured stabilization time and the measured temperature dependence of the permeation rate independently indicate that the permeation can be described by a viscous flow model, where diffusion of the gas molecules in large pores (having a diameter of >0.05 μm dominates.

  12. Fabrication of an inexpensive photosensitive flow through device for turbidity measurement

    International Nuclear Information System (INIS)

    Morco, Ryan P.; Dawal, Micah S.; Sucgang, Raymond J.

    2014-01-01

    The aim of this study is the construction of a portable, simple to use, on-line photosensitive device which measures turbidity in water. The turbidity measuring device uses a light emitting diode, LED, light source shining on a light dependent resistor, LDR, which is connected in series to a circuit supplying a constant voltage and a digital voltmeter, DVM. Light shine through a tube containing the sample, and onto a photosensitive circuit. A clear tube of water is the BLANK and has zero absorbance. A fraction of the incident light that i obstructed by the turbidity of the sample can be used for calculable determination of turbidity in water. The turbidity is related to the absorbance reading, following Beer's law. The amount of incident and transmitted light are expressed in voltage units, by a voltmeter. The sample is delivered into the sampling chamber by a rubber tubing attached to a power head submersible pump which is immersed in the pool of water to be sampled. The instrument shows excellent response over the range o turbidity values (5NTU to 180 NTU). Linearity (R 2= 0.95) has been achieved using the device, working with 6 trials per particular NTU value. The NTU readings of the urbidity meter were calibrated against solutions of varying NTU's measured using a HORIBA multi-parameter probe. The other features of the device include: simplicity of operation, low-cost, rugged, handy and can be used in on-line and flow mode applications. (author)

  13. A simple method of fabricating mask-free microfluidic devices for biological analysis.

    KAUST Repository

    Yi, Xin

    2010-09-07

    We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper to form intricate patterns and differently configured channels for specific purposes. Bonded with cyanoacrylate-based resin, the prepared paper sheet is sandwiched between glass slides (hydrophilic) or polymer-based plates (hydrophobic) to obtain a multilayer structure. In order to examine the chip\\'s biocompatibility and applicability, protein concentration was measured while DNA capillary electrophoresis was carried out, and both of them show positive results. With the utilization of direct laser cutting and one-step gas-sacrificing techniques, the whole fabrication processes for complicated 2D and 3D microfluidic devices are shorten into several minutes which make it a good alternative of poly(dimethylsiloxane) microfluidic chips used in biological analysis researches.

  14. 21 CFR 864.6400 - Hematocrit measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematocrit measuring device. 864.6400 Section 864.6400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Manual Hematology Devices § 864.6400 Hematocrit measuring...

  15. Can Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review.

    Science.gov (United States)

    Georgiou, Konstantinos; Larentzakis, Andreas V; Khamis, Nehal N; Alsuhaibani, Ghadah I; Alaska, Yasser A; Giallafos, Elias J

    2018-03-01

    A growing number of wearable devices claim to provide accurate, cheap and easily applicable heart rate variability (HRV) indices. This is mainly accomplished by using wearable photoplethysmography (PPG) and/or electrocardiography (ECG), through simple and non-invasive techniques, as a substitute of the gold standard RR interval estimation through electrocardiogram. Although the agreement between pulse rate variability (PRV) and HRV has been evaluated in the literature, the reported results are still inconclusive especially when using wearable devices. The purpose of this systematic review is to investigate if wearable devices provide a reliable and precise measurement of classic HRV parameters in rest as well as during exercise. A search strategy was implemented to retrieve relevant articles from MEDLINE and SCOPUS databases, as well as, through internet search. The 308 articles retrieved were reviewed for further evaluation according to the predetermined inclusion/exclusion criteria. Eighteen studies were included. Sixteen of them integrated ECG - HRV technology and two of them PPG - PRV technology. All of them examined wearable devices accuracy in RV detection during rest, while only eight of them during exercise. The correlation between classic ECG derived HRV and the wearable RV ranged from very good to excellent during rest, yet it declined progressively as exercise level increased. Wearable devices may provide a promising alternative solution for measuring RV. However, more robust studies in non-stationary conditions are needed using appropriate methodology in terms of number of subjects involved, acquisition and analysis techniques implied.

  16. Development of a wireless blood pressure measuring device with smart mobile device.

    Science.gov (United States)

    İlhan, İlhan; Yıldız, İbrahim; Kayrak, Mehmet

    2016-03-01

    Today, smart mobile devices (telephones and tablets) are very commonly used due to their powerful hardware and useful features. According to an eMarketer report, in 2014 there were 1.76 billion smartphone users (excluding users of tablets) in the world; it is predicted that this number will rise by 15.9% to 2.04 billion in 2015. It is thought that these devices can be used successfully in biomedical applications. A wireless blood pressure measuring device used together with a smart mobile device was developed in this study. By means of an interface developed for smart mobile devices with Android and iOS operating systems, a smart mobile device was used both as an indicator and as a control device. The cuff communicating with this device through Bluetooth was designed to measure blood pressure via the arm. A digital filter was used on the cuff instead of the traditional analog signal processing and filtering circuit. The newly developed blood pressure measuring device was tested on 18 patients and 20 healthy individuals of different ages under a physician's supervision. When the test results were compared with the measurements made using a sphygmomanometer, it was shown that an average 93.52% accuracy in sick individuals and 94.53% accuracy in healthy individuals could be achieved with the new device. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  17. Fabrication of a Paper-Based Microfluidic Device to Readily Determine Nitrite Ion Concentration by Simple Colorimetric Assay

    Science.gov (United States)

    Wang, Bo; Lin, Zhiqiang; Wang, Min

    2015-01-01

    Paper-based microfluidic devices (µPAD) are a burgeoning platform of microfluidic analysis technology. The method described herein is for use in undergraduate and high school chemistry laboratories. A simple and convenient µPAD was fabricated by easy patterning of filter paper using a permanent marker pen. The usefulness of the device was…

  18. 32 CFR 634.27 - Speed-measuring devices.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Speed-measuring devices. 634.27 Section 634.27 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) LAW ENFORCEMENT AND CRIMINAL INVESTIGATIONS MOTOR VEHICLE TRAFFIC SUPERVISION Traffic Supervision § 634.27 Speed-measuring devices. Speed-measuring devices will be...

  19. Propagation Measurements for Device-to-Device Communication in Forest Terrain

    DEFF Research Database (Denmark)

    Hejselbæk, Johannes; Nielsen, Jesper Ødum; Drewes, Christian

    2018-01-01

    In this paper, we present a measurement campaign conducted in forest terrain with focus on path-loss. The aim of the measurement campaign is to study the coverage in a Device-to-Device (D2D) communication scenario. The measurement campaign was conducted in the LTE band 8 at 917.5 MHz...... with measurement ranges extending to more than 2.5 km. The measurements have been conducted using a purpose-developed measurement system with a dynamic range of 180 dB. The measurements showed that a D2D system with transmit and receive antenna at heights of 1.5 m could achieve a range of approximately 2 km using...

  20. A Printed Equilibrium Dialysis Device with Integrated Membranes for Improved Binding Affinity Measurements.

    Science.gov (United States)

    Pinger, Cody W; Heller, Andrew A; Spence, Dana M

    2017-07-18

    Equilibrium dialysis is a simple and effective technique used for investigating the binding of small molecules and ions to proteins. A three-dimensional (3D) printer was used to create a device capable of measuring binding constants between a protein and a small ion based on equilibrium dialysis. Specifically, the technology described here enables the user to customize an equilibrium dialysis device to fit their own experiments by choosing membranes of various material and molecular-weight cutoff values. The device has dimensions similar to that of a standard 96-well plate, thus being amenable to automated sample handlers and multichannel pipettes. The device consists of a printed base that hosts multiple windows containing a porous regenerated-cellulose membrane with a molecular-weight cutoff of ∼3500 Da. A key step in the fabrication process is a print-pause-print approach for integrating membranes directly into the windows subsequently inserted into the base. The integrated membranes display no leaking upon placement into the base. After characterizing the system's requirements for reaching equilibrium, the device was used to successfully measure an equilibrium dissociation constant for Zn 2+ and human serum albumin (K d = (5.62 ± 0.93) × 10 -7 M) under physiological conditions that is statistically equal to the constants reported in the literature.

  1. A simple device to protect against osteoradionecrosis induced by interstitial irradiation

    International Nuclear Information System (INIS)

    Levendag, P.C.; Visch, L.L.; Driver, N.

    1990-01-01

    The incidence of osteoradionecrosis has declined since the introduction of preventive oral hygiene programs and meticulous dental evaluations before and after irradiation. Nevertheless, radiation dose per se still remains an important factor in osteoradionecrosis. Interstitial radiation has received much attention in the past decade since the use of flexible afterloading systems. It has become common practice in large oncology centers to implant radiation carriers in bulky tumor in the oral cavity and/or oropharynx. For interstitial radiation, with or without external radiation, minimal tumor doses are often cited to be more than 70 Gy. Unfortunately, if the mandible receives more than 70 Gy, it is at risk for the development of osteoradionecrosis. Therefore a simple protective lead device has been designed for routine use in brachytherapy in oral cavity tumors to reduce the dose to the mandible. This device will diminish the potential risk of osteoradionecrosis development

  2. Coating thickness measuring device

    International Nuclear Information System (INIS)

    Joffe, B.B.; Sawyer, B.E.; Spongr, J.J.

    1984-01-01

    A device especially adapted for measuring the thickness of coatings on small, complexly-shaped parts, such as, for example, electronic connectors, electronic contacts, or the like. The device includes a source of beta radiation and a radiation detector whereby backscatter of the radiation from the coated part can be detected and the thickness of the coating ascertained. The radiation source and detector are positioned in overlying relationship to the coated part and a microscope is provided to accurately position the device with respect to the part. Means are provided to control the rate of descent of the radiation source and radiation detector from its suspended position to its operating position and the resulting impact it makes with the coated part to thereby promote uniformity of readings from operator to operator, and also to avoid excessive impact with the part, thereby improving accuracy of measurement and eliminating damage to the parts

  3. Inducer Hydrodynamic Load Measurement Devices

    Science.gov (United States)

    Skelley, Stephen E.; Zoladz, Thomas F.

    2002-01-01

    Marshall Space Flight Center (MSFC) has demonstrated two measurement devices for sensing and resolving the hydrodynamic loads on fluid machinery. The first - a derivative of the six component wind tunnel balance - senses the forces and moments on the rotating device through a weakened shaft section instrumented with a series of strain gauges. This "rotating balance" was designed to directly measure the steady and unsteady hydrodynamic loads on an inducer, thereby defining both the amplitude and frequency content associated with operating in various cavitation modes. The second device - a high frequency response pressure transducer surface mounted on a rotating component - was merely an extension of existing technology for application in water. MSFC has recently completed experimental evaluations of both the rotating balance and surface-mount transducers in a water test loop. The measurement bandwidth of the rotating balance was severely limited by the relative flexibility of the device itself, resulting in an unexpectedly low structural bending mode and invalidating the higher frequency response data. Despite these limitations, measurements confirmed that the integrated loads on the four-bladed inducer respond to both cavitation intensity and cavitation phenomena. Likewise, the surface-mount pressure transducers were subjected to a range of temperatures and flow conditions in a non-rotating environment to record bias shifts and transfer functions between the transducers and a reference device. The pressure transducer static performance was within manufacturer's specifications and dynamic response accurately followed that of the reference.

  4. Measurement-Device-Independent Approach to Entanglement Measures

    Science.gov (United States)

    Shahandeh, Farid; Hall, Michael J. W.; Ralph, Timothy C.

    2017-04-01

    Within the context of semiquantum nonlocal games, the trust can be removed from the measurement devices in an entanglement-detection procedure. Here, we show that a similar approach can be taken to quantify the amount of entanglement. To be specific, first, we show that in this context, a small subset of semiquantum nonlocal games is necessary and sufficient for entanglement detection in the local operations and classical communication paradigm. Second, we prove that the maximum payoff for these games is a universal measure of entanglement which is convex and continuous. Third, we show that for the quantification of negative-partial-transpose entanglement, this subset can be further reduced down to a single arbitrary element. Importantly, our measure is measurement device independent by construction and operationally accessible. Finally, our approach straightforwardly extends to quantify the entanglement within any partitioning of multipartite quantum states.

  5. Concordance and discriminatory power of cough measurement devices for individuals with Parkinson disease.

    Science.gov (United States)

    Silverman, Erin P; Carnaby-Mann, Giselle; Pitts, Teresa; Davenport, Paul; Okun, Michael S; Sapienza, Christine

    2014-05-01

    Dysphagia and aspiration pneumonia are two causes of morbidity in Parkinson disease (PD). In PD, impaired airway clearance can lead to penetration of foreign material, resulting in a high prevalence of aspiration pneumonia and death. This study examines three different devices for measurement of peak airflow during voluntary cough in healthy control subjects and those with PD. Two simple and low-cost devices for measuring peak cough airflow were compared with the "gold standard" pneumotachograph. Thirty-five healthy control subjects and 35 individuals with PD produced voluntary cough at three perceived strengths (weak, moderate, and strong cough) for each of the three devices. A significant difference in mean peak cough airflow was demonstrated for disease (F[1,56] = 4.0, P < .05) and sex (F[1,56] = 9.59, P < .003) across devices. The digital and analog meters were comparable to the gold standard demonstrating no significant difference (statistical) by device (digital vs analog) in receiver operating characteristic curve analysis. Both devices were discriminative of the presence of PD. The analog and digital peak airflow meters are suitable alternatives to the gold standard pneumotachograph due to their low cost, portability, ease of use, and high sensitivity relative to normative peak cough airflows. Voluntary cough airflow measures may serve as a noninvasive means of screening for aspiration risk in target populations. Additionally, quantification of cough strength through use of predetermined limens for weak, moderate, and strong cough may assist clinicians in better describing and tracking cough strength as a contributing factor to aspiration risk.

  6. Evaluation of spectrum measurement devices for operational use

    CERN Document Server

    Devine, R T; Gray, D W; Seagraves, D T; Olsher, R H; Johnson, J P

    2002-01-01

    Several neutron spectrometers manufactured by Bubble Technology Industries (BTI) were tested and evaluated in a variety of neutron fields. Findings and conclusions are presented for the following BTI instruments: a modification of the Rotational Spectrometer (ROSPEC) that includes a thermal and epithermal capability, the Simple Scintillation Spectrometer that is used in conjunction with the ROSPEC to extend its high-energy range, and the MICROSPEC N-Probe which is capable of providing a crude spectrum over the energy range from thermal to 18 MeV. The main objective of these measurements was to determine the accuracy of both the energy spectrum and dose equivalent information generated by these devices. In addition, the dose response of the Wide-Energy Neutron Detection Instrument (WENDI-II) was measured in all neutron fields relative to a bare sup 2 sup 5 sup 2 Cf calibration. The performance of the WENDI-II rem meter was compared to the dose information generated by the neutron spectrometers. The instruments...

  7. Sensitive and simple method for measuring wire tensions

    International Nuclear Information System (INIS)

    Atac, M.; Mishina, M.

    1982-08-01

    Measuring tension of wires in drift chambers and multiwire proportional chambers after construction is an important process because sometimes wires get loose after soldering, crimping or glueing. One needs to sort out wires which have tensions below a required minimum value to prevent electrostatic instabilities. There have been several methods reported on this subject in which the wires were excited either with sinusoidal current under magnetic field or with sinusoidal voltage electrostatically coupled to the wire, searching for a resonating frequency with which the wires vibrate mechanically. Then the vibration is detected either visually, optically or with magnetic pick-up directly touching the wires. Any of these is only applicable to the usual multiwire chamber which has open access to the wire plane. They also need fairly large excitation currents to induce a detectable vibration to the wires. Here we report a very simple method that can be used for any type of wire chamber or proportional tube system for measuring wire tension. Only a very small current is required for the wire excitation to obtain a large enough signal because it detects the induced emf voltage across a wire. A sine-wave oscillator and a digital voltmeter are sufficient devices aside from a permanent magnet to provide the magnetic field around the wire. A useful application of this method to a large system is suggested

  8. Near instrument-free, simple molecular device for rapid detection of herpes simplex viruses.

    Science.gov (United States)

    Lemieux, Bertrand; Li, Ying; Kong, Huimin; Tang, Yi-Wei

    2012-06-01

    The first near instrument-free, inexpensive and simple molecular diagnostic device (IsoAmp HSV, BioHelix Corp., MA, USA) recently received US FDA clearance for use in the detection of herpes simplex viruses (HSV) in genital and oral lesion specimens. The IsoAmp HSV assay uses isothermal helicase-dependent amplification in combination with a disposable, hermetically-sealed, vertical-flow strip identification. The IsoAmp HSV assay has a total test-to-result time of less than 1.5 h by omitting the time-consuming nucleic acid extraction. The diagnostic sensitivity and specificity are comparable to PCR and are superior to culture-based methods. The near instrument-free, rapid and simple characteristics of the IsoAmp HSV assay make it potentially suitable for point-of-care testing.

  9. Fixed type incore measuring device

    International Nuclear Information System (INIS)

    Oda, Naotaka; Ito, Hitoshi; Maeda, Hiroyuki

    1998-01-01

    The present invention concerns a measuring device using gamma thermometers to be used in a BWR type reactor. An input switch is inserted to the vicinity of a detection signal input portion of a signal cable connecting GT with the detection signal input portion of a fixed type incore measuring device, and a loop resistance measuring means is disposed to the input switch on the side of the GT by way of a measurement switch. Upon measuring loop resistance, the GT measuring circuit is switched from the detection signal input portion to the loop resistance measuring means by a switching operation of the input switch and the measurement switch thereby enabling to confirm the value of the loop resistance. In addition, the lowering of the voltage in the loop resistance is compensated to confirm the accurate measurement values to be used thereby enabling to measure GT detection signals accurately. A diagnosing means for diagnosing the state of GT based on the results of the measurement for the loop resistance is disposed, and the results are reported to an operator. (N.H.)

  10. A comparison of 'radon' measurement devices

    International Nuclear Information System (INIS)

    Rolle, R.

    2004-01-01

    For the indoor concentration measurement of Rn decay chain members, instruments ranging from long-term integrating passive devices to far more sensitive active devices with good time resolution are in use. The former are used mainly to screen for potentially high exposure locations, while the latter are useful for assessing the exposure dynamics of encumbered premises, with potential clarification (modelling) for optimal remediation, before, during and after such process. Concentration measurement of any one decay chain member always involves its complete decay chain. The 222 Rn gas concentration can be measured with gas measuring devices or with spectrometric measuring instruments that concentrate the decay products. The latter generally offer far more accurate measurement per time of the 222 Rn concentration, than mere Rn gas measuring devices, and also give the decay product concentrations and thus activity ratios which are related to air exchange. The concentrations of the unattached Rn decay products may be measured simultaneously with inline screen measurement. In premises steady state ventilation conditions are rare. Rapidly changing concentrations can be measured more accurately with the more sensitive concentrating instruments - the inherent instrumental time lag of detected signals from chain decay, relative to time of sampling, should however be corrected where rates of concentration change approximate chain decay constants. Counting of beta-signals in addition to alpha-spectrometry, and quasi-continuous sampling while continuously measuring, enhances the sensitivity, and particularly measurement time lag correction, where concentration ratios are sought for elucidating air exchange. Appropriate software ought to be made available to evaluate the spectrometric data and to link it to suitable compartment ventilation models (automatic adjustment for a dynamic change in alpha-calibration could be incorporated) - this would constitute the modern version of

  11. Method and device for measuring fluid flow

    International Nuclear Information System (INIS)

    Atherton, R.; Marinkovich, P.S.; Spadaro, P.R.; Stout, J.W.

    1976-01-01

    The invention is a fluid flow measuring device for determining the coolant flow at the entrance to a specific nuclear reactor fuel region. The device comprises a plurality of venturis having the upstream inlet and throat pressure of each respectively manifolded together to provide one static pressure signal for each region monitored. The device provides accurate flow measurement with low pressure losses and uniform entrance and discharge flow distribution. 1 claim, 7 figures

  12. ALS insertion device block measurement and inspection

    International Nuclear Information System (INIS)

    Marks, S.; Carrieri, J.; Cook, C.; Hassenzahl, W.V.; Hoyer, E.; Plate, D.

    1991-05-01

    The performance specifications for ALS insertion devices require detailed knowledge and strict control of the Nd-Fe-B permanent magnet blocks incorporated in these devices. This paper describes the measurement and inspection apparatus and the procedures designed to qualify and characterize these blocks. A detailed description of a new, automated Helmholtz coil facility for measurement of the three components of magnetic moment is included. Physical block inspection and magnetic moment measurement procedures are described. Together they provide a basis for qualifying blocks and for specifying placement of blocks within an insertion devices' magnetic structures. 1 ref., 4 figs

  13. In vitro magnetic stimulation: a simple stimulation device to deliver defined low intensity electromagnetic fields

    Directory of Open Access Journals (Sweden)

    Stephanie Grehl

    2016-11-01

    Full Text Available Non-invasive electromagnetic field brain stimulation (NIBS appears to benefit human neurological and psychiatric conditions, although the optimal stimulation parameters and underlying mechanisms remain unclear. Although in vitro studies have begun to elucidate cellular mechanisms, stimulation is delivered by a range of coils (from commercially available human stimulation coils to laboratory-built circuits so that the electromagnetic fields induced within the tissue to produce the reported effects are ill-defined.Here we develop a simple in vitro stimulation device with plug-and-play features that allow delivery of a range of stimulation parameters. We chose to test low intensity repetitive magnetic stimulation (LI-rMS delivered at 3 frequencies to hindbrain explant cultures containing the olivocerebellar pathway. We used computational modelling to define the parameters of a stimulation circuit and coil that deliver a unidirectional homogeneous magnetic field of known intensity and direction, and therefore a predictable electric field, to the target. We built the coil to be compatible with culture requirements: stimulation within an incubator; a flat surface allowing consistent position and magnetic field direction; location outside the culture plate to maintain sterility and no heating or vibration. Measurements at the explant confirmed the induced magnetic field was homogenous and matched the simulation results. To validate our system we investigated biological effects following LI-rMS at 1 Hz, 10 Hz and biomimetic high frequency (BHFS, which we have previously shown induces neural circuit reorganisation. We found that gene expression was modified by LI-rMS in a frequency-related manner. Four hours after a single 10-minute stimulation session, the number of c-fos positive cells increased, indicating that our stimulation activated the tissue. Also, after 14 days of LI-rMS, the expression of genes normally present in the tissue was differentially

  14. Digital Thickness Measurement of a Transparent Plastic Orthodontic Device

    Science.gov (United States)

    Kim, Yoon-Hwan; Rhim, Sung-Han

    2018-05-01

    A transparent orthodontic device is used to move the teeth to the final calibration position to form a proper set of teeth. Because the uniform thickness of the device plays an important role in tooth positioning, the accuracy of the device's thickness profile is important for effective orthodontic treatment. However, due to the complexity of the device's geometry and the transparency of the device's material, measuring the complete thickness profile has been difficult. In the present study, a new optical scanning method to measure the thickness profile of transparent plastic orthodontic devices is proposed and evaluated by using scanning electron microscopy (SEM). The error of the new measurement method is less than ±18 μm. The new method can be used to measure the thickness of non-specific, multi-curved, transparent orthodontic devices.

  15. Dosimetric characterization of an electronic portal imaging device (EPID) and development of a portal dosimetry simple model; Caracterizacion dosimetrica de un dispositivo electronico de imagen portal (EPID) y desarrollo de un modelo simple de dosimetria portal

    Energy Technology Data Exchange (ETDEWEB)

    Ripol ValentIn, O.; GarcIa Romero, A.; Hernandez Vitoria, A.; Jimenez Albericio, J.; Cortes Rodicio, J.; Millan Cebrian, E.; Ruiz Manzano, P.; Canellas Anoz, M.

    2010-07-01

    The use of the Electronic Portal Imaging Devices (EPID) for the quality control of linear accelerators of electrons is increasingly extended in practice. In this work the dosimetric characteristics of an EPID OptiVue{sup TM}1000 ST were studied and a friendly and simple method for the absorbed dose calibration was suggested. This method is based on a simple mathematical model, including: an absorbed dose transformation coefficient and image lag and field shape corrections. Software tools were developed in order to process the information and the results were validated by comparing them with the measured data with ionization chambers. The studied device showed suitable characteristics for its use for EPID dosimetry and the calculated results fitted satisfactorily with the dose planes obtained with the ionization chambers. Keeping in mind the model limitations, we concluded that it is possible to start the use of the EPID for the accelerator quality control and improvements for the current model should be studied, as well as other suitable applications: e.g. the Intensity Modulated Radiation Therapy (IMRT) treatment verification procedures. (Author).

  16. A Simple Device for Lens-to-Sample Distance Adjustment in Laser-Induced Breakdown Spectroscopy (LIBS).

    Science.gov (United States)

    Cortez, Juliana; Farias Filho, Benedito B; Fontes, Laiane M; Pasquini, Celio; Raimundo, Ivo M; Pimentel, Maria Fernanda; de Souza Lins Borba, Flávia

    2017-04-01

    A simple device based on two commercial laser pointers is described to assist in the analysis of samples that present uneven surfaces and/or irregular shapes using laser-induced breakdown spectroscopy (LIBS). The device allows for easy positioning of the sample surface at a reproducible distance from the focusing lens that conveys the laser pulse to generate the micro-plasma in a LIBS system, with reproducibility better than ±0.2 mm. In this way, fluctuations in the fluence (J cm -2 ) are minimized and the LIBS analytical signals can be obtained with a better precision even when samples with irregular surfaces are probed.

  17. Measurement of radon, radon daughters and thoron concentrations by multi-detector devices. No. E/12

    International Nuclear Information System (INIS)

    Somogyi, G.; Varga, Zs.

    1983-01-01

    There is a growing interest in collection of data concerning human exposures to naturally occurring alpha-emitting radionuclides (e.g. in mines, dwellings, building materials, industrial wastes, coal fuel cycle, water supply, soil, plants, etc.). Most of such studies are incomplete for the following reasons: in radon measurements the contribution of thoron is generally neglected, the determination of equilibrium factor is complicated or not possible at all, short- and long-term concentration fluctuations cause difficulties in obtaining representative mean values, the plate-out effect is generally not taken into account. A variety of simple methods were studied that could be used to overcome some of these difficulties by using cups equipped with two or more alpha-sensitive nuclear track detectors. A theoretical foundation of the quantitative measurements with such devices is presented. Experimental data are reported on radon, radon daughters and thoron concentrations measured by multi-detector devices in cave soil gas and in air of Hungarian dwellings. (author)

  18. Simple, economical heat-shock devices for zebrafish housing racks.

    Science.gov (United States)

    Duszynski, Robert J; Topczewski, Jacek; LeClair, Elizabeth E

    2011-12-01

    One reason for the popularity of the zebrafish (Danio rerio) as a model vertebrate is the ability to manipulate gene expression in this organism. A common method is to induce gene expression transiently under control of a heat-shock promoter (e.g., hsp70l). By making simple mechanical adjustments to small aquarium heaters (25-50W), we were able to produce consistent and reliable heat-shock conditions within a conventional zebrafish housing system. Up to two heat-shock intervals per day (>37°C) could be maintained under conditions of continuous flow (5-25 mL/min). Temperature logging every 30 s indicated rapid warm up times, consistent heat-shock lengths, and accurate and precise peak water temperatures (mean±SD=38°C±0.2°C). The biological effects of these heat-shock treatments were confirmed by observing inducible expression of enhanced green fluorescent protein (EGFP) and inhibition of caudal fin regeneration in a transgenic fish line expressing a dominant negative fibroblast growth factor receptor (Tg(hsp70l:dnfgfr1-EGFP)(pd1)). These devices are inexpensive, easily modified, and can be calibrated to accommodate a variety of experimental designs. After setup on a programmable timer, the heaters require no intervention to produce consistent daily heat shocks, and all other standard care protocols can be followed in the fish facility. The simplicity and stability of these devices make them suitable for long-term heat shocks at any stage of the zebrafish lifecycle (>7 days postfertilization), and useful for both laboratory and classroom experiments on transgenic zebrafish.

  19. Temperature measuring device

    Energy Technology Data Exchange (ETDEWEB)

    Lauf, R.J.; Bible, D.W.; Sohns, C.W.

    1999-10-19

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.

  20. A piezo-ring-on-chip microfluidic device for simple and low-cost mass spectrometry interfacing.

    Science.gov (United States)

    Tsao, Chia-Wen; Lei, I-Chao; Chen, Pi-Yu; Yang, Yu-Liang

    2018-02-12

    Mass spectrometry (MS) interfacing technology provides the means for incorporating microfluidic processing with post MS analysis. In this study, we propose a simple piezo-ring-on-chip microfluidic device for the controlled spraying of MALDI-MS targets. This device uses a low-cost, commercially-available ring-shaped piezoelectric acoustic atomizer (piezo-ring) directly integrated into a polydimethylsiloxane microfluidic device to spray the sample onto the MS target substrate. The piezo-ring-on-chip microfluidic device's design, fabrication, and actuation, and its pulsatile pumping effects were evaluated. The spraying performance was examined by depositing organic matrix samples onto the MS target substrate by using both an automatic linear motion motor, and manual deposition. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) was performed to analyze the peptide samples on the MALDI target substrates. Using our technique, model peptides with 10 -6 M concentration can be successfully detected. The results also indicate that the piezo-ring-on-chip approach forms finer matrix crystals and presents better MS signal uniformity with little sample consumption compared to the conventional pipetting method.

  1. A simple electron multiplexer

    International Nuclear Information System (INIS)

    Dobrzynski, L; Akjouj, A; Djafari-Rouhani, B; Al-Wahsh, H; Zielinski, P

    2003-01-01

    We present a simple multiplexing device made of two atomic chains coupled by two other transition metal atoms. We show that this simple atomic device can transfer electrons at a given energy from one wire to the other, leaving all other electron states unaffected. Closed-form relations between the transmission coefficients and the inter-atomic distances are given to optimize the desired directional electron ejection. Such devices can be adsorbed on insulating substrates and characterized by current surface technologies. (letter to the editor)

  2. Microwave Radiometer Linearity Measured by Simple Means

    DEFF Research Database (Denmark)

    Skou, Niels

    2002-01-01

    Modern spaceborne radiometer systems feature an almost perfect on-board calibration, hence the primary calibration task to be carried out before launch is a check of radiometer linearity. This paper describes two ways of measuring linearity of microwave radiometers only requiring relatively simple...

  3. Fabricating Simple Wax Screen-Printing Paper-Based Analytical Devices to Demonstrate the Concept of Limiting Reagent in Acid- Base Reactions

    Science.gov (United States)

    Namwong, Pithakpong; Jarujamrus, Purim; Amatatongchai, Maliwan; Chairam, Sanoe

    2018-01-01

    In this article, a low-cost, simple, and rapid fabrication of paper-based analytical devices (PADs) using a wax screen-printing method is reported here. The acid-base reaction is implemented in the simple PADs to demonstrate to students the chemistry concept of a limiting reagent. When a fixed concentration of base reacts with a gradually…

  4. 21 CFR 864.5950 - Blood volume measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Blood volume measuring device. 864.5950 Section 864.5950 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices...

  5. DEVELOPMENT OF THE LOAD MEASURING DEVICES TO DETERMINE THE RESIDUAL DEFORMATION OF THE ELASTIC SENSING ELEMENT

    Directory of Open Access Journals (Sweden)

    Ivan V. Antonets

    2018-01-01

    Full Text Available The main focus in the design of weighing and batching devices is to create a gravimetric technique, capable of providing not only mass measurement – weighing with the required accuracy and speed, but also automatic control of technological processes and their control and regulation. In this case, the opportunity of two-way communication with a computer when designing the load measuring devices is realized, allowing remote monitoring and solution of logical problems associated with the management process. Modern automatic weighing and batching devices are important parts of comprehensive automation in different branches of industry. Existing developments of electrical, electronic, computing and other branches of instrument engineering techniques allow to implement transformations of the measured quantity with a very high degree of accuracy. However, if the measured quantity in the weighing process is perceived by the elastic sensing element of low quality, then no matter how high the accuracy of further changes is; the characteristics of the elastic element will limit the accuracy of the instrument as a whole. Although the elastic elements are simple mechanical parts, and many types of elastic elements are known and are widely used for many decades, their performance often does not meet the requirements, and hampers the device creation of high accuracy classes. Growing requirements for primary transformer makes actual the problem solution of improving the quality of elastic sensing elements not only in the manufacture but in the design. This led to the appearance of projects aimed at the development of computational and experimental methods that have altered the methodology for the design of force measuring devices.

  6. Device to measure elastic modulus of superconducting windings

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    This device was made to measure elastic modulus of the Po dipole superconducting coils. More elaborated devices, but based on the same concept, were later used to measure the apparent elastic moduli of the LHC superconducting magnet coils. See also 7903547X, 7901386.

  7. Simple apparatus for polarization sensing of analytes

    Science.gov (United States)

    Gryczynski, Zygmunt; Gryczynski, Ignacy; Lakowicz, Joseph R.

    2000-09-01

    We describe a simple device for fluorescence sensing based on an unexpansive light source, a dual photocell and a Watson bridge. The emission is detected from two fluorescent samples, one of which changes intensity in response to the analyte. The emission from these two samples is observed through two orthogonally oriented polarizers and an analyzer polarizer. The latter polarizer is rotated to yield equal intensities from both sides of the dual photocell, as determined by a zero voltage from the Watson bridge. Using this device, we are able to measure fluorescein concentration to an accuracy near 2% at 1 (mu) M fluorescein, and pH values accurate to +/- 0.02 pH units. We also use this approach with a UV hand lamp and a glucose-sensitive protein to measure glucose concentrations near 2 (mu) M to an accuracy of +/- 0.1 (mu) M. This approach requires only simple electronics, which can be battery powered. Additionally, the method is generic, and can be applied with any fluorescent sample that displays a change in intensity. One can imagine this approach being used to develop portable point-of-care clinical devices.

  8. A device for measuring electron beam characteristics

    Directory of Open Access Journals (Sweden)

    M. Andreev

    2017-01-01

    Full Text Available This paper presents a device intended for diagnostics of electron beams and the results obtained with this device. The device comprises a rotating double probe operating in conjunction with an automated probe signal collection and processing system. This provides for measuring and estimating the electron beam characteristics such as radius, current density, power density, convergence angle, and brightness.

  9. Device-Independent Certification of a Nonprojective Qubit Measurement

    Science.gov (United States)

    Gómez, Esteban S.; Gómez, Santiago; González, Pablo; Cañas, Gustavo; Barra, Johanna F.; Delgado, Aldo; Xavier, Guilherme B.; Cabello, Adán; Kleinmann, Matthias; Vértesi, Tamás; Lima, Gustavo

    2016-12-01

    Quantum measurements on a two-level system can have more than two independent outcomes, and in this case, the measurement cannot be projective. Measurements of this general type are essential to an operational approach to quantum theory, but so far, the nonprojective character of a measurement can only be verified experimentally by already assuming a specific quantum model of parts of the experimental setup. Here, we overcome this restriction by using a device-independent approach. In an experiment on pairs of polarization-entangled photonic qubits we violate by more than 8 standard deviations a Bell-like correlation inequality that is valid for all sets of two-outcome measurements in any dimension. We combine this with a device-independent verification that the system is best described by two qubits, which therefore constitutes the first device-independent certification of a nonprojective quantum measurement.

  10. Accuracy of portable devices in measuring peak cough flow

    International Nuclear Information System (INIS)

    Kulnik, Stefan Tino; Kalra, Lalit; MacBean, Victoria; Birring, Surinder Singh; Moxham, John; Rafferty, Gerrard Francis

    2015-01-01

    Peak cough flow (PCF) measurements can be used as indicators of cough effectiveness. Portable peak flow meters and spirometers have been used to measure PCF, but little is known about their accuracy compared to pneumotachograph systems. The aim of this study was to compare the accuracy of four portable devices (Mini–Wright and Assess peak flow meters, SpiroUSB and Microlab spirometers) in measuring PCF with a calibrated laboratory based pneumotachograph system. Twenty healthy volunteers (mean (SD) age 45 (16) years) coughed through a pneumotachograph connected in series with each portable device in turn, and the differences in PCF readings were analysed. In addition, mechanically generated flow waves of constant peak flow were delivered through each device both independently and when connected in series with the pneumotachograph. Agreement between PCF readings obtained with the pneumotachograph and the portable devices was poor. Peak flow readings were on average lower by approximately 50 L min −1 when measured using the portable devices; 95% limits of agreement spanned approximately 150 L min −1 . The findings highlight the potential for inaccuracy when using portable devices for the measurement of PCF. Depending on the measurement instrument used, absolute values of PCF reported in the literature may not be directly comparable. (paper)

  11. Device independent quantum key distribution secure against coherent attacks with memoryless measurement devices

    International Nuclear Information System (INIS)

    McKague, Matthew

    2009-01-01

    Device independent quantum key distribution (QKD) aims to provide a higher degree of security than traditional QKD schemes by reducing the number of assumptions that need to be made about the physical devices used. The previous proof of security by Pironio et al (2009 New J. Phys. 11 045021) applies only to collective attacks where the state is identical and independent and the measurement devices operate identically for each trial in the protocol. We extend this result to a more general class of attacks where the state is arbitrary and the measurement devices have no memory. We accomplish this by a reduction of arbitrary adversary strategies to qubit strategies and a proof of security for qubit strategies based on the previous proof by Pironio et al and techniques adapted from Renner.

  12. Measurement-Device Independency Analysis of Continuous-Variable Quantum Digital Signature

    Directory of Open Access Journals (Sweden)

    Tao Shang

    2018-04-01

    Full Text Available With the practical implementation of continuous-variable quantum cryptographic protocols, security problems resulting from measurement-device loopholes are being given increasing attention. At present, research on measurement-device independency analysis is limited in quantum key distribution protocols, while there exist different security problems for different protocols. Considering the importance of quantum digital signature in quantum cryptography, in this paper, we attempt to analyze the measurement-device independency of continuous-variable quantum digital signature, especially continuous-variable quantum homomorphic signature. Firstly, we calculate the upper bound of the error rate of a protocol. If it is negligible on condition that all measurement devices are untrusted, the protocol is deemed to be measurement-device-independent. Then, we simplify the calculation by using the characteristics of continuous variables and prove the measurement-device independency of the protocol according to the calculation result. In addition, the proposed analysis method can be extended to other quantum cryptographic protocols besides continuous-variable quantum homomorphic signature.

  13. Temperature measurement device

    International Nuclear Information System (INIS)

    Fournier, Christian; Lions, Noel.

    1975-01-01

    The present invention relates to a temperature measuring system that can be applied in particular to monitoring the temperature of the cooling liquid metal of the outlet of the core assemblies of a fast reactor. Said device combines a long hollow metallic pole, at least partially dipped into the liquid metal and constituting a first thermocouple junction between said pole, and two metallic conductors of different nature, joined at one of their ends to constitute the second thermocouple junction. Said conductors suitably insulated are arranged inside a sheath. Said sheath made of the same metals as the pole extends inside the latter and is connected with the pole through a soldered joint. Said reliable system permits an instantaneous measurement of a quantity representing the variations in the recorded temperature and a measurement of the mean surrounding temperature that can be direcly used as a reference for calibrating the first one [fr

  14. Radon Measurement Proficiency (RMP) Program methods and devices

    International Nuclear Information System (INIS)

    Harrison, J.; Hoornbeek, J.; Jalbert, P.; Sensintaffar, E.; Hopper, R.

    1991-01-01

    The US EPA developed the voluntary Radon Measurement Proficiency Program in 1986 in response to a Federal and State need for measurement services firms to demonstrate their proficiency with radon measurement methods and devices. Since that time, the program has set basic standards for the radon measurement industry. The program has grown dramatically since its inception. In 1986, fewer than 50 companies participated in the program. By 1989, more than 5,000 companies were participating. Participants represent firms with an analytical capability as well as firms that rely upon another firm for analysis service. Since the beginning of the RMP Program, the Agency has learned a great deal about radon measurement methods and devices. This paper reviews the measurement devices used in the program and what the EPA has learned about them since the program's inception. Performance data from the RMP Program are used to highlight relevant findings

  15. Device for the alternative option of temperature measurement

    Science.gov (United States)

    Jargus, Jan; Nedoma, Jan; Fajkus, Marcel; Novak, Martin; Cubik, Jakub; Cvejn, Daniel; Vasinek, Vladimir

    2017-10-01

    Polydimethylsiloxane (PDMS) has good optical properties, and its composition offers the possibility of use in many applications (industry, security device, medicine applications and etc.). We focused on the alternative option of temperature measurement in this article. Our approach is based on measuring changes of chromaticity correlated temperature corresponding to changes in temperature. Described device uses an optical fiber with a defined layer of PDMS and luminophore and we assume that it can find use also in the field of security. The article describes the process of making the prototype of the device and its verification based on laboratory results. The measured temperature depends mainly on the type of optical fiber and the measured temperature range is determined by the thermal resistance of used optical fiber. Using a calibration measurement can determine the value of temperature with an accuracy of +/- 2,5 %.

  16. Experimental Measurement-Device-Independent Entanglement Detection

    Science.gov (United States)

    Nawareg, Mohamed; Muhammad, Sadiq; Amselem, Elias; Bourennane, Mohamed

    2015-02-01

    Entanglement is one of the most puzzling features of quantum theory and of great importance for the new field of quantum information. The determination whether a given state is entangled or not is one of the most challenging open problems of the field. Here we report on the experimental demonstration of measurement-device-independent (MDI) entanglement detection using witness method for general two qubits photon polarization systems. In the MDI settings, there is no requirement to assume perfect implementations or neither to trust the measurement devices. This experimental demonstration can be generalized for the investigation of properties of quantum systems and for the realization of cryptography and communication protocols.

  17. Radiation flux measuring device

    International Nuclear Information System (INIS)

    Corte, E.; Maitra, P.

    1977-01-01

    A radiation flux measuring device is described which employs a differential pair of transistors, the output of which is maintained constant, connected to a radiation detector. Means connected to the differential pair produce a signal representing the log of the a-c component of the radiation detector, thereby providing a signal representing the true root mean square logarithmic output. 3 claims, 2 figures

  18. A power measuring device

    International Nuclear Information System (INIS)

    As, R. van.

    1985-01-01

    As a part of the klystron test facility of the Dutch NIKHEF-K accelerator, a sensitive power measuring device has been built. The high-frequency power of a klystron is stored in a water-cooled dummy load. Using a microcomputer, the increase of the water temperature and the water flow rate are transformed to a digital indication of the klystron power. (Auth.)

  19. AN ADVANCED CALIBRATION PROCEDURE FOR COMPLEX IMPEDANCE SPECTRUM MEASUREMENTS OF ADVANCED ENERGY STORAGE DEVICES

    Energy Technology Data Exchange (ETDEWEB)

    William H. Morrison; Jon P. Christophersen; Patrick Bald; John L. Morrison

    2012-06-01

    With the increasing demand for electric and hybrid electric vehicles and the explosion in popularity of mobile and portable electronic devices such as laptops, cell phones, e-readers, tablet computers and the like, reliance on portable energy storage devices such as batteries has likewise increased. The concern for the availability of critical systems in turn drives the availability of battery systems and thus the need for accurate battery health monitoring has become paramount. Over the past decade the Idaho National Laboratory (INL), Montana Tech of the University of Montana (Tech), and Qualtech Systems, Inc. (QSI) have been developing the Smart Battery Status Monitor (SBSM), an integrated battery management system designed to monitor battery health, performance and degradation and use this knowledge for effective battery management and increased battery life. Key to the success of the SBSM is an in-situ impedance measurement system called the Impedance Measurement Box (IMB). One of the challenges encountered has been development of an accurate, simple, robust calibration process. This paper discusses the successful realization of this process.

  20. A Simple Method to Measure the Thermal contraction Percentage of a Solid Between Room and Liquid Nitrogen Temperatures

    International Nuclear Information System (INIS)

    Grau Carles, A.; Grau Malonda, A.

    2000-01-01

    We described how to build a simple device for measuring, with a reasonable good accuracy, the thermal contraction of a flat sample between room and liquid nitrogen temperatures. The contraction percentage of the sample is determined by the dimensional comparison of two images taken through the bottom of a transparent quartz tray. Instead of a photo or video camera, a high-resolution flatbed scanner is utilized to avoid the correction of perspectives. The so-called Grueneisen approximation are applied to evaluate the contraction percentages for intermediate temperatures. (Author) 28 refs

  1. Occlusion of the Neonatal Patent Ductus Arteriosus with a Simple Retrievable Device: A Feasibility Study

    International Nuclear Information System (INIS)

    Neuss, Malte B.; Coe, James Y.; Tio, Fermin; Le, Trong-Phi; Grabitz, Ralph; Redel, Dirk A.

    1996-01-01

    Purpose: To examine the feasibility of transvenous placement of a new memory-shaped, small, retrievable coil that has a smaller-caliber delivery system than currently available devices, for closure of the patent ductus arteriosus (PDA). Methods: Through 4 or 5 Fr vascular sheaths and 4 or 5 Fr end-hold catheters, the coils were delivered and placed in piglets (n= 10) with PDA. The coils were made from 0.018'' (0.46 mm) or 0.028'' (0.71 mm) stainless steel guidewire. Mounted for delivery, the new device has the appearance of a conventional guidewire. This neonatal PDA model was created without major surgery or drugs by stenting the ductus arteriosus. Results: The memory-shaped coils were easily delivered. Coils not optimally placed were retrieved and repositioned. Occlusion of the ductus arteriosus as early as a half-hour after delivery was shown angiographically and confirmed by histopathology. Conclusion: This new, small-caliber, simple device was found to be effective for closure of the PDA in this animal model. Longer-term observations are needed

  2. Occlusion of the Neonatal Patent Ductus Arteriosus with a Simple Retrievable Device: A Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Neuss, Malte B [Department of Cardiology, Children' s Hospital, University of Bonn, Adenauerallee 119, D-5300, Bonn 1 (Germany); Coe, James Y [Division of Pediatric Cardiology and Cardiovascular Research Group, University of Alberta, Edmonton, Alberta (Canada); Tio, Fermin [Department of Pathology, University of Texas Health Sciences Center at San Antonio, 7703 Floyd Curl Drive, San Antonio, TX 78284-7750 (United States); Le, Trong-Phi [Department of Cardiology, Children' s Hospital, University of Bonn, Adenauerallee 119, D-5300, Bonn 1 (Germany); Grabitz, Ralph [Division of Pediatric Cardiology and Cardiovascular Research Group, University of Alberta, Edmonton, Alberta (Canada); Redel, Dirk A [Department of Cardiology, Children' s Hospital, University of Bonn, Adenauerallee 119, D-5300, Bonn 1 (Germany)

    1996-05-15

    Purpose: To examine the feasibility of transvenous placement of a new memory-shaped, small, retrievable coil that has a smaller-caliber delivery system than currently available devices, for closure of the patent ductus arteriosus (PDA). Methods: Through 4 or 5 Fr vascular sheaths and 4 or 5 Fr end-hold catheters, the coils were delivered and placed in piglets (n= 10) with PDA. The coils were made from 0.018'' (0.46 mm) or 0.028'' (0.71 mm) stainless steel guidewire. Mounted for delivery, the new device has the appearance of a conventional guidewire. This neonatal PDA model was created without major surgery or drugs by stenting the ductus arteriosus. Results: The memory-shaped coils were easily delivered. Coils not optimally placed were retrieved and repositioned. Occlusion of the ductus arteriosus as early as a half-hour after delivery was shown angiographically and confirmed by histopathology. Conclusion: This new, small-caliber, simple device was found to be effective for closure of the PDA in this animal model. Longer-term observations are needed.

  3. A simple and cost-effective method for fabrication of integrated electronic-microfluidic devices using a laser-patterned PDMS layer

    KAUST Repository

    Li, Ming

    2011-12-03

    We report a simple and cost-effective method for fabricating integrated electronic-microfluidic devices with multilayer configurations. A CO 2 laser plotter was employed to directly write patterns on a transferred polydimethylsiloxane (PDMS) layer, which served as both a bonding and a working layer. The integration of electronics in microfluidic devices was achieved by an alignment bonding of top and bottom electrode-patterned substrates fabricated with conventional lithography, sputtering and lift-off techniques. Processes of the developed fabrication method were illustrated. Major issues associated with this method as PDMS surface treatment and characterization, thickness-control of the transferred PDMS layer, and laser parameters optimization were discussed, along with the examination and testing of bonding with two representative materials (glass and silicon). The capability of this method was further demonstrated by fabricating a microfluidic chip with sputter-coated electrodes on the top and bottom substrates. The device functioning as a microparticle focusing and trapping chip was experimentally verified. It is confirmed that the proposed method has many advantages, including simple and fast fabrication process, low cost, easy integration of electronics, strong bonding strength, chemical and biological compatibility, etc. © Springer-Verlag 2011.

  4. A Practical Device for Measuring the Luminance Distribution

    Directory of Open Access Journals (Sweden)

    Thijs Kruisselbrink

    2017-06-01

    Full Text Available Various applications in building lighting such as automated daylight systems, dynamic lighting control systems, lighting simulations, and glare analyzes can be optimized using information on the actual luminance distributions of the surroundings. Currently, commercially available luminance distribution measurement devices are often not suitable for these kind of applications or simply too expensive for broad application. This paper describes the development of a practical and autonomous luminance distribution measurement device based on a credit card-sized single-board computer and a camera system. The luminance distribution was determined by capturing High Dynamic Range images and translating the RGB information to the CIE XYZ color space. The High Dynamic Range technology was essential to accurately capture the data needed to calculate the luminance distribution because it allows to capture luminance ranges occurring in real scenarios. The measurement results were represented in accordance with established methods in the field of daylighting. Measurements showed that the accuracy of the luminance distribution measurement device ranged from 5% to 20% (worst case which was deemed acceptable for practical measurements and broad applications in the building realm.

  5. Simple artificial training device for respiratory muscle strength and lung volumes in healthy young male and female subjects: A pilot study.

    Science.gov (United States)

    Leelarungrayub, Jirakrit; Pinkaew, Decha; Yankai, Araya; Chautrakoon, Busaba; Kuntain, Rungtiwa

    2017-10-01

    The aim of this study was to evaluate the efficiency of a simple artificial device for respiratory muscle strength training and lung volumes using either combined or non-combined exercise with elastic bands in healthy young participants. Forty healthy young participants (20 male and 20 female) aged 19-24 years old were randomized into two main experiments with four sub-groups; (1) artificial device (n = 10) & standard device (n = 10) training, and (2) artificial device training combined with elastic band (EB) exercise (n = 10) & standard device training combined with EB (n = 10) exercise. Respiratory muscle strength with maximal peak inspiratory pressure (PImax), and lung volumes; tidal volume (TV), inspiratory reserve volume (IRV), expiratory reserve volume (ERV) and vital capacity (VC) were evaluated before and after training once daily for 3 weeks. Moreover, the peak dyspnea score and vital sign parameters were compared between the experimental groups after final training. All parameters had no statistical differences (p > 0.5) between the training devices alone and those combined with EB exercise prior to any experiments. Results from the first experiment showed that training with an artificial device increased all parameters (PImax, VC, IRV, ERV) significantly (p artificial device training combined with EB exercise showed a significant increase in all parameters, except for TV, and they were the same as the increased results in training with the standard device combined with EB exercise. There was no significant difference of data between these groups after the training period. Finally, the results of peak dyspnea score and all vital sign parameters from using the artificial device, with or without EB exercise, showed no statistical difference when compared to use of the standard device. This study proposed that a simple artificial device can be used to train the respiratory muscle with or without elastic band exercise in healthy young subjects

  6. Device for measuring atmospheric radon activity

    International Nuclear Information System (INIS)

    Deml, F.; Jansky, Z.; Smejkal, Z.

