  1. Dosimetry of a silicone breast prosthesis

    International Nuclear Information System (INIS)

    McGinley, P.H.; Powell, W.R.; Bostwick, J.

    1980-01-01

    Dose measurements were conducted in a phantom which simulates breast tissue and in another phantom which simulates a breast containing a silicone prosthesis. No detectable difference was found when the irradiations were carried out with tangential beams of 60 Co radiation. The degree of backscatter and absorption of radiation by the prosthesis and phantom were also similar. A slight decrease in dose of approximately 8% was found at the interface between the prosthesis and muscle-equivalent material

  2. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    International Nuclear Information System (INIS)

    Krishnan, L.; St George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9-20 MeV electron beams and 1.25-15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prosthesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations

  3. Effect of silicone gel breast prosthesis on electron and photon dose distributions

    International Nuclear Information System (INIS)

    Krishnan, L.; St George, F.J.; Mansfield, C.M.; Krishnan, E.C.

    1983-01-01

    The effect of a silicone gel breast prosthesis on the absorbed dose distribution of 9--20 MeV electron beams and 1.25--15 MV photon beams was studied. Compared to water measurements, at depths smaller than the practical range of the electron beams, the central axis depth dose values below the prothesis were lower for all energies by as much as 3.5%. However, at depths near the practical range, the central axis depth dose values for the prosthesis were greater than that of water by as much as 33%. Since this occurs near the end of the electron range, the resultant difference may not be clinically significant. Results of the effect of breast prosthesis on photon depth dose distributions reveal that no clinically significant perturbation is produced by the breast prosthesis using Co-60, 6- and 15-MV radiations

  4. Effect of breast augmentation after breast-conserving surgery for breast cancer on radiation dose. Silicone prosthesis and changes in radiation dose

    International Nuclear Information System (INIS)

    Tonari, Ayako; Nako, Yasunobu; Ikezaki, Hiromi; Maruyama, Yasushi; Ikeda, Ikuo; Kusuda, Junko; Harii, Kiyonori; Takayama, Makoto

    2008-01-01

    The results of a study simulating postoperative radiation therapy of remaining breast tissue with a silicone bag prosthesis implanted to examine the effects of the prosthesis on radiation dosage and surrounding tissue are reported. The evaluation was conducted in two stages: a water phantom was used to evaluate scattering effects of a prosthesis installed inside the phantom using glass rod detector (GRD) set around the prosthesis. Measurements were conducted on both entrance and rear sides of the prosthesis. A Rand phantom was used to measure radiation doses around the prosthesis. The first evaluation resulted in a less than 5.4% reduction in dose at the rear side of the prosthesis whereas the second evaluation, for opposing portal irradiation used with breast-conserving surgical treatment, showed the effects of the prosthesis on radiation dosage being within ±2%, the permitted treatment range. In conclusion, for treating breast cancer, combining surgical treatment of the cancer with implanting of prosthesis for breast reconstruction followed by radiation treatment appears feasible as no effects on dosage were observed on treatment effectiveness. (author)

  5. Pattern of External Breast Prosthesis Use by Post Mastectomy Breast Cancer Patients in India: Descriptive Study from Tertiary Care Centre.

    Science.gov (United States)

    Ramu, D; Ramesh, Rakesh S; Manjunath, Suraj; Shivakumar; Goel, Vipin; Hemnath, G N; Alexander, Annie

    2015-12-01

    In India, Breast cancer is now the most common cancer in urban and 2nd most common in rural areas [1]. The incidence is rising, more younger women are getting affected and due to increase in survival rates there is an increase in the total number of women suffering from breast Cancer. So far there are no studies evaluating the pattern of breast prosthesis use in Indian scenario. The aim of this study is to address the patterns of external breast prosthesis used in India and view of Indian women on such prosthesis after mastectomy for breast cancer. This was a descriptive longitudinal study. In this study we interviewed (telephonic) 63 people, after three years of completing treatment under The Department of Surgical Oncology, St. Johns medical college, Bangalore. Among the study group, 27 members (40 %) were using various prosthesis, rest 36 women were not using any type of prosthesis. Among the users of prosthesis, silicon prosthesis was used by 6 women, padded cups by 8 women, cloth or cotton by 12 women and 1 woman used other type of prosthesis. Most women use simple items like cloth and cotton (44 %). Next most commonly used prosthesis are padded cups(). Only 22 % of women were found using silicon prosthesis in this study. Most of the well educated patients used external prosthesis either in the form of silicon prosthesis or padded cups. Most of women below age of 50 used external breast prosthesis. Use of prosthesis was more in urban compared to rural population (48 % vs 25 %). Prosthesis users worried more about the body image than women not using prosthesis. 25 % of women using prosthesis had body image issues where as only 5 % of non prosthesis users had such problems. Prosthesis users need improvement in terms of comfort, size, shape and affordability. Most common reasons for not using prosthesis are age, lack of motivation and awareness. Less than half of the women included in this study used external prosthesis after mastectomy for breast cancer

  6. Presentation of Apocrine Breast Carcinoma in a Woman with Bilateral Silicone Prosthesis; Presentacion de un carcinoma apocrino de mama en una mujer con protesis bilateral de silicona

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, J. A.; Salvador, R.; Salvador, M.; Barranco, C.

    2003-07-01

    We present a case of apocrine breast carcinoma in a 45 year-old woman with bilateral silicone breast prosthesis whose clinical manifestations and mammography were that of a palpable nodule-high glandular density, rounded and with imprecise borders devoid of any visible microcalcifications. A bibliographical revision confirmed the infrequent association of this type of tumor with the presence of silicone breast implants, precisely in which we consider its radiological interest to lie. (Author) 11 refs.

  7. Electron beam irradiation after reconstruction with silicone gel implant in breast cancer

    International Nuclear Information System (INIS)

    Krishnan, L.; Krishnan, E.C.

    1986-01-01

    Irradiation for breast cancer in the presence of a silicone gel breast prosthesis is sometimes necessary. There is a concern among radiation and other oncologists as to whether the presence of the prosthetic implant would interfere with delivery of the needed irradiation doses. Electron beams, with their finite penetration and rapid fall-off, offer a mode of adequately treating the recurrence and minimizing the radiation to the underlying normal structures, such as the lung and the heart. The dose distribution using 9-20 MeV electrons in the presence of a breast prosthesis is compared to the dose distribution without the implant in a tissue equivalent water phantom. The results reveal no significant difference in the dose delivered due to the presence of the prosthesis. Clinical verification of the dosimetry in the presence of the prosthesis confirmed that the presence of the silicone gel implant does not compromise treatment by irradiation in the management of breast cancer

  8. Breast cancer in a patient with silicone breast implants after 13 years.

    Science.gov (United States)

    Bingham, H G; Copeland, E M; Hackett, R; Caffee, H H

    1988-03-01

    The patient described in this article is a 45-year-old woman who developed an infiltrating ductal carcinoma in her left breast next to a Silastic mammary implant that had been used for augmentation some 13 years previously. She underwent a modified radical mastectomy and removal of the silicone prosthesis with an axillary lymph node dissection. Twenty-six axillary lymph nodes were negative for metastatic disease. The 165-gram silicone gel prosthesis was surrounded by a thin fibrous capsule with an attached 1-cm carcinoma that did not invade the fibrous capsule. It appeared that the capsule presented a barrier to the invading ductal carcinoma. The fibrous capsule surrounding the Silastic implant may have altered the spread of the breast cancer without being related to its genesis.

  9. The Effect of Breast Reconstruction Prosthesis on Photon Dose Distribution in Breast Cancer Radiotherapy

    Directory of Open Access Journals (Sweden)

    fatemeh sari

    2017-12-01

    Full Text Available Introduction: Siliconeprosthetic implants are commonlyutilizedfor tissue replacement and breast augmentation after mastectomy. On the other hand, some patients require adjuvant radiotherapy in order to preventlocal-regional recurrence and increment ofthe overall survival. In case of recurrence, the radiation oncologist might have to irradiate the prosthesis.The aim of this study was to evaluate the effect of silicone prosthesis on photon dose distribution in breast radiotherapy. Materials and Methods: The experimental dosimetry was performed using theprosthetic breast phantom and the female-equivalent mathematical chest phantom. A Computerized Tomographybased treatment planning was performedusing a phantom and by CorePlan Treatment Planning System (TPS. For measuring the absorbed dose, thermoluminescent dosimeter(TLD chips (GR-207A were used. Multiple irradiations were completed for all the TLD positions, and the dose absorbed by the TLDs was read by a lighttelemetry (LTM reader. Results: Statistical comparisons were performed between the absorbed dosesassessed by the TLDs and the TPS calculations forthe same sites. Our initial resultsdemonstratedanacceptable agreement (P=0.064 between the treatment planning data and the measurements. The mean difference between the TPS and TLD resultswas 1.99%.The obtained findings showed that radiotherapy is compatible withsilicone gel prosthesis. Conclusion: It could be concludedthat the siliconbreast prosthesis has no clinicallysignificant effectondistribution of a 6 MV photon beam for reconstructed breasts.

  10. Magnetically retained silicone facial prosthesis

    African Journals Online (AJOL)

    2013-06-09

    Jun 9, 2013 ... Prosthetic camouflaging of facial defects and use of silicone maxillofacial material are the alternatives to the surgical retreatment. Silicone elastomers provide more options to clinician for customization of the facial prosthesis which is simple, esthetically good when coupled with bio magnets for retention.

  11. Radiological and echographic aspects of breasts with silicone implants; Aspectos radiologicos e ecograficos das mamas com protese de silicone

    Energy Technology Data Exchange (ETDEWEB)

    Pace Bauab, S de [Instituto de Radiodiagnostico Rio Preto, Sao Jose do Rio Preto, SP (Brazil)

    1994-10-01

    The silicone prosthesis, its application in breast augmentation mammoplasty and the studies about its association with auto-immune diseases and cancer, are commented. The normal and the pathologic radiologic and echographic aspects of breasts with implants are discussed, concerning to the prosthesis itself and to the adjacent parenchyma. The validity of mammographic and ultrasound mammography in the detection of cancer and of alterations of the implants are emphasized and also the importance of exams of high technical quality.(author). 16 refs, 13 figs.

  12. Malrotation of the McGhan Style 510 prosthesis.

    NARCIS (Netherlands)

    Schots, J.M.; Fechner, M.R.; Hoogbergen, M.M.; Tits, H.W.H.J.

    2010-01-01

    BACKGROUND: Anatomically shaped cohesive silicone breast implants are frequently used in aesthetic and reconstructive surgery. After successful results with the Style 410 prosthesis, McGhan (Natrelle, Allergan) introduced the Style 510 prosthesis. After using this novel prosthesis, the authors

  13. Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis.

    Science.gov (United States)

    Buzayan, Muaiyed M

    2014-02-01

    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication. To provide an aesthetic and stable facial prosthesis, the extra-oral prosthesis was fabricated using silicone material, while the intra-oral defect was restored with obturator prosthesis, and then both prostheses were connected and attached to each other using magnets. This clinical report describes the rehabilitation of a large mid-facial defect with a two-piece prosthesis. The silicone facial prosthesis was made hollow and lighter by using an acrylic framework. Two acrylic channels were included within the facial prosthesis to provide the patient with clean and patent airways. A sectional mid-facial prosthesis was made and retained in place by using magnets, which resulted in a significant improvement in the aesthetical and functional outcome without the need for plastic surgery. Silicone prostheses are reliable alternatives to surgery and should be considered in selected cases.

  14. Rehabilitation of amputed thumb with a silicone prosthesis

    OpenAIRE

    Asnani, Pooja; Shivalingappa, Chandu Giriyapura; Mishra, Sunil Kumar; Somkuwar, Kirti; Khan, Faisal

    2015-01-01

    Creating prosthesis, having realistic skin surface and seamless visual integration with the surrounding tissues, requires both artistic and technical skill. Anatomical design, thin margins, lifelike fingernails and realistic color/contours are essential for patient satisfaction. Prosthesis is especially useful in case of lost body parts, as reconstructive surgery cannot fully restore aesthetics. This case report describes a simple technique for fabricating silicon finger prosthesis for a pati...

  15. Custom-made silicone hand prosthesis: A case study.

    Science.gov (United States)

    Nayak, S; Lenka, P K; Equebal, A; Biswas, A

    2016-09-01

    Up to now, a cosmetic glove was the most common method for managing transmetacarpal (TMC) and carpometacarpal (CMC) amputations, but it is devoid of markings and body color. At this amputation level, it is very difficult to fit a functional prosthesis because of the short available length, unsightly shape, grafted skin, contracture and lack of functional prosthetic options. A 30-year-old male came to our clinic with amputation at the 1st to 4th carpometacarpal level and a 5th metacarpal that was projected laterally and fused with the carpal bone. The stump had grafted skin, redness, and an unhealed suture line. He complained of pain projected over the metacarpal and suture area. The clinical team members decided to fabricate a custom-made silicone hand prosthesis to accommodate the stump, protect the grafted skin, improve the hand's appearance and provide some passive function. The custom silicone hand prosthesis was fabricated with modified flexible wires to provide passive interphalangeal movement. Basic training, care and maintenance instructions for the prosthesis were given to the patient. The silicone hand prosthesis was able to restore the appearance of the lost digits and provide some passive function. His pain (VAS score) was reduced. Improvement in activities of daily living was found in the DASH questionnaire and Jebsen-Taylor Hand Function test. A silicone glove is a good option for more distal amputations, as it can accommodate any deformity, protect the skin, enhance the appearance and provide functional assistance. This case study provides a simple method to get passively movable fingers after proximal hand amputation. Copyright © 2016. Published by Elsevier Masson SAS.

  16. Case Report: Magnetically retained silicone facial prosthesis ...

    African Journals Online (AJOL)

    Prosthetic camouflaging of facial defects and use of silicone maxillofacial material are the alternatives to the surgical retreatment. Silicone elastomers provide more options to clinician for customization of the facial prosthesis which is simple, esthetically good when coupled with bio magnets for retention. Key words: Magnet ...

  17. Rupture of an expander prosthesis mimics axillary cancer recurrence.

    LENUS (Irish Health Repository)

    Ismael, T

    2005-10-01

    Regional silicone gel migration from a ruptured breast implant has been reported at different locations including the upper extremity, chest wall muscles, axilla and back. We report a patient who presented with an axillary mass that mimicked a regional recurrence 5 years after breast cancer reconstruction with a latissimus dorsi musculocutaneous flap and silicon gel expander-prosthesis. Surgical exploration revealed that the mass contained silicone gel around the port of the breast expander that had ruptured. The mass was confluent with an intracapsular silicone leak through a tract along the tube of the expander port.

  18. Breast Prothesis Leakage and Malignant Changes of the Breast

    OpenAIRE

    Al-Lawati, Taha; Kutty, Rajyashree

    2009-01-01

    A breast implant is a prosthesis used to enhance the size of a woman’s breasts. Silicon implants are most commonly used, but as with all surgical implants it has some complications. The question is whether it can induce breast cancer? During the last year, a case of reconstructed breast with prosthesis which leaked was presented. The aim of this report is to review current literature to evaluate whether there are reported correlations between breast cancer and breast implants. The conclusion ...

  19. Axillary silicone lymphadenopathy presenting with a lump and altered sensation in the breast: a case report

    Directory of Open Access Journals (Sweden)

    Adams Simon T

    2009-03-01

    Full Text Available Abstract Introduction Silicone lymphadenopathy is a rare but recognised complication of procedures involving the use of silicone. It has a poorly understood mechanism but is thought to occur following the transportation of silicone particles from silicone-containing prostheses to lymph nodes by macrophages. Case presentation We report of a case involving a 35-year-old woman who presented to the breast clinic with a breast lump and altered sensation below her left nipple 5 years after bilateral cosmetic breast augmentations. A small lump was detected inferior to the nipple but clinical examination and initial ultrasound investigation showed both implants to be intact. However, mammography and magnetic resonance imaging of both breasts revealed both intracapsular and extracapsular rupture of the left breast prosthesis. The patient went on to develop a flu-like illness and tender lumps in the left axilla and right mastoid regions. An excision biopsy of the left axillary lesion and replacement of the ruptured implant was performed. Subsequent histological analysis showed that the axillary lump was a lymph node containing large amounts of silicone. Conclusion The exclusion of malignancy remains the priority when dealing with lumps in the breast or axilla. Silicone lymphadenopathy should however be considered as a differential diagnosis in patients in whom silicone prostheses are present.

  20. Osseointegrated silicone finger prosthesis using dental implants: a renovated technique.

    Science.gov (United States)

    Vinnakota, Dileep Nag; Sankar, V Vijay; Chirumamilla, Naveen; Reddy, V Vamsikrishna

    2014-11-01

    In clinical practice, we come across patients with traumatically amputated or congenitally missing partial or complete fingers that can be restored using microsurgical replantation or transplantation procedures. However, in some cases this might not be possible due to systemic or local factors and the lost or missing part has to be replaced prosthetically to offer psychological and functional wellbeing. These prostheses can be constructed with various materials like acrylics or silicone retained with the help of auxiliary aids. However, these prostheses cause some hindrance in performing functions like writing, typing, etc. The aim of the present trial was to ameliorate the existing design of implant supported finger prosthesis. Distal phalange of middle finger replaced with implant supported silicone finger prosthesis is modified by utilizing a metal framework to support silicone material to improve rigidity while working. We could achieve a good function, esthetics and tactile sensibility with this modified design. Whenever, feasible this design can improve the performance and patients feel a deep sense of satisfaction and improved self-esteem with this modified prosthesis.

  1. Rehabilitation of single finger amputation with customized silicone prosthesis

    OpenAIRE

    Yadav, Niharika; Chand, Pooran; Jurel, Sunit Kumar

    2016-01-01

    Finger amputations are common in accidents at home, work, and play. Apart from trauma, congenital disease and deformity also leads to finger amputation. This results in loss of function, loss of sensation as well as loss of body image. Finger prosthesis offers psychological support and social acceptance in such cases. This clinical report describes a method to fabricate ring retained silicone finger prosthesis in a patient with partial finger loss.

  2. Prosthetic management of mid-facial defect with magnet-retained silicone prosthesis

    OpenAIRE

    Buzayan, M. M.

    2014-01-01

    Background and aim: Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication. Technique: To provide an aesthetic and stable facial...

  3. A Biomimetic Approach for Designing a Full External Breast Prosthesis: Post-Mastectomy

    Directory of Open Access Journals (Sweden)

    Pedro Cruz

    2018-03-01

    Full Text Available This work presents the design of a new breast prosthesis using the biomimetic technique for cases of complete mastectomy to address the problem of the increasing number of women diagnosed with breast cancer in Mexico who are candidates for a mastectomy. The designed prosthesis considers the morphology of a real breast regarding its internal structure to obtain authentic mobility and feel. In order to accomplish this, a model was obtained in 3D CAD using a coordinate measuring machine (CMM that can be scalable without losing its qualities, and which can be used in any type of patient; afterwards, a finite element model was developed and a static analysis performed with suggested load cases to evaluate the sensitivity and naturalness of the prosthesis; and finally, a modal analysis was conducted. The results obtained in displacements and in distribution of stress for the load cases assessed are consistent with those of a real breast: there were smooth contours and there was natural mobility in the prosthesis designed by means of the biomimetic technique.

  4. [Silicone breast prosthesis and rheumatoid arthritis: a new systemic disease: siliconosis. A case report and a critical review of the literature].

    Science.gov (United States)

    Iannello, S; Belfiore, F

    1998-04-01

    Today the number of women receiving breast implants of silicone gel, for augmentation or reconstruction of the breast, is increasing. Silicon implants may cause local complications (such as capsular contracture, rupture, closed capsulotomy, gel "bleed", nodular foreign body granulomas in the capsular tissue and lymph nodes) or general symptoms. An adverse immune reaction with signs and symptoms of rheumatoid disorders is also possible, although an increased frequency of true autoimmune systemic connective tissue diseases is controversial. The US Food and Drug Administration advised that these silicone implants should be used only in reconstructive surgery and as part of clinical trials. Silicone is not an inert substance and silicone compounds were found in the blood and liver of women with silicone breast implants. The development of disease related to silicone implants would depend on genetic factors, so that only a very few women are potentially at risk. HLA-DR53 may be a marker of predisposed subjects. Breast-feeding by women with silicone implants should not be recommended for possible autoimmune disorders in the children. We report the case of an adult female patient with silicone breast implantation for bilateral mastectomy (performed 12 months before) and a unique syndrome characterized by low-grade fever, chronic fatigue, arthralgias of the hands, dysphagia, dry eye, increased level of rheumatoid factor and decreased value of complement C3 and C4. No increased erythrocyte sedimentation rate occurred, and no ANA, nDNA, ENA and AAT autoantibodies were evidence. A critical review of literature (source: MEDLINE 1980-1997) was performed and our case seems to be the first one reported in Italy. The internist should become familiar with the immunological disorders related to silicone breast implants, often so marked to require the explantation of the prostheses to improve symptomatology. However, perhaps due to the leak and spreading of silicone, the progression

  5. Pattern of External Breast Prosthesis Use by Post Mastectomy Breast Cancer Patients in India: Descriptive Study from Tertiary Care Centre

    OpenAIRE

    Ramu, D.; Ramesh, Rakesh S.; Manjunath, Suraj; Shivakumar; Goel, Vipin; Hemnath, G. N.; Alexander, Annie

    2015-01-01

    In India, Breast cancer is now the most common cancer in urban and 2nd most common in rural areas [1]. The incidence is rising, more younger women are getting affected and due to increase in survival rates there is an increase in the total number of women suffering from breast Cancer. So far there are no studies evaluating the pattern of breast prosthesis use in Indian scenario. The aim of this study is to address the patterns of external breast prosthesis used in India and view of Indian wom...

  6. Prosthetic rehabilitation of large mid-facial defect with magnet-retained silicone prosthesis

    Directory of Open Access Journals (Sweden)

    Kirti Jajoo Shrivastava

    2015-01-01

    Full Text Available Rehabilitation of maxillofacial defect patients is a challenging task. The most common prosthetic treatment problem with such patients is, getting adequate retention, stability, and support. In cases of large maxillofacial defect, movement of the prosthesis is inevitable. The primary objectives in rehabilitating the maxillofacial defect patients are to restore the function of mastication, deglutition, speech, and to achieve normal orofacial appearance. This clinical report describes maxillofacial prosthetic rehabilitation of large midfacial defect including orbit along with its contents, zygoma and soft tissues including half of the nose, cheeks, upper lip of left side, accompanying postsurgical microstomia and orofacial communication, which resulted from severe fungal infection mucormycosis. The defect in this case was restored with magnet retained two piece maxillofacial prosthesis having hollow acrylic resin framework and an overlying silicone facial prosthesis. The retention of prosthesis was further enhanced with the use of spectacles. This type of combination prosthesis enhanced the cosmesis and functional acceptability of prosthesis.

