WorldWideScience

Sample records for simple laboratory-based radon

  1. Radon entry into a simple test structure

    DEFF Research Database (Denmark)

    Andersen, C.E.; Søgaard-Hansen, J.; Majborn, B.

    1992-01-01

    A simple test structure for studies of radon entry into houses has been constructed at a field site at Riso National Laboratory. It consists of a 40 1, stainless-steel cylinder placed in a 0.52 m deep quadratic excavation with a side length of 2.4 m. The excavation is lined with an airtight...... membrane, and soil gas enters the cylinder through a changeable interface in the bottom. The depressurisation of the cylinder is controlled by a mass-flow controller, thereby limiting the influence of natural driving forces. Pressures, temperatures and radon concentrations are measured continuously...... in the cylinder and in selected locations in the soil. In this paper, the test structure is described, and initial results concerning the transport of soil gas and radon under steady-state conditions are reported. It is found that the soil in the vicinity of the structure is partially depleted with respect...

  2. Tracing and quantifying groundwater inflow into lakes using a simple method for radon-222 analysis

    Directory of Open Access Journals (Sweden)

    T. Kluge

    2007-09-01

    Full Text Available Due to its high activities in groundwater, the radionuclide 222Rn is a sensitive natural tracer to detect and quantify groundwater inflow into lakes, provided the comparatively low activities in the lakes can be measured accurately. Here we present a simple method for radon measurements in the low-level range down to 3 Bq m−3, appropriate for groundwater-influenced lakes, together with a concept to derive inflow rates from the radon budget in lakes. The analytical method is based on a commercially available radon detector and combines the advantages of established procedures with regard to efficient sampling and sensitive analysis. Large volume (12 l water samples are taken in the field and analyzed in the laboratory by equilibration with a closed air loop and alpha spectrometry of radon in the gas phase. After successful laboratory tests, the method has been applied to a small dredging lake without surface in- or outflow in order to estimate the groundwater contribution to the hydrological budget. The inflow rate calculated from a 222Rn balance for the lake is around 530 m³ per day, which is comparable to the results of previous studies. In addition to the inflow rate, the vertical and horizontal radon distribution in the lake provides information on the spatial distribution of groundwater inflow to the lake. The simple measurement and sampling technique encourages further use of radon to examine groundwater-lake water interaction.

  3. Technique and equipment for measuring volume activity of radon in the air of radon laboratories and clinics

    International Nuclear Information System (INIS)

    Vorob'ev, I.B.; Krivokhatskij, A.S.; Nekrasov, E.V.; Nikolaev, V.A.; Potapov, V.G.; Terent'ev, M.V.

    1990-01-01

    Usability of a new equipment-technique combination for measuring radon activity in the air of radon laboratories and balneological clinics is studied. The complex includes nitrate-cellulose detector, radon chamber, Aist, Istra type spark counters and technique of spark counting. The method sensitivity is 50 Bqxm 3 , the error is 30%. Usability and advisability of track method in radon laboratories and balneological clinics for simultaneous measurement in several points of integral volumetric radon activities are confirmred. The method permits to carry out rapid and accurate bulk investigations. The results of determining mean volumetric radon activity in the air in different points of radon laboratory and radon clinics are presented

  4. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    International Nuclear Information System (INIS)

    Baumgartner, A.; Maringer, F.J.; Michai, P.; Kreuziger, M.

    2006-01-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  5. Result of the intercomparison exercise on radon measuring instruments and radon detectors 'bev- radon ring 2005'

    Energy Technology Data Exchange (ETDEWEB)

    Baumgartner, A. [Vienna Univ. of Technology, Atominstitut, Wien (Austria); Maringer, F.J.; Michai, P.; Kreuziger, M. [BEV-Federal Office of Metrology and Surveying, Wien (Austria)

    2006-07-01

    In spring 2005 the Federal Office of Metrology and Surveying (B.E.V.) invited all in Austria working radon measuring institutes to an intercomparison exercise at the radon calibration laboratory in the Arsenal. The aim of this intercomparison was on the one hand an objective inquiry and documentation of the current metrological potential on the section of radon measurement in Austria - both quantitative and qualitative- and on the other hand an initiative for the participating laboratories to optimize and improve their applied calibration-, measurement and analyse technique. Ten contacted Austrian radon laboratories were prepared to participate on the radon intercomparison exercise. The intercomparison exercise was carried out from 14. till 29. June at the radon calibration laboratory in the Arsenal of the B.E.V.. As radon emanation source a five stepped arranged, at the Arsenal built radon source was used. The source ( A.D.O.T.T.O. 1 is filled with a certified Ra- 226-standard solution of the Czech Metrological Institute (C.M.I.), Prag. A simple statistic based model was used for the evaluation and assessment of the results from the participants, which consider the statistic nature of the radioactive decay combined uncertainty. Altogether 183 measuring instruments participated the intercomparison exercise. Two reference measuring instruments, 22 active and 159 passive measuring instruments. The active measuring instruments formed 6 types of instruments and as passive radon detectors were 7 different types used from the participants. The positioning of the radon measuring instruments and detectors in the radon calibration laboratory was executed in regard to statistic points of view. From the active measuring instruments 17 could qualify and from the passive methods six from eight participants were in compliance to the given criteria. Radon measurements, which could have financial and economics relating implications (e.g. architectural redevelopment or

  6. Radon adsorbed in activated charcoal—a simple and safe radiation source for teaching practical radioactivity in schools and colleges

    Science.gov (United States)

    Al-Azmi, Darwish; Mustapha, Amidu O.; Karunakara, N.

    2012-07-01

    Simple procedures for teaching practical radioactivity are presented in a way that attracts students' attention and does not make them apprehensive about their safety. The radiation source is derived from the natural environment. It is based on the radioactivity of radon, a ubiquitous inert gas, and the adsorptive property of activated charcoal. Radon gas from ambient air in the laboratory was adsorbed into about 70 g of activated charcoal inside metallic canisters. Gamma radiation was subsequently emitted from the canisters, following the radioactive decay of radon and its progenies. The intensities of the emitted gamma-rays were measured at suitable intervals using a NaI gamma-ray detector. The counts obtained were analysed and used to demonstrate the radioactive decay law and determine the half-life of radon. In addition to learning the basic properties of radioactivity the students also get practical experience about the existence of natural sources of radiation in the environment.

  7. Radon adsorbed in activated charcoal- a simple and safe radiation source for teaching practical radioactivity in schools and colleges

    International Nuclear Information System (INIS)

    Al-Azmi, D.S.

    2014-01-01

    Simple procedures for teaching practical radioactivity are presented in a way that attracts students' attention and does not make them apprehensive about their safety. The radiation source is derived from the natural environment. It is based on the radioactivity of radon, an ubiquitous inert gas, and the adsorptive property of activated charcoal. Radon gas from ambient air in the laboratory was adsorbed into about 70 gram of activated charcoal inside metallic canisters. Gamma radiation was subsequently emitted from the canisters, following the radioactive decay of radon and its progenies. The intensities of the emitted gamma-rays were measured at suitable intervals using a NaI gamma-ray detector. The counts obtained were analysed and used to demonstrate the radioactive decay law and determine the half-life of radon. In addition to learning the basic properties of radioactivity, the students also get practical experience about the existence of natural sources of radiation in the environment. (author)

  8. Radon in dwellings and laboratories from central Mexico

    International Nuclear Information System (INIS)

    Segovia, N.; Pena, P.; Gaso, M.I.; Ponciano, G.

    2003-01-01

    Average indoor radon and airborne particles concentration levels have been measured in family houses, offices and laboratories within a survey protocol related to smoking health effects. The radon measurements were performed with Honeywell A9000A devices. Airborne particle fluctuations were determined using a Personal Data Logging Real Time Aerosol Monitor. The indoor radon average value obtained in the family houses was 40 Bq m -3 . However, short term peaks higher than 150 Bq m -3 were eventually observed. At the offices and laboratories indoor radon behaviour showed several values higher than the limits, particularly for those rooms having no external windows. Airborne PM10 average particulate matter indoors at a smoker house was 0.751 ± 0.420 mg m -3 in 24 h, reaching concentrations as high as 1.6 mg m -3 , one order of magnitude higher than the maximum permissible limit of outdoor PM10 (0.150 mg m -3 ) established by the Mexican legislation. (orig.)

  9. Radon in dwellings and laboratories from central Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Segovia, N.; Pena, P.; Gaso, M.I. [Inst. Nacional de Investigaciones Nucleares, Mexico D. F. (Mexico); Ponciano, G. [Facultad de Medicina, UNAM, Ciudad Univ., Mexico D.F. (Mexico)

    2003-07-01

    Average indoor radon and airborne particles concentration levels have been measured in family houses, offices and laboratories within a survey protocol related to smoking health effects. The radon measurements were performed with Honeywell A9000A devices. Airborne particle fluctuations were determined using a Personal Data Logging Real Time Aerosol Monitor. The indoor radon average value obtained in the family houses was 40 Bq m{sup -3}. However, short term peaks higher than 150 Bq m{sup -3} were eventually observed. At the offices and laboratories indoor radon behaviour showed several values higher than the limits, particularly for those rooms having no external windows. Airborne PM10 average particulate matter indoors at a smoker house was 0.751 {+-} 0.420 mg m{sup -3} in 24 h, reaching concentrations as high as 1.6 mg m{sup -3}, one order of magnitude higher than the maximum permissible limit of outdoor PM10 (0.150 mg m{sup -3}) established by the Mexican legislation. (orig.)

  10. Radon measurements during the building of a low-level laboratory

    CERN Document Server

    Antanasijevic, R; Bikit, I; Banjanac, R; Dragic, A; Joksimovic, D; Krmpotic, D; Udovicic, V; Vukovic, J

    1999-01-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m sup 2. The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm sup - sup 3 and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.

  11. Radon measurements during the building of a low-level laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Antanasijevic, R.; Anicin, I.; Bikit, I.; Banjanac, R.; Dragic, A.; Joksimovic, D.; Krmpotic, D.; Udovicic, V.; Vukovic, J

    1999-06-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m{sup 2}. The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm{sup -3} and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied.

  12. Radon measurements during the building of a low-level laboratory

    International Nuclear Information System (INIS)

    Antanasijevic, R.; Anicin, I.; Bikit, I.; Banjanac, R.; Dragic, A.; Joksimovic, D.; Krmpotic, D.; Udovicic, V.; Vukovic, J.

    1999-01-01

    Radon measurements were provided during the different stages of building of a low-level laboratory in Belgrade. The depth of the laboratory is 12 m, equivalent to 30 m of water with an area of 45 m 2 . The whole of the laboratory is hermetically lined with 1 mm A1 foil and is ventilated with filtered air. Radon concentrations were measured with the CR-39 detector as well as via the gamma-ray spectroscopic measurements. The radon concentrations in the air were achieved to 20 Bqm -3 and reduction of secondary and tertiary cosmic-ray fluxes is five times when ventilation, filtering and sealing was applied

  13. Radon-film-badges by solid radiators to complement track detector-based radon monitors

    International Nuclear Information System (INIS)

    Tommasino, L.; Tommasino, M.C.; Viola, P.

    2009-01-01

    Existing passive radon monitors, based on track detectors, present many shortcomings, such as a limited response sensitivity for one-week-indoor measurements and a limited response linearity for the assessment of large radon exposures indoors, in thermal spa, in caves, and in soil. Moreover, for in-soil measurements these monitors are too bulky and are often conducive to wrong results. For what concerns the radon-in-water measurements, they are just not suitable. A new generation of passive radon monitors is introduced in this paper, which are very similar to the compact badges used in neutron- and gamma-dosimetry and will be referred to as radon-film-badges. These film-badges are formed by thin-film radiators with suitable radon-sorption characteristics, facing track detectors. The key strategy adopted for these radiators is to exploit an equilibrium type of radon sorption in solids. Even though this new generation of passive monitors is at its infancy, it appears already clear that said monitors make it finally possible to overcome most of the shortcomings of existing passive radon monitors. These devices are uniquely simple and can be easily acquired by any existing radon service to complement their presently used passive radon monitors with little or no effort.

  14. Fluid-based radon mitigation technology development for industrial applications

    International Nuclear Information System (INIS)

    Liu, K.V.; Gabor, J.D.; Holtz, R.E.; Gross, K.C.

    1996-01-01

    The objective of the radon mitigation technology development effort is to develop an efficient and economical radon gas removal technology based on a fluid absorption process. The technology must be capable of cleaning up a wide range of radon gas stream concentrations to a level that meets EPA gas emission standards for residential and industrial applications. Argonne has recently identified a phenomenon that offers the possibility of radon recovery from the atmosphere with high efficiency at room temperature, and radon release at slightly elevated temperatures (50-60 degrees C.) such a device would offer numerous substantial advantages over conventional cryogenic charcoal systems for the removal of radon. Controlled sources of radon in Argonne's radon research facility are being used to quantitatively assess the performance of a selected class of absorbing fluids over a range of radon concentrations. This paper will discuss the design of laboratory- and engineering-scale radon absorption units and present some preliminary experimental test results

  15. Simple tecniques of radiation protection for radon monitoring in air and water

    International Nuclear Information System (INIS)

    Napolitano, C.M.; Oliveira Sampa, M.H. de; Palacios, E.

    1978-01-01

    Simple techniques for 'in situ' radon concentration measurements in air and water using a scintillation chamber are discussed. The chamber was constructed with a comercial 'Pyrex' erlenmeyer flask by uniformely coating with powdered ZnS:Ag all the flask's internal surface, except its base. For air monitoring, the sample is introduced into the scintillation chamber and when the radioactive equilibrium between radon and its daughters of short half life is reached, the chamber is placed into a light-tight box that has a photomultiplier connected to a counting system. For water monitoring, the sample is placed in a plastic bottle and the bottle connected with a scintillation chamber for 5 hours. Afterwards, the gas of the chamber is counted and radon concentration in water is determined through the counting rate observed in the gaseous phase. The detection limits of these techniques in air and water monitoring were 7pCi/l and 1,5pCi/l [pt

  16. Measurement of radon emanation of drainage layer media by liquid scintillation counting

    International Nuclear Information System (INIS)

    Turtiainen, T.

    2009-01-01

    Slab-on-ground is a typical base floor construction type in Finland. The drainage layer between the slab and soil is a layer of sand, gravel or crushed stone. This layer has a minimum thickness of 200 mm and is sometimes even 600 mm thick, and thus may be a significant contributor to indoor air radon. In order to investigate radon emanation from the drainage layer material, a simple laboratory test was developed. Many organic solvents have high Ostwald coefficients for radon, i.e., the ratio of the volume of gas absorbed to the volume of the absorbing liquid, which enables direct absorption of radon into a liquid scintillation cocktail. Here, we first present equations relating to the processes of gas transfer in emanation measurement by direct absorption into liquid scintillation cocktails. In order to optimize the method for emanation measurement, four liquid scintillation cocktails were assessed for their ability to absorb radon from air. A simple apparatus consisting of a closed glass container holding an open liquid scintillation vial was designed and the diffusion/absorption rate and Ostwald coefficient were determined for a selected cocktail. Finally, a simple test was developed based on this work. (author)

  17. Radon and environmental radioactivity in the Canfranc Underground Laboratory

    International Nuclear Information System (INIS)

    Bandac, I.; Bettini, A.; Borjabad, S.; Nunez-Lagos, R.; Perez, C.; Rodriguez, S.; Sanchez, P.; Villar, J. A.

    2014-01-01

    The results of more than one year of measurements of Radon and environmental radioactivity in the Canfranc Underground Laboratory (LSC) are presented. Radon and atmospheric parameters have registered by an Alpha guard P30 equipment and the environmental radioactivity has been measured by means of UD-802A Panasonic thermoluminescent dosimeters (TLD) processed by an UD716 Panasonic unit. Series of results along with their possible correlations are presented. Both the Radon level and the ambient dose equivalent H (10) are much lower than the allowed ones so no radiological risk exists to persons working in the LSC. Also its excellent environmental radiological quality has been confirmed. (Author)

  18. Radon transport in fractured soil. Laboratory experiments and modelling

    International Nuclear Information System (INIS)

    Hoff, A.

    1997-10-01

    Radon (Rn-222) transport in fractured soil has been investigated by laboratory experiments and by modelling. Radon transport experiments have been performed with two sand columns (homogeneous and inhomogeneous) and one undisturbed clayey till column containing a net of preferential flow paths (root holes). A numerical model (the finite-element model FRACTRAN) and an analytic model (a pinhole model) have been applied in simulations if soil gas and radon transport in fractured soil. Experiments and model calculations are included in a discussion of radon entry rates into houses placed on fractured soil. The main conclusion is, that fractures does not in general alter transport of internally generated radon out of soil, when the pressure and flow conditions in the soil is comparable to the conditions prevailing under a house. This indicates the important result, that fractures in soil have no impact on radon entry into a house beyond that of an increased gas permeability, but a more thorough investigation of this subject is needed. Only in the case where the soil is exposed to large pressure gradients, relative to gradients induced by a house, may it be possible to observe effects of radon exchange between fractures and matrix. (au) 52 tabs., 60 ill., 5 refs

  19. Radon transport in fractured soil. Laboratory experiments and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Hoff, A

    1997-10-01

    Radon (Rn-222) transport in fractured soil has been investigated by laboratory experiments and by modelling. Radon transport experiments have been performed with two sand columns (homogeneous and inhomogeneous) and one undisturbed clayey till column containing a net of preferential flow paths (root holes). A numerical model (the finite-element model FRACTRAN) and an analytic model (a pinhole model) have been applied in simulations if soil gas and radon transport in fractured soil. Experiments and model calculations are included in a discussion of radon entry rates into houses placed on fractured soil. The main conclusion is, that fractures does not in general alter transport of internally generated radon out of soil, when the pressure and flow conditions in the soil is comparable to the conditions prevailing under a house. This indicates the important result, that fractures in soil have no impact on radon entry into a house beyond that of an increased gas permeability, but a more thorough investigation of this subject is needed. Only in the case where the soil is exposed to large pressure gradients, relative to gradients induced by a house, may it be possible to observe effects of radon exchange between fractures and matrix. (au) 52 tabs., 60 ill., 5 refs.

  20. Comparison of field-measured radon diffusion coefficients with laboratory-measured coefficients

    International Nuclear Information System (INIS)

    Lepel, E.A.; Silker, W.B.; Thomas, V.W.; Kalkwarf, D.R.

    1983-04-01

    Experiments were conducted to compare radon diffusion coefficients determined for 0.1-m depths of soils by a steady-state method in the laboratory and diffusion coefficients evaluated from radon fluxes through several-fold greater depths of the same soils covering uranium-mill tailings. The coefficients referred to diffusion in the total pore volume of the soils and are equivalent to values for the quantity, D/P, in the Generic Environmental Impact Statement on Uranium Milling prepared by the US Nuclear Regulatory Commission. Two soils were tested: a well-graded sand and an inorganic clay of low plasticity. For the flux evaluations, radon was collected by adsorption on charcoal following passive diffusion from the soil surface and also from air recirculating through an aluminum tent over the soil surface. An analysis of variance in the flux evaluations showed no significant difference between these two collection methods. Radon diffusion coefficients evaluated from field data were statistically indistinguishable, at the 95% confidence level, from those measured in the laboratory; however, the low precision of the field data prevented a sensitive validation of the laboratory measurements. From the field data, the coefficients were calculated to be 0.03 +- 0.03 cm 2 /s for the sand cover and 0.0036 +- 0.0004 cm 2 /s for the clay cover. The low precision in the coefficients evaluated from field data was attributed to high variation in radon flux with time and surface location at the field site

  1. Quality assurance for radon exposure chambers at the National Air and Radiation Environmental Laboratory, Montgomery, Alabama

    Energy Technology Data Exchange (ETDEWEB)

    Semler, M.O.; Sensintaffar, E.L. [National Air and Radiation Environmental Laboratory, Montgomery, AL (United States)

    1993-12-31

    The Office of Radiation and Indoor Air, U.S. Environmental Protection Agency (EPA), operates six radon exposure chambers in its two laboratories, the National Air and Radiation Environmental Laboratory (NAREL) in Montgomery, Alabama, and the Las Vegas Facility, Las Vegas, Nevada. These radon exposure chambers are used to calibrate and test portable radon measuring instruments, test commercial suppliers of radon measurement services through the Radon Measurement Proficiency Program, and expose passive measurement devices to known radon concentrations as part of a quality assurance plan for federal and state studies measuring indoor radon concentrations. Both laboratories participate in national and international intercomparisons for the measurement of radon and are presently working with the National Institute of Standards and Technology (NIST) to receive a certificate of traceability for radon measurements. NAREL has developed an estimate of the total error in its calibration of each chamber`s continuous monitors as part of an internal quality assurance program. This paper discusses the continuous monitors and their calibration for the three chambers located in Montgomery, Alabama, as well as the results of the authors intercomparisons and total error analysis.

  2. Optimization of radiation safety conditions in radon laboratories

    International Nuclear Information System (INIS)

    Kibal'nik, S.P.; Koroleva, T.M.

    1990-01-01

    The study was aimed at studying working conditions of personnel, engaged in production and supply of radon solution in medical and prophylactic institutions of the Kaliningrad region for the period 1962-1988. Data on examinations carried out at radon laboratories during this period by radiological group of the Kaliningrad sanitary epidemiological station were used as a basis for the study. Positive dynamics of indicators of radiation safety of the persons working at these objects is indicated, concrete measures and ways for improving working conditions of the personnel and role of sanitary epidemiological service in solving these problems are shown. 2 refs.; 1 tab

  3. Radon monitoring using long-range alpha detector-based technology

    International Nuclear Information System (INIS)

    Bolton, R.D.

    1994-01-01

    Long-Range Alpha Detector (LRAD) technology is being studied for monitoring radon gas concentrations. LRAD-based instruments collect and measure the ionization produced in air by alpha decays. These ions can be moved to a collection grid via electrostatic ion-transport design collected approximately 95% of the radon produced ions, while instruments using an airflow transport design collected from 44% to 77% of these ions, depending on detector geometry. The current produced by collecting this ionization is linear with respect to 222 Rn concentration over the available test range of 0.07 to 820 pCi/L. In the absence of statistical limitations due to low radon concentrations, the speed of response of LRAD-based instruments is determined by the air exchange rate, and therefore changes in radon concentration can be detected in just a few seconds. Recent tests show that at radon concentrations below 20 pCi/L current pulses produced by individual alpha decays can be counted, thus improving detector sensitivity and stability even further. Because these detectors are simple, rugged, and do not consume much power, they are natural candidates for portable, battery operation

  4. Radon-technical design methods based on radon classification of the soil

    International Nuclear Information System (INIS)

    Kettunen, A.V.

    1993-01-01

    Radon-technical classification of the foundation soil divides the foundation soil into four classes: negligible, normal, high and very high. Separate radon-technical designing methods and radon-technical solutions have been developed for each class. On regions of negligible class, no specific radon-technical designing methods are needed. On regions of normal radon class, there is no need for actual radon-technical designing based on calculations, whereas existing radon-technical solutions can be used. On regions of high and very high radon class, a separate radon-technical designing should be performed in each case, where radon-technical solutions are designed so that expected value for indoor radon content is lower than the maximum allowable radon content. (orig.). (3 refs., 2 figs., 2 tabs.)

  5. A simple bubbling system for measuring radon (222Rn) gas concentrations in water samples based on the high solubility of radon in olive oil.

    Science.gov (United States)

    Al-Azmi, D; Snopek, B; Sayed, A M; Domanski, T

    2004-01-01

    Based on the different levels of solubility of radon gas in organic solvents and water, a bubbling system has been developed to transfer radon gas, dissolving naturally in water samples, to an organic solvent, i.e. olive oil, which is known to be a good solvent of radon gas. The system features the application of a fixed volume of bubbling air by introducing a fixed volume of water into a flask mounted above the system, to displace an identical volume of air from an air cylinder. Thus a gravitational flow of water is provided without the need for pumping. Then, the flushing air (radon-enriched air) is directed through a vial containing olive oil, to achieve deposition of the radon gas by another bubbling process. Following this, the vial (containing olive oil) is measured by direct use of gamma ray spectrometry, without the need of any chemical or physical processing of the samples. Using a standard solution of 226Ra/222Rn, a lowest measurable concentration (LMC) of radon in water samples of 9.4 Bq L(-1) has been achieved (below the maximum contaminant level of 11 Bq L(-1)).

  6. Diurnal Variations of Equilibrium Factor and Unattached fraction of Radon Progeny in Some Houses and Laboratories

    International Nuclear Information System (INIS)

    Lee, Seung Chan; Kang, Hee Dong; Kim, Chang Kyu; Lee, Dong Myung

    2001-01-01

    The variation characteristics of radon concentration, equilibrium equivalent concentration and equilibrium factor in some house and laboratory buildings have been studied. The variation of equilibrium factor and the unattached fraction of radon progeny with ventilation condition have been also estimated. The averages of radon concentration, equilibrium equivalent concentration and equilibrium factor were 30 Bq m -3 , 19.6 Bq m -3 and 0.65 in seven houses, while 55.0 Bq m -3 , 31.9 Bq m -3 and 0.58 in three laboratory buildings, respectively. The diurnal variation of radon concentration, equilibrium equivalent concentration and equilibrium factor in indoor showed a typical pattern that the radon concentration, equilibrium equivalent concentration and equilibrium factor increased at dawn and morning, while decreased at midday and evening. While the equilibrium factor rate deceased in the indoor environment which was well ventilated, the unattached fraction of radon progeny increased. The equilibrium factor was in proportion to air pressure and humidity of indoor, whereas in inverse proportion to temperature

  7. Measurement of the concentration of radon in the air

    International Nuclear Information System (INIS)

    Aten, J.B.Th.; Bierhuizen, H.W.J.; Hoek, L.P. van; Ros, D.; Weber, J.

    1975-01-01

    A simple transportable air monitoring apparatus was developed for controlling the radon contamination of air in laboratory rooms. It is not highly accurate but is sufficient to register the order of magnitude of the radon concentration. Air is pumped through a filter for one or two hours and an alpha decay curve of the dust on the filter is determined. Scintillation counting forty minutes after sampling indicates the radon activity. The calibration method of measuring the equilibrium of daughter product concentrations is discussed extensively

  8. Laboratory measurements of the influence of air treatment devices on radon daughters

    International Nuclear Information System (INIS)

    Rajala, M.; Janka, K.; Graeffe, G.; Kulmala, V.; Lehtimaeki, M.

    1984-01-01

    This paper presents laboratory measurements in which the effect of air cleaners on radon decay products has been studied. Experiments show that both a high-efficiency particulate air filter and an electrostatic precipitator substantially decrease the total airborne radon daughter concentration leading to a situation where most of the decay products are unattached. However, in some situations the concentration of fine particles generated by the corona discharge in the electronic air cleaner becomes high enough to increase the total radon daughter concentration and decrease the free decay product concentration. Impurities in the air may have a notable role in the formation of these condensation nuclei. (Author)

  9. The design of a simple radon-detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Du Genyuan; Qiu Yingyu; Zhang Jiang

    2007-01-01

    Introduction are given on the internal composition of the radon-detecting instrument based on MCU and the working of the real electric circuit. The single-chip microcomputer P89C58 of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  10. The design of a simple radon-detecting instrument based on MCU

    International Nuclear Information System (INIS)

    Du Genyuan; Chen Jianjun; Zhang Jiang

    2008-01-01

    Introduction are given on the internal composition of the radon-detecting instrument based on MCU and the working of the real electric circuit. The single-chip microcomputer P89C58 of PHILIPS is adopted as the micro-controller of the instrument, realizing such functions as counting input pulses within fixed time, data processing, liquid crystal display, keyboard interface, serial communication, etc. The instrument turns out to be low in work consumption, with relatively high degree of concentration and computerization, and is recommended for field operations. (authors)

  11. Long term indoor radon measurements in the pelletron laboratory at the UNAM physics institute

    OpenAIRE

    Espinosa, G.; Golzarri, J.I.; Lopez, K.; Rickards, J.

    2011-01-01

    The results of six months of continuous measurement of the indoor radon concentration levels in the building where the Instituto de Física 3 MV Pelletron particle accelerator is located are presented. This study has three major objectives: (a) to know the actual values of the levels of indoor radon in this installation, where personnel spend many hours and sometimes days; (b) assess the radiological risk from radon inhalation for personnel working permanently in the laboratory, as well as inc...

  12. Quantitative evaluation of the lung cancer deaths attributable to residential radon: A simple method and results for all the 21 Italian Regions

    International Nuclear Information System (INIS)

    Bochicchio, F.; Antignani, S.; Venoso, G.; Forastiere, F.

    2013-01-01

    Pooled analyses of epidemiological case-control studies on lung cancer and residential radon have shown that radon exposure in dwellings increases lung cancer risk, and that the increase is statistically significant also for prolonged exposures to low-medium level of radon concentration, i.e. levels commonly found in many dwellings. In this paper, a simple method to evaluate the health burden due to the presence of radon in homes (i.e. the number of lung cancer deaths attributable to radon exposure in dwellings) was presented. This method is based on the following parameters: i) the excess relative risk per unit of exposure evaluated in case-control studies; ii) the average radon concentration that can be considered representative of population exposure in dwellings; iii) the total number of lung cancer deaths occurring each year. Moreover, the interaction between radon and cigarette smoking is needed to be taken into account: in fact, although most of the persons are non-smokers, most of the lung cancer deaths attributed to radon are actually due to the multiplicative effect of radon and cigarette smoking. To show this effect, the number of radon related lung cancer deaths estimated to occur among current, former and never smokers was calculated separately for males and females, taking into account the relative risk of lung cancer for the different smoking categories and the prevalence of smoking habits. The methodology described in this work was applied to all the 21 Italian Regions in order to illustrate it. The overall fraction of lung cancer deaths attributable to radon in Italy is about 10%, with values in individual Regions ranging from 4% to 16%. The greater part of the lung cancers attributable to radon is estimated to occur among current smokers for both males and females (72% and 60%, respectively, at national level). This is due to the synergistic effects of radon and cigarette smoking, which should therefore be taken into account in policies aimed to

  13. Long term indoor radon measurements in the pelletron laboratory at the UNAM physics institute

    International Nuclear Information System (INIS)

    Espinosa, G.; Golzarri, J. I.; Lopez, K.; Rickards, J.

    2011-01-01

    The results of six months of continuous measurement of the indoor radon concentration levels in the building where the Physics Institute 3 MV Pelletron particle accelerator is located are presented. This study has three major objectives: a) to know the actual values of the levels of indoor radon in this installation, where personnel spend many hours and sometimes days; b) assess the radiological risk from radon inhalation for personnel working permanently in the laboratory, as well as incidental users; and c) establish, if necessary, time limits for continuous permanence on the location for indoor radon exposure. Passive nuclear track detectors and dynamic systems were employed, covering six months (August, 2009 to January, 2010). For the calculation of internal dose the Radon Individual Dose Calculator was used. The results indicate that the indoor radon levels are below the US EPA recommended levels (400 Bq/m 3 ) in workplaces. The measurements help to establish levels for workplaces in Mexico. (Author)

  14. Laboratory measurements of radon diffusion through multilayered cover systems for uranium tailings

    International Nuclear Information System (INIS)

    Nielson, K.K.; Rogers, V.C.; Rich, D.C.; Nederhand, F.A.; Sandquist, G.M.; Jensen, C.M.

    1981-12-01

    Laboratory measurements of radon fluxes and radon concentration profiles were conducted to characterize the effectiveness of multilayer cover systems for uranium tailings. The cover systems utilized soil and clay materials from proposed disposal sites for the Vitro, Durango, Shiprock, Grand Junction and Riverton tailings piles. Measured radon fluxes were in reasonable agreement with values predicted by multilayer diffusion theory. Results obtained by using air-filled porosities in the diffusion calculations were similar to those obtained by using total porosities. Measured diffusion coefficients were a better basis for predicting radon fluxes than were correlations of diffusion coefficient with moisture or with air porosity. Radon concentration profiles were also fitted by equations for multilayer diffusion in the air-filled space. Layer-order effects in the multilayer cover systems were examined and estimated to amount to 10 to 20 percent for the systems tested. Quality control measurements in support of the multilayer diffusion tests indicated that moisture absorption was not a significant problem in radon flux sampling with charcoal canisters, but that the geometry of the sampler was critical. The geometric design of flux-can samplers was also shown to be important. Enhanced radon diffusion along the walls of the test columns was examined and was found to be insignificant except when the columns had been physically disturbed. Additional moisture injected into two test columns decreased the radon flux, as expected, but appeared to migrate into surrounding materials or to be lost by evaporation. Control of moisture content and compaction in the test columns appeared to be the critical item affecting the accuracies of the experiments

  15. A Laboratory for studying radon mitigation methods in high-rise office buildings in Hong Kong

    International Nuclear Information System (INIS)

    Leung, J.K.C.; Hung, L.C.; Tso, M.Y.W.

    1996-01-01

    A territory-wide survey of indoor radon level in 1993 showed that 17% of offices Hong Kong have radon concentrations above 200 Bq m -3 compared with 4% for dwellings. Consequently, the Radioisotope Unit Radon Analysis Laboratory (RURAL) is being built for studying radon mitigation methods applicable to high-rise office buildings. The laboratory consists of three rooms; the main exposure room is built of concrete and is surrounded by the buffer room; and all controls and operations are done inside the control room. The exposure room can, with the aid of the buffer room, simulate any environmental conditions that can be faced by a real building. The pressure, temperature and humidity can be adjusted to any meteorological conditions that can be found in Hong Kong. Pressure differential and temperature differential can be adjusted to simulate the arrival of fronts, troughs or typhoons. Aerosol concentration and distribution inside the exposure room are controllable as well as the ventilation conditions. Various mitigation methods will be tested under different conditions. Passive methods include application of radon barriers to building structures and active methods include the use of air cleaners; techniques to increase radon daughters plateout or reduce their attachment to aerosols; and various modifications to the ventilation systems. Mitigation techniques involving modifications to the building strictures and building services will also be developed with the help of the RURAL. (author)

  16. Soil gas and radon entry into a simple test structure: Comparison of experimental and modelling results

    DEFF Research Database (Denmark)

    Andersen, C.E.; Søgaard-Hansen, J.; Majborn, B.

    1994-01-01

    A radon test structure has been established at a field site at Riso National Laboratory. Measurements have been made of soil gas entry rates, pressure couplings and radon depletion. The experimental results have been compared with results obtained from measured soil parameters and a two......-dimensional steady-state numerical model of Darcy flow and combined diffusive and advective transport of radon. For most probe locations, the calculated values of the pressure couplings and the radon depletion agree well with the measured values, thus verifying important elements of the Darcy flow approximation......, and the ability of the model to treat combined diffusive and advective transport of radon. However, the model gives an underestimation of the soil gas entry rate. Even if it is assumed that the soil has a permeability equal to the highest of the measured values, the model underestimates the soil gas entry rate...

  17. Characteristics of radon concentration distributions measurement with two-filter method in the storage rooms of Ra-Be neutron source and the adjacent laboratories

    International Nuclear Information System (INIS)

    Liu Shuhuan; Chu Jun; Zhao Yaolin; Bao Lihong; Chen Wei; Wu Yuelei

    2012-01-01

    The basic principle of radon measurement with two-filter method is introduced in this paper. The levels of radon concentration in the storage rooms and the adjacent laboratories are measured and compared with the type of FT-648 radon measurement instrument. The measurement results showed that the levels of radon concentration in Ra-Be neutron source storage rooms are not higher than those in the adjacent laboratories, then it can be deduced that no radon gas was leaked out form the shielded and sealed Ra-Be neutron sources. The radon concentrations measured in the laboratories were near to the average level compared to the statistical results of the indoor dwellings' radon concentrations in Xi'an. The values didn't exceed the national standard limits(200 Bq·m -3 ). Furthermore, it is found that the radon concentration value measured at rainy or cloudy day is lesser than that at sunny day, and good ventilation conditions can effectively decrease the indoor radon concentration level. Meanwhile, the mechanisms of the radon concentration distributions in the laboratories influenced by the factors including various weather conditions (rainy, sunny and cloudy), ventilation and different measurement time periods in a day, etc. are primarily analyzed. The measurement results in this work provide some relative reference data for prediction the situations of Ra-Be neutron sources safety storage and experimenters' radiation protection in the laboratories. (authors)

  18. Radon in Antarctica

    International Nuclear Information System (INIS)

    Ilic, R.; Rusov, V.D.; Pavlovych, V.N.; Vaschenko, V.M.; Hanzic, L.; Bondarchuk, Y.A.

    2005-01-01

    The paper reviews results of radon measurements obtained in Antarctic research stations in the last 40 years by both active and passive radon monitors. A brief description of the radon laboratory set-up in the Ukrainian Academician Vernadsky station on the Antarctic Peninsula (W 64 o 16 ' , S 65 o 15 ' ), where radon is measured by two types of etched track Rn dosimeter and 4 types of continuous radon monitoring devices is presented. Some selected results of research work are described related to: (i) analysis of radon storms, defined as an abrupt increase of 222 Rn during the occurrence of a cyclone, and its applicability for the study of the transport of air masses of continental origin to Antarctica; (ii) a study of the correlation of changes of radon concentration and geomagnetic field induced by tectonic activity and its application to predicting tectonomagnetic anomalies, and (iii) verification of a newly developed theoretical model based on noise analysis of the measured radon signal for earthquake prediction. Suggestions for future utilization of radon for basic research in Antarctica (and not only in Antarctica) conclude the contribution. conclude the contribution

  19. Radon Adsorbed in Activated Charcoal--A Simple and Safe Radiation Source for Teaching Practical Radioactivity in Schools and Colleges

    Science.gov (United States)

    Al-Azmi, Darwish; Mustapha, Amidu O.; Karunakara, N.

    2012-01-01

    Simple procedures for teaching practical radioactivity are presented in a way that attracts students' attention and does not make them apprehensive about their safety. The radiation source is derived from the natural environment. It is based on the radioactivity of radon, a ubiquitous inert gas, and the adsorptive property of activated charcoal.…

  20. EML indoor radon workshop, 1982

    International Nuclear Information System (INIS)

    George, A.C.; Lowder, W.; Fisenne, I.; Knutson, E.O.; Hinchliffe, L.

    1983-07-01

    A workshop on indoor radon, held at the Environmental Measurements Laboratory (EML) on November 30 and December 1, 1982, covered recent developments in radon daughter research and development. Thirty papers were presented dealing with standardization and quality assurance measurement methods, surveys, measurements strategy, physical mechanisms of radon and radon daughter transport and development of guidance standards for indoor exposures. The workshop concluded with a planning session that identified the following needs: (1) national and international intercomparisons of techniques for measuring radon and radon daughter concentrations, working level and radon exhalation flux density; (2) development and refinement of practical measurement techniques for thoron and its daughter products; (3) quantitative definition of the sources of indoor radon and the mechanisms of transport into structures; (4) better knowledge of the physical properties of radon daughters; (5) more complete and accurate data on the population exposure to radon, which can only be met by broadly based surveys; and (6) more international cooperation and information exchange among countries with major research programs

  1. Overview of current radon and radon daughter research at LBL

    International Nuclear Information System (INIS)

    1983-01-01

    This report provides a brief summary of radon and radon daughter research at Lawrence Berkeley Laboratory. The radon and radon daughter research program has two broad goals: (1) the study of sources of radon and its subsequent transport into houses, and (2) research on the behavior of radon daughters in indoor environments. Additional research effort is directed to several auxiliary areas, including development of instrumentation and monitoring techniques, studies of indoor air movement, and measurement and control of indoor particulate concentrations

  2. Radon classification of building ground

    International Nuclear Information System (INIS)

    Slunga, E.

    1988-01-01

    The Laboratories of Building Technology and Soil Mechanics and Foundation Engineering at the Helsinki University of Technology in cooperation with The Ministry of the Environment have proposed a radon classification for building ground. The proposed classification is based on the radon concentration in soil pores and on the permeability of the foundation soil. The classification includes four radon classes: negligible, normal, high and very high. Depending on the radon class the radon-technical solution for structures is chosen. It is proposed that the classification be done in general terms in connection with the site investigations for the planning of land use and in more detail in connection with the site investigations for an individual house. (author)

  3. Managing Radon in Schools

    Science.gov (United States)

    EPA recommends testing all schools for radon. As part of an effective IAQ management program, schools can take simple steps to test for radon and reduce risks to occupants if high radon levels are found.

  4. The effect of filtration on radon daughter atmospheres: Laboratory and field experiments

    International Nuclear Information System (INIS)

    Jonassen, N.; Jensen, B.

    1987-01-01

    Airborne radon daughters may be removed from the air by internal filtration using mechanical or electrofilters. The effect of the filtration may be evaluated in absolute measure by the decrease in the potential alpha energy concentration (or equivalent equilibrium concentration) or relatively by the decrease in the equilibrium factor. The filtration, however, may also change the distribution of airborne radon daughter activity between the unattached and the aerosol-attached state in a way to increase the radiological dose corresponding to a given potential alpha energy concentration. The paper describes a series of laboratory and field experiments which indicate that it is possible by the use of household electrofilters with filtration rates of 2-3 h -1 to lower the radon daughter concentrations to about 20 -30 % and the average radiological dose to about 50-60 % of the value in unfiltered air

  5. Ground-truthing predicted indoor radon concentrations by using soil-gas radon measurements

    International Nuclear Information System (INIS)

    Reimer, G.M.

    2001-01-01

    Predicting indoor radon potential has gained in importance even as the national radon programs began to wane. A cooperative study to produce radon potential maps was conducted by the Environmental Protection Agency (EPA), U.S. Geological Survey (USGS), Department of Energy (DOE), and Lawrence Berkeley Laboratory (LBL) with the latter taking the lead role. A county-wide predictive model based dominantly on the National Uranium Resource Evaluation (NURE) aerorad data and secondly on geology, both small-scale data bases was developed. However, that model breaks down in counties of complex geology and does not provide a means to evaluate the potential of an individual home or building site. Soil-gas radon measurements on a large scale are currently shown to provide information for estimating radon potential at individual sites sort out the complex geology so that the small-scale prediction index can be validated. An example from Frederick County, Maryland indicates a positive correlation between indoor measurements and soil-gas data. The method does not rely on a single measurement, but a series that incorporate seasonal and meteorological considerations. (author)

  6. The Reference Laboratory for Radon Gas Activity Concentration Measurements at PSI; Das Referenzlabor fuer Radongas-Konzentrationsmessungen am PSI

    Energy Technology Data Exchange (ETDEWEB)

    Schuler, Christoph

    1998-09-01

    Active or passive radon gas measuring instruments are exposed during intercomparison exercises in the radon chamber of the Reference Laboratory for Radon Gas Concentration Measurements at Paul Scherrer Institut: The traceability of radon gas measurements to nationally and internationally acknowledged standards is inspected in the reference atmosphere of the chamber with calibrated {sup 222}Rn activity concentration. The use of secondary standards guarantees the traceability of the radon chamber reference atmosphere. Besides the principal secondary standard, a radon gas standard (secondary standard I), a {sup 226}Ra standard solution (secondary standard II) and a {sup 222}Rn emanation standard (secondary standard III) are used. The {sup 222}Rn activity delivered by one of these standards is quantitatively transferred into a reference volume and hence converted to an activity concentration serving for the calibration of a measuring instrument transfer standard consisting of scintillation cell and counter. By this way, the transfer standard calibration is related and traceable to the internationally acknowledged primary standard laboratories National Institute of Standards and Technology, Gaithersburg, Maryland (U.S.A.) or National Physical Laboratory, Teddington, Middlesex (UK). The calibrated transfer standard is then used to calibrate the radon gas activity concentration in the radon chamber. For a single grab sampling determination of the {sup 222}Rn activity concentration in the radon chamber with the transfer standard, the estimation of Type A and Type B uncertainties yields a relative expanded uncertainty (95% confidence level) of minimum 3% for high concentration levels (10 kBqm{sup -3}) and maximum 30% for low concentration levels (0.2 kBqm{sup -3}). Extended evaluations of the reproducibility of calibration factor measurements obtained by calibration of the transfer standard with the secondary standards I, II and III show a very good reproducibility quality

  7. Measurement of unattached radon progeny based in electrostatic deposition method

    International Nuclear Information System (INIS)

    Canoba, A.C.; Lopez, F.O.

    1999-01-01

    A method for the measurement of unattached radon progeny based on its electrostatic deposition onto wire screens, using only one pump, has been implemented and calibrated. The importance of being able of making use of this method is related with the special radiological significance that has the unattached fraction of the short-lived radon progeny. Because of this, the assessment of exposure could be directly related to dose with far greater accuracy than before. The advantages of this method are its simplicity, even with the tools needed for the sample collection, as well as the measurement instruments used. Also, the suitability of this method is enhanced by the fact that it can effectively be used with a simple measuring procedure such as the Kusnetz method. (author)

  8. The use of soil gas as radon source in radon chambers

    International Nuclear Information System (INIS)

    Al-Azmi, Darwish

    2009-01-01

    A procedure is described in which soil gas is utilized as an alternative to the 226 Ra source for the supply of the radon gas required to fill a radon chamber where radon-measuring devices are calibrated. The procedure offers opportunities to vary the radon concentration within the chamber around an average value of about 500 Bq/m 3 , which is considered to be sufficient for calibrating indoor radon detectors. The procedure is simple and the radon source does not require radiation protection certification (for import and/or use), unlike the commercially produced standard radioactive ( 226 Ra) sources.

  9. Environmental Assessment for moving the Pacific Northwest Laboratory radon generators from Life Sciences Laboratory II, Richland North Area, to Life Sciences Laboratory I, 300 Area, and their continued use in physical and biological research

    International Nuclear Information System (INIS)

    Nelson, I.C.

    1993-01-01

    The Pacific Northwest Laboratory (PNL) radon generators are a core resource of the overall U. S. Department of Energy's (DOE) Radon Research Program and are administratively controlled within the ''Radon Hazards in Homes'' project. This project primarily focuses on radon exposures of animals and addresses the major biologic effects and factors influencing risks of indoor radon exposures. For example, the ''Mechanisms of Radon Injury'' and ''In vivo/In vitro Radon-Induced Cellular Damage'' projects specifically address the cytogenetic and DNA damage produced by radon exposure as part of a larger effort to understand radon carcinogenesis. Several other ongoing PNL projects, namely: ''Biological Effectiveness of Radon Alpha Particles: A Microbeam Study of Dose Rate Effects,'' ''Laser Measurements of Pb-210,'' ''Radon Transport Modeling in Soils,'' ''Oncogenes in Radiation Carcinogenesis,'' ''Mutation of DNA Targets,'' ''Dosimetry of Radon Progeny,'' and ''Aerosol Technology Development'' also use the radon exposure facilities in the conduct of their work. While most, but not all, studies in the PNL Radon Research Program are funded through DOE's Office of Health and Environmental Research, PNL also has ongoing collaborative radon studies with investigators worldwide; many of these use the radon exposure facilities. The purpose of the proposed action is to provide for relocation of the radon generators to a DOE-owned facility and to continue to provide a controlled source of radon-222 for continued use in physical and biological research

  10. The application of air pressure difference in reducing indoor radon concentration

    International Nuclear Information System (INIS)

    Leung, J.K.C.; Tso, M.Y.W.

    2000-01-01

    In densely populated tropical cities like Hong Kong, people usually live and work inside high-rise buildings. And because of the hot and humid climate, air conditioning systems are used throughout the year, particularly in commercial buildings. Previous territory-wide surveys have shown that over 10% of commercial buildings in Hong Kong have indoor radon concentrations above 200 Bq m -3 . Since the major source of indoor radon in high-rise buildings is the building materials, increasing ventilation and applying radon barriers on wall surfaces seem to be the only ways to reduce the indoor radon concentration. But it was noted that the ventilation rate the many commercial buildings are not efficient enough to remove the radon because of various reasons such as energy saving, lack of maintenance, etc. In this study, radon mitigation was achieved by reducing the rate of radon exhaled from the building materials. A special laboratory, which has the capability of simulating any meteorological conditions that could be faced by high-rise buildings in Hong Kong, was built. The reduction of radon exhalation rate by applying pressure difference and temperature difference across walls was studied in the laboratory. This paper summarizes the results and tactics for applying pressure difference in existing commercial buildings. A new technique of reducing radon exhalation rate in new buildings by depressurizing the interior of walls was also developed. Tunnels can be embedded in the concrete walls of new buildings during construction. By using simple vacuum pumps, radon exhalation rate from the walls can be reduced significantly by depressurizing the tunnels. The feasibility and applicability of the technique is presented in this paper. (author)

  11. Sources of error in etched-track radon measurements and a review of passive detectors using results from a series of radon intercomparisons

    International Nuclear Information System (INIS)

    Ibrahimi, Z.-F.; Howarth, C.B.; Miles, J.C.H.

    2009-01-01

    Etched-track passive radon detectors are a well established and apparently simple technology. As with any measurement system, there are multiple sources of uncertainty and potential for error. The authors discuss these as well as good quality assurance practices. Identification and assessment of sources of error is crucial to maintain high quality standards by a measurement laboratory. These sources can be found both within and outside the radon measurement laboratory itself. They can lead to changes in track characteristics and ultimately detector response to radon exposure. Changes don't just happen during etching, but can happen during the recording or counting of etched-tracks (for example ageing and fading effects on track sensitivity, or focus and image acquisition variables). Track overlap means the linearity of response of detectors will vary as exposure increases. The laboratory needs to correct the calibration curve due to this effect if it wishes to offer detectors that cover a range of exposures likely to be observed in the field. Extrapolation of results to estimate annual average concentrations also has uncertainty associated with it. Measurement systems need to be robust, reliable and stable. If a laboratory is not actively and constantly monitoring for anomalies via internal testing, the laboratory may not become aware of a problem until some form of external testing occurs, eg an accreditation process, performance test, interlaboratory comparison exercise or when a customer has cause to query results. Benchmark standards of accuracy and precision achievable with passive detectors are discussed drawing on trends from the series of intercomparison exercises for passive radon detectors which began in 1982, organised by the National Radiological Protection Board (NRPB), subsequently the Health Protection Agency (HPA).

  12. Reduction of radon concentration in a basement workplace: study of the problem and characterization of the main parameters affecting the radon concentration

    International Nuclear Information System (INIS)

    Chiaberto, E.M.; Magnoni, M.; Righino, F.; Costa Laia, R.

    2002-01-01

    In this work is described the method used for the mitigation of high radon concentrations found in a basement workplace, the ARPA laboratory used for the metrology of EMF. In this lab was in fact measured a radon concentration up to 1900 Bq/m 3 , a value largely exceeding the Italian limit for workplaces (500 Bq/m 3 ). The basement workplace affected by radon is a room of around 500 m 3 with no windows and only one door, during work usually close, and therefore with a very low ventilation rate. In this workplace, usually two persons spent about 6 hour per day. Therefore their exposure to the radon and its decay products can attain a considerable value. For this people, accordingly to the accepted dosimetric models, an effective dose of several mSv per year could be estimated (ICRP Publication n. 65, 1993). It is thus important to reduce the radon concentration to acceptable levels, i.e. at least lower than 500 Bq/m 3 . This paper deals not only with the simple method used for the remedial action, but also to the investigation of the relevant parameters affecting the radon concentration. In particular, the monitoring of the radon concentration before and after the remedial action, allowed the calculation of the radon entry rates (Bq/s) and the ventilation rates (s-1) in the different experimental condition

  13. Effect of ventilation on concentrations of indoor radon- and thoron-progeny: Experimental verification of a simple model

    International Nuclear Information System (INIS)

    Sheets, R.W.; Thompson, C.C.

    1993-01-01

    Different models relating the dependence of radon ( 222 Rn)- and thoron ( 220 Rn)-progeny activities on room ventilation rates are presented in the literature. Some of these models predict that, as the rate of ventilation increases, activities of thoron progeny decrease more rapidly than those of radon progeny. Other models predict the opposite trend. In this study alpha activities of the radon progeny, 218 Po, 214 Pb, and 214 Bi, together with the thoron progeny 212 Pb, were measured over periods of several days in two rooms of a closed, heated house. Effective ventilation rates were calculated from measured 214 Pb/ 214 Bi ratios. A simple model in which progeny concentrations decrease by radioactive decay and by dilution with outside air has been used to calculate 212 Pb/ 214 Pb ratios as a function of ventilation rate. Calculated ratios are found to correlate significantly with experimentally-determined ratios (R 2 ∼ 0.5--0.8 at p < 0.005) confirming that, for this house, thoron progeny activities decrease faster than radon progeny activities with increasing rates of ventilation

  14. Health effects of radon

    International Nuclear Information System (INIS)

    Easterly, C.

    1994-01-01

    Exposure of people to radon has taken on increased interest during the last decade because of the understanding that buildings can serve to trap radon and its daughters, and thereby build up undesirable concentrations of these radioactive elements. Numerous studies of underground miners (often uranium miners) have shown an increased risk of lung cancer in comparison with nonexposed populations. Laboratory animals exposed to radon daughters also develop lung cancer. The abundant epidemiological and experimental data have established the carcinogenicity of radon progeny. Those observations are of considerable importance, because uranium, from which radon and its progeny arise, is ubiquitous in the earth's crust, including coal mines. Risk estimates of the health effects of long-term exposures at relatively low levels require continued development, especially to address the potential health effects of radon and radon daughters in homes and occupational settings where the exposure levels are less than levels in underground uranium and other metal mines that have been the subject of epidemiological studies. Two approaches can be used to characterize the lung-cancer risks associated with radon-daughter exposure: mathematical representations of the respiratory tract that model radiation doses to target cells and epidemiological investigation of exposed populations, mainly underground uranium miners. The mathematically-based dosimetric approach provides an estimate of lung cancer risk related to radon-daughter exposure based specifically on modeling of the dose to target cells. The various dosimetric models all require assumptions, some of which are not subject to direct verification, as to breathing rates; the deposition of radon daughters in the respiratory tract; and the type, nature, and location of the target cells for cancer induction. The most recent large committee effort drawn together to evaluate this issue was sponsored by the National Research Council

  15. Functional test of a Radon sensor based on a high-resistivity-silicon BJT detector

    Energy Technology Data Exchange (ETDEWEB)

    Dalla Betta, G.F., E-mail: dallabe@disi.unitn.it [DISI, Università di Trento, and INFN Trento, Trento (Italy); RSens srl, Modena (Italy); Tyzhnevyi, V. [DISI, Università di Trento, and INFN Trento, Trento (Italy); Bosi, A.; Bonaiuti, M. [RSens srl, Modena (Italy); Angelini, C.; Batignani, G.; Bettarini, S.; Bosi, F.; Forti, F.; Giorgi, M.A.; Morsani, F.; Paoloni, E.; Rizzo, G.; Walsh, J. [Dipartimento di Fisica, Università di Pisa, and INFN Pisa, Pisa (Italy); Lusiani, A. [Scuola Normale Superiore and INFN Pisa, Pisa (Italy); Ciolini, R.; Curzio, G.; D' Errico, F.; Del Gratta, A. [Dipartimento di Ingegneria Meccanica, Nucleare e della Produzione, Università di Pisa, Pisa (Italy); Bidinelli, L. [En and tech, Università di Modena e Reggio Emilia, Reggio Emilia (Italy); RSens srl, Modena (Italy); and others

    2013-08-01

    A battery-powered, wireless Radon sensor has been designed and realized using a BJT, fabricated on a high-resistivity-silicon substrate, as a radiation detector. Radon daughters are electrostatically collected on the detector surface. Thanks to the BJT internal amplification, real-time α particle detection is possible using simple readout electronics, which records the particle arrival time and charge. Functional tests at known Radon concentrations, demonstrated a sensitivity up to 4.9 cph/(100 Bq/m{sup 3}) and a count rate of 0.05 cph at nominally-zero Radon concentration.

  16. Radon exhalation rates corrected for leakage and back diffusion – Evaluation of radon chambers and radon sources with application to ceramic tile

    Directory of Open Access Journals (Sweden)

    M. Abo-Elmagd

    2014-10-01

    Full Text Available The natural radon decay, leakage and back diffusion are the main removal processes of radon from its container. Ignoring these processes leads to underestimate the measured value of radon related parameters like exhalation rate and radium content. This work is aimed to evaluate two different radon chambers through determining their leakage rate λv and evaluation of radon source by determine its back diffusion rate λb inside the evaluated radon chambers as well as a small sealed cup. Two different methods are adapted for measuring both the leakage rate and the back diffusion rate. The leakage rate can be determined from the initial slope of the radon decay curve or from the exponential fitting of the whole decay curve. This can be achieved if a continuous monitoring of radon concentration inside the chamber is available. Also, the back diffusion rate is measured by sealing the radon source in the chamber and used the initial slope of the buildup curve to determine λb and therefore the exhalation rate of the source. This method was compared with simple equation for λb based on the ratio of the source to the chamber volume. The obtained results are applied to ceramic tile as an important radon source in homes. The measurement is targeted the ceramic glaze before and after firing as well as the obtained tile after adhere the glaze on the tile main body. Also, six different tile brands from Egyptian market are subjected to the study for comparison.

  17. Radon in buildings: instrumentation of an experimental house

    International Nuclear Information System (INIS)

    Ameon, R.; Diez, O.; Dupuis, M.; Merle-Szeremeta, A.

    2004-01-01

    IRSN decided to develop a code called RADON 2 for conducting simple and methodical studies of indoor radon concentrations. Since a validity check must be performed of the phenomenological model on which the code is based, an experimental program was initiated in 2002, within which a house in Brittany, located on a well-characterized uranium-bearing geological formation, was fitted with special instruments. After characterizing the soil underlying the house, the instrumentation implemented on site continuously monitors a number of parameters to characterize: the radon source term in the building (exhalation rate of 222 Rn at the ground/building interface and at soil surface, radon concentration in the soil and in outdoor air); radon penetration by advection (differential pressure in the house basement); the driving mechanisms for natural ventilation in the house (weather conditions, indoor temperature and relative humidity); radon distribution throughout the house by air flow and radon diffusion (indoor radon concentration at each floor of the house). Using the experimental data acquired over the past two years, the phenomena governing radon penetration inside the house (wind and stack effect) and radon extraction (fresh air supply rate) have been characterized to lay down the bases for validating the newly developed code

  18. Radon in water - fast, simple and sensitive measurement

    International Nuclear Information System (INIS)

    Philipsborn, H. von

    1996-01-01

    Glass fiber filters of a certain brand were found to be very efficient (retention >95%) for adsorption of short-lived radon decay products during filtration of water. Limit of detection is 2 Bq/L in 10 min total time if the dried filters are evaluated in the Living Level Monitor mab LLM 500. Locally high radon concentrations in drinking water have activated country-wide surveys and proposals for compulsory action levels. (orig.) [de

  19. Occupational exposure to radon in Australian Tourist Caves an Australian-wide study of radon levels

    International Nuclear Information System (INIS)

    Solomon, S.B.; Langroo, R.; Peggie, J.R.; Lyons, R.G.; James, J.M.

    1996-02-01

    The study described in this report sets out to determine which Australian show caves have long- term radon levels in excess of the proposed action level of 1000 Bq m -3 . The collaborative study between the Australian Radiation Laboratory (ARL), the University of Sydney and the University of Auckland, was carried out with the support of a Research Grant from Worksafe Australia. The aims of this study were to measure radon levels for each season over a period of one year, at representative sites in all developed show caves around Australia, to determine yearly average radon levels for each cave tour, based on these site measurements, to estimate the radiation doses to the tour guides employed in these caves, and to identify caves with radon concentrations in excess of the action level. (authors)

  20. Radon: a bibliography

    Energy Technology Data Exchange (ETDEWEB)

    Lepman, S.R.; Boegel, M.L.; Hollowell, C.D.

    1981-01-01

    The Lawrence Berkeley Laboratory, with the support of the Department of Energy, has developed a computerized database to manage research information in the area of building ventilation and indoor air quality. This literature survey contains references pertaining to the physical properties of radon and its daughters, instrumentation for their measurement, health effects, surveys and measurements, and regulatory information. The references in the bibliography are sequenced in alphabetical order and abstracts are included when supplied by the author. The objective of this report is to disseminate the bibliographic references compiled at the laboratory relating to radon research portion of the program. Interested database users are encouraged to contact the laboratory to receive instructions for direct database acess. A flyer describing the database is supplied at the end of the bibliography and a brief overview of the Radon Research porgram is given.

  1. Radon: a bibliography

    International Nuclear Information System (INIS)

    Lepman, S.R.; Boegel, M.L.; Hollowell, C.D.

    1981-01-01

    The Lawrence Berkeley Laboratory, with the support of the Department of Energy, has developed a computerized database to manage research information in the area of building ventilation and indoor air quality. This literature survey contains references pertaining to the physical properties of radon and its daughters, instrumentation for their measurement, health effects, surveys and measurements, and regulatory information. The references in the bibliography are sequenced in alphabetical order and abstracts are included when supplied by the author. The objective of this report is to disseminate the bibliographic references compiled at the laboratory relating to radon research portion of the program. Interested database users are encouraged to contact the laboratory to receive instructions for direct database acess. A flyer describing the database is supplied at the end of the bibliography and a brief overview of the Radon Research porgram is given

  2. Determination of the air/water partition coefficient of groundwater radon using liquid scintillation counter

    International Nuclear Information System (INIS)

    Lee, K.Y.; Yoon, Y.Y.; Ko, K.S.

    2010-01-01

    A method was studied for measuring air/water partition coefficient (K air/water ) of groundwater radon by a simple procedure using liquid scintillation counter (LSC). In contrast conventional techniques such as equilibrium partitioning in a closed system or air striping methods, the described method allow for a simple and uncomplicated determination of the coefficient. The (K air/water ) of radon in pure water has been well known quantitatively over a wide range of temperatures. In this work, groundwater samples having high radon concentration instead of distilled water have been used to determine the (K air/water ) of radon in the temperature range of 0-25. Aqueous phase in a closed system was used in this study instead of gaseous phase in conventional methods. Three kinds of groundwater taken from different geologic environments were used to investigate the effect of groundwater properties. With the aim to evaluate the reproducibility of the data an appropriate number of laboratory experiments have been carried out. The results show that tie (K air/water ) of radon in the groundwater is smaller than that in the pure water. However, the temperature effect on the coefficient is similar in the groundwater and the pure water. The method using aqueous phase in a closed system by LSC can be used to determine the (K air/water ) of radon in various groundwaters with a simple procedure. The results will be presented at the NAC-IV conference

  3. The 1996 Radon Intercomparison Exercise at PSI

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.

    1997-05-01

    The 1996 Radon Intercomparison Exercise at PSI was organized by the PSI Reference Laboratory for Radon Gas Activity Concentration Measurements. A total of 14 laboratories, companies and institutions participated with radon gas detectors and measuring instruments. The detectors and instruments were exposed in the PSI radon chamber during seven days in a reference atmosphere with an average radon gas concentration of about 6000 Bqm -3 . Comparison of the results of electret ionization chambers, track etch detectors and measuring instruments with the PSI target value showed the criteria for traceability and reproducibility demanded by the Federal Office for Health for the acknowledgement of Swiss Radon Gas Measurement Laboratories to be fulfilled for all participants. Exposure of track etch detectors stored for more than one year demonstrated that this detector type can suffer sensitivity loss by a too long storage period. (author) figs., tabs., refs

  4. Radon transport from uranium mill tailings via plant transpiration. Final report

    International Nuclear Information System (INIS)

    Lewis, B.A.G.

    1985-01-01

    Radon exhalation by vegetation planted on bare or soil-covered uranium mill wastes was studied based on an assumption that radon transport from soil to atmosphere via plants takes place in the transpiration stream. Results show that radon exhalation by plants is inversely related to water transpired, primarily a dilution effect. Radon released appeared directly related to leaf area, suggesting that radon is carried into the plant by mass flow in water; however, once within the plant, radon very likely diffuses through the entire leaf cuticle, while water vapor diffuses primarily through open stomates. Application of a computerized model for water transpiration to radon exhalation is not immediately useful until the role of water in radon transport is defined throughout the continuum from rooting medium to the atmosphere. Until then, a simple calculation based on leaf area index and Ra-226 concentration in the rooting medium can provide an estimate of radon release from revegetated wastes containing radium

  5. Indoor Radon Concentration Related to Different Radon Areas and Indoor Radon Prediction

    Science.gov (United States)

    Juhásová Šenitková, Ingrid; Šál, Jiří

    2017-12-01

    Indoor radon has been observed in the buildings at areas with different radon risk potential. Preventive measures are based on control of main potential radon sources (soil gas, building material and supplied water) to avoid building of new houses above recommended indoor radon level 200 Bq/m3. Radon risk (index) estimation of individual building site bedrock in case of new house siting and building protection according technical building code are obligatory. Remedial actions in buildings built at high radon risk areas were carried out principally by unforced ventilation and anti-radon insulation. Significant differences were found in the level of radon concentration between rooms where radon reduction techniques were designed and those where it was not designed. The mathematical model based on radon exhalation from soil has been developed to describe the physical processes determining indoor radon concentration. The model is focused on combined radon diffusion through the slab and advection through the gap from sub-slab soil. In this model, radon emanated from building materials is considered not having a significant contribution to indoor radon concentration. Dimensional analysis and Gauss-Newton nonlinear least squares parametric regression were used to simplify the problem, identify essential input variables and find parameter values. The presented verification case study is introduced for real buildings with respect to various underground construction types. Presented paper gives picture of possible mathematical approach to indoor radon concentration prediction.

