WorldWideScience

Sample records for simple evaluation method

  1. Simple method for evaluating Goldstone diagrams in an angular momentum coupled representation

    International Nuclear Information System (INIS)

    Kuo, T.T.S.; Shurpin, J.; Tam, K.C.; Osnes, E.; Ellis, P.J.

    1981-01-01

    A simple and convenient method is derived for evaluating linked Goldstone diagrams in an angular momentum coupled representation. Our method is general, and can be used to evaluate any effective interaction and/or effective operator diagrams for both closed-shell nuclei (vacuum to vacuum linked diagrams) and open-shell nuclei (valence linked diagrams). The techniques of decomposing diagrams into ladder diagrams, cutting open internal lines and cutting off one-body insertions are introduced. These enable us to determine angular momentum factors associated with diagrams in the coupled representation directly, without the need for carrying out complicated angular momentum algebra. A summary of diagram rules is given

  2. Development of the simple evaluation method of the soil biomass by the ATP measurement

    Czech Academy of Sciences Publication Activity Database

    Urashima, Y.; Nakajima, M.; Kaneda, Satoshi; Murakami, T.

    2007-01-01

    Roč. 78, č. 2 (2007), s. 187-190 ISSN 0029-0610 Institutional research plan: CEZ:AV0Z60660521 Keywords : simple evaluation method * soil biomass * ATP measurement Subject RIV: EH - Ecology, Behaviour

  3. Simple and efficient methods for the accurate evaluation of patterning effects in ultrafast photonic switches

    DEFF Research Database (Denmark)

    Xu, Jing; Ding, Yunhong; Peucheret, Christophe

    2011-01-01

    Although patterning effects (PEs) are known to be a limiting factor of ultrafast photonic switches based on semiconductor optical amplifiers (SOAs), a simple approach for their evaluation in numerical simulations and experiments is missing. In this work, we experimentally investigate and verify...... as well as the operation bit rate. Furthermore, a simple and effective method for probing the maximum PEs is demonstrated, which may relieve the computational effort or the experimental difficulties associated with the use of long PRBSs for the simulation or characterization of SOA-based switches. Good...... agrement with conventional PRBS characterization is obtained. The method is suitable for quick and systematic estimation and optimization of the switching performance....

  4. A simple gamma spectrometry method for evaluating the burnup of MTR-type HEU fuel elements

    Energy Technology Data Exchange (ETDEWEB)

    Makmal, T. [The Unit of Nuclear Engineering, Ben-Gurion University of The Negev, Beer-Sheva 84105 (Israel); Nuclear Physics and Engineering Division, Soreq Nuclear Research Center, Yavne 81800 (Israel); Aviv, O. [Radiation Safety Division, Soreq Nuclear Research Center, Yavne 81800 (Israel); Gilad, E., E-mail: gilade@bgu.ac.il [The Unit of Nuclear Engineering, Ben-Gurion University of The Negev, Beer-Sheva 84105 (Israel)

    2016-10-21

    A simple method for the evaluation of the burnup of a materials testing reactor (MTR) fuel element by gamma spectrometry is presented. The method was applied to a highly enriched uranium MTR nuclear fuel element that was irradiated in a 5 MW pool-type research reactor for a total period of 34 years. The experimental approach is based on in-situ measurements of the MTR fuel element in the reactor pool by a portable high-purity germanium detector located in a gamma cell. To corroborate the method, analytical calculations (based on the irradiation history of the fuel element) and computer simulations using a dedicated fuel cycle burnup code ORIGEN2 were performed. The burnup of the MTR fuel element was found to be 52.4±8.8%, which is in good agreement with the analytical calculations and the computer simulations. The method presented here is suitable for research reactors with either a regular or an irregular irradiation regime and for reactors with limited infrastructure and/or resources. In addition, its simplicity and the enhanced safety it confers may render this method suitable for IAEA inspectors in fuel element burnup assessments during on-site inspections. - Highlights: • Simple, inexpensive, safe and flexible experimental setup that can be quickly deployed. • Experimental results are thoroughly corroborated against ORIGEN2 burnup code. • Experimental uncertainty of 9% and 5% deviation between measurements and simulations. • Very high burnup MTR fuel element is examined, with 60% depletion of {sup 235}U. • Impact of highly irregular irradiation regime on burnup evaluation is studied.

  5. Evaluation of ductile tearing in a cracked component with a simple method (Js)

    International Nuclear Information System (INIS)

    Moulin, D.; Drubay, B.; Clement, G.; Nedelec, M.

    1995-01-01

    In the nuclear industry, it is more and more usual to perform fracture assessment on detective structures made of ductile material with the help of elastoplastic' fracture mechanics relying on the parameter J. Several engineering methods have been developed in the past to calculate this parameter. These results were used to develop a practical procedure noted Js method which simply gives J as function of elastically calculated Je and a plastic correction factor. This method has been introduced in the A16 rule developed jointly by CEA-EdF and Novatome for fast breeder reactors in particular in order to evaluate the loading at crack instability taking into a account ductile tearing. The determination of initiation has already been presented. This determination of the loading at crack instability is examined through two simple but representative examples using the simplified estimation of J. Predicted loadings at crack instability are compared with experimental results. This study was carried out a part of cooperative program with the Institut de Protection et de Surete Nucleaire of the CEA. (author) 12 refs., 10 figs

  6. A simple red-ox titrimetric method for the evaluation of photo ...

    Indian Academy of Sciences (India)

    Unknown

    tal conditions in a relatively short duration in R&D labora- tories having basic analytical facilities. The method suggested here could also be adopted to study the photo- catalytic activity of other transition metal oxide based catalysts. For establishing this technique, we have moni- tored a simple one-electron transfer red-ox ...

  7. A simple method to evaluate the composition of tissue-equivalent phantom materials

    International Nuclear Information System (INIS)

    Geske, G.

    1977-01-01

    A description is given of a method to calculate the composition of phantom materials with given density and radiation-physical parameters mixed of components, of which are known their chemical composition and their effective specific volumes. By an example of a simple composition with three components the method is illustrated. The results of this example and some experimental details that must be considered are discussed. (orig.) [de

  8. Evaluation of radiation shielding performance in sea transport of radioactive material by using simple calculation method

    International Nuclear Information System (INIS)

    Odano, N.; Ohnishi, S.; Sawamura, H.; Tanaka, Y.; Nishimura, K.

    2004-01-01

    A modified code system based on the point kernel method was developed to use in evaluation of shielding performance for maritime transport of radioactive material. For evaluation of shielding performance accurately in the case of accident, it is required to preciously model the structure of transport casks and shipping vessel, and source term. To achieve accurate modelling of the geometry and source term condition, we aimed to develop the code system by using equivalent information regarding structure and source term used in the Monte Carlo calculation code, MCNP. Therefore, adding an option to use point kernel method to the existing Monte Carlo code, MCNP4C, the code system was developed. To verify the developed code system, dose rate distribution in an exclusive shipping vessel to transport the low level radioactive wastes were calculated by the developed code and the calculated results were compared with measurements and Monte Carlo calculations. It was confirmed that the developed simple calculation method can obtain calculation results very quickly with enough accuracy comparing with the Monte Carlo calculation code MCNP4C

  9. A simple method of dosimetry for E-beam radiation

    International Nuclear Information System (INIS)

    Spencer, D.S.; Thalacker, V.P.; Chasman, J.N.; Siegel, S.

    1985-01-01

    A simple method utilizing a photochromic 'intensity label' for monitoring electron-beam sources was evaluated. The labels exhibit a color change upon exposure to UV or e-beam radiation. A correlation was found between absorbed energy and Gardner Color Index at low electron-beam doses. (author)

  10. Development of a novel and simple method to evaluate disintegration of rapidly disintegrating tablets.

    Science.gov (United States)

    Hoashi, Yohei; Tozuka, Yuichi; Takeuchi, Hirofumi

    2013-01-01

    The purpose of this study was to develop and test a novel and simple method for evaluating the disintegration time of rapidly disintegrating tablets (RDTs) in vitro, since the conventional disintegration test described in the pharmacopoeia produces poor results due to the difference of its environmental conditions from those of an actual oral cavity. Six RDTs prepared in our laboratory and 5 types of commercial RDTs were used as model formulations. Using our original apparatus, a good correlation was observed between in vivo and in vitro disintegration times by adjusting the height from which the solution was dropped to 8 cm and the weight of the load to 10 or 20 g. Properties of RDTs, such as the pattern of their disintegrating process, can be assessed by verifying the load. These findings confirmed that our proposed method for an in vitro disintegration test apparatus is an excellent one for estimating disintegration time and the disintegration profile of RDTs.

  11. Substoichiometric method in the simple radiometric analysis

    International Nuclear Information System (INIS)

    Ikeda, N.; Noguchi, K.

    1979-01-01

    The substoichiometric method is applied to simple radiometric analysis. Two methods - the standard reagent method and the standard sample method - are proposed. The validity of the principle of the methods is verified experimentally in the determination of silver by the precipitation method, or of zinc by the ion-exchange or solvent-extraction method. The proposed methods are simple and rapid compared with the conventional superstoichiometric method. (author)

  12. Simple and fast PO-CL method for the evaluation of antioxidant capacity of hydrophilic and hydrophobic antioxidants

    Science.gov (United States)

    Zargoosh, Kiomars; Ghayeb, Yousef; Azmoon, Behnaz; Qandalee, Mohammad

    2013-08-01

    A simple and fast procedure is described for evaluating the antioxidant activity of hydrophilic and hydrophobic compounds by using the peroxyoxalate-chemiluminescence (PO-CL) reaction of Bis(2,4,6-trichlorophenyl) oxalate (TCPO) with hydrogen peroxide in the presence of di(tert-butyl)2-(tert-butylamino)-5-[(E)-2-phenyl-1-ethenyl]3,4-furandicarboxylate as a highly fluorescent fluorophore. The IC50 values of the well-known antioxidants were calculated and the results were expressed as gallic equivalent antioxidant capacity (GEAC). It was found that the proposed method is free of physical quenching and oxidant interference, for this reason, proposed method is able to determine the accurate scavenging activity of the antioxidants to the free radicals. Finally, the proposed method was applied to the evaluation of antioxidant activity of complex real samples such as soybean oil and sunflower oil (as hydrophobic samples) and honey (as hydrophilic sample). To the best of our knowledge, this is the first time that total antioxidant activity can be determined directly in soybean oil, sunflower oil and honey (not in their extracts) using PO-CL reactions.

  13. Simple-MSSM: a simple and efficient method for simultaneous multi-site saturation mutagenesis.

    Science.gov (United States)

    Cheng, Feng; Xu, Jian-Miao; Xiang, Chao; Liu, Zhi-Qiang; Zhao, Li-Qing; Zheng, Yu-Guo

    2017-04-01

    To develop a practically simple and robust multi-site saturation mutagenesis (MSSM) method that enables simultaneously recombination of amino acid positions for focused mutant library generation. A general restriction enzyme-free and ligase-free MSSM method (Simple-MSSM) based on prolonged overlap extension PCR (POE-PCR) and Simple Cloning techniques. As a proof of principle of Simple-MSSM, the gene of eGFP (enhanced green fluorescent protein) was used as a template gene for simultaneous mutagenesis of five codons. Forty-eight randomly selected clones were sequenced. Sequencing revealed that all the 48 clones showed at least one mutant codon (mutation efficiency = 100%), and 46 out of the 48 clones had mutations at all the five codons. The obtained diversities at these five codons are 27, 24, 26, 26 and 22, respectively, which correspond to 84, 75, 81, 81, 69% of the theoretical diversity offered by NNK-degeneration (32 codons; NNK, K = T or G). The enzyme-free Simple-MSSM method can simultaneously and efficiently saturate five codons within one day, and therefore avoid missing interactions between residues in interacting amino acid networks.

  14. Settlement behavior of the container for high-level nuclear waste disposal. Centrifuge model tests and proposal for simple evaluation method for settlement behavior

    International Nuclear Information System (INIS)

    Nakamura, Kunihiko; Tanaka, Yukihisa

    2004-01-01

    In Japan, bentonite will be used as buffer materials in high-level nuclear waste disposal. In the softened buffer material with the infiltration of various properties of under ground water, if the container deeply sinks, the decrease of the thickness of the buffer materials may lose the required abilities. Therefore, it is very important to consider settlement of container. In this study, influences of distilled water and artificial seawater on the settlement of the container were investigated and a simple evaluation method for settlement of the container was proposed. The following findings were obtained from this study. (1) Under the distilled water, amount of settlement decreases exponentially as dry density becomes larger. (2) While the amount of settlement of container under the 10% artificial seawater was almost equal to the one in the distilled water, the container was floating under the 100% artificial seawater. (3) The simple evaluation method for settlement of container was proposed based on the diffuse double layer theory, and the effectiveness of the proposed method was demonstrated by the results of several experiments. (author)

  15. A Simple and Inexpensive Method for Evaluating the Photovoltaic Potential: Its Validation in Buenos Aires and Antarctica

    Directory of Open Access Journals (Sweden)

    Marcelo D. Cabezas

    2016-01-01

    Full Text Available The use of renewable energies requires a precise and detailed quantification of the resource available. Because of the cost of solar stations or limited availability of skilled human resources, in most emerging countries, this assessment is made only on a few points scattered over large areas. We report here a simple and inexpensive method to evaluate the photovoltaic (PV potential for a specific geographic region and a given PV capture technology. The system allows for a direct evaluation of the energy actually obtainable by scaling the measurement array of photovoltaic cells. The proposed measurement system can be installed as a stand-alone unit, or as part of a measurement network, connected to a more sophisticated central hub. The measurement station consists of said PV array (or similar PV array, a resistor, and a portable data logger. The system is calibrated with a device composed of a small array of PV cells, a resistor load bank, and two multimeters. Due to its low cost, this system can be replicated as many times as required with minimal investment. This would make it possible to evaluate the available photovoltaic potential of large regions with accurate and detailed data. Measurements carried out in Buenos Aires and in Antarctica confirm the consistency of the method.

  16. A statistical method for evaluation of the experimental phase equilibrium data of simple clathrate hydrates

    DEFF Research Database (Denmark)

    Eslamimanesh, Ali; Gharagheizi, Farhad; Mohammadi, Amir H.

    2012-01-01

    We, herein, present a statistical method for diagnostics of the outliers in phase equilibrium data (dissociation data) of simple clathrate hydrates. The applied algorithm is performed on the basis of the Leverage mathematical approach, in which the statistical Hat matrix, Williams Plot, and the r......We, herein, present a statistical method for diagnostics of the outliers in phase equilibrium data (dissociation data) of simple clathrate hydrates. The applied algorithm is performed on the basis of the Leverage mathematical approach, in which the statistical Hat matrix, Williams Plot...... in exponential form is used to represent/predict the hydrate dissociation pressures for three-phase equilibrium conditions (liquid water/ice–vapor-hydrate). The investigated hydrate formers are methane, ethane, propane, carbon dioxide, nitrogen, and hydrogen sulfide. It is interpreted from the obtained results...

  17. Simple gas chromatographic method for furfural analysis.

    Science.gov (United States)

    Gaspar, Elvira M S M; Lopes, João F

    2009-04-03

    A new, simple, gas chromatographic method was developed for the direct analysis of 5-hydroxymethylfurfural (5-HMF), 2-furfural (2-F) and 5-methylfurfural (5-MF) in liquid and water soluble foods, using direct immersion SPME coupled to GC-FID and/or GC-TOF-MS. The fiber (DVB/CAR/PDMS) conditions were optimized: pH effect, temperature, adsorption and desorption times. The method is simple and accurate (RSDfurfurals will contribute to characterise and quantify their presence in the human diet.

  18. A Comparison of Multidimensional Item Selection Methods in Simple and Complex Test Designs

    Directory of Open Access Journals (Sweden)

    Eren Halil ÖZBERK

    2017-03-01

    Full Text Available In contrast with the previous studies, this study employed various test designs (simple and complex which allow the evaluation of the overall ability score estimations across multiple real test conditions. In this study, four factors were manipulated, namely the test design, number of items per dimension, correlation between dimensions and item selection methods. Using the generated item and ability parameters, dichotomous item responses were generated in by using M3PL compensatory multidimensional IRT model with specified correlations. MCAT composite ability score accuracy was evaluated using absolute bias (ABSBIAS, correlation and the root mean square error (RMSE between true and estimated ability scores. The results suggest that the multidimensional test structure, number of item per dimension and correlation between dimensions had significant effect on item selection methods for the overall score estimations. For simple structure test design it was found that V1 item selection has the lowest absolute bias estimations for both long and short tests while estimating overall scores. As the model gets complex KL item selection method performed better than other two item selection method.

  19. Simple method for calculating island widths

    International Nuclear Information System (INIS)

    Cary, J.R.; Hanson, J.D.; Carreras, B.A.; Lynch, V.E.

    1989-01-01

    A simple method for calculating magnetic island widths has been developed. This method uses only information obtained from integrating along the closed field line at the island center. Thus, this method is computationally less intensive than the usual method of producing surfaces of section of sufficient detail to locate and resolve the island separatrix. This method has been implemented numerically and used to analyze the buss work islands of ATF. In this case the method proves to be accurate to at least within 30%. 7 refs

  20. Simple Calculation Programs for Biology Immunological Methods

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Immunological Methods. Computation of Ab/Ag Concentration from EISA data. Graphical Method; Raghava et al., 1992, J. Immuno. Methods 153: 263. Determination of affinity of Monoclonal Antibody. Using non-competitive ...

  1. A Simple and Automatic Method for Locating Surgical Guide Hole

    Science.gov (United States)

    Li, Xun; Chen, Ming; Tang, Kai

    2017-12-01

    Restoration-driven surgical guides are widely used in implant surgery. This study aims to provide a simple and valid method of automatically locating surgical guide hole, which can reduce operator's experiences and improve the design efficiency and quality of surgical guide. Few literatures can be found on this topic and the paper proposed a novel and simple method to solve this problem. In this paper, a local coordinate system for each objective tooth is geometrically constructed in CAD system. This coordinate system well represents dental anatomical features and the center axis of the objective tooth (coincide with the corresponding guide hole axis) can be quickly evaluated in this coordinate system, finishing the location of the guide hole. The proposed method has been verified by comparing two types of benchmarks: manual operation by one skilled doctor with over 15-year experiences (used in most hospitals) and automatic way using one popular commercial package Simplant (used in few hospitals).Both the benchmarks and the proposed method are analyzed in their stress distribution when chewing and biting. The stress distribution is visually shown and plotted as a graph. The results show that the proposed method has much better stress distribution than the manual operation and slightly better than Simplant, which will significantly reduce the risk of cervical margin collapse and extend the wear life of the restoration.

  2. Improving validation methods for molecular diagnostics: application of Bland-Altman, Deming and simple linear regression analyses in assay comparison and evaluation for next-generation sequencing.

    Science.gov (United States)

    Misyura, Maksym; Sukhai, Mahadeo A; Kulasignam, Vathany; Zhang, Tong; Kamel-Reid, Suzanne; Stockley, Tracy L

    2018-02-01

    A standard approach in test evaluation is to compare results of the assay in validation to results from previously validated methods. For quantitative molecular diagnostic assays, comparison of test values is often performed using simple linear regression and the coefficient of determination (R 2 ), using R 2 as the primary metric of assay agreement. However, the use of R 2 alone does not adequately quantify constant or proportional errors required for optimal test evaluation. More extensive statistical approaches, such as Bland-Altman and expanded interpretation of linear regression methods, can be used to more thoroughly compare data from quantitative molecular assays. We present the application of Bland-Altman and linear regression statistical methods to evaluate quantitative outputs from next-generation sequencing assays (NGS). NGS-derived data sets from assay validation experiments were used to demonstrate the utility of the statistical methods. Both Bland-Altman and linear regression were able to detect the presence and magnitude of constant and proportional error in quantitative values of NGS data. Deming linear regression was used in the context of assay comparison studies, while simple linear regression was used to analyse serial dilution data. Bland-Altman statistical approach was also adapted to quantify assay accuracy, including constant and proportional errors, and precision where theoretical and empirical values were known. The complementary application of the statistical methods described in this manuscript enables more extensive evaluation of performance characteristics of quantitative molecular assays, prior to implementation in the clinical molecular laboratory. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  3. A Simple Preparation Method for Diphosphoimidazole

    DEFF Research Database (Denmark)

    Rosenberg, T.

    1964-01-01

    A simple method for the preparation of diphosphoimidazole is presented that involves direct phosphorylation of imidazole by phosphorus oxychloride in alkaline aqueous solution. Details are given on the use of diphosphoimidazole in preparing sodium phosphoramidate and certain phosphorylated amino...

  4. A simple method for human peripheral blood monocyte Isolation

    Directory of Open Access Journals (Sweden)

    Marcos C de Almeida

    2000-04-01

    Full Text Available We describe a simple method using percoll gradient for isolation of highly enriched human monocytes. High numbers of fully functional cells are obtained from whole blood or buffy coat cells. The use of simple laboratory equipment and a relatively cheap reagent makes the described method a convenient approach to obtaining human monocytes.

  5. Simple Calculation Programs for Biology Other Methods

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Other Methods. Hemolytic potency of drugs. Raghava et al., (1994) Biotechniques 17: 1148. FPMAP: methods for classification and identification of microorganisms 16SrRNA. graphical display of restriction and fragment map of ...

  6. Simple method for the estimation of glomerular filtration rate

    Energy Technology Data Exchange (ETDEWEB)

    Groth, T [Group for Biomedical Informatics, Uppsala Univ. Data Center, Uppsala (Sweden); Tengstroem, B [District General Hospital, Skoevde (Sweden)

    1977-02-01

    A simple method is presented for indirect estimation of the glomerular filtration rate from two venous blood samples, drawn after a single injection of a small dose of (/sup 125/I)sodium iothalamate (10 ..mu..Ci). The method does not require exact dosage, as the first sample, taken after a few minutes (t=5 min) after injection, is used to normilize the value of the second sample, which should be taken in between 2 to 4 h after injection. The glomerular filtration rate, as measured by standard insulin clearance, may then be predicted from the logarithm of the normalized value and linear regression formulas with a standard error of estimate of the order of 1 to 2 ml/min/1.73 m/sup 2/. The slope-intercept method for direct estimation of glomerular filtration rate is also evaluated and found to significantly underestimate standard insulin clearance. The normalized 'single-point' method is concluded to be superior to the slope-intercept method and more sophisticated methods using curve fitting technique, with regard to predictive force and clinical applicability.

  7. Evaluation of a fast and simple sample preparation method for PBDE flame retardants and DDT pesticides in fish for analysis by ELISA compared with GC-MS/MS

    Science.gov (United States)

    A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography tandem mass spectrometry (LPGC-MS/MS), was evaluated for analysis of polybrominated diphenyl ethers (PBDEs) and dich...

  8. Safeguards Evaluation Method for evaluating vulnerability to insider threats

    International Nuclear Information System (INIS)

    Al-Ayat, R.A.; Judd, B.R.; Renis, T.A.

    1986-01-01

    As protection of DOE facilities against outsiders increases to acceptable levels, attention is shifting toward achieving comparable protection against insiders. Since threats and protection measures for insiders are substantially different from those for outsiders, new perspectives and approaches are needed. One such approach is the Safeguards Evaluation Method. This method helps in assessing safeguards vulnerabilities to theft or diversion of special nuclear meterial (SNM) by insiders. The Safeguards Evaluation Method-Insider Threat is a simple model that can be used by safeguards and security planners to evaluate safeguards and proposed upgrades at their own facilities. The method is used to evaluate the effectiveness of safeguards in both timely detection (in time to prevent theft) and late detection (after-the-fact). The method considers the various types of potential insider adversaries working alone or in collusion with other insiders. The approach can be used for a wide variety of facilities with various quantities and forms of SNM. An Evaluation Workbook provides documentation of the baseline assessment; this simplifies subsequent on-site appraisals. Quantitative evaluation is facilitated by an accompanying computer program. The method significantly increases an evaluation team's on-site analytical capabilities, thereby producing a more thorough and accurate safeguards evaluation

  9. A simple and feasible method of effectiveness evaluation on radioactive decontamination action

    International Nuclear Information System (INIS)

    Chen Lin; Geng Xiaobing; Sun Jian; Wang Jihong; Guo Lijun

    2012-01-01

    Radioactive decontamination is a vital task in nuclear emergency response. The assessment of decontamination effectiveness is of great importance to decision-making. An index system for effectiveness evaluation of radioactive decontamination action in nuclear emergency response is produced. A method of decontamination effectiveness evaluation based on analytic hierarchy process and fuzzy comprehensive evaluation is presented. Index weights are determined through analytic hierarchy process. And scores of objects in each hierarchy are judged by fuzzy comprehensive evaluation. Then comprehensive effectiveness of the top object can be obtained, which can offer a basis for decision-making of decontamination action. (authors)

  10. A Simple Method to Determine if a Music Information Retrieval System is a "Horse"

    DEFF Research Database (Denmark)

    Sturm, Bob L.

    2014-01-01

    We propose and demonstrate a simple method to determine if a music information retrieval (MIR) system is using factors irrelevant to the task for which it is designed. This is of critical importance to certain use cases, but cannot be accomplished using standard approaches to evaluation in MIR...

  11. Simple and inexpensive method for CT-guided stereotaxy

    Energy Technology Data Exchange (ETDEWEB)

    Wester, K; Sortland, O; Hauglie-Hanssen, E

    1981-01-01

    A simple and inexpensive method for CT-guided stereotaxy is described. The method requires neither sophisticated computer programs nor additional stereotactic equipment, such as special head holders for the CT, and can be easily obtained without technical assistance. The method is designed to yield the vertical coordinates.

  12. Biological evaluation and simple method for the synthesis of tetrahydrobenzo[a]xanthenes-11-one derivatives

    Directory of Open Access Journals (Sweden)

    Ali Akbari

    2017-01-01

    Full Text Available A simple method for the synthesis of Tetrahydrobenzo[a]xanthenes-11-one derivatives in the presence of BF3.SiO2, and its antibacterial activity was assessed against Pseudomonas syringae, Xanthomonas citi and Pectobacterium carotovorum. The structure of the isolated compounds has been determined by means of 1H/13C NMR and FT-IR spectroscopy. The reactions were carried out in water at room temperature for 5 h. This method has some advantages such as good to excellent yield, mild reaction condition, ease of operation and workup, high product purity and green process.

  13. Evaluation of IOTA Simple Ultrasound Rules to Distinguish Benign and Malignant Ovarian Tumours

    Science.gov (United States)

    Kaur, Amarjit; Mohi, Jaswinder Kaur; Sibia, Preet Kanwal; Kaur, Navkiran

    2017-01-01

    Introduction IOTA stands for International Ovarian Tumour Analysis group. Ovarian cancer is one of the common cancers in women and is diagnosed at later stage in majority. The limiting factor for early diagnosis is lack of standardized terms and procedures in gynaecological sonography. Introduction of IOTA rules has provided some consistency in defining morphological features of ovarian masses through a standardized examination technique. Aim To evaluate the efficacy of IOTA simple ultrasound rules in distinguishing benign and malignant ovarian tumours and establishing their use as a tool in early diagnosis of ovarian malignancy. Materials and Methods A hospital based case control prospective study was conducted. Patients with suspected ovarian pathology were evaluated using IOTA ultrasound rules and designated as benign or malignant. Findings were correlated with histopathological findings. Collected data was statistically analysed using chi-square test and kappa statistical method. Results Out of initial 55 patients, 50 patients were included in the final analysis who underwent surgery. IOTA simple rules were applicable in 45 out of these 50 patients (90%). The sensitivity for the detection of malignancy in cases where IOTA simple rules were applicable was 91.66% and the specificity was 84.84%. Accuracy was 86.66%. Classifying inconclusive cases as malignant, the sensitivity and specificity was 93% and 80% respectively. High level of agreement was found between USG and histopathological diagnosis with Kappa value as 0.323. Conclusion IOTA simple ultrasound rules were highly sensitive and specific in predicting ovarian malignancy preoperatively yet being reproducible, easy to train and use. PMID:28969237

  14. Note on a simple test method for estimaing J/sub Ic/

    International Nuclear Information System (INIS)

    Whipple, T.A.; McHenry, H.I.

    1980-01-01

    Fracture toughness testing is generally a time-consuming and expensive procedure; therefore, there has been a significant amount of effort directed toward developing an inexpensive and rapid method of estimating the fracture toughness of materials. In this paper, a simple method for estimating J/sub Ic/ through the use of small, notched, bend bars is evaluated. The test only involves the measurement of the energy necessary to fracture the sample. Initial tests on Fe-18Cr-3Ni-13Mn and 304L stainless steel at 76 and 4 0 K have yielded results consistent with other fracture toughness tests, for materials in the low- to medium-toughness range

  15. A simple and rapid method to estimate radiocesium in man

    International Nuclear Information System (INIS)

    Kindl, P.; Steger, F.

    1990-09-01

    A simple and rapid method for monitoring internal contamination of radiocesium in man was developed. This method is based on measurements of the γ-rays emitted from the muscular parts between the thights by a simple NaJ(Tl)-system. The experimental procedure, the calibration, the estimation of the body activity and results are explained and discussed. (Authors)

  16. Simple evaluation of groundwater flow and radionuclide transport at Aespoe

    International Nuclear Information System (INIS)

    Dverstorp, B.; Geier, J.; Voss, C.

    1996-12-01

    A simple evaluation of groundwater flux and potential for radionuclide transport at the Aespoe site, from fundamental hydrologic principles, indicates that, based upon data that are available from surface-based investigations, it is not possible to confirm that the bedrock has a high capacity to retard radionuclide release to the surface environment. This result is primarily due to the high spatial variability of hydraulic conductivity, and high uncertainty regarding the relationship among hydrologic and transport parameters within conductive elements of the bedrock. A comparison between Aespoe and seven other study sites in Sweden indicates that it is difficult or impossible to discriminate among these sites in terms of the geologic barrier function, based upon the types of data that are available from present-day methods of site characterization. Groundwater flux is evaluated by a one-dimensional application of Darcy's law to a set of simple, potential pathways for groundwater flow from the repository, which are chosen to yield an appraisal of the wide bounds of possible system behaviour. The configurations of the pathways are specified based on simple assumptions of flow-field structure, and hydraulic driving forces are specified from consideration of regional and local topographic differences. Results are expressed in terms of a parameter group that has been shown to control the barrier function. Comparisons with more detailed hydrological modelling of Aespoe show that, although a reduction in uncertainty is achieved, this reduction is not sufficient to distinguish between good and poor performance of the geologic barrier at the site. 38 refs

  17. Present status and future of simple measuring methods; Suishitsu kan`i sokutei gijutsu no genjo to hatten no hoko

    Energy Technology Data Exchange (ETDEWEB)

    Urano, K.; Ishii, S. [Yokohama National University, Yokohama (Japan)

    1998-05-10

    This paper discusses simple measuring methods for water quality. There are various purposes for measuring water quality. It is not necessary to measure the water quality in an official way by taking a lot of labor and cost. Simple measuring methods are often adopted. By applying simple methods, measuring points and frequency of main discharge processes can be increased, resulting in the detailed evaluation and monitoring. Easy safety check for earth filling waste and soil pollutants is realized. Daily inspection and atmospheric measurements at accidents and disasters are easily promoted. The simple methods require easy and rapid operation, sensibility, accuracy and reproducibility suitable for the purpose, small size apparatus, low cost for measurements, and safety against used harmful matters. Coloring reaction is utilized for most of the measuring principles of simple methods, which include tests using test papers, pack tests, colorimetric tests, and tests using photoelectric colorimeter. The bacteria detection includes titration methods using dropping bottles, tablets and syringes, and tests using test papers. A measuring kit for the enzyme immunity method is commercialized. Cooperation of experts, measuring operators at the site and citizens is also indispensable. 7 refs., 3 figs., 2 tabs.

  18. The simple method to co-register planar image with photograph

    International Nuclear Information System (INIS)

    Jang, Sung June; Kim, Seok Ki; Kang, Keon Wook

    2005-01-01

    Generally scintigraphic image presents the highly specific functional information. Sometimes, there can be limited information of patients anatomical landmark required to identify the lesion in planar nuclear medicine image. In this study, we applied the simple fusion method of planar scintigraphy and plain photography and validated the techniques with our own software. We used three fiducial marks which were comprised with Tc-99m. We obtained planar image with single head gamma camera (ARGUS ADAC laboratory, USA) and photograph using a general digital camera (CANON JAPAN). The coordinates of three marks were obtained in photograph and planar scintigraphy image. Based on these points, we took affine transformation and then fused these two images. To evaluate the precision, we compared with different depth. To find out the depth of lesion, the images were acquired in different angles and we compared the real depth and the geometrically calculated depth. At the same depth with mark, the each discordance was less than 1 mm. When the photograph were taken at the distance with 1 m and 2 m, the point 30 cm off the center were discordant in 5 mm and 2 mm each. We used this method in the localization of the remnant thyroid tissue on I-131 whole body scan with photo image. The simple method to co-register planar image with photography was reliable and easy to use. By this method, we could localize the lesion on the planar scintigraphy more accurately with other planar images (i.e. photograph) and predict the depth of the lesion without tomographic image

  19. Validity of a Simple Method for Measuring Force-Velocity-Power Profile in Countermovement Jump.

    Science.gov (United States)

    Jiménez-Reyes, Pedro; Samozino, Pierre; Pareja-Blanco, Fernando; Conceição, Filipe; Cuadrado-Peñafiel, Víctor; González-Badillo, Juan José; Morin, Jean-Benoît

    2017-01-01

    To analyze the reliability and validity of a simple computation method to evaluate force (F), velocity (v), and power (P) output during a countermovement jump (CMJ) suitable for use in field conditions and to verify the validity of this computation method to compute the CMJ force-velocity (F-v) profile (including unloaded and loaded jumps) in trained athletes. Sixteen high-level male sprinters and jumpers performed maximal CMJs under 6 different load conditions (0-87 kg). A force plate sampling at 1000 Hz was used to record vertical ground-reaction force and derive vertical-displacement data during CMJ trials. For each condition, mean F, v, and P of the push-off phase were determined from both force-plate data (reference method) and simple computation measures based on body mass, jump height (from flight time), and push-off distance and used to establish the linear F-v relationship for each individual. Mean absolute bias values were 0.9% (± 1.6%), 4.7% (± 6.2%), 3.7% (± 4.8%), and 5% (± 6.8%) for F, v, P, and slope of the F-v relationship (S Fv ), respectively. Both methods showed high correlations for F-v-profile-related variables (r = .985-.991). Finally, all variables computed from the simple method showed high reliability, with ICC >.980 and CV push-off distance, and jump height are known.

  20. A simple micro-photometric method for urinary iodine determination.

    Science.gov (United States)

    Grimm, Gabriele; Lindorfer, Heidelinde; Kieweg, Heidi; Marculescu, Rodrig; Hoffmann, Martha; Gessl, Alois; Sager, Manfred; Bieglmayer, Christian

    2011-10-01

    Urinary iodide concentration (UIC) is useful to evaluate nutritional iodine status. In clinical settings UIC helps to exclude blocking of the thyroid gland by excessive endogenous iodine, if diagnostic or therapeutic administration of radio-iodine is indicated. Therefore, this study established a simple test for the measurement of UIC. UIC was analyzed in urine samples of 200 patients. Samples were pre-treated at 95°C for 45 min with ammonium persulfate in a thermal cycler, followed by a photometric Sandell-Kolthoff reaction (SK) carried out in microtiter plates. For method comparison, UIC was analyzed in 30 samples by inductivity coupled plasma mass spectro-metry (ICP-MS) as a reference method. Incubation conditions were optimized concerning recovery. The photometric test correlated well to the reference method (SK=0.91*ICP-MS+1, r=0.962) and presented with a functional sensitivity of 20 μg/L. UIC of patient samples ranged from photometric test provides satisfactory results and can be performed with the basic equipment of a clinical laboratory.

  1. A simple approximation method for dilute Ising systems

    International Nuclear Information System (INIS)

    Saber, M.

    1996-10-01

    We describe a simple approximate method to analyze dilute Ising systems. The method takes into consideration the fluctuations of the effective field, and is based on a probability distribution of random variables which correctly accounts for all the single site kinematic relations. It is shown that the simplest approximation gives satisfactory results when compared with other methods. (author). 12 refs, 2 tabs

  2. A simple method to approximate liver size on cross-sectional images using living liver models

    International Nuclear Information System (INIS)

    Muggli, D.; Mueller, M.A.; Karlo, C.; Fornaro, J.; Marincek, B.; Frauenfelder, T.

    2009-01-01

    Aim: To assess whether a simple. diameter-based formula applicable to cross-sectional images can be used to calculate the total liver volume. Materials and methods: On 119 cross-sectional examinations (62 computed tomography and 57 magnetic resonance imaging) a simple, formula-based method to approximate the liver volume was evaluated. The total liver volume was approximated measuring the largest craniocaudal (cc), ventrodorsal (vd), and coronal (cor) diameters by two readers and implementing the equation: Vol estimated =ccxvdxcorx0.31. Inter-rater reliability, agreement, and correlation between liver volume calculation and virtual liver volumetry were analysed. Results: No significant disagreement between the two readers was found. The formula correlated significantly with the volumetric data (r > 0.85, p < 0.0001). In 81% of cases the error of the approximated volume was <10% and in 92% of cases <15% compared to the volumetric data. Conclusion: Total liver volume can be accurately estimated on cross-sectional images using a simple, diameter-based equation.

  3. Quantitative evaluation of the lung cancer deaths attributable to residential radon: A simple method and results for all the 21 Italian Regions

    International Nuclear Information System (INIS)

    Bochicchio, F.; Antignani, S.; Venoso, G.; Forastiere, F.

    2013-01-01

    Pooled analyses of epidemiological case-control studies on lung cancer and residential radon have shown that radon exposure in dwellings increases lung cancer risk, and that the increase is statistically significant also for prolonged exposures to low-medium level of radon concentration, i.e. levels commonly found in many dwellings. In this paper, a simple method to evaluate the health burden due to the presence of radon in homes (i.e. the number of lung cancer deaths attributable to radon exposure in dwellings) was presented. This method is based on the following parameters: i) the excess relative risk per unit of exposure evaluated in case-control studies; ii) the average radon concentration that can be considered representative of population exposure in dwellings; iii) the total number of lung cancer deaths occurring each year. Moreover, the interaction between radon and cigarette smoking is needed to be taken into account: in fact, although most of the persons are non-smokers, most of the lung cancer deaths attributed to radon are actually due to the multiplicative effect of radon and cigarette smoking. To show this effect, the number of radon related lung cancer deaths estimated to occur among current, former and never smokers was calculated separately for males and females, taking into account the relative risk of lung cancer for the different smoking categories and the prevalence of smoking habits. The methodology described in this work was applied to all the 21 Italian Regions in order to illustrate it. The overall fraction of lung cancer deaths attributable to radon in Italy is about 10%, with values in individual Regions ranging from 4% to 16%. The greater part of the lung cancers attributable to radon is estimated to occur among current smokers for both males and females (72% and 60%, respectively, at national level). This is due to the synergistic effects of radon and cigarette smoking, which should therefore be taken into account in policies aimed to

  4. [Analysis on the accuracy of simple selection method of Fengshi (GB 31)].

    Science.gov (United States)

    Li, Zhixing; Zhang, Haihua; Li, Suhe

    2015-12-01

    To explore the accuracy of simple selection method of Fengshi (GB 31). Through the study of the ancient and modern data,the analysis and integration of the acupuncture books,the comparison of the locations of Fengshi (GB 31) by doctors from all dynasties and the integration of modern anatomia, the modern simple selection method of Fengshi (GB 31) is definite, which is the same as the traditional way. It is believed that the simple selec tion method is in accord with the human-oriented thought of TCM. Treatment by acupoints should be based on the emerging nature and the individual difference of patients. Also, it is proposed that Fengshi (GB 31) should be located through the integration between the simple method and body surface anatomical mark.

  5. Gallium determination with Rodamina B: a simple method

    International Nuclear Information System (INIS)

    Queiroz, R.R.U. de.

    1981-01-01

    A simple method for determining gallium with Rhodamine B, by the modification of the method proposed by Onishi and Sandell. The complex (RH) GaCl 4 is extracted with a mixture benzene-ethylacetate (3:1 V/V), from an aqueous medium 6 M in hydrochloric acid. The interference of foreign ions is studied. (C.G.C.) [pt

  6. A simple and efficient electrochemical reductive method for ...

    Indian Academy of Sciences (India)

    Administrator

    This approach opens up a new, practical and green reducing method to prepare large- scale graphene. ... has the following significant advantages: (1) It is simple to operate. .... The authors thank the National High Technology Research.

  7. Solution of the schrodinger equation in one dimension by simple method for a simple step potential

    International Nuclear Information System (INIS)

    Ertik, H.

    2005-01-01

    The coefficients of the transmission and reflection for the simple-step barrier potential were calculated by a simple method. Their values were entirely different from those often encountered in the literature. Especially in the case that the total energy is equal to the barrier potential, the value of 0,20 for the reflection coefficient was obtained whereas this is zero in the literature. This may be considered as an interesting point

  8. Evaluation of IOTA Simple Ultrasound Rules to Distinguish Benign and Malignant Ovarian Tumours.

    Science.gov (United States)

    Garg, Sugandha; Kaur, Amarjit; Mohi, Jaswinder Kaur; Sibia, Preet Kanwal; Kaur, Navkiran

    2017-08-01

    IOTA stands for International Ovarian Tumour Analysis group. Ovarian cancer is one of the common cancers in women and is diagnosed at later stage in majority. The limiting factor for early diagnosis is lack of standardized terms and procedures in gynaecological sonography. Introduction of IOTA rules has provided some consistency in defining morphological features of ovarian masses through a standardized examination technique. To evaluate the efficacy of IOTA simple ultrasound rules in distinguishing benign and malignant ovarian tumours and establishing their use as a tool in early diagnosis of ovarian malignancy. A hospital based case control prospective study was conducted. Patients with suspected ovarian pathology were evaluated using IOTA ultrasound rules and designated as benign or malignant. Findings were correlated with histopathological findings. Collected data was statistically analysed using chi-square test and kappa statistical method. Out of initial 55 patients, 50 patients were included in the final analysis who underwent surgery. IOTA simple rules were applicable in 45 out of these 50 patients (90%). The sensitivity for the detection of malignancy in cases where IOTA simple rules were applicable was 91.66% and the specificity was 84.84%. Accuracy was 86.66%. Classifying inconclusive cases as malignant, the sensitivity and specificity was 93% and 80% respectively. High level of agreement was found between USG and histopathological diagnosis with Kappa value as 0.323. IOTA simple ultrasound rules were highly sensitive and specific in predicting ovarian malignancy preoperatively yet being reproducible, easy to train and use.

  9. A Simple Response Evaluation Method for Base-Isolation Building-Connection Hybrid Structural System under Long-Period and Long-Duration Ground Motion

    Directory of Open Access Journals (Sweden)

    Kohei Hayashi

    2018-02-01

    Full Text Available An innovative hybrid control building system of base-isolation and building-connection has been proposed in the previous study. This system has two advantages, (i to resist an impulsive earthquake input through the base-isolation system and (ii to withstand a long-duration earthquake input through the building-connection system. A simple response evaluation method without the need of non-linear time–history response analysis is proposed here for this hybrid building system under a long-period and long-duration ground motion. An analytical expression is derived in the plastic deformation of an elastic–perfectly plastic single-degree-of-freedom (SDOF model with viscous damping under the multi-impulse, which is the representative of long-period and long-duration ground motions. A transformation procedure of a base-isolation building-connection hybrid structural system into an SDOF model is proposed by introducing two steps, one is the reduction of the main base-isolated building to an SDOF system, and the other is the reduction of the connecting oil dampers supported on a free-wall to an oil damper with a newly introduced compensation factor on a rigid wall. Application of the analytical expression of the plastic deformation to the reduced SDOF model including the compensation factor on the connecting oil dampers enables the development of a simplified, but rather accurate response evaluation method. The time–history response analysis of the multi-degree-of-freedom model and the comparison with the proposed simplified formula make clear the accuracy and reliability of the proposed simplified response evaluation method.

  10. A Simple HPLC Bioanalytical Method for the Determination of ...

    African Journals Online (AJOL)

    Purpose: To develop a simple, accurate, and precise high performance chromatography (HPLC) method with spectrophotometric detection for the determination of doxorubicin hydrochloride in rat plasma. Methods: Doxorubicin hydrochloride and daunorubicin hydrochloride (internal standard, IS) were separated on a C18 ...

  11. Benchmark calculations for evaluation methods of gas volumetric leakage rate

    International Nuclear Information System (INIS)

    Asano, R.; Aritomi, M.; Matsuzaki, M.

    1998-01-01

    A containment function of radioactive materials transport casks is essential for safe transportation to prevent the radioactive materials from being released into environment. Regulations such as IAEA standard determined the limit of radioactivity to be released. Since is not practical for the leakage tests to measure directly the radioactivity release from a package, as gas volumetric leakages rates are proposed in ANSI N14.5 and ISO standards. In our previous works, gas volumetric leakage rates for several kinds of gas from various leaks were measured and two evaluation methods, 'a simple evaluation method' and 'a strict evaluation method', were proposed based on the results. The simple evaluation method considers the friction loss of laminar flow with expansion effect. The strict evaluating method considers an exit loss in addition to the friction loss. In this study, four worked examples were completed for on assumed large spent fuel transport cask (Type B Package) with wet or dry capacity and at three transport conditions; normal transport with intact fuels or failed fuels, and an accident in transport. The standard leakage rates and criteria for two kinds of leak test were calculated for each example by each evaluation method. The following observations are made based upon the calculations and evaluations: the choked flow model of ANSI method greatly overestimates the criteria for tests ; the laminar flow models of both ANSI and ISO methods slightly overestimate the criteria for tests; the above two results are within the design margin for ordinary transport condition and all methods are useful for the evaluation; for severe condition such as failed fuel transportation, it should pay attention to apply a choked flow model of ANSI method. (authors)

  12. A simple method of digitizing analog scintigrams for quantification and digital archiving

    International Nuclear Information System (INIS)

    Schramm, M.; Kaempfer, B.; Wolf, H.; Clausen, M.; Wendhausen, H.; Henze, E.

    1993-01-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on X-ray film were then digitized seecondarily by three different methods: 300 dpi flatbed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification. (orig.) [de

  13. [A simple method of digitizing analog scintigrams for quantification and digital archiving].

    Science.gov (United States)

    Schramm, M; Kämpfer, B; Wolf, H; Clausen, M; Wendhausen, H; Henze, E

    1993-02-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on x-ray film were then digitized secondarily by three different methods: 300 dpi flat-bed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification.

  14. Simple measurement of 14C in the environment using a gel suspension method

    International Nuclear Information System (INIS)

    Wakabayashi, G.; Ohura, H.; Okai, T.; Matoba, M.

    1999-01-01

    A simple analytical method for environmental 14 C with a low background liquid scintillation counter was developed. A new gelling agent, N-lauroyl-L-glutamic-α,γ-dibutylamide was used, for the liquid scintillation counting of 14 C as CaCO 3 (gel suspension method). Our procedure for sample preparation was much simpler than that of conventional methods and required no special equipment. The samples prepared with the standard sample of CaCO 3 were measured to evaluate the self absorption of the sample, the optimum condition of counting and the detection limit. Our results indicated that the newly developed technique could be efficiently applied for the monitoring of environmental 14 C. (author)

  15. A simple method for multiday imaging of slice cultures.

    Science.gov (United States)

    Seidl, Armin H; Rubel, Edwin W

    2010-01-01

    The organotypic slice culture (Stoppini et al. A simple method for organotypic cultures of nervous tissue. 1991;37:173-182) has become the method of choice to answer a variety of questions in neuroscience. For many experiments, however, it would be beneficial to image or manipulate a slice culture repeatedly, for example, over the course of many days. We prepared organotypic slice cultures of the auditory brainstem of P3 and P4 mice and kept them in vitro for up to 4 weeks. Single cells in the auditory brainstem were transfected with plasmids expressing fluorescent proteins by way of electroporation (Haas et al. Single-cell electroporation for gene transfer in vivo. 2001;29:583-591). The culture was then placed in a chamber perfused with oxygenated ACSF and the labeled cell imaged with an inverted wide-field microscope repeatedly for multiple days, recording several time-points per day, before returning the slice to the incubator. We describe a simple method to image a slice culture preparation during the course of multiple days and over many continuous hours, without noticeable damage to the tissue or photobleaching. Our method uses a simple, inexpensive custom-built insulator constructed around the microscope to maintain controlled temperature and uses a perfusion chamber as used for in vitro slice recordings. (c) 2009 Wiley-Liss, Inc.

  16. Simple Synthesis Method for Alumina Nanoparticle

    Directory of Open Access Journals (Sweden)

    Daniel Damian

    2017-11-01

    Full Text Available Globally, the human population steady increase, expansion of urban areas, excessive industrialization including in agriculture, caused not only decrease to depletion of non-renewable resources, a rapid deterioration of the environment with negative impact on water quality, soil productivity and of course quality of life in general. This paper aims to prepare size controlled nanoparticles of aluminum oxide using a simple synthesis method. The morphology and dimensions of nanomaterial was investigated using modern analytical techniques: SEM/EDAX and XRD spectroscopy.

  17. Percutaneous Method of Management of Simple Bone Cyst

    Directory of Open Access Journals (Sweden)

    O. P. Lakhwani

    2013-01-01

    Full Text Available Introduction. Simple bone cyst or unicameral bone cysts are benign osteolytic lesions seen in metadiaphysis of long bones in growing children. Various treatment modalities with variable outcomes have been described in the literature. The case report illustrates the surgical technique of minimally invasive method of treatment. Case Study. A 14-year-old boy was diagnosed as active simple bone cyst proximal humerus with pathological fracture. The patient was treated by minimally invasive percutaneous curettage with titanium elastic nail (TENS and allogenic bone grafting mixed with bone marrow under image intensifier guidance. Results. Pathological fracture was healed and allograft filled in the cavity was well taken up. The patient achieved full range of motion with successful outcome. Conclusion. Minimally invasive percutaneous method using elastic intramedullary nail gives benefit of curettage cyst decompression and stabilization of fracture. Allogenic bone graft fills the cavity and healing of lesion by osteointegration. This method may be considered with advantage of minimally invasive technique in treatment of benign cystic lesions of bone, and the level of evidence was therapeutic level V.

  18. Percutaneous Method of Management of Simple Bone Cyst

    Science.gov (United States)

    Lakhwani, O. P.

    2013-01-01

    Introduction. Simple bone cyst or unicameral bone cysts are benign osteolytic lesions seen in metadiaphysis of long bones in growing children. Various treatment modalities with variable outcomes have been described in the literature. The case report illustrates the surgical technique of minimally invasive method of treatment. Case Study. A 14-year-old boy was diagnosed as active simple bone cyst proximal humerus with pathological fracture. The patient was treated by minimally invasive percutaneous curettage with titanium elastic nail (TENS) and allogenic bone grafting mixed with bone marrow under image intensifier guidance. Results. Pathological fracture was healed and allograft filled in the cavity was well taken up. The patient achieved full range of motion with successful outcome. Conclusion. Minimally invasive percutaneous method using elastic intramedullary nail gives benefit of curettage cyst decompression and stabilization of fracture. Allogenic bone graft fills the cavity and healing of lesion by osteointegration. This method may be considered with advantage of minimally invasive technique in treatment of benign cystic lesions of bone, and the level of evidence was therapeutic level V. PMID:23819089

  19. A simple method for α determination

    International Nuclear Information System (INIS)

    Ho Manh Dung; Seung Yeon Cho

    2003-01-01

    The a term is a primary parameter that is used to indicate the deviation of the epithermal neutron distribution in the k 0 -standardization method of neutron activation analysis, k 0 -NAA. The calculation of a using a mathematical procedure is a challenge for some researchers. The calculation of a by the 'bare-triple monitor' method is possible using the dedicated commercial software KAYZERO R /SOLCOI R . However, when this software is not available in the laboratory it is possible to carry out the calculation of a applying a simple iterative linear regression using any spreadsheets. This approach is described. The experimental data used in the example were obtained by the irradiation of a set of suitable monitors in the NAA no.1 irradiation channel of the HANARO research reactor (KAERI, Korea). The results obtained by this iterative linear regression method agree well with the results calculated by the validated mathematical method. (author)

  20. Ruminal Methane Production on Simple Phenolic Acids Addition in in Vitro Gas Production Method

    Directory of Open Access Journals (Sweden)

    A. Jayanegara

    2009-04-01

    Full Text Available Methane production from ruminants contributes to total global methane production, which is an important contributor to global warming. In this experiment, six sources of simple phenolic acids (benzoic, cinnamic, phenylacetic, caffeic, p-coumaric and ferulic acids at two different levels (2 and 5 mM added to hay diet were evaluated for their potential to reduce enteric methane production using in vitro Hohenheim gas production method. The measured variables were gas production, methane, organic matter digestibility (OMD, and short chain fatty acids (SCFA. The results showed that addition of cinnamic, caffeic, p-coumaric and ferulic acids at 5 mM significantly (P p-coumaric > ferulic > cinnamic. The addition of simple phenols did not significantly decrease OMD. Addition of simple phenols tends to decrease total SCFA production. It was concluded that methane decrease by addition of phenolic acids was relatively small, and the effect of phenolic acids on methane decrease depended on the source and concentration applied.

  1. Simple equation method for nonlinear partial differential equations and its applications

    Directory of Open Access Journals (Sweden)

    Taher A. Nofal

    2016-04-01

    Full Text Available In this article, we focus on the exact solution of the some nonlinear partial differential equations (NLPDEs such as, Kodomtsev–Petviashvili (KP equation, the (2 + 1-dimensional breaking soliton equation and the modified generalized Vakhnenko equation by using the simple equation method. In the simple equation method the trial condition is the Bernoulli equation or the Riccati equation. It has been shown that the method provides a powerful mathematical tool for solving nonlinear wave equations in mathematical physics and engineering problems.

  2. A simple finite element method for linear hyperbolic problems

    International Nuclear Information System (INIS)

    Mu, Lin; Ye, Xiu

    2017-01-01

    Here, we introduce a simple finite element method for solving first order hyperbolic equations with easy implementation and analysis. Our new method, with a symmetric, positive definite system, is designed to use discontinuous approximations on finite element partitions consisting of arbitrary shape of polygons/polyhedra. Error estimate is established. Extensive numerical examples are tested that demonstrate the robustness and flexibility of the method.

  3. A Simple Analytical Method Using HPLC with Fluorescence Detection to Determine Selected Polycyclic Aromatic Compounds in Filter Samples

    International Nuclear Information System (INIS)

    Garcia, S.; Perez, R. M.

    2014-01-01

    A study on the comparison and evaluation of a miniaturized extraction method for the determination of selected PACs in sample filters is presented. The main objective was the optimization and development of simple, rapid and low cost methods, minimizing the use of extracting solvent volume. The work also includes a study on the intermediate precision. (Author)

  4. Simple Calculation Programs for Biology Methods in Molecular ...

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Simple Calculation Programs for Biology Methods in Molecular Biology. GMAP: A program for mapping potential restriction sites. RE sites in ambiguous and non-ambiguous DNA sequence; Minimum number of silent mutations required for introducing a RE sites; Set ...

  5. Methods for evaluating information sources

    DEFF Research Database (Denmark)

    Hjørland, Birger

    2012-01-01

    The article briefly presents and discusses 12 different approaches to the evaluation of information sources (for example a Wikipedia entry or a journal article): (1) the checklist approach; (2) classical peer review; (3) modified peer review; (4) evaluation based on examining the coverage...... of controversial views; (5) evidence-based evaluation; (6) comparative studies; (7) author credentials; (8) publisher reputation; (9) journal impact factor; (10) sponsoring: tracing the influence of economic, political, and ideological interests; (11) book reviews and book reviewing; and (12) broader criteria....... Reading a text is often not a simple process. All the methods discussed here are steps on the way on learning how to read, understand, and criticize texts. According to hermeneutics it involves the subjectivity of the reader, and that subjectivity is influenced, more or less, by different theoretical...

  6. A SIMPLE METHOD FOR THE EXTRACTION AND QUANTIFICATION OF PHOTOPIGMENTS FROM SYMBIODINIUM SPP.

    Science.gov (United States)

    John E. Rogers and Dragoslav Marcovich. Submitted. Simple Method for the Extraction and Quantification of Photopigments from Symbiodinium spp.. Limnol. Oceanogr. Methods. 19 p. (ERL,GB 1192). We have developed a simple, mild extraction procedure using methanol which, when...

  7. A simple flow-concentration modelling method for integrating water ...

    African Journals Online (AJOL)

    A simple flow-concentration modelling method for integrating water quality and ... flow requirements are assessed for maintenance low flow, drought low flow ... the instream concentrations of chemical constituents that will arise from different ...

  8. A simple and secure method to fix laparoscopic trocars in children.

    Science.gov (United States)

    Yip, K F; Tam, P K H; Li, M K W

    2006-04-01

    We introduce a simple method of fixing trocars to the abdominal wall in children. Before anchoring the trocar, a piece of Tegaderm polyurethrane adhesive (3M Healthcare, St. Paul, Minnesota) is attached to the trocar. A silk stitch is anchored to neighboring skin, and then transfixed over the shaft of the trocar through the adhesive. Both inward and outward movement of the trocar can be restrained. This method is simple, fast, secure, and can be applied to trocars of any size.

  9. The efficiency of the centroid method compared to a simple average

    DEFF Research Database (Denmark)

    Eskildsen, Jacob Kjær; Kristensen, Kai; Nielsen, Rikke

    Based on empirical data as well as a simulation study this paper gives recommendations with respect to situations wheere a simple avarage of the manifest indicators can be used as a close proxy for the centroid method and when it cannot.......Based on empirical data as well as a simulation study this paper gives recommendations with respect to situations wheere a simple avarage of the manifest indicators can be used as a close proxy for the centroid method and when it cannot....

  10. A simple statistical method for catch comparison studies

    DEFF Research Database (Denmark)

    Holst, René; Revill, Andrew

    2009-01-01

    For analysing catch comparison data, we propose a simple method based on Generalised Linear Mixed Models (GLMM) and use polynomial approximations to fit the proportions caught in the test codend. The method provides comparisons of fish catch at length by the two gears through a continuous curve...... with a realistic confidence band. We demonstrate the versatility of this method, on field data obtained from the first known testing in European waters of the Rhode Island (USA) 'Eliminator' trawl. These data are interesting as they include a range of species with different selective patterns. Crown Copyright (C...

  11. Development of a simple chromatographic method for the determination of piracetam in human plasma and its pharmacokinetic evaluation.

    Science.gov (United States)

    Barkat, K; Ahmad, M; Minhas, M U; Malik, M Z; Sohail, M

    2014-07-01

    The objective of study was to develop an accurate and reproducible HPLC method for determination of piracetam in human plasma and to evaluate pharmacokinetic parameters of 800 mg piracetam. A simple, rapid, accurate, precise and sensitive high pressure liquid chromatography method has been developed and subsequently validated for determination of piracetam. This study represents the results of a randomized, single-dose and single-period in 18 healthy male volunteers to assess pharmacokinetic parameters of 800 mg piracetam tablets. Various pharmacokinetic parameters were determined from plasma for piracetam and found to be in good agreement with previous reported values. The data was analyzed by using Kinetica® version 4.4 according to non-compartment model of pharmacokinetic analysis and after comparison with previous studies, no significant differences were found in present study of tested product. The major pharmacokinetic parameters for piracetam were as follows: t1/2 was (4.40 ± 0.179) h; Tmax value was (2.33 ± 0.105) h; Cmax was (14.53 ± 0.282) µg/mL; the AUC(0-∞) was (59.19 ± 4.402) µg · h/mL. AUMC(0-∞) was (367.23 ± 38.96) µg. (h)(2)/mL; Ke was (0.16 ± 0.006) h; MRT was (5.80 ± 0.227) h; Vd was (96.36 ± 8.917 L). A rapid, accurate and precise high pressure liquid chromatography method was developed and validated before the study. It is concluded that this method is very useful for the analysis of pharmacokinetic parameters, in human plasma and assured the safety and efficacy of piracetam, can be effectively used in medical practice. © Georg Thieme Verlag KG Stuttgart · New York.

  12. Simple Design Method for Magnetic Shield Room(The 20th MAGDA Conference in Pacific Asia (MAGDA2011))

    OpenAIRE

    Keisuke, FUJISAKI; Masahiro, FUJIKURA; Jirou, MINO; Nippon Steel Corporation:Toyota Technological Institute; Nippon Steel Corporation; Nippon Steel Engineering Co., Ltd

    2012-01-01

    As a primary evaluation of the magnetic shield room design, a simple design method is proposed here. The steel sheet number of the magnetic shield room is designed so as to make the distributed magnetic flux density from the exciting coil catch the magnetic shield body. The proposed method is applied to a full-scale magnetic shield room and the leakage magnetic flux density is evaluated by numerical calculation. Though it introduces a large steel number of the magnetic shield body, the leakag...

  13. A simple three dimensional wide-angle beam propagation method

    Science.gov (United States)

    Ma, Changbao; van Keuren, Edward

    2006-05-01

    The development of three dimensional (3-D) waveguide structures for chip scale planar lightwave circuits (PLCs) is hampered by the lack of effective 3-D wide-angle (WA) beam propagation methods (BPMs). We present a simple 3-D wide-angle beam propagation method (WA-BPM) using Hoekstra’s scheme along with a new 3-D wave equation splitting method. The applicability, accuracy and effectiveness of our method are demonstrated by applying it to simulations of wide-angle beam propagation and comparing them with analytical solutions.

  14. Fast and Simple Method for Evaluation of Polarization Correction to Propagation Constant of Arbitrary Order Guided Modes in Optical Fibers with Arbitrary Refractive Index Profile

    Directory of Open Access Journals (Sweden)

    Anton Bourdine

    2015-01-01

    Full Text Available This work presents fast and simple method for evaluation of polarization correction to scalar propagation constant of arbitrary order guided modes propagating over weakly guiding optical fibers. Proposed solution is based on earlier on developed modified Gaussian approximation extended for analysis of weakly guiding optical fibers with arbitrary refractive index profile in the core region bounded by single solid outer cladding. Some results are presented that illustrate the decreasing of computational error during the estimation of propagation constant when polarization corrections are taken into account. Analytical expressions for the first and second derivatives of polarization correction are derived and presented.

  15. Simple methods of aligning four-circle diffractometers with crystal reflections

    Energy Technology Data Exchange (ETDEWEB)

    Mitsui, Y [Tokyo Univ. (Japan). Faculty of Pharmaceutical Sciences

    1979-08-01

    Simple methods of aligning four-circle diffractometers with crystal reflections are devised. They provide the methods to check (1) perpendicularity of chi plane to the incident beam, (2) zero point of 2theta and linearity of focus-chi center-receiving aperture and (3) zero point of chi.