  7. Appearance of low signal intensity lines in MRI of silicone breast implants.

    Science.gov (United States)

    Stroman, P W; Rolland, C; Dufour, M; Grondin, P; Guidoin, R G

    1996-05-01

    Magnetic resonance (MR) images of five explanted mammary prostheses were obtained with a 1.5 T GE Signa system using a conventional spin-echo pulse sequence, in order to investigate the low-intensity curvilinear lines which may be observed in MR images of silicone gel-filled breast implants under pressure from fibrous capsules. MR images showed ellipsoid prostheses, often containing multiple low-intensity curvilinear lines which in some cases presented an appearance very similar to that of the linguine sign. Upon opening the fibrous capsules, however, all of the prostheses were found to be completely intact demonstrating that the appearance of multiple low signal intensity curvilinear lines in MR images of silicone gel-filled prostheses is not necessarily a sign of prosthesis rupture. The MR image features which are specific to the linguine sign must be more precisely defined.

  8. Cutaneous Silicone Granuloma Mimicking Breast Cancer after Ruptured Breast Implant

    Directory of Open Access Journals (Sweden)

    Waseem Asim Ghulam El-Charnoubi

    2011-01-01

    Full Text Available Cutaneous manifestations due to migration of silicone from ruptured implants are rare. Migrated silicone with cutaneous involvement has been found in the chest wall, abdominal wall, and lower extremities. We describe a case of cutaneous silicone granuloma in the breast exhibiting unusual growth mimicking breast cancer after a ruptured implant.

  9. Magnetic resonance imaging of breast prostheses | Corr | SA ...

    African Journals Online (AJOL)

    Breast MR imaging is the most accurate imaging investigation to detect breast prosthesis rupture. Rupture is common in older prostheses (> 10 years post implantation) and is often asymptomatic. The radiological signs of rupture are due to collapse of the elastomer shell which is eneveloped by silicone gel and when the ...

  10. Conventional or adhesive external breast prosthesis? A prospective study of the patients' preference after mastectomy

    NARCIS (Netherlands)

    Thijs-Boer, FM; Thijs, JT; van de Wiel, H.B.M.

    After having been subjected to radical mastectomy for breast cancer, women are usually Fitted with an external breast prosthesis. Different types of prostheses are available, but oncology nurses have few data enabling them to advise their patients adequately. in this prospective randomized crossover

  11. Should silicone prostheses be considered for specimen banking? A pilot study into their use for human biomonitoring.

    Science.gov (United States)

    Allan, Ian J; Bæk, Kine; Kringstad, Alfhild; Roald, Helge E; Thomas, Kevin V

    2013-09-01

    Persistent organic pollutant (POP) biomonitoring in humans is challenging and generally carried out using blood, breast milk or adipose tissue, with concentrations normalised to the lipid content of the sample matrix. The goal of this cross-sectional pilot study was to evaluate the validity and feasibility of explanted silicone prostheses as a matrix for persistent organic pollutant biomonitoring in humans. We postulate that pollutant concentrations in silicone prostheses inserted in the body will equilibrate with that in the body over time and provide a measure of the overall body burden. This study included silicone prostheses from 22 female patients of the Colosseum clinic (Oslo, Norway) collected between September 2010 and April 2012. Absorption of chlorinated and brominated POPs into silicone prostheses during implantation was observed. Relative levels of the different contaminants measured in prostheses were in agreement with those from serum and breast milk analyses from the general Norwegian population. The comparison of serum and breast milk-based literature data with prosthesis concentrations transposed into lipid-normalised concentrations supports the validity of the prosthesis measurements. The median of relative percent differences between measurements with replicate silicone prostheses from 11 patients was below 30%. Observed increases in prosthesis concentrations with patients' age were found to be very similar to literature data from studies of the Norwegian population. Silicone prostheses therefore represent a promising matrix for the biomonitoring of nonpolar and non-ionic pollutants in humans. Sample accessibility and body burden representativeness of the silicone prostheses suggest that specimen banking should be initiated. © 2013.

  12. Safely re-integrating silicone breast implants into the plastic surgery practice.

    Science.gov (United States)

    Gladfelter, Joanne

    2006-01-01

    In the early 1990s, it was reported that silicone breast implants were possibly responsible for serious damage to women's health. In January 1992, the Food and Drug Administration issued a voluntary breast implant moratorium and, in April, issued a ban on the use of silicone gel-filled implants for cosmetic breast augmentation. Since that time, silicone gel-filled breast implants have been available to women only for select cases: women seeking breast reconstruction or revision of an existing breast implant, women who have had breast cancer surgery, a severe injury to the breast, a birth defect that affects the breast, or a medical condition causing a severe breast deformity. Since the ban on the use of silicone gel-filled breast implants for cosmetic breast augmentation, numerous scientific studies have been conducted. To ensure patient safety, the American Board of Plastic Surgery believes that these scientific studies and the Food and Drug Administration's scrutiny of silicone gel-filled breast implants have been appropriate and necessary.

  13. Comparative study between body and surface coils in magnetic resonance mammography of silicone prosthesis

    International Nuclear Information System (INIS)

    Scaranelo, Anabel Medeiros

    2001-01-01

    Magnetic resonance imaging scans using predefined parameters were performed in patients with silicone breast implants. The same group of patients was submitted to magnetic resonance imaging scans using surface breast coils and body coils, and the results were compared. A total of 43 single-lumen silicone-gel breast implants in 24 patients were examined. The signal-to-noise ratio was greater for the breast coil than for the body coil. Radial folds were identified with equal resolution by both in almost 82% of the cases on the right side and 95% on the left side. In about 5% of the cases the folds were seen exclusively when the breast coil used. The linguine sign was almost equally with both methods. In just one case the linguine sign was observed only by using the breast coil. Identification of building or irregularity of contours were concordant using both techniques. We concluded that although magnetic resonance imaging quality is better using a dedicated coil, silicone breast implants can be assessed with the same diagnostic accuracy using a body coil. (author)

  14. Breast milk metal ion levels in a young and active patient with a metal-on-metal hip prosthesis.

    Science.gov (United States)

    Nelis, Raymond; de Waal Malefijt, Jan; Gosens, Taco

    2013-01-01

    Metal-on-metal resurfacing arthroplasty of the hip has been used increasingly over the last 10 years in younger active patients. The dissolution of the metal wear particles results in measurable increases in cobalt and chromium ions in the serum and urine of patients with a metal-on-metal bearing. We measured the cobalt, chromium, and molybdenum ion levels in urine; serum; and breast milk in a young and active patient with a metal-on-metal hip prosthesis after a pathologic fracture of the femoral neck. Metal-on-metal hip prosthesis leads to increasing levels of molybdenum in breast milk in the short-term follow-up. There are no increasing levels of chromium and cobalt ions in breast milk. Besides the already known elevated concentrations in serum of chromium and cobalt after implantation of a metal-on-metal hip prosthesis, we found no increasing levels of chromium and cobalt in urine. Copyright © 2013 Elsevier Inc. All rights reserved.

  15. Untreated silicone breast implant rupture

    DEFF Research Database (Denmark)

    Hölmich, Lisbet R; Vejborg, Ilse M; Conrad, Carsten

    2004-01-01

    Implant rupture is a well-known complication of breast implant surgery that can pass unnoticed by both patient and physician. To date, no prospective study has addressed the possible health implications of silicone breast implant rupture. The aim of the present study was to evaluate whether untre...

  16. Novel use of an air-filled breast prosthesis to allow radiotherapy to recurrent colonic cancer.

    LENUS (Irish Health Repository)

    O'Duffy, F

    2012-02-01

    AiM: The authors present the novel and successful use of an air-filled breast prosthesis for extra pelvic exclusion of small bowel to facilitate adjuvant radiotherapy following resection of recurrent adenocarcinoma of the ascending bowel. The therapeutic use of radiotherapy in colon cancer can cause acute or chronic radiation enteropathy. Mobile small bowel can be sequestered in \\'dead space\\' or by adhesions exposing it to adjuvant radiotherapy. A variety of pelvic partitioning methods have been described to exclude bowel from radiation fields using both native and prosthetic materials. METHOD: In this case a 68 year old presented with ascending colon adenocarcinoma invading the peritoneum and underwent en bloc peritoneal resection. Thirty-seven months later surveillance CT identified a local recurrence. Subsequent resection resulted in a large iliacus muscle defect which would sequester small bowel loops thus exposing the patient to radiation enteropathy. The lateral position of the defect precluded the use of traditional pelvic partitioning methods which would be unlikely to remain in place long enough to allow radiotherapy. A lightweight air-filled breast prosthesis (Allergan 133 FV 750 cms) secured in place with an omentoplasty was used to fill the defect. RESULTS: Following well tolerated radiotherapy the prosthesis was deflated under ultrasound guidance and removed via a 7-cm transverse incision above the right iliac crest. The patient is disease free 18 months later with no evidence of treatment related morbidity. CONCLUSION: The use of a malleable air-filled prosthesis for pelvic partitioning allows specific tailoring of the prosthesis size and shape for individual patient defects. It is also lightweight enough to be secured in place using an omentoplasty to prevent movement related prosthesis migration. In the absence of adequate omentum a mesh sling may be considered to allow fixation. In this case the anatomy of the prosthesis position allowed for its

  17. A comparison of 500 prefilled textured saline breast implants versus 500 standard textured saline breast implants: is there a difference in deflation rates?

    Science.gov (United States)

    Stevens, W Grant; Hirsch, Elliot M; Stoker, David A; Cohen, Robert

    2006-06-01

    This study provides the first large-volume (1000 implant) comparison of the deflation rates of Poly Implant Prosthesis prefilled textured saline breast implants versus a control group of Mentor Siltex textured saline implants. A consecutive series of 500 Poly Implant Prosthesis prefilled textured saline breast implants was compared with a consecutive series of 500 Mentor Siltex breast implants. Each breast implant was evaluated for a 4-year period, and the annual deflation rate (number of deflations during a given year divided by the total number of implants) and cumulative deflation rate (cumulative total of deflations through a given year divided by the total number of implants) were recorded. Statistical significance was calculated using the Fisher's exact test at year 1 and the chi-square analysis at years 2 through 4. The cumulative deflation rates of the Poly Implant Prosthesis implants was as follows: year 1, 1.2 percent; year 2, 5.6 percent; year 3, 11.4 percent; and year 4, 15.4 percent. The cumulative deflation rates of the Mentor implants was: year 1, 0.2 percent; year 2, 0.6 percent; year 3, 1.6 percent; and year 4, 4.4 percent. At year 1, the difference between deflation rates was not statistically significant (Fisher's exact test, p > 0.05). However, at year 2 (chi-square, 13.29; p deflation rates of Poly Implant Prosthesis prefilled textured saline breast implants and Mentor Siltex breast implants at year 2, year 3, and year 4. After 4 years, the 15.56 percent cumulative deflation rate of Poly Implant Prosthesis implants was over 3.5 times higher than the 4.31 percent deflation rate of the Mentor Siltex implants. There may be several factors contributing to the higher deflation rate seen in Poly Implant Prosthesis implants, including possible in vitro deflation before implantation and silicone shell curing technique. Nevertheless, this statistically significant deflation difference must be taken into account when balancing the risks and benefits of

  18. A fiber-reinforced composite prosthesis restoring a lateral midfacial defect: a clinical report.

    Science.gov (United States)

    Kurunmäki, Hemmo; Kantola, Rosita; Hatamleh, Muhanad M; Watts, David C; Vallittu, Pekka K

    2008-11-01

    This clinical report describes the use of a glass fiber-reinforced composite (FRC) substructure to reinforce the silicone elastomer of a large facial prosthesis. The FRC substructure was shaped into a framework and embedded into the silicone elastomer to form a reinforced facial prosthesis. The prosthesis is designed to overcome the disadvantages associated with traditionally fabricated prostheses; namely, delamination of the silicone of the acrylic base, poor marginal adaptation over time, and poor simulation of facial expressions.

  19. Different techniques in fabrication of ocular prosthesis.

    Science.gov (United States)

    Cevik, Pinar; Dilber, Erhan; Eraslan, Oguz

    2012-11-01

    Loss of an eye caused by cancer, trauma, or congenital defect creates a deep psychological impact on an individual's life especially social and professional life. Custom-made prosthesis, compared to stock prosthesis, provides a better fit to the eye socket, better cosmetic results, and less discomfort to the patient in the long term. The main objective of this article was to describe 3 different alternative and practical techniques of fabricating custom-made ocular prosthesis. An impression of anophthalmic socket was made with the addition of cured silicone-based precision impression material in all techniques. A master cast was prepared and duplicated with condensation silicone. A self-cure acrylic resin was polymerized in the silicone model and was fitted into the patient's eye socket. A digital photograph of the patient's iris was made using a digital camera and printed on good-quality photo paper in various shades and sizes in the first and the second techniques. Then the photo paper was coated with PVC so as not to allow any color flowing. The proper iris was then inserted to the acrylic base. The prosthesis was final processed using orthodontic heat polymerizing clear acrylic resin.In the other technique, after the trying-in process with wax pattern, an acrylic base was fabricated using heat polymerizing scleral acrylic resin. The prosthetic iris was fabricated from a transparent contact lens by painting the lens with watercolor paints and attaching it to an acrylic resin with tissue conditioner. The final process was made with heat polymerizing transparent acrylic resin. Custom-made prosthesis allows better esthetic and functional results to the patient in comparison to stock prosthesis. Further follow-up is necessary to check the condition and fit of the ocular prosthesis in such patients.

  20. Long-term health status of Danish women with silicone breast implants

    DEFF Research Database (Denmark)

    Breiting, Vibeke B; Hölmich, Lisbet R; Brandt, Bodil

    2004-01-01

    Long-term safety data are important in the evaluation of possible adverse health outcomes related to silicone breast implants. The authors evaluated long-term symptoms and conditions and medication use among 190 Danish women with cosmetic silicone breast implants compared with 186 women who had u...

  1. Multimodality Imaging-based Evaluation of Single-Lumen Silicone Breast Implants for Rupture.

    Science.gov (United States)

    Seiler, Stephen J; Sharma, Pooja B; Hayes, Jody C; Ganti, Ramapriya; Mootz, Ann R; Eads, Emily D; Teotia, Sumeet S; Evans, W Phil

    2017-01-01

    Breast implants are frequently encountered on breast imaging studies, and it is essential for any radiologist interpreting these studies to be able to correctly assess implant integrity. Ruptures of silicone gel-filled implants often occur without becoming clinically obvious and are incidentally detected at imaging. Early diagnosis of implant rupture is important because surgical removal of extracapsular silicone in the breast parenchyma and lymphatics is difficult. Conversely, misdiagnosis of rupture may prompt a patient to undergo unnecessary additional surgery to remove the implant. Mammography is the most common breast imaging examination performed and can readily depict extracapsular free silicone, although it is insensitive for detection of intracapsular implant rupture. Ultrasonography (US) can be used to assess the internal structure of the implant and may provide an economical method for initial implant assessment. Common US signs of intracapsular rupture include the "keyhole" or "noose" sign, subcapsular line sign, and "stepladder" sign; extracapsular silicone has a distinctive "snowstorm" or echogenic noise appearance. Magnetic resonance (MR) imaging is the most accurate and reliable means for assessment of implant rupture and is highly sensitive for detection of both intracapsular and extracapsular rupture. MR imaging findings of intracapsular rupture include the keyhole or noose sign, subcapsular line sign, and "linguine" sign, and silicone-selective MR imaging sequences are highly sensitive to small amounts of extracapsular silicone. © RSNA, 2017.

  2. Finger prosthesis: a boon to handicapped.

    Science.gov (United States)

    Gupta, Ridhima; Kumar, Lakshya; Rao, Jitendra; Singh, Kamleshwar

    2013-08-29

    This is a clinical case report of a 52-year-old male patient with four partially missing fingers of the left hand. The article describes the clinical and laboratory procedure of making prosthesis with modern silicone material. A wax pattern was fabricated using the right hand of the patient. A special type of wax was formulated to make the pattern so that it can be easily moulded and carved. Intrinsic and extrinsic staining was also performed to match the adjacent skin colour. The patient was given the finger prosthesis and was asked to use a half glove (sports) to mask the junction between the prosthesis and the normal tissue. It also provides additional retention to the artificial fingers. The patient felt his social acceptance improved after wearing the finger prosthesis.

  3. Comparative study between body and surface coils in magnetic resonance mammography of silicone prosthesis; Estudo comparativo entre bobinas de corpo e superficie na mamografia por ressonancia magnetica de proteses de silicone

    Energy Technology Data Exchange (ETDEWEB)

    Scaranelo, Anabel Medeiros [Universidade Federal de Sao Paulo (UNIFESP), SP (Brazil). Dept. de Diagnostico por Imagem]. E-mail: anabelms@uol.com.br

    2001-04-01

    Magnetic resonance imaging scans using predefined parameters were performed in patients with silicone breast implants. The same group of patients was submitted to magnetic resonance imaging scans using surface breast coils and body coils, and the results were compared. A total of 43 single-lumen silicone-gel breast implants in 24 patients were examined. The signal-to-noise ratio was greater for the breast coil than for the body coil. Radial folds were identified with equal resolution by both in almost 82% of the cases on the right side and 95% on the left side. In about 5% of the cases the folds were seen exclusively when the breast coil used. The linguine sign was almost equally with both methods. In just one case the linguine sign was observed only by using the breast coil. Identification of building or irregularity of contours were concordant using both techniques. We concluded that although magnetic resonance imaging quality is better using a dedicated coil, silicone breast implants can be assessed with the same diagnostic accuracy using a body coil. (author)

  4. 21 CFR 878.3720 - Tracheal prosthesis.

    Science.gov (United States)

    2010-04-01

    ...) Identification. The tracheal prosthesis is a rigid, flexible, or expandable tubular device made of a silicone... of the trachea or trachealbronchial tree. It may be unbranched or contain one or two branches. The...

  5. Microfabrication of an Implantable silicone Microelectrode array for an epiretinal prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Maghribi, Mariam Nader [Univ. of California, Davis, CA (United States)

    2003-06-10

    Millions of people suffering from diseases such as retinitis pigmentosa and macular degeneration are legally blind due to the loss of photoreceptor function. Fortunately a large percentage of the neural cells connected to the photoreceptors remain viable, and electrical stimulation of these cells has been shown to result in visual perception. These findings have generated worldwide efforts to develop a retinal prosthesis device, with the hope of restoring vision. Advances in microfabrication, integrated circuits, and wireless technologies provide the means to reach this challenging goal. This dissertation describes the development of innovative silicone-based microfabrication techniques for producing an implantable microelectrode array. The microelectrode array is a component of an epiretinal prosthesis being developed by a multi-laboratory consortium. This array will serve as the interface between an electronic imaging system and the human eye, directly stimulating retinal neurons via thin film conducting traces. Because the array is intended as a long-term implant, vital biological and physical design requirements must be met. A retinal implant poses difficult engineering challenges due to the size of the intraocular cavity and the delicate retina. Not only does it have to be biocompatible in terms of cytotoxicity and degradation, but it also has to be structurally biocompatible, with regard to smooth edges and high conformability; basically mimicking the biological tissue. This is vital to minimize stress and prevent physical damage to the retina. Also, the device must be robust to withstand the forces imposed on it during fabrication and implantation. In order to meet these biocompatibility needs, the use of non-conventional microfabrication materials such as silicone is required. This mandates the enhancement of currently available polymer-based fabrication techniques and the development of new microfabrication methods. Through an iterative process, devices

  6. Use of silicone implants in reconstructive plastic surgery for breast cancer

    Directory of Open Access Journals (Sweden)

    D. D. Pak

    2012-01-01

    Full Text Available The paper considers procedures for reconstructive plastic operations, by using silicone implants, in patients with breast cancer. It analyzes 592 primary breast repairs and evaluates their aesthetic effects and complications. The surgical procedures are described.

  7. Effects of silicone expanders and implants on echocardiographic image quality after breast reconstruction.

    Science.gov (United States)

    Pignatti, Marco; Mantovani, Francesca; Bertelli, Luca; Barbieri, Andrea; Pacchioni, Lucrezia; Loschi, Pietro; De Santis, Giorgio

    2013-08-01

    Use of silicone expanders and implants is the most common breast reconstruction technique after mastectomy. Postmastectomy patients often need echocardiographic monitoring of potential cardiotoxicity induced by cancer chemotherapy. The impairment of the echocardiographic acoustic window caused by silicone implants for breast augmentation has been reported. This study investigates whether the echocardiographic image quality was impaired in women reconstructed with silicone expanders and implants. The records of 44 consecutive women who underwent echocardiographic follow-up after breast reconstruction with expanders and implants at the authors' institution from January of 2000 to August of 2012 were reviewed. The population was divided into a study group (left or bilateral breast expanders/implants, n=30) and a control group (right breast expanders/implants, n=14). The impact of breast expanders/implants on echocardiographic image quality was tested (analysis of covariance model). Patients with a breast expander/implant (left or bilateral and right breast expanders/implants) were included. The mean volume of the breast devices was 353.2±125.5 cc. The quality of the echocardiographic images was good or sufficient in the control group; in the study group, it was judged as adequate in only 50 percent of cases (15 patients) and inadequate in the remaining 15 patients (pimplants in postmastectomy left breast reconstruction considerably reduce the image quality of echocardiography. This may have important clinical implications, given the need for periodic echocardiographic surveillance before and during chemotherapy. Therapeutic, III.

  8. Patient satisfaction with postmastectomy breast reconstruction: a comparison of saline and silicone implants.

    Science.gov (United States)

    McCarthy, Colleen M; Klassen, Anne F; Cano, Stefan J; Scott, Amie; Vanlaeken, Nancy; Lennox, Peter A; Alderman, Amy K; Mehrara, Babak J; Disa, Joseph J; Cordeiro, Peter G; Pusic, Andrea L

    2010-12-15

    At a time when the safety and effectiveness of breast implants remains under close scrutiny, it is important to provide reliable and valid evidence regarding patient outcomes. In the setting of postmastectomy reconstruction, patient satisfaction and quality of life may be the most significant outcome variables when evaluating surgical success. The objective of the current study was to identify predictors of patient satisfaction with breast appearance, including implant type, in a large sample of women who underwent breast reconstruction surgery using implants. A multicenter, cross-sectional study design was used. A total of 672 women who had completed postmastectomy, implant-based reconstruction at 1 of 3 centers in North America were asked to complete the BREAST-Q (Reconstruction Module). Multivariate linear regression modeling was performed. Completed questionnaire data were available for 482 of the 672 patients. In 176 women, silicone implants were placed and in 306, saline implants were used. The multivariate model confirmed that patients' satisfaction with their breasts was significantly higher in patients with silicone implants (P = .016). The receipt of postmastectomy radiotherapy was found to have a significant, negative effect on breast satisfaction (Pimplant recipients. In addition, for women who received either silicone or saline implants, satisfaction diminished over time (P = .017). In the setting of postmastectomy reconstruction, patients who received silicone breast implants reported significantly higher satisfaction with the results of reconstruction than those who received saline implants. This information can be used to optimize shared medical decision-making by providing patients with realistic postoperative expectations. Copyright © 2010 American Cancer Society.