  6. Canadian population risk of radon induced lung cancer variation range assessment based on various radon risk models

    International Nuclear Information System (INIS)

    Chen, Jing

    2017-01-01

    To address public concerns regarding radon risk and variations in risk estimates based on various risk models available in the literature, lifetime lung cancer risks were calculated with five well-known risk models using more recent Canadian vital statistics (5-year averages from 2008 to 2012). Variations in population risk estimation among various models were assessed. The results showed that the Canadian population risk of radon induced lung cancer can vary from 5.0 to 17% for men and 5.1 to 18% for women based on different radon risk models. Averaged over the estimates from various risk models with better radon dosimetry, 13% of lung cancer deaths among Canadian males and 14% of lung cancer deaths among Canadian females were attributable to long-term indoor radon exposure. (authors)

  7. Occupational exposure to radon in Australian Tourist Caves an Australian-wide study of radon levels

    Energy Technology Data Exchange (ETDEWEB)

    Solomon, S B; Langroo, R; Peggie, J R [Australian Radiation Laboratory. Yallambie, VIC (Australia); Lyons, R G [University of Auckland, Auckland, (New Zealand). Department of Physics; James, J M [University of Sydney, Sydney, NSW (Australia). Department of Chemisty

    1996-02-01

    The study described in this report sets out to determine which Australian show caves have long- term radon levels in excess of the proposed action level of 1000 Bq m{sup -3}. The collaborative study between the Australian Radiation Laboratory (ARL), the University of Sydney and the University of Auckland, was carried out with the support of a Research Grant from Worksafe Australia. The aims of this study were to measure radon levels for each season over a period of one year, at representative sites in all developed show caves around Australia, to determine yearly average radon levels for each cave tour, based on these site measurements, to estimate the radiation doses to the tour guides employed in these caves, and to identify caves with radon concentrations in excess of the action level. (authors) 7 refs., 10 tabs., 2 figs.

  8. Community-based radon education programs

    International Nuclear Information System (INIS)

    Laquatra, J.

    1990-01-01

    This paper reports that in the United States, educational programs about radon gas have been developed and implemented by federal and state government entities and other organizations, including the Cooperative Extension Service and affiliated land grant universities. Approaches have included the production of brochures, pamphlets, workshops for targeted audiences, and consumer telephone hotlines. In a free market for radon mitigation products and services, these efforts can be appropriate for their credibility, lack of bias, and individualized approaches. The purpose of this paper is to report on an educational program about radon undertaken by Cornell Cooperative Extension, including county-based workshops targeted to homeowners, housing professionals, high school teachers, and others. An analysis of survey data from program participants forms the basis for a discussion of the effectiveness of the Cooperative Extension Service in reaching the public about this topic

  9. A model to predict radon exhalation from walls to indoor air based on the exhalation from building material samples

    International Nuclear Information System (INIS)

    Sahoo, B.K.; Sapra, B.K.; Gaware, J.J.; Kanse, S.D.; Mayya, Y.S.

    2011-01-01

    In recognition of the fact that building materials are an important source of indoor radon, second only to soil, surface radon exhalation fluxes have been extensively measured from the samples of these materials. Based on this flux data, several researchers have attempted to predict the inhalation dose attributable to radon emitted from walls and ceilings made up of these materials. However, an important aspect not considered in this methodology is the enhancement of the radon flux from the wall or the ceiling constructed using the same building material. This enhancement occurs mainly because of the change in the radon diffusion process from the former to the latter configuration. To predict the true radon flux from the wall based on the flux data of building material samples, we now propose a semi-empirical model involving radon diffusion length and the physical dimensions of the samples as well as wall thickness as other input parameters. This model has been established by statistically fitting the ratio of the solution to radon diffusion equations for the cases of three-dimensional cuboidal shaped building materials (such as brick, concrete block) and one dimensional wall system to a simple mathematical function. The model predictions have been validated against the measurements made at a new construction site. This model provides an alternative tool (substitute to conventional 1-D model) to estimate radon flux from a wall without relying on 226 Ra content, radon emanation factor and bulk density of the samples. Moreover, it may be very useful in the context of developing building codes for radon regulation in new buildings. - Research highlights: → A model is proposed to predict radon flux from wall using flux of building material. → It is established based on the diffusion mechanism in building material and wall. → Study showed a large difference in radon flux from building material and wall. → Model has been validated against the measurements made at

  10. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report covers the second year of the 28 month grant current grant to Clarkson University to study the chemical and physical behavior of the polonium 218 atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and it dose to the cells in the respiratory tract are to be fully assessed. Two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical process that affect the progeny's atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. This report describes the progress toward achieving these objectives.

  11. Can radon gas measurements be used to predict earthquakes?

    International Nuclear Information System (INIS)

    2009-01-01

    After the tragic earthquake of April 6, 2009 in Aquila (Abruzzo), a debate has begun in Italy regarding the alleged prediction of this earthquake by a scientist working in the Gran Sasso National Laboratory, based on radon content measurements. Radon is a radioactive gas originating from the decay of natural radioactive elements present in the soil. IRSN specialists are actively involved in ongoing research projects on the impact of mechanical stresses on radon emissions from underground structures, and some of their results dating from several years ago are being brought up in this debate. These specialists are therefore currently presenting their perspective on the relationships between radon emissions and seismic activity, based on publications on the subject. (authors)

  12. In-field radon measurement in water: a novel approach

    International Nuclear Information System (INIS)

    Talha, S.A.; Meijer, R.J. de; Lindsay, R.; Newman, R.T.; Maleka, P.P.; Hlatshwayo, I.N.

    2010-01-01

    This paper presents a novel approach of measuring radon in-water in the field by inserting a MEDUSA gamma-ray detector into a 210 L or 1000 L container. The experimental measurements include investigating the effect of ambient background gamma-rays on in-field radon measurement, calibrating the detector efficiency using several amounts of KCl salt dissolved in tap water, and measuring radon in borehole water. The results showed that there is fairly good agreement between the field and laboratory measurements of radon in water, based on measurements with Marinelli beakers on a HPGe detector. The MDA of the method is 0.5 Bq L -1 radon in-water. -- Research highlights: →Radon-in-water, large volume container, in-field measurements, MEDUSA gamma-ray detection system.

  13. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres. Final project report

    International Nuclear Information System (INIS)

    Hopke, P.K.

    1996-09-01

    This report completes Clarkson University's study of the chemical and physical behavior of the 218 Po atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity in the sub-10 nm size range result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and it dose to the cells in the respiratory tract are to be fully assessed. In order to pursue this general goal, two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical processes that affect the progeny's atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. Thus, two sets of specific goals have been established for this project. The specific tasks of the controlled laboratory studies are (1) Determine the formation rates of circ OH radicals formed by the radiolysis of air following radon decay; (2) Examine the formation of particles by the radiolytic oxidation of substances like SO 2 , ethylene, and H 2 S to lower vapor pressure compounds and determine the role of gas phase additives such as H 2 O and NH 3 in determining the particle size; (3) Measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and (4) Measure the neutralization rate of 218 PoO x + in O 2 at low radon concentrations

  14. Remedial measures in Swedish and Norwegian houses - application of radon and radon decay product measurements

    International Nuclear Information System (INIS)

    Just, G.; Philipsborn, H. von; Matolin, M.; Molzahn, D.

    1998-01-01

    Houses and apartments in Sweden and Norway with excessive indoor radon concentrations were studied in detail with a variety of methods, standard and novel ones recently developed. For suitable remediation it is necessary to distinguish soil radon and exhalation from blue (porous) concrete. Our CARBOTEST-S is a simple, sensitive, in-situ method to quantify radon exhalation from existing walls, as well as radon permeability of different protective foils and final quality control of foils applied to existing walls. (orig.) [de

  15. Intercomparison of active and passive instruments for radon and radon progeny in North America

    International Nuclear Information System (INIS)

    George, A.C.; Tu, Keng-Wu; Knutson, E.O.

    1995-02-01

    An intercomparison exercise for radon and radon progeny instruments and methods was held at the Environmental Measurements Laboratory (EML) from April 22--May 2, 1994. The exercise was conducted in the new EML radon test and calibration facility in which conditions of exposure are very well controlled. The detection systems of the intercompared instruments consisted of. (1) pulse ionization chambers, (2) electret ionization chambers, (3) scintillation detectors, (4) alpha particle spectrometers with silicon diodes, surface barrier or diffused junction detectors, (5) registration of nuclear tracks in solid-state materials, and (6) activated carbon collectors counted by gamma-ray spectrometry or by alpha- and beta-liquid scintillation counting. 23 private firms, government laboratories and universities participated with a 165 passive integrating devices consisting of: Activated carbon collectors, nuclear alpha track detectors and electret ionization chambers, and 11 active and passive continuous radon monitors. Five portable integrating and continuous instruments were intercompared for radon progeny. Forty grab samples for radon progeny were taken by five groups that participated in person to test and evaluate their primary instruments and methods that measure individual radon progeny and the potential alpha energy concentration (PAEC) in indoor air. Results indicate that more than 80% of the measurements for radon performed with a variety of instruments, are within ±10% of actual value. The majority of the instruments that measure individual radon progeny and the PAEC gave results that are in good agreement with the EML reference value. Radon progeny measurements made with continuous and integrating instruments are satisfactory with room for improvement

  16. Field demonstrations of radon adsorption units

    International Nuclear Information System (INIS)

    Abrams, R.F.

    1989-01-01

    Four radon gas removal units have been installed in homes in the Northeast U.S. These units utilize dynamic adsorption of the radon gas onto activated charcoal to remove the radon from room air. Two beds of charcoal are used so that one bed removes radon while the second bed is regenerated using outdoor air in a unique process. The beds reverse at the end of a predetermined cycle time, providing continuous removal of radon from the room air. The process and units have undergone extensive development work in the laboratory as well as in homes and a summary of this work is discussed. This work showed that the system performs very effectively over a range of operating conditions similar to those found in a home. The field test data that is presented shows that scale up from the laboratory work was without problem and the units are functioning as expected. This unit provides homeowners and mitigation contractors with another option to solve the radon gas problem in homes, particularly in homes that it is difficult to prevent radon from entering

  17. Estimation of radon progeny equilibrium factors and their uncertainty bounds using solid state nuclear track detectors

    International Nuclear Information System (INIS)

    Eappen, K.P.; Mayya, Y.S.; Patnaik, R.L.; Kushwaha, H.S.

    2006-01-01

    For the assessment of inhalation doses due to radon and its progeny to uranium mine workers, it is necessary to have information on the time integrated gas concentrations and equilibrium factors. Passive single cup dosimeters using solid state nuclear track detectors (SSNTD) are best suited for this purpose. These generally contain two SSNTDs, one placed inside the cup to measure only the radon gas concentration and other outside the cup for recording tracks due to both radon gas and the progeny species. However, since one obtains only two numbers by this method whereas information on four quantities is required for an unambiguous estimation of dose, there is a need for developing an optimal methodology for extracting information on the equilibrium factors. Several techniques proposed earlier have essentially been based on deterministic approaches, which do not fully take into account all the possible uncertainties in the environmental parameters. Keeping this in view, a simple 'mean of bounds' methodology is proposed to extract equilibrium factors based on their absolute bounds and the associated uncertainties as obtained from general arguments of radon progeny disequilibrium. This may be considered as reasonable estimates of the equilibrium factors in the absence of a knowledge of fluctuation in the environmental variables. The results are compared with those from direct measurements both in the laboratory and in real field situations. In view of the good agreement found between these, it is proposed that the simple mean of bounds estimate may be useful for practical applications in inhalation dosimetry of mine workers

  18. Radon emanation from soils

    International Nuclear Information System (INIS)

    Markkanen, M.; Arvela, H.

    1992-01-01

    The results of gamma spectrometric sample measurements of radon ( 222 Rn) emanation coefficients and radium concentrations ( 226 Ra) from about 800 Finnish soil samples are presented. The radon emanation rate was measured in about 400 soil samples, using radon-tight cans and Lucas cells. The effects of water content and temperature on radon emanation were investigated, using various samples of different soil types. Radon emanation and the effect of water content on radon emanation were investigated separately for different grain sizes (samples of till). The results provide some information on radon emanation in different soil types and relate emanation in laboratory conditions to conditions in ground soil. In routine measurements of radon emanation from soil samples, use of a 5% water content was considered advisable. The correction coefficients of radon emanation varied between 0.3 and 1.5, depending on the water content and soil type. At 5% water content, hardly any difference was found between radon emanation at temperatures of 20 and 1 o C. Radon emanation was found to be an inverse function of grain sizes larger than 0.5 mm in diameter. (author)

  19. A new coating material for reducing indoor radon level

    International Nuclear Information System (INIS)

    Zhuo, W.; Tokonami, S.; Ichitsubo, H.; Yamada, Y.; Yamada, Y.

    2002-01-01

    In order to mitigate indoor radon level, a new fast-setting, solvent-free, polyurethane-based coating material was developed. The permeability of radon gas in the new material was estimated with a simple radon permeation test system set up in this study. It was found that the permeation velocity depended on the thickness of the coating material, and a thickness of 2.0 mm of the coating material seems sufficient for preventing radon permeation. The permeability of radon in the coating material was estimated to be (2.2± 0.8)x10 -10 m 2 ·s -1 for a thickness of about 1.0 mm. The value is much lower than those reported for membrane materials and caulking compounds. For its performance test, the coating material was used in an existing room with high radon level. By spraying a thickness of 1.5 mm of the material, the indoor radon level reduced by about 80%

  20. A study of radon indoor concentration; Un estudio de concentracion de radon intramuros

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Ruiz, W.; Segovia, N.; Ponciano, G. [ININ, Gerencia de Ciencias Ambientales, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2000-07-01

    It was realized a study of radon concentration in houses of Mexico City and in a laboratory of the Nuclear Centre of Salazar, State of Mexico. The radon determination in air was realized with solid nuclear track detectors and with Honeywell and Alpha guard automatic equipment. The results show that the majority of houses have values under 148 Bq/m{sup 3} obtaining some housings with upper values located in the Lomas zone. A study in smokers houses and another of controls showed very similar distributions. It was studied the day time fluctuations finding that radon increases considerably during the dawn. Some upper values obtained in a laboratory of the Nuclear Centre were remedied with ventilation. (Author)

  1. Study of radon emanation from uranium mill tailings. Relations between radon emanating power and physicochemical properties of the material

    International Nuclear Information System (INIS)

    Pellegrini, D.

    1999-01-01

    The uranium extraction from ores leads to large amounts of mill tailings still containing radionuclides, such as thorium-230 and radium-226, which generate radon-222. Without protective action, radon exposition may be high enough to cause concern for health of populations living in the vicinity of an uranium mill tailings disposal. This exposition pathway has therefore to be taken into account in the radiological impact studies. The emanating power, i.e. the part of radon atoms which escape from the solid particles, is directly involved in the radon source term evaluation. It may be determined for a given material by laboratory measurements. Emanating powers from 0.08 to 0.33 have been obtained for mill tailings from Jouac (Limousin, France), at various moisture contents. In order to reduce the relations of dependence between some of the emanation parameters, more simple phases, kaolinite and polymeric resins, have been studied. Those experiments have led us to the selection of the mechanisms and the parameters to consider for the development of an emanation modelling. The whole of the results obtained point out the radon sorption, in various proportions depending on the materials. The moisture content influence on the emanation from materials containing fine particles have been confirmed: the emanation increases with this parameter until a continuous water film surrounding the particles have been formed, and then become constant. This 'water effect' occurs in a moisture content range, which depends on the material porosity. Elsewhere, the presence of amorphous phases may led to a high radon emanation. (author)

  2. Quality assurance for environmental radon measurements by LR115 nuclear track detectors

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A [National Network of Radiation Physics, Atomic Energy Authority, Cairo (Egypt); Hafez, A F [Physics Department, Faculty of Science, Alexandria Univercity, Alexandria (Egypt); Hussein, A S [Radiation Protection Department, Nuclear Power Plants Authority, Cairo (Egypt)

    2007-06-15

    Passive radon dosimeters based on LR115 nuclear track detectors are very attractive for assessment of radon exposure. For developing countries wishing to undertake national radon survey the most appropriate techniques are those making use of LR115 detectors. These detectors are small, cheap, simple, and non-hazardous and provide an entirely adequate tool for large scale use in assessing levels of radon over several months because of the short - term fluctuations in radon concentrations. In this paper, the principles and philosophy in order to improve the quality and reliability of radon exposure under a quality assurance (QA) program are presented . Also examples of how a QA program of radon measurements by LR115 detectors using the can-techniques are well defined and applied.

  3. Quality assurance for environmental radon measurements by LR115 nuclear track detectors

    International Nuclear Information System (INIS)

    Gomaa, M.A.; Hafez, A.F.; Hussein, A.S.

    2007-01-01

    Passive radon dosimeters based on LR115 nuclear track detectors are very attractive for assessment of radon exposure. For developing countries wishing to undertake national radon survey the most appropriate techniques are those making use of LR115 detectors. These detectors are small, cheap, simple, and non-hazardous and provide an entirely adequate tool for large scale use in assessing levels of radon over several months because of the short - term fluctuations in radon concentrations. In this paper, the principles and philosophy in order to improve the quality and reliability of radon exposure under a quality assurance (QA) program are presented . Also examples of how a QA program of radon measurements by LR115 detectors using the can-techniques are well defined and applied

  4. On the behaviour of radon in indoor air

    International Nuclear Information System (INIS)

    Lehtimaeki, M.; Kivistoe, T.

    1983-01-01

    In this work the behaviour of radon in indoor air has been studied. A simple mathematical model is presented to describe the variations in radon concentration in case of a periodic ventilation. This model has been tested with the aid of long-term measurements in two office buildings, in a large shipyard hall, and in a dwelling. The variations predicted by the simple model were observed in all buildings studied. It seems even possible that if the mixing of radon in the building is effective, the radon measurements can be used in estimating the infiltration rates. The measurement in one of the office buildings, however, indicated that the mixing of radon in a many-storied building can be extremely incomplete. The measurements also indicate that the soil can be a very important source of radon. (orig.) [de

  5. Intercomparison 2003 for Radon measurement services at PSI

    CERN Document Server

    Butterweck, G

    2003-01-01

    Twelve radon measurement services participated in the 2003 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut (PSI) during March 13th to 24th, 2003. Ten of these laboratories were approved by the Swiss Federal Office of Public Health and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas detectors (etched-track and electret ionisation chambers) and instruments (ionisation chambers and electrostatic precipitation) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 1950 Bqm sup - sup 3 leading to a radon gas exposure of 517 kBqhm sup - sup 3. Additional five electret-detectors of an approved measuring service were purchased by the Swiss Federal Office of Public Health for a spot check. Two of these were exposed as described above, two had an exposure of 247 kBqhm sup - sup 3 at an average radon concen...

  6. The 2010 calibration campaign for radon gas measuring instruments at PSI

    International Nuclear Information System (INIS)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2011-01-01

    Twenty radon measurement services or the respective analytical laboratories participated in the 2010 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) from August 27 th to August 31 st , 2010 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (track-etch, electronic and electret) and instruments (ionisation chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 595 Bq m -3 leading to a radon gas exposure of 57 kBq h m -3 . The exposure of 57 kBq h m -3 was close to the lower value of the measuring range defined in the Radon Measurement Ordinance ('Radon-Messmittelverordnung'). (authors)

  7. Evaluation of experiences in long-term radon and radon-daughter measurements

    International Nuclear Information System (INIS)

    Young, J.A.; Jackson, P.O.; Thomas, V.W.

    1982-12-01

    Pacific Northwest Laboratory (PNL) is performing side-by-side measurements of radon and radon daughter concentrations using several instruments and techniques, and is comparing these measurements with side-by-side measurements made by other investigators at other locations. The standard deviation of the differences between the (natural) logarithms of the Terradex Track Etch radon concentrations and the logarithms of the Radon Progency Integrating Sampling Units (RPISU) radon daughter concentrations (S.D.-ln) measured in 50 buildings in Edgemont, South Dakota, was 0.37. Using this S.D.-ln, it can be calculated that if the Track Etch radon daughter concentration is 0.010 WL there should be only a 14% probability that the RPISU average would be greater than 0.015 WL, and only a 3% probability tht the RPISU average would be greater than 0.020 WL. If buildings had been cleared from remedial action when the Track Etch averages were less than 0.10 WL, then about 61% of the buildings would have been cleared from remedial action, and only a few percent of these buildings would have actually had average RPISU concentrations greater than 0.015 WL. The S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements made by ALARA at Grand Junction, the PERM radon measurements and the MOD-225 radon daughter measurements made by Mound Facility at Canonsburg and Middlesex, and the PERM and Track Etch radon measurements made by Mound Facility at Salt Lake City were similar to the S.D.-ln between the Track Etch radon measurements and the RPISU radon daughter measurements at Edgemont

  8. Development and testing of the detector for monitoring radon double-filter method

    International Nuclear Information System (INIS)

    Sevcik, P.

    2008-01-01

    Applications of physics in the study of radon transport processes in the atmosphere and of testing of atmospheric transport models require sensitive detection devices with low maintenance requirements. The most precise devices involved in the worldwide monitoring program of the atmosphere (GAW) determine volume activity of radon from a variety of daughter products of 222 Rn, resulting in a working volume of the detector (double-filter method). The purpose of this work was to explore theoretically and experimentally the possibilities and limits of a particular simple implementation of this procedure. Tested apparatus consists of a 200 dm 3 chamber (metal drum), where are developed transformation products of radon and semiconductor detector with surface barrier, which registers α particles from the conversion of daughter products 222 Rn collected on a filter at the outlet of the chamber. Testing of the apparatus takes place in the atmosphere with higher concentrations of radon. The measured variations of volume activities 222 Rn have the same character as the variations of radon concentration in the air in laboratory. Minimum detectable activity at 95% significance level is 16.0 Bq.m -3 at a pumping speed of the air 20 dm 3 .min - 1 and 13.0 Bq.m -3 at a pumping rate 24 dm 3 .min -1 . These values are still too high for using the apparatus for measuring in external atmosphere. The main limit of the apparatus is a capture of transformation products arising on the inner walls of the chamber (plate-out effect). The effectiveness of collecting 218 Po from the chamber on the filter in our measurements was only 2.8%. But we managed to increase it to about 20% by adding aerosol delivery systems into production chamber of transformation products of radon. It turns out that based on this principle can be made sensitive and continuously working monitor of radon. (author)

  9. Radon concentration in a house of Calvados

    International Nuclear Information System (INIS)

    Leleyter, L.; Riffault, B.; Mazenc, B.

    2010-01-01

    Recent studies indicate a link between the risk of lung cancer and residential radon exposure. However, in France, awareness of this problem was made relatively late. Accordingly this study examines the radon concentration in a private home in Calvados (Normandy region). Findings show that the presence of a fireplace in a house can accelerate radon convective transfer, and that simple adjustments to interior and exterior accommodation can significantly reduce radon concentrations in the home. (authors)

  10. Experimental, statistical, and biological models of radon carcinogenesis

    International Nuclear Information System (INIS)

    Cross, F.T.

    1991-09-01

    Risk models developed for underground miners have not been consistently validated in studies of populations exposed to indoor radon. Imprecision in risk estimates results principally from differences between exposures in mines as compared to domestic environments and from uncertainties about the interaction between cigarette-smoking and exposure to radon decay products. Uncertainties in extrapolating miner data to domestic exposures can be reduced by means of a broad-based health effects research program that addresses the interrelated issues of exposure, respiratory tract dose, carcinogenesis (molecular/cellular and animal studies, plus developing biological and statistical models), and the relationship of radon to smoking and other copollutant exposures. This article reviews experimental animal data on radon carcinogenesis observed primarily in rats at Pacific Northwest Laboratory. Recent experimental and mechanistic carcinogenesis models of exposures to radon, uranium ore dust, and cigarette smoke are presented with statistical analyses of animal data. 20 refs., 1 fig

  11. Wire screens as a tool for survey measurements of the unattached radon progeny in mines

    International Nuclear Information System (INIS)

    Janica, R.

    1996-07-01

    The radon hazard in mines is assessed by measuring the radioactivity accumulated on filters through which air is forced to flow. The filter collects both forms of the short-lived radon progeny, attached and unattached, and, therefore, the assessment is based on the measurement of the total radon progeny. Because of the special radiological significance of the unattached fraction of the short-lived radon progeny, the estimation of the radiation hazard to miners would be improved if the unattached fraction could be measured. This report describes two methods of measurement for the simultaneous determination of the unattached and the total radon progeny. The proposed methods comply with the criterion of practicality (imposed by the working conditions in the mine environment), that is, they are implemented using standard survey equipment and simple procedures. Both methods use wire screens to collect, preferentially, the unattached fraction. According to the first method, air is sampled through a wire screen and a backup filter, and the radioactivity accumulated on both the filter and the wire screen are measured separately using standard counting protocols (e.g. the Kusnetz protocol). The wire screen's efficiency for collecting the unattached radon progeny is determined, in advance, under laboratory conditions. The method assumes the validity of the collection efficiencies when the screens are used under field conditions. To avoid the uncertainty of the lab-determined collection efficiency, a new measuring method was proposed based on the sampling of air through two screens in series and a backup filter. The measurement of the ratio of the activities deposited on both screens allows an estimation of the screen collection efficiency under field conditions. Once this is done, the 'unattached fraction' and total radon progeny are determined by counting only one of the screens and the backup filter as described in the previous method. (author). 73 refs., 8 tabs., 21 figs

  12. Ethanol as radon storage: applications for measurement

    International Nuclear Information System (INIS)

    Winter, I.; Philipsborn, H. von

    1997-01-01

    Ethanol as Radon Storage: Applications for Measurement Ethanol has a solubility for radon of 6 Bq/l per kBq/m 3 air, 24 times higher than water. On filtration of ethanol, radon decay products are completely adsorbed on glass fiber filters, as previously reported for water. Hence: 1. A new simple method for measuring radon in soil air, without expensive equipment. 2. The production of mailable radon calibration sources ('radonol') with 50-100 kBq/l in PET-bottles with 3.8 days half-life, using uraniferous rocks as primary source. (orig.) [de

  13. Intercomparison of radon gas detectors 1997 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck-Dempewolf, Gernot

    1998-05-01

    Between Nov 14 and Nov 20, 1997, the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut performed the 1997 Radon Intercomparison Exercise. Radon gas detectors and instruments were exposed in the PSI Radon Chamber during seven days in a reference atmosphere with an average radon gas concentration of 3860 Bqm -3 . The majority of the participants at this intercomparison were Swiss Radon Gas Measurement Laboratories acknowledged by the Swiss Federal Office for Health. Criteria for this acknowledgement are a deviation of the measurement results to the reference value below 15% (traceability criterion) and a standard deviation of the mean of five detector measurement results below 15% (reproducibility criterion). With the exception of three participants, the results of electret ionisation chambers, track etch detectors and measuring instruments fulfilled the demanded traceability and reproducibility criteria. (author)

  14. Research on radon flux reduction from uranium mill tailings

    International Nuclear Information System (INIS)

    Overmyer, R.F.; Thamer, B.J.; Nielson, K.K.; Rogers, V.C.

    1980-01-01

    Radon flux reduction from tailings may be accomplished by the use of an impermeable cover to contain the radon until it decays (half life is 2.8 days). The use of a thick, relatively impermeable cover can attenuate radon flux because a large fraction of the radon would decay before it diffuses through the cover into the atmosphere. This method of reducing radon flux may require soil cover thicknesses on the order of 10 feet. In some locations, obtaining 10 feet of soil to cover 200 acres of tailings may be difficult or may lead to other significant environmental impacts. The Department of Energy is sponsoring research to identify alternatives to thick soil covers for reducing radon flux from uranium tailings to meet the forthcoming standards. The two most effective and practical materials tested thus far are Calcilox and asphalt emulsion. Currently, asphalt emulsions are being tested at the Grand Junction tailings pile in Grand Junction, Colorado, by Battelle Pacific Northwest Laboratory. Other asphalt formulations, such as foamed asphalt that requires less water than asphalt emulsions, may be practical and will be tested this year. Some sulfur-based materials and sulfur-extended asphalt also appear promising and will be tested for effectiveness in reducing radon flux. It is also important to investigate methods of applying various stabilizers to inactive tailings piles in various physical conditions of moisture content, and physical stability. Finally, since the EPA standards for remedial action at tailings piles are stated in terms of radon flux, it is important that radon flux measurements be standardized so that reliable flux measurements can be obtained and directly compared among various laboratories

  15. Optimized collection, storage and measurement of radon and radon decay products - school experiments

    International Nuclear Information System (INIS)

    Philipsborn, H. von; Geipel, R.; Just, G.

    1998-01-01

    Schools are expected more than ever to teach in physics and chemistry an understanding of radioactivity in its many aspects. Simple experiments on the occurrence, the measurement and the properties of radionuclides are necessary for true understanding. Such experiments are now possible with novel methods of collection and storage of ubiquitous radon and radon decay products from air, water and solids. (orig.) [de

  16. A Simple System for Observing Dynamic Phase Equilibrium via an Inquiry-Based Laboratory or Demonstration

    Science.gov (United States)

    Cloonan, Carrie A.; Andrew, Julie A.; Nichol, Carolyn A.; Hutchinson, John S.

    2011-01-01

    This article describes an activity that can be used as an inquiry-based laboratory or demonstration for either high school or undergraduate chemistry students to provide a basis for understanding both vapor pressure and the concept of dynamic phase equilibrium. The activity includes a simple setup to create a closed system of only water liquid and…

  17. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report describes studies on the chemical and physical behavior of the [sup 218]Po atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity in the sub-10 nm size range result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and its dose to the cells in the respiratory tract are to be fully assessed. The specific tasks of the controlled laboratory studies are to determine the formation rates of [center dot]OH radicals formed by the radiolysis of air following radon decay, to examine the formation of particles by the radiolytic oxidation of substances like SO[sub 2] ethylene, and H[sub 2]S to lower vapor pressure compounds and determine the role of gas phase additives such as H[sub 2]O and NH[sub 3] in determining the particle size, to measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and to measure the neutralization rate of [sup 218]Po[sub x][sup +] in O[sub 2] at low radon concentrations. Tasks of the exposure studies in occupied indoor spaces are to initiate measurements of the activity size distributions in actual homes with occupants present so that the variability of the indoor activity size distributions can be assessed with respect to indoor aerosol sources and general lifestyle variations of the occupants, to initiate a prospective study of the utility of measurement of deposited [sup 210]Pb embedded in glass surfaces as a measure of the long-term, integrated exposure of the population to radon, and to develop the methodology to determine the hygroscopicity of the indoor aerosol so that the changes in deposition efficiency of the radioactive indoor aerosol with hygroscopic growth in the respiratory tract can be assessed.

  18. Study of the calibration of the medical physics department - radon dosimeter in a radon facility

    International Nuclear Information System (INIS)

    Nikololpoulos, D.; Louizi, A.; Papadimitriou, D.; Proukakis, C.

    1997-01-01

    Several techniques have been developed to measure radon indoors.The use of a Solid State Nuclear Track Detector closed in a cup, has turned out to be the most appropriate for long term measurements. The Medical Physics Department of the Athens University is carrying out radon measurements in dwellings, apartments, outdoor air and mines since 1996. For this purpose a simple device, the so called Medical Physics Department radon dosimeter, has been constructed, which measures the radon concentration averaged over a long period of time. In the present paper the calibration technique introduced and the results of the calibration of the Medical Physics Department. (authors)

  19. Influence of a component of solar irradiance on radon signals at 1000 meter depth at the Gran Sasso Laboratory, Italy

    Science.gov (United States)

    Gazit-Yaari (Charit-Yaari), N.; Steinitz, G.; Piatibratova, O.

    2012-04-01

    Exploratory monitoring of radon is conducted at one site at the deep underground Gran Sasso National Laboratory (LNGS; 1,000m below the surface). Monitoring is performed in a small secluded space separated by a sealed partition from the entirety of the laboratory environment in air in contact with the exposed surrounding calcareous country rock. Overall radon levels are low (0.45 kBq/m3). Utilizing both alpha and gamma-ray detectors measurements (15-minute resolution) cover a time span of ca. 600 days. Systematic and recurring radon signals are recorded consisting of two primary signal types: a) non-periodic Multi-Day (MD) signals lasting 2-10 days, and b) Daily Radon (DR) signals - which are of a periodic nature exhibiting a primary 24-hour cycle. Temperature in the closed enclosure is stable (11.5±0.3 °C) and pressure reflects above surface barometric variations. Analysis and comparison in the time and frequency domains (FFT) of local environmental data (P, T) indicates that these do not drive radon variation in air at the site. The phenomenology of the MD and DR signals is similar to situations encountered at other locations where radon is monitored with a high time resolution in geogas at upper crustal levels. Using the Continuous Wavelet Transform analysis tool a different variation pattern is observed for time series consisting of day-time and night-time measurement of the gamma radiation from radon progeny. Applying the same analysis to the time series of local air pressure does not reveal a day-time and night-time difference. The observation of a differing day/night pattern in the gamma radiation from radon at LNGS is similar to further occurrences at other subsurface locations. Production of a day/night pattern must be related to rotation of Earth around its axis. This phenomenon is a further confirmation of the recent proposition as to the influence of a component of solar irradiance on the nuclear radiation from radon in air. The occurrence of these

  20. A universal laboratory method for determining physical parameters of radon migration in dry granulated porous media.

    Science.gov (United States)

    Ye, Yong-Jun; Zhang, Yun-Feng; Dai, Xin-Tao; Ding, De-Xin

    2017-10-01

    The particle size and heaped methods of exhalation media have important effects on physical parameters, such as the free radon production rate, porosity, permeability, and radon diffusion coefficient. However, existing methods for determining those parameters are too complex, and time-consuming. In this study, a novel, systematic determining method was proposed based on nuclide decay, radon diffusion migration theory, and the mass conservation law, and an associated experimental device was designed and manufactured. The parameters of uranium ore heap and sandy soil of radon diffusion coefficient (D), free radon production rate (α), media permeability (k), and porosity (ε) were obtained. At the same time, the practicality of the novel determining method was improved over other methods, with the results showing that accuracy was within the acceptable range of experimental error. This novel method will be of significance for the study of radon migration and exhalation in granulated porous media. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Concentration en radon dans une maison du Calvados

    Science.gov (United States)

    Leleyter, Lydia; Riffault, Benoit; Mazenc, Bernard

    2010-03-01

    Recent studies indicate a link between the risk of lung cancer and residential radon exposure. However, in France, awareness of this problem was made relatively late. Accordingly this study examines the radon concentration in a private home in Calvados. Findings show that the presence of a fireplace in a house can accelerate radon convective transfer, and that simple adjustments to interior and exterior accommodation can significantly reduce radon concentrations in the home.

  2. OECD/NEA and CEC intercalibration and intercomparison programme for Radon

    International Nuclear Information System (INIS)

    Solomon, S.B.; Knutson, E.O.

    1991-01-01

    Intercomparison of measurements of radon daughter activity concentration, unattached fraction and aerosol size distribution of radon daughters, was carried out by three of the reference laboratories: Australian Radiation Laboratory (ARL), US Department of Energy, Environmental Measurements Laboratory (EML) and US Department of Industry, Bureau of Mines (USBM), over the period March 17 to 21 1986, using the radon test chamber at the Australian Radiation Laboratory in Melbourne. The methodology, protocols and results for these measurements are described in detail. The results showed no systematic differences between the three laboratories, within the limits set by the counting statistics. In intercomparing methods for unattached fraction measurement, two of the reference laboratories (ARL and EML) used the single screen method. Good agreement was obtained between the two laboratories. EML and USBM also used graded screen devices for sizing these so-called unattached radon daughters. At the time of these measurements, the graded screen analysis methods available were of a preliminary nature. The ultrafine aerosol size distributions derived by EML and USBM show reasonable agreement in the position and magnitude of the derived peaks. The results of the measurements of the radon daughter aerosol size distributions between ARL, EML and USBM showed good agreement within the regions of overlap of the instrument response. 16 refs., 13 tabs., 11 figs

  3. Least-squares reverse time migration with local Radon-based preconditioning

    KAUST Repository

    Dutta, Gaurav

    2017-03-08

    Least-squares migration (LSM) can produce images with better balanced amplitudes and fewer artifacts than standard migration. The conventional objective function used for LSM minimizes the L2-norm of the data residual between the predicted and the observed data. However, for field-data applications in which the recorded data are noisy and undersampled, the conventional formulation of LSM fails to provide the desired uplift in the quality of the inverted image. We have developed a leastsquares reverse time migration (LSRTM) method using local Radon-based preconditioning to overcome the low signal-tonoise ratio (S/N) problem of noisy or severely undersampled data. A high-resolution local Radon transform of the reflectivity is used, and sparseness constraints are imposed on the inverted reflectivity in the local Radon domain. The sparseness constraint is that the inverted reflectivity is sparse in the Radon domain and each location of the subsurface is represented by a limited number of geologic dips. The forward and the inverse mapping of the reflectivity to the local Radon domain and vice versa is done through 3D Fourier-based discrete Radon transform operators. The weights for the preconditioning are chosen to be varying locally based on the relative amplitudes of the local dips or assigned using quantile measures. Numerical tests on synthetic and field data validate the effectiveness of our approach in producing images with good S/N and fewer aliasing artifacts when compared with standard RTM or standard LSRTM.

  4. E-perm radon monitors for determining waterborne concentrations of dissolved in radon 222Rn

    International Nuclear Information System (INIS)

    Jester, W.A.; Kotrappa, P.

    1989-01-01

    This paper describes a simple and relatively inexpensive method in which E-Perm radon monitors are used to determine the concentration of dissolved 222 Rn in drinking water. This procedure takes advantage of E-Perm's ability to accurately measure the integral radon exposure under conditions of high humidity. The method was evaluated against the liquid scintillation procedure recommended by the U.S. Environmental Protection Agency (EPA) and was found to give excellent agreement. An E-perm is an electret ion chamber that consists of a small chamber constructed from a conducting plastic and having an electret at its base and a filtered air inlet at the top. The technique described in this paper takes advantages of E-Perm's insensitivity to high humidity

  5. Controlling exposure to radon, France, December 2006

    International Nuclear Information System (INIS)

    Godet, J.L.; Perrin, M.L.; Dechaux, E.; Pineau, C.

    2007-01-01

    Controlling exposure to radon, France, December 2006 Exposure to radon, along with medical exposure, is the leading source of the French population exposure to ionizing radiation. Radon is a confirmed cause of lung cancer in man (classified in group I by the international Agency for research on Cancer (I.A.R.C.)). According to available estimates, the numbers of lung cancers attributable to radon exposure in France are far fewer than those caused by tobacco. However, according to a recent European study, around 9% of lung cancers in Europe may be caused by radon. Thus, due to the number of people exposed, radon has become a public health issue which calls for action, considering that exposure can be significantly reduced by implementing measures which are often simple. Since 2002, the Nuclear Safety Authority (Asn) has proceeded in implementing a new regulatory framework for the risk management related to the presence of radon in public places. The new system is now fully operational. In addition, based on the initiatives adopted by the government in June 2004 in the context of the National Health and Environment Plan (P.N.S.E.), the Asn drew up a plan in 2005, in collaboration with the Ministry for Urban Planning and Construction, to coordinate the actions of various national bodies involved in this field. This three-pronged strategy is as follows: - Creation of a new risk management policy related to the presence of radon in existing homes and in new buildings; - Supporting and controlling the implementation of regulations for managing radon related risks in public places; - Improvement and dissemination of knowledge on radon exposure and its related risks. (author)

  6. Development of a quality assured calibration method for the PSI radon chamber reference atmosphere

    International Nuclear Information System (INIS)

    Schuler, C.; Butterweck-Dempewolf, G.; Vezzu, G.

    1997-01-01

    Radon detectors and measuring instruments are calibrated at the PSI Reference Laboratory for Radon Gas Concentration Measurements by exposing them to a calibrated radon reference atmosphere in the PSI radon chamber. A sophisticated and quality assured calibration technique was developed which guarantees the traceability of this radon chamber reference atmosphere to standards of internationally acknowledged primary laboratories. (author) 2 figs., 2 refs

  7. An international cooperation by using an all-encompassing passive radon monitor

    International Nuclear Information System (INIS)

    Tommasino, L.; Chen, J.; Falcomer, R.; Janik, M.; Kanda, R.; DeFelice, F.; Cardellini, F.; Trevisi, R.; Leonardi, F.; Magnoni, M.; Chiaberto, E.; Agnesod, G.; Ragani, M. Faure; Espinosa, G.; Golzarri, J.; Kozak, K.; Mazur, J.

    2017-01-01

    The recently developed radon film-badge makes it possible to measure radon indoors, in soil, in water and/or in aqueous media (e.g. mud). As a result of its wide response linearity, this monitor has been successfully used to measure radon in-water with concentrations from 10 to ∼10 000 Bq/L. By exploiting the unique characteristics of this badge, a mini-survey has been carried out by Health Canada in which radon in water was measured from 12 private wells, as well as in tap water originating from the Ottawa River. Due to the widespread interest of different laboratories in using these passive monitors, laboratories were provided with plastic films to construct their own badges by using in-house CR-39 detectors. Monitors were then irradiated by a known radon concentration at the National Institute of Radiation Metrology (ENEA) s radon chamber and sent back to each laboratory for processing and counting. Even though these laboratories have been using different etching- and counting procedures, the film-badge responses varied only within ∼12%. (authors)

  8. A study of radon indoor concentration

    International Nuclear Information System (INIS)

    Pena, P.; Ruiz, W.; Segovia, N.; Ponciano, G.

    2000-01-01

    It was realized a study of radon concentration in houses of Mexico City and in a laboratory of the Nuclear Centre of Salazar, State of Mexico. The radon determination in air was realized with solid nuclear track detectors and with Honeywell and Alpha guard automatic equipment. The results show that the majority of houses have values under 148 Bq/m 3 obtaining some housings with upper values located in the Lomas zone. A study in smokers houses and another of controls showed very similar distributions. It was studied the day time fluctuations finding that radon increases considerably during the dawn. Some upper values obtained in a laboratory of the Nuclear Centre were remedied with ventilation. (Author)

  9. A summary of EPA radon chamber tests and results for rounds 3 and 4 of the National Radon Measurement Proficiency Program

    International Nuclear Information System (INIS)

    Smith, J.M.; Sensintaffar, E.L.

    1993-02-01

    The US Environmental Protection Agency's Office of Radiation and Indoor Air (ORIA) established the National Radon Measurement Proficiency (RMP) Program in 1986. Through this voluntary program, participants can demonstrate their ability to measure radon and/or radon decay products by submitting their detection devices to a blind test in a designated radon chamber. In this report, two EPA radon and radon decay products test chambers (chambers A and C) located at the National Air and Radiation Environmental Laboratory in Montgomery, Alabama are described. These chambers were used to expose detectors submitted for testing in Round 4 of the National Radon Measurement Proficiency Program and are used routinely for calibration purposes. Also described are the measurement and calibration procedures which were used to establish the official target values for radon and radon decay products concentrations during RMP Round 4 testing. The results for RMP Round 3 (conducted at the US DOE Environmental Measurements Laboratory radon chamber in New York) and RMP Round 4 (conducted in the two NAREL chambers) are discussed and compared. Following Round 4, the NAREL staff analyzed the collective performance for each measurement method tested in these rounds and found that all methods agreed with the target values within expected limits except for RPISU's and charcoal adsorbers. After analyzing the RMP4 results, NAREL staff spent several months evaluating the difference in charcoal adsorber response between Round 3 and 4 by performing radon chamber tests using EPA 4-inch, open-faced charcoal adsorbers

  10. Element of risk: The politics of radon

    International Nuclear Information System (INIS)

    Cole, L.A.

    1994-01-01

    The recent history of the Environmental Protection Agency's (EPA) approach to managing the risk of indoor radon offers a rich base from which to consider US practice in risk assessment, management, and communication. The biological evidence of risks from high-level exposure to radon is in many ways stronger--and the gap to be spanned by extrapolation from laboratory animal studies to ambient exposures narrower--than for many of the toxic and hazardous air pollutants that have been the focus of EPA regulatory attention. The epidemiological evidence about radon is complicated by a number of confounding variables, but this is often the state of epidemiological evidence. Radon has also been the focus of a considerable amount of research on risk communication. To complete the promising ingredients, disagreements between federal regulators at EPA and managers of federal nuclear programs run by the Department of Energy (DOE) concerning radon from uranium mill tailings, for example, and other issues in radiation health physics offer a rich array of opportunities to explore issues in federal bureaucratic politics. This book provides a straightforward report of much of the development of US policy on indoor radon over the past decade. As such, it gives readers unfamiliar with the evolution of radon regulation an opportunity to come quickly up to speed on many historical details

  11. Characterization of radon entry rates and indoor concentrations in underground structures

    International Nuclear Information System (INIS)

    Borak, T.B.; Whicker, F.W.; Fraley, L.; Gadd, M.S.; Ibrahim, S.A.; Monette, F.A.; Morris, R.; Ward, D.C.

    1992-01-01

    An experimental facility has been designed to comprehensively determine the influence of soil and meterological conditions on the transport of radon into underground structures. Two identical basements are equipped to continuously monitor pressure differentials, temperatures, soil moisture, precipitation, barometric pressure, wind speed, wind direction, natural ventiliation rates, and radon concentrations. A computerized data acquisition system accumulates and processes data at the rate of 6000 points per day. The experimental design is based on performing experiments in one structure, with the other used as a control. Indoor radon concentrations have temporal variations ranging from 150 to 1400 Bq m -3 . The corresponding entry rate of radon ranges from 300 to 10,000 Bq h -1 . When the radon entry rate is high, the indoor radon concentration decreases, whereas elevated radon concentrations seem to be associated with slow but persistent radon entry rates. This inverse relationship is partially due to compensation from enhanced natural ventilation during periods when the radon entry rate is high. Correlations between measured variables in the soil and indoor-outdoor atmospheres are used to interpret these data. This laboratory has the capability to generate essential data required for developing and testing radon transport models

  12. 1982 radon intercomparison exercises at EML

    International Nuclear Information System (INIS)

    Fisenne, I.M.; George, A.C.; Keller, H.W.

    1983-03-01

    This report summarizes the results of two radon measurement intercomparison exercises held in 1982. Sixteen organizations, including five United States federal departments, two state governments, two national laboratories, three universities, three private sector laboratories and Swedish National Institute participated in these exercises. The results indicate good agreement among the participants at the 30 pCi 222 Rn/L level. With the continued interest and cooperation of groups involved in radon measurements, twp intercomparison exercises are planned during 1983

  13. Predicting radon flux from uranium mill tailings

    International Nuclear Information System (INIS)

    Freeman, H.D.; Hartley, J.N.

    1983-11-01

    Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) office, is developing technology for the design of radon barriers for uranium mill tailings piles. To properly design a radon cover for a particular tailings pile, the radon flux emanating from the bare tailings must be known. The tailings characteristics required to calculate the radon flux include radium-226 content, emanating power, bulk density, and radon diffusivity. This paper presents theoretical and practical aspects of estimating the radon flux from an uranium tailings pile. Results of field measurements to verify the calculation methodology are also discussed. 24 references, 4 figures, 4 tables

  14. Modeled atmospheric radon concentrations from uranium mines

    Energy Technology Data Exchange (ETDEWEB)

    Droppo, J.G.

    1985-04-01

    Uranium mining and milling operations result in the release of radon from numerous sources of various types and strengths. The US Environmental Protection Agency (EPA) under the Clean Air Act, is assessing the health impact of air emissions of radon from underground uranium mines. In this case, the radon emissions may impact workers and residents in the mine vicinity. To aid in this assessment, the EPA needs to know how mine releases can affect the radon concentrations at populated locations. To obtain this type of information, Pacific Northwest Laboratory used the radon emissions, release characteristics and local meterological conditions for a number of mines to model incremental radon concentrations. Long-term, average, incremental radon concentrations were computed based on the best available information on release rates, plume rise parameters, number and locations of vents, and local dispersion climatology. Calculations are made for a model mine, individual mines, and multiple mines. Our approach was to start with a general case and then consider specific cases for comparison. A model underground uranium mine was used to provide definition of the order of magnitude of typical impacts. Then computations were made for specific mines using the best mine-specific information available for each mine. These case study results are expressed as predicted incremental radon concentration contours plotted on maps with local population data from a previous study. Finally, the effect of possible overlap of radon releases from nearby mines was studied by calculating cumulative radon concentrations for multiple mines in a region with many mines. The dispersion model, modeling assumptions, data sources, computational procedures, and results are documented in this report. 7 refs., 27 figs., 18 tabs.

  15. Modeled atmospheric radon concentrations from uranium mines

    International Nuclear Information System (INIS)

    Droppo, J.G.

    1985-04-01

    Uranium mining and milling operations result in the release of radon from numerous sources of various types and strengths. The US Environmental Protection Agency (EPA) under the Clean Air Act, is assessing the health impact of air emissions of radon from underground uranium mines. In this case, the radon emissions may impact workers and residents in the mine vicinity. To aid in this assessment, the EPA needs to know how mine releases can affect the radon concentrations at populated locations. To obtain this type of information, Pacific Northwest Laboratory used the radon emissions, release characteristics and local meterological conditions for a number of mines to model incremental radon concentrations. Long-term, average, incremental radon concentrations were computed based on the best available information on release rates, plume rise parameters, number and locations of vents, and local dispersion climatology. Calculations are made for a model mine, individual mines, and multiple mines. Our approach was to start with a general case and then consider specific cases for comparison. A model underground uranium mine was used to provide definition of the order of magnitude of typical impacts. Then computations were made for specific mines using the best mine-specific information available for each mine. These case study results are expressed as predicted incremental radon concentration contours plotted on maps with local population data from a previous study. Finally, the effect of possible overlap of radon releases from nearby mines was studied by calculating cumulative radon concentrations for multiple mines in a region with many mines. The dispersion model, modeling assumptions, data sources, computational procedures, and results are documented in this report. 7 refs., 27 figs., 18 tabs

  16. Working towards residential Radon survey in South America

    International Nuclear Information System (INIS)

    Zielinski, Jan M.; University of Ottawa, ON; Canoba, Analia C.; Shilnikova, Natalia S.; Veiga, Lene H. S.

    2008-01-01

    Information about residential radon levels in low and middle income countries is very sparse. In response to the World Health Organization initiative in the International Radon Project, we propose a research project that will address this knowledge gap in South America by conducting a residential radon survey. Following initial in vitro and in vivo studies of radon and studies of uranium miners exposed to radon, over twenty large case-control studies of lung cancer risk from exposure to residential radon have been completed worldwide by year 2004. Recently pooled data from these individual studies have been analyzed. These collaborative analyses of the indoor studies in Europe, North America, and China provide strong direct evidence that radon is causing a substantial number of lung cancers in the general population. To reduce radon lung cancer risk, national authorities must have methods and tools based on solid scientific evidence to develop sound public health policies. We propose to conduct a survey in ten South American countries using the distribution and analysis of passive alpha tracking detectors in houses selected at random in pre-selected cities in each participating country. We also present an approach to estimate the cost of carrying out such a survey and the radon laboratory infrastructure needed. The results of the proposed survey will allow to conduct assessment of the exposure to residential radon in the populations of South American countries and to assess the health impact of this exposure. The results of the project will also help national health authorities in developing national residential radon action levels and regulations, as well as provide public health guidance for radon awareness and mitigation. (author)

  17. Characterization of radon levels in indoor air

    International Nuclear Information System (INIS)

    George, A.C.

    1982-01-01

    The purpose is to describe the different types of monitoring and sampling techniques that can determine the radiation burden of the general public from radon and its decay products. This is accomplished by measuring the range and distribution of radon and radon decay products through broad surveys using simple and convenient integrating monitoring instruments. For in-depth studies of the behavior of radon decay products and calculation of the radiation dose to the lung, fewer and more intensive and complex measurements of the particle size distribution and respiratory deposition of the radon decay products are required. For diagnostic purposes, the paper describes measurement techniques of the sources and exhalation rate of radon and the air exchange inside buildings. Measurement results form several studies conducted in ordinary buildings in different geographical areas of the United States, using the described monitoring techniques, indicate that the occupants of these buildings are exposed to radon and radon decay product concentrations, varying by as much as a factor of 20

  18. Membrane barriers for radon gas flow restrictions

    International Nuclear Information System (INIS)

    Archibald, J.F.

    1984-08-01

    Research was performed to assess the feasibility of barrier membrane substances, for use within mining or associated high risk environments, in restricting the diffusion transport of radon gas quantities. Specific tests were conducted to determine permeability parameters of a variety of membrane materials with reference to radon flow capabilities. Tests were conducted both within laboratory and in-situ emanation environments where concentrations and diffusion flows of radon gas were known to exist. Equilibrium radon gas concentrations were monitored in initially radon-free chambers adjacent to gas sources, but separated by specified membrane substances. Membrane barrier effectiveness was demonstrated to result in reduced emanation concentrations of radon gas within the sampling chamber atmosphere. Minimum gas concentrations were evidenced where the barrier membrane material was shown to exhibit lowest radon permeability characteristics

  19. QA/QC For Radon Concentration Measurement With Charcoal Canister

    International Nuclear Information System (INIS)

    Pantelic, G.; Zivanovic, M.; Rajacic, M.; Krneta Nikolic, J.; Todorovic, D.

    2015-01-01

    The primary concern of any measuring of radon or radon progeny must be the quality of the results. A good quality assurance program, when properly designed and diligently followed, ensures that laboratory staff will be able to produce the type and quality of measurement results which is needed and expected. Active charcoal detectors are used for testing the concentration of radon in dwellings. The method of measurement is based on radon adsorption on coal and measurement of gamma radiation of radon daughters. Upon closing the detectors, the measurement was carried out after achieving the equilibrium between radon and its daughters (at least 3 hours) using NaI or HPGe detector. Radon concentrations as well as measurement uncertainties were calculated according to US EPA protocol 520/5-87-005. Detectors used for the measurements were calibrated by 226Ra standard of known activity in the same geometry. Standard and background canisters are used for QA and QC, as well as for the calibration of the measurement equipment. Standard canister is a sealed canister with the same matrix and geometry as the canisters used for measurements, but with the known activity of radon. Background canister is a regular radon measurement canister, which has never been exposed. The detector background and detector efficiency are measured to ascertain whether they are within the warning and acceptance limits. (author).

  20. AN INTERNATIONAL COOPERATION BY USING AN ALL-ENCOMPASSING PASSIVE RADON MONITOR.

    Science.gov (United States)

    Tommasino, L; Chen, J; Falcomer, R; Janik, M; Kanda, R; DeFelice, F; Cardellini, F; Trevisi, R; Leonardi, F; Magnoni, M; Chiaberto, E; Agnesod, G; Ragani, M Faure; Espinosa, G; Golzarri, J; Kozak, K; Mazur, J

    2017-11-01

    The recently developed radon film-badge makes it possible to measure radon indoors, in soil, in water and/or in aqueous media (e.g. mud). As a result of its wide response linearity, this monitor has been successfully used to measure radon in-water with concentrations from 10 to ~10 000 Bq/L. By exploiting the unique characteristics of this badge, a mini-survey has been carried out by Health Canada in which radon in water was measured from 12 private wells, as well as in tap water originating from the Ottawa River. Due to the widespread interest of different laboratories in using these passive monitors, laboratories were provided with plastic films to construct their own badges by using in-house CR-39 detectors. Monitors were then irradiated by a known radon concentration at the National Institute of Radiation Metrology (ENEA)'s radon chamber and sent back to each laboratory for processing and counting. Even though these laboratories have been using different etching- and counting-procedures, the film-badge responses varied only within ~12%. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Prediction of residential radon exposure of the whole Swiss population: comparison of model-based predictions with measurement-based predictions.

    Science.gov (United States)

    Hauri, D D; Huss, A; Zimmermann, F; Kuehni, C E; Röösli, M

    2013-10-01

    Radon plays an important role for human exposure to natural sources of ionizing radiation. The aim of this article is to compare two approaches to estimate mean radon exposure in the Swiss population: model-based predictions at individual level and measurement-based predictions based on measurements aggregated at municipality level. A nationwide model was used to predict radon levels in each household and for each individual based on the corresponding tectonic unit, building age, building type, soil texture, degree of urbanization, and floor. Measurement-based predictions were carried out within a health impact assessment on residential radon and lung cancer. Mean measured radon levels were corrected for the average floor distribution and weighted with population size of each municipality. Model-based predictions yielded a mean radon exposure of the Swiss population of 84.1 Bq/m(3) . Measurement-based predictions yielded an average exposure of 78 Bq/m(3) . This study demonstrates that the model- and the measurement-based predictions provided similar results. The advantage of the measurement-based approach is its simplicity, which is sufficient for assessing exposure distribution in a population. The model-based approach allows predicting radon levels at specific sites, which is needed in an epidemiological study, and the results do not depend on how the measurement sites have been selected. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Metrology of radon and thoron concentrations

    International Nuclear Information System (INIS)

    Durcik, M; Vicanova, M.

    1998-01-01

    The alpha spectrometry measurements of radon (radon-222) and thoron (radon-220) concentrations by ionisation chamber, used only in laboratory conditions are described in this paper. For the measurements of radon and thoron in dwellings and work areas was proposed diffusion double chamber detector with track detector. The described dosimeter is very useful for routine measurement and would be applied in measuring of radon and thoron concentrations in caves and dwellings. Big disadvantage of the dosimeter is small holes in cover and it could not be used in dusty areas. From previous measurements of the equilibrium equivalent thoron concentrations by semiconductor detector the measured values ranged from 0.1 to 5.6 Bq m -3 in the Slovak kindergartens were obtained

  3. Plastic-bag radon gas monitor and survey results

    International Nuclear Information System (INIS)

    Torri, G.

    1990-01-01

    The Plastic-bag radon monitor used in the Italian National Survey is described. The choice of this radon gas sampler has been determined by the peculiarity of the italian environmental monitoring program, which is carried out by several different regional laboratories. Results obtained in the past using this radon monitoring device are also reported. (author). 8 refs, 7 figs

  4. Field testing of asphalt-emulsion radon-barrier system

    International Nuclear Information System (INIS)

    Hartley, J.N.; Freeman, H.D.; Baker, E.G.; Elmore, M.R.; Nelson, D.A.; Voss, C.F.; Koehmstedt, P.L.

    1981-09-01

    Three years of laboratory and field testing have demonstrated that asphalt emulsion seals are effective radon diffusion barriers. Both laboratory and field tests in 1979, 1980 and 1981 have shown that an asphalt emulsion seal can reduce radon fluxes by greater than 99.9%. The effective diffusion coefficient for the various asphalt emulsion admix seals averages about 10 -6 cm 2 /s. The 1981 joint field test is a culmination of all the technology developed to date for asphalt emulsion radon barrier systems. Preliminary results of this field test and the results of the 1980 field test are presented. 18 figures, 6 tables

  5. Development of apparatus and procedures for evaluating radon-resistant construction materials

    International Nuclear Information System (INIS)

    Pugh, T.D.; Greenfield, M.B.; MacKenzie, J.; Meijer, R.J. de

    1992-01-01

    Laboratory facilities and apparatus have been constructed to measure radon exhalation from, and radon permeability through, various construction materials. This phase of the project has focused on development of test apparatus and evaluation of instrumentation. Results indicate significant spatial variability in the radon permeability of polyethylene, even when all test samples were selected from the same roll of material, and when no visible differentiation could be made regarding sample quality. Implications for code enforcement are described, and recommendations are offered for refinement of equipment and the measurement process, prioritization of future materials testing, and specific building code provisions, based on our results

  6. Measurement of radon exhalation rate and soil gas radon concentration in areas of southern Punjab (Pakistan)

    International Nuclear Information System (INIS)

    Mujahid, S. A.; Hussain, S.; Ramzan, M.

    2010-01-01

    Plastic track detectors were used to measure the radon concentration and exhalation rate from the soil samples. The samples were collected from areas of southern Punjab (Pakistan). In a laboratory experiment, passive alpha dosemeters were installed inside cylindrical bottles containing the soil samples. The radon concentrations and the radon exhalation rate were found in the ranges of 34±7 to 260±42 Bq m -3 and 38±8 to 288±46 mBq m -2 h -1 , respectively. The on-site measurements of radon in the soil gas were also carried out in these areas using a scintillation alpha counter. The concentration of radon in the soil gas was found in the range of 423±82-3565±438 Bq m -3 . (authors)

  7. Radon Concentrations in Drinking Water in Beijing City, China and Contribution to Radiation Dose

    Science.gov (United States)

    Wu, Yun-Yun; Ma, Yong-Zhong; Cui, Hong-Xing; Liu, Jian-Xiang; Sun, Ya-Ru; Shang, Bing; Su, Xu

    2014-01-01

    222Rn concentrations in drinking water samples from Beijing City, China, were determined based on a simple method for the continuous monitoring of radon using a radon-in-air monitor coupled to an air-water exchanger. A total of 89 water samples were sampled and analyzed for their 222Rn content. The observed radon levels ranged from detection limit up to 49 Bq/L. The calculated arithmetic and geometric means of radon concentrations in all measured samples were equal to 5.87 and 4.63 Bq/L, respectively. The average annual effective dose from ingestion of radon in drinking water was 2.78 μSv, and that of inhalation of water-borne radon was 28.5 μSv. It is concluded that it is not the ingestion of waterborne radon, but inhalation of the radon escaping from water that is a substantial part of the radiological hazard. Radon in water is a big concern for public health, especially for consumers who directly use well water with very high radon concentration. PMID:25350007

  8. Radon Concentrations in Drinking Water in Beijing City, China and Contribution to Radiation Dose

    Directory of Open Access Journals (Sweden)

    Yun-Yun Wu

    2014-10-01

    Full Text Available 222Rn concentrations in drinking water samples from Beijing City, China, were determined based on a simple method for the continuous monitoring of radon using a radon-in-air monitor coupled to an air-water exchanger. A total of 89 water samples were sampled and analyzed for their 222Rn content. The observed radon levels ranged from detection limit up to 49 Bq/L. The calculated arithmetic and geometric means of radon concentrations in all measured samples were equal to 5.87 and 4.63 Bq/L, respectively. The average annual effective dose from ingestion of radon in drinking water was 2.78 μSv, and that of inhalation of water-borne radon was 28.5 μSv. It is concluded that it is not the ingestion of waterborne radon, but inhalation of the radon escaping from water that is a substantial part of the radiological hazard. Radon in water is a big concern for public health, especially for consumers who directly use well water with very high radon concentration.

  9. Comparison of passive and active radon measurement methods for personal occupational dose assessment

    Directory of Open Access Journals (Sweden)

    Hasanzadeh Elham

    2016-01-01

    Full Text Available To compare the performance of the active short-term and passive long-term radon measurement methods, a study was carried out in several closed spaces, including a uranium mine in Iran. For the passive method, solid-state nuclear track detectors based on Lexan polycarbonate were utilized, for the active method, AlphaGUARD. The study focused on the correlation between the results obtained for estimating the average indoor radon concentrations and consequent personal occupational doses in various working places. The repeatability of each method was investigated, too. In addition, it was shown that the radon concentrations in different stations of the continually ventilated uranium mine were comparable to the ground floor laboratories or storage rooms (without continual ventilation and lower than underground laboratories.

  10. Methods of radon measurement and devices

    International Nuclear Information System (INIS)

    Miles, J.

    2004-01-01

    The following topics and instrumentation are discussed: The quantity to be measured; Active measurement methods (scintillation cells, ionisation chambers, electrostatic collection of decay products); Passive measurement methods (charcoal detectors; electret ion chambers; etched track detectors); and Detector considerations for large-scale surveys ('always on' or 'switchable' detectors?; response to radon-220; avoidance of electrostatic effects; quality assurance for passive radon detectors; quality control within the laboratory; external quality assurance; detectors need to be easily deliverable). It is concluded that the ideal detector for large scale surveys of radon in houses is a small, closed detector in a conducting holder which excludes radon-220, supported by rigorous quality assurance procedures. (P.A.)

  11. Influence of cover defects on the attenuation of radon with earthen covers

    International Nuclear Information System (INIS)

    Kalkwarf, D.R.; Mayer, D.W.

    1983-11-01

    Experimental and theoretical evaluations of radon flux through laboratory-scale defective soil columns are presented together with a survey of literature on the formation and prevention of defects in soil covers. This report focuses on air-filled, centimeter-scale defects that are most probable in earthen covers for attenuating radon emission from uranium-mill tailings. Examples include shirnkage and erosion cracks, erosion piping, animal burrows and air channels formed by the biodegradation of vegetation roots. Calculations based on mathematical models indicate that collections of defects which could increase the radon flux from an earthen cover by a factor of two would be easily detected by visual inspection. However, these models ignore air-turbulence in the defect and drying of the soil around the defect. Laboratory measurements showed that turbulent diffusion of radon occurred through defects as narrow as 0.3 cm when subjected to a transverse air velocity of 1 to 6 miles per hour at the surface. Both turbulence and more-rapid drying of soil can accelerate radon flux to the cover surface. Consequently, recommended methods to inhibit defect formation should be applied. 29 references, 3 figures, 5 tables

  12. Nuclear literacy in light of radon

    International Nuclear Information System (INIS)

    Lazar, I.; Cziegler, I.