    1989-01-01

    The device consists of a lightproof case pivoted on a stand. Minimally two chambers are provided in the case for holding glass scintillation chambers, each with an opening in its bottom. The centers of the openings lie on a common circle with its center in the center of rotation of the case. An opening for the passage of light is provided in the stand. The opening also is on the common circle of the centres of the openings. A photomultiplier is placed below the opening. Measurement always proceeds with one scintillation chamber only. Thus, replacement of scintillation chambers can take place simultaneously with measurement and rapid and continuous measurement can be secured. Case rotation can be controlled automatically. The device can be used not only in monitoring air pollution but also in monitoring solid materials, aquifers, mine corridors, natural materials, etc. (J.B.). 1 fig

  7. Nuclear-burst strength detecting and measuring device

    International Nuclear Information System (INIS)

    Balut, J.A.L.G.; Lemaire, P.E.G.K.; Loisy, C.M.

    1976-01-01

    A continuous-operation automatic device is described for detection and accurate measurement of the strength of a burst generating an emission from luminous or infrared sources. This device characterizes and analyzes the maxima and minima of a ''thermal flux/time'' curve. The device comprises a master time element and an assembly of photoelectric detectors, an electronic processing system coupled to the detectors, and a mechanical system securing the rigidity and positioning of the photoelectric detector assembly with respect to an octahedral prism based on a horizontal plane

  8. Measuring ionizing radiation with a mobile device

    Science.gov (United States)

    Michelsburg, Matthias; Fehrenbach, Thomas; Puente León, Fernando

    2012-02-01

    In cases of nuclear disasters it is desirable to know one's personal exposure to radioactivity and the related health risk. Usually, Geiger-Mueller tubes are used to assess the situation. Equipping everyone with such a device in a short period of time is very expensive. We propose a method to detect ionizing radiation using the integrated camera of a mobile consumer device, e.g., a cell phone. In emergency cases, millions of existing mobile devices could then be used to monitor the exposure of its owners. In combination with internet access and GPS, measured data can be collected by a central server to get an overview of the situation. During a measurement, the CMOS sensor of a mobile device is shielded from surrounding light by an attachment in front of the lens or an internal shutter. The high-energy radiation produces free electrons on the sensor chip resulting in an image signal. By image analysis by means of the mobile device, signal components due to incident ionizing radiation are separated from the sensor noise. With radioactive sources present significant increases in detected pixels can be seen. Furthermore, the cell phone application can make a preliminary estimate on the collected dose of an individual and the associated health risks.

  9. Temperature measurement with industrial color camera devices

    Science.gov (United States)

    Schmidradler, Dieter J.; Berndorfer, Thomas; van Dyck, Walter; Pretschuh, Juergen

    1999-05-01

    This paper discusses color camera based temperature measurement. Usually, visual imaging and infrared image sensing are treated as two separate disciplines. We will show, that a well selected color camera device might be a cheaper, more robust and more sophisticated solution for optical temperature measurement in several cases. Herein, only implementation fragments and important restrictions for the sensing element will be discussed. Our aim is to draw the readers attention to the use of visual image sensors for measuring thermal radiation and temperature and to give reasons for the need of improved technologies for infrared camera devices. With AVL-List, our partner of industry, we successfully used the proposed sensor to perform temperature measurement for flames inside the combustion chamber of diesel engines which finally led to the presented insights.

  10. Using Teacher-Made Measurement Devices.

    Science.gov (United States)

    Mehrens, William A.; Lehmann, Irvin J.

    1987-01-01

    Classroom measurement devices, when tailored to fit a teacher's particular instructional objectives, are essential for optimal teaching and learning. Teachers use test data to assess students' progress but often fail to analyze tests for validity. This article shows how locally and correctly developed assessment tools may serve a variety of…

  11. Simple and portable low frequency lock-in amplifier designed for photoacoustic measurements and its application to thermal effusivity determination in liquids

    Science.gov (United States)

    Ortega-Robles, Emmanuel; Cruz-Orea, Alfredo; Elías-Viñas, David

    2018-03-01

    The lock-in amplifier is a very useful instrument for observing very small signals under adverse signal-to-noise conditions. In this work, we describe a simple and portable lock-in amplifier designed to be used in photoacoustic measurements. The device was used to measure the thermal effusivity of eight different liquid samples (distilled water, glycerol, acetone, ethanol, 2-propanol, chloroform, hexane, and methanol), as well as the effusivity of acetone in aqueous solution at distinct concentrations, giving good results. The instrument has a bandwidth of 10 Hz-10 kHz and a sensitivity of 1 μV.

  12. Scattering measurements in Tokamak type devices

    International Nuclear Information System (INIS)

    Matoba, Tohru

    1975-03-01

    Theories, experiments and proposals for light scattering in Tokamak type devices are reviewed. Thomson scattering, measuring method of the current density distribution by scattering and resonance fluorescence are summarily described. These methods may be useful for diagnosis of the fusion plasmas. The report may help planning of the measuring apparatus for the fusion plasmas in future. (auth.)

  13. Measurement Devices and the Psychophysiology of Consumer Behaviour

    DEFF Research Database (Denmark)

    Schwarzkopf, Stefan

    2015-01-01

    of the type of subjectivity that underlies consumer behaviour. I argue instead that a posthuman view of the relationship between brain, mind and behaviour underpinned neurophysiological research into consumers from its very beginning in the late nineteenth century. By tracing the biopolitical potentialities...... of neuromarketing back to the Fin-de-Siècle neurophysiological laboratory, I show that consumers' bodies and later on their brains became reconfigured as part of a dispositif made up of laboratory-based artefacts (measurement devices) and new ways of seeing the human brain and human behaviour. This dispositif......From the 1890s, psychophysiological measurement devices have played an important, but as yet under-theorized role in marketing and consumer research. Because of the recent advances made in neuromarketing, it is often assumed that these measurement devices ushered in a radically new understanding...

  14. Dose rate measuring device and dose rate measuring method using the same

    International Nuclear Information System (INIS)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-01-01

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  15. Dose rate measuring device and dose rate measuring method using the same

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Megumu; Matsushita, Takashi; Hanazawa, Sadao; Konno, Takahiro; Chiba, Yoshinori; Yumitate, Tadahiro

    1998-11-13

    The device of the present invention comprises a scintillation fiber scope having a shape elongated in the direction of the height of a pressure vessel and emitting light by incident of radiation to detect radiation, a radioactivity measuring device for measuring a dose rate based on the detection of the fiber scope and a reel means for dispensing and taking up the fiber scope, and it constituted such that the dose rate of the pressure vessel and that of a shroud are determined independently. Then, when the taken out shroud is contained in an container, excessive shielding is not necessary, in addition, this device can reliably be inserted to or withdrawn from complicated places between the pressure vessel and the shroud, and further, the dose rate of the pressure vessel and that of the shroud can be measured approximately accurately even when the thickness of them is different greatly. (N.H.)

  16. [Mobile Health: IEEE Standard for Wearable Cuffless Blood Pressure Measuring Devices].

    Science.gov (United States)

    Zhou, Xia; Wu, Wenli; Bao, Shudi

    2015-07-01

    IEEE Std 1708-2014 breaks through the traditional standards of cuff based blood pressure measuring devices and establishes a normative definition of wearable cuffless blood pressure measuring devices and the objective performance evaluation of this kind of devices. This study firstly introduces the background of the new standard. Then, the standard details will be described, and the impact of cuffless blood pressure measuring devices with the new standard on manufacturers and end users will be addressed.

  17. Classification of methods for measuring current-voltage characteristics of semiconductor devices

    Directory of Open Access Journals (Sweden)

    Iermolenko Ia. O.

    2014-06-01

    Full Text Available It is shown that computer systems for measuring current-voltage characteristics are very important for semiconductor devices production. The main criteria of efficiency of such systems are defined. It is shown that efficiency of such systems significantly depends on the methods for measuring current-voltage characteristics of semiconductor devices. The aim of this work is to analyze existing methods for measuring current-voltage characteristics of semiconductor devices and to create the classification of these methods in order to specify the most effective solutions in terms of defined criteria. To achieve this aim, the most common classifications of methods for measuring current-voltage characteristics of semiconductor devices and their main disadvantages are considered. Automated and manual, continuous, pulse, mixed, isothermal and isodynamic methods for measuring current-voltage characteristics are analyzed. As a result of the analysis and generalization of existing methods the next classification criteria are defined: the level of automation, the form of measurement signals, the condition of semiconductor device during the measurements, and the use of mathematical processing of the measurement results. With the use of these criteria the classification scheme of methods for measuring current-voltage characteristics of semiconductor devices is composed and the most effective methods are specified.

  18. Pressure and Relative Humidity Measurement Devices for Mars 2020 Rover

    Science.gov (United States)

    Hieta, M.; Genzer, M.; Nikkanen, T.; Haukka, H.; Harri, A.-M.; Polkko, J.; Rodriguez-Manfredi, J. A.

    2017-09-01

    One of the scientific payloads onboard the NASA Mars 2020 rover mission is Mars Environmental Dynamic Analyzer (MEDA): a set of environmental sensors for Mars surface weather measurements. Finnish Meteorological Institute (FMI) provides a pressure measurement device (MEDA PS) and a relative humidity measurement device (MEDA HS) for MEDA.

  19. Pressure measurements in magnetic-fusion devices

    International Nuclear Information System (INIS)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration

  20. Pressure measurements in magnetic-fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Dylla, H.F.

    1981-11-01

    Accurate pressure measurements are important in magnetic fusion devices for: (1) plasma diagnostic measurements of particle balance and ion temperature; (2) discharge cleaning optimization; (3) vacuum system performance; and (4) tritium accountability. This paper reviews the application, required accuracy, and suitable instrumentation for these measurements. Demonstrated uses of ionization-type and capacitance-diaphragm gauges for various pressure and gas-flow measurements in tokamaks are presented, with specific reference to the effects of magnetic fields on gauge performance and the problems associated with gauge calibration.

  1. A thermal technique for local ultrasound intensity measurement: part 2. Application to exposimetry on a medical diagnostic device

    International Nuclear Information System (INIS)

    Wilkens, V

    2010-01-01

    Acoustic output measurements on medical ultrasound equipment are usually performed using radiation force balances to determine the output power and using hydrophones to determine pressure and intensity parameters. The local temporal-average ultrasound intensity can be measured alternatively by thermal sensors. The technique was described and prototype sensors were characterized in a preceding paper. Here, the application of such a thermal intensity sensor to the output beam characterization of a typical medical diagnostic device is described. Two transducers, a 7.5 MHz linear array and a 3.5 MHz convex array were investigated in different operating modes. For comparison, hydrophone measurements were also performed. If the spatial averaging effect is taken into account, good agreement is found between both measurement methods. The maximum deviations of the spatial-peak temporal-average intensities I SPTA obtained with the thermal sensor from the corresponding hydrophone-based results were below 12%. The simple thermal technique offers advantages for intensity measurements especially in the case of scanning and combined modes of the diagnostic device, where the synchronization between hydrophone measurements and the complex pulse emission pattern can be difficult

  2. Modern devices the simple physics of sophisticated technology

    CERN Document Server

    Joseph, Charles L

    2016-01-01

    This book discusses the principles of physics through applications of state-of-the-art technologies and advanced instruments. The authors use diagrams, sketches, and graphs coupled with equations and mathematical analysis to enhance the reader's understanding of modern devices. Readers will learn to identify common underlying physical principles that govern several types of devices, while gaining an understanding of the performance trade-off imposed by the physical limitations of various processing methods. The topics discussed in the book assume readers have taken an introductory physics course, college algebra, and have a basic understanding of calculus. * Describes the basic physics behind a large number of devices encountered in everyday life, from the air conditioner to Blu-ray discs * Covers state-of-the-art devices such as spectrographs, photoelectric image sensors, spacecraft systems, astronomical and planetary observatories, biomedical imaging instruments, particle accelerators, and jet engines * Inc...

  3. Nonlinear electrical properties of Si three-terminal junction devices

    DEFF Research Database (Denmark)

    Fantao, Meng; Jie, Sun; Graczyk, Mariusz

    2010-01-01

    This letter reports on the realization and characterization of silicon three-terminal junction devices made in a silicon-on-insulator wafer. Room temperature electrical measurements show that the fabricated devices exhibit pronounced nonlinear electrical properties inherent to ballistic electron...... transport in a three-terminal ballistic junction (TBJ) device. The results show that room temperature functional TBJ devices can be realized in a semiconductor material other than high-mobility III-V semiconductor heterostructures and provide a simple design principle for compact silicon devices...

  4. Device for measuring fission product density

    International Nuclear Information System (INIS)

    Kaneda, Mitsunori.

    1980-01-01

    Purpose: To determine the fission product density of xenon or the like and enable measurement of real time of fission product density in a reactor by calculating the disintegration and annihilation of the fission product on the basis of neutron detected output. Constitution: The neutron flux in a reactor is detected by a detector, and applied to first and second density calculators. Second fission product density signal of xenon or the like outputted from first device is again inputted to the device to form an annihilation signal due to disintegration to determine the present density of the second fission product of xenon or the like corresponding to the decrease of the neutron due to the poison of xeron or the like. Similarly, second device determines the first fission product density of iodine or the like. (Sekiya, K.)

  5. Simple System to Measure the Earth's Magnetic Field

    Science.gov (United States)

    Akoglu, R.; Halilsoy, M.; Mazharimousavi, S. Habib

    2010-01-01

    Our aim in this proposal is to use Faraday's law of induction as a simple lecture demonstration to measure the Earths magnetic field (B). This will also enable the students to learn about how electric power is generated from rotational motion. Obviously the idea is not original, yet it may be attractive in the sense that no sophisticated devices…

  6. Beam diagnostics using an emittance measurement device

    International Nuclear Information System (INIS)

    Sarstedt, M.; Becker, R.; Klein, H.; Maaser, A.; Mueller, J.; Thomae, R.; Weber, M.

    1995-01-01

    For beam diagnostics aside from Faraday cups for current measurements and analysing magnets for the determination of beam composition and energy the most important tool is an emittance measurement device. With such a system the distribution of the beam particles in phase-space can be determined. This yields information not only on the position of the particles but also on their angle with respect to the beam axis. There are different kinds of emittance measurement devices using either circular holes or slits for separation of part of the beam. The second method (slit-slit measurement), though important for the determination of the rms-emittance, has the disadvantage of integrating over the y- and y'-coordinate (measurement in xx'-plane assumed). This leads to different emittance diagrams than point-point measurements, since in xx'-plane for each two corresponding points of rr'-plane there exists a connecting line. With regard to beam aberrations this makes xx'-emittances harder to interpret. In this paper the two kinds of emittance diagrams are discussed. Additionally the influence of the slit height on the xx'-emittance is considered. The analytical results are compared to experimental measurements in rr'-, rx'- and xx'-phase-space. (orig.)

  7. The Reliability of a Novel Mobile 3-dimensional Wound Measurement Device.

    Science.gov (United States)

    Anghel, Ersilia L; Kumar, Anagha; Bigham, Thomas E; Maselli, Kathryn M; Steinberg, John S; Evans, Karen K; Kim, Paul J; Attinger, Christopher E

    2016-11-01

    Objective assessment of wound dimensions is essential for tracking progression and determining treatment effectiveness. A reliability study was designed to establish intrarater and interrater reliability of a novel mobile 3-dimensional wound measurement (3DWM) device. Forty-five wounds were assessed by 2 raters using a 3DWM device to obtain length, width, area, depth, and volume measurements. Wounds were also measured manually, using a disposable ruler and digital planimetry. The intraclass correlation coefficient (ICC) was used to establish intrarater and interrater reliability. High levels of intrarater and interrater agreement were observed for area, length, and width; ICC = 0.998, 0.977, 0.955 and 0.999, 0.997, 0.995, respectively. Moderate levels of intrarater (ICC = 0.888) and interrater (ICC = 0.696) agreement were observed for volume. Lastly, depth yielded an intrarater ICC of 0.360 and an interrater ICC of 0.649. Measures from the 3DWM device were highly correlated with those obtained from scaled photography for length, width, and area (ρ = 0.997, 0.988, 0.997, P device yielded correlations of ρ = 0.990, 0.987, 0.996 with P device was found to be highly reliable for measuring wound areas for a range of wound sizes and types as compared to manual measurement and digital planimetry. The depth and therefore volume measurement using the 3DWM device was found to have a lower ICC, but volume ICC alone was moderate. Overall, this device offers a mobile option for objective wound measurement in the clinical setting.

  8. Accuracy and reproducibility of simple cross-sectional linear and area measurements of brain structures and their comparison with volume measurements

    International Nuclear Information System (INIS)

    Whalley, H.C.; Wardlaw, J.M.

    2001-01-01

    Volumetric measurement of brain structure on brain images is regarded as a gold standard, yet is very time consuming. We wondered whether simple linear and area measurements might be as accurate and reproducible. Two observers independently measured the cross-sectional area of the corpus callosum, lentiform and caudate nuclei, thalamus, amygdalas, hippocampi, lateral and third ventricles, and the width of the sylvian and frontal interhemispheric fissures and brain stem on brain MRI of 55 patients using a program written in-house; one observer also measured the volumes of the basal ganglia, amygdalo-hippocampal complex and ventricular system using Analyze, and performed qualitative assessment of four regions (lateral and third ventricles, cortex, and medial temporal lobe) using the Lieberman score. All measures were performed blinded to all other information. Test objects of known size were also imaged with MRI and measured by the two observers using the in-house program. The true sizes of the test objects were measured using engineering calipers by two observers blind to the MRI results. Differences between the two observers using the same measurement method, and one observer using different methods, were calculated. The simple linear and cross-sectional area measurements were rapid (20 min versus 5 h for volumetric); were highly accurate for test-object measurement versus true size; had excellent intraobserver reliability; and, for most brain structures, the simple measures correlated highly significantly with volumetric measures. The simple measures were in general highly reproducible, the difference (as a percentage of the area or width of a region) between the two raters being around 10 %, range 0.1 %- 14.1 %, (similar to inter-rater variability in previous studies of volume measurements). The simple linear and area measures are reproducible and correlate well with the measured volumes, and there is a considerable time saving with the former. In circumstances

  9. Device of measuring hydrogen in U-H-Zr fuel pellet

    International Nuclear Information System (INIS)

    Li Ming; Guo Qiaoru; Xu Xiuqing

    1992-01-01

    A device used for the determination of hydrogen content in U-H-Zr fuel pellet and its precision determination are introduced. The influence of different flow of carry gas, extracting temperature and collecting time on the determination of hydrogen content is researched separately. While the flow of carry gas is 85-100 mL/min and extracting temperature increasing to 1550 deg C, the best collecting time may be reduced to 18 min from 30 min, the determination of zirconium hydrogenate reference standard sample shows that the precision of six time determination is smaller than ±2%, determination error is 2%. The rate of recovery of hydrogen is 99.3%. The test shows that the device and its determination method are stable and operation is simple

  10. Simple turbulence measurements with azopolymer thin films.

    Science.gov (United States)

    Barillé, Regis; Pérez, Darío G; Morille, Yohann; Zielińska, Sonia; Ortyl, Ewelina

    2013-04-01

    A simple method to measure the influence on the laser beam propagation by a turbid medium is proposed. This measurement is based on the inscription of a surface relief grating (SRG) on an azopolymer thin film. The grating obtained with a single laser beam after propagation into a turbulent medium is perturbed and directly analyzed by a CCD camera through its diffraction pattern. Later, by scanning the surface pattern with an atomic force microscope, the inscribed SRG is analyzed with the Radon transform. This method has the advantage of using a single beam to remotely inscribe a grating detecting perturbations during the beam path. A method to evaluate the refractive index constant structure is developed.

  11. Measurement of Visual Reaction Times Using Hand-held Mobile Devices

    Science.gov (United States)

    Mulligan, Jeffrey B.; Arsintescu, Lucia; Flynn-Evans, Erin

    2015-01-01

    Modern mobile devices provide a convenient platform for collecting research data in the field. But,because the working of these devices is often cloaked behind multiple layers of proprietary system software, it can bedifficult to assess the accuracy of the data they produce, particularly in the case of timing. We have been collecting datain a simple visual reaction time experiment, as part of a fatigue testing protocol known as the Psychomotor Vigilance Test (PVT). In this protocol, subjects run a 5-minute block consisting of a sequence of trials in which a visual stimulus appears after an unpredictable variable delay. The subject is required to tap the screen as soon as possible after the appearance of the stimulus. In order to validate the reaction times reported by our program, we had subjects perform the task while a high-speed video camera recorded both the display screen, and a side view of the finger (observed in a mirror). Simple image-processing methods were applied to determine the frames in which the stimulus appeared and disappeared, and in which the finger made and broke contact with the screen. The results demonstrate a systematic delay between the initial contact by the finger and the detection of the touch by the software, having a value of 80 +- 20 milliseconds.

  12. A device for electron gun emittance measurement

    International Nuclear Information System (INIS)

    Aune, B.; Corveller, P.; Jablonka, M.; Joly, J.M.

    1985-05-01

    In order to improve the final emittance of the beam delivered by the ALS electron linac a new gun is going to be installed. To measure its emittance and evaluate the contribution of different factors to emittance growth we have developed an emittance measurement device. We describe the experimental and mathematical procedure we have followed, and give some results of measurements

  13. Simple method for absolute calibration of geophones, seismometers, and other inertial vibration sensors

    International Nuclear Information System (INIS)

    Kann, Frank van; Winterflood, John

    2005-01-01

    A simple but powerful method is presented for calibrating geophones, seismometers, and other inertial vibration sensors, including passive accelerometers. The method requires no cumbersome or expensive fixtures such as shaker platforms and can be performed using a standard instrument commonly available in the field. An absolute calibration is obtained using the reciprocity property of the device, based on the standard mathematical model for such inertial sensors. It requires only simple electrical measurement of the impedance of the sensor as a function of frequency to determine the parameters of the model and hence the sensitivity function. The method is particularly convenient if one of these parameters, namely the suspended mass is known. In this case, no additional mechanical apparatus is required and only a single set of impedance measurements yields the desired calibration function. Moreover, this measurement can be made with the device in situ. However, the novel and most powerful aspect of the method is its ability to accurately determine the effective suspended mass. For this, the impedance measurement is made with the device hanging from a simple spring or flexible cord (depending on the orientation of its sensitive axis). To complete the calibration, the device is weighed to determine its total mass. All the required calibration parameters, including the suspended mass, are then determined from a least-squares fit to the impedance as a function of frequency. A demonstration using both a 4.5 Hz geophone and a 1 Hz seismometer shows that the method can yield accurate absolute calibrations with an error of 0.1% or better, assuming no a priori knowledge of any parameters

  14. A Simple Measure of Price Adjustment Coefficients.

    OpenAIRE

    Damodaran, Aswath

    1993-01-01

    One measure of market efficiency is the speed with which prices adjust to new information. The author develops a simple approach to estimating these price adjustment coefficients by using the information in return processes. This approach is used to estimate t he price adjustment coefficients for firms listed on the NYSE and the A MEX as well as for over-the-counter stocks. The author finds evidence of a lagged adjustment to new information in shorter return intervals for firms in all market ...

  15. A simple method for automatic measurement of excitation functions

    International Nuclear Information System (INIS)

    Ogawa, M.; Adachi, M.; Arai, E.

    1975-01-01

    An apparatus has been constructed to perform the sequence control of a beam-analysing magnet for automatic excitation function measurements. This device is also applied to the feedback control of the magnet to lock the beam energy. (Auth.)

  16. A simple optical fiber device for quantitative fluorescence microscopy of single living cells

    NARCIS (Netherlands)

    van Graft, M.; van Graft, Marja; Oosterhuis, B.; Oosterhuis, Bernard; van der Werf, Kees; de Grooth, B.G.; Greve, Jan

    1993-01-01

    simple and relatively inexpensive system is described for obtaining quantitative fluorescence measurements on single living cells loaded with a fluorescent probe to study cell physiological processes. The light emitted from the fluorescent cells is captured by and transported through an optical

  17. Device for radioactivity measurement of liquid samples

    International Nuclear Information System (INIS)

    Lamaziere, J.

    1983-01-01

    The device for low activity gamma measurements comprises an automatic changer for sample transfer from a conveyor to a measuring chamber. The conveyor includes a horizontal table were are regularly distributed sample holders. A lift allows a vertical motion of a plate for the exposition in front of a detector [fr

  18. Device for measuring well twistings

    Energy Technology Data Exchange (ETDEWEB)

    Kostin, Yu S; Golubin, S V; Keller, V F; Merzheyevskiy, A B; Zdorov, V P

    1982-01-01

    The device for measuring the well twistings with the use of fluids (poured into a vessel and which leave an imprint on the walls), containing a housing and adapter, is distinguished by the fact that in order to improve the accuracy of measurement by obtaining a clear imprint, it is equipped with cylinder that is spring-loaded in relation to the adapter, forming a vessel for fluid with the adapter. The adapter is made of two parts, one of which is made of neutral metal in relation to the fluid, and the other, from active in relation to the same fluid.

  19. Power generating device

    Energy Technology Data Exchange (ETDEWEB)

    Onodera, Toshihiro

    1989-05-02

    The existing power generating device consisting of static components only lacks effective measures to utilize solar energy and maintain power generation, hence it is inevitable to make the device much larger and more complicated in order to utilize it as the primary power source for artificial satellites. In view of the above, in order to offer a power generating device useful for the primary power source for satellites which is simple and can keep power generation by solar energy, this invention proposes a power generating device composed of the following elements: (1) a rectangular parallelopiped No. II superconductor plate; (2) a measure to apply a magnetic field to one face of the above superconductor plate; (3) a measure to provide a temperature difference within the range between the starting temperature and the critical temperature of superconductivity to a pair of faces meeting at right angles with the face to which the magnetic field was applied by the above measure; (4) a measure to provide an electrode on each of the other pair of faces meeting at right angles with the face to which the magnetic field was applied by the above measure and form a closed circuit by connecting the each electrode above to each of a pair of electrodes of the load respectively; and (5) a switching measure which is installed in the closed circuit prepared by the above measure and shuts off the closed circuit when the direction of the electric current running the above closed circuit is reversed. 6 figs.

  20. Device measures static friction of magnetic tape

    Science.gov (United States)

    Cole, P. T.

    1967-01-01

    Device measures the coefficient of static friction of magnetic tape over a range of temperatures and relative humidities. It uses a strain gage to measure the force of friction between a reference surface and the tape drawn at a constant velocity of approximately 0.0001 inch per second relative to the reference surface.

  1. Handheld Device Adapted to Smartphone Cameras for the Measurement of Sodium Ion Concentrations at Saliva-Relevant Levels via Fluorescence

    OpenAIRE

    Lipowicz, Michelle; Garcia, Antonio

    2015-01-01

    The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia) for the measurement of sodium ion levels at physiologi...

  2. Real-time precision measuring device of tree diameter growth

    Science.gov (United States)

    Guo, Mingming; Chen, Aijun; Li, Dongsheng; Liu, Nan; Yao, Jingyuan

    2016-01-01

    DBH(diameter at breast height) is an important factor to reflect of the quality of plant growth, also an important parameter indispensable in forest resources inventory and forest carbon sink, the accurate measurement of DBH or not is directly related to the research of forest resources inventory and forest carbon sink. In this paper, the principle and the mathematical model of DBH measurement device were introduced, the fixture measuring device and the hardware circuit for this tree diameter were designed, the measurement software programs were compiled, and the precision measuring device of tree diameter growth was developed. Some experiments with Australia fir were conducted. Based on experiment data, the correlations among the DBH variation of Australian fir, the environment temperature, air humility and PAR(photosynthetically active radiation) were obtained. The effects of environmental parameters (environment temperature, air humility and PAR) on tree diameter were analyzed. Experimental results show that there is a positive correlation between DBH variation of Australian fir and environment temperature, a negative correlation between DBH variation of Australian fir and air humility , so is PAR.

  3. A simple optical fiber device for quantitative fluorescence microscopy of single living cells

    OpenAIRE

    van Graft, M.; van Graft, Marja; Oosterhuis, B.; Oosterhuis, Bernard; van der Werf, Kees; de Grooth, B.G.; Greve, Jan

    1993-01-01

    simple and relatively inexpensive system is described for obtaining quantitative fluorescence measurements on single living cells loaded with a fluorescent probe to study cell physiological processes. The light emitted from the fluorescent cells is captured by and transported through an optical fiber. After passage through appropriate filters the light is measured using a photomultiplier tube. The optical fiber is mounted in one of the microscope outlets. Signals derived from the photomultipl...

  4. An Innovative Flow-Measuring Device: Thermocouple Boundary Layer Rake

    Science.gov (United States)

    Hwang, Danny P.; Fralick, Gustave C.; Martin, Lisa C.; Wrbanek, John D.; Blaha, Charles A.

    2001-01-01

    An innovative flow-measuring device, a thermocouple boundary layer rake, was developed. The sensor detects the flow by using a thin-film thermocouple (TC) array to measure the temperature difference across a heater strip. The heater and TC arrays are microfabricated on a constant-thickness quartz strut with low heat conductivity. The device can measure the velocity profile well into the boundary layer, about 65 gm from the surface, which is almost four times closer to the surface than has been possible with the previously used total pressure tube.

  5. 30 CFR 75.320 - Air quality detectors and measurement devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Air quality detectors and measurement devices... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Ventilation § 75.320 Air quality detectors and measurement devices. (a) Tests for methane shall be made by a qualified person with...

  6. Development and optimization of a device for diferencial pressure measurement

    International Nuclear Information System (INIS)

    Santarine, G.A.

    1980-01-01

    The measurements of reduced values of diferencial pressure, are studied. Several situations are described where the diferencial pressure accurate measurement is necessary in routine works in the Thermohydraulic Laboratory, as well as, the major pressure measurement devices and their respective range are studied. The development of a device for diferencial pressure measurement followed by the design development of the calibration bench covering the foreseen range, start up tests realization, optimization, calibration, performance analysis and conclusions, is showed. (Author) [pt

  7. Miniature ingestible telemeter devices to measure deep-body temperature

    Science.gov (United States)

    Pope, J. M.; Fryer, T. B. (Inventor)

    1976-01-01

    A telemetry device comprised of a pill-size ingestible transmitter developed to obtain deep body temperature measurements of a human is described. The device has particular utility in the medical field where deep body temperatures provide an indication of general health.

  8. Device to measure level in a steam drum of NPP

    International Nuclear Information System (INIS)

    Vinogradov, Yu.A.

    1988-01-01

    Gravitation-hydrostatic device for measuring coolant level in a steam drum of NPP is described. The device enables to improve the accuracy and sensitivity of measuring coolant level above and below the submerged perforated sheet of the steam drum and decrease the amount of levelling vessels in the unit by 50%. 1 fig

  9. A simple capacitance sensor for void fraction measurement in gas-liquid two-phase flow

    International Nuclear Information System (INIS)

    Silva, Luiz C.R.P.; Faccini, José L.H.; Farias, Marcos S.; Su, Jian

    2017-01-01

    In this work we present a simple and inexpensive capacitance sensor for time averaging void fraction measurement of gas-liquid two-phase flow, which was developed at Experimental Thermal hydraulics Laboratory in the Nuclear Engineering Institute, IEN/CNEN. The sensor is a non-invasive device causing no flow disturbances. It is formed by two parallel plates and four electronic circuits: a signal input circuit, an amplification circuit, a frequency generator, and a power supply circuit. The frequency generator applies a sinusoidal signal with appropriate frequency into the signal input circuit which converts the capacitance variation value (or void fraction) of the two-phase flow into a voltage signal that goes to the amplifier stage; the output signal of the amplifier stage will be an input to an analogic/digital converter, installed inside of a computer, and it will provide interpretation of the signal behavior. The capacitance sensor was calibrated by using a horizontal acrylic tube filled with a known volume of water. (author)

  10. A simple capacitance sensor for void fraction measurement in gas-liquid two-phase flow

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Luiz C.R.P.; Faccini, José L.H.; Farias, Marcos S., E-mail: reina@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Su, Jian, E-mail: sujian@con.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Instituto de Engenharia Nuclear

    2017-07-01

    In this work we present a simple and inexpensive capacitance sensor for time averaging void fraction measurement of gas-liquid two-phase flow, which was developed at Experimental Thermal hydraulics Laboratory in the Nuclear Engineering Institute, IEN/CNEN. The sensor is a non-invasive device causing no flow disturbances. It is formed by two parallel plates and four electronic circuits: a signal input circuit, an amplification circuit, a frequency generator, and a power supply circuit. The frequency generator applies a sinusoidal signal with appropriate frequency into the signal input circuit which converts the capacitance variation value (or void fraction) of the two-phase flow into a voltage signal that goes to the amplifier stage; the output signal of the amplifier stage will be an input to an analogic/digital converter, installed inside of a computer, and it will provide interpretation of the signal behavior. The capacitance sensor was calibrated by using a horizontal acrylic tube filled with a known volume of water. (author)

  11. Simple and Low-Cost Wireless Distributed Measurement System

    Directory of Open Access Journals (Sweden)

    Alessandra Flammini

    2007-07-01

    Full Text Available This paper describes the design and realization of a simple and low-cost system for distributed measurements. Traditional handheld digital multimeters have been equipped with a radio-frequency interface in order to implement what the authors call WDMM, the basic block of a wireless multi-probe data logger. New functionalities require very few components and result in a cost increase of less than 10$. In addition, also maintenance has been facilitated since tracking data such as working state or last calibration time are available to the user. Data inquiry can be performed by a purposely designed module that has the same hardware of the WDMM but a different user interface or by a PDA (Personal Digital Assistant or a traditional personal computer thanks to a USB connection. Simple supervisory software has been realized under the LabVIEW graphical programming environment.

  12. Accuracy of an improved device for remote measuring of tree-trunk diameters

    International Nuclear Information System (INIS)

    Matsushita, T.; Kato, S.; Komiyama, A.

    2000-01-01

    For measuring the diameters of tree trunks from a distant position, a recent device using a laser beam was developed by Kantou. We improved this device to serve our own practical purposes. The improved device consists of a 1-m-long metal caliper and a small telescope sliding smoothly onto it. Using the cross hairs in the scope, one can measure both edges of an object on the caliper and calculate its length. The laser beam is used just for guiding the telescopic sights to the correct positions on the object. In this study, the accuracy of this new device was examined by measuring objects of differing lengths, the distance from the object, and the angle of elevation to the object. Since each result of the experiment predicted absolute errors of measurement of less than 3 mm, this new device will be suitable for the measurement of trunk diameters in the field

  13. Small Device For Short-Range Antenna Measurements Using Optics

    DEFF Research Database (Denmark)

    Yanakiev, Boyan Radkov; Nielsen, Jesper Ødum; Christensen, Morten

    2011-01-01

    This paper gives a practical solution for implementing an antenna radiation pattern measurement device using optical fibers. It is suitable for anechoic chambers as well as short range channel sounding. The device is optimized for small size and provides a cheap and easy way to make optical antenna...

  14. SHORT COMMUNICATION: Time measurement device with four femtosecond stability

    Science.gov (United States)

    Panek, Petr; Prochazka, Ivan; Kodet, Jan

    2010-10-01

    We present the experimental results of extremely precise timing in the sense of time-of-arrival measurements in a local time scale. The timing device designed and constructed in our laboratory is based on a new concept using a surface acoustic wave filter as a time interpolator. Construction of the device is briefly described. The experiments described were focused on evaluating the timing precision and stability. Low-jitter test pulses with a repetition frequency of 763 Hz were generated synchronously to the local time base and their times of arrival were measured. The resulting precision of a single measurement was typically 900 fs RMS, and a timing stability TDEV of 4 fs was achieved for time intervals in the range from 300 s to 2 h. To our knowledge this is the best value reported to date for the stability of a timing device. The experimental results are discussed and possible improvements are proposed.

  15. Improving the accuracy of smart devices to measure noise exposure.

    Science.gov (United States)

    Roberts, Benjamin; Kardous, Chucri; Neitzel, Richard

    2016-11-01

    Occupational noise exposure is one of the most frequent hazards present in the workplace; up to 22 million workers have potentially hazardous noise exposures in the U.S. As a result, noise-induced hearing loss is one of the most common occupational injuries in the U.S. Workers in manufacturing, construction, and the military are at the highest risk for hearing loss. Despite the large number of people exposed to high levels of noise at work, many occupations have not been adequately evaluated for noise exposure. The objective of this experiment was to investigate whether or not iOS smartphones and other smart devices (Apple iPhones and iPods) could be used as reliable instruments to measure noise exposures. For this experiment three different types of microphones were tested with a single model of iPod and three generations of iPhones: the internal microphones on the device, a low-end lapel microphone, and a high-end lapel microphone marketed as being compliant with the International Electrotechnical Commission's (IEC) standard for a Class 2-microphone. All possible combinations of microphones and noise measurement applications were tested in a controlled environment using several different levels of pink noise ranging from 60-100 dBA. Results were compared to simultaneous measurements made using a Type 1 sound level measurement system. Analysis of variance and Tukey's honest significant difference (HSD) test were used to determine if the results differed by microphone or noise measurement application. Levels measured with external microphones combined with certain noise measurement applications did not differ significantly from levels measured with the Type 1 sound measurement system. Results showed that it may be possible to use iOS smartphones and smart devices, with specific combinations of measurement applications and calibrated external microphones, to collect reliable, occupational noise exposure data under certain conditions and within the limitations of the

  16. Test device for measuring permeability of a barrier material

    Science.gov (United States)

    Reese, Matthew; Dameron, Arrelaine; Kempe, Michael

    2014-03-04

    A test device for measuring permeability of a barrier material. An exemplary device comprises a test card having a thin-film conductor-pattern formed thereon and an edge seal which seals the test card to the barrier material. Another exemplary embodiment is an electrical calcium test device comprising: a test card an impermeable spacer, an edge seal which seals the test card to the spacer and an edge seal which seals the spacer to the barrier material.

  17. Verification of simple illuminance based measures for indication of discomfort glare from windows

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth; Heiselberg, Per Kvols; Bryn, Ida

    2015-01-01

    predictions of discomfort glare from windows already in the early design stage when decisions regarding the façade are taken. This study focus on verifying if simple illuminance based measures like vertical illuminance at eye level or horizontal illuminance at the desk are correlated with the perceived glare...... reported by 44 test subjects in a repeated measure design occupant survey and if the reported glare corresponds with the predictions from the simple Daylight Glare Probability (DGPs) model. Large individual variations were seen in the occupants’ assessment of glare in the present study. Yet, the results...... confirm that there is a statistically significant correlation between both vertical eye illuminance and horizontal illuminance at the desk and the occupants’ perception of glare in a perimeter zone office environment, which is promising evidence towards utilizing such simple measures for indication...

  18. Reactor power measuring device

    International Nuclear Information System (INIS)

    Izumi, Mikio; Sano, Yuji; Seki, Eiji; Yoshida, Toshifumi; Ito, Toshiaki.

    1993-01-01

    The present invention provides a self-powered long detector having a sensitivity over the entire length of a reactor core as an entire control rod withdrawal range of a BWR type reactor, and a reactor power measuring device using a gamma ray thermometer which scarcely causes sensitivity degradation. That is, a hollow protection pipe is disposed passing through the reactor core from the outside of a reactor pressure vessel. The self-powered long detectors and the gamma ray thermometers are inserted and installed in the protection pipe. An average reactor power in an axial direction of the reactor relative to a certain position in the horizontal cross section of the reactor core is determined based on the power of the self-powered long detector over the entire length of the reactor core. Since the response of the self-powered detector relative to a local power change is rapid, the output is used as an input signal to a safety protection device of the reactor core. Further, a gamma ray thermometer secured in the reactor and having scarce sensitivity degradation is used instead of an incore travelling neutron monitor used for relative calibration of an existent neutron monitor secured in the reactor. (I.S.)

  19. In Situ TEM Creation and Electrical Characterization of Nanowire Devices

    DEFF Research Database (Denmark)

    Kallesøe, Christian; Wen, Cheng-Yen; Booth, Timothy J.

    2012-01-01

    bridge devices in situ and relate these to the structure. We also describe processes to modify the contact and the nanowire surface after device formation. The technique we describe allows the direct analysis of the processes taking place during device formation and use, correlating specific nanoscale......We demonstrate the observation and measurement of simple nanoscale devices over their complete lifecycle from creation to failure within a transmission electron microscope. Devices were formed by growing Si nanowires, using the vapor–liquid–solid method, to form bridges between Si cantilevers. We...... structural and electrical parameters on an individual device basis....

  20. Simultaneous pre-concentration and separation on simple paper-based analytical device for protein analysis.

    Science.gov (United States)

    Niu, Ji-Cheng; Zhou, Ting; Niu, Li-Li; Xie, Zhen-Sheng; Fang, Fang; Yang, Fu-Quan; Wu, Zhi-Yong

    2018-02-01

    In this work, fast isoelectric focusing (IEF) was successfully implemented on an open paper fluidic channel for simultaneous concentration and separation of proteins from complex matrix. With this simple device, IEF can be finished in 10 min with a resolution of 0.03 pH units and concentration factor of 10, as estimated by color model proteins by smartphone-based colorimetric detection. Fast detection of albumin from human serum and glycated hemoglobin (HBA1c) from blood cell was demonstrated. In addition, off-line identification of the model proteins from the IEF fractions with matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was also shown. This PAD IEF is potentially useful either for point of care test (POCT) or biomarker analysis as a cost-effective sample pretreatment method.

  1. SU-F-T-486: A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)

    Energy Technology Data Exchange (ETDEWEB)

    Herchko, S; Ding, G [Vanderbilt University, Nashville, TN (United States)

    2016-06-15

    Purpose: To develop an accurate, straightforward, and user-independent method for performing light versus radiation field coincidence quality assurance utilizing EPID images, a simple phantom made of readily-accessible materials, and a free software program. Methods: A simple phantom consisting of a blocking tray, graph paper, and high-density wire was constructed. The phantom was used to accurately set the size of a desired light field and imaged on the electronic portal imaging device (EPID). A macro written for use in ImageJ, a free image processing software, was then use to determine the radiation field size utilizing the high density wires on the phantom for a pixel to distance calibration. The macro also performs an analysis on the measured radiation field utilizing the tolerances recommended in the AAPM Task Group #142. To verify the accuracy of this method, radiochromic film was used to qualitatively demonstrate agreement between the film and EPID results, and an additional ImageJ macro was used to quantitatively compare the radiation field sizes measured both with the EPID and film images. Results: The results of this technique were benchmarked against film measurements, which have been the gold standard for testing light versus radiation field coincidence. The agreement between this method and film measurements were within 0.5 mm. Conclusion: Due to the operator dependency associated with tracing light fields and measuring radiation fields by hand when using film, this method allows for a more accurate comparison between the light and radiation fields with minimal operator dependency. Removing the need for radiographic or radiochromic film also eliminates a reoccurring cost and increases procedural efficiency.

  2. SU-F-T-486: A Simple Approach to Performing Light Versus Radiation Field Coincidence Quality Assurance Using An Electronic Portal Imaging Device (EPID)

    International Nuclear Information System (INIS)

    Herchko, S; Ding, G

    2016-01-01

    Purpose: To develop an accurate, straightforward, and user-independent method for performing light versus radiation field coincidence quality assurance utilizing EPID images, a simple phantom made of readily-accessible materials, and a free software program. Methods: A simple phantom consisting of a blocking tray, graph paper, and high-density wire was constructed. The phantom was used to accurately set the size of a desired light field and imaged on the electronic portal imaging device (EPID). A macro written for use in ImageJ, a free image processing software, was then use to determine the radiation field size utilizing the high density wires on the phantom for a pixel to distance calibration. The macro also performs an analysis on the measured radiation field utilizing the tolerances recommended in the AAPM Task Group #142. To verify the accuracy of this method, radiochromic film was used to qualitatively demonstrate agreement between the film and EPID results, and an additional ImageJ macro was used to quantitatively compare the radiation field sizes measured both with the EPID and film images. Results: The results of this technique were benchmarked against film measurements, which have been the gold standard for testing light versus radiation field coincidence. The agreement between this method and film measurements were within 0.5 mm. Conclusion: Due to the operator dependency associated with tracing light fields and measuring radiation fields by hand when using film, this method allows for a more accurate comparison between the light and radiation fields with minimal operator dependency. Removing the need for radiographic or radiochromic film also eliminates a reoccurring cost and increases procedural efficiency.

  3. UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; John L. Morrison; William H. Morrison

    2014-03-01

    Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of

  4. Construction of a Simple Low-Cost Teslameter and Its Use with Arduino and MakerPlot Software

    Science.gov (United States)

    Atkin, Keith

    2016-01-01

    This paper shows how it is possible to construct a very simple device for the measurement of magnetic flux densities in an educational context. It is also shown how such a device can be interfaced to a microcontroller with plotting-software to facilitate the study of magnetic fields produced by a current-carrying coil.

  5. Design and development of a device to measure the deformities of clubfoot.

    Science.gov (United States)

    Khas, Kanwaljit S; Pandey, Pulak M; Ray, Alok R

    2015-03-01

    Clubfoot describes a range of foot abnormalities usually present at birth, in which the foot of a baby is twisted out of shape or position. In order to develop an effective treatment plan for clubfoot and/or assess the extent to which existing interventions are successful, medical practitioners need to be able to accurately measure the nature and extent of the deformity. This is typically performed using a goniometer. However, this device is only able to measure one dimension at a time. As such, a complete assessment of the condition of a foot can be extremely burdensome and time-consuming. This article describes a new device that can quickly and efficiently take several measurements on feet of various sizes and shapes. The use of this device was verified by measuring the deformities of real clubfeet. A silicone rubber clubfoot model was also used in this study to clearly illustrate the effectiveness with which the proposed device can measure the various deformities of clubfoot. It is envisaged that the use of this device will significantly reduce the time and effort orthopedists require to measure clubfoot deformities and develop and assess treatment plans. © IMechE 2015.

  6. A simple mechanism for measuring and adjusting distraction forces during maxillary advancement.

    Science.gov (United States)

    Suzuki, Eduardo Yugo; Suzuki, Boonsiva

    2009-10-01

    Direct measurement of distraction forces on the craniofacial skeleton has never been reported. The present report describes the development of a method of assessing and adjusting traction forces applied through maxillary distraction osteogenesis. A simple mechanism to measure and adjust tension force during maxillary distraction osteogenesis was developed and connected bilaterally to the traction screws of a rigid external distraction device. Measurements were carried out before and after activation using a Shimpo (Nidec-Shimpo America Corporation, Itasca, IL) force gauge in 4 patients (2 with unilateral cleft lip and/or palate, 1 with bilateral cleft lip and palate, and 1 with noncleft) during the distraction process. Activation was performed twice a day at a rate of 1 mm/day. The average maximum force applied throughout the distraction period was 42.5 N (range 16.4 to 65.3 N), with increments, after activation, averaging 10.5 N (range 7.9 to 15.7 N). In patients with unilateral cleft lip and/or palate, distraction forces on the larger segment were 65.1% higher than on the lesser segment. A differential pattern of forces was also observed in the patients with asymmetric noncleft. However, the differential forces between lateral segments were not observed in the patient with bilateral cleft lip and palate. During the activation period, distraction forces progressively increased, whereas the amount of maxillary movement decreased. Pain and discomfort were reported with high forces. Through this mechanism, direct measurement and adjustment of distraction forces during maxillary advancement was possible. The unbalanced pattern of forces observed in patients with cleft suggests the necessity of individual adjustments for controlling pain and clinical symptoms. Accordingly, assessment of distraction forces during maxillary distraction osteogenesis is extremely helpful in understanding the biomechanics of the distraction process.

  7. Fabrication of integrated metallic MEMS devices

    DEFF Research Database (Denmark)

    Yalcinkaya, Arda Deniz; Ravnkilde, Jan Tue; Hansen, Ole

    2002-01-01

    A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators are characteri......A simple and complementary metal oxide semiconductor (CMOS) compatible fabrication technique for microelectromechanical (MEMS) devices is presented. The fabrication technology makes use of electroplated metal layers. Among the fabricated devices, high quality factor microresonators...

  8. A simple vibrating sample magnetometer for macroscopic samples

    Science.gov (United States)

    Lopez-Dominguez, V.; Quesada, A.; Guzmán-Mínguez, J. C.; Moreno, L.; Lere, M.; Spottorno, J.; Giacomone, F.; Fernández, J. F.; Hernando, A.; García, M. A.

    2018-03-01

    We here present a simple model of a vibrating sample magnetometer (VSM). The system allows recording magnetization curves at room temperature with a resolution of the order of 0.01 emu and is appropriated for macroscopic samples. The setup can be mounted with different configurations depending on the requirements of the sample to be measured (mass, saturation magnetization, saturation field, etc.). We also include here examples of curves obtained with our setup and comparison curves measured with a standard commercial VSM that confirms the reliability of our device.

  9. Users want simple control over device selection

    NARCIS (Netherlands)

    Misker, J.M.V.; Lindenberg, J.; Neerincx, M.A.

    2005-01-01

    When users want to combine various resources in an ambient intelligent environment in an ad hoc manner, they need to be able to identify and select these resources. We conducted an experiment to study various user interaction styles for combining input and output devices in an ambient intelligent

  10. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    International Nuclear Information System (INIS)

    Elshurafa, Amro M; El-Masry, Ezz I

    2010-01-01

    This paper, the first in a series of two, presents a paradigm shift in the design of MEMS parallel plate PolyMUMPS variable capacitance devices by proposing two structures that utilize the substrate and are able to provide predetermined, customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices where the tuning range is fixed and cannot be varied. Theoretical analysis is carried out and verified with measurements of fabricated devices. The first proposed device possessed initially a tuning range of 4.4. Two variations of the structure having tuning ranges of 3 and 3.4, all at 1 GHz, were also successfully developed and tested. The second proposed variable capacitance device behaved as a switch.

  11. A simple approach to measure the surface resistivity of insulating materials

    DEFF Research Database (Denmark)

    Yang, Zhenyu; Wang, Qian

    2011-01-01

    A simple approach for measuring high surface resistivity of insulating materials using standard laboratory equipments is proposed. The developed system consists of a DC power transformer, a concentric ring probe assembly and a digital multi-meter. The DC power transformer can provide either 500V ...... for different materials, source voltages, and serially connected resistors. The testing results showed that the developed system and methods can provide a reasonably accurate measurement of surface resistivity of insulating materials in a robust and economic manner.......A simple approach for measuring high surface resistivity of insulating materials using standard laboratory equipments is proposed. The developed system consists of a DC power transformer, a concentric ring probe assembly and a digital multi-meter. The DC power transformer can provide either 500V...... or 250V DC signal. The probe assembly is constructed according to Danish Standard (DS/EN 1149-1:2006). The multi-meter (Agilent 3440 1A 6½) is used to measure the micro voltage over a known resistor which is serially connected with electrodes in the probe assembly. In order to obtain reliable...