  9. Silicone breast implants and connective tissue disease

    DEFF Research Database (Denmark)

    Lipworth, Loren; Holmich, Lisbet R; McLaughlin, Joseph K

    2011-01-01

    The association of silicone breast implants with connective tissue diseases (CTDs), including systemic sclerosis, systemic lupus erythematosus, rheumatoid arthritis, and fibromyalgia, as well as a hypothesized new "atypical" disease, which does not meet established diagnostic criteria for any known...... CTD, has been extensively studied. We have reviewed the epidemiologic literature regarding an association between cosmetic breast implants and CTDs, with particular emphasis on results drawn from the most recent investigations, many of which are large cohort studies with long-term follow-up, as well...... as on those studies that address some of the misinformation and historically widespread claims regarding an association between breast implants and CTDs. These claims have been unequivocally refuted by the remarkably consistent evidence from published studies, as well as numerous independent meta...

  10. Silicone-based composite materials simulate breast tissue to be used as ultrasonography training phantoms.

    Science.gov (United States)

    Ustbas, Burcin; Kilic, Deniz; Bozkurt, Ayhan; Aribal, Mustafa Erkin; Akbulut, Ozge

    2018-03-02

    A silicone-based composite breast phantom is fabricated to be used as an education model in ultrasonography training. A matrix of silicone formulations is tracked to mimic the ultrasonography and tactile response of human breast tissue. The performance of two different additives: (i) silicone oil and (ii) vinyl-terminated poly (dimethylsiloxane) (PDMS) are monitored by a home-made acoustic setup. Through the use of 75 wt% vinyl-terminated PDMS in two-component silicone elastomer mixture, a sound velocity of 1.29 ± 0.09 × 10 3  m/s and an attenuation coefficient of 12.99 ± 0.08 dB/cm-values those match closely to the human breast tissue-are measured with 5 MHz probe. This model can also be used for needle biopsy as well as for self-exam trainings. Herein, we highlight the fabrication of a realistic, durable, accessible, and cost-effective training platform that contains skin layer, inner breast tissue, and tumor masses. Copyright © 2018. Published by Elsevier B.V.

  11. Novel use of an air-filled breast prosthesis to allow radiotherapy to recurrent colonic cancer.

    LENUS (Irish Health Repository)

    O'Duffy, F

    2011-03-01

    AiM: The authors present the novel and successful use of an air-filled breast prosthesis for extra pelvic exclusion of small bowel to facilitate adjuvant radiotherapy following resection of recurrent adenocarcinoma of the ascending bowel. The therapeutic use of radiotherapy in colon cancer can cause acute or chronic radiation enteropathy. Mobile small bowel can be sequestered in \\'dead space\\' or by adhesions exposing it to adjuvant radiotherapy. A variety of pelvic partitioning methods have been described to exclude bowel from radiation fields using both native and prosthetic materials.

  12. Mammary prostheses may hide breast cancer. Silicon implants and cancer diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Heywang, S H

    1987-10-30

    Mammoplasty with silicon implants is risky: In women wearing protheses of this type, carcinomas of the breast may be diagnosed in a more advanced stage than in women without silicon implants. This is the result of a study by US oncologists and was proved by observation in Grosshadern hospital, Munich. (orig.)

  13. Nasal prosthesis for a patient with xeroderma pigmentosum

    Directory of Open Access Journals (Sweden)

    Suresh Kumar

    2013-01-01

    Full Text Available Acquired facial defects caused by extirpation of neoplasms, congenital malformations or traumatic injury results in a huge functional, cosmetic and psychological handicap in those patients. These defects can be restored by facial prosthesis using different materials and retention methods to achieve a lifelike appearance and function. This clinical report describes a treatment schedule using silicone nasal prosthesis, which is mechanically retained for a patient who has undergone a partial rhinectomy due to basal cell carcinoma of the nose. The prosthesis was made to restore the esthetic appearance of patient with a mechanically retained design using a spectacle glass frame without any prosthetic adhesives so that the patient is more comfortable and confident to resume daily activities.

  14. Combination of chemical suppression techniques for dual suppression of fat and silicone at diffusion-weighted MR imaging in women with breast implants

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Dow-Mu; Hughes, J. [Royal Marsden Hospital, Department of Radiology, Sutton (United Kingdom); Blackledge, M.; Leach, M.O.; Collins, D.J. [Institute of Cancer Research, CR UK-EPSRC Cancer Imaging Centre, Sutton (United Kingdom); Burns, S. [Nuada 3T MRI Centre, London (United Kingdom); Stemmer, A.; Kiefer, B. [Siemens Healthcare, Erlangen (Germany)

    2012-12-15

    Silicone breast prostheses prove technically challenging when performing diffusion-weighted MR imaging in the breasts. We describe a combined fat and chemical suppression scheme to achieve dual suppression of fat and silicone, thereby improving the quality of diffusion-weighted images in women with breast implants. MR imaging was performed at 3.0 and 1.5 T in women with silicone breast implants using short-tau inversion recovery (STIR) fat-suppressed echo-planar (EPI) diffusion-weighted MR imaging (DWI) on its own and combined with the slice-select gradient-reversal (SSGR) technique. Imaging was performed using dedicated breast imaging coils. Complete suppression of the fat and silicone signal was possible at 3.0 T using EPI DWI with STIR and SSGR, evaluated with dedicated breast coils. However, a residual silicone signal was still perceptible at 1.5 T using this combined approach. Nevertheless, a further reduction in silicone signal at 1.5 T could be achieved by employing thinner slice partitions and the addition of the chemical-selective fat-suppression (CHESS) technique. DWI using combined STIR and SSGR chemical suppression techniques is feasible to eliminate or reduce silicone signal from prosthetic breast implants. (orig.)

  15. Diagnosis of breast cancer at dynamic MRI in patients with breast augmentation by paraffin or silicone injection

    International Nuclear Information System (INIS)

    Youk, J.H.; Son, E.J.; Kim, E.-K.; Kim, J.-A.; Kim, M.J.; Kwak, J.Y.; Lee, S.M.

    2009-01-01

    Aim: To determine the diagnostic performance of dynamic magnetic resonance imaging (MRI) for breast cancer in breasts augmented with liquid paraffin or silicone injection. Materials and methods: Among 62 patients with breast augmentation by liquid paraffin or silicone injection who had undergone dynamic breast MRI at our institution, 27 women, who had pathological diagnosis or at least 1-year MRI follow-up, were included in this retrospective study and their MRI images were reviewed. For enhancing lesions on MRI, the morphological features, enhancement kinetics, and BI-RADS assessment category were analysed. The lesion characteristics at MRI were correlated with the final diagnosis based on the histopathological result or at least 1-year MRI follow-up. Results: Of the 27 patients, 17 enhancing lesions in 13 patients were found on MRI. All six lesions that were confirmed as malignancy showed suspicious morphological findings and type 2 or 3 enhancement kinetics, assigned to BI-RADS category 4 or 5. Of the remaining 11 benign lesions, 10 showed benign-favouring morphological findings, and all showed type 1 enhancement kinetics, assigned to BI-RADS category 2 or 4. Conclusion: In patients with breasts injected with foreign material, MRI was used to successfully diagnose malignant breast lesions and could be the diagnostic method of choice. Analysis of the morphological and kinetic features at MRI in conjunction with clinical findings is essential.

  16. The relationship of silicone breast implants and cancer at other sites.

    Science.gov (United States)

    Brinton, Louise A

    2007-12-01

    Although most attention regarding the effects of silicone breast implants on cancer risk has focused on breast cancer, there have also been concerns regarding effects on other cancers. This includes malignancies that could occur as a result of foreign-body carcinogenesis (sarcomas) or immune alterations (hematopoietic malignancies), or cancers suggested as possibly elevated on the basis of previous epidemiologic studies (cancers of the cervix, vulva, lung, and brain). Searches of the English language literature on the topic of silicone breast implants and cancer risk were conducted and reviewed to determine relationships that might have etiologic relevance. Epidemiologic studies provide no support for an increased risk of either sarcoma or multiple myeloma among breast implant recipients, disputing clinical and laboratory findings suggesting such a link. Although a number of epidemiologic studies have demonstrated elevated risks of cervical, vulvar, and lung cancers among breast implant patients, it is likely that these excesses relate more to lifestyle characteristics (e.g., cigarette smoking, sexual behavior) than to the effects of the implants. Brain cancer excesses, suggested in one study, have not been confirmed in either an update of the mortality experience in this study or on the basis of other investigations. At present, there is no convincing evidence that breast implants alter the risk of nonbreast malignancies. Breast implant patients should continue to be monitored for longer term risks and to assess whether cancer risk is influenced by various patient and implant characteristics.

  17. Long-Term Health Outcomes in Women With Silicone Gel Breast Implants: A Systematic Review.

    Science.gov (United States)

    Balk, Ethan M; Earley, Amy; Avendano, Esther A; Raman, Gowri

    2016-02-02

    Silicone gel breast implants were removed from the U.S. market for cosmetic use in 1992 owing to safety concerns. They were reintroduced in 2006, with a call for improved surveillance of clinical outcomes. To systematically review the literature regarding specific long-term health outcomes in women with silicone gel breast implants, including cancer; connective tissue, rheumatologic, and autoimmune diseases; neurologic diseases; reproductive issues, including lactation; offspring issues; and mental health issues (depression and suicide). MEDLINE, EMBASE, and Ovid Healthstar (inception through 30 June 2015), and the Cochrane Central Register of Controlled Trials and Cochrane Database of Systematic Reviews (through the first quarter of 2015). 4 researchers double-screened articles for longitudinal studies that compared women with and without breast implants and reported long-term health outcomes of interest. 4 researchers extracted data on participant and implant characteristics, analytic methods, and results. 32 studies (in 58 publications) met eligibility criteria. Random-effects model meta-analyses of effect sizes were conducted when feasible. For most outcomes, there was at most only a single adequately adjusted study, which usually found no significant associations. There were possible associations with decreased risk for primary breast and endometrial cancers and increased risks for lung cancer, rheumatoid arthritis, Sjögren syndrome, and Raynaud syndrome. Evidence on breast implants and other outcomes either was limited or did not exist. The evidence was most frequently not specific to silicone gel implants, and studies were rarely adequately adjusted for potential confounders. The evidence remains inconclusive about any association between silicone gel implants and long-term health outcomes. Better evidence is needed from existing large studies, which can be reanalyzed to clarify the strength of associations between silicone gel implants and health outcomes

  18. Correlation between MRI results and intraoperative findings in patients with silicone breast implants

    NARCIS (Netherlands)

    N. Lindenblatt (Nicole); K. El-Rabadi (Karem); T. Helbich (Thomas); H. Czembirek (Heinrich); M. Deutinger (Maria); H. Benditte-Klepetko (Heike)

    2014-01-01

    textabstractBackground:Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture.

  19. Intra-prosthetic breast MR virtual navigation: a preliminary study for a new evaluation of silicone breast implants.

    Science.gov (United States)

    Moschetta, Marco; Telegrafo, Michele; Capuano, Giulia; Rella, Leonarda; Scardapane, Arnaldo; Angelelli, Giuseppe; Stabile Ianora, Amato Antonio

    2013-10-01

    To assess the contribute of intra-prosthetic MRI virtual navigation for evaluating breast implants and detecting implant ruptures. Forty-five breast implants were evaluated by MR examination. Only patients with a clinical indication were assessed. A 1.5-T device equipped with a 4-channel breast coil was used by performing axial TSE-T2, axial silicone-only, axial silicone suppression and sagittal STIR images. The obtained dicom files were also analyzed by using virtual navigation software. Two blinded radiologists evaluated all MR and virtual images. Eight patients for a total of 13 implants underwent surgical replacement. Sensitivity, specificity, accuracy, positive predictive value (PPV) and negative predictive value (NPV) were calculated for both imaging strategies. Intra-capsular rupture was diagnosed in 13 out of 45 (29%) implants by using MRI. Basing on virtual navigation, 9 (20%) cases of intra-capsular rupture were diagnosed. Sensitivity, specificity, accuracy, PPV and NPV values of 100%, 86%, 89%, 62% and 100%, respectively, were found for MRI. Virtual navigation increased the previous values up to 100%, 97%, 98%, 89% and 100%. Intra-prosthetic breast MR virtual navigation can represent an additional promising tool for the evaluation of breast implants being able to reduce false positives and to provide a more accurate detection of intra-capsular implant rupture signs. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Release of low molecular weight silicones and platinum from silicone breast implants.

    Science.gov (United States)

    Lykissa, E D; Kala, S V; Hurley, J B; Lebovitz, R M

    1997-12-01

    We have conducted a series of studies addressing the chemical composition of silicone gels from breast implants as well as the diffusion of low molecular weight silicones (LM-silicones) and heavy metals from intact implants into various surrounding media, namely, lipid-rich medium (soy oil), aqueous tissue culture medium (modified Dulbecco's medium, DMEM), or an emulsion consisting of DMEM plus 10% soy oil. LM-silicones in both implants and surrounding media were detected and quantitated using gas chromatography (GC) coupled with atomic emission (GC-AED) as well as mass spectrometric (GC/MS) detectors, which can detect silicones in the nanogram range. Platinum, a catalyst used in the preparation of silicone gels, was detected and quantitated using inductive argon-coupled plasma/mass spectrometry (ICP-MS), which can detect platinum in the parts per trillion range. Our results indicate that GC-detectable low molecular weight silicones contribute approximately 1-2% to the total gel mass and consist predominantly of cyclic and linear poly-(dimethylsiloxanes) ranging from 3 to 20 siloxane [(CH3)2-Si-O] units (molecular weight 200-1500). Platinum can be detected in implant gels at levels of approximately 700 micrograms/kg by ICP-MS. The major component of implant gels appears to be high molecular weight silicone polymers (HM-silicones) too large to be detected by GC. However, these HM-silicones can be converted almost quantitatively (80% by mass) to LM-silicones by heating implant gels at 150-180 degrees C for several hours. We also studied the rates at which LM-silicones and platinum leak through the intact implant outer shell into the surrounding media under a variety of conditions. Leakage of silicones was greatest when the surrounding medium was lipid-rich, and up to 10 mg/day LM-silicones was observed to diffuse into a lipid-rich medium per 250 g of implant at 37 degrees C. This rate of leakage was maintained over a 7-day experimental period. Similarly, platinum was

  1. Silicone implant incompatibility syndrome (SIIS) in a 57-year-old woman with unilateral silicone breast implant

    DEFF Research Database (Denmark)

    Schierbeck, Juliane; Davidsen, Jesper Rømhild; Grindsted Nielsen, Sanne

    2017-01-01

    implants can lead to different interstitial lung manifestations predominantly with granuloma evolvement, leading to the so-called silicone implant incompatibility syndrome (SIIS). This case describes a 57-year-old woman with multiple lung infiltrations and a left-sided breast implant. The implant had been...

  2. Destiny rides again: the reappearance of silicone gel-filled breast implant toxicity.

    Science.gov (United States)

    Brawer, A E

    2017-09-01

    Background Twenty-five years ago attorneys representing ailing women in class action litigation against silicone breast implant manufacturers made the procedural error of defining silicone-induced toxicity in the courtroom before it was properly studied in the exam room. This aberrant methodology perverted the proper research process, rendered verification of any real disease elusive, and cemented the groundwork for a repeat public health crisis potentially affecting two million women in the USA who possess new silicone gel devices inserted over the past 10 years. Patients and methods Six women, previously well, aged 27 to 53 (mean 42), were recipients of the new generations of cohesive silicone gel-filled breast implants approved for general use by the Food and Drug Administration (FDA) since December of 2006. They averaged seven years of total implantation time, and none experienced implant rupture. Results All six became ill on average 3.5 years from the time of implantation. By seven years the women manifested multiple types of skin rashes, polyarthritis, fatigue, protracted AM stiffness, myalgias, headaches, photosensitivity, hair loss, paresthesias, tinnitus, lymphadenopathy, chest pain, cognitive dysfunction, dry eyes, skin pigment changes, itching, muscle twitching, dizziness, nausea, easy bruising, and odor and smell sensitivity. Three of the four who were explanted noted improvement and/or resolution of at least 50% of their total disease manifestations. Conclusions These six women are representative of over 70,000 other breast implant recipients who, over the past three years, have had their new silicone devices permanently removed because of alleged gel-induced toxicity. The recurrence of this public health crisis has been fueled by manufacturers' research fraud, FDA ineptness, faulty informed consent, patient abandonment, proprietary manufacturing secrecy, misleading advertising, physician indifference, aberrant research methodology, and lax

  3. Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Herborn, Christoph U. [Institute of Diagnostic Radiology, University Hospital, Zuerich (Switzerland); Department of Diagnostic and Interventional Radiology, University Hospital Essen, Hufelandstrasse 55, 45128 Essen (Germany); Marincek, Borut; Erfmann, Daniel; Kubik-Huch, Rahel A. [Institute of Diagnostic Radiology, University Hospital, Zuerich (Switzerland); Meuli-Simmen, Claudia; Wedler, Volker [Department of Surgery, Clinic for Reconstructive Surgery, University Hospital, Zurich (Switzerland); Bode-Lesniewska, Beate [Department of Pathology, University Hospital, Zurich (Switzerland)

    2002-09-01

    The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance imaging of the breast was performed on a 1.5-T system using a dedicated surface breast coil. Axial and sagittal T2-weighted fast spin-echo as well as dynamic contrast-enhanced T1-weighted gradient-recalled-echo sequences were acquired. The linguine sign indicating collapse of the silicone shell or siliconomas indicating free silicone proved implant rupture, whereas early focal contrast enhancement of a lesion was suspicious for malignancy. The sensitivity for detection of implant rupture was 86.7% with a specificity of 88.5%. The positive and negative predictive values were 81.3 and 92.0%, respectively. The linguine sign as a predictor of intracapsular implant rupture had a sensitivity of 80% with a specificity of 96.2%. Magnetic resonance imaging revealed two lesions with suspicious contrast enhancement (one carcinoma, one extra-abdominal fibromatosis). Magnetic resonance imaging is a reliable and reproducible technique for diagnosing both implant rupture and malignant lesions in women after breast augmentation and reconstruction. (orig.)

  4. Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy

    International Nuclear Information System (INIS)

    Herborn, Christoph U.; Marincek, Borut; Erfmann, Daniel; Kubik-Huch, Rahel A.; Meuli-Simmen, Claudia; Wedler, Volker; Bode-Lesniewska, Beate

    2002-01-01

    The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance imaging of the breast was performed on a 1.5-T system using a dedicated surface breast coil. Axial and sagittal T2-weighted fast spin-echo as well as dynamic contrast-enhanced T1-weighted gradient-recalled-echo sequences were acquired. The linguine sign indicating collapse of the silicone shell or siliconomas indicating free silicone proved implant rupture, whereas early focal contrast enhancement of a lesion was suspicious for malignancy. The sensitivity for detection of implant rupture was 86.7% with a specificity of 88.5%. The positive and negative predictive values were 81.3 and 92.0%, respectively. The linguine sign as a predictor of intracapsular implant rupture had a sensitivity of 80% with a specificity of 96.2%. Magnetic resonance imaging revealed two lesions with suspicious contrast enhancement (one carcinoma, one extra-abdominal fibromatosis). Magnetic resonance imaging is a reliable and reproducible technique for diagnosing both implant rupture and malignant lesions in women after breast augmentation and reconstruction. (orig.)

  5. Breast augmentation and reconstructive surgery: MR imaging of implant rupture and malignancy.

    Science.gov (United States)

    Herborn, Christoph U; Marincek, Borut; Erfmann, Daniel; Meuli-Simmen, Claudia; Wedler, Volker; Bode-Lesniewska, Beate; Kubik-Huch, Rahel A

    2002-09-01

    The purpose of this study was to assess the diagnostic accuracy of MRI in detecting prosthesis integrity and malignancy after breast augmentation and reconstruction. Forty-one implants in 25 patients were analyzed by MRI before surgical removal. Imaging results were compared with ex vivo findings. Magnetic resonance imaging of the breast was performed on a 1.5-T system using a dedicated surface breast coil. Axial and sagittal T2-weighted fast spin-echo as well as dynamic contrast-enhanced T1-weighted gradient-recalled-echo sequences were acquired. The linguine sign indicating collapse of the silicone shell or siliconomas indicating free silicone proved implant rupture, whereas early focal contrast enhancement of a lesion was suspicious for malignancy. The sensitivity for detection of implant rupture was 86.7% with a specificity of 88.5%. The positive and negative predictive values were 81.3 and 92.0%, respectively. The linguine sign as a predictor of intracapsular implant rupture had a sensitivity of 80% with a specificity of 96.2%. Magnetic resonance imaging revealed two lesions with suspicious contrast enhancement (one carcinoma, one extra-abdominal fibromatosis). Magnetic resonance imaging is a reliable and reproducible technique for diagnosing both implant rupture and malignant lesions in women after breast augmentation and reconstruction.

  6. Fluorodeoxyglucose--positive internal mammary lymph node in breast cancer patients with silicone implants: is it always metastatic cancer?

    Science.gov (United States)

    Soudack, Michalle; Yelin, Alon; Simansky, David; Ben-Nun, Alon

    2013-07-01

    Patients with breast cancer following mastectomy and silicone implant reconstruction may have enlarged internal mammary lymph nodes with pathological uptake on positron emission tomography with (18)F-fluorodeoxyglucose. This lymphadenopathy is usually considered as metastatic in nature, but has also been reported to be related to other conditions, including silicon migration. The purpose of this study was to determine the rate of metastatic disease in this unique group of patients. A retrospective comparative study of 12 female patients with breast cancer with silicone implants referred for biopsy due to isolated internal mammary lymph node fluorodeoxyglucose uptake on positron emission tomography. Five patients (41.6%) had histological findings related to silicone (n = 4) or non-specific inflammation (n = 1). The remaining 7 (58.3%) had histological evidence of cancer recurrence. There was no significant difference in the fluorodeoxyglucose-standardized uptake value between the two groups. Fluorodeoxyglucose-positive mammary lymph nodes in patients with breast cancer following silicone implant reconstruction may be due to metastatic deposits, non-specific inflammation or silicone migration. Clinical and imaging characteristics are insufficient in differentiating between these conditions. Biopsy is recommended prior to initiation of further treatment.

  7. Biofilm formation and design features of indwelling silicone rubber tracheoesophageal voice prostheses - An electron microscopical study

    NARCIS (Netherlands)

    Leunisse, C; van Weissenbruch, R; Busscher, HJ; van der Mei, HC; Dijk, F; Albers, FWJ

    2001-01-01

    After total laryngectomy, voice can be restored with a silicone rubber tracheoesophageal voice prosthesis. However, biofilm formation and subsequent deterioration of the silicone material of the prosthesis will limit device life by impairing valve function. To simulate the natural process of biofilm

  8. Autoimmune Syndrome Induced by Adjuvants (ASIA after Silicone Breast Augmentation Surgery

    Directory of Open Access Journals (Sweden)

    Daniel Nunes e Silva, MD

    2017-09-01

    Full Text Available Summary:. Generally, the main complications of silicone implantation are local symptoms. However, some patients develop late-onset systemic symptoms often associated with a rare form of hyperactive immune response, as part of a syndrome known as autoimmune syndrome induced by adjuvants (ASIA. Reported cases of ASIA have shown resolution with explantation, but not with immunomodulatory therapy. In this report, we described a case of a previously healthy 23-year-old woman, who has undergone silicone breast implant augmentation, for aesthetic reasons, and developed localized cutaneous impairment 3 years postsurgery. She received a diagnosis of ASIA with a new presentation: Lupus-like manifestation through localized cutaneous impairment. This patient’s symptoms were managed without the need for surgical intervention, which has not been previously reported, because the patient did not want an explantation for aesthetic reasons. The patient was started on hydroxychloroquine, 400 mg per day, and remains asymptomatic after 2 years of treatment. The exact predisposition to ASIA is still unknown. Without implant explantation and with immunomodulatory treatment, this patient’s condition substantially improved. Based on our current understanding of this disease, it might not be prudent to indicate breast augmentation with silicone implants in patients with documented autoimmune reaction to an adjuvant, an established autoimmune condition, or genetic predisposition. However, if a patient does develop silicone-induced ASIA, explantation is no longer the only successfully reported option, as these symptoms can be managed with immune suppression.