    2000-01-01

    Since 1992 the RAD Lauder Laboratory has carried out a survey of indoor radon levels all over Hungary. The co-workers of RAD Lauder were pupils and teachers in local schools. More than 50,000 people have taken the survey and received detailed information on the radon levels in their homes. (authors)

  13. Radiation hazard due to radon in indoor air

    International Nuclear Information System (INIS)

    Keller, G.

    1987-01-01

    Inhalation of the noble gas radon and its short-lived daughter products present in normal room air causes a considerable increase of the mean natural radiation exposure of the population. As there is an uncontested relationship between lung dose and cancer risk, measures should be taken to guarantee that the radon concentrations in room air do at least not reach maxima. The most simple measure is frequent, brief, good ventilation. Very high radon concentrations are measured in houses where radon pentrates direct from the soil into buildings. For this case, radon-tight insulation of the building from the soil is recommended. A forced ventilation system with heat recovery, installed by experts, has shown to be very successful in radon reduction in 'problematic' houses. (orig.) [de

  14. The use of radon as an earthquake precursor

    International Nuclear Information System (INIS)

    Ramola, R.C.; Singh, M.; Sandhu, A.S.; Singh, S.; Virk, H.S.

    1990-01-01

    Radon monitoring for earthquake prediction is part of an integral approach since the discovery of coherent and time anomalous radon concentrations prior to, during and after the 1966 Tashkent earthquake. In this paper some studies of groundwater and soil gas radon content in relation to earthquake activities are reviewed. Laboratory experiments and the development of groundwater and soil gas radon monitoring systems are described. In addition, radon monitoring studies conducted at the Guru Nanak Dev University Campus since 1986 are presented in detail. During these studies some anomalous changes in radon concentration were recorded before earthquakes occurred in the region. The anomalous radon increases are independent of meteorological conditions and appear to be caused by strain changes, which precede the earthquake. Anomalous changes in radon concentration before an earthquake suggest that radon monitoring can serve as an additional technique in the earthquake prediction programme in India. (author)

  15. Assessment of radon exposure in Austria based on geology and settlement

    International Nuclear Information System (INIS)

    Gruber, Valeria; Seidel, Claudia

    2008-01-01

    are used as input for geo-statistical modelling. Based on the results an applied assessment and distribution of radon exposure of the population can be carried out and used for radiation protection measures and precautions like regulations, health studies, land use planning and urban development. First exposure assessments and distributions complete this paper. (author)

  16. How well do radon mitigation strategies work?

    International Nuclear Information System (INIS)

    Matson, N.

    1992-01-01

    Naturally occurring radon in homes can't be completely avoided, but it can be minimized. Indoor air quality researchers compared results of six popular ways to mitigate radon in houses in the Spokane River Valley and New Jersey. Over the course of the past decade, Americans have become aware of the health hazards from radon, a naturally occurring gas that can enter a home through a variety of pathways from the surrounding terrain. Recent research carried out at Lawrence Berkeley Laboratory (LBL) and elsewhere suggests that radon mitigation is feasible but requires long-term monitoring to ensure lasting effectiveness. These studies compare the selection, installation, and performance evaluations of several common radon mitigation strategies

  17. Operating instructions for LBL radon measurement facilities

    International Nuclear Information System (INIS)

    Ingersoll, J.G.

    1980-06-01

    This manual is intended for users of the radon-measuring facilities of the Radon Project of the Building Ventilation and Indoor Air Quality Program at Lawrence Berkeley Laboratory. The manual comprises three parts. Part 1 sets out the steps involved in collecting, transferring, and counting radon. Part 2 describes the calibration of the transfer system and of the Lucas cells in the counting system. Part 3 outlines the maintenance procedures for the facility

  18. Effect of fresh air ventilation on indoor radon concentration

    International Nuclear Information System (INIS)

    Sun Hao; Wu Jianhua; Fu Shi

    2012-01-01

    The radon concentration of laboratory for radon simulation (LRS) was measured by the RAD7 radon monitor, and the effect of the different fresh air ventilations on indoor radon concentration was studied and analyzed. The indoor radon concentration of LRS can be accumulated up to 2000 Bq/m 3 and the average radon exhalation rate of the LRS is 14.5 Bq · m -2 . h -1 . Furthermore, when the fresh air enters into the LRS continuously, the indoor radon concentration decreases exponentially with the increase of time. The equilibrium radon concentration and equilibrium time of LRS decrease exponentially with the increase of the rate of fresh air ventilation. In addition, the indoor radon concentration increases by accumulation with the decrease of the rate of fresh air ventilation. (authors)

  19. Influence of moisture content on radon diffusion in soil

    International Nuclear Information System (INIS)

    Singh, M.; Ramola, R.C.; Singh, S.; Virk, H.S.

    1990-01-01

    Radon diffusion from soil has been studied as a function of the moisture content of the soil. A few simple experiments showed that up to a certain moisture content the radon diffusion increased with increasing moisture. A sharp rise in radon concentration occurred as the moisture was increased from the completely dry state to 13% water by weight. The radon flux was measured for columns of dry, moist and water saturated soil. The highest flux came from the column filled with moist soil. Water saturated soil gave the lowest flux because of the much lower diffusion coefficient of radon through water. (author)

  20. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample.

    Science.gov (United States)

    Lee, Kil Yong; Burnett, William C

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 °C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods.

  1. Determination of air-loop volume and radon partition coefficient for measuring radon in water sample

    International Nuclear Information System (INIS)

    Kil Yong Lee; Burnett, W.C.

    2013-01-01

    A simple method for the direct determination of the air-loop volume in a RAD7 system as well as the radon partition coefficient was developed allowing for an accurate measurement of the radon activity in any type of water. The air-loop volume may be measured directly using an external radon source and an empty bottle with a precisely measured volume. The partition coefficient and activity of radon in the water sample may then be determined via the RAD7 using the determined air-loop volume. Activity ratios instead of absolute activities were used to measure the air-loop volume and the radon partition coefficient. In order to verify this approach, we measured the radon partition coefficient in deionized water in the temperature range of 10-30 deg C and compared the values to those calculated from the well-known Weigel equation. The results were within 5 % variance throughout the temperature range. We also applied the approach for measurement of the radon partition coefficient in synthetic saline water (0-75 ppt salinity) as well as tap water. The radon activity of the tap water sample was determined by this method as well as the standard RAD-H 2 O and BigBottle RAD-H 2 O. The results have shown good agreement between this method and the standard methods. (author)

  2. Quality assurance for radon measurements in Germany

    International Nuclear Information System (INIS)

    Beck, T.R.; Buchroeder, H.; Foerster, E.; Schmidt, V.

    2005-01-01

    Full text: Radiation protection regarding work activities at workplaces with naturally occurring radiation has been regulated in the German Radiation Protection Ordinance. Regulations refer only to workplaces where the presence of natural radiation leads to a significant increase in the exposure of workers. These workplaces were identified in the following working areas with enhanced exposures to radon-222: underground mines, including visitor mines and show caves; radon-spas and galleries; water supply and distribution industries. Presently, regulations are being initiated by the German government to limit the exposures to radon in homes. For radon measurements at workplaces passive radon devices for individual monitoring as well as active measuring systems for workplace monitoring can be used. However, passive radon devices are preferred for radon measurements in homes because of low costs and availability in large quantities. To assure the quality of radon measurements the German Federal Office for Radiation Protection (BfS) has established annual interlaboratory comparisons for passive radon devices. The comparisons are carried out in the BfS radon calibration laboratory accredited by the German Calibration Service. Passive radon devices which use solid state track detectors, electrets or activated charcoal can be submitted. Approved radon services which offer radon measurements to determine radon exposure in homes and at workplaces have to pass the comparisons successfully. (author)

  3. Indoor radon concentration and outdoor/indoor pressure difference correlation

    International Nuclear Information System (INIS)

    Cechak, T.; Fronka, A.; Moucka, L.

    2004-01-01

    In the current approach to the radon issue, the radon risk for people living in a building is estimated based on the average indoor radon concentration. Short-term measurements as usually applied fail to reflect the wide range of radon variations arising from ventilation, radon supply and, in particular, human activities in the building. For this reason, efforts are made to find a new approach to the assessment of the quality of a building as a radon barrier, independent of the weather conditions and residential habits. A simple model of radon volume activity entering the building at a constant rate and simultaneously ventilated at a constant rate is applicable to this task. The rate of radon ingress can be regarded as a parameter making it possible to quantify the leakage of structures provided the barrier against the radon in a soil gas. The ventilation rate, on the other hand, characterizes the leakage of the whole building envelope at a given outdoor/indoor pressure difference. A unique measuring technique called the blower door exists whereby a defined pressure difference between the indoor and outdoor atmosphere can be established. Under such conditions both the ventilation rate and the rate of radon ingress can be measured and expressed as a function of the pressure difference. An analysis of the model of a room with a constant ventilation and constant radon supply is presented and the relationship between radon supply and ventilation rate can be assumed. Some experimental results show how the model can be utilized. The real indoor-outdoor air pressure differences, the indoor-soil air pressure differences, and some effects of different ventilation regimes are given. Other experiments, which have been done by using the blower door method, illustrate the possible effects and some restrictions for a routine application are discussed

  4. The Radon from environment to man

    International Nuclear Information System (INIS)

    Metivier, H.; Robe, M.Ch.

    1998-01-01

    The radon inhalation is the principal source of populations irradiation. At the dawn of a new regulation, the best specialists of the radon in France, give the different properties of this gas in order to allow to the non advertised populations to appreciate the risks. This work explains the origin, the formation of this radioactive gas, how is it detected, its behaviour in atmosphere and habitations. A cartography of the radon concentration is given where it is possible to see the differences between the regions. The question of risks is also approached even if it difficult to estimate because it comes from extrapolation. Finally, the reader will find simple methods to reduce irradiation by radon in our habitations. (N.C.)

  5. Prediction of indoor radon concentration based on residence location and construction

    International Nuclear Information System (INIS)

    Maekelaeinen, I.; Voutilainen, A.; Castren, O.

    1992-01-01

    We have constructed a model for assessing indoor radon concentrations in houses where measurements cannot be performed. It has been used in an epidemiological study and to determine the radon potential of new building sites. The model is based on data from about 10,000 buildings. Integrated radon measurements were made during the cold season in all the houses; their geographic coordinates were also known. The 2-mo measurement results were corrected to annual average concentrations. Construction data were collected from questionnaires completed by residents; geological data were determined from geological maps. Data were classified according to geographical, geological, and construction factors. In order to describe different radon production levels, the country was divided into four zones. We assumed that the factors were multiplicative, and a linear concentration-prediction model was used. The most significant factor in determining radon concentration was the geographical region, followed by soil type, year of construction, and type of foundation. The predicted indoor radon concentrations given by the model varied from 50 to 440 Bq m -3 . The lower figure represents a house with a basement, built in the 1950s on clay soil, in the region with the lowest radon concentration levels. The higher value represents a house with a concrete slab in contact with the ground, built in the 1980s, on gravel, in the region with the highest average radon concentration

  6. Application of CR-39 to radon measurement

    International Nuclear Information System (INIS)

    Miyake, Hiroshi

    1988-01-01

    CR-39, an ally diglycol carbonate, has recently come into wider use as material for solid-state track detector. Etching with NaOH or KOH solution allow CR-39 to develop extremely clear etch pits attributed to alpha rays. The most widely used method for measuring radon concentration employs a plastic cup with a solid-state track detector mounted at its bottom to detect alpha rays resulting from radon or its daughters that disintegrate within or on the wall of the cup. Simple in mechanism and low in cost, this method is suitable for such a case where the radon concentration distribution over a wide area has to be measured by using a large number of devices. The concentration of radon alone can be measured with the aid of a filter attached to the mouth of the cup to remove the daughters of radon and thoron. The simplest and most effective way of improving the sensitivity of a solid-state track detector for radon concentration measurement is to electrostatically collect daughters resulting from decay of radon onto the surface of the detector. Another method widely used to determine the radon concentration is to measure the concentration of the radon daughters instead of direct measurement of the concentration of radon itself. (Nogami, K.)

  7. Creating Geologically Based Radon Potential Maps for Kentucky

    Science.gov (United States)

    Overfield, B.; Hahn, E.; Wiggins, A.; Andrews, W. M., Jr.

    2017-12-01

    Radon potential in the United States, Kentucky in particular, has historically been communicated using a single hazard level for each county; however, physical phenomena are not controlled by administrative boundaries, so single-value county maps do not reflect the significant variations in radon potential in each county. A more accurate approach uses bedrock geology as a predictive tool. A team of nurses, health educators, statisticians, and geologists partnered to create 120 county maps showing spatial variations in radon potential by intersecting residential radon test kit results (N = 60,000) with a statewide 1:24,000-scale bedrock geology coverage to determine statistically valid radon-potential estimates for each geologic unit. Maps using geology as a predictive tool for radon potential are inherently more detailed than single-value county maps. This mapping project revealed that areas in central and south-central Kentucky with the highest radon potential are underlain by shales and karstic limestones.

  8. Measurements of radon in soil gas

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine Nicolosi; Schelin, Hugo R.; Barbosa, Laercio; Sadula, Tatyana; Matsuzaki, Cristiana A.

    2009-01-01

    Full text: After the decades of systematic and numerous studies performed at different countries of the World, it has been concluded that radon as well as its progeny is the main cause of lung cancer. It is well known that more than 50% of the effective annual radiation dose received by a human being is related to the radon and its progenies. Among the principle mechanisms that bring the radon inside the dwelling is the soil exhalation as well as exhalation and release from the water. Radon concentration in the soil and its transport (emanation, diffusion, advection and adsorption) to the surface depends on different physical, geological and ambient parameters such as the geology of the area, geochemical composition of the soil, its porosity and permeability, grain size, soil humidity, bottom sediments and inputs from streams, temperature, atmospheric pressure, etc. Since the main part of indoor radon originates in the soil, the measurements of radon concentration in soil gas have to be considered as an important tool and indicator of probable high levels of radon inside the dwellings. Present work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222 Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. The equipment was adjusted with air flow of 0

  9. Cost and effectiveness of radon barrier systems

    International Nuclear Information System (INIS)

    Baker, E.G.; Freeman, H.D.; Hartley, J.N.; Gee, G.W.

    1982-12-01

    Earthen, asphalt, and multilayer radon barrier systems can all provide reduction in the amount of radon gas released from uranium mill tailings. Pacific Northwest Laboratory field tested all three types of covers at Grand Junction, Colorado during the summer of 1981. All nine individual radon barrier systems tested currently meet the EPA standard for radon flux of 20 pCi m - 2 s - 1 . The cost of the asphalt and 3m earthen covers were about the same at the field test. Multilayer covers were significantly more costly. Cost estimates for three high priority western sites indicate 3m of earthen cover is the least costly radon barrier when earthen material is available at or near the disposal site. If earthen material must be imported more than 8 to 10 km asphalt and possibly multilayer radon barriers can be cost effective

  10. Interaction of radon progeny with atmospheric aerosols

    International Nuclear Information System (INIS)

    Morawska, Lidia

    1994-01-01

    The radiological health hazard due to the airborne radon progeny depends on three factors (i) radon concentration in the air, (ii) radon progeny concentration, and (iii) active particle size distribution. Conclusions as to the health hazard cannot be drawn without full understanding of the interaction mechanisms between radon progeny and atmospheric aerosols. The aim of this work was to study the interaction mechanisms between radon progeny, natural environmental aerosols and environmental tobacco smoke (ETS). The experiments were performed under controlled laboratory conditions of radon concentration (1.85 and 3.70 Bq m -3 ), relative humidity (35, 50, 75 and 95%) and ETS generation. The size distribution of radioactivity carrying aerosols was measured using a wire screen diffusion battery system and size distribution of all airborne aerosols using a differential mobility particle sizer. The paper presents and discusses the results of activity size distribution and radon progeny concentration measurements for different environmental conditions. 7 refs., 2 tabs

  11. Contribution to the improvement of radon risk evaluation in Spain

    International Nuclear Information System (INIS)

    Ortega, X.; Vargas, A.

    2002-01-01

    The 96/29/Euratom Directive aims to introduce radon regulation at working places in European Countries. Within the framework, the Spanish Nuclear Regulatory Body, the Nuclear Safety Council (CSN), is interested in obtaining a reliable level of quality for radon measurements in Spain. The radon laboratory group at the Institute of Energetic Techniques of the Technical University of Catalonia in Barcelona (INTE) has been commissioned to adequate its radon chamber for testing radon instruments using standards as IEC 61577 and ISO 13466

  12. Alpha scintillation radon counting

    International Nuclear Information System (INIS)

    Lucas, H.F. Jr.

    1977-01-01

    Radon counting chambers which utilize the alpha-scintillation properties of silver activated zinc sulfide are simple to construct, have a high efficiency, and, with proper design, may be relatively insensitive to variations in the pressure or purity of the counter filling. Chambers which were constructed from glass, metal, or plastic in a wide variety of shapes and sizes were evaluated for the accuracy and the precision of the radon counting. The principles affecting the alpha-scintillation radon counting chamber design and an analytic system suitable for a large scale study of the 222 Rn and 226 Ra content of either air or other environmental samples are described. Particular note is taken of those factors which affect the accuracy and the precision of the method for monitoring radioactivity around uranium mines

  13. Radon-222 related influence on ambient gamma dose.

    Science.gov (United States)

    Melintescu, A; Chambers, S D; Crawford, J; Williams, A G; Zorila, B; Galeriu, D

    2018-04-03

    Ambient gamma dose, radon, and rainfall have been monitored in southern Bucharest, Romania, from 2010 to 2016. The seasonal cycle of background ambient gamma dose peaked between July and October (100-105 nSv h -1 ), with minimum values in February (75-80 nSv h -1 ), the time of maximum snow cover. Based on 10 m a.g.l. radon concentrations, the ambient gamma dose increased by around 1 nSv h -1 for every 5 Bq m -3 increase in radon. Radon variability attributable to diurnal changes in atmospheric mixing contributed less than 15 nSv h -1 to the overall variability in ambient gamma dose, a factor of 4 more than synoptic timescale changes in air mass fetch. By contrast, precipitation-related enhancements of the ambient gamma dose were 15-80 nSv h -1 . To facilitate routine analysis, and account in part for occasional equipment failure, an automated method for identifying precipitation spikes in the ambient gamma dose was developed. Lastly, a simple model for predicting rainfall-related enhancement of the ambient gamma dose is tested against rainfall observations from events of contrasting duration and intensity. Results are also compared with those from previously published models of simple and complex formulation. Generally, the model performed very well. When simulations underestimated observations the absolute difference was typically less than the natural variability in ambient gamma dose arising from atmospheric mixing influences. Consequently, combined use of the automated event detection method and the simple model of this study could enable the ambient gamma dose "attention limit" (which indicates a potential radiological emergency) to be reduced from 200 to 400% above background to 25-50%. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. LIFETIME LUNG CANCER RISKS ASSOCIATED WITH INDOOR RADON EXPOSURE BASED ON VARIOUS RADON RISK MODELS FOR CANADIAN POPULATION.

    Science.gov (United States)

    Chen, Jing

    2017-04-01

    This study calculates and compares the lifetime lung cancer risks associated with indoor radon exposure based on well-known risk models in the literature; two risk models are from joint studies among miners and the other three models were developed from pooling studies on residential radon exposure from China, Europe and North America respectively. The aim of this article is to make clear that the various models are mathematical descriptions of epidemiologically observed real risks in different environmental settings. The risk from exposure to indoor radon is real and it is normal that variations could exist among different risk models even when they were applied to the same dataset. The results show that lifetime risk estimates vary significantly between the various risk models considered here: the model based on the European residential data provides the lowest risk estimates, while models based on the European miners and Chinese residential pooling with complete dosimetry give the highest values. The lifetime risk estimates based on the EPA/BEIR-VI model lie within this range and agree reasonably well with the averages of risk estimates from the five risk models considered in this study. © Crown copyright 2016.

  15. Rapid determination of radon daughter concentrations

    International Nuclear Information System (INIS)

    Bigu, J.

    1990-08-01

    A technical evaluation of four radon 222 progeny measuring instruments has been conducted. The evaluation has been carried out under laboratory controlled conditions and at several locations in an underground uranium mine. The laboratory evaluation consisted of a thorough study of the behaviour and performance of the instruments under a wide variety of environmental conditions such as radon 222 gas concentration, radon 222 progeny concentration, temperature, relative humidity, aerosol concentration, and gamma-field exposure. The four instruments tested were: the Pylon WL-1000C, the MDA IWLM-811, the MIMIL IIM, and the EDA WLM-30. The readings of the instruments were compared with a widely accepted radon 222 progeny concentration measuring method, namely, the Thomas-Tsivoglou method. Two variables affected two instruments significantly, namely, under high aerosol concentration conditions, one of the instruments (EDA WLM-30) ceased to operate because of filter loading. The other variable was gamma-field exposure which affected another instrument (MDA-811) adversely. The instruments were rated according to several criteria. The overall best performer was the MIMIL IIM, although other instruments also fared quite well under a variety of experimental conditions

  16. Use of static and ac field techniques for measuring mobility and charge lifetimes of radon progeny with a simple device

    International Nuclear Information System (INIS)

    Sapra, B.K.; Mayya, Y.S.

    1998-01-01

    A simple device, based on a modification of the scintillation cell, has been developed for the measurement of radon daughter mobility and charge lifetimes by employing AC and static electric fields. It has a central electrode coated with ZnS and the scintillations are recorded by a PMT unit. The coating is made on the wire, instead of on the inner walls, to improve the relative response of the device with respect to the zero field situation. Radon is drawn into the cell by evacuation techniques. Theoretical formulae, relating the observed count rates to the system parameters and progeny mobilities and charge lifetimes, have been derived under zero field, static and AC field situations. Measurements indicate that the device has very low leak rate (T 1/2 ∼38 days) and the initial environment if maintained for long time. Results of experiments carried out with static and AC fields in most air yielded 218 Po mobilities (1.89 cm 2 /V/s) and charge lifetimes (0.08s) are comparable to those reported in the literature. This demonstrates the feasibility of this technique for future studies with different trace gases. A major advantage of this device as opposed to the conventional spectrometric methods is its simplicity. (author)

  17. Is radon 222 an appropriate tracer for the study of seismic precursors?

    International Nuclear Information System (INIS)

    Richon, P.; Heritier, T.; Sebe, O.; Maffat, I.; Holtzappfel, T.; Le Hesran, E.; Geber, O.; Ulziibat, M.; Demberel, S.; Oyun-Erdene, M.; Bilguun, M.

    2015-01-01

    Radon 222 is a natural radionuclide that can be measured in air, water, and soil in very, very small quantities. Experiments performed in laboratories have shown that a local strain on a rock has an impact on the mobility of the radon gas and as local strains increase with the approach of an earthquake, it is considered that radon abnormal measurements may help predicting earthquakes. The first stage to extrapolate laboratory results to large-scale application is to master the metrology of the radon gas. A campaign of measurements achieved in Mongolia on the Emeelt site has allowed an optimization of radon metrology and of the positioning of the probes. Preliminary results have shown that abnormal values of radon concentrations that are not correlated with local meteorology, appear a few days before local seismic activity resumes

  18. Uranium and radon surveys in western Himalaya

    International Nuclear Information System (INIS)

    Virk, H.S.

    1997-01-01

    The water samples from mountain springs, streams and river systems in the western Himalaya were collected and analysed in the laboratory for uranium and radon contents. It is observed that the Himalayan river system is conspicuous by its high dissolved uranium and radium concentration. The water samples contain from 0.89 ppb to 63.4 ppb of uranium and from 34 Bq/I to 364 Bq/I of radon. The radon emanation in soil is measured by the track-etch method, emanometry and alpha-logger technique. The daily and long-term variation of radon was monitored in some mineralized zones of Himachal Pradesh (HP) state with high uranium content in the soil. The maximum values of radon are recorded in Chhinjra, Rameda, Samurkala and Kasol areas of HP. (author)

  19. Ventilation measurements as an adjunct to radon measurements in buildings

    International Nuclear Information System (INIS)

    Knutson, E.O.; Franklin, H.

    1977-01-01

    The concentration of radon in a building is a function of the radon sources within the building and of the building's ventilation characteristics. To complement its radon measurement program, HASL is currently assessing apparatus and procedures for measuring building ventilation. Results are reported from ventilation measurements made in the laboratory and in a residential building

  20. Management of the radon-related risk. Guide for local authorities. Guide for employers

    International Nuclear Information System (INIS)

    Struillou, Yves; Gupta, Olivier

    2017-01-01

    A first guide aims at being an aid to decision by specifying obligations of local authorities as owners of buildings open to public or as employers, but also at being a support for their health and social actions in terms of information on radon risk in housing. After a presentation of the risk related to radon (health risks, radon propagation, regulatory areas concerned by radon risk management in France), the report indicates the various obligations and mandatory actions for local authorities as building owner and as employer, and actions to be undertaken for existing and new buildings. Technical sheets are provided regarding radon detection, certifications, simple actions, technical diagnosis, remediation works, efficiency control of technical solutions, expert in radiation protection. The second guide aims at being an aid to decision by specifying obligations for employers in terms of management of radon-related risk to which some workers might be exposed, and at providing some good practice recommendations. After a presentation of the risk related to radon (health risks, radon propagation, regulatory areas concerned by radon risk management in France), the report addresses how to organise the radon-related risk management, how to measure radon in work places, how to interpret results and which actions to undertake. Technical sheets are provided regarding radon detection, certifications, simple actions, technical diagnosis, remediation works, efficiency control of technical solutions, expert in radiation protection

  1. Controlled study of the evolution of radon and its decay products in radioactive mine environments

    International Nuclear Information System (INIS)

    Calizaya A, F.

    1985-01-01

    This thesis discusses three aspects related to radon emissions and control of radon decay products in mine environments: (1) measurement of the effects of environmental parameters on radiation levels, (2) analysis of the data using ordinary linear regression and transfer function models and (3) prediction of the concentration of radioactive contaminants in the mine air. In-mine and laboratory experiments were conducted to develop the research data. In mine tests were conducted in a bulkhead isolated mine drift containing low grade uranium ore at the Colorado School of Mines, Experimental Mine with the US Bureau of Mines - Spokane Research Center (USBM, SRC) micro-computer based radiation monitoring system. Parameters such as amount of ore, amount of condensation nuclei in the mine air, temperature, air velocity, and barometric pressure were studied. The laboratory tests were conducted in an air-tight radon chamber equipped with a container of the radioactive material, various monitors, and the USBM, SRC Data Acquisition System. The effect of parameters such as ore grade, particle size, rock moisture, air temperature and relative humidity on radon concentrations were measured in the laboratory. Radiation levels, together with parameters affecting these levels, were measured over a period of one year (June 1984-July 1985) both in the laboratory model and in the field

  2. Radon transport modelling: User's guide to RnMod3d

    International Nuclear Information System (INIS)

    Andersen, C.E.

    2000-08-01

    RnMod3d is a numerical computer model of soil-gas and radon transport in porous media. It can be used, for example, to study radon entry from soil into houses in response to indoor-outdoor pressure differences or changes in atmospheric pressure. It can also be used for flux calculations of radon from the soil surface or to model radon exhalation from building materials such as concrete. The finite-volume model is a technical research tool, and it cannot be used meaningfully without good understanding of the involved physical equations. Some understanding of numerical mathematics and the programming language Pascal is also required. Originally, the code was developed for internal use at Risoe only. With this guide, however, it should be possible for others to use the model. Three-dimensional steady-state or transient problems with Darcy flow of soil gas and combined generation, radioactive decay, diffusion and advection of radon can be solved. Moisture is included in the model, and partitioning of radon between air, water and soil grains (adsorption) is taken into account. Most parameters can change in time and space, and transport parameters (diffusivity and permeability) may be anisotropic. This guide includes benchmark tests based on simple problems with known solutions. RnMod3d has also been part of an international model intercomparison exercise based on more complicated problems without known solutions. All tests show that RnMod3d gives results of good quality. (au)

  3. Radon in workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.; Annanmaeki, M.; Oksanen, E.

    2000-01-01

    The EU Member States have to implement the new Basic Safety Standards Directive (BSS) by May 2000. The Title VII of the Directive applies in particular to radon in workplaces. The Member States are required to identify workplaces which may be of concern, to set up appropriate means for monitoring radon exposures in the identified workplaces and, as necessary, to apply all or part of the system of radiological protection for practices or interventions. The BSS provisions on natural radiation are based on the ICRP 1990 recommendations. These recommendations were considered in the Finnish radiation legislation already in 1992, which resulted in establishing controls on radon in all types of workplaces. In this paper issues are discussed on the practical implementation of the BSS concerning occupational exposures to radon basing on the Finnish experiences in monitoring radon in workplaces during the past seven years. (orig.) [de

  4. Metrology of the radon in air volume activity at the italian radon reference chamber

    Energy Technology Data Exchange (ETDEWEB)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M. [Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti, ENEA Centro Ricerche Casaccia Roma (Italy)

    2006-07-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of {sup 222}Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m{sup 3}. The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  5. Metrology of the radon in air volume activity at the italian radon reference chamber

    International Nuclear Information System (INIS)

    Sciocchetti, G.; Cotellessa, G.; Soldano, E.; Pagliari, M.

    2006-01-01

    The approach of the Italian National Institute of Ionising Radiations (I.N.M.R.I.-ENEA) on radon metrology has been based on a complete and integrated system which can be used to calibrate the main types of 222 Rn in air measuring instruments with international traceability. The Italian radon reference chamber is a research and calibration facility developed at the Casaccia Research Center in Roma. This facility has an inner volume of one m 3 . The wall is a cylindrical stainless steel vessel coupled with an automated climate apparatus operated both at steady and dynamic conditions. The control and data acquisition equipment is based on Radotron system, developed to automate the multitasking management of different sets of radon monitors and climatic sensors. A novel approach for testing passive radon monitors with an alpha track detector exposure standard has been developed. It is based on the direct measurement of radon exposure with a set of passive integrating monitors based on the new ENEA piston radon exposure meter. This paper describes the methodological approach on radon metrology, the status-of-art of experimental apparatus and the standardization procedures. (authors)

  6. Models for comparing lung-cancer risks in radon- and plutonium-exposed experimental animals

    International Nuclear Information System (INIS)

    Gilbert, E.S.; Cross, F.T.; Sanders, C.L.; Dagle, G.E.

    1990-10-01

    Epidemiologic studies of radon-exposed underground miners have provided the primary basis for estimating human lung-cancer risks resulting from radon exposure. These studies are sometimes used to estimate lung-cancer risks resulting from exposure to other alpha- emitters as well. The latter use, often referred to as the dosimetric approach, is based on the assumption that a specified dose to the lung produces the same lung-tumor risk regardless of the substance producing the dose. At Pacific Northwest Laboratory, experiments have been conducted in which laboratory rodents have been given inhalation exposures to radon and to plutonium ( 239 PuO 2 ). These experiments offer a unique opportunity to compare risks, and thus to investigate the validity of the dosimetric approach. This comparison is made most effectively by modeling the age-specific risk as a function of dose in a way that is comparable to analyses of human data. Such modeling requires assumptions about whether tumors are the cause of death or whether they are found incidental to death from other causes. Results based on the assumption that tumors are fatal indicate that the radon and plutonium dose-response curves differ, with a linear function providing a good description of the radon data, and a pure quadratic function providing a good description of the plutonium data. However, results based on the assumption that tumors are incidental to death indicate that the dose-response curves for the two exposures are very similar, and thus support the dosimetric approach. 14 refs., 2 figs., 6 tabs

  7. Wind direction correlated measurements of radon and radon progeny in atmosphere: a method for radon source identification

    International Nuclear Information System (INIS)

    Akber, R.A.; Pfitzner, J.; Johnston, A.

    1994-01-01

    This paper describes the basic principles and methodology of a wind direction correlated measurement technique which is used to distinguish the mine-related and background components of radon and radon progeny concentrations in the vicinity of the ERA Ranger Uranium Mine. Simultaneous measurements of atmospheric radon and radon progeny concentrations and wind speed and direction were conducted using automatic sampling stations. The data were recorded as a time series of half hourly averages and grouped into sixteen 22.5 degrees wind sectors. The sampling interval and the wind sector width were chosen considering wind direction variability (σ θ ) over the sampling time interval. The data were then analysed for radon and radon progeny concentrations in each wind sector. Information about the wind frequency wind speed seasonal and diurnal variations in wind direction and radon concentrations was required for proper data analysis and interpretation of results. A comparison with model-based estimates for an identical time period shows agreement within about a factor of two between the two methods. 15 refs., 1 tab., 5 figs

  8. Uranium prospecting through radon detection; La prospection de l'uranium par le radon

    Energy Technology Data Exchange (ETDEWEB)

    Pradel, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1956-07-01

    Prospecting rests on the determination of the concentration of ground air in radon. Radon diffusing from deep uranium bearing layers is detected in upper ground layers. (author) [French] La prospection est basee sur l'etude de la concentration en radon dans l'air du sol. Dans les terrains superficiels, on decele le radon qui diffuse a partir des couches profondes uraniferes. (auteur)

  9. Radon concentration inversions in the troposphere

    International Nuclear Information System (INIS)

    Pereira, E.B.

    1987-07-01

    Vertical concentrations of radon in the lower troposphere were obtained in Southern Brazil up to 7Km high and have shown unexpected inverted profiles. The presence of low pressure center systems southwest to the flight path suggested that inversions might have been originated by a vertical transport mechanism based on the large scale circulation of developing synoptic systems. A simple friction-driven circulation model was contructed and the transport equation was solved. (author) [pt

  10. The discussion on a new measure method of radon chamber leak rate

    International Nuclear Information System (INIS)

    Zhang Junkui; Tang Bing

    2010-01-01

    Radon chamber is the third standard radon source. The leak rate is the key parameter for the radon chamber to naturally and safely operate. One way, that measure the leak rate is introduced. The experience result is that the way is simple and veracious to measure the leak rate. (authors)

  11. Study of Behavior and detection of radon in environmental samples by scintillation method. Application for radium

    International Nuclear Information System (INIS)

    ZAFIMANJATO, J.L.R.

    2007-01-01

    Radon is considered as the major source of radiological exposure of natural radiations to the population. On an international scale, it represents about the half of exposures of natural radiation sources (UNSCEAR, 1993) Radon gets into human body with inhaled air and sometimes with drinking water. Then, the objective of this work is to know the radon concentrations in water and in indoor atmosphere, and the risk in order to set up a method of monitoring and to identify high radon level areas. A specific method of detection using liquid scintillation with special emphasis on α/β discrimination, the use of solvent extractive and enrichment of radionuclides have been developed for the determination of both 222 Rn and 226 Ra in water. The method is simple, rapid and sensitive. In a pilot project for a monitoring of drinking water in Madagascar, it was shown that the proposed method was suitable for a large scale monitoring and routine analysis. Considerable concentrations of radon were found in water and air samples from Vinaninkarena. Radon concentrations obtained by in situ and in laboratory measurements have been compared to the results of an international intercomparison campaigns organised by the German Society for Liquid Scintillation Spectrometry in 2011. A theoretical study of the behavior of radon is porous material containing radium is detailed in order to describe its exhalation phenomena. An assessment model of the dose due to ingestion and liberation of radon from water is presented and compared with other models especially to the Crawford Brown's model. [fr

  12. The April 1994 and October 1994 radon intercomparisons at EML

    International Nuclear Information System (INIS)

    Fisenne, I.M.; George, A.C.; Perry, P.M.; Keller, H.W.

    1995-10-01

    Quality assurance/quality control (QA/QC) are the backbone of many commercial and research processes and programs. QA/QC research tests the state of a functioning system, be it the production of manufactured goods or the ability to make accurate and precise measurements. The quality of the radon measurements in the US have been tested under controlled conditions in semi-annual radon gas intercomparison exercises sponsored by the Environmental Measurements Laboratory (EML) since 1981. The two Calendar Year 1994 radon gas intercomparison exercises were conducted in the EML exposure chamber. Thirty-two groups including US Federal facilities, USDOE contractors, national and state laboratories, universities and foreign institutions participated in these exercises. The majority of the participant's results were within ±10% of the EML value at radon concentrations of 570 and 945 Bq m -3

  13. Development of a portable radon detection system

    International Nuclear Information System (INIS)

    Allen, J.W.

    1976-09-01

    The presence of radon-222 in soil gas and ground water can indicate the existence of nearby uranium deposits even when heavy overburdens completely absorb the associated gamma radiation. Techniques to detect and measure radon have evolved during the past several years to the point where radon prospecting is routinely employed in a number of countries. A program to develop and field test a prototype system for measuring radon from soil gas and water is described. A prototype system employing a flow through scintillation detector was designed and constructed, utilizing standard commercial components, to provide a fieldworthy unit for testing the system concepts. Laboratory and preliminary field tests of this unit indicate that it can detect anomalous radon levels of less than 10 picoCuries per liter (pCi/l) in soil gas and ground water

  14. Sign of Radon for locate geothermic sources

    International Nuclear Information System (INIS)

    Gonzalez Teran, D.

    1991-01-01

    Evaluation of a geothermic field is based upon geological, geophysical and geochemical studies that enable the evaluation of the deposit potential, that is to say, the amount of energy per unit mass, the volume of the trapped fluid, vapor fraction and fluid chemistry. This thesis has as its objective the evaluation of radon gas emanation in high potential geothermic zones in order to utilize the results as a low cost and easy to manage complimentary tool in geothermic source prospection. In chapter I the importance and evaluation of a geothermic deposit is discussed. In chapter II the general characteristics of radon are discussed: its radioactivity and behavior upon diffusion over the earth's surface> Chapter III establishes the approach used in the geothermic field of Los Azufres, Michoacan, to carry out samplings of radon and the laboratory techniques that were used to evaluate the concentration of radon in the subsoil. Finally in chapter IV measurements of radon in the field are compared to geological faults in the area under study. The sampling zones were: low geothermic potential zone of the northern and the southern zone having a greater geothermic potential than that in the north. The study was carried out at different sampling times using plastics detectors of from 30 to 46 days from February to July. From the results obtained we concluded that the emission of radon was greater in the zones of greatest geothermic potential than in the low geothermic potential zones it was also affected by the fault structure and the time of year in which sampling was done. (Author)

  15. A novel detection of radon based on its decay product inducing conformational changes of an aptamer probe

    International Nuclear Information System (INIS)

    Long, Minzhi; Deng, Han; Tian, Gang; Song, Chunli; Liu, Hongwen; Shen, Yi; Lv, Changyin

    2016-01-01

    This study proposes a novel method for the detection of inert gas radon using a label-free, specific, fluorescence-sensing aptamer in the context of PW17-OG system. This method utilizes the cyanine dye OliGreen (OG) as a signal reactor and the aptamer PW17 as a fluorescent identification probe. When OG integrates into the free curling PW17, a strong fluorescence signal is generated. After radon decays, the long lived naturally occurring radon progeny Pb being disposed and introduced to the system. Lead ions induce PW17 to form a stable G-quadruplex, thereby inhibiting the interaction between OG and PW17 and resulting in a reduction of the fluorescence intensity. The fluorescence intensity show a good linear relationship with lead ion and the radon concentration (D), thereinto, We fitted linear regression of radon concentration in the range of 0.92–4.22 (×10"4 Bqhm"−"3) to receive a good relationship between ΔF and the concentration of radon with the detection limit of 1963 Bqhm"−"3. This method has been successfully applied for detecting standard cumulative concentration of radon and the detection limit reached the national standard of China. This sensitive method can exclude radiation damage in field testing, furthermore, it explores a new field in biological analysis using an aptamer to detected inorganic, gaseous, and radioactive materials. - Highlights: • The label-free fluorescence sensor for detection of radon. • This microscale experiment without radiation damage to experimenters and with less harm to environment. • It provides a sensitive, low cost and simple strategy for radon accumulated concentration and lead ion detection.

  16. A novel detection of radon based on its decay product inducing conformational changes of an aptamer probe

    Energy Technology Data Exchange (ETDEWEB)

    Long, Minzhi; Deng, Han; Tian, Gang; Song, Chunli; Liu, Hongwen; Shen, Yi; Lv, Changyin, E-mail: Lchy1955@163.com

    2016-09-14

    This study proposes a novel method for the detection of inert gas radon using a label-free, specific, fluorescence-sensing aptamer in the context of PW17-OG system. This method utilizes the cyanine dye OliGreen (OG) as a signal reactor and the aptamer PW17 as a fluorescent identification probe. When OG integrates into the free curling PW17, a strong fluorescence signal is generated. After radon decays, the long lived naturally occurring radon progeny Pb being disposed and introduced to the system. Lead ions induce PW17 to form a stable G-quadruplex, thereby inhibiting the interaction between OG and PW17 and resulting in a reduction of the fluorescence intensity. The fluorescence intensity show a good linear relationship with lead ion and the radon concentration (D), thereinto, We fitted linear regression of radon concentration in the range of 0.92–4.22 (×10{sup 4} Bqhm{sup −3}) to receive a good relationship between ΔF and the concentration of radon with the detection limit of 1963 Bqhm{sup −3}. This method has been successfully applied for detecting standard cumulative concentration of radon and the detection limit reached the national standard of China. This sensitive method can exclude radiation damage in field testing, furthermore, it explores a new field in biological analysis using an aptamer to detected inorganic, gaseous, and radioactive materials. - Highlights: • The label-free fluorescence sensor for detection of radon. • This microscale experiment without radiation damage to experimenters and with less harm to environment. • It provides a sensitive, low cost and simple strategy for radon accumulated concentration and lead ion detection.

  17. Theory and practice of radon monitoring with charcoal adsorption

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, B L; Cohen, E S

    1983-08-01

    Because of interest in charcoal adsorption as an inexpensive radon monitoring technique that may be suitable for mass data collection, the theory of radon adsorption from air by a charcoal bed is developed, giving numerical estimates at all stages. The method is practical down to air concentrations of about 0.1 pCi/l. A simple charcoal bed is limited by the fact that its response is highly sensitive to the time interval before termination of the exposure, but two simple methods of avoiding this problem are developed. Simple methods for determining the diffusion constant for the charcoal being used, and for optimizing the depth of the charcoal bed, are presented.

  18. [Estimation of effective doses derived from radon in selected SPA centers that use geothermal waters based on the information of radon concentrations].

    Science.gov (United States)

    Walczak, Katarzyna; Zmyślony, Marek

    2013-01-01

    Geothermal waters contain, among other components, soluble radon gas. Alpha radioactive radon is a health hazard to humans, especially when it gets into the respiratory tract. SPA facilities that use geothermal water can be a source of an increased radiation dose to people who stay there. Based on the available literature concerning radon concentrations, we assessed exposure to radon among people - workers and visitors of Spa centers that use geothermal waters. Radon concentrations were analyzed in 17 geothermal centers: in Greece (3 centers), Iran (5), China (4) and India (5). Doses recived by people in the SPA were estimated using the formula that 1 hour exposure to 1 Bq/m3 of radon concentration and equilibrium factor F = 0.4 corresponds to an effective dose of 3.2 nSv. We have found that radon levels in SPAs are from a few to several times higher than those in confined spaces, where geothermal waters are not used (e.g., residential buildings). In 82% of the analyzed SPAs, workers may receive doses above 1 mSv/year. According to the relevant Polish regulations, people receiving doses higher than 1 mSv/year are included in category B of radiation exposure and require regular dosimetric monitoring. Doses received by SPA visitors are much lower because the time of their exposure to radon released from geothermal water is rather short. The analysis of radon concentration in SPA facilities shows that the radiological protection of people working with geothermal waters plays an important role. It seems reasonable to include SPA workers staying close to geotermal waters into a dosimetric monitoring program.

  19. Modeling of indoor radon

    International Nuclear Information System (INIS)

    Paschoa, A.S.

    1990-01-01

    This paper reports on models for radon, which are developed not only to describe the behavior of radon and daughters since the moment that radon is created in natural sources by the alpha decay of 226 Ra up to the point that doses to humans are estimated based on the inhalation of radon and its progeny. The objective of a model should be determinant in defining the model structure and boundaries. Modeling indoors radon is particularly useful when the 226 Ra concentration in building materials and soils can be known before a house will be built with such 226 Ra bearing materials and over 226 Ra rich soils. The reported concentrations of 226 Ra in building materials range from 0.3 Bq · kg -1 in wood to about 2.6 x 10 3 Bq · kg -1 in aerated concrete based on alum shale. 30 In addition, when a house is built on a soil containing a high 226 Ra concentration, radon exhalation from the soil contributes to increase radon concentration indoors. The reported radon exhalation from soils range from 3.4 Bq · m -2 · s -1 in latosolic soil from Osaka, Japan to about 53 mBq · m -2 · s -1 in chernozemic soil from Illinois

  20. Community-Based Investigation of Radon and Indoor Air Quality in Northeast Denver Neighborhoods

    Science.gov (United States)

    Pfotenhauer, D.; Iwasaki, P. G.; Ware, G. E.; Collier, A.; Hannigan, M.

    2017-12-01

    In 2015, Taking Neighborhood Health to Heart (TNH2H), a community-based organization based in Northeast Denver, and researchers from the University of Colorado, Boulder jointly piloted a project to investigate indoor air quality within Denver communities. This pilot study was carried out across 2015-2016 and found higher than actionable-levels for radon across a majority of its participants. These results inspired a continued collaboration between the community group and academic researchers from CU Boulder. The partnership went on to conduct a similar project this last year in which the team again employed a community-based participatory research (CBPR) framework to investigate indoor air pollutants across a broader geographical footprint in Denver's Northeast Neighborhoods. The collaboration sampled 30 participant houses across 5 neighborhoods for radon and volatile organic compounds (VOCs). Although VOC levels were found to be well under thresholds for concern, for the second year of this investigation, radon levels were found on average to be significantly above the EPA's threshold for hazardous levels. Additionally, in collecting survey data on the participants' house characteristics, certain identifiable trends emerged that signal which house types have greater risk of radon intrusion. Having found in two consecutive studies that a majority of homes in these neighborhoods are burdened with dangerous levels of radon, the partnership is now moving towards developing educational and political actions to address the results from these projects and disseminate the information regarding radon levels and threats to these neighborhood communities.

  1. Recommended action levels for radon in dwellings

    International Nuclear Information System (INIS)

    1988-01-01

    The recommendation made by a group appointed by the Directorate of Public Health, arrives at the conclusion that radon in Norwegian dwellings implies a substantial health problem for the country. For this reason it is recommended that actions should be taken to reduce the radiation exposure from radon in Norway. Upper levels for such actions are set to 200 Bq/m 3 (radon in air of dwellings) for new contructions. For existing dwellings having concentrations of 200 - 800 Bq/m 3 , simple and unexpensive remedial actions to reduce levels are sufficient. When levels exceed 800 Bq/m 3 , more elaborate and costly actions are necessary. An evaluation of the extent of the radon problem in Norway is included, together with a survey of the cost and benefit involved in choosing various levels for remedial actions

  2. Radon in houses - identification of sources and pathways of transfer

    International Nuclear Information System (INIS)

    Robe, M.C.; Rannou, A.; Le Bronec, J.

    1992-01-01

    The Institut de Protection et de Surete Nucleaire (IPSN) is studying the remedial actions to reduce high concentration of radon in houses. The first step to know how to modify houses is to identify radon sources and pathways of transfer to upper floors. A pilot study in Brittany was designed to develop a simple method of diagnosis. This investigation was based on indoor and outdoor measurements of 222 Rn activity concentration in the air and 222 Rn area exhalation rate from the soils and walls, measurements of the potential alpha energy concentration of 222 Rn daughters and the ventilation rate. The structural characteristics of houses and the influence of the life style of the inhabitants were examined. Analysis of the results showed that a limited number of parameters can be selected for use in a rapid radon diagnosis. (author)

  3. State-space dynamic model for estimation of radon entry rate, based on Kalman filtering

    International Nuclear Information System (INIS)

    Brabec, Marek; Jilek, Karel

    2007-01-01

    To predict the radon concentration in a house environment and to understand the role of all factors affecting its behavior, it is necessary to recognize time variation in both air exchange rate and radon entry rate into a house. This paper describes a new approach to the separation of their effects, which effectively allows continuous estimation of both radon entry rate and air exchange rate from simultaneous tracer gas (carbon monoxide) and radon gas measurement data. It is based on a state-space statistical model which permits quick and efficient calculations. Underlying computations are based on (extended) Kalman filtering, whose practical software implementation is easy. Key property is the model's flexibility, so that it can be easily adjusted to handle various artificial regimens of both radon gas and CO gas level manipulation. After introducing the statistical model formally, its performance will be demonstrated on real data from measurements conducted in our experimental, naturally ventilated and unoccupied room. To verify our method, radon entry rate calculated via proposed statistical model was compared with its known reference value. The results from several days of measurement indicated fairly good agreement (up to 5% between reference value radon entry rate and its value calculated continuously via proposed method, in average). Measured radon concentration moved around the level approximately 600 Bq m -3 , whereas the range of air exchange rate was 0.3-0.8 (h -1 )

  4. Radon levels reduced through venting of house foundations

    International Nuclear Information System (INIS)

    Sivborg, P.; Johansson, I.; Strindehag, O.

    1981-01-01

    It has been confirmed that the radon emanation from the ground poses a more importent radiation hazard than the radon contained in the building material. In this article a simple system for ventilation of the gases produced under the foundation of a small houses is described. This ventilation system reduced the radondaughters concentration in a house by a factor of ten. (L.E.)

  5. Evaluation of the open vial method in the radon measurement; Evaluacion del metodo del vial abierto en la medicion de radon

    Energy Technology Data Exchange (ETDEWEB)

    Lopez del Rio, H.; Davila R, J. I.; Mireles G, F., E-mail: hlopezdelrio@hotmail.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-10-15

    The open vial method is a simple technique, under-utilized but that take advantage of the great radon solubility in organic solvents, therefore applies in the measurement of the radon concentration exhaled in soil. The method consists on the exposition to the gas radon of an open vial with scintillating solution. An integral mathematical model for indoors that describes the emanation processes and gas radon exhalation was developed, as well as the radon dissolution in the scintillation liquid, besides obtaining the characteristic parameters of the experimental system proposed for the radon concentration calculation exhaled by soils. Two experimental arrangements were designed with exposition cameras of 12 and 6 L and quantity of different soil. The open vial was prepared with a mixture of 8 ml of deionized water and 12 ml of scintillation liquid OptiPhase Hi Safe 3 in polyethylene vials; the measurements of the dissolved radon were carried out in scintillation liquid equipment. As a result, on average 2.0% of the exhaled radon is dissolved in the open vial and the dissolved fraction is independent of the experimental arrangement. Also was observed that the exposition time does not affect the radon dissolution significantly, in correspondence with the reported in the literature. (Author)

  6. Radon exposure at specific workplaces in Austria experiences and future challenges

    International Nuclear Information System (INIS)

    Gruber, V.; Ringer, W.

    2017-01-01

    Radon exposure at specific workplaces like water works, radon spas, tourist mines and show caves were evaluated in Austria within pilot studies (2004-10) and have been regulated in an ordinance since 2008. In this article, the major results and experiences in radon measurements and dose assessments at those workplaces by the accredited AGES laboratory are presented. (authors)

  7. Radon discrimination for work place air samples

    International Nuclear Information System (INIS)

    Bratvold, T.

    1994-01-01

    Gross alpha/beta measurement systems are designed solely to identify an incident particle as either an alpha or a beta and register a count accordingly. The tool of choice for radon identification, via decay daughters, is an instrument capable of identifying the energy of incident alpha particles and storing that information separately from detected alpha emissions of different energy. In simpler terms, the desired instrument is an alpha spectroscopy system. K Basins Radiological Control (KBRC) procured an EG ampersand G ORTEC OCTETE PC alpha spectroscopy system to facilitate radon identification on work place air samples. The alpha spectrometer allows for the identification of any alpha emitting isotope based on characteristic alpha emission energies. With this new capability, KBRC will explicitly know whether or not there exists a true airborne concern. Based on historical air quality data, this new information venue will reduce the use of respirators substantially. Situations where an area remains ''on mask'' due solely to the presence of radon daughters on the grab air filter will finally be eliminated. This document serves to introduce a new method for radon daughter detection at the 183KE Health Physics Analytical Laboratory (HPAL). A new work place air sampling analysis program will be described throughout this paper. There is no new technology being introduced, nor any unproven analytical process. The program defined over the expanse of this document simply explains how K Basins Radiological Control will employ their alpha spectrometer

  8. Estimation of effective doses derived from radon in selected SPA centers that use geothermal waters based on the information of radon concentrations

    Directory of Open Access Journals (Sweden)

    Katarzyna Walczak

    2013-04-01

    Full Text Available Background: Geothermal waters contain, among other components, soluble radon gas. Alpha radioactive radon is a health hazard to humans, especially when it gets into the respiratory tract. SPA facilities that use geothermal water can be a source of an increased radiation dose to people who stay there. Based on the available literature concerning radon concentrations, we assessed exposure to radon among people - workers and visitors of Spa centers that use geothermal waters. Material and Methods: Radon concentrations were analyzed in 17 geothermal centers: in Greece (3 centers, Iran (5, China (4 and India (5. Doses recived by people in the SPA were estimated using the formula that 1 hour exposure to 1 Bq/m3 of radon concentration and equilibrium factor F = 0.4 corresponds to an effective dose of 3.2 nSv. Results: We have found that radon levels in SPAs are from a few to several times higher than those in confined spaces, where geothermal waters are not used (e.g., residential buildings. In 82% of the analyzed SPAs, workers may receive doses above 1 mSv/year. According to the relevant Polish regulations, people receiving doses higher than 1 mSv/year are included in category B of radiation exposure and require regular dosimetric monitoring. Doses received by SPA visitors are much lower because the time of their exposure to radon released from geothermal water is rather short. Conclusions: The analysis of radon concentration in SPA facilities shows that the radiological protection of people working with geothermal waters plays an important role. It seems reasonable to include SPA workers staying close to geotermal waters into a dosimetric monitoring program. Med Pr 2013;64(2:193–198

  9. Instruments to measure radon activity concentration or exposure to radon. Interlaboratory comparison 2011

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2011-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by BfS. A radon measuring service is recognized by the competent authority if it proves its organizational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the website www.bfs.de/de/ion/radon/fachinfomessung/vergleichspruefungen.html and from the European Information System on Proficiency Testing Schemes (eptis) available in the internet. (orig.)

  10. Monitoring radon reduction in Clinton, New Jersey houses

    International Nuclear Information System (INIS)

    Osborne, M.C.; Brennan, T.; Michaels, D.

    1987-01-01

    In 1986, a preliminary survey of houses in Clinton, New Jersey, conducted by the New Jersey Department of Environmental Protection (DEP), identified more than 50 houses with indoor radon concentrations greater than 100 pCi/l in the subdivision of Clinton Knolls. Many of these houses had radon concentrations of 600 pCi/l or higher. At the request of the New Jersey DEP, EPA's Air and Energy Engineering Research Laboratory, AEERL, initiated a project to develop and demonstrate cost-effective radon reduction techniques in 10 representative Clinton Knolls houses. Radon reduction was to be completed before the beginning of the 1986-1987 heating season to keep the exposure of residents to a minimum. Additional data were collected to add to the general body of information on radon transport and its control in houses; however, the data collected in this study were secondary to the pressing need of demonstrating effective radon reduction techniques. The authors describe these techniques and discuss the data on radon transport and control in this project

  11. Study of radon emanation from uranium mill tailings. Relations between radon emanating power and physicochemical properties of the material; Etude de l'emanation du radon a partir de residus de traitement de minerais d'uranium. Mise en evidence de relations entre le facteur d'emanation et les caracteristiques du materiau

    Energy Technology Data Exchange (ETDEWEB)

    Pellegrini, D

    1999-07-01

    The uranium extraction from ores leads to large amounts of mill tailings still containing radionuclides, such as thorium-230 and radium-226, which generate radon-222. Without protective action, radon exposition may be high enough to cause concern for health of populations living in the vicinity of an uranium mill tailings disposal. This exposition pathway has therefore to be taken into account in the radiological impact studies. The emanating power, i.e. the part of radon atoms which escape from the solid particles, is directly involved in the radon source term evaluation. It may be determined for a given material by laboratory measurements. Emanating powers from 0.08 to 0.33 have been obtained for mill tailings from Jouac (Limousin, France), at various moisture contents. In order to reduce the relations of dependence between some of the emanation parameters, more simple phases, kaolinite and polymeric resins, have been studied. Those experiments have led us to the selection of the mechanisms and the parameters to consider for the development of an emanation modelling. The whole of the results obtained point out the radon sorption, in various proportions depending on the materials. The moisture content influence on the emanation from materials containing fine particles have been confirmed: the emanation increases with this parameter until a continuous water film surrounding the particles have been formed, and then become constant. This 'water effect' occurs in a moisture content range, which depends on the material porosity. Elsewhere, the presence of amorphous phases may led to a high radon emanation. (author)

  12. Current status of radon and radium monitoring at the Federal University of Technology (UTFPR), PR, Brazil

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine N.; Kappke, Jaqueline; Schelin, Hugo R.; Denyak, Valeriy; Barbosa, Laercio; Perna, Allan F.N.

    2011-01-01

    Numerous and systematic studies performed in different countries for many decades resulted in the explicit conclusion that radon exposure, as well as its progeny, is the main cause of lung cancer among non-smokers. All three natural radon isotopes ( 222 Rn, 220 Rn and 219 Rn) are produced in the three principal natural radioactive decay chains. Specifically, the 222 Rn is produced by the decay series of 238 U and proceeded from α-decay of 226 Ra. Current work describes the present status and obtained results concerning indoor radon survey in dwellings, radon in water supply and soil gas tests performed by the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR) within Curitiba urban area. For radon in air activity measurements, it was used polycarbonate etched track detectors such as LEXAN (GE) and CR-39, mounted in diffusion chambers. For soil gas measurements, the experimental setup was based on the Professional Radon Monitor (AlphaGUARD, Genitron/SAPHYMO) connected to the air pump with filter vessels and to specially developed in our Laboratory the Soil Gas Probe. In the case of radon tests in drinking water, the experimental setup was based on the AlphaGUARD Radon monitor and Electronic radon detector RAD7 (Durridge Company, Inc.) connected to special kit of glass vessels through the air pump. Obtained results permitted to identify few dwellings where radon concentration in air was found bigger than 600 Bq/m 3 which is considered as the action level by most of the European Community and the World Health Organization (WHO). In the case of studied artesian wells, collected samples of water presented the average 222 Rn activity about 60 Bq/L which is 6 times bigger than maximum level recommended by USEPA. Some artesian wells presented the radon activity of almost 200 Bq/L. More over, it was identified the radioactivity of radium ( 226 Ra) salts which are soluble in water and almost all water samples presented results bigger than

  13. Construction materials and Radon

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine Nicolosi; Loriane, Fior; Schelin, Hugo R.; Pottker, Fabiana; Paula Melo, Vicente de

    2008-01-01

    Full text: Current studies have been performed with the aim to find the correlation of radon concentration in the air and used construction materials. At the first stage of the measurements different samples of materials used in civil construction were studied as a source of radon in the air and at the second step it was studied the radon infiltration insulation using different samples of finishing materials. For 222 Rn concentration measurements related to different construction materials as well as for the studies of radon emanation and its reduction, the sealed cell chambers, of approximately 60 x 60cm 2 , have been built using the ceramic and concrete blocks. This construction has been performed within protected and isolated laboratory environment to maintain the air humidity and temperature stable. These long term measurements have been performed using polycarbonate alpha track passive detectors. The exposure time was set about 15 days considering previous calibration performed at the Institute of Radiation Protection and Dosimetry (IRD/CNEN), where the efficiency of 70% was obtained for the density of alpha particle tracks about 13.8 cm -2 per exposure day and per kBq/m 3 of radon activity concentration. The chemical development of alpha tracks has been achieved by electrochemical etching. The track identification and counting have been done using a code based on the MATLAB Image Processing Toolbox. The cell chambers have been built following four principle steps: 1) Assembling the walls using the blocks and mortar; 2) Plaster installation; 3) Wall surface finishing using the lime; 4) Wall surface insulation by paint. Making the comparison between three layers installed at the masonry walls from concrete and ceramic blocks, it could be concluded that only wall painting with acrylic varnish attended the expectation and reduced the radon emanation flow by the factor of 2.5 approximately. Studied construction materials have been submitted the instant

  14. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres. Progress report, July 1, 1991--June 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report covers the second year of the 28 month grant current grant to Clarkson University to study the chemical and physical behavior of the polonium 218 atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and it dose to the cells in the respiratory tract are to be fully assessed. Two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical process that affect the progeny`s atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. This report describes the progress toward achieving these objectives.

  15. Exposure to radon in Australian tourist caves

    International Nuclear Information System (INIS)

    Solomon, S.B.; Langroo, R.; Lyons, R.G.

    1994-01-01

    In 1991 the International Commission on Radiological Protection(ICRP) produced guidelines and recommendations dealing with workplace exposure to elevated background radiation, in particular, the risk associated with the inhalation of radon and radon progeny. An intervention level of 1000 Bq m -3 has been proposed. Australia has over 40 tourist caves, under the management of the various State Departments or private groups. The limited data available on radon levels in Australian caves would suggest that some of these caves may be in excess of the proposed intervention level, thus presenting a potential health risk for the cave guides. This paper summarises the current information on radon in Australian caves and describes the proposed methodologies to be used for a Worksafe Australia-funded survey of radon levels in Tourist caves within Australia. This survey is to be carried out jointly by researchers at the Australian Radiation Laboratory, University of Auckland and the University of Sydney, during 1994 and 1995. 7 refs., 3 tabs

  16. Training and accreditation for radon professionals in Sweden

    International Nuclear Information System (INIS)

    Mjoenes, L.; Soederman, A.-L.

    2004-01-01

    Radon training courses and seminars on radon have been arranged in Sweden since the early 1980s. A commercial educational company initiated the first regular training courses in 1987. Up to 1990 about 400 persons had attended courses in radon measurement and radon mitigation methods. In 1991 the training programme was taken over by the Swedish Radiation Protection Authority, SSI. Today SSI's Radon Training Programme comprises three different two-day courses, a Basic Radon Course and two continuation courses: Radon Measurements and Radon in Water. Until 2003 SSI also arranged courses about Radon Remedial Measures and Radon Investigation and Risk Map Production. The courses are arranged twice a year. Altogether, about 750 municipal environmental health officers and technicians from private companies have been educated in the SSI training programme between 1991 and 2003. The continuation courses are completed with an examination, consisting of a theoretical test. The names of the persons who pass are being published in a list that is found on the SSI web site. Since no certification system is currently in place for radon professionals in Sweden, this list helps people who need to get in contact with radon counsellors to find one in their area and is used by authorities as well as private house-owners. Since 1991 it has been possible to obtain accreditation for measurements of indoor radon in Sweden and since 1997, also for measurements of radon in water. Although accreditation is voluntary in Sweden, accredited laboratories perform most measurements, both for indoor air and water. Passing the examination in the SSI training courses is a condition for accreditation. The Swedish Board for Accreditation and Conformity Assessment, SWEDAC, is in charge of the accreditation. So far, three major companies have obtained accreditation for measurement of indoor radon and four have been accredited for measurements of radon in water

  17. The mechanical ventilation of suspended timber floors for radon remediation - a simple analysis

    International Nuclear Information System (INIS)

    Woolliscroft, M.