  16. Simple PVT quantitative method of Kr under high pure N2 condition

    International Nuclear Information System (INIS)

    Li Xuesong; Zhang Zibin; Wei Guanyi; Chen Liyun; Zhai Lihua

    2005-01-01

    A simple PVT quantitative method of Kr in the high pure N 2 was studied. Pressure, volume and temperature of the sample gas were measured by three individual methods to obtain the sum sample with food uncertainty. The ratio of Kr/N 2 could measured by GAM 400 quadrupole mass spectrometer. So the quantity of Kr could be calculated with the two measured data above. This method can be suited for quantitative analysis of other simple composed noble gas sample with high pure carrying gas. (authors)

  17. Pregabalin and Tranexamic Acid Evaluation by Two Simple and Sensitive Spectrophotometric Methods

    Directory of Open Access Journals (Sweden)

    Nawab Sher

    2015-01-01

    Full Text Available This paper demonstrates colorimetric visible spectrophotometric quantification methods for amino acid, namely, tranexamic acid and pregabalin. Both drugs contain the amino group, and when they are reacted with 2,4-dinitrophenol and 2,4,6-trinitrophenol, they give rise to yellow colored complexes showing absorption maximum at 418 nm and 425 nm, respectively, based on the Lewis acid base reaction. Detailed optimization process and stoichiometric studies were conducted along with investigation of thermodynamic features, that is, association constant and standard free energy changes. The method was linear over the concentration range of 0.02–200 µgmL−1 with correlation coefficient of more than 0.9990 in all of the cases. Limit of detection was in range from 0.0041 to 0.0094 µgmL−1 and limit of quantification was in the range from 0.0137 to 0.0302 µgmL−1. Excellent recovery in Placebo spiked samples indicated that there is no interference from common excipients. The analytical methods under proposal were successfully applied to determine tranexamic acid and pregabalin in commercial products. t-test and F ratio were evaluated without noticeable difference between the proposed and reference methods.

  18. A Simple Method for Closure of Urethrocutaneous Fistula after Tubularized Incised Plate Repair: Preliminary Results.

    Science.gov (United States)

    Shirazi, Mehdi; Ariafar, Ali; Babaei, Amir Hossein; Ashrafzadeh, Abdosamad; Adib, Ali

    2016-11-01

    Urethrocutaneous fistula (UCF) is the most prevalent complication after hypospadias repair surgery. Many methods have been developed for UCF correction, and the best technique for UCF repair is determined based on the size, location, and number of fistulas, as well as the status of the surrounding skin. In this study, we introduced and evaluated a simple method for UCF correction after tubularized incised plate (TIP) repair. This clinical study was conducted on children with UCFs ≤ 4 mm that developed after TIP surgery for hypospadias repair. The skin was incised around the fistula and the tract was released from the surrounding tissues and the dartos fascia, then ligated with 5 - 0 polydioxanone (PDS) sutures. The dartos fascia, as the second layer, was covered on the fistula tract with PDS thread (gauge 5 - 0) by the continuous suture method. The skin was closed with 6 - 0 Vicryl sutures. After six months of follow-up, surgical outcomes were evaluated based on fistula relapse and other complications. After six months, relapse occurred in only one patient, a six-year-old boy with a single 4-mm distal opening, who had undergone no previous fistula repairs. Therefore, in 97.5% of the cases, relapse was non-existent. Other complications, such as urethral stenosis, intraurethral obstruction, and epidermal inclusion cysts, were not seen in the other patients during the six-month follow-up period. This repair method, which is simple, rapid, and easily learned, is highly applicable, with a high success rate for the closure of UCFs measuring up to 4 mm in any location.

  19. Thinking Inside the Box: Simple Methods to Evaluate Complex Treatments

    Directory of Open Access Journals (Sweden)

    J. Michael Menke

    2011-10-01

    Full Text Available We risk ignoring cheaper and safer medical treatments because they cannot be patented, lack profit potential, require too much patient-contact time, or do not have scientific results. Novel medical treatments may be difficult to evaluate for a variety of reasons such as patient selection bias, the effect of the package of care, or the lack of identifying the active elements of treatment. Whole Systems Research (WSR is an approach designed to assess the performance of complete packages of clinical management. While the WSR method is compelling, there is no standard procedure for WSR, and its implementation may be intimidating. The truth is that WSR methodological tools are neither new nor complicated. There are two sequential steps, or boxes, that guide WSR methodology: establishing system predictability, followed by an audit of system element effectiveness. We describe the implementation of WSR with a particular attention to threats to validity (Shadish, Cook, & Campbell, 2002; Shadish & Heinsman, 1997. DOI: 10.2458/azu_jmmss.v2i1.12365

  20. A simple method for generating exactly solvable quantum mechanical potentials

    CERN Document Server

    Williams, B W

    1993-01-01

    A simple transformation method permitting the generation of exactly solvable quantum mechanical potentials from special functions solving second-order differential equations is reviewed. This method is applied to Gegenbauer polynomials to generate an attractive radial potential. The relationship of this method to the determination of supersymmetric quantum mechanical superpotentials is discussed, and the superpotential for the radial potential is also derived. (author)

  1. LandScape: a simple method to aggregate p--Values and other stochastic variables without a priori grouping

    DEFF Research Database (Denmark)

    Wiuf, Carsten; Pallesen, Jonatan; Foldager, Leslie

    2016-01-01

    variables without assuming a priori defined groups. We provide different ways to evaluate the significance of the aggregated variables based on theoretical considerations and resampling techniques, and show that under certain assumptions the FWER is controlled in the strong sense. Validity of the method...... and the results might depend on the chosen criteria. Methods that summarize, or aggregate, test statistics or p-values, without relying on a priori criteria, are therefore desirable. We present a simple method to aggregate a sequence of stochastic variables, such as test statistics or p-values, into fewer...

  2. New simple evaluation method of the monosyllable /sa/ using a psychoacoustic system in maxillectomy patients.

    Science.gov (United States)

    Chowdhury, Nafees Uddin; Otomaru, Takafumi; Murase, Mai; Inohara, Ken; Hattori, Mariko; Sumita, Yuka I; Taniguchi, Hisashi

    2011-01-01

    An objective assessment of speech would benefit the prosthetic rehabilitation of maxillectomy patients. This study aimed to establish a simple, objective evaluation of monosyllable /sa/ utterances in maxillectomy patients by using a psychoacoustic system typically used in industry. This study comprised two experiments. Experiment 1 involved analysis of the psychoacoustic parameters (loudness, sharpness and roughness) in monosyllable /sa/ utterances by 18 healthy subjects (9 males, 9 females). The utterances were recorded in a sound-treated room. The coefficient of variation (CV) for each parameter was compared to identify the most suitable parameter for objective evaluation of speech. Experiment 2 involved analysis of /sa/ utterances by 18 maxillectomy patients (9 males, 9 females) with and without prosthesis, and comparisons of the psychoacoustic data between the healthy subjects and maxillectomy patients without prosthesis, between the maxillectomy patients with and without prosthesis, and between the healthy subjects and maxillectomy patients with prosthesis. The CV for sharpness was the lowest among the three psychoacoustic parameters in both the healthy males and females. There were significant differences in the sharpness of /sa/ between the healthy subjects and the maxillectomy patients without prosthesis (but not with prosthesis), and between the maxillectomy patients with and without prosthesis. We found that the psychoacoustic parameters typically adopted in industrial research could also be applied to evaluate the psychoacoustics of the monosyllable /sa/ utterance, and distinguished the monosyllable /sa/ in maxillectomy patients with an obturator from that without an obturator using the system. Copyright © 2010 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  3. Simple statistical methods for software engineering data and patterns

    CERN Document Server

    Pandian, C Ravindranath

    2015-01-01

    Although there are countless books on statistics, few are dedicated to the application of statistical methods to software engineering. Simple Statistical Methods for Software Engineering: Data and Patterns fills that void. Instead of delving into overly complex statistics, the book details simpler solutions that are just as effective and connect with the intuition of problem solvers.Sharing valuable insights into software engineering problems and solutions, the book not only explains the required statistical methods, but also provides many examples, review questions, and case studies that prov

  4. UM EXPERIMENTO RELATIVAMENTE SIMPLES E RÁPIDO DE CINÉTICA DA DESTRUIÇÃO DE LEVEDURAS PELO CALOR A RELATIVITY SIMPLE AND RAPID METHOD OF THERMAL DESTRUCTION OF YEATS CELLS

    Directory of Open Access Journals (Sweden)

    Walter BORZANI

    1998-10-01

    Full Text Available Descreve-se um experimento simples e rápido que permite calcular a constante de velocidade de destruição térmica de leveduras (fermento prensado a uma temperatura na faixa de 55ºC a 60°C, e estudar a influência de fatores nessa constante.A simple and rapid method that permits to evaluate the rate constant of thermal destruction of yeast cells (pressed yeast at a temperature between 55ºC and 60ºC, and also to study the influence of experimental conditions on the above rate constant, is described.

  5. Method of levelized discounted costs applied in economic evaluation of nuclear power plant project

    International Nuclear Information System (INIS)

    Tian Li; Wang Yongqing; Liu Jingquan; Guo Jilin; Liu Wei

    2000-01-01

    The main methods of economic evaluation of bid which are in common use are introduced. The characteristics of levelized discounted cost method and its application are presented. The method of levelized discounted cost is applied to the cost calculation of a 200 MW nuclear heating reactor economic evaluation. The results indicate that the method of levelized discounted costs is simple, feasible and which is considered most suitable for the economic evaluation of various case. The method is suggested which is used in the national economic evaluation

  6. The modified simple equation method for solving some fractional ...

    Indian Academy of Sciences (India)

    ... and processes in various areas of natural science. Thus, many effective and powerful methods have been established and improved. In this study, we establish exact solutions of the time fractional biological population model equation and nonlinearfractional Klein–Gordon equation by using the modified simple equation ...

  7. Simple and convenient method for culturing anaerobic bacteria.

    OpenAIRE

    Behbehani, M J; Jordan, H V; Santoro, D L

    1982-01-01

    A simple and convenient method for culturing anaerobic bacteria is described. Cultures can be grown in commercially available flasks normally used for preparation of sterile external solutions. A special disposable rubber flask closure maintains anaerobic conditions in the flask after autoclaving. Growth of a variety of anaerobic oral bacteria was comparable to that obtained after anaerobic incubation of broth cultures in Brewer Anaerobic Jars.

  8. A simple method for one-loop renormalization in curved space-time

    Energy Technology Data Exchange (ETDEWEB)

    Markkanen, Tommi [Helsinki Institute of Physics and Department of Physics, P.O. Box 64, FI-00014, University of Helsinki (Finland); Tranberg, Anders, E-mail: tommi.markkanen@helsinki.fi, E-mail: anders.tranberg@uis.no [Niels Bohr International Academy and Discovery Center, Niels Bohr Institute, Blegdamsvej 17, 2100 Copenhagen (Denmark)

    2013-08-01

    We present a simple method for deriving the renormalization counterterms from the components of the energy-momentum tensor in curved space-time. This method allows control over the finite parts of the counterterms and provides explicit expressions for each term separately. As an example, the method is used for the self-interacting scalar field in a Friedmann-Robertson-Walker metric in the adiabatic approximation, where we calculate the renormalized equation of motion for the field and the renormalized components of the energy-momentum tensor to fourth adiabatic order while including interactions to one-loop order. Within this formalism the trace anomaly, including contributions from interactions, is shown to have a simple derivation. We compare our results to those obtained by two standard methods, finding agreement with the Schwinger-DeWitt expansion but disagreement with adiabatic subtractions for interacting theories.

  9. A simple method for DNA isolation from Xanthomonas spp.

    Directory of Open Access Journals (Sweden)

    Gomes Luiz Humberto

    2000-01-01

    Full Text Available A simple DNA isolation method was developed with routine chemicals that yields high quality and integrity preparations when compared to some of the most well known protocols. The method described does not require the use of lysing enzymes, water bath and the DNA was obtained within 40 minutes The amount of nucleic acid extracted (measured in terms of absorbancy at 260 nm from strains of Xanthomonas spp., Pseudomonas spp. and Erwinia spp. was two to five times higher than that of the most commonly used method.

  10. Simple estimating method of damages of concrete gravity dam based on linear dynamic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Sasaki, T.; Kanenawa, K.; Yamaguchi, Y. [Public Works Research Institute, Tsukuba, Ibaraki (Japan). Hydraulic Engineering Research Group

    2004-07-01

    Due to the occurrence of large earthquakes like the Kobe Earthquake in 1995, there is a strong need to verify seismic resistance of dams against much larger earthquake motions than those considered in the present design standard in Japan. Problems exist in using nonlinear analysis to evaluate the safety of dams including: that the influence which the set material properties have on the results of nonlinear analysis is large, and that the results of nonlinear analysis differ greatly according to the damage estimation models or analysis programs. This paper reports the evaluation indices based on a linear dynamic analysis method and the characteristics of the progress of cracks in concrete gravity dams with different shapes using a nonlinear dynamic analysis method. The study concludes that if simple linear dynamic analysis is appropriately conducted to estimate tensile stress at potential locations of initiating cracks, the damage due to cracks would be predicted roughly. 4 refs., 1 tab., 13 figs.

  11. Lowest-order constrained variational method for simple many-fermion systems

    International Nuclear Information System (INIS)

    Alexandrov, I.; Moszkowski, S.A.; Wong, C.W.

    1975-01-01

    The authors study the potential energy of many-fermion systems calculated by the lowest-order constrained variational (LOCV) method of Pandharipande. Two simple two-body interactions are used. For a simple hard-core potential in a dilute Fermi gas, they find that the Huang-Yang exclusion correction can be used to determine a healing distance. The result is close to the older Pandharipande prescription for the healing distance. For a hard core plus attractive exponential potential, the LOCV result agrees closely with the lowest-order separation method of Moszkowski and Scott. They find that the LOCV result has a shallow minimum as a function of the healing distance at the Moszkowski-Scott separation distance. The significance of the absence of a Brueckner dispersion correction in the LOCV result is discussed. (Auth.)

  12. Continuously variable rating: a new, simple and logical procedure to evaluate original scientific publications

    Directory of Open Access Journals (Sweden)

    Mauricio Rocha e Silva

    2011-01-01

    Full Text Available OBJECTIVE: Impact Factors (IF are widely used surrogates to evaluate single articles, in spite of known shortcomings imposed by cite distribution skewness. We quantify this asymmetry and propose a simple computer-based procedure for evaluating individual articles. METHOD: (a Analysis of symmetry. Journals clustered around nine Impact Factor points were selected from the medical ‘‘Subject Categories’’ in Journal Citation Reports 2010. Citable items published in 2008 were retrieved and ranked by granted citations over the Jan/2008 - Jun/2011 period. Frequency distribution of cites, normalized cumulative cites and absolute cites/decile were determined for each journal cluster. (b Positive Predictive Value. Three arbitrarily established evaluation classes were generated: LOW (1.33.9. Positive Predictive Value for journal clusters within each class range was estimated. (c Continuously Variable Rating. An alternative evaluation procedure is proposed to allow the rating of individually published articles in comparison to all articles published in the same journal within the same year of publication. The general guiding lines for the construction of a totally dedicated software program are delineated. RESULTS AND CONCLUSIONS: Skewness followed the Pareto Distribution for (1simple computer based procedure capable of accurately providing a valid rating for each article within the journal and time frame in which it was published.

  13. A simple method to measure cell viability in proliferation and cytotoxicity assays

    Directory of Open Access Journals (Sweden)

    Ricardo Carneiro Borra

    2009-09-01

    Full Text Available Resazurin dye has been broadly used as indicator of cell viability in several types of assays for evaluation of the biocompatibility of medical and dental materials. Mitochondrial enzymes, as carriers of diaphorase activities, are probably responsible for the transference of electrons from NADPH + H+ to resazurin, which is reduced to resorufin. The level of reduction can be quantified by spectrophotometers since resazurin exhibits an absorption peak at 600 ηm and resorufin at 570 ηm wavelengths. However, the requirement of a spectrophotometer and specific filters for the quantification could be a barrier to many laboratories. Digital cameras containing red, green and blue filters, which allow the capture of red (600 to 700 ηm and green (500 to 600 ηm light wavelengths in ranges bordering on resazurin and resorufin absorption bands, could be used as an alternative method for the assessment of resazurin and resorufin concentrations. Thus, our aim was to develop a simple, cheap and precise method based on a digital CCD camera to measure the reduction of resazurin. We compared the capability of the CCD-based method to distinguish different concentrations of L929 and normal Human buccal fibroblast cell lines with that of a conventional microplate reader. The correlation was analyzed through the Pearson coefficient. The results showed a strong association between the measurements of the method developed here and those made with the microplate reader (r² = 0.996; p < 0.01 and with the cellular concentrations (r² = 0.965; p < 0.01. We concluded that the developed Colorimetric Quantification System based on CCD Images allowed rapid assessment of the cultured cell concentrations with simple equipment at a reduced cost.

  14. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias Guldberg

     We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtit...... available. In conclusion, we have set up a simple solution for the continuous validation of automated liquid handlers used for accredited work. The method is cheap, simple and easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....... We have implemented a simple method for validation and verification of the performance of pipettes mounted on automated liquid handlers as necessary for laboratories accredited under ISO 17025. An 8-step serial dilution of Orange G was prepared in quadruplicates in a flat bottom 96-well microtiter...

  15. A simple immunoblotting method after separation of proteins in agarose gel

    DEFF Research Database (Denmark)

    Koch, C; Skjødt, K; Laursen, I

    1985-01-01

    A simple and sensitive method for immunoblotting of proteins after separation in agarose gels is described. It involves transfer of proteins onto nitrocellulose paper simply by diffusion through pressure, a transfer which only takes about 10 min. By this method we have demonstrated the existence ...

  16. A simple method of fitting ill-conditioned polynomials to data

    International Nuclear Information System (INIS)

    Buckler, A.N.; Lawrence, J.

    1979-04-01

    A very simple transformation of the independent variable x is shown to cure the ill-conditioning when some polynomial series are fitted to given Y values. Numerical examples are given to illustrate the power of the method. (author)

  17. Simple method of testing polymer leaching from thermoplastic sheets used for clear aligner

    Directory of Open Access Journals (Sweden)

    Shuvana Altaf Ansari

    2014-01-01

    Full Text Available Objective: With the increasing popularity of clear aligners, newer materials are introduced in the form of thermoplastic sheets. Long-term studies testing the biocompatibility of these sheets are not available. The purpose of this study is to provide a simple, yet effective method to evaluate their leaching potential. Materials and Methods: Using the oxidation reduction reaction taking place in the presence of two different concentrations of potassium permanganate, five different samples were tested. The sequence of colour change from purple to red to brown to yellow to clear was used to determine the amount of leaching. This is the result of a stoichiometric relation between the oxidizing agent and the reducing sample. Color changes were observed through naked eyes over a period of 24 h. Photographs were taken at 15 min, 8 h and 24 h using D-SLR1000 Canon camera. Photos were evaluated separately. Result: Diluted solution showed faster change in color, due to the lesser amount of reagent. 3A Medes (Korea was the first to leach, followed by CA (Scheu, Germany EVA (Endent Private Limited, Delhi, India, Ultradent (United States and Avac R (Jaypee, Kerela, India. Conclusion: "Do it yourself" test is a repeatable and reproducible method that can be modified and used in clinical practice as a chair side method.

  18. The simple modelling method for storm- and grey-water quality ...

    African Journals Online (AJOL)

    The simple modelling method for storm- and grey-water quality management applied to Alexandra settlement. ... objectives optimally consist of educational programmes, erosion and sediment control, street sweeping, removal of sanitation system overflows, impervious cover reduction, downspout disconnections, removal of ...

  19. A Simple Method for Identifying the Acromioclavicular Joint During Arthroscopic Procedures

    OpenAIRE

    Javed, Saqib; Heasley, Richard; Ravenscroft, Matt

    2013-01-01

    Arthroscopic acromioclavicular joint excision is performed via an anterior portal and is technically demanding. We present a simple method for identifying the acromioclavicular joint during arthroscopic procedures.

  20. A simple method for quantitative evaluation of the missing area of the anterior glenoid in anterior instability of the glenohumeral joint

    Energy Technology Data Exchange (ETDEWEB)

    Barchilon, Vidal S. [Sapir Medical Center, Department of Orthopedic Surgery, Shoulder Service, Kfar-Saba (Israel); Kotz, Eugene [Sapir Medical Center, Department of Imaging, Kfar-Saba (Israel); Barchilon Ben-Av, Mercedes [Achva College of Education, Department of Mathematics, MP Shikmim (Israel); Glazer, Ernesto [Rabin Medical Center, Department of Imaging, Petah Tikva (Israel); Nyska, Meir [Sapir Medical Center, Department of Orthopedic Surgery, Kfar-Saba (Israel)

    2008-08-15

    The objective of this study was to describe and validate a simple method to quantitatively calculate the missing area of the anterior part of the glenoid in anterior glenohumeral instability. The calculations were developed from three-dimensional (3D)-reconstructed computerized tomography en face images of the glenoid with 'subtraction' of the humeral head in 13 consecutive cases with known anterior glenohumeral joint instability diagnosed by history and clinical examination. The inferior portion of the glenoid was approximated to a true circle whose center was determined by means of a femoral head gauge. The eroded anterior area was calculated as the ratio between the depth (a perpendicular line from the center of the circle to the eroded edge of the anterior glenoid) and the radius of the inferior glenoid circle. This data was then compared to the results obtained by two additional different methods: direct computerized measurements of the missing area and direct computerized measurement of the ratio between the radius and depth, on two dimensional computed tomography (CT) en face view reconstructions of the glenoid. We provide a function that correlates the ratio between depth and radius of the inferior glenoid circle and the area of the missing anterior glenoid. The results obtained by three different methods were comparable. Simple trigonometric calculations showed that a 5% area defect corresponds to 0.8 (12.5%) of the radius of the inferior glenoid, while a 20% area defect corresponds to 0.5 (50%) of the same radius. Using this simple method and the function provided, the eroded area of the anterior part of the glenoid in anterior glenohumeral instability can be calculated preoperatively using a 3D CT reconstruction of the glenoid with 'subtraction' of the humeral head, obviating the need for sophisticated software to obtain this critical information for preoperative decision making. (orig.)

  1. A simple method for estimating thermal response of building ...

    African Journals Online (AJOL)

    This paper develops a simple method for estimating the thermal response of building materials in the tropical climatic zone using the basic heat equation. The efficacy of the developed model has been tested with data from three West African cities, namely Kano (lat. 12.1 ºN) Nigeria, Ibadan (lat. 7.4 ºN) Nigeria and Cotonou ...

  2. Fill rate estimation in periodic review policies with lost sales using simple methods

    Energy Technology Data Exchange (ETDEWEB)

    Cardós, M.; Guijarro Tarradellas, E.; Babiloni Griñón, E.

    2016-07-01

    Purpose: The exact estimation of the fill rate in the lost sales case is complex and time consuming. However, simple and suitable methods are needed for its estimation so that inventory managers could use them. Design/methodology/approach: Instead of trying to compute the fill rate in one step, this paper focuses first on estimating the probabilities of different on-hand stock levels so that the fill rate is computed later. Findings: As a result, the performance of a novel proposed method overcomes the other methods and is relatively simple to compute. Originality/value: Existing methods for estimating stock levels are examined, new procedures are proposed and their performance is assessed.

  3. A Simple DTC-SVM method for Matrix Converter Drives Using a Deadbeat Scheme

    DEFF Research Database (Denmark)

    Lee, Kyo-Beum; Blaabjerg, Frede; Lee, Kwang-Won

    2005-01-01

    In this paper, a simple direct torque control (DTC) method for sensorless matrix converter drives is proposed, which is characterized by a simple structure, minimal torque ripple and unity input power factor. Also a good sensorless speed-control performance in the low speed operation is obtained,...

  4. 12 CFR 334.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... STATEMENTS OF GENERAL POLICY FAIR CREDIT REPORTING Affiliate Marketing § 334.25 Reasonable and simple methods... or processed at an Internet Web site, if the consumer agrees to the electronic delivery of... opt-out under the Act, and the affiliate marketing opt-out under the Act, by a single method, such as...

  5. S-MRI score: A simple method for assessing bone marrow involvement in Gaucher disease

    International Nuclear Information System (INIS)

    Roca, M.; Mota, J.; Alfonso, P.; Pocovi, M.; Giraldo, P.

    2007-01-01

    Semi quantitative MRI is a very useful procedure for evaluating the bone marrow burden (BMB) in Gaucher disease (GD). Score systems have been applied to obtain a parameter for evaluating the severity of bone disease. Our purpose was to test a simple, reproducible and accurate score to evaluate bone marrow involvement in GD patients. MRI was performed in spine, pelvis and femora at diagnosis in 54 adult GD1 patients, 61.1% of whom were female. Three MRI patterns and punctuation in each location were defined: normal, 0; non-homogeneous infiltration subtypes reticular, 1; mottled, 2; diffuse, 3; and homogeneous infiltration, 4. This score was called Spanish-MRI (S-MRI). Two independent observers applied the S-MRI and bone marrow burden score and compared the differences using the non-parametric Mann-Whitney test. Correlation rank test was calculated. In 46 patients (85.2%), bone involvement was observed. Thirty-nine (72.3%) had their spine affected, 35 (64.8%) pelvis and 33 (61.2%) femora. Fourteen patients had bone infarcts, 14 avascular necrosis, 2 vertebral fractures and 2 bone crises. Correlation analysis between S-MRI and BMB was (r 2 = .675; p = .0001). No evidence of correlation was observed between CT activity and S-MRI nor between CT activity and BMB. We have found a relationship between genotype and bone infiltration according to S-MRI site and complications. S-MRI is a simple method that provides useful information to evaluate bone infiltration and detect silent complications. Our results correlated with the BMB score but offer higher sensitivity, specificity and accuracy for classifying the extent of bone disease

  6. S-MRI score: A simple method for assessing bone marrow involvement in Gaucher disease

    Energy Technology Data Exchange (ETDEWEB)

    Roca, M. [Radiology (Magnetic Resonance) Instituto Aragones de Ciencias de la Salud (I-CS), Zaragoza (Spain); Mota, J. [Diagnostic Imaging Department, Medimagen, Barcelona (Spain); Alfonso, P. [Radiology (Magnetic Resonance) Instituto Aragones de Ciencias de la Salud (I-CS), Zaragoza (Spain); Pocovi, M. [Biochemistry and Cellular and Molecular Biology Department, Zaragoza University (Spain); Giraldo, P. [Haematology Department, Miguel Servet University Hospital, 50009 Zaragoza (Spain)]. E-mail: pgiraldo@salud.aragon.es

    2007-04-15

    Semi quantitative MRI is a very useful procedure for evaluating the bone marrow burden (BMB) in Gaucher disease (GD). Score systems have been applied to obtain a parameter for evaluating the severity of bone disease. Our purpose was to test a simple, reproducible and accurate score to evaluate bone marrow involvement in GD patients. MRI was performed in spine, pelvis and femora at diagnosis in 54 adult GD1 patients, 61.1% of whom were female. Three MRI patterns and punctuation in each location were defined: normal, 0; non-homogeneous infiltration subtypes reticular, 1; mottled, 2; diffuse, 3; and homogeneous infiltration, 4. This score was called Spanish-MRI (S-MRI). Two independent observers applied the S-MRI and bone marrow burden score and compared the differences using the non-parametric Mann-Whitney test. Correlation rank test was calculated. In 46 patients (85.2%), bone involvement was observed. Thirty-nine (72.3%) had their spine affected, 35 (64.8%) pelvis and 33 (61.2%) femora. Fourteen patients had bone infarcts, 14 avascular necrosis, 2 vertebral fractures and 2 bone crises. Correlation analysis between S-MRI and BMB was (r {sup 2} = .675; p = .0001). No evidence of correlation was observed between CT activity and S-MRI nor between CT activity and BMB. We have found a relationship between genotype and bone infiltration according to S-MRI site and complications. S-MRI is a simple method that provides useful information to evaluate bone infiltration and detect silent complications. Our results correlated with the BMB score but offer higher sensitivity, specificity and accuracy for classifying the extent of bone disease.

  7. The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures

    Science.gov (United States)

    Stephenson, W. Kirk

    2009-01-01

    A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes. (Contains 4 notes.)

  8. Method of Factor Extraction and Simple Structure of Data from Diverse Scientific Areas.

    Science.gov (United States)

    Thorndike, Robert M.

    To study the applicability of simple structure logic for factorial data from scientific disciplines outside psychology, four correlation matrices from each of six scientific areas were factor analyzed by five factoring methods. Resulting factor matrices were compared on two objective criteria of simple structure before and after rotation.…

  9. A Simple Microsoft Excel Method to Predict Antibiotic Outbreaks and Underutilization.

    Science.gov (United States)

    Miglis, Cristina; Rhodes, Nathaniel J; Avedissian, Sean N; Zembower, Teresa R; Postelnick, Michael; Wunderink, Richard G; Sutton, Sarah H; Scheetz, Marc H

    2017-07-01

    Benchmarking strategies are needed to promote the appropriate use of antibiotics. We have adapted a simple regressive method in Microsoft Excel that is easily implementable and creates predictive indices. This method trends consumption over time and can identify periods of over- and underuse at the hospital level. Infect Control Hosp Epidemiol 2017;38:860-862.

  10. Method of evaluation of diagnostics reference levels in computerized tomography

    International Nuclear Information System (INIS)

    Vega, Walter Flores

    1999-04-01

    Computerized tomography is a complex technique with several selectable exposition parameters delivering high doses to the patient. In this work it was developed a simple methodology to evaluate diagnostic reference levels in computerized tomography, using the concept of Multiple Scan Average Dose (MSAD), recently adopted by the Health Ministry. For evaluation of the MSAD, a dose distribution was obtained through a measured dose profile on the axial axis of a water phantom with thermoluminescence dosemeters, TLD-100, for different exam technique. The MSAD was evaluated hrough two distinct methods. First, it was evaluated by the integration of the dose profile of a single slice and, second, obtained by the integration on central slice of the profile of several slices. The latter is in of accordance with the ionization chamber method, suggesting to be the most practical method of dose evaluation to be applied in the diagnostic reference level assessment routine for CT, using TLDs. (author)

  11. Comparison of six simple methods for extracting ribosomal and mitochondrial DNA from Toxocara and Toxascaris nematodes.

    Science.gov (United States)

    Mikaeili, F; Kia, E B; Sharbatkhori, M; Sharifdini, M; Jalalizand, N; Heidari, Z; Zarei, Z; Stensvold, C R; Mirhendi, H

    2013-06-01

    Six simple methods for extraction of ribosomal and mitochondrial DNA from Toxocara canis, Toxocara cati and Toxascaris leonina were compared by evaluating the presence, appearance and intensity of PCR products visualized on agarose gels and amplified from DNA extracted by each of the methods. For each species, two isolates were obtained from the intestines of their respective hosts: T. canis and T. leonina from dogs, and T. cati from cats. For all isolates, total DNA was extracted using six different methods, including grinding, boiling, crushing, beating, freeze-thawing and the use of a commercial kit. To evaluate the efficacy of each method, the internal transcribed spacer (ITS) region and the cytochrome c oxidase subunit 1 (cox1) gene were chosen as representative markers for ribosomal and mitochondrial DNA, respectively. Among the six DNA extraction methods, the beating method was the most cost effective for all three species, followed by the commercial kit. Both methods produced high intensity bands on agarose gels and were characterized by no or minimal smear formation, depending on gene target; however, beating was less expensive. We therefore recommend the beating method for studies where costs need to be kept at low levels. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Quantitative Evaluation of Heavy Duty Machine Tools Remanufacturing Based on Modified Catastrophe Progression Method

    Science.gov (United States)

    shunhe, Li; jianhua, Rao; lin, Gui; weimin, Zhang; degang, Liu

    2017-11-01

    The result of remanufacturing evaluation is the basis for judging whether the heavy duty machine tool can remanufacture in the EOL stage of the machine tool lifecycle management.The objectivity and accuracy of evaluation is the key to the evaluation method.In this paper, the catastrophe progression method is introduced into the quantitative evaluation of heavy duty machine tools’ remanufacturing,and the results are modified by the comprehensive adjustment method,which makes the evaluation results accord with the standard of human conventional thinking.Using the catastrophe progression method to establish the heavy duty machine tools’ quantitative evaluation model,to evaluate the retired TK6916 type CNC floor milling-boring machine’s remanufacturing.The evaluation process is simple,high quantification,the result is objective.

  13. A Simple Method for Dynamic Scheduling in a Heterogeneous Computing System

    OpenAIRE

    Žumer, Viljem; Brest, Janez

    2002-01-01

    A simple method for the dynamic scheduling on a heterogeneous computing system is proposed in this paper. It was implemented to minimize the parallel program execution time. The proposed method decomposes the program workload into computationally homogeneous subtasks, which may be of the different size, depending on the current load of each machine in a heterogeneous computing system.

  14. Development of a Simple and Effective Bioassay Method to Evaluate Resistance of Watermelon Plants to Fusarium oxysporum f. sp. niveum

    Directory of Open Access Journals (Sweden)

    Eun Ju Jo

    2017-06-01

    Full Text Available Root-dipping inoculation method has been widely used to determine the resistance of watermelon to Fusarium oxysporum f. sp. niveum causing Fusarium wilt. Although this method leads to the precise results of plant disease responses, more rapid and efficient assay methods have been still required because the root-dipping inoculation method is labor-intensive and time-consuming. In this study, we established a simple and effective bioassay method based on the comparison of various inoculation methods and growth conditions. To develop the system, the occurrence of Fusarium wilt on four resistant and susceptible cultivars was investigated by four different inoculation methods, root-dipping, scalpel, tip and soil-drenching methods. Of these inoculation methods, scalpel method resulted in clear plant disease resistance responses with the simplicity. With the use of scalpel method, we also explored the disease development of the cultivars depending on inoculum concentration, growth stage of seedlings, and incubation temperature after inoculation. Furthermore, we found that the resistance degrees of 23 cultivars derived by scalpel inoculation method were similar to the results by root-dipping method established previously.

  15. Double-lock technique: a simple method to secure abdominal wall closure

    International Nuclear Information System (INIS)

    Jategaonkar, P.A.; Yadav, S.P.

    2013-01-01

    Secure closure of a laparotomy incision remains an important aspect of any abdominal operation with the aim to avoid the postoperative morbidity and hasten the patient's recovery. Depending on the operator's preference and experience, it may be done by the continuous or the interrupted methods either using a non-absorbable or delayed-absorbable suture. We describe a simple, secure and quick technique of abdominal wall closure which involves continuous suture inter-locked doubly after every third bite. This simple and easy to use mass closure technique can be easily mastered by any member of the surgical team and does not need any assistant. It amalgamates the advantages of both, the continuous and the interrupted methods of closures. To our knowledge, such a technique has not been reported in the literature. (author)

  16. Some new, simple and efficient stereological methods and their use in pathological research and diagnosis

    DEFF Research Database (Denmark)

    Gundersen, H J; Bendtsen, T F; Korbo, L

    1988-01-01

    Stereology is a set of simple and efficient methods for quantitation of three-dimensional microscopic structures which is specifically tuned to provide reliable data from sections. Within the last few years, a number of new methods has been developed which are of special interest to pathologists...... are invariably simple and easy....

  17. Process control and optimization with simple interval calculation method

    DEFF Research Database (Denmark)

    Pomerantsev, A.; Rodionova, O.; Høskuldsson, Agnar

    2006-01-01

    for the quality improvement in the course of production. The latter is an active quality optimization, which takes into account the actual history of the process. The advocate approach is allied to the conventional method of multivariate statistical process control (MSPC) as it also employs the historical process......Methods of process control and optimization are presented and illustrated with a real world example. The optimization methods are based on the PLS block modeling as well as on the simple interval calculation methods of interval prediction and object status classification. It is proposed to employ...... the series of expanding PLS/SIC models in order to support the on-line process improvements. This method helps to predict the effect of planned actions on the product quality and thus enables passive quality control. We have also considered an optimization approach that proposes the correcting actions...

  18. Simple method for quick estimation of aquifer hydrogeological parameters

    Science.gov (United States)

    Ma, C.; Li, Y. Y.

    2017-08-01

    Development of simple and accurate methods to determine the aquifer hydrogeological parameters was of importance for groundwater resources assessment and management. Aiming at the present issue of estimating aquifer parameters based on some data of the unsteady pumping test, a fitting function of Theis well function was proposed using fitting optimization method and then a unitary linear regression equation was established. The aquifer parameters could be obtained by solving coefficients of the regression equation. The application of the proposed method was illustrated, using two published data sets. By the error statistics and analysis on the pumping drawdown, it showed that the method proposed in this paper yielded quick and accurate estimates of the aquifer parameters. The proposed method could reliably identify the aquifer parameters from long distance observed drawdowns and early drawdowns. It was hoped that the proposed method in this paper would be helpful for practicing hydrogeologists and hydrologists.

  19. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin

    DEFF Research Database (Denmark)

    Thoisen, Christina Vinum; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive...... freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. Filters with the cryptophyte were frozen (−80 °C) and added phosphate buffer for extraction at 4 °C...... followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes. •Minimal usage of equipment and chemicals, and low labor costs. •Applicable for industrial and biological purposes....

  20. Uniting Evidence-Based Evaluation with the ACGME Plastic Surgery Milestones: A Simple and Reliable Assessment of Resident Operative Performance.

    Science.gov (United States)

    Kobraei, Edward M; Bohnen, Jordan D; George, Brian C; Mullen, John T; Lillemoe, Keith D; Austen, William G; Liao, Eric C

    2016-08-01

    Milestones evaluations in plastic surgery reflect a shift toward competency-based training but have created a number of challenges. The authors have incorporated the smartphone application evaluation tool, System for Improving and Measuring Procedural Learning (SIMPL), that was recently developed by a multi-institutional research collaborative. In this pilot study, the authors hypothesize that SIMPL can improve resident evaluation and also collect granular performance data to simplify compliance with the plastic surgery Milestones. SIMPL was prospectively piloted with a plastic surgery resident and faculty surgeon at Massachusetts General Hospital in this institutional review board-approved study. The study period was a 2-month interval corresponding to the resident's rotation. The resident-faculty combination performed 20 cases together. All cases were evaluated with SIMPL. SIMPL evaluations uniformly took under 1 minute to submit. The average time to completed evaluation from surgery completion was 5 hours (technology will support a shared vocabulary between residents and faculty to enhance intraoperative education.

  1. A New and Simple Method for Crosstalk Estimation in Homogeneous Trench-Assisted Multi-Core Fibers

    DEFF Research Database (Denmark)

    Ye, Feihong; Tu, Jiajing; Saitoh, Kunimasa

    2014-01-01

    A new and simple method for inter-core crosstalk estimation in homogeneous trench-assisted multi-core fibers is presented. The crosstalk calculated by this method agrees well with experimental measurement data for two kinds of fabricated 12-core fibers.......A new and simple method for inter-core crosstalk estimation in homogeneous trench-assisted multi-core fibers is presented. The crosstalk calculated by this method agrees well with experimental measurement data for two kinds of fabricated 12-core fibers....

  2. Simple method to generate and fabricate stochastic porous scaffolds

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Nan, E-mail: y79nzw@163.com; Gao, Lilan; Zhou, Kuntao

    2015-11-01

    Considerable effort has been made to generate regular porous structures (RPSs) using function-based methods, although little effort has been made for constructing stochastic porous structures (SPSs) using the same methods. In this short communication, we propose a straightforward method for SPS construction that is simple in terms of methodology and the operations used. Using our method, we can obtain a SPS with functionally graded, heterogeneous and interconnected pores, target pore size and porosity distributions, which are useful for applications in tissue engineering. The resulting SPS models can be directly fabricated using additive manufacturing (AM) techniques. - Highlights: • Random porous structures are constructed based on their regular counterparts. • Functionally graded random pores can be constructed easily. • The scaffolds can be directly fabricated using additive manufacturing techniques.

  3. A simple method to adapt time sampling of the analog signal

    International Nuclear Information System (INIS)

    Kalinin, Yu.G.; Martyanov, I.S.; Sadykov, Kh.; Zastrozhnova, N.N.

    2004-01-01

    In this paper we briefly describe the time sampling method, which is adapted to the speed of the signal change. Principally, this method is based on a simple idea--the combination of discrete integration with differentiation of the analog signal. This method can be used in nuclear electronics research into the characteristics of detectors and the shape of the pulse signal, pulse and transitive characteristics of inertial systems of processing of signals, etc

  4. Simple method for correct enumeration of Staphylococcus aureus

    DEFF Research Database (Denmark)

    Haaber, J.; Cohn, M. T.; Petersen, A.

    2016-01-01

    culture. When grown in such liquid cultures, the human pathogen Staphylococcus aureus is characterized by its aggregation of single cells into clusters of variable size. Here, we show that aggregation during growth in the laboratory standard medium tryptic soy broth (TSB) is common among clinical...... and laboratory S. aureus isolates and that aggregation may introduce significant bias when applying standard enumeration methods on S. aureus growing in laboratory batch cultures. We provide a simple and efficient sonication procedure, which can be applied prior to optical density measurements to give...

  5. Simple Screening Methods for Drought and Heat Tolerance in Cowpea

    International Nuclear Information System (INIS)

    Singh, B. B.

    2000-10-01

    Success in breeding for drought tolerance has not been as pronounced as for other traits. This is partly due to lack of simple, cheap and reliable screening methods to select drought tolerant plants/progenies from the segregating populations and partly due to complexity of factors involved in drought tolerance. Measuring drought tolerance through physiological parameters is expensive, time consuming and difficult to use for screening large numbers of lines and segregating populations. Since several factors/mechanisms (in shoot and root) operate independently and/or jointly to enable plants to cope with drought stress, drought tolerance appears as a complex trait. However, if these factors/mechanisms can be separated and studied individually, the components leading to drought tolerance will appear less complex and may be easy to manipulate by breeders. We have developed a simple box screening method for shoot drought tolerance in cowpea, which eliminates the effects of roots and permits non-destructive visual identification of shoot dehydration tolerance. We have also developed a 'root-box pin-board' method to study two dimensional root architecture of individual plants. Using these methods, we have identified two mechanisms of shoot drought tolerance in cowpea which are controlled by single dominant genes and major difference for root architecture among cowpea varieties. Combining deep and dense root system with shoot dehydration tolerance results into highly drought tolerant plants

  6. A simple and efficient method for isolating small RNAs from different plant species

    Directory of Open Access Journals (Sweden)

    de Folter Stefan

    2011-02-01

    Full Text Available Abstract Background Small RNAs emerged over the last decade as key regulators in diverse biological processes in eukaryotic organisms. To identify and study small RNAs, good and efficient protocols are necessary to isolate them, which sometimes may be challenging due to the composition of specific tissues of certain plant species. Here we describe a simple and efficient method to isolate small RNAs from different plant species. Results We developed a simple and efficient method to isolate small RNAs from different plant species by first comparing different total RNA extraction protocols, followed by streamlining the best one, finally resulting in a small RNA extraction method that has no need of first total RNA extraction and is not based on the commercially available TRIzol® Reagent or columns. This small RNA extraction method not only works well for plant tissues with high polysaccharide content, like cactus, agave, banana, and tomato, but also for plant species like Arabidopsis or tobacco. Furthermore, the obtained small RNA samples were successfully used in northern blot assays. Conclusion Here we provide a simple and efficient method to isolate small RNAs from different plant species, such as cactus, agave, banana, tomato, Arabidopsis, and tobacco, and the small RNAs from this simplified and low cost method is suitable for downstream handling like northern blot assays.

  7. Proposal of a simple screening method for a rapid preliminary evaluation of ''heavy metals'' mobility in soils of contaminated sites

    Energy Technology Data Exchange (ETDEWEB)

    Pinto, Valentina; Chiusolo, Francesca; Cremisini, Carlo [ENEA - Italian Agency for New Technologies, Energy and Environment, Rome (Italy). Section PROTCHIM

    2010-09-15

    Risks associated to ''heavy metals'' (HM) soil contamination depend not only on their total content but, mostly, on their mobility. Many extraction procedures have been developed to evaluate HM mobility in contaminated soils, but they are generally time consuming (especially the sequential extraction procedures (SEPs)) and consequently applicable on a limited number of samples. For this reason, a simple screening method, applicable even ''in field'', has been proposed in order to obtain a rapid evaluation of HM mobility in polluted soils, mainly focused on the fraction associated to Fe and Mn oxide/hydroxides. A buffer solution of trisodium citrate and hydroxylamine hydrochloride was used as extractant for a single-step leaching test. The choice of this buffered solution was strictly related to the possibility of directly determining, via titration with dithizone (DZ), the content of Zn, Cu, Pb and Cd, which are among the most representative contaminants in highly mineralised soils. Moreover, the extraction solution is similar, aside from for the pH value, which is the one used in the BCR SEP second step. The analysis of bivalents ions through DZ titration was exploited in order to further simplify and quicken the whole procedure. The proposed method generically measures, in few minutes, the concentration of total extractable ''heavy metals'' expressed as molL{sup -1} without distinguishing between elements. The proposed screening method has been developed and applied on soil samples collected from rural, urban and mining areas, representing different situation of soil contamination. Results were compared with data obtained from the BCR procedure. The screening method demonstrated to be a reliable tool for a rapid evaluation of metals mobility. Therefore, it could be very useful, even ''in field'', both to guide the sampling activity on site and to monitor the efficacy of the subsequent

  8. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin.

    Science.gov (United States)

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, Søren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equipment. The cryptophyte cells on the filters were disrupted at -80 °C and added phosphate buffer for extraction at 4 °C followed by absorbance measurement. The cryptophyte Rhodomonas salina was used as a model organism. •Simple method for extraction and quantification of phycoerythrin from cryptophytes.•Minimal usage of equipment and chemicals, and low labor costs.•Applicable for industrial and biological purposes.

  9. A simple encapsulation method for organic optoelectronic devices

    International Nuclear Information System (INIS)

    Sun Qian-Qian; An Qiao-Shi; Zhang Fu-Jun

    2014-01-01

    The performances of organic optoelectronic devices, such as organic light emitting diodes and polymer solar cells, have rapidly improved in the past decade. The stability of an organic optoelectronic device has become a key problem for further development. In this paper, we report one simple encapsulation method for organic optoelectronic devices with a parafilm, based on ternary polymer solar cells (PSCs). The power conversion efficiencies (PCE) of PSCs with and without encapsulation decrease from 2.93% to 2.17% and from 2.87% to 1.16% after 168-hours of degradation under an ambient environment, respectively. The stability of PSCs could be enhanced by encapsulation with a parafilm. The encapsulation method is a competitive choice for organic optoelectronic devices, owing to its low cost and compatibility with flexible devices. (atomic and molecular physics)

  10. Determination of Urine Albumin by New Simple High-Performance Liquid Chromatography Method.

    Science.gov (United States)

    Klapkova, Eva; Fortova, Magdalena; Prusa, Richard; Moravcova, Libuse; Kotaska, Karel

    2016-11-01

    A simple high-performance liquid chromatography (HPLC) method was developed for the determination of albumin in patients' urine samples without coeluting proteins and was compared with the immunoturbidimetric determination of albumin. Urine albumin is important biomarker in diabetic patients, but part of it is immuno-nonreactive. Albumin was determined by high-performance liquid chromatography (HPLC), UV detection at 280 nm, Zorbax 300SB-C3 column. Immunoturbidimetric analysis was performed using commercial kit on automatic biochemistry analyzer COBAS INTEGRA ® 400, Roche Diagnostics GmbH, Manheim, Germany. The HLPC method was fully validated. No significant interference with other proteins (transferrin, α-1-acid glycoprotein, α-1-antichymotrypsin, antitrypsin, hemopexin) was found. The results from 301 urine samples were compared with immunochemical determination. We found a statistically significant difference between these methods (P = 0.0001, Mann-Whitney test). New simple HPLC method was developed for the determination of urine albumin without coeluting proteins. Our data indicate that the HPLC method is highly specific and more sensitive than immunoturbidimetry. © 2016 Wiley Periodicals, Inc.

  11. A simple method suitable to study de novo root organogenesis

    Directory of Open Access Journals (Sweden)

    Xiaodong eChen

    2014-05-01

    Full Text Available De novo root organogenesis is the process in which adventitious roots regenerate from detached or wounded plant tissues or organs. In tissue culture, appropriate types and concentrations of plant hormones in the medium are critical for inducing adventitious roots. However, in natural conditions, regeneration from detached organs is likely to rely on endogenous hormones. To investigate the actions of endogenous hormones and the molecular mechanisms guiding de novo root organogenesis, we developed a simple method to imitate natural conditions for adventitious root formation by culturing Arabidopsis thaliana leaf explants on B5 medium without additive hormones. Here we show that the ability of the leaf explants to regenerate roots depends on the age of the leaf and on certain nutrients in the medium. Based on these observations, we provide examples of how this method can be used in different situations, and how it can be optimized. This simple method could be used to investigate the effects of various physiological and molecular changes on the regeneration of adventitious roots. It is also useful for tracing cell lineage during the regeneration process by differential interference contrast observation of -glucuronidase staining, and by live imaging of proteins labeled with fluorescent tags.

  12. Evaluation of normalization methods in mammalian microRNA-Seq data

    Science.gov (United States)

    Garmire, Lana Xia; Subramaniam, Shankar

    2012-01-01

    Simple total tag count normalization is inadequate for microRNA sequencing data generated from the next generation sequencing technology. However, so far systematic evaluation of normalization methods on microRNA sequencing data is lacking. We comprehensively evaluate seven commonly used normalization methods including global normalization, Lowess normalization, Trimmed Mean Method (TMM), quantile normalization, scaling normalization, variance stabilization, and invariant method. We assess these methods on two individual experimental data sets with the empirical statistical metrics of mean square error (MSE) and Kolmogorov-Smirnov (K-S) statistic. Additionally, we evaluate the methods with results from quantitative PCR validation. Our results consistently show that Lowess normalization and quantile normalization perform the best, whereas TMM, a method applied to the RNA-Sequencing normalization, performs the worst. The poor performance of TMM normalization is further evidenced by abnormal results from the test of differential expression (DE) of microRNA-Seq data. Comparing with the models used for DE, the choice of normalization method is the primary factor that affects the results of DE. In summary, Lowess normalization and quantile normalization are recommended for normalizing microRNA-Seq data, whereas the TMM method should be used with caution. PMID:22532701

  13. A simple transformation independent method for outlier definition.

    Science.gov (United States)

    Johansen, Martin Berg; Christensen, Peter Astrup

    2018-04-10

    Definition and elimination of outliers is a key element for medical laboratories establishing or verifying reference intervals (RIs). Especially as inclusion of just a few outlying observations may seriously affect the determination of the reference limits. Many methods have been developed for definition of outliers. Several of these methods are developed for the normal distribution and often data require transformation before outlier elimination. We have developed a non-parametric transformation independent outlier definition. The new method relies on drawing reproducible histograms. This is done by using defined bin sizes above and below the median. The method is compared to the method recommended by CLSI/IFCC, which uses Box-Cox transformation (BCT) and Tukey's fences for outlier definition. The comparison is done on eight simulated distributions and an indirect clinical datasets. The comparison on simulated distributions shows that without outliers added the recommended method in general defines fewer outliers. However, when outliers are added on one side the proposed method often produces better results. With outliers on both sides the methods are equally good. Furthermore, it is found that the presence of outliers affects the BCT, and subsequently affects the determined limits of current recommended methods. This is especially seen in skewed distributions. The proposed outlier definition reproduced current RI limits on clinical data containing outliers. We find our simple transformation independent outlier detection method as good as or better than the currently recommended methods.

  14. Using container weights to determine irrigation needs: A simple method

    Science.gov (United States)

    R. Kasten Dumroese; Mark E. Montville; Jeremiah R. Pinto

    2015-01-01

    Proper irrigation can reduce water use, water waste, and incidence of disease. Knowing when to irrigate plants in container nurseries can be determined by weighing containers. This simple method is quantifiable, which is a benefit when more than one worker is responsible for irrigation. Irrigation is necessary when the container weighs some target as a proportion of...

  15. Numerical Method based on SIMPLE Algorithm for a Two-Phase Flow with Non-condensable Gas

    International Nuclear Information System (INIS)

    Kim, Jong Tae

    2009-08-01

    In this study, a numerical method based on SIMPLE algorithm for a two-phase flow with non-condensable gas has been developed in order to simulate thermal hydraulics in a containment of a nuclear power plant. As governing equations, it adopts a two-fluid three-field model for the two-phase flows. The three fields include gas, drops, and continuous liquid. The gas field can contains vapor and non-condensable gases such as air and hydrogen. In order to resolve mixing phenomena of gas species, gas transport equations for each species base on the gas mass fractions are solved with gas phase governing equations such as mass, momentum and energy equations. Methods to evaluate the properties of the gas species were implemented in the code. They are constant or polynomial function based a user input and a property library from Chemkin and JANAF table for gas specific heat. Properties for the gas mixture which are dependent on mole fractions of the gas species were evaluated by a mix rule

  16. Surface electromyography as a screening method for evaluation of dysphagia and odynophagia

    Science.gov (United States)

    Vaiman, Michael; Eviatar, Ephraim

    2009-01-01

    Objective Patients suspected of having swallowing disorders, could highly benefit from simple diagnostic screening before being referred to specialist evaluations. The article analyzes various instrumental methods of dysphagia assessment, introduces surface electromyography (sEMG) to carry out rapid assessment of such patients, and debates proposed suggestions for sEMG screening protocol in order to identify abnormal deglutition. Data sources Subject related books and articles from 1813 to 2007 were obtained through library search, MEDLINE (1949–2007) and EMBASE (1975–2007). Methods Specifics steps for establishing the protocol for applying the technique for screening purposes (e.g., evaluation of specific muscles), the requirements for diagnostic sEMG equipment, the sEMG technique itself, and defining the tests suitable for assessing deglutition (e.g., saliva, normal, and excessive swallows and uninterrupted drinking of water) are presented in detail. SEMG is compared with other techniques in terms of cost, timing, involvement of radiation, etc. Results According to the published data, SEMG of swallowing is a simple and reliable method for screening and preliminary differentiation among dysphagia and odynophagia of various origins. This noninvasive radiation-free examination has a low level of discomfort, and is simple, time-saving and inexpensive to perform. The major weakness of the method seems to be inability for precise diagnostic of neurologically induced dysphagia. Conclusion With standardization of the technique and an established normative database, sEMG might serve as a reliable screening method for optimal patient management but cannot serve for proper investigation of neurogenic dysphagia. PMID:19232090

  17. Novel surgical performance evaluation approximates Standardized Incidence Ratio with high accuracy at simple means.

    Science.gov (United States)

    Gabbay, Itay E; Gabbay, Uri

    2013-01-01

    Excess adverse events may be attributable to poor surgical performance but also to case-mix, which is controlled through the Standardized Incidence Ratio (SIR). SIR calculations can be complicated, resource consuming, and unfeasible in some settings. This article suggests a novel method for SIR approximation. In order to evaluate a potential SIR surrogate measure we predefined acceptance criteria. We developed a new measure - Approximate Risk Index (ARI). "Number Needed for Event" (NNE) is the theoretical number of patients needed "to produce" one adverse event. ARI is defined as the quotient of the group of patients needed for no observed events Ge by total patients treated Ga. Our evaluation compared 2500 surgical units and over 3 million heterogeneous risk surgical patients that were induced through a computerized simulation. Surgical unit's data were computed for SIR and ARI to evaluate compliance with the predefined criteria. Approximation was evaluated by correlation analysis and performance prediction capability by Receiver Operating Characteristics (ROC) analysis. ARI strongly correlates with SIR (r(2) = 0.87, p 0.9) 87% sensitivity and 91% specificity. ARI provides good approximation of SIR and excellent prediction capability. ARI is simple and cost-effective as it requires thorough risk evaluation of only the adverse events patients. ARI can provide a crucial screening and performance evaluation quality control tool. The ARI method may suit other clinical and epidemiological settings where relatively small fraction of the entire population is affected. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  18. Radiation transport benchmarks for simple geometries with void regions using the spherical harmonics method

    International Nuclear Information System (INIS)

    Kobayashi, K.

    2009-01-01

    In 2001, an international cooperation on the 3D radiation transport benchmarks for simple geometries with void region was performed under the leadership of E. Sartori of OECD/NEA. There were contributions from eight institutions, where 6 contributions were by the discrete ordinate method and only two were by the spherical harmonics method. The 3D spherical harmonics program FFT3 by the finite Fourier transformation method has been improved for this presentation, and benchmark solutions for the 2D and 3D simple geometries with void region by the FFT2 and FFT3 are given showing fairly good accuracy. (authors)

  19. A Simple and Reliable Method of Design for Standalone Photovoltaic Systems

    Science.gov (United States)

    Srinivasarao, Mantri; Sudha, K. Rama; Bhanu, C. V. K.

    2017-06-01

    Standalone photovoltaic (SAPV) systems are seen as a promoting method of electrifying areas of developing world that lack power grid infrastructure. Proliferations of these systems require a design procedure that is simple, reliable and exhibit good performance over its life time. The proposed methodology uses simple empirical formulae and easily available parameters to design SAPV systems, that is, array size with energy storage. After arriving at the different array size (area), performance curves are obtained for optimal design of SAPV system with high amount of reliability in terms of autonomy at a specified value of loss of load probability (LOLP). Based on the array to load ratio (ALR) and levelized energy cost (LEC) through life cycle cost (LCC) analysis, it is shown that the proposed methodology gives better performance, requires simple data and is more reliable when compared with conventional design using monthly average daily load and insolation.

  20. Simple measurement of 14C in the environment using gel suspension method

    International Nuclear Information System (INIS)

    Wakabayashi, Genichiro; Oura, Hirotaka; Nagao, Kenjiro; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa

    1999-01-01

    A gel suspension method using N-lauroyl-L-glutamic-α, γ-dibutylamide as gelling agent and calcium carbonate as sample was studied and it was proved a more simple measurement method of 14 C in environment than the ordinary method. 100, 20 and 7 ml of sample could introduce 3.6, 0.72 and 0.252 g of carbon, respectively. When 100 ml and 20 ml of vial introduced the maximum carbon, the lower limit of detection was about 0.3 dpm/g-C and 0.5 dpm/g-C, respectively. These values showed that this method was able to determine 14 C in the environment. The value of sample has been constant for two years or more. This fact indicated the sample prepared by this method was good for repeat measurement and long-term storage. Many samples prepared by the same calcium carbonate showed almost same values. The concentrations of 14 C in the growth rings of a tree and in rice in the environment were determined and the results agreed with the values in the references. From these above results, this method is more simple measurement method of 14 C in the environment than the ordinary method and can apply to determine 14 C in and around the nuclear installation. (S.Y.)

  1. A simple enzymic method for the synthesis of [32P]phosphoenolpyruvate

    International Nuclear Information System (INIS)

    Parra, F.

    1982-01-01

    A rapid and simple enzymic method is described for the synthesis of [ 32 P]phosphoenolpyruvate from [ 32 P]Psub(i), with a reproducible yield of 74%. The final product was shown to be a good substrate for pyruvate kinase (EC 2.7.1.40). (author)

  2. Simplified methods of evaluating colonies for levels of Varroa Sensitive Hygiene (VSH)

    Science.gov (United States)

    Varroa sensitive hygiene (VSH) is a trait of honey bees, Apis mellifera, that supports resistance to varroa mites, Varroa destructor. Components of VSH were evaluated to identify simple methods for selection of the trait. Varroa mite population growth was measured in colonies with variable levels of...

  3. Diffusion Capillary Phantom vs. Human Data: Outcomes for Reconstruction Methods Depend on Evaluation Medium

    Directory of Open Access Journals (Sweden)

    Sarah D. Lichenstein

    2016-09-01

    Full Text Available Purpose: Diffusion MRI provides a non-invasive way of estimating structural connectivity in the brain. Many studies have used diffusion phantoms as benchmarks to assess the performance of different tractography reconstruction algorithms and assumed that the results can be applied to in vivo studies. Here we examined whether quality metrics derived from a common, publically available, diffusion phantom can reliably predict tractography performance in human white matter tissue. Material and Methods: We compared estimates of fiber length and fiber crossing among a simple tensor model (diffusion tensor imaging, a more complicated model (ball-and-sticks and model-free (diffusion spectrum imaging, generalized q-sampling imaging reconstruction methods using a capillary phantom and in vivo human data (N=14. Results: Our analysis showed that evaluation outcomes differ depending on whether they were obtained from phantom or human data. Specifically, the diffusion phantom favored a more complicated model over a simple tensor model or model-free methods for resolving crossing fibers. On the other hand, the human studies showed the opposite pattern of results, with the model-free methods being more advantageous than model-based methods or simple tensor models. This performance difference was consistent across several metrics, including estimating fiber length and resolving fiber crossings in established white matter pathways. Conclusions: These findings indicate that the construction of current capillary diffusion phantoms tends to favor complicated reconstruction models over a simple tensor model or model-free methods, whereas the in vivo data tends to produce opposite results. This brings into question the previous phantom-based evaluation approaches and suggests that a more realistic phantom or simulation is necessary to accurately predict the relative performance of different tractography reconstruction methods. Acronyms: BSM: ball-and-sticks model; d

  4. A simple evaluation of containment integrity against ex-vessel steam explosion

    International Nuclear Information System (INIS)

    Nishiura, Hiroshi

    2000-01-01

    The guideline for consideration to severe accidents on containment design for next-generation LWR was published in 1999. In order to verify the validity of future containment designs, we have developed a method of assessing for the containment integrity against ex-vessel steam explosion. First, we conducted a simple evaluation on an Advanced PWR. The strength of the reactor cavity wall was assumed to be equivalent to the total strain energy which would accumulate by the time one reinforcing bar element would first reach the failure strain in FEM analyses. As a result, the strength was evaluated to be about 72 MJ. The explosion energy was assumed to be a function of the mass of the dropping melted core and the conversion ratio. Assuming the conversion ratio of 1%, it was estimated that the explosion energy would amount to about 1 MJ if the melt mass corresponds to the break of one instrumentation guide tube penetration, and about 40 MJ if the mass corresponds to the simultaneous break of all penetrations. Therefore, it is expected that the explosion energy would be less than the wall strength; thus, the containment integrity would be maintained even if an ex-vessel steam explosion were to occur. (author)

  5. Accuracy of two simple methods for estimation of thyroidal 131I kinetics for dosimetry-based treatment of Graves' disease

    International Nuclear Information System (INIS)

    Traino, A. C.; Xhafa, B.