  9. Diagnostic difficulties in breast lesions after plastic operations with silicone application; Trudnosci w diagnostyce zmian sutka po operacjach plastycznych z zastosowaniem silikonu

    Energy Technology Data Exchange (ETDEWEB)

    Cieslinska-Wilk, G; Borowski, M; Slomianko-Winnicka, M [Pomorska Akademia Medyczna, Szczecin (Poland)

    1994-12-31

    Breasts of 630 women in the age 24-78 have been prophylactically examined in the years 1992-1993. The examination included mammography, ultrasonography, physical examination and fine needle aspiration cytology (FNAC) of detected lesions. There were 3 patients after plastic augmentation of the breasts with application of silicone. These patients had persistent tenderness of their breasts, inflammatory reaction, cysts or lumps. The mammograms were not evaluable because of profuse shadow of silicone. Ultrasonography has proved more useful but only in detecting of cysts. Physical examination was also difficult because of the bulky implant. Only liquid silicone was aspirated when FNAC was attempted. The authors conclude that cosmetic implantation of foreign materials into breasts should be contraindicated, especially in the group of women with elevated risk of the breast cancer. (author). 7 refs, 3 figs.

  10. Immunophenotypic characterization of human T cells after in vitro exposure to different silicone breast implant surfaces.

    Directory of Open Access Journals (Sweden)

    Giuseppe Cappellano

    Full Text Available The most common complication of silicone breast implants is capsular contracture (massive scar formation around the implant. We postulate that capsular contracture is always a sequel to inflammatory processes, with both innate and adaptive immune mechanisms participating. In general, fibroblasts and macrophages have been used as cell types to evaluate in vitro the biocompatibility of breast implant surfaces. Moreover, also T cells have been found at the implant site at the initial stage of fibrous capsule formation. However, only few studies have addressed the influence of surfaces with different textures on T-cell responses. The aim of the present study was to investigate the immune response of human peripheral blood mononuclear cells (PBMC to commercially available silicone breast implants in vitro. PBMC from healthy female blood donors were cultured on each silicone surface for 4 days. Proliferation and phenotype of cultured cells were assessed by flow cytometry. Cytokine levels were determined by multiplex and real-time assay. We found that silicone surfaces do not induce T-cell proliferation, nor do they extensively alter the proportion of T cell subsets (CD4, CD8, naïve, effector memory. Interestingly, cytokine profiling identified matrix specific differences, especially for IL-6 and TNF-α on certain surface topographies that could lead to increased fibrosis.

  11. Rehabilitation of post-traumatic total nasal defect using silicone and acrylic resin

    Directory of Open Access Journals (Sweden)

    Vikas Aggarwal

    2016-01-01

    Full Text Available Facial defects resulting from neoplasms, congenital abnormalities or trauma can affect the patient esthetically, psychologically, and even financially. Surgical reconstruction of large facial defects is sometimes not possible and frequently demands prosthetic rehabilitation. For success of such prosthesis, adequate replication of natural anatomy, color matching and blending with tissue interface are important criteria. Variety of materials and retention methods are advocated to achieve a functionally and esthetically acceptable restoration. Silicones are the most commonly used materials because of flexibility, lifelike appearance and ability to be used in combination with acrylic resin which is hard, provides body and helps in achieving retention to the prosthesis by engaging mechanical undercuts. Furthermore, the acrylic portion can be relined easily, thus helping comfortable wear and removal of the prosthesis by patient without traumatizing nasal mucosa. This case report describes time saving and cost effective prosthetic rehabilitation of a patient with total nasal defect using custom sculpted nasal prosthesis made up of silicone elastomer and acrylic resin, which is retained by engaging mechanical undercut and use of biocompatible silicone adhesive.

  12. Acute Immunologic Reaction to Silicone Breast Implant after Mastectomy and Immediate Reconstruction: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Massoome Najafi

    2014-08-01

    Full Text Available Background: Since the introduction of silicone based medical devices in to clinical practice, several reports appeared in the medical literature regarding their adverse effects. However, there are few reports of immunologic reactions to these implants.Case presentation: A case of systemic reaction to a breast implant inserted for immediate breast reconstruction in a breast cancer patient is presented. The patient developed fever and skin rash two months after the surgery. Investigations disclosed no infectious origin for the fever and a dramatic response to steroid therapy was observed.Conclusion: Immunologic reaction should be considered in case of systemic signs and symptoms after silicone breast implant placement as a rare complication. 

  13. Testicular prosthesis: Patient satisfaction and sexual dysfunctions in testis cancer survivors.

    Science.gov (United States)

    Catanzariti, Francesco; Polito, Benedetta; Polito, Massimo

    2016-10-05

    We studied patient satisfaction about sexual activity after prosthesis implantation using validated questionnaires with the aim to discover if testicular prosthesis could be responsible of sexual dysfunctions (erectile dysfunction or premature ejaculation). We evaluated a total of 67 men who underwent radical orchiectomy for testicular cancer and a silicon testicular prosthesis implantation from January 2008 to June 2014 at our Hospital. These patients completed 5 validated questionnaires the day before orchiectomy and 6 months after surgery: the International Index of Erectile Function 5 (IIEF5), the Premature Ejaculation Diagnostic Tool (PEDT), the Body Exposure during Sexual Activities Questionnaire (BESAQ), the Body-Esteem Scale and the Rosenberg Self- Esteem Scale. We also evaluated 6 months after surgery any defects of the prosthesis complained by the patients. The questionnaires completed by patients didn't show statistically significant changes for erectile dysfunction (p > 0.05) and premature ejaculation (p > 0.05). On the contrary the psychological questionnaires showed statistically significant change for the BESAQ (p < 0.001) and the Body Esteem Scale (p < 0.001), but not for the Rosenberg Self-Esteem Scale (p > 0,05). A total of 15 patients (22.37%) were dissatisfied about the prosthesis: the most frequent complaint (8 patients; 11.94%) was that the prosthesis was firmer than the normal testis. Testicular prosthesis implantation is a safe surgical procedure that should be always proposed before orchiectomy for cancer of the testis. The defects complained by patients with testicular prosthesis are few, they don't influence sexual activity and they aren't able to cause erectile dysfunction or premature ejaculation.

  14. A unique method of retaining orbital prosthesis with attachment systems - a clinical report.

    Science.gov (United States)

    Guttal, Satyabodh S; Akash, N R; Prithviraj, D R; Lekha, K

    2014-06-01

    Diminution of the orbital contents post-surgical removal of a malignant tumor can have a severe psychological impact on the patient in terms of function and esthetics. Therefore, esthetic remedy should be planned subsequently, since tumor obliteration precedes cosmetic concern. A convenient option for successful rehabilitation in such patients is a simple, user-friendly, removable orbital prosthesis. Retention of the prosthesis is one of the key factors for the successful rehabilitation. Spectacle frame, conformers, adhesives, osseointegrated implants, magnets or buttons have been used to impart retention to the prosthesis. The use of semi precision attachments in maxillofacial prostheses is limited to the osseointegrated prostheses. This case report describes a conventional spectacle frame technique, to retain the silicone orbital prosthesis using two different types of stud attachments viz., dalla bona and O-ring attachment systems. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  15. A False Positive {sup 18}F-FDG PET/CT Scan Caused by Breast Silicone Injection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chao Jung; Lee, Bi Fang; Yao, Wei Jen; Wu, Pei Shan; Chen, Wen Chung; Peng, Shu Lin; Chiu, Nan Tsing [Cheng Kung University Medical College and Hospital, Tainan (Turkmenistan)

    2009-04-15

    We present here the case of a 40-year-old woman with a greater than 10 year prior history of bilateral breast silicone injection and saline bag implantation. Bilateral palpable breast nodules were observed, but the ultrasound scan was suboptimal and the magnetic resonance imaging showed no gadolinium enhanced tumor. The {sup 18}F-FDG PET/CT scan showed a hypermetabolic nodule in the left breast with a 30% increase of {sup 18}F-FDG uptake on the delayed imaging, and this mimicked breast cancer. She underwent a left partial mastectomy and the pathology demonstrated a siliconoma.

  16. External breast prostheses. A survey of their use by women after mastectomy.

    Science.gov (United States)

    Tanner, R; Abraham, S F; Llewellyn-Jones, D

    1983-03-19

    Women who have had a mastectomy for breast cancer have to cope with two major problems: first, that they have cancer, and second, that they have lost their physical appearance. The provision of an appropriate prosthesis can reduce the sense of disfigurement. If women were to obtain the full psychological benefit of wearing a breast prosthesis, they need to be informed about the available breast forms, have an opportunity to choose between them, and to be satisfied with their choice. In this study of 49 women, only 44% had had the opportunity to choose a prosthesis, 28% were dissatisfied with their prostheses, and 17% were still using temporary prostheses.

  17. Testicular prosthesis: Patient satisfaction and sexual dysfunctions in testis cancer survivors

    Directory of Open Access Journals (Sweden)

    Francesco Catanzariti

    2016-10-01

    Full Text Available Purpose: We studied patient satisfaction about sexual activity after prosthesis implantation using validated questionnaires with the aim to discover if testicular prosthesis could be responsible of sexual dysfunctions (erectile dysfunction or premature ejaculation. Materials and Methods: We evaluated a total of 67 men who underwent radical orchiectomy for testicular cancer and a silicon testicular prosthesis implantation from January 2008 to June 2014 at our Hospital. These patients completed 5 validated questionnaires the day before orchiectomy and 6 months after surgery: the International Index of Erectile Function 5 (IIEF5, the Premature Ejaculation Diagnostic Tool (PEDT, the Body Exposure during Sexual Activities Questionnaire (BESAQ, the Body-Esteem Scale and the Rosenberg Self- Esteem Scale. We also evaluated 6 months after surgery any defects of the prosthesis complained by the patients. Results: The questionnaires completed by patients didn’t show statistically significant changes for erectile dysfunction (p > 0.05 and premature ejaculation (p > 0.05. On the contrary the psychological questionnaires showed statistically significant change for the BESAQ (p < 0.001 and the Body Esteem Scale (p < 0.001, but not for the Rosenberg Self-Esteem Scale (p > 0,05. A total of 15 patients (22.37% were dissatisfied about the prosthesis: the most frequent complaint (8 patients; 11.94% was that the prosthesis was firmer than the normal testis. Conclusions: Testicular prosthesis implantation is a safe surgical procedure that should be always proposed before orchiectomy for cancer of the testis. The defects complained by patients with testicular prosthesis are few, they don’t influence sexual activity and they aren’t able to cause erectile dysfunction or premature ejaculation.

  18. Silicone-induced granuloma of breast implant capsule (SIGBIC: similarities and differences with anaplastic large cell lymphoma (ALCL and their differential diagnosis

    Directory of Open Access Journals (Sweden)

    Fleury EF

    2017-03-01

    Full Text Available Eduardo de Faria Castro Fleury,1 Milena Morais Rêgo,1 Luciana Costa Ramalho,1 Veronica Jorge Ayres,1 Rodrigo Oliveira Seleti,2 Carlos Alberto Pecci Ferreira,2 Decio Roveda Jr 2 1Radiology Department, IBCC – Instituto Brasileiro de Controle do Câncer, 2Irmandade Santa Casa de Misericórdia de São Paulo, São Paulo, Brazil Abstract: Primary breast lymphoma is a rare disease and accounts for 0.5% of cases of breast cancer. Most primary breast lymphomas develop from B cells, and the involvement of T cells is rare. Anaplastic large cell lymphoma (ALCL is a recently discovered T-cell lymphoma associated with breast implants. Only a few cases have been reported to date. It is believed that the incidence of ALCL is increasing because of the increasing number of breast implants. The clinical presentation is variable and can manifest as a palpable mass in the breast or armpit, breast pain, or capsular contracture. Because of the rarity of the disease and the lack of knowledge to date, clinical diagnosis is often delayed, with consequent delays in treatment. The cause and pathogenesis have not been fully elucidated, and there are no evidence-based guidelines for diagnosis, treatment, or follow-up of this disease. We present a review of cases of patients with silicone breast implants, including ALCL, a rare type of breast cancer that is still under study, and silicone-induced granuloma of breast implant capsule and its differential diagnosis, and discuss if a silicone-induced granuloma of breast implant capsule could be the precursor of the disease. Keywords: lymphoma, granuloma, breast cancer, implant

  19. MR imaging of silicone breast implants: evaluation of prospective and retrospective interpretations and interobserver agreement.

    Science.gov (United States)

    Quinn, S F; Neubauer, N M; Sheley, R C; Demlow, T A; Szumowski, J

    1996-01-01

    MR imaging was used to evaluate the integrity of silicone breast implants in 54 women with 108 implants. MR images were interpreted by relatively inexperienced readers who tried to reproduce the experiences reported in the literature. The study examines the interobserver agreement using different diagnostic signs and the influence of experience on interpretation errors. Prospective and retrospective interpretations were compared with surgical findings at the time of explanation. Diagnostic indicators, including the linguine sign, the inverted tear drop sign, the C sign, water droplets mixed with silicone, and extracapsular globules of silicone, were evaluated for diagnostic efficacy and interobserver agreement. The prospective sensitivity and specificity were 87% and 78%, respectively. With the retrospective interpretations, the sensitivity and specificity increased to 93% and 92%, respectively. Most of the prospective false-positive interpretations were due to misinterpreting radial folds as signs of implant rupture. Six implants interpreted retrospectively as false positives had gross amounts of silicone around the implants at surgery but there were no obvious rents in the implant shells. There was fair to excellent interobserver agreement with the individual diagnostic signs except for extracapsular globules of silicone. All of the signs had specificities of greater than 90%. The sensitivities of the individual signs were less than the overall retrospective sensitivity. With experience, the sensitivity improved from 87% to 93% and the specificity improved from 78% to 92%. This study helps substantiate the use of diagnostic signs used by other authors to detect silicone loss from breast implants by MR imaging; however, questions remain as to the clinical role of MR imaging in evaluating implants for silicone loss.

  20. Advanced engineering tools for design and fabrication of a custom nasal prosthesis

    Science.gov (United States)

    Oliveira, Inês; Leal, Nuno; Silva, Pedro; da Costa Ferreira, A.; Neto, Rui J.; Lino, F. Jorge; Reis, Ana

    2012-09-01

    Unexpected external defects resulting from neoplasms, burns, congenital malformations, trauma or other diseases, particularly when involving partial or total loss of an external organ, can be emotionally devastating. These defects can be restored with prosthesis, obtained by different techniques, materials and methods. The increase of patient numbers and cost constraints lead to the need of exploring new techniques that can increase efficiency. The main goal of this project was to develop a full engineering-based manufacturing process to obtain soft-tissue prosthesis that could provide faster and less expensive options in the manufacturing of customized prosthesis, and at the same time being able to reproduce the highest degree of details, with the maximum comfort for the patient. Design/methodology/approach - This case report describes treatment using silicone prosthesis with an anatomic retention for an 80-years-old woman with a rhinectomy. The proposed methodology integrates non-contact structured light scanning, CT and reverse engineering with CAD/CAM and additive manufacturing technology. Findings - The proposed protocol showed encouraging results since reveals being a better solution for fabricating custom-made facial prostheses for asymmetrical organs than conventional approaches. The process allows the attainment of prosthesis with the minimum contact and discomfort for the patient, disclosing excellent results in terms of aesthetic, prosthesis retention and in terms of time and resources consumed.

  1. Impact of scintimammography in management of breast cancer ...

    African Journals Online (AJOL)

    Mammography is the most widely used diagnostic imaging method for screening and diagnosing breast cancer. Nevertheless, this technique has some limitations in that not all breast cancers are evident on mammograms, especially in dense or dysplastic breasts, patients with breast prosthesis or if the patient has ...

  2. Systemic Sclerosis and Silicone Breast Implant: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Antonios Psarras

    2014-01-01

    Full Text Available Environmentally induced systemic sclerosis is a well-recognized condition, which is correlated with exposure to various chemical compounds or drugs. However, development of scleroderma-like disease after exposure to silicone has always been a controversial issue and, over time, it has triggered spirited debate whether there is a certain association or not. Herein, we report the case of a 35-year-old female who developed Raynaud’s phenomenon and, finally, systemic sclerosis shortly after silicone breast implantation surgery.

  3. ALK-1-negative anaplastic large cell lymphoma associated with breast implants: a new clinical entity.

    Science.gov (United States)

    Lazzeri, Davide; Agostini, Tommaso; Bocci, Guido; Giannotti, Giordano; Fanelli, Giovanni; Naccarato, Antonio Giuseppe; Danesi, Romano; Tuccori, Marco; Pantaloni, Marcello; D'Aniello, Carlo

    2011-10-01

    Concerns have been raised recently regarding the increasing number of reports of non-Hodgkin lymphoma (NHL) that developed in close proximity to silicone or saline breast implants. In particular, an increased risk of anaplastic large cell lymphoma (ALCL) in patients with breast prostheses has been proposed. We reviewed clinical and pathologic findings in 40 women who received a diagnosis of breast NHL arising in association with breast implants and of 27 patients who had a diagnosis of ALCL with breast involvement reported in the published literature. Among the 40 reported cases of prosthesis-associated breast lymphomas, 28 were anaplastic lymphoma kinase-1-negative (ALK-1(-)) ALCLs, whereas of 27 ALCLs in patients without implants found in the literature, only 10 were ALK-1(-). The finding of 28 cases of breast ALK-1(-) ALCL occurring in patients with implants compared with 10 cases in women without implants is in favor of an association between silicone breast prostheses and ALK-1(-) ALCL. Although the incidence of this type of lymphoma remains remarkably low given that breast prostheses have been widely used for decades, clinical and pathologic evidence for a causative role is becoming dramatically strong. The histologic, phenomenologic, and clinical similarities of the majority of implant-related ALK-1(-) ALCLs suggest a common mechanism, especially when compared with the counterpart of patients without implants in which very few and highly dishomogeneous cases of the same malignancy were detected. There is convincing evidence that primary implant-related ALK-1(-) ALCL represents a distinct clinicopathologic entity that has been inappropriately fitted into the category of systemic ALK-1(-) ALCL. Thus it should be recognized as a separate category and classified on its own. Copyright © 2011 Elsevier Inc. All rights reserved.

  4. A prospective study on silicone breast implants and the silicone-related symptom complex.

    Science.gov (United States)

    Contant, C M E; Swaak, A J G; Obdeijn, A I M; van der Holt, B; Tjong Joe Wai, R; van Geel, A N; Eggermont, A M M

    2002-06-01

    This cohort study prospectively evaluated the prevalence of the silicone-related symptom complex (SRSC) in relation to antinuclear antibodies (ANA) and magnetic resonance imaging (MRI) of silicone breast implants (SBI) 1 year after implantation. A total of 57 women undergoing mastectomy followed by immediate breast reconstruction (IBR) and SBI between March 1995 and March 1997 at the University Hospital Rotterdam/Daniel den Hoed Cancer Centre, were prospectively evaluated. Just before and 1 year after IBR the sera of these women were tested for the presence of ANA and they were screened for the prevalence of SRSC-related symptoms by questionnaire. All prostheses were evaluated by MRI 1 month and 1 year after IBR. Just before operation 11% of the women had a Sjögren score of more than 2, whereas 30% had such a score 1 year after IBR ( P = 0.01). One year postoperatively women had significantly more RA/Raynaud-related complaints: 21% preoperatively versus 40% 1 year after IBR ( P = 0.03). Within the undefined complaints-related group 19% had a score of 2 or more preoperatively and 33% 1 year after IBR ( P = 0.09). There were no new cases of ANA positivity 1 year after IBR. The linguine sign was seen by MRI in three implants: one 1 month after IBR and two 1 year after IBR. There was no relation to changes in SRSC expression and these MRI findings. In conclusion, 1 year after SBI implantation women had more SRSC-related complaints, especially Sjögren's and RA/Raynaud's. Moreover there was no correlation between elevated SRSC expression and changes in the presence of ANA or changes in MRI of the SBI 1 year after IBR.

  5. Breast Augmentation

    African Journals Online (AJOL)

    1974-04-13

    Apr 13, 1974 ... Complications encountered after breast augmentation are dealt with in .... in Phisohex or other suitable preparation for a few days before surgery ... In all cases, the prosthesis causes a fibrous tissue capsule to form around it.

  6. Axillary lymph nodes siliconoma in a woman with intracapsular implant rupture

    International Nuclear Information System (INIS)

    Plachkov, I.; Cvetankov, K.; Hadjidekov, G.

    2013-01-01

    Full text: Introduction: Siliconoma, or silicone granuloma is the migration of silicon particles in the axillary lymph nodes, muscle and other non- ruptured or intact silicone implant. The latter is a relatively rare finding, and usually occurs in patients with extracapsular rupture of silicone prosthesis and has a typical ultrasound image. We present a case of a young woman with bilateral silicone prostheses placed 5 years ago, where in the right axilla are enlarged, structurally altered lymph nodes in the clinical and ultrasonography studies. Subsequent magnetic resonance examination shows intracapsular rupture ipsilateral silicone prosthesis and migration of silicon particles in the axillary lymph nodes. What you will learn: In this case we present twenty-three year old woman who reported pain and ‘swelling’ in the right axilla. The patient is with bilateral silicone prosthesis, she is not febrile and not reported other illness. After physical examination enlarged and tender lymph nodes in the right axilla was found. Several structurally altered and enlarged lymph nodes were visualized by ultrasound. These lymph nodes are hypoechogenic with obliterated fatty hilus. Due to the suspicion of silicone ‘extravasation’ in axillary lymph nodes, a magnetic resonance study of both mammary glands was performed. The images show intracapsular rupture of the right prosthesis without reliable data on silicone gel outside the fibrous capsule. Discussion: Siliconoma is a complication after plastic surgery of the breast and can affect both the axillary lymph nodes, and other lymphatic chains and also muscle and lung. Most frequently it occurs at damage of the extracapsular silicone prostheses. More rarely siliconoma occurs in siliconoma intracapsular damage, as in the presented case or in a silicone gel microbleed. Conclusion: The presence of siliconoma in axillary lymph nodes is relatively rare complication in plastic surgery of the breast. Methods of imaging diagnostic

  7. Breast radiation - discharge

    Science.gov (United States)

    ... underwire. Ask your provider about wearing your breast prosthesis, if you have one. Self-care You need ... swelling ( edema ) in your arm. You have a feeling of tightness in your arm. Rings on your ...