  12. A handheld optical device for skin profile measurement

    Science.gov (United States)

    Sun, Jiuai; Liu, Xiaojin

    2018-04-01

    This paper describes a portable optical scanning device designed for skin surface measurement on both colour and 3D geometry through a relative easy and cost effective multiple light source photometric stereo method. The validation of colour recovered had been verified through its application on skin lesion segmentation in our early work. This paper focuses on the reconstructed topographic data which are subject to further evaluation and advancement. The evaluation work takes the skin in vitro as an application scenario and compares the experimental result to that obtained by using a commercial product. The experiments show that this handheld device can measure the skin profile significantly closer to that of the ground truth and have the additional function of skin colour recovery.

  13. Measuring devices for the modular switch system; Messgeraete fuer den Schaltschrank

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, Rudolf [Janitza Electronics GmbH, Lahnau (Germany). Sales und Marketing

    2008-10-15

    The advantages of digital universal measuring instruments are: lower device cost for more information and functionality. Furtheron digital measuring technology is more exactly during service life. Cost advantages result due to low installation cost and reduced installation of wires and cables. So universal devices replace all analogue systems and offer further functions. (orig./GL)

  14. Handheld Device Adapted to Smartphone Cameras for the Measurement of Sodium Ion Concentrations at Saliva-Relevant Levels via Fluorescence

    Directory of Open Access Journals (Sweden)

    Michelle Lipowicz

    2015-06-01

    Full Text Available The use of saliva sampling as a minimally-invasive means for drug testing and monitoring physiology is a subject of great interest to researchers and clinicians. This study describes a new optical method based on non-axially symmetric focusing of light using an oblate spheroid sample chamber. The device is simple, lightweight, low cost and is easily attached to several different brands/models of smartphones (Apple, Samsung, HTC and Nokia for the measurement of sodium ion levels at physiologically-relevant saliva concentrations. The sample and fluorescent reagent solutions are placed in a specially-designed, lightweight device that excludes ambient light and concentrates 470-nm excitation light, from a low-power photodiode, within the sample through non-axially-symmetric refraction. The study found that smartphone cameras and post-image processing quantitated sodium ion concentration in water over the range of 0.5–10 mM, yielding best-fit regressions of the data that agree well with a data regression of microplate luminometer results. The data suggest that fluorescence can be used for the measurement of salivary sodium ion concentrations in low-resource or point-of-care settings. With further fluorescent assay testing, the device may find application in a variety of enzymatic or chemical assays.

  15. Single-Image Distance Measurement by a Smart Mobile Device.

    Science.gov (United States)

    Chen, Shangwen; Fang, Xianyong; Shen, Jianbing; Wang, Linbo; Shao, Ling

    2017-12-01

    Existing distance measurement methods either require multiple images and special photographing poses or only measure the height with a special view configuration. We propose a novel image-based method that can measure various types of distance from single image captured by a smart mobile device. The embedded accelerometer is used to determine the view orientation of the device. Consequently, pixels can be back-projected to the ground, thanks to the efficient calibration method using two known distances. Then the distance in pixel is transformed to a real distance in centimeter with a linear model parameterized by the magnification ratio. Various types of distance specified in the image can be computed accordingly. Experimental results demonstrate the effectiveness of the proposed method.

  16. 40 CFR 1065.275 - N2O measurement devices.

    Science.gov (United States)

    2010-07-01

    ... measurement devices. (a) General component requirements. We recommend that you use an analyzer that meets the... functions of other gaseous measurements and the engine's known or assumed fuel properties. The target value... gaseous measurements. The target value for any compensation algorithm is 0.0% (that is, no bias high and...

  17. The making of pressure measurement device on heating-02 based realtime

    International Nuclear Information System (INIS)

    Giarno; Kussigit Santosa; Agus Nur Rachman; G B Heru K

    2013-01-01

    In order to modify the installation strand BETA Test Section Test integrated with heating-02 into a closed loop, it would require an additional system that can measure pressure changes in the closed-loop system. By making the measurement device to test the system pressure at the heating-expected 02 researchers can monitor the pressure changes that occur in the system. The pressure gauge device fabrication using manufacturing simulation methodology, the preparation of the hardware and software and test functions. Manufacturing simulation using measuring devices HIOKI DC current source Signal Source, preparation of pressure measurement devices require hardware such as pressure transducers, NI cRIO-9074, NI 9203 analog module, Computer and software LabVIEW 2011 as programming. In the test process function method is used to provide flow simulation module that is connected to the 9203 NI NI cRIO-9074. Current provision tailored to the specifics pressure transducer is 4 mA s/d 20 mA. Based on the test results obtained function value of the lowest current is 4.00 mA = 0.001 bar, and the highest current value of 20.00 mA = 4995 bar. From the results of calculations using the linear equations obtained correlation coefficient (R 2 ) of 0.999, so it is evident that the pressure changes in LabVIEW is affected by changes in flow. The results obtained from this activity is a device that can measure the pressure in the heating-02 test. (author)

  18. Novel Simple Insulin Delivery Device Reduces Barriers to Insulin Therapy in Type 2 Diabetes: Results From a Pilot Study

    OpenAIRE

    Hermanns, Norbert; Lilly, Leslie C.; Mader, Julia K.; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R.

    2015-01-01

    Background: The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. Methods: This singl...

  19. Radiation dose measurements of the insertion devices using radiachromic film dosimeters

    International Nuclear Information System (INIS)

    Alderman, J.; Semones, E.; Job, P. K.

    2004-01-01

    The Advanced Photon Source (APS) uses Nd-Fe-B permanent magnets in the insertion devices to produce x-rays for scientific research [1,2]. Earlier investigations have exhibited varying degrees of demagnetization of these magnets [3] due to irradiation from electron beams [4,5,6], 60 Co γ-rays [5], and high-energy neutrons [7,8]. Radiation-induced demagnetization has been observed in the APS insertion devices [9] and was first measured in December of 2001. Partial demagnetization has also been observed in insertion devices at the European Synchrotron Radiation Facility (ESRF) [4,6], where Nd-Fe-B permanent magnets are also used. Growing concern for the lifetime of APS insertion devices, as well as the permanent magnets that will be used in next-generation, high-power light sources, like the FEL [10,11], resulted from the partial demagnetization observations made at both facilities. This concern in relation to radiation-induced demagnetization spurred a long-term project to measure and analyze the absorbed doses received by the APS insertion devices. The project required a reliable photon high-dose dosimetry technique capable of measuring absorbed doses greater than 10 6 rad, which was not readily available at the APS. Through a collaboration with the National Institute of Standards and Technology (NIST), one such technique using radiachromic films was considered, tested, and calibrated at the APS. This consequently led to the implementation of radiachromic film dosimetry for measuring the absorbed doses received by the insertion devices for each of the APS runs

  20. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    KAUST Repository

    Elshurafa, Amro M.

    2010-03-22

    This paper, the first in a series of two, presents a paradigm shift in the design of MEMS parallel plate PolyMUMPS variable capacitance devices by proposing two structures that utilize the substrate and are able to provide predetermined, customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices where the tuning range is fixed and cannot be varied. Theoretical analysis is carried out and verified with measurements of fabricated devices. The first proposed device possessed initially a tuning range of 4.4. Two variations of the structure having tuning ranges of 3 and 3.4, all at 1 GHz, were also successfully developed and tested. The second proposed variable capacitance device behaved as a switch. © 2010 IOP Publishing Ltd.

  1. Measurement-device-independent quantum digital signatures

    Science.gov (United States)

    Puthoor, Ittoop Vergheese; Amiri, Ryan; Wallden, Petros; Curty, Marcos; Andersson, Erika

    2016-08-01

    Digital signatures play an important role in software distribution, modern communication, and financial transactions, where it is important to detect forgery and tampering. Signatures are a cryptographic technique for validating the authenticity and integrity of messages, software, or digital documents. The security of currently used classical schemes relies on computational assumptions. Quantum digital signatures (QDS), on the other hand, provide information-theoretic security based on the laws of quantum physics. Recent work on QDS Amiri et al., Phys. Rev. A 93, 032325 (2016);, 10.1103/PhysRevA.93.032325 Yin, Fu, and Zeng-Bing, Phys. Rev. A 93, 032316 (2016), 10.1103/PhysRevA.93.032316 shows that such schemes do not require trusted quantum channels and are unconditionally secure against general coherent attacks. However, in practical QDS, just as in quantum key distribution (QKD), the detectors can be subjected to side-channel attacks, which can make the actual implementations insecure. Motivated by the idea of measurement-device-independent quantum key distribution (MDI-QKD), we present a measurement-device-independent QDS (MDI-QDS) scheme, which is secure against all detector side-channel attacks. Based on the rapid development of practical MDI-QKD, our MDI-QDS protocol could also be experimentally implemented, since it requires a similar experimental setup.

  2. Device for measuring high temperature heat conductivity of solids and melts

    International Nuclear Information System (INIS)

    Magomedov, Ya.B.; Gadzhiev, G.G.

    1990-01-01

    A modification of a device for measuring heat conductivity by a compensation method when a thermocouple with gadolinium sulfide being used is suggested. Such a device has less error of measurement (8%), wider interval of working temperatures (300-1600K) and it permits to investigate the material in the wide range of heat conductivity values (0.5-30 W/(mxK)). The stainless steel 12Kh18N10T, lanthanum sulfide and melted quartz were used for the device calibration. The results obtained and the literature data on these materials agree well between each other

  3. Zero G Mass Measurement Device (ZGMMD), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The Zero G Mass Measurement Device (ZGMMD) will provide the ability to quantify the mass of objects up to 2,000 grams, including live animal specimens in a zero G...

  4. Use of piezoelectric multicomponent force measuring devices in fluid mechanics

    Science.gov (United States)

    Richter, A.; Stefan, K.

    1979-01-01

    The characterisitics of piezoelectric multicomponent transducers are discussed, giving attention to the advantages of quartz over other materials. The main advantage of piezoelectric devices in aerodynamic studies is their ability to indicate rapid changes in the values of physical parameters. Problems in the accuracy of measurments by piezoelectric devices can be overcome by suitable design approaches. A practical example is given of how such can be utilized to measure rapid fluctuations of fluid forces exerted on a circular cylinder mounted in a water channel.

  5. Validation of a laser-assisted wound measurement device in a wound healing model.

    Science.gov (United States)

    Constantine, Ryan S; Bills, Jessica D; Lavery, Lawrence A; Davis, Kathryn E

    2016-10-01

    In the treatment and monitoring of a diabetic or chronic wound, accurate and repeatable measurement of the wound provides indispensable data for the patient's medical record. This study aims to measure the accuracy of the laser-assisted wound measurement (LAWM) device against traditional methods in the measurement of area, depth and volume. We measured four 'healing' wounds in a Play-Doh(®) -based model over five subsequent states of wound healing progression in which the model was irregularly filled in to replicate the healing process. We evaluated the LAWM device against traditional methods including digital photograph assessment with National Institutes of Health ImageJ software, measurements of depth with a ruler and weight-to-volume assessment with dental paste. Statistical analyses included analysis of variance (ANOVA) and paired t-tests. We demonstrate that there are significantly different and nearly statistically significant differences between traditional ruler depth measurement and LAWM device measurement, but there are no statistically significant differences in area measurement. Volume measurements were found to be significantly different in two of the wounds. Rate of percentage change was analysed for volume and depth in the wound healing model, and the LAWM device was not significantly different than the traditional measurement technique. While occasionally inaccurate in its absolute measurement, the LAWM device is a useful tool in the clinician's arsenal as it reliably measures rate of percentage change in depth and volume and offers a potentially aseptic alternative to traditional measurement techniques. © 2014 The Authors. International Wound Journal © 2014 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  6. MowA®: A simple and economic way of monitoring chronic wounds outcome with your mobile devices.

    Science.gov (United States)

    Ciancio, Francesco; Portincasa, Aurelio; Parisi, Domenico; Innocenti, Alessandro

    2017-01-01

    The treatment of skin ulcers of the lower extremities is a difficult challenge for surgeons as demonstrated in the literature 1,2. Furthermore objective monitoring of skin ulcers represts an important necessity for the plastic surgeon who has to update the treatment over time. In the past we had to write about systems and applications designed to catalog and manage digital libraries 3, so we have gone looking for a system to catalog and manage date related skin in ulcers. I present an application for mobile devices that allows to calculate , evaluate and analyze, the both surface area and tissue quality of skin ulcers m in a fast and practical way. The application is called "Mowa®"and it is available both for Apple and Android devices. Often we have to treat chronic injuries to the skin for several weeks and the evaluation needs to takes place in a periodic manner. An important problem for a surgeon, in the treatment of chronic wounds of the skin, is to evaluate the effectiveness of the cure in terms of "reduction of the lesion" and "quality of tissue". That is, it would be useful having s way to assess the size(area) of the wound an quality if tissues inside the lesion. This would make it objectively easier to measure the progress if the treatment in the past there have been many proposed systems 4-6. We tried in the past, to use theVisa-track system (smith & Nephew) with good outcomes, but this is limited because it can be used by a single patient at atime. The need to find a more affordable way led us to experience Mora application in our devices. This simple application allows, through a photograph, to quantify in quare centimeters the surface of the lesion. Furtermore Mowa® provides a system for detecting the fibrin percentage of granulation and necrotic tissue. The analysis of the chronic lesion of the skin is also completed by the insertion of the main characteristics of the qound, for esample, the exudate (in small quantities,moderate or a lot). The

  7. Development of a magnetic measurement device for thin ribbon samples

    International Nuclear Information System (INIS)

    Sato, Yuta; Todaka, Takashi; Enokizono, Masato

    2008-01-01

    This paper presents a magnetic measurement device for thin ribbon samples, which are produced by rapid cooling technique. This device enables us to measure magnetic properties easily by only inserting a ribbon sample into a sample holder. The sample holder was made by bakelite to fix any width sample. A long solenoid coil was used to generate a uniform magnetic field and the sample holder was placed at the mid part of the solenoid. The magnetic field strength was measured using a shunt resistor and the magnetic flux density and magnetization in sample ribbons were evaluated by using search coils. The accuracy of measurement was verified with an amorphous metal ribbon sample. Next, we have measured magnetic properties of some magnetic shape memory alloys, which have different compositions. The measured results are compared and we clarified the effect of Sm contents on the magnetic properties

  8. Door and window image-based measurement using a mobile device

    Science.gov (United States)

    Ma, Guangyao; Janakaraj, Manishankar; Agam, Gady

    2015-03-01

    We present a system for door and window image-based measurement using an Android mobile device. In this system a user takes an image of a door or window that needs to be measured and using interaction measures specific dimensions of the object. The existing object is removed from the image and a 3D model of a replacement is rendered onto the image. The visualization provides a 3D model with which the user can interact. When tested on a mobile Android platform with an 8MP camera we obtain an average measurement error of roughly 0.5%. This error rate is stable across a range of view angles, distances from the object, and image resolutions. The main advantages of our mobile device application for image measurement include measuring objects for which physical access is not readily available, documenting in a precise manner the locations in the scene where the measurements were taken, and visualizing a new object with custom selections inside the original view.

  9. Measuring device for control rod driving time

    International Nuclear Information System (INIS)

    Tanaka, Kazuhiko; Hanabusa, Masatoshi.

    1993-01-01

    The present invention concerns a measuring device for control driving time having a function capable of measuring a selected control rod driving time and measuring an entire control rod driving time simultaneously. A calculation means and a store means for the selected rod control rod driving time, and a calculation means and a store means for the entire control rod driving time are disposed individually. Each of them measures the driving time and stores the data independent of each other based on a selected control rod insert ion signal and an entire control rod insertion signal. Even if insertion of selected and entire control rods overlaps, each of the control rod driving times can be measured reliably to provide an advantageous effect capable of more accurately conducting safety evaluation for the nuclear reactor based on the result of the measurement. (N.H.)

  10. Droids Made Simple

    CERN Document Server

    Mazo, Gary

    2011-01-01

    If you have a Droid series smartphone - Droid, Droid X, Droid 2, or Droid 2 Global - and are eager to get the most out of your device, Droids Made Simple is perfect for you. Authors Martin Trautschold, Gary Mazo and Marziah Karch guide you through all of the features, tips, and tricks using their proven combination of clear instructions and detailed visuals. With hundreds of annotated screenshots and step-by-step directions, Droids Made Simple will transform you into a Droid expert, improving your productivity, and most importantly, helping you take advantage of all of the cool features that c

  11. Compact and high-efficiency device for Raman scattering measurement using optical fibers.

    Science.gov (United States)

    Mitsui, Tadashi

    2014-11-01

    We describe the design and development of a high-efficiency optical measurement device for operation within the small bore of a high-power magnet at low temperature. For the high-efficiency measurement of light emitted from this small region, we designed a compact confocal optics with lens focusing and tilting systems, and used a piezodriven translation stage that allows micron-scale focus control of the sample position. We designed a measurement device that uses 10 m-long optical fibers in order to avoid the influence of mechanical vibration and magnetic field leakage of high-power magnets, and we also describe a technique for minimizing the fluorescence signal of optical fibers. The operation of the device was confirmed by Raman scattering measurements of monolayer graphene on quartz glass with a high signal-to-noise ratio.

  12. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation.

    Science.gov (United States)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-09-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C.Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland-Altman method was used to assess agreement between them.The devices showed agreement in overall tracking of changes in SO2. Test-retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range.Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative.

  13. A pilot study of a new spectrophotometry device to measure tissue oxygen saturation

    International Nuclear Information System (INIS)

    Abel, Gemma; Allen, John; Drinnan, Michael

    2014-01-01

    Tissue oxygen saturation (SO2) measurements have the potential for far wider use than at present but are limited by device availability and portability for many potential applications. A device based on a small, low-cost general-purpose spectrophotometer (the Harrison device) might facilitate wider use. The aim of this study was to compare the Harrison device with a commercial instrument, the LEA O2C. Measurements were carried out on the forearm and finger of 20 healthy volunteers, using a blood pressure cuff on the upper arm to induce different levels of oxygenation. Repeatability of both devices was assessed, and the Bland–Altman method was used to assess agreement between them. The devices showed agreement in overall tracking of changes in SO2. Test–retest agreement for the Harrison device was worse than for O2C, with SD repeatability of 10.6% (forearm) or 18.6% (finger). There was no overall bias between devices, but mean (SD) difference of 1.2 (11.8%) (forearm) or 4.4 (11.5%) (finger) were outside of a clinically acceptable range. Disagreements were attributed to the stability of the Harrison probe and the natural SO2 variations across the skin surface increasing the random error. Therefore, though not equivalent to the LEA O2C, a probe redesign and averaged measurements may help establish the Harrison device as a low cost alternative. (paper)

  14. Simulation and measurement of short infrared pulses on silicon position sensitive device

    International Nuclear Information System (INIS)

    Krapohl, D; Esebamen, O X; Nilsson, H E; Thungstroem, G

    2011-01-01

    Lateral position sensitive devices (PSD) are important for triangulation, alignment and surface measurements as well as for angle measurements. Large PSDs show a delay on rising and falling edges when irradiated with near infra-red light. This delay is also dependent on the spot position relative to the electrodes. It is however desirable in most applications to have a fast response. We investigated the responsiveness of a Sitek PSD in a mixed mode simulation of a two dimensional full sized detector. For simulation and measurement purposes focused light pulses with a wavelength of 850 nm, duration of 1μs and spot size of 280μm were used. The cause for the slopes of rise and fall time is due to time constants of the device capacitance as well as the photo-generation mechanism itself. To support the simulated results, we conducted measurements of rise and fall times on a physical device. Additionally, we quantified the homogeneity of the device by repositioning a spot of light from a pulsed ir-laser diode on the surface area.

  15. A simple algorithm for measuring particle size distributions on an uneven background from TEM images

    DEFF Research Database (Denmark)

    Gontard, Lionel Cervera; Ozkaya, Dogan; Dunin-Borkowski, Rafal E.

    2011-01-01

    Nanoparticles have a wide range of applications in science and technology. Their sizes are often measured using transmission electron microscopy (TEM) or X-ray diffraction. Here, we describe a simple computer algorithm for measuring particle size distributions from TEM images in the presence of a...... application to images of heterogeneous catalysts is presented.......Nanoparticles have a wide range of applications in science and technology. Their sizes are often measured using transmission electron microscopy (TEM) or X-ray diffraction. Here, we describe a simple computer algorithm for measuring particle size distributions from TEM images in the presence...

  16. Radiation detection and measurement concepts, methods and devices

    CERN Document Server

    McGregor, Douglas

    2019-01-01

    This text on radiation detection and measurement is a response to numerous requests expressed by students at various universities, in which the most popularly used books do not provide adequate background material, nor explain matters in understandable terms. This work provides a modern overview of radiation detection devices and radiation measurement methods. The topics selected in the book have been selected on the basis of the author’s many years of experience designing radiation detectors and teaching radiation detection and measurement in a classroom environment.

  17. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  18. Device-dependent and device-independent quantum key distribution without a shared reference frame

    International Nuclear Information System (INIS)

    Slater, Joshua A; Tittel, Wolfgang; Branciard, Cyril; Brunner, Nicolas

    2014-01-01

    Standard quantum key distribution (QKD) protocols typically assume that the distant parties share a common reference frame. In practice, however, establishing and maintaining a good alignment between distant observers is rarely a trivial issue, which may significantly restrain the implementation of long-distance quantum communication protocols. Here we propose simple QKD protocols that do not require the parties to share any reference frame, and study their security and feasibility in both the usual device-dependent (DD) case—in which the two parties use well characterized measurement devices—as well as in the device-independent (DI) case—in which the measurement devices can be untrusted, and the security relies on the violation of a Bell inequality. To illustrate the practical relevance of these ideas, we present a proof-of-principle demonstration of our protocols using polarization entangled photons distributed over a coiled 10-km long optical fiber. We consider two situations, in which either the fiber spool's polarization transformation freely drifts, or randomly chosen polarization transformations are applied. The correlations obtained from measurements allow, with high probability, to generate positive asymptotic secret key rates in both the DD and DI scenarios (under the fair-sampling assumption for the latter case). (paper)

  19. Two devices for atmospheric electric field measurement

    International Nuclear Information System (INIS)

    Colombet, Andre; Hubert, Pierre.

    1977-02-01

    Two instruments installed at St Privat d'Allier for electric field measurement in connection with the rocket triggered lighting experiment program are described. The first one is a radioactive probe electrometer used as a warning device. The second is a field mill used for tape recording of electric field variation during the triggering events. Typical examples of such records are given [fr

  20. Comparative analysis of colour change measurement devices in textile industry

    Directory of Open Access Journals (Sweden)

    Paulina Gilewicz

    2014-08-01

    Full Text Available In the paper there is presented a trial of application of new measurement principle of colour change with the use of DigiEye device. Comparison of DigiEye with commonly use in the textile industry spectrophotometer Macbeth 2020 was an aim of determination of relationship between parameters of both measurement systems. Samples for the colour change assessment on both measurement systems were first aged in the Xenotest 150. Ageing process was done according to the method of blues scale. Results were obtained by the colour measurement devices before and after the ageing test each releasing the diaphragms during exposing the examined samples on the light. Result of colour change were obtained in the colour system CIE L*a*b*. The measurements were done for PES fabrics destined on the outer layers of clothing. [b]Keywords[/b]: textiles, spectrophotometer, colorimeter [b][/b

  1. Gain stabilization circuit of measuring devices with photomultipliers

    International Nuclear Information System (INIS)

    Seda, J.; Sabol, J.

    1974-01-01

    A circuit is designed for the stabilization of the gain of measuring devices with photomultipliers, suitable especially for the stabilization of scintillation detection systems, in which the correction signal is applied to the photomultiplier grid placed between the photocathode and the first dynode. (J.K.)

  2. Accurate and simple measurement method of complex decay schemes radionuclide activity

    International Nuclear Information System (INIS)

    Legrand, J.; Clement, C.; Bac, C.

    1975-01-01

    A simple method for the measurement of the activity is described. It consists of using a well-type sodium iodide crystal whose efficiency mith monoenergetic photon rays has been computed or measured. For each radionuclide with a complex decay scheme a total efficiency is computed; it is shown that the efficiency is very high, near 100%. The associated incertainty is low, in spite of the important uncertainties on the different parameters used in the computation. The method has been applied to the measurement of the 152 Eu primary reference [fr

  3. Measuring Visual Function Using the MultiQuity System: Comparison with an Established Device

    Directory of Open Access Journals (Sweden)

    Patrycja Smolarek-Kasprzak

    2014-01-01

    Full Text Available Purpose. To compare measures of visual acuity (VA and contrast sensitivity (CS from the Thompson Xpert 2000 and MultiQuity (MiQ devices. Methods. Corrected distance VA (CDVA and CS were measured in the right eye of 73 subjects, on an established system (Thompson Xpert and a novel system (MiQ 720. Regression was used to convert MiQ scores into the Thompson scale. Agreement between the converted MiQ and Thompson scores was investigated using standard agreement indices. Test-retest variability for both devices was also investigated, for a separate sample of 24 subjects. Results. For CDVA, agreement was strong between the MiQ and Thomson devices (accuracy = 0.993, precision = 0.889, CCC = 0.883. For CS, agreement was also strong (accuracy = 0.996, precision = 0.911, CCC = 0.907. Agreement was unaffected by demographic variables or by presence/absence of ocular pathology. Test-retest agreement indices for both devices were excellent: in the range 0.88–0.96 for CDVA and in the range 0.90–0.98 for CS. Conclusion. MiQ measurements exhibit strong agreement with corresponding Thomson measurements, and test-retest results are good for both devices. Agreement between the two devices is unaffected by age or ocular pathology.

  4. Novel Simple Insulin Delivery Device Reduces Barriers to Insulin Therapy in Type 2 Diabetes

    Science.gov (United States)

    Hermanns, Norbert; Lilly, Leslie C.; Mader, Julia K.; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R.

    2015-01-01

    Background: The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. Methods: This single-center, open-label, single-arm study comprised three 2-week periods: baseline (MDI), transition from MDI to PaQ, and PaQ treatment. Validated questionnaires were administered during the baseline and PaQ treatment periods: Barriers to Insulin Treatment questionnaire (BIT), Insulin Treatment Appraisal Scale (ITAS), and Problem Areas in Diabetes scale (PAID). Results: Eighteen patients (age 59 ± 5 years, diabetes duration 15 ± 7 years, 21% female, HbA1c 7.7 ± 0.7%) completed the questionnaires. There was a strong, significant effect of PaQ use in mean BIT total scores (difference [D] = −5.4 ± 0.7.7, P = .01, effect size [d] = 0.70). Patients perceived less stigmatization by insulin injection (D = −2.2 ± 6.2, P = .18, d = 0.35), increased positive outcome (D = 1.9 ± 6.6, P = .17, d = 0.29), and less fear of injections (1.3 ± 4.8, P = .55, d = 0.28). Mean change in ITAS scores after PaQ device use showed a nonsignificant improvement of 1.71 ± 5.63 but moderate effect size (d = 0.30, P = .14). No increase in PAID scores was seen. Conclusions: The results and moderate to large effects sizes suggest that PaQ device use has beneficial and clinically relevant effects to overcoming barriers to and negative appraisal of insulin treatment, without increasing other diabetes-related distress. PMID:25670847

  5. Device for measuring the flow rate of a fluid moving through a pipe

    International Nuclear Information System (INIS)

    Barge, Gilles; Bouchard, Patrick; Chaix, J.E.; Rigaud, J.L.; Vivaldi, Andre.

    1981-01-01

    A device is described for measuring the flow rate, in particular through large section pipes, such as those found in water type nuclear reactors, thermal power stations and gas loops. This device includes a plate drilled with holes crossed by a fluid and held in the pipe by deformable components on which are secured strain gauges forming the detecting element of an electronic device for processing the signal emitted by the gauges. This device can be employed, for instance, for measuring the flow rate of a coolant in the primary system of a nuclear reactor [fr

  6. Development and evaluation of measurement devices used to support testing of radioactive material transportation packages

    International Nuclear Information System (INIS)

    Uncapher, W.L.; Ammerman, D.J.; Stenberg, D.R.; Bronowski, D.R.; Arviso, M.

    1992-01-01

    Radioactive material package designers use structural testing to verify and demonstrate package performance. A major part of evaluating structural response is the collection of instrumentation measurement data. Sandia National Laboratories (SNL) has an ongoing program to develop and evaluate measurement devices to support testing of radioactive material packages. Measurement devices developed in support of this activity include evaluation channels, ruggedly constructed linear variable differential transformers, and piezoresistive accelerometers with enhanced measurement capabilities. In addition to developing measurement devices, a method has been derived to evaluate accelerometers and strain gages for measurement repeatability, ruggedness, and manufacturers' calibration data under both laboratory and field conditions. The developed measurement devices and evaluation technique will be discussed and the results of the evaluation will be presented

  7. Design of the device of auto-measuring radon continuously based on FPGA

    International Nuclear Information System (INIS)

    Wang Yan; Shen Zhengqin; Chen Qiong

    2004-01-01

    This paper introduces the design of the device of auto-measuring radon continuously. The core of the system is the design of controlling system by FPGA, which consists of preset module, electrical calendar module and driving module. The system can automatically measure the consistence of the radon and the separating out rate of it. The information data is displayed by LCD. The high speed micro printer is used to print the measuring result. It adopts FPGA to design the measuring system of the device, which can improve the precision and stability of the system. (authors)

  8. The development of an enhanced strain measurement device to support testing of radioactive material packages

    International Nuclear Information System (INIS)

    Uncapkher, W.L.; Arviso, M.

    1995-01-01

    Radioactive material package designers use structural testing to verify and demonstrate package performance. A major part of evaluating structural response is the collection of reliable instrumentation measurement data. Over the last four decades, Sandia National Laboratories (SNL) has been actively involved in the development, testing, and evaluation of measurement devices for a broad range of applications, resulting in the commercialization of several measurement devices commonly used today. SNL maintains an ongoing program sponsored by the US Department of Energy (DOE) to develop and evaluate measurement devices to support testing of packages used to transport radioactive or hazardous materials. The development of the enhanced strain measurement device is part of this program

  9. Head-Impact–Measurement Devices: A Systematic Review

    Science.gov (United States)

    O'Connor, Kathryn L.; Rowson, Steven; Duma, Stefan M.; Broglio, Steven P.

    2017-01-01

    Context: With an estimated 3.8 million sport- and recreation-related concussions occurring annually, targeted prevention and diagnostic methods are needed. Biomechanical analysis of head impacts may provide quantitative information that can inform both prevention and diagnostic strategies. Objective: To assess available head-impact devices and their clinical utility. Data Sources: We performed a systematic search of the electronic database PubMed for peer-reviewed publications, using the following phrases: accelerometer and concussion, head impact telemetry, head impacts and concussion and sensor, head impacts and sensor, impact sensor and concussion, linear acceleration and concussion, rotational acceleration and concussion, and xpatch concussion. In addition to the literature review, a Google search for head impact monitor and concussion monitor yielded 15 more devices. Study Selection: Included studies were performed in vivo, used commercially available devices, and focused on sport-related concussion. Data Extraction: One author reviewed the title and abstract of each study for inclusion and exclusion criteria and then reviewed each full-text article to confirm inclusion criteria. Controversial articles were reviewed by all authors to reach consensus. Data Synthesis: In total, 61 peer-reviewed articles involving 4 head-impact devices were included. Participants in boxing, football, ice hockey, soccer, or snow sports ranged in age from 6 to 24 years; 18% (n = 11) of the studies included female athletes. The Head Impact Telemetry System was the most widely used device (n = 53). Fourteen additional commercially available devices were presented. Conclusions: Measurements collected by impact monitors provided real-time data to estimate player exposure but did not have the requisite sensitivity to concussion. Proper interpretation of previously reported head-impact kinematics across age, sport, and position may inform future research and enable staff clinicians

  10. Measurement campaign on connectivity of mesh networks formed by mobile devices

    DEFF Research Database (Denmark)

    Pietrarca, Beatrice; Sasso, Giovanni; Perrucci, Gian Paolo

    2007-01-01

    This paper reports the results of a measurement campaign on the connectivity level of mobile devices using Bluetooth (BT) to form cooperative mobile mesh networks. Such mobile mesh networks composed of mobile devices are the basis for any peer-to-peer communication like wireless grids or social...

  11. Radiation detector device for measuring ionizing radiation

    International Nuclear Information System (INIS)

    Brake, D. von der.

    1983-01-01

    The device contains a compensating filter circuit, which guarantees measurement of the radiation dose independent of the energy or independent of the energy and direction. The compensating filter circuit contains a carrier tube of a slightly absorbing metal with an order number not higher than 35, which surrounds a tubular detector and which carries several annular filter parts on its surface. (orig./HP) [de

  12. Tests, measurements, and characterization of electro-optic devices and systems

    International Nuclear Information System (INIS)

    Wadekar, S.G.

    1989-01-01

    This book contains the proceedings on tests, measurements and characterization of electro-optic devices and systems. Topics covered include: Measurement of spectral dynamics in single-quantum-well lasers, High power computer controlled laser diode characterization tester, and Laser diode characterization instrumentation

  13. A TECHNIQUE OF MEASURING OF RESISTANCE OF A GROUNDING DEVICE

    Directory of Open Access Journals (Sweden)

    I.V. Nizhevskyi

    2016-06-01

    Full Text Available Introduction. Measurement of resistance of the grounding device (GD by means of a three-electrode system. This requires not only the right choice of installation locations of measuring electrodes, but also the determination of the point of zero potential. Implementation of these requirements quite time-consuming, and in some cases impossible. Aim. Develop a new technique for measuring the electrical resistance of the GD. Task. The method of measuring the resistance of the GD with the help of a three-electrode setup is necessary to exclude the determination of the point of zero potential. Method. Mathematical modeling and calculation engine. Results. A three-electrode system for measuring the resistance of grounding devices (GD for various purposes is considered. On the basis of Maxwell equations a theoretical substantiation of a new technique for measuring the resistance of any GD of any construction in random soil structure has been proposed. An equation system of the sixth order has been obtained, its solution makes it possible to measure its own mutual resistance in the three-electrode installation with sufficiently high accuracy. Peculiarities of drawing up a calculation scheme of substitution of a three-electrode installation with lumped parameters: self and mutual impedance. Use of the principle of reciprocity eliminates the need of finding a point of zero potential which is a rather difficult task. The technique allows to minimize the spacing of measuring electrodes outside the GD, which substantially reduces the length of wiring of the measurement circuit and increases the «signal-to-interference» ratio and also removes the restrictions on the development of the territory outside the GD being tested. Conclusion. The procedure allows to evaluate the self and mutual impedance grounding all the electrodes in a three-electrode measuring installation of the grounding resistance of the device without finding the point of zero potential.

  14. Present status and future of simple measuring methods; Suishitsu kan`i sokutei gijutsu no genjo to hatten no hoko

    Energy Technology Data Exchange (ETDEWEB)

    Urano, K.; Ishii, S. [Yokohama National University, Yokohama (Japan)

    1998-05-10

    This paper discusses simple measuring methods for water quality. There are various purposes for measuring water quality. It is not necessary to measure the water quality in an official way by taking a lot of labor and cost. Simple measuring methods are often adopted. By applying simple methods, measuring points and frequency of main discharge processes can be increased, resulting in the detailed evaluation and monitoring. Easy safety check for earth filling waste and soil pollutants is realized. Daily inspection and atmospheric measurements at accidents and disasters are easily promoted. The simple methods require easy and rapid operation, sensibility, accuracy and reproducibility suitable for the purpose, small size apparatus, low cost for measurements, and safety against used harmful matters. Coloring reaction is utilized for most of the measuring principles of simple methods, which include tests using test papers, pack tests, colorimetric tests, and tests using photoelectric colorimeter. The bacteria detection includes titration methods using dropping bottles, tablets and syringes, and tests using test papers. A measuring kit for the enzyme immunity method is commercialized. Cooperation of experts, measuring operators at the site and citizens is also indispensable. 7 refs., 3 figs., 2 tabs.

  15. A Simple Educational Method for the Measurement of Liquid Binary Diffusivities

    Science.gov (United States)

    Rice, Nicholas P.; de Beer, Martin P.; Williamson, Mark E.

    2014-01-01

    A simple low-cost experiment has been developed for the measurement of the binary diffusion coefficients of liquid substances. The experiment is suitable for demonstrating molecular diffusion to small or large undergraduate classes in chemistry or chemical engineering. Students use a cell phone camera in conjunction with open-source image…

  16. PEPR and other CRT scanning and measuring devices

    Energy Technology Data Exchange (ETDEWEB)

    Pless, Irwin A. (Massachusetts Institute of Technology, Cambridge, MA 02139 (United States))

    1994-07-01

    This talk concentrates on the brief history of the PEPR (Precision Encoding and Pattern Recognition) scanning and measuring device.I restrict this reminiscence to just a short history of PEPR, the other various CRT scanners, a short summary of the capabilities of this scanner and some fond memories. ((orig.))

  17. PEPR and other CRT scanning and measuring devices

    International Nuclear Information System (INIS)

    Pless, Irwin A.

    1994-01-01

    This talk concentrates on the brief history of the PEPR (Precision Encoding and Pattern Recognition) scanning and measuring device.I restrict this reminiscence to just a short history of PEPR, the other various CRT scanners, a short summary of the capabilities of this scanner and some fond memories. ((orig.))

  18. Simple Magnetic Device Indicates Thickness Of Alloy 903

    Science.gov (United States)

    Long, Pin Jeng; Rodriguez, Sergio; Bright, Mark L.

    1995-01-01

    Handheld device called "ferrite indicator" orginally designed for use in determining ferrite content of specimen of steel. Placed in contact with specimen and functions by indicating whether magnet attracted more strongly to specimen or to calibrated reference sample. Relative strength of attraction shows whether alloy overlay thinner than allowable.

  19. Craniospinal versus whole brain irradiation in Medulloblastoma patients, with introduction of utilizing a simple immobilization device

    Directory of Open Access Journals (Sweden)

    Haddad P

    2001-05-01

    Full Text Available Craniospinal irradiation plus posterior fossa boost (CS1 is the standard modality of post-operative treatment of patient with medulloblastoma, but considering the technical difficulties and limited facilities, often whole- brain irradiation plus posterior fossa boost (WBI had been used in our institution until 1991. Tust a retrospective study was undertaken to compare the patients treated by By WBI and CSI for recurrences and disease-free survival (DFS. Files of all medullobalstoma patients treated post-operatively in our department in the 10 – year period of 1986-1996 were reviewed. To obtain the best possible follow- up, a formal inquiry letter was mailed to all patients’ addresses.Total of 72 patients had been treated, with a mean age of 14.7 years and male-to-female ratio of 1.5:1 Thirty –seven patients had been treated by WBI and 35 by CS. A simple wooden device designed and made in our department was used for CSI patients’ set-up and immobilization. Mean radiation dose to posterior fossa was 4, 765 cGy in WBT and 5, 071 cGY in CSI (180-200 cGy fractions. Sixty-two patients (85% came back for follow-up, with 24 recurrences. Only 24% of CSI patients had recurrences, versus 51% in WBI Nearly all Wbi recurrences versus half of the CSI recurrences were spinal. DFS was 39 months in CSI and 26 months in WBI (P<0.001 . in multi-factorial analysis, only the extent of radiation (CSI versus WBI, P<0.001 was statistically significant. Mean age in our patients was higher than what is commonly reported in literature. The immobilization device introduce was a simple and useful accessory to CSI. Considering DFS, CSI in our department was acceptabley comparable to literature results and significantly superior to WBI. With regard to relatively high spinal recurrence rate even in CSI, the importance of suitable spinal cytological and imaging evaluation is again emphasized.

  20. Device for the automatic evaluation of pencil dosimeters

    International Nuclear Information System (INIS)

    Schallopp, B.

    1976-01-01

    In connenction with the automation of radiation protection in nuclear power plants, an automatic reading device has been developed for the direct input of the readings of pencil dosimeters into a computer. Voltage measurements would be simple but are excluded, because the internal electrode of the dosimeter may not be touched, for operational reasons. This paper describes an optical/electronic conversion device in which the reading of the dosimeter is projected onto a Vidicon, scanned, and converted into a digital signal for output to the computer. (orig.) [de

  1. Design and test of 4πβ-γ coincidence measurement device based on DSP technology

    International Nuclear Information System (INIS)

    Zeng Herong; Feng Qijie; Leng Jun; Qian Dazhi; Bai Lixin; Zhang Yiyun

    2012-01-01

    The paper illustrates the hardware and software of the 4πβ-γ coincidence measurement device based on DSP technology in detail. In such device, the single-channel analyzer, gate generator, coincidence circuit and scalar in the traditional coincidence measurement device are replaced by the digital coincidence acquirer which is researched and manufactured by ourselves. Doing so, the measurement efficiency will be respectively improved, and the hardware cost will be lowered. The comparison experiment shows that the design of such device is a success. (authors)

  2. Accuracy Enhancements for Positioning of Mobile Devices in Wireless Communication Networks

    DEFF Research Database (Denmark)

    Figueiras, Joao

    of the physical length of the communication links. Since these solutions do not require integration of additional hardware into the mobile nodes, they are cheap and simple to implement. As a price to pay, accuracy is typically lower in comparison to dedicated positioning systems. Thus, an important challenge...... communication among users, cooperative positioning strategies aim at localizing devices as a group and not as individuals. In order to reach this goal it is necessary to combine measurements from two domains: device-to-device links and cellular links. Since this combination of information......Positioning of mobile devices in wireless communication networks is nowadays being intensively investigated due to the combined benefit of location information and communication. Typical solutions for such scenario rely on robust algorithms that estimate position from indirect measurements...

  3. A Simple Method for Measuring the Verticality of Small-Diameter Driven Wells

    DEFF Research Database (Denmark)

    Kjeldsen, Peter; Skov, Bent

    1994-01-01

    The presence of stones, solid waste, and other obstructions can deflect small-diameter driven wells during installation, leading to deviations of the well from its intended position. This could lead to erroneous results, especially for measurements of ground water levels by water level meters....... A simple method was developed to measure deviations from the intended positions of well screens and determine correction factors required for proper measurement of ground water levels in nonvertical wells. The method is based upon measurement of the hydrostatic pressure in the bottom of a water column...... ground water flow directions....

  4. Cardiac implantable electronic device lead extraction using the lead-locking device system: keeping it simple, safe, and inexpensive with mechanical tools and local anesthesia.

    Science.gov (United States)

    Manolis, Antonis S; Georgiopoulos, Georgios; Metaxa, Sofia; Koulouris, Spyridon; Tsiachris, Dimitris

    2017-10-01

    We have previously reported our successful approach for percutaneous cardiac implantable electronic device (CIED) lead extraction using inexpensive tools, which we have continued over the years. Herein we report the results of the systematic use of a unique stylet, the lead-locking device (LLD), which securely locks the entire lead lumen, aided with non-powered telescoping sheaths in 54 patients to extract 98 CIED leads. This prospective observational clinical study included 38 men and 16 women aged 68.9±13.1 years undergoing lead extraction for device infection (n=46), lead malfunction (n=5), or prior to defibrillator implant (n=3). Leads were in place for 6.7±4.3 years. Infections were more commonly due to Staphylococcus species (n=40). There were 78 pacing (31 ventricular, 37 atrial, 4 VDD, and 6 coronary sinus leads) and 20 defibrillating leads. Using simple traction (6 leads) and the LLD stylets (92 leads) aided with telescoping sheaths (15 patients), 96 (98%) leads in 52 (96.3%) patients were successfully removed, with all but one leads removed using a subclavian approach; in 1 patient, the right femoral approach was also required. In 2 patients, distal fragments from one ventricular pacing and one defibrillating lead could not be removed. Finally, lead removal was completely (52/54) (96.3%) or partially (2/54) (3.7%) successful in 54 patients for 96 of 98 leads (98%) without major complications. Percutaneous lead extraction can be successful with mechanical tools using the LLD locking stylet aided with non-powered telescoping sheaths through a simplified, safe, and inexpensive procedure using local anesthesia.

  5. An electrochemical sensor device for measuring blood ammonia at the point of care.

    Science.gov (United States)

    Brannelly, N T; Killard, A J

    2017-05-15

    The level of ammonia in blood is relevant in a number of medical conditions. While ammonia is a marker of dysfunction, elevated ammonia is itself a serious medical emergency and can lead to significant and permanent neurological impairment if not addressed quickly. Blood ammonia testing is typically performed in the central laboratory. While a number of point of care devices have been developed, these are based on classical enzymatic or colorimetric principles and have not been widely adopted. In this work, an electrochemical sensor device was developed for measuring blood ammonia. The device was based on the deposition of polyaniline nanoparticle films onto screen printed interdigitated electrodes using inkjet printing and their integration into a polymer microfabricated device with a polytetrafluoroethylene membrane. The device required a 52µL serum sample and measured the change in impedance of the sensor with respect to air at 1kHz, 5mV rms. The device was capable of the measurement of ammonia in serum across the physiologically relevant range of 25-200µM (r 2 =0.9984) and had a limit of detection of 12µM (n =3). The device showed no significant issues with common electrochemical interferences in blood. The device was also validated against a commercial spectrophotometric assay which resulted in excellent correlation (r =0.9699, pair (n =12) and could be stored in desiccant for at least five months. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Electrical measuring device for a high temperature reactor

    International Nuclear Information System (INIS)

    Elter, C.; Handel, H.; Schoening, J.; Schmitt, H.

    1982-01-01

    The device for measuring the low or high neutron flux during start-up or at load is accommodated in an armoured guide tube projecting into the floor. A gas-tight capsule is formed as the measuring column with outer dome with a lid solidly connected by a flange to the armoured tube situated on the side wall of the concrete reactor vessel, together with the armoured guide tube. Two shielding shutters prevent the passage of radiation through the armoured tube. (DG) [de

  7. A simple graphical method for measuring inherent safety

    International Nuclear Information System (INIS)

    Gupta, J.P.; Edwards, David W.

    2003-01-01

    Inherently safer design (ISD) concepts have been with us for over two decades since their elaboration by Kletz [Chem. Ind. 9 (1978) 124]. Interest has really taken off globally since the early nineties after several major mishaps occurred during the eighties (Bhopal, Mexico city, Piper-alfa, Philips Petroleum, to name a few). Academic and industrial research personnel have been actively involved into devising inherently safer ways of production. The regulatory bodies have also shown deep interest since ISD makes the production safer and hence their tasks easier. Research funding has also been forthcoming for new developments as well as for demonstration projects. A natural question that arises is as to how to measure ISD characteristics of a process? Several researchers have worked on this [Trans. IChemE, Process Safety Environ. Protect. B 71 (4) (1993) 252; Inherent safety in process plant design, Ph.D. Thesis, VTT Publication Number 384, Helsinki University of Technology, Espoo, Finland, 1999; Proceedings of the Mary Kay O'Connor Process Safety Center Symposium, 2001, p. 509]. Many of the proposed methods are very elegant, yet too involved for easy adoption by the industry which is scared of yet another safety analysis regime. In a recent survey [Trans. IChemE, Process Safety Environ. Prog. B 80 (2002) 115], companies desired a rather simple method to measure ISD. Simplification is also an important characteristic of ISD. It is therefore desirable to have a simple ISD measurement procedure. The ISD measurement procedure proposed in this paper can be used to differentiate between two or more processes for the same end product. The salient steps are: Consider each of the important parameters affecting the safety (e.g., temperature, pressure, toxicity, flammability, etc.) and the range of possible values these parameters can have for all the process routes under consideration for an end product. Plot these values for each step in each process route and compare. No

  8. Light collection optics for measuring flux and spectrum from light-emitting devices

    Science.gov (United States)

    McCord, Mark A.; DiRegolo, Joseph A.; Gluszczak, Michael R.

    2016-05-24

    Systems and methods for accurately measuring the luminous flux and color (spectra) from light-emitting devices are disclosed. An integrating sphere may be utilized to directly receive a first portion of light emitted by a light-emitting device through an opening defined on the integrating sphere. A light collector may be utilized to collect a second portion of light emitted by the light-emitting device and direct the second portion of light into the integrating sphere through the opening defined on the integrating sphere. A spectrometer may be utilized to measure at least one property of the first portion and the second portion of light received by the integrating sphere.

  9. A simple optical method for measuring the vibration amplitude of a speaker

    OpenAIRE

    UEDA, Masahiro; YAMAGUCHI, Toshihiko; KAKIUCHI, Hiroki; SUGA, Hiroshi

    1999-01-01

    A simple optical method has been proposed for measuring the vibration amplitude of a speaker vibrating with a frequency of approximately 10 kHz. The method is based on a multiple reflection between a vibrating speaker plane and a mirror parallel to that speaker plane. The multiple reflection can magnify a dispersion of the laser beam caused by the vibration, and easily make a measurement of the amplitude. The measuring sensitivity ranges between sub-microns and 1 mm. A preliminary experim...

  10. A simple method to measure critical angles for high-sensitivity differential refractometry.

    Science.gov (United States)

    Zilio, S C

    2012-01-16

    A total internal reflection-based differencial refractometer, capable of measuring the real and imaginary parts of the complex refractive index in real time, is presented. The device takes advantage of the phase difference acquired by s- and p-polarized light to generate an easily detectable minimum at the reflected profile. The method allows to sensitively measuring transparent and turbid liquid samples.

  11. Wind Speed Measurement by Paper Anemometer

    Science.gov (United States)

    Zhong, Juhua; Cheng, Zhongqi; Guan, Wenchuan

    2011-01-01

    A simple wind speed measurement device, a paper anemometer, is fabricated based on the theory of standing waves. In providing the working profile of the paper anemometer, an experimental device is established, which consists of an anemometer sensor, a sound sensor, a microphone, paper strips, a paper cup, and sonic acquisition software. It shows…

  12. Quality assessment of graphene: Continuity, uniformity, and accuracy of mobility measurements

    DEFF Research Database (Denmark)

    Mackenzie, David; Buron, Jonas Christian Due; Whelan, Patrick Rebsdorf

    2017-01-01

    . We present a simple framework for assessing the quality and homogeneity of large-area graphene devices. The field effect in both exfoliated graphene devices encapsulated in hexagonal boron nitride and chemical vapor-deposited (CVD) devices was measured in dual current–voltage configurations and used...

  13. Intelligent RF-Based Gesture Input Devices Implemented Using e-Textiles

    Directory of Open Access Journals (Sweden)

    Dana Hughes

    2017-01-01

    Full Text Available We present an radio-frequency (RF-based approach to gesture detection and recognition, using e-textile versions of common transmission lines used in microwave circuits. This approach allows for easy fabrication of input swatches that can detect a continuum of finger positions and similarly basic gestures, using a single measurement line. We demonstrate that the swatches can perform gesture detection when under thin layers of cloth or when weatherproofed, providing a high level of versatility not present with other types of approaches. Additionally, using small convolutional neural networks, low-level gestures can be identified with a high level of accuracy using a small, inexpensive microcontroller, allowing for an intelligent fabric that reports only gestures of interest, rather than a simple sensor requiring constant surveillance from an external computing device. The resulting e-textile smart composite has applications in controlling wearable devices by providing a simple, eyes-free mechanism to input simple gestures.

  14. A cryogenic current-measuring device with nano-ampere resolution at the storage ring TARN II

    International Nuclear Information System (INIS)

    Tanabe, T.; Chida, K.; Shinada, K.