    1994-01-01

    Mechanical ventilation of the underfloor space is one of the most effective ways of reducing radon levels in buildings with suspended timber floors. There is a question, however, whether this ventilation should be supply or extract, sometimes extract is more effective, sometimes supply is more effective. This report presents a simple analysis of the problem and suggests the hypothesis that the relative effectiveness of supply or extract ventilation to the underfloor space depends on the relative airtightness of the floor and the soil or oversite surface. The analysis suggests that if the floor is relatively tight then supply ventilation may be more effective whereas if the floor is relatively leaky or there is oversite concrete then extract may be better. It is suggested that in either case it is better to keep the underfloor pressure low and that when mechanical ventilation is provided to the underfloor space it may be necessary to increase the number of airbricks. (author)

  18. Radon gas monitoring survey for the determination of Radon Prone Areas in Lombardia

    Energy Technology Data Exchange (ETDEWEB)

    Bartolo, D. de; Alberici, A.; Gallini, R.; Maggioni, T.; Mondini, A.; Zini, E. [A.R.P.A. della Lombardia, Milano (Italy); Arrigoni, S.; Cazzaniga, P.; Cugini, A.; Gallinari, G.; Olivieri, F.; Romanelli, M. [A.R.P.A. della Lombardia, Dipt. di Bergamo, Bergamo (Italy)

    2006-07-01

    Region Lombardia has carried out a radon gas monitoring survey on its territory to localize radon prone areas as by law 241/00 enacted. To plan the survey, the Lombardia territory has been divided into two different types according to the morphology as well as the presence of a substratum of rock. The area with hills and mountains has been investigated with more attention compared to the plain because we can assume higher variability in radon concentration distribution due to the geological and morphological characteristics. The territory subdivision was based on the standard grid.. of the techniregional cartography (8 x 5 km). To perform radon indoor concentration measurements about 3600 measuring points were selected. They are located at the ground floor of buildings with the characteristics to ensure the tests are representative and comparable. It has also been taken into account evaluations done with previous surveys in accordance with the defined specification of the sites. The measurements were carried out using C.R. 39 trace detector technique. The detectors were contained in closed plastic canisters and they were positioned in situ for one year and measured each semester. The detectors were chemically treated and the traces counted using the automated optical system installed at the Radiometric Laboratory of the A.R.P.A. Department in Bergamo. The instrument accuracy and precision were evaluated using data obtained with different methods: using detectors exposed to radon known concentrations, participating to an international intercomparison as well as exposing the detector in a national calibration centre. Due to the large amount of detectors involved, a particular attention was taken for the detector homogeneity response and for the optimization of the analysis parameters. For further investigating the reliability of the measurements, two detectors were used in parallel in 10% of the tests. The results show higher values in the areas of Bergamo, Brescia

  19. The Effect of Combining Analogy-Based Simulation and Laboratory Activities on Turkish Elementary School Students' Understanding of Simple Electric Circuits

    Science.gov (United States)

    Unlu, Zeynep Koyunlu; Dokme, Ibilge

    2011-01-01

    The purpose of this study was to investigate whether the combination of both analogy-based simulation and laboratory activities as a teaching tool was more effective than utilizing them separately in teaching the concepts of simple electricity. The quasi-experimental design that involved 66 seventh grade students from urban Turkish elementary…

  20. Establishing the level of exposure to radon gas in dwellings

    International Nuclear Information System (INIS)

    Karupa, Jackson Uakaningirua

    2016-04-01

    The main source of natural internal irradiation of man is radon and its decay products. In this study, the radon concentration levels in selected dwellings in Erongo region, Swakopmund, Namibia will be estimated using passive or active radon detector. The primary objective of the study is to measure and establish radon levels in selected dwellings in Erongo region, Swakopmund of Namibia. Measurements will be carried out for the period of twelve months and after three months period the detectors will be exchanged for laboratory analysis. The results obtained from the study will reveal the concentration of radon in most of the selected dwellings in Erongo region, Swakopmund, Namibia. Once Radon level is measured or identified, the results with data from work done in other environments in Africa and elsewhere will be compared. In case of high radon concentrations in dwelling, the occupants will be advised to ensure good ventilation practices as cost effective means of mitigation of indoor radon gas level in the area. (au)

  1. Control of indoor radon and radon progeny concentrations

    International Nuclear Information System (INIS)

    Sextro, R.G.

    1985-05-01

    There are three general categories of techniques for the control of radon and radon progeny concentrations in indoor air - restriction of radon entry, reduction of indoor radon concentrations by ventilation or air cleaning, and removal of airborne radon progeny. The predominant radon entry process in most residences appears to be pressure driven flow of soil gas through cracks or other openings in the basement, slab, or subfloor. Sealing these openings or ventilation of the subslab or subfloor space are methods of reducing radon entry rates. Indoor radon concentrations may be reduced by increased ventilation. The use of charcoal filters for removal of radon gas in the indoor air by adsorption has also been proposed. Concentrations of radon progeny, which are responsible for most of the health risks associated with radon exposures, can be controlled by use of electrostatic or mechanical filtration. Air circulation can also reduce radon progeny concentrations in certain cases. This paper reviews the application and limitations of each of these control measures and discusses recent experimental results

  2. Radon levels in Oslo schools

    International Nuclear Information System (INIS)

    Birovlev, A.

    2004-01-01

    Radon measurements using passive CR-39 detectors have been conducted in all schools in Oslo municipality during winter 2003/2004. Results are presented and discussed in the light of qualitative and quantitative factors, some of which are specific for schools as workplaces. Analysis is conducted with respect to factors relating to building construction type, ventilation principle, age of building, building size etc. The influence of ventilation type on radon levels is studied, and problems of investigations based purely on conventional passive radon detectors are noted. Over-estimation of radon concentration by passive detectors and day-night variations of indoor radon levels in buildings with mechanical ventilation systems are discussed. Several guiding principles for planning similar investigations based on above discussions are outlined. (author)

  3. Potential for bias in epidemiologic studies that rely on glass-based retrospective assessment of radon

    International Nuclear Information System (INIS)

    Weinberg, C.R.

    1995-01-01

    Retrospective assessment of exposure to radon remains the greatest challenge in epidemiologic efforts to assess lung cancer risk associated with residential exposure. An innovative technique based on measurement of α-emitting, long-lived daughters embedded by recoil into household glass may one day provide improved radon dosimetry. Particulate air pollution is known, however, to retard the plate-out of radon daughters. This would be expected to result in a differential effect on dosimetry, where the calibration curve relating the actual historical radon exposure to the remaining α-activity in the glass would be different in historically smoky and nonsmoky environments. The resulting open-quotes measurement confoundingclose quotes can distort inferences about the effect of radon and can also produce spurious evidence for synergism between radon exposure and cigarette smoking. 18 refs., 4 figs

  4. Radon transport modelling: User's guide to RnMod3d

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, C.E

    2000-08-01

    RnMod3d is a numerical computer model of soil-gas and radon transport in porous media. It can be used, for example, to study radon entry from soil into houses in response to indoor-outdoor pressure differences or changes in atmospheric pressure. It can also be used for flux calculations of radon from the soil surface or to model radon exhalation from building materials such as concrete. The finite-volume model is a technical research tool, and it cannot be used meaningfully without good understanding of the involved physical equations. Some understanding of numerical mathematics and the programming language Pascal is also required. Originally, the code was developed for internal use at Risoe only. With this guide, however, it should be possible for others to use the model. Three-dimensional steady-state or transient problems with Darcy flow of soil gas and combined generation, radioactive decay, diffusion and advection of radon can be solved. Moisture is included in the model, and partitioning of radon between air, water and soil grains (adsorption) is taken into account. Most parameters can change in time and space, and transport parameters (diffusivity and permeability) may be anisotropic. This guide includes benchmark tests based on simple problems with known solutions. RnMod3d has also been part of an international model intercomparison exercise based on more complicated problems without known solutions. All tests show that RnMod3d gives results of good quality. (au)

  5. Radon-222 measurements at Chester

    International Nuclear Information System (INIS)

    Fisenne, I.M.

    1982-01-01

    The Environmental Measurements Laboratory has compiled a five year record of continuous hourly radon-222 measurements at Chester, New Jersey. The data for the 1977-1978, 1978-1979, 1979-1980, and 1980-1981 have been reported previously

  6. Measurement of the radon exhalation rate from the medium surface by tracing the radon concentration

    International Nuclear Information System (INIS)

    Yanliang Tan; Detao Xiao

    2013-01-01

    The paper will present a method based on the accumulation chamber technique for measuring of radon exhalation from the medium surface. A radon monitor traces the change of radon concentration in the accumulation chamber, and then the radon exhalation can be obtained accurately through linear fit. Based on our recent experiments, the radon exhalation rate from the medium surface obtained from this method is in good agreement with the actual exhalation rate of our simulation facility. This method is superior to the competition method which obtains the radon exhalation through the exponential fit by an external PC-system. The calculation for the exponential fit is very easy by computer and related software. However, for portable instruments, the single chip microcomputer can't calculate the exponential fit rapidly. Thus, this method is usable for developing the new portable instrument to classify building materials, etc. (author)

  7. Radon emanometric technique for 226Ra estimation

    International Nuclear Information System (INIS)

    Mandakini Maharana; Sengupta, D.; Eappen, K.P.

    2010-01-01

    Studies on natural background radiation show that the major contribution of radiation dose received by population is through inhalation pathway vis-a-vis contribution from radon ( 222 Rn) gas. The immediate parent of radon being radium ( 226 Ra), it is imperative that radium content is measured in the various matrices that are present in the environment. Among the various methods available for the measurement of radium, gamma spectrometry and radiochemical method are the two extensively used measurement methods. In comparison with these two methods, the radon emanometric technique, described here, is a simple and convenient method. The paper gives details of sample processing, radon bubbler, Lucas cell and the methodology used in the emanometric method. Comparison of emanometric method with gamma spectrometry has also undertaken and the results for a few soil samples are given. The results show a fairly good agreement among the two methods. (author)

  8. Training and Accreditation for Radon Professionals in Sweden

    International Nuclear Information System (INIS)

    Soderman, A. L.

    2003-01-01

    Radon training courses and seminars of different kinds have been arranged in Sweden since the early 1980s. A commercial educational company initiated the first regular training courses in 1987. Up to 1990 about 400 persons had attended courses in radon measurement and radon mitigation methods. In 1991 the first in a series of courses focussed on radon from the ground and production of radon risk maps organised. From 1991 it has been possible to obtain accreditation for measurements of indoor radon in Sweden and from 1997 also for measurements of radon in water. Even if accreditation s is voluntary, in Sweden accredited laboratories perform most measurements, both for indoor air and water. A condition for accreditation in to have passed the examination following the training courses at SSI, SO far, three major companies have obtained accreditation for measurement of indoor radon and four have been accredited for measurements of radon in water. Education on radon is also given at universities and institutes of technology. A two-day course is included in the education for environmental health officers. A number of training courses aimed at real state agents have been organised by SSI through the years. During the autumn of 2001 altogether 400 authorised real estate agents attended a series of regional half-day courses. In 1995 SSI arranged an international training course, Radon Indoor Risk and Remedial Actions, in Stockholm for the European commission. About 40 scientists from all over Europe attended the course, which much appreciated by the participants. Today SSI's Radon Training Programme comprises five different courses, a Basic radon Course and four continuation courses: Radon measurements, Radon remedial measures, Radon in water and Radon investigation and risk map production. The courses are arranged twice a year, in spring and autumn, except the Radon risk map production course, which is arranged about every second year. Altogether, between 1991 and 2003

  9. Radon in soil gas

    International Nuclear Information System (INIS)

    Rector, H.E.

    1990-01-01

    This paper presents the results of a technology review conducted to identify and organize the range of options for measuring radon in soil gas as a means to evaluate radon exposure potential in buildings. The main focus of the review includes identifying the following: Measurement of objectives - the specific parameter(s) that each technology is designed to measure( e.g., soil gas concentration, flux density, etc.); Equipment needs -commercial availability of systems and/or components, specifications for fabricated components; Procedural information - documented elements of field and laboratory methodology and quality assurance; Underlying assumptions - conceptual and mathematical models utilized to convert analytical outcomes to estimators of radon. Basic technologies and field data were examined from a generic perspective (e.g., the common denominators of passive detectors, hollow sampling probes, flux monitors)( as well as specific configurations developed by individual investigators (e.g., sample volume, depth) to develop the basis for separating analytical uncertainties form sampling uncertainties

  10. Radon

    Energy Technology Data Exchange (ETDEWEB)

    Weigel, F [Muenchen Univ. (Germany, F.R.). Inst. fuer Anorganische Chemie

    1978-09-01

    The noble gas radon, formerly called emanation, was discovered a few years after radium. /sup 222/Rn, the longest-lived isotope, has a half-life of 3,82 days. This half life is so short that the experimental techniques available at present (1978) are not sufficient for a characterization of defined radon compounds, even though there are definite indications for the existence of such compounds, and one may expect such radon compounds to be even more stable than the numerous known xenon compounds. - The radon isotopes /sup 219/Rn (Actinon), /sup 220/Rn (Thoron), and /sup 222/Rn (Radon) occur in nature despite their rather short half-lives, because they are continously generated from their mothers /sup 223/Ra, /sup 224/Ra, and /sup 226/Ra, which are in secular equilibrium with long-lived isotopes /sup 235/U, /sup 238/U, and /sup 232/Th, and are in turn continously formed from these long-lived isotopes. Since the radon isotopes are gases, they enter the atmosphere and are carried for long distances with air currents. - Because radon is so short-lived, its practical applications are rather limited. For medical applications, small sealed glass tubes filled with radon are used as radiation sources after the radon has decayed, because the whole series of Po-, Bi-, and Pb-isotopes of the radium decay chain are formed, whose penetrating radiation is useful for therapy. When solids are spiked with Ra isotopes, radon is evolved at a constant rate. On heating such solids, phase transitions show up by sudden increased radon evolution (Hahn's emanation method). - On the basis of nuclear theoretical calculations, there is hardly a chance for the discovery of a long-lived radon species. Therefore, major progress in radon chemistry is hardly to be expected in the near future.

  11. Distribution of indoor radon levels in Mexico

    CERN Document Server

    Espinosa, G; Rickards, J; Gammage, R B

    1999-01-01

    Our laboratory has carried out a systematic monitoring and evaluation of indoor radon concentration levels in Mexico for ten years. The results of the distribution of indoor radon levels for practically the entire country are presented, together with information on geological characteristics, population density, socioeconomic levels of the population, and architectural styles of housing. The measurements of the radon levels were made using the passive method of nuclear tracks in solids with the end-cup system. CR-39 was used as the detector material in combination with a one-step chemical etching procedure and an automatic digital- image counting system. Wherever a high level was measured, a confirming measurement was made using a dynamic method. The results are important for future health studies, including the eventual establishment of patterns for indoor radon concentration, as it has been done in the USA and Europe.

  12. Instruments to measure radon-222 activity concentration or exposure to radon-222. Intercomparison 2014

    International Nuclear Information System (INIS)

    Foerster, Elisabeth; Beck, Thomas; Buchroeder, Helmut; Doering, Joachim; Schmidt, Volkmar

    2014-10-01

    According to the Directive 96/29/EURATOM the monitoring of occupational radiation exposures shall base on individual measurements carried out by an approved dosimetric service. Pursuant to the European Directive an approved dosimetric service is a body responsible for the calibration, reading or interpretation of individual monitoring devices.., whose capacity to act in this respect is recognized by the competent authorities. This concept will also be applied to radon services issuing passive radon measurement devices. Passive radon measurement devices 1 using solid state nuclear track detectors or electrets are recommended for individual monitoring of exposures to radon. German regulations lay down that radon measuring devices are appropriate for purposes of occupational radiation monitoring if the devices are issued by recognized radon measurement services, and the measurement service submits devices of the same type issued for radon monitoring to regular intercomparisons conducted by the Bundesamt fuer Strahlenschutz (BfS). A radon measuring service is recognized by the competent authority if it proves its organisational and technical competence, e. g. by accreditation. These regulations have been introduced in the area of occupational radiation exposures. Nevertheless, it is recommended that radon measuring services which carry out radon measurements in other areas (e.g. dwellings) should subject themselves to these measures voluntarily. The interlaboratory comparisons comprise the organization, exposure, and evaluation of measurements of radon activity concentration or exposure to radon. The comparisons only concern radon-222; radon-220 is not in the scope. Radon services being interested can get further information from the European Information System on Proficiency Testing Schemes (EPTIS) and from the BfS websites.

  13. Review of existing instrumentation and evaluation of possibilities for research and development of instrumentation to determine future levels of radon at a proposed building site

    International Nuclear Information System (INIS)

    1983-01-01

    The rate at which radon enters houses from the soil depends on the pressure differential between the house and the soil, the resistance of the soil to gas movement, and the radon release rate of the soil near the house. The pressure differential between house and soil is caused by wind forces and temperature differences, which depend on the size of the building and the season, and are therefore almost independent of the site location. The soil resistance (permeability) and radon release rate are site specific, and a computer study of radon movement through the soil suggested that these parameters could be combined to give a Radon Index Number (RIN) for a site that would be proportional to the radon entry rate into a typical house. Regional RIN estimates would be produced using existing airborne gamma survey maps to estimate average soil radon release rate, plus agricultural soil classification maps to estimate permeability. Area RIN estimates would be produced using portable gamma spectroscopy equipment to estimate soil radon release rates over an area, plus simple soil grain size analysis techniques to estimate permeability. Site RIN estimates would be produced using laboratory techniques to measure both the radon release rate and the permeability of several undisturbed soil core samples taken at depths over the site. These would provide the most accurate value of RIN possible for a given site

  14. Methodology developed to make the Quebec indoor radon potential map

    International Nuclear Information System (INIS)

    Drolet, Jean-Philippe; Martel, Richard; Poulin, Patrick; Dessau, Jean-Claude

    2014-01-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m 3 in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for each

  15. Testing and design of radon resisting membranes based on the experience from the Czech Republic

    International Nuclear Information System (INIS)

    Jiranek, M.

    2004-01-01

    Testing of barrier properties of insulating materials against radon is usually based on the measurement of the radon diffusion coefficient. Presented report summarizes results of radon diffusion coefficients measurements in more than 120 insulating materials obtained throughout Europe. All measurements were performed by the Czech Technical University, Faculty of Civil Engineering in cooperation with the Radiation Protection Institute. We have found out that great differences exist in diffusion properties, because the diffusion coefficients vary within eight orders from 10 -15 m 2 /s to 10 -8 m 2 /s. For each material category of different chemical composition statistical evaluation of results is presented. Possibilities of usage of the radon diffusion coefficient for the design of radon resisting membranes are discussed. Based on the experience from the Czech Republic the paper is trying to show that controlling applicability of membranes by setting of the upper limit for the radon diffusion coefficient is not a convenient approach. The main reason is that it is almost impossible to choose correctly one limit value for the whole Europe. The second reason is that a great number of common waterproofing materials have their radon diffusion coefficients above the probable limit value. As a consequence of this the protection against radon will be solved preferably by materials with Al foils, which is from the technical point of view meaningless, because membranes with Al foils have very low elongation and therefore they can very easily loose their barrier properties by destroying of the Al foil. The paper will show that it seems to be reasonable to replace strict limits by the real design of the insulation in dependence on particular building and soil characteristics. The design is proposed to be based on the calculation of the insulation thickness according to the formula: d ≥ l.arc sinh ((α 1 .l.λ.C S .(A f + A w ))/C dif .n.V)) (in m), where C S is the third

  16. Improved radon-flux-measurement system for uranium-tailings pile measurement

    International Nuclear Information System (INIS)

    Freeman, H.D.

    1981-10-01

    The Pacific Northwest Laboratory (PNL) is developing cover technology for uranium mill tailings that will inhibit the diffusion of radon to the atmosphere. As part of this cover program, an improved radon flux measurement system has been developed. The radon measurement system is a recirculating, pressure-balanced, flow-through system that uses activated carbon at ambient temperatures to collect the radon. With the system, an area of 0.93 m 2 is sampled for periods ranging from 1 to 12 h. The activated carbon is removed from the radon trap and the collected radon is determined by counting the 214 Bi daughter product. Development of the system included studies to determine the efficiency of activated carbon, relative calibration measurements and field measurements made during 1980 at the inactive tailings pile in Grand Junction, Colorado. Results of these studies are presented

  17. Intercomparison of radon gas detectors 1999 and 2000 at PSI

    International Nuclear Information System (INIS)

    Schuler, Christoph; Butterweck, Gernot

    2000-10-01

    This report describes the results of two radon intercomparison exercises performed by the Reference Laboratory for Radon Gas Activity Concentration Measurements at Paul Scherrer Institut from Sep 9th to Oct 6th, 1999, and from March 21st to 28th, 2000. Radon gas detectors and instruments were exposed in the PSI Radon Chamber in reference atmospheres to 1060 kBqhm -3 radon gas exposure at an average radon gas concentration of 6400 Bqm -3 and to 2050 kBqhm -3 radon gas exposure at an average radon gas concentration of 12500 Bqm -3 , respectively. These intercomparison exercises determined the performance of electret ionisation chambers, track etch detectors and measuring instruments at high humidity (1999 Intercomparison Exercise) and at a high radon gas exposure (2000 Intercomparison Exercise). In the 1999 Intercomparison Exercise, electret ionisation chambers revealed an influence on high humidity. This effect may be due to impurities on a microscopic scale on the electrets of these detectors. With few exceptions, in both the 1999 and the 2000 Radon Intercomparison Exercise the deviations of the measurement results to the reference radon gas concentration values were less than 15% (traceability criterion) and the standard deviation of the results of five detectors less than 15% (reproducibility criterion). (author) [de

  18. Radon, a real threat to our health

    International Nuclear Information System (INIS)

    Mauna, T.; Mauna, A.; Ghita, R.

    2005-01-01

    Radon is invisible, odorless and tasteless a radioactive gas that comes from the radioactive decay of naturally occurring uranium and thorium in soil and rock, can concentrate in domestic homes, overground workplaces, and caves. Radon has been identified as the second leading cause of lung cancers in the U.S., about 20.000 per year, and is present in millions of homes. The Environmental Protection Agency (EPA) of USA designated January 2005 as National Radon Action Month (NRAM) and held the second week of October every year as National Radon Action Week (NRAW). The focus of NRAM and NRW is to promote awareness about, testing for and mitigation of indoor radon gas with various events and outreach campaigns. The EPA considering radon exposure as capital problem for the population health decided to have a special dedicated free phone number the similar for every county state of USA taking into account the increase easy call by interested people. Many universities and research centers, including NGO from different countries world wide, following the recommendation of 'United Nations Scientific Committee on the Effects of Atomic Radiation' (USNCEAR) and 'International Commission on Radiological Protection ' (ICRP) until 1977, developed their own radon researches in order to clarify the properties, area distribution and concentration, geological production and other needed aspects. This paper compare the radon risk versus radioactive waste gaseous Nuclear Power Plant release in normal or abnormal operation and underlines the needs for Romanian's radiation research laboratories to undertake radon protection programs similar to to those underway in other countries. (authors)

  19. Radon surveys and their implications

    International Nuclear Information System (INIS)

    Miles, J.C.H.; Cliff, K.D.; Dixon, D.W.; Green, B.M.R.; Strong, J.C.

    1989-01-01

    In the UK, as in other countries, radon daughter inhalation is the most significant cause of human exposure to ionising radiation either at home or at work whether one considers the mean or the maximum dose. Substantial studies of radon are under way in the UK, and the importance of radon is recognised in several spheres. NRPB investigations of the radon levels in buildings and mines are reported, the distributions of doses presented and risk factors calculated. The bases of radon limitation for workers and members of the public are given and the means of compliance discussed. (author)

  20. Radon-222: tracer of geological systems dynamics. Methodology and signal processing, interpretation of radon-222 behaviour in active geological media

    International Nuclear Information System (INIS)

    Richon, Patrick

    2011-01-01

    Gases, especially radon, have often been cited as indicators of large-scale geodynamic processes, or as precursors of earthquakes and volcanic eruptions. Measurable in the air, water and rocks, natural radon concentrations are generally extremely low, because 1 Bq m -3 corresponds to a mixing ratio of 1,77 * 10 -20 in air at normal temperature and pressure (NPT). Expressed in a usual unit in chemistry of air pollution, an usual activity concentration of 37 Bq m -3 is only a billion th of ppb by volume (ppbv) in the atmosphere. Yet such, concentrations of radon are very easy to measure, because the decay α is an energetic phenomenon: It makes it theoretically possible to detect a single atom of radon, which is an inaccessible performance by chemical analysis. This feature, combined with a half-life of 3.82 days, makes radon so interesting for tracing natural phenomena. But the major drawback is that radon becomes very sensitive to subsurface meteorological and hydrogeological processes especially if the measurement methodology is not perfectly controlled. These aspects are not addressed in the past and in recent literatures and are rarely taken into account when analyzing and interpreting radon signal. We review these issues by addressing problems related to instrumentation, to measurement methods, and to data processing. We show how to extract signatures of geodynamical processes dissimulated in radon data for very different sites with strong dynamic like volcanic sites (La Soufriere of Guadeloupe, FWI, Merapi, Indonesia), tectonic sites (Syabru-Bensi in Nepal and the Kunlun fault in Tibet) and underground laboratories (Roselend and Argentiere). For this, we had to develop signals processing tools that allow us to extract the effect of barometric and gravimetric tide waves from the radon signal. This is a very sensitive for a detailed survey of the transport processes of radon that are closely linked to geodynamic processes involved in different sites. The

  1. A risk-based approach to health criteria for radon indoors -report on a WHO initiative

    International Nuclear Information System (INIS)

    Steinhaeusler, F.

    1994-01-01

    The World Health Organization (WHO), Regional Office for Europe, organised a meeting of a working group on indoor air quality in Eilat, Israel, from 28 March to 4 April 1993. The aim was to develop a risk-based approach to health criteria for radon indoors. The Group reviewed the latest epidemiological data from occupational and non-occupational radon exposure, animal experiments and dosimetry. The Group issued 14 conclusions and 23 recommendations on radon related risk to health, on risk management and risk communication. In summary, radon was confirmed as a human carcinogen. Indoor radon exposures resulting in individual risks exceeding 10 -3 per year are to be considered as severe and risk reduction programmes implemented. Guidance on risk management and communication is offered to national authorities. (author)

  2. Entry of soil gas and radon into houses

    International Nuclear Information System (INIS)

    Andersen, C.E.

    1992-04-01

    Entry of soil gas and radon into houses has been investigated by experiments conducted at radon test structures and numerical or analytical modelling. The numerical model solves the steady-state equations for Darcy flow of soil-gas and combined diffusive and advective transport of radon. Model calculations were compared with results from field experiments conducted at Risoe National Laboratory, and it was found that there was good agreement between measured and modelled pressure coupling and radon concentration profiles. Discrepancies regarding absolute values of soil-gas entry rates and radon concentrations were observed. The numerical model has been used to study the importance of soil and building related factors on radon entry rates into slab-on-grade houses. It was found that, for a house with a 3 mm perimeter crack along the floor-wall joint, the entry was mainly determined by the soil permeability and building related factors such as house depressurization and presence of a capillary breaking layer of gravel below the slab. In a house with a bare soil floor, the diffusivity of the soil was found to be of principal importance for the entry rate even for moderate permeabilities. An analytical model was developed for the purpose of studying soil-gas entry rates into houses in response to non-static driving forces. It is based on the analogy between a 'buried drain' and a basement house with a perimeter crack. The structure was depressurized sinusoidally in time and the frequency dependent pressure couplings were measured. There was fairly good agreement between theoretical and experimental results. (LN) (26 tabs., 30 ills., 66 refs.)

  3. Radon in soil gas survey in Curitiba (Brazil)

    International Nuclear Information System (INIS)

    Paschuk, Sergei A.; Correa, Janine Nicolosi; Schelin, Hugo R.; Barbosa, Laercio; Sadula, Tatyana; Matsuzaki, Cristiana A.

    2009-01-01

    This work describes the radon in soil gas measurements performed during the last two years in cooperation between the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR), the Nuclear Technology Development Center (CDTN) and the Institute of Radiation Protection and Dosimetry (IRD) from the Brazilian Nuclear Energy Commission (CNEN). Following previously concluded measurements of radon concentration in dwellings and the measurements of 222 Rn activity in drinking water collected at artesian bores of Curitiba urban area, present step of activities has been dedicated to measurements of radon concentration in soil gas. Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specially developed for such measurements Soil Gas Probe through the air pump and filter system. After the Probe was inserted, the ground has been tamped down around the probe, to prevent air from moving vertically along the outside of the shaft. The equipment was adjusted with air flow of 0.03 L/min and the measurements were performed during 90 min approximately. The 222 Rn concentration levels were detected and analyzed by the computer every 5 minutes using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222 Rn concentration were processed taking into account the internal volume of Soil Probe and connection vessels. Radon sampling was performed at a depth of 50 - 70 cm. Obtained experimental data of radon concentration present rather big variation but correlates perfectly with previously obtained results for 222 Rn activity in drinking water. Further measurements are planned to be performed at other regions of Parana State and will involve the mineral analysis of soil samples. (author)''

  4. Radon programmes and health marketing.

    Science.gov (United States)

    Fojtikova, Ivana; Rovenska, Katerina

    2011-05-01

    Being aware of negative health effects of radon exposure, many countries aim for the reduction of the radon exposure of their population. The Czech radon programme was commenced >20 y ago. Since then experts have gathered a lot of knowledge, necessary legislation has been enacted, tens of thousands of inhabitants have been offered free measurement and subsidy for the mitigation. Despite the effort, the effectiveness of the radon programme seems to be poor. Newly built houses still exhibit elevated radon concentrations and the number of houses mitigated is very low. Is it possible to enhance the effectivity of radon programme while keeping it on a voluntary basis? One possible way is to employ health marketing that draws together traditional marketing theories and science-based strategies to prevention. The potential of using marketing principles in communication and delivery of radon information will be discussed.

  5. Evaluation of the performance characteristics of radon and radon-daughter concentration measurement devices under controlled environmental conditions

    International Nuclear Information System (INIS)

    Pearson, M.D.

    1989-04-01

    The Technical Measurements Center (TMC) conducted a study to expose 10 radon and 7 radon-daughter concentration measurement devices in the DOE/GJPO Radon/Radon-Daughter Environmental Chamber for a series of 24 controlled-environment tests. The tests evaluated the devices' response to temperature, relative humidity, dew point, condensation-nuclei concentration, radon-daughter/radon equilibrium ratio, and non-uniform radon and radon-daughter concentration. Devices were evaluated for linear response as a function of concentration. In addition to response to environmental parameters, the evaluation included determining the utility of the devices in providing reasonable assurance of compliance with the radon and radon-daughter concentration standards for DOE remedial action programs. This reasonable assurance criterion is based on a coefficient of variation of 25 percent for devices deployed for year-long measurements and a coefficient of variation of 18 percent for devices deployed for intermittent sampling. 39 refs., 65 figs., 33 tabs

  6. Radon levels in underground workplaces: a map of the Italian regions

    International Nuclear Information System (INIS)

    Rossetti, Marta; Esposito, Massimo

    2015-01-01

    The indoor radon exposition is a widely recognised health hazard, so specific laws and regulations have been produced in many countries and so-called radon-risk maps have consequently been produced. In Italy the regulation applies to general workplaces and a national survey was carried out in the 1990's to evaluate the exposure to radon in dwellings. Failing a national coordinated mapping programme, some Italian regions performed a survey to identify radon-prone areas, nevertheless with different methodologies. In this work a national map of the average annual radon concentration levels in underground workplaces, obtained from the results of 8695 annual indoor radon measurements carried out by U-Series laboratory between 2003 and 2010, was presented. Due to underground locations, the mean radon concentration is higher than that from previous map elaborated for dwellings and a significant radon concentration was also found in Regions traditionally considered as low-risk areas. (authors)

  7. Measure of exposure of short-lived radon products using an alpha spectrometer for measuring indoor aerosol activity concentration and dose evaluation

    International Nuclear Information System (INIS)

    Berico, M.; Castellani, C. M.; Formignani, M.; Mariotti, F.

    2001-01-01

    A new italian law introduces the regulation of occupational exposure to radon. To evaluate the inhalation of radon daughters by the workers a sampling device has been assembled with the aim of evaluation of unattached and aerosol attached radon daughters' fractions. The instrument, based on selection of the aerosuspended particles by means of a wire screen type battery and subsequent collection on a total filter, allows to describe the behaviour of both fractions using defined temporal pattern of collecting particles and counting them by alpha spectroscopy. A measurement campaign to test the radon daughter dichotomous spectrometer in comparison with a commercial Radon Working Level meter, has been performed in a research laboratory of central Italy affected by high radon concentrations. The radon concentration during the measurement campaign has been also measured. The equilibrium factor F e q ad the attachment factor fp have been evaluated during 3 days campaign. Using the measured mean parameters (radon concentration, F e q, f p ) the dose evaluation for workers using dosimetric approach has been performed. A comparison between the epidemiologic approach, based on the radon concentration, and dosimetric approach is also presented [it

  8. Airborne radon-222 measurement by active sampling with charcoal adsorption and gamma-ray spectrometry

    International Nuclear Information System (INIS)

    Shizuma, Kiyoshi; Wen, Xiao-qiong; Fukami, Kenji; Iwatani, Kazuo; Hamanaka, Shun-ichi

    1998-01-01

    A simple method for measuring radon concentration in air is presented. Airborne radon is adsorbed in a charcoal bed by an active air sampling. In time, the adsorbed radon comes to attain radioactive equilibrium with its short-lived progeny 214 Pb. Utilizing this fact, radon concentration is derived from γ-ray measurement of 214 Pb. This method is estimated to be capable of detecting radon concentration in air down to 0.79 Bq·m -3 . The adsorption coefficient obtained with the method is compared with what is obtainable with passive sampling. Applications of this method to indoor and outdoor radon measurements are described. (author)

  9. Costs of radon diagnostics and mitigation in school building

    International Nuclear Information System (INIS)

    Leovic, K.W.; Rector, H.; Nagda, N.

    1992-01-01

    To determine the costs of radon diagnostics and active soil depressurization (ASD) system installation in schools, seven radon mitigators with extensive experience in school buildings were surveyed. The cost data were determined by providing the mitigators with two scenarios of open-quotes typicalclose quotes school buildings with elevated radon levels. The questionnaire in schools: (1) Review Construction Plans, (2) Conduct Diagnostic Measurements, (3) Design Mitigation System, (4) Purchase ASD Material, and (5) Install and Checkout ASD System. Based on the results of this survey, it is estimated that the average cost of ASD diagnostics and mitigation in a typical school would be roughly $0.50 per ft 2 . However, these costs would be higher in schools with extensive subslab walls, very poor PFE, and lower in simple schools with very good PFE and no subslab barriers to communication. The variations in costs provided by the mitigators are primarily due to the influences of (1) experience and practices of the mitigation companies, (2) ASD system requirements as perceived by the respondents, and (3) the degree of involvement by the school system in the process

  10. Methodology developed to make the Quebec indoor radon potential map

    Energy Technology Data Exchange (ETDEWEB)

    Drolet, Jean-Philippe, E-mail: jean-philippe.drolet@ete.inrs.ca [Institut national de la recherche scientifique, Eau Terre Environnement Research Centre (ETE-INRS), 490 de la Couronne, G1K 9A9 Quebec (Canada); Martel, Richard [Institut national de la recherche scientifique, Eau Terre Environnement Research Centre (ETE-INRS), 490 de la Couronne, G1K 9A9 Quebec (Canada); Poulin, Patrick [Institut national de santé publique du Québec (INSPQ), 945 avenue Wolfe, G1V 5B3 Quebec (Canada); Dessau, Jean-Claude [Agence de la santé et des services sociaux des Laurentides, 1000 rue Labelle, J7Z 5 N6 Saint-Jérome (Canada)

    2014-03-01

    This paper presents a relevant approach to predict the indoor radon potential based on the combination of the radiogeochemical data and the indoor radon measurements in the Quebec province territory (Canada). The Quebec ministry of health asked for such a map to identify the radon-prone areas to manage the risk for the population related to indoor radon exposure. Three radiogeochemical criteria including (1) equivalent uranium (eU) concentration from airborne surface gamma-ray surveys, (2) uranium concentration measurements in sediments, (3) bedrock and surficial geology were combined with 3082 basement radon concentration measurements to identify the radon-prone areas. It was shown that it is possible to determine thresholds for the three criteria that implied statistically significant different levels of radon potential using Kruskal–Wallis one way analyses of variance by ranks. The three discretized radiogeochemical datasets were combined into a total predicted radon potential that sampled 98% of the studied area. The combination process was also based on Kruskal–Wallis one way ANOVA. Four statistically significant different predicted radon potential levels were created: low, medium, high and very high. Respectively 10 and 13% of the dwellings exceed the Canadian radon guideline of 200 Bq/m{sup 3} in low and medium predicted radon potentials. These proportions rise up to 22 and 45% respectively for high and very high predicted radon potentials. This predictive map of indoor radon potential based on the radiogeochemical data was validated using a map of confirmed radon exposure in homes based on the basement radon measurements. It was shown that the map of predicted radon potential based on the radiogeochemical data was reliable to identify radon-prone areas even in zones where no indoor radon measurement exists. - Highlights: • 5 radiogeochemical datasets were used to map the geogenic indoor radon potential. • An indoor radon potential was determined for

  11. Evaluation of the open vial method in the radon measurement

    International Nuclear Information System (INIS)

    Lopez del Rio, H.; Davila R, J. I.; Mireles G, F.

    2014-10-01

    The open vial method is a simple technique, under-utilized but that take advantage of the great radon solubility in organic solvents, therefore applies in the measurement of the radon concentration exhaled in soil. The method consists on the exposition to the gas radon of an open vial with scintillating solution. An integral mathematical model for indoors that describes the emanation processes and gas radon exhalation was developed, as well as the radon dissolution in the scintillation liquid, besides obtaining the characteristic parameters of the experimental system proposed for the radon concentration calculation exhaled by soils. Two experimental arrangements were designed with exposition cameras of 12 and 6 L and quantity of different soil. The open vial was prepared with a mixture of 8 ml of deionized water and 12 ml of scintillation liquid OptiPhase Hi Safe 3 in polyethylene vials; the measurements of the dissolved radon were carried out in scintillation liquid equipment. As a result, on average 2.0% of the exhaled radon is dissolved in the open vial and the dissolved fraction is independent of the experimental arrangement. Also was observed that the exposition time does not affect the radon dissolution significantly, in correspondence with the reported in the literature. (Author)

  12. Improvements in radon retrospective assessments based on analysis of 210Po embedded in glasses

    International Nuclear Information System (INIS)

    Trotti, F.; Lanciai, M.; Mozz, P.; Panepinto, V.; Poli, S.; Predicatori, F.; Righetti, F.; Tacconi, A.; Tanferi, A.

    1998-01-01

    In epidemiological studies into the connection between lung cancer and indoor radon, an important uncertainty factor comes from the assessment of radon exposure. Past radon concentrations can be estimated from measurements of 210 Po embedded in surfaces in the dwellings. In the paper the technique is highlighted based on 210 Po detection using CR-39 detectors applied to glass surfaces and on subsequent spectroscopic analysis with an image analyzer. Actual application of the technique is described and examples of the results are presented. (A.K.)

  13. Radon programmes and health marketing

    International Nuclear Information System (INIS)

    Fojtikova, I.; Rovenska, K.

    2011-01-01

    Being aware of negative health effects of radon exposure, many countries aim for the reduction of the radon exposure of their population. The Czech radon programme was commenced >20 y ago. Since then experts have gathered a lot of knowledge, necessary legislation has been enacted, tens of thousands of inhabitants have been offered free measurement and subsidy for the mitigation. Despite the effort, the effectiveness of the radon programme seems to be poor. Newly built houses still exhibit elevated radon concentrations and the number of houses mitigated is very low. Is it possible to enhance the effectivity of radon programme while keeping it on a voluntary basis? One possible way is to employ health marketing that draws together traditional marketing theories and science-based strategies to prevention. The potential of using marketing principles in communication and delivery of radon information will be discussed. (authors)

  14. Measurement of radon, radon daughters and thoron concentrations by multi-detector devices. No. E/12

    International Nuclear Information System (INIS)

    Somogyi, G.; Varga, Zs.

    1983-01-01

    There is a growing interest in collection of data concerning human exposures to naturally occurring alpha-emitting radionuclides (e.g. in mines, dwellings, building materials, industrial wastes, coal fuel cycle, water supply, soil, plants, etc.). Most of such studies are incomplete for the following reasons: in radon measurements the contribution of thoron is generally neglected, the determination of equilibrium factor is complicated or not possible at all, short- and long-term concentration fluctuations cause difficulties in obtaining representative mean values, the plate-out effect is generally not taken into account. A variety of simple methods were studied that could be used to overcome some of these difficulties by using cups equipped with two or more alpha-sensitive nuclear track detectors. A theoretical foundation of the quantitative measurements with such devices is presented. Experimental data are reported on radon, radon daughters and thoron concentrations measured by multi-detector devices in cave soil gas and in air of Hungarian dwellings. (author)

  15. Development of a model for radon concentration in indoor air

    International Nuclear Information System (INIS)

    Jelle, Bjørn Petter

    2012-01-01

    A model is developed for calculation of the radon concentration in indoor air. The model takes into account various important parameters, e.g. radon concentration in ground, radon diffusion resistance of radon barrier, air permeance of ground, air pressure difference between outdoor ground and indoor at ground level, ventilation of the building ground and number of air changes per hour due to ventilation. Characteristic case studies are depicted in selected 2D and 3D graphical plots for easy visualization and interpretation. The radon transport into buildings might be dominated by diffusion, pressure driven flow or a mixture of both depending on the actual values of the various parameters. The results of our work indicate that with realistic or typical values of the parameters, most of the transport of radon from the building ground to the indoor air is due to air leakage driven by pressure differences through the construction. By incorporation of various and realistic values in the radon model, valuable information about the miscellaneous parameters influencing the indoor radon level is gained. Hence, the presented radon model may be utilized as a simple yet versatile and powerful tool for examining which preventive or remedial measures should be carried out to achieve an indoor radon level below the reference level as set by the authorities. - Highlights: ► Model development for calculation of radon concentration in indoor air. ► Radon model accounting for various important parameters. ► Characteristic case studies depicted in 2D and 3D graphical plots. ► May be utilized for examining radon preventive measures.

  16. Control of radon in Finnish workplaces

    International Nuclear Information System (INIS)

    Markkanen, M.

    2002-01-01

    Natural radiation in Finland is regulated in the Finnish Radiation Act from 1992. Occupational exposure to natural radiation is regulated by an amendment of the Radiation Decree in 1998. The most important issues in Finland are radon in workplaces, radioactivity in drinking water and in building materials, and mining and industrial processes. Radon levels in mines have been measured regularly since 1972. Finland has an action level for radon in workplaces of 400 Bq/m 3 . Radon prone areas have been identified primarily from measurements of radon in dwellings. Radon measurements are compulsory in workplaces in radon prone areas unless it can be shown by other means that radon levels are low. A programme focusing on radon in workplaces was initiated in 1992. To date, radon measurements have been carried out in 10,000 workplaces and remedial actions have been taken in 200 of these. The average reduction in radon concentration in remediated buildings is about 1,500 Bq/m 3 . Identification of NORM industries is based on the radionuclide content of the materials used (>1.4 Bq/g U and >0.4 Bq/g Th). The occupational exposure should not exceed 1 mSv/y (excluding radon)

  17. THE REPUBLIC OF BELARUS RADON DANGER MAP

    Directory of Open Access Journals (Sweden)

    L. A. Chunikhin

    2016-01-01

    Full Text Available Radon is the major contributor to the background exposure of the population. In the world practice, the radon risk or radon potential mapping are used for the radon dose assessment.The aim of this work was a radon danger mapping of the Republic of Belarus to assess the radiation situation and determine the radon hazard critical areas.Materials and methods: The mapping is based on measured values of radon volume activity in the living rooms of different buildings on the territory of the six regions of the Republic of Belarus. We have performed more than 4000 measurements. Integral track radon radiometers based on the polymer Kodak LR-115 film were used to evaluate radon volume activity. Exposure time ranged from 90 to 120 days. The cartogram was built with using the MAPINFO software package.Results: The low levels of radon concentrations were determined in the Brest and Gomel regions, as well as in the southern districts of Minsk and south-western districts of the Mogilev region. The high levels radon concentrations were determined in some districts of the Vitebsk and Grodno regions, as well as in the north-eastern districts of the Mogilev region. About 2–5 times nonuniformity of radon distribution in settlements of the Republic was observed. The radon hazard critical areas with radon concentrations in the range of 200–400 Bq/m3 were found in some districts of the Vitebsk, Grodno and Mogilev regions.Conclusions: The radon risk map of the Republic of Belarus gives the possibility to estimate the existing radiation risk. Taking into account the low efficiency of countermeasures long after the Chernobyl accident, it is necessary to increase the level of radiation protection through the radon mitigation activities or to change the radon normative documents.

  18. Radon in large buildings

    International Nuclear Information System (INIS)

    Wilson, D.L.; Dudney, C.S.; Gammage, R.B.

    1993-01-01

    Over the past several years, considerable research has been devoted by the U.S. Environmental Protection Agency (USEPA) and others to develop radon sampling protocols for single family residences and schools. However, very little research has been performed on measuring radon in the work place. To evaluate possible sampling protocols, 833 buildings throughout the United States were selected for extensive radon testing. The buildings tested (warehouses, production plants and office buildings) were representative of commercial buildings across the country both in design, size and use. Based on the results, preliminary radon sampling protocols for the work place have been developed. (orig.). (5 refs., 3 figs.)

  19. Residential radon daughter monitor based on alpha spectroscopy

    International Nuclear Information System (INIS)

    Nazaroff, W.W.

    1980-05-01

    The radioactive daughters of radon-222 pose a serious indoor air quality problem in some circumstances. A technique for measuring the concentrations of these radioisotopes in air is presented. The method involves drawing air through a filter; then, for two time intervals after sampling, counting the alpha decays from polonium-218 and polonium-214 on the filter. The time intervals are optimized to yield the maximum resolution between the individual daughter concentrations. For a total measurement time of 50 minutes, individual daughter concentrations of 1.0 nanocuries per cubic meter are measured with an uncertainty of 20%. A prototype of a field monitor based on this technique is described, as is a field test in which the prototype was used to measure radon daughter concentrations as a function of ventilation conditions in an energy-efficient house

  20. Influence of environmental changes on continuous radon monitors. Results of a Spanish intercomparison exercise

    International Nuclear Information System (INIS)

    Vargas, A.; Ortega, X.

    2006-01-01

    The first Spanish intercomparison exercise for continuous radon monitors was carried out with the participation of nine monitoring systems from eight laboratories. The exposures were carried out in the radon and thoron chambers at the Inst. of Energy Techniques (INTE) of the Technical Univ. of Catalonia (UPC), which is considered to be the Spanish reference chamber. The monitors were exposed to three different temperatures (13, 20 and 30 deg. C), relative humidities (30, 45 and 80%) and radon concentrations (450, 2000 and 9000 Bq m -3 ). Exposures in the thoron chamber were carried out at concentrations of ∼450 Bq m -3 . The response of the ionisation chambers and scintillation monitors was acceptable. However, the response of monitors based on electrostatic collection was found to be influenced by external climatic conditions. Moreover, all radon monitors were sensitive to thoron concentration, which was especially significant for scintillation monitors. (authors)

  1. Radon

    Science.gov (United States)

    ... radon-resistant features. These features include gravel and plastic sheeting below the foundation, along with proper sealing ... lower the radon level. Detailed information about radon reduction in your home or building can be found ...

  2. Experimental and theoretical study of radon levels in a house

    Energy Technology Data Exchange (ETDEWEB)

    Ameon, R.; Dupuis, M.; Marie, L.; Diez, O.; LionS, J. [Institute for Radiological Protection and Nuclear Safety, Fontenay-aux-roses (France); Tymen, G. [LARAAH, Universite de Bretagne Occidentale, Brest (France)

    2006-07-01

    Full text of publication follows: Radon being a radioactive gas of natural origin is omnipresent everywhere at the surface of earth. It is created by the radium decay issued from the uranium contained in the earth crust and more specifically in granitic and volcanic subsoils. Because of the dilution due to air masses, its concentration in open air is low. On the other hand, radon may accumulate in the confined atmosphere of buildings and achieve high concentration levels. Across France, it has been estimated that 300 000 individual dwellings present concentration higher than the French reference level of 400 Bq.m{sup -3} and that 60 000 other ones would exhibit concentration above 1 000 Bq.m{sup -3}, the French warning threshold. Indoor radon concentration may vary significantly for various reasons, including design of buildings, radium content and texture of the soil in contact with the building's slab and walls, the under pressure value between the inside and outside and the fresh air supply rate. These considerations have led the I.R.S.N. to develop a code called R.A.D.O.N. 2 for conducting simple and methodical studies of indoor radon concentrations, to take into account the above-mentioned factors. But, the achievement of an effective diagnosis and risk management -aiding tool requires to first check its validity on the phenomenological model at the origin of the code. A 3-year experimental follow-up was, thus, conducted within an unoccupied house built on an uranium-bearing geological formation. After characterization of the subsoil, the instrumentation was implemented on site to continuously monitor the following parameters: - the radon source term in the building (exhalation rate of {sup 222}Rn at the ground/building interface and at soil surface, radon concentration at the soil and in outdoor air), - the radon penetration by advection (differential pressure in the house basement), - the driving mechanisms for natural ventilation in the house (weather

  3. Experimental and theoretical study of radon levels in a house

    International Nuclear Information System (INIS)

    Ameon, R.; Dupuis, M.; Marie, L.; Diez, O.; LionS, J.; Tymen, G.

    2006-01-01

    Full text of publication follows: Radon being a radioactive gas of natural origin is omnipresent everywhere at the surface of earth. It is created by the radium decay issued from the uranium contained in the earth crust and more specifically in granitic and volcanic subsoils. Because of the dilution due to air masses, its concentration in open air is low. On the other hand, radon may accumulate in the confined atmosphere of buildings and achieve high concentration levels. Across France, it has been estimated that 300 000 individual dwellings present concentration higher than the French reference level of 400 Bq.m -3 and that 60 000 other ones would exhibit concentration above 1 000 Bq.m -3 , the French warning threshold. Indoor radon concentration may vary significantly for various reasons, including design of buildings, radium content and texture of the soil in contact with the building's slab and walls, the under pressure value between the inside and outside and the fresh air supply rate. These considerations have led the I.R.S.N. to develop a code called R.A.D.O.N. 2 for conducting simple and methodical studies of indoor radon concentrations, to take into account the above-mentioned factors. But, the achievement of an effective diagnosis and risk management -aiding tool requires to first check its validity on the phenomenological model at the origin of the code. A 3-year experimental follow-up was, thus, conducted within an unoccupied house built on an uranium-bearing geological formation. After characterization of the subsoil, the instrumentation was implemented on site to continuously monitor the following parameters: - the radon source term in the building (exhalation rate of 222 Rn at the ground/building interface and at soil surface, radon concentration at the soil and in outdoor air), - the radon penetration by advection (differential pressure in the house basement), - the driving mechanisms for natural ventilation in the house (weather conditions, indoor

  4. The radon

    International Nuclear Information System (INIS)

    1998-01-01

    This booklet is intended to answer briefly the most important questions about the nature and sources of radon, its pathways from environment to organism, as well as the ways to minimize its concentration in the habitat's atmosphere. The radon is a naturally appearing radioactive gas, produced through the decay of uranium and radium present in the terrestrial crust. It can be found everywhere on the planet's surface and it is emitted particularly from the granite and volcanic underground rocks as well as from certain construction materials. It is one of the agents producing pulmonary cancer, although not so dangerous as the tobacco is. The following items are elaborated in this booklet: - the place of radon in the average exposure to ionizing radiations of the French population; - the risk; - the radon in the environment (the meteorological conditions, the nature of the rocks); - radon in dwellings (radon measurements in the French dwellings, the entrance pathways of radon, the dependence of radon concentration on the profession and way of life of the inhabitants); - radon measurements; - how to reduce the radon concentration in dwellings

  5. Molecular and cytogenetic characterization of radon-induced lung tumors in the rat

    International Nuclear Information System (INIS)

    Dano, Laurent

    2000-01-01

    Radon is a natural radioactive gas. This radioelement, which is an α-particle emitter, is omnipresent in the environment. Inhalation of atmospheric radon is the major exposure route in man of natural radioactivity which results in respiratory tract contamination. An increased lung cancer risk associated with radon inhalation has been shown both in humans and animals by epidemiological and experimental studies, respectively. In rats, characterization of dose-effect relationships has led to the construction of statistical models that may help theoretically in the prediction of human health involvements of both occupational and domestic chronic exposure to radon. However, little is known about the cellular and molecular mechanisms of radon-induced lung carcinogenesis. In the laboratory, a model of lung cancers induced in rats after radon inhalation is available. This model represents a good tool to identify and characterize the genetic events contributing to the development of radon-induced lung tumors. Carrying out a global approach based on the combined use of classical and molecular cytogenetic methods, the analysis of 17 neoplasms allowed the identification of chromosomal regions frequently altered in these tumors. Numerous similarities have been found between our results and the cytogenetic data for human lung cancers, suggesting common underlying genetic molecular mechanisms for lung cancer development in both species. Moreover, our study has allowed to point to tumor suppressor genes and proto-oncogenes potentially involved in radon-induced lung carcinogenesis. Thus, our results may aid further molecular studies aimed either at confirming the role of these candidate genes or at demonstrating the involvement of yet to be identified genes. (author) [fr

  6. The sensitivity to humidity of radon monitoring instruments

    International Nuclear Information System (INIS)

    Schmied, H.

    1984-01-01

    In a project funded by the Swedish Building Research Council (BFR) a continuous radon monitoring instrument (RGA-400 EDA Instr. Inc.) with electrostatic field collection has been calibrated. The original calibration factor gave no reliable radon readings and was therefore corrected for relative humidity by EDA. From four calibrations in the radon chamber at the Swedish Radiation Protection Board (SSI) it was clear that the instrument was sensitive to absolute humidity, which gave better agreement than relative humidity or temperature. Sensitivity to humidity for this principle of measure ment has been presented in various papers without presenting any combined influence with temperature, which can lead to the wrong conclusions, especially when the temperature levels differ. Some laboratories use humidity absorbants to overcome this humidity dependence. In this paper the calibration results for the FGA-400 radon readings only, are presented. (Author)

  7. Radon in homes and other technologically enhanced radioactivity

    International Nuclear Information System (INIS)

    Rundo, J.; Toohey, R.E.

    1983-01-01

    The results are described of recent observations at Argonne National Laboratory, contributing to our knowledge of such factors as the origin of high levels of radon in houses, its variability with time or otherwise, its uniformity throughout the house or otherwise, and the behavior and fate of the short-lived daughter-products. In a sample of 110 houses, mostly in the west suburban area of Chicago, 15% had radon concentrations in excess of 6 pCi litre - 1 and 96% greater than 10 pCi litre - 1 . If this distribution is representative of all houses in the USA, the population being exposed to such high concentrations of radon is far greater than the number of people in Grand Junction being exposed to quite similar concentrations from technologically enhanced radioactivity. There is a great need for far more extensive data on radon in houses

  8. Radon dynamics in underwater thermal radon therapy

    International Nuclear Information System (INIS)

    Lettner, H.; Hofmann, W.; Winkler, R.; Rolle, R.; Foisner, W.

    1998-01-01

    At a facility for underwater thermal radon therapy in Bad Hofgastein, experiments were carried out with the aim of establishing radon in the air exhaled by the treated patients and of radon decay products on the skin of the patients. The time course of radon concentration in the exhaled air shows a maximum a few minutes after entering the bath, then the Rn concentration remains constant over the remaining time spent in the bath. Taking into account several simplifying assumptions, the average dose to the epidermis from radon daughters is about 50 μGy. (A.K.)

  9. Indoor radon measurements in Adelaide, South Australia

    International Nuclear Information System (INIS)

    Paix, D.

    1989-01-01

    In 1986 a study of radon levels in homes in Melbourne was made, using activated charcoal to adsorb the gas from indoor air. Cups containing 25g of activated charcoal were exposed for periods of nominally 7 days. The cups were sealed and the accumulated activity was measured by gamma counting. Cup activity was related to ambient radon concentration by calibrations done in the Australian Radiation Laboratory's radon reference chamber. This work was continued in Adelaide, South Australia (S.A.) between July and November 1986 using the same methods. Cups were exposed in their homes by 213 volunteers from the staff of the S.A. Institute of Technology and the S.A. Health Commission. The median concentration of radon in air was 10 Bq/m 3 , with 90% of values below 35 Bq/m 3 , and 100% below 75 Bq/m 3 . The lower bound of the distribution is poorly defined because of inadequate counting statistics. 4 refs., 6 figs

  10. Efficient measurement of radon daughters

    International Nuclear Information System (INIS)

    Rolle, R.

    1992-01-01

    In environmental control there is an increasing need for efficient measurement of radon and thoron daughters in air. Measuring instruments should be rugged and portable for field use, while also permitting unattended operation for several days. Simple operating procedures should permit evaluation of rapidly changing concentrations over extended periods. These requirements demand careful balance in the design of hardware and measuring procedures. The design principles for a continuous flow-through spectrometer, that has been developed for precision sequential measurement of radon and thoron daughters, are described. Because of the high precision of measurement, this type of instrument should find application in environments from technologically enhanced natural radiation to the very lowest natural background situations. (author)

  11. Radon in Schools

    Science.gov (United States)

    ... Search Search Radon Contact Us Share Radon in Schools Related Information Managing Radon in Schools Radon Measurement ... Radon Could Be a Serious Threat to Your School Chances are you've already heard of radon - ...

  12. Radiation exposure in homes through radon and thoron daughter products

    International Nuclear Information System (INIS)

    Schmier, H.

    1984-01-01

    In a random selection of about 6000 homes in the Federal Republic of Germany, the radon concentration in room air has been measured using a simple dosemeter developed by Karlsruhe Nuclear Research Centre. The mean radon concentration has been determined to be approximately 40-50 Bqu/m 3 . If this experiment is taken as a representative survey for the FRG, the mean dose contributed by the natural radiation exposure through radon and its short-lived decay products to the effective annual dose to the lungs can be computed to be about 1 mSv (100 mrem), using the internationally accepted conversion factors. Apart from this survey, special radon measuring programmes have been carried out, including simultaneous recording of meteorological data, in order to obtain information on the parameters to be taken into account when describing the daily variations of radon concentrations. (orig./DG) [de

  13. Radon in houses due to radon in potable water

    International Nuclear Information System (INIS)

    Hess, C.T.; Korsah, J.K.; Einloth, C.J.

    1987-01-01

    Radon concentration in the air of 10 houses has been measured as a function of water use and meterological parameters such as barometric pressure, wind velocity and direction, indoor and outdoor temperature, and rainfall. Results of calibrations and data collected in winter, spring, fall, and summer are given for selected houses. Average values of radon concentration in air are from 0.80 to 77 rhoCi/1. Water use average ranges from 70 to 240 gal/day. Average potential alpha energy concentrations in these houses range from 0.02 to 1.6 working levels. The radon level due to water use ranges from 0 to 36% of the house radon from soil and water combined. The radon level change due to use of a filter on the water supply shows a 60% reduction in radon in the house. Conclusions are that water radon can be a major fraction of the radon in houses. The ratio of airborne radon concentration due to water use to the radon concentration in water is 4.5 x 10/sup -5/ - 13 x 10/sup -5/

  14. Comparing summer and winter indoor radon and radon daughters activity in Campinas, Brazil

    International Nuclear Information System (INIS)

    Guedes, O.S.; Hadler, N.J.C.; Iunes, P.J.; Neman, R.S.; Souza, W.F.; Tello, S.C.A.; Paulo, S.R.

    2002-01-01

    We developed a technique - based on alpha particle track detection using CR-39 - where the activity originated from indoor radon can be potentially separated into three fraction: (i) radon in the air, (ii) radon daughters (RD), 218 Po and 214 Po, in the air and (iii) RD plated-out on the detector surface during exposure. In this work only a partial separation was carried out, then our results are limited to radon plus RD in the air and RD attached to detector surface. These activities can be separated if size and gray level of the round tracks are measured using an automatic optical microscopy system.Our group carried out an indoor radon and radon daughters (RD) survey in Campinas made up by a summer (November, 96 to May, 97) and a winter (May, 97 to November, 97) exposure, where the detectors were placed in the same rooms of the same dwellings (approximately 100) in both cases. Comparing winter and summer alpha activity for the detectors analyzed up to now, approximately 45 dwellings, we observed that: i) it seems that the source of radon is the material (brick and concrete mainly) making up walls, floor and ceiling of the dwellings, ii) there is no clear relationship between intensity of aeration and the activities measured in this work, and iii) the average ratio between winter and summer activity in the air (radon plus RD) is approximately equal to similar ratios observed in other countries, but for radon only. (author)

  15. Risk of lung cancer in animals following low exposures to Radon-222 progeny

    International Nuclear Information System (INIS)

    Duport, P.; Monchaux, G.; Morlier, J.P.

    1997-01-01

    Owing to the facts that a) large uncertainties affect the epidemiology of radon progeny-induced lung cancer in humans (especially at low exposures), and b) the rat is a good model for studying the carcinogenicity of radon progeny in humans, the risk of lung cancer following low exposures to low concentrations of radon progeny can be estimated from data obtained in the laboratory on rats exposed under controlled conditions. From the limited set of laboratory data on the induction of lung cancer in laboratory rats it appears that, at low exposures, the risk of lung cancer decreases with decreasing concentration, and that exposures of the order of 25 WLM, at an exposure rate of 2 WL do not produce any excess lung cancers. Since 20 WLM is a lifetime exposure comparable to those expected in occupational or indoors conditions and 2 WL is an exposure rate about 20 times higher dm current occupational exposures rates and 100 times higher than indoor ones, these observations may be indicative of threshold conditions for the induction of lung cancer by radon progeny. (author)

  16. Animals exposed to radon

    International Nuclear Information System (INIS)

    Masse, R.; Morin, M.; Lafuma, J.; Morlier, J.P.; Chameaud, J.; Bredon, P.

    1992-01-01

    'There is sufficient evidence that 222 Rn is a carcinogen in animals': this statement was important for the classification of radon as carcinogenic to man, outside of uranium mine atmospheres, clearly identified by epidemiology as causing lung cancer. Since recent reviews of animal experiments have been given by NCRP and by IARC, this review will be mainly limited to the recent results which came from two laboratories in the last 20 years. Battelle Pacific Northwest Laboratories (PNL), USA, and COGEMA Laboratoire de Pathologie Professionnelle (LPP) France. (author)

  17. Contribution of radon and radon daughters to respiratory cancer

    International Nuclear Information System (INIS)

    Harley, N.; Samet, J.M.; Cross, F.T.; Hess, T.; Muller, J.; Thomas, D.

    1986-01-01

    This article reviews studies on the contribution of radon and radon daughters to respiratory cancer and proposes recommendations for further research, particularly a national radon survey. The steady-state outdoor radon concentration averages 200 pCi/m3, and indoor levels are about 4 times higher. The primary source of radon in homes is the underlying soil; entry depends on multiple variables and reduced ventilation for energy conservation increases indoor radon levels. Occupational exposures are expressed in units of radon daughter potential energy concentration or working level (WL). Cumulative exposure is the product of the working level and the time exposed. The unit for cumulative exposure is the working level month (WLM). The occupational standard for radon exposure is 4 WLM/year, and 2 WLM/year has been suggested as a guideline for remedial action in homes. Epidemiologic studies show that miners with cumulative radon daughter exposures somewhat below 100 WLM have excess lung cancer mortality. Some 3% to 8% of miners studied have developed lung cancer attributable to radon daughters. All of the underground mining studies show an increased risk of lung cancer with radon daughter exposure. All cell types of lung cancer increased with radon exposure. If radon and smoking act in a multiplicative manner, then the risk for smokers could be 10 times that for nonsmokers. The potential risk of lung cancer appears to be between 1 and 2 per 10,000/WLM, which yields a significant number of lung cancers as some 220 million persons in the United States are exposed on average to 10 to 20 WLM/lifetime

  18. Low-level radon measurements by nuclear track detectors

    International Nuclear Information System (INIS)

    Koksal, E. M.; Goksel, S. A.; Alkan, H.

    1985-01-01

    In the work to be described here we have developed a passive nuclear track dosimeter to measure the integrated value of indoor radon (Rn-222) over a long period of time. Passive radon dosimeter which we have developed in our laboratories makes use of two small pieces of CR-39 plastic (Allyl diglycol carbonate) as detectors for registering tracks of alpha particles emitted by radon. These CR-39 plastic detectors are fixed on the inside bottom of a cup-shaped polystrene enclosure which is closed at the top by a tissue permeable for gases only. CR-39 detectors exposed to radon gas in the indoor air for a period of six months then are removed and chemically etched to make the alpha particle tracks visible under the microscope. The counts of tracks are evaluated to determine the radon concentration in the air in comparison with the number of tracks produced by a known concentration of radon gas. By using the passive dosimeters developed and the chemical etching procedure descriped here, measurements of indoor radon concentrations were carried out in 45 houses in different districts of the city of Istanbul. In this pilot experiment mean radon concentrations between 0.7 and 3.5 pCi/l have been found in these houses. In order to improve the counting of alpha tracks produced on the detectors a prototype electrochemical etching system in addition to chemical etching, is being developed. (author)

  19. Reducing radon daughter background in alpha continuous air monitors

    International Nuclear Information System (INIS)

    Rodgers, J.C.; McFarland, A.R.