  8. Amine-modified hyaluronic acid-functionalized porous silicon nanoparticles for targeting breast cancer tumors

    Science.gov (United States)

    Almeida, Patrick V.; Shahbazi, Mohammad-Ali; Mäkilä, Ermei; Kaasalainen, Martti; Salonen, Jarno; Hirvonen, Jouni; Santos, Hélder A.

    2014-08-01

    Active targeting of nanoparticles to receptor-overexpressing cancer cells has great potential for enhancing the cellular uptake of nanoparticles and for reducing fast clearance of the nanoparticles from the body. Herein, we present a preparation method of a porous silicon (PSi)-based nanodelivery system for breast cancer targeting, by covalently conjugating a synthesized amide-modified hyaluronic acid (HA+) derived polymer on the surface of undecylenic acid-modified thermally hydrocarbonized PSi (UnTHCPSi) nanoparticles. The resulting UnTHCPSi-HA+ nanoparticles showed relatively small size, reduced polydispersibility, high biocompatibility, improved colloidal and human plasma stability, as well as enhanced cellular interactions and internalization. Moreover, we demonstrated that the enhanced cellular association of UnTHCPSi-HA+ relies on the capability of the conjugated HA+ to bind and consequently target CD44 receptors expressed on the surface of breast cancer cells, thus making the HA+-functionalized UnTHCPSi nanoparticles a suitable and promising nanoplatform for the targeting of CD44-overexpressing breast tumors and for drug delivery.Active targeting of nanoparticles to receptor-overexpressing cancer cells has great potential for enhancing the cellular uptake of nanoparticles and for reducing fast clearance of the nanoparticles from the body. Herein, we present a preparation method of a porous silicon (PSi)-based nanodelivery system for breast cancer targeting, by covalently conjugating a synthesized amide-modified hyaluronic acid (HA+) derived polymer on the surface of undecylenic acid-modified thermally hydrocarbonized PSi (UnTHCPSi) nanoparticles. The resulting UnTHCPSi-HA+ nanoparticles showed relatively small size, reduced polydispersibility, high biocompatibility, improved colloidal and human plasma stability, as well as enhanced cellular interactions and internalization. Moreover, we demonstrated that the enhanced cellular association of Un

  9. Single- and double- lumen silicone breast implant integrity: prospective evaluation of MR and US criteria.

    Science.gov (United States)

    Berg, W A; Caskey, C I; Hamper, U M; Kuhlman, J E; Anderson, N D; Chang, B W; Sheth, S; Zerhouni, E A

    1995-10-01

    To evaluate the accuracy of magnetic resonance (MR) and ultrasound (US) criteria for breast implant integrity. One hundred twenty-two single-lumen silicone breast implants and 22 bilumen implants were evaluated with surface coil MR imaging and US and surgically removed. MR criteria for implant failure were a collapsed implant shell ("linguine sign"), foci of silicone outside the shell ("noose sign"), and extracapsular gel, US criteria were collapsed shell, low-level echoes within the gel, and "snowstorm" echoes of extracapsular silicone. Among single-lumen implants, MR imaging depicted 39 of 40 ruptures, 14 of 28 with minimal leakage; 49 of 54 intact implants were correctly interpreted. US depicted 26 of 40 ruptured implants, four of 28 with minimal leakage, and 30 of 54 intact implants. Among bilumen implants, MR imaging depicted four of five implants with rupture of both lumina and nine of 10 as intact; US depicted one rupture and helped identify two of 10 as intact. Mammography accurately depicted the status of 29 of 30 bilumen implants with MR imaging correlation. MR imaging depicts implant integrity more accurately than US; neither method reliably depicts minimal leakage with shell collapse. Mammography is useful in screening bilumen implant integrity.

  10. Complex radiological diagnosis of a breast cancer at women after augmentation mammоplasty of silicone gel implants

    Directory of Open Access Journals (Sweden)

    T. A. Shumakova

    2014-01-01

    Full Text Available One of leading problems of mammology is early diagnostics of a breast cancer. The work purpose studying of opportunities of a complex of radiological research techniques in diagnostics of a breast cancer at women after augmentation mammoplasty silicone gel implants. By results of сomplex kliniko-radiological examination of 630 women aged from 18 till 72 years (middle age made 35 ± 0.43 years with 1260 implants the breast cancer was revealed at 7 (1.1 % patients. The invasive pro-current cancer with local widespread type of body height of tumoral knot is histologically diagnosed. Sensitivity and specificity of methods of radiodiagnosis in identification of a cancer of mammary glands at women after endoprosthesis replacement made mammography – 28.6 % and 66.1 %, ultrasonography – 71.4 % and 85.7 %, magnetic resonance imaging – 85.7 % and 98.2 %, respectively. Thus, complex application of radiology research techniques raises level of diagnostics of breast cancer at patients after augmentation mammoplasty silicone gel implants that allows to choose an adequate method of treatment.

  11. Engagement in activities revealing the body and psychosocial adjustment in adults with a trans-tibial prosthesis.

    Science.gov (United States)

    Donovan-Hall, M K; Yardley, L; Watts, R J

    2002-04-01

    The purpose of this study was to examine the effects of the appearance of a prosthesis on social behaviour, social discomfort and psychological well-being in eleven amputees taking delivery of a prosthesis with a silicone cover. Two new scales were developed: the 'Engagement in everyday activities involving revealing the body' (EEARB); and the 'Discomfort-Engagement in everyday activities involving revealing the body' (Discomfort-EEARB) scales. The psychometric properties of these scales were determined using a sample of 101 able-bodied adults. The Hospital Anxiety and Depression Scale and the Rosenberg Self-Esteem Scale were also used to measure psychological well-being in the amputee sample. The EEARB and Discomfort-EEARB proved to have good reliability and validity. Comparison of amputees' scores prior to receiving the silicone cosmesis with those of the able-bodied adults revealed significant behavioural limitations and social discomfort, associated with low self-esteem, anxiety and depression. There was a significant increase in amputees' scores three months afier taking delivery of their prosthesis, indicating that amputees reported engaging in more activities which involved revealing their body, and that they would feel more comfortable in situations which involved revealing the body. As the amputee sample available was small and self-selected, it is not possible to generalise these findings to the amputee population as a whole. However, since there is little previous research investigating the effects of the appearance of the prosthesis, these findings demonstrate the need for further research in this area.

  12. Correlation between MRI results and intraoperative findings in patients with silicone breast implants

    Directory of Open Access Journals (Sweden)

    Lindenblatt N

    2014-07-01

    Full Text Available Nicole Lindenblatt,1 Karem El-Rabadi,2 Thomas H Helbich,2 Heinrich Czembirek,3 Maria Deutinger,4 Heike Benditte-Klepetko5 1Division of Plastic and Hand Surgery, Department of Surgery, University Hospital Zurich, Zurich, Switzerland; 2Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Medical University of Vienna - General Hospital Vienna, 3Department of Radiology, Hospital Wiener Privatklinik, 4Department of Plastic and Reconstructive Surgery, Hospital Rudolfstiftung, Vienna, Austria; 5Department of Plastic and Reconstructive Surgery, Erasmus Medical Center, Rotterdam, the Netherlands Background: Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. Methods: Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the patients was 51 (range 21–72 years, with a mean duration of implantation of 3.8 (range 1–28 years. All patients underwent clinical examination and breast MRI. Intraoperative implant rupture was diagnosed by the operating surgeon. Results: Nineteen of the 50 patients suffered from clinical symptoms. An implant rupture was diagnosed by MRI in 22 of 85 implants (26%. In seven of 17 removed implants (41%, the intraoperative diagnosis corresponded with the positive MRI result. However, only 57% of these patients were symptomatic. Ultrasound imaging of the harvested implants showed signs of interrupted inner layers of the implant despite integrity of the outer shell. By microsurgical separation of the different layers of the implant shell, we were able to reproduce this phenomenon and to produce signs of implant rupture on MRI. Conclusion: Our results show that rupture of only the inner layers of the implant shell with integrity of

  13. Correlation between MRI results and intraoperative findings in patients with silicone breast implants.

    Science.gov (United States)

    Lindenblatt, Nicole; El-Rabadi, Karem; Helbich, Thomas H; Czembirek, Heinrich; Deutinger, Maria; Benditte-Klepetko, Heike

    2014-01-01

    Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the patients was 51 (range 21-72) years, with a mean duration of implantation of 3.8 (range 1-28) years. All patients underwent clinical examination and breast MRI. Intraoperative implant rupture was diagnosed by the operating surgeon. Nineteen of the 50 patients suffered from clinical symptoms. An implant rupture was diagnosed by MRI in 22 of 85 implants (26%). In seven of 17 removed implants (41%), the intraoperative diagnosis corresponded with the positive MRI result. However, only 57% of these patients were symptomatic. Ultrasound imaging of the harvested implants showed signs of interrupted inner layers of the implant despite integrity of the outer shell. By microsurgical separation of the different layers of the implant shell, we were able to reproduce this phenomenon and to produce signs of implant rupture on MRI. Our results show that rupture of only the inner layers of the implant shell with integrity of the outer shell leads to a misdiagnosis on MRI. Correlation with clinical symptoms and the specific wishes of the patient should guide the indication for implant removal.

  14. Systematic review of the effectiveness of polyurethane-coated compared with textured silicone implants in breast surgery.

    Science.gov (United States)

    Duxbury, Paula J; Harvey, James R

    2016-04-01

    Silicone gel implants are used worldwide for breast augmentation and breast reconstruction. Textured silicone implants are the most commonly placed implant, but polyurethane-coated implants are increasingly being used in an attempt to ameliorate the long-term complications associated with implant insertion. This systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Electronic searches of MEDLINE, EMBASE, the Cochrane Library and www.ClinicalTrials.gov were undertaken in March 2014 using keywords. Following data extraction, 18 studies were included in the review, including four core studies of textured silicone implants and five studies reporting outcomes for polyurethane-coated silicone implants. There are no clear data reporting revision rates in patients treated with polyurethane implants. In the primary reconstructive setting, capsular contracture rates with silicone implants are 10-15% at 6 years, whilst studies of polyurethane implants report rates of 1.8-3.4%. In the primary augmentation setting, core studies show a capsular contracture rate of 2-15% at 6 years compared with 0.4-1% in polyurethane-coated implants; however, the polyurethane studies are limited by their design and poor follow-up. The use of polyurethane implants should be considered a safe alternative to textured silicone implants. It is likely that an implant surface does influence short- and long-term outcomes; however, the extent of any benefit cannot be determined from the available evidence base. Future implant studies should target the short- and long-term benefits of implant surfacing by procedure with defined outcome measures; a head-to-head comparison would help clarify outcomes. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  15. Use of digital technologies for nasal prosthesis manufacturing.

    Science.gov (United States)

    Palousek, David; Rosicky, Jiri; Koutny, Daniel

    2014-04-01

    Digital technology is becoming more accessible for common use in medical applications; however, their expansion in prosthetic and orthotic laboratories is not large because of the persistent image of difficult applicability to real patients. This article aims to offer real example in the area of human facial prostheses. This article describes the utilization of optical digitization, computational modelling, rapid prototyping, mould fabrication and manufacturing of a nasal silicone prosthesis. This technical note defines the key points of the methodology and aspires to contribute to the introduction of a certified manufacturing procedure. The results show that the used technologies reduce the manufacturing time, reflect patient's requirements and allow the manufacture of high-quality prostheses for missing facial asymmetric parts. The methodology provides a good position for further development issues and is usable for clinical practice. Clinical relevance Utilization of digital technologies in facial prosthesis manufacturing process can be a good contribution for higher patient comfort and higher production efficiency but with higher initial investment and demands for experience with software tools.

  16. Value of contrast-enhanced MRI of breast after silicone implant

    International Nuclear Information System (INIS)

    Heinig, A.; Heywang-Koebrunner, S.H.; Viehweg, P.; Spielmann, R.P.; Lampe, D.; Buchmann, J.

    1997-01-01

    Early recognition of recurrence and work-up of clinically indeterminate lesions may be impaired after reconstruction with silicone implants due to superimposition of the implant or to scarring. This study was undertaken to evaluate the use of contrast-enhanced MRI in patients with silicone implant after breast cancer. Contrast-enhanded MRI was offered to 169 patients. Comparative two- to three-view mammography was also performed in 169 patients, as well as comparative sonography in 144 patients. Conventional imaging and clinical examination detected only 8/13 recurrences, whereas 12/13 were detected by MRI. One recurrence had been visible as a strongly enhancing 2-mm dot in a previous examination (2 years before), but was not called. It was therefore counted as false negative. In addition, multicentricity was detected by MRI alone in two of three cases. MRI correctly diagnosed scar tissue in all cases with indeterminate findings. However, due to false-positive calls caused by enhancing granulomas specificity could not be improved. Contrast-enhanded MRI allowed decisive additional information in our study group and improved the sensitivity significantly (concerning all diagnoses). Contrast-enhanded MRI allowed decisive additional information in our study group and improved the sensitivity significantly (concerning all diagnoses). Contrast-enhanded MRI is recommended in patients with diagnostic problems or high risk of recurrence after silicone implants. (orig.) [de

  17. Incidence of Internal Mammary Lymph Nodes with Silicone Breast Implants at MR Imaging after Oncoplastic Surgery.

    Science.gov (United States)

    Sutton, Elizabeth J; Watson, Elizabeth J; Gibbons, Girard; Goldman, Debra A; Moskowitz, Chaya S; Jochelson, Maxine S; Dershaw, D David; Morris, Elizabeth A

    2015-11-01

    To assess the incidence of benign and malignant internal mammary lymph nodes (IMLNs) at magnetic resonance (MR) imaging among women with a history of treated breast cancer and silicone implant reconstruction. The institutional review board approved this HIPAA-compliant retrospective study and waived informed consent. Women were identified who (a) had breast cancer, (b) underwent silicone implant oncoplastic surgery, and (c) underwent postoperative implant-protocol MR imaging with or without positron emission tomography (PET)/computed tomography (CT) between 2000 and 2013. The largest IMLNs were measured. A benign IMLN was pathologically proven or defined as showing 1 year of imaging stability and/or no clinical evidence of disease. Malignant IMLNs were pathologically proven. Incidence of IMLN and positive predictive value (PPV) were calculated on a per-patient level by using proportions and exact 95% confidence intervals (CIs). The Wilcoxon rank sum test was used to assess the difference in axis size. In total, 923 women with breast cancer and silicone implants were included (median age, 46 years; range, 22-89 years). The median time between reconstructive surgery and first MR imaging examination was 49 months (range, 5-513 months). Of the 923 women, 347 (37.6%) had IMLNs at MR imaging. Median short- and long-axis measurements were 0.40 cm (range, 0.20-1.70 cm) and 0.70 cm (range, 0.30-1.90 cm), respectively. Two hundred seven of 923 patients (22.4%) had adequate follow-up; only one of the 207 IMLNs was malignant, with a PPV of 0.005 (95% CI: 0.000, 0.027). Fifty-eight of 923 patients (6.3%) had undergone PET/CT; of these, 39 (67.2%) had IMLN at MR imaging. Twelve of the 58 patients (20.7%) with adequate follow-up had fluorine 18 fluorodeoxyglucose-avid IMLN, with a median standardized uptake value of 2.30 (range, 1.20-6.10). Only one of the 12 of the fluorodeoxyglucose-avid IMLNs was malignant, with a PPV of 0.083 (95% CI: 0.002, 0.385). IMLNs identified at

  18. MR images of rupture and leakage of breast implants

    International Nuclear Information System (INIS)

    Fang Ling; Liu Pengcheng; Huang Rong; Hu Huaxin; Chen Zaizhong; Du Duanming; Liu Hanqiao; Feng Fei

    2002-01-01

    Objective: To investigate the diagnostic value of magnetic resonance imaging in detecting rupture and leakage of breast implants. Methods: Seventeen cases with breast implants were imaged by MR scanner. 1 normal silicone breast implant outside the body was scanned by MR as an consultative standard. MR images of silicone implants and polypropylene acyl amine implants were classified and analyzed. Results: In 7 cases, 12 single lumen silicone implants were intact, among them 8 were silicone gel-filled implants, 4 were physiological saline-filled implants. 2 physiological saline-filled implants ruptured, among them 1 belonged to intracapsular silicone implant rupture with subsided silicone gel capsule which presented as long T 1 signal and short T 2 signal on MR images; The other belonged to extracapsular silicone implant rapture with physiological saline granule outside breast on MR images. 20 breast implants in 10 cases were injected by polypropylene acyl amine, among them 2 breast implants were intact, 16 breast implants ruptured completely with pieces and nodes of long T 1 signal and long T 2 signal on MR images, 14 of 16 also presented polypropylene acyl amine granule outside breast; 2 breast implants splited inside with linguine sign. Conclusion: The magnetic resonance imaging can make clear the type and the seat of breast implants, the type of rupture of breast implants, and the distribution of leakage material. Therefore magnetic resonance imaging can be an effective guidance for clinical operation and can be an consultative standard for follow-up

  19. The evolution of FDA policy on silicone breast implants: a case study of politics, bureaucracy, and business in the process of decision-making.

    Science.gov (United States)

    Palley, H A

    1995-01-01

    The central issue facing federal regulation of breast implants is that while such devices are not functionally necessary or needed for survival, the side effects may be harmful and have not been proven unharmful. The Medical Device Amendments of 1976 appear to require such evidence prior to the FDA permitting the unrestricted marketing of these devices. However, only recently have such requirements been imposed by the FDA. The author examines the FDA's decision-making process, particularly as applied to silicone breast implants, and the factors that appears to have affected such decisions. In pursuing this study, the activities of a number of interest-group actors, as well as congressional responses and the role of federal bureaucratic actors, were examined. In 1992, the FDA established a regulatory protocol that effectively withdrew most silicone breast implants from the market for the purpose of breast augmentation and allows for the monitoring of the impact of new implants on women's health. This increase concern for determining the safety of breast implants is due to a number of factors, which are examined in this article.

  20. Mastectomy and breast reconstruction - what to ask your doctor

    Science.gov (United States)

    ... I have a nipple also? Will I have feeling in my new breast? What are the risks of each type of breast reconstruction? If I do not have reconstruction, what are my options? Can I wear a prosthesis? How can I get my home ready before ...

  1. Robotic lower limb prosthesis design through simultaneous computer optimizations of human and prosthesis costs

    Science.gov (United States)

    Handford, Matthew L.; Srinivasan, Manoj

    2016-02-01

    Robotic lower limb prostheses can improve the quality of life for amputees. Development of such devices, currently dominated by long prototyping periods, could be sped up by predictive simulations. In contrast to some amputee simulations which track experimentally determined non-amputee walking kinematics, here, we explicitly model the human-prosthesis interaction to produce a prediction of the user’s walking kinematics. We obtain simulations of an amputee using an ankle-foot prosthesis by simultaneously optimizing human movements and prosthesis actuation, minimizing a weighted sum of human metabolic and prosthesis costs. The resulting Pareto optimal solutions predict that increasing prosthesis energy cost, decreasing prosthesis mass, and allowing asymmetric gaits all decrease human metabolic rate for a given speed and alter human kinematics. The metabolic rates increase monotonically with speed. Remarkably, by performing an analogous optimization for a non-amputee human, we predict that an amputee walking with an appropriately optimized robotic prosthesis can have a lower metabolic cost - even lower than assuming that the non-amputee’s ankle torques are cost-free.

  2. RIB FRACTURE AFTER BREAST RECONSTRUCTION WITH TISSUE EXPANDER

    Directory of Open Access Journals (Sweden)

    Uroš Ahčan

    2009-08-01

    Full Text Available Breast reconstruction with tissue expansion and later exchange with prosthesis is one of the most common methods for breast reconstruction. Women that are not appropriate for reconstruction with autologous tissue, women that have small breast or have a positive family history for breast cancer are most suitable for this type of reconstruction. Surgical technique of tissue expansion is relatively easy. Complications are rarely seen. With this case report we want to show the common, although occult existence of skeletal deformities in thorax after breast tissue expansion that may lead to rib fractures.

  3. Magnetic resonance imaging of breast prostheses

    African Journals Online (AJOL)

    G5

    and the commonest cause of replacement of the prosthesis. Older prostheses contained silicone gel. Rupture of these prostheses, although asymptomatic in most patients, has been associated with collagen vascular disorders and chronic fatigue syndrome. However more current data disputes any of these associations.

  4. Rehabilitation with ear prosthesis linked to osseointegrated implants.

    Science.gov (United States)

    Goiato, Marcelo C; dos Santos, Daniela M; Haddad, Marcela F; Moreno, Amália

    2012-06-01

    The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment. The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants. The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system. The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem. © 2012 The Gerodontology Society and John Wiley & Sons A/S.

  5. Three-dimensional imaging, an important factor of decision in breast augmentation.

    Science.gov (United States)

    de Runz, A; Boccara, D; Bertheuil, N; Claudot, F; Brix, M; Simon, E

    2018-04-01

    Since the beginning of the 21st century, three-dimensional imaging systems have been used more often in plastic surgery, especially during preoperative planning for breast surgery and to simulate the postoperative appearance of the implant in the patient's body. The main objective of this study is to assess the patients' attitudes regarding 3D simulation for breast augmentation. A study was conducted, which included women who were operated on for primary breast augmentation. During the consultation, a three-dimensional simulation with Crisalix was done and different sized implants were fitted in the bra. Thirty-eight women were included. The median age was 29.4, and the median prosthesis volume was 310mL. The median rank given regarding the final result was 9 (IQR: 8-9). Ninety percent of patients agreed (66% absolutely agreed, and 24% partially agreed) that the final product after breast augmentations was similar to the Crisalix simulation. Ninety-three percent of the patients believed that the three-dimensional simulation helped them choose their prosthesis (61% a lot and 32% a little). After envisaging a breast enlargement, patients estimated that the Crisalix system was absolutely necessary (21%), very useful (32%), useful (45%), or unnecessary (3%). Regarding prosthesis choice, an equal number of women preferred the 3D simulation (19 patients) as preferred using different sizes of implants in the bra (19 patients). The present study demonstrated that 3D simulation is actually useful for patients in order to envisage a breast augmentation. But it should be used as a complement to the classic method of trying different sized breast implants in the bra. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  6. Comparison of orbital prosthesis motility following enucleation or evisceration with sclerotomy with or without a motility coupling post in dogs.