    2009-01-01

    One of the major challenges to the more widespread use of individualized, dosimetry-based radioiodine treatment of Graves' disease is the development of a reasonably fast, simple, and cost-effective method to measure thyroidal 131 I kinetics in patients. Even though the fixed activity administration method does not optimize the therapy, giving often too high or too low a dose to the gland, it provides effective treatment for almost 80% of patients without consuming excessive time and resources. In this article two simple methods for the evaluation of the kinetics of 131 I in the thyroid gland are presented and discussed. The first is based on two measurements 4 and 24 h after a diagnostic 131 I administration and the second on one measurement 4 h after such an administration and a linear correlation between this measurement and the maximum uptake in the thyroid. The thyroid absorbed dose calculated by each of the two methods is compared to that calculated by a more complete 131 I kinetics evaluation, based on seven thyroid uptake measurements for 35 patients at various times after the therapy administration. There are differences in the thyroid absorbed doses between those derived by each of the two simpler methods and the ''reference'' value (derived by more complete uptake measurements following the therapeutic 131 I administration), with 20% median and 40% 90-percentile differences for the first method (i.e., based on two thyroid uptake measurements at 4 and 24 h after 131 I administration) and 25% median and 45% 90-percentile differences for the second method (i.e., based on one measurement at 4 h post-administration). Predictably, although relatively fast and convenient, neither of these simpler methods appears to be as accurate as thyroid dose estimates based on more complete kinetic data.

  6. A simple method for generation of back-ground-free gamma-ray spectra

    International Nuclear Information System (INIS)

    Kawarasaki, Y.

    1976-01-01

    A simple and versatile method of generating background-free γ-ray spectra is presented. This method is equivalent to the generation of a continuous background baseline over the entire energy range of spectra corresponding to the original ones obtained with a Ge(Li) detector. These background curves can not be generally expressed in a single and simple analytic form nor in the form of a power series. These background-free spectra thus obtained make it feasible to assign many tiny peaks at the stage of visual inspection of the spectra, which is difficult to do with the original ones. The automatic peak-finding and peak area calculation procedures are both applicable to these background-free spectra. Examples of the application are illustrated. The effect of the peak-shape distortion is also discussed. (Auth.)

  7. Simple Stacking Methods for Silicon Micro Fuel Cells

    Directory of Open Access Journals (Sweden)

    Gianmario Scotti

    2014-08-01

    Full Text Available We present two simple methods, with parallel and serial gas flows, for the stacking of microfabricated silicon fuel cells with integrated current collectors, flow fields and gas diffusion layers. The gas diffusion layer is implemented using black silicon. In the two stacking methods proposed in this work, the fluidic apertures and gas flow topology are rotationally symmetric and enable us to stack fuel cells without an increase in the number of electrical or fluidic ports or interconnects. Thanks to this simplicity and the structural compactness of each cell, the obtained stacks are very thin (~1.6 mm for a two-cell stack. We have fabricated two-cell stacks with two different gas flow topologies and obtained an open-circuit voltage (OCV of 1.6 V and a power density of 63 mW·cm−2, proving the viability of the design.

  8. Simple method of obtaining the band strengths in the electronic spectra of diatomic molecules

    International Nuclear Information System (INIS)

    Gowda, L.S.; Balaji, V.N.

    1977-01-01

    It is shown that relative band strengths of diatomic molecules for which the product of Franck-Condon factor and r-centroid is approximately equal to 1 for (0,0) band can be determined by a simple method which is in good agreement with the smoothed array of experimental values. Such values for the Swan bands of the C 2 molecule are compared with the band strengths of the simple method. It is noted that the Swan bands are one of the outstanding features of R- and N-type stars and of the heads of comets

  9. A Simple Combinatorial Codon Mutagenesis Method for Targeted Protein Engineering.

    Science.gov (United States)

    Belsare, Ketaki D; Andorfer, Mary C; Cardenas, Frida S; Chael, Julia R; Park, Hyun June; Lewis, Jared C

    2017-03-17

    Directed evolution is a powerful tool for optimizing enzymes, and mutagenesis methods that improve enzyme library quality can significantly expedite the evolution process. Here, we report a simple method for targeted combinatorial codon mutagenesis (CCM). To demonstrate the utility of this method for protein engineering, CCM libraries were constructed for cytochrome P450 BM3 , pfu prolyl oligopeptidase, and the flavin-dependent halogenase RebH; 10-26 sites were targeted for codon mutagenesis in each of these enzymes, and libraries with a tunable average of 1-7 codon mutations per gene were generated. Each of these libraries provided improved enzymes for their respective transformations, which highlights the generality, simplicity, and tunability of CCM for targeted protein engineering.

  10. A simple method of digitizing analog scintigrams for quantification and digital archiving. Eine einfache Methode der Digitalisierung von Analogszintigrammen zur Quantifizierung und digitalen Archivierung

    Energy Technology Data Exchange (ETDEWEB)

    Schramm, M. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Kaempfer, B. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Wolf, H. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Clausen, M. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Wendhausen, H. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany)); Henze, E. (Klinik fuer Nuklearmedizin, Kiel Univ. (Germany))

    1993-02-01

    This study was undertaken to evaluate a quick, reliable and cheap method of digitizing analog scintigrams. 40 whole-body bone scintigrams were obtained simultaneously in analog and genuine digital format. The analog scans on X-ray film were then digitized seecondarily by three different methods: 300 dpi flatbed scanning, high-resolution camera scanning and camcorder recording. A simple exposure approach using a light box, a cheap camcorder, a PC and image grabber hard- and software proved to be optimal. Visual interpretation showed no differences in clinical findings when comparing the analog images with their secondarily digitized counterparts. To test the possibility of quantification, 126 equivalent ROIs were drawn both in the genuine digital and the secondarily digitized images. Comparing the ROI count to whole-body count percentage of the corresponding ROIs showed the correlation to be linear. The evaluation of phantom studies showed the linear correlation to be true within a wide activity range. Thus, secondary digitalization of analog scintigrams is an easy, cheap and reliable method of archiving images and allows secondary digital quantification. (orig.)

  11. Multiscale methods coupling atomistic and continuum mechanics: analysis of a simple case

    OpenAIRE

    Blanc , Xavier; Le Bris , Claude; Legoll , Frédéric

    2007-01-01

    International audience; The description and computation of fine scale localized phenomena arising in a material (during nanoindentation, for instance) is a challenging problem that has given birth to many multiscale methods. In this work, we propose an analysis of a simple one-dimensional method that couples two scales, the atomistic one and the continuum mechanics one. The method includes an adaptive criterion in order to split the computational domain into two subdomains, that are described...

  12. A simple method for affinity purification of radiolabeled monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Juweid, M; Sato, J; Paik, C; Onay-Basaran, S; Weinstein, J N; Neumann, R D [National Cancer Inst., Bethesda, MD (United States)

    1993-04-01

    A simple method is described for affinity purification of radiolabeled antibodies using glutaraldehyde-fixed tumor target cells. The cell-bound antibody fraction is removed from the cells by an acid wash and then immediately subjected to buffer-exchange chromatography. The method was applied to the D3 murine monoclonal antibody which binds to a 290 kDa antigen on the surface of Line 10 guinea pig carcinoma cells. No alteration in the molecular size profile was detected after acid washing. Purification resulted in a significant increase in immunoreactivity by an average of 14 [+-] 47% (SD; range 4-30%). (author).

  13. A SIMPLE AND RAPID MATRIX-ASSISTED LASER DESORPTION/IONIZATION TIME OF FLIGHT MASS SPECTROMETRY METHOD TO SCREEN FISH PLASMA SAMPLES FOR ESTROGEN-RESPONSIVE BIOMARKERS

    Science.gov (United States)

    In this study, we describe and evaluate the performance of a simple and rapid mass spectral method for screening fish plasma for estrogen-responsive biomarkers using matrix assisted laster desorption/ionization time of flight mass spectrometry (MALDI-TOF-MS) couopled with a short...

  14. Simple tool for the rapid, automated quantification of glacier advance/retreat observations using multiple methods

    Science.gov (United States)

    Lea, J.

    2017-12-01

    The quantification of glacier change is a key variable within glacier monitoring, with the method used potentially being crucial to ensuring that data can be appropriately compared with environmental data. The topic and timescales of study (e.g. land/marine terminating environments; sub-annual/decadal/centennial/millennial timescales) often mean that different methods are more suitable for different problems. However, depending on the GIS/coding expertise of the user, some methods can potentially be time consuming to undertake, making large-scale studies problematic. In addition, examples exist where different users have nominally applied the same methods in different studies, though with minor methodological inconsistencies in their approach. In turn, this will have implications for data homogeneity where regional/global datasets may be constructed. Here, I present a simple toolbox scripted in a Matlab® environment that requires only glacier margin and glacier centreline data to quantify glacier length, glacier change between observations, rate of change, in addition to other metrics. The toolbox includes the option to apply the established centreline or curvilinear box methods, or a new method: the variable box method - designed for tidewater margins where box width is defined as the total width of the individual terminus observation. The toolbox is extremely flexible, and has the option to be applied as either Matlab® functions within user scripts, or via a graphical user interface (GUI) for those unfamiliar with a coding environment. In both instances, there is potential to apply the methods quickly to large datasets (100s-1000s of glaciers, with potentially similar numbers of observations each), thus ensuring large scale methodological consistency (and therefore data homogeneity) and allowing regional/global scale analyses to be achievable for those with limited GIS/coding experience. The toolbox has been evaluated against idealised scenarios demonstrating

  15. A simple phenotypic method for screening of MCR-1-mediated colistin resistance.

    Science.gov (United States)

    Coppi, M; Cannatelli, A; Antonelli, A; Baccani, I; Di Pilato, V; Sennati, S; Giani, T; Rossolini, G M

    2018-02-01

    To evaluate a novel method, the colistin-MAC test, for phenotypic screening of acquired colistin resistance mediated by transferable mcr-1 resistance determinants, based on colistin MIC reduction in the presence of dipicolinic acid (DPA). The colistin-MAC test consists in a broth microdilution method, in which colistin MIC is tested in the absence or presence of DPA (900 μg/mL). Overall, 74 colistin-resistant strains of Enterobacteriaceae (65 Escherichia coli and nine other species), including 61 strains carrying mcr-1-like genes and 13 strains negative for mcr genes, were evaluated with the colistin-MAC test. The presence of mcr-1-like and mcr-2-like genes was assessed by real-time PCR and end-point PCR. For 20 strains, whole-genome sequencing data were also available. A ≥8-fold reduction of colistin MIC in the presence of DPA was observed with 59 mcr-1-positive strains, including 53 E. coli of clinical origin, three E. coli transconjugants carrying MCR-1-encoding plasmids, one Enterobacter cloacae complex and two Citrobacter spp. Colistin MICs were unchanged, increased or at most reduced by twofold with the 13 mcr-negative colistin-resistant strains (nine E. coli and four Klebsiella pneumoniae), but also with two mcr-1-like-positive K. pneumoniae strains. The colistin-MAC test could be a simple phenotypic test for presumptive identification of mcr-1-positive strains among isolates of colistin-resistant E. coli, based on a ≥8-fold reduction of colistin MIC in the presence of DPA. Evaluation of the test with a larger number of strains, species and mcr-type resistance determinants would be of interest. Copyright © 2017 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  16. A fast, simple method for screening radiation susceptibility genes by RNA interference

    International Nuclear Information System (INIS)

    Tsuji, Atsushi B.; Sudo, Hitomi; Sugyo, Aya; Otsuki, Marika; Miyagishi, Makoto; Taira, Kazunari; Imai, Takashi; Harada, Yoshi-nobu

    2005-01-01

    Radiotherapy can cause unacceptable levels of damage to normal tissues in some cancer patients. To understand the molecular mechanisms underlying radiation-induced physiological responses, and to be able to predict the radiation susceptibility of normal tissues in individual patients, it is important to identify a comprehensive set of genes responsible for radiation susceptibility. We have developed a simple and rapid 96-well screening protocol using cell proliferation assays and RNA interference to identify genes associated with radiation susceptibility. We evaluated the performance of alamarBlue-, BrdU-, and sulforhodamine B-based cell proliferation assays using the 96-well format. Each proliferation assay detected the known radiation susceptibility gene, PRKDC. In a trial screen using 28 shRNA vectors, another known gene, CDKN1A, and one new radiation susceptibility gene, ATP5G3, were identified. Our results indicate that this method may be useful for large-scale screens designed to identify novel radiation susceptibility genes

  17. Radiochemical method for evaluating the effect of antibiotics on Escherichia coli biofilms

    International Nuclear Information System (INIS)

    Dix, B.A.; Cohen, P.S.; Laux, D.C.; Cleeland, R.

    1988-01-01

    A simple radiochemical method for evaluating the action of antibiotics on Escherichia coli cells in biofilms is reported. After growth, biofilms of E. coli ATCC 25922 on disks of urinary catheter material were suspended in fresh medium containing or lacking an antibiotic, incubated for 4 h at 37 degrees C, and pulse-labeled with [ 3 H]leucine for 5 min. Radioactivity in trichloracetic acid-precipitable material in the biofilm and in the surrounding medium (planktonic E. coli) was then measured. Antibiotic-induced inhibition of incorporation of [ 3 H]leucine into the cells in the biofilm was far less pronounced than incorporation into planktonic cells and, furthermore, correlated well with loss in viable counts. The method is simple, inexpensive, and extremely timesaving

  18. A simple method of screening for metabolic bone disease

    International Nuclear Information System (INIS)

    Broughton, R.B.K.; Evans, W.D.

    1982-01-01

    The purpose of this investigation was to find a simple method -to be used as an adjunct to the conventional bone scintigram- that could differentiate between decreased bone metabolism or mass, i.e., osteoporosis -normal bone- and the group of conditions of increased bone metabolism or mass namely, osteomalacia, renal osteodystrophy, hyperparathyroidism and Paget's disease. The Fogelman's method using the bone to soft tissue ratios from region of interest analysis at 4 hours post injection, was adopted. An initial experience in measuring a value for the count rate density in lumbar vertebrae at 1 hr post injection during conventional bone scintigraphy appears to give a clear indication of the overall rate of bone metabolism. The advantage over whole body retention methods is that the scan performed at the end of the metabolic study will reveal localized bone disease that may otherwise not be anticipated

  19. Exploring simple assessment methods for lighting quality with architecture and design students

    DEFF Research Database (Denmark)

    Madsen, Merete

    2006-01-01

    that cannot be assessed by simple equations or rules-of-thumb. Balancing the many an often contradictory aspects of energy efficiency and high quality lighting design is a complex undertaking not just for students. The work described in this paper is one result of an academic staff exchange between...... the Schools of Architecture in Copenhagen and Victoria University of Wellington (New Zealand). The authors explore two approaches to teaching students simple assessment methods that can contribute to making more informed decisions about the luminous environment and its quality. One approach deals...... with the assessment of luminance ratios in relation to computer work and presents in that context some results from an experiment undertaken to introduce the concept of luminance ratios and preferred luminance ranges to architeture students. In the other approach a Danish method for assissing the luminance...

  20. 12 CFR 717.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... simple methods for exercising an opt-out right do not include— (i) Requiring the consumer to write his or... out. (a) In general. You must not use eligibility information about a consumer that you receive from an affiliate to make a solicitation to the consumer about your products or services, unless the...

  1. A simple in situ visual and tristimulus colorimetric method for the determination of diphosgene in air

    Directory of Open Access Journals (Sweden)

    VLADIMÍR PITSCHMANN

    2007-10-01

    Full Text Available A simple visual and tristimulus colorimetric method (three-dimensional system CIE–L*a*b* for the determination of trace amounts of diphosgene in air has been developed. The method is based on the suction of diphosgene vapors through a modified cotton fabric filter fixed in a special adapter. Prior to analysis, the filter is saturated with a chromogenic reagent based on 4-(p-nitrobenzylpyridine. The optimal composition of the reagent is 2 g of 4-(p-nitrobenzylpyridine and 4 g of N-phenylbenzylamine in 100 ml of a 50:50 ethanol–glycerol mixture. The intensity of the formed red coloration of the filter is evaluated visually or by a tristimulus colorimeter (LMG 173, Lange, Germany. The detection limit is 0.01 mg m-3. Acetyl chloride and benzoyl chloride react in 150 and 50 times higher concentrations, respecttively. The method is suitable for mobile field analysis.

  2. A simple method for the prevention of endometrial autolysis in hysterectomy specimens

    OpenAIRE

    Houghton, J P; Roddy, S; Carroll, S; McCluggage, W G

    2004-01-01

    Aims: Uteri are among the most common surgical pathology specimens. Assessment of the endometrium is often difficult because of pronounced tissue autolysis. This study describes a simple method to prevent endometrial autolysis and aid in interpretation of the endometrium.

  3. A simple method for estimating the entropy of neural activity

    International Nuclear Information System (INIS)

    Berry II, Michael J; Tkačik, Gašper; Dubuis, Julien; Marre, Olivier; Da Silveira, Rava Azeredo

    2013-01-01

    The number of possible activity patterns in a population of neurons grows exponentially with the size of the population. Typical experiments explore only a tiny fraction of the large space of possible activity patterns in the case of populations with more than 10 or 20 neurons. It is thus impossible, in this undersampled regime, to estimate the probabilities with which most of the activity patterns occur. As a result, the corresponding entropy—which is a measure of the computational power of the neural population—cannot be estimated directly. We propose a simple scheme for estimating the entropy in the undersampled regime, which bounds its value from both below and above. The lower bound is the usual ‘naive’ entropy of the experimental frequencies. The upper bound results from a hybrid approximation of the entropy which makes use of the naive estimate, a maximum entropy fit, and a coverage adjustment. We apply our simple scheme to artificial data, in order to check their accuracy; we also compare its performance to those of several previously defined entropy estimators. We then apply it to actual measurements of neural activity in populations with up to 100 cells. Finally, we discuss the similarities and differences between the proposed simple estimation scheme and various earlier methods. (paper)

  4. Service Quality Evaluation of Restaurants Using The Ahp And Topsis Method

    OpenAIRE

    YILDIZ, Salih; YILDIZ, Emel

    2015-01-01

    The purpose of this study is to determine the factors affecting service quality at restaurants that operate in the service industry. Three restaurants operating in Trabzon were analyzed in terms of the quality of service they provided. In the study, the simple sampling random method was applied to 300 face-to-face interviews in which 30 surveys were deemed invalid and thus eliminated, resulting in a total of 270 surveys being evaluated. The Analytical Hierarchy Process (AHP) method was used t...

  5. A simple method of fabricating mask-free microfluidic devices for biological analysis.

    KAUST Repository

    Yi, Xin; Kodzius, Rimantas; Gong, Xiuqing; Xiao, Kang; Wen, Weijia

    2010-01-01

    We report a simple, low-cost, rapid, and mask-free method to fabricate two-dimensional (2D) and three-dimensional (3D) microfluidic chip for biological analysis researches. In this fabrication process, a laser system is used to cut through paper

  6. PENDISC: a simple method for constructing a mathematical model from time-series data of metabolite concentrations.

    Science.gov (United States)

    Sriyudthsak, Kansuporn; Iwata, Michio; Hirai, Masami Yokota; Shiraishi, Fumihide

    2014-06-01

    The availability of large-scale datasets has led to more effort being made to understand characteristics of metabolic reaction networks. However, because the large-scale data are semi-quantitative, and may contain biological variations and/or analytical errors, it remains a challenge to construct a mathematical model with precise parameters using only these data. The present work proposes a simple method, referred to as PENDISC (Parameter Estimation in a N on- DImensionalized S-system with Constraints), to assist the complex process of parameter estimation in the construction of a mathematical model for a given metabolic reaction system. The PENDISC method was evaluated using two simple mathematical models: a linear metabolic pathway model with inhibition and a branched metabolic pathway model with inhibition and activation. The results indicate that a smaller number of data points and rate constant parameters enhances the agreement between calculated values and time-series data of metabolite concentrations, and leads to faster convergence when the same initial estimates are used for the fitting. This method is also shown to be applicable to noisy time-series data and to unmeasurable metabolite concentrations in a network, and to have a potential to handle metabolome data of a relatively large-scale metabolic reaction system. Furthermore, it was applied to aspartate-derived amino acid biosynthesis in Arabidopsis thaliana plant. The result provides confirmation that the mathematical model constructed satisfactorily agrees with the time-series datasets of seven metabolite concentrations.

  7. Use of eddy-covariance methods to "calibrate" simple estimators of evapotranspiration

    Science.gov (United States)

    Sumner, David M.; Geurink, Jeffrey S.; Swancar, Amy

    2017-01-01

    Direct measurement of actual evapotranspiration (ET) provides quantification of this large component of the hydrologic budget, but typically requires long periods of record and large instrumentation and labor costs. Simple surrogate methods of estimating ET, if “calibrated” to direct measurements of ET, provide a reliable means to quantify ET. Eddy-covariance measurements of ET were made for 12 years (2004-2015) at an unimproved bahiagrass (Paspalum notatum) pasture in Florida. These measurements were compared to annual rainfall derived from rain gage data and monthly potential ET (PET) obtained from a long-term (since 1995) U.S. Geological Survey (USGS) statewide, 2-kilometer, daily PET product. The annual proportion of ET to rainfall indicates a strong correlation (r2=0.86) to annual rainfall; the ratio increases linearly with decreasing rainfall. Monthly ET rates correlated closely (r2=0.84) to the USGS PET product. The results indicate that simple surrogate methods of estimating actual ET show positive potential in the humid Florida climate given the ready availability of historical rainfall and PET.

  8. A novel method for the accurate evaluation of Poisson's ratio of soft polymer materials.

    Science.gov (United States)

    Lee, Jae-Hoon; Lee, Sang-Soo; Chang, Jun-Dong; Thompson, Mark S; Kang, Dong-Joong; Park, Sungchan; Park, Seonghun

    2013-01-01

    A new method with a simple algorithm was developed to accurately measure Poisson's ratio of soft materials such as polyvinyl alcohol hydrogel (PVA-H) with a custom experimental apparatus consisting of a tension device, a micro X-Y stage, an optical microscope, and a charge-coupled device camera. In the proposed method, the initial positions of the four vertices of an arbitrarily selected quadrilateral from the sample surface were first measured to generate a 2D 1st-order 4-node quadrilateral element for finite element numerical analysis. Next, minimum and maximum principal strains were calculated from differences between the initial and deformed shapes of the quadrilateral under tension. Finally, Poisson's ratio of PVA-H was determined by the ratio of minimum principal strain to maximum principal strain. This novel method has an advantage in the accurate evaluation of Poisson's ratio despite misalignment between specimens and experimental devices. In this study, Poisson's ratio of PVA-H was 0.44 ± 0.025 (n = 6) for 2.6-47.0% elongations with a tendency to decrease with increasing elongation. The current evaluation method of Poisson's ratio with a simple measurement system can be employed to a real-time automated vision-tracking system which is used to accurately evaluate the material properties of various soft materials.

  9. A simple method of chaos control for a class of chaotic discrete-time systems

    International Nuclear Information System (INIS)

    Jiang Guoping; Zheng Weixing

    2005-01-01

    In this paper, a simple method is proposed for chaos control for a class of discrete-time chaotic systems. The proposed method is built upon the state feedback control and the characteristic of ergodicity of chaos. The feedback gain matrix of the controller is designed using a simple criterion, so that control parameters can be selected via the pole placement technique of linear control theory. The new controller has a feature that it only uses the state variable for control and does not require the target equilibrium point in the feedback path. Moreover, the proposed control method cannot only overcome the so-called 'odd eigenvalues number limitation' of delayed feedback control, but also control the chaotic systems to the specified equilibrium points. The effectiveness of the proposed method is demonstrated by a two-dimensional discrete-time chaotic system

  10. 12 CFR 571.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... CREDIT REPORTING Affiliate Marketing § 571.25 Reasonable and simple methods of opting out. (a) In general... out, such as a form that can be electronically mailed or processed at an Internet Web site, if the... (15 U.S.C. 6801 et seq.), the affiliate sharing opt-out under the Act, and the affiliate marketing opt...

  11. 16 CFR 680.25 - Reasonable and simple methods of opting out.

    Science.gov (United States)

    2010-01-01

    ... AFFILIATE MARKETING § 680.25 Reasonable and simple methods of opting out. (a) In general. You must not use... a form that can be electronically mailed or processed at an Internet Web site, if the consumer..., 15 U.S.C. 6801 et seq., the affiliate sharing opt-out under the Act, and the affiliate marketing opt...

  12. A Simple Method to Measure Nematodes' Propulsive Thrust and the Nematode Ratchet.

    Science.gov (United States)

    Bau, Haim; Yuan, Jinzhou; Raizen, David

    2015-11-01

    Since the propulsive thrust of micro organisms provides a more sensitive indicator of the animal's health and response to drugs than motility, a simple, high throughput, direct measurement of the thrust is desired. Taking advantage of the nematode C. elegans being heavier than water, we devised a simple method to determine the propulsive thrust of the animals by monitoring their velocity when swimming along an inclined plane. We find that the swimming velocity is a linear function of the sin of the inclination angle. This method allows us to determine, among other things, the animas' propulsive thrust as a function of genotype, drugs, and age. Furthermore, taking advantage of the animals' inability to swim over a stiff incline, we constructed a sawteeth ratchet-like track that restricts the animals to swim in a predetermined direction. This research was supported, in part, by NIH NIA Grant 5R03AG042690-02.

  13. Outcomes in Patients Treated with a Novel, Simple Method for Hemostasis of Dermal Avulsion Injuries.

    Science.gov (United States)

    Dowling, Sean Taylor; Lin, Brian Wai

    2017-10-01

    A recently described technique proposes a simple method to achieve permanent hemostasis of distal fingertip dermal avulsion injuries. It is simple to learn and easy to perform with readily available materials found in most emergency departments. However, long-term outcomes for patients treated with this technique have not yet been evaluated. A primary objective of the current article is to provide safety data for the technique using an off-label product indication. Emergency department of Kaiser Permanente Medical Center, San Francisco, California. Six patients were treated in the emergency department for fingertip dermal avulsion injuries using a tourniquet and tissue adhesive glue (Dermabond by Ethicon, Somerville, New Jersey). Patients were subsequently contacted to assess healing and satisfaction with cosmetic outcome through interview and photographs of their wounds at 9 months following the date of injury. All 6 patients were satisfied with the cosmetic outcome of treatment, and none received a diagnosis of serious complications. This series demonstrates cosmetic outcomes for injuries treated with the technique, highlights potential problems that may be perceived by patients during their clinical course, and creates the groundwork for a larger clinical study examining the use of the technique.

  14. A simple and fast method for extraction and quantification of cryptophyte phycoerythrin

    OpenAIRE

    Thoisen, Christina; Hansen, Benni Winding; Nielsen, S?ren Laurentius

    2017-01-01

    The microalgal pigment phycoerythrin (PE) is of commercial interest as natural colorant in food and cosmetics, as well as fluoroprobes for laboratory analysis. Several methods for extraction and quantification of PE are available but they comprise typically various extraction buffers, repetitive freeze-thaw cycles and liquid nitrogen, making extraction procedures more complicated. A simple method for extraction of PE from cryptophytes is described using standard laboratory materials and equip...

  15. A Simple Plasma Retinol Isotope Ratio Method for Estimating β-Carotene Relative Bioefficacy in Humans: Validation with the Use of Model-Based Compartmental Analysis.

    Science.gov (United States)

    Ford, Jennifer Lynn; Green, Joanne Balmer; Lietz, Georg; Oxley, Anthony; Green, Michael H

    2017-09-01

    Background: Provitamin A carotenoids are an important source of dietary vitamin A for many populations. Thus, accurate and simple methods for estimating carotenoid bioefficacy are needed to evaluate the vitamin A value of test solutions and plant sources. β-Carotene bioefficacy is often estimated from the ratio of the areas under plasma isotope response curves after subjects ingest labeled β-carotene and a labeled retinyl acetate reference dose [isotope reference method (IRM)], but to our knowledge, the method has not yet been evaluated for accuracy. Objectives: Our objectives were to develop and test a physiologically based compartmental model that includes both absorptive and postabsorptive β-carotene bioconversion and to use the model to evaluate the accuracy of the IRM and a simple plasma retinol isotope ratio [(RIR), labeled β-carotene-derived retinol/labeled reference-dose-derived retinol in one plasma sample] for estimating relative bioefficacy. Methods: We used model-based compartmental analysis (Simulation, Analysis and Modeling software) to develop and apply a model that provided known values for β-carotene bioefficacy. Theoretical data for 10 subjects were generated by the model and used to determine bioefficacy by RIR and IRM; predictions were compared with known values. We also applied RIR and IRM to previously published data. Results: Plasma RIR accurately predicted β-carotene relative bioefficacy at 14 d or later. IRM also accurately predicted bioefficacy by 14 d, except that, when there was substantial postabsorptive bioconversion, IRM underestimated bioefficacy. Based on our model, 1-d predictions of relative bioefficacy include absorptive plus a portion of early postabsorptive conversion. Conclusion: The plasma RIR is a simple tracer method that accurately predicts β-carotene relative bioefficacy based on analysis of one blood sample obtained at ≥14 d after co-ingestion of labeled β-carotene and retinyl acetate. The method also provides

  16. A simple method of equine limb force vector analysis and its potential applications

    Directory of Open Access Journals (Sweden)

    Sarah Jane Hobbs

    2018-02-01

    Full Text Available Background Ground reaction forces (GRF measured during equine gait analysis are typically evaluated by analyzing discrete values obtained from continuous force-time data for the vertical, longitudinal and transverse GRF components. This paper describes a simple, temporo-spatial method of displaying and analyzing sagittal plane GRF vectors. In addition, the application of statistical parametric mapping (SPM is introduced to analyse differences between contra-lateral fore and hindlimb force-time curves throughout the stance phase. The overall aim of the study was to demonstrate alternative methods of evaluating functional (asymmetry within horses. Methods GRF and kinematic data were collected from 10 horses trotting over a series of four force plates (120 Hz. The kinematic data were used to determine clean hoof contacts. The stance phase of each hoof was determined using a 50 N threshold. Vertical and longitudinal GRF for each stance phase were plotted both as force-time curves and as force vector diagrams in which vectors originating at the centre of pressure on the force plate were drawn at intervals of 8.3 ms for the duration of stance. Visual evaluation was facilitated by overlay of the vector diagrams for different limbs. Summary vectors representing the magnitude (VecMag and direction (VecAng of the mean force over the entire stance phase were superimposed on the force vector diagram. Typical measurements extracted from the force-time curves (peak forces, impulses were compared with VecMag and VecAng using partial correlation (controlling for speed. Paired samples t-tests (left v. right diagonal pair comparison and high v. low vertical force diagonal pair comparison were performed on discrete and vector variables using traditional methods and Hotelling’s T2 tests on normalized stance phase data using SPM. Results Evidence from traditional statistical tests suggested that VecMag is more influenced by the vertical force and impulse, whereas

  17. A new semiquantitative method for evaluation of metastasis progression.

    Science.gov (United States)

    Volarevic, A; Ljujic, B; Volarevic, V; Milovanovic, M; Kanjevac, T; Lukic, A; Arsenijevic, N

    2012-01-01

    Although recent technical advancements are directed toward developing novel assays and methods for detection of micro and macro metastasis, there are still no reports of reliable, simple to use imaging software that could be used for the detection and quantification of metastasis in tissue sections. We herein report a new semiquantitative method for evaluation of metastasis progression in a well established 4T1 orthotopic mouse model of breast cancer metastasis. The new semiquantitative method presented here was implemented by using the Autodesk AutoCAD 2012 program, a computer-aided design program used primarily for preparing technical drawings in 2 dimensions. By using the Autodesk AutoCAD 2012 software- aided graphical evaluation we managed to detect each metastatic lesion and we precisely calculated the average percentage of lung and liver tissue parenchyma with metastasis in 4T1 tumor-bearing mice. The data were highly specific and relevant to descriptive histological analysis, confirming reliability and accuracy of the AutoCAD 2012 software as new method for quantification of metastatic lesions. The new semiquantitative method using AutoCAD 2012 software provides a novel approach for the estimation of metastatic progression in histological tissue sections.

  18. Simple method for absolute calibration of geophones, seismometers, and other inertial vibration sensors

    International Nuclear Information System (INIS)

    Kann, Frank van; Winterflood, John

    2005-01-01

    A simple but powerful method is presented for calibrating geophones, seismometers, and other inertial vibration sensors, including passive accelerometers. The method requires no cumbersome or expensive fixtures such as shaker platforms and can be performed using a standard instrument commonly available in the field. An absolute calibration is obtained using the reciprocity property of the device, based on the standard mathematical model for such inertial sensors. It requires only simple electrical measurement of the impedance of the sensor as a function of frequency to determine the parameters of the model and hence the sensitivity function. The method is particularly convenient if one of these parameters, namely the suspended mass is known. In this case, no additional mechanical apparatus is required and only a single set of impedance measurements yields the desired calibration function. Moreover, this measurement can be made with the device in situ. However, the novel and most powerful aspect of the method is its ability to accurately determine the effective suspended mass. For this, the impedance measurement is made with the device hanging from a simple spring or flexible cord (depending on the orientation of its sensitive axis). To complete the calibration, the device is weighed to determine its total mass. All the required calibration parameters, including the suspended mass, are then determined from a least-squares fit to the impedance as a function of frequency. A demonstration using both a 4.5 Hz geophone and a 1 Hz seismometer shows that the method can yield accurate absolute calibrations with an error of 0.1% or better, assuming no a priori knowledge of any parameters

  19. A new method to evaluate neutron spectra for bnct

    International Nuclear Information System (INIS)

    Martin Hernandez, Guido

    2001-01-01

    This paper deals with the development of a method to evaluate neutron spectra for BNCT. Physical dose deposition calculations for different neutron energies, ranging from thermal to fast, were performed. A matrix, containing dose for each energy and position in the beam center line was obtained. MCNP 4B and Snyder's head model were used. A simple computer code containing the matrix calculates the dose for each point in the beam center line depending on the input energy spectrum to be evaluated. The output of this program is the dose distribution in the brain and the dose gain, that is the ratio between dose to tumor and maximum dose to healthy tissue maximum

  20. Simple, reliable, and nondestructive method for the measurement of vacuum pressure without specialized equipment.

    Science.gov (United States)

    Yuan, Jin-Peng; Ji, Zhong-Hua; Zhao, Yan-Ting; Chang, Xue-Fang; Xiao, Lian-Tuan; Jia, Suo-Tang

    2013-09-01

    We present a simple, reliable, and nondestructive method for the measurement of vacuum pressure in a magneto-optical trap. The vacuum pressure is verified to be proportional to the collision rate constant between cold atoms and the background gas with a coefficient k, which can be calculated by means of the simple ideal gas law. The rate constant for loss due to collisions with all background gases can be derived from the total collision loss rate by a series of loading curves of cold atoms under different trapping laser intensities. The presented method is also applicable for other cold atomic systems and meets the miniaturization requirement of commercial applications.

  1. Application of the Bow Tie method for evaluation of safety in the procedure of logging wells

    International Nuclear Information System (INIS)

    Alfonso Pallares, C; Perez Reyes, Y.; Sarabia Molina, I.I.

    2013-01-01

    This work consists of an assessment of security in the practice of logging of oil wells, using the method of Bow Tie for being a simple method of evaluation of the risk, which makes it possible in a structured way to set priorities to manage risk

  2. A simple bacterial turbidimetric method for detection of some radurized foods

    International Nuclear Information System (INIS)

    Gautam, S.; Sharma, Arun; Thomas, Paul

    1998-01-01

    A simple and quick method for detection of irradiated food is proposed. The method is based on the principle of microbial contribution to the development of turbidity in a clear medium. It employs measurement of absorbance at 600 nm of the medium after the test commodity has been suspended and shaken in it for a fixed interval. The differences in the bacterial turbidity from irradiated and nonirradiated samples are quite marked so as to allow identification of the irradiated foods like fish, lamb meat, chicken and mushroom. (author)

  3. Accurate and simple measurement method of complex decay schemes radionuclide activity

    International Nuclear Information System (INIS)

    Legrand, J.; Clement, C.; Bac, C.

    1975-01-01

    A simple method for the measurement of the activity is described. It consists of using a well-type sodium iodide crystal whose efficiency mith monoenergetic photon rays has been computed or measured. For each radionuclide with a complex decay scheme a total efficiency is computed; it is shown that the efficiency is very high, near 100%. The associated incertainty is low, in spite of the important uncertainties on the different parameters used in the computation. The method has been applied to the measurement of the 152 Eu primary reference [fr

  4. A SIMPLE AND EFFECTIVE CURSIVE WORD SEGMENTATION METHOD

    NARCIS (Netherlands)

    nicchiotti, G.; Rimassa, S.; Scagliola, C.

    2004-01-01

    A simple procedure for cursive word oversegmentation is presented, which is based on the analysis of the handwritten profiles and on the extraction of ``white holes\\'\\'. It follows the policy of using simple rules on complex data and sophisticated rules on simpler data. Experimental results show

  5. Direct integral linear least square regression method for kinetic evaluation of hepatobiliary scintigraphy

    International Nuclear Information System (INIS)

    Shuke, Noriyuki

    1991-01-01

    In hepatobiliary scintigraphy, kinetic model analysis, which provides kinetic parameters like hepatic extraction or excretion rate, have been done for quantitative evaluation of liver function. In this analysis, unknown model parameters are usually determined using nonlinear least square regression method (NLS method) where iterative calculation and initial estimate for unknown parameters are required. As a simple alternative to NLS method, direct integral linear least square regression method (DILS method), which can determine model parameters by a simple calculation without initial estimate, is proposed, and tested the applicability to analysis of hepatobiliary scintigraphy. In order to see whether DILS method could determine model parameters as good as NLS method, or to determine appropriate weight for DILS method, simulated theoretical data based on prefixed parameters were fitted to 1 compartment model using both DILS method with various weightings and NLS method. The parameter values obtained were then compared with prefixed values which were used for data generation. The effect of various weights on the error of parameter estimate was examined, and inverse of time was found to be the best weight to make the error minimum. When using this weight, DILS method could give parameter values close to those obtained by NLS method and both parameter values were very close to prefixed values. With appropriate weighting, the DILS method could provide reliable parameter estimate which is relatively insensitive to the data noise. In conclusion, the DILS method could be used as a simple alternative to NLS method, providing reliable parameter estimate. (author)

  6. Simple Moving Voltage Average Incremental Conductance MPPT Technique with Direct Control Method under Nonuniform Solar Irradiance Conditions

    Directory of Open Access Journals (Sweden)

    Amjad Ali

    2015-01-01

    Full Text Available A new simple moving voltage average (SMVA technique with fixed step direct control incremental conductance method is introduced to reduce solar photovoltaic voltage (VPV oscillation under nonuniform solar irradiation conditions. To evaluate and validate the performance of the proposed SMVA method in comparison with the conventional fixed step direct control incremental conductance method under extreme conditions, different scenarios were simulated. Simulation results show that in most cases SMVA gives better results with more stability as compared to traditional fixed step direct control INC with faster tracking system along with reduction in sustained oscillations and possesses fast steady state response and robustness. The steady state oscillations are almost eliminated because of extremely small dP/dV around maximum power (MP, which verify that the proposed method is suitable for standalone PV system under extreme weather conditions not only in terms of bus voltage stability but also in overall system efficiency.

  7. A simple method for determining split renal function from dynamic {sup 99m}Tc-MAG3 scintigraphic data

    Energy Technology Data Exchange (ETDEWEB)

    Wesolowski, Michal J.; Watson, Gage; Wanasundara, Surajith N.; Babyn, Paul [University of Saskatchewan, Department of Medical Imaging, Saskatoon, SK (Canada); Conrad, Gary R. [University of Kentucky College of Medicine, Department of Radiology, Lexington, KY (United States); Samal, Martin [Charles University Prague and the General University Hospital in Prague, Department of Nuclear Medicine, First Faculty of Medicine, Praha 2 (Czech Republic); Wesolowski, Carl A. [University of Saskatchewan, Department of Medical Imaging, Saskatoon, SK (Canada); Memorial University of Newfoundland, Department of Radiology, St. John' s, NL (Canada)

    2016-03-15

    Commonly used methods for determining split renal function (SRF) from dynamic scintigraphic data require extrarenal background subtraction and additional correction for intrarenal vascular activity. The use of these additional regions of interest (ROIs) can produce inaccurate results and be challenging, e.g. if the heart is out of the camera field of view. The purpose of this study was to evaluate a new method for determining SRF called the blood pool compensation (BPC) technique, which is simple to implement, does not require extrarenal background correction and intrinsically corrects for intrarenal vascular activity. In the BPC method SRF is derived from a parametric plot of the curves generated by one blood-pool and two renal ROIs. Data from 107 patients who underwent {sup 99m}Tc-MAG3 scintigraphy were used to determine SRF values. Values calculated using the BPC method were compared to those obtained with the integral (IN) and Patlak-Rutland (PR) techniques using Bland-Altman plotting and Passing-Bablok regression. The interobserver variability of the BPC technique was also assessed for two observers. The SRF values obtained with the BPC method did not differ significantly from those obtained with the PR method and showed no consistent bias, while SRF values obtained with the IN method showed significant differences with some bias in comparison to those obtained with either the PR or BPC method. No significant interobserver variability was found between two observers calculating SRF using the BPC method. The BPC method requires only three ROIs to produce reliable estimates of SRF, was simple to implement, and in this study yielded statistically equivalent results to the PR method with appreciable interobserver agreement. As such, it adds a new reliable method for quality control of monitoring relative kidney function. (orig.)

  8. Validation of a simple and inexpensive method for the quantitation of infarct in the rat brain

    Directory of Open Access Journals (Sweden)

    C.L.R. Schilichting

    2004-04-01

    Full Text Available A gravimetric method was evaluated as a simple, sensitive, reproducible, low-cost alternative to quantify the extent of brain infarct after occlusion of the medial cerebral artery in rats. In ether-anesthetized rats, the left medial cerebral artery was occluded for 1, 1.5 or 2 h by inserting a 4-0 nylon monofilament suture into the internal carotid artery. Twenty-four hours later, the brains were processed for histochemical triphenyltetrazolium chloride (TTC staining and quantitation of the schemic infarct. In each TTC-stained brain section, the ischemic tissue was dissected with a scalpel and fixed in 10% formalin at 0ºC until its total mass could be estimated. The mass (mg of the ischemic tissue was weighed on an analytical balance and compared to its volume (mm³, estimated either by plethysmometry using platinum electrodes or by computer-assisted image analysis. Infarct size as measured by the weighing method (mg, and reported as a percent (% of the affected (left hemisphere, correlated closely with volume (mm³, also reported as % estimated by computerized image analysis (r = 0.88; P < 0.001; N = 10 or by plethysmography (r = 0.97-0.98; P < 0.0001; N = 41. This degree of correlation was maintained between different experimenters. The method was also sensitive for detecting the effect of different ischemia durations on infarct size (P < 0.005; N = 23, and the effect of drug treatments in reducing the extent of brain damage (P < 0.005; N = 24. The data suggest that, in addition to being simple and low cost, the weighing method is a reliable alternative for quantifying brain infarct in animal models of stroke.

  9. A Study of Simple α Source Preparation Using a Micro-coprecipitation Method

    International Nuclear Information System (INIS)

    Lee, Myung Ho; Park, Taehong; Song, Byung Chul; Park, Jong Ho; Song, Kyuseok

    2012-01-01

    This study presents a rapid and simple α source preparation method for a radioactive waste sample. The recovery of 239 Pu, 232 U and 243 Am using a micro-coprecipitation method was over 95%. The α-peak resolution of Pu and Am isotopes through the micro-coprecipitation method is enough to discriminate the Pu and Am isotopes from other Pu and Am isotopes. The determination of the Pu and Am isotopes using the micro-coprecipitation method was applied to the radioactive waste sample, so that the activity concentrations of the Pu and Am isotopes using the micro-coprecipitation method in the radioactive waste sample were similar to those using the electrodeposition method

  10. Evaluation of a Class of Simple and Effective Uncertainty Methods for Sparse Samples of Random Variables and Functions

    Energy Technology Data Exchange (ETDEWEB)

    Romero, Vicente [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Bonney, Matthew [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Schroeder, Benjamin [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Weirs, V. Gregory [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-11-01

    When very few samples of a random quantity are available from a source distribution of unknown shape, it is usually not possible to accurately infer the exact distribution from which the data samples come. Under-estimation of important quantities such as response variance and failure probabilities can result. For many engineering purposes, including design and risk analysis, we attempt to avoid under-estimation with a strategy to conservatively estimate (bound) these types of quantities -- without being overly conservative -- when only a few samples of a random quantity are available from model predictions or replicate experiments. This report examines a class of related sparse-data uncertainty representation and inference approaches that are relatively simple, inexpensive, and effective. Tradeoffs between the methods' conservatism, reliability, and risk versus number of data samples (cost) are quantified with multi-attribute metrics use d to assess method performance for conservative estimation of two representative quantities: central 95% of response; and 10-4 probability of exceeding a response threshold in a tail of the distribution. Each method's performance is characterized with 10,000 random trials on a large number of diverse and challenging distributions. The best method and number of samples to use in a given circumstance depends on the uncertainty quantity to be estimated, the PDF character, and the desired reliability of bounding the true value. On the basis of this large data base and study, a strategy is proposed for selecting the method and number of samples for attaining reasonable credibility levels in bounding these types of quantities when sparse samples of random variables or functions are available from experiments or simulations.

  11. New simple method for fast and accurate measurement of volumes

    International Nuclear Information System (INIS)

    Frattolillo, Antonio

    2006-01-01

    A new simple method is presented, which allows us to measure in just a few minutes but with reasonable accuracy (less than 1%) the volume confined inside a generic enclosure, regardless of the complexity of its shape. The technique proposed also allows us to measure the volume of any portion of a complex manifold, including, for instance, pipes and pipe fittings, valves, gauge heads, and so on, without disassembling the manifold at all. To this purpose an airtight variable volume is used, whose volume adjustment can be precisely measured; it has an overall capacity larger than that of the unknown volume. Such a variable volume is initially filled with a suitable test gas (for instance, air) at a known pressure, as carefully measured by means of a high precision capacitive gauge. By opening a valve, the test gas is allowed to expand into the previously evacuated unknown volume. A feedback control loop reacts to the resulting finite pressure drop, thus contracting the variable volume until the pressure exactly retrieves its initial value. The overall reduction of the variable volume achieved at the end of this process gives a direct measurement of the unknown volume, and definitively gets rid of the problem of dead spaces. The method proposed actually does not require the test gas to be rigorously held at a constant temperature, thus resulting in a huge simplification as compared to complex arrangements commonly used in metrology (gas expansion method), which can grant extremely accurate measurement but requires rather expensive equipments and results in time consuming methods, being therefore impractical in most applications. A simple theoretical analysis of the thermodynamic cycle and the results of experimental tests are described, which demonstrate that, in spite of its simplicity, the method provides a measurement accuracy within 0.5%. The system requires just a few minutes to complete a single measurement, and is ready immediately at the end of the process. The

  12. MÉTODO SIMPLES PARA ESTIMAR ENCURTAMENTO PELO FRIO EM CARNE BOVINA A SIMPLE METHOD TO ESTIMATE COLD SHORTENING IN BEEF

    Directory of Open Access Journals (Sweden)

    Riana Jordão Barrozo Heinemann

    2002-04-01

    Full Text Available É bem conhecido o fato de que o encurtamento pelo frio pode influenciar negativamente a textura da carne. Por isso, a determinação do grau de contração do tecido muscular é um recurso analítico de grande importância quando se estuda a otimização dos procedimentos industriais. Neste trabalho, foram avaliadas comparativamente duas metodologias de microscopia. Para isso, os músculos Biceps femoris, Longissimus dorsi e Semimembranosus obtidos de nove carcaças bovinas com três diferentes graus de acabamento foram analisados de forma pareada por ambos os métodos. O músculo Longissimus dorsi apresentou menor comprimento de sarcômero e o m. Semimembranosus o maior (p0,05, revelando a possibilidade de emprego do método mais simples.The negative influence of cold shortening on meat texture is well known. Because of that, the determination of the muscle contraction extent represents an important analytical tool for the optimization of the industrial procedures. In this work, two methodologies to evaluate cold shortening were compared. Biceps femoris, Longissimus dorsi and Semimembranosus muscles from 9 cattle carcasses with three different fat thickness grades were paired analyzed by both methodologies. Longissimus dorsi muscle showed the shortest sarcomere length while Semimembranosus m. showed the longest one (p0.05, which suggests the possibility of using the simpler method for cold shortening evaluation.

  13. Simple and efficient machine learning frameworks for identifying protein-protein interaction relevant articles and experimental methods used to study the interactions.

    Science.gov (United States)

    Agarwal, Shashank; Liu, Feifan; Yu, Hong

    2011-10-03

    Protein-protein interaction (PPI) is an important biomedical phenomenon. Automatically detecting PPI-relevant articles and identifying methods that are used to study PPI are important text mining tasks. In this study, we have explored domain independent features to develop two open source machine learning frameworks. One performs binary classification to determine whether the given article is PPI relevant or not, named "Simple Classifier", and the other one maps the PPI relevant articles with corresponding interaction method nodes in a standardized PSI-MI (Proteomics Standards Initiative-Molecular Interactions) ontology, named "OntoNorm". We evaluated our system in the context of BioCreative challenge competition using the standardized data set. Our systems are amongst the top systems reported by the organizers, attaining 60.8% F1-score for identifying relevant documents, and 52.3% F1-score for mapping articles to interaction method ontology. Our results show that domain-independent machine learning frameworks can perform competitively well at the tasks of detecting PPI relevant articles and identifying the methods that were used to study the interaction in such articles. Simple Classifier is available at http://sourceforge.net/p/simpleclassify/home/ and OntoNorm at http://sourceforge.net/p/ontonorm/home/.

  14. A simple two-step method to fabricate highly transparent ITO/polymer nanocomposite films

    International Nuclear Information System (INIS)

    Liu, Haitao; Zeng, Xiaofei; Kong, Xiangrong; Bian, Shuguang; Chen, Jianfeng

    2012-01-01

    Highlights: ► A simple two-step method without further surface modification step was employed. ► ITO nanoparticles were easily to be uniformly dispersed in polymer matrix. ► ITO/polymer nanocomposite film had high transparency and UV/IR blocking properties. - Abstract: Transparent functional indium tin oxide (ITO)/polymer nanocomposite films were fabricated via a simple approach with two steps. Firstly, the functional monodisperse ITO nanoparticles were synthesized via a facile nonaqueous solvothermal method using bifunctional chemical agent (N-methyl-pyrrolidone, NMP) as the reaction solvent and surface modifier. Secondly, the ITO/acrylics polyurethane (PUA) nanocomposite films were fabricated by a simple sol-solution mixing method without any further surface modification step as often employed traditionally. Flower-like ITO nanoclusters with about 45 nm in diameter were mono-dispersed in ethyl acetate and each nanocluster was assembled by nearly spherical nanoparticles with primary size of 7–9 nm in diameter. The ITO nanoclusters exhibited an excellent dispersibility in polymer matrix of PUA, remaining their original size without any further agglomeration. When the loading content of ITO nanoclusters reached to 5 wt%, the transparent functional nanocomposite film featured a high transparency more than 85% in the visible light region (at 550 nm), meanwhile cutting off near-infrared radiation about 50% at 1500 nm and blocking UV ray about 45% at 350 nm. It could be potential for transparent functional coating materials applications.

  15. Method for evaluation of radiative properties of glass samples

    Energy Technology Data Exchange (ETDEWEB)

    Mohelnikova, Jitka [Faculty of Civil Engineering, Brno University of Technology, Veveri 95, 602 00 Brno (Czech Republic)], E-mail: mohelnikova.j@fce.vutbr.cz

    2008-04-15

    The paper presents a simple calculation method which serves for an evaluation of radiative properties of window glasses. The method is based on a computer simulation model of the energy balance of a thermally insulated box with selected glass samples. A temperature profile of the air inside of the box with a glass sample exposed to affecting radiation was determined for defined boundary conditions. The spectral range of the radiation was considered in the interval between 280 and 2500 nm. This interval is adequate to the spectral range of solar radiation affecting windows in building facades. The air temperature rise within the box was determined in a response to the affecting radiation in the time between the beginning of the radiation exposition and the time of steady-state thermal conditions. The steady state temperature inside of the insulated box serves for the evaluation of the box energy balance and determination of the glass sample radiative properties. These properties are represented by glass characteristics as mean values of transmittance, reflectance and absorptance calculated for a defined spectral range. The data of the computer simulations were compared to experimental measurements on a real model of the insulated box. Results of both the calculations and measurements are in a good compliance. The method is recommended for preliminary evaluation of window glass radiative properties which serve as data for energy evaluation of buildings.

  16. A simple and rapid method of purification of impure plutonium oxide

    International Nuclear Information System (INIS)

    Michael, K.M.; Rakshe, P.R.; Dharmpurikar, G.R.; Thite, B.S.; Lokhande, Manisha; Sinalkar, Nitin; Dakshinamoorthy, A.; Munshi, S.K.; Dey, P.K.

    2007-01-01

    Impure plutonium oxides are conventionally purified by dissolution in HNO 3 in presence of HF followed by ion exchange separation and oxalate precipitation. The method is tedious and use of HF enhances corrosion of the plant equipment's. A simple and rapid method has been developed for the purification of the oxide by leaching with various reagents like DM water, NaOH and oxalic acid. A combination of DM water followed by hot leaching with 0.4 M oxalic acid could bring down the impurity levels in the oxide to the desired level required for fuel fabrication. (author)

  17. A simple method for percutaneous resection of osteoid osteoma

    International Nuclear Information System (INIS)

    Kamrani, Reza S.; Kiani, K.; Mazlouman, Shahriar J.

    2007-01-01

    To introduce a method that can be performed with minimal equipments available to most orthopedic surgeons and precludes the extensive anesthetic and ablative requirements. A percutaneous lead tunnel was first established in the cortex next to the nidus under computerized tomography guidance with local anesthesia; then the nidus was curetted in the operating room through the lead tunnel. The study was performed in Shariati Hospital in Tehran, Iran, from September 2002 to December 2005. Nineteen patients were treated with this method with 94.7% cure rate. The diagnosis was histologically confirmed in 16 cases (84.2%). Failure occurred in one patient. The patients had a mean follow-up of 13.5 months with no recurrence of symptoms with mean hospitalization time of 1.6 days. This technique is simple, minimally invasive and effective. It needs no especial equipments and provides the material for tissue diagnosis. (author)

  18. Scintigraphic method for evaluating reductions in local blood volumes in human extremities

    DEFF Research Database (Denmark)

    Blønd, L; Madsen, Jan Lysgård

    2000-01-01

    in the experiment. Evaluation of one versus two scintigraphic projections, trials for assessment of the reproducibility, a comparison of the scintigraphic method with a water-plethysmographic method and registration of the fractional reduction in blood volume caused by exsanguination as a result of simple elevation......% in the lower limb experiment and 6% in the upper limb experiment. We found a significant relation (r = 0.42, p = 0.018) between the results obtained by the scintigraphic method and the plethysmographic method. In fractions, a mean reduction in blood volume of 0.49+0.14 (2 SD) was found after 1 min of elevation......We introduce a new method for evaluating reductions in local blood volumes in extremities, based on the combined use of autologue injection of 99mTc-radiolabelled erythrocytes and clamping of the limb blood flow by the use of a tourniquet. Twenty-two healthy male volunteers participated...

  19. A multi-criteria evaluation method for climate change mitigation policy instruments

    International Nuclear Information System (INIS)

    Konidari, Popi; Mavrakis, Dimitrios

    2007-01-01

    This paper presents an integrated multi-criteria analysis method for the quantitative evaluation of climate change mitigation policy instruments. The method consists of: (i) a set of criteria supported by sub-criteria, all of which describe the complex framework under which these instruments are selected by policy makers and implemented, (ii) an Analytical Hierarchy Process (AHP) process for defining weight coefficients for criteria and sub-criteria according to the preferences of three stakeholders groups and (iii) a Multi-Attribute Theory (MAUT)/Simple Multi-Attribute Ranking Technique (SMART) process for assigning grades to each instrument that is evaluated for its performance under a specific sub-criterion. Arguments for the selected combination of these standard methods and definitions for criteria/sub-criteria are quoted. Consistency and robustness tests are performed. The functionality of the proposed method is tested by assessing the aggregate performances of the EU emission trading scheme at Denmark, Germany, Greece, Italy, Netherlands, Portugal, Sweden and United Kingdom. Conclusions are discussed

  20. A simple scintigraphic method for continuous monitoring of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Lipp, R.W.; Hammer, H.F.; Schnedl, W.; Dobnig, H.; Passath, A.; Leb, G.; Krejs, G.J. (Graz Univ. (Austria). Div. of Nuclear Medicine and Endocrinology)

    1993-03-01

    A new and simple scintigraphic method for the measurement of gastric emptying was developed and validated. The test meal consists of 200 g potato mash mixed with 0.5 g Dowex 2X8 particles (mesh 20-50) labelled with 37 MBq (1 mCi) technetium-99m. After ingestion of the meal, sequential dynamic 15-s anteroposterior exposures in the supine position are obtained for 90 min. A second recording sequence of 20 min is added after a 30-min interval. The results can be displayed as immediate cine-replay, as time-activity diagrams and/or as acitivty retention values. Complicated mathematical fittings are not necessary. The method lends itself equally to the testing of in- and outpatients. (orig.).

  1. A simple method for the preparation of difficult 99mTc complexes using surface adsorbed stannous ions

    International Nuclear Information System (INIS)

    Maddalena, D.J.; Snowdon, G.M.; Pojer, P.M.

    1987-01-01

    A simple new technique where stannous tin is adsorbed on the inner surface of plastic tubing and used to reduce ( 99m Tc) pertechnetate prior to labelling radiopharmaceuticals, has been evaluated, using some lipophillic and metal containing ligands. Complexes formed using the technique had good labelling efficiency and behaved the same in rat biodistribution studies as those prepared using conventional labelling methods. The labelling efficiency of the ligands was not related to their lipophillicity suggesting that this technique may be useful for labelling lipophillic and other difficult ligands such as those containing metals, which are incompatible with free stannous ions in solution. (M.E.L.) [es

  2. USING OF MULTI-CRITERIAL EVALUATION METHODS TO ASSESS POSITION OF THE OBJECT IN THE MARKET

    Directory of Open Access Journals (Sweden)

    Gabriela Ižaríková

    2014-09-01

    Full Text Available The article deals with the evaluation of the firm's position. Recognition of market position among competitors but also among customers is important for the development of the company. A comparison can be made by using multicriterial methods. The ranking of companies is based on different methods (method of simple order, weighted order sum method, point methods, standardized variable method. Compliance order will be assessed by the rank correlation coefficients. Acquired assessment of market state allows us to design a strategic.

  3. A simple optical method for measuring the vibration amplitude of a speaker

    OpenAIRE

    UEDA, Masahiro; YAMAGUCHI, Toshihiko; KAKIUCHI, Hiroki; SUGA, Hiroshi

    1999-01-01

    A simple optical method has been proposed for measuring the vibration amplitude of a speaker vibrating with a frequency of approximately 10 kHz. The method is based on a multiple reflection between a vibrating speaker plane and a mirror parallel to that speaker plane. The multiple reflection can magnify a dispersion of the laser beam caused by the vibration, and easily make a measurement of the amplitude. The measuring sensitivity ranges between sub-microns and 1 mm. A preliminary experim...

  4. A simple method to downscale daily wind statistics to hourly wind data

    OpenAIRE

    Guo, Zhongling

    2013-01-01

    Wind is the principal driver in the wind erosion models. The hourly wind speed data were generally required for precisely wind erosion modeling. In this study, a simple method to generate hourly wind speed data from daily wind statistics (daily average and maximum wind speeds together or daily average wind speed only) was established. A typical windy location with 3285 days (9 years) measured hourly wind speed data were used to validate the downscaling method. The results showed that the over...

  5. Simulation Opportunity Index, A Simple and Effective Method to Boost the Hydrocarbon Recovery

    KAUST Repository

    Saputra, Wardana

    2016-01-01

    This paper describes how the SOI software helps as a simple, fast, and accurate way to obtain the higher hydrocarbon production than that of trial-error method and previous studies in two different fields located in offshore Indonesia. On one hand, the proposed method could save money by minimizing the required number of wells. On the other hand, it could maximize profit by maximizing recovery.

  6. Rapid and simple colorimetric method for the quantification of AI-2 produced from Salmonella Typhimurium.

    Science.gov (United States)

    Wattanavanitchakorn, Siriluck; Prakitchaiwattana, Cheunjit; Thamyongkit, Patchanita

    2014-04-01

    The aim of this study was to evaluate the feasibility of Fe(III) ion reduction for the simple and rapid quantification of autoinducer-2 (AI-2) produced from bacteria using Salmonella Typhimurium as a model. Since the molecular structure of AI-2 is somewhat similar to ascorbic acid it was expected that AI-2 would also act as a reducing agent and reduce Fe(III) ions in the presence of 1,10-phenanthroline to form the colored [(o-phen)3 Fe(II)]SO4 ferroin complex that could be quantified colorimetrically. In support of this, colony rinses and cell free supernatants from cultures of all tested AI-2 producing strains, but not the AI-2 negative Sinorhizobium meliloti, formed a colored complex with a λmax of 510nm. The OD510 values of these culture supernatants or colony rinses were in broad agreement with the % activity observed in the same samples using the standard Vibrio harveyi bioluminescence assay for AI-2 detection, and with previously reported results. This methodology could potentially be developed as an alternative method for the simple and rapid quantification of AI-2 levels produced in bacterial cultures. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Comparison of simple additive weighting (SAW) and composite performance index (CPI) methods in employee remuneration determination

    Science.gov (United States)

    Karlitasari, L.; Suhartini, D.; Benny

    2017-01-01

    The process of determining the employee remuneration for PT Sepatu Mas Idaman currently are still using Microsoft Excel-based spreadsheet where in the spreadsheet there is the value of criterias that must be calculated for every employee. This can give the effect of doubt during the assesment process, therefore resulting in the process to take much longer time. The process of employee remuneration determination is conducted by the assesment team based on some criterias that have been predetermined. The criteria used in the assessment process are namely the ability to work, human relations, job responsibility, discipline, creativity, work, achievement of targets, and absence. To ease the determination of employee remuneration to be more efficient and effective, the Simple Additive Weighting (SAW) method is used. SAW method can help in decision making for a certain case, and the calculation that generates the greatest value will be chosen as the best alternative. Other than SAW, also by using another method was the CPI method which is one of the calculating method in decision making based on performance index. Where SAW method was more faster by 89-93% compared to CPI method. Therefore it is expected that this application can be an evaluation material for the need of training and development for employee performances to be more optimal.