    1999-01-01

    In cooler-ring experiments, an accurate and non-destructive current measurement is essential for determining the reaction cross sections. The lowest current which can be measured by the DC current transformer commonly used so far is some μA. In order to measure a low-beam current from nA to μA, we made a cryogenic current-measuring device using a superconducting quantum interference devices (SQUID), and measured the circulating ion current at the cooler ring TARN II. This paper gives the design and performance of the device

  15. Burnup degree measuring device for spent fuel

    International Nuclear Information System (INIS)

    Doi, Hideo; Imaizumi, Hideki; Endo, Yasumi; Itahara, Kuniyuki.

    1994-01-01

    The present invention provides a small-sized and convenient device for measuring a burnup degree of spent fuels, which can be installed without remodelling an existent fuel storage pool. Namely, a gamma-ray detecting portion incorporates a Cd-Te detector for measuring intensity ratio of gamma-rays. A neutron detecting portion incorporates a fission counter tube. The Cd-Te detector comprises a neutron shielding member for reducing radiation damages and a background controlling plate for reducing low energy gamma-rays entering from a collimator. Since the Cd-Td detector for use in a gamma-ray spectroscopy can be used at a normal temperature and can measure even a relatively strong radiation field, it can measure the intensity of gamma-rays from Cs-137 and Cs-134 in spent fuels accurately at a resolving power of less than 10 keV. Further, in a case where a cooling period is less than one year, gamma-rays from Rh-106 and Nb-95 can also be measured. (I.S.)

  16. A device for automated phase space measurement of ion beams

    International Nuclear Information System (INIS)

    Lukas, J.; Priller, A.; Steier, P.

    2007-01-01

    Equipment for automated phase-space measurements was developed at the VERA Lab. The measurement of the beam's intensity distribution, as well as its relative position with respect to the reference orbit is performed at two locations along the beam line. The device basically consists of moveable slits and a beam profile monitor, which are both coordinated and controlled by an embedded controller. The operating system of the controller is based on Linux with real-time extension. It controls the movement of the slits and records the data synchronized to the movement of the beam profile monitor. The data is sent via TCP/IP to the data acquisition system of VERA where visualization takes place. The duration of one phase space measurement is less than 10 s, which allows for using the device during routine beam tuning

  17. Measurements with the new PHE neutron survey instrument

    International Nuclear Information System (INIS)

    Eakins, J.S.; Tanner, R.J.; Hager, L.G.

    2014-01-01

    A novel design of survey instrument has been developed to accurately estimate ambient dose equivalent from neutrons with energies in the range from thermal to 20 MeV. The device features moderating and attenuating layers to ease measurement of fast and intermediate energy neutrons, combined with guides that channel low-energy neutrons to the single, central detector. A prototype of this device has been constructed and exposed to a set of calibration fields: the resulting measured responses are presented and discussed here, and compared against Monte Carlo data. A simple simulated workplace neutron field has also been developed to test the device. Measured response data have been determined for a prototype design of neutron survey instrument, using facilities at PHE and NPL. In general, the results demonstrated good directional invariance and agreed well with data obtained by Monte Carlo modelling, raising confidence in the accuracy of the response characteristics expected for the device. A simple simulated workplace field has also been developed and characterised, and the performance of the device assessed in it: agreement between measured and modelled results suggests that the device would behave as anticipated in real workplace fields. These performances will be investigated further in the future, as the design makes the transition from a research prototype to a commercially available instrument. (authors)

  18. 21 CFR 886.1450 - Corneal radius measuring device.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Corneal radius measuring device. 886.1450 Section 886.1450 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... corneal size by superimposing the image of the cornea on a scale at the focal length of the lens of a...

  19. DB-1900 low-background measuring device of alpha and beta

    International Nuclear Information System (INIS)

    Liu Hongquan; Gan Jinbang; Chen Qi; Zhao Yunqing

    1997-08-01

    The device is a box-type detector used to measure the emissivity of Alpha and Beta from dry samples under 2π geometry in radionuclide metrology. It is composed of a high efficiency αβ detector with electrostatic screen of zero potential [patent ZL92111938.0 (in China)] and anticoincidence detector in lead chamber, and has been reasonably combined with double anticoincidence technique to form integral equipment. The characteristics of the device are as follows: It can stably measure the emissivity of Alpha and Beta from dry samples with less surface conductivity (the surface resistance of the samples: 13 Ω) in detector. It can measure Beta emissivity from samples in which Alpha coexist with Beta, and discrimination between Alpha and Beta emissivities can be made simultaneously by two paths. It is a good quantitative means for measuring Alpha and Beta radiation in radiometry, radiation protection and environmental protection. It could be used to measure weak radiativity of Alpha and Beta samples from scientific research, minerals, building materials, plastics, medicinal materials, seas and oceans biology, et al. (7 refs., 8 tabs., 17 figs.)

  20. Experimental measurements of out-of-plane vibrations of a simple blisk design using Blade Tip Timing and Scanning LDV measurement methods

    Science.gov (United States)

    Di Maio, D.; Ewins, D. J.

    2012-04-01

    The study of dynamic properties of rotating structures, such as bladed discs, can be conveniently done using simple bladed discs where the blades do not have staggering angles. Simplified design, although not truly representative of real structures, can be easy and economic to manufacture and, still, very helpful for studying specific dynamic properties. An example of this can be called as mass mistune blisk study. Experimental measurements of vibrations of bladed discs under rotating conditions can be performed using Scanning Laser Doppler Vibrometer (SLDV) systems. However, in the aerospace industry, the vibrations of complex bladed discs must be measured under operating conditions which are more hostile than laboratory simulations. The Blade Tip Timing (BTT) measurement method is a measurement technique, which can be used to measure vibrations of bladed discs of an engine aircraft under operating conditions. However, the BTT technique is ineffective when used with a flat bladed disc whose blade vibrations cannot be measured. This can be detrimental when the use of controlled dynamic parameters, such as those obtained from a simple bladed disc design, can improve the confidence for the validation of post-processing software. This paper presents a work about experimental measurements of a simple bladed disc design whose vibrations were measured synchronously by Scanning LDV and BTT measurement systems. A rotating test rig and its mechanical modifications for the installation of the BTT probes are introduced. Implications of rotating a specimen inconsistently are presented so as solutions to obtained constant revolving speed. The experimental comparisons of forced response vibrations measured synchronously at one blade are presented and explained.

  1. Recoil transporter devices

    International Nuclear Information System (INIS)

    Madhavan, N.

    2005-01-01

    The study of sparsely produced nuclear reaction products in the direction of intense primary beam is a challenging task, the pursuit of which has given rise to the advent or several types of selective devices. These range from a simple parallel plate electrostatic deflector to state-of-the-art electromagnetic separators. There is no single device which can satisfy all the requirements of an ideal recoil transporter, simultaneously. An overview of such devices and their building blocks is presented, which may help in the proper choice of the device as per the experimental requirements. (author)

  2. Using Smart Devices to Measure Intermittent Noise in the Workplace

    Directory of Open Access Journals (Sweden)

    Benjamin Roberts

    2017-01-01

    Full Text Available Purpose: To determine the accuracy of smart devices (iPods to measure intermittent noise and integrate a noise dose in the workplace. Materials and Methods: In experiment 1, four iPods were each paired with a Larson Davis Spark dosimeter and exposed to randomly fluctuating pink noise in a reverberant sound chamber. Descriptive statistics and the mean difference between the iPod and its paired dosimeter were calculated for the 1-s data logged measurements. The calculated time weighted average (TWA was also compared between the devices. In experiment 2, 15 maintenance workers and 14 office workers wore an iPod and dosimeter during their work-shift for a maximum of five workdays. A mixed effects linear regression model was used to control for repeated measures and to determine the effect of the device type on the projected 8-h TWA. Results: In experiment 1, a total of 315,306 1-s data logged measurements were made. The interquartile range of the mean difference fell within ±2.0 A-weighted decibels (dBA, which is the standard used by the American National Standards Institute to classify a type 2 sound level meter. The mean difference of the calculated TWA was within ±0.5 dBA except for one outlier. In experiment 2, the results of the mixed effects model found that, on average, iPods measured an 8-h TWA 1.7 dBA higher than their paired dosimeters. Conclusion: This study shows that iPods have the ability to make reasonably accurate noise measurements in the workplace, but they are not as accurate as traditional noise dosimeters.

  3. Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

    Science.gov (United States)

    Kikuya, Masahiro; Chonan, Kenichi; Imai, Yutaka; Goto, Eiji; Ishii, Masao

    2002-04-01

    Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The factors affecting the accuracy of wrist-cuff devices were also studied. The research group to assess the validity of automated blood pressure measuring device consisted of 13 institutes in Japan, which validated two wrist-cuff devices (WC-1 and WC-2) and two arm-cuff devices (AC-1 and AC-2). They used a crossover method, where the comparison was done between auscultation, by two observers by means of a double stethoscope on one arm and the device on the opposite arm or wrist. There was good inter-observer agreement for the auscultation method in each institute (systolic blood pressure (SBP), -0.1 +/- 2.8 mmHg; diastolic blood pressure (DBP), -0.1 +/- 2.6 mmHg, n = 498). The mean difference between auscultation and the device was minimal both in arm-cuff devices (mean difference for AC-1, 2.2/1.9 mmHg, n = 97 and for AC-2, 5.1/2.9 mmHg, n = 136, SBP/DBP) and wrist-cuff devices (mean difference for WC-1, -2.1/1.2 mmHg, n = 173 mmHg and for WC-2, -2.3/-5.6 mmHg, n = 92). The standard deviation of the difference (SDD) in wrist-cuff devices, however (SDD for WC-1, 9.7/7.3 mmHg and for WC-2, 10.2/8.6 mmHg), was larger than that of the arm-cuff devices (SDD for AC-1, 5.6/6.6 mmHg and for AC-2, 6.3/5.1 mmHg). Grading of AC-1 and AC-2 based on criteria of British Hypertension Society was A/A and B/A, respectively, while that of WC-1 and WC-2 was C/B and D/B, respectively. Using the same validation protocol, the results of validation for one device were divergent in each institute. In wrist-cuff devices, the BP value obtained in palmar flexion was significantly higher and that obtained in palmar

  4. Coupled Thermoelectric Devices: Theory and Experiment

    Directory of Open Access Journals (Sweden)

    Jaziel A. Rojas

    2016-07-01

    Full Text Available In this paper, we address theoretically and experimentally the optimization problem of the heat transfer occurring in two coupled thermoelectric devices. A simple experimental set up is used. The optimization parameters are the applied electric currents. When one thermoelectric is analysed, the temperature difference Δ T between the thermoelectric boundaries shows a parabolic profile with respect to the applied electric current. This behaviour agrees qualitatively with the corresponding experimental measurement. The global entropy generation shows a monotonous increase with the electric current. In the case of two coupled thermoelectric devices, elliptic isocontours for Δ T are obtained in applying an electric current through each of the thermoelectrics. The isocontours also fit well with measurements. Optimal figure of merit is found for a specific set of values of the applied electric currents. The entropy generation-thermal figure of merit relationship is studied. It is shown that, given a value of the thermal figure of merit, the device can be operated in a state of minimum entropy production.

  5. Oscillation experiments on Cesar and Marius - Experimental devices and measurement techniques

    International Nuclear Information System (INIS)

    Brunet, Max; Guerange, Jacques; Morier, Francis; Tonolli, Jacky

    1969-02-01

    An original method of measurement of effective cross sections of fissile materials has been developed by the CEA: a central fuel element of a critical experimental reactor is replaced by a sample containing the material to be studied. The replacement technique is based on oscillating the fuel load of the central channel. Signals are measured which are proportional to reactivity variation and to neutron density disturbance at the vicinity of the central channel, these variation and disturbance being produced by the sample oscillation. Measurements have been performed on experimental reactors (Minerve in Fontenay-aux-Roses, and Cesar and Marius in Cadarache). The authors herein describe the experimental devices and measurement techniques implemented in Marius and Cesar. In a first part, they describe the experimental devices which have been used during the three measurement campaigns (between 1965 and 1967). They report the study of measurement accuracies, and of some problems related to the use of the local detector [fr

  6. Electronic voltage and current transformers testing device.

    Science.gov (United States)

    Pan, Feng; Chen, Ruimin; Xiao, Yong; Sun, Weiming

    2012-01-01

    A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs) with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz). The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  7. Cloning of a quantum measurement

    International Nuclear Information System (INIS)

    Bisio, Alessandro; D'Ariano, Giacomo Mauro; Perinotti, Paolo; Sedlak, Michal

    2011-01-01

    We analyze quantum algorithms for cloning of a quantum measurement. Our aim is to mimic two uses of a device performing an unknown von Neumann measurement with a single use of the device. When the unknown device has to be used before the bipartite state to be measured is available we talk about 1→2 learning of the measurement, otherwise the task is called 1→2 cloning of a measurement. We perform the optimization for both learning and cloning for arbitrary dimension d of the Hilbert space. For 1→2 cloning we also propose a simple quantum network that achieves the optimal fidelity. The optimal fidelity for 1→2 learning just slightly outperforms the estimate and prepare strategy in which one first estimates the unknown measurement and depending on the result suitably prepares the duplicate.

  8. Cloning of a quantum measurement

    Energy Technology Data Exchange (ETDEWEB)

    Bisio, Alessandro; D' Ariano, Giacomo Mauro; Perinotti, Paolo; Sedlak, Michal [QUIT Group, Dipartimento di Fisica ' ' A. Volta' ' and INFN, via Bassi 6, I-27100 Pavia (Italy); QUIT Group, Dipartimento di Fisica ' ' A. Volta' ' via Bassi 6, I-27100 Pavia (Italy) and Institute of Physics, Slovak Academy of Sciences, Dubravska cesta 9, SK-845 11 Bratislava (Slovakia)

    2011-10-15

    We analyze quantum algorithms for cloning of a quantum measurement. Our aim is to mimic two uses of a device performing an unknown von Neumann measurement with a single use of the device. When the unknown device has to be used before the bipartite state to be measured is available we talk about 1{yields}2 learning of the measurement, otherwise the task is called 1{yields}2 cloning of a measurement. We perform the optimization for both learning and cloning for arbitrary dimension d of the Hilbert space. For 1{yields}2 cloning we also propose a simple quantum network that achieves the optimal fidelity. The optimal fidelity for 1{yields}2 learning just slightly outperforms the estimate and prepare strategy in which one first estimates the unknown measurement and depending on the result suitably prepares the duplicate.

  9. Device-Relaying in Cellular D2D Networks: A Fairness Perspective

    KAUST Repository

    Chaaban, Anas

    2015-10-24

    Device-to-Device (D2D) communication is envisioned to play a key role in 5G networks as a technique for meeting the demand for high data rates. In a cellular network, D2D allows not only direct communication between users, but also device relaying. In this paper, a simple instance of device-relaying is investigated, and its impact on fairness among users is studied. Namely, a cellular network consisting of two D2D-enabled users and a base-station (BS) is considered. Thus, the users who want to establish communication with the BS can act as relays for each other’s signals. While this problem is traditionally considered in the literature as a multiple-access channel with cooperation in the uplink, and a broadcast channel with cooperation in the downlink, we propose a different treatment of the problem as a multi-way channel. A simple communication scheme is proposed, and is shown to achieve significant gain in terms of fairness (measured by the symmetric rate supported) in comparison to the aforementioned traditional treatment.

  10. Device-Relaying in Cellular D2D Networks: A Fairness Perspective

    KAUST Repository

    Chaaban, Anas; Sezgin, Aydin

    2015-01-01

    Device-to-Device (D2D) communication is envisioned to play a key role in 5G networks as a technique for meeting the demand for high data rates. In a cellular network, D2D allows not only direct communication between users, but also device relaying. In this paper, a simple instance of device-relaying is investigated, and its impact on fairness among users is studied. Namely, a cellular network consisting of two D2D-enabled users and a base-station (BS) is considered. Thus, the users who want to establish communication with the BS can act as relays for each other’s signals. While this problem is traditionally considered in the literature as a multiple-access channel with cooperation in the uplink, and a broadcast channel with cooperation in the downlink, we propose a different treatment of the problem as a multi-way channel. A simple communication scheme is proposed, and is shown to achieve significant gain in terms of fairness (measured by the symmetric rate supported) in comparison to the aforementioned traditional treatment.

  11. Recommendations for blood pressure measuring devices for office/clinic use in low resource settings

    NARCIS (Netherlands)

    Parati, G.; Mendis, S.; Abegunde, D.; Asmar, R.; Mieke, S.; Murray, A.; Shengelia, B.; Steenvoorden, G.; Montfrans, G. van; O'Brien, E.

    2005-01-01

    This paper, which summarizes the conclusions of a WHO Expert meeting, is aimed at proposing indications to develop technical specifications for an accurate and affordable blood pressure measuring device for office/ clinic use in low resource settings. Blood pressure measuring devices to be used in

  12. Waveform measurement in mocrowave device characterization: impact on power amplifiers design

    Directory of Open Access Journals (Sweden)

    Roberto Quaglia

    2016-07-01

    Full Text Available This paper describes an example of a measurement setup enabling waveform measurements during the load-pull characterization of a microwave power device. The significance of this measurement feature is highlighted showing how waveform engineering can be exploited to design high efficiency microwave power amplifiers.

  13. On-line display used with cathode ray tube film measuring device

    International Nuclear Information System (INIS)

    Fortney, L.R.; Robertson, W.J.

    1981-01-01

    An improved display has been developed for use on our computer controlled measuring device (RIPPLE). The device features a television image of the film and a digital presentation on the same X, Y display. The television image is formed using a modified left and right raster scan which can cover 50% more area in the same time as the traditional raster

  14. Surface photovoltage measurements and finite element modeling of SAW devices.

    Energy Technology Data Exchange (ETDEWEB)

    Donnelly, Christine

    2012-03-01

    Over the course of a Summer 2011 internship with the MEMS department of Sandia National Laboratories, work was completed on two major projects. The first and main project of the summer involved taking surface photovoltage measurements for silicon samples, and using these measurements to determine surface recombination velocities and minority carrier diffusion lengths of the materials. The SPV method was used to fill gaps in the knowledge of material parameters that had not been determined successfully by other characterization methods. The second project involved creating a 2D finite element model of a surface acoustic wave device. A basic form of the model with the expected impedance response curve was completed, and the model is ready to be further developed for analysis of MEMS photonic resonator devices.

  15. Time-resolved triton burnup measurement using the scintillating fiber detector in the Large Helical Device

    Science.gov (United States)

    Ogawa, K.; Isobe, M.; Nishitani, T.; Murakami, S.; Seki, R.; Nakata, M.; Takada, E.; Kawase, H.; Pu, N.; LHD Experiment Group

    2018-03-01

    Time-resolved measurement of triton burnup is performed with a scintillating fiber detector system in the deuterium operation of the large helical device. The scintillating fiber detector system is composed of the detector head consisting of 109 scintillating fibers having a diameter of 1 mm and a length of 100 mm embedded in the aluminum substrate, the magnetic registrant photomultiplier tube, and the data acquisition system equipped with 1 GHz sampling rate analogies to digital converter and the field programmable gate array. The discrimination level of 150 mV was set to extract the pulse signal induced by 14 MeV neutrons according to the pulse height spectra obtained in the experiment. The decay time of 14 MeV neutron emission rate after neutral beam is turned off measured by the scintillating fiber detector. The decay time is consistent with the decay time of total neutron emission rate corresponding to the 14 MeV neutrons measured by the neutron flux monitor as expected. Evaluation of the diffusion coefficient is conducted using a simple classical slowing-down model FBURN code. It is found that the diffusion coefficient of triton is evaluated to be less than 0.2 m2 s-1.

  16. A fast and simple approach for the estimation of a radiological source from localised measurements after the explosion of a radiological dispersal device

    International Nuclear Information System (INIS)

    Urso, L.; Kaiser, J.C.; Woda, C.; Helebrant, J.; Hulka, J.; Kuca, P.; Prouza, Z.

    2014-01-01

    After an explosion of a radiological dispersal device, decision-makers need to implement countermeasures as soon as possible to minimise the radiation-induced risks to the population. In this work, the authors present a tool, which can help providing information about the approximate size of source term and radioactive contamination based on a Gaussian Plume model with the use of available measurements for liquid or aerosolised radioactivity. For two-field tests, the source term and spatial distribution of deposited radioactivity are estimated. A sensitivity analysis of the dependence on deposition velocity is carried out. In case of weak winds, a diffusive process along the wind direction is retained in the model. (authors)

  17. Small angle neutron scattering study of metallic alloys by a double crystal device

    International Nuclear Information System (INIS)

    Cser, L.; Kovacs, I.; Kroo, N.; Zsigmond, Gy.

    1982-06-01

    A double crystal small angle neutron scattering (SANS) device was built and a simple method for measuring the integrated SANS intensity was developed. The device and the method were tested and the possibility of future applications was demonstrated by measurements on different samples. The test measurements were performed on iron and teflon slabs of different thickness. On Fe-B metallic glasses a SANS intensity originating mainly from the multiple magnetic refraction at domain boundaries was observed. A very weak SANS intensity was found on turbine blades. The integrated SANS intensity was shown to correlate with the running time of the blades. Similar measurements were performed on artificially deformed steel samples. (author)

  18. Simple Harmonics Motion experiment based on LabVIEW interface for Arduino

    Science.gov (United States)

    Tong-on, Anusorn; Saphet, Parinya; Thepnurat, Meechai

    2017-09-01

    In this work, we developed an affordable modern innovative physics lab apparatus. The ultrasonic sensor is used to measure the position of a mass attached on a spring as a function of time. The data acquisition system and control device were developed based on LabVIEW interface for Arduino UNO R3. The experiment was designed to explain wave propagation which is modeled by simple harmonic motion. The simple harmonic system (mass and spring) was observed and the motion can be realized using curve fitting to the wave equation in Mathematica. We found that the spring constants provided by Hooke’s law and the wave equation fit are 9.9402 and 9.1706 N/m, respectively.

  19. Simultaneous 3D-vibration measurement using a single laser beam device

    Science.gov (United States)

    Brecher, Christian; Guralnik, Alexander; Baümler, Stephan

    2012-06-01

    Today's commercial solutions for vibration measurement and modal analysis are 3D-scanning laser doppler vibrometers, mainly used for open surfaces in the automotive and aerospace industries and the classic three-axial accelerometers in civil engineering, for most industrial applications in manufacturing environments, and particularly for partially closed structures. This paper presents a novel measurement approach using a single laser beam device and optical reflectors to simultaneously perform 3D-dynamic measurement as well as geometry measurement of the investigated object. We show the application of this so called laser tracker for modal testing of structures on a mechanical manufacturing shop floor. A holistic measurement method is developed containing manual reflector placement, semi-automated geometric modeling of investigated objects and fully automated vibration measurement up to 1000 Hz and down to few microns amplitude. Additionally the fast set up dynamic measurement of moving objects using a tracking technique is presented that only uses the device's own functionalities and does neither require a predefined moving path of the target nor an electronic synchronization to the moving object.

  20. 77 FR 35745 - Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in...

    Science.gov (United States)

    2012-06-14

    ..., battery powered device with a semiconductor sensor. (2) Alcohol Countermeasure Systems Corp., submitted...-0062] Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in... Screening Devices to Measure Alcohol in Bodily Fluids dated, March 31, 2008 (73 FR 16956). DATES: Effective...

  1. Design and Functional Validation of a Complex Impedance Measurement Device for Characterization of Ultrasonic Transducers

    International Nuclear Information System (INIS)

    De-Cock, Wouter; Cools, Jan; Leroux, Paul

    2013-06-01

    This paper presents the design and practical implementation of a complex impedance measurement device capable of characterization of ultrasonic transducers. The device works in the frequency range used by industrial ultrasonic transducers which is below the measurement range of modern high end network analyzers. The device uses the Goertzel algorithm instead of the more common FFT algorithm to calculate the magnitude and phase component of the impedance under test. A theoretical overview is given followed by a practical approach and measurement results. (authors)

  2. Cross-Device Tracking: Measurement and Disclosures

    Directory of Open Access Journals (Sweden)

    Brookman Justin

    2017-04-01

    Full Text Available Internet advertising and analytics technology companies are increasingly trying to find ways to link behavior across the various devices consumers own. This cross-device tracking can provide a more complete view into a consumer’s behavior and can be valuable for a range of purposes, including ad targeting, research, and conversion attribution. However, consumers may not be aware of how and how often their behavior is tracked across different devices. We designed this study to try to assess what information about cross-device tracking (including data flows and policy disclosures is observable from the perspective of the end user. Our paper demonstrates how data that is routinely collected and shared online could be used by online third parties to track consumers across devices.

  3. Microwave produced plasma in a Toroidal Device

    Science.gov (United States)

    Singh, A. K.; Edwards, W. F.; Held, E. D.

    2010-11-01

    A currentless toroidal plasma device exhibits a large range of interesting basic plasma physics phenomena. Such a device is not in equilibrium in a strict magneto hydrodynamic sense. There are many sources of free energy in the form of gradients in plasma density, temperature, the background magnetic field and the curvature of the magnetic field. These free energy sources excite waves and instabilities which have been the focus of studies in several devices in last two decades. A full understanding of these simple plasmas is far from complete. At Utah State University we have recently designed and installed a microwave plasma generation system on a small tokamak borrowed from the University of Saskatchewan, Saskatoon, Canada. Microwaves are generated at 2.45 GHz in a pulsed dc mode using a magnetron from a commercial kitchen microwave oven. The device is equipped with horizontal and vertical magnetic fields and a transformer to impose a toroidal electric field for current drive. Plasmas can be obtained over a wide range of pressure with and without magnetic fields. We present some preliminary measurements of plasma density and potential profiles. Measurements of plasma temperature at different operating conditions are also presented.

  4. Spring-action Apparatus for Fixation of Eyeball (SAFE): a novel, cost-effective yet simple device for ophthalmic wet-lab training.

    Science.gov (United States)

    Ramakrishnan, Seema; Baskaran, Prabu; Fazal, Romana; Sulaiman, Syed Mohammad; Krishnan, Tiruvengada; Venkatesh, Rengaraj

    2016-10-01

    Achieving a formed and firm eyeball which is stably fixed in a holding device is a major challenge of surgical wet-lab training. Our innovation, the 'Spring-action Apparatus for Fixation of Eyeball (SAFE)' is a robust, simple and economical device to solve this problem. It consists of a hollow iron cylinder to which a spring-action syringe is attached. The spring-action syringe generates vacuum and enables reliable fixation of a human or animal cadaveric eye on the iron cylinder. The rise in intraocular pressure due to vacuum fixation can be varied as per need or nature of surgery being practised. A mask-fixed version of this device is also designed to train surgeons for appropriate hand positioning. An experienced surgeon performed various surgeries including manual small incision cataract surgery (MSICS), phacoemulsification, laser in situ keratomileusis (LASIK), femtosecond LASIK docking, Descemet's stripping endothelial keratoplasty, deep anterior lamellar keratoplasty, penetrating keratoplasty and trabeculectomy on this device, while a trainee surgeon practised MSICS and wound suturing. Skill-appropriate comfort level was much higher with SAFE than with conventional globe holders for both surgeons. Due to its stability, pressure adjustability, portability, cost-efficiency and simplicity, we recommend SAFE as the basic equipment for every wet lab. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  5. An industrial radiography exposure device based on measurement of transmitted gamma-ray intensity

    International Nuclear Information System (INIS)

    Polee, C; Chankow, N; Srisatit, S; Thong-Aram, D

    2015-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking information of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a small detector. Application software was developed for Android mobile phone to remotely control the device and to display counting data via Bluetooth communication. Prior to film exposure, the device is placed behind a specimen to measure transmitted intensity which is inversely proportional to the exposure. Unlike in using the conventional exposure curve, correction factors for source decay, source-to- film distance, specimen thickness and kind of material are not needed. The developed technique and device make radiographic process economic, convenient and more reliable. (paper)

  6. Implantable optogenetic device with CMOS IC technology for simultaneous optical measurement and stimulation

    Science.gov (United States)

    Haruta, Makito; Kamiyama, Naoya; Nakajima, Shun; Motoyama, Mayumi; Kawahara, Mamiko; Ohta, Yasumi; Yamasaki, Atsushi; Takehara, Hiroaki; Noda, Toshihiko; Sasagawa, Kiyotaka; Ishikawa, Yasuyuki; Tokuda, Takashi; Hashimoto, Hitoshi; Ohta, Jun

    2017-05-01

    In this study, we have developed an implantable optogenetic device that can measure and stimulate neurons by an optical method based on CMOS IC technology. The device consist of a blue LED array for optically patterned stimulation, a CMOS image sensor for acquiring brain surface image, and eight green LEDs surrounding the CMOS image sensor for illumination. The blue LED array is placed on the CMOS image sensor. We implanted the device in the brain of a genetically modified mouse and successfully demonstrated the stimulation of neurons optically and simultaneously acquire intrinsic optical images of the brain surface using the image sensor. The integrated device can be used for simultaneously measuring and controlling neuronal activities in a living animal, which is important for the artificial control of brain functions.

  7. Underwater radiation measuring device

    International Nuclear Information System (INIS)

    Seki, Noriyuki; Suzuki, Yasuo

    1998-01-01

    The present invention provides a device for measuring, under water, radiation from spent fuels (long members to be detected) of nuclear power plants and reprocessing facilities. Namely, a detecting insertion tube (insertion tube) is disposed so as to be in parallel with axial direction of the long member to be detected stored underwater. A γ-ray detector is inserted to the inside of the insertion tube. A driving mechanism is disposed for moving the γ-ray detector in axial direction inside of the insertion tube. The driving mechanism preferably has a system that it moves the γ-ray detector by winding a detection signal cable around a driving drum. The driving mechanism is formed by inserting and securing a driving tube having screws formed on the side surface and inserting it into the insertion tube. It may have a system of moving the γ-ray detector together with the driving tube while engaging the teeth of a driving transfer mechanism with the screws of the driving tube. (I.S.)

  8. Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices.

    Science.gov (United States)

    Pejović, Milić M; Denić, Dragan B; Pejović, Momčilo M; Nešić, Nikola T; Vasović, Nikola

    2010-10-01

    This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

  9. Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

    Energy Technology Data Exchange (ETDEWEB)

    Pejovic, Milic M.; Denic, Dragan B.; Pejovic, Momcilo M.; Nesic, Nikola T.; Vasovic, Nikola [Faculty of Electronic Engineering, University of Nis, Aleksandra Medvedeva 14, 18000 Nis (Serbia)

    2010-10-15

    This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

  10. Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices

    International Nuclear Information System (INIS)

    Pejovic, Milic M.; Denic, Dragan B.; Pejovic, Momcilo M.; Nesic, Nikola T.; Vasovic, Nikola

    2010-01-01

    This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.

  11. Device for the integral measurement of ionizing radiations

    International Nuclear Information System (INIS)

    Micheron, Francois.

    1980-01-01

    This invention relates to devices for the integral determination of ionizing radiations, particularly to the construction of a portable dosemeter. Portable measuring instruments have been suggested in the past, particularly dosemeters in which the discharge of a capacitor under the action of ionizing radiations is measured. Since the charge of a capacitor is not stable owing to dielectric imperfections, these measuring instruments have to be recalibrated at frequent intervals. To overcome this drawback, the invention suggests using the discharge of an electret, electrically charged to a pre-set initial value, under the action of ionizing radiations, as the transducer means of a dosemeter used in conjunction with display or warning systems [fr

  12. Measurement of whole tire profile

    Science.gov (United States)

    Yang, Yongyue; Jiao, Wenguang

    2010-08-01

    In this paper, a precision measuring device is developed for obtaining characteristic curve of tire profile and its geometric parameters. It consists of a laser displacement measurement unit, a closed-loop precision two-dimensional coordinate table, a step motor control system and a fast data acquisition and analysis system. Based on the laser trigonometry, a data map of tire profile and coordinate values of all points can be obtained through corresponding data transformation. This device has a compact structure, a convenient control, a simple hardware circuit design and a high measurement precision. Experimental results indicate that measurement precision can meet the customer accuracy requirement of +/-0.02 mm.

  13. Simple Coatings to Render Polystyrene Protein Resistant

    Directory of Open Access Journals (Sweden)

    Marcelle Hecker

    2018-02-01

    Full Text Available Non-specific protein adsorption is detrimental to the performance of many biomedical devices. Polystyrene is a commonly used material in devices and thin films. Simple reliable surface modification of polystyrene to render it protein resistant is desired in particular for device fabrication and orthogonal functionalisation schemes. This report details modifications carried out on a polystyrene surface to prevent protein adsorption. The trialed surfaces included Pluronic F127 and PLL-g-PEG, adsorbed on polystyrene, using a polydopamine-assisted approach. Quartz crystal microbalance with dissipation (QCM-D results showed only short-term anti-fouling success of the polystyrene surface modified with F127, and the subsequent failure of the polydopamine intermediary layer in improving its stability. In stark contrast, QCM-D analysis proved the success of the polydopamine assisted PLL-g-PEG coating in preventing bovine serum albumin adsorption. This modified surface is equally as protein-rejecting after 24 h in buffer, and thus a promising simple coating for long term protein rejection of polystyrene.

  14. Characterization of simple wireless neurostimulators and sensors.

    Science.gov (United States)

    Gulick, Daniel W; Towe, Bruce C

    2014-01-01

    A single diode with a wireless power source and electrodes can act as an implantable stimulator or sensor. We have built such devices using RF and ultrasound power coupling. These simple devices could drastically reduce the size, weight, and cost of implants for applications where efficiency is not critical. However, a shortcoming has been a lack of control: any movement of the external power source would change the power coupling, thereby changing the stimulation current or modulating the sensor response. To correct for changes in power and signal coupling, we propose to use harmonic signals from the device. The diode acts as a frequency multiplier, and the harmonics it emits contain information about the drive level and bias. A simplified model suggests that estimation of power, electrode bias, and electrode resistance is possible from information contained in radiated harmonics even in the presence of significant noise. We also built a simple RF-powered stimulator with an onboard voltage limiter.

  15. Measuring device for water quality at reactor bottom

    Energy Technology Data Exchange (ETDEWEB)

    Urata, Hidehiro; Takagi, Jun-ichi

    1995-10-27

    The present invention concerns measurement for water quality at the bottom of a reactor of a BWR type plant, in which reactor water is sampled and analyzed in a state approximate to conditions in a pressure vessel. Based on the result, hydrogen injection amount is controlled during hydrogen injection operation. Namely, a monitor for water quality is disposed to a sampling line in communication with the bottom of a pressure vessel. A water quality monitor is disposed to a drain sampling line in communication with the bottom of the pressure vessel. A corrosion potentiometer is disposed to the pressure sampling line or the drain sampling line. A dissolved oxygen measuring device is disposed to the pressure vessel sampling line or the drain sampling line. With such a constitution, the reactor water can be sampled and analyzed in a state approximate to the conditions in the pressure vessel. In addition, signals from the water quality monitor are inputted to a hydrogen injection amount control device. As a result, the amount of hydrogen injected to primary coolants can be controlled in a state approximate to the conditions in the pressure vessel. (I.S.).

  16. Measuring device for water quality at reactor bottom

    International Nuclear Information System (INIS)

    Urata, Hidehiro; Takagi, Jun-ichi.

    1995-01-01

    The present invention concerns measurement for water quality at the bottom of a reactor of a BWR type plant, in which reactor water is sampled and analyzed in a state approximate to conditions in a pressure vessel. Based on the result, hydrogen injection amount is controlled during hydrogen injection operation. Namely, a monitor for water quality is disposed to a sampling line in communication with the bottom of a pressure vessel. A water quality monitor is disposed to a drain sampling line in communication with the bottom of the pressure vessel. A corrosion potentiometer is disposed to the pressure sampling line or the drain sampling line. A dissolved oxygen measuring device is disposed to the pressure vessel sampling line or the drain sampling line. With such a constitution, the reactor water can be sampled and analyzed in a state approximate to the conditions in the pressure vessel. In addition, signals from the water quality monitor are inputted to a hydrogen injection amount control device. As a result, the amount of hydrogen injected to primary coolants can be controlled in a state approximate to the conditions in the pressure vessel. (I.S.)

  17. Simple solution-processed CuOX as anode buffer layer for efficient organic solar cells

    International Nuclear Information System (INIS)

    Shen, Wenfei; Yang, Chunpeng; Bao, Xichang; Sun, Liang; Wang, Ning; Tang, Jianguo; Chen, Weichao; Yang, Renqiang

    2015-01-01

    Graphical abstract: - Highlights: • Simple solution-processed CuO X hole transport layer for efficient organic solar cell. • Good photovoltaic performances as hole transport layer in OSCs with P3HT and PBDTTT-C as donor materials. • The device with CuO X as hole transport layer shows great improved stability compared with that of device with PEDOT:PSS as hole transport layer. - Abstract: A simple, solution-processed ultrathin CuO X anode buffer layer was fabricated for high performance organic solar cells (OSCs). XPS measurement demonstrated that the CuO X was the composite of CuO and Cu 2 O. The CuO X modified ITO glass exhibit a better surface contact with the active layer. The photovoltaic performance of the devices with CuO X layer was optimized by varying the thickness of CuO X films through changing solution concentration. With P3HT:PC 61 BM as the active layer, we demonstrated an enhanced PCE of 4.14% with CuO X anode buffer layer, compared with that of PEDOT:PSS layer. The CuO X layer also exhibits efficient photovoltaic performance in devices with PBDTTT-C:PC 71 BM as the active layer. The long-term stability of CuO X device is better than that of PEDOT:PSS device. The results indicate that the easy solution-processed CuO X film can act as an efficient anode buffer layer for high-efficiency OSCs

  18. An investigation of highly accurate and precise robotic hole measurements using non-contact devices

    Directory of Open Access Journals (Sweden)

    Usman Zahid

    2016-01-01

    Full Text Available Industrial robots arms are widely used in manufacturing industry because of their support for automation. However, in metrology, robots have had limited application due to their insufficient accuracy. Even using error compensation and calibration methods, robots are not effective for micrometre (μm level metrology. Non-contact measurement devices can potentially enable the use of robots for highly accurate metrology. However, the use of such devices on robots has not been investigated. The research work reported in this paper explores the use of different non-contact measurement devices on an industrial robot. The aim is to experimentally investigate the effects of robot movements on the accuracy and precision of measurements. The focus has been on assessing the ability to accurately measure various geometric and surface parameters of holes despite the inherent inaccuracies of industrial robot. This involves the measurement of diameter, roundness and surface roughness. The study also includes scanning of holes for measuring internal features such as start and end point of a taper. Two different non-contact measurement devices based on different technologies are investigated. Furthermore, effects of eccentricity, vibrations and thermal variations are also assessed. The research contributes towards the use of robots for highly accurate and precise robotic metrology.

  19. Comparison of the methods for determination of calibration and verification intervals of measuring devices

    Directory of Open Access Journals (Sweden)

    Toteva Pavlina

    2017-01-01

    Full Text Available The paper presents different determination and optimisation methods for verification intervals of technical devices for monitoring and measurement based on the requirements of some widely used international standards, e.g. ISO 9001, ISO/IEC 17020, ISO/IEC 17025 etc., maintained by various organizations implementing measuring devices in practice. Comparative analysis of the reviewed methods is conducted in terms of opportunities for assessing the adequacy of interval(s for calibration of measuring devices and their optimisation accepted by an organization – an extension or reduction depending on the obtained results. The advantages and disadvantages of the reviewed methods are discussed, and recommendations for their applicability are provided.

  20. The transient electric field measurement system for EAST device

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y., E-mail: wayong@ipp.ac.cn [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Ji, Z.S. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China); Zhu, C.M. [The Experiment & Verification Center of State Grid Electric Power Research Institute (The Automation Equipment EMC Lab. of State Grid Co.), Nanjing, Jiangsu (China); Zhang, Z.C.; Ma, T.F.; Xu, Z.H. [Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui (China)

    2016-11-15

    The electromagnetic environment around the Experimental Advanced Superconducting Tokamak (EAST) device is very complex during plasma discharge experiment. In order to fully monitor the changes of electric field around the EAST device during plasma discharge, a transient electric field measurement system based on PCI eXtensions for Instrumentation (PXI) platform has been designed. A digitizer is used for high-speed data acquisition of raw signals from electric field sensors, and a Field Programmable Gate Array (FPGA) module is used for realizing an on-the-fly fast Fourier transform (FFT) and inverse fast Fourier transform (IFFT) algorithm including a beforehand identified antenna factor (AF) to achieve finally a calibrated and filtered electric field measurement, then these signals can be displayed and easily analyzed. The raw signals from electric field sensors are transferred through optical fiber by optical isolation to reduce electromagnetic interference (EMI). The high speed data streaming technology is used for data storage. A prototype of this system has been realized to measure the transient electric field strength, with the real-time processing and continuous acquisition ability of one channel of 14-bit resolution and up to 50 MHz sampling rate, and 6 KHz FFT frequency resolution.

  1. 40 CFR 63.9525 - What are the installation, operation, and maintenance requirements for my weight measurement device?

    Science.gov (United States)

    2010-07-01

    ... measurement device? (a) If you use a solvent recovery system, you must install, operate, and maintain a weight... solvent mixer. If the weight measurement device cannot reproduce the value of the calibration weight..., and maintenance requirements for my weight measurement device? 63.9525 Section 63.9525 Protection of...

  2. Inter-device reliability of an automatic-scoring actigraph for measuring sleep in healthy adults

    Directory of Open Access Journals (Sweden)

    Matthew Driller

    2016-07-01

    Full Text Available Actigraphy has become a common method of measuring sleep due to its non-invasive, cost-effective nature. An actigraph (Readiband™ that utilizes automatic scoring algorithms has been used in the research, but is yet to be evaluated for its inter-device reliability. A total of 77 nights of sleep data from 11 healthy adult participants was collected while participants were concomitantly wearing two Readiband™ actigraphs attached together (ACT1 and ACT2. Sleep indices including total sleep time (TST, sleep latency (SL, sleep efficiency (SE%, wake after sleep onset (WASO, total time in bed (TTB, wake episodes per night (WE, sleep onset variance (SOV and wake variance (WV were assessed between the two devices using mean differences, 95% levels of agreement, intraclass correlation coefficients (ICC, typical error of measurement (TEM and coefficient of variation (CV% analysis. There were no significant differences between devices for any of the measured sleep variables (p>0.05. TST, SE, SL, TTB, SOV and WV all resulted in very high ICC's (>0.90, with WASO and WE resulting in high ICC's between devices (0.85 and 0.80, respectively. Mean differences of −2.1 and 0.2 min for TST and SL were associated with a low TEM between devices (9.5 and 3.8 min, respectively. SE resulted in a 0.3% mean difference between devices. The Readiband™ is a reliable tool for researchers using multiple devices of this brand in sleep studies to assess basic measures of sleep quality and quantity in healthy adult populations.

  3. Measurement of Retinal Sensitivity on Tablet Devices in Age-Related Macular Degeneration.

    Science.gov (United States)

    Wu, Zhichao; Guymer, Robyn H; Jung, Chang J; Goh, Jonathan K; Ayton, Lauren N; Luu, Chi D; Lawson, David J; Turpin, Andrew; McKendrick, Allison M

    2015-06-01

    We compared measurements of central retinal sensitivity on a portable, low-cost tablet device to the established method of microperimetry in age-related macular degeneration (AMD). A customized test designed to measure central retinal sensitivity (within the central 1° radius) on a tablet device was developed using an open-source platform called PsyPad. A total of 30 participants with AMD were included in this study, and all participants performed a practice test on PsyPad, followed by four tests of one eye and one test of the other eye. Participants then underwent standardized microperimetry examinations in both eyes. The average test duration on PsyPad was 53.9 ± 7.5 seconds, and no significant learning effect was observed over the examinations performed ( P = 1.000). The coefficient of repeatability of central retinal sensitivity between the first two examinations on PsyPad was ±1.76 dB. The mean central retinal sensitivity was not significantly different between PsyPad (25.7 ± 0.4 dB) and microperimetry (26.1 ± 0.4 dB, P = 0.094), and the 95% limits of agreement between the two measures were between -4.12 and 4.92 dB. The measurements of central retinal sensitivity can be performed effectively using a tablet device, displaying reasonably good agreement with those obtained using the established method of microperimetry. These findings highlight the potential of tablet devices as low-cost and portable tools for developing and performing visual function measures that can be easily and widely implemented.

  4. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children

    Directory of Open Access Journals (Sweden)

    Janson C

    2006-04-01

    Full Text Available Abstract Background Exhaled nitric oxide (NO measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO was compared with a standard stationary chemiluminescence unit (NIOX. Methods A total of 71 subjects (6–60 years; 36 males, both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots, measurement feasibility (success rate with 6 attempts and repeatability (intrasubject SD. Results Success rate was high (≥ 84% in both devices for both adults and children. The subjects represented a FENO range of 8–147 parts per billion (ppb. When comparing the mean of three measurements (n = 61, the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. Conclusion The hand-held device (NIOX MINO and the stationary system (NIOX are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO is used. The hand-held device shows good repeatability, and it

  5. Performance of a new hand-held device for exhaled nitric oxide measurement in adults and children.

    Science.gov (United States)

    Alving, K; Janson, C; Nordvall, L

    2006-04-20

    Exhaled nitric oxide (NO) measurement has been shown to be a valuable tool in the management of patients with asthma. Up to now, most measurements have been done with stationary, chemiluminescence-based NO analysers, which are not suitable for the primary health care setting. A hand-held NO analyser which simplifies the measurement would be of value both in specialized and primary health care. In this study, the performance of a new electrochemical hand-held device for exhaled NO measurements (NIOX MINO) was compared with a standard stationary chemiluminescence unit (NIOX). A total of 71 subjects (6-60 years; 36 males), both healthy controls and atopic patients with and without asthma were included. The mean of three approved exhalations (50 ml/s) in each device, and the first approved measurement in the hand-held device, were compared with regard to NO readings (Bland-Altman plots), measurement feasibility (success rate with 6 attempts) and repeatability (intrasubject SD). Success rate was high (> or = 84%) in both devices for both adults and children. The subjects represented a FENO range of 8-147 parts per billion (ppb). When comparing the mean of three measurements (n = 61), the median of the intrasubject difference in exhaled NO for the two devices was -1.2 ppb; thus generally the hand-held device gave slightly higher readings. The Bland-Altman plot shows that the 95% limits of agreement were -9.8 and 8.0 ppb. The intrasubject median difference between the NIOX and the first approved measurement in the NIOX MINO was -2.0 ppb, and limits of agreement were -13.2 and 10.2 ppb. The median repeatability for NIOX and NIOX MINO were 1.1 and 1.2 ppb, respectively. The hand-held device (NIOX MINO) and the stationary system (NIOX) are in clinically acceptable agreement both when the mean of three measurements and the first approved measurement (NIOX MINO) is used. The hand-held device shows good repeatability, and it can be used successfully on adults and most children

  6. Device for measuring the exposure time in dental X-ray - Cronox

    International Nuclear Information System (INIS)

    Menezes, Claudio J.M.; Santos, Luiz A.P. dos

    2009-01-01

    The Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE) developed a test device for monitoring the X-ray beam in dental equipment to its application in quality control programs. This device, called Odontologic Dosimetric Card (CDO of Cartao Dosimetrico Odontologico in Portuguese) uses thermoluminescent dosimeters (TLD) for the measurement of some parameters of the X-ray beam as the entrance surface dose, the peak tension and half value layer (HVL). Radiographic films record the size of the radiation field. However, the TLD does not allow the assessment of exposure time, a parameter that complements the requirements of the Diretrizes de Protecao Radiologica em Radiodiagnostico Medico e Odontologico of Department of Health in Brazil for such equipment. Thus was developed a system based on sensitivity to ionizing radiation of phototransistors for measurement of exposure time when a patient is put in a clinical dental radiography. The system, called CRONOX was sized to be inserted within the CDO. The results showed that the measuring error had developed for less than 3% when compared to reference values obtained with the Tektronix digital oscilloscope, TDS2022 model. The readings obtained with the CRONOX were also compared with the nominal values selected in the X-ray equipment and with the values measured with the instrument of trade PTW Diavolt Universal. The results showed that the measuring device developed showed a maximum deviation of 5.92% on the nominal value selected, while for the instrument of PTW was 17.86%. (author)

  7. Speckle interferometry application for erosion measurements in fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Gauthier, E.; Roupillard, R. [Association Euratom-CEA Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee

    2003-07-01

    In order to measure erosion/redeposition in fusion devices, a new diagnostic based on speckle interferometry is investigated. First experiments performed on carbon fibre composite (CFC) materials have shown that this technique is able to measure a modification of the surface in the range of 1 {mu}m. Further experiments have been performed on different materials using a second wavelength in order to carry out 3-dimensional measurements of the surface and to increase the dynamic range of the depth measurement. A diagnostic, based on two-wavelength TV-holography to measure in situ erosion/redeposition during long duration discharges on the CIEL limiter in Tore Supra, is under development at CEA Cadarache. (authors)

  8. A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study.

    Science.gov (United States)

    Schoot, Tessa S; Weenk, Mariska; van de Belt, Tom H; Engelen, Lucien J L P G; van Goor, Harry; Bredie, Sebastian J H

    2016-05-05

    Cuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP self-measurement. The objective of our study was to evaluate the performance of the first release of the Checkme Health Monitor (Viatom Technology), a cuffless BP monitor, in a real-life setting. Furthermore, we wanted to investigate whether the posture of the volunteer and the position of the device relative to the heart level would influence its outcomes. Study volunteers fell into 3 BP ranges: high (>160 mmHg), normal (130-160 mmHg), and low (measurements were met according to the European Society of Hypertension International Protocol (ESH-IP) for the validation of BP measurement devices. After calibrating the Checkme device, we measured systolic BP with Checkme and a validated, oscillometric reference BP monitor (RM). Measurements were performed in randomized order both in supine and in sitting position, and with Checkme at and above heart level. We recruited 52 volunteers, of whom we excluded 15 (12 due to calibration failure with Checkme, 3 due to a variety of reasons). The remaining 37 volunteers were divided into low (n=14), medium (n=13), and high (n=10) BP ranges. There were 18 men and 19 women, with a mean age of 54.1 (SD 14.5) years, and mean recruitment systolic BP of 141.7 (SD 24.7) mmHg. BP results obtained by RM and Checkme correlated well. In the supine position, the difference between the RM and Checkme was >5 mmHg in 17 of 37 volunteers (46%), of whom 9 of 37 (24%) had a difference >10 mmHg and 5 of 37 (14%) had a difference >15 mmHg. BP obtained with Checkme correlated well with RM BP, particularly in the position (supine) in which the device was calibrated. These preliminary results are promising for conducting further research on cuffless BP measurement in the

  9. Measurement-Device-Independent Quantum Cryptography

    Science.gov (United States)

    Tang, Zhiyuan

    Quantum key distribution (QKD) enables two legitimate parties to share a secret key even in the presence of an eavesdropper. The unconditional security of QKD is based on the fundamental laws of quantum physics. Original security proofs of QKD are based on a few assumptions, e.g., perfect single photon sources and perfect single-photon detectors. However, practical implementations of QKD systems do not fully comply with such assumptions due to technical limitations. The gap between theory and implementations leads to security loopholes in most QKD systems, and several attacks have been launched on sophisticated QKD systems. Particularly, the detectors have been found to be the most vulnerable part of QKD. Much effort has been put to build side-channel-free QKD systems. Solutions such as security patches and device-independent QKD have been proposed. However, the former are normally ad-hoc, and cannot close unidentified loopholes. The latter, while having the advantages of removing all assumptions on devices, is impractical to implement today. Measurement-device-independent QKD (MDI-QKD) turns out to be a promising solution to the security problem of QKD. In MDI-QKD, all security loopholes, including those yet-to-be discovered, have been removed from the detectors, the most critical part in QKD. In this thesis, we investigate issues related to the practical implementation and security of MDI-QKD. We first present a demonstration of polarization-encoding MDI-QKD. Taking finite key effect into account, we achieve a secret key rate of 0.005 bit per second (bps) over 10 km spooled telecom fiber, and a 1600-bit key is distributed. This work, together with other demonstrations, shows the practicality of MDI-QKD. Next we investigate a critical assumption of MDI-QKD: perfect state preparation. We apply the loss-tolerant QKD protocol and adapt it to MDI-QKD to quantify information leakage due to imperfect state preparation. We then present an experimental demonstration of

  10. Microfluidic device for cell capture and impedance measurement.

    Science.gov (United States)

    Jang, Ling-Sheng; Wang, Min-How

    2007-10-01

    This work presents a microfluidic device to capture physically single cells within microstructures inside a channel and to measure the impedance of a single HeLa cell (human cervical epithelioid carcinoma) using impedance spectroscopy. The device includes a glass substrate with electrodes and a PDMS channel with micro pillars. The commercial software CFD-ACE+ is used to study the flow of the microstructures in the channel. According to simulation results, the probability of cell capture by three micro pillars is about 10%. An equivalent circuit model of the device is established and fits closely to the experimental results. The circuit can be modeled electrically as cell impedance in parallel with dielectric capacitance and in series with a pair of electrode resistors. The system is operated at low frequency between 1 and 100 kHz. In this study, experiments show that the HeLa cell is successfully captured by the micro pillars and its impedance is measured by impedance spectroscopy. The magnitude of the HeLa cell impedance declines at all operation voltages with frequency because the HeLa cell is capacitive. Additionally, increasing the operation voltage reduces the magnitude of the HeLa cell because a strong electric field may promote the exchange of ions between the cytoplasm and the isotonic solution. Below an operating voltage of 0.9 V, the system impedance response is characteristic of a parallel circuit at under 30 kHz and of a series circuit at between 30 and 100 kHz. The phase of the HeLa cell impedance is characteristic of a series circuit when the operation voltage exceeds 0.8 V because the cell impedance becomes significant.