    Science.gov (United States)

    Yi, Na Young; Park, Shin Ae; Jeong, Man Bok; Kim, Won Tae; Kim, Se Eun; Kim, Ji Youn; Chae, Je Min; Jang, Kyoung Jin; Seong, Je Kyung; Seo, Kang Moon

    2009-01-01

    To evaluate motility of silicone orbital implants and corneoscleral prostheses, with and without use of a motility coupling post (MCP) in dogs. Eighteen mixed-breed dogs. The motility of an orbital silicone implant and corneoscleral prosthesis after enucleation (n = 6), evisceration (n = 6), or use of a MCP with evisceration (n = 6) in dogs were compared. One eye from each dog had surgery whereas the opposite eye was used as a control. Clinical evaluations were performed three times a week. Histopathology of the orbital tissues was performed 8 and 12 weeks after surgery. Implant motility in dogs with evisceration (vertical movement [VM] 8.04 +/- 2.13; horizontal movement [HM] 11 +/- 3.05) and evisceration with MCP (VM 9.61 +/- 1.59); HM was significantly greater than the enucleation group (VM 0.51 +/- 0.5; HM 1.22 +/- 0.68) (P dogs with evisceration with MCP was significantly greater than in dogs with evisceration; dogs with evisceration had significantly greater motility than dogs with enucleation (P dogs. This study supports the use of MCP in silicone orbital implants to enhance corneoscleral prosthesis motility and cosmetics in dogs.

  7. Localized morphea after breast implant for breast cancer: A case report.

    Science.gov (United States)

    Moretti, A; Bianchi, F; Abbate, I V; Gherardi, G; Bonavita, M; Passoni, E; Nazzaro, G; Bramati, A; Dazzani, M C; Piva, S; Paternò, E; Frungillo, N; Farina, G; La Verde, N

    2018-03-01

    Early breast cancer follow-up guidelines for patients who underwent surgery suggest a regular and accurate clinical examination of the breast area, for an early identification of cutaneous or subcutaneous breast cancer relapse. Nonetheless, breast skin lesions arising in patients treated with mastectomy for breast cancer can be caused by several diseases. A series of diagnostic hypotheses should be considered, not only focusing on cutaneous metastasis, but also on dermatologic and systemic diseases. In February 2015, a 37-year-old patient underwent a right subcutaneous mastectomy for stage IIA breast cancer. Five months after beginning adjuvant chemotherapy, she noted hyperpigmentation and thickening of the skin on the right breast. Differential diagnosis included local relapse, skin infection, lymphoma, or primary cutaneous disease, and a skin biopsy was performed. The histopathologic specimen showed full-thickness sclerosis, with features of localized morphea. Therapy with clobetasol was prescribed, with progressive resolution of the thickness. The collaboration between many professionals in a multidisciplinary team (oncologist, dermatologist, plastic surgeon, and pathologist) was crucial to achieving the diagnosis. In the literature, some articles describe correlation between connective tissue diseases and silicone breast implants, but the pathogenetic mechanisms are unknown. We report a rare case of breast morphea after positioning a silicone implant in a patient who had undergone mastectomy. This clinical report represents an interesting model of multidisciplinary management of a patient with breast cancer who developed an uncommon dermatologic disease. Further studies are needed to clarify the association between silicone implants and breast morphea.

  8. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    Energy Technology Data Exchange (ETDEWEB)

    Maijers, M.C.; Ritt, M.J.P.F. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Niessen, F.B. [VU University Medical Centre, Department of Plastic, Reconstructive and Hand Surgery, De Boelelaan 1117, PO Box 7057, Amsterdam (Netherlands); Jan van Goyen Clinic, Department of Plastic Surgery, Amsterdam (Netherlands); Veldhuizen, J.F.H. [MRI Centre, Amsterdam (Netherlands); Manoliu, R.A. [MRI Centre, Amsterdam (Netherlands); VU University Medical Centre, Department of Radiology, Amsterdam (Netherlands)

    2014-06-15

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  9. MRI screening for silicone breast implant rupture: accuracy, inter- and intraobserver variability using explantation results as reference standard

    International Nuclear Information System (INIS)

    Maijers, M.C.; Ritt, M.J.P.F.; Niessen, F.B.; Veldhuizen, J.F.H.; Manoliu, R.A.

    2014-01-01

    The recall of Poly Implant Prothese (PIP) silicone breast implants in 2010 resulted in large numbers of asymptomatic women with implants who underwent magnetic resonance imaging (MRI) screening. This study's aim was to assess the accuracy and interobserver variability of MRI screening in the detection of rupture and extracapsular silicone leakage. A prospective study included 107 women with 214 PIP implants who underwent explantation preceded by MRI. In 2013, two radiologists blinded for previous MRI findings or outcome at surgery, independently re-evaluated all MRI examinations. A structured protocol described the MRI findings. The ex vivo findings served as reference standard. In 208 of the 214 explanted prostheses, radiologists agreed independently about the condition of the implants. In five of the six cases they disagreed (2.6 %), but subsequently reached consensus. A sensitivity of 93 %, specificity of 93 %, positive predictive value of 77 % and negative predictive value of 98 % was found. The interobserver agreement was excellent (kappa value of 0.92). MRI has a high accuracy in diagnosing rupture in silicone breast implants. Considering the high kappa value of interobserver agreement, MRI appears to be a consistent diagnostic test. A simple, uniform classification, may improve communication between radiologist and plastic surgeon. (orig.)

  10. The Angelchik prosthesis

    International Nuclear Information System (INIS)

    Fargnoli, R.; Bozza, A.; Magnoli, A.; Villari, N.; Pernice, L.M.; Andreoli, F.; Lombardi, P.

    1989-01-01

    The Angelchik prosthesis is used in the surgical treatment of gastroesophageal reflux. Operated patients are preliminary examined with imaging techniques, but manometric and acidometric techniques are also used. Although the conventional esophagogram still maintains its diagnostic significance, Computed Tomography (CT) has become the first-choice imaging modality. CT allows the correct evaluation of both the state of the prosthesis and its relationship to the esophagus and gastric fundus. The possible postoperative complications following an incorrect placement of the prosthesis can be accurately diagnosed too. The authors report their experience in the study of 5 patients examined with both conventional radiology and CT

  11. What's really behind the attack on silicone breast implants.

    Science.gov (United States)

    Angell, M

    1996-09-09

    Millions of dollars are being awarded by injuries and a major company has been forced into bankruptcy because of litigation over silicone breast implants. Yet scientific research hasn't established a link between the implants and disease, notes Marcia Angell, executive editor of the New England Journal of Medicine. When she began studying the issue, this self-described feminist and liberal Democrat expected to uncover iniquities of big business and the implant manufacturers. Instead, she's written an indictment of the tort system, junk science, and the gullibility of the news media. Attorneys have twisted facts and played on the emotions of juries, with the consent of judges and often to the cheers of the press. Angell worries that it's now become politically correct to bash the scientific method in the name of diversity, multiculturalism, and feminism.

  12. The Clinical and Diagnostic Consequences of Poly Implant Prothese Silicone Breast Implants, Recalled from the European Market in 2010

    NARCIS (Netherlands)

    Maijers, M.C.; Niessen, F.B.

    2013-01-01

    BACKGROUND:: Recently, Poly Implant Prothèse silicone breast implants were recalled from the European market. The authors studied 112 women and previously published data on rupture prevalence. Women are presenting with symptoms they feel may be a result of ruptured implants. The authors' aim was to

  13. [A scanning electron microscopy study of the surface of porous-textured breast implants and their capsules. Description of the "velcro" effect of porous-textured breast prostheses].

    Science.gov (United States)

    Danino, A; Rocher, F; Blanchet-Bardon, C; Revol, M; Servant, J M

    2001-02-01

    The efficacy of breast prosthesis texturing in the prevention of capsular contracture has been established for about 20 years. This successful procedure has led to the development and marketing of a number of different models. In the present study, four porous-textured breast prostheses have been examined: the Arion monoblock implant, the CUI (McGahn), the Biocell (Mcgahn), and the Sebbin LS21. Scanning electron microscopic (SEM) investigation of the implant surfaces of the different prostheses was carried out on new samples received from the manufacturers. During a prospective study on eight patients, capsule samples corresponding to the four above-mentioned prostheses were taken to determine whether a secondary intervention was necessary for correction of asymmetry or malpositioning. These samples were analyzed by SEM to investigate whether there could be a correlation between prosthesis texturing and the aspect of the corresponding capsules. Significant ultrastructural differences were found between the various prostheses examined: the results showed that only the CUI and Biocell prostheses presented a mirror image of the capsule texturing, with a correspondence between the depressions on the prosthesis and the contacts on the capsule. This finding seems to be linked to the existence of a critical size for the pores that constitute the implant surface. This observation led to the hypothesis of an adhesive "velcro" effect between the prosthesis and its capsule. Although the latter may not be directly linked to the prevention of capsular contracture it can, however, have a major effect on implant stabilization in cases of primary breast reconstruction and in possible secondary adjustments of asymmetry and malpositioning.

  14. The Poly Implant Prothèse breast prostheses scandal: Embodied risk and social suffering.

    Science.gov (United States)

    Greco, Cinzia

    2015-12-01

    This article examines the 2010 scandal surrounding the use and subsequent recall of adulterated Poly Implant Prothèse (PIP) silicone breast prostheses in France. It uses a mixed method approach that includes 12 interviews with French PIP prosthesis recipients, analyses of medical literature, policy documents of French and EU regulatory agencies, and an online forum for PIP recipients. These data are used to explain how the definition of "acceptable risk" in the silicone implants controversy of the 1990s in the US influenced the PIP scandal later on in France. Additionally, PIP recipients had an embodied experience of risk that clashed with the definition of risk used by authorities and some surgeons. The coverage of re-implantation was also defined at different policy levels, leading to variation in patients' suffering. The combination of fraud and lack of recognition from part of the medical system constitutes an example of social suffering for the patients involved. The PIP scandal is a useful case for analyzing the interconnection of embodied experience and professional and public policy definitions of medical risk through the concepts of moral economy and biological citizenship. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. Study to the presence of antipolymer antibodies in a group of Dutch women with a silicone breast implant. Part II

    NARCIS (Netherlands)

    Jong WH de; Kallewaard M; Verhoef CM; Bijlsma JWJ; Schouten JSAG; Loveren H van; Afdeling Reumatologie en; LPI; LGM

    2002-01-01

    The presence of antipolymer antibodies (APA) was reported in women with severe symptoms and a silicone breast implant (SBI). The aim of the present study was to determine whether there exists a population of symptomatic SBI recipients with a high prevalence of APA in the Netherlands. Participants

  16. Comparison between magnetic resonance findings and conventional techniques (ultrasonography and mammography) in breast disease

    International Nuclear Information System (INIS)

    Martin, J.L.; Garofono, J.M.; Berquet, A.; Fernandez, F.J.; Fuentes, P.; Alvarez de Cienfuegos, E.

    1996-01-01

    Although mammography is indisputably the best diagnostic method for detecting breast abnormalities, there are other techniques, such as ultrasonography and magnetic resonance, which are increasingly widely employed as additional indispensable aids. The present work compares mammography, ultrasound and magnetic resonance images of normal breast and of the major pathologies that can be observed in breast, including sclerosing adenosis, giant fibroadenoma, multifocal carcinoma, fibrocystic breast disease, infiltrating duct carcinoma, colloid carcinoma, radical scar, abscess and breast prosthesis. (Author) 10 refs

  17. Magnetic resonance imaging of breast implants.

    Science.gov (United States)

    Shah, Mala; Tanna, Neil; Margolies, Laurie

    2014-12-01

    Silicone breast implants have significantly evolved since their introduction half a century ago, yet implant rupture remains a common and expected complication, especially in patients with earlier-generation implants. Magnetic resonance imaging is the primary modality for assessing the integrity of silicone implants and has excellent sensitivity and specificity, and the Food and Drug Administration currently recommends periodic magnetic resonance imaging screening for silent silicone breast implant rupture. Familiarity with the types of silicone implants and potential complications is essential for the radiologist. Signs of intracapsular rupture include the noose, droplet, subcapsular line, and linguine signs. Signs of extracapsular rupture include herniation of silicone with a capsular defect and extruded silicone material. Specific sequences including water and silicone suppression are essential for distinguishing rupture from other pathologies and artifacts. Magnetic resonance imaging provides valuable information about the integrity of silicone implants and associated complications.

  18. Nasal prosthesis rehabilitation: a case report

    DEFF Research Database (Denmark)

    Jain, Sumeet; Maru, Kavita; Shukla, Jyotsana

    2011-01-01

    Facial defects resulting from neoplasm, congenital malformation or trauma can be restored with facial prosthesis using different materials and retention methods to achieve life-like look and function. A nasal prosthesis can re-establish esthetic form and anatomic contours for mid-facial defects...... the non-surgical rehabilitation, with polymethyl meth-acrylate resin, nasal prosthesis for a patient who received partial rhinectomy as a result of squamous cell carcinoma of the nose. The prosthesis was made to restore the esthetic appearance of the patient with a mechanical retained design using...

  19. Five-Year Safety Data for More than 55,000 Subjects following Breast Implantation: Comparison of Rare Adverse Event Rates with Silicone Implants versus National Norms and Saline Implants.

    Science.gov (United States)

    Singh, Navin; Picha, George J; Hardas, Bhushan; Schumacher, Andrew; Murphy, Diane K

    2017-10-01

    The U.S. Food and Drug Administration has required postapproval studies of silicone breast implants to evaluate the incidence of rare adverse events over 10 years after implantation. The Breast Implant Follow-Up Study is a large 10-year study (>1000 U.S. sites) evaluating long-term safety following primary augmentation, revision-augmentation, primary reconstruction, or revision-reconstruction with Natrelle round silicone breast implants compared with national norms and outcomes with saline implants. Targeted adverse events in subjects followed for 5 to 8 years included connective tissue diseases, neurologic diseases, cancer, and suicide. The safety population comprised 55,279 women (primary augmentation, n = 42,873; revision-augmentation, n = 6837; primary reconstruction, n = 4828; and revision-reconstruction, n = 741). No targeted adverse events occurred at significantly greater rates in silicone implant groups versus national norms across all indications. The standardized incidence rate (observed/national norm) for all indications combined was 1.4 for cervical/vulvar cancer, 0.8 for brain cancer, 0.3 for multiple sclerosis, and 0.1 for lupus/lupus-like syndrome. Silicone implants did not significantly increase the risk for any targeted adverse events compared with saline implants. The risk of death was similar with silicone versus saline implants across all indications. The suicide rate (10.6 events per 100,000 person-years) was not significantly higher than the national norm. No implant-related deaths occurred. Results from 5 to 8 years of follow-up for a large number of subjects confirmed the safety of Natrelle round silicone implants, with no increased risk of systemic disease or suicide versus national norms or saline implants. Therapeutic, II.

  20. Cyclodextrin-Modified Porous Silicon Nanoparticles for Efficient Sustained Drug Delivery and Proliferation Inhibition of Breast Cancer Cells.

    Science.gov (United States)

    Correia, Alexandra; Shahbazi, Mohammad-Ali; Mäkilä, Ermei; Almeida, Sérgio; Salonen, Jarno; Hirvonen, Jouni; Santos, Hélder A

    2015-10-21

    Over the past decade, the potential of polymeric structures has been investigated to overcome many limitations related to nanosized drug carriers by modulating their toxicity, cellular interactions, stability, and drug-release kinetics. In this study, we have developed a successful nanocomposite consisting of undecylenic acid modified thermally hydrocarbonized porous silicon nanoparticles (UnTHCPSi NPs) loaded with an anticancer drug, sorafenib, and surface-conjugated with heptakis(6-amino-6-deoxy)-β-cyclodextrin (HABCD) to show the impact of the surface polymeric functionalization on the physical and biological properties of the drug-loaded nanoparticles. Cytocompatibility studies showed that the UnTHCPSi-HABCD NPs were not toxic to breast cancer cells. HABCD also enhanced the suspensibility and both the colloidal and plasma stabilities of the UnTHCPSi NPs. UnTHCPSi-HABCD NPs showed a significantly increased interaction with breast cancer cells compared to bare NPs and also sustained the drug release. Furthermore, the sorafenib-loaded UnTHCPSi-HABCD NPs efficiently inhibited cell proliferation of the breast cancer cells.

  1. Comparison of Range of Motion After Total Knee Prosthesis According to Different Type of Prosthesis

    Directory of Open Access Journals (Sweden)

    Firat Seyfettinoglu

    2016-07-01

    Full Text Available Aim: The aim of this study is to determine the effectiveness and range of motion of different type of knee prosthesis. Material and Method: This study includes 180 of 225 patients (139 F, 41 M, average age: 65, range of age: 51-82 between April 2005 and September 2007 with the diagnosis of gonarthrosis. All patients underwent to primary total knee arthroplasty. Primary osteoartrhritis is the reason of gonarthrosis. The patients with secondary osteoartrhritis were excluded from the study. All the patients were operated by the same surgical team and rehabilitated after surgery. Patella didnt change any patient. PCL was protected in some of the patients and cut some of patients. Totally seven type prosthesis in 16 subgroup were applied to the patients. All measurement were done by the same surgeon. Average follow up period was 31 months (24-49 months. Results: Patients without subgrouping were tested according to the range of motion before and after surgery to the type of the prosthesis trademark. Range of motion was decreased with the usage of Rotaglide and LCS® type of prosthesis. Range of motion didnt change with the usage of Maxim and Kinemax type. The range of motion increased in the other trademark of prosthesis. Flexion angle was increased statistically significant with nexgen® and scorpio® prosthesis (p

  2. Implant-Retained Auricular Prosthesis: A Case Report

    OpenAIRE

    Ozturk, A. Nilgun; Usumez, Aslihan; Tosun, Zekeriya

    2010-01-01

    Extraoral implant retained prosthesis have been proven to be a predictable treatment option for maxillofacial rehabilitation. This case report describes the clinical and laboratory procedures for fabricating an auricular prosthesis. In this case report, an auricular prosthesis was fabricated for a patient who lost the left and right external ear in an electrical burn. Extraoral implants and bar-and-clip retention for the proper connection of the auricular prosthesis to implant were used. This...

  3. Permanent Quadriplegia Following Replacement of Voice Prosthesis.

    Science.gov (United States)

    Ozturk, Kayhan; Erdur, Omer; Kibar, Ertugrul

    2016-11-01

    The authors presented a patient with quadriplegia caused by cervical spine abscess following voice prosthesis replacement. The authors present the first reported permanent quadriplegia patient caused by voice prosthesis replacement. The authors wanted to emphasize that life-threatening complications may be faced during the replacement of voice prosthesis. Care should be taken during the replacement of voice prosthesis and if some problems have been faced during the procedure patients must be followed closely.

  4. Laser-assisted fixation of a nitinol stapes prosthesis.

    Science.gov (United States)

    Schrötzlmair, Florian; Suchan, Fabian; Pongratz, Thomas; Krause, Eike; Müller, Joachim; Sroka, Ronald

    2018-02-01

    Otosclerosis is an inner ear bone disease characterized by fixation of the stapes and consequently progressive hearing loss. One treatment option is the surgical replacement of the stapes by a prosthesis. When so called "smart materials" like nitinol are used, prosthesis fixation can be performed using a laser without manual crimping on the incus. However, specific laser-prosthesis interactions have not been described yet. The aim of the present study was to elucidate the thermo-mechanical properties of the NiTiBOND® prosthesis as a basis for handling instructions for laser-assisted prosthesis fixation. Closure of the NiTiBOND® prosthesis was induced ex vivo by either a diode laser emitting at λ = 940 nm or a CO 2 laser (λ = 10,600 nm). Total energy for closure was determined. Suitable laser parameters (pulse duration, power per pulse, distance between tip of the laser fiber and prosthesis) were assessed. Specific laser-prosthesis interactions were recorded. Especially the diode laser was found to be an appropriate energy source. A total energy deposit of 60 mJ by pulses in near contact application was found to be sufficient for prosthesis closure ex vivo. Energy should be transmitted through a laser fiber equipollent to the prosthesis band diameter. Specific deformation characteristics due to the zonal prosthesis composition have to be taken into account. NiTiBOND® stapes prosthesis can be closed by very little energy when appropriate energy sources like diode lasers are used, suggesting a relatively safe application in vivo. Lasers Surg. Med. 50:153-157, 2018. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  5. Patients with hip prosthesis: radiotherapy treatment planning considerations

    International Nuclear Information System (INIS)

    Ganesh, K.M.; Supe, Sanjay S.

    2000-01-01

    The number of patients with hip prosthesis undergoing radiotherapy for pelvic cancer worldwide is increasing. This might be of importance depending on the materials in the prosthesis and whether any of the treatment fields are involved in the prosthesis. Radiotherapy planning involving the pelvic region of patients having total hip prosthesis has been found to be difficult due to the effect of the prosthesis on the dose distribution. This review is intended to project dosimetric considerations and possible solutions to this uncommon problem

  6. Electrochemical approach for monitoring the effect of anti tubulin drugs on breast cancer cells based on silicon nanograss electrodes

    International Nuclear Information System (INIS)

    Zanganeh, Somayeh; Khosravi, Safoora; Namdar, Naser; Amiri, Morteza Hassanpour; Gharooni, Milad; Abdolahad, Mohammad

    2016-01-01

    One of the most interested molecular research in the field of cancer detection is the mechanism of drug effect on cancer cells. Translating molecular evidence into electrochemical profiles would open new opportunities in cancer research. In this manner, applying nanostructures with anomalous physical and chemical properties as well as biocompatibility would be a suitable choice for the cell based electrochemical sensing. Silicon based nanostructure are the most interested nanomaterials used in electrochemical biosensors because of their compatibility with electronic fabrication process and well engineering in size and electrical properties. Here we apply silicon nanograss (SiNG) probing electrodes produced by reactive ion etching (RIE) on silicon wafer to electrochemically diagnose the effect of anticancer drugs on breast tumor cells. Paclitaxel (PTX) and mebendazole (MBZ) drugs have been used as polymerizing and depolymerizing agents of microtubules. PTX would perturb the anodic/cathodic responses of the cell-covered biosensor by binding phosphate groups to deformed proteins due to extracellular signal-regulated kinase (ERK"1"/"2) pathway. MBZ induces accumulation of Cytochrome C in cytoplasm. Reduction of the mentioned agents in cytosol would change the ionic state of the cells monitored by silicon nanograss working electrodes (SiNGWEs). By extending the contacts with cancer cells, SiNGWEs can detect minor signal transduction and bio recognition events, resulting in precise biosensing. Effects of MBZ and PTX drugs, (with the concentrations of 2 nM and 0.1 nM, respectively) on electrochemical activity of MCF-7 cells are successfully recorded which are corroborated by confocal and flow cytometry assays. - Highlights: • Electrochemical effect of MBZ and PTX (anti tubulin drugs) on breast cancer cells was detected. • Detection was carried by silicon nanograss electrodes(SiNGEs). • Signaling pathways activated in the cells by drug treatment, change the anodic

  7. Electrochemical approach for monitoring the effect of anti tubulin drugs on breast cancer cells based on silicon nanograss electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Zanganeh, Somayeh; Khosravi, Safoora; Namdar, Naser; Amiri, Morteza Hassanpour; Gharooni, Milad [Nano Electronic Center of Excellence, Nano Bio Electronic Devices Lab, School of Electrical and Computer Eng, University of Tehran, P.O. Box 14395/515, Tehran (Iran, Islamic Republic of); Nano Electronic Center of Excellence, Thin Film and Nanoelectronic Lab, School of Electrical and Computer Eng, University of Tehran, P.O. Box 14395/515, Tehran (Iran, Islamic Republic of); Abdolahad, Mohammad, E-mail: m.abdolahad@ut.ac.ir [Nano Electronic Center of Excellence, Nano Bio Electronic Devices Lab, School of Electrical and Computer Eng, University of Tehran, P.O. Box 14395/515, Tehran (Iran, Islamic Republic of); Nano Electronic Center of Excellence, Thin Film and Nanoelectronic Lab, School of Electrical and Computer Eng, University of Tehran, P.O. Box 14395/515, Tehran (Iran, Islamic Republic of)

    2016-09-28

    One of the most interested molecular research in the field of cancer detection is the mechanism of drug effect on cancer cells. Translating molecular evidence into electrochemical profiles would open new opportunities in cancer research. In this manner, applying nanostructures with anomalous physical and chemical properties as well as biocompatibility would be a suitable choice for the cell based electrochemical sensing. Silicon based nanostructure are the most interested nanomaterials used in electrochemical biosensors because of their compatibility with electronic fabrication process and well engineering in size and electrical properties. Here we apply silicon nanograss (SiNG) probing electrodes produced by reactive ion etching (RIE) on silicon wafer to electrochemically diagnose the effect of anticancer drugs on breast tumor cells. Paclitaxel (PTX) and mebendazole (MBZ) drugs have been used as polymerizing and depolymerizing agents of microtubules. PTX would perturb the anodic/cathodic responses of the cell-covered biosensor by binding phosphate groups to deformed proteins due to extracellular signal-regulated kinase (ERK{sup 1/2}) pathway. MBZ induces accumulation of Cytochrome C in cytoplasm. Reduction of the mentioned agents in cytosol would change the ionic state of the cells monitored by silicon nanograss working electrodes (SiNGWEs). By extending the contacts with cancer cells, SiNGWEs can detect minor signal transduction and bio recognition events, resulting in precise biosensing. Effects of MBZ and PTX drugs, (with the concentrations of 2 nM and 0.1 nM, respectively) on electrochemical activity of MCF-7 cells are successfully recorded which are corroborated by confocal and flow cytometry assays. - Highlights: • Electrochemical effect of MBZ and PTX (anti tubulin drugs) on breast cancer cells was detected. • Detection was carried by silicon nanograss electrodes(SiNGEs). • Signaling pathways activated in the cells by drug treatment, change the

  8. Magnetic Resonance Imaging Screening Results Compared with Explantation Results in Poly Implant Prothese Silicone Breast Implants, Recalled from the European Market in 2010

    NARCIS (Netherlands)

    Maijers, M.C.; Niessen, F.B.; Veldhuizen, J.F.H.; Ritt, M.J.P.F.; Manoliu, R.A.