  8. A simple method for HPLC retention time prediction: linear calibration using two reference substances.

    Science.gov (United States)

    Sun, Lei; Jin, Hong-Yu; Tian, Run-Tao; Wang, Ming-Juan; Liu, Li-Na; Ye, Liu-Ping; Zuo, Tian-Tian; Ma, Shuang-Cheng

    2017-01-01

    Analysis of related substances in pharmaceutical chemicals and multi-components in traditional Chinese medicines needs bulk of reference substances to identify the chromatographic peaks accurately. But the reference substances are costly. Thus, the relative retention (RR) method has been widely adopted in pharmacopoeias and literatures for characterizing HPLC behaviors of those reference substances unavailable. The problem is it is difficult to reproduce the RR on different columns due to the error between measured retention time (t R ) and predicted t R in some cases. Therefore, it is useful to develop an alternative and simple method for prediction of t R accurately. In the present study, based on the thermodynamic theory of HPLC, a method named linear calibration using two reference substances (LCTRS) was proposed. The method includes three steps, procedure of two points prediction, procedure of validation by multiple points regression and sequential matching. The t R of compounds on a HPLC column can be calculated by standard retention time and linear relationship. The method was validated in two medicines on 30 columns. It was demonstrated that, LCTRS method is simple, but more accurate and more robust on different HPLC columns than RR method. Hence quality standards using LCTRS method are easy to reproduce in different laboratories with lower cost of reference substances.

  9. A method to evaluate relative ovicidal effects of soil microfungi on thick-shelled eggs of animal-parasitic nematodes

    DEFF Research Database (Denmark)

    Thapa, Sundar; Meyling, Nicolai Vitt; Katakam, Kiran Kumar

    2015-01-01

    Thick-shelled eggs of animal-parasitic ascarid nematodes can survive and remain infective in the environment for years. The present study evaluated a simple in vitro method and evaluation scheme to assess the relative effect of two species of soil microfungi, Pochonia chlamydosporia Biotype 10...

  10. Wrist arthrography: a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Berna-Serna, Juan D.; Reus, Manuel; Alonso, Jose [Virgen de la Arrixaca University Hospital, Department of Radiology, El Palmar (Murcia) (Spain); Martinez, Francisco; Domenech-Ratto, Gines [University of Murcia, Department of Human Anatomy, Faculty of Medicine, Murcia (Spain)

    2006-02-01

    A technique of wrist arthrography is presented using an adhesive marker-plate with radiopaque coordinates to identify precisely sites for puncture arthrography of the wrist and to obviate the need for fluoroscopic guidance. Radiocarpal joint arthrography was performed successfully in all 24 cases, 14 in the cadaveric wrists and 10 in the live patients. The arthrographic procedure described in this study is simple, safe, and rapid, and has the advantage of precise localisation of the site for puncture without need for fluoroscopic guidance. (orig.)

  11. A simple labeled test meal for the evaluation of gastric emptying

    Energy Technology Data Exchange (ETDEWEB)

    Ishii, Keita; Tanabe, Satoshi; Mitsuhashi, Toshiharu; Saigenji, Katsunori [Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine

    1994-10-01

    We developed a simple test meal for the evaluation of gastric emptying. Preparation of a test meal for routine clinical use in institutions should be as simple as possible. The newly developed test meal consists of instant noodles labeled with 37 MBq (1 mCi) technetium-99m and does not require the use of cooking utensils. The test meal was given with drinking water (180 ml) to healthy adult volunteers (6 men, 34.5[+-]2.2 years old) and gastric emptying was measured at 0, 5, 10, 15, 30, 45, 60, 80, 100, 120 minutes after the end of the meal, and results were compared with those derived without drinking water. The emptying pattern of the test meal with water exhibited an exponential pattern typical of a liquid meal, and that without water formed a linear pattern after an initial lag phase in keeping with gastric emptying of a solid meal. In addition, the test meal was given to 11 patients of diabetic gastroparesis (5 men, 6 women, 50.4[+-]4.5 years old), and gastric emptying was measured. At each period evaluated, emptying was significantly slower in diabetic gastroparesis than in healthy controls (6 men, 1 woman, 32.1[+-]3.0 years old). These results show that the test meal is reliable and applicable to the clinical assessment of gastric emptying, while fulfilling the need for simplicity. (author).

  12. Filtration Isolation of Nucleic Acids: A Simple and Rapid DNA Extraction Method.

    Science.gov (United States)

    McFall, Sally M; Neto, Mário F; Reed, Jennifer L; Wagner, Robin L

    2016-08-06

    FINA, filtration isolation of nucleic acids, is a novel extraction method which utilizes vertical filtration via a separation membrane and absorbent pad to extract cellular DNA from whole blood in less than 2 min. The blood specimen is treated with detergent, mixed briefly and applied by pipet to the separation membrane. The lysate wicks into the blotting pad due to capillary action, capturing the genomic DNA on the surface of the separation membrane. The extracted DNA is retained on the membrane during a simple wash step wherein PCR inhibitors are wicked into the absorbent blotting pad. The membrane containing the entrapped DNA is then added to the PCR reaction without further purification. This simple method does not require laboratory equipment and can be easily implemented with inexpensive laboratory supplies. Here we describe a protocol for highly sensitive detection and quantitation of HIV-1 proviral DNA from 100 µl whole blood as a model for early infant diagnosis of HIV that could readily be adapted to other genetic targets.

  13. Systematic Evaluation of Methods for Integration of Transcriptomic Data into Constraint-Based Models of Metabolism

    DEFF Research Database (Denmark)

    Machado, Daniel; Herrgard, Markus

    2014-01-01

    of these methods has not been critically evaluated and compared. This work presents a survey of recently published methods that use transcript levels to try to improve metabolic flux predictions either by generating flux distributions or by creating context-specific models. A subset of these methods...... is then systematically evaluated using published data from three different case studies in E. coli and S. cerevisiae. The flux predictions made by different methods using transcriptomic data are compared against experimentally determined extracellular and intracellular fluxes (from 13C-labeling data). The sensitivity...... of the results to method-specific parameters is also evaluated, as well as their robustness to noise in the data. The results show that none of the methods outperforms the others for all cases. Also, it is observed that for many conditions, the predictions obtained by simple flux balance analysis using growth...

  14. Sensitive and simple method for measuring wire tensions

    International Nuclear Information System (INIS)

    Atac, M.; Mishina, M.

    1982-08-01

    Measuring tension of wires in drift chambers and multiwire proportional chambers after construction is an important process because sometimes wires get loose after soldering, crimping or glueing. One needs to sort out wires which have tensions below a required minimum value to prevent electrostatic instabilities. There have been several methods reported on this subject in which the wires were excited either with sinusoidal current under magnetic field or with sinusoidal voltage electrostatically coupled to the wire, searching for a resonating frequency with which the wires vibrate mechanically. Then the vibration is detected either visually, optically or with magnetic pick-up directly touching the wires. Any of these is only applicable to the usual multiwire chamber which has open access to the wire plane. They also need fairly large excitation currents to induce a detectable vibration to the wires. Here we report a very simple method that can be used for any type of wire chamber or proportional tube system for measuring wire tension. Only a very small current is required for the wire excitation to obtain a large enough signal because it detects the induced emf voltage across a wire. A sine-wave oscillator and a digital voltmeter are sufficient devices aside from a permanent magnet to provide the magnetic field around the wire. A useful application of this method to a large system is suggested

  15. Fast and Simple Analytical Method for Direct Determination of Total Chlorine Content in Polyglycerol by ICP-MS.

    Science.gov (United States)

    Jakóbik-Kolon, Agata; Milewski, Andrzej; Dydo, Piotr; Witczak, Magdalena; Bok-Badura, Joanna

    2018-02-23

    The fast and simple method for total chlorine determination in polyglycerols using low resolution inductively coupled plasma mass spectrometry (ICP-MS) without the need for additional equipment and time-consuming sample decomposition was evaluated. Linear calibration curve for 35 Cl isotope in the concentration range 20-800 µg/L was observed. Limits of detection and quantification equaled to 15 µg/L and 44 µg/L, respectively. This corresponds to possibility of detection 3 µg/g and determination 9 µg/g of chlorine in polyglycerol using studied conditions (0.5% matrix-polyglycerol samples diluted or dissolved with water to an overall concentration of 0.5%). Matrix effects as well as the effect of chlorine origin have been evaluated. The presence of 0.5% (m/m) of matrix species similar to polyglycerol (polyethylene glycol-PEG) did not influence the chlorine determination for PEGs with average molecular weights (MW) up to 2000 Da. Good precision and accuracy of the chlorine content determination was achieved regardless on its origin (inorganic/organic). High analyte recovery level and low relative standard deviation values were observed for real polyglycerol samples spiked with chloride. Additionally, the Combustion Ion Chromatography System was used as a reference method. The results confirmed high accuracy and precision of the tested method.

  16. A Simple yet Accurate Method for the Estimation of the Biovolume of Planktonic Microorganisms.

    Science.gov (United States)

    Saccà, Alessandro

    2016-01-01

    Determining the biomass of microbial plankton is central to the study of fluxes of energy and materials in aquatic ecosystems. This is typically accomplished by applying proper volume-to-carbon conversion factors to group-specific abundances and biovolumes. A critical step in this approach is the accurate estimation of biovolume from two-dimensional (2D) data such as those available through conventional microscopy techniques or flow-through imaging systems. This paper describes a simple yet accurate method for the assessment of the biovolume of planktonic microorganisms, which works with any image analysis system allowing for the measurement of linear distances and the estimation of the cross sectional area of an object from a 2D digital image. The proposed method is based on Archimedes' principle about the relationship between the volume of a sphere and that of a cylinder in which the sphere is inscribed, plus a coefficient of 'unellipticity' introduced here. Validation and careful evaluation of the method are provided using a variety of approaches. The new method proved to be highly precise with all convex shapes characterised by approximate rotational symmetry, and combining it with an existing method specific for highly concave or branched shapes allows covering the great majority of cases with good reliability. Thanks to its accuracy, consistency, and low resources demand, the new method can conveniently be used in substitution of any extant method designed for convex shapes, and can readily be coupled with automated cell imaging technologies, including state-of-the-art flow-through imaging devices.

  17. A Simple yet Accurate Method for the Estimation of the Biovolume of Planktonic Microorganisms.

    Directory of Open Access Journals (Sweden)

    Alessandro Saccà

    Full Text Available Determining the biomass of microbial plankton is central to the study of fluxes of energy and materials in aquatic ecosystems. This is typically accomplished by applying proper volume-to-carbon conversion factors to group-specific abundances and biovolumes. A critical step in this approach is the accurate estimation of biovolume from two-dimensional (2D data such as those available through conventional microscopy techniques or flow-through imaging systems. This paper describes a simple yet accurate method for the assessment of the biovolume of planktonic microorganisms, which works with any image analysis system allowing for the measurement of linear distances and the estimation of the cross sectional area of an object from a 2D digital image. The proposed method is based on Archimedes' principle about the relationship between the volume of a sphere and that of a cylinder in which the sphere is inscribed, plus a coefficient of 'unellipticity' introduced here. Validation and careful evaluation of the method are provided using a variety of approaches. The new method proved to be highly precise with all convex shapes characterised by approximate rotational symmetry, and combining it with an existing method specific for highly concave or branched shapes allows covering the great majority of cases with good reliability. Thanks to its accuracy, consistency, and low resources demand, the new method can conveniently be used in substitution of any extant method designed for convex shapes, and can readily be coupled with automated cell imaging technologies, including state-of-the-art flow-through imaging devices.

  18. Reliability Evaluation of Bridges Based on Nonprobabilistic Response Surface Limit Method

    Directory of Open Access Journals (Sweden)

    Xuyong Chen

    2017-01-01

    Full Text Available Due to many uncertainties in nonprobabilistic reliability assessment of bridges, the limit state function is generally unknown. The traditional nonprobabilistic response surface method is a lengthy and oscillating iteration process and leads to difficultly solving the nonprobabilistic reliability index. This article proposes a nonprobabilistic response surface limit method based on the interval model. The intention of this method is to solve the upper and lower limits of the nonprobabilistic reliability index and to narrow the range of the nonprobabilistic reliability index. If the range of the reliability index reduces to an acceptable accuracy, the solution will be considered convergent, and the nonprobabilistic reliability index will be obtained. The case study indicates that using the proposed method can avoid oscillating iteration process, make iteration process stable and convergent, reduce iteration steps significantly, and improve computational efficiency and precision significantly compared with the traditional nonprobabilistic response surface method. Finally, the nonprobabilistic reliability evaluation process of bridge will be built through evaluating the reliability of one PC continuous rigid frame bridge with three spans using the proposed method, which appears to be more simple and reliable when lack of samples and parameters in the bridge nonprobabilistic reliability evaluation is present.

  19. Study on the evaluation method of radiation dose rate around spent fuel shipping casks

    International Nuclear Information System (INIS)

    Yamakoshi, Hisao

    1986-01-01

    This study aims at developing a simple calculation method which can evaluate radiation dose rate around casks with high accuracy in a short time. The method is based on a concept of the radiation shielding characteristics of cask walls. The concept was introduced to replace for ordinary radiation shielding calculation which requires a long calculation time and a large memory capacity of a computer in the matrix calculation. For the purpose of verifying the accuracy and reliability of the new method, it was applied to the analysis of the dose rate distribution around actual casks, which had been measured. The results of the analysis revealed that the newly proposed method was excellent for the forecast of radiation dose rate distribution around casks in view of the accuracy and calculation time. The short calculation time and high accuracy by the proposed method were attained by dividing the whole procedure of ordinary fine radiation shielding calculation into the calculation of radiation dose rate on a cask surface by the matrix expression of the characteristic function and the calculation of dose rate distribution using the simple analytical expression of dose rate distribution around casks. The effect of the heterogeneous array of spent fuel in different burnup state on dose rate distribution around casks was evaluated by this method. (Kako, I.)

  20. A simple headspace equilibration method for measuring dissolved methane

    Science.gov (United States)

    Magen, C; Lapham, L.L.; Pohlman, John W.; Marshall, Kristin N.; Bosman, S.; Casso, Michael; Chanton, J.P.

    2014-01-01

    Dissolved methane concentrations in the ocean are close to equilibrium with the atmosphere. Because methane is only sparingly soluble in seawater, measuring it without contamination is challenging for samples collected and processed in the presence of air. Several methods for analyzing dissolved methane are described in the literature, yet none has conducted a thorough assessment of the method yield, contamination issues during collection, transport and storage, and the effect of temperature changes and preservative. Previous extraction methods transfer methane from water to gas by either a "sparge and trap" or a "headspace equilibration" technique. The gas is then analyzed for methane by gas chromatography. Here, we revisit the headspace equilibration technique and describe a simple, inexpensive, and reliable method to measure methane in fresh and seawater, regardless of concentration. Within the range of concentrations typically found in surface seawaters (2-1000 nmol L-1), the yield of the method nears 100% of what is expected from solubility calculation following the addition of known amount of methane. In addition to being sensitive (detection limit of 0.1 ppmv, or 0.74 nmol L-1), this method requires less than 10 min per sample, and does not use highly toxic chemicals. It can be conducted with minimum materials and does not require the use of a gas chromatograph at the collection site. It can therefore be used in various remote working environments and conditions.

  1. Machine learning plus optical flow: a simple and sensitive method to detect cardioactive drugs

    Science.gov (United States)

    Lee, Eugene K.; Kurokawa, Yosuke K.; Tu, Robin; George, Steven C.; Khine, Michelle

    2015-07-01

    Current preclinical screening methods do not adequately detect cardiotoxicity. Using human induced pluripotent stem cell-derived cardiomyocytes (iPS-CMs), more physiologically relevant preclinical or patient-specific screening to detect potential cardiotoxic effects of drug candidates may be possible. However, one of the persistent challenges for developing a high-throughput drug screening platform using iPS-CMs is the need to develop a simple and reliable method to measure key electrophysiological and contractile parameters. To address this need, we have developed a platform that combines machine learning paired with brightfield optical flow as a simple and robust tool that can automate the detection of cardiomyocyte drug effects. Using three cardioactive drugs of different mechanisms, including those with primarily electrophysiological effects, we demonstrate the general applicability of this screening method to detect subtle changes in cardiomyocyte contraction. Requiring only brightfield images of cardiomyocyte contractions, we detect changes in cardiomyocyte contraction comparable to - and even superior to - fluorescence readouts. This automated method serves as a widely applicable screening tool to characterize the effects of drugs on cardiomyocyte function.

  2. A method of rapidly evaluating image quality of NED optical system

    Science.gov (United States)

    Sun, Qi; Qiu, Chuankai; Yang, Huan

    2014-11-01

    In recent years, with the development of technology of micro-display, advanced optics and the software and hardware, near-to-eye display ( NED) optical system will have a wide range of potential applications in the fields of amusement and virtual reality. However, research on the evaluating image quality of this kind optical system is comparatively lagging behind. Although now there are some methods and equipment for evaluation, they can't be applied in commercial production because of their complex operation and inaccuracy. In this paper, an academic method is proposed and a Rapid Evaluation System (RES) is designed to evaluate the image of optical system rapidly and exactly. Firstly, a set of parameters that eyes are sensitive to and also express the quality of system should be extracted and quantized to be criterion, so the evaluation standards can be established. Then, some parameters can be detected by RES consisted of micro-display, CCD camera and computer and so on. By process of scaling, the measuring results of the RES are exact and creditable, relationship between object measurement, subjective evaluation and the RES will be established. After that, image quality of optical system can be evaluated just by detecting parameters of that. The RES is simple and the results of evaluation are exact and keeping with human vision. So the method can be used not only for optimizing design of optical system, but also for evaluation in commercial production.

  3. A simple and inexpensive method for genomic restriction mapping analysis

    International Nuclear Information System (INIS)

    Huang, C.H.; Lam, V.M.S.; Tam, J.W.O.

    1988-01-01

    The Southern blotting procedure for the transfer of DNA fragments from agarose gels to nitrocellulose membranes has revolutionized nucleic acid detection methods, and it forms the cornerstone of research in molecular biology. Basically, the method involves the denaturation of DNA fragments that have been separated on an agarose gel, the immobilization of the fragments by transfer to a nitrocellulose membrane, and the identification of the fragments of interest through hybridization to /sup 32/P-labeled probes and autoradiography. While the method is sensitive and applicable to both genomic and cloned DNA, it suffers from the disadvantages of being time consuming and expensive, and fragments of greater than 15 kb are difficult to transfer. Moreover, although theoretically the nitrocellulose membrane can be washed and hybridized repeatedly using different probes, in practice, the membrane becomes brittle and difficult to handle after a few cycles. A direct hybridization method for pure DNA clones was developed in 1975 but has not been widely exploited. The authors report here a modification of their procedure as applied to genomic DNA. The method is simple, rapid, and inexpensive, and it does not involve transfer to nitrocellulose membranes

  4. A Novel Method for the Accurate Evaluation of Poisson’s Ratio of Soft Polymer Materials

    Directory of Open Access Journals (Sweden)

    Jae-Hoon Lee

    2013-01-01

    Full Text Available A new method with a simple algorithm was developed to accurately measure Poisson’s ratio of soft materials such as polyvinyl alcohol hydrogel (PVA-H with a custom experimental apparatus consisting of a tension device, a micro X-Y stage, an optical microscope, and a charge-coupled device camera. In the proposed method, the initial positions of the four vertices of an arbitrarily selected quadrilateral from the sample surface were first measured to generate a 2D 1st-order 4-node quadrilateral element for finite element numerical analysis. Next, minimum and maximum principal strains were calculated from differences between the initial and deformed shapes of the quadrilateral under tension. Finally, Poisson’s ratio of PVA-H was determined by the ratio of minimum principal strain to maximum principal strain. This novel method has an advantage in the accurate evaluation of Poisson’s ratio despite misalignment between specimens and experimental devices. In this study, Poisson’s ratio of PVA-H was 0.44 ± 0.025 (n=6 for 2.6–47.0% elongations with a tendency to decrease with increasing elongation. The current evaluation method of Poisson’s ratio with a simple measurement system can be employed to a real-time automated vision-tracking system which is used to accurately evaluate the material properties of various soft materials.

  5. Simple Evaluation of Load-Carrying Capacity of Multi-Span Folding Bridges based on Floating Supports

    Directory of Open Access Journals (Sweden)

    Jan Marszałek

    2014-12-01

    Full Text Available [b]Abstract[/b]. The papers covers simple evaluation of load-carrying capacity of multi-span folding bridges based on floating supports. Combined bridges built in this approach, could be used as a temporary crossing. The methodology of this evaluation is shown graphically on the basis of designed nomograms for two existing bridge structures i.e. MS-54 and DMS-65, mounted on rigid and floating supports. These nomograms facilitate the simple and fast determination of the impact of changing fixed support into floating support with different bridge length spans on the carrying capacity of the bridge. The paper also presents the influence of long-term use (enlarging the mounting backlash in the joints of these structures on the carrying capacity of the bridge.[b]Keywords[/b]: building, folding bridges, nomograms, assembly clearances

  6. A Simple Method for Measuring the Verticality of Small-Diameter Driven Wells

    DEFF Research Database (Denmark)

    Kjeldsen, Peter; Skov, Bent

    1994-01-01

    The presence of stones, solid waste, and other obstructions can deflect small-diameter driven wells during installation, leading to deviations of the well from its intended position. This could lead to erroneous results, especially for measurements of ground water levels by water level meters....... A simple method was developed to measure deviations from the intended positions of well screens and determine correction factors required for proper measurement of ground water levels in nonvertical wells. The method is based upon measurement of the hydrostatic pressure in the bottom of a water column...... ground water flow directions....

  7. A Nonmonotone Trust Region Method for Nonlinear Programming with Simple Bound Constraints

    International Nuclear Information System (INIS)

    Chen, Z.-W.; Han, J.-Y.; Xu, D.-C.

    2001-01-01

    In this paper we propose a nonmonotone trust region algorithm for optimization with simple bound constraints. Under mild conditions, we prove the global convergence of the algorithm. For the monotone case it is also proved that the correct active set can be identified in a finite number of iterations if the strict complementarity slackness condition holds, and so the proposed algorithm reduces finally to an unconstrained minimization method in a finite number of iterations, allowing a fast asymptotic rate of convergence. Numerical experiments show that the method is efficient

  8. Evaluation of generalized degrees of freedom for sparse estimation by replica method

    Science.gov (United States)

    Sakata, A.

    2016-12-01

    We develop a method to evaluate the generalized degrees of freedom (GDF) for linear regression with sparse regularization. The GDF is a key factor in model selection, and thus its evaluation is useful in many modelling applications. An analytical expression for the GDF is derived using the replica method in the large-system-size limit with random Gaussian predictors. The resulting formula has a universal form that is independent of the type of regularization, providing us with a simple interpretation. Within the framework of replica symmetric (RS) analysis, GDF has a physical meaning as the effective fraction of non-zero components. The validity of our method in the RS phase is supported by the consistency of our results with previous mathematical results. The analytical results in the RS phase are calculated numerically using the belief propagation algorithm.

  9. Method for evaluating operator inputs to digital controllers

    International Nuclear Information System (INIS)

    Venhuizen, J.R.

    1983-01-01

    Most industrial processes employ operator-interactive control systems. The performance of these control systems is influenced by the choice of control station (device through which operator enters control commands). While the importance of proper control-station selection is widely accepted, standard and simple selection methods are not available for the control station using color-graphics terminals. This paper describes a unique facility for evaluating the effectiveness of various control stations. In the facility, a process is simulated on a hybrid computer, color-graphics display terminals provide information to the operator, and different control stations accept input commands to control the simulation. Tests are being conducted to evaluate a keyboard, a graphics tablet, and a CRT touch panel for use as control stations on a nuclear power plant. Preliminary results indicate that our facility can be used to determine those situations where each type of station is advantageous

  10. Report of the methods for quantitative organ evaluation in nuclear medicine

    International Nuclear Information System (INIS)

    Nakata, Shigeru; Akagi, Naoki; Mimura, Hiroaki; Nagaki, Akio; Takahashi, Yasuyuki

    1999-01-01

    The group for the methods in the title herein reported the summary of their investigations on literatures concerning the brain, heart, liver and kidney evaluation. The report consisted of the history, kinetics of the agents, methods for quantitative evaluation and summary for each organ. As for the brain, the quantitative evaluation of cerebral blood flow scintigraphy with 123 I-IMP and 99m Tc-HMPAO or -ECD were reviewed to conclude that the present convenient methods are of problems in precision, for which a novel method and/or tracer should be developed. For cardiac functions, there is a method based either on the behavior of tracer in the blood which is excellent in reproducibility, or on the morphology of cardiac wall of which images can be analyzed alternatively by CT and MRI. For these, 131 I-albumin, 99m Tc-albumin, -red blood cells, -MIBI and -tetrofosmin have been used. For myocardium, 201 Tl has been used to evaluate the ischemic region and, with simultaneous use of 99m Tc-MIBI or -tetrofosmin, the viability. 123 I-BMIPP and -MIBG have been developed for myocardial fatty acid metabolism and for cardiac sympathetic nerve functions. Liver functions have been evaluated by the blood elimination rate, hepatic uptake, hepatic elimination and hepatic blood flow with use of 99m Tc-labeled colloids, -PMT and -GSA. Quantitative evaluation of renal functions is now well established with high precision since the kinetic behavior of the tracers, like 99m Tc-DTPA, -MAG3, -DMSA and 131 I-OIH, is simple. (K.H.)

  11. Simple probabilistic method for relative risk evaluation of nuclear terrorism events

    International Nuclear Information System (INIS)

    Zhang Songbai; Wu Jun

    2006-01-01

    On the basis of the event-tree and probability analysis methods, a probabilistic method of nuclear terrorism risk was built, and the risk of terrorism events was analyzed. With the statistical data for and hypothetical data for relative events, the relative probabilities of the four kinds of nuclear terrorism events were obtained, as well as the relative risks of these four kinds of nuclear terrorism events were calculated by using this probabilistic method. The illustrated case show that the descending sequence of damages from the four kinds of nuclear terrorism events for single event is as following: nuclear explosive and improvised nuclear explosive, nuclear facility attacked, and 'dirty bomb'. Under the hypothetical condition, the descending sequence of possibilities for the four kinds of nuclear terrorism events is as following: 'dirty bomb', nuclear facility attacked, improvised nuclear explosive and nuclear explosive, but the descending sequence of risks is as following: 'dirty bomb', improvised nuclear explosive, nuclear facility attacked, and nuclear explosive . (authors)

  12. A simple method of equine limb force vector analysis and its potential applications.

    Science.gov (United States)

    Hobbs, Sarah Jane; Robinson, Mark A; Clayton, Hilary M

    2018-01-01

    Ground reaction forces (GRF) measured during equine gait analysis are typically evaluated by analyzing discrete values obtained from continuous force-time data for the vertical, longitudinal and transverse GRF components. This paper describes a simple, temporo-spatial method of displaying and analyzing sagittal plane GRF vectors. In addition, the application of statistical parametric mapping (SPM) is introduced to analyse differences between contra-lateral fore and hindlimb force-time curves throughout the stance phase. The overall aim of the study was to demonstrate alternative methods of evaluating functional (a)symmetry within horses. GRF and kinematic data were collected from 10 horses trotting over a series of four force plates (120 Hz). The kinematic data were used to determine clean hoof contacts. The stance phase of each hoof was determined using a 50 N threshold. Vertical and longitudinal GRF for each stance phase were plotted both as force-time curves and as force vector diagrams in which vectors originating at the centre of pressure on the force plate were drawn at intervals of 8.3 ms for the duration of stance. Visual evaluation was facilitated by overlay of the vector diagrams for different limbs. Summary vectors representing the magnitude (VecMag) and direction (VecAng) of the mean force over the entire stance phase were superimposed on the force vector diagram. Typical measurements extracted from the force-time curves (peak forces, impulses) were compared with VecMag and VecAng using partial correlation (controlling for speed). Paired samples t -tests (left v. right diagonal pair comparison and high v. low vertical force diagonal pair comparison) were performed on discrete and vector variables using traditional methods and Hotelling's T 2 tests on normalized stance phase data using SPM. Evidence from traditional statistical tests suggested that VecMag is more influenced by the vertical force and impulse, whereas VecAng is more influenced by the

  13. Development of rapid and simple method for DNA extraction from cannabis resin based on the evaluation of relative PCR amplification ability.

    Science.gov (United States)

    Yamamuro, Tadashi; Iwata, Yuko T; Segawa, Hiroki; Kuwayama, Kenji; Tsujikawa, Kenji; Kanamori, Tatsuyuki; Inoue, Hiroyuki

    2018-04-04

    In recent years, analysis of cannabis DNA has been increasingly used in forensic drug tests. However, in the case of cannabis resin, a processed marijuana product, complicated procedures are required for the extraction of clean DNA, as the presence of various impurities inhibits PCR amplification. Therefore, in this study, we attempted to identify the factors that would allow quick and simple DNA extraction from cannabis resin with a commercially available kit. We also constructed a simple assay system for comparing relative amplification efficiencies by end-point PCR and used it to evaluate the purity of the obtained DNA solutions. For extraction with a kit that contains a silica column, reducing the starting amount of resin, using the residue remaining after methanol extraction, dilution of the final solution, extraction with an equal amount of powdered activated carbon or an excess amount of polyvinylpolypyrrolidone, and the addition of an appropriate amount of polyvinylpyrrolidone to the solution after extraction were effective measures that improved amplification efficiency. Furthermore, the use of the most rapid alkaline extraction kit combined with the addition of powdered activated carbon allowed obtaining DNA solutions with sufficient amplification efficiency in about 10min. These findings should be useful for routine DNA analysis of cannabis resin during forensic examination. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Simple and effective methods of freezing capercaillie (Tetrao urogallus L. semen.

    Directory of Open Access Journals (Sweden)

    Artur Kowalczyk

    Full Text Available A continuous decline in the number and range of capercaillie (Tetrao urogallus L. in many European countries can be observed, mostly due to habitat destruction by human activity, unecological forestry management, and increased density of natural predators. Ex situ in vitro gene banks provide a unique opportunity to preserve the genetic material for future generations. Simple and effective cryopreservation methods for capercaillie semen are discussed. Semen was collected from seven males kept in the Capercaillie Breeding Centre at Forestry Wisła in Poland. Within five minutes after collection, ejaculates were diluted with EK diluent, then divided into two parts, and subjected to two freezing procedures: in pellets and in straws. In fresh semen, ejaculate clearness, viscosity, color and volume, as well as sperm concentration, motility and morphology, were evaluated, while in frozen-thawed semen only motility and morphology of sperm were determined. Fertilizing ability of thawed semen was examined for samples frozen in straws. Significant (P<0.05 differences between individual males were found in relation to the majority of fresh semen traits: ejaculate volume averaged 102.1 µL (varying from 49.0 to 205.0; average sperm concentration was 632.5 x 10⁶ mL⁻¹ (178.8-1257.1; percentage of live normal cells varied from 39.2 to 70.3% (58.7% on an average; percentage of motile cells ranged from 76.0 to 85.7% and motility parameters were male dependent, as well. Both cryopreservation methods had a negative effect on morphology and motility of frozen-thawed semen; however, the straw method yielded 60.7% and the pellet method 42.5% of live cells in total in thawed semen (P<0.05, while the number of live normal (intact cells was similar (22.4 and 22.2%, respectively. Egg fertility varied between 77.8 and 91.7% (average 84.4%. Both freezing procedures seem to be effective in obtaining acceptable viability and high fertilizing potency of thawed sperm and

  15. Evaluation of Simple Treat 3.0 for two hydrophobic and slowly biodegradable chemicals: Polycyclic musks HHCB and AHTN

    NARCIS (Netherlands)

    Artola-Garicano, E.; Hermens, J.L.M.; Vaes, W.H.J.

    2003-01-01

    In the current study, predictions by Simple Treat 3.0, a fate model for organic chemicals in sewage treatment plants (STPs), are compared with actual measurements in three STPs. Two polycyclic musks, Tonalide® (AHTN) and Galaxolide® (HHCB), were used for model evaluation. Results show that Simple

  16. Mycobacterium avium restriction fragment lenght polymorphism-IS IS1245 and the simple double repetitive element polymerase chain reaction typing method to screen genetic diversity in Brazilian strains

    Directory of Open Access Journals (Sweden)

    Patrícia Carvalho de Sequeira

    2005-11-01

    Full Text Available Simple double repetitive element polymerase chain reaction (MaDRE-PCR and Pvu II-IS1245 restriction fragment length polymorphism (RFLP typing methods were used to type 41 Mycobacterium avium isolates obtained from 14 Aids inpatients and 10 environment and animals specimens identified among 53 mycobacteria isolated from 237 food, chicken, and pig. All environmental and animals strains showed orphan patterns by both methods. By MaDRE-PCR four patients, with multiple isolates, showed different patterns, suggesting polyclonal infection that was confirmed by RFLP in two of them. This first evaluation of MaDRE-PCR on Brazilian M. avium strains demonstrated that the method seems to be useful as simple and less expensive typing method for screening genetic diversity in M. avium strains on selected epidemiological studies, although with limitation on analysis identical patterns except for one band.

  17. A simple labeled test meal for the evaluation of gastric emptying

    International Nuclear Information System (INIS)

    Ishii, Keita; Tanabe, Satoshi; Mitsuhashi, Toshiharu; Saigenji, Katsunori

    1994-01-01

    We developed a simple test meal for the evaluation of gastric emptying. Preparation of a test meal for routine clinical use in institutions should be as simple as possible. The newly developed test meal consists of instant noodles labeled with 37 MBq (1 mCi) technetium-99m and does not require the use of cooking utensils. The test meal was given with drinking water (180 ml) to healthy adult volunteers (6 men, 34.5±2.2 years old) and gastric emptying was measured at 0, 5, 10, 15, 30, 45, 60, 80, 100, 120 minutes after the end of the meal, and results were compared with those derived without drinking water. The emptying pattern of the test meal with water exhibited an exponential pattern typical of a liquid meal, and that without water formed a linear pattern after an initial lag phase in keeping with gastric emptying of a solid meal. In addition, the test meal was given to 11 patients of diabetic gastroparesis (5 men, 6 women, 50.4±4.5 years old), and gastric emptying was measured. At each period evaluated, emptying was significantly slower in diabetic gastroparesis than in healthy controls (6 men, 1 woman, 32.1±3.0 years old). These results show that the test meal is reliable and applicable to the clinical assessment of gastric emptying, while fulfilling the need for simplicity. (author)

  18. Simple pulmonary eosinophilia evaluated by means of FDG PET: the findings of 14 cases

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Jung; Lee, Kyung Won [Seoul National University Bundang Hospital, Bundang (Korea, Republic of); Kim, Hyae Young; Lee, Joo Hyuk; Kim, Eun A; Kim, Seok Ki; Kang, Keon Wook [National Cancer Center, Seoul (Korea, Republic of)

    2005-12-15

    We wanted to describe the findings of simple pulmonary eosinophilia with using 18 fluorodeoxyglucose (FDG) positron emission tomography (PET). We analysed the findings of 14 patients who underwent thoracic computed tomography (CT) and PET, and then they were subsequently proven to have simple pulmonary eosinophilia. PET studies were performed in four patients with malignancy to evaluate for cancer metastasis, and PET scans were also done in 10 healthy subjects who underwent volunteer cancer screening. The PET scans were evaluated by using the maximum standardized uptake values (SUVs). The subjects' CT findings also were reviewed and correlated with the PET findings. A total of 42 nodules were detected on the CT scans. There were single nodules in three patients and multiple nodules in 11 patients (mean number of nodules: 3, range: 1-10, mean diameter: 9.5 mm {+-} 4.7). Twelve of 42 (28.6%) nodules showed FDG uptake and their mean maximum SUV was 2.5 {+-} 1.6 (range: 0.6-5.3). Five of six solid nodules showed FDG uptake (2.2 {+-} 1.1, range: 0.9-3.6), six of 11 semisolid nodules showed FDG uptake (3.1 {+-} 1.8, range: 0.6-5.3) and one of 25 pure ground-glass opacity nodule showed a maximum SUV of 0.8. The maximum SUVs of seven nodules in five patients were greater than 2.5. The maximum SUVs were significantly different according to the nodule types ({rho} < 0.001). Simple pulmonary eosinophilia commonly causes an increase in FDG uptake. Therefore, correlation of the PET findings with the CT findings or the peripheral eosinophil counts can help physicians arrive at the correct diagnosis of simple pulmonary eosinophilia.

  19. A new and simple gravimetric method for determination of uranium

    International Nuclear Information System (INIS)

    Saxena, A.K.

    1994-01-01

    A new and simple gravimetric method for determining uranium has been described. Using a known quantity of uranyl nitrate as the test solution, an alcoholic solution of 2-amino-2-methyl 1:3 propanediol (AMP) was added slowly. A yellow precipitate was obtained which was filtered through ashless filter paper, washed with alcohol, dried and ignited at 800 degC for 4h. It gave a black powder as a product which was shown by X-ray diffraction to be U 3 O 8 . The percentage error was found in the range -0.09 to +0.89. (author). 8 refs., 1 tab

  20. Simple analytical methods for computing the gravity-wave contribution to the cosmic background radiation anisotropy

    International Nuclear Information System (INIS)

    Wang, Y.

    1996-01-01

    We present two simple analytical methods for computing the gravity-wave contribution to the cosmic background radiation (CBR) anisotropy in inflationary models; one method uses a time-dependent transfer function, the other methods uses an approximate gravity-mode function which is a simple combination of the lowest order spherical Bessel functions. We compare the CBR anisotropy tensor multipole spectrum computed using our methods with the previous result of the highly accurate numerical method, the open-quote open-quote Boltzmann close-quote close-quote method. Our time-dependent transfer function is more accurate than the time-independent transfer function found by Turner, White, and Lindsey; however, we find that the transfer function method is only good for l approx-lt 120. Using our approximate gravity-wave mode function, we obtain much better accuracy; the tensor multipole spectrum we find differs by less than 2% for l approx-lt 50, less than 10% for l approx-lt 120, and less than 20% for l≤300 from the open-quote open-quote Boltzmann close-quote close-quote result. Our approximate graviton mode function should be quite useful in studying tensor perturbations from inflationary models. copyright 1996 The American Physical Society

  1. A Simple and Sensitive Plant-Based Western Corn Rootworm Bioassay Method for Resistance Determination and Event Selection.

    Science.gov (United States)

    Wen, Zhimou; Chen, Jeng Shong

    2018-05-26

    We report here a simple and sensitive plant-based western corn rootworm, Diabrotica virgifera virgifera LeConte (Coleoptera: Chrysomelidae), bioassay method that allows for examination of multiple parameters for both plants and insects in a single experimental setup within a short duration. For plants, injury to roots can be visually examined, fresh root weight can be measured, and expression of trait protein in plant roots can be analyzed. For insects, in addition to survival, larval growth and development can be evaluated in several aspects including body weight gain, body length, and head capsule width. We demonstrated using the method that eCry3.1Ab-expressing 5307 corn was very effective against western corn rootworm by eliciting high mortality and significantly inhibiting larval growth and development. We also validated that the method allowed determination of resistance in an eCry3.1Ab-resistant western corn rootworm strain. While data presented in this paper demonstrate the usefulness of the method for selection of events of protein traits and for determination of resistance in laboratory populations, we envision that the method can be applied in much broader applications.

  2. PROPOSED SIMPLE METHOD FOR ELECTROCARDIOGRAM RECORDING IN FREE-RANGING ASIAN ELEPHANTS (ELEPHAS MAXIMUS).

    Science.gov (United States)

    Chai, Norin; Pouchelon, Jean Louis; Bouvard, Jonathan; Sillero, Leonor Camacho; Huynh, Minh; Segalini, Vincent; Point, Lisa; Croce, Veronica; Rigaux, Goulven; Highwood, Jack; Chetboul, Valérie

    2016-03-01

    Electrocardiography represents a relevant diagnostic tool for detecting cardiac disease in animals. Elephants can present various congenital and acquired cardiovascular diseases. However, few electrophysiologic studies have been reported in captive elephants, mainly due to challenging technical difficulties in obtaining good-quality electrocardiogram (ECG) tracings, and no data are currently available for free-ranging Asian elephants (Elephas maximus). The purpose of this pilot prospective study was to evaluate the feasibility of using a simple method for recording ECG tracings in wild, apparently healthy, unsedated Asian elephants (n = 7) in the standing position. Successful six-lead recordings (I, II, III, aVR, aVL, and aVF) were obtained, with the aVL lead providing the best-quality tracings in most animals. Variables measured in the aVL lead included heart rate, amplitudes and duration of the P waves, QRS complexes, T and U waves, and duration of the PR, QT, and QU intervals. A negative deflection following positive P waves, representative of an atrial repolarization wave (Ta wave), was observed for five out of the seven elephants.

  3. A simple method to design non-collision relative orbits for close spacecraft formation flying

    Science.gov (United States)

    Jiang, Wei; Li, JunFeng; Jiang, FangHua; Bernelli-Zazzera, Franco

    2018-05-01

    A set of linearized relative motion equations of spacecraft flying on unperturbed elliptical orbits are specialized for particular cases, where the leader orbit is circular or equatorial. Based on these extended equations, we are able to analyze the relative motion regulation between a pair of spacecraft flying on arbitrary unperturbed orbits with the same semi-major axis in close formation. Given the initial orbital elements of the leader, this paper presents a simple way to design initial relative orbital elements of close spacecraft with the same semi-major axis, thus preventing collision under non-perturbed conditions. Considering the mean influence of J 2 perturbation, namely secular J 2 perturbation, we derive the mean derivatives of orbital element differences, and then expand them to first order. Thus the first order expansion of orbital element differences can be added to the relative motion equations for further analysis. For a pair of spacecraft that will never collide under non-perturbed situations, we present a simple method to determine whether a collision will occur when J 2 perturbation is considered. Examples are given to prove the validity of the extended relative motion equations and to illustrate how the methods presented can be used. The simple method for designing initial relative orbital elements proposed here could be helpful to the preliminary design of the relative orbital elements between spacecraft in a close formation, when collision avoidance is necessary.

  4. Simple and effective method for nuclear tellurium isomers separation from antimony cyclotron targets

    International Nuclear Information System (INIS)

    Bondarevskij, S.I.; Eremin, V.V.

    1999-01-01

    Simple and effective method of generation of tellurium nuclear isomers from irradiated on cyclotron metallic antimony is suggested. Basically this method consists in consideration of the big difference in volatilities of metallic forms of antimony, tin and tellurium. Heating of the tin-antimony alloy at 1200 K permits to separate about 90 % of produced quantity of 121m Te and 123m Te (in this case impurity of antimony radionuclides is not more than 1 % on activity) [ru

  5. A new method to study simple shear processing of wheat gluten-starch mixtures

    NARCIS (Netherlands)

    Peighambardoust, S.H.; Goot, A.J. van der; Hamer, R.J.; Boom, R.M.

    2004-01-01

    This article introduces a new method that uses a shearing device to study the effect of simple shear on the overall properties of pasta-like products made from commercial wheat gluten-starch (GS) blends. The shear-processed GS samples had a lower cooking loss (CL) and a higher swelling index (SI)

  6. A simple method for validation and verification of pipettes mounted on automated liquid handlers

    DEFF Research Database (Denmark)

    Stangegaard, Michael; Hansen, Anders Johannes; Frøslev, Tobias G

    2011-01-01

    We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared in quadru......We have implemented a simple, inexpensive, and fast procedure for validation and verification of the performance of pipettes mounted on automated liquid handlers (ALHs) as necessary for laboratories accredited under ISO 17025. A six- or seven-step serial dilution of OrangeG was prepared...... are freely available. In conclusion, we have set up a simple, inexpensive, and fast solution for the continuous validation of ALHs used for accredited work according to the ISO 17025 standard. The method is easy to use for aqueous solutions but requires a spectrophotometer that can read microtiter plates....

  7. Combinational Reasoning of Quantitative Fuzzy Topological Relations for Simple Fuzzy Regions

    Science.gov (United States)

    Liu, Bo; Li, Dajun; Xia, Yuanping; Ruan, Jian; Xu, Lili; Wu, Huanyi

    2015-01-01

    In recent years, formalization and reasoning of topological relations have become a hot topic as a means to generate knowledge about the relations between spatial objects at the conceptual and geometrical levels. These mechanisms have been widely used in spatial data query, spatial data mining, evaluation of equivalence and similarity in a spatial scene, as well as for consistency assessment of the topological relations of multi-resolution spatial databases. The concept of computational fuzzy topological space is applied to simple fuzzy regions to efficiently and more accurately solve fuzzy topological relations. Thus, extending the existing research and improving upon the previous work, this paper presents a new method to describe fuzzy topological relations between simple spatial regions in Geographic Information Sciences (GIS) and Artificial Intelligence (AI). Firstly, we propose a new definition for simple fuzzy line segments and simple fuzzy regions based on the computational fuzzy topology. And then, based on the new definitions, we also propose a new combinational reasoning method to compute the topological relations between simple fuzzy regions, moreover, this study has discovered that there are (1) 23 different topological relations between a simple crisp region and a simple fuzzy region; (2) 152 different topological relations between two simple fuzzy regions. In the end, we have discussed some examples to demonstrate the validity of the new method, through comparisons with existing fuzzy models, we showed that the proposed method can compute more than the existing models, as it is more expressive than the existing fuzzy models. PMID:25775452

  8. Development and validation of a simple method for the extraction of human skin melanocytes.

    Science.gov (United States)

    Wang, Yinjuan; Tissot, Marion; Rolin, Gwenaël; Muret, Patrice; Robin, Sophie; Berthon, Jean-Yves; He, Li; Humbert, Philippe; Viennet, Céline

    2018-03-21

    Primary melanocytes in culture are useful models for studying epidermal pigmentation and efficacy of melanogenic compounds, or developing advanced therapy medicinal products. Cell extraction is an inevitable and critical step in the establishment of cell cultures. Many enzymatic methods for extracting and growing cells derived from human skin, such as melanocytes, are described in literature. They are usually based on two enzymatic steps, Trypsin in combination with Dispase, in order to separate dermis from epidermis and subsequently to provide a suspension of epidermal cells. The objective of this work was to develop and validate an extraction method of human skin melanocytes being simple, effective and applicable to smaller skin samples, and avoiding animal reagents. TrypLE™ product was tested on very limited size of human skin, equivalent of multiple 3-mm punch biopsies, and was compared to Trypsin/Dispase enzymes. Functionality of extracted cells was evaluated by analysis of viability, morphology and melanin production. In comparison with Trypsin/Dispase incubation method, the main advantages of TrypLE™ incubation method were the easier of separation between dermis and epidermis and the higher population of melanocytes after extraction. Both protocols preserved morphological and biological characteristics of melanocytes. The minimum size of skin sample that allowed the extraction of functional cells was 6 × 3-mm punch biopsies (e.g., 42 mm 2 ) whatever the method used. In conclusion, this new procedure based on TrypLE™ incubation would be suitable for establishment of optimal primary melanocytes cultures for clinical applications and research.

  9. Determination of Some Cephalosporins in Pharmaceutical Formulations by a Simple and Sensitive Spectrofluorimetric Method

    Directory of Open Access Journals (Sweden)

    Ali Abdollahi, Ahad Bavili-Tabrizi

    2016-03-01

    Full Text Available Background: Cephalosporins are among the safest and the most effective broad-spectrum bactericidal antimicrobial agents which have been prescribed by the clinician as antibiotics. Thus, the developing of simple, sensitive and rapid analytical methods for their determination can be attractive and desirable. Methods: A simple, rapid and sensitive spectrofluorimetric method was developed for the determination of cefixime, cefalexin and ceftriaxone in pharmaceutical formulations. Proposed method is based on the oxidation of these cephalosporins with cerium (IV to produce cerium (III, and its fluorescence was monitored at 356 ± 3 nm after excitation at 254 ± 3 nm. Results: The variables effecting oxidation of each cephalosporin with cerum (IV were studied and optimized. Under the experimental conditions used, the calibration graphs were linear over the range 0.1-4 µg/mL. The limit of detection and limit of quantification were in the range 0.031-0.054 and 0.102-0.172 µg/mL, respectively. Intra- and inter-day assay precisions, expressed as the relative standard deviation (RSD, were lower than 5.6 and 6.8%, respectively. Conclusion: The proposed method was applied to the determination of studied cephalosporins in pharmaceutical formulations by good recoveries in the range 91-110%.

  10. A computational description of simple mediation analysis

    Directory of Open Access Journals (Sweden)

    Caron, Pier-Olivier

    2018-04-01

    Full Text Available Simple mediation analysis is an increasingly popular statistical analysis in psychology and in other social sciences. However, there is very few detailed account of the computations within the model. Articles are more often focusing on explaining mediation analysis conceptually rather than mathematically. Thus, the purpose of the current paper is to introduce the computational modelling within simple mediation analysis accompanied with examples with R. Firstly, mediation analysis will be described. Then, the method to simulate data in R (with standardized coefficients will be presented. Finally, the bootstrap method, the Sobel test and the Baron and Kenny test all used to evaluate mediation (i.e., indirect effect will be developed. The R code to implement the computation presented is offered as well as a script to carry a power analysis and a complete example.

  11. A simple method of shower localization and identification in laterally segmented calorimeters

    International Nuclear Information System (INIS)

    Awes, T.C.; Obenshain, F.E.; Plasil, F.; Saini, S.; Young, G.R.; Sorensen, S.P.

    1992-01-01

    A method is proposed to calculate the first and second moments of the spatial distribution of the energy of electromagnetic and hadronic showers measured in laterally segmented colorimeters. The technique uses a logarithmic weighting of energy fraction observed in the individual detector cells. It is fast and simple requiring no fitting or complicated corrections for the position or angle of incidence. The method is demonstrated with GEANT simulations of a BGO detector array. The position resolution results and the e/π separation results are found to be equal or superior to those obtained with more complicated techniques. (orig.)

  12. An improved broadband method to evaluate effective parameters of slab metamaterials in the microwave frequency range

    International Nuclear Information System (INIS)

    Rybin, O.; Nawaz, T.; Abbasi, T.

    2007-01-01

    An improved broadband method for determining complex effective refractive index, permittivity and permeability of an arbitrary passive metamaterial in microwave frequency range has been proposed. Evaluation of the effective parameters is realized using the reflection-transmission S-parameters obtained by simulation or experimental measurements and analytically evaluated interface reflection coefficient of the slab. Formulas for evaluation of effective permittivity and permeability which contain the square root of complex functions of S-parameters have been proposed in (1-2). But this method does not propose a way to avoid an ambiguity arising in choosing the square root branch of product of effective permittivity and permeability. Moreover the above calculation procedure requires evaluating the square root branch of function of S-parameters. Proposed way to choose the square root branch gives sometimes mistaken results. Our method is much simple as compared with the above mentioned formulas and it does not require making a choice of square root branch of complex functions of S-parameters in order to evaluate any of the parameters (refractive index, permittivity or permeability). Instead we obtain a formula for complex refractive index which is simple. On the basis of proposed model effective permittivity and permeability for rod meta-materials can be evaluated with enhanced precision and accuracy. Proposed method is easy to be implemented in engineering problems and does not require using complicated mathematical calculations. Comparison of precision of the presented method with the Nicolson-Ross techniques (1-2) has been made using the simulations for different configurations of rod meta-materials. Some discussion concerning the sensitivity of the effective parameters of meta-materials for the accuracy of the frequency dependent S -parameters is also presented in this paper. (author)

  13. A simple method for deriving functional MSCs and applied for osteogenesis in 3D scaffolds

    DEFF Research Database (Denmark)

    Zou, Lijin; Luo, Yonglun; Chen, Muwan

    2013-01-01

    We describe a simple method for bone engineering using biodegradable scaffolds with mesenchymal stem cells derived from human induced-pluripotent stem cells (hiPS-MSCs). The hiPS-MSCs expressed mesenchymal markers (CD90, CD73, and CD105), possessed multipotency characterized by tri......-lineages differentiation: osteogenic, adipogenic, and chondrogenic, and lost pluripotency - as seen with the loss of markers OCT3/4 and TRA-1-81 - and tumorigenicity. However, these iPS-MSCs are still positive for marker NANOG. We further explored the osteogenic potential of the hiPS-MSCs in synthetic polymer......, our results suggest the iPS-MSCs derived by this simple method retain fully osteogenic function and provide a new solution towards personalized orthopedic therapy in the future....

  14. A simple method for identification of irradiated spices

    International Nuclear Information System (INIS)

    Behere, A.; Desai, S.R.P.; Nair, P.M.; Rao, S.M.D.

    1992-01-01

    Thermoluminescence (TL) properties of curry powder, a salt containing spice mixture, and three different ground spices, viz, chilli, turmeric and pepper, were compared with TL of table salt. The spices other than curry powder, did not exhibit characteristic TL in the absence of salt. Therefore studies were initiated to develop a simple and reliable method using common salt for distinguishing irradiated spices (10 kGy) from unirradiated ones under normal conditions of storage. Common salt exhibited a characteristic TL glow at 170 o C. However, when present in curry powder, the TL glow of salt showed a shift to 208 o C. It was further observed that upon storage up to 6 months, the TL of irradiated curry powder retained about 10% of the original intensity and still could be distinguished from the untreated samples. From our results it is evident that common salt could be used as an indicator either internally or externally in small sachets for incorporating into prepacked spices. (author)

  15. A simple method for identification of irradiated spices

    Energy Technology Data Exchange (ETDEWEB)

    Behere, A; Desai, S R.P.; Nair, P M [Bhabha Atomic Research Centre, Bombay (India). Food Technology and Enzyme Engineering Div.; Rao, S M.D. [Bhabha Atomic Research Centre, Bombay (India). Technical Physics and Prototype Engineering Div.

    1992-07-01

    Thermoluminescence (TL) properties of curry powder, a salt containing spice mixture, and three different ground spices, viz, chilli, turmeric and pepper, were compared with TL of table salt. The spices other than curry powder, did not exhibit characteristic TL in the absence of salt. Therefore studies were initiated to develop a simple and reliable method using common salt for distinguishing irradiated spices (10 kGy) from unirradiated ones under normal conditions of storage. Common salt exhibited a characteristic TL glow at 170{sup o}C. However, when present in curry powder, the TL glow of salt showed a shift to 208{sup o}C. It was further observed that upon storage up to 6 months, the TL of irradiated curry powder retained about 10% of the original intensity and still could be distinguished from the untreated samples. From our results it is evident that common salt could be used as an indicator either internally or externally in small sachets for incorporating into prepacked spices. (author).

  16. Simple method of measuring pulmonary extravascular water using heavy water

    Energy Technology Data Exchange (ETDEWEB)

    Basset, G; Moreau, F; Scaringella, M; Tistchenko, S; Botter, F; Marsac, J

    1975-11-20

    The field of application of the multiple indicators dilution method in human pathology, already used to study pulmonary edema, can be extended to cover the identification and testing of all conditions leading to increase lung water. To be really practical it must be simple, fast, sensitive, inexpensive and subject to repetition; the use of non-radioactive tracers is implied. Indocyanine Green and heavy water were chosen respectively as vascular and diffusible indicators. Original methods have been developed for the treatment and isotopic analysis of blood: mass spectrometric analysis of aqueous blood extracts after deproteinisation by zinc sulphate then rapid distillation of the supernatant under helium; infrared analysis either of acetone extracts from small blood samples (100..mu..litre) or of blood itself in a continuous measurement. The infrared technique adopted has been used on rats and on men in normal and pathological situations. The results show that the method proposed for the determination of pulmonary extravascular water meets the requirements of clinicians while respecting the patients' safety, and could be generalized to other organs.

  17. A simple source preparation method for alpha-ray spectrometry of volcanic rock sample

    International Nuclear Information System (INIS)

    Takahashi, Masaomi; Kurihara, Yuichi; Sato, Jun

    2006-01-01

    A simple source preparation method was developed for the alpha-ray spectrometry to determine U and Th in volcanic rockes. Isolation of U and Th from volcanic rocks was made by use of UTEVA-Spec. resin, extraction chromatograph material. U and Th were extracted by TTA-benzene solution and organic phase was evaporated drop by drop on a hot stainless steel planchet to dryness. This method was found to be effective for the preparation of sources for alpha-ray spectrometry. (author)

  18. An evaluation method for tornado missile strike probability with stochastic correction

    Energy Technology Data Exchange (ETDEWEB)

    Eguchi, Yuzuru; Murakami, Takahiro; Hirakuchi, Hiromaru; Sugimoto, Soichiro; Hattori, Yasuo [Nuclear Risk Research Center (External Natural Event Research Team), Central Research Institute of Electric Power Industry, Abiko (Japan)

    2017-03-15

    An efficient evaluation method for the probability of a tornado missile strike without using the Monte Carlo method is proposed in this paper. A major part of the proposed probability evaluation is based on numerical results computed using an in-house code, Tornado-borne missile analysis code, which enables us to evaluate the liftoff and flight behaviors of unconstrained objects on the ground driven by a tornado. Using the Tornado-borne missile analysis code, we can obtain a stochastic correlation between local wind speed and flight distance of each object, and this stochastic correlation is used to evaluate the conditional strike probability, QV(r), of a missile located at position r, where the local wind speed is V. In contrast, the annual exceedance probability of local wind speed, which can be computed using a tornado hazard analysis code, is used to derive the probability density function, p(V). Then, we finally obtain the annual probability of tornado missile strike on a structure with the convolutional integration of product of QV(r) and p(V) over V. The evaluation method is applied to a simple problem to qualitatively confirm the validity, and to quantitatively verify the results for two extreme cases in which an object is located just in the vicinity of or far away from the structure.

  19. An evaluation method for tornado missile strike probability with stochastic correction

    International Nuclear Information System (INIS)

    Eguchi, Yuzuru; Murakami, Takahiro; Hirakuchi, Hiromaru; Sugimoto, Soichiro; Hattori, Yasuo

    2017-01-01

    An efficient evaluation method for the probability of a tornado missile strike without using the Monte Carlo method is proposed in this paper. A major part of the proposed probability evaluation is based on numerical results computed using an in-house code, Tornado-borne missile analysis code, which enables us to evaluate the liftoff and flight behaviors of unconstrained objects on the ground driven by a tornado. Using the Tornado-borne missile analysis code, we can obtain a stochastic correlation between local wind speed and flight distance of each object, and this stochastic correlation is used to evaluate the conditional strike probability, QV(r), of a missile located at position r, where the local wind speed is V. In contrast, the annual exceedance probability of local wind speed, which can be computed using a tornado hazard analysis code, is used to derive the probability density function, p(V). Then, we finally obtain the annual probability of tornado missile strike on a structure with the convolutional integration of product of QV(r) and p(V) over V. The evaluation method is applied to a simple problem to qualitatively confirm the validity, and to quantitatively verify the results for two extreme cases in which an object is located just in the vicinity of or far away from the structure

  20. A Simple and Clean Method for O-Isopropylidenation of Carbohydrates

    Energy Technology Data Exchange (ETDEWEB)

    Rong, Yuan Wei; Zhang, Qi Hua; Wang, Wei; Li, Bao Lin [Shaanxi Normal Univ., Xi' an (China)

    2014-07-15

    An efficient catalysis system for the synthesis of O-isopropylidene derivatives of sugars and polyhydroxy alcohols has been developed with sulfonated polystyrene cation exchange resin CAT600 as a catalyst. The key advantages of this protocol are simple workup, good yields and the recoverability, the innocuity and low cost of the catalyst. As a green, general and efficient reaction system, this method is expected to attract much attention for the preparation of various O-isopropylidene sugar derivatives in a large scale. Protection of hydroxyl functions by O-isopropylidenation is an important method in the field of carbohydrate chemistry. Due to its convenient application in synthetic, configurational and conformational studies, the O-isopropylidene derivatives of sugars play an important role in the research of building blocks, such as glycosyl acceptors and glycosyl donors. Additionally, these derivatives of sugars are important in the synthesis of various natural products.

  1. Short report: evaluation of a simple and inexpensive photometric device for the measurement of hemoglobin

    NARCIS (Netherlands)

    Borrmann, Steffen; Oyakhirome, Sunny; Esser, Gilbert; Trinkle, Cordula; Issifou, Saadou; Grobusch, Martin P.; Krishna, Sanjeev; Kremsner, Peter G.

    2004-01-01

    We have evaluated the accuracy of a simple and inexpensive photometric device (DHT) for the estimation of the blood concentration of hemoglobin by comparison with an automated, high-resolution, flow cytometry-based hematology analyzer (CellDyn 3000) and a centrifugal quantitative buffy coat

  2. A simple graphical method for measuring inherent safety

    International Nuclear Information System (INIS)

    Gupta, J.P.; Edwards, David W.

    2003-01-01

    Inherently safer design (ISD) concepts have been with us for over two decades since their elaboration by Kletz [Chem. Ind. 9 (1978) 124]. Interest has really taken off globally since the early nineties after several major mishaps occurred during the eighties (Bhopal, Mexico city, Piper-alfa, Philips Petroleum, to name a few). Academic and industrial research personnel have been actively involved into devising inherently safer ways of production. The regulatory bodies have also shown deep interest since ISD makes the production safer and hence their tasks easier. Research funding has also been forthcoming for new developments as well as for demonstration projects. A natural question that arises is as to how to measure ISD characteristics of a process? Several researchers have worked on this [Trans. IChemE, Process Safety Environ. Protect. B 71 (4) (1993) 252; Inherent safety in process plant design, Ph.D. Thesis, VTT Publication Number 384, Helsinki University of Technology, Espoo, Finland, 1999; Proceedings of the Mary Kay O'Connor Process Safety Center Symposium, 2001, p. 509]. Many of the proposed methods are very elegant, yet too involved for easy adoption by the industry which is scared of yet another safety analysis regime. In a recent survey [Trans. IChemE, Process Safety Environ. Prog. B 80 (2002) 115], companies desired a rather simple method to measure ISD. Simplification is also an important characteristic of ISD. It is therefore desirable to have a simple ISD measurement procedure. The ISD measurement procedure proposed in this paper can be used to differentiate between two or more processes for the same end product. The salient steps are: Consider each of the important parameters affecting the safety (e.g., temperature, pressure, toxicity, flammability, etc.) and the range of possible values these parameters can have for all the process routes under consideration for an end product. Plot these values for each step in each process route and compare. No

  3. The Effect of Herrmann Whole Brain Teaching Method on Students' Understanding of Simple Electric Circuits

    Science.gov (United States)

    Bawaneh, Ali Khalid Ali; Nurulazam Md Zain, Ahmad; Salmiza, Saleh

    2011-01-01

    The purpose of this study was to investigate the effect of Herrmann Whole Brain Teaching Method over conventional teaching method on eight graders in their understanding of simple electric circuits in Jordan. Participants (N = 273 students; M = 139, F = 134) were randomly selected from Bani Kenanah region-North of Jordan and randomly assigned to…

  4. A Simple Method for Assessing Severity of Common Root Rot on Barley

    Directory of Open Access Journals (Sweden)

    Mohammad Imad Eddin Arabi

    2013-12-01

    Full Text Available Common root rot caused by Cochliobolus sativus is a serious disease of barley. A simple and reliable method for assessing this disease would enhance our capacity in identifying resistance sources and developing resistant barley cultivars. In searching for such a method, a conidial suspension of C. sativus was dropped onto sterilized elongated subcrown internodes and incubated in sandwich filter paper using polyethylene transparent envelopes. Initial disease symptoms were easily detected after 48h of inoculation. Highly significant correlation coefficients were found in each experiment (A, B and C between sandwich filter paper and seedling assays, indicating that this testing procedure was reliable. The method presented facilitates a rapid pre-selection under uniform conditions which is of importance from a breeder’s point of view.