    1991-01-01

    Alpha continuous air monitors are instruments designed to sample aerosols which may contain alpha-emitting radionuclides and, in near-real time, to monitor the sample for alpha emissions. This process is subject to interference from radon decay products. The usual method for overcoming this interference is by signal processing or data processing in such a manner as to accurately subtract a portion of the background from the transuranic count. An innovative alternative approach has been jointly developed in a collaboration between Los Alamos National Laboratory and Texas A ampersand M University. The concept is to attempt to physically remove a portion of the interfering radon daughters from the incoming sample by a diffusion screen before the sample is collected. The results of laboratory tests indicate that a very high removal efficiency for unattached radon progeny can be obtained without excessive loss of efficiency for collection of the contaminant aerosols of concern. 15 refs., 4 figs., 1 tab

  20. Use of radon-222 as tracer to estimate groundwater infiltration velocity in a river bank area

    International Nuclear Information System (INIS)

    Trinh Van Giap

    2003-01-01

    Naturally occurring isotope Rn-222 has been used as a natural tracer to determine the residence time of groundwater infiltrated from river into an aquifer in a riverbank area. The applied method is based on the increasing radon concentration in infiltrating water during it passes through the riverbank and reaches an equilibrium value. Solid-state nuclear track detector technique is used to measure directly radon concentration in water of a well. In order to confirm the relationship between radon concentration and it's residence time, a model was constructed in the laboratory. Experiment carried out in Nam Dinh are showed that mean infiltrating velocity of groundwater in the studied area as high as 5.1 m/day. (author)

  1. Radon in Estonian dwellings - Results from a National Radon Survey

    Energy Technology Data Exchange (ETDEWEB)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo [Estonian Radiation Protection Centre (Kiirguskeskus), Tallinn (Spain); Aakerblom, Gustav [Swedish Radiation Protection Authority, Stockholm (Sweden)

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m{sup 3}, in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m{sup 3}. In 1% of the dwellings the radon concentration exceeded 400 Bq/m{sup 3}. The highest radon concentration found in the study was 1040 Bq/m{sup 3}. Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m{sup 3}, and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m{sup 3}. The mean value for all Estonia dwellings is calculated

  2. Radon in Estonian dwellings - Results from a National Radon Survey

    International Nuclear Information System (INIS)

    Pahapill, Lia; Rulkov, Anne; Rajamaee, Raivo; Aakerblom, Gustav

    2003-10-01

    A countrywide survey of radon concentrations in Estonian dwellings was carried out during the period 1998-2001. The survey formed a part of the cooperation program on radiation protection between the Estonian Radiation Protection (Kiirguskeskus) Centre and the Swedish Radiation Protection Authority (SSI). The survey included measurements in a number of dwellings representative for Estonia in detached houses and multifamily buildings (only dwellings on the bottom floor were included in the survey). Altogether, radon concentrations were measured in 515 dwellings, a number large enough to be statistically significant. All measurements were made with alphatrack film detectors of the same type that SSI uses in Sweden. The measurements were made during a 2-3 month period during the winter half-year. Two detectors were used in each dwelling. In Estonia there are 0.17 million dwellings in detached houses and 0.45 million in multi apartment buildings. Of the 1.26 million inhabitants in Estonia. 0.36 million live in detached houses and 0.90 million in multi apartment buildings. Most of the latter were built during the Soviet occupation. Of the dwellings in multifamily buildings 30 % are assumed to be situated on the first floor. The mean radon concentration in dwellings in detached hoses, according to the survey results, is 103 Bq/m 3 , in dwellings on the bottom floor in multi apartment buildings it is 78 Bq/m 3 . In 1% of the dwellings the radon concentration exceeded 400 Bq/m 3 . The highest radon concentration found in the study was 1040 Bq/m 3 . Based on the assumption that the average radon concentration in the dwellings in multi-apartment buildings that are not situated on the bottom floor is 30 Bq/m 3 , and that these dwellings constitute 70% of all dwellings in multi apartment buildings, the mean radon concentration in dwellings in multi apartment buildings is calculated to be 44 Bq/m 3 . The mean value for all Estonia dwellings is calculated to be 60 Bq/m 3 . Using

  3. Radon and health

    International Nuclear Information System (INIS)

    Chobanova, Nina

    2016-01-01

    Radon is radioactive noble gas that can be found in soil, water, outdoor and indoor air. Since environmental radon on average accounts for about half of all human exposure to radiation from natural sources, increasing attention has been paid to exposure to radon and its associated health risks. Many countries have introduced regulations to protect their population from radon in dwellings and workplaces. In this article are discussed main characteristics of radon, including sources of exposure, variation in radon exposure, how managing risks from radon exposure, how to measure the concentration of radon. There are results of measurements conducted under the 'National radon programme' in Bulgaria also. Key words: radon, sources of exposure, risk, cancer, measure to decrease the concentration [bg

  4. Workshop on dosimetry for radon and radon daughters

    International Nuclear Information System (INIS)

    Turner, J.E.; Holoway, C.F.; Loebl, A.S.

    1978-05-01

    Emphasis is placed on the dosimetry for radon and daughters, rather than on monitoring and instrumentation. The objectives of the meeting were to exchange scientific information, to identify problem areas in radon-daughter dosimetry, and to make any observations or recommendations by the participants through issuance of this report. The discussion topics included the history of dosimetry for radon and daughters, human data, aerosols, deposition and movement in the respiratory tract, dose calculations, dose-to-working-level-month (WLM) conversion factors, animal experiments, and the development of regulations and remedial criteria for reducing population exposures to radon daughters. This report contains a summary of Workshop discussions plus individual statements contributed by several of the participants. The outstanding problem areas from the standpoint of dosimetry appear to involve the appropriate lung organ mass to be used (average lung-tissue dose vs. high-level local dose); recognition of the discrete, rather than continuous, structure of the mucus; lack of knowledge about lung clearance; the variability of dose with the degree of disequilibrium and the unattached fraction of radon daughters for a given WLM; and questions about the character of uranium mine atmospheres actually breathed in the older mines from which much of the epidemiological information originates. The development of criteria for taking remedial action to reduce exposures involves additional concerns of basing long-term risk assessment on short-term sampling and applying WLM data for miners to general populations

  5. Sealing Clay Text Segmentation Based on Radon-Like Features and Adaptive Enhancement Filters

    Directory of Open Access Journals (Sweden)

    Xia Zheng

    2015-01-01

    Full Text Available Text extraction is a key issue in sealing clay research. The traditional method based on rubbings increases the risk of sealing clay damage and is unfavorable to sealing clay protection. Therefore, using digital image of sealing clay, a new method for text segmentation based on Radon-like features and adaptive enhancement filters is proposed in this paper. First, adaptive enhancement LM filter bank is used to get the maximum energy image; second, the edge image of the maximum energy image is calculated; finally, Radon-like feature images are generated by combining maximum energy image and its edge image. The average image of Radon-like feature images is segmented by the image thresholding method. Compared with 2D Otsu, GA, and FastFCM, the experiment result shows that this method can perform better in terms of accuracy and completeness of the text.

  6. Uniformity in radon exhalation from construction materials using can technique

    Energy Technology Data Exchange (ETDEWEB)

    El-Amri, E.A.; Al-Jarallah, M.I. E-mail: mibrahim@kfupm.edu.sa; Abu-Jarad, F.; Fazal-ur-Rehman

    2003-06-01

    The uniformity in radon exhalation rates for 46 tiles of granite, marble and ceramic used as construction materials were determined using 'Can Technique' employing CR-39 nuclear track detectors (NTDs). On each tile, two sealed cans, each enclosing one NTD fixed at the center of the tile surface area covered by the can, were mounted at two different locations of each individual tiles. The track production rates on the NTDs representing radon exhalation rates were measured. The radon exhalation rates from the surface of individual tiles showed uniform exhalations within the calculated uncertainties of the measured values. This makes Can Technique an alternative simple method to measure radon exhalation rates. Calibration required to convert track production rates into radon exhalation rates for the used can and NTD was done using an active technique. The correlation between the measurements by the two techniques shows a good linear correlation coefficient (0.83)

  7. Predicting radon/radon daughter concentrations in underground mines

    International Nuclear Information System (INIS)

    Leach, V.A.

    1984-01-01

    A detailed description of a computer programme is outlined for the calculation of radon/radon daughter concentrations in air. This computer model is used to predict the radon/radon daughter concentrations in Working Level (WL) at the workplace and at the various junctions at either end of the branches in a typical ventilation network proposed for the Jabiluka mine in the Northern Territory

  8. The measure and control system of mini-type radon room based on PC104

    International Nuclear Information System (INIS)

    Zhou Shumin; East China Inst. of Technology, Fuzhou; Tang Bin; Sun Yamin

    2005-01-01

    Radon room is one of the standard equipment which demarcates radon measure instrument. The paper discusses the dynamic method and mathematic model which keeps the radon consistence stability in radon room. The system is developed on PC104. The system can monitor the radon consistence and replenishment radon according the radon control parameter. (authors)

  9. Modelling and experimental study of the behavior of radon and radon decay products in an enclosure. Application to houses

    International Nuclear Information System (INIS)

    Gouronnec, A.M.

    1995-01-01

    Since the eighties, more and more studies were performed about radon and its decay products in houses with one of the aim being the estimation of the dose received by their inhabitants. Then, the principal objective of this work is to describe the behaviour of radon and its decay products within a dwelling. In the first part to the report, a few definitions are given and data from literature give an idea of indoor radon and radon decay products activities and/or size distribution. Aspects of dosimetry are presented too. In the second part of the work, a mathematical model, called 'PRADDO' of Physic of Radon and radon Decay products in Domestic environment is developed on the basis of the classical model written by Jacobi in 1972. On the one hand, it has to predict radon decay products activities in systems consisting in one or more enclosure(s), from radon activity and from ambient aerosol concentration and size distribution. On the other hand, one part of the model is assigned to study the influence of the entry model parameters variation on the calculated quantities. Then, in the third part of the work, two experimental studies are realised in order to compare measurements to modelization. The first experimentation is a laboratory work, made on the test bench ICARE from IPSN, and the second one consists in describing the basement of an occupied house from Brittany. In the two cases, the comparison between experiments and modelling shows a good agreement if particles are present in the air, but any conclusion is made when is no aerosol in the enclosure. (author). 158 refs., 81 figs., 42 tabs

  10. Radon in Africa: South African Lessons Learnt

    International Nuclear Information System (INIS)

    Simanga, A.T.

    2010-01-01

    Radon remained a chemical curiosity for decades, promoted at some stage as a health giving gas. Mining related history: (based on ICRP 65) dating back to 15 Century when high mortality from lung cancer was observed among miners in Schneeberg. After the Curies had extracted Radium from Jachymov ores (1898), radon was identified. When measurements were done in Schneeberger and Jachymov mines high concentrations of radon were found. Initially a link was assumed between lung cancer and high radon concentration based on the measurements. (The assumption was not generally accepted).In 1953 William F. Bale indicated that the causative agents of lung cancer was the radon progeny and not radon gas. A possible lung cancer risk to members of the public was discovered very recently (first published results were based on the indoor measurements done in Sweden in a study initiated by Rolf Sievert) Much attention has been given to radon as a radiological health hazard: Recently human exposure to radon progeny in buildings has emerged as an important issue. Lung cancer is the principal concern associated with Rn exposure. The principal concern is associated with radon progeny. These species are chemically reactive, and may be deposited on respiratory tract tissues when inhaled. Subsequent alpha particle decay may damage cells near the deposition site, contributing to increased risk of lung cancer Radon: In Occupational Exposure Protection against Rn Exposure is a Techno-Legal Legal Aspects: There has to be a national legislative framework for the protection of workers against radon The legal framework should entail, inter alia: - Set up of regulator, development of regulations and standards to enable compliance assurance and other protection issues, training of technical people. 10 Legislative Framework in South Africa National Nuclear Regulatory Act (1999) Enables the regulator (NNR) to exercise oversight for Rn protection Occupational Exposure is mainly in Mining and Mineral

  11. Cone-beam local reconstruction based on a Radon inversion transformation

    International Nuclear Information System (INIS)

    Wang Xian-Chao; Yan Bin; Li Lei; Hu Guo-En

    2012-01-01

    The local reconstruction from truncated projection data is one area of interest in image reconstruction for computed tomography (CT), which creates the possibility for dose reduction. In this paper, a filtered-backprojection (FBP) algorithm based on the Radon inversion transform is presented to deal with the three-dimensional (3D) local reconstruction in the circular geometry. The algorithm achieves the data filtering in two steps. The first step is the derivative of projections, which acts locally on the data and can thus be carried out accurately even in the presence of data truncation. The second step is the nonlocal Hilbert filtering. The numerical simulations and the real data reconstructions have been conducted to validate the new reconstruction algorithm. Compared with the approximate truncation resistant algorithm for computed tomography (ATRACT), not only it has a comparable ability to restrain truncation artifacts, but also its reconstruction efficiency is improved. It is about twice as fast as that of the ATRACT. Therefore, this work provides a simple and efficient approach for the approximate reconstruction from truncated projections in the circular cone-beam CT

  12. Radon in homes of the Portland, Oregon Area: Radon data from local radon testing companies collected by CRM (Continuous Radon Measurement) machines

    Science.gov (United States)

    Whitney, H.; Lindsey, K.; Linde, T.; Burns, S. F.

    2013-12-01

    Students from the Department of Geology at Portland State University paired up with the Oregon Health Authority to better understand radon gas values in homes of the Portland metropolitan area. This study focuses on radon values collected by continuous radon measurement (CRM) machines, taken by local radon testing companies. The local companies participating in this study include Alpha Environmental Services, Inc., Cascade Radon, Environmental Works, The House Detectives, LLC, and Soil Solutions Environmental Services, Inc. In total, 2491 radon readings spanning across 77 zip codes were collected from local companies in the Portland metropolitan area. The maximum value, average value, percentage of homes greater than 4 pCi/L and total rank sum was calculated and used to determine the overall radon potential for each zip code (Burns et al., 1998). A list and four maps were produced showing the results from each category. Out of the total records, 24 zip codes resulted in high radon potential and the average reading for the entire Portland Metropolitan area was 3.7 pCi/L. High potential zip codes are thought to be a result of sand and gravel (Missoula Flood deposits) and faults present in the subsurface. The CRM data was compared with both long-term and short-term data provided by the Oregon Health Authority to validate radon potentials in each zip code. If a home is located in a zip code with high or moderate radon potential across two types of data sets, it is recommended that those homes be tested for radon gas.

  13. Radon in the indoor of habitable and workable zones in the Estado de Mexico; Radon en el interior de zonas habitacionales y laborables del Estado de Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Pena, P.; Segovia, N.; Gaso, M.I.; Ponciano, G. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The levels of the radon concentration and of suspended particles in the air of the indoor house-room and of laboratories, like part of a study related with the impact of the components of the tobacco smoke in the health of the active and passive smokers. The measures of the radon concentration were carried out with Honeywell A9000A systems and the fluctuations in the concentration and particle size they were determined with a Personal Measurer for the Data Acquisition of Particles in Real Time. The average value of the radon concentration inside the house-room was of 40 Bq m{sup -3}, observing frequently radon peaks superior to 148 Bq m{sup -3}. In the offices and laboratories, especially in those with little ventilation, the radon gas concentration showed superior values to the internationally established limits. The average value in 24 hours, of the particles (PM{sub 10}) inside the houses of smokers it was of 0. 751 {+-} 0.420 mg m{sup -3}, being reached concentrations so high as 1. 6 mg m{sup -3}, which is an order of superior magnitude to the maximum permissible limit of PM{sub 10} (0.150 mg m{sup -3}), settled down by the Mexican Legislation. (Author)

  14. Fractal characters and hurst exponent of radon exhalation rate from uranium Tailings

    International Nuclear Information System (INIS)

    Hu Hanqiao; Tan Kaixuan; Li Chunguang; Lv Junwen; Liu Dong

    2010-01-01

    The uranium tailings radon exhalation is an important environmental problem. The change of the radon exhalation rate of uranium tailings with the time through laboratory experiments is measured, and the results show that the radon exhalation rate of the tailings change obviously with time in non-periodic oscillations. Applying fractal analysis to the radon exhalation rate time-series data by R/S method, the Hurst exponent of the entire time series data is 0.83, the fractal dimension is 1.17. Mobile Hurst exponent is between 0.5 and 0.8 in most cases. The Hurst exponent of the experiments in the later part are below 0.5. The exhalation rate of uranium tailings radon does not meet the long-term trend of random walk theory, the radon exhalation rate has long-term memory, but the short-term memory is not distinct. The radon exhalation from uranium tailings is a deterministic chaotic dynamics. (authors)

  15. Measurements on, and modelling of diffusive and advective radon transport in soil

    DEFF Research Database (Denmark)

    Graff, E.R. van der; Witteman, G.A.A.; Spoel, W.H. van der

    1994-01-01

    Results are presented of measurements on radon transport in soil under controlled conditions with a laboratory facility consisting of a stainless steel vessel (height and diameter 2 m) filled with a uniform column of sand. At several depths under the sand surface, probes are radially inserted...... into the vessel to measure the radon concentration in the soil gas. To study advective radon transport a perforated circular box is placed in the sand close to the bottom of the vessel. By pressurising this box, an air flow through the sand column is induced. Radon concentration profiles were measured without...... an air flow as a function of time, and for several values of the air flow, equilibrium radon concentration profiles were measured....

  16. Radon measurements along active faults in the Langadas Basin, northern Greece

    Directory of Open Access Journals (Sweden)

    C. Papastefanou

    2001-01-01

    Full Text Available A network of three radon stations has been established in the Langadas Basin, northern Greece for radon monitoring by various techniques in earthquake prediction studies. Specially made devices with plastic tubes including Alpha Tracketch Detectors (ATD were installed for registering alpha particles from radon and radon decay products exhaled from the ground, every 2 weeks, by using LR-115, type II, non-strippable Kodak films, starting from December 1996. Simultaneous measurements started using Lucas cells alpha spectrometer for instantaneous radon measurements in soil gas, before and after setting ATDs at the radon stations. Continuous monitoring of radon gas exhaling from the ground started from the middle of August 1999 by using silicon diode detectors, which simultaneously register meteorological parameters, such as rainfall, temperature and barometric pressure. The obtained data were studied together with the data of seismic events, such as the magnitude, ML, of earthquakes that occurred at the Langadas Basin during the period of measurements, as registered by the Laboratory of Geophysics, Aristotle University of Thessaloniki, in order to find out any association between them.

  17. Studies of radon mitigation in well water by aeration

    International Nuclear Information System (INIS)

    Mafra, Karina Cristina; Paschuk, Sergei A.; Denyak, Valeriy; Reque, Marilson; Correa, Janine Nicolosi; Barbosa, Laercio

    2011-01-01

    The 222 Rn concentration in natural water in different countries usually is about few Bq/L and is the subject of the National legislation as well as International norms and recommendations. The United States Environmental Protection Agency (USEPA) established a limit of 11.1 Bq/L for the radon level in drinking water and this limit is considered as guideline in Canada and many countries of the European Union. This work presents the results of study of radon ( 222 Rn) concentration reduction in well water using the aeration process developed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR). The water samples were collected from a well at Pinheirinho region of Curitiba in 2011. Experimental setup was based on the Radon Monitor (AlphaGUARD). The 222 Rn concentration was analyzed using the software DataEXPERT by Genitron Instruments, taking into account the volume of water sample, its temperature, atmospheric pressure and the total volume of the air in the vessels. Initial concentration of radon in water samples was 28,67 Bq/L which is bigger than maximum concentration recommended by USEPA. The mitigation was performed by means of diffusion aeration of water samples of 15L during the time interval of 24 hours following a period of 4 days. The efficiency of aeration mitigation was controlled by comparing the activity of radon in aerated water with reference water samples that were not aerated. Obtained results show very satisfactory decrease of 222 Rn activity in water samples even after few hours of intense aeration. (author)

  18. Radon concentration in spring and groundwater of Shillong agglomeration

    International Nuclear Information System (INIS)

    Walia, D.; Wahlang, P.; Lyngdoh, A.C.; Saxena, A.; Sharma, Y.; Maibam, D.

    2010-01-01

    Water samples in the month of February 2010 to April 2010 are collected from 06 springs (sample code S1-S6) and 18 wells (sample code W1-W18) of the Shillong agglomeration in radon-tight 1L bottles, considering the geological structures, nearness to the steep slopes and accessibility of the water sources. The measurement of radon in water samples is carried out using ionization chamber Alphaguard along with an accessory (fabricated in the laboratory). Initially, background radon of the empty set-up is measured for 30 minutes before every water-sample measurement. The water samples are placed in a closed gas cycle in degassing vessel and then radon is expelled using the pump and magnetic stirrer. The security vessel is connected with the degassing vessel to minimize the inflow of water vapour to the Alphaguard. The measuring cycle is repeated 3 times in order to obtain a better precision. The arithmetic mean of the radon concentrations are used for calculating the annual effective dose for ingestion of water from each bore well and spring. The pH, electrical conductivity and temperature are measured so as to correlate the meteorological parameters with the radon emanation

  19. Calibration of radon-222 detectors using closed circuit radium-226 sources

    International Nuclear Information System (INIS)

    Perna, Allan Felipe Nunes; Paschuk, Sergei Anatolyevich; Correa, Janine Nicolosi; Del Claro, Flavia

    2012-01-01

    This paper presents the results of the calibration of the Radon-222 detectors used by the Laboratories specializing in measuring natural radiation from this gas. The research was conducted in collaboration between UTFPR, CDTN/CNEN, UFRN and IRD/CNEN. During the calibration the detectors were exposed in isolated chambers with radioactive calibrated sources. The calibration procedure was supported with four instant radon monitors AlphaGUARD (SAPHYMO Co.) responsible for radon activity measurements in the experimental chamber. The calibration procedure resulted an equation that relates the number of tracks found in solid-state detector CR-39 (Track-Etch detector) with the concentration of radon in the atmosphere. Obtained results are compatible with previously performed calibration at the National Institute of Radiological Sciences (NIRS, Japan) using high activity levels of radon in air. Present results of calibration give the possibility to expand the calibration curve of CR-39 for medium and low activity levels of radon. (author)

  20. Radon programme in the Czech Republic

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.

    2003-01-01

    The framework of the Radon programme in the Czech republic includes both precautionary measures and interventions. The programme informally started in early eighties has been now incorporated in national legislation (Atomic Act, Radiation Protection Decree, etc.). Aim of precautionary measures is to avert construction of building above natural radiation guidance levels (200 Bq/m 3 for indoor radon concentration and 0.5 Sv/h for gamma dose rate) by protection of new buildings against soil radon ingress, by regulation of natural radioactivity in building materials and supplied water. Aim of interventions is to identify buildings affected by enhanced natural radioactivity and help owners to put into effect reasonable remedial measures. Two sets of intervention levels for indoor natural exposure were established: guidance intervention levels 400 Bq/m 3 (indoor radon), 1.0 Sv/h (indoor gamma dose rate) and limit values 4000 Bq/m 3 and 10 Sv/h. The radon programme is based both on governmental and private activities. The governmental activities include representative and targeted indoor radon survey, subsidy for radon mitigation, mitigation test measurements and public information on radon issue. The private activities include radon measurement (radon index of building site, indoor measurements, radon diagnosis) and remedial measures. More than 100 commercial companies were authorised by Radiation Protection Authority (SUJB) to provide these measurements

  1. IN-SITU MEASURING METHOD OF RADON AND THORON DIFFUSION COEFFICIENT IN SOIL

    Directory of Open Access Journals (Sweden)

    V.S. Yakovleva

    2014-06-01

    Full Text Available A simple and valid in-situ measurement method of effective diffusion coefficient of radon and thoron in soil and other porous materials was designed. The analysis of numerical investigation of radon and thoron transport in upper layers of soil revealed that thoron flux density from the earth surface does not depend on soil gas advective velocity and varies only with diffusion coefficient changes. This result showed the advantages of thoron using versus radon using in the suggested method. The comparison of the new method with existing ones previously developed. The method could be helpful for solving of problems of radon mass-transport in porous media and gaseous exchange between soil and atmosphere.

  2. Radon analyser

    International Nuclear Information System (INIS)

    1981-01-01

    The process claimed includes the steps of transferring radon gas produced by a sample to a charcoal trap, cooled to a temperature whereby the radon is absorbed by the charcoal, heating the charcoal trap to a sufficient temperature to release the radon, and transferring the radon to a counting device where the gas particles are counted

  3. Use of natural basement ventilation to control radon in single family dwellings

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.

    1992-01-01

    Natural basement ventilation has always been recommended as a means of reducing radon levels in houses. However, its efficacy has never been documented. In these experiments, natural ventilation has for the first time been studied systematically in two research houses during both the summer cooling season and the winter heating season. Ventilation rates, environmental and house operating parameters, as well as radon levels, have been monitored. It can be definitely concluded from radon entry rate calculations that natural ventilation can reduce radon levels in two ways. The first is by simple dilution. The second is by reducing basement depressurization and thus the amount of radon-contaminated soil gas drawn into the structure. Therefore, basement ventilation can be an effective mitigation strategy under some circumstances. It might be especially useful in houses with low radon concentrations (of the order of 370 Bq m -1 ) or those with low levels and which cannot be mitigated cost-effectively with conventional technology. (Author)

  4. Survey of radon in dwellings in area strongly affected by mining

    International Nuclear Information System (INIS)

    Wysocka, M.; Chalupnik, S.; Mielnikow, A.; Skowronek, J.

    2002-01-01

    Due to the Decree of the President of Polish Atomic Energy Agency [21], the permissible level of radon concentration in new houses is 200 Bq/m 3 , while in existing houses -400 Bq/m 3 . This Decree is valid since January 1, 1998. Till now, radon investigations in Poland were done on a small scale. Therefore Central Mining Institute started at first screening campaign and later long term measurements of radon concentrations were done in area of Upper Silesia. Usually measurements of radon concentration in dwellings are performed at two stages. On the first stage, a screening is made by means of short term methods of radon measurement, like activated charcoal canisters or grab sampling to find places with elevated radon risk. On the second stage a long term measurements have been done in dwellings chosen during screening campaign.The method of the radon measurement by means of charcoal canisters was developed in our Laboratory in early 90's. We designed our own detectors with the activated charcoal, after the exposure radon from the charcoal is washed out with toluene-based liquid scintillator and measured in the liquid scintillation counter. The reliability of the results was proved in many intercomparison runs. For long term radon measurements the method of track etched detectors was applied. As a detector the LR-115 strippable foil was chosen and as a reader the spark counter was applied. As predicted, the highest values in dwellings were found at the ground floor level in several towns in northern part of Upper Silesia. All these sites are situated in area without an overburden of impermeable Miocene clays. Moreover, these towns are located within a specific geological structure, known as Bytom Syncline. In the underlying strata, the dominant rocks are Triassic, strongly weathered formations, in form of carbonates. We supposed, that the influence of geology would be intensified by coal mining. The presence of abandoned workings, excavations and cavities on

  5. Analysis of pre-service physics teacher skills designing simple physics experiments based technology

    Science.gov (United States)

    Susilawati; Huda, C.; Kurniawan, W.; Masturi; Khoiri, N.

    2018-03-01

    Pre-service physics teacher skill in designing simple experiment set is very important in adding understanding of student concept and practicing scientific skill in laboratory. This study describes the skills of physics students in designing simple experiments based technologicall. The experimental design stages include simple tool design and sensor modification. The research method used is descriptive method with the number of research samples 25 students and 5 variations of simple physics experimental design. Based on the results of interviews and observations obtained the results of pre-service physics teacher skill analysis in designing simple experimental physics charged technology is good. Based on observation result, pre-service physics teacher skill in designing simple experiment is good while modification and sensor application are still not good. This suggests that pre-service physics teacher still need a lot of practice and do experiments in designing physics experiments using sensor modifications. Based on the interview result, it is found that students have high enough motivation to perform laboratory activities actively and students have high curiosity to be skilled at making simple practicum tool for physics experiment.

  6. Comparison of radon diffusion coefficients measured by transient-diffusion and steady-state laboratory methods

    International Nuclear Information System (INIS)

    Kalwarf, D.R.; Nielson, K.K.; Rich, D.C.; Rogers, V.C.

    1982-11-01

    A method was developed and used to determine radon diffusion coefficients in compacted soils by transient-diffusion measurements. A relative standard deviation of 12% was observed in repeated measurements with a dry soil by the transient-diffusion method, and a 40% uncertainty was determined for moistures exceeding 50% of saturation. Excellent agreement was also obtained between values of the diffusion coefficient for radon in air, as measured by the transient-diffusion method, and those in the published literature. Good agreement was also obtained with diffusion coefficients measured by a steady-state method on the same soils. The agreement was best at low moistures, averaging less than ten percent difference, but differences of up to a factor of two were observed at high moistures. The comparison of the transient-diffusion and steady-state methods at low moistures provides an excellent verification of the theoretical validity and technical accuracy of these approaches, which are based on completely independent experimental conditions, measurement methods and mathematical interpretations

  7. NW Oregon radon potential based on soil radionuclides

    International Nuclear Information System (INIS)

    Ashbaugh, S.G.; Burns, S.F.

    1993-01-01

    Analysis of soil by gamma spectroscopy for Bi-214 (Ra-226) suggests low to moderate radon potentials for northwest Oregon in areas with low to moderate soil permeabilities. Very low radon potential zones (0.2 to 0.7 pCi/g) comprise 58% of the study area. These zones are frequently associated with soils developed from undifferentiated basalts and andesites of the Cascade Range, and basalts and undifferentiated mafic intrusives of the Coast Range. Low radon potential zones (0.7 to 1.2 pCi/g) comprise 28% of the study area. These zones are generally associated with Missoula Flood sediments, pre-Holocene loess in the Portland area, and Eocene/Oligocene marine sediments low in mica and/or tuff along the foothills of the Willamette Valley. Moderate radon potential zones (1.2 to 3.0 pCi/g) comprise 14% of the study area. These zones are often associated with the lateritic soils derived from Columbia River Basalts and Eocene/Oligocene marine sediments high in mica and/or tuff along the western edges of the Willamette Valley. A closer examination of soils in the Portland and Salem areas shows that: (1) Bi-214/K-40 ratios increase from 0.07 to 0.35 with respect to solid development, indicating K-40 to be preferentially leached over Ra-226; (2) clay development within B-horizons does not reflect a significant increase in Ra-226 mobility; and (3) elevated indoor radon within the Portland and Salem areas can be attributed to high soil permeabilities rather than soil chemistry

  8. Radon in coal power plant areas

    International Nuclear Information System (INIS)

    Mauna, Traian; Mauna, Andriesica

    2006-01-01

    corresponding lower exposure risk. The present work is a tentative initiative of warning, based on appropriate argumentation, the agents implied in coal-burning based electric energy and heat production in Romania to initiate actions aiming at diminishing radon risk and accordingly the lung cancer occurrence

  9. Radon diagnostics and tracer gas measurements

    International Nuclear Information System (INIS)

    Jilek, K.; Brabec, M.

    2004-01-01

    An outline is presented of the tracer gas technique, which is used for continuous measurements of air ventilation rate (generally time-varying) and for simultaneous estimation of air ventilation rate and radon entry rate, and some of its limitations are discussed. The performance of this technique in the calculation of the air ventilation rate is demonstrated on real data from routine measurements. The potential for air ventilation rate estimation based on radon measurements only is discussed. A practical application is described of the tracer gas technique to a simultaneous estimation of the air ventilation rate and radon entry rate in a real house where the effectiveness of radon remedy was tested. The following main advantages of the CO tracer gas techniques are stressed: (i) The averaging method continuous determination of the ventilation rate with good accuracy (≤ 20 %). (ii) The newly presented and verified method based on simultaneous measurements of radon concentration and CO gas concentration enables separate continuous measurements of the radon entry rate and ventilation rate. The results of comparative measurements performed with the aim to estimate the inaccuracy in determination of radon entry rate showed acceptable and good agreement up to approximately 10 %. The results of comparative measurements performed with the aim to estimate the mutual commensuration of the method to the determination of the ventilation rate confirmed the expected unreliability the two parametric non-linear regression method, which is the most frequently used method in radon diagnostic in the Czech Republic

  10. Meeting new challenges in radon measurements service with solid state alpha track analysis

    International Nuclear Information System (INIS)

    Calamosca, M.; Penzo, S.; Mustapha, A.O.

    2005-01-01

    Full text: The national and international legislation on the control of exposures to radiation now covers exposures to the naturally occurring radioactive materials (NORM), with particular emphasis on radon in workplaces. Consequently, many more working environments have now been brought to the realm of radiation monitoring. This is mirrored by a corresponding increase in the demands for radon monitoring service. The new challenges occasioned by the increase in demands are illustrated in this paper. The paper also describes the new integrated radon measurement system at the ENEA ION-IRP radon-in-air testing laboratory, designed to meet the new challenges. In this presentation emphasis is laid only on the special features, hardware and software, of the measurement system that directly result in enhancement of the overall throughput and the quality of the radon service. In addition the use of a new technique based on a numerical filtering of the main physical parameters of the alpha track analysis used to determine the radon exposure with a CR-39 detector is presented, with particular emphasis to the quality improvements of the measurement. The readout procedure adopted by the Enea radon Service is based on track analysis by light microscopy. Since the dimensions of the tracks are significantly affected by the light intensity, the illumination of the field of view (FOV) has to be as homogeneous as possible, in order to avoid sensitivity dependence on track position in the FOV. The lighting variation could be severe, especially at the borders or when a rectangular FOV is used. The coefficient of variation of the FOV light uniformity has to be periodically checked to maintain the variation below an acceptable limit, whereas if the results exceed this value a remedial action is mandatory. The numerical correction procedure here presented results effective. (author)

  11. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres. Progress report, July 1, 1992--March 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1992-07-01

    This report describes studies on the chemical and physical behavior of the {sup 218}Po atom immediately following its formation by the alpha decay of radon. Because small changes in size for activity in the sub-10 nm size range result in large changes in the delivered dose per unit exposure, this behavior must be understood if the exposure to radon progeny and its dose to the cells in the respiratory tract are to be fully assessed. The specific tasks of the controlled laboratory studies are to determine the formation rates of {center_dot}OH radicals formed by the radiolysis of air following radon decay, to examine the formation of particles by the radiolytic oxidation of substances like SO{sub 2} ethylene, and H{sub 2}S to lower vapor pressure compounds and determine the role of gas phase additives such as H{sub 2}O and NH{sub 3} in determining the particle size, to measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and to measure the neutralization rate of {sup 218}Po{sub x}{sup +} in O{sub 2} at low radon concentrations. Tasks of the exposure studies in occupied indoor spaces are to initiate measurements of the activity size distributions in actual homes with occupants present so that the variability of the indoor activity size distributions can be assessed with respect to indoor aerosol sources and general lifestyle variations of the occupants, to initiate a prospective study of the utility of measurement of deposited {sup 210}Pb embedded in glass surfaces as a measure of the long-term, integrated exposure of the population to radon, and to develop the methodology to determine the hygroscopicity of the indoor aerosol so that the changes in deposition efficiency of the radioactive indoor aerosol with hygroscopic growth in the respiratory tract can be assessed.

  12. Study of the atmospheric chemistry of radon progeny in laboratory and real indoor atmospheres. Progress report, May 1, 1993--January 31, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Hopke, P.K.

    1993-01-01

    Progress is reported on the chemical and physical behavior of the {sup 218}Po atom immediately following its formation by the alpha decay of radon. Two areas of radon progeny behavior are being pursued; laboratory studies under controlled conditions to better understand the fundamental physical and chemical processes that affect the progeny`s atmospheric behavior and studies in actual indoor environments to develop a better assessment of the exposure of the occupants of that space to the size and concentration of the indoor radioactive aerosol. The specific tasks addressed were to determine the formation rates of {center_dot}OH radicals formed by the radiolysis of air following radon decay, to examine the formation of particles by the radiolytic oxidation of substances like SO{sub 2}, ethylene, and H{sub 2}S to lower vapor pressure compounds and determine the role of gas phase additives such as H{sub 2}O and NH{sub 3} in determining the particle size, to measure the rate of ion-induced nucleation using a thermal diffusion cloud chamber, and to measure the neutralization rate of {sup 218}PoO{sub x}{sup +} in O{sub 2} at low radon concentrations. Initial measurements were conducted of the activity size distributions in actual homes with occupants present so that the variability of the indoor activity size distributions can be assessed with respect to indoor aerosol sources and general lifestyle variations of the occupants. A prospective study of the utility of measurement of deposited {sup 210}Pb embedded in glass surfaces as a measure of the long-term, integrated exposure of the population to radon are described. Methodology was developed to determine the hygroscopicity of the indoor aerosol so that the changes in deposition efficiency of the radioactive indoor aerosol with hygroscopic growth in the respiratory tract can be assessed.

  13. Investigations of radon and radon daughters in surficial aquifers of florida

    International Nuclear Information System (INIS)

    1991-05-01

    The principal purpose of the investigation was to test the hypothesis that radon soil flux, considered the principal source of indoor radon contamination, has an underlying relationship to the radon content of associated shallow groundwaters. The working hypothesis was that radon build-up in both soil and shallow groundwater is basically a consequence of the same factor, radon emanation from soil grains and the solid surfaces of the aquifers. Groundwater may be advantageous as an indicator of radon potential. Another object of the project was to investigate temporal and spatial trends of radon daughter products in shallow aquifers. After analyzing all of the radon soil, flux, and groundwater measurements made over the two-year study period, it is clear that while there is no direct relationship between either radon soil concentration or flux and groundwater radon. Measurements in wells where polonium is present at very high concentrations have shown that 210Po is largely unsupported by its radioactive predecessor, and that polonium is considerably more variable, in both space and time than other parameters measured in the same wells, including radon

  14. Surface-water radon-222 distribution along the west-central Florida shelf

    Science.gov (United States)

    Smith, C.G.; Robbins, L.L.

    2012-01-01

    In February 2009 and August 2009, the spatial distribution of radon-222 in surface water was mapped along the west-central Florida shelf as collaboration between the Response of Florida Shelf Ecosystems to Climate Change project and a U.S. Geological Survey Mendenhall Research Fellowship project. This report summarizes the surface distribution of radon-222 from two cruises and evaluates potential physical controls on radon-222 fluxes. Radon-222 is an inert gas produced overwhelmingly in sediment and has a short half-life of 3.8 days; activities in surface water ranged between 30 and 170 becquerels per cubic meter. Overall, radon-222 activities were enriched in nearshore surface waters relative to offshore waters. Dilution in offshore waters is expected to be the cause of the low offshore activities. While thermal stratification of the water column during the August survey may explain higher radon-222 activities relative to the February survey, radon-222 activity and integrated surface-water inventories decreased exponentially from the shoreline during both cruises. By estimating radon-222 evasion by wind from nearby buoy data and accounting for internal production from dissolved radium-226, its radiogenic long-lived parent, a simple one-dimensional model was implemented to determine the role that offshore mixing, benthic influx, and decay have on the distribution of excess radon-222 inventories along the west Florida shelf. For multiple statistically based boundary condition scenarios (first quartile, median, third quartile, and maximum radon-222 inshore of 5 kilometers), the cross-shelf mixing rates and average nearshore submarine groundwater discharge (SGD) rates varied from 100.38 to 10-3.4 square kilometers per day and 0.00 to 1.70 centimeters per day, respectively. This dataset and modeling provide the first attempt to assess cross-shelf mixing and SGD on such a large spatial scale. Such estimates help scale up SGD rates that are often made at 1- to 10-meter

  15. Etched track radiometers in radon measurements: a review

    CERN Document Server

    Nikolaev, V A

    1999-01-01

    Passive radon radiometers, based on alpha particle etched track detectors, are very attractive for the assessment of radon exposure. The present review considers various devices used for measurement of the volume activity of radon isotopes and their daughters and determination of equilibrium coefficients. Such devices can be classified into 8 groups: (i) open or 'bare' detectors, (ii) open chambers, (iii) sup 2 sup 2 sup 2 Rn chambers with an inlet filter, (iv) advanced sup 2 sup 2 sup 2 Rn radiometers, (v) multipurpose radiometers, (vi) radiometers based on a combination of etched track detectors and an electrostatic field, (vii) radiometers based on etched track detectors and activated charcoal and (viii) devices for the measurement of radon isotopes and/or radon daughters by means of track parameter measurements. Some of them such as the open detector and the chamber with an inlet filter have a variety of modifications and are applied widely both in geophysical research and radon dosimetric surveys. At the...

  16. Radon dosimetry: a review of radon and radon daughter exposure conditions in dwellings and other structures

    International Nuclear Information System (INIS)

    Ryan, M.T.; Goldsmith, W.A.; Poston, J.W.; Haywood, F.F.; Witherspoon, J.P.

    1983-07-01

    Within the past few years several situations have been brought to light which indicate an increased radiation exposure of certain segments of the general population caused by human activities. The most widely publicized activities are those associated with the mining and milling of uranium in the western United States, the phosphate industry in Florida, and those potential problems represented by former Manhattan Engineer District sites. One of the primary problems involves exposure to radon and radon daughters which are released from large waste piles or, in some cases, evolve from backfill and construction materials used in homes, schools, and other buildings. This report presents a review of the available data on radon and radon daughter concentrations in dwellings and other structures. The primary objectives were to compile and tabulate pertinent radon exposure data and to prepare a statistical summary of the data which will be useful in the prediction of normal levels of radon and radon daughter concentrations in these structures. In addition, other parameters associated with radon exposure conditions are presented and discussed

  17. Radon-daughter exposures in energy-efficient buildings

    International Nuclear Information System (INIS)

    Nero, A.V.; Berk, J.V.; Boegel, M.L.; Hollowell, C.D.; Ingersoll, J.G.; Nazaroff, W.W.

    1981-10-01

    A radon concentration of 1 pCi/1 (37 Bq/m 3 ) appears to lie in the range that is typical for air inside US residential buildings. Moreover, some US residences have concentrations higher than 1 pCi/1, sometimes by an order of magnitude, implying significant individual risk to occupants. For typical radon daughter equilibrium ratios, this concentration corresponds to a radon daughter exposure rate of 0.2 working level months (WLM) per year. This exposure rate may account for a significant lung cancer incidence if data on lung cancers per unit exposure in miners are applicable to such low exposures. Reductions in air exchange rates may rise the typical exposure rate and even increase it to unacceptable levels in some cases. Measures that reduce energy use by reducing natural infiltration or mechanical ventilation in new or retrofit buildings are therefore undergoing severe scrutiny. Lawrence Berkeley Laboratory has performed measurements in buildings specifically designed to use energy efficiently or utilize solar heating. In many of these buildings radon concentrations appear to arise primarily from soil underlying the buildings. Measures to control higher levels, e.g., by mechanical ventilation with heat recuperation, appear to be economical. However, to evaluate energy-saving programs adequately requires a much more comprehensive characterization of radon sources (for example, by geographical area) and a much fuller understanding of the dynamics of radon and its daughters indoors than now exist

  18. Application of underwater radon measurements in geology

    Energy Technology Data Exchange (ETDEWEB)

    Varhegyi, A.; Baranyi, I.; Gerzson, I. (Mecsek Ore Mining Enterprise, Pecs (Hungary)); Somogyi, G.; Hakl, J.; Hunyadi, I. (Magyar Tudomanyos Akademia, Debrecen (Hungary). Atommag Kutato Intezete)

    1988-01-01

    Based on the observed phenomenon of geogas migration in microbubble form from deeper regions, the authors have developed a new model for the vertical transport of radon released from deeper sources. The physical properties of the rock relating to the upflow of microbubbles below the groundwater level are considered and the radon transport parameter of rocks is introduced. The vertical distribution of radon concentration in the case of a multi-layered geological model is given and the penetration depth of underwater radon measurements is examined. Aspects of underwater radon detection by the nuclear track detector technique are analyzed. The radon transport model gives a new theoretical basis for several applications of radon measurements in geology. The advantages of underwater radon detection have already been proved in uranium exploration. Further geological applications are proposed in earthquake prediction, in volcanology, in the survey of active faults and thermal waters. (author).

  19. Radon reduction in crawl-space houses

    International Nuclear Information System (INIS)

    Osborne, M.C.; Moore, D.G.; Southerlan, R.E.; Brennan, T.; Pyle, B.E.

    1989-01-01

    This paper gives results of an EPA study of radon-mitigation alternatives for crawl space houses in several houses in Nashville, TN. Application of one of these alternative mitigation options, suction under a polyethylene membrane, has been successful in significantly reducing radon levels in both the crawl space and the house. The large radon concentrations measured under unvented plastic ground covers and the moisture barriers found in many crawl spaces can act as radon-rich reservoirs capable of contaminating a crawl space and house during periods of depressurization. With the exhaust components of the mitigation system in place, radon levels below the plastic decreased by more than 95% under both passive and active suction conditions. Based on the study, the design of a cost-effective subplastic suction passive radon mitigation system for crawl spaces seems promising

  20. Procedure for the characterization of radon potential in existing dwellings and to assess the annual average indoor radon concentration

    International Nuclear Information System (INIS)

    Collignan, Bernard; Powaga, Emilie

    2014-01-01

    Risk assessment due to radon exposure indoors is based on annual average indoor radon activity concentration. To assess the radon exposure in a building, measurement is generally performed during at least two months during heating period in order to be representative of the annual average value. This is because radon presence indoors could be very variable during time. This measurement protocol is fairly reliable but may be a limiting in the radon risk management, particularly during a real estate transaction due to the duration of the measurement and the limitation of the measurement period. A previous field study defined a rapid methodology to characterize radon entry in dwellings. The objective of this study was at first, to test this methodology in various dwellings to assess its relevance with a daily test. At second, a ventilation model was used to assess numerically the air renewal of a building, the indoor air quality all along the year and the annual average indoor radon activity concentration, based on local meteorological conditions, some building characteristics and in-situ characterization of indoor pollutant emission laws. Experimental results obtained on thirteen individual dwellings showed that it is generally possible to obtain a representative characterization of radon entry into homes. It was also possible to refine the methodology defined in the previous study. In addition, numerical assessments of annual average indoor radon activity concentration showed generally a good agreement with measured values. These results are encouraging to allow a procedure with a short measurement time to be used to characterize long-term radon potential in dwellings. - Highlights: • Test of a daily procedure to characterize radon potential in dwellings. • Numerical assessment of the annual radon concentration. • Procedure applied on thirteen dwellings, characterization generally satisfactory. • Procedure useful to manage radon risk in dwellings, for real

  1. The 2008 intercomparison exercise for radon gas measurement instruments at PSI; Die Vergleichsmessung 2008 fuer Radongasmessgeraete am PSI

    Energy Technology Data Exchange (ETDEWEB)

    Butterweck, G.; Schuler, Ch.; Mayer, S.

    2010-09-15

    Sixteen radon measurement services participated in the 2008 Radon Intercomparison Exercise performed at the Reference Laboratory for Radon Gas Activity Concentration Measurements at the Paul Scherrer Institute (PSI) during August 28{sup th} to September 7{sup th}, 2008 on behalf of the Swiss Federal Office of Public Health (FOPH). Twelve of these laboratories were approved by the FOPH and their participation in the intercomparison exercise was a requirement to warrant quality of measurement. Radon gas dosemeters (etched-track, electronic and electret ionisation chambers) and instruments (ionization chambers) were exposed in the PSI Radon Chamber in a reference atmosphere with an average radon gas concentration of 627 Bq m{sup -3} leading to a radon gas exposure of 155 kBq h m{sup -3}. One measuring instrument participating for testing purposes stored values for part of the exposure interval (30.8. - 7.9.2008). The exposure during this partial interval was 117 kBq h m{sup -3} at an average radon gas concentration of 624 Bq m{sup -3}. The exposure of 155 kBq h m{sup -3} was the lowest used at the PSI intercomparisons down to the present day. Especially the LLT electret ionisation chambers used by some of the laboratories reached the lower end of their measurement range with this exposure. Unexpected deviations of instruments of the same model seem to show a dependence on the serial number and thus production date. (authors)

  2. Point-of-entry removal of radon from drinking water

    International Nuclear Information System (INIS)

    Lowry, J.D.; Brutsaert, W.F.; Mc Enerney, T.; Molk, C.

    1987-01-01

    Two processes were investigated in the laboratory to determine their efficiency for removing radon from household water supplies. Granular activated carbon (GAC) adsorption was found to be extremely effective as a result of an adsorption-decay steady state that is established quickly and continues for years. The GAC bed, however, adsorbs radon progeny as the radon decays, and it becomes a source of gamma radiation. This problem is believed to be manageable for the vast majority of potential applications. Diffused bubble aeration was found to be as effective as GAC, with removals of greater than 99 percent being practical. Although more costly than GAC, aeration does not have the problem of gamma activity buildup

  3. Studies on the migration rule and mechanism of radon and its daughters

    International Nuclear Information System (INIS)

    Jia Wenyi; Fang Fang; Zhou Rongsheng; Ma Yingjie; Qiu Yuande; Hou Xinsheng; Wu Yunping; Zu Xiulan; Wang Xiaoqin

    2000-01-01

    By using very precise, highly sensitive, static accumulated, easily repeated CD-1 α-cup, the migration rule and mechanism of radon and its daughters was studied. Significant results were obtained: (1) Under laboratory conditions, the vertical component of migration of radon and its daughters was much greater than the horizontal component, the former was over 90% and the latter was less than 10%. (2) Despite the very big specific gravity of radon and its daughters, the descending component of migration was less than 45%, while the ascending component was more than 45%. (3) After α-particles (emitted from radon and its daughters) being slowed down. 4 He combined with the radon and its daughters to form clusters. When the density of the cluster was less than that of the air, the self-ascending would occur

  4. Background concentrations of radon and radon daughters in Canadian homes

    International Nuclear Information System (INIS)

    McGregor, R.G.; Vasudev, P.; Letourneau, E.G.; McCullough, R.S.; Prantl, F.A.; Taniguchi, H.

    1980-01-01

    Measurements of radon and radon daughters were carried out in 14 Canadian cities on a total of 9999 homes selected in a statistically random manner. The geometric means of the different cities varied from 0.14 to 0.88 pCi/l. for radon and 0.0009 to 0.0036 Working Levels for radon daughters. The radon originates from natural radioactivity in the soil surrounding the homes. (author)

  5. Design of automatic control system of temperature in radon chamber controlled by air-condition based on 485 BUS

    International Nuclear Information System (INIS)

    Man Zaigang; Wang Renbo; Zhang Xiongjie; Zhu Zhifu; Tang Bin

    2009-01-01

    Radon chamber can be widely used in various radon measurement instruments for calibration, testing and radon environment experiment. According to requisition, radon chamber temperature should be controllable from +10 degree C to +30 degree C, and the temperature control accuracy of the system reaches ±1 degree C. The design of automatic temperature controlled by air-condition based on 485 BUS is introduced. The software and hardware techniques of how the ATMEL89S52 micro controller controls air-condition and communicates with computer are elaborated on. (authors)

  6. Soil-gas radon as seismotectonic indicator in Garhwal Himalaya

    International Nuclear Information System (INIS)

    Ramola, R.C.; Prasad, Yogesh; Prasad, Ganesh; Kumar, Sushil; Choubey, V.M.

    2008-01-01

    Research on earthquake-related radon monitoring has received enormous attention recently. Anomalous behaviour of radon in soil and groundwater can be used as a reliable precursor for an impending earthquake. While earthquake prediction may not yet be possible, earthquake prediction research has greatly increased our understanding of earthquake source mechanisms, the structural complexities of fault zones, and the earthquake recurrence interval, expected at a given location. This paper presents some results of continuous monitoring of radon in soil-gas in Garhwal Himalaya, India. Daily soil-gas radon monitoring with seismic activity and meteorological parameters were performed in the same laboratory system, located at H.N.B. Garhwal University Campus, Tehri Garhwal, India. Radon anomalies along with meteorological parameters were found to be statistically significant for the seismic events within the magnitudes M2.0-M6.0 and epicentral distances of 16-250 km from the monitoring station. The frequent positive and negative anomalies with constant environmental perturbation indicate the opening and closing of micro cracks within the volume of dilatancy by strain energy. The spike-like and sharp peak anomalies were recorded before, during and after earthquakes occurred in the area. The variations in radon concentrations in soil-gas are found to be correlated with seismic activities in the Garhwal Himalaya. The correlation between radon level and meteorological parameters is also discussed

  7. Asian/Australian region intercalibration and intercomparison programme for radon: statistical analysis and propagation of uncertainity protocols for scintillation cells of the reference laboratory

    International Nuclear Information System (INIS)

    Gan, T.H.; Solomon, S.B.; Peggie, J.R.

    1990-01-01

    A series of intercomparison for radon was orgarnized by the Australian Radiation Laboratory (ARL) for twenty-eight laboratories from nine countries in the Asian/Australasian region. Methodology, results of intercalibration and statistical analysis for the four groups of NEW scintillation cells are described. The variability in the calibration factor of 3.4% for one standard deviation for the NEW set of cells, compared with 5.7% for the OECD cells indicates that the NEW cells measurements give greater consistency to the results. 5 refs., 2 tabs, 1 fig

  8. Design of a recirculating radon progeny aerosol generation and animal exposure system

    International Nuclear Information System (INIS)

    Newton, G.J.; Cuddihy, R.G.; Yeh, H.C.; Barr, E.B.; Boecker, B.B.

    1988-01-01

    Inhalation studies are being conducted at ITRI using laboratory animals exposed to radon-222 progeny attached to vector aerosols that are typical of indoor environments. The purpose of these studies is to identify the cells at risk from inhaled radon progeny and their locations within the respiratory tract. These studies require exposures up to 1000 working level months (WLM) within a few hours. Thus, large amounts of radium-226 are needed to produce the gaseous radon-222. A once-through-exposure-system was considered to be impractical because of statutory discharge limitations and the large amounts of radium that would be required. Therefore, a recirculating exposure system was designed and constructed that removes the aerosol after passing through the exposure chambers and recirculates purified air and radon. The purified radon is mixed with freshly evolving radon from a radon generator and passed Into a reaction-aging chamber where attachment of radon progeny to the vector aerosol occurs. The design includes: (1) 50-200 mg radium-226 in a radon generator, (2) 40 L/min total flow rate, (3) CO 2 removal, (4) reconstitution of oxygen tension and water vapor content to atmospheric levels, and (5) a trap for radon gas. A radon progeny exposure concentration in the range of 4,000 to 50,000 WL is being produced. (author)

  9. Radon in public buildings; Radon in oeffentlichen Gebaeuden

    Energy Technology Data Exchange (ETDEWEB)

    Schulz, H.; Flesch, K. [IAF - Radiooekologie GmbH, Dresden (Germany); Hermann, E. [B.P.S. Engineering GmbH, Zwickau (Germany); Loebner, W. [Wismut GmbH, Chemnitz (Germany); Leissring, B. [Bergtechnisches Ingenieurbuero GEOPRAX, Chemnitz (Germany)

    2009-07-01

    From the Free State of Saxony, a study was commissioned to survey how reliable measurements to characterize the radon situation in public buildings at a reasonable financial and human effort can be carried out to reduce radiation exposure in public buildings. The study approach was for 6 objects. To characterize the radon situation the time evolution measurement of radon concentrations of more than 1 to 2 weeks turned out to be sufficient. A novel data analysis enables the identification of a ''typical daily alteration of the radon concentration'' depending on the ventilation conditions and the daily use of the offices or class rooms. The identification of typical diurnal radon variations for the working time and weekends or holidays is of fundamental importance for assessing the exposure situation in public buildings. It was shown that the radon concentration during working time are in general much lower than in the times when the buildings (offices) are unused. It turned out that the long-term radon measurements with nuclear track detectors within distinct time regimes (day / night, working hours / leisure time) by utilizing switch modules are very efficient to estimate the actual exposure. (orig.)

  10. Asphalt emulsion radon barrier systems for uranium mill tailings: an overview of the technology

    International Nuclear Information System (INIS)

    Baker, E.G.; Hartley, J.N.; Freeman, H.D.; Gates, T.E.; Nelson, D.A.; Dunning, R.L.

    1984-03-01

    Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) office, has developed an asphalt emulsion cover system to reduce the release of radon from uranium mill tailings. The system has been field tested at Grand Junction, Colorado. Results from laboratory and field tests indicate that this system is effective in reducing radon release to near-background levels ( -2 s -1 ) and has the properties required for long-term effectiveness and stability. Engineering specifications have been developed, and analysis indicates that asphalt emulsion covers are cost-competitive with other cover systems. This report summarizes the technology for asphalt emulsion radon barrier systems. 59 references, 45 figures, 36 tables

  11. ERRICCA radon model intercomparison exercise

    International Nuclear Information System (INIS)

    Andersen, C.E.; Albarracin, D.; Csige, I.; Graaf, E.R. van der; Jiranek, M.; Rehs, B.; Svoboda, Z.; Toro, L.

    1999-04-01

    Numerical models based on finite-difference or finite-element methods are used by various research groups in studies of radon-222 transport through soil and building materials. Applications range from design of radon remediation systems to more fundamental studies of radon transport. To ascertain that results obtained with these models are of good quality, it is necessary that such models are tested. This document reports on a benchmark test organized by the EU project ERRICCA: European Research into Radon in Construction Concerted Action. The test comprises the following cases: 1) Steady-state diffusive radon profiles in dry and wet soils, 2) steady-state entry of soil gas and radon into a house, 3) time-dependent radon exhalation from a building-material sample. These cases cover features such as: soil heterogeneity, anisotropy, 3D-effects, time dependency, combined advective and diffusive transport of radon, flux calculations, and partitioning of radon between air and water in soil pores. Seven groups participated in the intercomparison. All groups submitted results without knowing the results of others. For these results, relatively large group-to-group discrepancies were observed. Because of this, all groups scrutinized their computations (once more) and engaged in follow-up discussions with others. During this debugging process, problems were indeed identified (and eliminated). The accordingly revised results were in better agreement than those reported initially. Some discrepancies, however, still remain. All in all, it seems that the exercise has served its purpose and stimulated improvements relating to the quality of numerical modelling of radon transport. To maintain a high quality of modelling, it is recommended that additional exercises are carried out. (au)

  12. Intercomparison of passive radon-detectors under field conditions in epidemiological studies.

    Science.gov (United States)

    Kreienbrock, L; Poffijn, A; Tirmarche, M; Feider, M; Kies, A; Darby, S C

    1999-05-01

    The Ardennes and Eifel region is a geologically distinct area covering parts of Germany, Belgium, France, and Luxembourg where enhanced concentrations of radon occur in some houses and other buildings. An international case-control study is being conducted to examine the role of radon in the etiology of lung cancer in this area. The radon detectors used are issued by different laboratories involving a variety of detector types and processes. A series of intercomparisons in houses was therefore conducted under similar conditions of exposure in the field. In most situations the different detectors gave similar results. Nevertheless, in some situations open and closed detectors yielded different results. Therefore, estimates of radon exposure have to be adjusted if results are to be pooled.

  13. Comparison of retrospective and contemporary indoor radon measurements in a high-radon area of Serbia

    International Nuclear Information System (INIS)

    Zunic, Z.S.; Yarmoshenko, I.V.; Kelleher, K.; Paridaens, J.; Mc Laughlin, J.P.; Celikovic, I.; Ujic, P.; Onischenko, A.D.; Jovanovic, S.; Demajo, A.; Birovljev, A.; Bochicchio, F.

    2007-01-01

    In Niska Banja, Serbia, which is a high-radon area, a comparison was made between two retrospective radon measuring methods and contemporary radon measurements. The two retrospective methods derive the radon concentrations that occurred in dwellings over longer periods in the past, based on the amount of trapped 210 Po on the surface of glass objects (surface traps, ST) or in the bulk of porous materials (volume traps, VT). Both surface implanted 210 Po in glass objects and contemporary radon in air were measured in 46 rooms, distributed in 32 houses of this radon spa-town, using a dual alpha track detector configuration (CR-39 and LR115) and CR-39 track etched detectors, respectively. In addition to the use of surface trap measurements, in 18 rooms (distributed in 15 houses) VT samples of suitable material were also collected, allowing to compare ST and VT retrospective radon concentration estimates. For each room, contemporary annual radon concentrations (CONT) were measured or estimated using seasonal correction factors. The distribution of the radon concentration in all data sets was found to be close to lognormal (Chi-square test > 0.05). Geometric means (GM) are similar, ranging from 1040 to 1380 Bq m -3 , whereas geometric standard deviations (GSD) for both the retrospective methods are greater than for the CONT method, showing reasonable agreement between VT, ST and CONT measurements. A regression analysis, with respect to the lognormal distribution of each data set, shows that for VT-ST the correlation coefficient r is 0.85, for VT-CONT r is 0.82 and for ST-CONT r is 0.73. Comparison of retrospective and contemporary radon concentrations with regard to supposed long-term indoor radon changes further supports the principal agreement between the retrospective and conventional methods

  14. Radon soil-gas concentration and exhalation from mine tailings dams in South Africa

    Energy Technology Data Exchange (ETDEWEB)

    Ongori, J.; Lindsay, R. [University of the Western Cape, Department of Physics, Private Bag X17, Bellville 7535 (South Africa); Newman, R. [Stellenbosch University, Department of Physics, Private Bag X1 Matieland 7602 (South Africa); Maleka, P. [iThemba LABS, Department of Nuclear Physics, P. O. Box 722, Somerset West 7129 (South Africa)

    2014-07-01

    In Africa as well as in the world, South Africa plays an important role in the mining industry which dates back almost 120 years. Mining activities in South Africa mainly take place in Gauteng Province. Every year million of tons of rocks are taken from underground, milled and processed to extract gold. The uranium bearing tailings are disposed in dumpsites. These tailings dumps contain considerable amounts of radium ({sup 226}Ra) and have therefore been identified as large sources of radon ({sup 222}Rn). Radon is a noble gas formed by the decay of radium which in turn is derived from the radioactive decay of uranium ({sup 238}U). Radon release from these tailings dumps pose health concerns for the surrounding communities. Radon soil gas concentrations and exhalations from a non-operational mine dump (Kloof) which belongs to Carletonville Gold Field, Witwatersrand, South Africa have been investigated. The continuous radon monitor, the Durridge RAD7 was used to measure {sup 222}Rn soil gas concentration in the tailings dump at five different spots. The radon soil gas concentration levels were measured at depths starting from 30 cm below ground/air interface up to 110 cm at intervals of 20 cm. The concentrations recorded ranged from 26±1 to 472±23 kBq.m{sup -3}. Furthermore, thirty four soil samples were taken from the spots where radon soil gas measurements were measured for laboratory-based measurement using the low background Hyper Pure Germanium (HPGe) gamma-ray detector available at the Environmental Radioactivity Laboratory (ERL), iThemba LABS, Western Cape Province. The soil samples were collected in the depth range 0-30 cm. After analysis the weighted average activity concentrations in the soils samples were 308±7 Bq.kg{sup -1}, 255±5 Bq.kg{sup -1} and 18±1 Bq.kg{sup -1} for {sup 238}U, {sup 40}K and {sup 232}Th, respectively. A number of factors such as the radium activity concentration and its distribution in soil grains, soil grain size, soil porosity

  15. Radon in Austria

    International Nuclear Information System (INIS)

    Friedmann, H.

    2000-01-01

    Several projects in Austria deal with the problem of enhanced radon exposure to the public. The Austrian Radon Project is the largest project within this task, with the aim of investigating the radon concentrations in Austrian homes. Another project concerns mitigation methods. According to the EU directive EURATOM 96/29 it is also necessary to check working places for possibly enhanced radon concentrations. These projects are and will be funded by the government. The federal government of Upper Austria sponsored a project to test the indoor air quality in kindergartens including radon measurements. Within an EU research project, the radon concentrations in Austrian springs and groundwater were systematically listed and analyzed. Additional investigations will focus on methods to improve the radon potential maps from the Austrian Radon Project by including geological and other information. (author)

  16. Measurements of indoor radon and radon progeny in Mexico City

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Rodriguez, G.P.

    1996-01-01

    Indoor radon has been a public concern associated with increased lung cancer risks. Radon decay products interact with indoor aerosols to form progeny with different size distributions, which may influence the lung dosimetry when the progeny are inhaled. Air pollution in Mexico City is a serious problems with high particulate concentrations, but there are few reports of indoor radon measurement. The purposes of this study were to measure the aerosol concentration, radon concentration, and radon activity size distribution in the living area of three houses in Mexico City. The radon concentration was monitored by a RGM-3 radon gas monitor (Eberline, Inc., Santa Fe, NM). A graded diffusion battery was used to determine the progeny concentration and activity size distribution. The concentration and size distribution of the indoor aerosols were monitored by a quartz, crystal microbalance cascade impactor. Our measurements showed high concentrations of indoor aerosols (20-180 gg m -3 ). However, the radon concentrations-were low ( -1 ), but showed a clear diurnal pattern with peak concentrations from 2-10 AM. The activity size distributions of radon progeny were trimodal, with peaks of 0.6 nm, 4-5 nm, and 100 rim. Most activities were associated with large particle sizes. Our results indicated that indoor radon concentration was not high, due in part to a relatively high air exchange with outdoor air. The high aerosol concentration may also play an important part in the activity size distribution of radon progeny

  17. Tracing and dealing with dwellings with high radon and radon daughter concentrations

    International Nuclear Information System (INIS)

    Ehdwall, Hans

    1980-01-01

    In the late 1970s it was found that a number of buildings in Sweden, primarily those made from alum shale-based concretes, had elevated radon and radon daughter levels. A special commission investigated the problem and established provisional limiting values for radon daughter exposures, gamma radiation from the ground, and the concentrations of radioactive materials in building materials. With regard to gamma radiation from the ground the commission proposed that no building be built in an area where outside gamma radiation exceeds 100 μR/h. For building materials a gamma index (mγ) and a radium index (mRa) are suggested: mγ = Csub(K)/10000 + Csub(Ra)/1000 + Csub(Th)/700; mRa = Csub(Ra)/200 (Csub(K), Csub(Ra) and Csub(Th) are the concentrations of potassium, radium and thorium respectively). The proposed limiting values are such that the gamma index and the radium index be less than 1. It is also suggested that action should be taken to reduce radon levels in buildings with radon daughter concentrations of 0.27 WL within two years and 0.10 WL within 5 years

  18. Radon and radon daughters in South African underground mines

    International Nuclear Information System (INIS)

    Rolle, R.