    2014-01-01

    BACKGROUND: In a prospective cohort study, the authors followed 112 women whose Poly Implant Prothèse silicone breast implants were recalled. Magnetic resonance imaging results and clinical consequences were previously published. The authors compared magnetic resonance imaging screening with

  9. Anaplastic large cell lymphoma of the breast arising around mammary implant capsule: an Italian report.

    Science.gov (United States)

    Farace, Francesco; Bulla, Antonio; Marongiu, Francesco; Campus, Gian Vittorio; Tanda, Francesco; Lissia, Amelia; Cossu, Antonio; Fozza, Claudio; Rubino, Corrado

    2013-06-01

    Anaplastic large cell lymphoma (ALCL) of the breast is a very rare nonepithelial neoplasm. In the literature, this tumor has sometimes been described in proximity of breast implants (60 implant-related ALCL reported). In 2010, a patient who had undergone a right mastectomy and tissue expander/implant reconstruction for a "ductal" carcinoma 10 years before was referred to our unit for evaluation. On examination, an enlarged reconstructed right breast was found. The reconstructed breast did not show tenderness or signs of infection, ulceration, or breakdown. Mammograms and ultrasound scan did not suggest the presence of recurrent cancer, infection, deflation of the implant, or severe capsule contracture. The patient underwent mammary implant replacement. About 3 weeks after surgery, the patient came back to our unit for a new mild enlargement of the operated breast and the implant was removed. Three months later, the patient returned with a skin lesion in the right parasternal region. A radical excisional biopsy was performed under local anesthesia and the diagnosis of ALK-1-negative ALCL was finally made. The clinical and histological diagnosis of this disease is difficult as it can often be mistaken for a simple seroma (breast enlargement), an infection, or an unspecific reaction to silicone (redness and/or tension of the skin, itching, and fever). We strongly suggest considering ALCL in any patient with a spontaneous breast seroma lasting more than 6 months after mammary prosthesis implantation. The suspicion of ALCL must be suggested to the pathologist immediately. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  10. Magnetic resonance imaging of the breast: current indications

    International Nuclear Information System (INIS)

    Lalonde, L.; David, J.; Trop, I.

    2005-01-01

    Breast magnetic resonance imaging (MRI) plays an increasing role in the management of selecting breast cancer patients. MRI is recognized as the most sensitive modality for the detection of invasive breast cancer. Several valuable clinical applications of MRI have emerged for breast cancer detection and diagnosis from clinical investigations. Breast MRI is helpful for women diagnosed with breast cancer who contemplate breast conserving surgery; it provides valuable information on the extent of the disease. MRI can also help assess for residual invasive cancer in patients who have undergone lumpectomy with positive margins at pathology. It is very reliable in differentiating scar tissue from recurrence at the lumpectomy site. MRI is also reliable in finding a breast cancer in women with axillary nodal metastases and unknown primary tumour. MRI can help to monitor the response to chemotherapy. Breast MRI could be a better screening tool than mammography in women with very high risks of developing breast cancer, such as breast cancer gene carriers and patients treated with chest radiation. Other potential uses of MRI include evaluation of the integrity of silicone breast implants and evaluation of the parenchyma in women with silicone gel implants or free injection of silicone gel. However, like any other technique, breast MRI has some drawbacks, including low-to-moderate specificity, high costs, and variability in technique and interpretation. Radiologists must have a clear understanding of valid indications and selection criteria to use this technique appropriately. (author)

  11. Air-flow resistances of silicone rubber voice prostheses after formation of bacterial and fungal biofilms

    NARCIS (Netherlands)

    Elving, GJ; van der Mei, HC; Busscher, HJ; van Weissenbruch, R; Albers, FWJ

    Laryngectomized patients use silicone rubber voice prostheses to rehabilitate their voice. However, biofilm formation limits the lifetime of voice prostheses by causing leakage or an increased air-flow resistance and the prosthesis has to be replaced. To determine which bacterial or yeast strains,

  12. Implant salvage in breast reconstruction with severe peri-prosthetic infection.

    Science.gov (United States)

    Meybodi, Farid; Sedaghat, Negin; French, James; Keighley, Caitlin; Mitchell, David; Elder, Elisabeth

    2017-12-01

    Although treatment of mild peri-prosthetic infection in implant-based breast reconstruction results in high rates of resolution, successful management of severe peri-prosthetic infection remains a significant challenge. In this case series, a protocol utilizing a novel dressing - negative pressure wound therapy with instillation (NPWTi) - for the management of severe peri-prosthetic infection in breast reconstruction patients is described. This is an operative technique involving: (i) explantation of the breast prosthesis and application of the NPWTi dressing to the implant pocket; (ii) change of the NPWTi dressing; (iii) intraoperative fluid/tissue cultures; and (iv) reimplantation of the breast prosthesis when cultures yield no growth. This protocol was utilized in six cases of severe peri-prosthetic infection in five patients with immediate breast reconstruction for breast cancer or risk-reducing surgery. Cultures of fluid/tissue grew typical and/or unusual organisms. Only one case did not yield an organism. The hospital length of stay upon completion of the protocol ranged from 7-16 days (mean, 12 days). Successful implant salvage was achieved in five of six cases. The protocol was aborted in one case to allow for completion of adjuvant chemotherapy. Early findings from this case series suggest that in cases of severe peri-prosthetic infection this novel operative protocol may result in successful implant salvage for breast reconstruction patients. Further studies are needed to more fully elaborate the role of NPWTi to achieve implant salvage in challenging cases of peri-prosthetic infection. © 2015 Royal Australasian College of Surgeons.

  13. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    Science.gov (United States)

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  14. 21 CFR 872.3960 - Mandibular condyle prosthesis.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3960 Mandibular condyle prosthesis. (a) Identification. A mandibular condyle prosthesis is a device that is intended to be implanted in the human jaw to... requirement for premarket approval for any mandibular condyle prosthesis intended to be implanted in the human...

  15. Experimental testing on free vibration behaviour for silicone rubbers proposed within lumbar disc prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Rotaru, Iuliana, E-mail: rotaruiuliana2000@gmail.com [“Gheorghe Asachi” Technical University of Iasi, Faculty of Mechanical Engineering, Department of Mechanical Engineering, Mechatronics and Robotics, 61-63 Bd. Dimitrie Mangeron, 700050 Iasi (Romania); “Gr. T. Popa” University of Medicine and Pharmacy of Iasi, Faculty of Medical Bioengineering, Department of Biomedical Sciences, 9-13 M. Kogalniceanu Street, 700454 Iasi (Romania); Bujoreanu, Carmen [“Gheorghe Asachi” Technical University of Iasi, Faculty of Mechanical Engineering, Department of Mechanical Engineering, Mechatronics and Robotics, 61-63 Bd. Dimitrie Mangeron, 700050 Iasi (Romania); Bele, Adrian; Cazacu, Maria [“Petru Poni” Institute of Macromolecular Chemistry, Aleea Gr. Ghica Voda 41 A, 700487 Iasi (Romania); Olaru, Dumitru [“Gheorghe Asachi” Technical University of Iasi, Faculty of Mechanical Engineering, Department of Mechanical Engineering, Mechatronics and Robotics, 61-63 Bd. Dimitrie Mangeron, 700050 Iasi (Romania)

    2014-09-01

    This research was focused on the damping capacity study of two types of silicone rubbers proposed as layers within total lumbar disc prostheses of ball-and-socket model. In order to investigate the damping capacity, the two silicone rubber types mainly differing by the molecular mass of polymeric matrix and the filler content, as was emphasized by scanning electron microscopy and differential scanning calorimetry, were subjected to free vibration testing. Using an adapted experimental installation, three kinds of damping testing were realised: tests without samples and tests with three samples of each type of silicone rubber (69 ShA and 99 ShA). The free vibration tests were performed at a frequency of about 6 Hz using a weight of 11.8 kg. The relative damping coefficient was determined by measuring of two successive amplitudes on the vibrogram and calculating of the logarithmic decrement. The test results with silicone rubber samples showed a relative damping coefficient of 0.058 and respectively 0.077, whilst test results without samples showed a relative damping coefficient of 0.042. These silicone rubbers were found to have acceptable damping properties to be used as layers placed inside the prosthetic components. - Highlights: • Two types of silicone rubber were proposed within the total lumbar disc prostheses. • The filler content of elastomers was highlighted by microscopy investigation. • Damping capacity of the two elastomers was evaluated using free vibration analysis. • The logarithmic decrement and the relative damping coefficient were determined. • The silicone rubbers prepared in our work showed acceptable damping properties.

  16. Experimental testing on free vibration behaviour for silicone rubbers proposed within lumbar disc prosthesis

    International Nuclear Information System (INIS)

    Rotaru, Iuliana; Bujoreanu, Carmen; Bele, Adrian; Cazacu, Maria; Olaru, Dumitru

    2014-01-01

    This research was focused on the damping capacity study of two types of silicone rubbers proposed as layers within total lumbar disc prostheses of ball-and-socket model. In order to investigate the damping capacity, the two silicone rubber types mainly differing by the molecular mass of polymeric matrix and the filler content, as was emphasized by scanning electron microscopy and differential scanning calorimetry, were subjected to free vibration testing. Using an adapted experimental installation, three kinds of damping testing were realised: tests without samples and tests with three samples of each type of silicone rubber (69 ShA and 99 ShA). The free vibration tests were performed at a frequency of about 6 Hz using a weight of 11.8 kg. The relative damping coefficient was determined by measuring of two successive amplitudes on the vibrogram and calculating of the logarithmic decrement. The test results with silicone rubber samples showed a relative damping coefficient of 0.058 and respectively 0.077, whilst test results without samples showed a relative damping coefficient of 0.042. These silicone rubbers were found to have acceptable damping properties to be used as layers placed inside the prosthetic components. - Highlights: • Two types of silicone rubber were proposed within the total lumbar disc prostheses. • The filler content of elastomers was highlighted by microscopy investigation. • Damping capacity of the two elastomers was evaluated using free vibration analysis. • The logarithmic decrement and the relative damping coefficient were determined. • The silicone rubbers prepared in our work showed acceptable damping properties

  17. Rehabilitation of Nose following Chemical Burn Using CAD/CAM Made Substructure for Implant Retained Nasal Prosthesis: A Clinical Report

    Directory of Open Access Journals (Sweden)

    Saurabh Chaturvedi

    2017-01-01

    Full Text Available Insufficient knowledge of medical chemicals and their improper use have destructive effects. Accidental exposure to chemicals on facial tissue may result in large facial defect. For ages the tradition of piercing nose is common but improper use of unknown chemical for piercing has deleterious effect. Mostly rhinectomy defects are acquired caused by trauma or malignant diseases. Prosthetic rehabilitation is the preferred treatment of choice for any large rhinectomy defects as medical and surgical interventions are ineffective in developing esthetics. Main concern with the prosthesis for such defects is retention. This article describes rehabilitation of a patient with large size nasal defect created by chemical burn in childhood during piercing. Implant retained customized silicone nasal prosthesis was fabricated using simple O-ring attachments and innovative modified polyamide acrylic resin substructure acting as skeleton.

  18. Duocentric® reversed shoulder prosthesis and Personal Fit® templates: innovative strategies to optimize prosthesis positioning and prevent scapular notching.

    Science.gov (United States)

    Trouilloud, P; Gonzalvez, M; Martz, P; Charles, H; Handelberg, F; Nyffeler, R W; Baulot, E

    2014-05-01

    We describe our experience with a new system of patient-specific template called Personal Fit(®), which is unique in shoulder surgery and used in combination with Duocentric(®) prosthesis. The reverse prosthesis's concept is the invention of Paul Grammont, developed with Grammont's team of Dijon University as from 1981, which led to the first reversed total shoulder prosthesis called Trumpet in 1985. The Duocentric(®) prosthesis developed in 2001 is the third-generation prosthesis, coming from the Trumpet and the second-generation prosthesis Delta(®) (DePuy). This prosthesis provides a novel solution to the notching problem with an inferior overhang integrated onto the glenoid baseplate. Personal Fit(®) system is based on reconstructing the shoulder joint bones in three dimensions using CT scan data, placing a landmark on the scapula and locating points on the glenoid and humerus. That will be used as a reference for the patient-specific templates. We study the glenoid position planned with Personal Fit(®) software relative to native glenoid position in 30 cases. On average, the difference between the planned retroversion (or anteversion in one case) and native retroversion was 8.6°.

  19. Self-reported musculoskeletal symptoms among Danish women with cosmetic breast implants

    DEFF Research Database (Denmark)

    Kjøller, Kim; Hölmich, Lisbet Rosenkrantz; Fryzek, Jon P

    2004-01-01

    No epidemiological evidence of an association between silicone breast implants and connective tissue disease has been found. Based on case reports, it has been hypothesized that silicone breast implants may be associated with a unique rheumatic symptom cluster termed "atypical connective tissue d...

  20. 21 CFR 878.3800 - External aesthetic restoration prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false External aesthetic restoration prosthesis. 878... External aesthetic restoration prosthesis. (a) Identification. An external aesthetic restoration prosthesis... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...

  1. Rehabilitation of a Patient with an Intra Oral Prosthesis and an Extra Oral Orbital Prosthesis Retained with Magnets

    OpenAIRE

    Pattanaik, Seema; Wadkar, Aarti P.

    2011-01-01

    This clinical case report deals with a rehabilitation of a patient with an extensive maxillary and orbital defect using an intra oral prosthesis obturating the maxillary defect and extra oral orbital prosthesis retained with rare-earth magnets for secondary retention; primary retention was derived by snug fit of the prosthesis to underlying and adjacent tissues. The rehabilitation resulted in improved function, esthetics and comfort to the patient thus enabling him to lead a normal life.

  2. Anaplastic large cell lymphoma associated with breast implants

    Directory of Open Access Journals (Sweden)

    Vid Bajuk

    2017-02-01

    Full Text Available An increasing number of women worldwide decide for esthetic correction of breasts with silicone implants and post-cancer breast reconstruction with tissue expanders and silicone breast implants. It is estimated that more than 10 million women around the globe have them. Tere are approximately 200 known cases of patients with anaplastic large cell lymphoma (ALCL linked with silicone breast implants reported in medical literature. ALCL is a rare disease with an annual incidence of 0.1–0.3/100 000 women with breast silicone implants. In the presence of clinical signs, physician should also consider this rare form of ALCL in differential diagnosis. Patients are on average 50 years old. Long afer implantation surgery, the patient may experience breast swelling, pain and/or asymmetry. In diagnostics, ultrasound and cytological examination are required. During ultrasound examination fluid formation (seroma or solid tumor mass can be detected. Treatment is individualized. Due to tumor nature, implant resection and total capsulectomy are usually indicated; also, chemo- and radiotherapy might rarely be required. Five-year survival rate depends on tumor form and correlates well with clinical fndings of seroma or solid mass. In the more frequent form, seroma, fve-year survival rate is 100 %, while in the case of solid tumor mass fve-year survival rate is 75 %. The rarity of this disease makes it difficult to diagnose, but nevertheless, early detection and treatment are important for better recovery.

  3. Experimental testing on free vibration behaviour for silicone rubbers proposed within lumbar disc prosthesis.

    Science.gov (United States)

    Rotaru, Iuliana; Bujoreanu, Carmen; Bele, Adrian; Cazacu, Maria; Olaru, Dumitru

    2014-09-01

    This research was focused on the damping capacity study of two types of silicone rubbers proposed as layers within total lumbar disc prostheses of ball-and-socket model. In order to investigate the damping capacity, the two silicone rubber types mainly differing by the molecular mass of polymeric matrix and the filler content, as was emphasized by scanning electron microscopy and differential scanning calorimetry, were subjected to free vibration testing. Using an adapted experimental installation, three kinds of damping testing were realised: tests without samples and tests with three samples of each type of silicone rubber (69 ShA and 99 ShA). The free vibration tests were performed at a frequency of about 6 Hz using a weight of 11.8 kg. The relative damping coefficient was determined by measuring of two successive amplitudes on the vibrogram and calculating of the logarithmic decrement. The test results with silicone rubber samples showed a relative damping coefficient of 0.058 and respectively 0.077, whilst test results without samples showed a relative damping coefficient of 0.042. These silicone rubbers were found to have acceptable damping properties to be used as layers placed inside the prosthetic components. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Attachment-retained gingival prosthesis for implant-supported fixed dental prosthesis in the maxilla: a clinical report.

    Science.gov (United States)

    Aparecida de Mattias Sartori, Ivete; Uhlendorf, Yuri; Padovan, Luiz Eduardo Marques; Junior, Paulo Domingos Ribeiro; Melo, Ana Cláudia Moreira; Tiossi, Rodrigo

    2014-12-01

    The rehabilitation of edentulous maxillae is a complex procedure due to the involvement of esthetic and functional requirements. A trial maxillary denture can be used to identify the need for adequate upper lip support when replacing removable complete dentures by implant-fixed dental prostheses. This clinical report describes the outcome of the rehabilitation of an edentulous atrophic maxilla with unfavorable maxillomandibular relationship and deficient upper lip support. A trial denture was fabricated and used to diagnose the need for a prosthesis capable of restoring the upper lip support. The reduced upper lip support was also confirmed by a lateral cephalogram. The patient was rehabilitated by an implant-fixed dental prosthesis associated with an attachment-retained gingival prosthesis. The case presented shows that when loss of upper lip support is detected and the patient does not wish to undergo further surgical reconstruction procedure, the retention of a gingival prosthesis using a ball attachment is a satisfactory treatment option. © 2014 by the American College of Prosthodontists.

  5. Prosthesis infections after orthopedic joint replacement

    DEFF Research Database (Denmark)

    Song, Zhijun; Borgwardt, Lotte; Høiby, Niels

    2013-01-01

    Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore...

  6. Life Estimation of Hip Joint Prosthesis

    Science.gov (United States)

    Desai, C.; Hirani, H.; Chawla, A.

    2015-07-01

    Hip joint is one of the largest weight-bearing structures in the human body. In the event of a failure of the natural hip joint, it is replaced with an artificial hip joint, known as hip joint prosthesis. The design of hip joint prosthesis must be such so as to resist fatigue failure of hip joint stem as well as bone cement, and minimize wear caused by sliding present between its head and socket. In the present paper an attempt is made to consider both fatigue and wear effects simultaneously in estimating functional-life of the hip joint prosthesis. The finite element modeling of hip joint prosthesis using HyperMesh™ (version 9) has been reported. The static analysis (load due to the dead weight of the body) and dynamic analysis (load due to walking cycle) have been described. Fatigue life is estimated by using the S-N curve of individual materials. To account for progressive wear of hip joint prosthesis, Archard's wear law, modifications in socket geometry and dynamic analysis have been used in a sequential manner. Using such sequential programming reduction in peak stress has been observed with increase in wear. Finally life is estimated on the basis of socket wear.

  7. 21 CFR 872.3950 - Glenoid fossa prosthesis.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3950 Glenoid fossa prosthesis. (a) Identification. A glenoid fossa prosthesis is a device that is intended to be implanted in the temporomandibular...

  8. Failed total carpometacarpal joint prosthesis of the thumb

    DEFF Research Database (Denmark)

    Hansen, Torben Bæk; Homilius, Morten

    2010-01-01

    Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis. T...... in eight of 10 patients, but the mean Disabilities of the arm, shoulder, and hand (DASH) scores, self-reported pinch-grip-related function, and pain were comparable with our earlier published results with the Elektra carpometacarpal total joint prosthesis.......Total joint prosthesis in carpometacarpal joint arthritis of the thumb often fails. Loosening of the implant is often treated by resection arthroplasty, and we reviewed 10 patients, mean age 54 years (range 47-63) who were treated by resection arthroplasty after a failed total joint prosthesis....... The male:female ratio was 1:4 and the mean duration of observation 32 months (range 6-52). In three patients the revised implant was a MOJE uncemented carpometacarpal joint prosthesis and in seven patients an Elektra uncemented one. At follow-up grip strength was reduced to less than 90% of the other hand...

  9. Stretch due to Penile Prosthesis Reservoir Migration

    Directory of Open Access Journals (Sweden)

    E. Baten

    2016-03-01

    Full Text Available A 43-year old patient presented to the emergency department with stretch, due to impossible deflation of the penile prosthesis, 4 years after successful implant. A CT-scan showed migration of the reservoir to the left rectus abdominis muscle. Refilling of the reservoir was inhibited by muscular compression, causing stretch. Removal and replacement of the reservoir was performed, after which the prosthesis was well-functioning again. Migration of the penile prosthesis reservoir is extremely rare but can cause several complications, such as stretch.