  5. Fabricating superhydrophobic polymer surfaces with excellent abrasion resistance by a simple lamination templating method.

    Science.gov (United States)

    Xu, Qian Feng; Mondal, Bikash; Lyons, Alan M

    2011-09-01

    Fabricating robust superhydrophobic surfaces for commercial applications is challenging as the fine-scale surface features, necessary to achieve superhydrophobicity, are susceptible to mechanical damage. Herein, we report a simple and inexpensive lamination templating method to create superhydrophobic polymer surfaces with excellent abrasion resistance and water pressure stability. To fabricate the surfaces, polyethylene films were laminated against woven wire mesh templates. After cooling, the mesh was peeled from the polymer creating a 3D array of ordered polymer microposts on the polymer surface. The resulting texture is monolithic with the polymer film and requires no chemical modification to exhibit superhydrophobicity. By controlling lamination parameters and mesh dimensions, polyethylene surfaces were fabricated that exhibit static contact angles of 160° and slip angles of 5°. Chemical and mechanical stability was evaluated using an array of manual tests as well as a standard reciprocating abraser test. Surfaces remained superhydrophobic after more than 5500 abrasion cycles at a pressure of 32.0 kPa. In addition, the surface remains dry after immersing into water for 5 h at 55 kPa. This method is environmental friendly, as it employs no solvents or harsh chemicals and may provide an economically viable path to manufacture large areas of mechanically robust superhydrophobic surfaces from inexpensive polymers and reusable templates.

  6. Multiclass mycotoxin analysis in edible oils using a simple solvent extraction method and liquid chromatography with tandem mass spectrometry.

    Science.gov (United States)

    Eom, Taeyong; Cho, Hyun-Deok; Kim, Junghyun; Park, Mihee; An, Jinyoung; Kim, Moosung; Kim, Sheen-Hee; Han, Sang Beom

    2017-11-01

    A simple and rapid method for the simultaneous determination of 11 mycotoxins - aflatoxins B 1 , B 2 , G 1 and G 2 ; fumonisins B 1 , B 2 and B 3 ; ochratoxin A; zearalenone; deoxynivalenol; and T-2 toxin - in edible oils was established using liquid chromatography tandem mass spectrometry (LC-MS/MS). In this study, QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe), QuEChERS with dispersive liquid-liquid microextraction, and solvent extraction were examined for sample preparation. Among these methods, solvent extraction with a mixture of formic acid/acetonitrile (5/95, v/v) successfully extracted all target mycotoxins. Subsequently, a defatting process using n-hexane was employed to remove the fats present in the edible oil samples. Mass spectrometry was carried out using electrospray ionisation in polarity switching mode with multiple reaction monitoring. The developed LC-MS/MS method was validated by assessing the specificity, linearity, recovery, limit of quantification (LOQ), accuracy and precision with reference to Commission Regulation (EC) 401/2006. Mycotoxin recoveries of 51.6-82.8% were achieved in addition to LOQs ranging from 0.025 ng/g to 1 ng/g. The edible oils proved to be relatively uncomplicated matrices and the developed method was applied to 9 edible oil samples, including soybean oil, corn oil and rice bran oil, to evaluate potential mycotoxin contamination. The levels of detection were significantly lower than the international regulatory standards. Therefore, we expect that our developed method, based on simple, two-step sample preparation process, will be suitable for the large-scale screening of mycotoxin contamination in edible oils.

  7. A simple and efficient total genomic DNA extraction method for individual zooplankton.

    Science.gov (United States)

    Fazhan, Hanafiah; Waiho, Khor; Shahreza, Md Sheriff

    2016-01-01

    Molecular approaches are widely applied in species identification and taxonomic studies of minute zooplankton. One of the most focused zooplankton nowadays is from Subclass Copepoda. Accurate species identification of all life stages of the generally small sized copepods through molecular analysis is important, especially in taxonomic and systematic assessment of harpacticoid copepod populations and to understand their dynamics within the marine community. However, total genomic DNA (TGDNA) extraction from individual harpacticoid copepods can be problematic due to their small size and epibenthic behavior. In this research, six TGDNA extraction methods done on individual harpacticoid copepods were compared. The first new simple, feasible, efficient and consistent TGDNA extraction method was designed and compared with the commercial kit and modified available TGDNA extraction methods. The newly described TGDNA extraction method, "Incubation in PCR buffer" method, yielded good and consistent results based on the high success rate of PCR amplification (82%) compared to other methods. Coupled with its relatively consistent and economical method the "Incubation in PCR buffer" method is highly recommended in the TGDNA extraction of other minute zooplankton species.

  8. Sonographic Diagnosis of Tubal Cancer with IOTA Simple Rules Plus Pattern Recognition

    Science.gov (United States)

    Tongsong, Theera; Wanapirak, Chanane; Tantipalakorn, Charuwan; Tinnangwattana, Dangcheewan

    2017-11-26

    Objective: To evaluate diagnostic performance of IOTA simple rules plus pattern recognition in predicting tubal cancer. Methods: Secondary analysis was performed on prospective database of our IOTA project. The patients recruited in the project were those who were scheduled for pelvic surgery due to adnexal masses. The patients underwent ultrasound examinations within 24 hours before surgery. On ultrasound examination, the masses were evaluated using the well-established IOTA simple rules plus pattern recognition (sausage-shaped appearance, incomplete septum, visible ipsilateral ovaries) to predict tubal cancer. The gold standard diagnosis was based on histological findings or operative findings. Results: A total of 482 patients, including 15 cases of tubal cancer, were evaluated by ultrasound preoperatively. The IOTA simple rules plus pattern recognition gave a sensitivity of 86.7% (13 in 15) and specificity of 97.4%. Sausage-shaped appearance was identified in nearly all cases (14 in 15). Incomplete septa and normal ovaries could be identified in 33.3% and 40%, respectively. Conclusion: IOTA simple rules plus pattern recognition is relatively effective in predicting tubal cancer. Thus, we propose the simple scheme in diagnosis of tubal cancer as follows. First of all, the adnexal masses are evaluated with IOTA simple rules. If the B-rules could be applied, tubal cancer is reliably excluded. If the M-rules could be applied or the result is inconclusive, careful delineation of the mass with pattern recognition should be performed. Creative Commons Attribution License

  9. A simple method for the deconvolution of 134 Cs/137 Cs peaks in gamma-ray scintillation spectrometry

    International Nuclear Information System (INIS)

    Darko, E.O.; Osae, E.K.; Schandorf, C.

    1998-01-01

    A simple method for the deconvolution of 134 Cs / 137 Cs peaks in a given mixture of 134 Cs and 137 Cs using Nal(TI) gamma-ray scintillation spectrometry is described. In this method the 795 keV energy of 134 Cs is used as a reference peak to calculate the activity of the 137 Cs directly from the measured peaks. Certified reference materials were measured using the method and compared with a high resolution gamma-ray spectrometry measurements. The results showed good agreement with the certified values. The method is very simple and does not need any complicated mathematics and computer programme to de- convolute the overlapping 604.7 keV and 661.6 keV peaks of 134 Cs and 137 Cs respectively. (author). 14 refs.; 1 tab., 2 figs

  10. A simple and robust statistical framework for planning, analysing and interpreting faecal egg count reduction test (FECRT) studies

    DEFF Research Database (Denmark)

    Denwood, M.J.; McKendrick, I.J.; Matthews, L.

    Introduction. There is an urgent need for a method of analysing FECRT data that is computationally simple and statistically robust. A method for evaluating the statistical power of a proposed FECRT study would also greatly enhance the current guidelines. Methods. A novel statistical framework has...... been developed that evaluates observed FECRT data against two null hypotheses: (1) the observed efficacy is consistent with the expected efficacy, and (2) the observed efficacy is inferior to the expected efficacy. The method requires only four simple summary statistics of the observed data. Power...... that the notional type 1 error rate of the new statistical test is accurate. Power calculations demonstrate a power of only 65% with a sample size of 20 treatment and control animals, which increases to 69% with 40 control animals or 79% with 40 treatment animals. Discussion. The method proposed is simple...

  11. Title: a simple method to evaluate linac beam homogeneity

    International Nuclear Information System (INIS)

    Monti, A.F.; Ostinelli, A.; Gelosa, S.; Frigerio, M.

    1995-01-01

    Quality Control (QC) tests in Radiotherapy represent a basic requirement to asses treatment units performance and treatment quality. Since they are generally time consuming, it is worth while to introduce procedures and methods which can be carried on more easily and quickly. Since 1994 in the Radiotherapy Department of S. Anna Hospital, it had been employed a commercially available solid phantom (PRECITRON) with a 10 diodes array, to investigate beam homogeneity (symmetry and flatness). In particular, global symmetry percentage indexes were defined which consider pairs of corresponding points along each axis (x and y) and compare the readings of the respective diodes, following the formula: (I gs =((X d + X -d ) - (Y d + Y -d )((X d + X -d ) + (Y d + Y -d )*200 where X d and X -d are points 8 or 10 cm equally spaced from the beam centre along x axis and the same for Y d and Y -d along y axis. Even if non supporting international protocols requirements as a whole, this parameter gives an important information about beam homogeneity, when only few points of measure are available in a plane, and it can be daily determined, thus fulfilling the aim of lightning immediately each situation capable to compromise treatment accuracy and effectiveness. In this poster we report the results concerning this parameter for a linear accelerator (Varian Clinac 1800), since September 1994 to September 1995

  12. Simple method for generating adjustable trains of picosecond electron bunches

    Directory of Open Access Journals (Sweden)

    P. Muggli

    2010-05-01

    Full Text Available A simple, passive method for producing an adjustable train of picosecond electron bunches is demonstrated. The key component of this method is an electron beam mask consisting of an array of parallel wires that selectively spoils the beam emittance. This mask is positioned in a high magnetic dispersion, low beta-function region of the beam line. The incoming electron beam striking the mask has a time/energy correlation that corresponds to a time/position correlation at the mask location. The mask pattern is transformed into a time pattern or train of bunches when the dispersion is brought back to zero downstream of the mask. Results are presented of a proof-of-principle experiment demonstrating this novel technique that was performed at the Brookhaven National Laboratory Accelerator Test Facility. This technique allows for easy tailoring of the bunch train for a particular application, including varying the bunch width and spacing, and enabling the generation of a trailing witness bunch.

  13. A simple and accurate onset detection method for a measured bell-shaped speed profile

    Directory of Open Access Journals (Sweden)

    Lior Botzer

    2009-06-01

    Full Text Available Motor control neuroscientists measure limb trajectories and extract the onset of the movement for a variety of purposes. Such trajectories are often aligned relative to the onset of individual movement before the features of that movement are extracted and their properties are inspected. Onset detection is performed either manually or automatically, typically by selecting a velocity threshold. Here, we present a simple onset detection algorithm that is more accurate than the conventional velocity threshold technique. The proposed method is based on a simple regression and follows the minimum acceleration with constraints model, in which the initial phase of the bell-shaped movement is modeled by a cubic power of the time. We demonstrate the performance of the suggested method and compare it to the velocity threshold technique and to manual onset detection by a group of motor control experts. The database for this comparison consists of simulated minimum jerk trajectories and recorded reaching movements.

  14. A simple method for detecting tumor in T2-weighted MRI brain images. An image-based analysis

    International Nuclear Information System (INIS)

    Lau, Phooi-Yee; Ozawa, Shinji

    2006-01-01

    The objective of this paper is to present a decision support system which uses a computer-based procedure to detect tumor blocks or lesions in digitized medical images. The authors developed a simple method with a low computation effort to detect tumors on T2-weighted Magnetic Resonance Imaging (MRI) brain images, focusing on the connection between the spatial pixel value and tumor properties from four different perspectives: cases having minuscule differences between two images using a fixed block-based method, tumor shape and size using the edge and binary images, tumor properties based on texture values using spatial pixel intensity distribution controlled by a global discriminate value, and the occurrence of content-specific tumor pixel for threshold images. Measurements of the following medical datasets were performed: different time interval images, and different brain disease images on single and multiple slice images. Experimental results have revealed that our proposed technique incurred an overall error smaller than those in other proposed methods. In particular, the proposed method allowed decrements of false alarm and missed alarm errors, which demonstrate the effectiveness of our proposed technique. In this paper, we also present a prototype system, known as PCB, to evaluate the performance of the proposed methods by actual experiments, comparing the detection accuracy and system performance. (author)

  15. Development of a simple estimation tool for LMFBR construction cost

    International Nuclear Information System (INIS)

    Yoshida, Kazuo; Kinoshita, Izumi

    1999-01-01

    A simple tool for estimating the construction costs of liquid-metal-cooled fast breeder reactors (LMFBRs), 'Simple Cost' was developed in this study. Simple Cost is based on a new estimation formula that can reduce the amount of design data required to estimate construction costs. Consequently, Simple cost can be used to estimate the construction costs of innovative LMFBR concepts for which detailed design has not been carried out. The results of test calculation show that Simple Cost provides cost estimations equivalent to those obtained with conventional methods within the range of plant power from 325 to 1500 MWe. Sensitivity analyses for typical design parameters were conducted using Simple Cost. The effects of four major parameters - reactor vessel diameter, core outlet temperature, sodium handling area and number of secondary loops - on the construction costs of LMFBRs were evaluated quantitatively. The results show that the reduction of sodium handling area is particularly effective in reducing construction costs. (author)

  16. Alternative prediction methods of protein and energy evaluation of pig feeds.

    Science.gov (United States)

    Święch, Ewa

    2017-01-01

    Precise knowledge of the actual nutritional value of individual feedstuffs and complete diets for pigs is important for efficient livestock production. Methods of assessment of protein and energy values in pig feeds have been briefly described. In vivo determination of protein and energy values of feeds in pigs are time-consuming, expensive and very often require the use of surgically-modified animals. There is a need for more simple, rapid, inexpensive and reproducible methods for routine feed evaluation. Protein and energy values of pig feeds can be estimated using the following alternative methods: 1) prediction equations based on chemical composition; 2) animal models as rats, cockerels and growing pigs for adult animals; 3) rapid methods, such as the mobile nylon bag technique and in vitro methods. Alternative methods developed for predicting the total tract and ileal digestibility of nutrients including amino acids in feedstuffs and diets for pigs have been reviewed. This article focuses on two in vitro methods that can be used for the routine evaluation of amino acid ileal digestibility and energy value of pig feeds and on factors affecting digestibility determined in vivo in pigs and by alternative methods. Validation of alternative methods has been carried out by comparing the results obtained using these methods with those acquired in vivo in pigs. In conclusion, energy and protein values of pig feeds may be estimated with satisfactory precision in rats and by the two- or three-step in vitro methods providing equations for the calculation of standardized ileal digestibility of amino acids and metabolizable energy content. The use of alternative methods of feed evaluation is an important way for reduction of stressful animal experiments.

  17. A simple MC-based algorithm for evaluating reliability of stochastic-flow network with unreliable nodes

    International Nuclear Information System (INIS)

    Yeh, W.-C.

    2004-01-01

    A MP/minimal cutset (MC) is a path/cut set such that if any edge is removed from this path/cut set, then the remaining set is no longer a path/cut set. An intuitive method is proposed to evaluate the reliability in terms of MCs in a stochastic-flow network subject to both edge and node failures under the condition that all of the MCs are given in advance. This is an extension of the best of known algorithms for solving the d-MC (a special MC but formatted in a system-state vector, where d is the lower bound points of the system capacity level) problem from the stochastic-flow network without unreliable nodes to with unreliable nodes by introducing some simple concepts. These concepts were first developed in the literature to implement the proposed algorithm to reduce the number of d-MC candidates. This method is more efficient than the best of known existing algorithms regardless if the network has or does not have unreliable nodes. Two examples are illustrated to show how the reliability is determined using the proposed algorithm in the network with or without unreliable nodes. The computational complexity of the proposed algorithm is analyzed and compared with the existing methods

  18. A Simple Method for High-Lift Propeller Conceptual Design

    Science.gov (United States)

    Patterson, Michael; Borer, Nick; German, Brian

    2016-01-01

    In this paper, we present a simple method for designing propellers that are placed upstream of the leading edge of a wing in order to augment lift. Because the primary purpose of these "high-lift propellers" is to increase lift rather than produce thrust, these props are best viewed as a form of high-lift device; consequently, they should be designed differently than traditional propellers. We present a theory that describes how these props can be designed to provide a relatively uniform axial velocity increase, which is hypothesized to be advantageous for lift augmentation based on a literature survey. Computational modeling indicates that such propellers can generate the same average induced axial velocity while consuming less power and producing less thrust than conventional propeller designs. For an example problem based on specifications for NASA's Scalable Convergent Electric Propulsion Technology and Operations Research (SCEPTOR) flight demonstrator, a propeller designed with the new method requires approximately 15% less power and produces approximately 11% less thrust than one designed for minimum induced loss. Higher-order modeling and/or wind tunnel testing are needed to verify the predicted performance.

  19. Colour evaluation in scars: tristimulus colorimeter, narrow-band simple reflectance meter or subjective evaluation?

    Science.gov (United States)

    Draaijers, Lieneke J; Tempelman, Fenike R H; Botman, Yvonne A M; Kreis, Robert W; Middelkoop, Esther; van Zuijlen, Paul P M

    2004-03-01

    The evaluation of scar colour is, at present, usually limited to an assessment according to a scar assessment scale. Although useful, these assessment scales only evaluate subjectively the degree of scar colour. In this study, the reliability of the subjective assessment of scar colour by observers is compared to the reliability of the measurements of two objective colour measurement instruments. Four independent observers subjectively assessed the vascularisation and pigmentation of 49 scar areas in 20 patients. The degree of vascularisation and pigmentation was scored according to a scale ranging from '1', when it appeared to be like healthy skin, to '10', which corresponds to the worst imaginable outcome of vascularisation or pigmentation. The observers also scored the pigmentation categories of the scar (hypopigmention, hyperpigmention or mixed pigmentation). Finally, each observer measured the scar areas with a tristimulus colorimeter (Minolta Chromameter) and a narrow-band simple reflectance meter (DermaSpectrometer). A single observer could reliably carry out measurements of the DermaSpectrometer and the Minolta Chromameter for the evaluation of scar colour (r = 0.72). The vascularisation of scars could also be assessed reliably with a single observer (r = 0.76) whereas for a reliable assessment of pigmentation at least three observers were necessary (r > or = 0.77). The agreement between the observers for the pigmentation categories also turned out to be unacceptably low (k = 0.349). This study shows that an overall evaluation of scar colour with the DermaSpectrometer and the Minolta Chromameter is more reliable than the evaluation of scar colour with observers. Of both instruments for measuring scar colour, we prefer, because of its feasibility, the DermaSpectrometer.

  20. Structure of simple liquids; Structure des liquides simples

    Energy Technology Data Exchange (ETDEWEB)

    Blain, J F [Commissariat a l' Energie Atomique, Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1969-07-01

    The results obtained by application to argon and sodium of the two important methods of studying the structure of liquids: scattering of X-rays and neutrons, are presented on one hand. On the other hand the principal models employed for reconstituting the structure of simple liquids are exposed: mathematical models, lattice models and their derived models, experimental models. (author) [French] On presente d'une part les resultats obtenus par application a l'argon et au sodium des deux principales methodes d'etude de la structure des liquides: la diffusion des rayons X et la diffusion des neutrons; d'autre part, les principaux modeles employes pour reconstituer la structure des liquides simples sont exposes: modeles mathematiques, modeles des reseaux et modeles derives, modeles experimentaux. (auteur)

  1. Evaluation of Simple and Inexpensive High-Throughput Methods for Phytic Acid Determination

    DEFF Research Database (Denmark)

    Raboy, Victor; Johnson, Amy; Bilyeu, Kristin

    2017-01-01

    High-throughput/low-cost/low-tech methods for phytic acid determination that are sufficiently accurate and reproducible would be of value in plant genetics, crop breeding and in the food and feed industries. Variants of two candidate methods, those described by Vaintraub and Lapteva (Anal Biochem...... and legume flours regardless of endogenous phytic acid levels or matrix constituents....

  2. Nuclear data evaluation method and evaluation system

    International Nuclear Information System (INIS)

    Liu Tingjin

    1995-01-01

    The evaluation methods and Nuclear Data Evaluation System have been developed in China. A new version of the system has been established on Micro-VAX2 computer, which is supported by IAEA under the technology assistance program. The flow chart of Chinese Nuclear Data Evaluation System is shown out. For last ten years, the main efforts have been put on the double differential cross section, covariance data and evaluated data library validation. The developed evaluation method and Chinese Nuclear Data Evaluation System have been widely used at CNDC and in Chinese Nuclear Data Network for CENDL. (1 tab., 15 figs.)

  3. Evaluation method for acoustic trapping performance by tracking motion of trapped microparticle

    Science.gov (United States)

    Lim, Hae Gyun; Ham Kim, Hyung; Yoon, Changhan

    2018-05-01

    We report a method to evaluate the performances of a single-beam acoustic tweezer using a high-frequency ultrasound transducer. The motion of a microparticle trapped by a 45-MHz single-element transducer was captured and analyzed to deduce the magnitude of trapping force. In the proposed method, the motion of a trapped microparticle was analyzed from a series of microscopy images to compute trapping force; thus, no additional equipment such as microfluidics is required. The method could be used to estimate the effective trapping force in an acoustic tweezer experiment to assess cell membrane deformability by attaching a microbead to the surface of a cell and tracking the motion of the trapped bead, which is similar to a bead-based assay that uses optical tweezers. The results showed that the trapping force increased with increasing acoustic intensity and duty factor, but the force eventually reached a plateau at a higher acoustic intensity. They demonstrated that this method could be used as a simple tool to evaluate the performance and to optimize the operating conditions of acoustic tweezers.

  4. Comparative Study for Evaluation of Mass Flow Rate for Simple Solar Still and Active with Heat Pump

    OpenAIRE

    Hidouri Khaoula; Benhmidene Ali; Chaouachi Bechir; Ravishankar Sathyamurthy

    2017-01-01

    In isolated and arid areas, especially in the almost Maghreb regions, the abundant solar radiation intensity along the year and the available brackish water resources are the two favorable conditions for using solar desalination technology to produce fresh water. The present study is based on the use of three groups of correlation, for evaluating mass transfer. Theoretical results are compared with those obtained experimentally for a Simple Solar Distiller (SSD) and a Simple Solar Distiller H...

  5. A Simple and Effective Physical Characteristic Profiling Method for Methamphetamine Tablet Seized in China.

    Science.gov (United States)

    Li, Tao; Hua, Zhendong; Meng, Xin; Liu, Cuimei

    2018-03-01

    Methamphetamine (MA) tablet production confers chemical and physical properties. This study developed a simple and effective physical characteristic profiling method for MA tablets with capital letter "WY" logos, which realized the discrimination between linked and unlinked seizures. Seventeen signature distances extracted from the "WY" logo were explored as factors for multivariate analysis and demonstrated to be effective to represent the features of tablets in the drug intelligence perspective. Receiver operating characteristic (ROC) curve was used to evaluate efficiency of different pretreatments and distance/correlation metrics, while "Standardization + Euclidean" and "Logarithm + Euclidean" algorithms outperformed the rest. Finally, hierarchical cluster analysis (HCA) was applied to the data set of 200 MA tablet seizures randomly selected from cases all around China in 2015, and 76% of them were classified into a group named after "WY-001." Moreover, the "WY-001" tablets occupied 51-80% tablet seizures from 2011 to 2015 in China, indicating the existence of a huge clandestine factory incessantly manufacturing MA tablets. © 2017 American Academy of Forensic Sciences.

  6. Selections of minimal conditions for a simple intensification and scale up of w-transaminase reactions

    DEFF Research Database (Denmark)

    Gundersen, Maria T.; Lloyd, Richard C; Woodley, John

    A step wise decision matrix is presented to quickly evaluate w - transaminase for a ‘simple scale up’ in the synthetic direction . Here a ‘simple scale up’ is defined as a system without specialized equipment or process development, thus a rapid implementation . The three step method consists...

  7. A simple mass-conserved level set method for simulation of multiphase flows

    Science.gov (United States)

    Yuan, H.-Z.; Shu, C.; Wang, Y.; Shu, S.

    2018-04-01

    In this paper, a modified level set method is proposed for simulation of multiphase flows with large density ratio and high Reynolds number. The present method simply introduces a source or sink term into the level set equation to compensate the mass loss or offset the mass increase. The source or sink term is derived analytically by applying the mass conservation principle with the level set equation and the continuity equation of flow field. Since only a source term is introduced, the application of the present method is as simple as the original level set method, but it can guarantee the overall mass conservation. To validate the present method, the vortex flow problem is first considered. The simulation results are compared with those from the original level set method, which demonstrates that the modified level set method has the capability of accurately capturing the interface and keeping the mass conservation. Then, the proposed method is further validated by simulating the Laplace law, the merging of two bubbles, a bubble rising with high density ratio, and Rayleigh-Taylor instability with high Reynolds number. Numerical results show that the mass is a well-conserved by the present method.

  8. A simple, rapid, cost-effective and sensitive method for detection of Salmonella in environmental and pecan samples.

    Science.gov (United States)

    Dobhal, S; Zhang, G; Rohla, C; Smith, M W; Ma, L M

    2014-10-01

    PCR is widely used in the routine detection of foodborne human pathogens; however, challenges remain in overcoming PCR inhibitors present in some sample matrices. The objective of this study was to develop a simple, sensitive, cost-effective and rapid method for processing large numbers of environmental and pecan samples for Salmonella detection. This study was also aimed at validation of a new protocol for the detection of Salmonella from in-shell pecans. Different DNA template preparation methods, including direct boiling, prespin, multiple washing and commercial DNA extraction kits, were evaluated with pure cultures of Salmonella Typhimurium and with enriched soil, cattle feces and in-shell pecan each spiked individually with Salmonella Typhimurium. PCR detection of Salmonella was conducted using invA and 16S rRNA gene (internal amplification control) specific primers. The effect of amplification facilitators, including bovine serum albumin (BSA), polyvinylpyrrolidone (PVP), polyethylene glycol (PEG) and gelatin on PCR sensitivity, was also evaluated. Conducting a prespin of sample matrices in combination with the addition of 0·4% (w/v) BSA and 1% (w/v) PVP in PCR mix was the simplest, most rapid, cost-effective and sensitive method for PCR detection of Salmonella, with up to 40 CFU Salmonella per reaction detectable in the presence of over 10(9 ) CFU ml(-1) of background micro-organisms from enriched feces soil or pecan samples. The developed method is rapid, cost-effective and sensitive for detection of Salmonella from different matrices. This study provides a method with broad applicability for PCR detection of Salmonella in complex sample matrices. This method has a potential for its application in different research arenas and diagnostic laboratories. © 2014 The Society for Applied Microbiology.

  9. Bubble nucleation in simple and molecular liquids via the largest spherical cavity method

    International Nuclear Information System (INIS)

    Gonzalez, Miguel A.; Abascal, José L. F.; Valeriani, Chantal; Bresme, Fernando

    2015-01-01

    In this work, we propose a methodology to compute bubble nucleation free energy barriers using trajectories generated via molecular dynamics simulations. We follow the bubble nucleation process by means of a local order parameter, defined by the volume of the largest spherical cavity (LSC) formed in the nucleating trajectories. This order parameter simplifies considerably the monitoring of the nucleation events, as compared with the previous approaches which require ad hoc criteria to classify the atoms and molecules as liquid or vapor. The combination of the LSC and the mean first passage time technique can then be used to obtain the free energy curves. Upon computation of the cavity distribution function the nucleation rate and free-energy barrier can then be computed. We test our method against recent computations of bubble nucleation in simple liquids and water at negative pressures. We obtain free-energy barriers in good agreement with the previous works. The LSC method provides a versatile and computationally efficient route to estimate the volume of critical bubbles the nucleation rate and to compute bubble nucleation free-energies in both simple and molecular liquids

  10. Simple economic evaluation and applications experiments for photovoltaic systems for remote sites

    Energy Technology Data Exchange (ETDEWEB)

    Rios, M. Jr.

    1980-01-01

    A simple evaluation of the cost effectiveness of photovoltaic systems is presented. The evaluation is based on a calculation of breakeven costs of photovoltaics (PV) arrays with the levelized costs of two alternative energy sources (1) extension of the utility grid and (2) diesel generators. A selected number of PV applications experiments that are in progress in remote areas of the US are summarized. These applications experiments range from a 23 watt insect survey trap to a 100 kW PV system for a national park complex. It is concluded that PV systems for remote areas are now cost effective in remote small applications with commercially available technology and will be cost competitive for intermediate scale systems (approx. 10 kW) in the 1980s if the DOE 1986 Commercial Readiness Goals are achieved.

  11. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    OpenAIRE

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administer...

  12. A simple, rapid and inexpensive screening method for the identification of Pythium insidiosum.

    Science.gov (United States)

    Tondolo, Juliana Simoni Moraes; Loreto, Erico Silva; Denardi, Laura Bedin; Mario, Débora Alves Nunes; Alves, Sydney Hartz; Santurio, Janio Morais

    2013-04-01

    Growth of Pythium insidiosum mycelia around minocycline disks (30μg) did not occur within 7days of incubation at 35°C when the isolates were grown on Sabouraud, corn meal, Muller-Hinton or RPMI agar. This technique offers a simple and rapid method for the differentiation of P. insidiosum from true filamentous fungi. Copyright © 2013 Elsevier B.V. All rights reserved.

  13. Finding minimal action sequences with a simple evaluation of actions

    Science.gov (United States)

    Shah, Ashvin; Gurney, Kevin N.

    2014-01-01

    Animals are able to discover the minimal number of actions that achieves an outcome (the minimal action sequence). In most accounts of this, actions are associated with a measure of behavior that is higher for actions that lead to the outcome with a shorter action sequence, and learning mechanisms find the actions associated with the highest measure. In this sense, previous accounts focus on more than the simple binary signal of “was the outcome achieved?”; they focus on “how well was the outcome achieved?” However, such mechanisms may not govern all types of behavioral development. In particular, in the process of action discovery (Redgrave and Gurney, 2006), actions are reinforced if they simply lead to a salient outcome because biological reinforcement signals occur too quickly to evaluate the consequences of an action beyond an indication of the outcome's occurrence. Thus, action discovery mechanisms focus on the simple evaluation of “was the outcome achieved?” and not “how well was the outcome achieved?” Notwithstanding this impoverishment of information, can the process of action discovery find the minimal action sequence? We address this question by implementing computational mechanisms, referred to in this paper as no-cost learning rules, in which each action that leads to the outcome is associated with the same measure of behavior. No-cost rules focus on “was the outcome achieved?” and are consistent with action discovery. No-cost rules discover the minimal action sequence in simulated tasks and execute it for a substantial amount of time. Extensive training, however, results in extraneous actions, suggesting that a separate process (which has been proposed in action discovery) must attenuate learning if no-cost rules participate in behavioral development. We describe how no-cost rules develop behavior, what happens when attenuation is disrupted, and relate the new mechanisms to wider computational and biological context. PMID:25506326

  14. A Simple Method for Determination of Critical Swimming Velocity in Swimming Flume

    OpenAIRE

    高橋, 繁浩; 若吉, 浩二; Shigehiro, TAKAHASHI; Kohji, WAKAYOSHI; 中京大学; 奈良教育大学教育学部

    2001-01-01

    The purpose of this study was to investigate a simple method for determination of critical swimming velocity (Vcri). Vcri is defined by Wakayoshi et al. (1992) as the swimming speed which could theoretically be maintained forever without exhaustion, and is expressed as the slope of a regression line between swimming distance (D) and swimming time (T) obtained at various swimming speeds. To determine Vcri, 20 well-trained swimmers were measured at several swimming speeds ranging from 1.25 m/se...

  15. Translation, Cultural Adaptation and Validation of the Simple Shoulder Test to Spanish

    Science.gov (United States)

    Arcuri, Francisco; Barclay, Fernando; Nacul, Ivan

    2015-01-01

    Background: The validation of widely used scales facilitates the comparison across international patient samples. Objective: The objective was to translate, culturally adapt and validate the Simple Shoulder Test into Argentinian Spanish. Methods: The Simple Shoulder Test was translated from English into Argentinian Spanish by two independent translators, translated back into English and evaluated for accuracy by an expert committee to correct the possible discrepancies. It was then administered to 50 patients with different shoulder conditions.Psycometric properties were analyzed including internal consistency, measured with Cronbach´s Alpha, test-retest reliability at 15 days with the interclass correlation coefficient. Results: The internal consistency, validation, was an Alpha of 0,808, evaluated as good. The test-retest reliability index as measured by intra-class correlation coefficient (ICC) was 0.835, evaluated as excellent. Conclusion: The Simple Shoulder Test translation and it´s cultural adaptation to Argentinian-Spanish demonstrated adequate internal reliability and validity, ultimately allowing for its use in the comparison with international patient samples.

  16. Simple method for assembly of CRISPR synergistic activation mediator gRNA expression array.

    Science.gov (United States)

    Vad-Nielsen, Johan; Nielsen, Anders Lade; Luo, Yonglun

    2018-05-20

    When studying complex interconnected regulatory networks, effective methods for simultaneously manipulating multiple genes expression are paramount. Previously, we have developed a simple method for generation of an all-in-one CRISPR gRNA expression array. We here present a Golden Gate Assembly-based system of synergistic activation mediator (SAM) compatible CRISPR/dCas9 gRNA expression array for the simultaneous activation of multiple genes. Using this system, we demonstrated the simultaneous activation of the transcription factors, TWIST, SNAIL, SLUG, and ZEB1 a human breast cancer cell line. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. An evaluation of passive methods for measurement of radon in dwellings

    International Nuclear Information System (INIS)

    Strand, T.; Lind, B.; Kolstad, A.K.

    1989-01-01

    During the last ten years, different methods have been developed for the measurement of radon in indoor air. In this report the different methods in use by private firms in Norway have been compared. The results of the study show that the methods are quite different in regard to integration time, detection limit and reliability in measurements of radon in indoor air. In 1988 the National Institute of Radiation Hygiene gave directives on the performance of such measurements. In these directives, minimum limits have been set for integration time (7 days) for methods to be used in evaluations of remedial actions. In this report the results from a simple, anonymeous reliability test are reported. The test covered the private firms offering radon meassurement services in Norway. The frequently reported weaknesses by the charcoal method were confirmed in the study. The directives on radon measurements in dwellings are presented. 73 refs.; 11 figs.; 5 tabs

  18. A simple microplate-based method for the determination of α-amylase activity using the glucose assay kit (GOD method).

    Science.gov (United States)

    Visvanathan, Rizliya; Jayathilake, Chathuni; Liyanage, Ruvini

    2016-11-15

    For the first time, a reliable, simple, rapid and high-throughput analytical method for the detection and quantification of α-amylase inhibitory activity using the glucose assay kit was developed. The new method facilitates rapid screening of a large number of samples, reduces labor, time and reagents and is also suitable for kinetic studies. This method is based on the reaction of maltose with glucose oxidase (GOD) and the development of a red quinone. The test is done in microtitre plates with a total volume of 260μL and an assay time of 40min including the pre-incubation steps. The new method is tested for linearity, sensitivity, precision, reproducibility and applicability. The new method is also compared with the most commonly used 3,5-dinitrosalicylic acid (DNSA) method for determining α-amylase activity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Methadone radioimmunoassay: two simple methods

    International Nuclear Information System (INIS)

    Robinson, K.; Smith, R.N.

    1983-01-01

    Two simple and economical radioimmunoassays for methadone in blood or urine are described. Haemolysis, decomposition, common anticoagulants and sodium fluoride do not affect the results. One assay used commercially-available [1- 3 H](-)-methadone hydrobromide as the label, while the other uses a radioiodinated conjugate of 4-dimethylamino-2,2-diphenylpentanoic acid and L-tyrosine methyl ester. A commercially-available antiserum is used in both assays. Normethadone and α-methadol cross-react to a small extent with the antiserum while methadone metabolites, dextropropoxyphene, dipipanone and phenadoxone have negligible cross-reactivities. The 'cut-offs' of the two assays as described are 30 and 33 ng ml -1 for blood, and 24 and 21 ng ml -1 for urine. The assay using the radioiodinated conjugate can be made more sensitive if required by increasing the specific activity of the label. (author)

  20. A simple method to prolong the service life of radioactive sources for external radiotherapy.

    Science.gov (United States)

    Xu, Yingjie; Tian, Yuan; Dai, Jianrong

    2014-07-08

    A radioactive source is usually replaced and disposed after being used for a certain amount of time (usually a half-life). In this study, a simple method is proposed to prolong its service life. Instead of replacing the used source with a new source of full activity, a new source of less activity is added in the source holder in front of the used one, so that the total activity of two sources is equal to the initial activity of the used source or even higher. Similarly, more sources can be added to the previous ones. Attenuation of front source(s) to the back source(s) was evaluated with exponential attenuation equation, and variation of source-focus distance (SFD) with inverse square law for Leksell 4C Gamma Knife, which served as an example of external radiotherapy units. When the number of front sources increased from 1 to 3, the relative air kerma decreased from 36.5% to 5.0%. Both the attenuation effect and SFD variation contributed to the decrease in air kerma, with the former being the major factor. If the height of the source can be decreased in some way, such as increasing the specific activity of sources, the sources can be used more efficiently. The method prolongs the service life of sources by several factors, and reduces the expense of source exchange and reclamation.

  1. A simple method for fabricating multi-layer PDMS structures for 3D microfluidic chips

    KAUST Repository

    Zhang, Mengying

    2010-01-01

    We report a simple methodology to fabricate PDMS multi-layer microfluidic chips. A PDMS slab was surface-treated by trichloro (1H,1H,2H,2H-perfluorooctyl) silane, and acts as a reusable transferring layer. Uniformity of the thickness of the patterned PDMS layer and the well-alignment could be achieved due to the transparency and proper flexibility of this transferring layer. Surface treatment results are confirmed by XPS and contact angle testing, while bonding forces between different layers were measured for better understanding of the transferring process. We have also designed and fabricated a few simple types of 3D PDMS chip, especially one consisting of 6 thin layers (each with thickness of 50 μm), to demonstrate the potential utilization of this technique. 3D fluorescence images were taken by a confocal microscope to illustrate the spatial characters of essential parts. This fabrication method is confirmed to be fast, simple, repeatable, low cost and possible to be mechanized for mass production. © The Royal Society of Chemistry 2010.

  2. A simple method for rapidly processing HEU from weapons returns

    Energy Technology Data Exchange (ETDEWEB)

    McLean, W. II; Miller, P.E.

    1994-01-01

    A method based on the use of a high temperature fluidized bed for rapidly oxidizing, homogenizing and down-blending Highly Enriched Uranium (HEU) from dismantled nuclear weapons is presented. This technology directly addresses many of the most important issues that inhibit progress in international commerce in HEU; viz., transaction verification, materials accountability, transportation and environmental safety. The equipment used to carry out the oxidation and blending is simple, inexpensive and highly portable. Mobile facilities to be used for point-of-sale blending and analysis of the product material are presented along with a phased implementation plan that addresses the conversion of HEU derived from domestic weapons and related waste streams as well as material from possible foreign sources such as South Africa or the former Soviet Union.

  3. A simple method to estimate radiation interception by nursery stock conifers: a case study of eastern white cedar

    NARCIS (Netherlands)

    Pronk, A.A.; Goudriaan, J.; Stilma, E.S.C.; Challa, H.

    2003-01-01

    A simple method was developed to estimate the fraction radiation intercepted by small eastern white cedar plants (Thuja occidentalis 'Brabant'). The method, which describes the crop canopy as rows of cuboids, was compared with methods used for estimating radiation interception by crops with

  4. A simple method for assigning genomic grade to individual breast tumours

    International Nuclear Information System (INIS)

    Wennmalm, Kristian; Bergh, Jonas

    2011-01-01

    The prognostic value of grading in breast cancer can be increased with microarray technology, but proposed strategies are disadvantaged by the use of specific training data or parallel microscopic grading. Here, we investigate the performance of a method that uses no information outside the breast profile of interest. In 251 profiled tumours we optimised a method that achieves grading by comparing rank means for genes predictive of high and low grade biology; a simpler method that allows for truly independent estimation of accuracy. Validation was carried out in 594 patients derived from several independent data sets. We found that accuracy was good: for low grade (G1) tumors 83- 94%, for high grade (G3) tumors 74- 100%. In keeping with aim of improved grading, two groups of intermediate grade (G2) cancers with significantly different outcome could be discriminated. This validates the concept of microarray-based grading in breast cancer, and provides a more practical method to achieve it. A simple R script for grading is available in an additional file. Clinical implementation could achieve better estimation of recurrence risk for 40 to 50% of breast cancer patients

  5. A simple method for assigning genomic grade to individual breast tumours

    Directory of Open Access Journals (Sweden)

    Bergh Jonas

    2011-07-01

    Full Text Available Abstract Background The prognostic value of grading in breast cancer can be increased with microarray technology, but proposed strategies are disadvantaged by the use of specific training data or parallel microscopic grading. Here, we investigate the performance of a method that uses no information outside the breast profile of interest. Results In 251 profiled tumours we optimised a method that achieves grading by comparing rank means for genes predictive of high and low grade biology; a simpler method that allows for truly independent estimation of accuracy. Validation was carried out in 594 patients derived from several independent data sets. We found that accuracy was good: for low grade (G1 tumors 83- 94%, for high grade (G3 tumors 74- 100%. In keeping with aim of improved grading, two groups of intermediate grade (G2 cancers with significantly different outcome could be discriminated. Conclusion This validates the concept of microarray-based grading in breast cancer, and provides a more practical method to achieve it. A simple R script for grading is available in an additional file. Clinical implementation could achieve better estimation of recurrence risk for 40 to 50% of breast cancer patients.

  6. Training nuclei detection algorithms with simple annotations

    Directory of Open Access Journals (Sweden)

    Henning Kost

    2017-01-01

    Full Text Available Background: Generating good training datasets is essential for machine learning-based nuclei detection methods. However, creating exhaustive nuclei contour annotations, to derive optimal training data from, is often infeasible. Methods: We compared different approaches for training nuclei detection methods solely based on nucleus center markers. Such markers contain less accurate information, especially with regard to nuclear boundaries, but can be produced much easier and in greater quantities. The approaches use different automated sample extraction methods to derive image positions and class labels from nucleus center markers. In addition, the approaches use different automated sample selection methods to improve the detection quality of the classification algorithm and reduce the run time of the training process. We evaluated the approaches based on a previously published generic nuclei detection algorithm and a set of Ki-67-stained breast cancer images. Results: A Voronoi tessellation-based sample extraction method produced the best performing training sets. However, subsampling of the extracted training samples was crucial. Even simple class balancing improved the detection quality considerably. The incorporation of active learning led to a further increase in detection quality. Conclusions: With appropriate sample extraction and selection methods, nuclei detection algorithms trained on the basis of simple center marker annotations can produce comparable quality to algorithms trained on conventionally created training sets.

  7. A simple method for improving predictions of nuclear masses

    International Nuclear Information System (INIS)

    Yamada, Masami; Tsuchiya, Susumu; Tachibana, Takahiro

    1991-01-01

    The formula for atomic masses which exactly conforms to all nuclides does not exist in reality and cannot be anticipated for the time being hereafter. At present the masses of many nuclides are known experimentally with good accuracy, but the values of whichever mass formulas are more or less different from those experimental values except small number of accidental coincidence. Under such situation, for forecasting the mass of an unknown nuclide, how is it cleverly done ? Generally speaking, to take the value itself of a mass formula seems not the best means. It may be better to take the difference of the values of a mass formula and experiment for the nuclide close to that to be forecast in consideration and to correct the forecast value of the mass formula. In this report, the simple method for this correction is proposed. The formula which connects between two extreme cases, the difference between a true mass and the value of a mass formula is the sum of proton part and neutron part, and the difference distributes randomly around zero, was proposed. The procedure for its concrete application is explained. This method can be applied to other physical quantities than mass, for example the half life of beta decay. (K.I.)

  8. Variation of ratio kinetic profiles as a simple and novel spectrophotometric method for the simultaneous kinetic analysis of binary mixtures

    Directory of Open Access Journals (Sweden)

    Naseri Abdolhossein

    2012-01-01

    Full Text Available In this paper, a new and very simple kinetic - spectrophotometric method is developed for the simultaneous determination of binary mixtures without prior separational steps. The method is based on the calculation of the variation of ratio kinetic profiles. The mathematical explanation of the procedure is also illustrated. The proposed method can be used for simultaneous determination of two analytes A and B that react with the same reagent to give the same absorbing species. In order to evaluate the applicability of the method, a model data as well as an experimental data were tested. The results from experimental data relating to the simultaneous spectrophotometric determination of Co (II and V (IV based on their oxidation reactions with Fe (III in the presence 1, 10- Phenanthroline (Phen in micellar media were presented as a real model for resolution of the binary systems. The applicability of the method in tap water and synthesized alloy samples was also assessed by spiking experiments with different amount of Co (II and V (IV.

  9. A Convergence Result for the Euler-Maruyama Method for a Simple Stochastic Differential Equation with Discontinuous Drift

    DEFF Research Database (Denmark)

    Simonsen, Maria; Schiøler, Henrik; Leth, John-Josef

    2014-01-01

    The Euler-Maruyama method is applied to a simple stochastic differential equation (SDE) with discontinuous drift. Convergence aspects are investigated in the case, where the Euler-Maruyama method is simulated in dyadic points. A strong rate of convergence is presented for the numerical simulations...

  10. Morphology-based Enhancement of a French SIMPLE Lexicon

    OpenAIRE

    Namer , Fiammetta; Bouillon , Pierrette; Jacquey , Evelyne; Ruimy , Nilda

    2009-01-01

    International audience; In this paper, we propose a semi-automatic methodology for acquiring a French SIMPLE lexicon based on the morphological properties of complex words. This method combines the results of the French morphological analyzer DériF with infor-mation from general lexical resources and corpora, when available. It is evaluated on a set of neolo-gisms extracted from Le Monde newspaper cor-pora.

  11. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use

    OpenAIRE

    Robitaille, Line; Hoffer, L. John

    2016-01-01

    Background In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Methods Plasma vitamin C can be analyzed by high performance liquid chro...

  12. A simple method for the measurement of reflective foil emissivity

    International Nuclear Information System (INIS)

    Ballico, M. J.; Ham, E. W. M. van der

    2013-01-01

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to 'bubble-wrap'. Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a 'primary method' and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408

  13. A simple method for the measurement of reflective foil emissivity

    Science.gov (United States)

    Ballico, M. J.; van der Ham, E. W. M.

    2013-09-01

    Reflective metal foil is widely used to reduce radiative heat transfer within the roof space of buildings. Such foils are typically mass-produced by vapor-deposition of a thin metallic coating onto a variety of substrates, ranging from plastic-coated reinforced paper to "bubble-wrap". Although the emissivity of such surfaces is almost negligible in the thermal infrared, typically less than 0.03, an insufficiently thick metal coating, or organic contamination of the surface, can significantly increase this value. To ensure that the quality of the installed insulation is satisfactory, Australian building code AS/NZS 4201.5:1994 requires a practical agreed method for measurement of the emissivity, and the standard ASTM-E408 is implied. Unfortunately this standard is not a "primary method" and requires the use of specified expensive apparatus and calibrated reference materials. At NMIA we have developed a simple primary technique, based on an apparatus to thermally modulate the sample and record the apparent modulation in infra-red radiance with commercially available radiation thermometers. The method achieves an absolute accuracy in the emissivity of approximately 0.004 (k=2). This paper theoretically analyses the equivalence between the thermal emissivity measured in this manner, the effective thermal emissivity in application, and the apparent emissivity measured in accordance with ASTM-E408.

  14. Feasibility of testing DNA repair inhibitors for mutagenicity by a simple method

    International Nuclear Information System (INIS)

    Sideropoulos, A.S.; Specht, S.M.; Jones, M.T.

    1980-01-01

    A simple screening methodology for the determination of mutagenicity of DNA repair inhibitors has been tested in this laboratory. Radiation-resistant E. coli B/r and WP2 hcr + and hcr - are suitable strains for mutagenicity testing. In these strains irradiated with 40-60 ergs/mm 2 , chemicals which interfere with repair of ultraviolet-induced pre-mutational lesions can be shown to enhance significantly the frequency of mutations to streptomycin resistance. This phenomenon is termed 'mutational synergism' [18,20]. We have attempted to apply the procedure for securing data for 'mutational synergism' between ultraviolet (UV) radiation and a number of antimalarial drugs including quinine hydrochloride (50 μg/ml), quinine hydrobromide (50 μg/ml), primaquine diphosphate (50 μg/ml), chloroquine (50 μg/ml), quinine (50 μg/ml) and quinacrine dihydrochloride (25 μg/ml). All drugs tested give synergistic effects with UV light. The synergistic activity ranges from 3- to 35-fold. Quinine and quinacrine dihydrochloride have been found to be much more efficient enhancers of the mutagenic effect of UV than caffeine. In general, we have found that the expression of synergistic action occurs at a concentration well below the minimum inhibitory concentration (MIC) with the drugs tested. The implication of these observations in the establishment of a screening method for the evaluation of the mutagenicity of DNA repair inhibitors is discussed. (orig.)

  15. Feasibility of testing DNA repair inhibitors for mutagenicity by a simple method

    International Nuclear Information System (INIS)

    Sideropoulos, A.S.; Specht, S.M.; Jones, M.T.

    1980-01-01

    A simple screening methodology for the determination of mutagenictity of DNA repair inhibitors has been tested in this laboratory. Radiation-resistant E. coli B/r and WP2 hcr + and hcr - are suitable strains for mutagenicity testing. In these strains irradiated with 40-60 ergs/mm 2 , chemicals which interfere with repair of ultraviolet-induced pre-mutational lesions can be shown to enhance significantly the frequency of mutations to streptomycin resistance. This phenomenon is termed mutational synergism. We have attempted to apply the procedure for securing data for mutational synergism between ultraviolet (UV) radiation and a number of antimalarial drugs including quinine hydrochloride (50 μg/ml), quinine hydrobromide (50 μg/ml), primaquine diphosphate (50 μg/ml), chloroquine (50μg/ml) and quinacrine dihydrochloride (25 μg/ml). All drugs tested give synergistic effets with UV light. The synergistic activity ranges from 3- to 35-fold. Quinine and quinacrine dihydrochloride have been found to be much more efficient enhancers of the mutagenic effect of UV than caffeine. In general, we have found that the expression of synergistic action occurs at a concentration well below the minimum inhibitory concentration (MIC) with the drugs tested. The implication of these observations in the establishment of a screening method for the evaluation of the mutagenicity of DNA repair inhibitors is discussed. (orig.)

  16. Feasibility of testing DNA repair inhibitors for mutagenicity by a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Sideropoulos, A S; Specht, S M; Jones, M T [Duquesne Univ., Pittsburgh, PA (USA). Dept. of Biological Sciences

    1980-04-01

    A simple screening methodology for the determination of mutagenictity of DNA repair inhibitors has been tested in this laboratory. Radiation-resistant E. coli B/r and WP2 hcr/sup +/ and hcr/sup -/ are suitable strains for mutagenicity testing. In these strains irradiated with 40-60 ergs/mm/sup 2/, chemicals which interfere with repair of ultraviolet-induced pre-mutational lesions can be shown to enhance significantly the frequency of mutations to streptomycin resistance. This phenomenon is termed mutational synergism. We have attempted to apply the procedure for securing data for mutational synergism between ultraviolet (uv) radiation and a number of antimalarial drugs including quinine hydrochloride (50 ..mu..g/ml), quinine hydrobromide (50 ..mu..g/ml), primaquine diphosphate (50 ..mu..g/ml), chloroquine (50..mu..g/ml) and quinacrine dihydrochloride (25 ..mu..g/ml). All drugs tested give synergistic effects with uv light. The synergistic activity ranges from 3- to 35-fold. Quinine and quinacrine dihydrochloride have been found to be much more efficient enhancers of the mutagenic effect of uv than caffeine. In general, we have found that the expression of synergistic action occurs at a concentration well below the minimum inhibitory concentration (MIC) with the drugs tested. The implication of these observations in the establishment of a screening method for the evaluation of the mutagenicity of DNA repair inhibitors is discussed.

  17. Feasibility of testing DNA repair inhibitors for mutagenicity by a simple method

    Energy Technology Data Exchange (ETDEWEB)

    Sideropoulos, A S; Specht, S M; Jones, M T [Duquesne Univ., Pittsburgh, PA (USA). Dept. of Biological Sciences

    1980-04-01

    A simple screening methodology for the determination of mutagenicity of DNA repair inhibitors has been tested in this laboratory. Radiation-resistant E. coli B/r and WP2 hcr/sup +/ and hcr/sup -/ are suitable strains for mutagenicity testing. In these strains irradiated with 40-60 ergs/mm/sup 2/, chemicals which interfere with repair of ultraviolet-induced pre-mutational lesions can be shown to enhance significantly the frequency of mutations to streptomycin resistance. This phenomenon is termed 'mutational synergism' (18,20). We have attempted to apply the procedure for securing data for 'mutational synergism' between ultraviolet (UV) radiation and a number of antimalarial drugs including quinine hydrochloride (50 ..mu..g/ml), quinine hydrobromide (50 ..mu..g/ml), primaquine diphosphate (50 ..mu..g/ml), chloroquine (50 ..mu..g/ml), quinine (50 ..mu..g/ml) and quinacrine dihydrochloride (25 ..mu..g/ml). All drugs tested give synergistic effects with UV light. The synergistic activity ranges from 3- to 35-fold. Quinine and quinacrine dihydrochloride have been found to be much more efficient enhancers of the mutagenic effect of UV than caffeine. In general, we have found that the expression of synergistic action occurs at a concentration well below the minimum inhibitory concentration (MIC) with the drugs tested. The implication of these observations in the establishment of a screening method for the evaluation of the mutagenicity of DNA repair inhibitors is discussed.

  18. Evaluation methods for hospital facilities

    DEFF Research Database (Denmark)

    Fronczek-Munter, Aneta

    2013-01-01

    according to focus areas and proposes which evaluation methods to use in different building phases of healthcare facilities. Hospital evaluations with experts and users are also considered; their subjective view on space, function, technology, usability and aesthetics. Results & solutions: This paper...... presents the different methods for evaluating buildings in use in a new model, the Evaluation Focus Flower, and proposes which evaluation methods are suitable for various aims and building phases, i.e. which is giving best input for the initial briefing process of new hospital facilities with ambition...... of creating buildings with enhanced usability. Additionally various evaluation methods used in hospital cases in Denmark and Norway are presented. Involvement of users is proposed, not just in defining requirements but also in co-creation/design and evaluation of solutions. The theories and preliminary...

  19. A simple method to calculate the influence of dose inhomogeneity and fractionation in normal tissue complication probability evaluation

    International Nuclear Information System (INIS)

    Begnozzi, L.; Gentile, F.P.; Di Nallo, A.M.; Chiatti, L.; Zicari, C.; Consorti, R.; Benassi, M.

    1994-01-01

    Since volumetric dose distributions are available with 3-dimensional radiotherapy treatment planning they can be used in statistical evaluation of response to radiation. This report presents a method to calculate the influence of dose inhomogeneity and fractionation in normal tissue complication probability evaluation. The mathematical expression for the calculation of normal tissue complication probability has been derived combining the Lyman model with the histogram reduction method of Kutcher et al. and using the normalized total dose (NTD) instead of the total dose. The fitting of published tolerance data, in case of homogeneous or partial brain irradiation, has been considered. For the same total or partial volume homogeneous irradiation of the brain, curves of normal tissue complication probability have been calculated with fraction size of 1.5 Gy and of 3 Gy instead of 2 Gy, to show the influence of fraction size. The influence of dose distribution inhomogeneity and α/β value has also been simulated: Considering α/β=1.6 Gy or α/β=4.1 Gy for kidney clinical nephritis, the calculated curves of normal tissue complication probability are shown. Combining NTD calculations and histogram reduction techniques, normal tissue complication probability can be estimated taking into account the most relevant contributing factors, including the volume effect. (orig.) [de

  20. Note: A simple image processing based fiducial auto-alignment method for sample registration.

    Science.gov (United States)

    Robertson, Wesley D; Porto, Lucas R; Ip, Candice J X; Nantel, Megan K T; Tellkamp, Friedjof; Lu, Yinfei; Miller, R J Dwayne

    2015-08-01

    A simple method for the location and auto-alignment of sample fiducials for sample registration using widely available MATLAB/LabVIEW software is demonstrated. The method is robust, easily implemented, and applicable to a wide variety of experiment types for improved reproducibility and increased setup speed. The software uses image processing to locate and measure the diameter and center point of circular fiducials for distance self-calibration and iterative alignment and can be used with most imaging systems. The method is demonstrated to be fast and reliable in locating and aligning sample fiducials, provided here by a nanofabricated array, with accuracy within the optical resolution of the imaging system. The software was further demonstrated to register, load, and sample the dynamically wetted array.

  1. An Operationally Simple Method for Separating the Rare-Earth Elements Neodymium and Dysprosium.

    Science.gov (United States)

    Bogart, Justin A; Lippincott, Connor A; Carroll, Patrick J; Schelter, Eric J

    2015-07-06

    Rare-earth metals are critical components of electronic materials and permanent magnets. Recycling of consumer materials is a promising new source of rare earths. To incentivize recycling there is a clear need for simple methods for targeted separations of mixtures of rare-earth metal salts. Metal complexes of a tripodal nitroxide ligand [{(2-(t) BuNO)C6 H4 CH2 }3 N](3-) (TriNOx(3-) ), feature a size-sensitive aperture formed of its three η(2) -(N,O) ligand arms. Exposure of metal cations in the aperture induces a self-associative equilibrium comprising [M(TriNOx)thf]/ [M(TriNOx)]2 (M=rare-earth metal). Differences in the equilibrium constants (Keq ) for early and late metals enables simple Nd/Dy separations through leaching with a separation ratio SNd/Dy =359. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Simple neck pain questions used in surveys, evaluated in relation to health outcomes: a cohort study

    Science.gov (United States)

    2012-01-01

    Background The high prevalence of pain reported in many epidemiological studies, and the degree to which this prevalence reflects severe pain is under discussion in the literature. The aim of the present study was to evaluate use of the simple neck pain questions commonly included in large epidemiological survey studies with respect to aspects of health. We investigated if and how an increase in number of days with pain is associated with reduction in health outcomes. Methods A cohort of university students (baseline age 19–25 years) were recruited in 2002 and followed annually for 4 years. The baseline response rate was 69% which resulted in 1200 respondents (627 women, 573 men). Participants were asked about present and past pain and perceptions of their general health, sleep disturbance, stress and energy levels, and general performance. The data were analyzed using a mixed model for repeated measurements and a random intercept logistic model. Results When reporting present pain, participants also reported lower prevalence of very good health, higher stress and sleep disturbance scores and lower energy score. Among those with current neck pain, additional questions characterizing the pain such as duration (categorized), additional pain sites and decreased general performance were associated with lower probability of very good health and higher amounts of sleep disturbance. Knowing about the presence or not of pain explains more of the variation in health between individuals, than within individuals. Conclusion This study of young university students has demonstrated that simple neck pain survey questions capture features of pain that affect aspects of health such as perceived general health, sleep disturbance, mood in terms of stress and energy. Simple pain questions are more useful for group descriptions than for describing or following pain in an individual. PMID:23102060

  3. Simple neck pain questions used in surveys, evaluated in relation to health outcomes: a cohort study

    Directory of Open Access Journals (Sweden)

    Grimby-Ekman Anna

    2012-10-01

    Full Text Available Abstract Background The high prevalence of pain reported in many epidemiological studies, and the degree to which this prevalence reflects severe pain is under discussion in the literature. The aim of the present study was to evaluate use of the simple neck pain questions commonly included in large epidemiological survey studies with respect to aspects of health. We investigated if and how an increase in number of days with pain is associated with reduction in health outcomes. Methods A cohort of university students (baseline age 19–25 years were recruited in 2002 and followed annually for 4 years. The baseline response rate was 69% which resulted in 1200 respondents (627 women, 573 men. Participants were asked about present and past pain and perceptions of their general health, sleep disturbance, stress and energy levels, and general performance. The data were analyzed using a mixed model for repeated measurements and a random intercept logistic model. Results When reporting present pain, participants also reported lower prevalence of very good health, higher stress and sleep disturbance scores and lower energy score. Among those with current neck pain, additional questions characterizing the pain such as duration (categorized, additional pain sites and decreased general performance were associated with lower probability of very good health and higher amounts of sleep disturbance. Knowing about the presence or not of pain explains more of the variation in health between individuals, than within individuals. Conclusion This study of young university students has demonstrated that simple neck pain survey questions capture features of pain that affect aspects of health such as perceived general health, sleep disturbance, mood in terms of stress and energy. Simple pain questions are more useful for group descriptions than for describing or following pain in an individual.

  4. Slope stability and bearing capacity of landfills and simple on-site test methods.

    Science.gov (United States)

    Yamawaki, Atsushi; Doi, Yoichi; Omine, Kiyoshi

    2017-07-01

    This study discusses strength characteristics (slope stability, bearing capacity, etc.) of waste landfills through on-site tests that were carried out at 29 locations in 19 sites in Japan and three other countries, and proposes simple methods to test and assess the mechanical strength of landfills on site. Also, the possibility of using a landfill site was investigated by a full-scale eccentric loading test. As a result of this, landfills containing more than about 10 cm long plastics or other fibrous materials were found to be resilient and hard to yield. An on-site full scale test proved that no differential settlement occurs. The repose angle test proposed as a simple on-site test method has been confirmed to be a good indicator for slope stability assessment. The repose angle test suggested that landfills which have high, near-saturation water content have considerably poorer slope stability. The results of our repose angle test and the impact acceleration test were related to the internal friction angle and the cohesion, respectively. In addition to this, it was found that the air pore volume ratio measured by an on-site air pore volume ratio test is likely to be related to various strength parameters.