  11. Measuring the energy consumption of single-phase UPS-devices; Energiemessungen von 1-phasigen USV-Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    Bush, E. [Bush Energie GmbH, Felsberg (Switzerland); Schalcher, M.; Bruggmann, T.; Kuehne, P.; Kammermann, S. [Hochschule fuer Technik und Wirtschaft Chur, Chur (Switzerland)

    2007-11-15

    In the present measuring project, 46 single-phase uninterruptible power supplies (UPS-devices) in the power range from 350 VA up to 3000 VA could be measured with regard to efficiency and energy consumption, at Testlabor S.A.L.T., Chur, Switzerland. The classification into VFD-, VI- and VFI-devices as well as the carrying out of the measuring was accomplished in compliance with IEC 62040-3 with resistive and nonlinear load. As expected, the VFD-devices showed the best efficiency level, followed by VI- and VFI-devices. The efficiency rate at 50%, 75% and 100% of the nominal power differs only slightly and in most cases exceeds 90%. However, at a load of 25% the efficiency decreases considerably (in individual cases to below 80%). There are large differences in the area of standby losses (switched on, without load) which can only partly be explained by the different technologies of the various types of UPS-devices. Compared to the Code of Conduct for UPS-devices with a power of more than 10 kVA, the devices with lower power compare relatively well, especially because of the small power demands for cooling. (author)

  12. The insertion device magnetic measurement facility: Prototype and operational procedures

    International Nuclear Information System (INIS)

    Burkel, L.; Dejus, R.; Maines, J.; O'Brien, J.; Vasserman, I.; Pfleuger, J.

    1993-03-01

    This report is a description of the current status of the magnetic measurement facility and is a basic instructional manual for the operation of the facility and its components. Please refer to the appendices for more detailed information about specific components and procedures. The purpose of the magnetic measurement facility is to take accurate measurements of the magnetic field in the gay of the IDs in order to determine the effect of the ID on the stored particle beam and the emitted radiation. The facility will also play an important role when evaluating new ideas, novel devices, and inhouse prototypes as part of the ongoing research and development program at the APS. The measurements will be performed with both moving search coils and moving Hall probes. The IDs will be evaluated by computer modeling of the emitted radiation for any given (measured) magnetic field map. The quality of the magnetic field will be described in terms of integrated multipoles for the effect on Storage Ring performance and in terms of the derived trajectories for the emitted radiation. Before being installed on the Storage Ring, every device will be measured and characterized to assure that it is compatible with Storage Ring requirements and radiation specifications. The accuracy that the APS needs to achieve for magnetic measurements will be based on these specifications

  13. Measuring device and method for dimples height differences of 17 x 17 grid

    International Nuclear Information System (INIS)

    Xu Yilan; Zheng Zhihui; Yan Liwei; Wang Xihe

    2001-01-01

    There are 264 cell for fastening fuel rods in the grid of 17 x 17 fuel assembly of PWR. The height differences of top and bottom dimples in a grid is an important quality characteristic of the grid. The report deals with measuring machine and method for dimples height differences of the grid. The device has two measuring probes. The Parallel Leaf Spring is used for transmitting the little displacement between two probes. The uncertainty of the device is σ≤4 μm. The measuring method is shown to be practicable

  14. Electron density measurement in an evolving plasma. Experimental devices

    International Nuclear Information System (INIS)

    Consoli, Terenzio; Dagai, Michel

    1960-01-01

    The experimental devices described here allow the electron density measurements in the 10 16 e/m 3 to 10 20 e/m 3 interval. Reprint of a paper published in Comptes rendus des seances de l'Academie des Sciences, t. 250, p. 1223-1225, sitting of 15 February 1960 [fr

  15. Simple measurement of 14C in the environment using gel suspension method

    International Nuclear Information System (INIS)

    Wakabayashi, Genichiro; Oura, Hirotaka; Nagao, Kenjiro; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa

    1999-01-01

    A gel suspension method using N-lauroyl-L-glutamic-α, γ-dibutylamide as gelling agent and calcium carbonate as sample was studied and it was proved a more simple measurement method of 14 C in environment than the ordinary method. 100, 20 and 7 ml of sample could introduce 3.6, 0.72 and 0.252 g of carbon, respectively. When 100 ml and 20 ml of vial introduced the maximum carbon, the lower limit of detection was about 0.3 dpm/g-C and 0.5 dpm/g-C, respectively. These values showed that this method was able to determine 14 C in the environment. The value of sample has been constant for two years or more. This fact indicated the sample prepared by this method was good for repeat measurement and long-term storage. Many samples prepared by the same calcium carbonate showed almost same values. The concentrations of 14 C in the growth rings of a tree and in rice in the environment were determined and the results agreed with the values in the references. From these above results, this method is more simple measurement method of 14 C in the environment than the ordinary method and can apply to determine 14 C in and around the nuclear installation. (S.Y.)

  16. Using Quantum Confinement to Uniquely Identify Devices

    Science.gov (United States)

    Roberts, J.; Bagci, I. E.; Zawawi, M. A. M.; Sexton, J.; Hulbert, N.; Noori, Y. J.; Young, M. P.; Woodhead, C. S.; Missous, M.; Migliorato, M. A.; Roedig, U.; Young, R. J.

    2015-11-01

    Modern technology unintentionally provides resources that enable the trust of everyday interactions to be undermined. Some authentication schemes address this issue using devices that give a unique output in response to a challenge. These signatures are generated by hard-to-predict physical responses derived from structural characteristics, which lend themselves to two different architectures, known as unique objects (UNOs) and physically unclonable functions (PUFs). The classical design of UNOs and PUFs limits their size and, in some cases, their security. Here we show that quantum confinement lends itself to the provision of unique identities at the nanoscale, by using fluctuations in tunnelling measurements through quantum wells in resonant tunnelling diodes (RTDs). This provides an uncomplicated measurement of identity without conventional resource limitations whilst providing robust security. The confined energy levels are highly sensitive to the specific nanostructure within each RTD, resulting in a distinct tunnelling spectrum for every device, as they contain a unique and unpredictable structure that is presently impossible to clone. This new class of authentication device operates with minimal resources in simple electronic structures above room temperature.

  17. A new UV-curing elastomeric substrate for rapid prototyping of microfluidic devices

    Science.gov (United States)

    Alvankarian, Jafar; Yeop Majlis, Burhanuddin

    2012-03-01

    Rapid prototyping in the design cycle of new microfluidic devices is very important for shortening time-to-market. Researchers are facing the challenge to explore new and suitable substrates with simple and efficient microfabrication techniques. In this paper, we introduce and characterize a UV-curing elastomeric polyurethane methacrylate (PUMA) for rapid prototyping of microfluidic devices. The swelling and solubility of PUMA in different chemicals is determined. Time-dependent measurements of water contact angle show that the native PUMA is hydrophilic without surface treatment. The current monitoring method is used for measurement of the electroosmotic flow mobility in the microchannels made from PUMA. The optical, physical, thermal and mechanical properties of PUMA are evaluated. The UV-lithography and molding process is used for making micropillars and deep channel microfluidic structures integrated to the supporting base layer. Spin coating is characterized for producing different layer thicknesses of PUMA resin. A device is fabricated and tested for examining the strength of different bonding techniques such as conformal, corona treating and semi-curing of two PUMA layers in microfluidic application and the results show that the bonding strengths are comparable to that of PDMS. We also report fabrication and testing of a three-layer multi inlet/outlet microfluidic device including a very effective fluidic interconnect for application demonstration of PUMA as a promising new substrate. A simple micro-device is developed and employed for observing the pressure deflection of membrane made from PUMA as a very effective elastomeric valve in microfluidic devices.

  18. Modified sine bar device measures small angles with high accuracy

    Science.gov (United States)

    Thekaekara, M.

    1968-01-01

    Modified sine bar device measures small angles with enough accuracy to calibrate precision optical autocollimators. The sine bar is a massive bar of steel supported by two cylindrical rods at one end and one at the other.

  19. Measurement device-independent quantum dialogue

    Science.gov (United States)

    Maitra, Arpita

    2017-12-01

    Very recently, the experimental demonstration of quantum secure direct communication (QSDC) with state-of-the-art atomic quantum memory has been reported (Zhang et al. in Phys Rev Lett 118:220501, 2017). Quantum dialogue (QD) falls under QSDC where the secrete messages are communicated simultaneously between two legitimate parties. The successful experimental demonstration of QSDC opens up the possibilities for practical implementation of QD protocols. Thus, it is necessary to analyze the practical security issues of QD protocols for future implementation. Since the very first proposal for QD by Nguyen (Phys Lett A 328:6-10, 2004), a large number of variants and extensions have been presented till date. However, all of those leak half of the secret bits to the adversary through classical communications of the measurement results. In this direction, motivated by the idea of Lo et al. (Phys Rev Lett 108:130503, 2012), we propose a measurement device-independent quantum dialogue scheme which is resistant to such information leakage as well as side-channel attacks. In the proposed protocol, Alice and Bob, two legitimate parties, are allowed to prepare the states only. The states are measured by an untrusted third party who may himself behave as an adversary. We show that our protocol is secure under this adversarial model. The current protocol does not require any quantum memory, and thus, it is inherently robust against memory attacks. Such robustness might not be guaranteed in the QSDC protocol with quantum memory (Zhang et al. 2017).

  20. Integrated neuron circuit for implementing neuromorphic system with synaptic device

    Science.gov (United States)

    Lee, Jeong-Jun; Park, Jungjin; Kwon, Min-Woo; Hwang, Sungmin; Kim, Hyungjin; Park, Byung-Gook

    2018-02-01

    In this paper, we propose and fabricate Integrate & Fire neuron circuit for implementing neuromorphic system. Overall operation of the circuit is verified by measuring discrete devices and the output characteristics of the circuit. Since the neuron circuit shows asymmetric output characteristic that can drive synaptic device with Spike-Timing-Dependent-Plasticity (STDP) characteristic, the autonomous weight update process is also verified by connecting the synaptic device and the neuron circuit. The timing difference of the pre-neuron and the post-neuron induce autonomous weight change of the synaptic device. Unlike 2-terminal devices, which is frequently used to implement neuromorphic system, proposed scheme of the system enables autonomous weight update and simple configuration by using 4-terminal synapse device and appropriate neuron circuit. Weight update process in the multi-layer neuron-synapse connection ensures implementation of the hardware-based artificial intelligence, based on Spiking-Neural- Network (SNN).

  1. The glucose enzyme electrode: is simple peroxide detection at a needle sensor acceptable?

    Science.gov (United States)

    Vadgama, P; Mullen, W; Churchouse, S; Battersby, C

    1988-01-01

    Needle type devices have been fabricated based on Pt anodes (to detect H2O2) mounted with stainless steel needles to act as the reference. Coating of these devices with glucose oxidase allowed glucose measurement, but with high dependence on stirring and background pO2 levels as well as a restricted glucose assay range. By wet dipcoating of microporous polyurethane or the application of preformed porous membranes, the linear range has been extended up to 70 mM glucose, to give minimal pO2 dependence and insensitivity to stirring. With incorporation of polyethersulphone membranes, blood measurement was possible with high selectivity (y = 0.954x + 0.202, r = 0.991, n = 48). This establishes that simple peroxide detection at a needle sensor is acceptable, and can now be focussed on increasing biocompatibility.

  2. Simple graphene chemiresistors as pH sensors: fabrication and characterization

    Science.gov (United States)

    Lei, Nan; Li, Pengfei; Xue, Wei; Xu, Jie

    2011-10-01

    We report the fabrication and characterization of a simple gate-free graphene device as a pH sensor. The graphene sheets are made by mechanical exfoliation. Platinum contact electrodes are fabricated with a mask-free process using a focused ion beam and then expanded by silver paint. Annealing is used to improve the electrical contact. The experiment on the fabricated graphene device shows that the resistance of the device decreases linearly with increasing pH values (in the range of 4-10) in the surrounding liquid environment. The resolution achieved in our experiments is approximately 0.3 pH in alkali environment. The sensitivity of the device is calculated as approximately 2 kΩ pH-1. The simple configuration, miniaturized size and integration ability make graphene-based sensors promising candidates for future micro/nano applications.

  3. Simple graphene chemiresistors as pH sensors: fabrication and characterization

    International Nuclear Information System (INIS)

    Lei, Nan; Li, Pengfei; Xue, Wei; Xu, Jie

    2011-01-01

    We report the fabrication and characterization of a simple gate-free graphene device as a pH sensor. The graphene sheets are made by mechanical exfoliation. Platinum contact electrodes are fabricated with a mask-free process using a focused ion beam and then expanded by silver paint. Annealing is used to improve the electrical contact. The experiment on the fabricated graphene device shows that the resistance of the device decreases linearly with increasing pH values (in the range of 4–10) in the surrounding liquid environment. The resolution achieved in our experiments is approximately 0.3 pH in alkali environment. The sensitivity of the device is calculated as approximately 2 kΩ pH −1 . The simple configuration, miniaturized size and integration ability make graphene-based sensors promising candidates for future micro/nano applications. (technical design note)

  4. A reference device for evaluating the thermal behavior of installed multilayered wall containing a phase change material

    International Nuclear Information System (INIS)

    Pagliolico, S.L.; Sassi, G.; Cascone, Y.; Bongiovanni, R.M.

    2015-01-01

    Highlights: • Thermal analysis of installed wallboards embedding phase change material layer. • Simple devices and real conditions for thermal analysis toward a standardization. • Scanning calorimetric measurements as initial condition for data regression. • Bias correction of calorimetric measurements data by installation factors. • Practical approach to identify a reliable thermal curve for capacitive wallboards. - Abstract: Thermal inertia of lightweight building envelopes can be improved including phase change materials in multilayered wallboards. The thermal modeling of buildings for design purposes needs a robust description of the thermal properties of installed phase change materials. A standard method would improve the thermal characterization of commercial products. The aim of the study is to develop a simple methodology to obtain reliable thermal data for phase change materials integrated in multilayered wallboards. The methodology modifies differential scanning calorimetry measurements on phase change material by installation factors to obtain the apparent specific heat vs. temperature for the wallboard layer embedding phase change material. Simple cubic cells were realized as reference devices to simulate a confined environment. A dynamic model of heat transfer was developed to simulate the thermal behavior of devices. Installation factors were calculated by regression of the monitored temperatures inside and outside the devices operating under real environmental conditions. The apparent specific heat of phase change material, measured by differential scanning calorimetry at different rates, resulted in a spread of curves vs. temperature. Mean curves were used as initial condition for regression. The mean calculation method did not significantly affect the installed resulted curve. A unique curve of apparent specific heat vs. temperature best fit data measured over a wide range of experimental devices and conditions. Good regression

  5. Low-Cost Interrogation Technique for Dynamic Measurements with FBG-Based Devices.

    Science.gov (United States)

    Díaz, Camilo A R; Leitão, Cátia; Marques, Carlos A; Domingues, M Fátima; Alberto, Nélia; Pontes, Maria José; Frizera, Anselmo; Ribeiro, Moisés R N; André, Paulo S B; Antunes, Paulo F C

    2017-10-23

    Fiber Bragg gratings are widely used optical fiber sensors for measuring temperature and/or mechanical strain. Nevertheless, the high cost of the interrogation systems is the most important drawback for their large commercial application. In this work, an in-line Fabry-Perot interferometer based edge filter is explored in the interrogation of fiber Bragg grating dynamic measurements up to 5 kHz. Two devices an accelerometer and an arterial pulse wave probe were interrogated with the developed approach and the results were compared with a commercial interrogation monitor. The data obtained with the edge filter are in agreement with the commercial device, with a maximum RMSE of 0.05 being able to meet the requirements of the measurements. Resolutions of 3.6 pm and 2.4 pm were obtained, using the optical accelerometer and the arterial pulse wave probe, respectively.

  6. A DEVICE AND METHOD FOR MEASURING TAR IN A TAR-ENVIRONMENT

    DEFF Research Database (Denmark)

    2017-01-01

    The present disclosure describes a device and corresponding method for measuring tar in a tar environment, e.g., a tar producing environment such as a stove or a combustion engine, based on UV absorption spectroscopy. A first measurement along an optical path in the tar environment is performed...

  7. Simple measurement-based admission control for DiffServ access networks

    Science.gov (United States)

    Lakkakorpi, Jani

    2002-07-01

    In order to provide good Quality of Service (QoS) in a Differentiated Services (DiffServ) network, a dynamic admission control scheme is definitely needed as an alternative to overprovisioning. In this paper, we present a simple measurement-based admission control (MBAC) mechanism for DiffServ-based access networks. Instead of using active measurements only or doing purely static bookkeeping with parameter-based admission control (PBAC), the admission control decisions are based on bandwidth reservations and periodically measured & exponentially averaged link loads. If any link load on the path between two endpoints is over the applicable threshold, access is denied. Link loads are periodically sent to Bandwidth Broker (BB) of the routing domain, which makes the admission control decisions. The information needed in calculating the link loads is retrieved from the router statistics. The proposed admission control mechanism is verified through simulations. Our results prove that it is possible to achieve very high bottleneck link utilization levels and still maintain good QoS.

  8. Development of the simple evaluation method of the soil biomass by the ATP measurement

    Czech Academy of Sciences Publication Activity Database

    Urashima, Y.; Nakajima, M.; Kaneda, Satoshi; Murakami, T.

    2007-01-01

    Roč. 78, č. 2 (2007), s. 187-190 ISSN 0029-0610 Institutional research plan: CEZ:AV0Z60660521 Keywords : simple evaluation method * soil biomass * ATP measurement Subject RIV: EH - Ecology, Behaviour

  9. Stability of the superconductive operating mode in high current-density devices

    International Nuclear Information System (INIS)

    Wipf, S.L.

    1979-01-01

    The superconductive operating mode represents a thermal equilibrium that can tolerate a certain amount of disturbance before it is lost. The basin of attraction (BOA), in many ways equivalent to a potential well, is a measure of the size of disturbance needed to lift the device from the superconductive into a resistive operating mode. The BOA for a simple geometry is calculated and discussed. Experimental results are reported, showing how the concept is used to gain information on the disturbances occurring in a superconducting device

  10. Optoelectronic device for the measurement of the absolute linear position in the micrometric displacement range

    Science.gov (United States)

    Morlanes, Tomas; de la Pena, Jose L.; Sanchez-Brea, Luis M.; Alonso, Jose; Crespo, Daniel; Saez-Landete, Jose B.; Bernabeu, Eusebio

    2005-07-01

    In this work, an optoelectronic device that provides the absolute position of a measurement element with respect to a pattern scale upon switch-on is presented. That means that there is not a need to perform any kind of transversal displacement after the startup of the system. The optoelectronic device is based on the process of light propagation passing through a slit. A light source with a definite size guarantees the relation of distances between the different elements that constitute our system and allows getting a particular optical intensity profile that can be measured by an electronic post-processing device providing the absolute location of the system with a resolution of 1 micron. The accuracy of this measuring device is restricted to the same limitations of any incremental position optical encoder.

  11. Mechanical Design of the Intensity Measurement Devices for the LHC

    CERN Document Server

    Belorhad, D; Odier, P; Thoulet, S

    2008-01-01

    The intensity measurement for the LHC ring is provided by eight current transformers (2×DCCT, 2×FBCT per beam). The measurement resolution of 1?Arms at 1s average for the DCCTs and ±10^9p in 25ns for the FBCTs is required. Such constraints call for low noise electronics and a compact magnetically shielded mechanical design. Correct integration of these devices into the vacuum system also requires the vacuum chambers equipped with the non-evaporable getter (NEG) film. The NEG is activated by heating the vacuum chamber to 200?C and more. Such temperatures affect the structure of the magnetic materials, which form the base part of the intensity measurement devices, and degrade their performace. A cooling circuit is needed. Due to the mechanical constraints, the cooling circuit, as well as heating element must form an integral part of the design. The aim of this paper is to present the solutions to these problems and discuss the mechanical construction of the DCCTs and FBCTs currently being installed in the LH...

  12. A New Cuffless Device for Measuring Blood Pressure: A Real-Life Validation Study

    NARCIS (Netherlands)

    Schoot, T.S.; Weenk, M.; Belt, T.H. van de; Engelen, L.J.L.P.G.; Goor, H. van; Bredie, S.J.H.

    2016-01-01

    BACKGROUND: Cuffless blood pressure (BP) monitoring devices, based on pulse transit time, are being developed as an easy-to-use, more convenient, fast, and relatively cheap alternative to conventional BP measuring devices based on cuff occlusion. Thereby they may provide a great alternative to BP

  13. Radioactivity concentration measuring device for radiation waste containing vessel

    International Nuclear Information System (INIS)

    Goto, Tetsuo.

    1994-01-01

    The device of the present invention can precisely and accurately measure a radioactive concentration of radioactive wastes irrespective of the radioactivity concentration distribution. Namely, a Ge detector having a collimator and a plurality of radiation detectors are placed at the outside of the radioactive waste containing vessel in such a way that it can rotate and move vertically relative to the vessel. The plurality of radiation detectors detect radiation coefficient signals at an assumed segment unit of a predetermined length in vertical direction and for every predetermined angle unit in the rotational direction. A weight measuring device determines the weight of the vessel. A computer calculates an average density of radioactivity for the region filled with radioactivity based on the determined net weight and radiation coefficient signals assuming that the volume of the radioactivity is constant. In addition, the computer calculates the amount of radioactivity in the assumed segment by conducting γ -ray absorption compensation calculation for the material in the vessel. Each of the amount of radioactivity is integrated to determine the amount of radioactivity in the vessel. (I.S.)

  14. Dynamic pipe control with a multiple digit automatic measuring device

    International Nuclear Information System (INIS)

    Jenzer, P.

    1984-01-01

    With the flow rotating method, thin-walled pipes can be produced with very tight tolerances and high mechanical sturdiness. The measuring device permits a dynamic control of these pipes, the outer diameter of which can lie between 70 and 300 mm, the length between 500 and 2000 mm and the wall thickness between 0,5 and 10 mm. Depending on the pipe type, up to 27 measurements in a maximum of 5 measuring levels are to be controlled. (orig.) [de

  15. New devices for radon measurements

    International Nuclear Information System (INIS)

    Sevostyanov, V.N.

    2004-01-01

    This work includes the description of two new devices for radon surveys developed by the authors and produced in Kazakhstan. The first appliance is 'Ramon-Radon-01' used to measure 222 Rn radon in various mediums such as air, water, soil, and radon exhalation. The major advantage of the appliance lies in the absence of radioactive pollution in it after measurements. The appliances widely used in the CIS such as 'RAA-01', 'Alpharad' (produced by 'MTM Zaschita', Russia) and 'Alphaguard' (Germany) take samples directly to the measuring camera. For instance, the activity concentration of samples after they are taken by 'RAA-01' and 'Alpharad' is measured by means of electrostatic precipitation of RaA ( 218 Po) atoms to the square of semiconductor detector with subsequent registration of RaA alpha decay. The obvious disadvantage is that the subsequent measurement of relatively small 222 Rn activity concentration values after great values of 222 Rn activity concentration have been obtained requires a considerable exposure of the appliance sometimes exceeding 10 hours. Therefore, appliances register a relatively low value of the top measurement range of 20 KBq/m 3 . 'Alphaguard' has similar limitation resulting from precipitation of radon daughter decay products on the walls of ionizing chamber where radon activity concentration is measured. The radioactive lag of 'RAA-01', 'Alpharad' and 'Alphaguard' makes them of little use as well for automatic monitoring in the conditions of abruptly time negative derivatives on change of radon activity concentration. The second advantage is that 'Ramon-Radon-01', as opposed to above described appliances, registers almost zero radioactive lag, thanks to its constructive peculiarities which enable an abrupt increase of top range of measured value up to 5x10 5 Bq/m 3 , only limited by velocity of electron units of the appliance. The third advantage is that measurement discontinuity is determined only by time of full measurement cycle

  16. Establishment and application of standard devices for radioactivity measurement

    International Nuclear Information System (INIS)

    Zhou Changgui; Li Xingyuan; Chen Zigen

    1991-03-01

    In order to establish the radioactivity measurement standards a 4πβ-γ coincidence apparatus and a 4πγ ionization chamber have been installed in the laboratory. The 4πβ-γ coincidence apparatus is for absolute measurement, and its uncertainty is ±(0.3∼5)%. The 4πγ ionization chamber is for working standard, and its uncertainty is ±(1∼5)%. The combination of these devices can meet the quality requirements controlled by National Verification System in the transfer of radioactivity values

  17. A simple predistortion technique for suppression of nonlinear effects in periodic signals generated by nonlinear transducers

    Science.gov (United States)

    Novak, A.; Simon, L.; Lotton, P.

    2018-04-01

    Mechanical transducers, such as shakers, loudspeakers and compression drivers that are used as excitation devices to excite acoustical or mechanical nonlinear systems under test are imperfect. Due to their nonlinear behaviour, unwanted contributions appear at their output besides the wanted part of the signal. Since these devices are used to study nonlinear systems, it should be required to measure properly the systems under test by overcoming the influence of the nonlinear excitation device. In this paper, a simple method that corrects distorted output signal of the excitation device by means of predistortion of its input signal is presented. A periodic signal is applied to the input of the excitation device and, from analysing the output signal of the device, the input signal is modified in such a way that the undesirable spectral components in the output of the excitation device are cancelled out after few iterations of real-time processing. The experimental results provided on an electrodynamic shaker show that the spectral purity of the generated acceleration output approaches 100 dB after few iterations (1 s). This output signal, applied to the system under test, is thus cleaned from the undesirable components produced by the excitation device; this is an important condition to ensure a correct measurement of the nonlinear system under test.

  18. COMPARISON OF A HEAD MOUNTED IMPACT MEASUREMENT DEVICE TO THE HYBRID III ANTHROPOMORPHIC TESTING DEVICE IN A CONTROLLED LABORATORY SETTING.

    Science.gov (United States)

    Schussler, Eric; Stark, David; Bolte, John H; Kang, Yun Seok; Onate, James A

    2017-08-01

    Reports estimate that 1.6 to 3.8 million cases of concussion occur in sports and recreation each year in the United States. Despite continued efforts to reduce the occurrence of concussion, the rate of diagnosis continues to increase. The mechanisms of concussion are thought to involve linear and rotational head accelerations and velocities. One method of quantifying the kinematics experienced during sport participation is to place measurement devices into the athlete's helmet or directly on the athlete's head. The purpose of this research to determine the accuracy of a head mounted device for measuring the head accelerations experienced by the wearer. This will be accomplished by identifying the error in Peak Linear Acceleration (PLA), Peak Rotational Acceleration (PRA) and Peak Rotational Velocity (PRV) of the device. Laboratory study. A helmeted Hybrid III 50th percentile male headform was impacted via a pneumatic ram from the front, side, rear, front oblique and rear oblique at speeds from 1.5 to 5 m/s. The X2 Biosystems xPatch® (Seattle, WA) sensor was placed on the headform's right side at the approximate location of the mastoid process. Measures of PLA, PRA, PRV from the xPatch ® and Hybrid III were analyzed for Root Mean Square Error (RMSE), and Absolute and Relative Error (AE, RE). Seventy-six impacts were analyzed. All measures of correlation, fixed through the origin, were found to be strong: PLA R 2 =0.967 pstandard yet above the average error of testing devices in both PLA and PRA, but a low error in PRV. PLA measures from the xPatch® system demonstrated a high level of correlation with the PLA data from the Hybrid III mounted data collection system. 3.

  19. Design of Gear Churning Power Loss Measurement Device

    OpenAIRE

    Wang Bin; Zhou Ya Jie; Wang Ping

    2017-01-01

    To explore the impacts of gear churning power losses, a research was conducted to achieve the internal causes of power losses of churning gear by designing a gear churning power losses measurement device. The gear churning power losses could be influenced by different gear modules, the number of teeth and the axial position of gear. Finally, the impacts of gear churning power losses were discussed by comparing experimental data and theoretical data.

  20. Device for measuring active, reactive and apparent power

    Energy Technology Data Exchange (ETDEWEB)

    Bartosinski, E.; Wieland, J.

    1982-09-30

    The plan consists of a traditional electrodynamic mechanism for measuring power (IM) supplemented by three switches, two rectifiers, resistor, included in parallel, and phaseshifting throttle included in series with the voltage coil of the IM. This makes it possible by selection to perform three types of measurements: active power of alternating current or power of direct current, only the voltage coils and the IM current are engaged; reactive power, the resistor and the throttle are additionally engaged by the aforementioned method; complete (apparent) power--the current and the voltage are supplied directly to the IM coils, but in contrast to the first case, through rectifiers. The influence of the highest harmonic components of voltage and current which are not significant for industrial measurements can be eliminated in necessary cases using filtering devices.

  1. Experimental study on a simple Ranque-Hilsch vortex tube

    NARCIS (Netherlands)

    Gao, C.; Bosschaart, K.J.; Zeegers, J.C.H.; Waele, de A.T.A.M.

    2005-01-01

    The Ranque-Hilsch vortex tube is a device by which cold gas can be generated using compressed gas. To understand the cooling mechanism of this device, it is necessary to know the pressure, temperature, and velocity distributions inside the tube. In order to investigate this, a simple vortex tube is

  2. A Novel Method for Short Distance Measurements

    International Nuclear Information System (INIS)

    Fernandez, M.G.; Ferrando, A.; Josa, M.I.; Molinero, A.; Oller, J.C.; Arce, P.; Calvo, E.; Figueroa, C.F.; Garcia, C.F.; Rodigrido, T.; Vila, I.; Virto, A.L.

    1998-01-01

    A new, accurate and un expensive device for measuring short distances, intended for monitoring in LHC experiments is presented. Data taken with a very simple prototype are shown and performance is extracted. (Author) 4 refs

  3. A PDMS Device Coupled with Culture Dish for In Vitro Cell Migration Assay.

    Science.gov (United States)

    Lv, Xiaoqing; Geng, Zhaoxin; Fan, Zhiyuan; Wang, Shicai; Pei, WeiHua; Chen, Hongda

    2018-04-30

    Cell migration and invasion are important factors during tumor progression and metastasis. Wound-healing assay and the Boyden chamber assay are efficient tools to investigate tumor development because both of them could be applied to measure cell migration rate. Therefore, a simple and integrated polydimethylsiloxane (PDMS) device was developed for cell migration assay, which could perform quantitative evaluation of cell migration behaviors, especially for the wound-healing assay. The integrated device was composed of three units, which included cell culture dish, PDMS chamber, and wound generation mold. The PDMS chamber was integrated with cell culture chamber and could perform six experiments under different conditions of stimuli simultaneously. To verify the function of this device, it was utilized to explore the tumor cell migration behaviors under different concentrations of fetal bovine serum (FBS) and transforming growth factor (TGF-β) at different time points. This device has the unique capability to create the "wound" area in parallel during cell migration assay and provides a simple and efficient platform for investigating cell migration assay in biomedical application.

  4. Near-surface viscosity measurements with a love acoustic wave device

    International Nuclear Information System (INIS)

    Collings, A.F.; Cooper, B.J.; Lappas, S.; Sor, J.A.

    1999-01-01

    Full text: In the last decade, considerable research effort has been directed towards interfacing piezoelectric transducers with biological detection systems to produce efficient and highly selective biosensors. Several types of piezoelectric or, more specifically, acoustic wave transducers have been investigated. Our group has developed Love wave (guided surface skimming wave) devices which are made by attaching a thin overlayer with the appropriate acoustic properties to the surface of a conventional surface horizontal mode device. An optimised layer concentrates most of the propagating wave energy in the guiding layer and can improve the device sensitivity in detecting gas-phase mass loading on the surface some 20- to 40-fold. Love wave devices used in liquid phase sensing will also respond to viscous, as well as mass, loading on the device surface. We have studied the propagation of viscous waves into liquid sitting on a Love wave device both theoretically and experimentally. Modelling of the effect of a viscous liquid layer on a Love wave propagating in a layered medium predicts the velocity profile in the solid substrate and in the adjoining liquid. This is a function of the thickness of the guiding layer, the elastic properties of the guiding layer and the piezoelectric substrate, and of the viscosity and density of the liquid layer. We report here on measurements of the viscosity of aqueous glycerine solutions made with a quartz Love wave device with a 5.5 μm SiO 2 guiding layer. The linear relationship between the decrease in the device frequency and the square root of the viscosity density product is accurately observed at Newtonian viscosities. At higher viscosities, there is an increase in damping, the insertion loss of the device saturates, Δf is no longer proportional to (ηp) l/2 and reaches a maximum. We also show results for the determination of the gelation time in protein and inorganic aqueous gels and for the rate of change of viscosity with

  5. Laser-based irradiation apparatus and method to measure the functional dose-rate response of semiconductor devices

    Science.gov (United States)

    Horn, Kevin M [Albuquerque, NM

    2008-05-20

    A broad-beam laser irradiation apparatus can measure the parametric or functional response of a semiconductor device to exposure to dose-rate equivalent infrared laser light. Comparisons of dose-rate response from before, during, and after accelerated aging of a device, or from periodic sampling of devices from fielded operational systems can determine if aging has affected the device's overall functionality. The dependence of these changes on equivalent dose-rate pulse intensity and/or duration can be measured with the apparatus. The synchronized introduction of external electrical transients into the device under test can be used to simulate the electrical effects of the surrounding circuitry's response to a radiation exposure while exposing the device to dose-rate equivalent infrared laser light.

  6. Radiation dose rate measuring device

    International Nuclear Information System (INIS)

    Sorber, R.

    1987-01-01

    A portable device is described for in-field usage for measuring the dose rate of an ambient beta radiation field, comprising: a housing, substantially impervious to beta radiation, defining an ionization chamber and having an opening into the ionization chamber; beta radiation pervious electrically-conductive window means covering the opening and entrapping, within the ionization chamber, a quantity of gaseous molecules adapted to ionize upon impact with beta radiation particles; electrode means disposed within the ionization chamber and having a generally shallow concave surface terminating in a generally annular rim disposed at a substantially close spacing to the window means. It is configured to substantially conform to the window means to define a known beta radiation sensitive volume generally between the window means and the concave surface of the electrode means. The concave surface is effective to substantially fully expose the beta radiation sensitive volume to the radiation field over substantially the full ambient area faced by the window means

  7. Printing method for organic light emitting device lighting

    Science.gov (United States)

    Ki, Hyun Chul; Kim, Seon Hoon; Kim, Doo-Gun; Kim, Tae-Un; Kim, Snag-Gi; Hong, Kyung-Jin; So, Soon-Yeol

    2013-03-01

    Organic Light Emitting Device (OLED) has a characteristic to change the electric energy into the light when the electric field is applied to the organic material. OLED is currently employed as a light source for the lighting tools because research has extensively progressed in the improvement of luminance, efficiency, and life time. OLED is widely used in the plate display device because of a simple manufacture process and high emitting efficiency. But most of OLED lighting projects were used the vacuum evaporator (thermal evaporator) with low molecular. Although printing method has lower efficiency and life time of OLED than vacuum evaporator method, projects of printing OLED actively are progressed because was possible to combine with flexible substrate and printing technology. Printing technology is ink-jet, screen printing and slot coating. This printing method allows for low cost and mass production techniques and large substrates. In this research, we have proposed inkjet printing for organic light-emitting devices has the dominant method of thick film deposition because of its low cost and simple processing. In this research, the fabrication of the passive matrix OLED is achieved by inkjet printing, using a polymer phosphorescent ink. We are measured optical and electrical characteristics of OLED.

  8. Indoor measurement of photovoltaic device characteristics at varying irradiance, temperature and spectrum for energy rating

    International Nuclear Information System (INIS)

    Bliss, M; Betts, T R; Gottschalg, R

    2010-01-01

    The first three-dimensional performance matrix for use in photovoltaic (PV) energy rating is reported utilizing a novel energy rating solar simulator based on LEDs. Device characteristics are measured indoors at varying irradiance (G), temperature (T) and spectrum (E). This opens the possibility for a more accurate measurement system for energy yield prediction of PV devices, especially for devices with high spectral dependence such as wide bandgap solar cells as they take into account spectral changes in the light. The main aspects of the LED-based solar simulator used are briefly described. A measurement method is developed and detailed in the paper, which takes into account the current imperfections in the achievable spectrum. Measurement results for a crystalline silicon solar cell are used to demonstrate the measurement approach. An uncertainty analysis of the measurement system is given, resulting in an overall absolute uncertainty of 4.3% (coverage factor k = 2) in maximum power measurements at 765 W m −2 irradiance with scope for further improvements

  9. Measuring device for weight of glass of glass solidification product to be charged

    International Nuclear Information System (INIS)

    Yasutake, Nobuhiro; Arai, Masaki; Akashi, Ken-ichi

    1998-01-01

    The present invention provides a device for accurately calculating the weight of molten glass to be charged during manufacturing glass solidification products of radioactive liquid wastes. Namely, a discharge nozzle at the lower end of a glass melting furnace and an upper end of a vessel for glass solidification materials are connected by a connecting device extensible vertically in a cylindrical shape. Molten glasses are flown down by way of the connecting device and filled into the vessel for solidification products. A first scale is constituted so as to measure the weight of load, and the vessel for solidification products are loaded. A second scale is constituted so as to measure the own weight and a weight of load, and is interposed between a flange at the circumference of a charging port and the lower end of the connecting device, and has an opening for flowing down the molten glass at the central portion. With such a constitution, the first scale can weigh the total of the weight of molten glass charged to the vessel for solidification products, the weight of the vessel for solidification products, the counterforce from the connecting device and the weight of the second scale. If the measured value of the secondary scale and the weight of the vessel for solidification products are subtracted from the former value, the weight of the charged molten glass can be determined. (I.S.)

  10. Simple Numerical Simulation of Strain Measurement

    Science.gov (United States)

    Tai, H.

    2002-01-01

    By adopting the basic principle of the reflection (and transmission) of a plane polarized electromagnetic wave incident normal to a stack of films of alternating refractive index, a simple numerical code was written to simulate the maximum reflectivity (transmittivity) of a fiber optic Bragg grating corresponding to various non-uniform strain conditions including photo-elastic effect in certain cases.

  11. Device for accurately measuring mass flow of gases

    Science.gov (United States)

    Hylton, James O.; Remenyik, Carl J.

    1994-01-01

    A device for measuring mass flow of gases which utilizes a substantially buoyant pressure vessel suspended within a fluid/liquid in an enclosure. The pressure vessel is connected to a weighing device for continuously determining weight change of the vessel as a function of the amount of gas within the pressure vessel. In the preferred embodiment, this pressure vessel is formed from inner and outer right circular cylindrical hulls, with a volume between the hulls being vented to the atmosphere external the enclosure. The fluid/liquid, normally in the form of water typically with an added detergent, is contained within an enclosure with the fluid/liquid being at a level such that the pressure vessel is suspended beneath this level but above a bottom of the enclosure. The buoyant pressure vessel can be interconnected with selected valves to an auxiliary pressure vessel so that initial flow can be established to or from the auxiliary pressure vessel prior to flow to or from the buoyant pressure vessel.

  12. Simulations and measurements of coupling impedance for modern particle accelerator devices

    CERN Document Server

    AUTHOR|(CDS)2158523; Biancacci, Nicolò; Mostacci, Andrea

    In this document it has been treated the study of the coupling impedance in modern devices, already installed or not, in different particle accelerators. In the specific case: • For a device in-phase of project, several simulations for impedance calculation have been done. • For a component already realized and used, measurements of coupling impedance value have been done. Simulations are used to determine the impact of the interconnect between to magnets, designed for the future particle accelerator FCC, on the overall impedance of the machine which is about 100 km long. In particular has been done a check between theory, simulations and measurements of components already built, allowing a better and deeper study of the component we have analysed. Controls that probably will be helpful to have a clear guideline in future works. The measurements instead concern in an existing component that was already used in LHC, the longest particle accelerator ever realised on the planet, 27 km long. The coupling impe...

  13. Analysis of liquid medication dose errors made by patients and caregivers using alternative measuring devices.

    Science.gov (United States)

    Ryu, Gyeong Suk; Lee, Yu Jeung

    2012-01-01

    Patients use several types of devices to measure liquid medication. Using a criterion ranging from a 10% to 40% variation from a target 5 mL for a teaspoon dose, previous studies have found that a considerable proportion of patients or caregivers make errors when dosing liquid medication with measuring devices. To determine the rate and magnitude of liquid medication dose errors that occur with patient/caregiver use of various measuring devices in a community pharmacy. Liquid medication measurements by patients or caregivers were observed in a convenience sample of community pharmacy patrons in Korea during a 2-week period in March 2011. Participants included all patients or caregivers (N = 300) who came to the pharmacy to buy over-the-counter liquid medication or to have a liquid medication prescription filled during the study period. The participants were instructed by an investigator who was also a pharmacist to select their preferred measuring devices from 6 alternatives (etched-calibration dosing cup, printed-calibration dosing cup, dosing spoon, syringe, dispensing bottle, or spoon with a bottle adapter) and measure a 5 mL dose of Coben (chlorpheniramine maleate/phenylephrine HCl, Daewoo Pharm. Co., Ltd) syrup using the device of their choice. The investigator used an ISOLAB graduated cylinder (Germany, blue grad, 10 mL) to measure the amount of syrup dispensed by the study participants. Participant characteristics were recorded including gender, age, education level, and relationship to the person for whom the medication was intended. Of the 300 participants, 257 (85.7%) were female; 286 (95.3%) had at least a high school education; and 282 (94.0%) were caregivers (parent or grandparent) for the patient. The mean (SD) measured dose was 4.949 (0.378) mL for the 300 participants. In analysis of variance of the 6 measuring devices, the greatest difference from the 5 mL target was a mean 5.552 mL for 17 subjects who used the regular (etched) dosing cup and 4

  14. A measurement device for electromagnetic flow tomography

    Science.gov (United States)

    Vauhkonen, M.; Hänninen, A.; Lehtikangas, O.

    2018-01-01

    Electromagnetic flow meters have succesfully been used in many industries to measure the mean flow velocity of conductive liquids. This technology works reliably in single phase flows with axisymmetric flow profiles but can be inaccurate with asymmetric flows, which are encountered, for example, in multiphase flows, pipe elbows and T-junctions. Some computational techniques and measurement devices with multiple excitation coils and measurement electrodes have recently been proposed to be used in cases of asymmetric flows. In earlier studies, we proposed a computational approach for electromagnetic flow tomography (EMFT) for estimating velocity fields utilizing several excitation coils and a set of measurement electrodes attached to the surface of the pipe. This approach has been shown to work well with simulated data but has not been tested extensively with real measurements. In this paper, an EMFT system with four excitation coils and 16 measurement electrodes is introduced. The system is capable of using both square wave and sinusoidal coil current excitations and all the coils can be excited individually, also enabling parallel excitations with multiple frequencies. The studies undertaken in the paper demonstrate that the proposed EMFT system, together with the earlier introduced velocity field reconstruction approach, is capable of producing reliable velocify field estimates in a laboratory environment with both axisymmetric and asymmetric single phase flows.

  15. High-precision methods and devices for in situ measurements of thermally induced aberrations in optical elements

    International Nuclear Information System (INIS)

    Zelenogorsky, Victor V.; Solovyov, Alexander A.; Kozhevatov, Ilya E.; Kamenetsky, Eugene E.; Rudenchik, Eugene A.; Palashov, Oleg V.; Silin, Dmitry E.; Khazanov, Efim A.

    2006-01-01

    An optical system that comprises two devices for remote measurements, a broadband optical interferometer and a scanning Hartmann sensor, is described. The results of simultaneous measurements with both devices and the results of numerical modeling of sample surface heating are presented

  16. Measuring the power consumption of social media applications on a mobile device

    Science.gov (United States)

    Dunia, A. I. M.; Suherman; Rambe, A. H.; Fauzi, R.

    2018-03-01

    As fully connected social media applications become popular and require all time connection, the power consumption on mobile device battery increases significantly. As power supplied by a battery is limited, social media application should be designed to be less power consuming. This paper reports the power consumption measurement of social media running on a mobile device. Experimental circuit was developed by using a microcontroller measuring an android smartphone on a 802.11 controlled network. The experiment results show that whatsapp consumes the power less than others in stand by and chat. While other states are dominated by line. The blackberry consumes the power the worst.

  17. Measurement of Underwater Operational Noise Emitted by Wave and Tidal Stream Energy Devices.

    Science.gov (United States)

    Lepper, Paul A; Robinson, Stephen P

    2016-01-01

    The increasing international growth in the development of marine and freshwater wave and tidal energy harvesting systems has been followed by a growing requirement to understand any associated underwater impact. Radiated noise generated during operation is dependent on the device's physical properties, the sound-propagation environment, and the device's operational state. Physical properties may include size, distribution in the water column, and mechanics/hydrodynamics. The sound-propagation environment may be influenced by water depth, bathymetry, sediment type, and water column acoustic properties, and operational state may be influenced by tidal cycle and wave height among others This paper discusses some of the challenges for measurement of noise characteristics from these devices as well as a case study of the measurement of radiated noise from a full-scale wave energy converter.

  18. Assembly for electrical conductivity measurements in the piston cylinder device

    Science.gov (United States)

    Watson, Heather Christine [Dublin, CA; Roberts, Jeffrey James [Livermore, CA

    2012-06-05

    An assembly apparatus for measurement of electrical conductivity or other properties of a sample in a piston cylinder device wherein pressure and heat are applied to the sample by the piston cylinder device. The assembly apparatus includes a body, a first electrode in the body, the first electrode operatively connected to the sample, a first electrical conductor connected to the first electrode, a washer constructed of a hard conducting material, the washer surrounding the first electrical conductor in the body, a second electrode in the body, the second electrode operatively connected to the sample, and a second electrical conductor connected to the second electrode.

  19. Molecular implementation of simple logic programs.

    Science.gov (United States)

    Ran, Tom; Kaplan, Shai; Shapiro, Ehud

    2009-10-01

    Autonomous programmable computing devices made of biomolecules could interact with a biological environment and be used in future biological and medical applications. Biomolecular implementations of finite automata and logic gates have already been developed. Here, we report an autonomous programmable molecular system based on the manipulation of DNA strands that is capable of performing simple logical deductions. Using molecular representations of facts such as Man(Socrates) and rules such as Mortal(X) logical deductions and delivers the result. This prototype is the first simple programming language with a molecular-scale implementation.

  20. Plasma electron density measurement with multichannel microwave interferometer on the HL-1 tokamak device

    International Nuclear Information System (INIS)

    Xu Deming; Zhang Hongyin; Liu Zetian; Ding Xuantong; Li Qirui; Wen Yangxi

    1989-11-01

    A multichannel microwave interferometer which is composed of different microwave interferometers (one 2 mm band, one 4 mm band and two 8 mm band) has been used to measure the plasma electron density on HL-1 tokamak device. The electron density approaching to 5 x 10 13 cm -3 is measured by a 2 mm band microwave interferometer. In the determinable range, the electron density profile in the cross-section on HL-1 device has been measured by this interferometer. A microcomputer data processing system is also developed

  1. In-chip optical CD measurements for non-volatile memory devices

    Science.gov (United States)

    Vasconi, Mauro; Kremer, Stephanie; Polli, M.; Severgnini, Ermes; Trovati, Silvia S.

    2006-03-01

    A potential limitation to a wider usage of the scatterometry technique for CD evaluation comes from its requirement of dedicated regular measurement gratings, located in wafer scribe lanes. In fact, the simplification of the original chip layout that is often requested to design these gratings may impact on their printed dimension and shape. Etched gratings might also suffer from micro-loading effects other than in the circuit. For all these reasons, measurements collected therein may not represent the real behavior of the device. On the other hand, memory devices come with large sectors that usually possess the characteristics required for a proper scatterometry evaluation. In particular, for a leading edge flash process this approach is in principle feasible for the most critical process steps. The impact of potential drawbacks, mainly lack of pattern regularity within the tool probe area, is investigated. More, a very large sampling plan on features with equal nominal CD and density spread over the same exposure shot becomes feasible, thus yielding a deeper insight of the overall lithographic process window and a quantitative method to evaluate process equipment performance along time by comparison to acceptance data and/or last preventive maintenance. All the results gathered in the device main array are compared to those collected in standard scatterometry targets, tailored to the characteristics of the considered layers in terms of designed CD, pitch, stack and orientation.

  2. Assessment of a portable device for the quantitative measurement of ankle joint stiffness in spastic individuals

    DEFF Research Database (Denmark)

    Lorentzen, Jakob; Grey, Michael J; Geertsen, Svend Sparre

    2012-01-01

    was measured with the portable device and a stationary torque motor. Inter- and intra-rater reliability was assessed with the intra-class correlation coefficient (ICC). RESULTS: Stiffness measures with the portable and stationary devices were significantly correlated for controls and MS participants (p...