    1980-01-01

    Radon and the radon daughters are the radionuclides which primarily determine the level of the radiation hazard in underground uranium mines and to a smaller extent in non-uranium mines. Radon is a gas, and its daughters adsorb on aerosol particles which are of respirable size. The hazard thus arises from the alpha decay of radon and its daughters in contact with lung tissue. Radon is itself part of the uranium decay chain. The major radionuclide, 238 U, decays successively through thirteen shorter-lived radionuclides to 206 Pb. Radon is the only gaseous decay product at room temperature; the other twelve are solids. The main hazard presented by the uranium decay chain is normally determined by the radon concentration because gaseous transport can bring alpha emitters close to sensitive tissue. There is no such transport route for the other alpha emitters, and the level of beta and gamma radiation caused by the uranium decay chain generally presents a far lower external radiation hazard. Radon itself is the heaviest of the noble gases, which are He, Ne, Ar, Kr, Xe and Rn. Its chemical reactions are of no concern in regard to its potential hazard in mines as it may be considered inert. It does, however, have a solubility ten times higher than oxygen in water, and this can play a significant part in assisting the movement of the gas from the rock into airways. Radon continuously emanates into mine workings from uranium ores and from the uranium present at low concentrations in practically any rock. It has been found that the control of the exposure level is most effectively achieved by sound ventilation practices. In South African mines the standard of ventilation is generally high and exposure to radon and radon daughters is at acceptably low levels

  19. Particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist Route "Liczyrzepa" Mine in Kowary Adit

    Science.gov (United States)

    Wołoszczuk, Katarzyna; Skubacz, Krystian

    2018-01-01

    Central Laboratory for Radiological Protection, in cooperation with Central Mining Institute performed measurements of radon concentration in air, potential alpha energy concentration (PAEC), particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist-Educational Route "Liczyrzepa" Mine in Kowary Adit. A research study was developed to investigate the appropriate dose conversion factors for short-lived radon progeny. The particle size distribution of radon progeny was determined using Radon Progeny Particle Size Spectrometer (RPPSS). The device allows to receive the distribution of PAEC in the particle size range from 0.6 nm to 2494 nm, based on their activity measured on 8 stages composed of impaction plates or diffusion screens. The measurements of the ambient airborne particle size distribution were performed in the range from a few nanometres to about 20 micrometres using Aerodynamic Particle Sizer (APS) spectrometer and the Scanning Mobility Particle Sizer Spectrometer (SMPS).

  20. Spectral-ratio radon background correction method in airborne γ-ray spectrometry based on compton scattering deduction

    International Nuclear Information System (INIS)

    Gu Yi; Xiong Shengqing; Zhou Jianxin; Fan Zhengguo; Ge Liangquan

    2014-01-01

    γ-ray released by the radon daughter has severe impact on airborne γ-ray spectrometry. The spectral-ratio method is one of the best mathematical methods for radon background deduction in airborne γ-ray spectrometry. In this paper, an advanced spectral-ratio method was proposed which deducts Compton scattering ray by the fast Fourier transform rather than tripping ratios, the relationship between survey height and correction coefficient of the advanced spectral-ratio radon background correction method was studied, the advanced spectral-ratio radon background correction mathematic model was established, and the ground saturation model calibrating technology for correction coefficient was proposed. As for the advanced spectral-ratio radon background correction method, its applicability and correction efficiency are improved, and the application cost is saved. Furthermore, it can prevent the physical meaning lost and avoid the possible errors caused by matrix computation and mathematical fitting based on spectrum shape which is applied in traditional correction coefficient. (authors)

  1. Experimental animal studies of radon and cigarette smoke

    International Nuclear Information System (INIS)

    Cross, F.T.; Dagle, G.E.; Gies, R.A.; Smith, L.G.; Buschbom, R.L.

    1992-01-01

    Cigarette-smoking is a dominant cause of lung cancer and confounds risk assessment of exposure to radon decay products. Evidence in humans on the interaction between cigarette-smoking and exposure to radon decay products, although limited, indicates a possible synergy. Experimental animal data, in addition to showing synergy, also show a decrease or no change in risk with added cigarette-smoke exposures. This article reviews previous animal data developed at Compagnie Generale des Matieres Nucleaires and Pacific Northwest Laboratory (PNL) on mixed exposures to radon and cigarette smoke, and highlights new initiation-promotion-initiation (IPI) studies at PNL that were designed within the framework of a two-mutation carcinogenesis model. Also presented are the PNL exposure system, experimental protocols, dosimetry, and biological data observed to date in IPI animals

  2. Radon and energy efficient homes

    International Nuclear Information System (INIS)

    Burkart, W.

    1981-09-01

    Radon and its daughters in indoor air are presently responsible for dose equivalents of about 31 mSv/year (3 rem/year) to parts of the respiratory tract. Linear extrapolation from the dose response values of uranium miners heavily exposed to radon and its decay products would suggest that almost all lung cancers in the non-smoking population are caused by environmental 222 Rn. Using epidemiological data on the types of lung cancer found in non-smokers of the general public as compared to the miners, a smaller effect of low level radon exposure is assumed, which would result in a lung cancer mortality rate due to radon of about 10 deaths per year and million or 25% of the non-smoker rate. Higher indoor radon concentrations in energy efficient homes mostly caused by reduced air exchange rates will lead to a several fold increase of the lung cancer incidence from radon. Based on the above assumption, about 100 additional lung cancer deaths/year-million will result both from an increase in radionuclide concentrations in indoor air and a concomitant rise in effectiveness of radiation to cause cancer with higher exposure levels. Possibilities to reduce indoor radon levels in existing buildings and costs involved are discussed. (Auth.)

  3. Radon dosimetry for workers: ICRP's approach

    International Nuclear Information System (INIS)

    Marsh, James W.; Laurier, Dominique; Tirmarche, Margot

    2017-01-01

    The International Commission on Radiological Protection (ICRP) has recently published two reports on radon exposure; Publication 115 on lung cancer risks from radon and radon progeny and Publication 126 on radiological protection against radon exposure. A specific graded approach for the control of radon in workplaces is recommended where a dose assessment is required in certain situations. In its forthcoming publication on Occupational Intakes of Radionuclides (OIR) document, Part 3, effective dose coefficients for radon and thoron will be provided. These will be calculated using ICRP reference biokinetic and dosimetric models. Sufficient information and dosimetric data will be given so that site-specific dose coefficients can be calculated based on measured aerosol parameter values. However, ICRP will recommend a single dose coefficient of 12 mSv per working level month (WLM) for inhaled radon progeny to be used in most circumstances. This chosen reference value was based on both dosimetry and epidemiological data. In this paper, the application and use of dose coefficients for workplaces are discussed including the reasons for the choice of the reference value. Preliminary results of dose calculations for indoor workplaces and mines are presented. The paper also briefly describes the general approach for the management of radon exposure in workplaces based both on ICRP recommendations and the European directive (2013/59/EURATOM). (authors)

  4. Development of an on-line radon monitoring apparatus and design of the on-line radon monitoring platform based on CAN bus

    International Nuclear Information System (INIS)

    Guo Huiping; Lu Ning; Shang Aiguo; Zhou Chunlin; Chen Yingfen; Yu Hongwei

    2004-12-01

    For actual demand, an idea of 'on-line monitoring' is put forward as a way of radon monitoring, instead of traditional so called 'off-line monitoring'. In this way, the apparatus has some automatic functions such as continuous monitoring, real-time alarm; thereby, there is no need for operators' intervention in each monitoring process. With technique of hardware and software design in automation's field, the authors have successfully developed the prototype and finished the scale of it in a standard radon-chamber. This apparatus is composed of detector part and secondary-instrument. The detector part is made up of a passive diffusion collecting chamber, high voltage static electricity, semiconductor detector, charge-sensitive preamplifier and forming circuit. The secondary-instrument is actually a micro-controller system, which consists of a single-chip micro-controller cored measure-controlling unit, display unit, printing unit and alarming unit. Taking this apparatus as a cell, a 'on-line Radon Monitoring Platform' based on CAN bus has been put forward, which can realize multi-points environmental radioactivity real-time monitoring radioactivity and data process. (authors)

  5. Report on the second international workshop on residential radon: Workshop proceedings

    International Nuclear Information System (INIS)

    1991-07-01

    As a follow-on to the first International Workshop on Residential Radon Epidemiology held in Alexandria VA, on July 24-26, 1989, a Second Workshop was convened, in Alexandria, VA, July 22-23 1991, also under the auspices of the US Department of Energy and the Commission of European Communities. The Workshop, co-chaired by Jonathan Samet and Jan Stolwijk, was attended by 20 active participants from seven countries representing epidemiologic studies recently completed, currently in progress, or in the last stages of preparation. The studies reported on are being conducted in the United States, Canada, Sweden, the United Kingdom, France, Belgium, Germany and the Peoples' Republic of China. The invited presentations that initiated the Workshop focused on a number of methodological problems that have surfaced in the last few years. Among these were: (1) the difficulties in predicting indoor radon concentrations, based on geologic information, (discussed by Alan Tanner, formerly of the US Geologic Survey); (2) the relationships between indoor radon concentrations and building characteristics (discussed by Richard Sextro, Lawrence Berkeley Laboratory, USA); (3) the approaches to analysis of case-control studies in radon epidemiology (discussed by Sarah Darby, Imperial Cancer Research Fund, UK); (4) statistical approaches to error in measurements and missing data (discussed by Donna Spiegelman, Tufts University, USA); (5) preliminary results of a data pooling effort dealing with several different studies of residential radon epidemiology and the lessons to be drawn from this effort (discussed by Jay Lubin, US National Cancer Institute)

  6. Development of a PIN diode based on-line measurement system for Radon (222Rn) and Thoron (220Rn) in environment

    International Nuclear Information System (INIS)

    Ashokkumar, P.; Chaudhury, Probal; Sumesh, C.G.; Sahoo, B.K.; Gaware, J.J.; Mayya, Y.S.

    2014-01-01

    Radon, thoron and their progenies are universally present in outdoor air, and can reach higher levels in indoor air due to poor ventilation. Several instruments have been developed for accurate measurement of radon and thoron in the environment. Semiconductor detector based system employing spectroscopic method has been proved to be the best among them. A PIN diode based electrostatic collection type online real-time instrument has been developed in Bhabha Atomic Research Centre for simultaneous measurement of radon and thoron in an environment while both 222 Rn and 220 Rn are present. This system can be used for determination of radon and thoron concentrations at residence or workplace. Furthermore, since the 222 Rn and 220 Rn are differentiated from each other through spectroscopy, this monitor can be used even in a mixed radon/thoron environment

  7. Radon programme in Czech Republic. Results, experience and future

    International Nuclear Information System (INIS)

    Hulka, J.; Thomas, J.; Fojtikova, I.; Vlcek, J.; Moucka, L.; Fronka, A.; Jilek, K.; Heribanova, A.; Slovak, J.; Barnet, I.; Burian, I.; Jiranek, M.; Cechak, T.

    2004-01-01

    The beginning of the radon programme in the Czech republic dates back to the early 1980s. Incorporated in national legislation (Atomic Act, Radiation Protection Decree), the programme includes now both preventive measures and interventions. Preventive measures are based on the control of major potential radon sources (soil gas, building material and supplied water) to prevent construction of new houses where the recommended indoor radon level of 200 Bq/m 3 would be exceeded. Radon risk (index) assessment of the individual building site bedrock in the case of new house siting and building protection as stipulated by the technical building code are obligatory. The estimation of the radon-related index of building sites is based on a standard method involving a set of radon soil and soil permeability measurements. In addition, producers of building materials are obligated to monitor natural radioactivity in their products. The activity index (including 40 K, 226 Ra and 232 Th) is used as a screening level for regulation of the potential indoor gamma dose rate, and the 226R a mass activity is used as a limiting value for radon exhalation. A similar regulatory system is in place for public water supplies based on obligatory radon, total alpha and total beta measurements. A survey of effectiveness of the preventive measures was carried out during the past years. It appeared, however, that the indoor radon level of 200 Bq/m 3 is exceeded in some 20 % of new houses. An unexpectedly low air exchange rate in modern energy-saving houses seems to be among the reasons. Remedial actions are aimed at promoting targeted indoor radon survey in existing buildings and helping owners to put reasonable remedial measures into effect. Governmental activities include representative and targeted indoor radon survey, subsidies for remediation measures and test measurements, and improving the level of public awareness of the radon issue. Indoor radon survey is targeted on radon-prone areas

  8. Determination of equilibrium factor between radon and its progeny using surface barrier detector for various shapes of passive radon dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Jamil, K. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Fazal-ur-Rehman [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Ali, S. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group; Khan, H.A. [PINSTECH, Islamabad (Pakistan). Environ. Radiat. Group

    1997-03-21

    In the field of radon dosimetry, it is customary to measure radon ({sup 222}Rn) concentration while potential health hazard is due to the radon short-lived progeny. When radon is in secular equilibrium, the measured activity of radon equals the activity of radon`s progeny. However, in practical cases an inequilibrium between radon and its progeny exists which is measured in terms of the equilibrium factor. To determine the equilibrium factor between radon and its progeny in a closed environment various shapes of passive dosimeters based upon solid state nuclear track detectors (SSNTDs) are employed. In order to observe the dependence of equilibrium factor upon shapes or effective volumes, experiments have been performed replacing the SSNTDs with a surface barrier detector in Karlsruhe diffusion chamber, pen-type and box-type dosimeters. Using the collected alpha spectra, the equilibrium factor has been determined for a radon-air mixture in a custom designed radon chamber simulating a closed environment of a room. The results show that the radon equilibrium factor is about 0.20 for different shapes of dosimeters studied in this research. It is concluded that the determination of equilibrium factor between radon and its progeny does not depend upon effective volume or shape of the passive dosimeters using alpha spectroscopic data acquired by surface barrier detector. (orig.).

  9. Indoor radon

    International Nuclear Information System (INIS)

    1997-12-01

    The radon, a natural radioactive gas, is present almost everywhere on the earth's surface. It can be accumulated at high concentration in confined spaces (buildings, mines, etc). In the last decades many studies conducted in several countries showed that inhaling important amounts of radon rises the risk of lung cancer. Although, the radon is a naturally appearing radioactive source, it may be the subject of a human 'enhancement' of concentration. The increasing radon concentration in professional housing constitutes an example of enhanced natural radioactivity which can induce health risks on workers and public. Besides, the radon is present in the dwelling houses (the domestic radon). On 13 May 1996, the European Union Council issued the new EURATOM Instruction that establishes the basic standards of health protection of population and workers against the ionizing radiation hazards (Instruction 96/29/EURATOM, JOCE L-159 of 29 June 1996). This instruction does not apply to domestic radon but it is taken into consideration by another EURATOM document: the recommendation of the Commission 90/143/EURATOM of 21 February 1990 (JOCE L-80 of 27 March 1990). The present paper aims at establishing in accordance to European Union provisions the guidelines for radon risk management in working places, as well as in dwelling houses, where the implied risk is taken into account. This document does not deal with cases of high radon concentration on sites where fabrication, handling or storage of radium sources take place. These situations must be treated by special studies

  10. Radon reduction and radon-resistant construction demonstrations in New York state. Final report

    International Nuclear Information System (INIS)

    1991-02-01

    A survey of radon levels in New York State homes indicates that approximately 4.4 percent of the homes have long-term living area radon concentrations above the U.S. EPA guideline of four pCi/l. The project addressed the effectiveness of techniques to reduce the radon level in existing homes and to prevent the occurrence of high radon concentrations in new homes. The goal of the project was to demonstrate the effectiveness of radon reduction techniques in homes containing indoor radon concentrations of more than the current EPA guidelines of four pCi/l. At the same time, radon-resistant construction techniques were demonstrated in homes under construction to provide guidelines for houses being built in areas with a danger of high radon levels. The project demonstrated new radon mitigation techniques in homes containing indoor radon concentrations exceeding four pCi/l; assessed the value of previously installed radon reduction procedures, and demonstrated new radon-resistant construction methods

  11. Mechanisms of radon injury

    International Nuclear Information System (INIS)

    Cross, F.T.

    1988-01-01

    In this new project, they conduct molecular, cellular and whole-animal research relevant to understanding the inhalation toxicology of radon and radon-daughter exposures. The work specifically addresses the exposure-rate effect in radon-daughter carcinogenesis; the induction-promotion relationships associated with exposure to radon and cigarette-smoke mixtures; the role of oncogenes in radon-induced cancers; the effects of radon on DNA as well as on DNA repair processes; and the involvement of growth factors and their receptors in radon-induced carcinogenesis. Preliminary experiments showed that oncogenes are activated in radon-induced lung tumors. They have therefore begun further exposures pertinent to the oncogene and growth-factor studies. An in vitro radon cellular-exposure system was designed, and cell exposures were initiated. Initiation-promotion-initiation studies with radon and cigarette-smoke mixtures have also begun; and they are compiling a radon health-effects bibliography

  12. Radiometers for radon concentration in air

    International Nuclear Information System (INIS)

    Bartak, J.; Machaj, B.; Pienkos, J.P.

    2002-01-01

    Constant grow of science and technology stimulates development of new improved measuring tools. New measuring demand arise also in radon concentration measurements. Varying rock stress and rock cracks influencing radon emanation encouraged research aimed at use of this phenomenon to predict crumps of mine formation among others based on variation of radon emanation. A measuring set was developed in the Institute of Nuclear Chemistry and Technology enabling long term monitoring of radon concentration in mine bore-hole. The set consists probe and probe controller. Detection threshold of the probe is 230 Bq/m 3 . The set can operate in the environment with methane explosion hazard. A radiometer employing Lucas cell as radiation detector for radon concentration in air was also developed its detection threshold is approx. 10 Bq/m 3 . Replaceable Lucas cell of the radiometer allows for measurement of high as well as low radon concentration in short time interval. (author)

  13. The radon transform. Theory and implementation

    International Nuclear Information System (INIS)

    Toft, P.

    1996-01-01

    The subject of this Ph.D. thesis is the mathematical Radon transform, which is well suited for curve detection in digital images, and for reconstruction of tomography images. The thesis is divided into two main parts. Part I describes the Radon- and the Hough-transform and especially their discrete approximations with respect to curve parameter detection in digital images. The sampling relationships of the Radon transform is reviewed from a digital signal processing point of view. The discrete Radon transform is investigated for detection of curves, and aspects regarding the performance of the Radon transform assuming various types of noise is covered. Furthermore, a new fast scheme for estimating curve parameters is presented. Part II of the thesis describes the inverse Radon transform in 2D and 3D with focus on reconstruction of tomography images. Some of the direct reconstruction schemes are analyzed, including their discrete implementation. Furthermore, several iterative reconstruction schemes based on linear algebra are reviewed and applied for reconstruction of Positron Emission Tomography (PET) images. A new and very fast implementation of 2D iterative reconstruction methods is devised. In a more practical oriented chapter, the noise in PET images is modelled from a very large number of measurements. Several packagers for Radon- and Hough-transform based curve detection and direct/iterative 2D and 3D reconstruction have been developed and provided for free. (au) 140 refs

  14. World Health Organization's International Radon Project 2005-2008

    International Nuclear Information System (INIS)

    Carr, Zhanat; Shannoun, Ferid; Zielinski, Jan M.

    2008-01-01

    worldwide, and has also produced the interactive web based map of national levels of residential radon around the world. The WHO Radon handbook includes chapters on exposure guidelines, measurement, mitigation, cost-effectiveness and radon risk communication, as well as a background chapter and recommendations for policies leading to radon risk reduction. Both WHO-IRP outputs provides sound, evidence-based guidance and tools for radon control measures including the cost-effectiveness analysis of available approaches. (author)

  15. Results of the 2001 NRPB intercomparison of passive radon detectors

    CERN Document Server

    Howarth, C B

    2002-01-01

    As in previous years, an intercomparison of passive radon detectors was held at NRPB in 2001. Forty-seven laboratories submitted 62 sets of passive detectors to this intercomparison. The exercise included three exposures to radon and its decay products at different equilibrium factors. An additional exposure at the CERN - EU high Energy Reference Facility (CERF) to a simulated cosmic ray spectrum was also offered to participants. After exposure, the detectors were returned to their originating laboratories for assessment. Participants reported the estimated exposure for each detector before they were notified of the exposures given to the detectors. The results obtained by participating laboratories were classified according to the spread of results from detectors exposed together and by the difference between the mean result of each group and the actual exposure given. Thirty-five percent of the laboratories achieved the highest classification for accuracy, while 9% were in the lowest category. The proportio...

  16. Calibration of SSNDT detectors for radon measurements

    International Nuclear Information System (INIS)

    Takahashi, Laura C.; Santos, Talita O.; Pinheiro, Rose Mary M.; Rocha, Zildete

    2017-01-01

    The methods and instrumentation used to measure the concentration of radon need to be calibrated to obtain accurate results. The Nuclear Track Detector is considered the main method of analysis of radon research. Thus, the Natural Radioactivity Laboratory of the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG, Brazil) uses the detector CR-39 (Landauer) to measure the concentration of radon in homes, workplaces, underground mines, soils and in environment. Epidemiological studies reveal the strong relationship between lung cancer and radon exposure. Therefore, it is important to monitor this gas and its progeny in order to assess the radiological risk. The alpha particles emitted by radon and its progeny leave traces on CR-39 due to Coulombian interactions with the atoms of the material. The liquid density of traces is converted to radon concentration by means of a calibration factor obtained in calibrated systems. This work aims to determine the LRN / CDTN calibration factor. To do so, the CR-39 detectors were placed inside the calibration chambers, along with two AlphaGUARD (Saphymo GmbH) detectors and Ra-266 sources with activities of 3,379 kBq or 0.483 kBq, referenced by NIST. From this, six levels of exposure were obtained, which were: 44 kBq.d.m 3 , 4 kBq.d.m 3 , 3 kBq.d.m 3 , 15 kBq.d.m 3 , 30 kBq.d.m 3 , 26 kBq.d.m 3 . The conversion factor between the liquid density of traces and the total exposure time obtained was K = 52.028 ± 0.752 [(trace density.cm -2 ) / (kBq.d.m -3 )]. After the determination of the conversion factor, it was used to measure the concentration of radon in underground mines, obtaining concentration results between 122 ± 24 and 7384 ± 517 kBq.m -3

  17. Asphalt emulsion radon barrier systems for uranium mill tailings: an overview of the technology

    Energy Technology Data Exchange (ETDEWEB)

    Baker, E.G.; Hartley, J.N.; Freeman, H.D.; Gates, T.E.; Nelson, D.A.; Dunning, R.L.

    1984-03-01

    Pacific Northwest Laboratory (PNL), under contract to the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action Project (UMTRAP) office, has developed an asphalt emulsion cover system to reduce the release of radon from uranium mill tailings. The system has been field tested at Grand Junction, Colorado. Results from laboratory and field tests indicate that this system is effective in reducing radon release to near-background levels (<2.5 pCi m/sup -2/s/sup -1/) and has the properties required for long-term effectiveness and stability. Engineering specifications have been developed, and analysis indicates that asphalt emulsion covers are cost-competitive with other cover systems. This report summarizes the technology for asphalt emulsion radon barrier systems. 59 references, 45 figures, 36 tables.

  18. Construction of radon/radon daughter calibraton chamber

    International Nuclear Information System (INIS)

    Fry, J.; Gan, T.H.; Leach, V.A.; Saddlier, J.; Solomon, S.B.; Tam, K.K.; Travis, E.; Wykes, P.

    1983-01-01

    The radon/radon daughter test chamber is a copper lined room 1.65x1.75x2.75m with an effective volume of 8000 litres. The air residence time is controlled by circulating the air in the chamber through absolute filters which remove 99.9% of particulates. Radon is drawn into the chamber from a 17 μCi 226 RaCl source using the pressure differential across the blowers (<3 psi)

  19. Application of single-chip microcomputer to portable radon and radon daughters monitor

    International Nuclear Information System (INIS)

    Meng Yecheng; Huang Zhanyun; She Chengye

    1992-01-01

    Application of single-chip microcomputer to portable radon and radon daughters monitor is introduced in this paper. With the single-chip microcomputer automation comes into effect in the process from sampling to measuring of radon and radon daughters. The concentrations of radon and radon daughters can be easily shown when the conversion coefficients are pre-settled before the measurement. Moreover, the principle and design are briefly discussed according to the characteristics of the monitor

  20. Compact detector for radon and radon daughter products

    International Nuclear Information System (INIS)

    Alter, H.W.; Oswald, R.A.

    1986-01-01

    This invention provides an improved compact track registration detector for radon gas. The detector comprises a housing having an open mouth, a bottom, and side walls; track registration means, supported inside the housing, which forms damage tracks along paths traversed by alpha particles; a microporous filter positioned across the mouth of the housing to prevent entry of radon daughters and particulate matter; and a cap that may be placed on the mouth of the housing to retain the filter. The housing has internal wall surfaces dimensioned to optimize the registration of alpha particles from radon and radon daughters present in the housing

  1. Radon: A health problem and a communication problem

    International Nuclear Information System (INIS)

    Johnson, R.H.

    1992-01-01

    The US Environmental Protection Agency (USEPA) is making great efforts to alert the American public to the potential health risks of radon in homes. The news media have widely publicized radon as a problem; state and local governments are responding to public alarms; and hundreds of radon open-quotes expertsclose quotes are now offering radon detection and mitigation services. Apparently, USEPA's communication program is working, and the public is becoming increasingly concerned with radon. But are they concerned with radon as a open-quotes healthclose quotes problem in the way USEPA intended? The answer is yes, partly. More and more, however, the concerns are about home resale values. Many homebuyers are now deciding whether to buy on the basis of a single radon screening measurement, comparing it with USEPA's action guide of 4 pCi L -1 . They often conclude that 3.9 is OK, but 4.1 is not. Here is where the communication problems begin. The public largely misunderstands the significance of USEPA's guidelines and the meaning of screening measurements. Seldom does anyone inquire about the quality of the measurements, or the results of USEPA performance testing? Who asks about the uncertainty of lifetime exposure assessments based on a 1-hour, 1-day, 3-day, or even 30-day measurement? Who asks about the uncertainty of USEPA's risk estimates? Fortunately, an increasing number of radiation protection professions are asking such questions. They find that USEPA's risk projections are based on many assumptions which warrant further evaluation, particularly with regard to the combined risks of radon and cigarette-smoking. This is the next communication problem. What are these radiation professions doing to understand the bases for radon health-risk projections? Who is willing to communicate a balanced perspective to the public? Who is willing to communicate the uncertainty and conservatism in radon measurements and risk estimates?

  2. Development of a portable radon progeny monitor

    International Nuclear Information System (INIS)

    Iimoto, Takeshi; Kosako, Toshiso; Sugiura, Nobuyuki

    2000-01-01

    Important nuclides in the radon family contributing to the effective dose are the members of the radon short-life progeny, 218 Po and 214 Po and direct measurement of these progenies is suitable for dosimetry. Survey of the radon progeny concentrations in a number of dwellings and offices is very difficult because we have no convenient instrument for the measurement. At present, radon dosimetry is carried out based on the concentration of the parent radon itself. Therefore, for accurate estimation of public or personal effective dose, it is necessary to develop a facile and portable radon progeny monitor. In this study, a portable radon progeny monitor (PRPM) was designed and developed to automatically estimate the individual progeny concentration in the natural environment. The properties of PRPM were investigated. The dimensions of the entire instrument were 65 x 145 x 170 mm and the total weight was 780 g. The portability of PRPM was much superior to the conventional instrument. The PRPM can operate automatically to estimate individual progeny concentration. All component materials of the monitor were selected based on the data of specified performance, cost performance and availability bon the market. The concentration of individual radon progeny was estimated by the build-up decay. It was concluded that PRPM is much suitable for outdoor study and personal dose estimation, as well as indoor measurement. In the field survey, especially in mines and caverns, PRPM is found as a valuable and convenient instrument. (M.N.)

  3. The design and realization of calibration apparatus for measuring the concentration of radon in three models

    Energy Technology Data Exchange (ETDEWEB)

    Huiping, Guo [The Second Artillery Engineering College, Xi' an (China)

    2007-06-15

    For satisfying calibration request of radon measure in the laboratory, the calibration apparatus for radon activity measure is designed and realized. The calibration apparatus can auto-control and auto-measure in three models. sequent mode, pulse mode and constant mode. The stability and reliability of the calibration apparatus was tested under the three models. The experimental result shows that the apparatus can provides an adjustable and steady radon activity concentration environment for the research of radon and its progeny and for the calibration of its measure. (authors)

  4. Collaborative Proposal: DUSEL R and D at the Kimballton Underground Facility (ICP-MS Confirmation, Material Assay, and Radon Reduction)

    International Nuclear Information System (INIS)

    Back, Henning O.

    2010-01-01

    Experiments measuring rare events, such as neutrinoless double beta (0νββ) decay, and those searching for, or measuring very weakly interacting particles, such as low energy solar neutrino experiments or direct dark matter searches, require ever lower backgrounds; particularly those from radioactive contamination of detector materials. The underground physics community strives to identify and develop materials with radioactive contamination at permissible levels, and to remove radioactive contaminants from materials, but each such material represents a separate dedicated research and development effort. This project attempted to help these research communities by expanding the capabilities in the United States, for indentifying low levels of radioactive contamination in detector materials through gamma ray spectroscopy. Additionally the project tried to make a cross comparison between well established gamma ray spectroscopy techniques for identifying radioactive contaminations and Inductively Coupled Plasma Mass Spectroscopy, which is a relatively new method for searching for uranium and thorium in materials. The project also studied the removal of radioactive radon gas for laboratory air, which showed that an inexpensive technologically simple radon scrubber can potentially be used for homes or businesses with high radon levels even after the employment of other mitigation techniques.

  5. Comparative study of radon exposure in Canadian homes and uranium mines - a discussion on the importance of national radon program

    International Nuclear Information System (INIS)

    Chen, Jing

    2017-01-01

    The history of lung cancer in uranium miners is well known for over hundreds of years when the disease was referred to as 'miner's disease' or 'mountain sickness'. Radon levels in uranium mines have decreased significantly over the past 30 years as a result of effective radiation protection measures at workplaces. For the most recent 10-year period, the average radon concentrations to underground and surface workers in Canadian uranium mines were 111 and 11 Bq m -3 , respectively. Based on the recent radon survey carried out in roughly 14 000 homes in 121 health regions across Canada and the more recent radon and thoron survey in 33 Canadian cities and 4000 homes, the average radon concentration in Canadian homes is 77 Bq m -3 . This study demonstrates that, nowadays, workers are exposed to radon in underground mines at a comparable radon level to what Canadians are exposed to at home. Since exposure to indoor radon is the main source of natural radiation exposure to the population, it is important for the National Radon Program to further increase radon awareness, and to encourage more Canadians to take appropriate actions to reduce radon exposure. (authors)

  6. Radon-Instrumentation; Radon-Instrumentacion

    Energy Technology Data Exchange (ETDEWEB)

    Moreno y Moreno, A. [Departamento de Apoyo en Ciencias Aplicadas, Benemerita Universidad Autonoma de Puebla, 4 Sur 104, Centro Historico 72000 Puebla (Mexico)

    2003-07-01

    The presentation of the active and passive methods for radon, their identification and measure, instrumentation and characteristics are the objectives of this work. Active detectors: Active Alpha Cam Continuous Air Monitor, Model 758 of Victoreen, Model CMR-510 Continuous Radon Monitor of the Signature Femto-Tech. Passive detectors: SSNTD track detectors in solids Measurement Using Charcoal Canisters, disk of activated coal deposited in a metallic box Electrets Methodology. (Author)

  7. Estimating the dynamics of groundwater input into the coastal zone via continuous radon-222 measurements

    International Nuclear Information System (INIS)

    Burnett, William C.; Dulaiova, Henrieta

    2003-01-01

    Submarine groundwater discharge (SGD) into the coastal zone has received increased attention in the last few years as it is now recognized that this process represents an important pathway for material transport. Assessing these material fluxes is difficult, as there is no simple means to gauge the water flux. To meet this challenge, we have explored the use of a continuous radon monitor to measure radon concentrations in coastal zone waters over time periods from hours to days. Changes in the radon inventories over time can be converted to fluxes after one makes allowances for tidal effects, losses to the atmosphere, and mixing with offshore waters. If one assumes that advective flow of radon-enriched groundwater (pore waters) represent the main input of 222 Rn in the coastal zone, the calculated radon fluxes may be converted to water fluxes by dividing by the estimated or measured 222 Rn pore water activity. We have also used short-lived radium isotopes ( 223 Ra and 224 Ra) to assess mixing between near-shore and offshore waters in the manner pioneered by . During an experiment in the coastal Gulf of Mexico, we showed that the mixing loss derived from the 223 Ra gradient agreed very favorably to the estimated range based on the calculated radon fluxes. This allowed an independent constraint on the mixing loss of radon--an important parameter in the mass balance approach. Groundwater discharge was also estimated independently by the radium isotopic approach and was within a factor of two of that determined by the continuous radon measurements and an automated seepage meter deployed at the same site

  8. Investigation of radon-222 in subsurface waters as an earthquake predictor

    International Nuclear Information System (INIS)

    Smith, A.R.; Bowman, H.R.; Mosier, D.F.; Asaro, F.; Wollenberg, H.A.; King, C.Y.

    1975-11-01

    Changes of radon-222 content of well waters in seismically active regions may provide earthquake precursor signals, according to reports of recent Chinese and Russian work. A high-precision γ-ray system for continuous monitoring of radon in wells and springs has been developed at the Lawrence Berkeley Laboratory, where monitoring began in April 1975, and has been extended to other sites including the San Andreas fault zone

  9. Determination of equilibrium factor between radon and its progeny using surface barrier detector for various shapes of passive radon dosimeters

    International Nuclear Information System (INIS)

    Jamil, K.; Fazal-ur-Rehman; Ali, S.; Khan, H.A.

    1997-01-01

    In the field of radon dosimetry, it is customary to measure radon ( 222 Rn) concentration while potential health hazard is due to the radon short-lived progeny. When radon is in secular equilibrium, the measured activity of radon equals the activity of radon's progeny. However, in practical cases an inequilibrium between radon and its progeny exists which is measured in terms of the equilibrium factor. To determine the equilibrium factor between radon and its progeny in a closed environment various shapes of passive dosimeters based upon solid state nuclear track detectors (SSNTDs) are employed. In order to observe the dependence of equilibrium factor upon shapes or effective volumes, experiments have been performed replacing the SSNTDs with a surface barrier detector in Karlsruhe diffusion chamber, pen-type and box-type dosimeters. Using the collected alpha spectra, the equilibrium factor has been determined for a radon-air mixture in a custom designed radon chamber simulating a closed environment of a room. The results show that the radon equilibrium factor is about 0.20 for different shapes of dosimeters studied in this research. It is concluded that the determination of equilibrium factor between radon and its progeny does not depend upon effective volume or shape of the passive dosimeters using alpha spectroscopic data acquired by surface barrier detector. (orig.)

  10. Study on absolute humidity influence of NRL-1 measuring apparatus for radon

    International Nuclear Information System (INIS)

    Shan Jian; Xiao Detao; Zhao Guizhi; Zhou Qingzhi; Liu Yan; Qiu Shoukang; Meng Yecheng; Xiong Xinming; Liu Xiaosong; Ma Wenrong

    2014-01-01

    The absolute humidity and temperature's effects on the NRL-1 measuring apparatus for radon were studied in this paper. By controlling the radon activity concentration of the radon laboratory in University of South China and improving the temperature and humidity adjust strategy, different correction factor values under different absolute humidities were obtained. Moreover, a correction curve between 1.90 and 14.91 g/m"3 was also attained. The results show that in the case of absolute humidity, when it is less than 2.4 g/m"3, collection efficiency of the NRL-1 measuring apparatus for radon tends to be constant, and the correction factor of the absolute humidity closes to 1. However, the correction factor increases nonlinearly along with the absolute humidity. (authors)

  11. What did we learn from the Austrian radon project?

    International Nuclear Information System (INIS)

    Friedmann, H.

    2004-01-01

    Approximately 40000 measurements of indoor radon concentrations were performed in randomly selected homes during the Austrian Radon Project. These measurements were carried out by using long-term measuring devices (SSNTD and Electret detectors) and short-term charcoal detectors with liquid scintillation counting as the method of analysis. In addition to the equilibrium factor, soil gas measurements and quasi-continuous indoor measurements, parallel-measurements with different detector systems in randomly selected homes were also performed. Very different results were occasionally obtained for one and the same room at the same time. This was so not only when comparing the long-term and short-term measuring devices; actually, different long-term detector systems also often showed significant discrepancies in results, although all detector systems had been carefully calibrated and tested in laboratories. The essential conclusion was that during a longer exposure in randomly selected homes, the detectors may be moved, opened, or handled in other unfavourable ways which introduce additional uncertainties in the measuring results. The aim of the Austrian Radon Project was to estimate the radon risk for geographic areas (municipalities). This task is different from the evaluation of the mean radon concentration in a single home. Generally, while long-term measurements (a year or even longer) are necessary to get reliable results for a particular house, this is not so where only the mean indoor radon concentrations for an area are of interest. Observed indoor radon concentrations give information about the actual radon exposures of the inhabitants but not about the radon risk from the ground. The house type, the way the house is constructed, the storey where people live, and some living patterns (ventilation rate etc.) modify the geological risk significantly, although it is the geological situation that has to be primarily taken into account when planning and constructing

  12. Excess bottom radon 222 distribution in deep ocean passages

    International Nuclear Information System (INIS)

    Sarmiento, J.L.; Broecker, W.S.; Biscaye, P.E.

    1978-01-01

    Radon 222 and STD profiles were obtained as part of the Geosecs program in the Vema Channel in the southwest Atlantic Ocean and in the Samoan, Clarion, and Wake Island passages in the Pacific Ocean. The standing crop of excess radon 222 is higher in the passages than at other nearby locations. The most likely explanation for this is that there is a high flux of radon 222 from the floor of the passages. Since much of the floor is covered with manganese nodules and encrustations, the high flux of radon 222 may be attributable to the high concentrations of radium 226 in the outer few millimeters of such deposits. Laboratory measurements of radon 222 emissivity from maganese encrustations obtained in Vema Channel support this hypothesis. The excess radon 222 in the Vema Channel and Wake Island Passage is found in substantial quantities at heights above bottom greatly exceeding the heights at which excess radon 222 is found in nonpassage areas. The horizontal diffusion of radon emanating from the walls of the passages is unlikely to be the cause of the observed concentrations because the ratio of wall surface area to water volume is very low. The profiles must therefore be a result of exceptionally high apparent vertical mixing in the passages. Further work is needed to determine the nature of this apparent vertical mixing. The excess radon 222 and STD data in all four passages have been fit with an empirical model in which it is assumed that the bouyancy flux is constant with distance above bottom. The fits are very good and yield apparent buoyancy fluxes that are between 1 and 3 orders of magnitude greater than those obtained at nearby stations outside the passages for three of the four passages

  13. Evolution of radon dose evaluation

    Directory of Open Access Journals (Sweden)

    Fujimoto Kenzo

    2004-01-01

    Full Text Available The historical change of radon dose evaluation is reviewed based on the United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR reports. Since 1955, radon has been recognized as one of the important sources of exposure of the general public. However, it was not really understood that radon is the largest dose contributor until 1977 when a new concept of effective dose equivalent was introduced by International Commission on Radiological Protection. In 1982, the dose concept was also adapted by UNSCEAR and evaluated per caput dose from natural radiation. Many researches have been carried out since then. However, lots of questions have remained open in radon problems, such as the radiation weighting factor of 20 for alpha rays and the large discrepancy of risk estimation among dosimetric and epidemiological approaches.

  14. Problems of the inclusion of workplaces with enhanced radon and radon daughter concentrations into occupational radiation protection control

    International Nuclear Information System (INIS)

    Przyborowski, S.

    1993-01-01

    New international recommendations (ICRP-60) on inclusion of workplaces with enhanced radon and radon daughter concentrations into occupational control are expected. Based on present regulations in Germany the problems of their implementation into radiation protection practice will be discussed. For underground workplaces and workplaces in radon spas and waterworks problems may be exist in particular points, whereas inclusion of workplaces in buildings seems to be problematicly in general. (orig./HP) [de

  15. A remote controlled system for continuous radon measurements to realize a monitoring network

    International Nuclear Information System (INIS)

    Roca, V.; Pugliese, M.; Venoso, G.; Roca, V.; Boiano, A.; D'Onofrio, A.; Pugliese, M.; Sabbarese, C.; Venoso, G.; D'Onofrio, A.; Sabbarese, C.

    2006-01-01

    R.A.M.O.N.A. (radon monitoring and acquisition) is a compact system for radon and climatic parameters monitoring. The instrument can perform alpha particles spectrometry with a resolution better than .5 %, so it is possible the discrimination of radon and thoron daughters. The development of battery operated electronics with integrated amplifier and micro controller makes the device applicable for in-lab and in-field measurements. Moreover, an ethernet interface allows to remotely drive the system and the download of acquired data. After a wide use of the prototype in laboratory, a lot of systems has been built and installed in some sites to carry out radon monitoring in soil. (authors)

  16. Intercomparison and intercalibration of active and passive radon detectors in North America

    International Nuclear Information System (INIS)

    George, A.C.

    1991-04-01

    The state of the art of the most commonly used instrumentation for radon measurements was evaluated at an intercomparison exercise held at the Environmental Measurements Laboratory, between April 24, and May 10, 1990. More than 50 sets of active and passive devices were submitted for evaluation by 30 laboratories from private firms, local, state and federal agencies and universities. There were basically five different types of detectors representing the majority of instruments used to assess the indoor airborne concentration of radon. After exposure, the devices were returned to the participating laboratories for analysis. The results reported to EML indicate that the overall performance was good with the majority of the participating laboratories reporting mean results within 10% of the EML reference values. In general, the majority of radon measuring devices gave slightly lower readings than the reference values. The individual measurements made with activated carbon collectors of both the open face and diffusion barrier type and the electret/ionization chambers showed the best precision and accuracy. The nuclear track detectors showed mixed results, exhibiting the largest measurement errors. This suggests that there are problems with sensitivity and with quality control procedures that must be addressed to improve their performance. 7 refs., 1 fig., 2 tabs

  17. Uncertainties of estimating average radon and radon decay product concentrations in occupied houses

    International Nuclear Information System (INIS)

    Ronca-Battista, M.; Magno, P.; Windham, S.

    1986-01-01

    Radon and radon decay product measurements made in up to 68 Butte, Montana homes over a period of 18 months were used to estimate the uncertainty in estimating long-term average radon and radon decay product concentrations from a short-term measurement. This analysis was performed in support of the development of radon and radon decay product measurement protocols by the Environmental Protection Agency (EPA). The results of six measurement methods were analyzed: continuous radon and working level monitors, radon progeny integrating sampling units, alpha-track detectors, and grab radon and radon decay product techniques. Uncertainties were found to decrease with increasing sampling time and to be smaller when measurements were conducted during the winter months. In general, radon measurements had a smaller uncertainty than radon decay product measurements. As a result of this analysis, the EPA measurements protocols specify that all measurements be made under closed-house (winter) conditions, and that sampling times of at least a 24 hour period be used when the measurement will be the basis for a decision about remedial action or long-term health risks. 13 references, 3 tables

  18. Interactive house investigation and radon diagnostics computer program

    International Nuclear Information System (INIS)

    Gillette, L.M.

    1990-01-01

    This paper reports on the interactive computer program called Dungeons and Radon which was developed as part of the Environmental Protection Agency's (EPA's) Radon Contractor Proficiency (RCP) Program's Radon Technology for Mitigators (RTM) course which is currently being offered in the Regional Radon Training Centers (RRTCs). The program was designed by Terry Brennan to be used in training radon mitigation contractors. The Macintosh based program consists of a series of animated, sound and voice enhanced house scenes. The participants choose where and what to investigate and where to perform diagnostic tests in order to gather enough information to design a successful mitigation system

  19. Radon programme: presence and future

    International Nuclear Information System (INIS)

    Hulka, J.

    2009-01-01

    In this presentation an overview of radon programme experiences is presented. The paper summarises national radon policy, national programmes, legislation, the role of preventive measures and interventions with respect to existing and future exposure and knowledge of radon risk, problems of remediation strategies, practical protection in dwellings, radon measurements strategies, progress in radon measurement of an individual house (radon diagnosis), radon mapping process and sense of delineation of radon prone areas, natural radioactivity of building materials and radioactivity in public water and their role in the radon programme, public awareness on radon issue and publicity campaign. Some research activities are proposed aiming at effective solutions of radon issues in future

  20. Radon levels and transport parameters in Atlantic Forest soils

    International Nuclear Information System (INIS)

    Farias, E.E.G. de; Silva Neto, P.C. da; Souza, E.M. de; De Franca, E.J.; Hazin, C.A.

    2016-01-01

    In natural forest soils, the radon transport processes can be significantly intensified due to the contribution of living organism activities to soil porosity. In this paper, the first results of the radon concentrations were obtained for soil gas from the Atlantic Forest, particularly in the Refugio Ecologico Charles Darwin, Brazil. The estimation of permeability and radon exhalation rate were carried out in this conservation unit. For forested soils, radon concentrations as high as 40 kBq m -3 were found. Based on the radon concentrations and on the permeability parameter, the results indicated considerable radon hazard for human occupation in the neighborhood. (author)

  1. Radon

    International Nuclear Information System (INIS)

    1990-01-01

    This leaflet in the At-a-Glance Series, describes what radon is, where it is found, why it presents a risk to health, the official advice, and the remedies that are available to reduce radon levels. (author)

  2. Development of a framework of quality assurance practices for a radon passive dosemeter service

    International Nuclear Information System (INIS)

    D'Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M

    2010-01-01

    Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.

  3. Development of a framework of quality assurance practices for a radon passive dosemeter service

    Energy Technology Data Exchange (ETDEWEB)

    D' Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M, E-mail: rosabianca.trevisi@ispesl.i [National Institute for Occupational Prevention and Safety (ISPESL), Via Fontana Candida 1, 00040 Monteporzio Catone (Rome) (Italy)

    2010-06-15

    Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.

  4. Development of a framework of quality assurance practices for a radon passive dosemeter service.

    Science.gov (United States)

    D'Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M

    2010-06-01

    Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.

  5. Radon anomalies: When are they possible to be detected?

    Science.gov (United States)

    Passarelli, Luigi; Woith, Heiko; Seyis, Cemil; Nikkhoo, Mehdi; Donner, Reik

    2017-04-01

    Records of the Radon noble gas in different environments like soil, air, groundwater, rock, caves, and tunnels, typically display cyclic variations including diurnal (S1), semidiurnal (S2) and seasonal components. But there are also cases where theses cycles are absent. Interestingly, radon emission can also be affected by transient processes, which inhibit or enhance the radon carrying process at the surface. This results in transient changes in the radon emission rate, which are superimposed on the low and high frequency cycles. The complexity in the spectral contents of the radon time-series makes any statistical analysis aiming at understanding the physical driving processes a challenging task. In the past decades there have been several attempts to relate changes in radon emission rate with physical triggering processes such as earthquake occurrence. One of the problems in this type of investigation is to objectively detect anomalies in the radon time-series. In the present work, we propose a simple and objective statistical method for detecting changes in the radon emission rate time-series. The method uses non-parametric statistical tests (e.g., Kolmogorov-Smirnov) to compare empirical distributions of radon emission rate by sequentially applying various time window to the time-series. The statistical test indicates whether two empirical distributions of data originate from the same distribution at a desired significance level. We test the algorithm on synthetic data in order to explore the sensitivity of the statistical test to the sample size. We successively apply the test to six radon emission rate recordings from stations located around the Marmara Sea obtained within the MARsite project (MARsite has received funding from the European Union's Seventh Programme for research, technological development and demonstration under grant agreement No 308417). We conclude that the test performs relatively well on identify transient changes in the radon emission

  6. Radon from coal ash in Colorado. Final report

    International Nuclear Information System (INIS)

    Morse, J.G.

    1981-01-01

    An attempt was made to develop a radiation profile of Colorado, based on available measured radon data. Data reported indicate that the release of radon to the atmosphere during uranium milling and mining is not a significant health hazard or air pollutant, when compared with radon in soils. 1 figure, 2 tables

  7. A technical evaluation of the EDA radon gas continuous monitoring system

    International Nuclear Information System (INIS)

    Bigu, J.

    1979-04-01

    Extensive laboratory and underground tests were conducted with a radon gas continuous monitoring system built by EDA Instruments Inc. The system consists of several remote radon gas sensors linked via signal cables to a central control unit that fully controls the operation of the radon monitors. The system enables four operations to be performed: sampling, background, flush and bypass. The sequence and duration of these functions is programmable. Up to 20 functions in any desired pattern each lasting from 1 min to 23 hr 59 min can be programmed. Several programs were used during the experiments in order to obtain radon and thoron gas levels. The performance of the EDA system was quite satisfactory. It is suggested that ruggedization as well as some other modifications be introdouced into the system to: a) better withstand the harsh underground environment; and b) improve its performance

  8. Radon emanation from backfilled mill tailings in underground uranium mine.

    Science.gov (United States)

    Sahu, Patitapaban; Mishra, Devi Prasad; Panigrahi, Durga Charan; Jha, Vivekananda; Patnaik, R Lokeswara; Sethy, Narendra Kumar

    2014-04-01

    Coarser mill tailings used as backfill to stabilize the stoped out areas in underground uranium mines is a potential source of radon contamination. This paper presents the quantitative assessment of radon emanation from the backfilled tailings in Jaduguda mine, India using a cylindrical accumulator. Some of the important parameters such as (226)Ra activity concentration, bulk density, bulk porosity, moisture content and radon emanation factor of the tailings affecting radon emanation were determined in the laboratory. The study revealed that the radon emanation rate of the tailings varied in the range of 0.12-7.03 Bq m(-2) s(-1) with geometric mean of 1.01 Bq m(-2) s(-1) and geometric standard deviation of 3.39. An increase in radon emanation rate was noticed up to a moisture saturation of 0.09 in the tailings, after which the emanation rate gradually started declining with saturation due to low diffusion coefficient of radon in the saturated tailings. Radon emanation factor of the tailings varied in the range of 0.08-0.23 with the mean value of 0.21. The emanation factor of the tailings with moisture saturation level over 0.09 was found to be about three times higher than that of the absolutely dry tailings. The empirical relationship obtained between (222)Rn emanation rate and (226)Ra activity concentration of the tailings indicated a significant positive linear correlation (r = 0.95, p < 0.001). This relationship may be useful for quick prediction of radon emanation rate from the backfill material of similar nature. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Soil gas radon response to environmental and soil physics variables

    International Nuclear Information System (INIS)

    Thomas, D.M.; Chen, C.; Holford, D.

    1991-01-01

    During the last three years a field study of soil gas radon activities conducted at Poamoho, Oahu, has shown that the primary environmental variables that control radon transport in shallow tropical soils are synoptic and diurnal barometric pressure changes and soil moisture levels. Barometric pressure changes drive advective transport and mixing of soil gas with atmospheric air; soil moisture appears to control soil porosity and permeability to enhance or inhibit advective and diffusive radon transport. An advective barrier test/control experiment has shown that advective exchange of soil gas and air may account for a substantial proportion of the radon loss from shallow soils but does not significantly affect radon activities at depths greater than 2.3 m. An irrigation test/control experiment also suggests that, at soil moisture levels approaching field capacity, saturation of soil macroporosity can halt all advective transport of radon and limit diffusive mobility to that occurring in the liquid phase. The results of the authors field study have been used to further refine and extend a numerical model, RN3D, that has been developed by Pacific Northwest Laboratories to simulate subsurface transport of radon. The field data have allowed them to accurately simulate the steady state soil gas radon profile at their field site and to track transient radon activities under the influence of barometric pressure changes and in response to changes in soil permeability that result from variations in soil moisture levels. Further work is continuing on the model to enable it to properly account for the relative effects of advective transport of soil gas through cracks and diffusive mobility in the bulk soils

  10. Radon and material radiopurity assessment for the NEXT double beta decay experiment

    Energy Technology Data Exchange (ETDEWEB)

    Cebrián, S.; Dafni, T.; González-Díaz, D.; Herrera, D. C.; Irastorza, I. G.; Luzón, G.; Ortiz de Solórzano, A.; Villar, J. A. [Laboratorio de Física Nuclear y Astropartículas, Universidad de Zaragoza, C/ Pedro Cerbuna 12, 50009 Zaragoza (Spain); Laboratorio Subterráneo de Canfranc, Paseo de los Ayerbe s/n, 22880 Canfranc Estación, Huesca (Spain); Pérez, J. [Instituto de Física Teórica, UAM/CSIC, Campus de Cantoblanco, 28049 Madrid (Spain); Bandac, I. [Laboratorio Subterráneo de Canfranc, Paseo de los Ayerbe s/n, 22880 Canfranc Estación, Huesca (Spain); Labarga, L. [Dpto. de Física Teórica, Universidad Autónoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain); Álvarez, V.; Cárcel, S.; Cervera, A.; Díaz, J.; Ferrario, P.; Gómez-Cadenas, J. J.; Laing, A.; Liubarsky, I.; López-March, N. [Instituto de Física Corpuscular, CSIC & Universitat de València, C/ Catedrático José Beltrán, 2, 46980 Paterna, Valencia (Spain); and others

    2015-08-17

    The ”Neutrino Experiment with a Xenon TPC” (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in {sup 136}Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.

  11. Particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist Route “Liczyrzepa” Mine in Kowary Adit

    Directory of Open Access Journals (Sweden)

    Wołoszczuk Katarzyna

    2018-01-01

    Full Text Available Central Laboratory for Radiological Protection, in cooperation with Central Mining Institute performed measurements of radon concentration in air, potential alpha energy concentration (PAEC, particle size distribution of the radon progeny and ambient aerosols in the Underground Tourist-Educational Route “Liczyrzepa” Mine in Kowary Adit. A research study was developed to investigate the appropriate dose conversion factors for short-lived radon progeny. The particle size distribution of radon progeny was determined using Radon Progeny Particle Size Spectrometer (RPPSS. The device allows to receive the distribution of PAEC in the particle size range from 0.6 nm to 2494 nm, based on their activity measured on 8 stages composed of impaction plates or diffusion screens. The measurements of the ambient airborne particle size distribution were performed in the range from a few nanometres to about 20 micrometres using Aerodynamic Particle Sizer (APS spectrometer and the Scanning Mobility Particle Sizer Spectrometer (SMPS.

  12. Uranium City radiation reduction program: further studies on remedial measures and radon infiltration routes for houses with block walls

    International Nuclear Information System (INIS)

    Leung, M.K.

    1980-01-01

    This report describes the results of tests of partial sealing of concrete block walls to prevent radon infiltration into houses in Uranium City, and gives the results of studies of radon migration through concrete block walls. Results of some laboratory tests on the effectiveness of concrete blocks as a radon barrier are included

  13. A comparison study between radon concentration in schools and other workplaces

    International Nuclear Information System (INIS)

    Clouvas, A.; Xanthos, S.

    2012-01-01

    The Nuclear Technology Laboratory of the Aristotle Univ. of Thessaloniki has since 1999 an open research project of indoor radon measurements in Greek workplaces. Since now 1380 measurements in 690 workplaces have been performed. Most (75 %) of the workplaces were offices in schools. The remaining 25 % were offices, mainly in public buildings. In the present study, a possible correlation between radon concentration in schools and other workplaces is investigated and discussed. (authors)

  14. Radon depletion in xenon boil-off gas

    Energy Technology Data Exchange (ETDEWEB)

    Bruenner, S.; Cichon, D.; Lindemann, S.; Undagoitia, T.M.; Simgen, H. [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany)

    2017-03-15

    An important background in detectors using liquid xenon for rare event searches arises from the decays of radon and its daughters. We report for the first time a reduction of {sup 222}Rn in the gas phase above a liquid xenon reservoir. We show a reduction factor of >or similar 4 for the {sup 222}Rn concentration in boil-off xenon gas compared to the radon enriched liquid phase. A semiconductor-based α-detector and miniaturized proportional counters are used to detect the radon. As the radon depletion in the boil-off gas is understood as a single-stage distillation process, this result establishes the suitability of cryogenic distillation to separate radon from xenon down to the 10{sup -15} mol/mol level. (orig.)

  15. Radon in geological medium

    Energy Technology Data Exchange (ETDEWEB)

    Hricko, J [GEOCOMPLEX, a.s., Bratislava (Slovakia)

    1996-12-31

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a{sub v} has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km{sup 2}. The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a{sub v} > 50 kBq/m{sup 3}). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs.

  16. Radon in geological medium

    International Nuclear Information System (INIS)

    Hricko, J.

    1995-01-01

    The paper presented deals with behavior of the radon in geological medium and with some results of the radon survey in Bratislava and Kosice regions. 1) The a v has been detected in the holes 0.80 m deep. The density of observations - 3 reference areas (one represents 20 stations) per 1 km 2 . The radon risk maps in 1:25000 and 1:50000 scales have been compiled. The 56.8% of the project area lies in low radon risk, 37.6% in medium radon risk and 5.6% in high radon risk. Follow-up monitoring of the equivalent volume radon activity (EVRA) at the flats, located in the areas with high radon risk of the surface layer, has showed values several times higher than Slovak limits (Marianka, Raca, Vajnory). The evidence that neotectonic is excellent medium for rising up emanation to the subsurface layer, is shown on the map. The tectonic zone of Liscie udolie in Bratislava-Karlova Ves area has been clearly detected by profile radon survey (a v > 50 kBq/m 3 ). 2) At present, northern half of the area of Kosice in question was covered by radon survey. The low and medium radon risks have been observed here, while localities with high radon risk are small in extent. The part of radon risk and soil permeability map from northern Kosice area is shown. (J.K.) 3 figs., 2 refs

  17. Cost effectiveness of radon mitigation in Canada

    International Nuclear Information System (INIS)

    Letourneau, E.G.; Krewski, D.; Zielinski, J.M.; McGregor, R.G.

    1992-01-01

    This paper examines the cost effectiveness of comprehensive strategies for reducing exposure to radon gas in indoor air in Canadian homes. The analysis is conducted within the context of a general framework for risk management programme evaluation which includes well-known evaluation techniques such as cost effectiveness and cost-benefit analyses as special cases. Based on this analysis, it is clear that any comprehensive programme to reduce exposure to environmental radon will be extremely expensive, and may not be justifiable in terms of health impact, particularly when considered in relation to other public health programmes. Testing of homes at the point of sale and installing sub-slab suction equipment to reduce exposure to indoor radon where necessary appears to be a relatively cost-effective radon mitigation strategy. In general, radon mitigation was found to be most cost effective in cities with relatively high levels of radon. (author)

  18. Novel Radon Sub-Slab Suctioning System

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    2013-01-01

    A new principle for radon protection is currently presented which makes use of a system of horizontal pressurised air ducts located within the lower part of the rigid insulation layer of the ground-floor slab. The function of this system is based on the principles of pressure reduction within...... a grid of horizontal air ducts with low pressure which are able to remove air and radon from the ground. Results showed the system to be effective in preventing radon infiltrating from the ground through the ground-floor slab, avoiding high concentrations of radon being accumulated inside houses....... For the system to be effective, the pressure within the ducts must be lower than the pressure inside the house. The new principle was shown to be effective in preventing radon from polluting the indoor air by introducing low pressure in the horizontal grid of air ducts. A lower pressure than the pressure inside...

  19. Radiation exposure due to radon and radon daughters

    International Nuclear Information System (INIS)

    Ullmann, W.

    1976-01-01

    Underground miners working over long periods of time in mines with a high content of radon and radon daughters belong to that group of occupationally exposed persons who are subject to the greatest somatic risk, with values especially high if the permissible dose limits are exceeded. Follwing an overview of the permissible limits currently in use for radon and radon daughters as well as the results of examinations performed in nationally-owned underground mining of the G.D.R., considerations are presented on the measuring quantities requisite for statistical, control and safety measurements in this field. Finally, conclusions are drawn concerning the measuring procedures and instruments to be employed for practical work. (author)

  20. AlphaGUARD, the new reference for continuous radon monitoring in air, soil, gas, water and material

    International Nuclear Information System (INIS)

    Roessler, F.; Buerkin, W.; Villert, J.

    2016-01-01

    The company Saphymo GmbH has more than 25 years of experience in the field of radon measurement. More than 20 years ago Saphymo developed the professional and robust radon monitor AlphaGUARD, quickly recognized as a standard for reliable and continuous measurements of the radon concentration. Today AlphaGUARD is internationally established as the reference in radon measurement. Following up on this success story the new generation of AlphaGUARD can now be presented. Based on the excellent measurement characteristics of its predecessor the new AlphaGUARD combines the well-proven principle of the pulse ionisation chamber with new and additional features. The robust housing is oriented on the well-proven design of the predecessor and includes now an integrated flow controlled and powerful pump. The instrument can be operated in flow as well as in diffusion mode (without pump). Via the new large display and the intuitive menu navigation all measurement data can be retrieved. The presentation of time series in charts is possible as well as the parametrisation of the instrument. A wide range of accessories, developed in cooperation with various radon experts of universities and laboratories, enables the user a varied and flexible application of the AlphaGUARD: Measurement of the radon concentration in air (radon, thoron, radon progenies), in water (sampling and time resolved measurements) and in soil (soil gas measurements, exhalation measurements), emanation measurements from material, multi spot measurement, online measurement with remote data transmission via Ethernet/DSL, Bluetooth, Wi-Fi, GPRS/3G or satellite. Due to its high sensitivity and its fast and linear response over a large measuring range the AlphaGUARD is excellently suited for calibration laboratories. Furthermore the AlphaGUARD enables ideal prerequisites for field applications: robust housing for operations under harsh conditions, long battery life for the measurement at any location, low

  1. BGS Radon Protective Measures GIS

    International Nuclear Information System (INIS)

    Appleton, D.; Adlam, K.

    2000-01-01

    The British Geological Survey Radon Protective Measures Geographical Information System is described. The following issues are highlighted: Identification of development sites where radon protection is required in new dwellings; Mapping radon potential on the basis of house radon and geology; Radon Protective Measures GIS; Radon site reports; and Follow-up radon protective measures sire reports

  2. Laboratory studies on the removal of radon-born lead from KamLAND's organic liquid scintillator

    Science.gov (United States)

    Keefer, G.; Grant, C.; Piepke, A.; Ebihara, T.; Ikeda, H.; Kishimoto, Y.; Kibe, Y.; Koseki, Y.; Ogawa, M.; Shirai, J.; Takeuchi, S.; Mauger, C.; Zhang, C.; Schweitzer, G.; Berger, B. E.; Dazeley, S.; Decowski, M. P.; Detwiler, J. A.; Djurcic, Z.; Dwyer, D. A.; Efremenko, Y.; Enomoto, S.; Freedman, S. J.; Fujikawa, B. K.; Furuno, K.; Gando, A.; Gando, Y.; Gratta, G.; Hatakeyama, S.; Heeger, K. M.; Hsu, L.; Ichimura, K.; Inoue, K.; Iwamoto, T.; Kamyshkov, Y.; Karwowski, H. J.; Koga, M.; Kozlov, A.; Lane, C. E.; Learned, J. G.; Maricic, J.; Markoff, D. M.; Matsuno, S.; McKee, D.; McKeown, R. D.; Miletic, T.; Mitsui, T.; Motoki, M.; Nakajima, Kyo; Nakajima, Kyohei; Nakamura, K.; O`Donnell, T.; Ogawa, H.; Piquemal, F.; Ricol, J.-S.; Shimizu, I.; Suekane, F.; Suzuki, A.; Svoboda, R.; Tajima, O.; Takemoto, Y.; Tamae, K.; Tolich, K.; Tornow, W.; Watanabe, Hideki; Watanabe, Hiroko; Winslow, L. A.; Yoshida, S.

    2015-01-01

    The removal of radioactivity from liquid scintillator has been studied in preparation of a low background phase of KamLAND. This paper describes the methods and techniques developed to measure and efficiently extract radon decay products from liquid scintillator. We report the radio-isotope reduction factors obtained when applying various extraction methods. During this study, distillation was identified as the most efficient method for removing radon-born lead from liquid scintillator.

  3. 1981 radon barrier field test at Grand Junction uranium mill tailings pile

    International Nuclear Information System (INIS)

    Hartley, J.N.; Gee, G.W.; Baker, E.G.; Freeman, H.D.

    1983-04-01

    Technologies to reduce radon released from uranium mill tailings are being investigated by Pacific Northwest Laboratory as part of the Department of Energy's Uranium Mill Tailings Remedial Action Project (UMTRAP) Technology development program. These technologies include: (1) earthen cover systems, (2) multilayer cover systems, and (3) asphalt emulsion radon barrier systems. During the summer of 1981, a field test was initiated at the Grand Junction, Colorado, uranium tailings pile to evaluate and compare the effectiveness of each radon barrier system. Test plots cover about 1.2 ha (3 acres). The field test has demonstrated the effectiveness of all three cover systems in reducing radon release to near background levels ( 2 s - 1 ). In conjunction with the field tests, column tests (1.8 m diameter) were initiated with cover systems similar to those in the larger field test plots. The column tests allow a direct comparison of the two test procedures and also provide detailed information on radon transport

  4. International intercalibration and intercomparison programme for radon, thoron and daughters measuring equipment. Part. 1: Radon measurement

    International Nuclear Information System (INIS)

    Knutson, E.O.; Solomon, S.B.

    1986-01-01

    The International Intercalibration and Intercomparison Programme for Radon, Thoron and Daughters Monitoring Equipment, abbreviated IIIP, is a program organized jointly by Nuclear Energy Agency of the Organization for Economic Cooperation and Development and the Radiation Protection Research Programme of the Commission of European Communities. The broad purpose of the IIIP is to determine if the somewhat diverse calibration procedures used in different countries are equivalent. The general approach was to select four regional reference laboratories and entrust them with the details of project definition and execution. The four selected laboratories are: Australian Radiation Laboratory, US DOE Environmental Measurements Laboratory, UK National Radiation Protection Board, US DOI Bureau of Mines. The Organizing Committee that selected the four laboratories remained intact and served an oversight function in all work to date

  5. Radon in the indoor of habitable and workable zones in the Estado de Mexico

    International Nuclear Information System (INIS)

    Pena, P.; Segovia, N.; Gaso, M.I.; Ponciano, G.