  5. Experimental guinea pig model of dermatophytosis: a simple and useful tool for the evaluation of new diagnostics and antifungals

    DEFF Research Database (Denmark)

    Saunte, D.M.; Hasselby, J.P.; Brillowska-Dabrowska, A.

    2008-01-01

    The aim of this study was to establish a simple guinea pig model for the purpose of evaluating diagnostic principles and treatment modalities for dermatophytic infections. The following variables were evaluated; pre-treatment of the skin by shaving versus tape stripping, Microsporum canis...

  6. Simple time-saving method for iron determination based on fluorescence quenching of an azaflavanon-3-ol compound.

    Science.gov (United States)

    Başoğlu, Aysel; Tosun, Gonca; Ocak, Miraç; Alp, Hakan; Yaylı, Nurettin; Ocak, Ümmühan

    2015-03-18

    A simple and time-saving spectrofluorometric method developed using an azaflavanon-3-ol compound was used for the determination of iron in various food samples. Nitric acid and hydrogen peroxide were used for digestion of samples in a closed microwave system. The method was validated by analyzing two certified reference materials (CRM-SA-C Sandy Soil C and Mixed Polish Herbs INCT-MPH-2). Measurements were carried out using a modified standard addition method. The standard addition graph was linear until 21.6 mg/L in the determination of iron(III). Detection and quantification limits were 0.81 and 2.4 mg/L, respectively. Satisfactory accuracy was obtained for spinach, dill, mint, purslane, rocket, red lentils, dry beans, and two iron medicinal tablets. High recoveries were found for streamwater samples fortified at three different concentrations. The method is simple, time-saving, cost-effective, and suitable for the determination of the iron content of foods.

  7. Simple method of generating and distributing frequency-entangled qudits

    Science.gov (United States)

    Jin, Rui-Bo; Shimizu, Ryosuke; Fujiwara, Mikio; Takeoka, Masahiro; Wakabayashi, Ryota; Yamashita, Taro; Miki, Shigehito; Terai, Hirotaka; Gerrits, Thomas; Sasaki, Masahide

    2016-11-01

    High-dimensional, frequency-entangled photonic quantum bits (qudits for d-dimension) are promising resources for quantum information processing in an optical fiber network and can also be used to improve channel capacity and security for quantum communication. However, up to now, it is still challenging to prepare high-dimensional frequency-entangled qudits in experiments, due to technical limitations. Here we propose and experimentally implement a novel method for a simple generation of frequency-entangled qudts with d\\gt 10 without the use of any spectral filters or cavities. The generated state is distributed over 15 km in total length. This scheme combines the technique of spectral engineering of biphotons generated by spontaneous parametric down-conversion and the technique of spectrally resolved Hong-Ou-Mandel interference. Our frequency-entangled qudits will enable quantum cryptographic experiments with enhanced performances. This distribution of distinct entangled frequency modes may also be useful for improved metrology, quantum remote synchronization, as well as for fundamental test of stronger violation of local realism.

  8. A simple method to estimate radiation interception by nursery stock conifers: a case study of eastern white cedar

    International Nuclear Information System (INIS)

    Pronk, A.A.; Goudriaan, J.; Stilma, E.; Challa, H.

    2003-01-01

    A simple method was developed to estimate the fraction radiation intercepted by small eastern white cedar plants (Thuja occidentalis ‘Brabant’). The method, which describes the crop canopy as rows of cuboids, was compared with methods used for estimating radiation interception by crops with homogeneous canopies and crops grown in rows. The extinction coefficient k was determined at different plant arrangements and an average k-value of 0.48 ± 0.03 (R 2 = 0.89) was used in the calculations. Effects of changing plant characteristics and inter- and intra-row plant distances were explored. The fraction radiation intercepted that was estimated with the method for rows of cuboids was up to 20% and for row crops up to 8% lower than estimated with the method for homogeneous canopies at low plant densities and a LAI of 1. The fraction radiation intercepted by small plants of Thuja occidentalis ‘Brabant’ was best estimated by the simple method described in this paper

  9. Methods for evaluating imaging methods of limited reproducibility

    International Nuclear Information System (INIS)

    Krummenauer, F.

    2005-01-01

    Just like new drugs, new or modified imaging methods must be subjected to objective clinical tests, including tests on humans. In this, it must be ensured that the principle of Good Clinical Practice (GCP) are followed with regard to medical, administrative and methodical quality. Innovative methods fo clinical epidemiology and medical biometry should be applied from the planning stage to the final statistical evaluation. The author presents established and new methods for planning, evaluation and reporting of clinical tests of diagnostic methods, and especially imaging methods, in clinical medicine and illustrates these by means of current research projects in the various medical disciplines. The strategies presented are summarized in a recommendation based on the concept of phases I - IV of clinical drug testing in order to enable standardisation of the clinical evaluation of imaging methods. (orig.)

  10. Probabilistic evaluation method of stability of ground and slope considering spatial randomness of soil properties

    International Nuclear Information System (INIS)

    Ohtori, Yasuki

    2004-01-01

    In the JEAG4601-1987 (Japan Electric Association Guide for earthquake resistance design), either the conventional deterministic method or probabilistic method is used for evaluating the stability of ground foundations and surrounding slopes in nuclear power plants. The deterministic method, in which the soil properties of 'mean ± coefficient x standard deviation' is adopted for the calculations, is generally used in the design stage to data. On the other hand, the probabilistic method, in which the soil properties assume to have probabilistic distributions, is stated as a future method. The deterministic method facilitates the evaluation, however, it is necessary to clarify the relation with the probabilistic method. In this paper, the relationship between the deterministic and the probabilistic methods are investigated. To do that, a simple model that can take into account the dynamic effect of structures and a simplified method for accounting the spatial randomness are proposed and used for the studies. As the results of studies, it is found that the strength of soil properties is most importation factor for the stability of ground structures and the probability below the safety factor evaluated with the soil properties of mean -1.0 x standard deviation' by the deterministic method is of much lower. (author)

  11. A simple method to take urethral sutures for neobladder reconstruction and radical prostatectomy

    Directory of Open Access Journals (Sweden)

    B Satheesan

    2007-01-01

    Full Text Available For the reconstruction of urethra-vesical anastamosis after radical prostatectomy and for neobladder reconstruction, taking adequate sutures to include the urethral mucosa is vital. Due to the retraction of the urethra and unfriendly pelvis, the process of taking satisfactory urethral sutures may be laborious. Here, we describe a simple method by which we could overcome similar technical problems during surgery using Foley catheter as the guide for the suture.

  12. Simple turbulence measurements with azopolymer thin films.

    Science.gov (United States)

    Barillé, Regis; Pérez, Darío G; Morille, Yohann; Zielińska, Sonia; Ortyl, Ewelina

    2013-04-01

    A simple method to measure the influence on the laser beam propagation by a turbid medium is proposed. This measurement is based on the inscription of a surface relief grating (SRG) on an azopolymer thin film. The grating obtained with a single laser beam after propagation into a turbulent medium is perturbed and directly analyzed by a CCD camera through its diffraction pattern. Later, by scanning the surface pattern with an atomic force microscope, the inscribed SRG is analyzed with the Radon transform. This method has the advantage of using a single beam to remotely inscribe a grating detecting perturbations during the beam path. A method to evaluate the refractive index constant structure is developed.

  13. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    International Nuclear Information System (INIS)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T.; Guharay, S.K.

    1997-01-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H - ) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  14. Simple emittance measurement of negative hydrogen ion beam using pepper-pot method

    Energy Technology Data Exchange (ETDEWEB)

    Hamabe, M.; Tsumori, K.; Takeiri, Y.; Kaneko, O.; Asano, E.; Kawamoto, T.; Kuroda, T. [National Inst. for Fusion Science, Nagoya (Japan); Guharay, S.K.

    1997-02-01

    A simple apparatus for emittance measurement using pepper-pot method is developed. The pepper-pot patterns are directly exposed and recorded on a Kapton foil. Using this apparatus, emittance was measured in the case of the negative hydrogen (H{sup -}) beam from the large negative ion source, which is the 1/3 scaled test device for the negative-ion-based neutral beam injection (N-NBI) on the Large Helical Device (LHD). As the consequence of the first trial, the 95% normalized emittance value is measured as 0.59 mm mrad. (author)

  15. Power-law behaviour evaluation from foreign exchange market data using a wavelet transform method

    Science.gov (United States)

    Wei, H. L.; Billings, S. A.

    2009-09-01

    Numerous studies in the literature have shown that the dynamics of many time series including observations in foreign exchange markets exhibit scaling behaviours. A simple new statistical approach, derived from the concept of the continuous wavelet transform correlation function (WTCF), is proposed for the evaluation of power-law properties from observed data. The new method reveals that foreign exchange rates obey power-laws and thus belong to the class of self-similarity processes.

  16. Power-law behaviour evaluation from foreign exchange market data using a wavelet transform method

    Energy Technology Data Exchange (ETDEWEB)

    Wei, H.L., E-mail: w.hualiang@sheffield.ac.u [Department of Automatic Control and Systems Engineering, the University of Sheffield, Mappin Street, Sheffield, S1 3JD (United Kingdom); Billings, S.A., E-mail: s.billings@sheffield.ac.u [Department of Automatic Control and Systems Engineering, the University of Sheffield, Mappin Street, Sheffield, S1 3JD (United Kingdom)

    2009-09-07

    Numerous studies in the literature have shown that the dynamics of many time series including observations in foreign exchange markets exhibit scaling behaviours. A simple new statistical approach, derived from the concept of the continuous wavelet transform correlation function (WTCF), is proposed for the evaluation of power-law properties from observed data. The new method reveals that foreign exchange rates obey power-laws and thus belong to the class of self-similarity processes.

  17. Power-law behaviour evaluation from foreign exchange market data using a wavelet transform method

    International Nuclear Information System (INIS)

    Wei, H.L.; Billings, S.A.

    2009-01-01

    Numerous studies in the literature have shown that the dynamics of many time series including observations in foreign exchange markets exhibit scaling behaviours. A simple new statistical approach, derived from the concept of the continuous wavelet transform correlation function (WTCF), is proposed for the evaluation of power-law properties from observed data. The new method reveals that foreign exchange rates obey power-laws and thus belong to the class of self-similarity processes.

  18. Simple method to transfer graphene from metallic catalytic substrates to flexible surfaces without chemical etching

    International Nuclear Information System (INIS)

    Ko, P J; Takahashi, H; Sakai, H; Thu, T V; Okada, H; Sandhu, A; Koide, S

    2013-01-01

    Graphene shows promise for applications in flexible electronics. Here, we describe our procedure to transfer graphene grown on copper substrates by chemical vapor deposition to polydimethylsiloxane (PDMS) and SiO 2 /Si surfaces. The transfer of graphene was achieved by a simple, etching-free method onto flexible PDMS substrates.

  19. A simple and novel method for retrieval of Pasteurellaceae from swab samples collected in the field

    DEFF Research Database (Denmark)

    Hansen, Mie J; Bertelsen, Mads F; Dietz, Rune

    2013-01-01

    and stored at -20°C. As a control study, 15 samples were collected from the oral cavity of a captive brown bear. One was immediately plated, while the remaining 12 swabs were stored at -20°C for 7 days and multiples of 30 days up to 330 days prior to plating. Two samples were stored without the medium for 7......Traditionally it has been difficult or impossible to collect and preserve bacterial samples of especially fastidious bacteria in mixed primary cultures, unless the samples could be transported to a laboratory within approximately 24 h. Therefore, a simple novel method for preserving swab samples...... until bacterial isolation can be completed in the laboratory was developed and evaluated. Pasteurellaceae bacteria were used as a representative for fastidious bacteria. A 7.5% glucose serum medium was used as freeze medium. Swab samples were soaked in the medium a maximum of 2 h after collection...

  20. Simple analytical technique for liquid scintillation counting of environmental carbon-14 using gel suspension method

    International Nuclear Information System (INIS)

    Okai, Tomio; Wakabayashi, Genichiro; Nagao, Kenjiro; Matoba, Masaru; Ohura, Hirotaka; Momoshima, Noriyuki; Kawamura, Hidehisa

    2000-01-01

    A simple analytical technique for liquid scintillation counting of environmental 14 C was developed. Commercially available gelling agent, N-lauroyl-L -glutamic -α,γ-dibutylamide, was used for the gel-formation of the samples (gel suspension method) and for the subsequent liquid scintillation counting of 14 C in the form of CaCO 3 . Our procedure for sample preparation is much simpler than that of the conventional methods and requires no special equipment. Self absorption, stability and reproducibility of gel suspension samples were investigated in order to evaluate the characteristics of the gel suspension method for 14 C activity measurement. The self absorption factor is about 70% and slightly decrease as CaCO 3 weight increase. This is considered to be mainly due to the absorption of β-rays and scintillation light by the CaCO 3 sample itself. No change of the counting rate for the gel suspension sample was observed for more than 2 years after the sample preparation. Four samples were used for checking the reproducibility of the sample preparation method. The same values were obtained for the counting rate of 24 C activity within the counting error. No change of the counting rate was observed for the 're-gelated' sample. These results show that the gel suspension method is appropriate for the 14 C activity measurement by the liquid scintillation counting method and useful for a long-term preservation of the sample for repeated measurement. The above analytical technique was applied to actual environmental samples in Fukuoka prefecture, Japan. Results obtained were comparable with those by other researchers and appear to be reasonable. Therefore, the newly developed technique is useful for the routine monitoring of environmental 14 C. (author)

  1. A simple method for plasma total vitamin C analysis suitable for routine clinical laboratory use.

    Science.gov (United States)

    Robitaille, Line; Hoffer, L John

    2016-04-21

    In-hospital hypovitaminosis C is highly prevalent but almost completely unrecognized. Medical awareness of this potentially important disorder is hindered by the inability of most hospital laboratories to determine plasma vitamin C concentrations. The availability of a simple, reliable method for analyzing plasma vitamin C could increase opportunities for routine plasma vitamin C analysis in clinical medicine. Plasma vitamin C can be analyzed by high performance liquid chromatography (HPLC) with electrochemical (EC) or ultraviolet (UV) light detection. We modified existing UV-HPLC methods for plasma total vitamin C analysis (the sum of ascorbic and dehydroascorbic acid) to develop a simple, constant-low-pH sample reduction procedure followed by isocratic reverse-phase HPLC separation using a purely aqueous low-pH non-buffered mobile phase. Although EC-HPLC is widely recommended over UV-HPLC for plasma total vitamin C analysis, the two methods have never been directly compared. We formally compared the simplified UV-HPLC method with EC-HPLC in 80 consecutive clinical samples. The simplified UV-HPLC method was less expensive, easier to set up, required fewer reagents and no pH adjustments, and demonstrated greater sample stability than many existing methods for plasma vitamin C analysis. When compared with the gold-standard EC-HPLC method in 80 consecutive clinical samples exhibiting a wide range of plasma vitamin C concentrations, it performed equivalently. The easy set up, simplicity and sensitivity of the plasma vitamin C analysis method described here could make it practical in a normally equipped hospital laboratory. Unlike any prior UV-HPLC method for plasma total vitamin C analysis, it was rigorously compared with the gold-standard EC-HPLC method and performed equivalently. Adoption of this method could increase the availability of plasma vitamin C analysis in clinical medicine.

  2. A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xiaoguang [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Department of Medical Microbiology, Harbin Medical University, Harbin 150086 (China); Center for AIDS Research, Kumamoto University, 2-2-1 Honjo, Kumamoto 860-0811 (Japan); Qian, Hua [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Center for AIDS Research, Kumamoto University, 2-2-1 Honjo, Kumamoto 860-0811 (Japan); Miyamoto, Fusako [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Naito, Takeshi [Laboratory of Virus Control, Institute for Virus Research, Kyoto University, 53 Kawaramachi, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Kawaji, Kumi [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Kajiwara, Kazumi [Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan); JST Innovation Plaza Kyoto, Japan Science and Technology Agency, Nishigyo-ku, Kyoto 615-8245 (Japan); Hattori, Toshio [Tohoku University Graduate School of Medicine, Department of Internal Medicine/Division of Emerging Infectious Diseases, Sendai 980-8575 (Japan); Matsuoka, Masao [Laboratory of Virus Control, Institute for Virus Research, Kyoto University, 53 Kawaramachi, Shogoin, Sakyo-ku, Kyoto 606-8507 (Japan); Watanabe, Kentaro; Oishi, Shinya; Fujii, Nobutaka [Graduate School of Pharmaceutical Sciences, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan); and others

    2012-07-27

    Highlights: Black-Right-Pointing-Pointer We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. Black-Right-Pointing-Pointer The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. Black-Right-Pointing-Pointer In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviral activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1{sub IIIB} and HIV-1{sub BaL} as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1{sub IIIB} activity, whereas fusion inhibitors showed both anti-HIV-1{sub IIIB} and anti-HIV-1{sub BaL} activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, 'phenotypic drug evaluation', may be applicable for the evaluation of various antiviral drugs in vivo.

  3. Development of Test Method for Simple Shear and Prediction of Hardening Behavior Considering the Branchings Effect

    International Nuclear Information System (INIS)

    Kim, Dongwook; Bang, Sungsik; Kim, Minsoo; Lee, Hyungyil; Kim, Naksoo

    2013-01-01

    In this study we establish a process to predict hardening behavior considering the Branchings effect for zircaloy-4 sheets. When a metal is compressed after tension in forming, the yield strength decreases. For this reason, the Branchings effect should be considered in FE simulations of spring-back. We suggested a suitable specimen size and a method for determining the optimum tightening torque for simple shear tests. Shear stress-strain curves are obtained for five materials. We developed a method to convert the shear load-displacement curve to the effective stress-strain curve with Fea. We simulated the simple shear forward/reverse test using the combined isotropic/kinematic hardening model. We also investigated the change of the load-displacement curve by varying the hardening coefficients. We determined the hardening coefficients so that they follow the hardening behavior of zircaloy-4 in experiments

  4. Development of Test Method for Simple Shear and Prediction of Hardening Behavior Considering the Branchings Effect

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dongwook; Bang, Sungsik; Kim, Minsoo; Lee, Hyungyil; Kim, Naksoo [Sogang Univ., Seoul (Korea, Republic of)

    2013-10-15

    In this study we establish a process to predict hardening behavior considering the Branchings effect for zircaloy-4 sheets. When a metal is compressed after tension in forming, the yield strength decreases. For this reason, the Branchings effect should be considered in FE simulations of spring-back. We suggested a suitable specimen size and a method for determining the optimum tightening torque for simple shear tests. Shear stress-strain curves are obtained for five materials. We developed a method to convert the shear load-displacement curve to the effective stress-strain curve with Fea. We simulated the simple shear forward/reverse test using the combined isotropic/kinematic hardening model. We also investigated the change of the load-displacement curve by varying the hardening coefficients. We determined the hardening coefficients so that they follow the hardening behavior of zircaloy-4 in experiments.

  5. Linearized self-consistent quasiparticle GW method: Application to semiconductors and simple metals

    International Nuclear Information System (INIS)

    Kutepov, A. L.

    2017-01-01

    We present a code implementing the linearized self-consistent quasiparticle GW method (QSGW) in the LAPW basis. Our approach is based on the linearization of the self-energy around zero frequency which differs it from the existing implementations of the QSGW method. The linearization allows us to use Matsubara frequencies instead of working on the real axis. This results in efficiency gains by switching to the imaginary time representation in the same way as in the space time method. The all electron LAPW basis set eliminates the need for pseudopotentials. We discuss the advantages of our approach, such as its N 3 scaling with the system size N, as well as its shortcomings. We apply our approach to study the electronic properties of selected semiconductors, insulators, and simple metals and show that our code produces the results very close to the previously published QSGW data. Our implementation is a good platform for further many body diagrammatic resummations such as the vertex-corrected GW approach and the GW+DMFT method.

  6. A simple integrated assessment approach to global change simulation and evaluation

    Science.gov (United States)

    Ogutu, Keroboto; D'Andrea, Fabio; Ghil, Michael

    2016-04-01

    We formulate and study the Coupled Climate-Economy-Biosphere (CoCEB) model, which constitutes the basis of our idealized integrated assessment approach to simulating and evaluating global change. CoCEB is composed of a physical climate module, based on Earth's energy balance, and an economy module that uses endogenous economic growth with physical and human capital accumulation. A biosphere model is likewise under study and will be coupled to the existing two modules. We concentrate on the interactions between the two subsystems: the effect of climate on the economy, via damage functions, and the effect of the economy on climate, via a control of the greenhouse gas emissions. Simple functional forms of the relation between the two subsystems permit simple interpretations of the coupled effects. The CoCEB model is used to make hypotheses on the long-term effect of investment in emission abatement, and on the comparative efficacy of different approaches to abatement, in particular by investing in low carbon technology, in deforestation reduction or in carbon capture and storage (CCS). The CoCEB model is very flexible and transparent, and it allows one to easily formulate and compare different functional representations of climate change mitigation policies. Using different mitigation measures and their cost estimates, as found in the literature, one is able to compare these measures in a coherent way.

  7. An operationally simple method for separating the rare-earth elements neodymium and dysprosium

    Energy Technology Data Exchange (ETDEWEB)

    Bogart, Justin A.; Lippincott, Connor A.; Carroll, Patrick J.; Schelter, Eric J. [Department of Chemistry, University of Pennsylvania, Philadelphia, PA (United States)

    2015-07-06

    Rare-earth metals are critical components of electronic materials and permanent magnets. Recycling of consumer materials is a promising new source of rare earths. To incentivize recycling there is a clear need for simple methods for targeted separations of mixtures of rare-earth metal salts. Metal complexes of a tripodal nitroxide ligand [{(2-"tBuNO)C_6H_4CH_2}{sub 3}N]{sup 3-} (TriNOx{sup 3-}), feature a size-sensitive aperture formed of its three η{sup 2}-(N,O) ligand arms. Exposure of metal cations in the aperture induces a self-associative equilibrium comprising [M(TriNOx)thf]/[M(TriNOx)]{sub 2} (M=rare-earth metal). Differences in the equilibrium constants (K{sub eq}) for early and late metals enables simple Nd/Dy separations through leaching with a separation ratio S{sub Nd/Dy}=359. (copyright 2015 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  8. Simple method for functionalization of silica with alkyl silane and organic ligands

    Directory of Open Access Journals (Sweden)

    Kasim Mohammed Hello

    2018-06-01

    Full Text Available 3–(chloropropyltriethoxysilane (CPTES with imidazole and sodium silicate from rice husk ash (RHA successfully reacted within a short time in one–pot synthesis in purely homogenous method. A similar procedure was used for the immobilization of melamine and saccharine to demonstrate a generally applicable method. No reflux was needed, and a green solvent was used as the reaction medium. The surface areas of the prepared materials were very high compared with the materials which have similar structure prepared by the traditional method. The TGA/DTA confirmed that all the materials were highly stable. The FT-IR shows that all expected the functional groups were present. The HRTEM showed that the materials had ordered mesoporous straight-channels which were like the MCM-41. The synthesis procedure is simple, repeatable with different organic ligands and does not require toxic solvents or multiple steps with high products yield. Keywords: Rice husk ash, MCM-41, Imidazole, Melamine, Saccharine

  9. A simple orbit-attitude coupled modelling method for large solar power satellites

    Science.gov (United States)

    Li, Qingjun; Wang, Bo; Deng, Zichen; Ouyang, Huajiang; Wei, Yi

    2018-04-01

    A simple modelling method is proposed to study the orbit-attitude coupled dynamics of large solar power satellites based on natural coordinate formulation. The generalized coordinates are composed of Cartesian coordinates of two points and Cartesian components of two unitary vectors instead of Euler angles and angular velocities, which is the reason for its simplicity. Firstly, in order to develop natural coordinate formulation to take gravitational force and gravity gradient torque of a rigid body into account, Taylor series expansion is adopted to approximate the gravitational potential energy. The equations of motion are constructed through constrained Hamilton's equations. Then, an energy- and constraint-conserving algorithm is presented to solve the differential-algebraic equations. Finally, the proposed method is applied to simulate the orbit-attitude coupled dynamics and control of a large solar power satellite considering gravity gradient torque and solar radiation pressure. This method is also applicable to dynamic modelling of other rigid multibody aerospace systems.

  10. Evaluation of Oral and Maxillofacial Surgery Residents' Operative Skills: Feasibility and Engagement Study Using SIMPL Software for a Mobile Phone.

    Science.gov (United States)

    Kaban, Leonard B; Cappetta, Alyssa; George, Brian C; Lahey, Edward T; Bohnen, Jordan D; Troulis, Maria J

    2017-10-01

    There are no universally accepted tools to evaluate operative skills of surgical residents in a timely fashion. The purpose of this study was to determine the feasibility of using a smartphone application, SIMPL (System for Improving and Measuring Procedural Learning), developed by a multi-institutional research collaborative, to achieve a high rate of timely operative evaluations and resident communication and to collect performance data. The authors hypothesized that these goals would be achieved because the process is convenient and efficient. This was a prospective feasibility and engagement study using SIMPL to evaluate residents' operative skills. SIMPL requires the attending surgeon to answer 3 multiple-choice questions: 1) What level of help (Zwisch Scale) was required by the trainee? 2) What was the level of performance? 3) How complex was the case? The evaluator also can dictate a narrative. The sample was composed of 3 faculty members and 3 volunteer senior residents. Predictor variables were the surgeons, trainees, and procedures performed. Outcome variables included number and percentage of procedures performed by faculty-and-resident pairs assessed, time required to complete assessments, time lapsed to submission, percentage of assessments with narratives, and residents' response rates. From March through June 2016, 151 procedures were performed in the operating room by the faculty-and-resident teams. There were 107 assessments submitted (71%). Resident response (self-assessment) to faculty evaluations was 81%. Recorded time to complete assessments (n = 75 of 107) was shorter than 2 minutes. The time lapsed to submission was shorter than 72 hours (100%). Dictations were submitted for 35 evaluations (33%). Data for the type of help, performance, and complexity of cases were collected for each resident. SIMPL facilitates timely intraoperative evaluations of surgical skills, engagement by faculty and residents, and collection of detailed procedural

  11. Control of Solar Power Plants Connected Grid with Simple Calculation Method on Residential Homes

    Science.gov (United States)

    Kananda, Kiki; Nazir, Refdinal

    2017-12-01

    One of the most compatible renewable energy in all regions to apply is solar energy. Solar power plants can be built connected to existing or stand-alone power grids. In assisting the residential electricity in which there is a power grid, then a small scale solar energy power plants is very appropriate. However, the general constraint of solar energy power plants is still low in terms of efficiency. Therefore, this study will explain how to control the power of solar power plants more optimally, which is expected to reactive power to zero to raise efficiency. This is a continuation of previous research using Newton Rapshon control method. In this study we introduce a simple method by using ordinary mathematical calculations of solar-related equations. In this model, 10 PV modules type of ND T060M1 with a 60 Wp capacity are used. The calculations performed using MATLAB Simulink provide excellent value. For PCC voltage values obtained a stable quantity of approximately 220 V. At a maximum irradiation condition of 1000 W / m2, the reactive power value of Q solar generating system maximum 20.48 Var and maximum active power of 417.5 W. In the condition of lower irradiation, value of reactive power Q almost close to zero 0.77Var. This simple mathematical method can provide excellent quality control power values.

  12. A Rapid Selection Procedure for Simple Commercial Implementation of omega-Transaminase Reactions

    DEFF Research Database (Denmark)

    Gundersen Deslauriers, Maria; Tufvesson, Pär; Rackham, Emma J.

    2016-01-01

    A stepwise selection procedure is presented to quickly evaluate whether a given omega-transaminase reaction is suitable for a so-called "simple" scale-up for fast industrial implementation. Here "simple" is defined as a system without the need for extensive process development or specialized......, and (3) determination of product inhibition. The method is exemplified with experimental work focused on two products: 1-(4-bromophenyl)ethylamine and (S)-(+)3-amino-1-Boc-piperidine, synthesized from their corresponding pro-chiral ketones each with two alternative amine donors, propan-2-amine, and 1......-phenylethylamine. Each step of the method has a threshold value, which must be surpassed to allow "simple" implementation, helping select suitable combinations of substrates, enzymes, and donors. One reaction pair, 1-Boc-3-piperidone with propan-2-amine, met the criteria of the three-step selection procedure...

  13. A simple and efficient method for assembling TALE protein based on plasmid library.

    Science.gov (United States)

    Zhang, Zhiqiang; Li, Duo; Xu, Huarong; Xin, Ying; Zhang, Tingting; Ma, Lixia; Wang, Xin; Chen, Zhilong; Zhang, Zhiying

    2013-01-01

    DNA binding domain of the transcription activator-like effectors (TALEs) from Xanthomonas sp. consists of tandem repeats that can be rearranged according to a simple cipher to target new DNA sequences with high DNA-binding specificity. This technology has been successfully applied in varieties of species for genome engineering. However, assembling long TALE tandem repeats remains a big challenge precluding wide use of this technology. Although several new methodologies for efficiently assembling TALE repeats have been recently reported, all of them require either sophisticated facilities or skilled technicians to carry them out. Here, we described a simple and efficient method for generating customized TALE nucleases (TALENs) and TALE transcription factors (TALE-TFs) based on TALE repeat tetramer library. A tetramer library consisting of 256 tetramers covers all possible combinations of 4 base pairs. A set of unique primers was designed for amplification of these tetramers. PCR products were assembled by one step of digestion/ligation reaction. 12 TALE constructs including 4 TALEN pairs targeted to mouse Gt(ROSA)26Sor gene and mouse Mstn gene sequences as well as 4 TALE-TF constructs targeted to mouse Oct4, c-Myc, Klf4 and Sox2 gene promoter sequences were generated by using our method. The construction routines took 3 days and parallel constructions were available. The rate of positive clones during colony PCR verification was 64% on average. Sequencing results suggested that all TALE constructs were performed with high successful rate. This is a rapid and cost-efficient method using the most common enzymes and facilities with a high success rate.

  14. A simple and accurate method for bidimensional position read-out of parallel plate avalanche counters

    International Nuclear Information System (INIS)

    Breskin, A.; Zwang, N.

    1977-01-01

    A simple method for bidimensional position read-out of Parallel Plate Avalanche counters (PPAC) has been developed, using the induced charge technique. An accuracy better than 0.5 mm (FWHM) has been achieved for both coordinates with 5.5. MeV α-particles at gas pressures of 10-40 torr. (author)

  15. Simple methods for in vitro pollen germination and pollen preservation of selected species of the genus Agave

    Directory of Open Access Journals (Sweden)

    Sigifredo López Díaz

    2008-01-01

    Full Text Available Simple methods to evaluate the viability and to preserve Agave tequilana Weber var. azul and A. angustifolia Haw pollen were established. Pollen viability was assessed by improving a growing media and evaluating three common pollen germination media components: sucrose, boric acid, and calcium ion. Optimal germination of pollen was obtained at 0.300 M sucrose, 0.324 mM boric acid, and 1.219 mM calcium nitrate and incubated at a temperature of 25°C. Agave pollen was preserved in olive oil and organic solvents. Olive oil, which is immiscible with water, provides an anhydrous environment and limits available oxygen, conditions similar to those provided by some organic solvents. Fresh pollen was put into eppendorf tubes containing n-butanol, n-propanol, isopropanol, extra virgin olive oil and preserved at -20, 4, and 25°C. The germination of the preserved pollen was scored at different time periods during preservation employing the optimal germination medium. The viability of pollen grains preserved at -20°C in olive oil, proved olive oil as an efficient medium for agave pollen preservation for at least 6 months.

  16. A simple method for labelling proteins with 211At via diazotized aromatic diamine

    International Nuclear Information System (INIS)

    Wunderlich, G.; Franke, W.-G.; Fischer, S.; Dreyer, R.

    1987-01-01

    A simple and rapid method for labelling proteins with 211 At by means of a 1,4-diaminobenzene link is described. This link is transformed into the diazonium salt and subsequently reactions of both 211 At and proteins with the diazonium salt take place simultaneously. For possibly high yields of astatized protein an appropriate temperature of 273 K was found. The results demonstrate the difference between the reaction mechanisms of iodine and astatine with proteins. (author)

  17. Method for including detailed evaluation of daylight levels in Be06

    DEFF Research Database (Denmark)

    Petersen, Steffen

    2008-01-01

    Good daylight conditions in office buildings have become an important issue due to new European regulatory demands which include energy consumption for electrical lighting in the building energy frame. Good daylight conditions in offices are thus in increased focus as an energy conserving measure....... In order to evaluate whether a certain design is good daylight design or not building designers must perform detailed evaluation of daylight levels, including the daylight performance of dynamic solar shadings, and include these in the energy performance evaluation. However, the mandatory national...... calculation tool in Denmark (Be06) for evaluating the energy performance of buildings is currently using a simple representation of available daylight in a room and simple assumptions regarding the control of shading devices. In a case example, this is leading to an overestimation of the energy consumption...

  18. Use of simple finite elements for mechanical systems impact analysis based on stereomechanics, stress wave propagation, and energy method approaches

    International Nuclear Information System (INIS)

    McCoy, Michael L.; Moradi, Rasoul; Lankarani, Hamid M.

    2011-01-01

    This paper examines the effectiveness of analyzing impact events in mechanical systems for design purposes using simple or low ordered finite elements. Traditional impact dynamics analyses of mechanical systems namely stereomechanics, energy method, stress-wave propagation and contact mechanics approaches are limited to very simplified geometries and provide basic analyses in making predictions and understanding the dominant features of the impact in a mechanical system. In engineering practice, impacted systems present a complexity of geometry, stiffness, mass distributions, contact areas and impact angles that are impossible to analyze and design with the traditional impact dynamics methods. In real cases, the effective tool is the finite element (FE) method. The high-end FEA codes though may be not available for typical engineer/designer. This paper provides information on whether impact events of mechanical systems can be successfully modeled using simple or low-order finite elements. FEA models using simple elements are benchmarked against theoretical impact problems and published experimental impact results. As a case study, an FE model using simple plastic beam elements is further tested to predict stresses and deflections in an experimental structural impact

  19. SIMPLE METHOD FOR THE EXTRACTION OF PHOTOPIGMENTS AND MYCOSPORINE-LIKE AMINO ACIDS (MAAS) FROM SYMBIODINIUM SPP.

    Science.gov (United States)

    Numerous extraction methods have been developed and used in the quantitation of both photopigments and mycosporine amino acids (MAAs) found in Symbiodinium sp. and zooanthellate metazoans. We have development of a simple, mild extraction procedure using methanol, which when coupl...

  20. A Simple Method to Determine the "R" or "S" Configuration of Molecules with an Axis of Chirality

    Science.gov (United States)

    Wang, Cunde; Wu, Weiming

    2011-01-01

    A simple method for the "R" or "S" designation of molecules with an axis of chirality is described. The method involves projection of the substituents along the chiral axis, utilizes the Cahn-Ingold-Prelog sequence rules in assigning priority to the substituents, is easy to use, and has broad applicability. (Contains 5 figures.)

  1. Simple and reliable procedure for the evaluation of short-term dynamic processes in power systems

    Energy Technology Data Exchange (ETDEWEB)

    Popovic, D P

    1986-10-01

    An efficient approach is presented to the solution of the short-term dynamics model in power systems. It consists of an adequate algebraic treatment of the original system of nonlinear differential equations, using linearization, decomposition and Cauchy's formula. The simple difference equations obtained in this way are incorporated into a model of the electrical network, which is of a low order compared to the ones usually used. Newton's method is applied to the model formed in this way, which leads to a simple and reliable iterative procedure. The characteristics of the procedure developed are demonstrated on examples of transient stability analysis of real power systems. 12 refs.

  2. A simple gel electrophoresis method for separating polyhedral gold nanoparticles

    Science.gov (United States)

    Kim, Suhee; Lee, Hye Jin

    2015-07-01

    In this paper, a simple approach to separate differently shaped and sized polyhedral gold nanoparticles (NPs) within colloidal solutions via gel electrophoresis is described. Gel running parameters for separating efficiently gold NPs including gel composition, added surfactant types and applied voltage were investigated. The plasmonic properties and physical structure of the separated NPs extracted from the gel matrix were then investigated using transmission electron microscopy (TEM) and UV-vis spectrophotometry respectively. Data analysis revealed that gel electrophoresis conditions of a 1.5 % agarose gel with 0.1 % sodium dodecyl sulfate (SDS) surfactant under an applied voltage of 100 V resulted in the selective isolation of ~ 50 nm polyhedral shaped gold nanoparticles. Further efforts are underway to apply the method to purify biomolecule-conjugated polyhedral Au NPs that can be readily used for NP-enhanced biosensing platforms.

  3. A simple method for the prevention of endometrial autolysis in hysterectomy specimens.

    Science.gov (United States)

    Houghton, J P; Roddy, S; Carroll, S; McCluggage, W G

    2004-03-01

    Uteri are among the most common surgical pathology specimens. Assessment of the endometrium is often difficult because of pronounced tissue autolysis. This study describes a simple method to prevent endometrial autolysis and aid in interpretation of the endometrium. Sixty uteri were injected with formalin using a needle and syringe directed alongside a probe, which was inserted through the external cervical os into the endometrial cavity. Injection was performed on the same day as removal of the uterus. As controls, 60 uteri that were not injected with formalin were examined. The degree of endometrial autolysis was assessed on a four point scale (0-3), with a score of 0 representing no or minimal autolysis and a score of 3 representing extensive autolysis, such that histological interpretation of the endometrium was impossible. In the injected group, the number of cases with scores of 0, 1, 2, and 3 was 42, 13, four, and one, respectively. The corresponding values for the control group were 17, 23, eight, and 12, respectively. This was highly significant (p autolysis in uteri injected with formalin. The use of this simple procedure should be encouraged in hysterectomy specimens.

  4. A simple, fast and accurate in-situ method to measure the rate of transport of redox species through membranes for lithium batteries

    Science.gov (United States)

    Meddings, Nina; Owen, John R.; Garcia-Araez, Nuria

    2017-10-01

    Lithium ion conducting membranes are important to protect the lithium metal electrode and act as a barrier to crossover species such as polysulphides in Li-S systems, redox mediators in Li-O2 cells or dissolved cathode species or electrolyte oxidation products in high voltage Li-ion batteries. We present an in-situ method for measuring permeability of membranes to crossover redox species. The method employs a 'Swagelok' cell design equipped with a glassy carbon working electrode, in which redox species are placed initially in the counter electrode compartment only. Permeability through the membrane, which separates working and counter electrodes, is determined using a square wave voltammetry technique that allows the concentration of crossover redox species to be evaluated over time with very high precision. We test the method using a model and well-behaved electrochemical system to demonstrate its sensitivity, reproducibility and reliability relative to alternative approaches. This new method offers advantages in terms of small electrolyte volume, and simple, fast, quantitative and in-situ measurement.

  5. A Simple Method for Assessing Upper-Limb Force-Velocity Profile in Bench Press.

    Science.gov (United States)

    Rahmani, Abderrahmane; Samozino, Pierre; Morin, Jean-Benoit; Morel, Baptiste

    2018-02-01

    To analyze the reliability and validity of a field computation method based on easy-to-measure data to assess the mean force ([Formula: see text]) and velocity ([Formula: see text]) produced during a ballistic bench-press movement and to verify that the force-velocity profile (F-v) obtained with multiple loaded trials is accurately described. Twelve participants performed ballistic bench presses against various lifted mass from 30% to 70% of their body mass. For each trial, [Formula: see text] and [Formula: see text] were determined from an accelerometer (sampling rate 500 Hz; reference method) and a simple computation method based on upper-limb mass, barbell flight height, and push-off distance. These [Formula: see text] and [Formula: see text] data were used to establish the F-v relationship for each individual and method. A strong to almost perfect reliability was observed between the 2 trials (ICC > .90 for [Formula: see text] and .80 for [Formula: see text], CV%  .80, P push-off distance).

  6. Generating Lie Point Symmetry Groups of (2+1)-Dimensional Broer-Kaup Equation via a Simple Direct Method

    International Nuclear Information System (INIS)

    Ma Hongcai

    2005-01-01

    Using the (2+1)-dimensional Broer-Kaup equation as an simple example, a new direct method is developed to find symmetry groups and symmetry algebras and then exact solutions of nonlinear mathematical physical equations.

  7. Short Communication: A Simple Method for Performing Worm-Egg Counts on Sodium Acetate Formaldehyde-Preserved Samples

    Directory of Open Access Journals (Sweden)

    Wayne Melrose

    2012-01-01

    Full Text Available The Kato Katz method is the most common way of performing worm-egg counts on human faecal samples, but it must be done in the field using freshly collected samples. This makes it difficult to use in remote, poorly accessible situations. This paper describes a simple method for egg counts on preserved samples collected in the field and sent to a central location for further processing.

  8. siMS Score: Simple Method for Quantifying Metabolic Syndrome

    OpenAIRE

    Soldatovic, Ivan; Vukovic, Rade; Culafic, Djordje; Gajic, Milan; Dimitrijevic-Sreckovic, Vesna

    2016-01-01

    Objective To evaluate siMS score and siMS risk score, novel continuous metabolic syndrome scores as methods for quantification of metabolic status and risk. Materials and Methods Developed siMS score was calculated using formula: siMS score = 2*Waist/Height + Gly/5.6 + Tg/1.7 + TAsystolic/130?HDL/1.02 or 1.28 (for male or female subjects, respectively). siMS risk score was calculated using formula: siMS risk score = siMS score * age/45 or 50 (for male or female subjects, respectively) * famil...

  9. The concept and method of closed reduction and internal fixation: a new approach for the treatment of simple zygoma fractures.

    Science.gov (United States)

    Uda, Hirokazu; Kamochi, Hideaki; Sugawara, Yasushi; Sarukawa, Syunji; Sunaga, Ataru

    2013-11-01

    The authors have developed a new minimally invasive surgical procedure for simple zygoma fractures, a closed reduction and internal fixation method, that uses a cannulated cortical screw system. From 2007 to 2012, 42 selected patients with simple zygoma fractures without ocular problems or shear at the zygomatic frontal portion were treated with this method. The mean age of the patients was 33 years (range, 13 to 77 years). The authors achieved good repositioning, equivalent to results achieved with conventional procedures in all cases. No notable complication occurred except for minor infection in two cases. Mean operative time was 32 minutes (range, 19 to 58 minutes). Postoperative relapse was found only in the posterior direction (poperative time, less effect on soft tissue, maintenance of bone healing potential, and decreased postoperative pain and swelling. The authors concluded that this method has the potential to become a future surgical procedure for simple zygoma fractures. Therapeutic, IV.

  10. A simple, rapid, and sensitive system for the evaluation of anti-viral drugs in rats

    International Nuclear Information System (INIS)

    Li, Xiaoguang; Qian, Hua; Miyamoto, Fusako; Naito, Takeshi; Kawaji, Kumi; Kajiwara, Kazumi; Hattori, Toshio; Matsuoka, Masao; Watanabe, Kentaro; Oishi, Shinya; Fujii, Nobutaka

    2012-01-01

    Highlights: ► We established a novel, simple and rapid in vivo system for evaluation of anti-HIV-1 drugs with rats. ► The system may be applicable for other antiviral drugs, and/or useful for initial screening in vivo. ► In this system, TRI-1144 displayed the most potent anti-HIV-1 activity in vivo. -- Abstract: The lack of small animal models for the evaluation of anti-human immunodeficiency virus type 1 (HIV-1) agents hampers drug development. Here, we describe the establishment of a simple and rapid evaluation system in a rat model without animal infection facilities. After intraperitoneal administration of test drugs to rats, antiviral activity in the sera was examined by the MAGI assay. Recently developed inhibitors for HIV-1 entry, two CXCR4 antagonists, TF14016 and FC131, and four fusion inhibitors, T-20, T-20EK, SC29EK, and TRI-1144, were evaluated using HIV-1 IIIB and HIV-1 BaL as representative CXCR4- and CCR5-tropic HIV-1 strains, respectively. CXCR4 antagonists were shown to only possess anti-HIV-1 IIIB activity, whereas fusion inhibitors showed both anti-HIV-1 IIIB and anti-HIV-1 BaL activities in rat sera. These results indicate that test drugs were successfully processed into the rat sera and could be detected by the MAGI assay. In this system, TRI-1144 showed the most potent and sustained antiviral activity. Sera from animals not administered drugs showed substantial anti-HIV-1 activity, indicating that relatively high dose or activity of the test drugs might be needed. In conclusion, the novel rat system established here, “phenotypic drug evaluation”, may be applicable for the evaluation of various antiviral drugs in vivo.

  11. Performance of the Tariff Method: validation of a simple additive algorithm for analysis of verbal autopsies

    Directory of Open Access Journals (Sweden)

    Murray Christopher JL

    2011-08-01

    Full Text Available Abstract Background Verbal autopsies provide valuable information for studying mortality patterns in populations that lack reliable vital registration data. Methods for transforming verbal autopsy results into meaningful information for health workers and policymakers, however, are often costly or complicated to use. We present a simple additive algorithm, the Tariff Method (termed Tariff, which can be used for assigning individual cause of death and for determining cause-specific mortality fractions (CSMFs from verbal autopsy data. Methods Tariff calculates a score, or "tariff," for each cause, for each sign/symptom, across a pool of validated verbal autopsy data. The tariffs are summed for a given response pattern in a verbal autopsy, and this sum (score provides the basis for predicting the cause of death in a dataset. We implemented this algorithm and evaluated the method's predictive ability, both in terms of chance-corrected concordance at the individual cause assignment level and in terms of CSMF accuracy at the population level. The analysis was conducted separately for adult, child, and neonatal verbal autopsies across 500 pairs of train-test validation verbal autopsy data. Results Tariff is capable of outperforming physician-certified verbal autopsy in most cases. In terms of chance-corrected concordance, the method achieves 44.5% in adults, 39% in children, and 23.9% in neonates. CSMF accuracy was 0.745 in adults, 0.709 in children, and 0.679 in neonates. Conclusions Verbal autopsies can be an efficient means of obtaining cause of death data, and Tariff provides an intuitive, reliable method for generating individual cause assignment and CSMFs. The method is transparent and flexible and can be readily implemented by users without training in statistics or computer science.

  12. Discount method for programming language evaluation

    DEFF Research Database (Denmark)

    Kurtev, Svetomir; Christensen, Tommy Aagaard; Thomsen, Bent

    2016-01-01

    This paper presents work in progress on developing a Discount Method for Programming Language Evaluation inspired by the Discount Usability Evaluation method (Benyon 2010) and the Instant Data Analysis method (Kjeldskov et al. 2004). The method is intended to bridge the gap between small scale...... internal language design evaluation methods and large scale surveys and quantitative evaluation methods. The method is designed to be applicable even before a compiler or IDE is developed for a new language. To test the method, a usability evaluation experiment was carried out on the Quorum programming...... language (Stefik et al. 2016) using programmers with experience in C and C#. When comparing our results with previous studies of Quorum, most of the data was comparable though not strictly in agreement. However, the discrepancies were mainly related to the programmers pre-existing expectations...

  13. Evaluation of Strain-Life Fatigue Curve Estimation Methods and Their Application to a Direct-Quenched High-Strength Steel

    Science.gov (United States)

    Dabiri, M.; Ghafouri, M.; Rohani Raftar, H. R.; Björk, T.

    2018-03-01

    Methods to estimate the strain-life curve, which were divided into three categories: simple approximations, artificial neural network-based approaches and continuum damage mechanics models, were examined, and their accuracy was assessed in strain-life evaluation of a direct-quenched high-strength steel. All the prediction methods claim to be able to perform low-cycle fatigue analysis using available or easily obtainable material properties, thus eliminating the need for costly and time-consuming fatigue tests. Simple approximations were able to estimate the strain-life curve with satisfactory accuracy using only monotonic properties. The tested neural network-based model, although yielding acceptable results for the material in question, was found to be overly sensitive to the data sets used for training and showed an inconsistency in estimation of the fatigue life and fatigue properties. The studied continuum damage-based model was able to produce a curve detecting early stages of crack initiation. This model requires more experimental data for calibration than approaches using simple approximations. As a result of the different theories underlying the analyzed methods, the different approaches have different strengths and weaknesses. However, it was found that the group of parametric equations categorized as simple approximations are the easiest for practical use, with their applicability having already been verified for a broad range of materials.

  14. [Evaluation of a simple screening tool for ambulant fall prevention].

    Science.gov (United States)

    Knobe, M; Rasche, P; Rentemeister, L; Bliemel, C; Bücking, B; Bollheimer, L C; Pape, H-C

    2018-02-02

    An individual's risk of falling is generally difficult to detect and it is likely to be underestimated. Thus, preventive measures are challenging and they demand sufficient integration and implementation into aftercare and outpatient management. The Aachen Falls Prevention Scale (AFPS) is a quick and easy tool for patient-driven fall risk assessment. Older adults' risk of falling is identified in a suitable manner and they then have the opportunity to independently assess and monitor their risk of falling. The aim of the current study was to evaluate the AFPS as a simple screening tool in geriatric trauma patients via the identification of influencing factors, e.g. objective or subjective fall risk, fear of falling (FOF) and demographic data. In this context, we investigated older adults' willingness to take part in special activities concerning fall prevention. Retrospectively, all patients over 70 years of age who received in-hospital fracture treatment between July 2014 and April 2016 were analyzed at a level I trauma center. After identification of 884 patients, participants completed a short questionnaire (47 questions, yes/no, Likert scale) comprising the AFPS. A history of falls in the past year was considered an indicator of a balance disorder. In addition, ambulant patients were invited to participate between July and August 2016. In total, 201 patients (mean 80.4 years, range 63-97 years) performed a self-assessment based on the AFPS. After steps 1 and 2 of the AFPS had been completed, 95 (47%) participants rated their subjective risk of falling as high (more than 5 points). Of the participants 84 (42%) were objectively classified as "fallers" with significant effects on their AFPS evaluation and rating of their subjective risk of falling. Furthermore, 67% of the participants identified a general practitioner as their main contact person, and 43% of the respondents viewed the AFPS as a beneficial screening tool in fall risk evaluation (8

  15. A simple nodal force distribution method in refined finite element meshes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jai Hak [Chungbuk National University, Chungju (Korea, Republic of); Shin, Kyu In [Gentec Co., Daejeon (Korea, Republic of); Lee, Dong Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2017-05-15

    In finite element analyses, mesh refinement is frequently performed to obtain accurate stress or strain values or to accurately define the geometry. After mesh refinement, equivalent nodal forces should be calculated at the nodes in the refined mesh. If field variables and material properties are available at the integration points in each element, then the accurate equivalent nodal forces can be calculated using an adequate numerical integration. However, in certain circumstances, equivalent nodal forces cannot be calculated because field variable data are not available. In this study, a very simple nodal force distribution method was proposed. Nodal forces of the original finite element mesh are distributed to the nodes of refined meshes to satisfy the equilibrium conditions. The effect of element size should also be considered in determining the magnitude of the distributing nodal forces. A program was developed based on the proposed method, and several example problems were solved to verify the accuracy and effectiveness of the proposed method. From the results, accurate stress field can be recognized to be obtained from refined meshes using the proposed nodal force distribution method. In example problems, the difference between the obtained maximum stress and target stress value was less than 6 % in models with 8-node hexahedral elements and less than 1 % in models with 20-node hexahedral elements or 10-node tetrahedral elements.

  16. Evaluating elastic modulus and strength of hard coatings by relative method

    International Nuclear Information System (INIS)

    Bao, Y.W.; Zhou, Y.C.; Bu, X.X.; Qiu, Y.

    2007-01-01

    A simple approach named relative method is developed for determining the elastic modulus and strength of hard coatings. Analytical relationship among the moduli of the film, the substrate, and the film/substrate system was derived based on bending model, from which the elastic modulus of the coating can be determined uniquely via the measured moduli of the samples before and after coating. Furthermore, the relationship between the strength of the films and the bending strength of the coated sample is derived, thus both the modulus and the strength of coating can be evaluated via traditional tests on coated samples. Mathematic expressions of those calculations were derived, respectively for rectangular beam samples with three types of coating configurations: single face coating, sandwich coating and around coating. Experimental results using various brittle coatings demonstrated the validity and convenience of this method

  17. Evaluating elastic modulus and strength of hard coatings by relative method

    Energy Technology Data Exchange (ETDEWEB)

    Bao, Y.W. [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); China Building Materials Academy, Beijing 100024 (China)], E-mail: ywbao@imr.ac.cn; Zhou, Y.C. [Shenyang National Laboratory for Materials Science, Institute of Metal Research, Chinese Academy of Sciences, 72 Wenhua Road, Shenyang 110016 (China); Bu, X.X. [China Building Materials Academy, Beijing 100024 (China); Qiu, Y. [China Building Materials Academy, Beijing 100024 (China)

    2007-06-15

    A simple approach named relative method is developed for determining the elastic modulus and strength of hard coatings. Analytical relationship among the moduli of the film, the substrate, and the film/substrate system was derived based on bending model, from which the elastic modulus of the coating can be determined uniquely via the measured moduli of the samples before and after coating. Furthermore, the relationship between the strength of the films and the bending strength of the coated sample is derived, thus both the modulus and the strength of coating can be evaluated via traditional tests on coated samples. Mathematic expressions of those calculations were derived, respectively for rectangular beam samples with three types of coating configurations: single face coating, sandwich coating and around coating. Experimental results using various brittle coatings demonstrated the validity and convenience of this method.

  18. Fast and simple method for semiquantitative determination of calcium propionate in bread samples.

    Science.gov (United States)

    Phechkrajang, Chutima Matayatsuk; Yooyong, Surin

    2017-04-01

    Calcium propionate has been widely used as a preservative in bakery and in bread. It is sometimes not carefully used, or a high concentration is added to preserve products. High consumption of calcium propionate can lead to several health problems. This study aims to develop a fast and simple semiquantitative method based on color complex formation for the determination of calcium propionate in a bread sample. A red-brown complex was obtained from the reaction of ferric ammonium sulfate and propionate anion. The product was rapidly formed and easily observed with the concentration of propionate anion >0.4 mg/mL. A high-performance liquid chromatography (HPLC) method was also developed and validated for comparison. Twenty-two bread samples from three markets near Bangkok were randomly selected and assayed for calcium propionate using the above two developed methods. The results showed that 19/22 samples contained calcium propionate >2000 mg/kg. The results of the complex formation method agreed with the HPLC method. Copyright © 2016. Published by Elsevier B.V.

  19. Fast and simple method for semiquantitative determination of calcium propionate in bread samples

    Directory of Open Access Journals (Sweden)

    Chutima Matayatsuk Phechkrajang

    2017-04-01

    Full Text Available Calcium propionate has been widely used as a preservative in bakery and in bread. It is sometimes not carefully used, or a high concentration is added to preserve products. High consumption of calcium propionate can lead to several health problems. This study aims to develop a fast and simple semiquantitative method based on color complex formation for the determination of calcium propionate in a bread sample. A red–brown complex was obtained from the reaction of ferric ammonium sulfate and propionate anion. The product was rapidly formed and easily observed with the concentration of propionate anion >0.4 mg/mL. A high-performance liquid chromatography (HPLC method was also developed and validated for comparison. Twenty-two bread samples from three markets near Bangkok were randomly selected and assayed for calcium propionate using the above two developed methods. The results showed that 19/22 samples contained calcium propionate >2000 mg/kg. The results of the complex formation method agreed with the HPLC method.

  20. A Rapid, Simple, and Validated RP-HPLC Method for Quantitative Analysis of Levofloxacin in Human Plasma

    Directory of Open Access Journals (Sweden)

    Dion Notario

    2017-04-01

    Full Text Available To conduct a bioequivalence study for a copy product of levofloxacin (LEV, a simple and validated analytical method was needed, but the previous developed methods were still too complicated. For this reason, a simple and rapid high performance liquid chromatography method was developed and validated for LEV quantification in human plasma. Chromatographic separation was performed under isocratic elution on a Luna Phenomenex® C18 (150 × 4.6 mm, 5 µm column. The mobile phase was comprised of acetonitrile, methanol, and phosphate buffer 25 mM that adjusted at pH 3.0 (13:7:80 v/v/v and pumped at a flow rate of 1.5 mL/min. Detection was performed under UV detector at wavelength of 280 nm. Samples were prepared by adding acetonitrile and followed by centrifugation to precipitate plasma protein. Then followed successively by evaporation and reconstitution step. The optimized method meets the requirements of validation parameters which included linearity (r = 0.995, sensitivity (LLOQ and LOD was 1.77 and 0.57 µg/mL respectively, accuracy (%error above LLOQ ≤ 12% and LLOQ ≤ 20%, precision (RSD ≤ 9%, and robustness in the ranges of 1.77-28.83 µg/mL. Therefore, the method can be used as a routine analysis of LEV in human plasma as well as in bioequivalence study of LEV.

  1. A method for evaluating horizontal well pumping tests.

    Science.gov (United States)

    Langseth, David E; Smyth, Andrew H; May, James

    2004-01-01

    Predicting the future performance of horizontal wells under varying pumping conditions requires estimates of basic aquifer parameters, notably transmissivity and storativity. For vertical wells, there are well-established methods for estimating these parameters, typically based on either the recovery from induced head changes in a well or from the head response in observation wells to pumping in a test well. Comparable aquifer parameter estimation methods for horizontal wells have not been presented in the ground water literature. Formation parameter estimation methods based on measurements of pressure in horizontal wells have been presented in the petroleum industry literature, but these methods have limited applicability for ground water evaluation and are based on pressure measurements in only the horizontal well borehole, rather than in observation wells. This paper presents a simple and versatile method by which pumping test procedures developed for vertical wells can be applied to horizontal well pumping tests. The method presented here uses the principle of superposition to represent the horizontal well as a series of partially penetrating vertical wells. This concept is used to estimate a distance from an observation well at which a vertical well that has the same total pumping rate as the horizontal well will produce the same drawdown as the horizontal well. This equivalent distance may then be associated with an observation well for use in pumping test algorithms and type curves developed for vertical wells. The method is shown to produce good results for confined aquifers and unconfined aquifers in the absence of delayed yield response. For unconfined aquifers, the presence of delayed yield response increases the method error.

  2. A simple method to fabricate an NIR detector by PbTe nanowires in a large scale

    International Nuclear Information System (INIS)

    Baghchesara, Mohammad Amin; Yousefi, Ramin; Cheraghizade, Mohsen; Jamali-Sheini, Farid; Saáedi, Abdolhossein; Mahmmoudian, M.R.

    2016-01-01

    Highlights: • PbTe nanowires were grown by tellurization of the Pb sheets for the first time. • It was observed a band gap value for the PbTe nanostructures in the NIR region. • NIR detector was fabricated in a large scale using a simple method. • Effect of Te concentration on morphology of PbTe nanostructures was investigated. - Abstract: A simple method was used to fabricate a near-infrared (NIR) detector using PbTe nanostructures. Samples were synthesized by tellurization of lead sheets in a tube furnace. PbTe nanostructures with wires and flakes shapes were grown on the lead sheets that were placed at 300 and 330 °C, respectively, while, PbTe nanoporous were grown at 360 and 390 °C. X-ray diffraction patterns and X-ray photoelectron spectra results indicated that, the PbTe phase was formed in all samples. UV–vis diffuse reflectance spectra measurements showed a band gap for the PbTe nanostructures in the near-infrared region of the electromagnetic spectrum. Actually, the results indicated that, the band gap values of the PbTe nanowires and nanoporous were 1.54 eV and 1.61 eV, respectively. Finally, the PbTe nanostructures were used as a simple photoresponse device under a red light source. The photoresponse results revealed, PbTe nanowires are promising for photoelectrical applications in the NIR region.

  3. A Simple Method of Spectrum Processing for β-ray Measurement without Pretreatment

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Jun Woo; Kim, Hee Reyoung [UNIST, Ulsan (Korea, Republic of)

    2016-10-15

    Radioactivity analysis of β-emitting radionuclide is important because of its dangerousness of overexposure. γ-ray has been measured by conventional detector such as NaI(Tl) or high purity germanium (HPGe) detector. But β-ray is hard to detect by those detectors because of its short range. Therefore, liquid scintillation counter (LSC) has been used to measure the radioactivity of pure beta emitter but there is huge problem of organic waste production, though LSC has high efficiency for detection of low energy β-ray. To solve this problem, characterization of β-ray measurement in a plastic scintillator was carried out in this study. There have been some studies about plastic scintillator to measure the β-rays without liquid scintillation method. Plastic scintillator has benefits for detection of β-ray because it has relative low effective atomic number. β-ray and γ-ray spectra in cylindrical plastic scintillator was analyzed and a method of separation of β-ray spectrum was suggested. A simple method of β-ray spectrum separation was suggested. The method was verified by chi-square method to estimate the difference between calculated and measured spectrum. This method was successfully applied by using disc source. For future works, practical radioactive source will be used to acquire the pulse height spectrum. The method can be used for measurement of pure β emitter without pretreatment if this method is verified for practical purpose.

  4. A simple method for estimating the size of nuclei on fractal surfaces

    Science.gov (United States)

    Zeng, Qiang

    2017-10-01

    Determining the size of nuclei on complex surfaces remains a big challenge in aspects of biological, material and chemical engineering. Here the author reported a simple method to estimate the size of the nuclei in contact with complex (fractal) surfaces. The established approach was based on the assumptions of contact area proportionality for determining nucleation density and the scaling congruence between nuclei and surfaces for identifying contact regimes. It showed three different regimes governing the equations for estimating the nucleation site density. Nuclei in the size large enough could eliminate the effect of fractal structure. Nuclei in the size small enough could lead to the independence of nucleation site density on fractal parameters. Only when nuclei match the fractal scales, the nucleation site density is associated with the fractal parameters and the size of the nuclei in a coupling pattern. The method was validated by the experimental data reported in the literature. The method may provide an effective way to estimate the size of nuclei on fractal surfaces, through which a number of promising applications in relative fields can be envisioned.

  5. ALTERNATIVE METHOD FOR ON SITE EVALUATION OF THERMAL TRANSMITTANCE

    Directory of Open Access Journals (Sweden)

    Aleksandar Janković

    2017-08-01

    Full Text Available Thermal transmittance or U-value is an indicator of the building envelope thermal properties and a key parameter for evaluation of heat losses through the building elements due to heat transmission. It can be determined by calculation based on thermal characteristics of the building element layers. However, this value does not take into account the effects of irregularities and degradation of certain elements of the envelope caused by aging, which may lead to errors in calculation of the heat losses. An effective and simple method for determination of thermal transmittance is in situ measurement, which is governed by the ISO 9869-1:2014 that defines heat flow meter method. This relatively expensive method leaves marks and damages surface of the building element. Furthermore, the final result is not always reliable, in particular when the building element is light or when the weather conditions are not suitable. In order to avoid the above mentioned problems and to estimate the real thermal transmittance value an alternative experimental method, here referred as the natural convection and radiation method, is proposed in this paper. For determination of thermal transmittance, this method requires only temperatures of inside and outside air, as well as the inner wall surface temperature. A detailed statistical analysis, performed by the software package SPSS ver. 20, shows several more advantages of this method comparing to the standard heat flow meter one, besides economic and non-destructive benefits.