  3. Testing limits to airflow perturbation device (APD measurements

    Directory of Open Access Journals (Sweden)

    Jamshidi Shaya

    2008-10-01

    Full Text Available Abstract Background The Airflow Perturbation Device (APD is a lightweight, portable device that can be used to measure total respiratory resistance as well as inhalation and exhalation resistances. There is a need to determine limits to the accuracy of APD measurements for different conditions likely to occur: leaks around the mouthpiece, use of an oronasal mask, and the addition of resistance in the respiratory system. Also, there is a need for resistance measurements in patients who are ventilated. Method Ten subjects between the ages of 18 and 35 were tested for each station in the experiment. The first station involved testing the effects of leaks of known sizes on APD measurements. The second station tested the use of an oronasal mask used in conjunction with the APD during nose and mouth breathing. The third station tested the effects of two different resistances added in series with the APD mouthpiece. The fourth station tested the usage of a flexible ventilator tube in conjunction with the APD. Results All leaks reduced APD resistance measurement values. Leaks represented by two 3.2 mm diameter tubes reduced measured resistance by about 10% (4.2 cmH2O·sec/L for control and 3.9 cm H2O·sec/L for the leak. This was not statistically significant. Larger leaks given by 4.8 and 6.4 mm tubes reduced measurements significantly (3.4 and 3.0 cm cmH2O·sec/L, respectively. Mouth resistance measured with a cardboard mouthpiece gave an APD measurement of 4.2 cm H2O·sec/L and mouth resistance measured with an oronasal mask was 4.5 cm H2O·sec/L; the two were not significantly different. Nose resistance measured with the oronasal mask was 7.6 cm H2O·sec/L. Adding airflow resistances of 1.12 and 2.10 cm H2O·sec/L to the breathing circuit between the mouth and APD yielded respiratory resistance values higher than the control by 0.7 and 2.0 cm H2O·sec/L. Although breathing through a 52 cm length of flexible ventilator tubing reduced the APD

  4. Evaluation of the performance characteristics of radon and radon-daughter concentration measurement devices under controlled environmental conditions

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1989-04-01

    The Technical Measurements Center (TMC) conducted a study to expose 10 radon and 7 radon-daughter concentration measurement devices in the DOE/GJPO Radon/Radon-Daughter Environmental Chamber for a series of 24 controlled-environment tests. The tests evaluated the devices' response to temperature, relative humidity, dew point, condensation-nuclei concentration, radon-daughter/radon equilibrium ratio, and non-uniform radon and radon-daughter concentration. Devices were evaluated for linear response as a function of concentration. In addition to response to environmental parameters, the evaluation included determining the utility of the devices in providing reasonable assurance of compliance with the radon and radon-daughter concentration standards for DOE remedial action programs. This reasonable assurance criterion is based on a coefficient of variation of 25 percent for devices deployed for year-long measurements and a coefficient of variation of 18 percent for devices deployed for intermittent sampling. 39 refs., 65 figs., 33 tabs

  5. Design of a device for sky light polarization measurements.

    Science.gov (United States)

    Wang, Yujie; Hu, Xiaoping; Lian, Junxiang; Zhang, Lilian; Xian, Zhiwen; Ma, Tao

    2014-08-14

    Sky polarization patterns can be used both as indicators of atmospheric turbidity and as a sun compass for navigation. The objective of this study is to improve the precision of sky light polarization measurements by optimal design of the device used. The central part of the system is composed of a Charge Coupled Device (CCD) camera; a fish-eye lens and a linear polarizer. Algorithms for estimating parameters of the polarized light based on three images are derived and the optimal alignments of the polarizer are analyzed. The least-squares estimation is introduced for sky light polarization pattern measurement. The polarization patterns of sky light are obtained using the designed system and they follow almost the same patterns of the single-scattering Rayleigh model. Deviations of polarization angles between observation and the theory are analyzed. The largest deviations occur near the sun and anti-sun directions. Ninety percent of the deviations are less than 5° and 40% percent of them are less than 1°. The deviations decrease evidently as the degree of polarization increases. It also shows that the polarization pattern of the cloudy sky is almost identical as in the blue sky.

  6. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    International Nuclear Information System (INIS)

    Njeh, Christopher F; Caroprese, Blas; Desai, Pushkar

    2012-01-01

    The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID) or computed radiography (CR). We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence

  7. Measuring device for bending of beryllium reflector

    International Nuclear Information System (INIS)

    Nishida, Seiri; Sakamoto, Naoki.

    1994-01-01

    The device of the present invention can measure bending of a beryllium reflector formed in a reactor core of a nuclear reactor by a relatively easy operation. Namely, a sensor portion comprises a long-support that can be inserted to a fuel element-insertion hole disposed in the reactor and a plurality of distance sensors disposed in a longitudinal direction of the support. A supersonic wave sensor which is advantageous in the heat resistance, the size and the accuracy and can conduct measurement in water relatively easily is used as the distance sensors. However, other sensors, instead of the sensor described above, may also be used. The plurality of distance sensors detect the bending amount of the beryllium reflector in the longitudinal direction by such an easy operation of inserting such a sensor portion to the fuel element-insertion hole upon exchange of fuel elements. (I.S.)

  8. Electrochemical fabrication and electronic behavior of polypyrrole nano-fiber array devices

    International Nuclear Information System (INIS)

    Liu Ling; Zhao Yaomin; Jia Nengqin; Zhou Qin; Zhao Chongjun; Yan Manming; Jiang Zhiyu

    2006-01-01

    Electrochemically active Polypyrrole (PPy) nano-fiber array device was fabricated via electrochemical deposition method using aluminum anodic oxide (AAO) membrane as template. After alkaline treatment electrochemically active PPy nano-fiber lost electrochemical activity, and became electrochemically inactive PPy. The electronic properties of PPy nano-fiber array devices were measured by means of a simple method. It was found that for an indium-tin oxide/electrochemically inactive PPy nano-fiber device, the conductivity of nano-fiber increased with the increase of voltage applied on the two terminals of nano-fiber. The electrochemical inactive PPy nano-fiber might be used as a nano-fiber switching diode. Both Au/electrochemically active PPy and Au/electrochemically inactive PPy nano-fiber devices demonstrate rectifying behavior, and might have been used for further application as nano-rectifiers

  9. Electrochemical fabrication and electronic behavior of polypyrrole nano-fiber array devices

    Energy Technology Data Exchange (ETDEWEB)

    Ling, Liu [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Yaomin, Zhao [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Nengqin, Jia [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Qin, Zhou [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Chongjun, Zhao [Photon Craft Project, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences and Japan Science and Technology Agency, Shanghai 201800 (China); Manming, Yan [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China); Zhiyu, Jiang [Department of Chemistry, and Shanghai Key Laboratory of Molecular Catalysis and Innovative Materials, Fudan University, Shanghai 200433 (China)

    2006-05-01

    Electrochemically active Polypyrrole (PPy) nano-fiber array device was fabricated via electrochemical deposition method using aluminum anodic oxide (AAO) membrane as template. After alkaline treatment electrochemically active PPy nano-fiber lost electrochemical activity, and became electrochemically inactive PPy. The electronic properties of PPy nano-fiber array devices were measured by means of a simple method. It was found that for an indium-tin oxide/electrochemically inactive PPy nano-fiber device, the conductivity of nano-fiber increased with the increase of voltage applied on the two terminals of nano-fiber. The electrochemical inactive PPy nano-fiber might be used as a nano-fiber switching diode. Both Au/electrochemically active PPy and Au/electrochemically inactive PPy nano-fiber devices demonstrate rectifying behavior, and might have been used for further application as nano-rectifiers.

  10. Self-powered Imbibing Microfluidic Pump by Liquid Encapsulation: SIMPLE.

    Science.gov (United States)

    Kokalj, Tadej; Park, Younggeun; Vencelj, Matjaž; Jenko, Monika; Lee, Luke P

    2014-11-21

    Reliable, autonomous, internally self-powered microfluidic pumps are in critical demand for rapid point-of-care (POC) devices, integrated molecular-diagnostic platforms, and drug delivery systems. Here we report on a Self-powered Imbibing Microfluidic Pump by Liquid Encapsulation (SIMPLE), which is disposable, autonomous, easy to use and fabricate, robust, and cost efficient, as a solution for self-powered microfluidic POC devices. The imbibition pump introduces the working liquid which is sucked into a porous material (paper) upon activation. The suction of the working liquid creates a reduced pressure in the analytical channel and induces the sequential sample flow into the microfluidic circuits. It requires no external power or control and can be simply activated by a fingertip press. The flow rate can be programmed by defining the shape of utilized porous material: by using three different paper shapes with circular section angles 20°, 40° and 60°, three different volume flow rates of 0.07 μL s(-1), 0.12 μL s(-1) and 0.17 μL s(-1) are demonstrated at 200 μm × 600 μm channel cross-section. We established the SIMPLE pumping of 17 μL of sample; however, the sample volume can be increased to several hundreds of μL. To demonstrate the design, fabrication, and characterization of SIMPLE, we used a simple, robust and cheap foil-laminating fabrication technique. The SIMPLE can be integrated into hydrophilic or hydrophobic materials-based microfluidic POC devices. Since it is also applicable to large-scale manufacturing processes, we anticipate that a new chapter of a cost effective, disposable, autonomous POC diagnostic chip is addressed with this technical innovation.

  11. Photon and neutron doses of the personnel using moisture and density measurement devices

    Energy Technology Data Exchange (ETDEWEB)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V. [Greek Atomic Energy Commission, Agia Paraskevi, Attiki, 60092 (Greece)

    2006-07-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a {sup 137}Cs source for density measurements and an {sup 241}Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  12. Photon and neutron doses of the personnel using moisture and density measurement devices

    International Nuclear Information System (INIS)

    Carinou, E.; Papadomarkaki, E.; Tritakis, P.; Hourdakis, C.I.; Kamenopoulou, V.

    2006-01-01

    The objective of this study is to present the evolution of the photon doses received by the workers who use mobile devices for measuring the moisture and the density in various materials and to estimate the neutron doses. The workers employed in more than 30 construction companies in Greece were 76 in 2004. The devices used for that purpose incorporate a 137 Cs source for density measurements and an 241 Am-Be source for moisture measurements of soil, asphalt or concrete. Photon and neutron measurements were performed occasionally during the on site inspections. The results of the measurements showed that the photon and neutron dose rates were not negligible. The workers were monitored for photon radiation using film badges (Kodak Type 2, Holder NRPB type) till the year 2000 and then TLD badges issued by the Greek Atomic Energy Commission (GAEC), on a monthly basis. Since the neutron dose rates measured by a rem-meter were not so high, no neutron dosemeters were issued for them. Their personal dose equivalent data for photons are kept in the National Dose Registry Information System (N.D.R.I.S.) in G.A.E.C. and were used for statistical analysis for the period from 1997 till 2004. As far as the neutrons are concerned, a Monte Carlo code was used to simulate the measuring devices and the working positions in order to calculate the neutron individual doses. (authors)

  13. The Necessary Death of the Block Device Interface

    DEFF Research Database (Denmark)

    Bjørling, Matias; Bonnet, Philippe; Bouganim, Luc

    2013-01-01

    that this option amounts to building on quicksand. We illustrate our point by debunking some popular myths about flash devices and by pointing out mistakes in the papers we have published throughout the years. The second option is to abandon the simple abstraction of the block device interface and reconsider how...... device interface. This is the mainstream option both in industry and academia. This leaves the storage and OS communities with the responsibility to deal with the complexity introduced by SSDs in the hope that they will provide us with a robust, yet simple, performance model. In this paper, we show...

  14. An unattended device for high-voltage sampling and passive measurement of thoron decay products

    Energy Technology Data Exchange (ETDEWEB)

    Gierl, Stefanie; Meisenberg, Oliver, E-mail: oliver.meisenberg@helmholtz-muenchen.de; Wielunski, Marek; Tschiersch, Jochen [Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Radiation Protection, Ingolstädter Landstr. 1, 85764 Neuherberg (Germany); Haninger, Thomas [Helmholtz Zentrum München, German Research Center for Environmental Health, Auswertungsstelle für Strahlendosimeter, Otto-Hahn-Ring 6, 81739 München (Germany)

    2014-02-15

    An integrating measurement device for the concentration of airborne thoron decay products was designed and calibrated. It is suitable for unattended use over up to several months also in inhabited dwellings. The device consists of a hemispheric capacitor with a wire mesh as the outer electrode on ground potential and the sampling substrates as the inner electrode on +7.0 kV. Negatively charged and neutral thoron decay products are accelerated to and deposited on the sampling substrates. As sampling substrates, CR39 solid-state nuclear track detectors are used in order to record the alpha decay of the sampled decay products. Nuclide discrimination is achieved by covering the detectors with aluminum foil of different thickness, which are penetrated only by alpha particles with sufficient energy. Devices of this type were calibrated against working level monitors in a thoron experimental house. The sensitivity was measured as 9.2 tracks per Bq/m{sup 3} × d of thoron decay products. The devices were used over 8 weeks in several houses built of earthen material in southern Germany, where equilibrium equivalent concentrations of 1.4–9.9 Bq/m{sup 3} of thoron decay products were measured.

  15. The Total Deviation Index estimated by Tolerance Intervals to evaluate the concordance of measurement devices

    Directory of Open Access Journals (Sweden)

    Ascaso Carlos

    2010-04-01

    Full Text Available Abstract Background In an agreement assay, it is of interest to evaluate the degree of agreement between the different methods (devices, instruments or observers used to measure the same characteristic. We propose in this study a technical simplification for inference about the total deviation index (TDI estimate to assess agreement between two devices of normally-distributed measurements and describe its utility to evaluate inter- and intra-rater agreement if more than one reading per subject is available for each device. Methods We propose to estimate the TDI by constructing a probability interval of the difference in paired measurements between devices, and thereafter, we derive a tolerance interval (TI procedure as a natural way to make inferences about probability limit estimates. We also describe how the proposed method can be used to compute bounds of the coverage probability. Results The approach is illustrated in a real case example where the agreement between two instruments, a handle mercury sphygmomanometer device and an OMRON 711 automatic device, is assessed in a sample of 384 subjects where measures of systolic blood pressure were taken twice by each device. A simulation study procedure is implemented to evaluate and compare the accuracy of the approach to two already established methods, showing that the TI approximation produces accurate empirical confidence levels which are reasonably close to the nominal confidence level. Conclusions The method proposed is straightforward since the TDI estimate is derived directly from a probability interval of a normally-distributed variable in its original scale, without further transformations. Thereafter, a natural way of making inferences about this estimate is to derive the appropriate TI. Constructions of TI based on normal populations are implemented in most standard statistical packages, thus making it simpler for any practitioner to implement our proposal to assess agreement.

  16. A novel wearable device for continuous, non-invasion blood pressure measurement.

    Science.gov (United States)

    Xin, Qin; Wu, Jianping

    2017-08-01

    In this paper, we have developed a wearable cuffless device for daily blood pressure (BP) measurement. We incorporated the light based sensor and other hard wares in a small volume for BP detection. With optimized algorithm, the real-time BP reading could be achieved, the data could be presented in the screen and be transmitted by internet of things (IoT) for history data comparison and multi-terminal viewing. Thus, further analysis provides the probability for diet or sports suggestion and alarm. We have measured BP from more than 60 subjects, compare to traditional mercury blood pressure meter, no obvious error in both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are detected. Such device can be used for continues non-invasion BP detection, and further data docking and health analysis could be achieved. Copyright © 2017. Published by Elsevier Ltd.

  17. Device for determining element contents of lignite mass flows by activation analysis

    International Nuclear Information System (INIS)

    Goeldner, R.; Maul, E.; Rose, W.; Wagner, D.

    1987-01-01

    A simple device is presented, apt for continuous operation, to determine the element contents of bulk goods of flowable materials with a suitable granularity, in particular of lignite mass flows to assess the coal quality. Several kilograms of samples can be reproducibly dosed and homogeneously activated by a device consisting of a shielding container with activation chamber and radiation source, a measuring unit with detectors, and a source container, and characterized by a blade wheel in the activation chamber which causes the dosing and homogeneous activation of the sample

  18. A Simple Method to Measure Nematodes' Propulsive Thrust and the Nematode Ratchet.

    Science.gov (United States)

    Bau, Haim; Yuan, Jinzhou; Raizen, David

    2015-11-01

    Since the propulsive thrust of micro organisms provides a more sensitive indicator of the animal's health and response to drugs than motility, a simple, high throughput, direct measurement of the thrust is desired. Taking advantage of the nematode C. elegans being heavier than water, we devised a simple method to determine the propulsive thrust of the animals by monitoring their velocity when swimming along an inclined plane. We find that the swimming velocity is a linear function of the sin of the inclination angle. This method allows us to determine, among other things, the animas' propulsive thrust as a function of genotype, drugs, and age. Furthermore, taking advantage of the animals' inability to swim over a stiff incline, we constructed a sawteeth ratchet-like track that restricts the animals to swim in a predetermined direction. This research was supported, in part, by NIH NIA Grant 5R03AG042690-02.

  19. Information technology made simple

    CERN Document Server

    Carter, Roger

    1991-01-01

    Information Technology: Made Simple covers the full range of information technology topics, including more traditional subjects such as programming languages, data processing, and systems analysis. The book discusses information revolution, including topics about microchips, information processing operations, analog and digital systems, information processing system, and systems analysis. The text also describes computers, computer hardware, microprocessors, and microcomputers. The peripheral devices connected to the central processing unit; the main types of system software; application soft

  20. Temperature measurement and control

    CERN Document Server

    Leigh, JR

    1988-01-01

    This book treats the theory and practice of temperature measurement and control and important related topics such as energy management and air pollution. There are no specific prerequisites for the book although a knowledge of elementary control theory could be useful. The first half of the book is an application oriented survey of temperature measurement techniques and devices. The second half is concerned mainly with temperature control in both simple and complex situations.

  1. Simple Neuron-Fuzzy Tool for Small Control Devices

    DEFF Research Database (Denmark)

    Madsen, Per Printz

    2008-01-01

    Small control computers, running a kind of Fuzzy controller, are more and more used in many systems from household machines to large industrial systems. The purpose of this paper is firstly to describe a tool that is easy to use for implementing self learning Fuzzy systems, that can be executed...... can be described by four different kinds of membership functions. The output fuzzyfication is based on singletons. The rule base can be written in a natural language. The result of the learning is a new version of the Fuzzy system described in the FuNNy language. A simple shower control example...... is shown.  This example shows that FuNNy is able to control the shower and that the learning is able to optimize the Fuzzy system....

  2. Development of high impedance measurement system for water leakage detection in implantable neuroprosthetic devices.

    Science.gov (United States)

    Yousif, Aziz; Kelly, Shawn K

    2016-08-01

    There has been a push for a greater number of channels in implantable neuroprosthetic devices; but, that number has largely been limited by current hermetic packaging technology. Microfabricated packaging is becoming reality, but a standard testing system is needed to prepare these devices for clinical trials. Impedance measurements of electrodes built into the packaging layers may give an early warning of device failure and predict device lifetime. Because the impedance magnitudes of such devices can be on the order of gigaohms, a versatile system was designed to accommodate ultra-high impedances and allow future integrated circuit implementation in current neural prosthetic technologies. Here we present the circuitry, control software, and preliminary testing results of our designed system.

  3. Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment.

    Science.gov (United States)

    Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang

    2013-09-01

    We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

  4. Optical Regeneration and Noise in Semiconductor Devices

    DEFF Research Database (Denmark)

    Öhman, Filip

    2005-01-01

    In this report all-optical 2R-regeneration in optical communication systems is investigated. A simple regenerator device based on concatenated semiconductor optical amplifiers (SOAs) and electro absorbers (EAs) is introduced and examined. Experiments show that the monolithic SOA-EA 2R-regenerator......In this report all-optical 2R-regeneration in optical communication systems is investigated. A simple regenerator device based on concatenated semiconductor optical amplifiers (SOAs) and electro absorbers (EAs) is introduced and examined. Experiments show that the monolithic SOA-EA 2R...

  5. Proof of Concept: Design and Initial Evaluation of a Device to Measure Gastrointestinal Transit Time.

    Science.gov (United States)

    Wagner, Robert H; Savir-Baruch, Bital; Halama, James R; Venu, Mukund; Gabriel, Medhat S; Bova, Davide

    2017-09-01

    Chronic constipation and gastrointestinal motility disorders constitute a large part of a gastroenterology practice and have a significant impact on a patient's quality of life and lifestyle. In most cases, medications are prescribed to alleviate symptoms without there being an objective measurement of response. Commonly used investigations of gastrointestinal transit times are currently limited to radiopaque markers or electronic capsules. Repeated use of these techniques is limited because of the radiation exposure and the significant cost of the devices. We present the proof of concept for a new device to measure gastrointestinal transit time using commonly available and inexpensive materials with only a small amount of radiotracer. Methods: We assembled gelatin capsules containing a 67 Ga-citrate-radiolabeled grain of rice embedded in paraffin for use as a point-source transit device. It was tested for stability in vitro and subsequently was given orally to 4 healthy volunteers and 10 patients with constipation or diarrhea. Imaging was performed at regular intervals until the device was excreted. Results: The device remained intact and visible as a point source in all subjects until excretion. When used along with a diary of bowel movement times and dates, the device could determine the total transit time. The device could be visualized either alone or in combination with a barium small-bowel follow-through study or a gastric emptying study. Conclusion: The use of a point-source transit device for the determination of gastrointestinal transit time is a feasible alternative to other methods. The device is inexpensive and easy to assemble, requires only a small amount of radiotracer, and remains inert throughout the gastrointestinal tract, allowing for accurate determination of gastrointestinal transit time. Further investigation of the device is required to establish optimum imaging parameters and reference values. Measurements of gastrointestinal transit time

  6. The Development of 1Balance: A Connected Medical Device for Measuring Human Balance

    Directory of Open Access Journals (Sweden)

    Heikki Sjöman

    2018-05-01

    Full Text Available Prototyping (iterative loops of design–build–test is a proven method of efficiently developing new products. Developing products not only quickly, but that are also fit for purpose, implies engaging the end users and iterating the technology at hand. However, there is currently little research on how engineering design can approach developing connected devices. The purpose of this paper is to distinguish and discuss design approaches that are suitable for connected devices. Internet of Things devices consist of both the physical products themselves and the data that is coming out of the products, which we define as the external and internal data, respectively. They both can be prototyped separately, but since the data acquired can influence the design of the device and vice versa, we propose to link these two together in the product development process. This issue becomes more apparent when designing networks of sensors, e.g., for complex artificial intelligence (AI databases. We explain the principle by describing the development of 1Balance through six different prototypes for human balance measurement. Technologically quantifying balance is an underused approach for objectively evaluating the state of a human’s performance. The authors have developed a mobile application for monitoring balance as a physiological signal (amount of sway via a compact wireless inertial measurement unit (IMU sensor strapped to the body of the subject for the duration of the measurement. We describe the design process for developing this connected medical device, as well as how the acquired data was used to improve the design of the product. In conclusion, we propose conceptually connecting the external and internal data prototyping loops.

  7. Research trend in thermally stimulated current method for development of materials and devices in Japan

    Science.gov (United States)

    Iwamoto, Mitsumasa; Taguchi, Dai

    2018-03-01

    Thermally stimulated current (TSC) measurement is widely used in a variety of research fields, i.e., physics, electronics, electrical engineering, chemistry, ceramics, and biology. TSC is short-circuit current that flows owing to the displacement of charges in samples during heating. TSC measurement is very simple, but TSC curves give very important information on charge behaviors. In the 1970s, TSC measurement contributed greatly to the development of electrical insulation engineering, semiconductor device technology, and so forth. Accordingly, the TSC experimental technique and its analytical method advanced. Over the past decades, many new molecules and advanced functional materials have been discovered and developed. Along with this, TSC measurement has attracted much attention in industries and academic laboratories as a way of characterizing newly discovered materials and devices. In this review, we report the latest research trend in the TSC method for the development of materials and devices in Japan.

  8. A simple way of characterizing X-ray downwards-deflecting mirror-bender assemblies using the long trace profiler

    International Nuclear Information System (INIS)

    Assoufid, L.; Her, P.

    1999-01-01

    A simple device composed of a modular double-pentaprism system that enables the long trace profiler (LTP) to measure mirrors in nonconventional ways, i.e., in the vertical-downward and sideways positions, has been devised and implemented in the Advanced Photon Source (APS) long trace profiler (LTP II). The systems is very useful in calibrating mirror-bender assemblies. This paper describes the system and gives results of measurements performed with it on a mirror used at the APS

  9. Reactor water level measuring device

    International Nuclear Information System (INIS)

    Kuroki, Reiji; Asano, Tamotsu.

    1996-01-01

    A condensation vessel is connected to the upper portion of a reactor pressure vessel by way of a pipeline. The lower portion of the condensation vessel is connected to a low pressure side of a differential pressure transmission device by way of a reference leg pipeline. The high pressure side of the differential pressure transmission device is connected to the lower portion of the pressure vessel by way of a pipeline. The condensation vessel is equipped with a temperature sensor. When a temperature of a gas phase portion in the condensation vessel is lowered below a predetermined level, and incondensible gases in the condensation vessel starts to be dissolved in water, signals are sent from the temperature sensor to a control device and a control valve is opened. With such a constitution, CRD driving water flows into the condensation vessel, and water in which gases at the upper portion of the condensation vessel is dissolved flows into the pressure vessel by way of a pipeline. Then, gases dissolved in a reference water column in the reference leg pipeline are eliminated and the value of a reference water pressure does not change even upon abrupt lowering of pressure. (I.N.)

  10. Fermentation, Respiration & Enzyme Specificity: A Simple Device & Key Experiments with Yeast.

    Science.gov (United States)

    Reinking, Larry N.; And Others

    1994-01-01

    Using graphs and diagrams, the authors describe a simple fermentation chamber and provide key experiments that can be used in the classroom to give students meaningful insight into metabolic processes. (ZWH)

  11. Validation of a Piezoelectric Sensor Array-Based Device for Measurement of Carotid-Femoral Pulse Wave Velocity: The Philips Prototype.

    Science.gov (United States)

    Xu, Shao-Kun; Hong, Xiang-Fei; Cheng, Yi-Bang; Liu, Chang-Yuan; Li, Yan; Yin, Bin; Wang, Ji-Guang

    2018-03-01

    Multiple piezoelectric pressure mechanotransducers topologized into an array might improve efficiency and accuracy in collecting arterial pressure waveforms for measurement of pulse wave velocity (PWV). In the present study, we validated a piezoelectric sensor array-based prototype (Philips) against the validated and clinically widely used Complior device (Alam Medical). We recruited 33 subjects with a wide distribution of PWV. For the validation, PWV was measured sequentially with the Complior device (four times) and the Philips prototype (three times). With the 99 paired PWV values, we investigated the agreement between the Philips prototype and the Complior device using Pearson correlation analysis and Bland-Altman plot. We also performed analysis on the determinants and reproducibility of PWV measured with both devices. The correlation coefficient for PWV measured with the two devices was 0.92 ( p prototype slightly overestimated PWV by 0.24 (± 2 standard deviations, ± 1.91) m/s, especially when PWV was high. The correlation coefficient between the difference and the average of the Philips and Complior measurements was 0.21 ( p = 0.035). Nonetheless, they had similar determinants. Age, mean arterial pressure, and sex altogether explained 81.6 and 83.9% of the variance of PWV values measured with the Philips prototype and Complior device, respectively. When the two extremes of the three PWV values measured with the Philips prototype and the Complior device were investigated, the coefficients of variation were 8.26 and 3.26%, respectively. Compared with the Complior device, the Philips prototype had similar accuracy, determinants, and reproducibility in measuring PWV.

  12. DATA PROCESSING FROM THE MEASURING DEVICE BALLBAR QC20

    Directory of Open Access Journals (Sweden)

    Matúš Košinár

    2014-03-01

    Full Text Available The paper presents an innovative method of data processing from the measurement device – Ballbar QC20W. It was created with a program for data transformation (Visual Basic.NET and it used Fourier transformation. The paper deals with the measuring method of CNC machine tools using Ballbar QC20W. There is an influence between qualitative parameters of machine tools and qualitative parameters of products (tolerances, roughness, etc.. It is very important to hold the stability of qualitative parameters of products as a key factor of production quality. Therefore, is also important to evaluate the accuracy of machine tools and make prediction of possible accuracy.

  13. Nuclear reactor fuel assembly grid measuring method and device

    International Nuclear Information System (INIS)

    Fink, D.J.; Cooper, F.W. Jr.

    1987-01-01

    A device is described for remotely measuring a dimension of a workpiece, comprising: (a) first means for measuring the dimension of the workpiece; (b) second means for limiting the force exerted by the first means against the workpiece; (c) third means connected to the first means for moving the first means in the X, Y, Z axes simultaneously relative to the workpiece; (d) fourth means for limiting the force exerted by the third means moving the first means in the X, Y, Z axes; and (e) fifth means remote from the workpiece for monitoring and controlling the movement of the first means relative to the workpiece

  14. A simple procedure for measuring pharyngeal sensitivity: a contribution to the diagnosis of sleep apnoea

    OpenAIRE

    Dematteis, M; Levy, P; Pepin, J

    2005-01-01

    Background: Patients with severe apnoea may have an impaired pharyngeal dilating reflex related to decreased pharyngeal sensitivity. The accuracy of a simple new procedure to measure pharyngeal sensitivity and to diagnose sleep disordered breathing (SDB) was investigated.

  15. Simple solution-processed CuO{sub X} as anode buffer layer for efficient organic solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Wenfei [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Institute of Hybrid Materials, The Growing Base for State Key Laboratory, Qingdao University, 308 Ningxia Road, Qingdao 266071 (China); Yang, Chunpeng [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Bao, Xichang, E-mail: baoxc@qibebt.ac.cn [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Sun, Liang; Wang, Ning [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Tang, Jianguo [Institute of Hybrid Materials, The Growing Base for State Key Laboratory, Qingdao University, 308 Ningxia Road, Qingdao 266071 (China); Chen, Weichao [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China); Yang, Renqiang, E-mail: yangrq@qibebt.ac.cn [CAS Key Laboratory of Bio-based Materials, Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, 189 Songling Road, Qingdao 266101 (China)

    2015-10-15

    Graphical abstract: - Highlights: • Simple solution-processed CuO{sub X} hole transport layer for efficient organic solar cell. • Good photovoltaic performances as hole transport layer in OSCs with P3HT and PBDTTT-C as donor materials. • The device with CuO{sub X} as hole transport layer shows great improved stability compared with that of device with PEDOT:PSS as hole transport layer. - Abstract: A simple, solution-processed ultrathin CuO{sub X} anode buffer layer was fabricated for high performance organic solar cells (OSCs). XPS measurement demonstrated that the CuO{sub X} was the composite of CuO and Cu{sub 2}O. The CuO{sub X} modified ITO glass exhibit a better surface contact with the active layer. The photovoltaic performance of the devices with CuO{sub X} layer was optimized by varying the thickness of CuO{sub X} films through changing solution concentration. With P3HT:PC{sub 61}BM as the active layer, we demonstrated an enhanced PCE of 4.14% with CuO{sub X} anode buffer layer, compared with that of PEDOT:PSS layer. The CuO{sub X} layer also exhibits efficient photovoltaic performance in devices with PBDTTT-C:PC{sub 71}BM as the active layer. The long-term stability of CuO{sub X} device is better than that of PEDOT:PSS device. The results indicate that the easy solution-processed CuO{sub X} film can act as an efficient anode buffer layer for high-efficiency OSCs.

  16. Design and testing of a chamber device to measure organic vapor fluxes from the unsaturated zone under natural conditions

    International Nuclear Information System (INIS)

    Tillman, F.D.; Choi, J-W.; Smith, J.A.

    2002-01-01

    As the difficulty and expense of achieving water quality standards at contaminated sites becomes more apparent, the U.S. Environmental Protection Agency is taking a closer look at natural attenuation processes for selected sites. To determine if a site has potential for natural attenuation, all natural processes affecting the fate and transport of volatile organic compounds (VOCs) in the subsurface must be identified and quantified. This research addresses the quantification of air-phase VOCs leaving the subsurface and entering the atmosphere, both through diffusion and soil-gas advection caused by barometric pumping. A simple, easy-to-use, and inexpensive device for measuring VOC flux under natural conditions was designed, constructed and tested both in a controlled laboratory environment and in a natural field setting. Design parameters for the chamber were selected using continuously stirred tank reactor (CSTR)-equation based modeling under several flux inputs. The final chamber design performs at greater than 95% efficiency for the simulated cases. Laboratory testing of the flux chamber under both diffusion and advection transport conditions was performed in a device constructed to simulate the unsaturated zone. Results indicate an average flux measurement accuracy of 83% over 3 orders of magnitude for diffusion-only fluxes and 94% for combined advection-diffusion fluxes. A field test of the chamber was performed and results compared with predictions made by a 1-dimensional unsaturated zone flow and transport model whose calibration and parameters were obtained from data collected at the site. Fluxes measured directly by the chamber were generally in good agreement with the fluxes calculated from the calibrated flow-and-transport model. (author)

  17. An Industrial Radipgraphy Exposure Device Based on Measurement of Transmitted Gamma-Ray Intensity

    International Nuclear Information System (INIS)

    Polee, C.; Chankow, N.; Srisatit, S.; Thong-Aram, D.

    2014-01-01

    In film radiography, underexposure and overexposure may happen particularly when lacking knowledge of specimen material and hollowness. This paper describes a method and a device for determining exposure in industrial gamma-ray radiography based on quick measurement of transmitted gamma-ray intensity with a D3372 Hamamatsu small GM tube. Application software is developed for Android mobile phone to remotely control the device and to display the counting data via Bluetooth. Prior to placing film, the device is placed behind the specimen to be radiographed to determine the exposure time from the transmitted intensity which is independent on source activity, source-to-film distance, specimen thickness and kind of material. The developed technique and device make radiographic process economic, convenient and more reliable.

  18. A harmonic coil measurement system based on a dynamic signal acquisition device

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, J.X., E-mail: zhoujx@ihep.ac.c [Institute of High Energy Physics, P.O. Box 918-9, Beijing 100049 (China); Li, L.; Yin, B.G.; Deng, C.D.; Kang, W.; Chen, Y.; Zhang, Z.; Fu, S.N. [Institute of High Energy Physics, P.O. Box 918-9, Beijing 100049 (China)

    2010-12-21

    A new harmonic coil measurement system based on a dynamic signal acquisition device has been successfully developed to check the field quality of the quadrupole magnet for the CSNS/RCS, which operates at the 25 Hz excitation cycle with a DC bias. It was designed to acquire multiple channels of data with a wide dynamic range of input signals, which are typically generated by a harmonic coil and an encoder. A dedicated algorithm was developed in LabView code to identify over specified intervals, synchronized to the coil's rotation in the magnetic field. Through full integration of hardware and software, the traditional device (PDI 5025) is replaced successfully. This paper summarizes the characteristics of the system and presents the results of DC measurements.

  19. A simple, high performance Thomson scattering diagnostic for high temperature plasma research

    International Nuclear Information System (INIS)

    Hartog, D.J.D.; Cekic, M.

    1994-02-01

    This Thomson scattering diagnostic is used to measure the electron temperature and density of the plasma in the MST reversed-field pinch, a magnetic confinement fusion research device. This diagnostic system is unique for its type in that it combines high performance with simple design and low cost components. In the design of this instrument, careful attention was given to the suppression of stray laser line light with simple and effective beam dumps, viewing dumps, aperatures, and a holographic edge filter. This allows the use of a single grating monochromator for dispersion of the Thomson scattered spectrum onto the microchannel plate detector. Alignment and calibration procedures for the laser beam delivery system, the scattered light collection system, and the spectrometer and detector are described. A sample Thomson scattered spectrum illustrates typical data

  20. Design and construction of safety devices utilizing methods of measurement and control engineering

    Energy Technology Data Exchange (ETDEWEB)

    Greiner, B; Weidlich, S

    1982-08-01

    This article considers a proposed concept for the design and construction of measurement and control devices for the safety of chemical plants with the aim of preventing danger to persons and the environment and damage. Such measurement and control devices are generally employed when primary measures adopted for plant safety, such as safety valves, collection vessels, etc. are not applicable or insufficient by themselves. The concept regards the new sheet no. 3 of the VDI/VDE code draft 2180 ''Safety of chemical engineering plant'' and proposes a further subdivision of class A into safety classes A0, A1, and A2. Overall, it is possible, on the basis of the measures for raising the availability of measurement and control equipment which are presented in this article, to make selection appropriate to the potential danger involved. The proposed procedure should not, however, be regarded as a rigid scheme but rather as leading to a systematic view and supporting decisions resting on sound operating experience.

  1. Using Simple Harmonic Motion to Follow the Galilean Moons--Testing Kepler's Third Law on a Small System

    Science.gov (United States)

    de Moraes, I. G.; Pereira, J. A. M.

    2009-01-01

    The motion of the four Galilean moons of Jupiter is studied in this work. The moons had their positions with respect to the centre of the planet measured during one week of observation by means of telescopic charge coupled device images. It is shown that their movement can be well described as a simple harmonic motion. The revolution period and…

  2. Reliability of measuring pelvic floor elevation with a diagnostic ultrasonic imaging device

    OpenAIRE

    Ubukata, Hitomi; Maruyama, Hitoshi; Huo, Ming

    2015-01-01

    [Purpose] The purpose of this study was to investigate the reliability of measuring the amount of pelvic floor elevation during pelvic and abdominal muscle contraction with a diagnostic ultrasonic imaging device. [Subjects] The study group comprised 11 healthy women without urinary incontinence or previous birth experience. [Methods] We measured the displacement elevation of the bladder base during contraction of the abdominal and pelvic floor muscles was measured using a diagnostic ultrasoni...

  3. A simple quality assurance test tool for the visual verification of light and radiation field congruent using electronic portal images device and computed radiography

    Directory of Open Access Journals (Sweden)

    Njeh Christopher F

    2012-03-01

    Full Text Available Abstract Background The radiation field on most megavoltage radiation therapy units are shown by a light field projected through the collimator by a light source mounted inside the collimator. The light field is traditionally used for patient alignment. Hence it is imperative that the light field is congruent with the radiation field. Method A simple quality assurance tool has been designed for rapid and simple test of the light field and radiation field using electronic portal images device (EPID or computed radiography (CR. We tested this QA tool using Varian PortalVision and Elekta iViewGT EPID systems and Kodak CR system. Results Both the single and double exposure techniques were evaluated, with double exposure technique providing a better visualization of the light-radiation field markers. The light and radiation congruency could be detected within 1 mm. This will satisfy the American Association of Physicists in Medicine task group report number 142 recommendation of 2 mm tolerance. Conclusion The QA tool can be used with either an EPID or CR to provide a simple and rapid method to verify light and radiation field congruence.

  4. Characterization of thermoelectric devices by laser induced Seebeck electromotive force (LIS-EMF) measurement

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Luis-David Patino [Universite de Bordeaux 1, Centre de Physique Moleculaire Optique et Hertzienne, 351, cours de la liberation, 33405 Talence (France); Dilhaire, Stefan [Universite de Bordeaux 1, Centre de Physique Moleculaire Optique et Hertzienne, 351, cours de la liberation, 33405 Talence (France); Grauby, Stephane [Universite de Bordeaux 1, Centre de Physique Moleculaire Optique et Hertzienne, 351, cours de la liberation, 33405 Talence (France); Salhi, M Amine [Universite de Bordeaux 1, Centre de Physique Moleculaire Optique et Hertzienne, 351, cours de la liberation, 33405 Talence (France); Ezzahri, Younes [Universite de Bordeaux 1, Centre de Physique Moleculaire Optique et Hertzienne, 351, cours de la liberation, 33405 Talence (France); Claeys, Wilfrid [Universite de Bordeaux 1, Centre de Physique Moleculaire Optique et Hertzienne, 351, cours de la liberation, 33405 Talence (France); Batsale, Jean-Christophe [Laboratoire TREFLE, Esplanade des Arts et Metiers, 33405 Talence Cedex (France)

    2005-05-21

    An in-depth study related to a new method of characterizing properties in thermoelectrics is proposed in this paper. This technique is appropriate for single or multi-layered thermoelectric devices. A modulated laser beam is used as a heater in order to generate a Seebeck electromotive force (EMF). The laser beam, line shaped, can be focused at any location along the sample surface, allowing spatially resolved measurements. Seebeck EMF measurements, associated with a versatile model based on the thermal quadrupoles method, allow determination of the sample Seebeck EMF profile and identifying of the sample thermal contact resistances, and should be useful for identification of devices and material thermoelectric properties.

  5. On the problem of linear calibration for a reading system of measuring devices

    International Nuclear Information System (INIS)

    Shigaev, V.N.

    1978-01-01

    The problem of gauging the frame of reference of a measuring device has been giVen a general approach which consists in finding an approximated inverse transformation on the basis of a partial diagram of a direct transformation which is defined on a given set, D, within the limits of the device measuring range. The following linear models of frame of reference are discussed: a general oblique system; a rectangular system with axes having different scales; a rectangular system with similar scale axes. Linear distortion for two rectangular models has been assessed. It is pointed out that the best approximation to the reduction operation should be found over the D set

  6. Characterization of thermoelectric devices by laser induced Seebeck electromotive force (LIS-EMF) measurement

    International Nuclear Information System (INIS)

    Lopez, Luis-David Patino; Dilhaire, Stefan; Grauby, Stephane; Salhi, M Amine; Ezzahri, Younes; Claeys, Wilfrid; Batsale, Jean-Christophe

    2005-01-01

    An in-depth study related to a new method of characterizing properties in thermoelectrics is proposed in this paper. This technique is appropriate for single or multi-layered thermoelectric devices. A modulated laser beam is used as a heater in order to generate a Seebeck electromotive force (EMF). The laser beam, line shaped, can be focused at any location along the sample surface, allowing spatially resolved measurements. Seebeck EMF measurements, associated with a versatile model based on the thermal quadrupoles method, allow determination of the sample Seebeck EMF profile and identifying of the sample thermal contact resistances, and should be useful for identification of devices and material thermoelectric properties

  7. A simple microwave technique for plasma density measurement using frequency modulation

    International Nuclear Information System (INIS)

    Bora, D.; Jayakumar, R.; Vijayashankar, M.K.

    1984-01-01

    A simple method of determining the phase variation unambiguously during microwave interferometric measurement is described. The frequency of the Klystron source is modulated with the help of staircase voltage pulse. The height of each stair is adjusted such that the corresponding phase shift in the test branch with an additional path length is 90 0 . Signals, proportional to cosine and sine of the phase shift due to plasma, can be generated in the same channel and plasma density information can be inferred. The microwave hardware remains the same as in conventional interferometry and the cost of such a scheme is low. (author)

  8. Validity and Reliability of the PUSH Wearable Device to Measure Movement Velocity During the Back Squat Exercise.

    Science.gov (United States)

    Balsalobre-Fernández, Carlos; Kuzdub, Matt; Poveda-Ortiz, Pedro; Campo-Vecino, Juan Del

    2016-07-01

    Balsalobre-Fernández, C, Kuzdub, M, Poveda-Ortiz, P, and Campo-Vecino, Jd. Validity and reliability of the PUSH wearable device to measure movement velocity during the back squat exercise. J Strength Cond Res 30(7): 1968-1974, 2016-The purpose of this study was to analyze the validity and reliability of a wearable device to measure movement velocity during the back squat exercise. To do this, 10 recreationally active healthy men (age = 23.4 ± 5.2 years; back squat 1 repetition maximum [1RM] = 83 ± 8.2 kg) performed 3 repetitions of the back squat exercise with 5 different loads ranging from 25 to 85% 1RM on a Smith Machine. Movement velocity for each of the total 150 repetitions was simultaneously recorded using the T-Force linear transducer (LT) and the PUSH wearable band. Results showed a high correlation between the LT and the wearable device mean (r = 0.85; standard error of estimate [SEE] = 0.08 m·s) and peak velocity (r = 0.91, SEE = 0.1 m·s). Moreover, there was a very high agreement between these 2 devices for the measurement of mean (intraclass correlation coefficient [ICC] = 0.907) and peak velocity (ICC = 0.944), although a systematic bias between devices was observed (PUSH peak velocity being -0.07 ± 0.1 m·s lower, p ≤ 0.05). When measuring the 3 repetitions with each load, both devices displayed almost equal reliability (Test-retest reliability: LT [r = 0.98], PUSH [r = 0.956]; ICC: LT [ICC = 0.989], PUSH [ICC = 0.981]; coefficient of variation [CV]: LT [CV = 4.2%], PUSH [CV = 5.0%]). Finally, individual load-velocity relationships measured with both the LT (R = 0.96) and the PUSH wearable device (R = 0.94) showed similar, very high coefficients of determination. In conclusion, these results support the use of an affordable wearable device to track velocity during back squat training. Wearable devices, such as the one in this study, could have valuable practical applications for strength and conditioning coaches.

  9. Device to investigate samples by means of flameless atomic absorption measurement

    International Nuclear Information System (INIS)

    Sperling, K.R.

    1977-01-01

    An improvement on a device to investigate samples by means of flameless atomic absorption measurement is suggested in which one aims to produce a most complete possible atomic clond from the sample to be investigated within the sample space defined by the beam bundle, through which the measuring beam bundle is passed. According to the invention, the tubular sample space should be closed by an optically penetrable window on one side. (RW) [de

  10. Sound exposure measurements using hearing-aid technology

    DEFF Research Database (Denmark)

    Jensen, Simon Boelt; Drastrup, Mads; Morales, Esteban Chávez

    2016-01-01

    scenarios. The purpose of this work is to document the use of a modified behind-the-ear (BTE) hearing-aid as a portable sound pressure level (SPL) meter. In order to obtain sound level measurements with a BTE device comparable to sound field values that can be used with existing risk assessment strategies...... levels of sound exposures are experienced in modern society in many different situations such as attending concerts, sport events and others. This leads to an interest in measurement devices which are discreet and simple to use, in order to assess sound exposures encountered in typical daily life......, differences due to microphone positions and the presence of a person in the measurement must be taken into account. The present study presents measurements carried out to document the characteristics of the BTE device, using the same framework presented in the ISO 11904 standard series. The responses...

  11. Multi-party Measurement-Device-Independent Quantum Key Distribution Based on Cluster States

    Science.gov (United States)

    Liu, Chuanqi; Zhu, Changhua; Ma, Shuquan; Pei, Changxing

    2018-03-01

    We propose a novel multi-party measurement-device-independent quantum key distribution (MDI-QKD) protocol based on cluster states. A four-photon analyzer which can distinguish all the 16 cluster states serves as the measurement device for four-party MDI-QKD. Any two out of four participants can build secure keys after the analyzers obtains successful outputs and the two participants perform post-processing. We derive a security analysis for the protocol, and analyze the key rates under different values of polarization misalignment. The results show that four-party MDI-QKD is feasible over 280 km in the optical fiber channel when the key rate is about 10- 6 with the polarization misalignment parameter 0.015. Moreover, our work takes an important step toward a quantum communication network.

  12. parameters affecting the calibration uniformity and traceability of gamma measuring devices

    International Nuclear Information System (INIS)

    Youssef, S.K.; Henaish, B.A.

    1985-01-01

    One of the problems which usually defeats the dosimetric evaluations performed by the health and safety experts is the absence of the reproducibility and accuracy of the used measuring devices systems. Furthermore, the traceability of the dose evaluation done by the users themselves are not achieved. Also the uniformity and homogeneity between the various users dosimeters and that available at specified central organization are not maintained. The present manuscript is scoping to deal with such various problems such as: a) dosimeter accuracy, b) traceability of the various users dosimeters and measuring devices. This paper also suggests a programme for the minimum facilities which are required for operating a central calibration laboratory. the responsibility of that central calibration lab., beside the linking chain between the different users and that calibration lab. are stated and discussed in detail. Furthermore, the authors experiences gained in operating the secondary standards calibration laboratory are also reviewed. 2 fig

  13. Measurements of ODAK-3K plasma device using plastic track detectors

    International Nuclear Information System (INIS)

    2010-01-01

    In this study, some testing experiments on the fusion researches with a new-constructed plasma focus (PF) device, namely ODAK-3K are reported. The device has a maximal energy input of 3 kJ and is used for both plasma and D D reaction explorations. Experiments with deuterium have shown that peak current of I p eak=39 kA flows between the electrodes at P=11.5 mbar for the operation voltage of V=14 kV. Average total neutron yield is measured around 3.3x10 5 neutrons per shot using CR-39 plastic detectors located opposite the anode inside the PF chamber

  14. Measurement-device-independent quantum communication with an untrusted source

    Science.gov (United States)

    Xu, Feihu

    2015-07-01

    Measurement-device-independent quantum key distribution (MDI-QKD) can provide enhanced security compared to traditional QKD, and it constitutes an important framework for a quantum network with an untrusted network server. Still, a key assumption in MDI-QKD is that the sources are trusted. We propose here a MDI quantum network with a single untrusted source. We have derived a complete proof of the unconditional security of MDI-QKD with an untrusted source. Using simulations, we have considered various real-life imperfections in its implementation, and the simulation results show that MDI-QKD with an untrusted source provides a key generation rate that is close to the rate of initial MDI-QKD in the asymptotic setting. Our work proves the feasibility of the realization of a quantum network. The network users need only low-cost modulation devices, and they can share both an expensive detector and a complicated laser provided by an untrusted network server.

  15. Stochastic Order Redshift Technique (SORT): a simple, efficient and robust method to improve cosmological redshift measurements

    Science.gov (United States)

    Tejos, Nicolas; Rodríguez-Puebla, Aldo; Primack, Joel R.

    2018-01-01

    We present a simple, efficient and robust approach to improve cosmological redshift measurements. The method is based on the presence of a reference sample for which a precise redshift number distribution (dN/dz) can be obtained for different pencil-beam-like sub-volumes within the original survey. For each sub-volume we then impose that: (i) the redshift number distribution of the uncertain redshift measurements matches the reference dN/dz corrected by their selection functions and (ii) the rank order in redshift of the original ensemble of uncertain measurements is preserved. The latter step is motivated by the fact that random variables drawn from Gaussian probability density functions (PDFs) of different means and arbitrarily large standard deviations satisfy stochastic ordering. We then repeat this simple algorithm for multiple arbitrary pencil-beam-like overlapping sub-volumes; in this manner, each uncertain measurement has multiple (non-independent) 'recovered' redshifts which can be used to estimate a new redshift PDF. We refer to this method as the Stochastic Order Redshift Technique (SORT). We have used a state-of-the-art N-body simulation to test the performance of SORT under simple assumptions and found that it can improve the quality of cosmological redshifts in a robust and efficient manner. Particularly, SORT redshifts (zsort) are able to recover the distinctive features of the so-called 'cosmic web' and can provide unbiased measurement of the two-point correlation function on scales ≳4 h-1Mpc. Given its simplicity, we envision that a method like SORT can be incorporated into more sophisticated algorithms aimed to exploit the full potential of large extragalactic photometric surveys.

  16. Performance Considerations for the SIMPL Single Photon, Polarimetric, Two-Color Laser Altimeter as Applied to Measurements of Forest Canopy Structure and Composition

    Science.gov (United States)

    Dabney, Philip W.; Harding, David J.; Valett, Susan R.; Vasilyev, Aleksey A.; Yu, Anthony W.