    2003-01-01

    The levels of the radon concentration and of suspended particles in the air of the indoor house-room and of laboratories, like part of a study related with the impact of the components of the tobacco smoke in the health of the active and passive smokers. The measures of the radon concentration were carried out with Honeywell A9000A systems and the fluctuations in the concentration and particle size they were determined with a Personal Measurer for the Data Acquisition of Particles in Real Time. The average value of the radon concentration inside the house-room was of 40 Bq m -3 , observing frequently radon peaks superior to 148 Bq m -3 . In the offices and laboratories, especially in those with little ventilation, the radon gas concentration showed superior values to the internationally established limits. The average value in 24 hours, of the particles (PM 10 ) inside the houses of smokers it was of 0. 751 ± 0.420 mg m -3 , being reached concentrations so high as 1. 6 mg m -3 , which is an order of superior magnitude to the maximum permissible limit of PM 10 (0.150 mg m -3 ), settled down by the Mexican Legislation. (Author)

  6. Radon Measurements in Vojvodina

    International Nuclear Information System (INIS)

    Bikit, I.; Bikit, K.; Forkapic, S.; Mrda, D.; Nikolov, J.; Todorovic, N.; Veskovic, M.

    2013-01-01

    Recent analyses of epidemiological studies of lung cancer risk from residential exposures demonstrate a statistically significant increase per unit of exposure below average annual concentrations of about 200 Bq/m 3 . Indoor radon measurements performed in Novi Sad in about 400 houses and flats are presented and discussed in this paper. By measuring gamma-activity of radon daughters, radon activity concentration was determined to be 50 Bq/m 3 . In Vojvodina region indoor radon levels were measured by alpha track detectors CR-39 on about 3000 locations during the winter seasons in the period of three years (2003-2005). The main aim of the present study was to explore the critical group of population for radon exposure and to estimate maximal annual doses. Existing radon maps which identify regions with elevated radon levels will improve data collection and analysis for the future radon campaigns. Collaboration on the JRC program of European indoor radon map and implementation of grid system are also discussed.(author)

  7. Asphalt emulsion radon barrier systems for uranium mill tailings - a summary of the technology

    International Nuclear Information System (INIS)

    Baker, E.G.; Hartley, J.N.; Freeman, H.D.

    1983-11-01

    Pacific Northwest Laboratory (PNL), has developed an asphalt emulsion cover system to reduce the release of radon from uranium mill tailings. The system has been field-tested at the tailings site in Grand Junction, Colorado. Results from laboratory and field tests indicate that this system effectively reduces radon release to near-background levels ( -2 s -1 ) and has the properties required for long-term effectiveness and stability. Engineering specifications have been developed, and a cost analysis indicates that asphalt emulsion covers are competitive with other cover systems. 6 references, 2 figures, 4 tables

  8. Study of the behavior of automatic track detectors for radon determination

    International Nuclear Information System (INIS)

    Moreno C, A.

    1997-01-01

    Both the alpha decay and the alpha and beta emitting radon daughters, may affect the living cells. In this thesis, experiments have been performed to study the response of environmental radon using different alpha particle detectors. A study was performed both in the laboratory and in the field of two kinds of detectors: a) Passive solid state nuclear track detectors, LR 115 type II, capable to integrate the alpha particles in a given period of time and, b) an automatic active detector, Clipperton, that continuously accumulate the alpha counting from radon decay. LR-115 track detectors were exposed in the laboratory to alpha particles from a radioactive source and a controlled radon atmosphere. The detectors were also exposed to electrons from an electron accelerator. The number of alpha tracks in the detectors were evaluated with two kinds of spark counters. The response of the track detectors as a function of the number of alpha tracks showed a reproducibility of 92%, and the effect of electron doses showed that the bulk etching velocity varied as a function of the electron dose. Additionally some changes were introduced in an SSNTD exchanger, exposed to the radon chamber in order to reduce the background in the non exposed positions. A conversion factor of 0.016 tracks/cm 2 . 10h per Bq/m 3 was obtained. The response of the two spark counters was similar. Field soil radon determinations were performed with track detectors during 11 months and with the active detector during 5 months with exposures each month and each hour respectively. When calculated for the same time periods exposure the response of both systems was similar. However differences were quite striking in the patterns of short and long term exposure periods since short term fluctuations are explicitly shown with the active detector while integrated within the passive one. (Author)

  9. Radon and cancer

    International Nuclear Information System (INIS)

    2011-01-01

    This publication proposes an overview on what is known about the carcinogenic effect of radon. It recalls the origin of radon, its presence in the environment, and its radioactivity. It comments data on the relationship between exposure to radon and lung cancer, and with other forms of cancer. It discusses the role of the exposure level, and the cases of professional and domestic exposure with respect to these risks. It indicates the hazardous areas in France which are well identified, outlines that smokers are more likely victims of risks related to radon, that this risk is still underrated and underestimated (notably by the public). It gives an overview of existing regulations regarding exposure to radon, of public health policies and national plans concerning radon, and recalls some WHO recommendations

  10. Occupational radon expositions during cleaning processes of water reservoirs

    International Nuclear Information System (INIS)

    Hingmann, H.; Ehret, V.; Hegenbart, L.; Krieg, K.

    2002-01-01

    According to the new German ''Strahlenschutzverordnung'' (Radiation Protection Directive) the annual dose due to the exposition to radon has to be estimated for employees of water works. This includes employees of service companies. While the job of employees of water works usually covers a broad spectrum of different activities, employees of service companies may spend a considerable amount of time of their total working hours cleaning water reservoirs. This investigation is concerned with this type of employees. The radon exposition of one or more cleaning processes were determined by passive dosimeters. The mean radon concentration was calculated for the duration of the cleaning process. In some cases, members of the project team accompanied cleaning processes and performed stationary radon measurements on site. Sometimes, parallel to the passive dosimeters, electronic dosimeters were used to measure personal exposure. The results - and results from additional laboratory reference measurements - are compared. All results until January 2002 are considered. The project still goes on and will end in summer of 2002. Experiences made during this investigation are described in the end of this report. (orig.)

  11. The Castleisland radon Survey (Sw Ireland)

    Energy Technology Data Exchange (ETDEWEB)

    Organo, C. [Radiological Protection Institute of Ireland, Dublin (Ireland); O' sullivan, F. [London Univ. College, Dept of Geomatic Engineering, London, (United Kingdom)

    2006-07-01

    Full text: In September 2003, following the identification of a house near Castleisland in County Kerry (Sw Ireland) with a seasonally adjusted annual average radon concentration of 49,000 Bq/m{sup 3}, the Radiological Protection of Ireland (R.P.I.I.) undertook to carry out a localised radon survey, the so-called 'Castleisland Radon Survey' (C.R.S.). The aim was to investigate the possibility that similarly extreme radon concentrations could be present in other houses in the surrounding area. A studied area of 400 km{sup 2} was designated around the town of Castleisland, divided in four 10 x 10 km{sup 2} grid squares, and all of the approximately 2,500 householders living in this area were invited to participate. Four hundred and eighteen householders responded to the invitation (17% response rate) but only 383 completed the survey. Fourteen percent of these 383 homes were found to have an annual average radon concentration above the Irish national Reference Level for domestic dwellings of 200 Bq/m{sup 3} while 2% were found to be above 800 Bq/m{sup 3}. An arithmetic mean of 147 Bq/m{sup 3} and a geometric mean of 70 Bq/m{sup 3} were calculated for the four studied grid squares. These can be compared with the respective values of 98 and 56 Bq/m3 calculated for the same area by the Irish National Radon Survey (N.R.S.). Similar trends are observed on a grid square by grid square basis where in one of them in particular, the C.R.S. allowed us to predict that 21% of all houses would have radon concentrations in excess of 200 Bq/m{sup 3}, against 6% predicted by the N.R.S.. This clearly indicates that the extent of the radon problem in the area has been underestimated by the N.R.S.. Two of the four grid squares investigated are currently designated as High Radon Areas (where 10% or more of all houses are predicted to exceed 200 Bq/m{sup 3}) based on the results from the N.R.S.. If one was to use predictions based on the results from the C.R.S., all four grid

  12. Radon awareness in Ireland: a assessment of the effectiveness of radon road shows

    International Nuclear Information System (INIS)

    Synnott, H.

    2006-01-01

    Full text: In late 2004 the Radiological Protection Institute of Ireland (R.P.I.I.) initiated a series of radon road shows in areas designated as High Radon Areas 1 in the R.P.I.I. s national radon survey of homes. The main objective of these road shows was to provide information to a local audience on the risks of exposure to radon. These road shows target both employers and householders. Each road show has the same general format. A presentation and/or meeting with a major employer representative group within the area. The purpose is to make employers aware of the risks associated with exposure to radon in the workplace and to highlight their obligations under current Irish health and safety legislation regarding radon in the workplace. An information stand on radon manned by R.P.I.I. staff members in a local shopping centre or other similar area. This provides those concerned about radon with accessible information on radon exposure risks, how to measure radon and the steps a home owner could take to reduce radon concentrations where necessary. Where possible R.P.I.I. staff members visit one or more schools in the general area. A short presentation on radon was given to students and students were given an opportunity to asks questions Maximizing media exposure to publicize our visits is vital to the success of these visits. Each visit is preceded by a Press Release whose main aim is to brief local and national media on the radon issue so as to achieve maximum publicity mainly through radio and television coverage. In general the media are very interested in the whole radon area and R.P.I.I. staff members have given 57 radio and 10 television interviews to date since the commencement of this initiative. The four road shows carried out to date have been successful in encouraging householders to carry out radon measurements. Since the start of the road shows to the present, the R.P.I.I. has seen a 44% increase in the number of householders requesting radon

  13. Numerical and analytical assessment of radon diffusion in various media and potential of charcoal as radon detector

    Science.gov (United States)

    Rybalkin, Andrey

    Numerical assessments of radon diffusion together with analytical estimates for short-time and long-time exposure were the first objective of this thesis with the goal to demonstrate how radon propagates in various media. Theoretical predictions were compared to numerical simulations, and obtained values of total radon activities inside each material match quite well with the analytical estimates. These estimates, for activated and nonactivated charcoal, were then used to evaluate the possibility of designing a charcoal system to be used as a radon detector. Another objective was to use nonactivated charcoal samples and measure the level of radon accumulation, and use these data to estimate radon diffusion and adsorption coefficients. The analytical approach was developed to estimate these values. Radon adsorption coefficient in nonactivated charcoal was found to be from 0.2 to 0.4 m3/kg. Radon diffusion coefficient for nonactivated charcoal is in the range of 1.2×10-11 to 5.1×10-10 m2/s in comparison to activated charcoal with adsorption coefficient of 4 m3/kg and diffusion coefficient of 1.43×10-9 m2/s. The third objective was to use GEANT4 numerical code to simulate decay of 238U series and 222Rn in an arbitrary soil sample. Based on that model, the goal was to provide a guideline for merging GEANT4 radioactive decay modeling with the diffusion of radon in a soil sample. It is known that radon can be used as an earthquake predictor by measuring its concentration in groundwater, or if possible, along the faults. Numerical simulations of radon migration by diffusion only were made to estimate how fast and how far radon can move along the fault strands. Among the known cases of successful correlations between radon concentration anomalies and earthquake are the 1966 Tashkent and 1976 Songpan-Pingwu earthquakes. Thus, an idea of radon monitoring along the Wasatch Fault, using system of activated/nonactivated charcoals together with solid state radon detectors is

  14. Radon potential mapping of the Tralee-Castleisland and Cavan areas (Ireland) based on airborne gamma-ray spectrometry and geology.

    Science.gov (United States)

    Appleton, J D; Doyle, E; Fenton, D; Organo, C

    2011-06-01

    The probability of homes in Ireland having high indoor radon concentrations is estimated on the basis of known in-house radon measurements averaged over 10 km × 10 km grid squares. The scope for using airborne gamma-ray spectrometer data for the Tralee-Castleisland area of county Kerry and county Cavan to predict the radon potential (RP) in two distinct areas of Ireland is evaluated in this study. Airborne data are compared statistically with in-house radon measurements in conjunction with geological and ground permeability data to establish linear regression models and produce radon potential maps. The best agreement between the percentage of dwellings exceeding the reference level (RL) for radon concentrations in Ireland (% > RL), estimated from indoor radon data, and modelled RP in the Tralee-Castleisland area is produced using models based on airborne gamma-ray spectrometry equivalent uranium (eU) and ground permeability data. Good agreement was obtained between the % > RL from indoor radon data and RP estimated from eU data in the Cavan area using terrain specific models. In both areas, RP maps derived from eU data are spatially more detailed than the published 10 km grid map. The results show the potential for using airborne radiometric data for producing RP maps.

  15. An evaluation of passive methods for measurement of radon in dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Lind, B.; Kolstad, A.K.

    1989-01-01

    During the last ten years, different methods have been developed for the measurement of radon in indoor air. In this report the different methods in use by private firms in Norway have been compared. The results of the study show that the methods are quite different in regard to integration time, detection limit and reliability in measurements of radon in indoor air. In 1988 the National Institute of Radiation Hygiene gave directives on the performance of such measurements. In these directives, minimum limits have been set for integration time (7 days) for methods to be used in evaluations of remedial actions. In this report the results from a simple, anonymeous reliability test are reported. The test covered the private firms offering radon meassurement services in Norway. The frequently reported weaknesses by the charcoal method were confirmed in the study. The directives on radon measurements in dwellings are presented. 73 refs.; 11 figs.; 5 tabs

  16. Project Radon

    International Nuclear Information System (INIS)

    Ekholm, S.

    1988-01-01

    The project started in March 1987. The objective is to perform radon monitoring in 2000 dwellings occupied by people employed by State Power Board and to continue to contribute to the development of radon filters. The project participates in developing methods for radon measurement and decontamination and in adapting the methods to large scale application. About 400 so called radon trace measurements (coarse measurement) and about 10 action measurements (decontamination measurement) have been made so far. Experience shows that methods are fully applicable and that the decontamination measures recommended give perfectly satisfactory results. It is also established that most of the houses with high radon levels have poor ventilation Many of them suffer from moisture and mould problems. The work planned for 1988 and 1989 will in addition to measurements be directed towards improvement of the measuring methods. An activity catalogue will be prepared in cooperation with ventilation enterprises. (O.S.)

  17. Measured radon inside housings the Republic Argentina

    International Nuclear Information System (INIS)

    Canoba, A.; Arnaud, M.; Lopez, F.; Oliveira, A.A.

    1998-01-01

    They have been measured the radon concentration in houses in different city's in Argentina Republic. For they were used it as method mensuration detectors appearances nuclear detecting electrets and detectors based on the adsorption radon in activated carbon

  18. Volume traps - a new retrospective radon monitor

    International Nuclear Information System (INIS)

    Oberstedt, S.; Vanmarcke, H.

    1994-11-01

    A new method to trace back average radon concentrations in dwellings over several decades in time has been developed. This retrospective radon monitor is based on the measurement of the alpha activity of 210 Po deposited in volume traps, for example spongy materials used for mattresses and cushions. Polyester samples with different densities have been exposed to radon-laden air. The exposures correspond to characteristic radon concentrations between 390 Bq/m 3 and 3.9 Bq/m 3 over a 20 years period. The precision in converting the 210 Po signal to the radon exposure has been improved by more than one order of magnitude compared to other common techniques. It is shown that this very sensitive method may be applied to almost all types of volume traps used in households

  19. A Radon Chamber without Radium Source for Detector Calibration and Radon Measurements

    International Nuclear Information System (INIS)

    Al-Azmi, D.; Karunakara, N.

    2008-01-01

    A radon chamber of volume 216 liters was designed and constructed for calibration of radon detectors and radon test measurements. The main feature of this chamber is that the active 226 Ra source, to generate the 222 Rn inside the chamber volume, is not required. Instead, 222 Rn from soil gas is utilized for this purpose. The supply of radon comes from the soil gas. Soil gas is drawn from the soil to fill the chamber with high radon concentration levels (∼ 80 kBq/m3). Desired radon concentration levels can be obtained by drawing the soil gas for different time durations and/or flow rate (author)

  20. Radon reduction in waterworks

    International Nuclear Information System (INIS)

    Raff, O.; Haberer, K.; Wilken, R.D.; Funk, H.; Stueber, J.; Wanitschek, J.; Akkermann-Kubillus, A.; Stauder, S.

    2000-01-01

    The removal of radon from water using water aeration is one of the most effective methods for reducing radon in waterworks. Therefore, this report describes investigations on packed tower columns and shallow aeration devices and a method for mathematical modelling of gas exchange processes for dimensioning packed tower columns for radon removal. Moreover, possibilities for removing radon using active carbon filtration under waterworks typical conditions and for reducing indoor radon levels in waterworks are discussed. Finally, conclusions on the necessity of radon removal in German waterworks are drawn. (orig.) [de

  1. Residential radon survey in Finland

    International Nuclear Information System (INIS)

    Arvela, H.; Maekelaeinen, I.; Castren, O.

    1993-02-01

    The study measured the indoor radon concentration in the dwellings of 3074 persons, selected randomly from the central population register of Finland. Alpha track detectors and two consecutive half year measuring periods were used. The national mean of indoor radon concentration for persons living in low-rise residential buildings as well as blocks of flats was 145 and 82 Bq/m 3 , respectively. The mean for the total population was 123 Bq/m 3 . Based on the decision of the Ministry of Social Affairs and Health in 1992, the indoor radon concentration should not exceed 400 Bq/m 3 in already existing houses, the target for new construction being less than 200 Bq/m 3 . According to the study, the percentage of the Finnish population living in houses with an indoor radon concentration exceeding 200, 400 and 800 Bq/m 3 was 12.3 %, 3.6 % and 1.0 %

  2. Evaluation of radon concentration in dwellings and well water of Parana State-Brazil

    International Nuclear Information System (INIS)

    Correa, Janine Nicolosi

    2011-01-01

    Considering the growing interest of International Agencies and national Governmental organs in studies and measurements of radon activity in air, soil gas and ground water (mainly from artesian wells) as well as scarceness of such measurements at Brazilian territory, present studies were initiated by the Laboratory of Applied Nuclear Physics of Federal University of Technology - Parana (UTFPR) in collaboration with the Institute of Radiation Protection and Dosimetry (IRD) and the Center of Nuclear Technology Development (CDTN) of Brazilian Commission on Nuclear Energy (CNEN). This Collaboration started in 2003. Radon monitoring program is based mainly on use of Solid State Nuclear Track Detectors for radon activity measurements in air. Continuous electronic radon detectors are used for radon measurements in soil gas and water. Current work presents the results of indoor 222 Rn activity of dwellings and working places of Curitiba-PR and radon concentration in ground water samples from artesian wells from aquifers of the same area. The indoor measurements of radon activity were performed using Solid State Nuclear Track Detectors CR-39. After the exposition, CR-39 detectors were submitted to chemical development which permitted to make alpha particle tracks counting. The results of calibration of CR-39 together with efficiency of used exhalation chambers as well as alpha particle tracks chemical development procedure were performed in cooperation with CDTN and collaboration with the National Institute of Radiological Sciences (NIRS). The major part of indoor 222 Rn concentration in residences was found below 100 Bq/m3. In the case of working places, all measurements present 222 Rn concentration bellow 100 Bq/m3. The studies of radon activity in water were performed using the samples of water from artesian wells submitted to recursive measurements by instant radon detector AlphaGUARD PQ2000 PRO during few weeks with intervals of about 4 days between each measurement

  3. Radon house doctor

    International Nuclear Information System (INIS)

    Nitschke, I.A.; Brennan, T.; Wadach, J.B.; O'Neil, R.

    1986-01-01

    The term house doctor may be generalized to include persons skilled in the use of instruments and procedures necessary to identify, diagnose, and correct indoor air quality problems as well as energy, infiltration, and structural problems in houses. A radon house doctor would then be a specialist in radon house problems. Valuable experience in the skills necessary to be developed by radon house doctors has recently been gained in an extensive radon monitoring and mitigation program in upstate New York sponsored by Niagara Mohawk Power Corporation and the New York State Energy Research and Development Authority. These skills, to be described in detail in this paper, include: (i) the use of appropriate instruments, (ii) the evaluation of the symptoms of a radon-sick house, (iii) the diagnostic procedures required to characterize radon sources in houses, (iv) the prescription procedures needed to specify treatment of the problem, (v) the supervision of the implementation of the treatment program, (vi) the check-up procedures required to insure the house cured of radon problems. 31 references, 3 tables

  4. A personal radon dosemeter

    International Nuclear Information System (INIS)

    Oberstedt, S.; Vanmarcke, H.

    1994-03-01

    In the last decade the radon issue has become one of the major problems of radiation protection. Animal studies as well as epidemiological studies showed an increased lung cancer risk. A new personal radon-dosemeter on the basis of a CR-39 (poly-allyl diglycol carbonate) track-etch detector has been developed. The read-out of the detectors is based on the image- processing technique. The actual efficiency of the new dosemeter, obtained with a semi-automatic personal-computer based image-analysis system, is 1.43 +/- 0.15 tracks/cm 2 /(kBq/m 3 h), which is about three times that of the widely used Karlsruhe-type detector based on polycarbonate detectors

  5. Large-scale radon hazard evaluation in the Oslofjord region of Norway utilizing indoor radon concentrations, airborne gamma ray spectrometry and geological mapping

    International Nuclear Information System (INIS)

    Smethurst, Mark Andrew; Strand, Terje; Sundal, Aud Venke; Rudjord, Anne Liv

    2008-01-01

    We test whether airborne gamma ray spectrometer measurements can be used to estimate levels of radon hazard in the Oslofjord region of Norway. We compile 43,000 line kilometres of gamma ray spectrometer data from 8 airborne surveys covering 10,000 km 2 and compare them with 6326 indoor radon measurements. We find a clear spatial correlation between areas with elevated concentrations of uranium daughters in the near surface of the ground and regions with high incidence of elevated radon concentrations in dwellings. This correlation permits cautious use of the airborne data in radon hazard evaluation where direct measurements of indoor radon concentrations are few or absent. In radon hazard evaluation there is a natural synergy between the mapping of radon in indoor air, bedrock and drift geology mapping and airborne gamma ray surveying. We produce radon hazard forecast maps for the Oslofjord region based on a spatial union of hazard indicators from all four of these data sources. Indication of elevated radon hazard in any one of the data sets leads to the classification of a region as having an elevated radon hazard potential. This approach is inclusive in nature and we find that the majority of actual radon hazards lie in the assumed elevated risk regions

  6. Radon and thoron progeny measurements using a portable radon sniffer

    International Nuclear Information System (INIS)

    Efendi, Z.; Jennings, P.

    1993-01-01

    A flexible version of the two-count method has been developed for use in rapid, inexpensive measurements of radon and thoron progeny working levels in residential and industrial premises in the Perth Metropolitan Area. The Method is adapted for use with a simple radon sniffer based on a low speed pump and an alpha counter. The flexibility of the method derives from the software, where some freedom is permitted in the selection of sampling times and post sampling analysis of the filters. This method has been tested on a variety of radioactive materials and it gives consistent, reliable results over a wide range of working levels. The results of a survey of Rn(222) and Rn(220) progeny levels in dwellings within the Perth Metropolitan Area are reported. This study shows that the mean concentration of indoor Rn(222) progeny was 4.7 mWL (17.4 Bq m -3 EEC) up to 23.3 mWL (86.4 Bq m -3 EEC). The mean thoron progeny concentration was 8.2 mWL (2.25 Bq m -3 EEC) with a range from 1 mWL (0.27 Bq m -3 EEC) to 64.5 mWL (17.74 Bq m -3 EEC). Using conversion factors of 0.061 mSv Bq -1 m -3 for Rn(222) progeny and 0.29 mSv Bq -1 m -3 for Rn(220) progeny respectively (UNSCEAR, 1982), it is estimated the average annual effective dose equivalent is 1.1 mSv for Rn(2220 and 0.6 mSv for Rn(220) respectively. 22 refs., 4 tabs., 1 fig

  7. Reasons for increasing radon concentrations in radon remediated houses

    International Nuclear Information System (INIS)

    Clavensjoe, B.

    1997-01-01

    The study comprises 31 single-dwelling houses where remedial actions were carried out in the 1980s. In all of them the radon concentrations have increased more than 30% according to recent control measurements. Radon sources are building material as well as the soil. The remedial actions dealt with ventilation systems, leakage through the basement floor, air cushions, sub-slab suction or radon wells according to the original problems. Causes for the increase varied: In many houses with soil radon problems, the installation of a normal mechanical ventilation system is not a good remedial action. In some houses on a ground with high permeability and high radon content in the soil air, the radon concentration may increase by the lowering of the indoor air pressure. In other houses the increase was a measurement effect, where sites/rooms were confused. Living related causes were identified in a number of cases, where fan speeds were reduced for energy conservation/noise reduction purposes or different use of windows airing had occurred. Extension of the dwelling space without changing the ventilation system caused the increase in one house. 23 refs

  8. Mitigation of radon and thoron decay products by filtration

    International Nuclear Information System (INIS)

    Wang Jin; Meisenberg, Oliver; Chen Yongheng; Karg, Erwin; Tschiersch, Jochen

    2011-01-01

    Inhalation of indoor radon ( 222 Rn) and thoron ( 220 Rn) decay products is the most important source of exposure to ionizing radiation for the human respiratory tract. Decreasing ventilation rates due to energy saving reasons in new buildings suggest additional active mitigation techniques to reduce the exposure in homes with high radon and thoron concentrations but poor ventilation. Filtration techniques with HEPA filters and simple surgical mask material have been tested for their potential to reduce the indoor exposure in terms of the total effective dose for mixed radon and thoron indoor atmospheres. The tests were performed inside an experimental room providing stable conditions. Filtration (at filtration rates of 0.2 h -1 and larger) removes attached radon and thoron decay products effectively but indoor aerosol as well. Therefore the concentration of unattached decay products (which have a higher dose coefficient) may increase. The decrease of the attached decay product concentrations could be theoretically described by a slowly decreasing exponential process. For attached radon decay products, it exhibited a faster but weaker removal process compared to attached thoron decay products (- 70% for attached radon decay products and - 80% for attached thoron decay products at a filtration rate of 0.5 h -1 with an HEPA filter). The concentration of unattached thoron decay products increased distinctly during the filtration process (+ 300%) while that of unattached radon decay products rose only slightly though at a much higher level (+ 17%). In the theoretical description these observed differences could be attributed to the different half-lives of the nuclides. Considering both effects, reduced attached and increased unattached decay product concentrations, filtration could significantly decrease the total effective dose from thoron whereas the overall effect on radon dose is small. A permanent filtration is recommended because of the slow decrease of the

  9. Outdoor radon variation in Romania

    International Nuclear Information System (INIS)

    Simion, Elena; Simion, Florin

    2008-01-01

    Full text: The results of a long-term survey (1992 - 2006) of the variations of outdoor radon concentrations in semi-natural location from Romania are reported in the present paper. Measurements, covering between two and four sessions of the day (morning, afternoon, evening and night), were performed on a daily bases by 37 Environmental Radioactivity Monitoring Stations from National Environmental Radioactivity Survey Network. The method used was based on indirect determination of outdoor radon from aerosol samples collected on glass micro-fibre filters by drawing the air through the filters. The sampling was performed in a fixed place at a height of 2 m above the ground surface. Total beta counting of aerosol samples collected was performed immediately and after 20 hours. Values recorded during the years of continuous measurement indicated the presence of several patterns in the long-term variation of outdoor radon concentration: diurnal, seasonal and annual variation. For diurnal variation, outdoor radon concentration shows a maximum values in the night (early hours) and minimum values by day (in the afternoon). On average, this maximum is a factor of 2 higher than the minimum. Late autumn - beginning of winter maximum and an early spring minimum are characteristic for seasonal patterns. In the long term a seasonal pattern was observed for diurnal variation, with an average diurnal maximum to minimum ratio of 1.33 in winter compared with 3.0 in the summer months. The variations of outdoor radon levels showed little correlation with the uranium concentration of the ground and were attributed to changes in soil moisture content. In dry seasons, because of the low precipitation, the soil was drying out in the summer allowing fractures to develop and radon to migrate easily through the ground. Depending on micro-climatic and geological conditions, outdoor radon average concentrations in different regions of Romania are from 1200 mBq/mc to 13065 mBq/mc. The smallest

  10. Blower door method in radon diagnostics

    International Nuclear Information System (INIS)

    Fronka, A.; Moucka, L.

    2004-01-01

    The idea of the radon transfer factor is commonly presented as the ratio of the building indoor radon concentration to the subsoil radon concentration. Ventilation and the pressure field over the whole building envelope, which varies in a time over a very wide range even in the same building, poses a major problem. Therefore a new approach based on the controlled conditions determining the soil air infiltration was developed. Radon in soil gas infiltrates into the building indoor environment particularly through cracks and other leakages in the structure providing the building contact with its subsoil. The infiltration is driven by the air pressure difference on the two sides of the structure. The pressure difference is caused by the stack effect and its value ranges from 1-2 Pa in family houses to some tens of Pa in higher buildings. Unfortunately, the pressure difference is very unstable under normal conditions, being affected by a host of parameters such as the height of the building, distribution and geometry of leakages, outdoor-indoor temperature difference, etc. Wind direction and velocity of the wind plays a major role. In our research the blower door method was applied in combination with a monitoring of the indoor radon concentration. The indoor-outdoor pressure difference and the pressure difference at the two sides of the screen shutter of the blower door fan are also measured. The blower door ensures a constant, evaluable air exchange rate. The fan power is regulated to provide a stable pressure difference within the range of roughly 5-100 Pa. This approach provides very well defined conditions allowing us to apply a constant ventilation-constant radon supply model. In such circumstances the dynamical changes of radon concentrations are very fast, and therefore a unique continual radon monitor was applied. The radon supply rate is evaluated from the radon steady state of the time course of radon concentration. The dependence of the radon supply rate on

  11. Radon concentration of waters in Greece and Cyprus

    Science.gov (United States)

    Nikolopoulos, D.; Vogiannis, E.; Louizi, A.

    2009-04-01

    Alpha Guard are connected via plastic radon proof tubes. Forced degassing of radon gas is performed by circulating the air in the set up with the use of a pump. Water sampling (to avoid radon escape) was driven by a strict protocol. Water taps were opened for 10 minutes before drawing the sample. Glass storage vessels of 200 to 1000 ml, with adjustment glass stoppers with standard NS 29/32 grounding, as well as sealing rings and granted security clamps for taper grounding, were completely filled slowly and immediately closed (to avoid the formation of air bubbles). Similar procedure (except tap opening) was followed for underground and surface waters. Laboratory measurements were performed at least one hour after drawing the sample in order to assure the full decay of any thoron content and to the minimum achievable time interval, so as the radon content to be the highest possible to allow higher precision. For the measurement the glass stopper was removed and immediately exchanged with the degassing cap. Afterwards water quantity was reduced to about half and measured. From the measurements, the mean annual equivalent dose rate (aEDr) delivered to stomach due to ingestion and the contribution to aEDr due to inhalation of radon in drinking water were calculated as using the EURATOM 2001 dose conversion factor (0.00144 mSv/Bq). Radon concentrations in drinking waters ranged between (1.1+/-0.5) Bq/L and (15+/4) Bq/L. Only three samples collected from the radon prone area of Arnea Chalkidikis presented high radon concentrations (120+/20 Bq/L, 320+/-40 Bq/L, 410+/-50 Bq/L). Radon concentrations in underground waters ranged between (1.2+/-0.7) Bq/L and (14.7+/-1.1) Bq/L. The corresponding concentration range in surface waters was (2.7+/-0.8) Bq/L and (24+/-6) Bq/L. The radon concentrations in thermal waters (some of which are used for drinking) were quite higher (in the range of (220+/-20) to (340+/-40) Bq/L). In both countries, no correlation of radon in underground waters

  12. Modelling and experimental study of the behavior of radon and radon decay products in an enclosure. Application to houses; Modelisation et etude experimentale du comportement du radon et de ses descendants dans une enceinte confinee. Application a une habitation

    Energy Technology Data Exchange (ETDEWEB)

    Gouronnec, A M

    1995-02-03

    Since the eighties, more and more studies were performed about radon and its decay products in houses with one of the aim being the estimation of the dose received by their inhabitants. Then, the principal objective of this work is to describe the behaviour of radon and its decay products within a dwelling. In the first part to the report, a few definitions are given and data from literature give an idea of indoor radon and radon decay products activities and/or size distribution. Aspects of dosimetry are presented too. In the second part of the work, a mathematical model, called `PRADDO` of Physic of Radon and radon Decay products in Domestic environment is developed on the basis of the classical model written by Jacobi in 1972. On the one hand, it has to predict radon decay products activities in systems consisting in one or more enclosure(s), from radon activity and from ambient aerosol concentration and size distribution. On the other hand, one part of the model is assigned to study the influence of the entry model parameters variation on the calculated quantities. Then, in the third part of the work, two experimental studies are realised in order to compare measurements to modelization. The first experimentation is a laboratory work, made on the test bench ICARE from IPSN, and the second one consists in describing the basement of an occupied house from Brittany. In the two cases, the comparison between experiments and modelling shows a good agreement if particles are present in the air, but any conclusion is made when is no aerosol in the enclosure. (author). 158 refs., 81 figs., 42 tabs.

  13. Analysis of separation test for automatic brake adjuster based on linear radon transformation

    Science.gov (United States)

    Luo, Zai; Jiang, Wensong; Guo, Bin; Fan, Weijun; Lu, Yi

    2015-01-01

    The linear Radon transformation is applied to extract inflection points for online test system under the noise conditions. The linear Radon transformation has a strong ability of anti-noise and anti-interference by fitting the online test curve in several parts, which makes it easy to handle consecutive inflection points. We applied the linear Radon transformation to the separation test system to solve the separating clearance of automatic brake adjuster. The experimental results show that the feature point extraction error of the gradient maximum optimal method is approximately equal to ±0.100, while the feature point extraction error of linear Radon transformation method can reach to ±0.010, which has a lower error than the former one. In addition, the linear Radon transformation is robust.

  14. An active radon sampling device for high humidity places

    Energy Technology Data Exchange (ETDEWEB)

    Legarda, F. [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda Urquijo s/n 48013 Bilbao (Spain); Idoeta, R., E-mail: raquel.idoeta@ehu.e [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda Urquijo s/n 48013 Bilbao (Spain); Alegria, N.; Herranz, M. [Department of Nuclear Engineering and Fluid Mechanics, University of the Basque Country (UPV/EHU), Alameda Urquijo s/n 48013 Bilbao (Spain)

    2010-01-15

    An active radon measurement device has been developed to be used in workplaces with a relative humidity of 100% for spot measurements of radon concentration. A mathematical model based on the convective-diffusive transport equation is used in the design of this system, which has been used to measure the radon concentration in the Pozalagua cave (Biscay, at Northern of Spain). From the obtained radon values the public and workers doses have been obtained.

  15. Radon: an environmental pollutant

    International Nuclear Information System (INIS)

    Mills, W.A.

    1979-01-01

    Radiological concerns with the disposal and use of mining and milling residues have heightened to the point that federal agencies are asking or being asked to formulate new regulactions for controlling radon daughters from a variety of sources - radioactivity previously considered to be part of our natural environment. Based on information derived from epidemiologic studies of underground miners, particularly uranium miners, the health impact on the general public is being projected. Depending on the assumptions made, these projections vary widely. Because of these variations in health risks, decisions on control measures have even wider implications on economic and social considerations. Thus the question: is radon an environmental pollutant. While not fully answering the question, recognizing the uncertainties in assessing and controlling radon daughters can put the question in better perspective

  16. The ORNL Indoor Air Quality Study: Re-cap, Context, and Assessment on Radon

    Energy Technology Data Exchange (ETDEWEB)

    Tonn, Bruce Edward [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Rose, Erin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ternes, Mark P. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-10-01

    As part of the retrospective evaluation of the U.S. Department of Energy s low-income Weatherization Assistance Program that was led by Oak Ridge National Laboratory (ORNL), an assessment of the impacts of weatherization on indoor air quality (IAQ) was conducted. This assessment included nearly 500 treatment and control homes across the country. Homes were monitored for carbon monoxide, radon, formaldehyde, temperature and humidity pre- and post-weatherization. This report focuses on the topic of radon and addresses issues not thoroughly discussed in the original IAQ report. The size, scope and rigor of the radon component of the IAQ study are compared to previous studies that assessed the impacts of weatherization on indoor radon levels. It is found that the ORNL study is by far the most extensive study conducted to date, though the ORNL results are consistent with the findings of the other studies. However, the study does have limitations related to its reliance on short-term measurements of radon and inability to attribute changes in radon levels in homes post-weatherization to specific weatherization measures individually or in combination.

  17. The heightened activity of radon in water analysis from Lounovice area, Czech Republic

    International Nuclear Information System (INIS)

    Thinova, L.; Berka, Z.; Fridrichova, L.; Kaderova, J.; Cernohorska, E.; Pokorna, T.; Kosar, V.; Patak, M.; Kracmarova, I.

    2004-01-01

    The Lounovice area is located approximately 20 km south-east of Prague. Radon activity in fresh water from drilled-wells, used for village water supply, ranges between 700 and 900 Bq/l, which exceeds the standard for drinkable water by a factor higher than 100. Therefore, water is treated by aeration before use. Some residents, however, use drinking water from their own wells. A comprehensive radon and natural radioactivity survey was therefore conducted in this area. Secondary school students were engaged in this survey within the 'Physics Week' scientific program for young physicists, run by the Czech Technical University in Prague every year. in year 2004. The program included the following items: Laboratory gamma spectrometric measurement of the bedrock; Radon activity measurement in water before and after the aeration process; Radon monitoring at workplaces of the water company (the values provided by ionization chamber instruments and semiconductor detector instruments were compared); Radon daughters measurement at workplaces of the water company; In situ gamma spectrometry; In situ effective dose rate measurement; and Determination of a 'radon index' in the neighborhood of a drilled well

  18. Smoking cessation programmes in radon affected areas: can they make a significant contribution to reducing radon-induced lung cancers?

    International Nuclear Information System (INIS)

    Denman, A.R.; Groves-Kirkby, C.J.; Timson, K.; Shield, G.; Rogers, S.; Phillips, P.S.

    2008-01-01

    Domestic radon levels in parts of the UK are sufficiently high to increase the risk of lung cancer in the occupants. Public health campaigns in Northamptonshire, a designated radon affected area with 6.3% of homes having average radon levels over the UK action level of 200 Bq m -3 , have encouraged householders to test for radon and then to carry out remediation in their homes, but have been only partially successful. Only 40% of Northamptonshire houses have been tested, and only 15% of householders finding raised levels proceed to remediate. Of those who did remediate, only 9% smoked, compared to a countywide average of 28.8%. This is unfortunate, since radon and smoking combine to place the individual at higher risk by a factor of around 4, and suggests that current strategies to reduce domestic radon exposure are not reaching those most at risk. During 2004-5, the NHS Stop Smoking Services in Northamptonshire assisted 2,808 smokers to quit to the 4-week stage, with some 30% of 4-week quitters remaining quitters at 1 year. We consider whether smoking cessation campaigns make significant contributions to radon risk reduction on their own, by assessing individual occupants' risk of developing lung cancer from knowledge of their age, gender, and smoking habits, together with he radon level in their house. The results demonstrate that smoking cessation programmes have significant added value in radon affected areas, and contribute a greater health benefit than reducing radon levels in the smokers' homes, whilst they remain smokers. Additionally, results are presented from a questionnaire-based survey of quitters, addressing their reasons for seeking help in quitting smoking, and whether knowledge of radon risks influenced this decision. The impact of these findings on future public health campaigns to reduce the impact of radon and smoking are discussed. (author)

  19. The role of house surveys in geological radon potential mapping

    International Nuclear Information System (INIS)

    Ball, K.

    1997-01-01

    Because radon levels vary widely between apparently identical buildings on the same geological unit, no map can predict the radon level in an individual building. Maps can, however, give the probability that a building in a particular locality is above a threshold of radon concentration such as a reference or action level. The probability may be calculated for a particular building type or for a mixture of building types. In the latter case the probability is in effect an estimate of the proportion of buildings above the threshold level. Alternatively maps can provide estimates of the mean radon levels in buildings by area. Maps showing the geographical variation in probability that new or existing building will exceed a radon reference level are used to prevent excessive exposures to radon. The information may be used in various ways, such as to target information campaigns encouraging measurement of radon levels in homes or to modify regulations for new buildings. The data which are used to provide the estimates of the proportion of buildings above a threshold may be radon measurements results from a sample of buildings, or may be indirect indicators such as ground radium concentrations, emanation coefficients and permeability measurements. Consistency in radon measurement protocols and detailed positional information are prerequisites for mapping radon prone areas based upon house data. Grouping building radon measurements by geological formation and superficial cover can produce radon potential maps which are more spatially accurate than grid square maps and more accurate in estimating numbers of homes affected than mapping based only on measuring geological and pedagogical properties

  20. Indoor radon measurements and radon prognosis for the province of Kymi, southeastern Finland

    International Nuclear Information System (INIS)

    Pennanen, M.; Maekelaeinen, I.; Voutilainen, A.

    1996-12-01

    The purpose of the regional radon prognosis is to classify areas with different levels of radon risk. The radon prognosis gives the percentages of future homes expected to have indoor radon concentrations exceeding the levels of 200 and 400 Bq/m 3 . It is assumed that no protection against the entry of radon is used in construction. In this study about 5900 indoor radon measurements made in single family houses, semi-detached houses and row houses were used. Data on the location, geology and construction of buildings were determined from maps and questionnaires. An empirical statistical model, the adjusted indoor radon measurements and geological data were used to assess the radon risk from soil and bedrock in different areas. The building sites of the province of Kymi were divided into thirteen sub-areas. The radon prognosis are calculated for the most radon-prone foundation types including 1) houses with a slab-on-grade and 2) houses with a basement or hillside houses with open stairwells between basement and first floor. The radon levels are generally greater in the western part of the area. The radon risk is highest in gravel-dominated esker areas in southwestern, western (in Pyhtaa, Kotka, Anjalankoski, litti, Valkeala) and central (Taipalsaari) parts of the area. The radon risk is also high in some bedrock and till areas, also in southwestern and western parts of the area. In these areas the level of 200 Bq/m 3 will be exceeded in 80 % of new houses. About half of the future houses in these areas will have indoor radon concentrations exceeding 400 Bq/m 3 . The radon risk is lowest in the eastern part of the province of Kymi in every soil type. In this area the level of 200 Bq/m 3 will be exceeded in 30 % of new houses. Below 10 % will exceed 400 Bq/m 3 . (orig.) (14 refs.)

  1. Radon as a groundwater tracer in Forsmark and Laxemar

    Energy Technology Data Exchange (ETDEWEB)

    Grolander, Sara

    2009-10-15

    caused by the homogenous radon concentrations measured in the Laxemar area. The radon concentrations in near surface water measured in Forsmark showed large variability with both low and high radon concentrations. This large variability in radon concentration could not be explained by the flow pattern of the groundwater since no clear correlation between radon concentration and recharge/discharge classification was found. The radon concentration was also measured at different depths in the soil profile at three locations in the Forsmark area. The results showed large differences with increasing radon concentration with increasing depth. This gradient of radon concentration can be explained largely by the radon emanation potential of the local soil type at different depths. High radon concentrations were found in wells with higher radon emanation potential like till and bedrock. These observations showed the importance of the radon emanation potential of the local soil for the radon concentration in groundwater. The main purpose of this study has been to evaluate the use of radon as a tracer for groundwater flow patterns. The method is based on the ingrowth of radon from its progenitor radium according to the law of radioactive decay. According to this law the radon concentration in groundwater will reach equilibrium conditions after approximately 30 days in contact with the surrounding soil. The equilibrium radon concentration of the near surface groundwater was measured at several location in the Forsmark area and a range of the steady state radon concentration was calculated. The measured steady state radon concentration was then used to evaluate the radon concentrations measured in near surface groundwater in the area. A recharge/discharge classification of the wells was done based on the range of steady state radon concentration and the measured radon concentrations in groundwater. All wells with radon concentration below the steady state radon concentration were

  2. Natural-basement ventilation as a radon-mitigation technique. Final report Jun 89-Feb 91

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.

    1992-04-01

    The report documents a study of natural basement ventilation in two research houses during both the summer cooling season and the winter heating season. (NOTE: Natural basement ventilation has always been recommended as a way to reduce radon levels in houses. However, its efficacy has never been documented. It has generally been assumed to be a very inefficient mitigation strategy since it was believed that dilution was the mechanism by which radon levels were reduced.) Ventilation rates, environmental and house operating parameters, and radon levels have been monitored; it can be concluded that natural ventilation can reduce radon levels two ways: (1) by simple dilution, and (2) although less obvious, by providing a pressure break that reduces basement depressurization and thus the amount of radon-contaminated soil gas drawn into the house. Thus, basement ventilation can be a much more effective mitigation strategy than was previously believed. It might be especially useful in houses with low radon concentrations (of the order of 10 pCi/L) or those with low levels that cannot be mitigated cost-effectively with conventional technology

  3. Radon Measurements in Egypt using passive etched track detectors. A Review

    Energy Technology Data Exchange (ETDEWEB)

    Gomaa, M A [National Network of Radiation Physics. Atomic Energy Authority (Egypt); Hussein, A S [Radiation Protection Department, Nuclear Power Plants Authority, (Egypt); El-Arabi, A M [Physics Department, Faculty of Science, South Valley University, Qena, (Egypt)

    2005-04-01

    Radon and its progeny may cause serious radiation harm to human health such as lung cancer and other types. Radon measurements based on alpha particles etched track detectors (LR-115, CR-39) are very attractive for assessment of radon exposure. This is due to their high sensitivity, low cost, easy to handle and retain a permanent record of data. Also these detectors can incorporate the effects of seasonal and diurnal fluctuation of radon activity concentrations due to physical, geological and meteorological factors. The present review is based mainly on the topic of passive etched track detectors for the measurements of radon in Egypt in the recent years. Published papers includes the measurements of radon in dwellings, working places, Cairo Metro stations, ancient Pharaonic places and uranium exploration galleries as well as assessment of radon in drinking water.

  4. Radon Measurements in Egypt using passive etched track detectors. A Review

    International Nuclear Information System (INIS)

    Gomaa, M.A.; Hussein, A.S.; El-Arabi, A.M.

    2005-01-01

    Radon and its progeny may cause serious radiation harm to human health such as lung cancer and other types. Radon measurements based on alpha particles etched track detectors (LR-115, CR-39) are very attractive for assessment of radon exposure. This is due to their high sensitivity, low cost, easy to handle and retain a permanent record of data. Also these detectors can incorporate the effects of seasonal and diurnal fluctuation of radon activity concentrations due to physical, geological and meteorological factors. The present review is based mainly on the topic of passive etched track detectors for the measurements of radon in Egypt in the recent years. Published papers includes the measurements of radon in dwellings, working places, Cairo Metro stations, ancient Pharaonic places and uranium exploration galleries as well as assessment of radon in drinking water

  5. Activity measurements of radon from construction materials.

    Science.gov (United States)

    Fior, L; Nicolosi Corrêa, J; Paschuk, S A; Denyak, V V; Schelin, H R; Soreanu Pecequilo, B R; Kappke, J

    2012-07-01

    This work presents the results of radon concentration measurements of construction materials used in the Brazilian industry, such as clay (red) bricks and concrete blocks. The measurements focused on the detection of indoor radon activity during different construction stages and the analysis of radionuclides present in the construction materials. For this purpose, sealed chambers with internal dimensions of approximately 60×60×60 cm3 were built within a protected and isolated laboratory environment, and stable air humidity and temperature levels were maintained. These chambers were also used for radon emanation reduction tests. The chambers were built in four major stages: (1) assembly of the walls using clay (red) bricks, concrete blocks, and mortar; (2) installation of plaster; (3) finishing of wall surface using lime; and (4) insulation of wall surface and finishing using paint. Radon measurements were performed using polycarbonate etched track detectors. By comparing the three layers applied to the masonry walls, it was concluded that only the last step (wall painting using acrylic varnish) reduced the radon emanation, by a factor of approximately 2. Samples of the construction materials (clay bricks and concrete blocks) were ground, homogenized, and subjected to gamma-ray spectrometry analysis to evaluate the activity concentrations of 226Ra, 232Th and 40K. The values for the index of the activity concentration (I), radium equivalent activity (Raeq), and external hazard index (Hext) showed that these construction materials could be used without restrictions or concern about the equivalent dose limit (1 mSv/year). Copyright © 2011 Elsevier Ltd. All rights reserved.

  6. Radon in workplaces

    International Nuclear Information System (INIS)

    Reichelt, A.; Lehmann, K.-H.; Reineking, A.; Porstendoerfer, J.; Schwedt, J.; Streil, T.

    2000-01-01

    The radiological assessment of the results of radon measurements in dwellings is not automatically applicable to workplaces due to different forms of utilization, constructional conditions, time of exposure, heating and ventilation conditions, additional aerosol sources, aerosol parameters, chemical substances, etc. In order to investigate the peculiarities of the radon situation in workplaces located inside buildings compared with that in dwellings, long-time recordings of radon, attached radon progeny and unattached radon progeny concentrations ( 218 Po, 214 Pb, 214 Bi) are carried out at several categories of workplaces (e.g. offices, social establishments, schools, production rooms, workshops, kitchens, agricultural facilities). 36 workplaces have been investigated. There have been carried out at least 2-3 long-time recordings for each workplace during different seasons. At the same time the gamma dose rate, meteorological conditions, aerosol particle concentrations have been registered. Many special dates from the workplaces and the buildings have been recorded. Activity size distribution of the aerosol-attached and unattached fraction of short-lived radon decay products have been determinated in 20 workplaces. Mainly the following measurement systems were used: Radon- and Radon Progeny Monitor EQF 3020, SARAD GmbH, Germany. Alpha-Track Radon Detectors, BfS Berlin, Germany. Screen Diffusion Batteries with Different Screens, University of Goettingen, Germany. Low-Pressure Cascade Impactor, Type BERNER. Condensation Nuclei Counter, General Electric, USA. PAEC-f p -Rn-Monitor, University of Goettingen, Germany. Through the measurements, many peculiarities in the course of the radon-concentration, the equilibrium factor F, the unattached fraction f p and the activity size distribution have been determined. These amounts are influenced mainly by the working conditions and the working intervals. The influence of these peculiarities in workplaces on the dose have

  7. Public perceptions of radon risk

    International Nuclear Information System (INIS)

    Mainous, A.G. III; Hagen, M.D.

    1993-01-01

    Since 1984, a significant amount of media attention has focused on health threats from radon gas exposure. Using a probability telephone survey of adults (n = 685), we studied public perceptions of risk from radon exposure versus other environmental health risks. The results indicated that 92% of those individuals who had heard of radon believe radon to be a health risk, although only 4% believe they are currently exposed to high levels of radon gas. Perception of risk from radon was positively related to other perceptions of environmental risks. Younger and less educated individuals were more likely to perceive radon as a health risk. Women were three-and-one-half times as likely as men to perceive risk from radon. However, there was no significant relationship between perceived risk from radon and cigarette smoking. Media attention has apparently led to public awareness of radon hazards, but further attention is needed to improve smokers' awareness of their special risks from radon

  8. Radon Research Program, FY 1991

    International Nuclear Information System (INIS)

    1992-03-01

    The scientific information being sought in this program encompasses research designed to determine radon availability and transport outdoors, modeling transport into and within buildings, physics and chemistry of radon and radon progeny, dose response relationships, lung cancer risk, and mechanisms of radon carcinogenesis. The main goal of the DOE/OHER Radon Research Program is to develop information to reduce these uncertainties and thereby provide an improved health risk estimate of exposure to radon and its progeny as well as to provide information useful in radon control strategies. Results generated under the Program were highlighted in a National Research Council report on radon dosimetry. The study concluded that the risk of radon exposure is 30% less in homes than in mines. This program summary of book describes the OHER FY-1991 Radon Research Program. It is the fifth in an annual series of program books designed to provide scientific and research information to the public and to other government agencies on the DOE Radon Research Program

  9. Swiss radon programme 'RAPROS'

    International Nuclear Information System (INIS)

    Zeller, W.

    1992-03-01

    The results of the five-year radon research program RAPROS presented in this report, allow for scientifically valid statements on the origin of elevated levels of indoor radon in Switzerland. These results form a basis for recommendations and for actions to be taken. Indoor radon concentrations have been measured in more than 4000 living-rooms and 2000 basements; a sampling density of about 0.2% of the Swiss housing stock. According to these measurements radon leads to an estimated average annual effective dose of 2 milli-Sievert, although in some regions the annual dose may be much higher. Extrapolation of the existing data shows that in about 10'000 Swiss houses radon may exceed 1000 Bq/m 3 . For these houses remedial actions are recommended. There seems to be no radon problem in the large cities in the Swiss Plateau. High indoor radon concentrations in Switzerland are due to the soil beneath the buildings. Data from the study indicated that the most important soil characteristic influencing indoor radon concentrations was its gas permeability. Because natural ventilation in a heated house creates a slight underpressure in the lower levels with respect to surrounding soils, radon is driven from the soil into the building. Weatherization of the houses to reduce energy consumption had in most cases no effect on the indoor radon concentrations. Radon from tap water or from building materials does not contribute significantly to indoor radon levels in Switzerland. The high levels in the Jura Mountains are thought to be associated with karstic limestone bedrock. Several houses within Switzerland have now been modified to reduce radon levels. The most successful mitigation technique combined forced-air ventilation with tightening of the basement to decrease or prevent air infiltration from the soil. (author) figs., tabs., refs

  10. Cost and effectiveness of radon-resistant features in new school buildings

    International Nuclear Information System (INIS)

    Craig, A.B.; Leovic, K.W.; Saum, D.W.

    1991-01-01

    Recent concerns over elevated levels of radon in existing buildings have prompted the design and construction of a number of school buildings that either are radon resistant or incorporate features that facilitate post-construction mitigation if needed. This paper describes initial results of a study of several schools with radon-resistant features that were recently constructed in the northeastern US. These designs are generally based on experience with radon mitigation in existing houses and schools and radon-resistant new house construction. The study was limited to slab-on-grade schools, where the most common radon-resistant school design is active subslab depressurization (ASD). The additional construction costs for eight schools built with ASD ranged from $3 to $11 per square meter of slab area. The radon contractors who designed these systems have tended to overdesign the radon-reduction systems in the absence of specific written guidance to follow to lessen potential liability in the event of system failure. Design features include detailed sealing of all stab cracks, multiple exhaust stacks, and extensive subslab piping. Recent Environmental Protection Agency (EPA) research on radon mitigation suggests that simpler ASD systems may provide sufficient radon resistance in new large buildings at lower costs. Components of a specification for radon-resistant school construction are discussed, based on comments from radon system designers. Another school being studied was built with a heating, ventilating, and air-conditioning (HVAC) pressurization radon control system, and considerations for this type of system are examined

  11. Environmental radon

    International Nuclear Information System (INIS)

    Majumdar, S.K.; Schmalz, R.F.; Miller, E.W.

    1990-01-01

    This book covers many aspects of environmental radon, including: historical perspectives; occurrence and properties; detection, measurement, and mitigation, radon and health; and political, economic, and legislative impacts

  12. Investigation of radon-222 emissions from underground uranium mines. Progress report No. 2

    International Nuclear Information System (INIS)

    Jackson, P.O.; Glissmeyer, J.A.; Enderlin, W.I.; Schwendiman, L.C.; Wogman, N.A.; Perkins, R.W.

    1980-02-01

    A reliable estimate of radon emissions to the environment from underground uranium mines was obtained through measurements of radon in ventilation exhaust air at 24 uranium mines and estimates of radon release from ore piles and waste piles at mines and in water pumped from mines. Three additional mines sampled in 1978 but not in 1979 were included in the overall results. Total production of U 3 O 8 from the mines thus far sampled represent about 63% of total 1978 US production from underground mines. Wide variation in radon emission per unit of production was shown from mine to mine; hence, it became necessary to sum all radon from all mines measured and divide by the sum of all U 3 O 8 production in 1978 from these mines to arrive at a valid estimate of Ci per ton of U 3 O 8 . This value was found to be 26.7 per ton or 5400 Ci/RRY (182 metric tons). The radon emitted in mine ventilation air was by far the dominant source, with other than ventilation exhaust sources accounting for less than three percent of radon in ventilation exhaust. Other observations of interest in this study were the diurnal fluctuations of radon with barometric pressure and the statistically significant relationship between radon released per year from a mine and the cumulative ore production at the time of radon measurement. The linear relationship between Ci/yr of radon and cumulative ore accounted for about half the variability.Several sources of random errors and possible biases were evaluated using some simple descriptive statistics insofar as the current data permitted. Errors in air flow rate in the vents sampled, fluctuations in radon emission with time of day, counting instrument calibration and production rate were estimated and combined to give an uncertainty of about +- 24 percent at the 95 percent confidence level

  13. Indoor radon survey in dwellings of some regions in Yemen

    Energy Technology Data Exchange (ETDEWEB)

    Khayrat, A.H. E-mail: akhayrat@yahoo.com; Al-Jarallah, M.I.; Fazal-ur-Rehman, X.; Abu-Jarad, F

    2003-06-01

    Indoor radon survey in a total of 241 dwellings, distributed in some regions of Yemen was performed, using CR-39 based radon monitors. The objective of this radon survey is to get representative indoor radon data of three regions, namely Dhamar, Taiz and Hodeidah, situated at different altitudes above sea level. The radon concentrations varied from 3 to 270 Bq m{sup -3} with an average of 42 Bq m{sup -3}. It was found that the average radon concentration in the surveyed areas increases with altitudes. The highest average radon concentration of 59 Bq m{sup -3} was found in Dhamar city while the lowest average concentration of 8 Bq m{sup -3} was found in Hodeidah city.

  14. A new instrument for quick determination of radon and radon-daughter concentrations in air. Concept, analytical basis, calibration, caveats, the embodiment and field results

    International Nuclear Information System (INIS)

    Shreve, J.D. Jr.; Miller, R.W.; Cleveland, J.E.

    1977-01-01

    A new technique for measuring the radiation exposure hazard associated with radon daughters has been developed over a three-year period by Kerr McGee Nuclear Corporation. General physical configurations of the instrument were field evaluated and redesigned for maximum utility and user convenience in an underground mining situation. The principle of operation is based on the observation that the sum of ALPHA and BETA activity of a radon daughter sample collected on a particulate filter is a slowly vrying constant over a wide range of air 'age' and radon gas concentrations. The model 811 Instant Working Level Meter can provide a working level readout directly in 3 1/2 minutes after the start of air sampling as opposed to the 30-90 minutes necessary when using the other available techniques. The model 811 weighs 11 pounds, has digital LED readout directly in working level, can be used to estimate gamma exposure, and is operated by Ni Cad rechargeable batteries capable of providing 40 working level determinations in an 8 hour period. The working level measurements can be used together with a nomograph to calculate the approximate 'age of air' and to estimate the concentration of radon gas that produced the sample. A comparison and analysis of results obtained using the 811 and the Kusnetz and Tsivoglou methods both in the field and the laboratory, indicates the Instant Working Level Meter provides comparable data in about one-tenth the time. The economics and capacity for greater protection will be discussed as well as operating mechanics and principles

  15. Radon thematic days - Conference proceedings

    International Nuclear Information System (INIS)

    2011-03-01

    This document brings together the available presentations given at the Radon thematic days organized by the French society of radiation protection (SFRP). Twenty five presentations (slides) are compiled in the document and deal with: 1 - General introduction about radon (Sebastien Baechler, IRA); 2 - Survey of epidemiological studies (Dominique Laurier, IRSN); 3 - Dosimetric model (Eric Blanchardon, Estelle Davesne, IRSN); 4 - Radon issue in Franche-Comte: measurement of the domestic exposure and evaluation of the associated health impact (Francois Clinard, InVS); 5 - WHO's (World Health Organization) viewpoint in limiting radon exposure in homes (Ferid Shannoun, OMS); 6 - Radon measurement techniques (Roselyne Ameon, IRSN); 7 - Quality of radon measurements (Francois Bochud, IRA); 8 - International recommendations (Jean-Francois Lecomte, IRSN); 9 - Radon management strategy in Switzerland - 1994-2014 (Christophe Murith, OFSP); 10 - 2011-2015 action plan for radon risk management (Jean-Luc Godet, Eric Dechaux, ASN); 11 - Radon at work place in Switzerland (Lisa Pedrazzi, SUVA); 12 - Strategies of radiation protection optimization in radon exposure situations (Cynthia Reaud, CEPN); 13 - Mapping of the radon potential of geologic formations in France (Geraldine Ielsch, IRSN); 14 - Radon database in Switzerland (Martha Gruson, OFSP); 15 - Radon 222 in taps water (Jeanne Loyen, IRSN); 16 - Buildings protection methods (Bernard Collignan, CSTB, Roselyne Ameon, IRSN); 17 - Preventive and sanitation measures in Switzerland (Claudio Valsangiacomo, SUPSI); 18 - Training and support approach for building specialists (Joelle Goyette-Pernot, Fribourg engineers and architects' school); 19 - Status of radon bulk activity measurements performed between 2005-2010 in public areas (Cyril Pineau, ASN); 20 - Neuchatel Canton experiments (Didier Racine, SENE); 21 - Montbeliard region experience in the radon risk management (Isabelle Netillard, Pays de Montbeliard Agglomeration); 22

  16. Determination of radon partition coefficients between water and different kinds of NAPLs for use in analysis of residual soil NAPLs

    Energy Technology Data Exchange (ETDEWEB)

    Bonfim, Sarah Andresa; Ferreira, Ângela Fortini Macedo, E-mail: sarah_andresa@hotmail.com [Universidade Federal de Migas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Franklin, Mariza Ramalho; Ferreira, Paulo Roberto Rocha [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Rocha, Zildete, E-mail: zildeter7@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Different studies indicate the applicability of natural radon as a tracer in the determination of contaminated environments by Non-Aqueous Phase Liquids (NAPLs). Such use being due to the non-homogeneous distribution of this element between water, air and NAPL. Thus, it is known that the concentration of radon in a given soil / aquifer and in a given area may indicate that such site is contaminated by NAPL. However, the simple measurement of radon concentration activity allows only a qualitative evaluation of the area contaminated in study. For a quantitative estimate of the NAPL saturation in the pore space, it is necessary to know the radon partition coefficients between the coexisting phases, considering the kind of NAPL present. The present study, the radon partitioning coefficients between air, water and diverse types of NAPL mixtures, such as gasoline, diesel fuel, alcohol, kerosene and olive oil was measured. In a closed system, was applied an analytical method based on the distribution of the radon between the present phases with the use of a system of Flow Injection Analysis (FIA). The measurement of the specific activity of radon was performed by using an AlphaGUARD monitor. It is observed that, in the presence of NAPL, the concentration of radon in water and air is significantly lower than in its absence, indicating a negative correlation and allowing the evaluation of the contamination of the area by NAPL. (author)

  17. Determination of radon partition coefficients between water and different kinds of NAPLs for use in analysis of residual soil NAPLs

    International Nuclear Information System (INIS)

    Bonfim, Sarah Andresa; Ferreira, Ângela Fortini Macedo; Rocha, Zildete

    2017-01-01

    Different studies indicate the applicability of natural radon as a tracer in the determination of contaminated environments by Non-Aqueous Phase Liquids (NAPLs). Such use being due to the non-homogeneous distribution of this element between water, air and NAPL. Thus, it is known that the concentration of radon in a given soil / aquifer and in a given area may indicate that such site is contaminated by NAPL. However, the simple measurement of radon concentration activity allows only a qualitative evaluation of the area contaminated in study. For a quantitative estimate of the NAPL saturation in the pore space, it is necessary to know the radon partition coefficients between the coexisting phases, considering the kind of NAPL present. The present study, the radon partitioning coefficients between air, water and diverse types of NAPL mixtures, such as gasoline, diesel fuel, alcohol, kerosene and olive oil was measured. In a closed system, was applied an analytical method based on the distribution of the radon between the present phases with the use of a system of Flow Injection Analysis (FIA). The measurement of the specific activity of radon was performed by using an AlphaGUARD monitor. It is observed that, in the presence of NAPL, the concentration of radon in water and air is significantly lower than in its absence, indicating a negative correlation and allowing the evaluation of the contamination of the area by NAPL. (author)

  18. A passive integrating charcoal detector for indoor radon survey

    International Nuclear Information System (INIS)

    Lin Lianqing; Ren Tianshan; Li Guiyun

    1986-01-01

    This paper describes the principle, design, calibration and characteristics of a passive integrating charcoal detector for measuring average radon concentration indoors. The uncertainties of the detector are also evaluated. Under conditions of room temperature at 17 deg C and relative humidity at 30%, the minimum limit of detection is 0.16 pCi/1 for 72 hours exposure. Besides higher sensitivity, the other advantages of this detector are passive, simple and less expensive. It requires no power and makes no noise and gives no interference to daily activities of the residents of dwellings being surveyed. Therefore the detector is suitable for a large-scale survey of radon levels indoors

  19. Radon-prone areas in the Lombard plain

    International Nuclear Information System (INIS)

    Sesana, Lucia; Polla, Giancarla; Facchini, Ugo; De Capitani, Luisa

    2005-01-01

    This paper reports the results of indoor radon measurements carried out in the Lombard plain. The aim of this study, which is based on the geological context, was to identify radon high-risk areas. The underlying geology has been established by means of the available stratigraphies giving a schematic representation of the sites in which either occurrence of gravel or silt and clay predominate with depths ranging from 0 to 50 m. Radon measurements were performed in a sample of 411 one-family houses in seven villages located in the southern area of Bergamo and Brescia. The findings indicate that when the substrate is dominated by clay, radon concentration for dwellings on the ground floor are low, whereas a strong predominance of underlying gravel mixed up in sand gives in winter months high radon flux from underground

  20. Radon-prone areas in the Lombard plain

    Energy Technology Data Exchange (ETDEWEB)

    Sesana, Lucia [Istituto di Fisica Generale Applicata, Universita degli Studi di Milano, Via G. Celoria, 16 - 20133 Milan (Italy)]. E-mail: lucia.sesana@unimi.it; Polla, Giancarla [Istituto di Fisica Generale Applicata, Universita degli Studi di Milano, Via G. Celoria, 16 - 20133 Milan (Italy); Facchini, Ugo [Istituto di Fisica Generale Applicata, Universita degli Studi di Milano, Via G. Celoria, 16 - 20133 Milan (Italy); De Capitani, Luisa [Dipartimento di Scienze della Terra, Universita degli Studi di Milano, Via Botticelli, 23 - 20133 Milan (Italy)

    2005-07-01

    This paper reports the results of indoor radon measurements carried out in the Lombard plain. The aim of this study, which is based on the geological context, was to identify radon high-risk areas. The underlying geology has been established by means of the available stratigraphies giving a schematic representation of the sites in which either occurrence of gravel or silt and clay predominate with depths ranging from 0 to 50 m. Radon measurements were performed in a sample of 411 one-family houses in seven villages located in the southern area of Bergamo and Brescia. The findings indicate that when the substrate is dominated by clay, radon concentration for dwellings on the ground floor are low, whereas a strong predominance of underlying gravel mixed up in sand gives in winter months high radon flux from underground.