  6. Simple methods for the 3' biotinylation of RNA.

    Science.gov (United States)

    Moritz, Bodo; Wahle, Elmar

    2014-03-01

    Biotinylation of RNA allows its tight coupling to streptavidin and is thus useful for many types of experiments, e.g., pull-downs. Here we describe three simple techniques for biotinylating the 3' ends of RNA molecules generated by chemical or enzymatic synthesis. First, extension with either the Schizosaccharomyces pombe noncanonical poly(A) polymerase Cid1 or Escherichia coli poly(A) polymerase and N6-biotin-ATP is simple, efficient, and generally applicable independently of the 3'-end sequences of the RNA molecule to be labeled. However, depending on the enzyme and the reaction conditions, several or many biotinylated nucleotides are incorporated. Second, conditions are reported under which splint-dependent ligation by T4 DNA ligase can be used to join biotinylated and, presumably, other chemically modified DNA oligonucleotides to RNA 3' ends even if these are heterogeneous as is typical for products of enzymatic synthesis. Third, we describe the use of 29 DNA polymerase for a template-directed fill-in reaction that uses biotin-dUTP and, thanks to the enzyme's proofreading activity, can cope with more extended 3' heterogeneities.

  7. Necessity of Antibiotics following Simple Exodontia

    Directory of Open Access Journals (Sweden)

    Waqas Yousuf

    2016-01-01

    Full Text Available Introduction. The aim of our study is to assess the need for postoperative antibiotics following simple exodontia and determine its role in minimizing patient discomfort and postoperative complications. Material and Methods. All the patients undergoing simple extractions were grouped into two categories: Group 1, patients receiving antibiotics, and Group 2, patients receiving no antibiotics. Patients were recalled on the sixth day to assess postoperative complications. On recall, patients were evaluated for signs of persistent inflammation and signs of dry socket. Presence of persistent inflammation and/or suppuration on the 6th day was considered as wound infection. Results. A total of 146 patients were included in this study. Out of the total sample, 134 (91.8% presented with no postoperative complications and 12 (8.2% had postoperative complications, out of which 11 (7.5% patients presented with dry socket (alveolar osteitis, 5 (3.4% in the antibiotic group and 6 (4.1% in the nonantibiotic group. Only 1 patient (0.7% was reported with infection of the extraction socket in the nonantibiotic group, whereas no case of infection was found in the antibiotic group. Conclusion. Antibiotics are not required after simple extractions in patients who are not medically comprised nor do they have any role in preventing postoperative complications.

  8. Deployment Analysis of a Simple Tape-Spring Hinge Using Probabilistic Methods

    Science.gov (United States)

    Lyle, Karen H.; Horta, Lucas G.

    2012-01-01

    Acceptance of new deployable structures architectures and concepts requires validated design methods to minimize the expense involved with technology validation flight testing. Deployable concepts for large lightweight spacecraft include booms, antennae, and masts. This paper explores the implementation of probabilistic methods in the design process for the deployment of a strain-energy mechanism, specifically a simple tape-spring hinge. Strain-energy mechanisms are attractive for deployment in very lightweight systems because they do not require the added mass and complexity associated with motors and controllers. However, designers are hesitant to include free deployment, strain-energy mechanisms because of the potential for uncontrolled behavior. In the example presented here, the tapespring cross-sectional dimensions have been varied and a target displacement during deployment has been selected as the design metric. Specifically, the tape-spring should reach the final position in the shortest time with the minimal amount of overshoot and oscillations. Surrogate models have been used to reduce computational expense. Parameter values to achieve the target response have been computed and used to demonstrate the approach. Based on these results, the application of probabilistic methods for design of a tape-spring hinge has shown promise as a means of designing strain-energy components for more complex space concepts.

  9. A Simple PCR Method for Rapid Genotype Analysis of Mycobacterium ulcerans

    Science.gov (United States)

    Stinear, Timothy; Davies, John K.; Jenkin, Grant A.; Portaels, Françoise; Ross, Bruce C.; OppEdIsano, Frances; Purcell, Maria; Hayman, John A.; Johnson, Paul D. R.

    2000-01-01

    Two high-copy-number insertion sequences, IS2404 and IS2606, were recently identified in Mycobacterium ulcerans and were shown by Southern hybridization to possess restriction fragment length polymorphism between strains from different geographic origins. We have designed a simple genotyping method that captures these differences by PCR amplification of the region between adjacent copies of IS2404 and IS2606. We have called this system 2426 PCR. The method is rapid, reproducible, sensitive, and specific for M. ulcerans, and it has confirmed previous studies suggesting a clonal population structure of M. ulcerans within a geographic region. M. ulcerans isolates from Australia, Papua New Guinea, Malaysia, Surinam, Mexico, Japan, China, and several countries in Africa were easily differentiated based on an array of 4 to 14 PCR products ranging in size from 200 to 900 bp. Numerical analysis of the banding patterns suggested a close evolutionary link between M. ulcerans isolates from Africa and southeast Asia. The application of 2426 PCR to total DNA, extracted directly from M. ulcerans-infected tissue specimens without culture, demonstrated the sensitivity and specificity of this method and confirmed for the first time that both animal and human isolates from areas of endemicity in southeast Australia have the same genotype. PMID:10747130

  10. A simplified method for evaluating thermal performance of unglazed transpired solar collectors under steady state

    International Nuclear Information System (INIS)

    Wang, Xiaoliang; Lei, Bo; Bi, Haiquan; Yu, Tao

    2017-01-01

    Highlights: • A simplified method for evaluating thermal performance of UTC is developed. • Experiments, numerical simulations, dimensional analysis and data fitting are used. • The correlation of absorber plate temperature for UTC is established. • The empirical correlation of heat exchange effectiveness for UTC is proposed. - Abstract: Due to the advantages of low investment and high energy efficiency, unglazed transpired solar collectors (UTC) have been widely used for heating in buildings. However, it is difficult for designers to quickly evaluate the thermal performance of UTC based on the conventional methods such as experiments and numerical simulations. Therefore, a simple and fast method to determine the thermal performance of UTC is indispensable. The objective of this work is to provide a simplified calculation method to easily evaluate the thermal performance of UTC under steady state. Different parameters are considered in the simplified method, including pitch, perforation diameter, solar radiation, solar absorptivity, approach velocity, ambient air temperature, absorber plate temperature, and so on. Based on existing design parameters and operating conditions, correlations for the absorber plate temperature and the heat exchange effectiveness are developed using dimensional analysis and data fitting, respectively. Results show that the proposed simplified method has a high accuracy and can be employed to evaluate the collector efficiency, the heat exchange effectiveness and the air temperature rise. The proposed method in this paper is beneficial to directly determine design parameters and operating status for UTC.

  11. A simple linear regression method for quantitative trait loci linkage analysis with censored observations.

    Science.gov (United States)

    Anderson, Carl A; McRae, Allan F; Visscher, Peter M

    2006-07-01

    Standard quantitative trait loci (QTL) mapping techniques commonly assume that the trait is both fully observed and normally distributed. When considering survival or age-at-onset traits these assumptions are often incorrect. Methods have been developed to map QTL for survival traits; however, they are both computationally intensive and not available in standard genome analysis software packages. We propose a grouped linear regression method for the analysis of continuous survival data. Using simulation we compare this method to both the Cox and Weibull proportional hazards models and a standard linear regression method that ignores censoring. The grouped linear regression method is of equivalent power to both the Cox and Weibull proportional hazards methods and is significantly better than the standard linear regression method when censored observations are present. The method is also robust to the proportion of censored individuals and the underlying distribution of the trait. On the basis of linear regression methodology, the grouped linear regression model is computationally simple and fast and can be implemented readily in freely available statistical software.

  12. A fast and simple GC MS method for lignan profiling in Anthriscus sylvestris and biosynthetically related plant species

    NARCIS (Netherlands)

    Koulman, A; Bos, R; Medarde, M; Pras, N; Quax, WJ

    2001-01-01

    A new GC-MS method for monitoring lignans was developed to study the variation in plants and elucidate the biosynthetic steps. A simple and fast extraction procedure for lyophilised plant material was developed, giving a lignan-rich extract. A GC-MS method was set up using an apolar WCOT fused

  13. Simple method based on intensity measurements for characterization of aberrations from micro-optical components.

    Science.gov (United States)

    Perrin, Stephane; Baranski, Maciej; Froehly, Luc; Albero, Jorge; Passilly, Nicolas; Gorecki, Christophe

    2015-11-01

    We report a simple method, based on intensity measurements, for the characterization of the wavefront and aberrations produced by micro-optical focusing elements. This method employs the setup presented earlier in [Opt. Express 22, 13202 (2014)] for measurements of the 3D point spread function, on which a basic phase-retrieval algorithm is applied. This combination allows for retrieval of the wavefront generated by the micro-optical element and, in addition, quantification of the optical aberrations through the wavefront decomposition with Zernike polynomials. The optical setup requires only an in-motion imaging system. The technique, adapted for the optimization of micro-optical component fabrication, is demonstrated by characterizing a planoconvex microlens.

  14. Pragmatism, Evidence, and Mixed Methods Evaluation

    Science.gov (United States)

    Hall, Jori N.

    2013-01-01

    Mixed methods evaluation has a long-standing history of enhancing the credibility of evaluation findings. However, using mixed methods in a utilitarian way implicitly emphasizes convenience over engaging with its philosophical underpinnings (Denscombe, 2008). Because of this, some mixed methods evaluators and social science researchers have been…

  15. Stochastic Order Redshift Technique (SORT): a simple, efficient and robust method to improve cosmological redshift measurements

    Science.gov (United States)

    Tejos, Nicolas; Rodríguez-Puebla, Aldo; Primack, Joel R.

    2018-01-01

    We present a simple, efficient and robust approach to improve cosmological redshift measurements. The method is based on the presence of a reference sample for which a precise redshift number distribution (dN/dz) can be obtained for different pencil-beam-like sub-volumes within the original survey. For each sub-volume we then impose that: (i) the redshift number distribution of the uncertain redshift measurements matches the reference dN/dz corrected by their selection functions and (ii) the rank order in redshift of the original ensemble of uncertain measurements is preserved. The latter step is motivated by the fact that random variables drawn from Gaussian probability density functions (PDFs) of different means and arbitrarily large standard deviations satisfy stochastic ordering. We then repeat this simple algorithm for multiple arbitrary pencil-beam-like overlapping sub-volumes; in this manner, each uncertain measurement has multiple (non-independent) 'recovered' redshifts which can be used to estimate a new redshift PDF. We refer to this method as the Stochastic Order Redshift Technique (SORT). We have used a state-of-the-art N-body simulation to test the performance of SORT under simple assumptions and found that it can improve the quality of cosmological redshifts in a robust and efficient manner. Particularly, SORT redshifts (zsort) are able to recover the distinctive features of the so-called 'cosmic web' and can provide unbiased measurement of the two-point correlation function on scales ≳4 h-1Mpc. Given its simplicity, we envision that a method like SORT can be incorporated into more sophisticated algorithms aimed to exploit the full potential of large extragalactic photometric surveys.

  16. A simple and sensitive method for the determination of fibric acids in the liver by liquid chromatography.

    Science.gov (United States)

    Karahashi, Minako; Fukuhara, Hiroto; Hoshina, Miki; Sakamoto, Takeshi; Yamazaki, Tohru; Mitsumoto, Atsushi; Kawashima, Yoichi; Kudo, Naomi

    2014-01-01

    Fibrates are used in biochemical and pharmacological studies as bioactive tools. Nevertheless, most studies have lacked information concerning the concentrations of fibric acids working inside tissues because a simple and sensitive method is not available for their quantitation. This study aimed to develop a simple and sensitive bioanalytical method for the quantitation of clofibric, bezafibric and fenofibric acids in samples of very small portions of tissues. Fibric acids were extracted into n-hexane-ethyl acetate from tissue homogenates (10 mg of liver, kidney or muscle) or serum (100 µL) and were derivatized with 4-bromomethyl-6,7-dimethoxycoumarin, followed by HPLC with fluorescence detection. These compounds were separated isocratically on a reversed phase with acetonitrile-water. Standard analytical curves were linear over the concentration range of 0.2-20 nmol/10 mg of liver. Precision and accuracy were within acceptable limits. Recovery from liver homogenates ranged from 93.03 to 112.29%. This method enabled the quantitation of fibric acids in 10 mg of liver from rats treated with clofibric acid, bezafibric acid or fenofibrate. From these analytical data, it became clear that there was no large difference in ratio of acyl-CoA oxidase 1 (Acox1) mRNA level to fibric acid content in the liver among the three fibric acids, suggesting that these three fibric acids have similar potency to increase expression of the Acox1 gene, which is a target of peroxisome proliferator-activated receptor α. Thus, the proposed method is a simple, sensitive and reliable tool for the quantitation of fibric acids working in vivo inside livers.

  17. Simple and efficient method for region of interest value extraction from picture archiving and communication system viewer with optical character recognition software and macro program.

    Science.gov (United States)

    Lee, Young Han; Park, Eun Hae; Suh, Jin-Suck

    2015-01-01

    The objectives are: 1) to introduce a simple and efficient method for extracting region of interest (ROI) values from a Picture Archiving and Communication System (PACS) viewer using optical character recognition (OCR) software and a macro program, and 2) to evaluate the accuracy of this method with a PACS workstation. This module was designed to extract the ROI values on the images of the PACS, and created as a development tool by using open-source OCR software and an open-source macro program. The principal processes are as follows: (1) capture a region of the ROI values as a graphic file for OCR, (2) recognize the text from the captured image by OCR software, (3) perform error-correction, (4) extract the values including area, average, standard deviation, max, and min values from the text, (5) reformat the values into temporary strings with tabs, and (6) paste the temporary strings into the spreadsheet. This principal process was repeated for the number of ROIs. The accuracy of this module was evaluated on 1040 recognitions from 280 randomly selected ROIs of the magnetic resonance images. The input times of ROIs were compared between conventional manual method and this extraction module-assisted input method. The module for extracting ROI values operated successfully using the OCR and macro programs. The values of the area, average, standard deviation, maximum, and minimum could be recognized and error-corrected with AutoHotkey-coded module. The average input times using the conventional method and the proposed module-assisted method were 34.97 seconds and 7.87 seconds, respectively. A simple and efficient method for ROI value extraction was developed with open-source OCR and a macro program. Accurate inputs of various numbers from ROIs can be extracted with this module. The proposed module could be applied to the next generation of PACS or existing PACS that have not yet been upgraded. Copyright © 2015 AUR. Published by Elsevier Inc. All rights reserved.

  18. Proposal of a method for evaluating tsunami risk using response-surface methodology

    Science.gov (United States)

    Fukutani, Y.

    2017-12-01

    Information on probabilistic tsunami inundation hazards is needed to define and evaluate tsunami risk. Several methods for calculating these hazards have been proposed (e.g. Løvholt et al. (2012), Thio (2012), Fukutani et al. (2014), Goda et al. (2015)). However, these methods are inefficient, and their calculation cost is high, since they require multiple tsunami numerical simulations, therefore lacking versatility. In this study, we proposed a simpler method for tsunami risk evaluation using response-surface methodology. Kotani et al. (2016) proposed an evaluation method for the probabilistic distribution of tsunami wave-height using a response-surface methodology. We expanded their study and developed a probabilistic distribution of tsunami inundation depth. We set the depth (x1) and the slip (x2) of an earthquake fault as explanatory variables and tsunami inundation depth (y) as an object variable. Subsequently, tsunami risk could be evaluated by conducting a Monte Carlo simulation, assuming that the generation probability of an earthquake follows a Poisson distribution, the probability distribution of tsunami inundation depth follows the distribution derived from a response-surface, and the damage probability of a target follows a log normal distribution. We applied the proposed method to a wood building located on the coast of Tokyo Bay. We implemented a regression analysis based on the results of 25 tsunami numerical calculations and developed a response-surface, which was defined as y=ax1+bx2+c (a:0.2615, b:3.1763, c=-1.1802). We assumed proper probabilistic distribution for earthquake generation, inundation height, and vulnerability. Based on these probabilistic distributions, we conducted Monte Carlo simulations of 1,000,000 years. We clarified that the expected damage probability of the studied wood building is 22.5%, assuming that an earthquake occurs. The proposed method is therefore a useful and simple way to evaluate tsunami risk using a response

  19. Simple extraction methods that prevent the artifactual conversion of chlorophyll to chlorophyllide during pigment isolation from leaf samples.

    Science.gov (United States)

    Hu, Xueyun; Tanaka, Ayumi; Tanaka, Ryouichi

    2013-06-19

    When conducting plant research, the measurement of photosynthetic pigments can provide basic information on the physiological status of a plant. High-pressure liquid chromatography (HPLC) is becoming widely used for this purpose because it provides an accurate determination of a variety of photosynthetic pigments simultaneously. This technique has a drawback compared with conventional spectroscopic techniques, however, in that it is more prone to structural modification of pigments during extraction, thus potentially generating erroneous results. During pigment extraction procedures with acetone or alcohol, the phytol side chain of chlorophyll is sometimes removed, forming chlorophyllide, which affects chlorophyll measurement using HPLC. We evaluated the artifactual chlorophyllide production during chlorophyll extraction by comparing different extraction methods with wild-type and mutant Arabidopsis leaves that lack the major isoform of chlorophyllase. Several extraction methods were compared to provide alternatives to researchers who utilize HPLC for the analysis of chlorophyll levels. As a result, the following three methods are recommended. In the first method, leaves are briefly boiled prior to extraction. In the second method, grinding and homogenization of leaves are performed at sub-zero temperatures. In the third method, N, N'-dimethylformamide (DMF) is used for the extraction of pigments. When compared, the first two methods eliminated almost all chlorophyllide-forming activity in Arabidopsis thaliana, Glebionis coronaria, Pisum sativum L. and Prunus sargentii Rehd. However, DMF effectively suppressed the activity of chlorophyllase only in Arabidopsis leaves. Chlorophyllide production in leaf extracts is predominantly an artifact. All three methods evaluated in this study reduce the artifactual production of chlorophyllide and are thus suitable for pigment extraction for HPLC analysis. The boiling method would be a practical choice when leaves are not too

  20. Simple and efficient method for isolation and cultivation of endoscopically obtained human colonocytes

    DEFF Research Database (Denmark)

    Seidelin, Jakob B; Horn, Thomas; Nielsen, Ole H

    2003-01-01

    and where the diagnosis of irritable bowel syndrome was later reached, were included. Seven colon biopsies were taken and incubated at varying time periods of 10-120 min and temperatures of 4-37 degrees C in a chelating buffer. The epithelium was then harvested and cultivated under three different......Few comparative and validated reports exist on the isolation and growth of colonoscopically obtained colonic epithelium. The aim of this study was to develop and validate a simple method for the cultivation of colonoscopically obtained colonocytes. Forty patients, who underwent routine colonoscopy...

  1. Pressure loss coefficient evaluation based on CFD analysis for simple geometries and PWR reactor vessel without geometry simplification

    International Nuclear Information System (INIS)

    Ko II, B.; Park, J. P.; Jeong, J. H.

    2008-01-01

    Nuclear vendors and utilities perform lots of simulations and analyses in order to ensure the safe operation of nuclear power plants (NPPs). In general, the simulations are carried out using vendor-specific design codes and best-estimate system analysis codes and most of them were developed based on 1-dimensional lumped parameter models. These thermal-hydraulic system analysis codes require user input for pressure loss coefficient, k-factor; since they numerically solve Euler-equation. In spite of its high impact on the safety analysis results, there has not been good validation method for the selection of loss coefficient. During the past decade, however; computers, parallel computation methods, and 3-dimensional computational fluid dynamics (CFD) codes have been dramatically enhanced. It is believed to be beneficial to take advantage of advanced commercial CFD codes in safety analysis and design of NPP5. The present work aims to validate pressure loss coefficient evaluation for simple geometries and k-factor calculation for PWR based on CFD. The performances of standard k-ε model, RNG k-ε model, Reynolds stress model (RSM) on the simulation of pressure drop for simple geometry such as, or sudden-expansion, and sudden-contraction are evaluated. The calculated value was compared with pressure loss coefficient in handbook of hydraulic resistance. Then the present work carried out analysis for flow distribution in downcomer and lower plenum of Korean standard nuclear power plants (KSNPs) using STAR-CD. The lower plenum geometry of a PWR is very complicated since there are so many reactor internals, which hinders in CFD analysis for real reactor geometry up to now. The present work takes advantage of 3D CAD model so that real geometry of lower plenum is used. The results give a clear figure about flow fields in the reactor vessel, which is one of major safety concerns. The calculated pressure drop across downcomer and lower plenum appears to be in good agreement

  2. SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

    International Nuclear Information System (INIS)

    Maneru, F; Gracia, M; Gallardo, N; Olasolo, J; Fuentemilla, N; Bragado, L; Martin-Albina, M; Lozares, S; Pellejero, S; Miquelez, S; Rubio, A; Otal, A

    2015-01-01

    Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with 90 Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than other

  3. SU-E-T-02: 90Y Microspheres Dosimetry Calculation with Voxel-S-Value Method: A Simple Use in the Clinic

    Energy Technology Data Exchange (ETDEWEB)

    Maneru, F; Gracia, M; Gallardo, N; Olasolo, J; Fuentemilla, N; Bragado, L; Martin-Albina, M; Lozares, S; Pellejero, S; Miquelez, S; Rubio, A [Complejo Hospitalario de Navarra, Pamplona, Navarra (Spain); Otal, A [Hospital Clinica Benidorm, Benidorm, Alicante (Spain)

    2015-06-15

    Purpose: To present a simple and feasible method of voxel-S-value (VSV) dosimetry calculation for daily clinical use in radioembolization (RE) with {sup 90}Y microspheres. Dose distributions are obtained and visualized over CT images. Methods: Spatial dose distributions and dose in liver and tumor are calculated for RE patients treated with Sirtex Medical miscrospheres at our center. Data obtained from the previous simulation of treatment were the basis for calculations: Tc-99m maggregated albumin SPECT-CT study in a gammacamera (Infinia, General Electric Healthcare.). Attenuation correction and ordered-subsets expectation maximization (OSEM) algorithm were applied.For VSV calculations, both SPECT and CT were exported from the gammacamera workstation and registered with the radiotherapy treatment planning system (Eclipse, Varian Medical systems). Convolution of activity matrix and local dose deposition kernel (S values) was implemented with an in-house developed software based on Python code. The kernel was downloaded from www.medphys.it. Final dose distribution was evaluated with the free software Dicompyler. Results: Liver mean dose is consistent with Partition method calculations (accepted as a good standard). Tumor dose has not been evaluated due to the high dependence on its contouring. Small lesion size, hot spots in health tissue and blurred limits can affect a lot the dose distribution in tumors. Extra work includes: export and import of images and other dicom files, create and calculate a dummy plan of external radiotherapy, convolution calculation and evaluation of the dose distribution with dicompyler. Total time spent is less than 2 hours. Conclusion: VSV calculations do not require any extra appointment or any uncomfortable process for patient. The total process is short enough to carry it out the same day of simulation and to contribute to prescription decisions prior to treatment. Three-dimensional dose knowledge provides much more information than

  4. A Simple and Effective Isocratic HPLC Method for Fast Identification and Quantification of Surfactin

    International Nuclear Information System (INIS)

    Muhammad Qadri Effendy Mubarak; Abdul Rahman Hassan; Aidil Abdul Hamid; Sahaid Khalil; Mohd Hafez Mohd Isa

    2015-01-01

    The aim of this study was to establish a simple, accurate and reproducible method for the identification and quantification of surfactin using high-performance liquid chromatography (HPLC). Previously reported method of identification and quantification of surfactin were time consuming and requires a large quantity of mobile phase. The new method was achieved by application of Chromolith® high performance RP-18 (100 x 4.6 mm, 5 μm) as the stationary phase and optimization of mobile phase ratio and flow rate. Mobile phase consisted of acetonitrile (ACN) and 3.8 mM trifluroacetic acid (TFA) solution of 80:20 ratio at flow rate of 2.2 mL/ min was obtained as the optimal conditions. Total elution time of the obtained surfactin peaks was four times quicker than various methods previously reported in the literature. The method described here allowed for fine separation of surfactin in standard sample (98 % purity) and surfactin in fermentation broth. (author)

  5. A simple method of genomic DNA extraction suitable for analysis of bulk fungal strains.

    Science.gov (United States)

    Zhang, Y J; Zhang, S; Liu, X Z; Wen, H A; Wang, M

    2010-07-01

    A simple and rapid method (designated thermolysis) for extracting genomic DNA from bulk fungal strains was described. In the thermolysis method, a few mycelia or yeast cells were first rinsed with pure water to remove potential PCR inhibitors and then incubated in a lysis buffer at 85 degrees C to break down cell walls and membranes. This method was used to extract genomic DNA from large numbers of fungal strains (more than 92 species, 35 genera of three phyla) isolated from different sections of natural Ophiocordyceps sinensis specimens. Regions of interest from high as well as single-copy number genes were successfully amplified from the extracted DNA samples. The DNA samples obtained by this method can be stored at -20 degrees C for over 1 year. The method was effective, easy and fast and allowed batch DNA extraction from multiple fungal isolates. Use of the thermolysis method will allow researchers to obtain DNA from fungi quickly for use in molecular assays. This method requires only minute quantities of starting material and is suitable for diverse fungal species.

  6. First-Pass Angiography in Mice Using FDG-PET: A Simple Method of Deriving the Cardiovascular Transit Time Without the Need of Region-of-Interest Drawing.

    Science.gov (United States)

    Wu, Hsiao-Ming; Kreissl, Michael C; Schelbert, Heinrich R; Ladno, Waldemar; Prins, Mayumi; Shoghi-Jadid, Kooresh; Chatziioannou, Arion; Phelps, Michael E; Huang, Sung-Cheng

    2005-10-01

    In this study, we developed a simple and robust semi-automatic method to measure the right ventricle to left ventricle (RV-to-LV) transit time (TT) in mice using 2-[ 18 F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET). The accuracy of the method was first evaluated using a 4-D digital dynamic mouse phantom. The RV-to-LV TTs of twenty-nine mouse studies were measured using the new method and compared to those obtained from the conventional ROI-drawing method. The results showed that the new method correctly separated different structures (e.g., RV, lung, and LV) in the PET images and generated corresponding time activity curve (TAC) of each structure. The RV-to-LV TTs obtained from the new method and ROI method were not statistically different (P = 0.20; r = 0.76). We expect that this fast and robust method is applicable to the pathophysiology of cardiovascular diseases using small animal models such as rats and mice.

  7. A simple and efficient method to enhance audiovisual binding tendencies

    Directory of Open Access Journals (Sweden)

    Brian Odegaard

    2017-04-01

    Full Text Available Individuals vary in their tendency to bind signals from multiple senses. For the same set of sights and sounds, one individual may frequently integrate multisensory signals and experience a unified percept, whereas another individual may rarely bind them and often experience two distinct sensations. Thus, while this binding/integration tendency is specific to each individual, it is not clear how plastic this tendency is in adulthood, and how sensory experiences may cause it to change. Here, we conducted an exploratory investigation which provides evidence that (1 the brain’s tendency to bind in spatial perception is plastic, (2 that it can change following brief exposure to simple audiovisual stimuli, and (3 that exposure to temporally synchronous, spatially discrepant stimuli provides the most effective method to modify it. These results can inform current theories about how the brain updates its internal model of the surrounding sensory world, as well as future investigations seeking to increase integration tendencies.

  8. Unconfined twist : a simple method to prepare ultrafine grained metallic materials.

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Y. (Yonghao); Liao, Xiaozhou; Zhu, Y. T. (Yuntian Theodore)

    2004-01-01

    A new simple method - unconfined twist was employed to prepare ultrafine grained (UFG) Fe,wire. A coarse grained (CG) Fe wire with a diameter of 0.85 mm was fixed at one end, and twisted at the other end. After maximum twist before fracture, in the cross-sectional plane, concentrically deformed layers with a width of several micrometers formed surrounding the center axis of the wire. The near-surface deformed layers consist of lamella grains with a width in submicrometer range. In the longitudinal plane, deformed bands (with a width of several micrometers) formed uniformly, which were composed of lamella crystallites (with a width in submicrometer range). The tensile yield strength and ultimate strength of the twisted Fe wire are increased by about 150% and 100% compared with the values of its CG counterpart.

  9. Simulation Opportunity Index, A Simple and Effective Method to Boost the Hydrocarbon Recovery

    KAUST Repository

    Saputra, Wardana

    2016-09-08

    During periods of low oil prices, profitability of field developments drops drastically. To help with this difficulty, a cost-effective method has been proposed to boost the hydrocarbon recovery by optimizing well locations through the Simulated Opportunity Index (SOI). SOI is an intelligent method to identify zones with high potential for production which is empirically calculated from basic rock and fluid properties, and from reservoir pressure as its energy capacity. In order to obtain the best results, the original SOI formula (Molina et al., 2009) was extended to both oil and gas fields. Based on this modified SOI formula, a software program has been developed to locate the best well locations considering multilayer, existing wells, and fault existences. This paper describes how the SOI software helps as a simple, fast, and accurate way to obtain the higher hydrocarbon production than that of trial-error method and previous studies in two different fields located in offshore Indonesia. On one hand, the proposed method could save money by minimizing the required number of wells. On the other hand, it could maximize profit by maximizing recovery.

  10. A simple method to back-project isocenter dose of radiotherapy treatments using EPID transit dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Silveira, T.B.; Cerbaro, B.Q.; Rosa, L.A.R. da, E-mail: thiago.fisimed@gmail.com, E-mail: tbsilveira@inca.gov.br [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro - RJ (Brazil)

    2017-07-01

    The aim of this work was to implement a simple algorithm to evaluate isocenter dose in a phantom using the back-projected transmitted dose acquired using an Electronic Portal Imaging Device (EPID) available in a Varian Trilogy accelerator with two nominal 6 and 10 MV photon beams. This algorithm was developed in MATLAB language, to calibrate EPID measured dose in absolute dose, using a deconvolution process, and to incorporate all scattering and attenuation contributions due to photon interactions with phantom. Modeling process was simplified by using empirical curve adjustments to describe the contribution of scattering and attenuation effects. The implemented algorithm and method were validated employing 19 patient treatment plans with 104 clinical irradiation fields projected on the phantom used. Results for EPID absolute dose calibration by deconvolution have showed percent deviations lower than 1%. Final method validation presented average percent deviations between isocenter doses calculated by back-projection and isocenter doses determined with ionization chamber of 1,86% (SD of 1,00%) and -0,94% (SD of 0,61%) for 6 and 10 MV, respectively. Normalized field by field analysis showed deviations smaller than 2% for 89% of all data for 6 MV beams and 94% for 10 MV beams. It was concluded that the proposed algorithm possesses sufficient accuracy to be used for in vivo dosimetry, being sensitive to detect dose delivery errors bigger than 3-4% for conformal and intensity modulated radiation therapy techniques. (author)

  11. [Simple and useful evaluation of motor difficulty in childhood (9-12 years old children ) by interview score on motor skills and soft neurological signs--aim for the diagnosis of developmental coordination disorder].

    Science.gov (United States)

    Kashiwagi, Mitsuru; Suzuki, Shuhei

    2009-09-01

    Many children with developmental disorders are known to have motor impairment such as clumsiness and poor physical ability;however, the objective evaluation of such difficulties is not easy in routine clinical practice. In this study, we aimed to establish a simple method for evaluating motor difficulty of childhood. This method employs a scored interview and examination for detecting soft neurological signs (SNSs). After a preliminary survey with 22 normal children, we set the items and the cutoffs for the interview and SNSs. The interview consisted of questions pertaining to 12 items related to a child's motor skills in his/her past and current life, such as skipping, jumping a rope, ball sports, origami, and using chopsticks. The SNS evaluation included 5 tests, namely, standing on one leg with eyes closed, diadochokinesia, associated movements during diadochokinesia, finger opposition test, and laterally fixed gaze. We applied this method to 43 children, including 25 cases of developmental disorders. Children showing significantly high scores in both the interview and SNS were assigned to the "with motor difficulty" group, while those with low scores in both the tests were assigned to the "without motor difficulty" group. The remaining children were assigned to the "with suspicious motor difficulty" group. More than 90% of the children in the "with motor difficulty" group had high impairment scores in Movement Assessment Battery for Children (M-ABC), a standardized motor test, whereas 82% of the children in the "without motor difficulty" group revealed no motor impairment. Thus, we conclude that our simple method and criteria would be useful for the evaluation of motor difficulty of childhood. Further, we have discussed the diagnostic process for developmental coordination disorder using our evaluation method.

  12. Simple saponification method for the quantitative determination of carotenoids in green vegetables.

    Science.gov (United States)

    Larsen, Erik; Christensen, Lars P

    2005-08-24

    A simple, reliable, and gentle saponification method for the quantitative determination of carotenoids in green vegetables was developed. The method involves an extraction procedure with acetone and the selective removal of the chlorophylls and esterified fatty acids from the organic phase using a strongly basic resin (Ambersep 900 OH). Extracts from common green vegetables (beans, broccoli, green bell pepper, chive, lettuce, parsley, peas, and spinach) were analyzed by high-performance liquid chromatography (HPLC) for their content of major carotenoids before and after action of Ambersep 900 OH. The mean recovery percentages for most carotenoids [(all-E)-violaxanthin, (all-E)-lutein epoxide, (all-E)-lutein, neolutein A, and (all-E)-beta-carotene] after saponification of the vegetable extracts with Ambersep 900 OH were close to 100% (99-104%), while the mean recovery percentages of (9'Z)-neoxanthin increased to 119% and that of (all-E)-neoxanthin and neolutein B decreased to 90% and 72%, respectively.

  13. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue.

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-10

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  14. The BUME method: a new rapid and simple chloroform-free method for total lipid extraction of animal tissue

    Science.gov (United States)

    Löfgren, Lars; Forsberg, Gun-Britt; Ståhlman, Marcus

    2016-06-01

    In this study we present a simple and rapid method for tissue lipid extraction. Snap-frozen tissue (15-150 mg) is collected in 2 ml homogenization tubes. 500 μl BUME mixture (butanol:methanol [3:1]) is added and automated homogenization of up to 24 frozen samples at a time in less than 60 seconds is performed, followed by a 5-minute single-phase extraction. After the addition of 500 μl heptane:ethyl acetate (3:1) and 500 μl 1% acetic acid a 5-minute two-phase extraction is performed. Lipids are recovered from the upper phase by automated liquid handling using a standard 96-tip robot. A second two-phase extraction is performed using 500 μl heptane:ethyl acetate (3:1). Validation of the method showed that the extraction recoveries for the investigated lipids, which included sterols, glycerolipids, glycerophospholipids and sphingolipids were similar or better than for the Folch method. We also applied the method for lipid extraction of liver and heart and compared the lipid species profiles with profiles generated after Folch and MTBE extraction. We conclude that the BUME method is superior to the Folch method in terms of simplicity, through-put, automation, solvent consumption, economy, health and environment yet delivering lipid recoveries fully comparable to or better than the Folch method.

  15. About the method of approximation of a simple closed plane curve with a sharp edge

    Directory of Open Access Journals (Sweden)

    Zelenyy A.S.

    2017-02-01

    Full Text Available it was noted in the article, that initially the problem of interpolation of the simple plane curve arose in the problem of simulation of subsonic flow around a body with the subsequent calculation of the velocity potential using the vortex panel method. However, as it turned out, the practical importance of this method is much wider. This algorithm can be successfully applied in any task that requires a discrete set of points which describe an arbitrary curve: potential function method, flow around an airfoil with the trailing edge (airfoil, liquid drop, etc., analytic expression, which is very difficult to obtain, creation of the font and logo and in some tasks of architecture and garment industry.

  16. Development of Gravity Acceleration Measurement Using Simple Harmonic Motion Pendulum Method Based on Digital Technology and Photogate Sensor

    Science.gov (United States)

    Yulkifli; Afandi, Zurian; Yohandri

    2018-04-01

    Development of gravitation acceleration measurement using simple harmonic motion pendulum method, digital technology and photogate sensor has been done. Digital technology is more practical and optimizes the time of experimentation. The pendulum method is a method of calculating the acceleration of gravity using a solid ball that connected to a rope attached to a stative pole. The pendulum is swung at a small angle resulted a simple harmonic motion. The measurement system consists of a power supply, Photogate sensors, Arduino pro mini and seven segments. The Arduino pro mini receives digital data from the photogate sensor and processes the digital data into the timing data of the pendulum oscillation. The calculation result of the pendulum oscillation time is displayed on seven segments. Based on measured data, the accuracy and precision of the experiment system are 98.76% and 99.81%, respectively. Based on experiment data, the system can be operated in physics experiment especially in determination of the gravity acceleration.

  17. Control of the large renal vein in limited dissected space during laparoscopic nephrectomy: a simple and reliable method

    NARCIS (Netherlands)

    Kijvikai, Kittinut; Laguna, M. Pilar; de la Rosette, Jean

    2006-01-01

    We describe our technique for large renal vein control in the limited dissected space during laparoscopic nephrectomy. This technique is a simple, inexpensive and reliable method, especially for large and short renal vein ligation

  18. A simple method employed for the treatment of filters used in atmospheric pollution studies

    International Nuclear Information System (INIS)

    Prendez B, M.M.; Ortiz C, J.L.; Garrido, J.I.; Huerta P, R.; Alvarez B, C.; Zolezzi C, S.R.

    1983-01-01

    A simple and rapid method for the multielement routine analysis of atmospheric particulate matter is described. The samples collected on four different types of filters were treated with HNO 3 and HCl at 110-120 deg C in pyrex glassware. Time required for the different stages of the treatment was determined by using 60 Co, 65 Zn and 137 Cs as radioactive tracers. Atomic absorption spectrophotometry was used to determine the concentration of the elements. The efficiency for 11 elements (Mg, Cr, Mn, Fe, Co, Ni, Cu, Zn, Cd, Hg and Pb) was determined. The method was succesfully employed for the treatment of filters used in atmospheric pollution studies in both urban and rural areas. (author)

  19. Semer: a simple calculational tool for the economic evaluations of reactor systems and associated innovations

    International Nuclear Information System (INIS)

    Nisan, S.; Rouyer, J.L.

    2001-01-01

    This paper summarises part of our on-going investigations on the economic evaluations of various nuclear and fossil energy systems and related innovations. These investigations are principally concerned with the development of the code system SEMER and its validation. SEMER has been developed to furnish top management and project leaders a simple tool for cost evaluations enabling a choice between competitive technological options. The cost evaluation models, actually integrated in the SEMER system, already cover a very wide range of electricity producing systems and, where relevant, their associated fuel cycles: The ''global models'', allowing rapid but relatively approximate overall cost estimations (about 15 % error). These include: Almost all the electricity producing systems using fossil energies (Oil, Coal, Gas, including gas turbines with combined cycles); Nuclear reactor systems including all the French PWRs, HTRs, Compact PWRs, and PWRs for nuclear propulsion systems. (author)

  20. A simple and effective radiometric correction method to improve landscape change detection across sensors and across time

    Science.gov (United States)

    Chen, X.; Vierling, Lee; Deering, D.

    2005-01-01

    post fire chronosequence with normalized data. These findings indicate that the TIC method provides a simple, effective and repeatable method to create radiometrically comparable data sets for remote detection of landscape change. Compared to some previous relative radiometric normalization methods, this new method does not require high level programming and statistical skills, yet remains sensitive to landscape changes occurring over seasonal and inter-annual time scales. In addition, the TIC method maintains sensitivity to subtle changes in vegetation phenology and enables normalization even when invariant features are rare. While this normalization method allowed detection of a range of land use, land cover, and phenological/biophysical changes in the Siberian boreal forest region studied here, it is necessary to further examine images representing a wide variety of ecoregions to thoroughly evaluate the TIC method against other normalization schemes. ?? 2005 Elsevier Inc. All rights reserved.

  1. A method proposal for cumulative environmental impact assessment based on the landscape vulnerability evaluation

    International Nuclear Information System (INIS)

    Pavlickova, Katarina; Vyskupova, Monika

    2015-01-01

    Cumulative environmental impact assessment deals with the occasional use in practical application of environmental impact assessment process. The main reasons are the difficulty of cumulative impact identification caused by lack of data, inability to measure the intensity and spatial effect of all types of impacts and the uncertainty of their future evolution. This work presents a method proposal to predict cumulative impacts on the basis of landscape vulnerability evaluation. For this purpose, qualitative assessment of landscape ecological stability is conducted and major vulnerability indicators of environmental and socio-economic receptors are specified and valuated. Potential cumulative impacts and the overall impact significance are predicted quantitatively in modified Argonne multiple matrixes while considering the vulnerability of affected landscape receptors and the significance of impacts identified individually. The method was employed in the concrete environmental impact assessment process conducted in Slovakia. The results obtained in this case study reflect that this methodology is simple to apply, valid for all types of impacts and projects, inexpensive and not time-consuming. The objectivity of the partial methods used in this procedure is improved by quantitative landscape ecological stability evaluation, assignment of weights to vulnerability indicators based on the detailed characteristics of affected factors, and grading impact significance. - Highlights: • This paper suggests a method proposal for cumulative impact prediction. • The method includes landscape vulnerability evaluation. • The vulnerability of affected receptors is determined by their sensitivity. • This method can increase the objectivity of impact prediction in the EIA process

  2. Pressure and pain In Systemic sclerosis/Scleroderma - an evaluation of a simple intervention (PISCES: randomised controlled trial protocol

    Directory of Open Access Journals (Sweden)

    Alcacer-Pitarch Begonya

    2012-02-01

    Full Text Available Abstract Background Foot problems associated with Systemic Sclerosis (SSc/Scleroderma have been reported to be both common and disabling. There are only limited data describing specifically, the mechanical changes occurring in the foot in SSc. A pilot project conducted in preparation for this trial confirmed the previous reports of foot related impairment and reduced foot function in people with SSc and demonstrated a link to mechanical etiologies. To-date there have been no formal studies of interventions directed at the foot problems experienced by people with Systemic Sclerosis. The primary aim of this trial is to evaluate whether foot pain and foot-related health status in people with Systemic Sclerosis can be improved through the provision of a simple pressure-relieving insole. Methods The proposed trial is a pragmatic, multicenter, randomised controlled clinical trial following a completed pilot study. In four participating centres, 140 consenting patients with SSc and plantar foot pain will be randomised to receive either a commercially available pressure relieving and thermally insulating insole, or a sham insole with no cushioning or thermal properties. The primary end point is a reduction in pain measured using the Foot Function Index Pain subscale, 12 weeks after the start of intervention. Participants will complete the primary outcome measure (Foot Function Index pain sub-scale prior to randomisation and at 12 weeks post randomisation. Secondary outcomes include participant reported pain and disability as derived from the Manchester Foot Pain and Disability Questionnaire and plantar pressures with and without the insoles in situ. Discussion This trial protocol proposes a rigorous and potentially significant evaluation of a simple and readily provided therapeutic approach which, if effective, could be of a great benefit for this group of patients. Trial registration number ISRCTN: ISRCTN02824122

  3. Image quality evaluation of full reference algorithm

    Science.gov (United States)

    He, Nannan; Xie, Kai; Li, Tong; Ye, Yushan

    2018-03-01

    Image quality evaluation is a classic research topic, the goal is to design the algorithm, given the subjective feelings consistent with the evaluation value. This paper mainly introduces several typical reference methods of Mean Squared Error(MSE), Peak Signal to Noise Rate(PSNR), Structural Similarity Image Metric(SSIM) and feature similarity(FSIM) of objective evaluation methods. The different evaluation methods are tested by Matlab, and the advantages and disadvantages of these methods are obtained by analyzing and comparing them.MSE and PSNR are simple, but they are not considered to introduce HVS characteristics into image quality evaluation. The evaluation result is not ideal. SSIM has a good correlation and simple calculation ,because it is considered to the human visual effect into image quality evaluation,However the SSIM method is based on a hypothesis,The evaluation result is limited. The FSIM method can be used for test of gray image and color image test, and the result is better. Experimental results show that the new image quality evaluation algorithm based on FSIM is more accurate.

  4. Empirical evaluation methods in computer vision

    CERN Document Server

    Christensen, Henrik I

    2002-01-01

    This book provides comprehensive coverage of methods for the empirical evaluation of computer vision techniques. The practical use of computer vision requires empirical evaluation to ensure that the overall system has a guaranteed performance. The book contains articles that cover the design of experiments for evaluation, range image segmentation, the evaluation of face recognition and diffusion methods, image matching using correlation methods, and the performance of medical image processing algorithms. Sample Chapter(s). Foreword (228 KB). Chapter 1: Introduction (505 KB). Contents: Automate

  5. Estudo teórico das transições eletrônicas usando métodos simples e sofisticados Theoretical study of electronic transitions using simple and sophisticated methods

    Directory of Open Access Journals (Sweden)

    Nelson H. Morgon

    2013-01-01

    Full Text Available In this paper, the use of both simple and sophisticated models in the study of electronic transitions was explored for a set of molecular systems: C2H4, C4H4, C4H6, C6H6, C6H8, "C8", C60, and [H2NCHCH(CHCHkCHNH2]+, where k = 0 to 4. The simple model of the free particle (1D, 2D, and 3D boxes, rings or spherical surfaces, considering the boundary conditions, was found to yield similar results to the sophisticated theoretical methods such as EOM-CCSD/6-311++G** or TD(NStates=5,Root=1-M06-2X/6-311++G**.

  6. Simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum using an immobilized trypsin.

    Science.gov (United States)

    Shibata, Kaito; Naito, Takafumi; Okamura, Jun; Hosokawa, Seiji; Mineta, Hiroyuki; Kawakami, Junichi

    2017-11-30

    Proteomic approaches using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) without an immunopurification technique have not been applied to the determination of serum cetuximab. This study developed a simple and rapid LC-MS/MS method for the absolute determination of cetuximab in human serum and applied it to clinical settings. Surrogate peptides derived from cetuximab digests were selected using a Fourier transform mass spectrometer. Reduced-alkylated serum cetuximab without immunopurification was digested for 20minutes using immobilized trypsin, and the digestion products were purified by solid-phase extraction. The LC-MS/MS was run in positive ion multiple reaction monitoring mode. This method was applied to the determination of serum samples in head and neck cancer patients treated with cetuximab. The chromatographic run time was 10minutes and no peaks interfering with surrogate peptides in serum digestion products were observed. The calibration curve of absolute cetuximab in serum was linear over the concentration range of 4-200μg/mL. The lower limit of quantification of cetuximab in human serum was 4μg/mL. The intra-assay and inter-assay precision and accuracy were less than 13.2% and 88.0-100.7%, respectively. The serum concentration range of cetuximab was 19-140μg/mL in patients. The serum cetuximab concentrations in LC-MS/MS were correlated with those in ELISA (r=0.899, P <0.01) and the mean bias was 1.5% in cancer patients. In conclusion, the present simple and rapid method with acceptable analytical performance can be helpful for evaluating the absolute concentration of serum cetuximab in clinical settings. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. A simple and rapid approach to evaluate the in vitro in vivo role of release controlling agent ethyl cellulose ether derivative polymer.

    Science.gov (United States)

    Akhlaq, Muhammad; Khan, Gul Majid; Jan, Syed Umer; Wahab, Abdul; Hussain, Abid; Nawaz, Asif; Abdelkader, Hamdy

    2014-11-01

    Diclofenac sodium (DCL-Na) conventional oral tablets exhibit serious side effects when given for a longer period leading to noncompliance. Controlled release matrix tablets of diclofenac sodium were formulated using simple blending (F-1), solvent evaporation (F-2) and co-precipitation techniques (F-3). Ethocel® Standard 7 FP Premium Polymer (15%) was used as a release controlling agent. Drug release study was conducted in 7.4 pH phosphate buffer solutions as dissolution medium in vitro. Pharmacokinetic parameters were evaluated using albino rabbits. Solvent evaporation technique was found to be the best release controlling technique thereby prolonging the release rate up to 24 hours. Accelerated stability studies of the optimized test formulation (F-2) did not show any significant change (prelease rate when stored for six months. A simple and rapid method was developed for DCL-Na active moiety using HPLC-UV at 276nm. The optimized test tablets (F-2) significantly (prelease. The study showed that once-daily controlled release matrix tablets of DCL-Na were successfully developed using Ethocel® Standard 7 FP Premium.

  8. A simple and effective method for detecting precipitated proteins in MALDI-TOF MS.

    Science.gov (United States)

    Oshikane, Hiroyuki; Watabe, Masahiko; Nakaki, Toshio

    2018-04-01

    MALDI-TOF MS has developed rapidly into an essential analytical tool for the life sciences. Cinnamic acid derivatives are generally employed in routine molecular weight determinations of intact proteins using MALDI-TOF MS. However, a protein of interest may precipitate when mixed with matrix solution, perhaps preventing MS detection. We herein provide a simple approach to enable the MS detection of such precipitated protein species by means of a "direct deposition method" -- loading the precipitant directly onto the sample plate. It is thus expected to improve routine MS analysis of intact proteins. Copyright © 2018. Published by Elsevier Inc.

  9. A simple method to prepare self-assembled organic-organic heterobilayers on metal substrates

    Directory of Open Access Journals (Sweden)

    L. D. Sun

    2011-06-01

    Full Text Available We demonstrate a self-assembly based simple method to prepare organic-organic heterobilayers on a metal substrate. By either sequential- or co-deposition of para-sexiphenyl (p-6P and pentacene molecules onto the Cu(110 surface in ultrahigh vacuum, p-6P/pentacene/Cu(110 heterobilayer is synthesized at room temperature. The layer sequence of the heterostructure is independent of the growth scenario indicating the p-6P/pentacene/Cu(110 is a self-assembled structure with lowest energy. Besides, the bilayer shows a very high orientational ordering and is thermally stable up to 430K.

  10. Rapid and simple method for quantitative evaluation of neurocytotoxic effects of radiation on developing medaka brain

    International Nuclear Information System (INIS)

    Yasuda, Takako; Maeda, Keiko; Matsumoto, Atsuko; Maruyama, Kouichi; Ishikawa, Yuji; Yoshimoto, Masami

    2008-01-01

    We describe a novel method for rapid and quantitative evaluation of the degree of radiation-induced apoptosis in the developing brain of medaka (Oryzias latipes). Embryos at stage 28 were irradiated with 1, 2, 3.5, and 5 Gy x-ray. Living embryos were stained with a vital dye, acridine orange (AO), for 1-2 h, and whole-mount brains were examined under an epifluorescence microscope. From 7 to 10 h after irradiation with 5 Gy x-ray, we found two morphologically different types of AO-stained structures, namely, small single nuclei and rosette-shaped nuclear clusters. Electron microscopy revealed that these two distinct types of structures were single apoptotic cells with condensed nuclei and aggregates of apoptotic cells, respectively. From 10 to 30 h after irradiation, a similar AO-staining pattern was observed. The numbers of AO-stained rosette-shaped nuclear clusters and AO-stained single nuclei increased in a dose-dependent manner in the optic tectum. We used the number of AO-stained rosette-shaped nuclear clusters/optic tectum as an index of the degree of radiation-induced brain cell death at 20-24 h after irradiation. The results showed that the number of rosette-shaped nuclear clusters/optic tectum in irradiated embryos exposed to 2 Gy or higher doses was highly significant compared to the number in nonirradiated control embryos, whereas no difference was detected at 1 Gy. Thus, the threshold dose for brain cell death in medaka embryos was taken as being between 1-2 Gy, which may not be so extraordinarily large compared to those for rodents and humans. The results show that medaka embryos are useful for quantitative evaluation of developmental neurocytotoxic effects of radiation. (author)

  11. A simple and convenient method for the simultaneous in vitro study of metformin and glimepiride tablets.

    Science.gov (United States)

    Ahmed, Rehan

    2014-11-01

    A simple and convenient method was developed for the simultaneous determination of metformin HCl and glimepiride in tablet dosage form of different pharmaceuticals companies. This method was validated and proved to be applicable for assay determination in intermediate and finished staged. More over a single medium dissolution of metformin HCl and glimepiride was established and the media was evaluated for comparative studies for different formulations. Reverse phase HPLC equipped with UV detector was used for the determination of metformin HCl and glimepiride. A mixture of acetonitrile and ammonium acetate buffer 0.05M pH 3.0 was used as mobile phase at flow rate of 1.0ml/min. Promocil C18 5µ 100Aº 4.6 x 100mm C18 silica column was used and detection was carried out at 270nm. Method was found to be linear over the range of 4ppm to 16ppm for glimepiride and 170ppm to 680ppm for metformin HCl. Regression co-efficient were found to be 0.9949 and 0.9864 for glimepiride and metformin HCl respectively. Dissolution was performed in 500ml 0.2% sodium lauryl sulfate at 37°C for 45min using paddle apparatus. Dissolution of glimepiride was found to be 98.60% and 101.08% in Orinase Met1 tablet and Amaryl M tablet respectively whereas metformin was found 99.41% and 98.59% in Orinase Met 1 tablet and Amaryl M tablet. RSD for all the dissolutions was less than 2.0% after completion.

  12. Echocardiographic evaluation of simple versus complex congenital heart disease in a tertiary care Paediatrics Hospital

    Directory of Open Access Journals (Sweden)

    Uttam Kumar Sarkar

    2017-10-01

    Full Text Available Background & Objectives:Congenital heart diseases are treatable either by catheter based intervention or open heart surgery according to their quality. In our study we aim to analyze congenital heart disease echocardiographically into simple versus complex heart disease at a tertiary care centre with a public health planning and policy making perspective.Materials & Methods:This hospital based study was done on 1010 patients, both from in-patient and out-patient, who were clinically suspected to have heart disease from January 2015 to September 2016 at Dr.B.C.Roy P.G.I.P.S. Kolkata and echocardiographically categorized.Results:A VSD was the commonest acyanotic heart disease (17. 08%.Tetralogy of Fallot (TOF was commonest complex cyanotic heart disease (10.64%, VSD +ASD was the commonest combined lesion (8.12%. Simple heart lesions (63.1% were commoner than complex (36.9% congenital heart diseases.Conclusion:Health policy makers should give due care to manage Congenital Heart Disease either catheter based or surgically keeping in mind about 63.1% of the lesions are simple cardiac lesions and 36.9% lesions are complex cardiac lesion where complex surgery is required. 

  13. Tracing and quantifying groundwater inflow into lakes using a simple method for radon-222 analysis

    Directory of Open Access Journals (Sweden)

    T. Kluge

    2007-09-01

    Full Text Available Due to its high activities in groundwater, the radionuclide 222Rn is a sensitive natural tracer to detect and quantify groundwater inflow into lakes, provided the comparatively low activities in the lakes can be measured accurately. Here we present a simple method for radon measurements in the low-level range down to 3 Bq m−3, appropriate for groundwater-influenced lakes, together with a concept to derive inflow rates from the radon budget in lakes. The analytical method is based on a commercially available radon detector and combines the advantages of established procedures with regard to efficient sampling and sensitive analysis. Large volume (12 l water samples are taken in the field and analyzed in the laboratory by equilibration with a closed air loop and alpha spectrometry of radon in the gas phase. After successful laboratory tests, the method has been applied to a small dredging lake without surface in- or outflow in order to estimate the groundwater contribution to the hydrological budget. The inflow rate calculated from a 222Rn balance for the lake is around 530 m³ per day, which is comparable to the results of previous studies. In addition to the inflow rate, the vertical and horizontal radon distribution in the lake provides information on the spatial distribution of groundwater inflow to the lake. The simple measurement and sampling technique encourages further use of radon to examine groundwater-lake water interaction.

  14. Criticality safety validation: Simple geometry, single unit 233U systems

    International Nuclear Information System (INIS)

    Putman, V.L.

    1997-06-01

    Typically used LMITCO criticality safety computational methods are evaluated for suitability when applied to INEEL 233 U systems which reasonably can be modeled as simple-geometry, single-unit systems. Sixty-seven critical experiments of uranium highly enriched in 233 U, including 57 aqueous solution, thermal-energy systems and 10 metal, fast-energy systems, were modeled. These experiments include 41 cylindrical and 26 spherical cores, and 41 reflected and 26 unreflected systems. No experiments were found for intermediate-neutron-energy ranges, or with interstitial non-hydrogenous materials typical of waste systems, mixed 233 U and plutonium, or reflectors such as steel, lead, or concrete. No simple geometry experiments were found with cubic or annular cores, or approximating infinite sea systems. Calculations were performed with various tools and methodologies. Nine cross-section libraries, based on ENDF/B-IV, -V, or -VI.2, or on Hansen-Roach source data, were used with cross-section processing methods of MCNP or SCALE. The k eff calculations were performed with neutral-particle transport and Monte Carlo methods of criticality codes DANT, MCNP 4A, and KENO Va

  15. Simple, rapid, and environmentally friendly method for the separation of isoflavones using ultra-high performance supercritical fluid chromatography.

    Science.gov (United States)

    Wu, Wenjie; Zhang, Yuan; Wu, Hanqiu; Zhou, Weie; Cheng, Yan; Li, Hongna; Zhang, Chuanbin; Li, Lulu; Huang, Ying; Zhang, Feng

    2017-07-01

    Isoflavones are natural substances that exhibit hormone-like pharmacological activities. The separation of isoflavones remains an analytical challenge because of their similar structures. We show that ultra-high performance supercritical fluid chromatography can be an appropriate tool to achieve the fast separation of 12 common dietary isoflavones. Among the five tested columns the Torus DEA column was found to be the most effective column for the separation of these isoflavones. The impact of individual parameters on the retention time and separation factor was evaluated. These parameters were optimized to develop a simple, rapid, and green method for the separation of the 12 target analytes. It only took 12.91 min using gradient elution with methanol as an organic modifier and formic acid as an additive. These isoflavones were determined with limit of quantitation ranging from 0.10 to 0.50 μg/mL, which was sufficient for reliable determination of various matrixes. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  16. Laserspritzer: a simple method for optogenetic investigation with subcellular resolutions.

    Directory of Open Access Journals (Sweden)

    Qian-Quan Sun

    Full Text Available To build a detailed circuit diagram in the brain, one needs to measure functional synaptic connections between specific types of neurons. A high-resolution circuit diagram should provide detailed information at subcellular levels such as soma, distal and basal dendrites. However, a limitation lies in the difficulty of studying long-range connections between brain areas separated by millimeters. Brain slice preparations have been widely used to help understand circuit wiring within specific brain regions. The challenge exists because long-range connections are likely to be cut in a brain slice. The optogenetic approach overcomes these limitations, as channelrhodopsin 2 (ChR2 is efficiently transported to axon terminals that can be stimulated in brain slices. Here, we developed a novel fiber optic based simple method of optogenetic stimulation: the laserspritzer approach. This method facilitates the study of both long-range and local circuits within brain slice preparations. This is a convenient and low cost approach that can be easily integrated with a slice electrophysiology setup, and repeatedly used upon initial validation. Our data with direct ChR2 mediated-current recordings demonstrates that the spatial resolution of the laserspritzer is correlated with the size of the laserspritzer, and the resolution lies within the 30 µm range for the 5 micrometer laserspritzer. Using olfactory cortical slices, we demonstrated that the laserspritzer approach can be applied to selectively activate monosynaptic perisomatic GABAergic basket synapses, or long-range intracortical glutamatergic inputs formed on different subcellular domains within the same cell (e.g. distal and proximal dendrites. We discuss significant advantages of the laserspritzer approach over the widely used collimated LED whole-field illumination method in brain slice electrophysiological research.

  17. A Simple and Fast Extraction Method for the Determination of Multiclass Antibiotics in Eggs Using LC-MS/MS.

    Science.gov (United States)

    Wang, Kun; Lin, Kunde; Huang, Xinwen; Chen, Meng

    2017-06-21

    The purpose of this study was to develop and validate a simple, fast, and specific extraction method for the analysis of 64 antibiotics from nine classes (including sulfonamides, quinolones, tetracyclines, macrolides, lincosamide, nitrofurans, β-lactams, nitromidazoles, and cloramphenicols) in chicken eggs. Briefly, egg samples were simply extracted with a mixture of acetonitrile-water (90:10, v/v) and 0.1 mol·L -1 Na 2 EDTA solution assisted with ultrasonic. The extract was centrifuged, condensed, and directly analyzed on a liquid chromatography coupled to tandem mass spectrometry. Compared with conventional cleanup methods (passing through solid phase extract cartridges), the established method demonstrated comparable efficiencies in eliminating matrix effects and higher or equivalent recoveries for most of the target compounds. Typical validation parameters including specificity, linearity, matrix effect, limits of detection (LODs) and quantification (LOQs), the decision limit, detection capability, trueness, and precision were evaluated. The recoveries of target compounds ranged from 70.8% to 116.1% at three spiking levels (5, 20, and 50 μg·kg -1 ), with relative standard deviations less than 14%. LODs and LOQs were in the ranges of 0.005-2.00 μg·kg -1 and 0.015-6.00 μg·kg -1 for all of the antibiotics, respectively. A total of five antibiotics were successfully detected in 22 commercial eggs from local markets. This work suggests that the method is suitable for the analysis of multiclass antibiotics in eggs.