    2012-01-01

    The Slope Imaging Multi-polarization Photon-counting Lidar (SIMPL) is a multi-beam, micropulse airborne laser altimeter that acquires active and passive polarimetric optical remote sensing measurements at visible and near-infrared wavelengths. SIMPL was developed to demonstrate advanced measurement approaches of potential benefit for improved, more efficient spaceflight laser altimeter missions. SIMPL data have been acquired for wide diversity of forest types in the summers of 2010 and 2011 in order to assess the potential of its novel capabilities for characterization of vegetation structure and composition. On each of its four beams SIMPL provides highly-resolved measurements of forest canopy structure by detecting single-photons with 15 cm ranging precision using a narrow-beam system operating at a laser repetition rate of 11 kHz. Associated with that ranging data SIMPL provides eight amplitude parameters per beam unlike the single amplitude provided by typical laser altimeters. Those eight parameters are received energy that is parallel and perpendicular to that of the plane-polarized transmit pulse at 532 nm (green) and 1064 nm (near IR), for both the active laser backscatter retro-reflectance and the passive solar bi-directional reflectance. This poster presentation will cover the instrument architecture and highlight the performance of the SIMPL instrument with examples taken from measurements for several sites with distinct canopy structures and compositions. Specific performance areas such as probability of detection, after pulsing, and dead time, will be highlighted and addressed, along with examples of their impact on the measurements and how they limit the ability to accurately model and recover the canopy properties. To assess the sensitivity of SIMPL's measurements to canopy properties an instrument model has been implemented in the FLIGHT radiative transfer code, based on Monte Carlo simulation of photon transport. SIMPL data collected in 2010 over

  17. A Novel Electronic Device for Measuring Urine Flow Rate: A Clinical Investigation

    Directory of Open Access Journals (Sweden)

    Aliza Goldman

    2017-09-01

    Full Text Available Objective: Currently, most vital signs in the intensive care unit (ICU are electronically monitored. However, clinical practice for urine output (UO measurement, an important vital sign, usually requires manual recording of data that is subject to human errors. In this study, we assessed the ability of a novel electronic UO monitoring device to measure real-time hourly UO versus current clinical practice. Design: Patients were connected to the RenalSense Clarity RMS Sensor Kit with a sensor integrated within a standard sterile urinary catheter drainage tube to monitor urine flow in real time. The Clarity RMS Sensor Kit was modified to incorporate a standard urinometer (Unomedical for the nursing staff to record UO as per their standard practice. The drainage bag was placed in a container on a scientific scale (Precisa BJ to be used as the gold standard. Interventions: Nursing records for hourly UO were collected and compared with the electronically recorded UO. Sensor measurements and nursing staff manual records of UO were compared with the scale data. Setting: The study setting was the ICU of Hadassah Hospital, Jerusalem. Patients: Data from 23 patients with a urinary catheter were observed in this study. Measurements and main results: A total of 1046 hours of UO were recorded from 23 subjects. Compared with the scale data, the measurements of hourly urine flow measured with the RenalSense system were closer, had a better correlation, and narrower limits of agreement to gravimetrically determined values than the measurements obtained by the nurses. In addition, continuous monitoring of UO provided graphical display of response to repeated diuretic administration. Conclusions: An electronic device for recording UO has been shown to provide more reliable information of UO records and patient fluid status than current practice. Future applications of this device will provide valuable information to help set protocol goals such as decisions for

  18. Detail of photo 7903109 stack of superconducting cables in the modulus measuring device

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    The picture shows an assembly of insulated superconducting cables of the type used in the Po dipole magnet inserted in the elastic modulus measuring device (photos 7903547X and 7903169) in order to measures its mechanical properties under azimuthal compression. See also 7903547X, 7903169, 8307552X.

  19. A simple method for the measurement of reflective foil emissivity

    International Nuclear Information System (INIS)

    Ballico, M. J.; Ham, E. W. M. van der

    2013-01-01

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408

  20. A simple method for the measurement of reflective foil emissivity

    Science.gov (United States)

    Ballico, M. J.; van der Ham, E. W. M.

    2013-09-01

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to "bubble-wrap". Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a "primary method" and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.

  1. Novel simple insulin delivery device reduces barriers to insulin therapy in type 2 diabetes: results from a pilot study.

    Science.gov (United States)

    Hermanns, Norbert; Lilly, Leslie C; Mader, Julia K; Aberer, Felix; Ribitsch, Anja; Kojzar, Harald; Warner, Jay; Pieber, Thomas R

    2015-05-01

    The PaQ® insulin delivery system is a simple-to-use patch-on device that provides preset basal rates and bolus insulin on demand. In addition to feasibility of use, safety, and efficacy (reported elsewhere), this study analyzed the impact of PaQ on patient-reported outcomes, including barriers to insulin treatment, diabetes-related distress, and attitudes toward insulin therapy in patients with type 2 diabetes on a stable multiple daily injection (MDI) regimen. This single-center, open-label, single-arm study comprised three 2-week periods: baseline (MDI), transition from MDI to PaQ, and PaQ treatment. Validated questionnaires were administered during the baseline and PaQ treatment periods: Barriers to Insulin Treatment questionnaire (BIT), Insulin Treatment Appraisal Scale (ITAS), and Problem Areas in Diabetes scale (PAID). Eighteen patients (age 59 ± 5 years, diabetes duration 15 ± 7 years, 21% female, HbA1c 7.7 ± 0.7%) completed the questionnaires. There was a strong, significant effect of PaQ use in mean BIT total scores (difference [D] = -5.4 ± 0.7.7, P = .01, effect size [d] = 0.70). Patients perceived less stigmatization by insulin injection (D = -2.2 ± 6.2, P = .18, d = 0.35), increased positive outcome (D = 1.9 ± 6.6, P = .17, d = 0.29), and less fear of injections (1.3 ± 4.8, P = .55, d = 0.28). Mean change in ITAS scores after PaQ device use showed a nonsignificant improvement of 1.71 ± 5.63 but moderate effect size (d = 0.30, P = .14). No increase in PAID scores was seen. The results and moderate to large effects sizes suggest that PaQ device use has beneficial and clinically relevant effects to overcoming barriers to and negative appraisal of insulin treatment, without increasing other diabetes-related distress. © 2015 Diabetes Technology Society.

  2. Simple and rapid measurement of α-rays on smear samples using air luminescence

    International Nuclear Information System (INIS)

    Takiue, M.

    1980-01-01

    The α-activity collected on smear samples has been measured indirectly using an air luminescence counting method and a liquid scintillation spectrometer. In this method, air luminescence, attributed to the fluorescence emitted by nitrogen molecules excited by α-rays in air, serves to detect α-rays. Thus, sample preparation and α-ray measurement are simple and rapid, and moreover, no radioactive waste solution is produced. Taking into account a low background and a counting efficiency between 10 and 20%, it is estimated that the detectable limit for α-ray measurement is about 1 x 10 -7 μCi/cm 2 for loose contamination. This method is convenient to use in the routine analysis of α-ray-emitting nuclides on smear paper. (author)

  3. Computed tomography measurement of the left atrial appendage for optimal sizing of the Watchman device.

    Science.gov (United States)

    Xu, Bo; Betancor, Jorge; Sato, Kimi; Harb, Serge; Abdur Rehman, Karim; Patel, Kunal; Kumar, Arnav; Cremer, Paul C; Jaber, Wael; Rodriguez, L Leonardo; Schoenhagen, Paul; Wazni, Oussama

    Percutaneous left atrial appendage (LAA) occlusion is an emerging treatment option for patients with non-valvular atrial fibrillation who cannot tolerate oral anticoagulation. The Watchman device (Boston Scientific Corporation, Natick, MA, USA) is deployed at the ostium of the LAA, and an appropriately sized device is critical for successful occlusion. However, standardized imaging protocols for device sizing have not been established. We investigated the clinical utility of a standardized imaging protocol, with pre-procedural multi-detector cardiac computed tomography (MDCT), and intra-procedural transesophageal echocardiography (TEE), for Watchman device sizing. Patients who underwent Watchman device implantation between 2010 and 2016 at our center, and who had pre-procedural MDCT and intra-procedural TEE were included. MDCT measurements (CTmax, CTmin, CTmean), and TEE measurement (TEEmax) of the LAA ostium were determined for each case, and correlated with the final size of the Watchman device implanted. Demographic data and clinical outcomes were collected. The study included 80 patients (mean age: 75 ± 9.6 years; male: 68%; mean CHA2DS2-VASc score: 4.5 ± 1.4). CTmax of the LAA ostium correlated strongly with the final deployed Watchman device size (Spearman's rho: 0.81, p < 0.001), while TEEmax of the LAA ostium showed only moderate correlation with the final deployed Watchman device size (Spearman's rho: 0.61, p < 0.001). Implantation success rate was 100%. At a mean duration of follow-up of 197 days, there were no device-related complications (device embolization, cardiac perforation and pericardial tamponade). At follow-up, the vast majority of patients (76 patients; 95%) had either no or trivial (≤3 mm) residual peri-device leak on TEE. A standardized imaging protocol for assessment of Watchman device implantation incorporating pre-procedural MDCT and intra-procedural TEE, was associated with excellent procedural outcomes at a mean duration

  4. Attenuation length measurements of a liquid scintillator with LabVIEW and reliability evaluation of the device

    International Nuclear Information System (INIS)

    Gao Long; Yu Boxiang; Ding Yayun

    2013-01-01

    An attenuation length measurement device was constructed using an oscilloscope and LabVIEW for signal acquisition and processing. The performance of the device has been tested in a variety of ways. The test results show that the set-up has a good stability and high precision (sigma/mean reached 0.4 percent). Besides, the accuracy of the measurement system will decrease by about 17 percent if a filter is used. The attenuation length of a gadolinium-loaded liquid scintillator (Gd-LS) was measured as 15.10±0.35 m where Gd-LS was heavily used in the Daya Bay Neutrino Experiment. In addition, one method based on the Beer-Lambert law was proposed to investigate the reliability of the measurement device, the R-square reached 0.9995. Moreover, three purification methods for Linear Alkyl Benzene (LAB) production were compared in the experiment. (authors)

  5. Reliability of Sleep Measures from Four Personal Health Monitoring Devices Compared to Research-Based Actigraphy and Polysomnography

    Directory of Open Access Journals (Sweden)

    Janna Mantua

    2016-05-01

    Full Text Available Polysomnography (PSG is the “gold standard” for monitoring sleep. Alternatives to PSG are of interest for clinical, research, and personal use. Wrist-worn actigraph devices have been utilized in research settings for measures of sleep for over two decades. Whether sleep measures from commercially available devices are similarly valid is unknown. We sought to determine the validity of five wearable devices: Basis Health Tracker, Misfit Shine, Fitbit Flex, Withings Pulse O2, and a research-based actigraph, Actiwatch Spectrum. We used Wilcoxon Signed Rank tests to assess differences between devices relative to PSG and correlational analysis to assess the strength of the relationship. Data loss was greatest for Fitbit and Misfit. For all devices, we found no difference and strong correlation of total sleep time with PSG. Sleep efficiency differed from PSG for Withings, Misfit, Fitbit, and Basis, while Actiwatch mean values did not differ from that of PSG. Only mean values of sleep efficiency (time asleep/time in bed from Actiwatch correlated with PSG, yet this correlation was weak. Light sleep time differed from PSG (nREM1 + nREM2 for all devices. Measures of Deep sleep time did not differ from PSG (SWS + REM for Basis. These results reveal the current strengths and limitations in sleep estimates produced by personal health monitoring devices and point to a need for future development.

  6. Electric discharge machining device for laboratories and workshops

    International Nuclear Information System (INIS)

    Lanxner, M.; Berko, A.; Ron, N.

    1976-11-01

    A simple low power electric discharge machining (EDM) device for special uses in laboratories and workshops is presented. The device includes an RC generator, an electromechanical servo 3-axis work-tool alignment system and a closed dielectric fluid circulation loop

  7. α-sealed transfer device and portable plastic film sealers

    International Nuclear Information System (INIS)

    Fu Zhujun; Shan Ruixia

    1990-04-01

    An α transfer device which can be operated remotely is presented. The device is able to perform sealed transfer of radioactive articles from a hot cell or shielded glove box to the outside and non-radioactive articles from the outside to a hot cell or shielded glove box by using bag sealing technology. The structure of the transfer device is simple. Its operation is safe and reliable. The sealing performance of the device is very good (for alpha). The use of this transfer device will greatly reduce α contamination of the building and creates a favourable condition for operating radioactive materials in an undivided area. The portable heat sealing device is also a necessary tool in bag sealing technology and α-sealed transfer. Two types of portable plastic film sealers have been developed. Their structure is simple. The operation of the portable plastic film sealers is easy. Their performance is also excellent. Both the α-sealed transfer device and portable plastic film sealers are very useful to the reprocessing plant of nuclear fuel

  8. Alpha Beam Energy Determination Using a Range Measuring Device for Radioisotope Production

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Jun Yong; Kim, Byeon Gil; Hong, Seung Pyo; Kim, Ran Young; Chun, Kwon Soo [Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of)

    2016-05-15

    The threshold energy of the {sup 209}Bi(α,3n){sup 210} At reaction is at about 30MeV. Our laboratory suggested an energy measurement method to confirm the proton-beam's energy by using a range measurement device. The experiment was performed energy measurement of alpha beam. The alpha beam of energy 29 MeV has been extracted from the cyclotron for the production of {sup 211}At. This device was composed of four parts: an absorber, a drive shaft, and a servo motor and a Faraday cup. The drive shaft was mounted on the absorber and connects with the axis of the servo motor and rotates linearly and circularly by this servo motor. A Faraday cup is for measuring the beam flux. As this drive shaft rotates, the thickness of the absorber varies depending on the rotation angle of the absorber. The energy of the alpha particle accelerated and extracted from MC-50 cyclotron was calculated with the measurement of the particle range in Al foil and using ASTAR, SRIM, MCNPX software. There were a little discrepancy between the expected energy and the calculated energy within the 0.5MeV error range. We have a plan to make an experiment with various alpha particle energies and another methodology, for example, the cross section measurement of the nuclear reaction.

  9. Embedded RFID Recorder in short-range wireless devices

    DEFF Research Database (Denmark)

    2010-01-01

    range communication devices. The problem is solved in that the portable communications device comprises a wireless communications interface for communicating with another device, a memory and an RFID-recorder for receiving an RFID-signal transmitted from an RFID-interrogator, wherein the device...... is adapted for storing individual received RFID-signals in the memory. An advantage of the invention is that it provides a relatively simple scheme for extracting information from a current environment of a portable communications device. The invention may e.g. be used for adapting listening devices, e...

  10. Light-induced magnetoresistance in solution-processed planar hybrid devices measured under ambient conditions.

    Science.gov (United States)

    Banerjee, Sreetama; Bülz, Daniel; Reuter, Danny; Hiller, Karla; Zahn, Dietrich R T; Salvan, Georgeta

    2017-01-01

    We report light-induced negative organic magnetoresistance (OMAR) measured in ambient atmosphere in solution-processed 6,13-bis(triisopropylsilylethynyl)pentacene (TIPS-pentacene) planar hybrid devices with two different device architectures. Hybrid electronic devices with trench-isolated electrodes (HED-TIE) having a channel length of ca. 100 nm fabricated in this work and, for comparison, commercially available pre-structured organic field-effect transistor (OFET) substrates with a channel length of 20 µm were used. The magnitude of the photocurrent as well as the magnetoresistance was found to be higher for the HED-TIE devices because of the much smaller channel length of these devices compared to the OFETs. We attribute the observed light-induced negative magnetoresistance in TIPS-pentacene to the presence of electron-hole pairs under illumination as the magnetoresistive effect scales with the photocurrent. The magnetoresistance effect was found to diminish over time under ambient conditions compared to a freshly prepared sample. We propose that the much faster degradation of the magnetoresistance effect as compared to the photocurrent was due to the incorporation of water molecules in the TIPS-pentacene film.

  11. Off-axis electron holography for the measurement of active dopants in silicon semiconductor devices

    International Nuclear Information System (INIS)

    Cooper, David

    2016-01-01

    There is a need in the semiconductor industry for a dopant profiling technique with nm-scale resolution. Here we demonstrate that off-axis electron holography can be used to provide maps of the electrostatic potential in semiconductor devices with nm-scale resolution. In this paper we will discuss issues regarding the spatial resolution and precision of the technique. Then we will discuss problems with specimen preparation and how this affects the accuracy of the measurements of the potentials. Finally we show results from experimental off-axis electron holography applied to nMOS and pMOS CMOS devices grown on bulk silicon and silicon- on-insulator type devices and present solutions to common problems that are encountered when examining these types of devices. (paper)

  12. Device for measuring mass of air. Einrichtung zur Luftmassenmessung

    Energy Technology Data Exchange (ETDEWEB)

    Sass, W

    1989-09-28

    In a device for measuring the mass of air, particularly for vehicles with internal combustion engines, with a measurement bridge, in one branch of which an air flow resistance, particularly a hot film sensor, which has air flowing round it, is connected in series with a measuring resistance and in another branch of which a compensation resistance measuring the air temperature is connected in series with a fixed resistor, where the bridge differential voltage is measured in the zero branch of the measuring bridge and the resulting signal is used to control a transistor valve situated in the bridge supply path of a bridge supply source with an emitter connected to the bridge via the transistor base for bridge compensation and where the voltage at the measurement resistance after bridge compensation is evaluated as a measure of the air flow, the invention proposes that the transistor valve should be made as an npn transistor blocking for negative voltage peaks in the bridge supply path. This ensures that for netgative voltage peaks in the supply line, the transistor valve closes temporarily and overheating of the measurement bridge is prevented. Such overheating would lead to measurement of too great air mass flow and therefore to a dangerously too rich fuel/air mixture, for example (instead the negative voltage peaks give a safe temporary lean mixture).

  13. The measurement of potential distribution of plasma in MM-4 fusion device

    International Nuclear Information System (INIS)

    Tian Zhongyu; Ming Linzhou; Feng Xiaozhen; Feng Chuntang; Yi Youjun; Wang Jihai; Liu Yihua

    1988-11-01

    Some experimental results of the potential distribution in MM-4 fusion device are presented by measuring the floating potential of probe. The results showed that the distribution of axial potential is asymmetrical, but the radial potential is symmetrical. There are double ion potential wells in the plasma. The depth of the deepest potential well become deeper is the strength of the magnetic field and injection current are increasing. The location of the deepest well is moved towards the device center along with the increasing of injection energy. This is different from others results. The mechanism of causing this distribution in also discussed

  14. Device for simultaneous measurements of the optical and dielectric properties of hydrogels

    International Nuclear Information System (INIS)

    Gómez-Galván, F; Lara-Ceniceros, T; Mercado-Uribe, H

    2012-01-01

    We have designed an experimental device to simultaneously measure the light transmittance and dielectric properties of thermo-sensitive hydrogels. We have used this device to study poly(N-isopropylacrylamide) samples in order to understand the mechanism of water deliverance during the phase transition such hydrogels normally exhibit. We found that the phase transition can be observed dielectrically at low frequencies, when the isothermals obtained during the heating of the samples separate into two groups. The phenomenon occurs due to the increase of ions caused by the dissociation of water molecules released by the polymer, and corresponds to the drop of the optical transmittance

  15. In vivo determination of tooth mobility after fixed orthodontic appliance therapy with a novel intraoral measurement device.

    Science.gov (United States)

    Konermann, Anna; Al-Malat, R; Skupin, J; Keilig, L; Dirk, C; Karanis, R; Bourauel, C; Jäger, A

    2017-05-01

    Valid measurement systems recording tooth mobility upon displacement within the subtle range of physiological strains are missing. Here, we introduce a novel in vivo measurement device and demonstrate a first clinical application by monitoring tooth mobility changes during retention after fixed multibracket appliance therapy. Tooth mobility was measured in vivo on 21 patients (11 female, 10 male; mean age 16.1 ± 3.1 years) by displacing the upper first incisor 0.2 mm lingually for 0.2, 0.5, 1, 2, 5, and 10 s with the novel intraoral device. Measurements were recorded directly after, as much as 2, 7, and 14 days and up to 6 months after appliance debonding. Device performance was precise and valid in clinical use. Data revealed significant interindividual varying tooth mobility, which was very high during the first 2 days after appliance removal. After 1 week, mobility values decreased, but were generally higher upon short loadings compared to long ones. After 3 months, tooth mobility was significantly lower than directly after debonding. Interestingly, males exhibited significantly less mobility than females. Our work is the first using an in vivo measurement device capable of performing and recording tooth displacements within this delicate range and in such precision. Furthermore, our findings elucidate tooth mobility changes after multibracket treatment, giving important information for retention periods. Establishment of this novel measurement device in clinical use is an important improvement when approaching the complexity of tooth mobility in vivo regarding different issues like orthodontics, periodontal disease, or bruxism.

  16. Reactor power region measuring device

    International Nuclear Information System (INIS)

    Kashiwa, Takao.

    1996-01-01

    The device of the present invention can rapidly detect abnormality of a local power region monitor (LPRM) even at a low power region caused such as upon start-up of a BWR type reactor. Namely, the present invention comprises (1) an LPRM detector for measuring neutron fluxes in the reactor, (2) a gamma thermo detector for calibrating the sensitivity of the LPRM detector, (3) a comparison circuit for comparing the detected values of the detectors (1) and (2), and (4) an alarm circuit for outputting an alarm when the comparative difference of the output of the circuit (3) exceeds a predetermined value. Signals of an alarm for a lower limit of the LPRM detector have been issued continuously upon start-up and shut down of the reactor since neutron fluxes in the reactor are reduced. However, the gamma thermo detector is always secured in the inside of the reactor different from a travelling-type incore probe monitor (TIP) disposed so far for the same purpose. Accordingly, the alarm generated upon usual start-up can be eliminated by comparing the detected values of the detector (2) and abnormality of the detector (1) can be rapidly detected by judging the abnormality of the comparative difference. (I.S.)

  17. Gauging device

    International Nuclear Information System (INIS)

    Qurnell, F.D.; Patterson, C.B.

    1979-01-01

    A gauge supporting device for measuring say a square tube comprises a pair of rods or guides in tension between a pair of end members, the end members being spaced apart by a compression member or members. The tensioned guides provide planes of reference for measuring devices moved therealong on a carriage. The device is especially useful for making on site dimensional measurements of components, such as irradiated and therefore radioactive components, that cannot readily be transported to an inspection laboratory. (UK)

  18. Development of the ''measurement and sorting'' device for bituminized waste drums at Cogema Marcoule

    International Nuclear Information System (INIS)

    Chabalier, B.; Artaud, J.L.; Perot, B.; Passard, C.; Romeyer Dherbey, J.; Raoux, A.; Misraki, J.

    2000-01-01

    This programme is included in the scope of a specific task to retrieve bituminized waste drums stored on the Marcoule site. The objective is to define a non-destructive nuclear measurement facility that makes it possible to: - sort the packages stored on the site according to the radiological acceptance criteria for the waste packages in the surface storage facility, - establish the β and α activities of the packages to be stored in the surface storage facility, - estimate the activity of the packages that will be stored in the ''Entreposage Intermediaire Polyvalent'' (multiple purpose intermediate storage) built on the Marcoule site. A measurement facility, with measurement times compatible with the industrial flow of retrieval of the waste drums was studied, developed and will be validated. It features gamma spectrometry measurements and neutron measurement devices, associated to an imaging device by photonic transmission and an expert system. Studies associated to the definition of this facility mainly concern: - the imaging station: it enables to know up to what height the packages are filled, the actual density of the matrix, and to detect lacks of homogeneity. These data are required for a correct analysis of the neutron or gamma measurements and to minimise uncertainties, - the interpretation of active neutron measurement signals: a simultaneous detection of the prompt and delayed neutrons makes it possible to differentiate the masses of U-235 and of Pu-239 present in the packages, - the reduction of the detection limits: to that end, an ''asti-Compton'' detector was defined providing a gain on the detection limits at low energies according to the type of GeHP semi-conductor detector. - the expert system which performs the interpretation and coupling of measured data with data coming from the waste production files in order to determine the activity of the β γ, pure β and α radionuclides at 300 years. The validation program that will be conducted on a

  19. Control and Data Analysis for Emittance Measuring Devices

    CERN Document Server

    Hoffmann, T

    2001-01-01

    Due to the wide range of heavy ion beam intensities and energies in the GSI linac and the associated transfer channel to the synchrotron, several different types of emittance measurement systems have been established. Many common devices such as slit/grid or dipole-sweep systems are integrated into the GSI control system. Other systems like the single shot pepper pot method using CCD-cameras or stand-alone slit/grid set-ups are connected to personal computers. An overview is given about the various systems and their software integration. Main interest is directed on the software development for emittance front-end control and data analysis such as evaluation algorithms or graphical presentation of the results. In addition, special features for improved usability of the software such as data export, project databases and automatic report generation will be presented. An outlook on a unified evaluation procedure for all different types of emittance measurement is given.

  20. Radiological response of ceramic and polymeric devices for breast brachytherapy

    International Nuclear Information System (INIS)

    Batista Nogueira, Luciana; Passos Ribeiro de Campos, Tarcisio

    2012-01-01

    In the present study, the radiological visibility of ceramic and polymeric devices implanted in breast phantom was investigated for future applications in brachytherapy. The main goal was to determine the radiological viability of ceramic and polymeric devices in vitro by performing simple radiological diagnostic methods such as conventional X-ray analysis and mammography due to its easy access to the population. The radiological response of ceramic and polymeric devices implanted in breast phantom was determined using conventional X-ray, mammography and CT analysis. - Highlights: ► Radiological visibility of ceramic and polymeric devices implanted in breast phantom. ► The barium incorporation in the seed improves the radiological contrast. ► Radiological monitoring shows the position, orientation and degradation of devices. ► Simple radiological methods such as X-ray and mammography were used for radiological monitoring.

  1. Design of portable electrocardiogram device using DSO138

    Science.gov (United States)

    Abuzairi, Tomy; Matondang, Josef Stevanus; Purnamaningsih, Retno Wigajatri; Basari, Ratnasari, Anita

    2018-02-01

    Cardiovascular disease has been one of the leading causes of sudden cardiac deaths in many countries, covering Indonesia. Electrocardiogram (ECG) is a medical test to detect cardiac abnormalities by measuring the electrical activity generated by the heart, as the heart contracts. By using ECG, we can observe anomaly at the time of heart abnormalities. In this paper, design of portable ECG device is presented. The portable ECG device was designed to easily use in the village clinic or houses, due to the small size device and other benefits. The device was designed by using four units: (1) ECG electrode; (2) ECG analog front-end; (3) DSO138; and (4) battery. To create a simple electrode system in the portable ECG, 1-lead ECG with two electrodes were applied. The analog front-end circuitry consists of three integrated circuits, an instrumentation amplifier AD820AN, a low noise operational amplifier OPA134, and a low offset operational amplifier TL082. Digital ECG data were transformed to graphical data on DSO138. The results show that the portable ECG is successfully read the signal from 1-lead ECG system.

  2. Simple gun for vapor deposition of organic thin films

    International Nuclear Information System (INIS)

    Sato, N.; Seki, K.; Inokuchi, H.

    1987-01-01

    A simple evaporation gun for preparing organic thin films was fabricated using commercially available parts of an electron gun for a TV Braun tube. The device permits sample heating to be easily controlled because of the small heat capacity

  3. New performance in harmonic analysis device generation used for magnetic fields measurements

    Energy Technology Data Exchange (ETDEWEB)

    Evesque, C.; Tkatchenko, M.

    1996-12-31

    In particle accelerator, correcting high multipole components of magnets are of high importance for quality magnet: to get a pure quadrupole to within 10{sup -4}, we have to know the field quality to 10{sup -5} through the 30. order. Our laboratory needed such a very sharp device to find small harmonic components of magnetic field. For harmonic analysis of magnetic field, we adopted the standard method, i.e. a rotating coil connected to a flux integrator. Nowadays, coils measuring azimuthal component of magnetic field are used. In order to obtain correct and accurate measurements, we were guided by two imperatives: first, optimisation of construction constraints and second, comparison of azimuthal and radial component measurements. With this background, this article describes both new technological solutions adopted and new performance obtained. We also discuss the most suitable geometric structure for the coils. We obtained a noiseless signal, a repeatability of 10{sup -5} and a sensitivity up to 10{sup -8} Weber for both types of coils. Our device is able to find and measure main component, normal and skew multipole components up to the 32. order, when simulating local defects. The magnetic axis is located within 5 {mu}m. The central gradient is also measured and magnetic length deduced. Complementary functions of two types of coils were noticed in detecting local defects of magnetic structure. (authors).

  4. New performance in harmonic analysis device generation used for magnetic fields measurements

    International Nuclear Information System (INIS)

    Evesque, C.; Tkatchenko, M.

    1996-01-01

    In particle accelerator, correcting high multipole components of magnets are of high importance for quality magnet: to get a pure quadrupole to within 10 -4 , we have to know the field quality to 10 -5 through the 30. order. Our laboratory needed such a very sharp device to find small harmonic components of magnetic field. For harmonic analysis of magnetic field, we adopted the standard method, i.e. a rotating coil connected to a flux integrator. Nowadays, coils measuring azimuthal component of magnetic field are used. In order to obtain correct and accurate measurements, we were guided by two imperatives: first, optimisation of construction constraints and second, comparison of azimuthal and radial component measurements. With this background, this article describes both new technological solutions adopted and new performance obtained. We also discuss the most suitable geometric structure for the coils. We obtained a noiseless signal, a repeatability of 10 -5 and a sensitivity up to 10 -8 Weber for both types of coils. Our device is able to find and measure main component, normal and skew multipole components up to the 32. order, when simulating local defects. The magnetic axis is located within 5 μm. The central gradient is also measured and magnetic length deduced. Complementary functions of two types of coils were noticed in detecting local defects of magnetic structure. (authors)

  5. OVERVIEW OF NEUTRON MEASUREMENTS IN JET FUSION DEVICE.

    Science.gov (United States)

    Batistoni, P; Villari, R; Obryk, B; Packer, L W; Stamatelatos, I E; Popovichev, S; Colangeli, A; Colling, B; Fonnesu, N; Loreti, S; Klix, A; Klosowski, M; Malik, K; Naish, J; Pillon, M; Vasilopoulou, T; De Felice, P; Pimpinella, M; Quintieri, L

    2017-10-05

    The design and operation of ITER experimental fusion reactor requires the development of neutron measurement techniques and numerical tools to derive the fusion power and the radiation field in the device and in the surrounding areas. Nuclear analyses provide essential input to the conceptual design, optimisation, engineering and safety case in ITER and power plant studies. The required radiation transport calculations are extremely challenging because of the large physical extent of the reactor plant, the complexity of the geometry, and the combination of deep penetration and streaming paths. This article reports the experimental activities which are carried-out at JET to validate the neutronics measurements methods and numerical tools used in ITER and power plant design. A new deuterium-tritium campaign is proposed in 2019 at JET: the unique 14 MeV neutron yields produced will be exploited as much as possible to validate measurement techniques, codes, procedures and data currently used in ITER design thus reducing the related uncertainties and the associated risks in the machine operation. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  6. Concordance of Adherence Measurement Using Self-Reported Adherence Questionnaires and Medication Monitoring Devices: An Updated Review.

    Science.gov (United States)

    Monnette, Alisha; Zhang, Yichen; Shao, Hui; Shi, Lizheng

    2018-01-01

    As medication adherence continues to be a prevalent issue in today's society, the methods used to monitor medication-taking behaviors are constantly being re-evaluated and compared in search of the 'gold standard' measure. Our review aimed to assess the current literature surrounding the correlation between self-reported questionnaires (SRQs) and electronic monitoring devices to determine if these measures produce similar results. We performed a literature search from 2009 to 2017 using PubMed, PubMed In-Process and Non-Indexed, EMBASE, Ovid MEDLINE, and Ovid MEDLINE In-Process. A keyword search using the terms 'patient compliance', 'treatment compliance', 'medication adherence', 'drug monitoring', 'drug therapy', 'electronic', 'digital', 'computer', 'monitor', 'monitoring', 'drug', 'pharmaceutical preparations', 'compliance', and 'medications' was done to capture all articles. We included articles measuring adherence using both monitoring devices and SRQs. Thirty-five articles were included in this review. The average difference in measured adherence rates between the two measures was 9.2% (range -66.3 to 61.5). A majority (62.7%) of articles reported moderate (n = 12; 27.9%), high (n = 5, 11.6%), or significant (n = 10, 23.3%) correlations between SRQs and monitoring devices. Results from our review are consistent with previous studies, as we found that many of our studies produced moderate to high correlation between both SRQs and monitoring devices [Farmer, Clin Ther 21(6):1074-90 (1999), IMS Institute for Healthcare Informatics. Avoidable costs in US health care (2012), Patel et al., Respirology 18(3):546-52 (2013), Siracusa et al., J Cyst Fibros 14(5):621-6 (2015), Smith et al., Int J Cardiol 145(1):122-3 (2010)]. Our findings demonstrate that self-reported adherence produces comparable results to electronic monitoring devices. As there is not yet a 'gold standard' measure for monitoring patient adherence, SRQs and Medication Event Monitoring Systems

  7. Liquid temperature measuring method and device therefor

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Fumi; Karasawa, Hirokazu

    1995-06-02

    In the present invention, temperature of liquid metal in coolants in an FBR type reactor can accurately be measured at rapid response time. Namely, ultrasonic waves are emitted from an ultrasonic wave sensor disposed in the air to a guide wave tube. Ultrasonic waves are reflected at reflection plates disposed at front and back or upper and lower portions of a small hole disposed to the wave guide tube. The reflected waves are received by the sensor described above. The difference of the reaching time of the reflected waves from the reflecting plates disposed at the front and the back or the upper and lower portions is measured. The speed of sounds in this case is determined based on the size of the small hole and the distance of the upper and the lower reflection plates. The speed of sounds is determined by the formula below: V(m/s) = 2500 - 0.52 T, where T: temperature. The temperature of the liquid can easily be calculated based on the formula. Accordingly, since the speed of the ultrasonic waves from their emission to the reception is msec order, and the processing of the signals are simple, the temperature can be measured at a response time of several msecs. In addition, since the ultrasonic wave sensor is disposed at the outside of the reactor, no special countermeasure for environmental circumstances is necessary, to improve maintenance ability. (I.S.).

  8. Software to manage transformers using intelligent electronic device

    Directory of Open Access Journals (Sweden)

    Marcio Zamboti Fortes

    2016-01-01

    Full Text Available Power companies usually answer the increase in power demand by building new generation facilities. Nevertheless, an efficient use of energy could reduce and delay the costs of investment in new power plants. This paper shows a software system to manage transformers and evaluate losses when they work with zero loads. This system contributes to reduce the waste of energy with some simple actions such as shutting off an unused transformer or reconnecting disabled equipment based on the customer’s demand. It uses real time measurements collected from Intelligent Electronic Devices as a base for software decisions. It also measures and reports the total power saving.

  9. A simple 5-DoF MR-compatible motion signal measurement system.

    Science.gov (United States)

    Chung, Soon-Cheol; Kim, Hyung-Sik; Yang, Jae-Woong; Lee, Su-Jeong; Choi, Mi-Hyun; Kim, Ji-Hye; Yeon, Hong-Won; Park, Jang-Yeon; Yi, Jeong-Han; Tack, Gye-Rae

    2011-09-01

    The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made of copper and aluminum. The motion signal was modulated to an optic signal using pulse width modulation, and the modulated optic signal was transmitted outside the MR shield room using a high-intensity light-emitting diode and an optic cable. The motion signal was recorded on a PC by demodulating the transmitted optic signal into an electric signal. Various kinematic variables, such as angle, acceleration, velocity, and jerk, can be measured or calculated by using the motion measurement system developed here. This system also enables motion tracking by extracting the position information from the motion signals. It was verified that MR images and motion signals could reliably be measured simultaneously.

  10. Low-temperature mobility measurements on CMOS devices

    International Nuclear Information System (INIS)

    Hairpetian, A.; Gitlin, D.; Viswanathan, C.R.

    1989-01-01

    The surface channel mobility of carriers in eta- and rho-MOS transistors fabricated in a CMOS process was accurately determined at low temperatures down to 5 Κ. The mobility was obtained by an accurate measurement of the inversion charge density using a split C-V technique and the conductance at low drain voltages. The split C-V technique was validated at all temperatures using a one-dimensional Poisson solver (MOSCAP), which was modified for low-temperature application. The mobility dependence on the perpendicular electric field for different substrate bias values appears to have different temperature dependence for eta- and rho-channel devices. The electron mobility increases with a decrease in temperature at all gate voltages. On the other hand, the hole mobility exhibits a different temperature behavior depending upon whether the gate voltage corresponds to strong inversion or is near threshold

  11. Penile measurements in Tanzanian males: guiding circumcision device design and supply forecasting.

    Science.gov (United States)

    Chrouser, Kristin; Bazant, Eva; Jin, Linda; Kileo, Baldwin; Plotkin, Marya; Adamu, Tigistu; Curran, Kelly; Koshuma, Sifuni

    2013-08-01

    Voluntary medical male circumcision decreases the risk in males of HIV infection through heterosexual intercourse by about 60% in clinical trials and 73% at post-trial followup. In 2007 WHO and the Joint United Nations Programme on HIV/AIDS (UNAIDS) recommended that countries with a low circumcision rate and high HIV prevalence expand voluntary medical male circumcision programs as part of a national HIV prevention strategy. Devices for adult/adolescent male circumcision could accelerate the pace of scaling up voluntary medical male circumcision. Detailed penile measurements of African males are required for device development and supply size forecasting. Consenting males undergoing voluntary medical male circumcision at 3 health facilities in the Iringa region, Tanzania, underwent measurement of the penile glans, shaft and foreskin. Age, Tanner stage, height and weight were recorded. Measurements were analyzed by age categories. Correlations of penile parameters with height, weight and body mass index were calculated. In 253 Tanzanian males 10 to 47 years old mean ± SD penile length in adults was 11.5 ± 1.6 cm, mean shaft circumference was 8.7 ± 0.9 cm and mean glans circumference was 8.8 ± 0.9 cm. As expected, given the variability of puberty, measurements in younger males varied significantly. Glans circumference highly correlated with height (r = 0.80) and weight (r = 0.81, each p <0.001). Stretched foreskin diameter moderately correlated with height (r = 0.68) and weight (r = 0.71, each p <0.001). Our descriptive study provides penile measurements of males who sought voluntary medical male circumcision services in Iringa, Tanzania. To our knowledge this is the first study in a sub-Saharan African population that provides sufficiently detailed glans and foreskin dimensions to inform voluntary medical male circumcision device development and size forecasting. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier

  12. Device for measuring hole elongation in a bolted joint

    Science.gov (United States)

    Wichorek, Gregory R. (Inventor)

    1987-01-01

    A device to determine the operable failure mode of mechanically fastened lightweight composite joints by measuring the hole elongation of a bolted joint is disclosed. The double-lap joint test apparatus comprises a stud, a test specimen having a hole, two load transfer plates, and linear displacement measuring instruments. The test specimen is sandwiched between the two load transfer plates and clamped together with the stud. Spacer washers are placed between the test specimen and each load transfer plate to provide a known, controllable area for the determination of clamping forces around the hole of the specimen attributable to bolt torque. The spacer washers also provide a gap for the mounting of reference angles on each side of the test specimen. Under tensile loading, elongation of the hole of the test specimen causes the stud to move away from the reference angles. This displacement is measured by the voltage output of two linear displacement measuring instruments that are attached to the stud and remain in contact with the reference angles throughout the tensile loading. The present invention obviates previous problems in obtaining specimen deformation measurements by monitoring the reference angles to the test specimen and the linear displacement measuring instruments to the stud.

  13. Light-induced magnetoresistance in solution-processed planar hybrid devices measured under ambient conditions

    Directory of Open Access Journals (Sweden)

    Sreetama Banerjee

    2017-07-01

    Full Text Available We report light-induced negative organic magnetoresistance (OMAR measured in ambient atmosphere in solution-processed 6,13-bis(triisopropylsilylethynylpentacene (TIPS-pentacene planar hybrid devices with two different device architectures. Hybrid electronic devices with trench-isolated electrodes (HED-TIE having a channel length of ca. 100 nm fabricated in this work and, for comparison, commercially available pre-structured organic field-effect transistor (OFET substrates with a channel length of 20 µm were used. The magnitude of the photocurrent as well as the magnetoresistance was found to be higher for the HED-TIE devices because of the much smaller channel length of these devices compared to the OFETs. We attribute the observed light-induced negative magnetoresistance in TIPS-pentacene to the presence of electron–hole pairs under illumination as the magnetoresistive effect scales with the photocurrent. The magnetoresistance effect was found to diminish over time under ambient conditions compared to a freshly prepared sample. We propose that the much faster degradation of the magnetoresistance effect as compared to the photocurrent was due to the incorporation of water molecules in the TIPS-pentacene film.

  14. Isolation Mounting for Charge-Coupled Devices

    Science.gov (United States)

    Goss, W. C.; Salomon, P. M.

    1985-01-01

    CCD's suspended by wires under tension. Remote thermoelectric cooling of charge coupled device allows vibration isolating mounting of CCD assembly alone, without having to suspend entire mass and bulk of thermoelectric module. Mounting hardware simple and light. Developed for charge-coupled devices (CCD's) in infrared telescope support adaptable to sensors in variety of environments, e.g., sensors in nuclear reactors, engine exhausts and plasma chambers.

  15. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    Science.gov (United States)

    Sutanto, E.; Chandra, F.; Dinata, R.

    2017-05-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA.

  16. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    International Nuclear Information System (INIS)

    Sutanto, E; Chandra, F; Dinata, R

    2017-01-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA. (paper)

  17. Device for measuring the angle of repose of materials or goniometer

    Energy Technology Data Exchange (ETDEWEB)

    Depoitier, J [Institut National des Radioelements, Brussels (Belgium); Parisis, J; Rossion, R [Cimenteries CBR Cementbedrijven, Brussels (Belgium)

    1980-01-01

    The slope measuring facility consists essentially of a gamma source (Cobalt 60) positioned in front of the main position of the batter and of two scintillators (NaI crystals) opposite the source. The different absorption values piched up by the two detectors allow to determine the angle of repose of the batter. The device was especially studied for cement kilns.

  18. The device for measuring amplitude spectra of ionizing irradiation

    International Nuclear Information System (INIS)

    Polyak, Yu.V.; Nebesnyj, A.F.

    1996-01-01

    The front-end electronic device for measuring of amplitude spectra of ionizing radiation have been made. The device have connection interface with the ionizing radiation detector, the pulse former, adapter, memory, electron ray tube with diode, supply unit and the regime setting unit of the work of electron ray tube. There are linear transmission scheme, level discriminator, pulse series - channel code converter, dividing capacitor in the device. Dynode of electron ray tube has been made in the form of rack or pads installed in the line parallel to axis of vertical scanning and electrically joined with each other. The distance between next tooth of rack or pads is Δy≥0,5 d, where d - diameter of focused electron beam of electron ray tube. The output of pulse former is joined with level discriminator and the first entrance of linear transmission scheme. The output of linear transmission scheme is joined with the entrance of pulse delay scheme, and the second entrance is joined with the first output of level discriminator. The output of pulse delay scheme is joined with Y-deflecting plate of electron ray tube. The first and the second entrance of pulse series - channel code converter are joined correspondingly with the output of adapter and the second output of level discriminator, and its output - with the entrance of memory unit. The first pin of loading resistor is joined through dividing capacitor with the entrance of adapter, its second pin - with the anode output nearest to dynode of electron ray tube. (E.V.Kh.)

  19. A Simple Experiment to Determine the Characteristics of an NTC Thermistor for Low-Temperature Measurement Applications

    Science.gov (United States)

    Mawire, A.

    2012-01-01

    A simple low-cost experiment for undergraduate students to determine the characteristics of a negative temperature coefficient of resistance thermistor is presented. The experiment measures the resistance-temperature and voltage-temperature characteristics of the thermistor. Results of the resistance-temperature experiment are used to determine…

  20. Development of Measurement Device of Working Radius of Crane Based on Single CCD Camera and Laser Range Finder

    Science.gov (United States)

    Nara, Shunsuke; Takahashi, Satoru

    In this paper, what we want to do is to develop an observation device to measure the working radius of a crane truck. The device has a single CCD camera, a laser range finder and two AC servo motors. First, in order to measure the working radius, we need to consider algorithm of a crane hook recognition. Then, we attach the cross mark on the crane hook. Namely, instead of the crane hook, we try to recognize the cross mark. Further, for the observation device, we construct PI control system with an extended Kalman filter to track the moving cross mark. Through experiments, we show the usefulness of our device including new control system of mark tracking.

  1. 1800 mechanical movements, devices and appliances

    CERN Document Server

    Hiscox, Gardner D

    2007-01-01

    A fascinating compendium of early-20th-century mechanical devices, this expansive work ranges from basic levers to complex machinery. More than 1,800 engravings include simple illustrations and detailed cross-sections.

  2. Tank vent processing system having a corrosion preventive device

    International Nuclear Information System (INIS)

    Ouchi, Shoichi; Sato, Hirofumi

    1987-01-01

    Purpose: To prevent corrosion of a tank vent processing device by injecting an oxygen gas. Constitution: Oxygen gas and phosphorous at high temperature are poured into a tank vent processing device and amorphous oxide layers optimum to the prevention of external corrosion are formed to the inner surface of the device. Since the corrosion preventive device using the oxygen gas injection can be constituted as a relatively simple device, it is more economical than constituting a relatively large tank vent processing device with corrosion resistant stainless steels. (Kamimura, M.)

  3. SU-F-T-282: Quality Assurance for IMRT/VMAT QA Devices: Issues Affecting the Timing for ArcCHECK Recalibration

    Energy Technology Data Exchange (ETDEWEB)

    Steers, J [Cedars Sinai Medical Center, Los Angeles, CA (United States); University of California-Los Angeles, Los Angeles, CA (United States); Fraass, B [Cedars Sinai Medical Center, Los Angeles, CA (United States)

    2016-06-15

    Purpose: To discuss several factors surrounding the decision on when to recalibrate the ArcCHECK device as well as present a simple and efficient monthly check to evaluate ArcCHECK calibrations. Methods: ArcCheck (Sun Nuclear) calibrations were evaluated monthly by measuring a 25×25cm{sup 2} field with 100 MU. Since ArcCHECK measurements are run on an almost nightly basis, such additional square field measurements are obtained with minimal additional effort. An in-house MATLAB script compares two radial (y-direction) profiles from the top/center of the new measurement relative to a baseline measurement acquired at the last device calibration. The program automatically generates PDF profile and percent difference comparisons for inspection. Recalibration is based on inspection of measurement profile shapes and percent differences from the baseline measurement. Results: The method presented here shows the utility of a simple monthly check for evaluating ArcCHECK calibrations, and in addition shows the importance of recalibrating after Linac beam steering. Our device required recalibration approximately every 8–10 months. However, for ease of scheduling, we propose a bi-annual recalibration interval. Clinics with a lighter/heavier IMRT/VMAT QA case load may require different recalibration intervals, which are easily determined using the single-field method presented. Analysis of additional square fields is also easily incorporated, if desired. We further illustrate the importance of array recalibration given that diode irradiation is not uniform over the entire device, with central diodes receiving more than 900 Gy over the course of 10 months and peripheral diodes receiving as little as 50 Gy (in our experience). Finally, we show that timely device recalibration decreases spread in clinical IMRT/VMAT QA gamma passing rates. Conclusion: Quality assurance for ArcCHECK array calibrations is important to ensure quality IMRT/VMAT QA comparisons. For many clinics

  4. A Novel Electronic Device for Measuring Urine Flow Rate: A Clinical Investigation

    OpenAIRE

    Aliza Goldman; Hagar Azran; Tal Stern; Mor Grinstein; Dafna Wilner

    2017-01-01

    Objective: Currently, most vital signs in the intensive care unit (ICU) are electronically monitored. However, clinical practice for urine output (UO) measurement, an important vital sign, usually requires manual recording of data that is subject to human errors. In this study, we assessed the ability of a novel electronic UO monitoring device to measure real-time hourly UO versus current clinical practice. Design: Patients were connected to the RenalSense Clarity RMS Sensor Kit with a sensor...

  5. A simple headspace equilibration method for measuring dissolved methane

    Science.gov (United States)

    Magen, C; Lapham, L.L.; Pohlman, John W.; Marshall, Kristin N.; Bosman, S.; Casso, Michael; Chanton, J.P.

    2014-01-01

    Dissolved methane concentrations in the ocean are close to equilibrium with the atmosphere. Because methane is only sparingly soluble in seawater, measuring it without contamination is challenging for samples collected and processed in the presence of air. Several methods for analyzing dissolved methane are described in the literature, yet none has conducted a thorough assessment of the method yield, contamination issues during collection, transport and storage, and the effect of temperature changes and preservative. Previous extraction methods transfer methane from water to gas by either a "sparge and trap" or a "headspace equilibration" technique. The gas is then analyzed for methane by gas chromatography. Here, we revisit the headspace equilibration technique and describe a simple, inexpensive, and reliable method to measure methane in fresh and seawater, regardless of concentration. Within the range of concentrations typically found in surface seawaters (2-1000 nmol L-1), the yield of the method nears 100% of what is expected from solubility calculation following the addition of known amount of methane. In addition to being sensitive (detection limit of 0.1 ppmv, or 0.74 nmol L-1), this method requires less than 10 min per sample, and does not use highly toxic chemicals. It can be conducted with minimum materials and does not require the use of a gas chromatograph at the collection site. It can therefore be used in various remote working environments and conditions.

  6. Development and validation of the downhole freestanding shear device (DFSD) for measuring the dynamic properties of clay.

    Science.gov (United States)

    2008-12-01

    The Downhole Freestanding Shear Device (DFSD) is an innovative tool developed for in situ measurement of dynamic : properties (modulus and damping) of clay soils over a broad range of strains. The device essentially performs : laboratory-quality tors...

  7. Properties of CMOS devices and circuits fabricated on high-resistivity, detector-grade silicon

    International Nuclear Information System (INIS)

    Holland, S.

    1991-11-01

    A CMOS process that is compatible with silicon p-i-n radiation detectors has been developed and characterized. A total of twelve mask layers are used in the process. The NMOS device is formed in a retrograde well while the PMOS device is fabricated directly in the high-resistivity silicon. Isolation characteristics are similar to a standard foundary CMOS process. Circuit performance using 3 μm design rules has been evaluated. The measured propagation delay and power-delay product for a 51-stage ring oscillator was 1.5 ns and 43 fJ, respectively. Measurements on a simple cascode amplifier results in a gain-bandwidth product of 200 MHz at a bias current of 15 μA. The input-referred noise of the cascode amplifier is 20 nV/√Hz at 1 MHz

  8. Analysis of Uncertainty in a Middle-Cost Device for 3D Measurements in BIM Perspective

    Directory of Open Access Journals (Sweden)

    Alonso Sánchez

    2016-09-01

    Full Text Available Medium-cost devices equipped with sensors are being developed to get 3D measurements. Some allow for generating geometric models and point clouds. Nevertheless, the accuracy of these measurements should be evaluated, taking into account the requirements of the Building Information Model (BIM. This paper analyzes the uncertainty in outdoor/indoor three-dimensional coordinate measures and point clouds (using Spherical Accuracy Standard (SAS methods for Eyes Map, a medium-cost tablet manufactured by e-Capture Research & Development Company, Mérida, Spain. To achieve it, in outdoor tests, by means of this device, the coordinates of targets were measured from 1 to 6 m and cloud points were obtained. Subsequently, these were compared to the coordinates of the same targets measured by a Total Station. The Euclidean average distance error was 0.005–0.027 m for measurements by Photogrammetry and 0.013–0.021 m for the point clouds. All of them satisfy the tolerance for point cloud acquisition (0.051 m according to the BIM Guide for 3D Imaging (General Services Administration; similar results are obtained in the indoor tests, with values of 0.022 m. In this paper, we establish the optimal distances for the observations in both, Photogrammetry and 3D Photomodeling modes (outdoor and point out some working conditions to avoid in indoor environments. Finally, the authors discuss some recommendations for improving the performance and working methods of the device.