  1. Health effects of radon in air

    International Nuclear Information System (INIS)

    Cohen, B.L.

    1988-01-01

    Widely accepted risk estimates for exposure to radon in homes are derived largely from studies of miners. These include large groups of US Czechoslovakian, and Canadian uranium miners, Newfoundland fluorspar miners, and Swedish iron, lead, and zinc miners, all of which give roughly consistent results, with the excess risk of lung cancer increasing linearly with the exposure to radon. The authors have studied correlations between average radon levels and lung cancer rates in counties of the US. One study based on 50,000 purchased measurements in the main living areas of houses in which there have been no previous measurements involves 310 counties. It gives a weak but statistically significant negative correlation between mean radon levels and lung cancer rates for both females and males, whereas the usual risk estimates predict a large positive correlation

  2. Validation and application of the methodology for analysis of radon concentration in the air through the technique of solid state nuclear track detectors (SSNTD)

    International Nuclear Information System (INIS)

    Carvalho, Caroline de; Comissao Nacional de Energia Nuclear; Silva, Nivaldo Carlos da

    2011-01-01

    Radon is a radioactive noble gas that occurs naturally in soil and could enter into residential. The decay products of radon are radioactive metals which, when inhaled, can be retained in the respiratory system, leading to an internal dose of radiation. The monitoring of radon levels in residences and workplaces is extremely important, since high concentrations of this gas can cause serious public health problems. This study analyzed the concentration of radon in the air in 94 work environments at the Laboratory of Pocos de Caldas - LAPOC/CNEN, including laboratories, administrative rooms, workshop, warehouse and guardhouse. The method employed in the monitoring was the technique of solid state nuclear track detectors, known as SSNTD. For calibration and validation of this method, controlled experiments were conducted in laboratory with specific instrumentation. The monitoring results indicated that most environments present radon concentrations above 100 Bq m -3 , which is the reference level recommended by the World Health Organization. (author)

  3. Validation and application of the methodology for analysis of radon concentration in the air through the technique of solid state nuclear track detectors (SSNTD)

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Caroline de [Pontificia Universidade Catolica de Minas Gerais (PUC-Pocos), Pocos de Caldas, MG (Brazil); Comissao Nacional de Energia Nuclear (LAPOC/CNEN), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas; Silva, Nivaldo Carlos da, E-mail: ncsilva@cnen.gov.b [Comissao Nacional de Energia Nuclear (LAPOC/CNEN), Pocos de Caldas, MG (Brazil). Lab. de Pocos de Caldas

    2011-07-01

    Radon is a radioactive noble gas that occurs naturally in soil and could enter into residential. The decay products of radon are radioactive metals which, when inhaled, can be retained in the respiratory system, leading to an internal dose of radiation. The monitoring of radon levels in residences and workplaces is extremely important, since high concentrations of this gas can cause serious public health problems. This study analyzed the concentration of radon in the air in 94 work environments at the Laboratory of Pocos de Caldas - LAPOC/CNEN, including laboratories, administrative rooms, workshop, warehouse and guardhouse. The method employed in the monitoring was the technique of solid state nuclear track detectors, known as SSNTD. For calibration and validation of this method, controlled experiments were conducted in laboratory with specific instrumentation. The monitoring results indicated that most environments present radon concentrations above 100 Bq m{sup -3}, which is the reference level recommended by the World Health Organization. (author)

  4. A survey on radon reduction efficiency of zeolite and bentonite in a chamber with artificially elevated radon concentration

    International Nuclear Information System (INIS)

    Mortazavi, S.M.J.

    2007-01-01

    Complete text of publication follows. Objective: Zeolite which is made of a special crystalline structure is a naturally occurring mineral group and can be used in radioactive waste management for site remediation /decontamination. There are a wide variety of naturally occurring and synthetic zeolites, each with a unique structure. The cations in zeolite are highly mobile and can be exchanged for other cationic species. On the other hand, bentonite forms from weathering of volcanic ash. This material may be used as an engineering barrier to enclose nuclear waste. In this study, radon reducing properties of zeolite and bentonite have been investigated. Methods: Using radioactive lantern mantle, a radon prone area with radon levels reaching the EPA's action level (200 Bq/m 3 ) was designed. Two sets of identical chambers (cylindrical chambers, diameter 10 cm, height 16 cm) were used in this study. No zeolite/bentonite was used in the 1 st set of the chambers. A thin layer of either zeolite or bentonite powder was applied to the base of the first set of chambers. An unburned radioactive lantern mantle (activity 800 Bq) was placed in all chambers (both sets) to artificially increase the radon level inside the chamber and simulate the condition of a radon prone area. Radon level monitoring was performed by using a PRASSI portable radon gas survey meter. Results: After placing the cap on its place, the radon levels inside the 1 st set of the chambers were 871.9, 770.3, 769.2 and 635.7 Bq/m 3 after 15, 30, 45 and 60 minutes respectively. Zeolite significantly decreased the radon concentration inside the chambers and radon levels were 367.9, 435.4, 399.0 and 435.4 Bq/m 3 after 15, 30, 45 and 60 minutes. The observed reduction in the radon level was statistically significant. As the radon concentrations in identical chambers with Bentonite were 550.7, 526.5, 536.2 and 479.8 Bq/m 3 after 15, 30, 45 and 60 minutes respectively, it is evident that zeolite is more efficient in

  5. Temperature calibration formula for activated charcoal radon collectors

    International Nuclear Information System (INIS)

    Cooper, Alexandre; Le, Thiem Ngoc; Iimoto, Takeshi; Kosako, Toshiso

    2011-01-01

    Radon adsorption by activated charcoal collectors such as PicoRad radon detectors is known to be largely affected by temperature and relative humidity. Quantitative models are, however, still needed for accurate radon estimation in a variable environment. Here we introduce a temperature calibration formula based on the gas adsorption theory to evaluate the radon concentration in air from the average temperature, collection time, and liquid scintillation count rate. On the basis of calibration experiments done by using the 25 m 3 radon chamber available at the National Institute of Radiological Sciences in Japan, we found that the radon adsorption efficiency may vary up to a factor of two for temperatures typical of indoor conditions. We expect our results to be useful for establishing standardized protocols for optimized radon assessment in dwellings and workplaces. - Research highlights: → The temperature effect on radon adsorption is proportional to αe β/T . → The calibration formula is CF(T,t)=3.1x10 -5 e (2887)/((T+273)) [1-e -0.080t ]. → The radon adsorption efficiency varies up to a factor of two for T = 8.5-31 o C. → The average temperature is suitable for estimating CF(T,t) in a fluctuating environment.

  6. Temperature calibration formula for activated charcoal radon collectors

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Alexandre, E-mail: alexandre.cooper@gmail.co [Graduate School of Engineering, University of Tokyo, 2-11-16 Yayoi, Bunkyo-ku, Tokyo 113-0032 (Japan); Le, Thiem Ngoc [Institute of Nuclear Science and Technology, Vietnam Atomic Energy Commission, 59 Ly Thuong Kiet, Hanoi (Viet Nam); Iimoto, Takeshi; Kosako, Toshiso [Graduate School of Engineering, University of Tokyo, 2-11-16 Yayoi, Bunkyo-ku, Tokyo 113-0032 (Japan)

    2011-01-15

    Radon adsorption by activated charcoal collectors such as PicoRad radon detectors is known to be largely affected by temperature and relative humidity. Quantitative models are, however, still needed for accurate radon estimation in a variable environment. Here we introduce a temperature calibration formula based on the gas adsorption theory to evaluate the radon concentration in air from the average temperature, collection time, and liquid scintillation count rate. On the basis of calibration experiments done by using the 25 m{sup 3} radon chamber available at the National Institute of Radiological Sciences in Japan, we found that the radon adsorption efficiency may vary up to a factor of two for temperatures typical of indoor conditions. We expect our results to be useful for establishing standardized protocols for optimized radon assessment in dwellings and workplaces. - Research highlights: {yields} The temperature effect on radon adsorption is proportional to {alpha}e{sup {beta}/T}. {yields} The calibration formula is CF(T,t)=3.1x10{sup -5}e{sup (2887)/((T+273))} [1-e{sup -0.080t}]. {yields} The radon adsorption efficiency varies up to a factor of two for T = 8.5-31 {sup o}C. {yields} The average temperature is suitable for estimating CF(T,t) in a fluctuating environment.

  7. Radon in buildings

    International Nuclear Information System (INIS)

    Connell, J.J.

    1991-01-01

    This guide is intended to inform designers, householders and other building owners about the radon problem and to help in deciding if there is need to take any action to reduce radon levels in their homes or other buildings.It explains what radon is, how it enters buildings and what effect it may have on health. Reference is made to some of the usual ways of reducing the level of radon and guidance is given on some sources of assistance

  8. Radon and its hazards

    International Nuclear Information System (INIS)

    Chang Guilan

    2002-01-01

    The author describes basic physical and chemical properties of radon and the emanation, introduces methods of radon measurement, expounds the hazards of non-mine radon accumulation to the health of human being and the protection, as well as the history how the human being recognizes the hazards of radon through the specific data and examples, and finally proposes protecting measures to avoid the hazards of radon to the health of human being, and to do ecologic evaluation of environments

  9. Ventilation systems as an effective tool for control of radon daughter concentration in mines

    International Nuclear Information System (INIS)

    Dory, A.B.

    1981-10-01

    Experience in mines shows that a very high concentration of radon daughters builds up in an unventilated dead end heading. Even minimal air movement results in a drastic reduction in radon daughter concentration. Designing the ventilation system to provide an optimized flow of fresh air into the workplace results in acceptable climatic conditions and radon daughter levels. The example of the Director fluorospar mine in Newfoundland is used to illustrate the actual design and operation of a ventilation system that provided effective radon daughter control. It was found at this mine that the age of the air underground should be kept as low as possible; that no areas of the mine should be left unventilated unless they could be kept at negative pressure; that a comparatively simple remote control and monitoring system helped stabilize ventilation and detected upsets; that the ventilation system should operate continuously, even when the mine is shut down for short periods; and that pressurization of the mine seemed to inhibit radon influx

  10. Effects of natural and forced basement ventilation on radon levels in single-family dwellings. Final report, May 90-Aug 91

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.

    1992-06-01

    The report gives, for the first time, results of an extensive study of the effect of ventilation on radon concentrations and radon entry rate in a single-family dwelling. Measurements of radon concentrations, building dynamics, and environmental parameters made in Princeton University research houses over several seasons and under different building operating conditions show the functional dependence of radon entry rate on basement depressurization. The work clarifies the role of natural ventilation in reducing indoor radon concentrations. The work shows conclusively that natural ventilation can decrease radon levels two ways: (1) by simple dilution, and (2) by providing a pressure break (defined as any opening in the building shell that reduces the outdoor/indoor differential pressure). This reduces building depressurization and thus the amount of radon-contaminated soil gas that is drawn into the building

  11. Measurement of unattached radon progeny based in electrostatic deposition method; Medicion de la fraccion no unida a aerosoles de la progenie de {sup 222}Rn mediante un metodo de deposicion electrostatica

    Energy Technology Data Exchange (ETDEWEB)

    Canoba, A C; Lopez, F O

    1999-07-01

    A method for the measurement of unattached radon progeny based on its electrostatic deposition onto wire screens, using only one pump, has been implemented and calibrated. The importance of being able of making use of this method is related with the special radiological significance that has the unattached fraction of the short-lived radon progeny. Because of this, the assessment of exposure could be directly related to dose with far greater accuracy than before. The advantages of this method are its simplicity, even with the tools needed for the sample collection, as well as the measurement instruments used. Also, the suitability of this method is enhanced by the fact that it can effectively be used with a simple measuring procedure such as the Kusnetz method. (author)

  12. Radon reduction

    International Nuclear Information System (INIS)

    Hamilton, M.A.

    1990-01-01

    During a radon gas screening program, elevated levels of radon gas were detected in homes on Mackinac Island, Mich. Six homes on foundations with crawl spaces were selected for a research project aimed at reducing radon gas concentrations, which ranged from 12.9 to 82.3 pCi/l. Using isolation and ventilation techniques, and variations thereof, radon concentrations were reduced to less than 1 pCi/l. This paper reports that these reductions were achieved using 3.5 mil cross laminated or 10 mil high density polyethylene plastic as a barrier without sealing to the foundation or support piers, solid and/or perforated plastic pipe and mechanical fans. Wind turbines were found to be ineffective at reducing concentrations to acceptable levels. Homeowners themselves installed all materials

  13. An electrical circuit model for simulation of indoor radon concentration.

    Science.gov (United States)

    Musavi Nasab, S M; Negarestani, A

    2013-01-01

    In this study, a new model based on electric circuit theory was introduced to simulate the behaviour of indoor radon concentration. In this model, a voltage source simulates radon generation in walls, conductivity simulates migration through walls and voltage across a capacitor simulates radon concentration in a room. This simulation considers migration of radon through walls by diffusion mechanism in one-dimensional geometry. Data reported in a typical Greek house were employed to examine the application of this technique of simulation to the behaviour of radon.

  14. Human perception of radon risk and radon mitigation: Some remarks

    International Nuclear Information System (INIS)

    Neznal, M.; Neznal, M.

    2008-01-01

    The Radon program in the Czech Republic has a relatively long and rich history. Procedures, which enable to evaluate the risk of radon penetration from the ground, to protect new buildings, to find existing buildings with elevated indoor radon levels and to realise remedial measures in such buildings, have been developed, published and tested. In some cases, the whole system may fail due to psychological or sociological reasons. Three types of problems (conflicts) will be presented: human behaviour affecting measurement results, conflict between individual and 'all-society' points of view, interpretation of radon risk itself. (authors)

  15. Radon/radon-daughter measurement methods and instrumentation

    International Nuclear Information System (INIS)

    Rock, R.L.

    1977-01-01

    Radon-daughter measurement equipment and techniques have been continuously improved over the last 25 years. Improvements have been in the areas of accuracy, time and convenience. We now have miniaturized scalers and detectors available for measuring the alpha particle count rates from aerosol samples collected on filter papers. We also have small lightweight efficient pumps for conveniently collecting samples and we have various counting methods which allow us to choose between making very precise measurements or nominal measurements. Radon-daughter measurement methods used in uranium mines and mills are discussed including a personal radon-daughter-exposure integrating device which can be worn by miners

  16. Comparison of techniques active and passive in measurement of radon concentration ("2"2"2Ra) in the air

    International Nuclear Information System (INIS)

    Oliveira, Evaldo Paulo de

    2017-01-01

    The purpose of this work was to perform a study comparing radon concentration measurements between two techniques used to measure radon gas in the air: one using LEXAN polycarbonate plastic detectors and the other the continuous monitor in AlphaGUARD passive mode. The concentrations of radon gas within radon emanation chambers were measured using calibrated / traceable sources generating "2"2"2Rn through "2"2"6Ra. In calibration the 'calibration factor' or 'sensitivity' was determined for the LEXAN plastic detector. The calibration work of the dosimeters was carried out at the Radon Laboratory of the Environmental Analysis Division - DIRAD IRD/CNEN and at the Natural Radioactivity Laboratory (LRN) of the Center for the Development of Nuclear Technology (CDTN/CNEN). The 'calibration factor' or 'sensitivity' was found to be 32.34 (traits.cm"-"2)/(kBq.d.m"-"3). This factor was used to determine the radon concentration measured by the LEXAN plastic detectors. Also in the calibration, the efficiencies for LEXAN (94.1% ± 9.7%) and AlphaGUARD (92.5% ± 7.2%) were determined. The statistical analysis used showed good parity in the results of the measurements. It was concluded that the results were satisfactory and will serve as a good reference for studies related to the radon air meters used in this work. (author)

  17. Measurements of radon in drinking water (Curitiba, PR, Brazil)

    International Nuclear Information System (INIS)

    Correa, Janine Nicolosi; Paschuk, Sergei A.; Schelin, Hugo R.; Barbosa, Laercio; Sadula, Tatyana; Matsuzaki, Cristiana A.

    2009-01-01

    Full text: Among the principle mechanisms that bring the radon inside the dwelling is the exhalation and release from the water. It was evaluated that considering the latest mechanism, the exhalation of radon from the water represents about 89% of the cancer risk and the consumption of water with high concentration of radon is related to about 11% of risk cancer. Radon concentration in water could be subject of different factors such as the geology of the area, bottom sediments and inputs from streams, temperature, atmospheric pressure, etc. It is well known that the solubility of radon in water is about 510 cm 3 kg -1 at 0 deg C and decreases at higher temperatures. The 222 Rn concentration in various types of natural water in different countries usually is about few Bq/L and is the subject of the National legislation as well as International norms and recommendations. For example, the United States Environmental Protection Agency (USEPA) established a limit of 11.1 Bq/L for the radon level in drinking water and this limit is considered as guideline in Canada and many countries of the European Union. Current work presents the results of more than 100 measurements of 222 Rn activity in drinking water collected at artesian bores at Curitiba region during the period of 2008 - 2009. The measurements were performed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology in cooperation with the Nuclear Technology Development Center (CDTN) of Brazilian Nuclear Energy Committee (CNEN). Experimental setup was based on the Professional Radon Monitor (ALPHA GUARD) connected to specific kit of glass vessels Aqua KIT through the air pump. The equipment was adjusted with air flow of 0.5 L/min. The 222 Rn concentration levels were detected and analyzed by the computer using the software DataEXPERT by GENITRON Instruments. Collected average levels of 222 Rn concentration were processed taking into account the volume of water sample and its temperature

  18. Radon level and radon effective dose rate determination in Moroccan dwellings using SSNTDs

    International Nuclear Information System (INIS)

    Oufni, L.; Misdaq, M.A.; Amrane, M.

    2005-01-01

    Inhalation of radon ( 222 Rn) and its daughter product are a major source of natural radiation exposure. The measurement of radon activity in dwelling is assuming ever increasing importance. It is known from recent surveys in many countries that radon and its progeny contribute significantly to total inhalation dose and it is fairly established that radon when inhaled in large quantity causes lung disorder. Keeping this in view, the indoor radon activity level and radon effective dose rate were carried out in the dwellings of Beni-Mellal, Khouribgra and Ben Guerir cities, Morocco, using the solid state nuclear track detectors (SSNTD) technique. Assuming an indoor occupancy factor of 0.8 and 0.4 for the equilibrium factor of radon indoors, we found that the 222 Rn effective dose rate in the studied dwellings ranges from 1.01 to 7.90mSvy -1 . The radon activity in the corresponding dwellings was found to vary from 40 to 532Bqm -3 . The radon activity has not only been found to vary with seasonal changes, but also with the age, the construction mode of houses, the ventilation conditions and with specific sites and geological materials

  19. Radiation exposure and radon levels in some stations of the Syrian gas company

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Shwekani, R.; Jerbi, B.; Awad, I.

    2006-06-01

    In the present study, exposure levels and radon concentrations have been measured in natural gas production lines at the Syrian gas company. The study area includes gas stations for directories of Der Ezzor, Al-Jbessa, Al-Hassaka, and the middle region. The results showed that radiation exposure rates in remote stations and internal stations were within the natural levels except for two main locations, viz reflex pumps and propane production unites; 3 μSvhr -1 was reported. Radon concentration in Syrian natural gas varied between 15.4 Bqm - 3 and 1141 Bqm - 3; coproduced natural gas was found to contain higher concentration that the free natural gas. In addition, radon concentrations were higher in the central processing facilities that the well heads; these high levels are due to pressurizing and concentrating processes that enhance radon gas and its daughters concentrations in these stations. Moreover, a value of 659 Bqm - 3 in Al-Jbessa directorate gas and 225 Bqm - 3 in Al-Hassaka directorate gas were reported. While the concentration was lower in gas producing safur; a value of 80 Bqm - 3 was observed. On the other hand, maximum radon gas concentrations and its daughters in workplace air environment was found to be relatively high in the gas analysis laboratory and they are due to gas release inside the lab during analysis in addition to good separation of these laboratories from the surrounding environment. (author)

  20. Cigarette smoking increases radon working level exposures to all occupants of the smoker's home

    International Nuclear Information System (INIS)

    Johnson, R.H. Jr.; Rosario, A. Jr.

    1990-01-01

    This paper reports that the 1988 National Academy of Sciences report on radon health risks evaluated the combined effects of radon exposures and cigarettes on the lung cancer risk to smokers. This report showed that the risk of lung cancer is about 10 times greater for smokers than for nonsmokers at the same Working Level exposures. In 1986, the Surgeon General reported that 106,000 lung cancer deaths occurred among smokers. Therefore, the health risks of cigarettes alone or in combination with radon exposures are well recognized. What has not been studied is the effect of cigarette smoke on the Working Levels in homes that increases the exposure to radon decay products to all occupants, both smokers and nonsmokers. Preliminary studies in a radon chamber at Radon QC showed that the smoke from a single cigarette increased the Working Levels by a factor of five within four hours. Furthermore, the Working Levels remained at an elevated level for more than 24 hours. The equilibrium ratio of radon decay products to radon gas also went from about 14% up to 71%, with a slow decrease over 24 hours. Similar studies in the homes of a smoker and nonsmoker confirmed the laboratory observations. The studies in homes also showed the effects of thoron decay products

  1. Radon therapy; Radon in der Therapie

    Energy Technology Data Exchange (ETDEWEB)

    Spruck, Kaija [Technische Hochschule Mittelhessen, Giessen (Germany). Inst. fuer Medizinische Physik und Strahlenschutz

    2017-04-01

    Radon therapies are used since more than 100 years in human medicine. Today this method is controversially discussed due to the possible increase of ionizing radiation induced tumor risk. Although the exact mode of biological radiation effect on the cell level is still not known new studies show the efficiency of the radon therapy without side effect for instance for rheumatic/inflammatory or respiratory disorders.

  2. Retrofit and preoccupancy radon mitigation program for homes

    International Nuclear Information System (INIS)

    Ibach, M.T.; Gallagher, J.H. Jr.

    1987-01-01

    A requirement was levied on a Maryland builder by the FHA to demonstrate acceptable radon levels in his homes before they would be approved for loans. This paper describes the use of products shown by appropriate tests to be effective radon barriers to meet this requirement. The sheet goods can be used in exterior and interior applications on foundation walls. The other is applied to the interior floors and/or walls of the basement area. Product installation procedures are straightforward and relatively simple. Problems encountered were routine and concerned primarily the complete sealing of floor and wall penetrations, window openings, sealing the top of the wall under the sill plate, and the location and mounting of permanent fixtures on walls and floors. Also discussed are methods of repairing ruptures of the seal, warranties to protect the homeowner, support systems and costs. Conclusions are that effective reductions in radon levels can be achieved by the application of sealants during the construction of new homes or as a retrofit to existing structures

  3. Radon as a groundwater tracer in Forsmark and Laxemar

    International Nuclear Information System (INIS)

    Grolander, Sara

    2009-10-01

    caused by the homogenous radon concentrations measured in the Laxemar area. The radon concentrations in near surface water measured in Forsmark showed large variability with both low and high radon concentrations. This large variability in radon concentration could not be explained by the flow pattern of the groundwater since no clear correlation between radon concentration and recharge/discharge classification was found. The radon concentration was also measured at different depths in the soil profile at three locations in the Forsmark area. The results showed large differences with increasing radon concentration with increasing depth. This gradient of radon concentration can be explained largely by the radon emanation potential of the local soil type at different depths. High radon concentrations were found in wells with higher radon emanation potential like till and bedrock. These observations showed the importance of the radon emanation potential of the local soil for the radon concentration in groundwater. The main purpose of this study has been to evaluate the use of radon as a tracer for groundwater flow patterns. The method is based on the ingrowth of radon from its progenitor radium according to the law of radioactive decay. According to this law the radon concentration in groundwater will reach equilibrium conditions after approximately 30 days in contact with the surrounding soil. The equilibrium radon concentration of the near surface groundwater was measured at several location in the Forsmark area and a range of the steady state radon concentration was calculated. The measured steady state radon concentration was then used to evaluate the radon concentrations measured in near surface groundwater in the area. A recharge/discharge classification of the wells was done based on the range of steady state radon concentration and the measured radon concentrations in groundwater. All wells with radon concentration below the steady state radon concentration were

  4. Radon atlas of Finland

    International Nuclear Information System (INIS)

    Voutilainen, A.; Maekelaeinen, I.; Pennanen, M.; Reisbacka, H.; Castren, O.

    1997-11-01

    The most efficient means of reducing indoor radon exposure is to locate and mitigate dwellings with radon concentration exceeding the action level of 400 Bq/m 3 and to build new houses so that radon concentrations do not exceed 200 Bq/m 3 . The maps and tables in this report are useful tools for those who plan and decide what kind of radon mitigation measures are needed in municipalities. STUK (The Radiation and Nuclear Safety Authority) has an indoor radon database of 52 000 dwellings, for which the indoor radon concentration and construction details are known. The building site soil type of about 38 000 dwellings is known. This atlas is a summary of all indoor radon measurements made by STUK in lowrise dwellings and in first-floor flats. The results are shown as arithmetic means of 5- or 10-km squares on maps of the provinces. Three radon maps have been made for each province. On one map the data consist of all measurements the position coordinates of which are known. On the two other maps the building sites of houses are classified into permeable and low-permeable soil types. The tables show statistics for all indoor radon measurements by municipality and building site soil type. (orig.)

  5. Residential radon in Finland: sources, variation, modelling and dose comparisons

    Energy Technology Data Exchange (ETDEWEB)

    Arvela, H

    1995-09-01

    The study deals with sources of indoor radon in Finland, seasonal variations in radon concentration, the effect of house construction and ventilation and also with the radiation dose from indoor radon and terrestrial gamma radiation. The results are based on radon measurements in approximately 4000 dwellings and on air exchange measurements in 250 dwellings as well as on model calculations. The results confirm that convective soil air flow is by far the most important source of indoor radon in Finnish low-rise residential housing. (97 refs., 61 figs., 30 tabs.).

  6. Residential radon in Finland: sources, variation, modelling and dose comparisons

    International Nuclear Information System (INIS)

    Arvela, H.

    1995-09-01

    The study deals with sources of indoor radon in Finland, seasonal variations in radon concentration, the effect of house construction and ventilation and also with the radiation dose from indoor radon and terrestrial gamma radiation. The results are based on radon measurements in approximately 4000 dwellings and on air exchange measurements in 250 dwellings as well as on model calculations. The results confirm that convective soil air flow is by far the most important source of indoor radon in Finnish low-rise residential housing. (97 refs., 61 figs., 30 tabs.)

  7. Plate-out rates of radon progeny and particles in a spherical chamber

    International Nuclear Information System (INIS)

    Cheng, Y.S.; Chen, B.T.

    1990-01-01

    In indoor and mining environments, deposition or ''plate-out'' of radon progeny onto walls occurs simultaneously with attachment of the radon progeny to airborne particles. Attachment and plate-out processes affect the atmosphere in which radon exposures takes place by reducing concentrations and shifting activity size distributions. Both processes have important consequences in determining the deposition pattern and initial dose of inhaled radon progeny. Theoretical deposition models show that turbulence and natural convection in a room are the major factors that influence plate-out rates. Here we describe plate-out measurements for radon progeny and aerosol particles in a spherical chamber under controlled laboratory conditions. The temperature and velocity profiles in still and turbulent air were monitored. A 161-liter spherical aluminum chamber was used to study the mixing. During mixing, air velocity was detected when rotational speeds were higher than 500 rpm. Monodisperse silver aerosols and polystyrene latex particles in the size range of 5 nm to 2 μm were used in the deposition study. Radon-220 progeny were generated by passing Rn-220 gas into the chamber and letting the gas decay into 212 Pb. The deposition rates of the particles and radon progeny ( 212 Pb) in the chamber were determined by monitoring the concentration decay of the aerosol as a function of time

  8. Radon prevention in the design and construction of schools and other large buildings

    International Nuclear Information System (INIS)

    Leovic, K.W.; Craig, A.B.; Harris, D.B.

    1991-01-01

    The paper discusses radon prevention in the design and construction of schools and other large buildings. The U.S. EPA's Office of Research and Development (ORD) has started incorporating radon control measures into the design and construction of new schools and other large buildings. The goal of the new designs is twofold: (1) to prevent elevated radon levels in the completed building, and (2) to provide the protection at a fraction of the cost of retrofit systems. ORD's Air and Energy Engineering Research Laboratory (AEERL) has conducted the research necessary to develop viable designs. The Indoor Radon Abatement Act of 1988 set a national long-term goal for indoor radon of 0.5 picocurie per liter (pCi/L)--the same as that typically found in outdoor air. The EPA currently recommends that homeowners take action to reduce radon levels to below 4 pCi/L. To achieve the national goal set in the 1988 Act for new construction in radon-prone areas, AEERL research is using a combination of active subslab depressurization (ASD) and operation of the heating, ventilation, and air-conditioning (HVAC) system to pressurize buildings. These measures are described briefly, along with a case history of one building

  9. Radon remedial measures in cold climate

    International Nuclear Information System (INIS)

    Birovljev, A.

    2004-01-01

    A view is taken that mitigation of an indoor radon problem is often more complex than usually assumed, and that additional factors should be considered to avoid situations in which after mitigation the radon problem may be solved, but other problems have been created. Emphasis is put on how the choice and design of radon remedial measures are influenced not only by effectiveness in reducing radon levels indoors, but also by climatic factors, energy-saving aspects, as well as economic and psycho-social factors. Climatic conditions give rise to several concerns when attempting to mitigate a radon problem in areas with large seasonal temperature variations. Problems with humidity, energy consumption and durability of sealing materials are probably the most prominent issues. Commonly used radon remedial measures and their effectiveness in Norway is reviewed. Discussion is focused on principles and technical solutions which produce good results, and those which don't perform so well in cold Norwegian climate. Innovative technical solutions which successfully resolve some of the main conflicting issues are discussed. Results of some preliminary tests showing performance of such solutions in reduction of radon levels are presented. Other aspects of mitigation systems, such as need and cost of maintenance, longevity, noise levels, 'additional benefits', etc., are briefly mentioned. Homeowners' perceptions and willingness to implement various mitigation solutions are briefly reviewed. Based on discussion, several guiding principles which may be adopted in search for optimal solutions are suggested. (author)

  10. Scopingreport radon

    International Nuclear Information System (INIS)

    Blaauboer, R.O.; Vaas, L.H.; Hesse, J.M.; Slooff, W.

    1989-09-01

    This report contains general information on radon concerning the existing standards, sources and emissions, the exposure levels and effect levels. lt serves as a basis for the discussion during the exploratory melting to be held in November/December 1989, aimed at determining the contents of the Integrated Criteria Document Radon. Attention is focussd on Rn-222 (radon) and Rn-220 (thoron), presently of public interest because of radon gas pollution in private homes. In the Netherlands air quality standards nor product standards for the exhalation rate of building materials have been recommended. The major source of radon in the Netherlands is the soil gas (> 97%), minor sources are phosphate residues and building materials (> 2% in total). Hence, the major concern is the transfer through the inhalation of air, the lung being the most critical organ at risk to develop cancer. Compared to risks for humans, the risks of radon and its daughters for aquatic and terrestric organisms, as well as for agricultural crops and livestock, are assumed to be limited. In the Netherlands the average dose for man due to radon and thoron progeny is appr. 1.2 mSv per year, the estimated dose range being 0.1-3.5 mSv per year. This dose contributes for about 50% to rhe total exposure due to all sources of ionizing radiation. Of this dose respectively 80% is caused by radon and about 90% is received indoor. The estimated dose for the general population corresponds to a risk for inducing fatal cancers of about 15 x 10-6 per year, ranging from 1.2 x 10-6 to 44 x 10-6 which exceeds the risk limit of 1 x 10-6 per year -as defined in the standardization policy in the Netherlands for a single source of ionizing radiation-with a factor 15 (1- 44). Reduction of exposure is only possible in the indoor environment. Several techniques have been described to reduce the indoor dose, resulting from exhalation of the soil and building materials. )aut- hor). 37 refs.; 3 figs.; 8 tabs

  11. Expert systems: A new approach to radon mitigation training and quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Brambley, M.R.; Hanlon, R.L.; Parker, G.B.

    1990-07-01

    Training radon mitigators and ensuring that they provide high-quality work on the scale necessary to reduce radon to acceptable levels in the large number of homes and schools requiring some mitigation is a challenging problem. The US Environmental Protection Agency and several states have made commendable efforts to train mitigators and ensure that they provide quality services to the public. Expert systems could be used to extend and improve the effectiveness of these efforts. The purpose of this paper is to introduce the radon community to this promising new technology. The paper includes a description of a prototype system developed by Pacific Northwest Laboratory that illustrates several of the capabilities that expert systems can provide, a brief explanation of how the prototype works, and a discussion of the potential roles and benefits of fully-developed expert systems for radon mitigation. 4 refs., 3 figs.

  12. Expert systems: A new approach to radon mitigation training and quality assurance

    International Nuclear Information System (INIS)

    Brambley, M.R.; Hanlon, R.L.; Parker, G.B.

    1990-07-01

    Training radon mitigators and ensuring that they provide high-quality work on the scale necessary to reduce radon to acceptable levels in the large number of homes and schools requiring some mitigation is a challenging problem. The US Environmental Protection Agency and several states have made commendable efforts to train mitigators and ensure that they provide quality services to the public. Expert systems could be used to extend and improve the effectiveness of these efforts. The purpose of this paper is to introduce the radon community to this promising new technology. The paper includes a description of a prototype system developed by Pacific Northwest Laboratory that illustrates several of the capabilities that expert systems can provide, a brief explanation of how the prototype works, and a discussion of the potential roles and benefits of fully-developed expert systems for radon mitigation. 4 refs., 3 figs

  13. Effect of radon transport in groundwater upon gamma-ray borehole logs

    International Nuclear Information System (INIS)

    Nelson, P.H.; Rachiele, R.; Smith, A.

    1980-09-01

    Granitic rock at an experimental waste storage site at Stripa, Sweden, is unusually high in natural radioelements (40 ppM uranium) with higher concentrations occurring locally in thin chloritic zones and fractures. Groundwater seeping through fractures into open boreholes is consequently highly anomalous in its radon content, with activity as high as one microcurie per liter. When total count gamma-ray logs are run in boreholes where groundwater inflow is appreciable, the result is quite unusual: the radon daughter activity in the water adds considerably to the contribution from the rock, and in fact often dominates the log response. The total gamma activity increases where radon-charged groundwater enters a borehole, and remains at a high level as the water flows along the hole in response to the hydraulic gradient. As a consequence, the gamma log serves as a flow profile, locating zones of water entry (or loss) by an increase (or decrease) in the total gamma activity. A simple model has been developed for flow through a thin crack emanating radon at a rate E showing that the radon concentration of water entering a hole is E/Λh, where Λ is the radon decay rate and h the crack aperture, assuming that the flow rate and crack source area are such that an element of water resides within the source area for several radon half-lives or more. Concentration measurements can provide a measurement of the inflow rate. Data from the 127-mm holes in the time-scale drift behave in this fashion

  14. The effect of natural ventilation on radon and radon progeny levels in houses

    International Nuclear Information System (INIS)

    Cavallo, A.; Gadsby, K.; Reddy, T.A.; Socolow, R.

    1992-01-01

    In contradiction to the widely held assumption that ventilation is ineffective as a means of reducing indoor radon concentrations, experiments in a research house have shown that the basement radon level can be reduced by a factor of 5-10 using only natural ventilation. Measurements of the outdoor-basement pressure differential and the radon entry rate show that this unexpectedly large reduction in indoor radon levels is caused by two complementary physical processes. The first mechanism is the obvious one: dilution. Radon concentrations are lowered by the addition of uncontaminated outdoor air. The second mechanism is less evident: an open basement window reduces basement depressurisation. This decreases the rate at which radon-laden soil gas is drawn into the house. It was also found that the radon entry rate is a linear function of basement depressurisation up to a differential pressure of about 4 Pa, as would be expected for laminar soil gas flow; opening two basement windows approximately doubles the building air exchange rate and reduces the radon entry rate by up to a factor of 5. (author)

  15. The history, development and the present status of the radon measurement programme in the United States of America

    International Nuclear Information System (INIS)

    George, A.C.

    2015-01-01

    The US radon measurement programme began in the late 1950's by the US Public Health Service in Colorado, New Mexico and Utah during the uranium frenzy. After the 1967 Congressional Hearings on the working conditions in uranium mines, the US Atomic Energy Commission (AEC) was asked to conduct studies in active uranium mines to assess the exposure of the miners on the Colorado Plateau and in New Mexico. From 1967 to 1972, the Health and Safety Laboratory of the US AEC in New York investigated more than 20 uranium mines for radon and radon decay product concentrations and particle size in 4 large uranium mines in New Mexico. In 1970, the US Environmental Protection Agency (EPA) was established and took over some of the AEC radon measurement activities. Between 1975 and 1978, the Environmental Measurements Laboratory of the US Department of Energy conducted the first detailed indoor radon survey in the USA. Later in 1984, the very high concentrations of radon found in Pennsylvania homes set the wheels in motion and gave birth to the US Radon Industry. The US EPA expanded its involvement in radon issues and assumed an active role by establishing the National Radon Proficiency Program to evaluate the effectiveness of radon measurement and mitigation methods. In 1998, due to limited resources EPA privatised the radon programme. This paper presents a personal perspective of past events and current status of the US radon programme. It will present an update on radon health effects, the incidence rate of lung cancer in the USA and the number of radon measurements made from 1988 to 2013 using short-term test methods. More than 23 million measurements were made in the last 25 y and as a result more than 1.24 million homes were mitigated successfully. It is estimated that <2 % of the radon measurements performed in the USA are made using long-term testing devices. The number of homes above the US action level of 148 Bq m -3 (4 pCi l -1 ) may be ∼8.5 million because ∼50

  16. Risk assessment of radon in the South Dayi District of the Volta Region, Ghana

    Directory of Open Access Journals (Sweden)

    Charles Y. Ansre

    2018-01-01

    Full Text Available Radon is a globally present and known radioactive gas with its ability to cause lung cancer as its major health implication. Ghana currently lacks national policies on radon gas and substantive radon vulnerability map largely due to lack of adequate baseline radon concentration data for the entire country. LR115 type II detectors were deployed in 30 sites/homes within the South-Dayi District. The detectors were retrieved after specified periods and analyzed for the radon concentration at the Nuclear Track Detection Laboratory of the Ghana Atomic Energy Commission. From the results, indoor radon concentration was found to range from 11.60 to 111.07 Bq/m3 with the mean value for the district being 34.90 ± 20.18 Bq/m3, a value lower than the mean global indoor concentration of 40 Bq/m3. The values of 0.44 mS/yr, 8.80 mSv/yr and 1.01 mSv/yr were the mean annual; absorbed dose, equivalent dose and effective dose to lungs respectively for the populace of the district. The mean soil radon concentration for the district was 1.76 ± 0.91 kBq/m3 with values ranging from 0.38 to 3.93 kBq/m3. Correlation and T-test analysis was performed to establish strength of the linear relationship between indoor radon concentration and the soil radon concentration, indoor radon concentration on altitude and soil radon concentration on altitude.

  17. Development of Radon-222 as Natural Tracer for Monitoring the Remediation of NAPL in the Subsurface

    International Nuclear Information System (INIS)

    Davis, Brian M.; Semprini, Lewis; Istok, Jonathan

    2003-01-01

    Naturally occurring 222-radon in ground water can potentially be used as an in situ partitioning tracer to characterize dense nonaqueous phase liquid (DNAPL) saturations. The static method involves comparing radon concentrations in water samples from DNAPL-contaminated and non-contaminated portions of an aquifer. During a push-pull test, a known volume of test solution (radon-free water containing a conservation tracer) is first injected (''pushed'') into a well; flow is then reversed and the test solution/groundwater mixture is extracted (''pulled'') from the same well. In the presence of NAPL radon transport is retarded relative to the conservative tracer. Assuming linear equilibrium partitioning, retardation factors for radon can be used to estimate NAPL saturations.The utility of this methodology was evaluated in laboratory and field settings

  18. Radon og boligen

    DEFF Research Database (Denmark)

    Rasmussen, Torben Valdbjørn

    Radon er en radioaktiv og sundhedsskadelig luftart, som ved indånding øger risikoen for lungekræft. Der er ingen dokumenteret nedre grænse for, hvornår radon er ufarligt. Derfor anbefales det, at man tilstræber et så lavt radonindhold i indeluften som muligt. Man kan hverken lugte, se, høre eller...... smage radon, så vil du vide, om du har radon i din bolig, må du måle radonindholdet i indeluften. Radon forekommer naturligt i jorden og kan suges ind sammen med jordluft, hvis der inde er et undertryk, og hvis konstruktionerne mod jord er utætte. Jordluft trænger ind gennem revner og utætte samlinger......, fx omkring rør til kloak, vand og varmeforsyning. Koncentrationen af radon i jorden varierer meget fra sted til sted, også lokalt og gennem året. Tidligere undersøgelser har vist, at der kan forekomme høje koncentrationer i Sydgrønland, specielt i området syd for Narsalik ved Paamiut, 61°30’N....

  19. Counting radon tracks in Makrofol detectors with the 'image reduction and analysis facility' (IRAF) software package

    International Nuclear Information System (INIS)

    Hernandez, F.; Gonzalez-Manrique, S.; Karlsson, L.; Hernandez-Armas, J.; Aparicio, A.

    2007-01-01

    Makrofol detectors are commonly used for long-term radon ( 222 Rn) measurements in houses, schools and workplaces. The use of this type of passive detectors for the determination of radon concentrations requires the counting of the nuclear tracks produced by alpha particles on the detecting material. The 'image reduction and analysis facility' (IRAF) software package is a piece of software commonly used in astronomical applications. It allows detailed counting and mapping of sky sections where stars are grouped very closely, even forming clusters. In order to count the nuclear tracks in our Makrofol radon detectors, we have developed an inter-disciplinary application that takes advantage of the similitude that exist between counting stars in a dark sky and tracks in a track-etch detector. Thus, a low cost semi-automatic system has been set up in our laboratory which utilises a commercially available desktop scanner and the IRAF software package. A detailed description of the proposed semi-automatic method and its performance, in comparison to ocular counting, is described in detail here. In addition, the calibration factor for this procedure, 2.97+/-0.07kBqm -3 htrack -1 cm 2 , has been calculated based on the results obtained from exposing 46 detectors to certified radon concentrations. Furthermore, the results of a preliminary radon survey carried out in 62 schools in Tenerife island (Spain), using Makrofol detectors, counted with the mentioned procedure, are briefly presented. The results reported here indicate that the developed procedure permits a fast, accurate and unbiased determination of the radon tracks in a large number of detectors. The measurements carried out in the schools showed that the radon concentrations in at least 12 schools were above 200Bqm -3 and, in two of them, above 400Bqm -3 . Further studies should be performed at those schools following the European Union recommendations about radon concentrations in buildings

  20. Nuclear tracks in solids and gas radon measurements

    International Nuclear Information System (INIS)

    Espinosa, G.

    2007-01-01

    Full text: The Department of Energy (DOE), the Environmental Protection Agency (EPA) in USA, and the European Community, have dedicated significant budget to the Radon study, its health effects and remedial actions for controlling and achieving lower levels, in these cases, nationwide research programs have been organized. With the aim to contribute on the radon levels knowledge in our country, the Applied Dosimetry Project at the Physics Institute of the University of Mexico has developed an indoor and outdoor radon measurement methodology. In this paper a passive radon detector device based on CR-39 polycarbonate for use in radon research and routine measurements is presented. As well the methodology for the track formation, automatic reading system, calibration procedure and measurements in a different location, are shown in this work. The results had been compared with dynamic detection systems, and another methodologies and research groups in order to have a high confidence in the radon levels reported. (Author)

  1. Geological Structure and Radon Hazards in Lublin Region

    Directory of Open Access Journals (Sweden)

    Lucjan Gazda

    2018-03-01

    Full Text Available The purpose of the study was to show the relationship between the geological structure of the Lublin region (eastern Poland and radon concentrations in the ground air, and therefore, in the indoor environment of buildings located in that area. The study was based on the information pertaining to the geological structure of Lublin region available in the literature. The radon concentrations in buildings, caves, wells, as well as coal, phosphate and chalk mines were measured with both passive and active methods. Elemental analyses and uranium and lead isotope analyses of ground rocks were also performed. The conducted studies indicated that the sources of radon in Lublin region constitute Paleogene and Mesozoic sedimentary rocks rich in radionuclides. Application of radon remediation methods is recommended in the existing buildings located in the vicinity of these rocks, which are characterized by relatively high radon exhalations. On the other hand, the designed buildings should employ the measures protecting against harmful effects of radon presence.

  2. Radon campaigns. Status report 2008

    International Nuclear Information System (INIS)

    Arvela, H.; Valmari, T.; Reisbacka, H.; Niemelae, H.; Oinas, T.; Maekelaeinen, I.; Laitinen-Sorvari, R.

    2008-12-01

    Radon campaigns aim at activating citizens to make indoor radon measurements and remediation as well as increasing the common awareness of indoor radon questions. Indoor radon increases the risk of lung cancer. Through radon campaigns Radiation and Nuclear Safety Authority (STUK) also promotes the attainment of those goals that the Ministry of Social Affairs and Health has set for municipal authorities in Finland for prevention of the harmful effects of radon. The Ministry of Social Affairs and Health supports this campaign. Radon campaigns were started in autumn 2003. By autumn 2008 the campaigns have been organised already in 64 regions altogether in 160 municipalities. In some municipalities they have already arranged two campaigns. Altogether 14 100 houses have been measured and in 2 100 of these the action limit of radon remediation 400 Bq / m 3 has been exceeded. When participating in radon campaigns the house owners receive a special offer on radon detectors with a reduced price. In 2008 a new practice was introduced where the campaign advertisements were distributed by mail to low-rise residential houses in a certain region. The advertisement includes an order / deposit slip with postage paid that the house owner can send directly to STUK to easily make an order for radon measurement. In the previous radon campaigns in 2003 - 2007 the municipal authorities collected the orders from house owners and distributed later the radon detectors. The radon concentrations measured in the campaign regions have exceeded the action limit of 400 Bq / m 3 in 0 - 39% of houses, depending on the region. The total of 15% of all measurements made exceeded this limit. The remediation activities have been followed by sending a special questionnaire on remedies performed to the house owners. In 2006 - 2007 a questionnaire was sent to those households where the radon concentration of 400 Bq / m 3 was exceeded during the two first campaign seasons. Among the households that replied

  3. Radon and its daughters in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Rundo, J

    1984-05-01

    Prolonged exposure to radon should build up a reservoir of radon in body fat and fluids. Movement of the subject to an environment with a lower radon concentration from an environment with a higher level of radon would result in an exhalation of radon, and the initial exhalation rate of radon should depend on the radon concentration inhaled. This paper describes the behavior of radon and its daughters in vivo and a relationship between the radon exhalation rate and the time after a meal. A major but short-lived postprandial increase in the exhalation rate of radon was observed. We report a similar effect in the exhalation rate of radon by persons containing no radium. It should be noted that the possibility exists that a large amount of radon daughters in the chest may interfere in the investigation of possible internal contamination with plutonium or other actinides by external counting. (author).

  4. Radon in balneology - measurement of radon retention by patients and radiation protection for personell

    International Nuclear Information System (INIS)

    Just, G.; Falkenbach, A.; Grunewald, W.A.; Philipsborn, H. von

    2001-01-01

    In radon balneology patients are exposed to radon either from water or air through the skin or through inhalation. Drinking radon water was not included in the study. Previously, the radon transfer has been determined for an estimate of the medically active amount of radon retained in the patient. A simpler approach of measuring radon in expiration under and after exposure has now been standardised and applied to probands under different conditions of exposure. In addition, radon decay products were measured in sweat, saliva and in the skin. Experimental parameters were evaluated for a comparison of different concentrations observed under different conditions. Results are likely to improve both therapy for patients and radiation protection for members of the personnel. (orig.) [de

  5. Ozone and radon at Cape Grim: A study of their interdependence

    International Nuclear Information System (INIS)

    Zahorowski, W.; Galbally, I.E.; Meyer, C.P.

    1996-01-01

    A discussion of the ozone and radon variations at Cape Grim, Tasmania, and their interdependence is presented. The use of radon concentration as a criterion for baseline conditions ( - 3) results in a baseline data set that has a smaller range of concentrations within each month than that obtained using wind speed and direction as baseline criteria. The passage of cold fronts at Cape Grim is associated with a change in air flow from the continent to the Southern Ocean. Comparison of radon, wind direction and ozone during these events indicates that continental air continues arriving at Cape Grim for several hours after passage of the front and the establishment of the air flow from the baseline sector. This confirms that use of the speed and direction is not necessarily a good method of defining baseline conditions for ozone. When air comes to Cape Grim form over the Tasmanian land surface during those times of the year when (due to solar radiation and temperature) the probability of ozone production is low, the ozone and radon concentrations observed are negatively correlated. A simple model of ozone destruction at the Earth's surface and radon emission from the surface quantitatively describes these observations. (author). 1 tab., 5 figs., 6 refs

  6. A self-calibrating radon monitor with statistical discrimination

    International Nuclear Information System (INIS)

    Valcov, N.; Purghel, L.

    2002-01-01

    A radon monitor, able to perform the measurement of the radon and its progeny volumic activity, in a gamma-ray or natural radiation background field, was developed. The instrument consists of a 10 l ionization chamber, a high voltage source, an integrating preamplifier, a data acquisition system and a personal computer. A new method for self-calibration of Radon volumic activity measurements, based on the alpha counting with an ionization chamber is also presented

  7. Improved predictive mapping of indoor radon concentrations using ensemble regression trees based on automatic clustering of geological units

    International Nuclear Information System (INIS)

    Kropat, Georg; Bochud, Francois; Jaboyedoff, Michel; Laedermann, Jean-Pascal; Murith, Christophe; Palacios, Martha; Baechler, Sébastien

    2015-01-01

    Purpose: According to estimations around 230 people die as a result of radon exposure in Switzerland. This public health concern makes reliable indoor radon prediction and mapping methods necessary in order to improve risk communication to the public. The aim of this study was to develop an automated method to classify lithological units according to their radon characteristics and to develop mapping and predictive tools in order to improve local radon prediction. Method: About 240 000 indoor radon concentration (IRC) measurements in about 150 000 buildings were available for our analysis. The automated classification of lithological units was based on k-medoids clustering via pair-wise Kolmogorov distances between IRC distributions of lithological units. For IRC mapping and prediction we used random forests and Bayesian additive regression trees (BART). Results: The automated classification groups lithological units well in terms of their IRC characteristics. Especially the IRC differences in metamorphic rocks like gneiss are well revealed by this method. The maps produced by random forests soundly represent the regional difference of IRCs in Switzerland and improve the spatial detail compared to existing approaches. We could explain 33% of the variations in IRC data with random forests. Additionally, the influence of a variable evaluated by random forests shows that building characteristics are less important predictors for IRCs than spatial/geological influences. BART could explain 29% of IRC variability and produced maps that indicate the prediction uncertainty. Conclusion: Ensemble regression trees are a powerful tool to model and understand the multidimensional influences on IRCs. Automatic clustering of lithological units complements this method by facilitating the interpretation of radon properties of rock types. This study provides an important element for radon risk communication. Future approaches should consider taking into account further variables

  8. Radon risk mapping of the Czech Republic on a scale 1:50000

    International Nuclear Information System (INIS)

    Barnet, I.; Miksova, J.; Tomas, R.; Karenova, J.

    2000-01-01

    A new type of radon risk maps on a scale 1:50000 was published in the Czech Republic. Maps are based on the vectorized contours of' geological units and rock types and field soil gas radon measurements from the radon database. Radon risk is expressed in four categories. More detailed topography enables to predict the radon risk from bedrock in the intravilans of villages and towns. (author)

  9. Monitoring of the Syrian rift valley using radon technique

    International Nuclear Information System (INIS)

    Al-Hilal, M.; Al-Ali, A.; Jubeli, Y.

    1997-02-01

    Groundwater radon data were recorded once every two months from six monitoring sites of the Syrian rift valley during the year 1996. Radon samples were measured from deep artesian wells and from continuously-flowing springs that are distributed along this most active seismic zone in Syria. The available data were integrated with previously measured groundwater radon data from the same stations in order to estimate the range of normal radon fluctuations in the region. The estimation of such range may enable the separation between usual groundwater radon variations from other outliers which may indicate possible tectonic activities or earthquake hazards in the study area. Periodical radon measurements based on two months intervals and long distance between sampling stations does not enable us to trust with high level of confidence the connection between radon values and any possible earth dynamics. Therefore, shorter measuring time with closer monitoring sites are highly recommended to achieve the optimum advantage of such application. (Author). 8 Figs., 2 Tabs., 10 Refs

  10. Indoor radon measurements and methodologies in Latin American countries

    International Nuclear Information System (INIS)

    Canoba, A.; Lopez, F.O.; Arnaud, M.I.; Oliveira, A.A.; Neman, R.S.; Hadler, J.C.; Iunes, P.J.; Paulo, S.R.; Osorio, A.M.; Aparecido, R.; Rodriguez, C.; Moreno, V.; Vasquez, R.; Espinosa, G.; Golzarri, J.I.; Martinez, T.; Navarrete, M.; Cabrera, I.; Segovia, N.; Pena, P.; Tamez, E.; Pereyra, P.; Lopez-Herrera, M.E.; Sajo-Bohus, L.

    2001-01-01

    According to the current international guidelines concerning environmental problems, it is necessary to evaluate and to know the indoor radon levels, specially since most of the natural radiation dose to man comes from radon gas and its progeny. Several countries have established National Institutions and National Programs for the study of radon and its connection with lung cancer risk and public health. The aim of this work is to present the indoor radon measurements and the detection methods used for different regions of Latin America (LA) in countries such as Argentina, Brazil, Ecuador, Mexico, Peru and Venezuela. This study shows that the passive radon devices based on alpha particle nuclear track methodology (NTM) is one of the more generalized methods in LA for long term indoor radon measurements, CR-39, LR-115 and Makrofol being the more commonly used detector materials. The participating institutions and the radon level measurements in the different countries are presented in this contribution

  11. Radon Mapping of the Osijek Town

    International Nuclear Information System (INIS)

    Radolic, V.; Faj, Z.; Smit, G.; Culo, D.; Planinic, J.

    1998-01-01

    After ten years investigation of radon seasonal variations at three very different locations, as well as radon concentration measurements in kindergartens and schools, systematical indoor radon measurements were undertaken in dwellings of Osijek. Indoor radon was measured by means of the LR-115 nuclear track detector at 48 town locations that gave the arithmetic mean of 71.6 Bq m -3 , standard deviation of 44.0 Bq m -3 and geometric mean of 60.1 Bq m -3 , for the radon concentration range from 23 to 186 Bq m -3 . The empirical frequency distribution of radon concentrations, with the class width of 20 Bq m -3 , was in accordance with the theoretical log-normal distribution which was shown with χ 2 - test. The radon map pointed out a region of higher radon concentrations (central part of the town) that was ascribed to the geological soil structure. Thus supposition was confirmed by radon measurement in the soil gas using radon emanators with the LR-115 film that showed the positive correlation between radon concentrations in the soil and indoors. Radon measurements in Osijeks primary schools pointed out a school that had the highest radon concentration (300 Bq m -3 ) considering all the former indoor radon measurements. The radon distribution in the school building was investigated afterwards radon mitigation procedures were undertaken. (author)

  12. The effect and the amendment of thermoregulation to the stability of radon concentration in radon chamber

    International Nuclear Information System (INIS)

    Zhang Xiongjie; Wang Renbo; Qu Jinhui; Tang Bin; Zhu Zhifu; Man Zaigang

    2010-01-01

    When the temperature in the airtight radon chamber was adjusted, it would induce the frequent changes of the air pressure in chamber, then the radon concentration in the radon chamber would continuously reduce, which could seriously destroy the stability of the radon concentration in radon chamber. In this paper, on the study of the effect reasons to the stability of radon concentration in airtight radon chamber due to the thermoregulation, a new amendment scheme was put forward, and the solutions of the relevant parameters were discussed. The amendment scheme had been successfully applied to HD-6 radon chamber, and achieved good results. (authors)

  13. Application of a radon model to explain indoor radon levels in a Swedish house

    International Nuclear Information System (INIS)

    Font, LL.; Baixeras, C.; Joensson, G.; Enge, W.; Ghose, R.

    1999-01-01

    Radon entry from soil into indoor air and its accumulation indoors depends on several parameters, the values of which normally depend on the specific characteristics of the site. The effect of a specific parameter is often difficult to explain from the result of indoor radon measurements only. The adaptation of the RAGENA (RAdon Generation, ENtry and Accumulation indoors) model to a Swedish house to characterise indoor radon levels and the relative importance of the different radon sources and entry mechanisms is presented. The building is a single-zone house with a naturally-ventilated crawl space in one part and a concrete floor in another part, leading to different radon levels in the two parts of the building. The soil under the house is moraine, which is relatively permeable to radon gas. The house is naturally-ventilated. The mean indoor radon concentration values measured with nuclear track detectors in the crawl-space and concrete parts of the house are respectively 75±30 and 200±80 Bq m -3 . Results of the model adaptation to the house indicate that soil constitutes the most relevant radon source in both parts of the house. The radon concentration values predicted by the model indoors fall into the same range as the experimental results

  14. CONTRIBUTION OF RADON FLOWS AND RADON SOURCES TO THE RADON CONCENTRATION IN A DWELLING

    NARCIS (Netherlands)

    DEMEIJER, RJ; STOOP, P; PUT, LW

    1992-01-01

    In this paper a model is presented for analysis of the radon concentrations in a compartment in terms of contributions from transport by flows of air between compartments and from radon sources in the compartment. Measurements were made to study the effect of increased natural ventilation of the

  15. Radon in soil variations for Vrancea seismic area

    International Nuclear Information System (INIS)

    Zoran, M.

    2002-01-01

    Earthquakes occur as a result of a build up of pressure between colliding sections of the Earth's crust. These sections, known as continental plates, meet at 'fault lines'. According to classical earthquake theory, small earthquakes should continue to grow into large earthquakes until they spread all along the fault line. Vrancea region is fitted to such a model. The mechanical processes of earthquake preparation are always accompanied by deformations, afterwards complex short- or long term precursory phenomena can appear. Macro-fracturing processes are preceded by micro-fracturing phenomena with a resulting radon and other gas precursors (He, CH 4 , NO) anomalies in soil-gas and groundwater. Studies of geochemical and hydrological anomalies preceding significant earthquakes have been reported from China, Japan, Uzbekistan, Mexico, Italy, India and Germany. However, studies of these pre-seismic phenomena have been controversial for several reasons. Temporal variations of radon in soil or water, can give evidence that the emanation of this gas can be correlated with tectonic disturbances. I used nuclear track detectors LR-115 and CN-85 for radon concentration monitoring in soil at 50 cm depth exposed for a period of 30 days in Vrancioaia test area. Time series radon data in soil-gas during of two years long observation period have established that more than 50% of radon concentration increases were correlated with microseismic events of 2-4 magnitude on Richter scale. A clear positive correlation for radon concentration prior one month of seismic event was associated with a registered event of magnitude 5. In order to differentiate the changes due to tectonic disturbances and that of meteorological parameters, were measured barometric pressure, precipitation and temperature. Negative correlation between radon concentration in soil and meteorological parameters was found. To predict a future earthquake, all precursory phenomena must be investigated. The

  16. Radon and radon daughter monitoring (including thoron daughter monitoring)

    International Nuclear Information System (INIS)

    Leach, V.A.; Grealy, G.; Gan, W.

    1982-01-01

    Radon/radon daughter and thoron daughter measurement techniques are outlined. The necessary precautions and critical assessments of each method are also presented with a view to providing a better understanding of the various measurement methods

  17. Certain problems about radon. Pt.1

    International Nuclear Information System (INIS)

    Wu Huishan

    2005-01-01

    Discussion has been made on certain pointed out problems which presently influence the work and development of radon survey, and certain specific problems have been put forward which should be paid much attention and taken measures. Among the problems, some come from cognition, i.e. two kinds of balance and examination about radon, chief culprit of radon's daughter, multiply control and migration, the significance of radon in the water and soil, important standards for designing and evaluating the sites of construction projects, thoughts on the mechanism of the harm of radon and its daughters, diseases causing of both high and low radon, difficulty of emanation of indoor radon, normal low radon from natural marble; and others must be resolved specifically, i.e. establishment of national radon standards as quickly as possible, improvement of on-the-spot examination technique, national-wide radon survey with multiple disciplines and technology, the research on the mechanism of radon's harm and the establishment national radon study center. (authors)

  18. Radon and its daughters in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Rundo, J

    1984-05-01

    Prolonged exposure to radon should build up a reservoir of radon in body fat and fluids. If the subject moved to an environment with a lower radon concentration from an environment with a higher level of radon, the result would be an exhalation of radon, and the initial exhalation rate of radon should depend of the radon concentration inhaled. This paper describes the behavior of radon and its daughters in vivo and a relationship between the radon exhalation rate and the time after a meal. A major but short-lived postprandial increase in the exhalation rate of radon was observed. The author reports a similar effect in the exhalation rate of radon by persons containing no radium. It should be noted that the possibility exists that a large amount of radon daughters in the chest may interfere in the investigation of possible internal contamination with plutonium or other actinides by external counting. 8 figures.

  19. Measurement of exhalation rate of radon and radon concentration in air using open vial method

    International Nuclear Information System (INIS)

    Horiuchi, Kimiko; Ishii, Tadashi.

    1991-01-01

    It was recognized that more than half of total exposure dose on human subject is caused by radon and its decay products which originate from naturally occurring radioactive substances (1988 UNSCEAR). Since then the exhalation of radon from the ground surface has received increasing attention. The authors have developed a new method for the determination of radon in natural water using toluene extraction of radon and applying a liquid scintillation counter of an integral counting technique which is able to get the absolute counting of radon. During these studies, the authors found out that when a counting vial containing of Liquid scintillator (LS)-toluene solution, without a lid, is exposed to the atmosphere for a while, dissolution of radon clearly occurs due to high solubility of radon into toluene layer. To extend this finding for the determination of radon in the atmosphere, the authors devised a new method to actively collect the atmosphere containing radon in a glass bottle by discharging a definite amount of water in it, which is named as open-vial dynamic method. The radon concentration can be easily calculated after the necessary corrections such as the partition coefficient and others. Applying proposed method to measure the radon exhalation rate from the ground surface and radon concentration in air of the dwelling environment, radioactive mineral spring zone and various geological formation such as granitic or sedimentary rocks. (author)

  20. Theoretical evaluation of indoor radon control using a carbon adsorption system

    International Nuclear Information System (INIS)

    Bocanegra, R.; Hopke, P.K.

    1989-01-01

    The conceptual framework for a carbon-based adsorption system for the control of indoor radon is presented. Based on the adsorptivity of typically available activated carbons, it is shown theoretically that carbon bed adsorbers can be effective in lowering indoor radon levels particularly when the area of radon ingress (the basement) has a relatively low exchange rate with the rest of the house