  18. Semer: a simple calculational tool for the economic evaluations of reactor systems and associated innovations

    Energy Technology Data Exchange (ETDEWEB)

    Nisan, S. [CEA Cadarache, Nuclear Reactor Directorate, DRN, Dept. of Reactor Studies, DER, Reactor and Innovative Systems Service, SERSI, 13 - Saint Paul lez Durance (France); Rouyer, J.L. [Electricite de France (EDF), Pole Industrie, Div. Ingenierie et Services, 93 - Saint-Denis (France)

    2001-07-01

    This paper summarises part of our on-going investigations on the economic evaluations of various nuclear and fossil energy systems and related innovations. These investigations are principally concerned with the development of the code system SEMER and its validation. SEMER has been developed to furnish top management and project leaders a simple tool for cost evaluations enabling a choice between competitive technological options. The cost evaluation models, actually integrated in the SEMER system, already cover a very wide range of electricity producing systems and, where relevant, their associated fuel cycles: The ''global models'', allowing rapid but relatively approximate overall cost estimations (about 15 % error). These include: Almost all the electricity producing systems using fossil energies (Oil, Coal, Gas, including gas turbines with combined cycles); Nuclear reactor systems including all the French PWRs, HTRs, Compact PWRs, and PWRs for nuclear propulsion systems. (author)

  19. A rapid and simple separation method of Tc-99 in water samples

    International Nuclear Information System (INIS)

    Uchida, Shigeo; Tagami, Keiko

    1999-01-01

    Technetium-99 ( 99 Tc) is one of the important elements on safety evaluation of reprocessing plant and waste disposal plant, because it is a long half-life nuclide and large fission yield (about 6%) from 235 U and 239 Pu. We studied in this work a rapid and simple separation method of 99 Tc in water samples by ICP-MS. Tc in 2 litre of inland water or 1.5 litre of sea water sample solutions was condensed and separated by mini-column resin (TEVA·Spec resin) (Eichrom Co., Ltd.). The experimental results showed the best conditions as followed that 1) after controlling 0.1M nitric acid sample solution, passed it through the column, 2) then the inhibitory elements such as Ru are removed by 40 ml of 2M nitric acid solution, and 3) Tc was recovered by 4 ml of 8M nitric acid solution. 95% or more recovery of Tc was obtained. 100% Ru, an inhibited element of ICP-MS, was removed. The elute obtained from 4 ml of 8M nitric acid solution was diluted ten times with pure water and 99 Tc was measured by ICP-MS. The limit of detection of 2 litre inland water and 1.5 litre sea water were 3 mBql -1 and 4 mBql -1 , respectively. The organic compounds were not removed before running to column, because the concentration of organic compounds was not so large. When large amounts of them are contained, they should be removed. If suspended materials absorb Tc, Tc should be changed to TcO 4 - . (S.Y.)

  20. Simple and non-invasive techniques to evaluate the function of CircuLite Synergy.

    Science.gov (United States)

    Mohite, Prashant N; Bowles, Christopher T; Sabashnikov, Anton; Popov, Aron-Frederik; Patil, Nikhil P; Sáez, Diana García; Banner, Nicholas R; Simon, André R

    2014-11-01

    The Synergy CircuLite micropump is a novel partial-support miniature left ventricular assist device that propels 2-3 l/min blood from the left atrium into the right subclavian artery. The ability of currently available investigative modalities to confirm Synergy pump malfunction is limited. The Synergy speed fluctuates periodically (at 10-s intervals) from the baseline to a transient decrease followed by a transient increase (alternating speed algorithm, ASA) with the purpose of changing the blood flow behaviour, thereby reducing thrombogenicity. The aim of this study was to develop a simple non-invasive monitoring technique to assess pump function based on the detection of the ASA in the peripheral microcirculation. Between February 2012 and July 2013, 10 patients with advanced chronic heart failure underwent Synergy implantation at our institution. The pump function was assessed by echocardiography and invasive monitoring according to standard protocols; additionally, the pump speed and power consumption were monitored. During the pump function assessment, the pulse oximeter waveform was recorded from the index fingers of the left and right hand with simultaneous pump auscultation using a stethoscope positioned on the pump (right infra-clavicular pocket). The pulse oximeter waveform was readily detectable from the right and left hand of all study patients. If the Synergy function was normal, there was a significant difference in the morphology of the pulse oximeter waveform from each hand: the ASA algorithm produced a more pronounced variation (giant wave) in the trace from the right hand than from the left. The giant waves invariably coincided with the sound variation associated with the ASA algorithms, which were detected regularly at 10-s intervals. We describe a simple, readily applicable, inexpensive, non-invasive technique that allows evaluation of Synergy pump function and may have diagnostic utility under conditions of suspected pump thrombus

  1. Consumer behavior changing: methods of evaluation

    Directory of Open Access Journals (Sweden)

    Elīna Gaile-Sarkane

    2013-11-01

    Full Text Available The article is devoted to methods of analyses of consumer buying behavior as well as to evaluation of most important factors what influences consumer behavior. This research aims at investigations about the changes in consumer behavior caused by globalization and development of information technologies; it helps to understand the specific factors what should be taken into account in evaluation of consumer behavior. The authors employ well-established quantitative and qualitative methods of research: grouping, analysis, synthesis, expert method, statistic method, etc. Research findings disclosed that there is possibility to introduce new methods for evaluation of changing consumer behavior.

  2. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    Science.gov (United States)

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  3. Proton dose distribution measurements using a MOSFET detector with a simple dose‐weighted correction method for LET effects

    Science.gov (United States)

    Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-01-01

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth‐dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high‐bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L‐shaped bolus. The dose reproducibility, angular dependence and depth‐dose response were evaluated using a 190 MeV proton beam. Depth‐output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose‐weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L‐shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors. PACS number: 87.56.‐v

  4. A Simple Method to Estimate Large Fixed Effects Models Applied to Wage Determinants and Matching

    OpenAIRE

    Mittag, Nikolas

    2016-01-01

    Models with high dimensional sets of fixed effects are frequently used to examine, among others, linked employer-employee data, student outcomes and migration. Estimating these models is computationally difficult, so simplifying assumptions that are likely to cause bias are often invoked to make computation feasible and specification tests are rarely conducted. I present a simple method to estimate large two-way fixed effects (TWFE) and worker-firm match effect models without additional assum...

  5. A human-machine interface evaluation method: A difficulty evaluation method in information searching (DEMIS)

    International Nuclear Information System (INIS)

    Ha, Jun Su; Seong, Poong Hyun

    2009-01-01

    A human-machine interface (HMI) evaluation method, which is named 'difficulty evaluation method in information searching (DEMIS)', is proposed and demonstrated with an experimental study. The DEMIS is based on a human performance model and two measures of attentional-resource effectiveness in monitoring and detection tasks in nuclear power plants (NPPs). Operator competence and HMI design are modeled to be most significant factors to human performance. One of the two effectiveness measures is fixation-to-importance ratio (FIR) which represents attentional resource (eye fixations) spent on an information source compared to importance of the information source. The other measure is selective attention effectiveness (SAE) which incorporates FIRs for all information sources. The underlying principle of the measures is that the information source should be selectively attended to according to its informational importance. In this study, poor performance in information searching tasks is modeled to be coupled with difficulties caused by poor mental models of operators or/and poor HMI design. Human performance in information searching tasks is evaluated by analyzing the FIR and the SAE. Operator mental models are evaluated by a questionnaire-based method. Then difficulties caused by a poor HMI design are evaluated by a focused interview based on the FIR evaluation and then root causes leading to poor performance are identified in a systematic way.

  6. Evaluation of a simple protein extraction method for species identification of clinically relevant staphylococci by matrix-assisted laser desorption ionization-time of flight mass spectrometry.

    Science.gov (United States)

    Matsuda, Naoto; Matsuda, Mari; Notake, Shigeyuki; Yokokawa, Hirohide; Kawamura, Yoshiaki; Hiramatsu, Keiichi; Kikuchi, Ken

    2012-12-01

    In clinical microbiology, bacterial identification is labor-intensive and time-consuming. A solution for this problem is the use of matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS). In this study, we evaluated a modified protein extraction method of identification performed on target plates (on-plate extraction method) with MALDI-TOF (Bruker Microflex LT with Biotyper version 3.0) and compared it to 2 previously described methods: the direct colony method and a standard protein extraction method (standard extraction method). We evaluated the species of 273 clinical strains and 14 reference strains of staphylococci. All isolates were characterized using the superoxide dismutase A sequence as a reference. For the species identification, the on-plate, standard extraction, and direct colony methods identified 257 isolates (89.5%), 232 isolates (80.8%), and 173 isolates (60.2%), respectively, with statistically significant differences among the three methods (P extraction method is at least as good as standard extraction in identification rate and has the advantage of a shorter processing time.

  7. A simple model for indentation creep

    Science.gov (United States)

    Ginder, Ryan S.; Nix, William D.; Pharr, George M.

    2018-03-01

    A simple model for indentation creep is developed that allows one to directly convert creep parameters measured in indentation tests to those observed in uniaxial tests through simple closed-form relationships. The model is based on the expansion of a spherical cavity in a power law creeping material modified to account for indentation loading in a manner similar to that developed by Johnson for elastic-plastic indentation (Johnson, 1970). Although only approximate in nature, the simple mathematical form of the new model makes it useful for general estimation purposes or in the development of other deformation models in which a simple closed-form expression for the indentation creep rate is desirable. Comparison to a more rigorous analysis which uses finite element simulation for numerical evaluation shows that the new model predicts uniaxial creep rates within a factor of 2.5, and usually much better than this, for materials creeping with stress exponents in the range 1 ≤ n ≤ 7. The predictive capabilities of the model are evaluated by comparing it to the more rigorous analysis and several sets of experimental data in which both the indentation and uniaxial creep behavior have been measured independently.

  8. Theoretical comparison of performance using transfer functions for reactivity meters based on inverse kinetic method and simple feedback method

    International Nuclear Information System (INIS)

    Shimazu, Yoichiro; Tashiro, Shoichi; Tojo, Masayuki

    2017-01-01

    The performance of two digital reactivity meters, one based on the conventional inverse kinetic method and the other one based on simple feedback theory, are compared analytically using their respective transfer functions. The latter one is proposed by one of the authors. It has been shown that the performance of the two reactivity meters become almost identical when proper system parameters are selected for each reactivity meter. A new correlation between the system parameters of the two reactivity meters is found. With this correlation, filter designers can easily determine the system parameters for the respective reactivity meters to obtain identical performance. (author)

  9. Five year prediction of Sea Surface Temperature in the Tropical Atlantic: a comparison of simple statistical methods

    OpenAIRE

    Laepple, Thomas; Jewson, Stephen; Meagher, Jonathan; O'Shay, Adam; Penzer, Jeremy

    2007-01-01

    We are developing schemes that predict future hurricane numbers by first predicting future sea surface temperatures (SSTs), and then apply the observed statistical relationship between SST and hurricane numbers. As part of this overall goal, in this study we compare the historical performance of three simple statistical methods for making five-year SST forecasts. We also present SST forecasts for 2006-2010 using these methods and compare them to forecasts made from two structural time series ...

  10. A simple and accurate grading system for orthoiodohippurate renal scans in the assessment of post-transplant renal function

    International Nuclear Information System (INIS)

    Zaki, S.K.; Bretan, P.N.; Go, R.T.; Rehm, P.K.; Streem, S.B.; Novick, A.C.

    1990-01-01

    Orthoiodohippurate renal scanning has proved to be a reliable, noninvasive method for the evaluation and followup of renal allograft function. However, a standardized system for grading renal function with this test is not available. We propose a simple grading system to distinguish the different functional phases of hippurate scanning in renal transplant recipients. This grading system was studied in 138 patients who were evaluated 1 week after renal transplantation. There was a significant correlation between the isotope renographic functional grade and clinical correlates of allograft function such as the serum creatinine level (p = 0.0001), blood urea nitrogen level (p = 0.0001), urine output (p = 0.005) and need for hemodialysis (p = 0.007). We recommend this grading system as a simple and accurate method to interpret orthoiodohippurate renal scans in the evaluation and followup of renal allograft recipients

  11. An Alternative Method of Intermaxillary Fixation for Simple Pediatric Mandible Fractures.

    Science.gov (United States)

    Farber, Scott J; Nguyen, Dennis C; Harvey, Alan A; Patel, Kamlesh B

    2016-03-01

    Mandibular fractures represent a substantial portion of facial fractures in the pediatric population. Pediatric mandibles differ from their adult counterparts in the presence of mixed dentition. Avoidance of injury to developing tooth follicles is critical. Simple mandibular fractures can be treated with intermaxillary fixation (IMF) using arch bars or bone screws. This report describes an alternative to these methods using silk sutures and an algorithm to assist in treating simple mandibular fractures in the pediatric population. A retrospective chart review was performed and the records of 1 surgeon were examined. Pediatric patients who underwent treatment for a mandibular fracture in the operating room from 2011 to 2015 were identified using Common Procedural Terminology codes. Data collected included age, gender, type of fracture, type of treatment used, duration of fixation, and presence of complications. Five patients with a mean age of 6.8 years at presentation were identified. Fracture types were unilateral fractures of the condylar neck (n = 3), bilateral fractures of the condylar head (n = 1), and a unilateral fracture of the condylar head with an associated parasymphyseal fracture (n = 1). IMF was performed in 4 patients using silk sutures, and bone screw fixation was performed in the other patient. No post-treatment complications or malocclusion were reported. Average duration of IMF was 18.5 days. An algorithm is presented to assist in the treatment of pediatric mandibular fractures. Silk suture fixation is a viable and safe alternative to arch bars or bone screws for routine mandibular fractures. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. New method to evaluate the 7Li(p, n)7Be reaction near threshold

    International Nuclear Information System (INIS)

    Herrera, María S.; Moreno, Gustavo A.; Kreiner, Andrés J.

    2015-01-01

    In this work a complete description of the 7 Li(p, n) 7 Be reaction near threshold is given using center-of-mass and relative coordinates. It is shown that this standard approach, not used before in this context, leads to a simple mathematical representation which gives easy access to all relevant quantities in the reaction and allows a precise numerical implementation. It also allows in a simple way to include proton beam-energy spread affects. The method, implemented as a C++ code, was validated both with numerical and experimental data finding a good agreement. This tool is also used here to analyze scattered published measurements such as (p, n) cross sections, differential and total neutron yields for thick targets. Using these data we derive a consistent set of parameters to evaluate neutron production near threshold. Sensitivity of the results to data uncertainty and the possibility of incorporating new measurements are also discussed

  13. A Simple Halide-to-Anion Exchange Method for Heteroaromatic Salts and Ionic Liquids

    Directory of Open Access Journals (Sweden)

    Neus Mesquida

    2012-04-01

    Full Text Available A broad and simple method permitted halide ions in quaternary heteroaromatic and ammonium salts to be exchanged for a variety of anions using an anion exchange resin (A− form in non-aqueous media. The anion loading of the AER (OH− form was examined using two different anion sources, acids or ammonium salts, and changing the polarity of the solvents. The AER (A− form method in organic solvents was then applied to several quaternary heteroaromatic salts and ILs, and the anion exchange proceeded in excellent to quantitative yields, concomitantly removing halide impurities. Relying on the hydrophobicity of the targeted ion pair for the counteranion swap, organic solvents with variable polarity were used, such as CH3OH, CH3CN and the dipolar nonhydroxylic solvent mixture CH3CN:CH2Cl2 (3:7 and the anion exchange was equally successful with both lipophilic cations and anions.

  14. Simple and ultra-fast recognition and quantitation of compounded monoclonal antibodies: Application to flow injection analysis combined to UV spectroscopy and matching method.

    Science.gov (United States)

    Jaccoulet, E; Schweitzer-Chaput, A; Toussaint, B; Prognon, P; Caudron, E

    2018-09-01

    Compounding of monoclonal antibody (mAbs) constantly increases in hospital. Quality control (QC) of the compounded mAbs based on quantification and identification is required to prevent potential errors and fast method is needed to manage outpatient chemotherapy administration. A simple and ultra-fast (less than 30 s) method using flow injection analysis associated to least square matching method issued from the analyzer software was performed and evaluated for the routine hospital QC of three compounded mAbs: bevacizumab, infliximab and rituximab. The method was evaluated through qualitative and quantitative parameters. Preliminary analysis of the UV absorption and second derivative spectra of the mAbs allowed us to adapt analytical conditions according to the therapeutic range of the mAbs. In terms of quantitative QC, linearity, accuracy and precision were assessed as specified in ICH guidelines. Very satisfactory recovery was achieved and the RSD (%) of the intermediate precision were less than 1.1%. Qualitative analytical parameters were also evaluated in terms of specificity, sensitivity and global precision through a matrix of confusion. Results showed to be concentration and mAbs dependant and excellent (100%) specificity and sensitivity were reached within specific concentration range. Finally, routine application on "real life" samples (n = 209) from different batch of the three mAbs complied with the specifications of the quality control i.e. excellent identification (100%) and ± 15% of targeting concentration belonging to the calibration range. The successful use of the combination of second derivative spectroscopy and partial least square matching method demonstrated the interest of FIA for the ultra-fast QC of mAbs after compounding using matching method. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. A simple method to evaluate the fission gas release at fuel grain boundary including the grain growth both at constant and at transient power histories

    International Nuclear Information System (INIS)

    Paraschiv, M.; Paraschiv, A.

    1991-01-01

    A method to rewrite Fick's second law for a region with a moving boundary when the moving law in time of this boundary is known, has been proposed. This method was applied to Booth's sphere model for radioactive and stable fission product diffusion from the oxide fuel grain in order to take into account the grain growth. The solution of this new equation was presented in the mathematical formulation for power histories from ANS 5.4 model for the stable species. It is very simple to apply and very accurate. The results obtained with this solution for constant and transient temperatures show that the fission gas release (FGR) at grain boundary is strongly dependent on kinetics of grain growth. The utilization of two semiempirical grain growth laws, from published information, shows that the fuel microstructural properties need to be multicitly considered in the fission gas release for every manufacturer of fuel. (orig.)

  16. Sistem Pendukung Keputusan Evaluasi Pemilihan Pemenang Pengadaan Aset dengan Metode Simple Additive Weighting (SAW

    Directory of Open Access Journals (Sweden)

    Fajar Nugraha

    2014-02-01

    Full Text Available Procurement of assets by auction requires a decision support in selecting the winning bidder so that decision makers can pick and choose the winner of the auction. This study aims to develop a Decision Support System (DSS, which serves as an aid in decision mak ing in the process  of  evaluating  the  winning  bidder  acquisitions.  In order to  achieve  the  purpose  of  SPK  well  then helped  by  using  one  of  the methods in decision-making that is the method of Simple Additive weighting method (SAW to evaluate alternatives in the provision of asset  based  decision-making  criteria.  This  method  has  the  advantage  criteria  (benefits  and  cost  criteria  (cost.  Criteria  advantage (benefit is used when considering the aspects of decision making maximum profit. While the cost criteria (cost is the inver se of the attributes of an advantage, in this draft decision will be looking  for a minimal fee. The results may support the decision on the selection of an alternative evaluation of acquisitions winners based on predetermined criteria.Keywords: Acquisitions; Decision support systems; Simple additive weighting

  17. Thermalization calorimetry: A simple method for investigating glass transition and crystallization of supercooled liquids

    DEFF Research Database (Denmark)

    Jakobsen, Bo; Sanz, Alejandro; Niss, Kristine

    2016-01-01

    and their crystallization, e.g., for locating the glass transition and melting point(s), as well as for investigating the stability against crystallization and estimating the relative change in specific heat between the solid and liquid phases at the glass transition......We present a simple method for fast and cheap thermal analysis on supercooled glass-forming liquids. This “Thermalization Calorimetry” technique is based on monitoring the temperature and its rate of change during heating or cooling of a sample for which the thermal power input comes from heat...

  18. A simple method for conversion of airborne gamma-ray spectra to ground level doses

    DEFF Research Database (Denmark)

    Korsbech, Uffe C C; Bargholz, Kim

    1996-01-01

    A new and simple method for conversion of airborne NaI(Tl) gamma-ray spectra to dose rates at ground level has been developed. By weighting the channel count rates with the channel numbers a spectrum dose index (SDI) is calculated for each spectrum. Ground level dose rates then are determined...... by multiplying the SDI by an altitude dependent conversion factor. The conversion factors are determined from spectra based on Monte Carlo calculations. The results are compared with measurements in a laboratory calibration set-up. IT-NT-27. June 1996. 27 p....

  19. A simple method for the preparation of activated carbon fibers coated with graphite nanofibers.

    Science.gov (United States)

    Kim, Byung-Joo; Park, Soo-Jin

    2007-11-15

    A simple method is described for the preparation of activated carbon fibers (ACFs) coated with graphite nanofibers (GNFs). Low-pressure-plasma mixed-gas (Ar/O2) treatment of the ACFs led to the growth of GNFs on their surface. The growth was greater at higher power inputs, and from TEM observations the GNFs were seen to be of herringbone type. It was found that the N2 adsorption capacity of the ACFs did not sharply decrease, and that volume resistivity of the ACFs enhanced as a result of this treatment.

  20. Study of a new method for the evaluation of portal vein pressure by hepatic perfusion imaging

    International Nuclear Information System (INIS)

    Cheng Muhua; Ling Yunbiao; Pan Zhiheng; Zhang Feng; Chen Weizhen

    2002-01-01

    To study a new method for predication of portal vein pressure (PVP) by hepatic perfusion imaging. 25 hepato-cirrhotic cases and 13 normal controls were performed the hepatic perfusion imaging. According to two compartmental model the values of portal vein indexes (PVI) was calculated using curve slope, area and hepatic heart perfusion ratio methods etc. The relationship of PVI with different method to PVP was also observed. All PVI by three methods in hepatocirrhosis were higher than those in normal controls (P<0.01), and also positively correlated with the PVP, their correlated coefficients was 0.79, 0.60, 0.68 respectively. Among them the slope method was most markedly significant than normal control and closely correlated with PVP. PVI can sensitively reflect the changes of portal vein blood flow. And it was an atraumatic, simple method for the evaluation of PVP

  1. Simple arithmetic: not so simple for highly math anxious individuals.

    Science.gov (United States)

    Chang, Hyesang; Sprute, Lisa; Maloney, Erin A; Beilock, Sian L; Berman, Marc G

    2017-12-01

    Fluency with simple arithmetic, typically achieved in early elementary school, is thought to be one of the building blocks of mathematical competence. Behavioral studies with adults indicate that math anxiety (feelings of tension or apprehension about math) is associated with poor performance on cognitively demanding math problems. However, it remains unclear whether there are fundamental differences in how high and low math anxious individuals approach overlearned simple arithmetic problems that are less reliant on cognitive control. The current study used functional magnetic resonance imaging to examine the neural correlates of simple arithmetic performance across high and low math anxious individuals. We implemented a partial least squares analysis, a data-driven, multivariate analysis method to measure distributed patterns of whole-brain activity associated with performance. Despite overall high simple arithmetic performance across high and low math anxious individuals, performance was differentially dependent on the fronto-parietal attentional network as a function of math anxiety. Specifically, low-compared to high-math anxious individuals perform better when they activate this network less-a potential indication of more automatic problem-solving. These findings suggest that low and high math anxious individuals approach even the most fundamental math problems differently. © The Author (2017). Published by Oxford University Press.

  2. A Simple Analytical Method Using HPLC with Fluorescence Detection to Determine Selected Polycyclic Aromatic Compounds in Filter Samples; Metodo Analitico Sencillo para la Determinacion de Compuestos Aromaticos Policiclicos en Muestras de Filtros mediante HPLC con Detector de Fluorescencia

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, S.; Perez, R. M.

    2014-06-01

    A study on the comparison and evaluation of a miniaturized extraction method for the determination of selected PACs in sample filters is presented. The main objective was the optimization and development of simple, rapid and low cost methods, minimizing the use of extracting solvent volume. The work also includes a study on the intermediate precision. (Author)

  3. A simple and cost-effective method for fabrication of integrated electronic-microfluidic devices using a laser-patterned PDMS layer

    KAUST Repository

    Li, Ming

    2011-12-03

    We report a simple and cost-effective method for fabricating integrated electronic-microfluidic devices with multilayer configurations. A CO 2 laser plotter was employed to directly write patterns on a transferred polydimethylsiloxane (PDMS) layer, which served as both a bonding and a working layer. The integration of electronics in microfluidic devices was achieved by an alignment bonding of top and bottom electrode-patterned substrates fabricated with conventional lithography, sputtering and lift-off techniques. Processes of the developed fabrication method were illustrated. Major issues associated with this method as PDMS surface treatment and characterization, thickness-control of the transferred PDMS layer, and laser parameters optimization were discussed, along with the examination and testing of bonding with two representative materials (glass and silicon). The capability of this method was further demonstrated by fabricating a microfluidic chip with sputter-coated electrodes on the top and bottom substrates. The device functioning as a microparticle focusing and trapping chip was experimentally verified. It is confirmed that the proposed method has many advantages, including simple and fast fabrication process, low cost, easy integration of electronics, strong bonding strength, chemical and biological compatibility, etc. © Springer-Verlag 2011.

  4. Color image definition evaluation method based on deep learning method

    Science.gov (United States)

    Liu, Di; Li, YingChun

    2018-01-01

    In order to evaluate different blurring levels of color image and improve the method of image definition evaluation, this paper proposed a method based on the depth learning framework and BP neural network classification model, and presents a non-reference color image clarity evaluation method. Firstly, using VGG16 net as the feature extractor to extract 4,096 dimensions features of the images, then the extracted features and labeled images are employed in BP neural network to train. And finally achieve the color image definition evaluation. The method in this paper are experimented by using images from the CSIQ database. The images are blurred at different levels. There are 4,000 images after the processing. Dividing the 4,000 images into three categories, each category represents a blur level. 300 out of 400 high-dimensional features are trained in VGG16 net and BP neural network, and the rest of 100 samples are tested. The experimental results show that the method can take full advantage of the learning and characterization capability of deep learning. Referring to the current shortcomings of the major existing image clarity evaluation methods, which manually design and extract features. The method in this paper can extract the images features automatically, and has got excellent image quality classification accuracy for the test data set. The accuracy rate is 96%. Moreover, the predicted quality levels of original color images are similar to the perception of the human visual system.

  5. A quick and easy high performance liquid chromatography method for evaluation of cefixime in human plasma

    Directory of Open Access Journals (Sweden)

    Hossein Danafar

    2015-12-01

    Full Text Available Cefixime is essential member of orally energetic third generation cephalosporin and has tremendous activity aligned with many pathogens. The virtual bioavailability of a newly industrial dispersible tablet as compared with a recognized identified formulation.  A simple and available reversed-phase HPLC method with UV detection has been urbanized and validate for cefixime evaluate in human plasma using a C18 analytical column and a mobile phase of tetrabutylammonium hydroxide (pH 6.5-acetonitrile (3:1 v/v. The detection wavelength was 280 nm. To method observed major linear response-concentration association all through the cefixime concentration range of 15-100 ng/ml, with the average accuracy within-run and between-run values of 97.29% and 99.27%. The average drug recovery from plasma was 98.2% throughout the linear concentration range. The limits of detection (LOD and quantitation (LOQ of the method were 5 and 15 ng/ml, respectively. The method is quick, easy, very steady and precise for the partition, assignment, evaluation of cefixime in human plasma.

  6. A simple filtration method to remove plankton-associated Vibrio cholerae in raw water supplies in developing countries.

    Science.gov (United States)

    Huq, A; Xu, B; Chowdhury, M A; Islam, M S; Montilla, R; Colwell, R R

    1996-07-01

    Plankton to which cells of Vibrio cholerae O1 and/or O139 were attached was introduced into 0.5% Instant Ocean microcosms maintained at 25 degrees C. The bulk of the plankton and associated particulates was removed with a filter constructed from either nylon net and one of several different types of sari material, the latter being very inexpensive and readily available in villages in Bangladesh, where V. cholerae is endemic. V. cholerae was enumerated before and after filtration to evaluate the efficiency of the filtration procedure. The results obtained indicate that 99% of V. cholerae, i.e., those cells attached to plankton, were removed from the water samples. Epidemic strains of V. cholerae O1 and O139 from various geographical sources, including Bangladesh, Brazil, India, and Mexico, were included in the experiments. Removal of vibrios from water by this simple filtration method was found to yield consistent results with all strains examined in this study. Thus, it is concluded that a simple filtration procedure involving the use of domestic sari material can reduce the number of cholera vibrios attached to plankton in raw water from ponds and rivers commonly used for drinking. Since untreated water from such sources serves as drinking water for millions of people living in developing countries (e.g., Bangladesh), filtration should prove effective at reducing the incidence and severity of outbreaks, especially in places that lack fuel wood for boiling water and/or municipal water treatment plants. The results of this study provide the basis for determining such reductions, which are to be carried out in the near future.

  7. A simple, reproducible and sensitive spectrophotometric method to estimate microalgal lipids

    Energy Technology Data Exchange (ETDEWEB)

    Chen Yimin [ChELSI Institute, Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom); Vaidyanathan, Seetharaman, E-mail: s.vaidyanathan@sheffield.ac.uk [ChELSI Institute, Department of Chemical and Biological Engineering, University of Sheffield, Sheffield S1 3JD (United Kingdom)

    2012-04-29

    Highlights: Black-Right-Pointing-Pointer FAs released from lipids form complex with Cu-TEA in chloroform. Black-Right-Pointing-Pointer The FA-Cu-TEA complex gives strong absorbance at 260 nm. Black-Right-Pointing-Pointer The absorbance is sensitive and independent of C-atom number in the FAs (10-18). Black-Right-Pointing-Pointer Microalgal lipid extract and pure FA (such as C16) can both be used as standards. - Abstract: Quantification of total lipids is a necessity for any study of lipid production by microalgae, especially given the current interest in microalgal carbon capture and biofuels. In this study, we employed a simple yet sensitive method to indirectly measure the lipids in microalgae by measuring the fatty acids (FA) after saponification. The fatty acids were reacted with triethanolamine-copper salts (TEA-Cu) and the ternary TEA-Cu-FA complex was detected at 260 nm using a UV-visible spectrometer without any colour developer. The results showed that this method could be used to analyse low levels of lipids in the range of nano-moles from as little as 1 mL of microalgal culture. Furthermore, the structure of the TEA-Cu-FA complex and related reaction process are proposed to better understand this assay. There is no special instrument required and the method is very reproducible. To the best of our knowledge, this is the first report of the use of UV absorbance of copper salts with FA as a method to estimate lipids in algal cultures. It will pave the way for a more convenient assay of lipids in microalgae and can readily be expanded for estimating lipids in other biological systems.

  8. A simple, reproducible and sensitive spectrophotometric method to estimate microalgal lipids

    International Nuclear Information System (INIS)

    Chen Yimin; Vaidyanathan, Seetharaman

    2012-01-01

    Highlights: ► FAs released from lipids form complex with Cu–TEA in chloroform. ► The FA–Cu–TEA complex gives strong absorbance at 260 nm. ► The absorbance is sensitive and independent of C-atom number in the FAs (10–18). ► Microalgal lipid extract and pure FA (such as C16) can both be used as standards. - Abstract: Quantification of total lipids is a necessity for any study of lipid production by microalgae, especially given the current interest in microalgal carbon capture and biofuels. In this study, we employed a simple yet sensitive method to indirectly measure the lipids in microalgae by measuring the fatty acids (FA) after saponification. The fatty acids were reacted with triethanolamine–copper salts (TEA–Cu) and the ternary TEA–Cu–FA complex was detected at 260 nm using a UV–visible spectrometer without any colour developer. The results showed that this method could be used to analyse low levels of lipids in the range of nano-moles from as little as 1 mL of microalgal culture. Furthermore, the structure of the TEA–Cu–FA complex and related reaction process are proposed to better understand this assay. There is no special instrument required and the method is very reproducible. To the best of our knowledge, this is the first report of the use of UV absorbance of copper salts with FA as a method to estimate lipids in algal cultures. It will pave the way for a more convenient assay of lipids in microalgae and can readily be expanded for estimating lipids in other biological systems.

  9. A Simple yet Accurate Method for Students to Determine Asteroid Rotation Periods from Fragmented Light Curve Data

    Science.gov (United States)

    Beare, R. A.

    2008-01-01

    Professional astronomers use specialized software not normally available to students to determine the rotation periods of asteroids from fragmented light curve data. This paper describes a simple yet accurate method based on Microsoft Excel[R] that enables students to find periods in asteroid light curve and other discontinuous time series data of…

  10. Simple method for quantification of gadolinium magnetic resonance imaging contrast agents using ESR spectroscopy.

    Science.gov (United States)

    Takeshita, Keizo; Kinoshita, Shota; Okazaki, Shoko

    2012-01-01

    To develop an estimation method of gadolinium magnetic resonance imaging (MRI) contrast agents, the effect of concentration of Gd compounds on the ESR spectrum of nitroxyl radical was examined. A solution of either 4-oxo-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPONE) or 4-hydroxy-2,2,6,6-tetramethylpiperidine-N-oxyl (TEMPOL) was mixed with a solution of Gd compound and the ESR spectrum was recorded. Increased concentration of gadolinium-diethylenetriamine pentaacetic acid chelate (Gd-DTPA), an MRI contrast agent, increased the peak-to-peak line widths of ESR spectra of the nitroxyl radicals, in accordance with a decrease of their signal heights. A linear relationship was observed between concentration of Gd-DTPA and line width of ESR signal, up to approximately 50 mmol/L Gd-DTPA, with a high correlation coefficient. Response of TEMPONE was 1.4-times higher than that of TEMPOL as evaluated from the slopes of the lines. The response was slightly different among Gd compounds; the slopes of calibration curves for acua[N,N-bis[2-[(carboxymethyl)[(methylcarbamoyl)methyl]amino]ethyl]glycinato(3-)]gadolinium hydrate (Gd-DTPA-BMA) (6.22 μT·L/mmol) and gadolinium-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid chelate (Gd-DOTA) (6.62 μT·L/mmol) were steeper than the slope for Gd-DTPA (5.45 μT·L/mmol), whereas the slope for gadolinium chloride (4.94 μT·L/mmol) was less steep than that for Gd-DTPA. This method is simple to apply. The results indicate that this method is useful for rough estimation of the concentration of Gd contrast agents if calibration is carried out with each standard compound. It was also found that the plot of the reciprocal square root of signal height against concentrations of contrast agents could be useful for the estimation if a constant volume of sample solution is taken and measured at the same position in the ESR cavity every time.

  11. Construction and testing of simple airfoils to demonstrate structural design, materials choice, and composite concepts

    Science.gov (United States)

    Bunnell, L. Roy; Piippo, Steven W.

    1993-01-01

    The objective of this educational exercise is to have students build and evaluate simple wing structures, and in doing so, learn about materials choices and lightweight construction methods. A list of equipment and supplies and the procedure for the experiment are presented.

  12. A simple Ultraviolet spectrophotometric method for the determination of etoricoxib in dosage formulations

    Directory of Open Access Journals (Sweden)

    Shipra Singh

    2012-01-01

    Full Text Available The present study was undertaken to develop a validated, rapid, simple, and low-cost ultraviolet (UV spectrophotometric method for estimating Etoricoxib (ETX in pharmaceutical formulations. The analysis was performed on λ max 233 nm using 0.1 M HCl as blank/diluent. The proposed method was validated on International Conference on Harmonization (ICH guidelines including parameters as linearity, accuracy, precision, reproducibility, and specificity. The proposed method was also used to access the content of the ETX in two commercial brands of Indian market. Beer′s law was obeyed in concentration range of 0.1-0.5 μg/ml, and the regression equation was Y = 0.418x + 0.018. The mean accuracy values for 0.1 μg/ml and 0.2 μg/ml concentration of ETX were found to be 99.76 ± 0.52% and 99.12 ± 0.84, respectively, and relative standard deviation (RSD of interday and intraday was less than 2%. The developed method was suitable and specific to the analysis of ETX even in the presence of common excipients. The method was applied on two different marketed brands and ETX contents were 98.5 ± 0.56 and 99.33 ± 0.44, respectively, of labeled claim. The proposed method was validated as per ICH guidelines and statistically good results were obtained. This method can be employed for routine analysis of ETX in bulk and commercial formulations.

  13. A simple Ultraviolet spectrophotometric method for the determination of etoricoxib in dosage formulations.

    Directory of Open Access Journals (Sweden)

    S Singh

    2012-01-01

    Full Text Available The present study was undertaken to develop a validated, rapid, simple, and low-cost ultraviolet (UV spectrophotometric method for estimating Etoricoxib (ETX in pharmaceutical formulations. The analysis was performed on Î max 233 nm using 0.1 M HCl as blank/diluent. The proposed method was validated on International Conference on Harmonization (ICH guidelines including parameters as linearity, accuracy, precision, reproducibility, and specificity. The proposed method was also used to access the content of the ETX in two commercial brands of Indian market. Beer′s law was obeyed in concentration range of 0.1-0.5 μg/ml, and the regression equation was Y = 0.418x + 0.018. The mean accuracy values for 0.1 μg/ml and 0.2 μg/ml concentration of ETX were found to be 99.76 ± 0.52% and 99.12 ± 0.84, respectively, and relative standard deviation (RSD of interday and intraday was less than 2%. The developed method was suitable and specific to the analysis of ETX even in the presence of common excipients. The method was applied on two different marketed brands and ETX contents were 98.5 ± 0.56 and 99.33 ± 0.44, respectively, of labeled claim. The proposed method was validated as per ICH guidelines and statistically good results were obtained. This method can be employed for routine analysis of ETX in bulk and commercial formulations.

  14. simple sequence repeat (SSR)

    African Journals Online (AJOL)

    In the present study, 78 mapped simple sequence repeat (SSR) markers representing 11 linkage groups of adzuki bean were evaluated for transferability to mungbean and related Vigna spp. 41 markers amplified characteristic bands in at least one Vigna species. The transferability percentage across the genotypes ranged ...

  15. A simple method for the determination of the specific activity of 125I-tracer used in radioimmunoassay

    International Nuclear Information System (INIS)

    Bhupal, V.; Mani, R.S.

    1986-01-01

    The specific activity of the 125 I-thyroxin used in thyroxin radioimmunoassay (RIA) was determined by a simple method involving combination of RIA and displacement analysis. It was compared with the value obtained by the conventional method based on radioiodination data. It is indicated that even for a non-protein hormone like thyroxin the specific activity of 125 I-thyroxin derived from iodination data is not reliable. The specific activites obtained by displacement analysis were consistent with the experimental findings. (author)

  16. Two simple cleanup methods combined with LC-MS/MS for quantification of steroid hormones in in vivo and in vitro assays

    DEFF Research Database (Denmark)

    Weisser, Johan Juhl; Hansen, Cecilie Hurup; Poulsen, Rikke

    2016-01-01

    Measuring both progestagens, androgens, corticosteroids as well as estrogens with a single method makes it possible to investigate the effects of endocrine-disrupting chemicals (EDCs) on the main pathways in the mammalian steroidogenesis. This paper presents two simple methods for the determination...... of the major steroid hormones in biological matrixes using liquid chromatography tandem mass spectrometry (LC-MS(2)). A novel method was developed for the determination of 14 steroids in the H295R in vitro assay without the need for solid phase extraction (SPE) purification prior to LC-MS(2) analysis....... The in vitro assay was validated by exposing H295R cells to prochloraz for inhibiting steroid hormone secretion and by exposing cells to forskolin for inducing steroid hormone secretion. The developed method fulfills the recommendations for the H295R assay suggested by the OECD. Furthermore, a simple off...

  17. Mechanical and Tribological Properties of PVD-Coated Cemented Carbide as Evaluated by a New Multipass Scratch-Testing Method

    Directory of Open Access Journals (Sweden)

    M. Fallqvist

    2012-01-01

    Full Text Available A new test method based on multipass scratch testing has been developed for evaluating the mechanical and tribological properties of thin, hard coatings. The proposed test method uses a pin-on-disc tribometer and during testing a Rockwell C diamond stylus is used as the “pin” and loaded against the rotating coated sample. The influence of normal load on the number of cycles to coating damage is investigated and the resulting coating damage mechanisms are evaluated by posttest scanning electron microscopy. The present study presents the test method by evaluating the performance of Ti0.86Si0.14N, Ti0.34Al0.66N, and (Al0.7Cr0.32O3 coatings deposited by cathodic arc evaporation on cemented carbide inserts. The results show that the test method is quick, simple, and reproducible and can preferably be used to obtain relevant data concerning the fatigue, wear, chipping, and spalling characteristics of different coating-substrate composites. The test method can be used as a virtually nondestructive test and, for example, be used to evaluate the fatigue and wear resistance as well as the cohesive and adhesive interfacial strength of coated cemented carbide inserts prior to cutting tests.

  18. A simple time-delayed method to control chaotic systems

    International Nuclear Information System (INIS)

    Chen Maoyin; Zhou Donghua; Shang Yun

    2004-01-01

    Based on the adaptive iterative learning strategy, a simple time-delayed controller is proposed to stabilize unstable periodic orbits (UPOs) embedded in chaotic attractors. This controller includes two parts: one is a linear feedback part; the other is an adaptive iterative learning estimation part. Theoretical analysis and numerical simulation show the effectiveness of this controller

  19. A simple component-connection method for building binary decision diagrams encoding a fault tree

    International Nuclear Information System (INIS)

    Way, Y.-S.; Hsia, D.-Y.

    2000-01-01

    A simple new method for building binary decision diagrams (BDDs) encoding a fault tree (FT) is provided in this study. We first decompose the FT into FT-components. Each of them is a single descendant (SD) gate-sequence. Following the node-connection rule, the BDD-component encoding an SD FT-component can each be found to be an SD node-sequence. By successively connecting the BDD-components one by one, the BDD for the entire FT is thus obtained. During the node-connection and component-connection, reduction rules might need to be applied. An example FT is used throughout the article to explain the procedure step by step. Our method proposed is a hybrid one for FT analysis. Some algorithms or techniques used in the conventional FT analysis or the newer BDD approach may be applied to our case; our ideas mentioned in the article might be referred by the two methods

  20. Experimental study on cascaded attitude angle control of a multi-rotor unmanned aerial vehicle with the simple internal model control method

    International Nuclear Information System (INIS)

    Song, Jun Beom; Byun, Young Seop; Jeong, Jin Seok; Kim, Jeong; Kang, Beom Soo

    2016-01-01

    This paper proposes a cascaded control structure and a method of practical application for attitude control of a multi-rotor Unmanned aerial vehicle (UAV). The cascade control, which has tighter control capability than a single-loop control, is rarely used in attitude control of a multi-rotor UAV due to the input-output relation, which is no longer simply a set-point to Euler angle response transfer function of a single-loop PID control, but there are multiply measured signals and interactive control loops that increase the complexity of evaluation in conventional way of design. However, it is proposed in this research a method that can optimize a cascade control with a primary and secondary loops and a PID controller for each loop. An investigation of currently available PID-tuning methods lead to selection of the Simple internal model control (SIMC) method, which is based on the Internal model control (IMC) and direct-synthesis method. Through the analysis and experiments, this research proposes a systematic procedure to implement a cascaded attitude controller, which includes the flight test, system identification and SIMC-based PID-tuning. The proposed method was validated successfully from multiple applications where the application to roll axis lead to a PID-PID cascade control, but the application to yaw axis lead to that of PID-PI

  1. Experimental study on cascaded attitude angle control of a multi-rotor unmanned aerial vehicle with the simple internal model control method

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jun Beom [Dept. of Aviation Maintenance, Dongwon Institute of Science and Technology, Yangsan (Korea, Republic of); Byun, Young Seop; Jeong, Jin Seok; Kim, Jeong; Kang, Beom Soo [Dept. of Aerospace Engineering, Pusan National University, Busan (Korea, Republic of)

    2016-11-15

    This paper proposes a cascaded control structure and a method of practical application for attitude control of a multi-rotor Unmanned aerial vehicle (UAV). The cascade control, which has tighter control capability than a single-loop control, is rarely used in attitude control of a multi-rotor UAV due to the input-output relation, which is no longer simply a set-point to Euler angle response transfer function of a single-loop PID control, but there are multiply measured signals and interactive control loops that increase the complexity of evaluation in conventional way of design. However, it is proposed in this research a method that can optimize a cascade control with a primary and secondary loops and a PID controller for each loop. An investigation of currently available PID-tuning methods lead to selection of the Simple internal model control (SIMC) method, which is based on the Internal model control (IMC) and direct-synthesis method. Through the analysis and experiments, this research proposes a systematic procedure to implement a cascaded attitude controller, which includes the flight test, system identification and SIMC-based PID-tuning. The proposed method was validated successfully from multiple applications where the application to roll axis lead to a PID-PID cascade control, but the application to yaw axis lead to that of PID-PI.

  2. A Simple and Efficient Numerical Method for Computing the Dynamics of Rotating Bose--Einstein Condensates via Rotating Lagrangian Coordinates

    KAUST Repository

    Bao, Weizhu; Marahrens, Daniel; Tang, Qinglin; Zhang, Yanzhi

    2013-01-01

    We propose a simple, efficient, and accurate numerical method for simulating the dynamics of rotating Bose-Einstein condensates (BECs) in a rotational frame with or without longrange dipole-dipole interaction (DDI). We begin with the three

  3. Linearized self-consistent quasiparticle GW method: Application to semiconductors and simple metals

    Science.gov (United States)

    Kutepov, A. L.; Oudovenko, V. S.; Kotliar, G.

    2017-10-01

    We present a code implementing the linearized quasiparticle self-consistent GW method (LQSGW) in the LAPW basis. Our approach is based on the linearization of the self-energy around zero frequency which differs it from the existing implementations of the QSGW method. The linearization allows us to use Matsubara frequencies instead of working on the real axis. This results in efficiency gains by switching to the imaginary time representation in the same way as in the space time method. The all electron LAPW basis set eliminates the need for pseudopotentials. We discuss the advantages of our approach, such as its N3 scaling with the system size N, as well as its shortcomings. We apply our approach to study the electronic properties of selected semiconductors, insulators, and simple metals and show that our code produces the results very close to the previously published QSGW data. Our implementation is a good platform for further many body diagrammatic resummations such as the vertex-corrected GW approach and the GW+DMFT method. Program Files doi:http://dx.doi.org/10.17632/cpchkfty4w.1 Licensing provisions: GNU General Public License Programming language: Fortran 90 External routines/libraries: BLAS, LAPACK, MPI (optional) Nature of problem: Direct implementation of the GW method scales as N4 with the system size, which quickly becomes prohibitively time consuming even in the modern computers. Solution method: We implemented the GW approach using a method that switches between real space and momentum space representations. Some operations are faster in real space, whereas others are more computationally efficient in the reciprocal space. This makes our approach scale as N3. Restrictions: The limiting factor is usually the memory available in a computer. Using 10 GB/core of memory allows us to study the systems up to 15 atoms per unit cell.

  4. Simple mathematical method to quantify p53 mutations in occupational lung cancer

    International Nuclear Information System (INIS)

    Helal, N.L.

    2005-01-01

    Radon-222, a decay product of uranium-238 and a source of high linear energy transfer (LET) alpha -particles, has been implicated in the increase risk of lung cancer in uranium miners as well as non-miners. The p53 gene mutational spectrum reveals evidence for a direct causal effect of radon inhalation in lung cancer. This mutation has been proposed as a marker of radon exposure. The development of such markers may ultimately be of benefit in the reduction of occupational morbidity and mortality from occupational cancer. One of the tasks in risk assessment of genotoxic occupational radiation exposure is to devise a simple numerical method. This method may be used to quantify the relationship between radiation dose and the effect on the genetic sequences. The tumor suppressor gene (TSG) p53 is an ideal bio marker addressing questions of exposure and risk. These proteins may be suitable for the design of more effective or less invasive cancer therapies. The clinical outcome of lung cancer patients may correlate with the normal regulation of these patients and, therefore, their identification may be used as a guideline for future therapy modalities. To investigate the association between radon exposure and p53 mutations in lung tumors, we have implied a mathematical method. This method has been developed from a 2-D graphical representational technique that enables easy visualization of base distributions. This is of special relevance to libraries of single nucleotide polymorphic (SNP) genes

  5. Simple formulae for interpretation of the dead time α (first moment) method of reactor noise

    International Nuclear Information System (INIS)

    Degweker, S.B.

    1999-01-01

    The Markov Chain approach for solving problems related to the presence of a non extending dead time in a particle counting circuit with time correlated pulses was developed in an earlier paper. The formalism was applied to, among others, the dead time α (first moment) method of reactor noise. For this problem, however the solution obtained was largely numerical in character and had a tendency to break down for systems close to criticality. In the present paper, simple analytical expressions are derived for the count rate and L ex , the quantities of interest in this method. Comparisons with Monte Carlo simulations show that these formulae are accurate in the range of system parameters of practical interest

  6. A simple method to identify areas of environmental risk due to manure application.

    Science.gov (United States)

    Flores, Héctor; Arumí, José Luis; Rivera, Diego; Lagos, L Octavio

    2012-06-01

    The management of swine manure is becoming an important environmental issue in Chile. One option for the final disposal of manure is to use it as a biofertilizer, but this practice could impact the surrounding environment. To assess the potential environmental impacts of the use of swine manure as a biofertilizer, we propose a method to identify zones of environmental risk through indices. The method considers two processes: nutrient runoff and solute leaching, and uses available information about soils, crops and management practices (irrigation, fertilization, and rotation). We applied the method to qualitatively assess the environmental risk associated with the use of swine manure as a biofertilizer in an 8,000-pig farm located in Central Chile. Results showed that the farm has a moderate environmental risk, but some specific locations have high environmental risks, especially those associated with impacts on areas surrounding water resources. This information could assist the definition of better farm-level management practices, as well as the preservation of riparian vegetation acting as buffer strips. The main advantage of our approach is that it combines qualitative and quantitative information, including particular situations or field features based on expert knowledge. The method is flexible, simple, and can be easily extended or adapted to other processes.

  7. A simple method for microtuber production in dioscorea opposita using single nodal segments

    International Nuclear Information System (INIS)

    Li, M.; Wang, Y; Liu, W.; Li, S.

    2015-01-01

    Dioscorea opposita Thunb. (Chinese yam) is an important tuber crop in East Asia because of its dual benefits edible and medicinal properties. Microtubers may provide a feasible alternative to in-vitro-grown plantlets as a means of micropropagation and a way to exchange healthy planting material. In this study, we have developed a simplified culture method for In vitro production of microtubers from D. opposita cv. Tiegun. In this method, microtubers formed in 98% of the internodes of single nodal segments after four weeks of dark-incubation when cultured in MS medium supplemented with 60 g sucrose 1-1 with shaking. Anatomical observations strongly supported the process of tuberization. We also found that 66% of the microtubers produced In vitro sprouted two months after transfer to vermiculite. The protocol presented here provides a simple model for studying the physiological, biochemical, and molecular mechanisms of tuberization in D. opposita, and shows good potential for large-scale production of microtubers as well. (author)

  8. A simple method to impose rotations and concentrated moments on ANC beams

    International Nuclear Information System (INIS)

    Romero, Ignacio; Arribas, Juan J.

    2009-01-01

    Recently introduced ANC beam elements furnish a simple formulation that allows to solve nonlinear problems of beams, including those with large displacements and strains, as well as complex nonlinear (inelastic) materials. The success and simplicity of these finite elements is mainly due to the fact that the only nodal degrees of freedom that they employ are displacements, and rotations are thus completely avoided. This in turn makes it very difficult to apply concentrated moments or to impose rotations at specific nodes of a finite element mesh. In this article, we present a simple enhancement to this beam formulation that allows to apply these two types of boundary conditions in a simple manner, making ANC beam elements more versatile for both multibody and structural applications

  9. "System evaluates system": method for evaluating the efficiency of IS

    Directory of Open Access Journals (Sweden)

    Dita Blazkova

    2016-10-01

    Full Text Available In paper I deal with the possible solution of evaluating the efficiency of information systems in companies. The large number of existing methods used to address the efficiency of information systems is dependent on the subjective responses of the user that may distort output evaluation. Therefore, I propose a method that eliminates the subjective opinion of a user as the primary data source. Applications, which I suggests as part of the method, collects relevant data. In this paper I describe the application in detail. This is a follow-on program on any system that runs parallel with it. The program automatically collects data for evaluation. Data include mainly time data, positions the mouse cursor, printScreens, i-grams of previous, etc. I propose a method of evaluation of the data, which identifies the degree of the friendliness of the information system to the user. Thus, the output of the method is the conclusion whether users, who work with the information system, can handle effectively work with it.

  10. Echocardiographic evaluation of simple versus complex congenital heart disease in a tertiary care Paediatrics Hospital

    OpenAIRE

    Uttam Kumar Sarkar; Anish Chatterjee; Suprit Basu; Atanu Pan; Sumit Periwal

    2017-01-01

    Background & Objectives:Congenital heart diseases are treatable either by catheter based intervention or open heart surgery according to their quality. In our study we aim to analyze congenital heart disease echocardiographically into simple versus complex heart disease at a tertiary care centre with a public health planning and policy making perspective.Materials & Methods:This hospital based study was done on 1010 patients, both from in-patient and out-patient, who were clinically s...

  11. Classes evaluation: Methods and tools

    Directory of Open Access Journals (Sweden)

    Grabiński Tadeusz

    2013-01-01

    Full Text Available This study presents a method, tools, course and results of foreign language classes evaluation conducted in the summer semester 2012/2013 in the Andrzej Frycz - Modrzewski Krakow University. Because a new evaluation procedure has been implemented at the University, the former method - based on paper forms filled in by the students - was abandoned. On the surveyanyplace.com website, a free account has been registered and the form of the evaluation questionnaire has been inserted. This coverage presents results of a taxometric analysis aimed at checking the degree of mutual correspondence (correlation between certain criteria and instancing a graphic presentation of the evaluation results in a multidimensional perspective. In order to classify the grading criteria, the Ward's agglomerative method, along with Euclidean metric as a measure of criteria similarity, have been used. Calculations have been made with the use of Statistica package. Results of the questionnaire show that foreign language teaching at the Andrzej Frycz Modrzewski Krakow University is conducted professionally and on a high factual level.

  12. Simple method for the calculation and use of CVD phase diagrams with applications to the Ti-B-Cl-H system, 1200 to 8000K

    International Nuclear Information System (INIS)

    Randich, E.; Gerlach, T.M.

    1980-03-01

    A simple method for calculating multi-component gas-solid equilibrium phase diagrams for chemical vapor deposition (CVD) systems is presented. The method proceeds in three steps: dtermination of stable solid assemblages, evaluation of gas-solid stability relations, and calcuation of conventional phase diagrams using a new free energy minimization technique. The phase diagrams can be used to determine (1) bulk compositions and phase fields accessible by CVD techniques; (2) expected condensed phases for various starting gas mixtures; and (3) maximum equilibrium yields for specific CVD process variables. The three step thermodynamic method is used to calcuate phase diagrams for the example CVD system Ti-B-Cl-H at 1200 and 800 0 K. Examples of applications of the diagrams for yield optimization and experimental accessibility studies are presented and discussed. Experimental verification of the TiB 2 + Gas/Gas phase field boundary at 1200 0 K, H/Cl = 1 confirms the calculated boundary and indicates that equilibrium is nearly and rapidly approached under laboratory conditions

  13. A simple and fast detection method for bovine milk residues in foods: a 2-site monoclonal antibody immunochromatography assay.

    Science.gov (United States)

    Xuli, Wu; Weiyi, He; Ji, Kunmei; Wenpu, Wan; Dongsheng, Hu; Hui, Wu; Xinpin, Luo; Zhigang, Liu

    2013-03-01

    The ingredient declaration on food labels assumes paramount importance in the protection of food-allergic consumers. China has not implemented Food allergen labeling. A gold immunochromatography assay (GICA) was developed using 2 monoclonal antibodies (mAb) against the milk allergen β-lactoglobulin in this study. The GICA was specific for pure milk samples with a sensitivity of 0.2 ng/mL. Milk protein traces extracted from 110 food products were detected by this method. The labels of 106 were confirmed by our GICA method: 57 food samples originally labeled as containing milk were positive for β-lactoglobulin and 49 food samples labeled as not containing milk were negative for β-lactoglobulin. However, 3 food samples falsely labeled as containing milk were found to contain no β-lactoglobulin whereas 1 food sample labeled as not containing milk actually contained β-lactoglobulin. First, these negatives could be because of the addition of a casein fraction. Second, some countries demand that food manufacturers label all ingredients derived from milk as "containing milk" even though the ingredients contain no detectable milk protein by any method. Our GICA method could thus provide a fast and simple method for semiquantitatation of β-lactoglobulin in foods. The present method provides a fast, simple, semiquantitative method for the determination of milk allergens in foods. © 2013 Institute of Food Technologists®

  14. A simple theoretical extension to the analysis of photothermal deflection signal for low thermal diffusivity evaluation

    International Nuclear Information System (INIS)

    Ravi, Jyotsna; Lekshmi, S.; Nair, K.P.R.; Rasheed, T.M.A

    2004-01-01

    A modified amplitude method to analyze the photothermal probe beam deflection signal for the determination of low thermal diffusivity values of materials is proposed. This simple theoretical model, which is an extension of the amplitude method proposed by Quelin et al., takes into account the dependence of the photothermal signal on the height of the probe beam above the sample surface which affects mirage measurements when the thermal diffusivity of the coupling medium is greater than that of the sample. The present work is similar to the modification to the phase method proposed by Bertolotti et al. for determination of low thermal diffusivity. The method can be applied irrespective of whether the sample is optically transparent or optically opaque and is independent of thickness

  15. A simple method for determining the activity of large-area beta sources constructed from anodized aluminum foils

    International Nuclear Information System (INIS)

    Stanga, D.

    2014-01-01

    A simple method has been developed for determining the activity of large-area beta reference sources in anodized aluminum foils. It is based on the modeling of the transmission of beta rays through thin foils in planar geometry using Monte Carlo simulation. The method was checked experimentally and measurement results show that the activity of large-area beta reference sources in anodized aluminum foils can be measured with standard uncertainties smaller than the limit of 10% required by ISO 8769. - Highlights: • A method for determining the activity of large-area beta sources is presented. • The method is based on a model of electron transport in planar geometry. • The method makes use of linear programming for determining the activity. • The uncertainty of the method is smaller than 10%

  16. Variability in clinical data is often more useful than the mean: illustration of concept and simple methods of assessment

    NARCIS (Netherlands)

    Zwinderman, A. H.; Cleophas, T. J.

    2005-01-01

    BACKGROUND: Clinical investigators, although they are generally familiar with testing differences between averages, have difficulty testing differences between variabilities. OBJECTIVE: To give examples of situations where variability is more relevant than averages and to describe simple methods for

  17. Double sampling with multiple imputation to answer large sample meta-research questions: Introduction and illustration by evaluating adherence to two simple CONSORT guidelines

    Directory of Open Access Journals (Sweden)

    Patrice L. Capers

    2015-03-01

    Full Text Available BACKGROUND: Meta-research can involve manual retrieval and evaluation of research, which is resource intensive. Creation of high throughput methods (e.g., search heuristics, crowdsourcing has improved feasibility of large meta-research questions, but possibly at the cost of accuracy. OBJECTIVE: To evaluate the use of double sampling combined with multiple imputation (DS+MI to address meta-research questions, using as an example adherence of PubMed entries to two simple Consolidated Standards of Reporting Trials (CONSORT guidelines for titles and abstracts. METHODS: For the DS large sample, we retrieved all PubMed entries satisfying the filters: RCT; human; abstract available; and English language (n=322,107. For the DS subsample, we randomly sampled 500 entries from the large sample. The large sample was evaluated with a lower rigor, higher throughput (RLOTHI method using search heuristics, while the subsample was evaluated using a higher rigor, lower throughput (RHITLO human rating method. Multiple imputation of the missing-completely-at-random RHITLO data for the large sample was informed by: RHITLO data from the subsample; RLOTHI data from the large sample; whether a study was an RCT; and country and year of publication. RESULTS: The RHITLO and RLOTHI methods in the subsample largely agreed (phi coefficients: title=1.00, abstract=0.92. Compliance with abstract and title criteria has increased over time, with non-US countries improving more rapidly. DS+MI logistic regression estimates were more precise than subsample estimates (e.g., 95% CI for change in title and abstract compliance by Year: subsample RHITLO 1.050-1.174 vs. DS+MI 1.082-1.151. As evidence of improved accuracy, DS+MI coefficient estimates were closer to RHITLO than the large sample RLOTHI. CONCLUSIONS: Our results support our hypothesis that DS+MI would result in improved precision and accuracy. This method is flexible and may provide a practical way to examine large corpora of

  18. A simple dissolved metals mixing method to produce high-purity MgTiO3 nanocrystals

    International Nuclear Information System (INIS)

    Pratapa, Suminar; Baqiya, Malik A.; Istianah,; Lestari, Rina; Angela, Riyan

    2014-01-01

    A simple dissolved metals mixing method has been effectively used to produce high-purity MgTiO 3 (MT) nanocrystals. The method involves the mixing of independently dissolved magnesium and titanium metal powders in hydrochloric acid followed by calcination. The phase purity and nanocrystallinity were determined by making use of laboratory x-ray diffraction data, to which Rietveld-based analyses were performed. Results showed that the method yielded only one type magnesium titanate powders, i.e. MgTiO 3 , with no Mg 2 TiO 4 or MgTi 2 O 5 phases. The presence of residual rutile or periclase was controlled by adding excessive Mg up to 5% (mol) in the stoichiometric mixing. The method also resulted in MT nanocrystals with estimated average crystallite size of 76±2 nm after calcination at 600°C and 150±4 nm (at 800°C). A transmission electron micrograph confirmed the formation of the nanocrystallites

  19. Methods for estimating wake flow and effluent dispersion near simple block-like buildings

    International Nuclear Information System (INIS)

    Hosker, R.P. Jr.

    1981-05-01

    This report is intended as an interim guide for those who routinely face air quality problems associated with near-building exhaust stack placement and height, and the resulting concentration patterns. Available data and methods for estimating wake flow and effluent dispersion near isolated block-like structures are consolidated. The near-building and wake flows are described, and quantitative estimates for frontal eddy size, height and extent of roof and wake cavities, and far wake behavior are provided. Concentration calculation methods for upwind, near-building, and downwind pollutant sources are given. For an upwind source, it is possible to estimate the required stack height, and to place upper limits on the likely near-building concentration. The influences of near-building source location and characteristics relative to the building geometry and orientation are considered. Methods to estimate effective stack height, upper limits for concentration due to flush roof vents, and the effect of changes in rooftop stack height are summarized. Current wake and wake cavity models are presented. Numerous graphs of important expressions have been prepared to facilitate computations and quick estimates of flow patterns and concentration levels for specific simple buildings. Detailed recommendations for additional work are given

  20. A simple and rapid method for high-resolution visualization of single-ion tracks

    Directory of Open Access Journals (Sweden)

    Masaaki Omichi

    2014-11-01

    Full Text Available Prompt determination of spatial points of single-ion tracks plays a key role in high-energy particle induced-cancer therapy and gene/plant mutations. In this study, a simple method for the high-resolution visualization of single-ion tracks without etching was developed through the use of polyacrylic acid (PAA-N, N’-methylene bisacrylamide (MBAAm blend films. One of the steps of the proposed method includes exposure of the irradiated films to water vapor for several minutes. Water vapor was found to promote the cross-linking reaction of PAA and MBAAm to form a bulky cross-linked structure; the ion-track scars were detectable at a nanometer scale by atomic force microscopy. This study demonstrated that each scar is easily distinguishable, and the amount of generated radicals of the ion tracks can be estimated by measuring the height of the scars, even in highly dense ion tracks. This method is suitable for the visualization of the penumbra region in a single-ion track with a high spatial resolution of 50 nm, which is sufficiently small to confirm that a single ion hits a cell nucleus with a size ranging between 5 and 20 μm.