  9. A Simple Measurement of the Sliding Friction Coefficient

    Science.gov (United States)

    Gratton, Luigi M.; Defrancesco, Silvia

    2006-01-01

    We present a simple computer-aided experiment for investigating Coulomb's law of sliding friction in a classroom. It provides a way of testing the possible dependence of the friction coefficient on various parameters, such as types of materials, normal force, apparent area of contact and sliding velocity.

  10. Standard test method for calibration of surface/stress measuring devices

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1997-01-01

    Return to Contents page 1.1 This test method covers calibration or verification of calibration, or both, of surface-stress measuring devices used to measure stress in annealed and heat-strengthened or tempered glass using polariscopic or refractometry based principles. 1.2 This test method is nondestructive. 1.3 This test method uses transmitted light, and therefore, is applicable to light-transmitting glasses. 1.4 This test method is not applicable to chemically tempered glass. 1.5 Using the procedure described, surface stresses can be measured only on the “tin” side of float glass. 1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  11. Measuring Device for Air Speed in Macroporous Media and Its Application Inside Apple Storage Bins

    Directory of Open Access Journals (Sweden)

    Martin Geyer

    2018-02-01

    Full Text Available In cold storage facilities of fruit and vegetables, airflow is necessary for heat removal. The design of storage facilities influences the air speed in the surrounding of the product. Therefore, knowledge about airflow next to the product is important to plan the layout of cold stores adapted to the requirements of the products. A new sensing device (ASL, Air speed logger is developed for omnidirectional measurement of air speed between fruit or vegetables inside storage bins or in bulk. It consists of four interconnected plastic spheres with 80 mm diameter each, adapted to the size of apple fruit. In the free space between the spheres, silicon diodes are fixed for the airflow measurement based on a calorimetric principle. Battery and data logger are mounted inside the spheres. The device is calibrated in a wind tunnel in a measuring range of 0–1.3 m/s. Air speed measurements in fruit bulks on laboratory scale and in an industrial fruit store show air speeds in gaps between fruit with high stability at different airflow levels. Several devices can be placed between stored products for determination of the air speed distribution inside bulks or bin stacks in a storage room.

  12. Dynamic Calibration and Verification Device of Measurement System for Dynamic Characteristic Coefficients of Sliding Bearing

    Science.gov (United States)

    Chen, Runlin; Wei, Yangyang; Shi, Zhaoyang; Yuan, Xiaoyang

    2016-01-01

    The identification accuracy of dynamic characteristics coefficients is difficult to guarantee because of the errors of the measurement system itself. A novel dynamic calibration method of measurement system for dynamic characteristics coefficients is proposed in this paper to eliminate the errors of the measurement system itself. Compared with the calibration method of suspension quality, this novel calibration method is different because the verification device is a spring-mass system, which can simulate the dynamic characteristics of sliding bearing. The verification device is built, and the calibration experiment is implemented in a wide frequency range, in which the bearing stiffness is simulated by the disc springs. The experimental results show that the amplitude errors of this measurement system are small in the frequency range of 10 Hz–100 Hz, and the phase errors increase along with the increasing of frequency. It is preliminarily verified by the simulated experiment of dynamic characteristics coefficients identification in the frequency range of 10 Hz–30 Hz that the calibration data in this frequency range can support the dynamic characteristics test of sliding bearing in this frequency range well. The bearing experiments in greater frequency ranges need higher manufacturing and installation precision of calibration device. Besides, the processes of calibration experiments should be improved. PMID:27483283

  13. Device for measuring the two-dimensional distribution of a radioactive substance on a surface

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    A device is described by which, using a one-dimensional measuring proportional counter tube depending on position, one can measure the two-dimensionally distributed radioactivity of a surface and can plot this to scale two-dimensionally, after computer processing, or can show it two-dimensionally on a monitor. (orig.) [de

  14. A microfluidic dialysis device for complex biological mixture SERS analysis

    KAUST Repository

    Perozziello, Gerardo; Candeloro, Patrizio; Gentile, Francesco T.; Coluccio, Maria Laura; Tallerico, Marco; De Grazia, Antonio; Nicastri, Annalisa; Perri, Angela Mena; Parrotta, Elvira; Pardeo, Francesca; Catalano, Rossella; Cuda, Giovanni; Di Fabrizio, Enzo M.

    2015-01-01

    In this paper, we present a microfluidic device fabricated with a simple and inexpensive process allowing rapid filtering of peptides from a complex mixture. The polymer microfluidic device can be used for sample preparation in biological

  15. A Simple Flight Mill for the Study of Tethered Flight in Insects.

    Science.gov (United States)

    Attisano, Alfredo; Murphy, James T; Vickers, Andrew; Moore, Patricia J

    2015-12-10

    Flight in insects can be long-range migratory flights, intermediate-range dispersal flights, or short-range host-seeking flights. Previous studies have shown that flight mills are valuable tools for the experimental study of insect flight behavior, allowing researchers to examine how factors such as age, host plants, or population source can influence an insects' propensity to disperse. Flight mills allow researchers to measure components of flight such as speed and distance flown. Lack of detailed information about how to build such a device can make their construction appear to be prohibitively complex. We present a simple and relatively inexpensive flight mill for the study of tethered flight in insects. Experimental insects can be tethered with non-toxic adhesives and revolve around an axis by means of a very low friction magnetic bearing. The mill is designed for the study of flight in controlled conditions as it can be used inside an incubator or environmental chamber. The strongest points are the very simple electronic circuitry, the design that allows sixteen insects to fly simultaneously allowing the collection and analysis of a large number of samples in a short time and the potential to use the device in a very limited workspace. This design is extremely flexible, and we have adjusted the mill to accommodate different species of insects of various sizes.

  16. Measurement-device-independent quantum key distribution with correlated source-light-intensity errors

    Science.gov (United States)

    Jiang, Cong; Yu, Zong-Wen; Wang, Xiang-Bin

    2018-04-01

    We present an analysis for measurement-device-independent quantum key distribution with correlated source-light-intensity errors. Numerical results show that the results here can greatly improve the key rate especially with large intensity fluctuations and channel attenuation compared with prior results if the intensity fluctuations of different sources are correlated.

  17. Positioning device for MRI-guided high intensity focused ultrasound system

    Energy Technology Data Exchange (ETDEWEB)

    Damianou, Christakis [Frederick Institute of Technology (FIT), Limassol (Cyprus); MEDSONIC, LTD, Limassol (Cyprus); Ioannides, Kleanthis [Polikliniki Igia, Limassol (Cyprus); Milonas, Nicos [Frederick Institute of Technology (FIT), Limassol (Cyprus)

    2008-04-15

    A prototype magnetic resonance imaging (MRI)- compatible positioning device was used to move an MRI-guided high intensity focused ultrasound (HIFU) transducer. The positioning device has three user-controlled degrees of freedom that allow access to various targeted lesions. The positioning device was designed and fabricated using construction materials selected for compatibility with high magnetic fields and fast switching magnetic field gradients encountered inside MRI scanners. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, plastic sheets, brass screws, plastic pulleys and timing belts. The HIFU/MRI system includes the multiple subsystems (a) HIFU system, (b) MR imaging, (c) Positioning device (robot) and associate drivers, (d) temperature measurement, (e) cavitation detection, (f) MRI compatible camera, and (g) Soft ware. The MRI compatibility of the system was successfully demonstrated in a clinical high-field MRI scanner. The ability of the robot to accurately move the transducer thus creating discrete and overlapping lesions in biological tissue was tested successfully. A simple, cost effective, portable positioning device has been developed which can be used in virtually any clinical MRI scanner since it can be sited on the scanner's table. The propagation of HIFU can use either a lateral or superior-inferior approach. Discrete and large lesions were created successfully with reproducible results. (orig.)

  18. MEMS variable capacitance devices utilizing the substrate: I. Novel devices with a customizable tuning range

    KAUST Repository

    Elshurafa, Amro M.; El-Masry, Ezz I.

    2010-01-01

    , customizable, tuning ranges and/or ratios. The proposed structures can provide theoretical tuning ranges anywhere from 4.9 to 35 and from 3.4 to 26 respectively with a simple, yet effective, layout modification as opposed to the previously reported devices

  19. Inspection device in liquid

    International Nuclear Information System (INIS)

    Nagaoka, Etsuo.

    1996-01-01

    The present invention provides an inspection device in PWR reactor core in which inspection operations are made efficient by stabilizing a posture of the device in front-to-back, vertical and left-to-right directions by a simple structure. When the device conducts inspection while running in liquid, the front and the back directions of the device main body are inspected using a visual device while changing the posture by operating a front-to-back direction propulsion device and a right-to-left direction propulsion device, and a vertical direction propulsion device against to rolling, pitching and yawing of the device main body. In this case, a spherical magnet moves freely in the gravitational direction in a vibration-damping fluid in a non-magnetic spherical shell following the change of the posture of the device main body, in which the vibrations due to the movement of the spherical magnet is settled by the vibration-damping fluid thereby stabilizing the posture of the device main body. At a typical inspection posture, the settling effect is enhanced by the attraction force between the spherical magnets in the spherical shell and each of magnetic force-attracted magnetic members disposed to the outer circumference of the shell, and the posture of the device main body can be confirmed in front-to-back, right-to-left and vertical directions by each of the posture confirming magnetic sensors. (N.H.)

  20. An investigation of paper based microfluidic devices for size based separation and extraction applications.

    Science.gov (United States)

    Zhong, Z W; Wu, R G; Wang, Z P; Tan, H L

    2015-09-01

    Conventional microfluidic devices are typically complex and expensive. The devices require the use of pneumatic control systems or highly precise pumps to control the flow in the devices. This work investigates an alternative method using paper based microfluidic devices to replace conventional microfluidic devices. Size based separation and extraction experiments conducted were able to separate free dye from a mixed protein and dye solution. Experimental results showed that pure fluorescein isothiocyanate could be separated from a solution of mixed fluorescein isothiocyanate and fluorescein isothiocyanate labeled bovine serum albumin. The analysis readings obtained from a spectrophotometer clearly show that the extracted tartrazine sample did not contain any amount of Blue-BSA, because its absorbance value was 0.000 measured at a wavelength of 590nm, which correlated to Blue-BSA. These demonstrate that paper based microfluidic devices, which are inexpensive and easy to implement, can potentially replace their conventional counterparts by the use of simple geometry designs and the capillary action. These findings will potentially help in future developments of paper based microfluidic devices. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. A simple method of fabricating mask-free microfluidic devices for biological analysis.

    KAUST Repository

    Yi, Xin; Kodzius, Rimantas; Gong, Xiuqing; Xiao, Kang; Wen, Weijia

    2010-01-01

    We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper

  2. A silicon-on-insulator vertical nanogap device for electrical transport measurements in aqueous electrolyte solution

    Energy Technology Data Exchange (ETDEWEB)

    Strobel, Sebastian [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Arinaga, Kenji [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Hansen, Allan [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany); Tornow, Marc [Walter Schottky Institut, Technische Universitaet Muenchen, Am Coulombwall, D-85748 Garching (Germany)

    2007-07-25

    A novel concept for metal electrodes with few 10 nm separation for electrical conductance measurements in an aqueous electrolyte environment is presented. Silicon-on-insulator (SOI) material with 10 nm buried silicon dioxide serves as a base substrate for the formation of SOI plateau structures which, after recess-etching the thin oxide layer, thermal oxidation and subsequent metal thin film evaporation, feature vertically oriented nanogap electrodes at their exposed sidewalls. During fabrication only standard silicon process technology without any high-resolution nanolithographic techniques is employed. The vertical concept allows an array-like parallel processing of many individual devices on the same substrate chip. As analysed by cross-sectional TEM analysis the devices exhibit a well-defined material layer architecture, determined by the chosen material thicknesses and process parameters. To investigate the device in aqueous solution, we passivated the sample surface by a polymer layer, leaving a micrometre-size fluid access window to the nanogap region only. First current-voltage characteristics of a 65 nm gap device measured in 60 mM buffer solution reveal excellent electrical isolation behaviour which suggests applications in the field of biomolecular electronics in a natural environment.

  3. A simple and inexpensive retainer for overdenture prosthesis

    Science.gov (United States)

    Kumar, Lakshya; Rao, Jitendra; Yadav, Akanksha

    2013-01-01

    This article describes a clinical case report of a 65-year-old male patient in which an overdenture was fabricated by using a simple, logical and inexpensive means of retentive device. The described mandibular overdenture involves a simple modification in the coping design and a wire lock mechanism which was fabricated during denture processing. The problems associated with copings were overcome by putting the patient on a regimen wherein topical fluoride was applied every week on the abutment. The denture, fabricated involving a wire lock mechanism, was highly retentive and stable. Patient was highly satisfied with the outcome of the treatment. PMID:23861281

  4. Simple method based on intensity measurements for characterization of aberrations from micro-optical components.

    Science.gov (United States)

    Perrin, Stephane; Baranski, Maciej; Froehly, Luc; Albero, Jorge; Passilly, Nicolas; Gorecki, Christophe

    2015-11-01

    We report a simple method, based on intensity measurements, for the characterization of the wavefront and aberrations produced by micro-optical focusing elements. This method employs the setup presented earlier in [Opt. Express 22, 13202 (2014)] for measurements of the 3D point spread function, on which a basic phase-retrieval algorithm is applied. This combination allows for retrieval of the wavefront generated by the micro-optical element and, in addition, quantification of the optical aberrations through the wavefront decomposition with Zernike polynomials. The optical setup requires only an in-motion imaging system. The technique, adapted for the optimization of micro-optical component fabrication, is demonstrated by characterizing a planoconvex microlens.

  5. One-sided measurement-device-independent quantum key distribution

    Science.gov (United States)

    Cao, Wen-Fei; Zhen, Yi-Zheng; Zheng, Yu-Lin; Li, Li; Chen, Zeng-Bing; Liu, Nai-Le; Chen, Kai

    2018-01-01

    Measurement-device-independent quantum key distribution (MDI-QKD) protocol was proposed to remove all the detector side channel attacks, while its security relies on the trusted encoding systems. Here we propose a one-sided MDI-QKD (1SMDI-QKD) protocol, which enjoys detection loophole-free advantage, and at the same time weakens the state preparation assumption in MDI-QKD. The 1SMDI-QKD can be regarded as a modified MDI-QKD, in which Bob's encoding system is trusted, while Alice's is uncharacterized. For the practical implementation, we also provide a scheme by utilizing coherent light source with an analytical two decoy state estimation method. Simulation with realistic experimental parameters shows that the protocol has a promising performance, and thus can be applied to practical QKD applications.

  6. Development of a wearable plantar force measurement device for gait analysis in remote conditions.

    Science.gov (United States)

    Hamid, Rawnak; Wijesundara, Suharshani; McMillan, Lachlan; Scott, David; Redoute, Jean-Michel; Ebeling, Peter R; Yuce, Mehmet Rasit

    2017-07-01

    The pressure field that exists between the foot and the supporting surface is identified as the foot plantar pressure. The information obtained from foot plantar pressure measurements has useful applications that include diagnosis of gait disturbances, optimization of footwear design, sport biomechanics and prevention of injury. Using wearable technology to measure foot plantar pressure continuously allows the collection of comprehensive real-life data sets while interfering minimally with the subject's daily activities. This paper presents the design of a wearable device to measure foot plantar pressure. Mechanical and electrical design considerations as well as data analysis are discussed. A pilot study involving 20 physically fit volunteers (15 males and 5 females, ageing from 20 - 45) performing a variety of physical activities (such as standing, walking, jumping and climbing up and down stairs) illustrate the potential of the device in terms of its wearability, and suitability for unobtrusive long-term monitoring.

  7. Development of signal acquisition device of rotating coil measurement system

    International Nuclear Information System (INIS)

    Zhou Jianxin; Li Li; Kang Wen; Deng Chengdong; Yin Baogui; Fu Shinian

    2013-01-01

    A new rotating coil magnetic measurement system using the technical solution of the combination of a dynamic signal acquisition card and software with specific functions was developed. The acquisition device of the system successfully implemented the function of the PDI-5025 integrator. The sampling rate, the range, the accuracy and the flexibility of the system were improved. The development program of signal acquisition equipment, the realization of the acquisition function and the reliability and stability of the system were introduced. (authors)

  8. A simple device for subsectioning aqueous sediments from the box or spade corer

    Digital Repository Service at National Institute of Oceanography (India)

    Valsangkar, A.B.

    , combination of any sub-section interval is possible; however, the care to be taken in selecting the appropriate size rings. Results and discussion The proposed apparatus/device has been successfully tested and used5 for the first time during 38th... PVC liners (12.5 cm OD, and 50 cm length), and 2 PVC liners (10 cm OD and 50 cm length) (Figure 1). The sub-cores were carefully removed from the box by inserting a PVC disk at the bottom. The sub-core was then placed on the top of the device...

  9. Nonlinear surface impedance of YBCO thin films: Measurements, modeling, and effects in devices

    International Nuclear Information System (INIS)

    Oates, D.E.; Koren, G.; Polturak, E.

    1995-01-01

    High-T c thin films continue to be of interest for passive device applications at microwave frequencies, but nonlinear effects may limit the performance. To understand these effects we have measured the nonlinear effects may limit the performance. To understand these effects we have measured the nonlinear surface impedance Z s in a number of YBa 2 Cu 3 O 7-x thin films as a function of frequency from 1 to 18 GHz, rf surface magnetic field H rf to 1500 Oe, and temperature from 4 K to T c . The results at low H rf are shown to agree quantitatively with a modified coupled-grain model and at high H rf with hysteresis-loss calculations using the Bean critical-state model applied to a thin strip. The loss mechanisms are extrinsic properties resulting from defects in the films. We also report preliminary measurements of the nonlinear impedance of Josephson junctions, and the results are related to the models of nonlinear Z s . The implications of nonlinear Z s for devices are discussed using the example of a five-pole bandpass filter

  10. — study of the use of two standard- and non-standard-measuring devices

    Directory of Open Access Journals (Sweden)

    Paweł Ostapkowicz

    2014-03-01

    Full Text Available This paper deals with leak detection in liquid transmission pipelines. Diagnostic method based on negative pressure wave detection is taken into account here. The paper focuses on variant of this method, related to the use of only two measurement points (devices, placed at the inlet and outlet of the pipeline. Standard transducers for measurement of pressure signals and non-standard elaborated technique for measurement of new diagnostic signals were used. New diagnostic signals, conventionally named the signals of weak interactions, result from the work of special devices (correctors joined to the pipeline. In order to compare both hardware solutions key performance attributes for the analyzed leak detection method were determined. The bases of such assessment were experimental tests. They were conducted with the use of a physical model of a pipeline. The pipeline was 380 meters long, 34 mm in internal diameter and made of polyethylene (PEHD pipes. The medium pumped through the pipeline was water. Carrying out such research, diagnostic procedures elaborated by the author were used and tested.[b]Keywords[/b]: technical diagnostics, pipelines, leak detection

  11. Portable blood extraction device integrated with biomedical monitoring system

    Science.gov (United States)

    Khumpuang, S.; Horade, M.; Fujioka, K.; Sugiyama, S.

    2006-01-01

    Painless and portable blood extraction device has been immersed in the world of miniaturization on bio-medical research particularly in manufacturing point-of-care systems. The fabrication of a blood extraction device integrated with an electrolyte-monitoring system is reported in this paper. The device has advantages in precise controlled dosage of blood extracted including the slightly damaged blood vessels and nervous system. The in-house blood diagnostic will become simple for the patients. Main components of the portable system are; the blood extraction device and electrolyte-monitoring system. The monitoring system consists of ISFET (Ion Selective Field Effect Transistor) for measuring the concentration level of minerals in blood. In this work, we measured the level of 3 ions; Na+, K+ and Cl-. The mentioned ions are frequently required the measurement since their concentration levels in the blood can indicate whether the kidney, pancreas, liver or heart is being malfunction. The fabrication of the whole system and experimentation on each ISM (Ion Sensitive Membrane) will be provided. Taking the advantages of LIGA technology, the 100 hollow microneedles fabricated by Synchrotron Radiation deep X-ray lithography through PCT (Plane-pattern to Cross-section Transfer) technique have been consisted in 5x5 mm2 area. The microneedle is 300 μm in base-diameter, 500 μm-pitch, 800 μm-height and 50 μm hole-diameter. The total size of the blood extraction device is 2x2x2 cm 3. The package is made from a plastic socket including slots for inserting microneedle array and ISFET connecting to an electrical circuit for the monitoring. Through the dimensional design for simply handling and selection of disposable material, the patients can self-evaluate the critical level of the body minerals in anywhere and anytime.

  12. Development, validation and application of a device to measure e-cigarette users’ puffing topography

    Science.gov (United States)

    Cunningham, Anthony; Slayford, Sandra; Vas, Carl; Gee, Jodie; Costigan, Sandra; Prasad, Krishna

    2016-01-01

    With the rapidly rising popularity and substantial evolution of electronic cigarettes (e-cigarettes) in the past 5–6 years, how these devices are used by vapers and consumers’ exposure to aerosol emissions need to be understood. We used puffing topography to measure directly product use. We adapted a cigarette puffing topography device for use with e-cigarettes. We performed validation using air and e-cigarette aerosol under multiple regimes. Consumer puffing topography was measured for 60 vapers provided with rechargeable “cig-a-like” or larger button-activated e-cigarettes, to use ad-libitum in two sessions. Under all regimes, air puff volumes were within 1 mL of the target and aerosol volumes within 5 mL for all device types, serving to validate the device. Vapers’ mean puff durations (2.0 s and 2.2 s) were similar with both types of e-cigarette, but mean puff volumes (52.2 mL and 83.0 mL) and mean inter-puff intervals (23.2 s and 29.3 s) differed significantly. The differing data show that product characteristics influence puffing topography and, therefore, the results obtained from a given e-cigarette might not read across to other products. Understanding the factors that affect puffing topography will be important for standardising testing protocols for e-cigarette emissions. PMID:27721496

  13. A simple technique for measuring the superconducting critical temperature of small (>= 10 μg) samples

    International Nuclear Information System (INIS)

    Pereira, R.F.R.; Meyer, E.; Silveira, M.F. da.

    1983-01-01

    A simple technique for measuring the superconducting critical temperature of small (>=10μg) samples is described. The apparatus is built in the form of a probe, which can be introduced directly into a liquid He storage dewar and permits the determination of the critical temperature, with an imprecision of +- 0.05 K above 4.2 K, in about 10 minutes. (Author) [pt

  14. Polymer electronic devices and materials.

    Energy Technology Data Exchange (ETDEWEB)

    Schubert, William Kent; Baca, Paul Martin; Dirk, Shawn M.; Anderson, G. Ronald; Wheeler, David Roger

    2006-01-01

    Polymer electronic devices and materials have vast potential for future microsystems and could have many advantages over conventional inorganic semiconductor based systems, including ease of manufacturing, cost, weight, flexibility, and the ability to integrate a wide variety of functions on a single platform. Starting materials and substrates are relatively inexpensive and amenable to mass manufacturing methods. This project attempted to plant the seeds for a new core competency in polymer electronics at Sandia National Laboratories. As part of this effort a wide variety of polymer components and devices, ranging from simple resistors to infrared sensitive devices, were fabricated and characterized. Ink jet printing capabilities were established. In addition to promising results on prototype devices the project highlighted the directions where future investments must be made to establish a viable polymer electronics competency.

  15. 77 FR 17457 - Work Group on Alternative Test Methods for Commercial Measuring Devices

    Science.gov (United States)

    2012-03-26

    ... DEPARTMENT OF COMMERCE National Institute of Standards and Technology Work Group on Alternative... Work Group (WG) to examine alternative methods for testing the accuracy of commercial measuring devices... participates to promote uniformity among the states in laws, regulations, methods, and testing equipment that...

  16. Measuring device for the spatial neutron density distribution within a nuclear reactor

    International Nuclear Information System (INIS)

    Fracke, A.; Wachtler, H.

    1974-01-01

    A solid probe in a pneumatic tube is lead from the core to a measuring device outside the pressure vessel and reversely, in order to measure the local neutron density distribution inside a reactor core. The activiable solid probe is in the form of a steel spiral spring with densely open coils and semi-spherical end pieces. A good curve negotiating characteristic of the measuring probe and defined duration times are secured in the reactor core. Furthermore, the interior of the spiral can be filled with a lubricating medium, e.g. molybdenum sulphite, so that a better sliding of the measuring probe into the tubes of the pneumatic tube is ensured. (DG) [de

  17. A simple route to synthesize manganese germanate nanorods

    International Nuclear Information System (INIS)

    Pei, L.Z.; Yang, Y.; Yuan, C.Z.; Duan Taike; Zhang Qianfeng

    2011-01-01

    Manganese germanate nanorods have been synthesized by a simple route using germanium dioxide and manganese acetate as the source materials. X-ray diffraction observation shows that the nanorods are composed of orthorhombic and monoclinic manganese germanate phases. Scanning electron microscopy and transmission electron microscopy observations display that the manganese germanate nanorods have flat tips with the length of longer than 10 micrometers and diameter of 60-350 nm, respectively. The role of the growth conditions on the formation of the manganese germanate nanorods shows that the proper selection and combination of the growth conditions are the key factor for controlling the formation of the manganese germanate nanorods. The photoluminescence spectrum of the manganese germanate nanorods exhibits four fluorescence emission peaks centered at 422 nm, 472 nm, 487 nm and 530 nm showing the application potential for the optical devices. - Research Highlights: → Manganese germanate nanorods have been synthesized by simple hydrothermal process. → The formation of manganese germanate nanorods can be controlled by growth conditions. → Manganese germanate nanorods exhibit good PL emission ability for optical device.

  18. A cost-effective assay for antioxidant using simple cotton thread combining paper based device with mobile phone detection.

    Science.gov (United States)

    Sateanchok, Suphasinee; Wangkarn, Sunanta; Saenjum, Chalermpong; Grudpan, Kate

    2018-01-15

    A cost-effective assay for antioxidant using simple cotton thread combining paper based device with mobile phone detection has been investigated. Standard and sample solutions flow along a bunch of cotton thread treated with sodium hydroxide via microfluidic behaviors without external pumping. The analyte solution reacts with the reagents that have been immobilized on the paper strip fixed at the end of the cotton bunch. The developed platforms were used for the assays of total phenolic content and antioxidant capacity by employing Folin-Ciocalteu and 2, 2-diphenyl-1-picryhydrazyl (DPPH) respectively. Simple detection can be made by employing a mobile phone camera (iPhone 4S) with Image J or Photoshop for image processing and evaluation. Gallic acid was used as a reference standard in this work, as its polyphenol structures can be found in many plants. The total phenolic content is expressed as gallic acid equivalents (GAE) (mg/g material). Inhibition capacity is calculated by the equation: % I = [(I o - I s )/ I o ] × 100, where I s is the relative magenta intensity (CMYK mode) of sample, and I o the relative magenta intensity of DPPH•. IC 50 inhibition can be estimated from the graph and can be used for the antioxidant capacity consideration. Applications to the assay green tea samples were demonstrated. The total phenolic contents in the green tea samples were found to be 48-105mg/g, with %RSD of less than 10 for that of higher 50 GAE mg/g and IC 50 values of the samples studied were 25-50mg/L. The results obtained by the developed methods agree with that of the standard methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Medically relevant assays with a simple smartphone and tablet based fluorescence detection system.

    Science.gov (United States)

    Wargocki, Piotr; Deng, Wei; Anwer, Ayad G; Goldys, Ewa M

    2015-05-20

    Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera) and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  20. Medically Relevant Assays with a Simple Smartphone and Tablet Based Fluorescence Detection System

    Directory of Open Access Journals (Sweden)

    Piotr Wargocki

    2015-05-01

    Full Text Available Cell phones and smart phones can be reconfigured as biomedical sensor devices but this requires specialized add-ons. In this paper we present a simple cell phone-based portable bioassay platform, which can be used with fluorescent assays in solution. The system consists of a tablet, a polarizer, a smart phone (camera and a box that provides dark readout conditions. The assay in a well plate is placed on the tablet screen acting as an excitation source. A polarizer on top of the well plate separates excitation light from assay fluorescence emission enabling assay readout with a smartphone camera. The assay result is obtained by analysing the intensity of image pixels in an appropriate colour channel. With this device we carried out two assays, for collagenase and trypsin using fluorescein as the detected fluorophore. The results of collagenase assay with the lowest measured concentration of 3.75 µg/mL and 0.938 µg in total in the sample were comparable to those obtained by a microplate reader. The lowest measured amount of trypsin was 930 pg, which is comparable to the low detection limit of 400 pg for this assay obtained in a microplate reader. The device is sensitive enough to be used in point-of-care medical diagnostics of clinically relevant conditions, including arthritis, cystic fibrosis and acute pancreatitis.

  1. Performance test of dual modulator polarimeters in two different configurations for magneto-optic measurement of fusion devices

    International Nuclear Information System (INIS)

    Kenji Higuchi; Tsuyoshi Akiyama; Yoshifumi Azuma; Shunji Tsuji-Iio; Hiroaki Tsutsui; Ryuichi Shimada

    2006-01-01

    Accurate measurement of the magnetic field around plasma is indispensable for real-time control and data analysis on magnetic fusion devices such as tokamaks. Instead of commonly used pick-up loops, which have the problems of zero-point drifts, we proposed and tested a magneto-optic polarimeter based on the polarization modulation method using two photoelastic modulators (PEMs). Polarization detection using a pair of PEMs has been applied to the motional Stark effect (MSE) measurements in some tokamaks. The CO 2 laser polarimeter for electron density measurement on JT-60U adopted this method and demonstrated long time stability for several hours. However, this method requires the same number of pairs of PEMs, which are delicate and expensive, as that of channels so that this method is not easy to apply to multi-point measurements of magnetic fields around tokamaks. To cope with this problem, the two PEMs, which are conventionally placed behind each magnetic sensor, are used to modulate the incident beam before split for each magneto-optic sensor. This configuration can reduce the number of PEMs drastically and the optical system becomes simple. In this new optical configuration, the polarization angle resolution comparable to the conventional optical configuration of 0.002 o with response time of 10 ms was achieved at an incident polarization angle of about 0 o while that at 21 o was 0.07 o . The resolution of 0.07 o corresponds to 7 gauss when a 40-mm-long ZnSe sensing rod is used. Performance test between the two optical configurations were also made on the long-time stability and the accuracy with increasing numbers of beam splitters and/or mirrors for multi-point measurements. (author)

  2. α-spectrometric device equipped with semi-conductors for direct measurement of transuranium elements on large area filters

    International Nuclear Information System (INIS)

    Fessler, H.; Pawelzik, J.

    1984-10-01

    A device was developed with an array of 8 silicon surface barrier detectors inside a vacuum chamber containing a rotating sample holder for large areas (200 mm diameter) aerosol filters. It serves for quick identification of α-emitters on these aerosol filters, and allows to measure the α-particles with a relatively constant efficiency along a filter diameter. Thus, the radiochemical treatment of single filters can be avoided. Troubles appeared in the course of development of defective semiconductors and their temperature dependence. To suppress the influence of temperature a cooling device was built. During practical testing a cross-efficiency of 13.6% was measured. It is possible to identify α-emitting nuclides with an activity of 10 -1 Bq per sample during about 2 hours of measuring time. Appropriate methodes of calculation are indicated. The data output of the device is suited for transfer to a computer. (orig./HP) [de

  3. Fiscal 1998 achievement report on regional consortium research and development project. Venture business fostering regional consortium--Creation of key industries (Development of trace pollutant measuring device); 1998 nendo biryo kankyo busshitsu sokutei device no kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    For measuring trace pollutants and for establishing a simplified high-speed method of assessing their impacts, research and development efforts are exerted to build measuring devices to meet the purpose. In relation with air pollutants, researches are conducted to develop a passive sampler technology-aided measuring devices capable of on-site analyses of trace pollutants. For the development of microchips to be the nuclei of such devices, studies are conducted about a gas absorbing chip consisting of porous quartz glass and a passive sampler installed thereon, a chemical reaction chip on which absorbed NO{sub 2} ions react with a fluorescent reagent, and an optical detection chip capable of high-sensitivity detection of a fluorescent substance generated by an ultraviolet emission device. As the result, an A4 size prototype of a trace NO{sub 2} measuring device is developed using a fluorescence detecting microchip system. In addition, a simplified measuring device is developed, in which gas absorbed at a polymer film flows in a very thin plastic-formed channel to reach an electrochemical detection system for measurement, and the device is found to work effectively. (NEDO)

  4. A Simple Method of Spectrum Processing for β-ray Measurement without Pretreatment

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jun Woo; Kim, Hee Reyoung [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    Radioactivity analysis of β-emitting radionuclide is important because of its dangerousness of overexposure. γ-ray has been measured by conventional detector such as NaI(Tl) or high purity germanium (HPGe) detector. But β-ray is hard to detect by those detectors because of its short range. Therefore, liquid scintillation counter (LSC) has been used to measure the radioactivity of pure beta emitter but there is huge problem of organic waste production, though LSC has high efficiency for detection of low energy β-ray. To solve this problem, characterization of β-ray measurement in a plastic scintillator was carried out in this study. There have been some studies about plastic scintillator to measure the β-rays without liquid scintillation method. Plastic scintillator has benefits for detection of β-ray because it has relative low effective atomic number. β-ray and γ-ray spectra in cylindrical plastic scintillator was analyzed and a method of separation of β-ray spectrum was suggested. A simple method of β-ray spectrum separation was suggested. The method was verified by chi-square method to estimate the difference between calculated and measured spectrum. This method was successfully applied by using disc source. For future works, practical radioactive source will be used to acquire the pulse height spectrum. The method can be used for measurement of pure β emitter without pretreatment if this method is verified for practical purpose.

  5. A simple and accurate onset detection method for a measured bell-shaped speed profile

    Directory of Open Access Journals (Sweden)

    Lior Botzer

    2009-06-01

    Full Text Available Motor control neuroscientists measure limb trajectories and extract the onset of the movement for a variety of purposes. Such trajectories are often aligned relative to the onset of individual movement before the features of that movement are extracted and their properties are inspected. Onset detection is performed either manually or automatically, typically by selecting a velocity threshold. Here, we present a simple onset detection algorithm that is more accurate than the conventional velocity threshold technique. The proposed method is based on a simple regression and follows the minimum acceleration with constraints model, in which the initial phase of the bell-shaped movement is modeled by a cubic power of the time. We demonstrate the performance of the suggested method and compare it to the velocity threshold technique and to manual onset detection by a group of motor control experts. The database for this comparison consists of simulated minimum jerk trajectories and recorded reaching movements.

  6. Surface EMG and intra-socket force measurement to control a prosthetic device

    Science.gov (United States)

    Sanford, Joe; Patterson, Rita; Popa, Dan

    2015-06-01

    Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.

  7. Characterisation of a micro-plasma device sensor using electrical measurements and emission spectroscopy

    International Nuclear Information System (INIS)

    Mariotti, D.

    2002-04-01

    This thesis reports on research undertaken on the characterisation of a micro-plasma device to be used for gas analysis by mean of plasma emission spectroscopy. The work covers aspects related to the micro-plasma electrical and optical emission parameters, and their importance for the utilisation of the micro-plasma device in gas analysis. Experimental results have been used to analyse the fundamental micro-plasma processes and to develop a model, which could provide additional information. This dissertation contains a general literature review of topics related to plasma physics, plasma emission spectroscopy, gas analysis (chemical analysis and artificial olfaction) and other micro-plasma applications. Experimental work focuses on two main areas: electrical measurements and emission measurements. Firstly, electrical measurements are taken and interpretations are given. Where necessary, new theoretical treatments are suggested in order to describe better the physical phenomena. Plasma emission has been considered under different working conditions. This allowed the characterisation of the micro-plasma emission and also a better understanding of the micro-plasma processes. On the basis of the experimental data obtained and other assumptions a model has been developed. A computer simulation based on this model provided additional useful information on the micro- plasma behaviour. The first fundamental implication of this new research is the peculiar behaviour of the micro-plasma. This micro-plasma exhibited deviations from Paschen law and strong dependency on cathode material, which contributed to the formation of a low current stable regime. These results have been followed by physical interpretations and theoretical descriptions. The second implication is the establishment of the boundaries and of the influencing parameters for plasma emission spectroscopy as an analytical tool in this particular micro-plasma. From the applied perspective this study has shown that

  8. Development of Gravity Acceleration Measurement Using Simple Harmonic Motion Pendulum Method Based on Digital Technology and Photogate Sensor

    Science.gov (United States)

    Yulkifli; Afandi, Zurian; Yohandri

    2018-04-01

    Development of gravitation acceleration measurement using simple harmonic motion pendulum method, digital technology and photogate sensor has been done. Digital technology is more practical and optimizes the time of experimentation. The pendulum method is a method of calculating the acceleration of gravity using a solid ball that connected to a rope attached to a stative pole. The pendulum is swung at a small angle resulted a simple harmonic motion. The measurement system consists of a power supply, Photogate sensors, Arduino pro mini and seven segments. The Arduino pro mini receives digital data from the photogate sensor and processes the digital data into the timing data of the pendulum oscillation. The calculation result of the pendulum oscillation time is displayed on seven segments. Based on measured data, the accuracy and precision of the experiment system are 98.76% and 99.81%, respectively. Based on experiment data, the system can be operated in physics experiment especially in determination of the gravity acceleration.

  9. MELLO: Medical lifelog ontology for data terms from self-tracking and lifelog devices.

    Science.gov (United States)

    Kim, Hye Hyeon; Lee, Soo Youn; Baik, Su Youn; Kim, Ju Han

    2015-12-01

    The increasing use of health self-tracking devices is making the integration of heterogeneous data and shared decision-making more challenging. Computational analysis of lifelog data has been hampered by the lack of semantic and syntactic consistency among lifelog terms and related ontologies. Medical lifelog ontology (MELLO) was developed by identifying lifelog concepts and relationships between concepts, and it provides clear definitions by following ontology development methods. MELLO aims to support the classification and semantic mapping of lifelog data from diverse health self-tracking devices. MELLO was developed using the General Formal Ontology method with a manual iterative process comprising five steps: (1) defining the scope of lifelog data, (2) identifying lifelog concepts, (3) assigning relationships among MELLO concepts, (4) developing MELLO properties (e.g., synonyms, preferred terms, and definitions) for each MELLO concept, and (5) evaluating representative layers of the ontology content. An evaluation was performed by classifying 11 devices into 3 classes by subjects, and performing pairwise comparisons of lifelog terms among 5 devices in each class as measured using the Jaccard similarity index. MELLO represents a comprehensive knowledge base of 1998 lifelog concepts, with 4996 synonyms for 1211 (61%) concepts and 1395 definitions for 926 (46%) concepts. The MELLO Browser and MELLO Mapper provide convenient access and annotating non-standard proprietary terms with MELLO (http://mello.snubi.org/). MELLO covers 88.1% of lifelog terms from 11 health self-tracking devices and uses simple string matching to match semantically similar terms provided by various devices that are not yet integrated. The results from the comparisons of Jaccard similarities between simple string matching and MELLO matching revealed increases of 2.5, 2.2, and 5.7 folds for physical activity,body measure, and sleep classes, respectively. MELLO is the first ontology for

  10. A self-loading microfluidic device for determining the minimum inhibitory concentration of antibiotics.

    Science.gov (United States)

    Cira, Nate J; Ho, Jack Y; Dueck, Megan E; Weibel, Douglas B

    2012-03-21

    This article describes a portable microfluidic technology for determining the minimum inhibitory concentration (MIC) of antibiotics against bacteria. The microfluidic platform consists of a set of chambers molded in poly(dimethylsiloxane) (PDMS) that are preloaded with antibiotic, dried, and reversibly sealed to a second layer of PDMS containing channels that connect the chambers. The assembled device is degassed via vacuum prior to its use, and the absorption of gas by PDMS provides the mechanism for actuating and metering the flow of fluid in the microfluidic channels and chambers. During the operation of the device, degas driven flow introduces a suspension of bacterial cells, dissolves the antibiotic, and isolates cells in individual chambers without cross contamination. The growth of bacteria in the chambers in the presence of a pH indicator produces a colorimetric change that can be detected visually using ambient light. Using this device we measured the MIC of vancomycin, tetracycline, and kanamycin against Enterococcus faecalis 1131, Proteus mirabilis HI4320, Klebsiella pneumoniae, and Escherichia coli MG1655 and report values that are comparable to standard liquid broth dilution measurements. The device provides a simple method for MIC determination of individual antibiotics against human pathogens that will have applications for clinical and point-of-care medicine. Importantly, this device is designed around simplicity: it requires a single pipetting step to introduce the sample, no additional components or external equipment for its operation, and provides a straightforward visual measurement of cell growth. As the device introduces a novel approach for filling and isolating dead-end microfluidic chambers that does not require valves and actuators, this technology should find applications in other portable assays and devices.

  11. An Exploratory Study to Measure Excessive Involvement in Multitasking Interaction with Smart Devices.

    Science.gov (United States)

    Zhang, Yubo; Rau, Pei-Luen Patrick

    2016-06-01

    This study developed a scale measuring excessive involvement in multitasking interaction with smart devices. An online questionnaire was designed and surveyed in a sample of 380 respondents. The sample was split into two groups for exploratory and confirmatory factor analysis, respectively. A four-factor structure was identified with an acceptable goodness of fit. The first two factors, "Obsession and neglect" and "Problematic control," described the obsessive feelings, neglect behaviors, and behavior control problems accompanied by excessive multitasking interaction with smart devices. The latter two factors, "Multitasking preference" and "Polychronic orientation," referred to multitaskers' preference of engaging in multiple media use or interaction tasks rather than a single task from the time orientation perspective. The four-factor structure indicates that excessive involvement in multitasking interaction with smart devices shares some similarities with other behavioral addiction types, but demonstrates uniqueness compared with excessive engagement in single media use.

  12. Contactless graphene conductance measurements: the effect of device fabrication on terahertz time-domain spectroscopy

    DEFF Research Database (Denmark)

    Mackenzie, David; Buron, Jonas Christian Due; Bøggild, Peter

    2016-01-01

    We perform contactless full-wafer maps of the electrical conductance of a 4-inch wafer of single-layer CVD graphene using terahertz time-domain spectroscopy both before and after deposition of metal contacts and fabrication of devices via laser ablation. We find that there is no significant change...... in the measured conductance of graphene before and after device fabrication. We also show that precise terahertz time-domain spectroscopy can be performed when the beam spot is at sufficient distance (>1.2 mm) from metal contacts....

  13. Validity of a Simple Method for Measuring Force-Velocity-Power Profile in Countermovement Jump.

    Science.gov (United States)

    Jiménez-Reyes, Pedro; Samozino, Pierre; Pareja-Blanco, Fernando; Conceição, Filipe; Cuadrado-Peñafiel, Víctor; González-Badillo, Juan José; Morin, Jean-Benoît

    2017-01-01

    To analyze the reliability and validity of a simple computation method to evaluate force (F), velocity (v), and power (P) output during a countermovement jump (CMJ) suitable for use in field conditions and to verify the validity of this computation method to compute the CMJ force-velocity (F-v) profile (including unloaded and loaded jumps) in trained athletes. Sixteen high-level male sprinters and jumpers performed maximal CMJs under 6 different load conditions (0-87 kg). A force plate sampling at 1000 Hz was used to record vertical ground-reaction force and derive vertical-displacement data during CMJ trials. For each condition, mean F, v, and P of the push-off phase were determined from both force-plate data (reference method) and simple computation measures based on body mass, jump height (from flight time), and push-off distance and used to establish the linear F-v relationship for each individual. Mean absolute bias values were 0.9% (± 1.6%), 4.7% (± 6.2%), 3.7% (± 4.8%), and 5% (± 6.8%) for F, v, P, and slope of the F-v relationship (S Fv ), respectively. Both methods showed high correlations for F-v-profile-related variables (r = .985-.991). Finally, all variables computed from the simple method showed high reliability, with ICC >.980 and CV push-off distance, and jump height are known.

  14. Measurements within cloud cavitation by means of X-ray attenuation device

    International Nuclear Information System (INIS)

    Barouch, G.; Legoupil, S.; Stutz, B.; Woo, R.

    2004-01-01

    The purpose of this work is to describe the two-phase flow structure of cloud cavitation. The experimental study is performed in a cavitation tunnel equipped with a Venturi-type test section. The flow is investigated by means of an optical probe and a X-ray attenuation device. 24 collimated detectors enable measurement of the instantaneous space fraction of the vapour phase at different locations of the two-phase flow. X-ray intensity measurement mode enables fast data acquisitions (250 Hz). The studied geometry is characterized by a convergent angle of 18 deg. and a divergent angle of 8 deg. It leads to regular large vapour cloud shedding

  15. Overview of gamma spectrometry measurement devices developed by ENVINET a.s

    International Nuclear Information System (INIS)

    Sidlova, V.; Slama, L.; Holecek, V.; Chaloupkova, H.

    2008-01-01

    This paper demonstrates the development and usage of the devices designed for non- destructive radiological characterization of radioactive waste. All ..systems are based on gamma-spectrometry and are divided into two categories - stable and mobile. Stable ones involve only measurement in fixed detector - package configuration. They are used for assessment of packaged waste, mainly in drums. Mobile ones are flexible and allow measurement of a wide range of objects from various positions and can be also transported to arbitrary location. The calibration of such systems is performed by means of appropriate software which allows computation of full-energy peak efficiency in various configurations. (authors)

  16. Surface Passivation for Reliable Measurement of Bulk Electronic Properties of Heterojunction Devices.

    Science.gov (United States)

    Bissig, Benjamin; Guerra-Nunez, Carlos; Carron, Romain; Nishiwaki, Shiro; La Mattina, Fabio; Pianezzi, Fabian; Losio, Paolo A; Avancini, Enrico; Reinhard, Patrick; Haass, Stefan G; Lingg, Martina; Feurer, Thomas; Utke, Ivo; Buecheler, Stephan; Tiwari, Ayodhya N

    2016-10-01

    Quantum efficiency measurements of state of the art Cu(In,Ga)Se 2 (CIGS) thin film solar cells reveal current losses in the near infrared spectral region. These losses can be ascribed to inadequate optical absorption or poor collection of photogenerated charge carriers. Insight on the limiting mechanism is crucial for the development of more efficient devices. The electron beam induced current measurement technique applied on device cross-sections promises an experimental access to depth resolved information about the charge carrier collection probability. Here, this technique is used to show that charge carrier collection in CIGS deposited by multistage co-evaporation at low temperature is efficient over the optically active region and collection losses are minor as compared to the optical ones. Implications on the favorable absorber design are discussed. Furthermore, it is observed that the measurement is strongly affected by cross-section surface recombination and an accurate determination of the collection efficiency is not possible. Therefore it is proposed and shown that the use of an Al 2 O 3 layer deposited onto the cleaved cross-section significantly improves the accuracy of the measurement by reducing the surface recombination. A model for the passivation mechanism is presented and the passivation concept is extended to other solar cell technologies such as CdTe and Cu 2 (Zn,Sn)(S,Se) 4 . © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Development of a Force Measurement Device for Lower-Body Muscular Strength Measuring of Skaters

    Science.gov (United States)

    Kim, Dong Ki; Lee, Jeong Tae

    This paper presents a force measurement system that can measure a lower-body muscular strength of skaters. The precise measurement and analysis of the left and right lower-body strength of skaters is necessary, because a left/right lower-body strength balance is helpful to improve the athletes' performance and to protect them from injury. The system is constructed with a skate sliding board, a couple of sensor-units with load cell, indicator and control box, guard, force pad, and support bracket. The developed force measurement system is calibrated by the calibration setup, and the uncertainty of the force sensing unit on the left is within 0.087% and the uncertainty of the force sensing unit on the right is within 0.109%. In order to check the feasibility of the developed measurement device, a kinematic analysis is conducted with skater. As a result, the subject shows the deviation of left and right of 12.1 N with respect to average strength and 39.1 N with respect to the maximum strength. This evaluation results are reliable enough to make it possible to measure a lower-body muscular strength of skaters. The use of this measurement system will be expected to correct the posture of skaters and record the sports dynamics data for each athlete. It is believed that through the development of this equipment, skaters in elementary, middle, high schools, colleges, and the professional level have the systematic training to compete with world-class skaters.

  18. Simple, cost effective & result oriented framework for supplier performance measurement in sports goods manufacturing industry

    Directory of Open Access Journals (Sweden)

    2011-09-01

    Full Text Available The emergences of global markets have increased competition worldwide. For the Sports Goods Manufacturing Industry which is considered to be an intensive supplier base industry with limited resources to sustain in what is already a very competitive market there is a need for the entire supply chain viz. raw material and machinery suppliers and manufacturers to measure their supplier's performance to reduce business risks and revenue losses. How to design & execute a simple, cost effective & result oriented Framework for Supplier Performance Measurement for sports goods manufacturing small - medium enterprises is the main aim of this research paper.

  19. Rack Protection Monitor - A Simple System

    International Nuclear Information System (INIS)

    Orr, S.

    1997-12-01

    The Rack Protection Monitor is a simple, fail-safe device to monitor smoke, temperature and ventilation sensors. It accepts inputs from redundant sensors and has a hardwired algorithm to prevent nuisance power trips due to random sensor failures. When a sensor is triggered the Rack Protection Monitor latches and annunicates the alarm. If another sensor is triggered, the Rack Protection Monitor locally shuts down the power to the relay rack and sends alarm to central control

  20. A simple method to measure cell viability in proliferation and cytotoxicity assays

    Directory of Open Access Journals (Sweden)

    Ricardo Carneiro Borra

    2009-09-01

    Full Text Available Resazurin dye has been broadly used as indicator of cell viability in several types of assays for evaluation of the biocompatibility of medical and dental materials. Mitochondrial enzymes, as carriers of diaphorase activities, are probably responsible for the transference of electrons from NADPH + H+ to resazurin, which is reduced to resorufin. The level of reduction can be quantified by spectrophotometers since resazurin exhibits an absorption peak at 600 ηm and resorufin at 570 ηm wavelengths. However, the requirement of a spectrophotometer and specific filters for the quantification could be a barrier to many laboratories. Digital cameras containing red, green and blue filters, which allow the capture of red (600 to 700 ηm and green (500 to 600 ηm light wavelengths in ranges bordering on resazurin and resorufin absorption bands, could be used as an alternative method for the assessment of resazurin and resorufin concentrations. Thus, our aim was to develop a simple, cheap and precise method based on a digital CCD camera to measure the reduction of resazurin. We compared the capability of the CCD-based method to distinguish different concentrations of L929 and normal Human buccal fibroblast cell lines with that of a conventional microplate reader. The correlation was analyzed through the Pearson coefficient. The results showed a strong association between the measurements of the method developed here and those made with the microplate reader (r² = 0.996; p < 0.01 and with the cellular concentrations (r² = 0.965; p < 0.01. We concluded that the developed Colorimetric Quantification System based on CCD Images allowed rapid assessment of the cultured cell concentrations with simple equipment at a reduced cost.