  10. Development and clinical application of a new testicular prosthesis.

    Science.gov (United States)

    Ning, Ye; Cai, Zhikang; Chen, Huixing; Ping, Ping; Li, Peng; Wang, Zhong; Li, Zheng

    2011-11-01

    A new type of testicular prosthesis made of silastic with an elliptical shape to mimic a normal testis was developed by our team and submitted for patenting in China. The prosthesis was produced in different sizes to imitate the normal testis of the patient. To investigate the effects and safety of the testicular prosthesis, 20 patients receiving testicular prosthesis implantation were recruited for this study. Follow-up after 6 months revealed no complications in the patients. All the patients answered that they were satisfied with their body image and the position of the implants, 19 patients were satisfied with the size and 16 patients were satisfied with the weight. These results show that the testicular prosthesis used in this study can meet patient's expectations. Patients undergoing orchiectomy should be offered the option to receive a testicular prosthesis implantation. The dimensions and weight of the available prosthetic implants should be further addressed to improve patient satisfaction.

  11. Femoral Prosthesis Infection by Rhodotorula mucilaginosa▿

    Science.gov (United States)

    Savini, Vincenzo; Sozio, Federica; Catavitello, Chiara; Talia, Marzia; Manna, Assunta; Febbo, Fabio; Balbinot, Andrea; Di Bonaventura, Giovanni; Piccolomini, Raffaele; Parruti, Giustino; D'Antonio, Domenico

    2008-01-01

    This case report is a case history of a femoral prosthesis infection caused by Rhodotorula mucilaginosa in a human immunodeficiency virus patient. Though the pathogenicity of this organism for bone tissue has been previously reported, this is the first reported case of an orthopedic prosthesis infection by this species of the genus Rhodotorula. PMID:18753353

  12. Kinematic analysis of a posterior-stabilized knee prosthesis.

    Science.gov (United States)

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-20

    The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  13. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Directory of Open Access Journals (Sweden)

    Zhi-Xin Zhao

    2015-01-01

    Full Text Available Background: The goal of total knee arthroplasty (TKA is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0-135° flexion. Results: Both the output data trends and the measured values derived from the normal knee′s kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, "rollback" compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis.

  14. Kinematic Analysis of a Posterior-stabilized Knee Prosthesis

    Science.gov (United States)

    Zhao, Zhi-Xin; Wen, Liang; Qu, Tie-Bing; Hou, Li-Li; Xiang, Dong; Bin, Jia

    2015-01-01

    Background: The goal of total knee arthroplasty (TKA) is to restore knee kinematics. Knee prosthesis design plays a very important role in successful restoration. Here, kinematics models of normal and prosthetic knees were created and validated using previously published data. Methods: Computed tomography and magnetic resonance imaging scans of a healthy, anticorrosive female cadaver were used to establish a model of the entire lower limbs, including the femur, tibia, patella, fibula, distal femur cartilage, and medial and lateral menisci, as well as the anterior cruciate, posterior cruciate, medial collateral, and lateral collateral ligaments. The data from the three-dimensional models of the normal knee joint and a posterior-stabilized (PS) knee prosthesis were imported into finite element analysis software to create the final kinematic model of the TKA prosthesis, which was then validated by comparison with a previous study. The displacement of the medial/lateral femur and the internal rotation angle of the tibia were analyzed during 0–135° flexion. Results: Both the output data trends and the measured values derived from the normal knee's kinematics model were very close to the results reported in a previous in vivo study, suggesting that this model can be used for further analyses. The PS knee prosthesis underwent an abnormal forward displacement compared with the normal knee and has insufficient, or insufficiently aggressive, “rollback” compared with the lateral femur of the normal knee. In addition, a certain degree of reverse rotation occurs during flexion of the PS knee prosthesis. Conclusions: There were still several differences between the kinematics of the PS knee prosthesis and a normal knee, suggesting room for improving the design of the PS knee prosthesis. The abnormal kinematics during early flexion shows that the design of the articular surface played a vital role in improving the kinematics of the PS knee prosthesis. PMID:25591565

  15. Body image and prosthesis satisfaction in the lower limb amputee.

    OpenAIRE

    Murray, Craig; Fox, Jezz

    2002-01-01

    Purpose: This study examines the relationship between prosthesis satisfaction and body image in lower limb prosthesis users, and the gendered variations within these relationships. Method: A total of 44 valid responses were obtained to an Internet survey regarding prosthesis satisfaction, body image, and phantom pain. Spearman Rho correlations were calculated for these three domains. Results: Moderate to high negative correlations were observed between Body Image Disturbance and Prosthesis Sa...

  16. Self-contained inflatable penile prosthesis: magnetic resonance appearance

    International Nuclear Information System (INIS)

    Levin, M.F.; Munk, P.L.; Vellet, A.D.; Chin, J.L.

    1994-01-01

    The appearance of an inflatable penile prosthesis, visualized on a short tau inversion recovery sequence, is reported, in a patient who had magnetic resonance imaging for pelvic pain subsequent to radical cystoprostatectomy for bladder carcinoma. With suppression of adjacent fat signal, the prosthesis is well delineated from adjacent structures. The fluid-containing cylinders of the prosthesis are of very bright signal intensity, with the relief valve assembly of low signal intensity. 5 refs., 2 figs

  17. Fabrication of temporary speech bulb prosthesis: A clinical report

    OpenAIRE

    Kasim Mohamed, K.; Anand Kumar, V.; Devi, N.; Padmanaban, T. V.

    2010-01-01

    Maxillofacial prosthesis is an art and science which not only replaces the lost structure sometimes it restores the functions also. Pharyngeal obturator is a prosthesis which closes the palatal and pharyngeal defects and improving the speech and other function. The following case report discusses palatopharyngeal insufficiency, impression procedures, fabrication of prosthesis and improvements in speech.

  18. Femoral hip prosthesis design for Thais using multi-objective shape optimization

    International Nuclear Information System (INIS)

    Virulsri, Chanyaphan; Tangpornprasert, Pairat; Romtrairat, Parineak

    2015-01-01

    Highlights: • A multi-objective shape optimization was proposed to design hip prosthesis for Thais. • The prosthesis design was optimized in terms of safety of both cement and prosthesis. • The objective functions used the Soderberg fatigue strength formulations. • Safety factors of the cement and prosthesis are 1.200 and 1.109 respectively. • The newly designed prosthesis also fits well with chosen small-sized Thai femurs. - Abstract: The long-term success of Total Hip Arthroplasty (THA) depends largely on how well the prosthetic components fit the bones. The majority of cemented femoral hip prosthesis failures are due to aseptic loosening, which is possibly caused by cracking of the cement mantle. The strength of cement components is a function of cement mantles having adequate thickness. Since the size and shape of cemented femoral hip prostheses used in Thailand are based on designs for a Caucasian population, they do not properly conform to most Thai patients’ physical requirements. For these reasons, prostheses designed specifically for Thai patients must consider the longevity and functionality of both cement and prosthesis. The objective of this study was to discover a new design for femoral hip prostheses which is not only optimal and safe in terms of both cement and prosthesis, but also fits the selected Thai femur. This study used a small-sized Thai femoral model as a reference model for a new design. Biocompatible stainless steel 316L (SS316L) and polymethylmethacrylate (PMMA) were selected as raw materials for the prosthesis and bone cement respectively. A multi-objective shape optimization program, which is an interface between optimization C program named NSGA-II and a finite element program named ANSYS, was used to optimize longevity of femoral hip prostheses by varying shape parameters at assigned cross-sections of the selected geometry. Maximum walking loads of sixty-kilograms were applied to a finite element model for stress and

  19. Closed-eye orbital prosthesis: a clinical report.

    Science.gov (United States)

    Hatamleh, Muhanad M; Watson, Jason; Srinivasan, Dilip

    2015-03-01

    One of the most challenging prostheses to fabricate is an acceptable orbital prosthesis. Successful reconstruction of the complex missing tissues, the globe, muscle, skin, and bony elements requires time and high levels of practical skill. A good match to the contralateral nondefect side will help mask the underlying defect and give the patient confidence to return to normal, routine life. The contralateral eye opening will commonly dictate the eye opening of such a prosthesis, but because of the expressive nature of the eye and its high levels of mobility, this can be difficult to achieve. This clinical report presents a patient who had an extended orbital exenteration and right maxillectomy to remove a maxillary squamous cell carcinoma. An alternative approach to constructing an orbital prosthesis was undertaken with the eye closed. Compared to the normal method of fabrication, this process was less complex and quicker, made the prosthesis less "staring," camouflaged the defect, and reduced the detection of the prosthesis because of movements in the remaining eye. The patient engaged in his routine daily life, which reinforced his self-esteem, confidence, and reintegration into the community. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  20. Split-Framework in Mandibular Implant-Supported Prosthesis

    Directory of Open Access Journals (Sweden)

    Danny Omar Mendoza Marin

    2015-01-01

    Full Text Available During oral rehabilitation of an edentulous patient with an implant-supported prosthesis, mandibular flexure must be considered an important biomechanical factor when planning the metal framework design, especially if implants are installed posterior to the interforaminal region. When an edentulous mandible is restored with a fixed implant-supported prosthesis connected by a fixed full-arch framework, mandibular flexure may cause needless stress in the overall restorative system and lead to screw loosening, poor fit of prosthesis, loss of the posterior implant, and patient’s discomfort due to deformation properties of the mandible during functional movements. The use of a split-framework could decrease the stress with a precise and passive fit on the implants and restore a more natural functional condition of the mandible, helping in the longevity of the prosthesis. Therefore, the present clinical report describes the oral rehabilitation of an edentulous patient by a mandibular fixed implant-supported prosthesis with a split-framework to compensate for mandibular flexure. Clinical Significance. The present clinical report shows that the use of a split-framework reduced the risk of loss of the posterior implants or screws loosening with acceptable patient comfort over the period of a year. The split-framework might have compensated for the mandibular flexure during functional activities.

  1. Clinical Outcomes of Penile Prosthesis Implantation Surgery

    Directory of Open Access Journals (Sweden)

    Onur Dede

    2016-06-01

    Full Text Available Objective: We aimed to evaluating the outcomes of in­flatable penile prosthesis implantations and partner sat­isfaction. Methods: Data of 52 patients who underwent penile prosthesis implantation in single center between May 2010 and December 2015 were retrospectively analyzed. Types of prosthesis, complication and satisfaction rates of patients were recorded by EDITS (Erectile Dysfunction Inventory of Treatment Satisfaction questionnaire was used. Results: The mean age was 49.2±14.7 years for patients. The mean follow-up durations for 34.3±12.5 months. The mean hospital stay was 3.84±1.52 days. Evaluating of the couples satisfaction revealed that 44 (84% of the patient were very satisfied. There was not any complication and no patient need to underwent revision surgery. Conclusion: Inflatable penile prosthesis implants, with high levels of treatment success, patient and partner sat­isfaction, are effective and safe options for treatment of organic erectile dysfunction with acceptable complication and revision rates.

  2. Hearing results using the SMart piston prosthesis.

    Science.gov (United States)

    Fayad, Jose N; Semaan, Maroun T; Meier, Josh C; House, John W

    2009-12-01

    SMart, a newly introduced piston prosthesis for stapedotomy, is a nitinol-based, heat-activated, self-crimping prosthesis. We review our hearing results and postoperative complications using this self-crimped piston prosthesis and compare them with those obtained using stainless steel or platinum piston prostheses. Audiometric results using the SMart piston are identical to those obtained using a conventional piston prosthesis. Retrospective chart review. Private neurotologic tertiary referral center. The 416 ears reviewed included 306 with a SMart prosthesis and 110 conventional prostheses. 61% were women. Mean follow-up time was 5.6 (standard deviation [SD], 6.3 mo) and 6.9 months (SD, 7.0 mo) for the 2 groups, respectively. Stapedotomy using the SMart or a conventional (non-SMart) prosthesis. Audiometric hearing results, including pure-tone average (PTA) and air-bone gap (ABG), and prevalence of postoperative complications. Mean postoperative PTA was 32.6 (SD, 16.8) dB for the SMart group and 29.4 (SD, 13.5) dB for the non-SMart group, with ABGs of 7.6 (SD, 8.9) and 6.0 (SD, 5.2) dB, respectively. Mean change (decrease) in ABG was 18.7 (SD, 13.1) dB for the SMart group and 19.9 (SD, 10.3) dB for the non-SMart group. High-frequency bone PTAs showed overclosure of 2.0 (SD, 7.9) dB for the SMart group and 3.6 (SD, 8.6) dB for the non-SMart group. Postoperative vertigo and tinnitus were infrequent. No significant differences in these audiometric outcomes or complication rates were noted between groups. There was no significant difference in rate of gap closure to within 10 dB (78.3 versus 84.2%, SMart and non-SMart, respectively) or 20 dB (94.2 and 98.0%). Compared with conventional stapes prostheses, the nitinol-based SMart is a safe and reliable stapes prosthesis that eliminates manual crimping without significantly altering the audiometric outcome. Complications are rare, but longer follow-up is needed before establishing long-term stability.

  3. 3. Erasmus course on magnetic resonance imaging: breast module. Proceedings

    International Nuclear Information System (INIS)

    Anon.

    1998-01-01

    The third Erasmus Course provides an overwiew of the NMR imaging success of mammary gland cancers. Emphasis is taken on contrast media, postprocessing, technocal problems and pitfalls, as well as the clinical relevance of tumor angiogenesis, histopathology, diagnostic criteria of fast imaging and ultrafast imaging, benign and malignant lesions, prognosis, prosthesis, metastases, multicentricity, chemotherapy and indications of breast cancer

  4. Difficult factors in Management of Impacted Dental Prosthesis in Esophagus

    Directory of Open Access Journals (Sweden)

    Efiaty A. Soepardi

    2005-03-01

    Full Text Available A dental prosthesis which ingested and impacted in esophagus, is an emergency case and life threatening, so require immediate esophagoscopy intervention for removing. The objective of this study is to assess some factors can caused dtfficulties in diagnosing and treating the ingested and impacted dental prosthesis in the esophagus and their complications. This retrospective study analyzed patient’s chart whose underwent esophagoscopy for removing the impacted dental prosthesis in Dr. Cipto Mangunkusumo General Hospital, Jakarta, Indonesia during a period between January 1997 and December 2003. Neck-chest X-ray and esophagoscopy were performed in all patients to identify the existence of the dental prosthesis as a diagnostic and treatment procedure. The length of time for removing the dental prosthesis was recorded and stated as a less difficult esophagoscopy when it takes time less than 60 minutes and as a difficult  esophagoscopy takes 60 minutes or longer. Some risk difficulties factors were statistically analyzed. There were 53 patients of ingested dental prosthesis in esophagus. Only 51 cases were analyzed According to the length of time for removing the dental prosthesis by esophagoscopy, 22 patients were recorded as less difficult cases and 29 patients as difficult cases. Two cases among the cases needed cervicotomy after unsuccessful esophagoscopy removal. The difficulties to diagnose an impacted dental prosthesis in the esophagus caused by unreliable clinical history, unclear signs and symptoms, unable to be detected by X-ray and was not found during esophagoscopy. The difficulties in treating due to mucosal laceration, edema, bleeding, failure of the first extraction and conformity with the size and shape, the wire outside the dental prosthesis and the length of time stayed in the esophagus. (Med J Indones 2005; 14: 33-6Keywords: ingested dental prosthesis, radioluscent foreign body, length of time of esophagoscopy

  5. Impact of aortic prosthesis-patient mismatch on left ventricular mass regression.

    Science.gov (United States)

    Alassal, Mohamed A; Ibrahim, Bedir M; Elsadeck, Nabil

    2014-06-01

    Prostheses used for aortic valve replacement may be small in relation to body size, causing prosthesis-patient mismatch and delaying left ventricular mass regression. This study examined the effect of prosthesis-patient mismatch on regression of left ventricular mass after aortic valve replacement. We prospectively studied 96 patients undergoing aortic valve replacement between 2007 and 2012. Mean and peak gradients and indexed effective orifice area were measured by transthoracic echocardiography at 3 and 6 months postoperatively. Patient-prosthesis mismatch was defined as indexed effective orifice area ≤0.85 cm(2)·m(-2). Moderate prosthesis-patient mismatch was present in 25% of patients. There were no significant differences in demographic and operative data between patients with and without prosthesis-patient mismatch. Left ventricular dimensions, posterior wall thickness, transvalvular gradients, and left ventricular mass decreased significantly after aortic valve replacement in both groups. The interventricular septal diameter and left ventricular mass index regression, and left ventricular ejection fraction were better in patients without prosthesis-patient mismatch. There was a significant positive correlation between the postoperative indexed effective orifice area of each valve prosthesis and the rate of left ventricular mass regression. Prosthesis-patient mismatch leads to higher transprosthetic gradients and impaired left ventricular mass regression. A small-sized valve prosthesis does not necessarily result in prosthesis-patient mismatch, and may be perfectly adequate in patient with small body size. © The Author(s) 2013 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  6. [The endo-exo prosthesis for patients with a problematic amputation stump].

    Science.gov (United States)

    Frölke, Jan Paul M; van de Meent, Henk

    2010-01-01

    Following lower limb amputation, quality of life is highly related to the ability to use a prosthetic limb. The conventional way to attach a prosthetic limb to the body is with a socket. Many patients experience serious discomfort wearing a conventional prosthesis because of pain, instability during walking, pressure sores, bad smell or skin irritation. In addition, sitting is uncomfortable and pelvic and lower back pain due to unstable gait is often seen in these patients. The main disadvantage of the current prosthesis is the attachment of a rigid prosthesis socket to a soft and variable body. The socket must fit tightly for stability during walking but should also be comfortable for sitting. The implantation of an osseointegrated, intramedullary, transcutaneously conducted prosthesis is a new procedure for attaching a limb prosthesis to the human body without the disadvantages of the conventional prosthesis. The intramedullary prosthesis is designed with a rough surface resembling cancellous bone to enable a secure solid integration with the long bone. We treated two patients with this new prosthesis, a 44-year-old man after a transfemoral amputation, and a 32-year-old woman after a lower leg amputation; both amputations were necessary because of trauma. Those two patients are now, more than one year after the operation, showing excellent functional results without infectious complications. We assume that endo-exo prosthesis may be a promising option for selected patients unable to use a conventional prosthesis because of a problematic amputation stump.

  7. Immediate breast reconstruction using autologous skin graft associated with breast implant.

    Science.gov (United States)

    Dutra, A K; Andrade, W P; Carvalho, S M T; Makdissi, F B A; Yoshimatsu, E K; Domingues, M C; Maciel, M S

    2012-02-01

    Immediate breast reconstruction with skin graft is still little mentioned in the literature. Follow-up studies regarding the technique aspects are particularly scarce. The objective was to detail immediate breast reconstruction using autologous skin graft. Patients (n = 49) who underwent mastectomies and autologous immediate breast reconstruction with skin graft associated with a breast implant at A. C. Camargo Hospital (São Paulo, Brazil) between January 2007 and July 2010 were included. Information on clinical data, technique details and clinical outcome were prospectively collected. Following mastectomy, the autologous full-thickness skin graft was obtained through an inframammary fold incision along the contralateral breast in most patients. The skin graft was placed on the surface of the pectoralis major muscle after adjustments to conform to the mastectomy defect. A minimum of 10-month follow-up period was established. Patients' age ranged from 35 to 55 years and all received a silicone gel textured surface implant to obtain the necessary breast mound. The mean surgical time was 45 min, and the mean amount of skin resection was 4.5 cm in the largest diameter. Follow-up ranged from 10 to 35 months (median 23). All patients had silicone-gel textured surface implants to perform the breast mound reconstruction. No complications were observed in 87.8% of reconstructions. Forty-six patients (94%) had no complaints about the donor-site aesthetics. The result was a breast mound with a central ellipse of healed skin graft. Three (6%) poor results were observed. Thirty-six patients (67%) reported the results as good or very good. Our results lead us to conclude that autologous skin graft provided a reliable option in immediate breast reconstruction to skin-sparing mastectomy defects. The technique accomplished a single-stage implant breast reconstruction when there is inadequate skin coverage. Copyright © 2011 British Association of Plastic, Reconstructive and

  8. Clinical predictors of prosthesis-patient mismatch after aortic valve replacement for aortic stenosis

    Directory of Open Access Journals (Sweden)

    Luis M Astudillo

    2012-01-01

    Full Text Available OBJECTIVE: We sought to ascertain predictors of Patient Prosthesis Mismatch, an independent predictor of mortality, in patients with aortic stenosis using bioprosthetic valves. METHOD: We analyzed 2,107 sequential surgeries. Patient Prosthesis Mismatch was calculated using the effective orifice area of the prosthesis divided by the patient's body surface area. We defined nonsignificant, moderate, and severe Patient Prosthesis Mismatch as effective orifice area indexes of .0.85 cm²/m, 0.85-0.66 cm²/m², and <0.65 cm²/m², respectively. RESULTS: A total of 311 bioprosthetic patients were identified. The incidence of nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 41%, 42, and 16%, respectively. Severe Patient Prosthesis Mismatch was significantly more prevalent in females (82%. In severe Patient Prosthesis Mismatch, the perfusion and the crossclamp times were considerably lower when compared with nonsignificant Patient Prosthesis Mismatch and moderate Patient Prosthesis Mismatch. Patients with severe Patient Prosthesis Mismatch had a significantly higher likelihood of spending time in the intensive care unit and a significantly longer length of stay in the hospital. Body surface area was not different in severe Patient Prosthesis Mismatch when compared with nonsignificant Patient Prosthesis Mismatch. In-hospital mortality in patients with nonsignificant, moderate, and severe Patient Prosthesis Mismatch was 2.3%, 6.1%, and 8%, respectively. Minimally invasive surgery was significantly associated with moderate Patient Prosthesis Mismatch in 49% of the patients, but not with severe Patient Prosthesis Mismatch. CONCLUSION: Severe Patient Prosthesis Mismatch is more common in females, but not in those with minimal available body surface area. Though operative times were shorter in these patients, intensive care unit and hospital lengths of stay were longer. Surgeons and cardiologists should be cognizant of these clinical

  9. Linguine sign in musculoskeletal imaging: calf silicone implant rupture.

    Science.gov (United States)

    Duryea, Dennis; Petscavage-Thomas, Jonelle; Frauenhoffer, Elizabeth E; Walker, Eric A

    2015-08-01

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition.

  10. Intermittent, noncyclic dysfunction of a mechanical aortic prosthesis by pannus formation.

    Science.gov (United States)

    Giroux, Sylvie K; Labinaz, Marino X; Grisoli, Dominique; Klug, Andrew P; Veinot, John P; Burwash, Ian G

    2010-01-01

    Mechanical aortic prosthesis dysfunction can result from thrombosis or pannus formation. Pannus formation usually restricts systolic excursion of the occluding disk, resulting in progressive stenosis of the aortic prosthesis. Intermittent dysfunction of a mechanical aortic prosthesis is usually ascribed to thrombus formation. We describe an unusual case of intermittent, noncyclic dysfunction of a mechanical aortic prosthesis due to pannus formation in the absence of systolic restriction of disk excursion that presented with intermittent massive aortic regurgitation, severe ischemia, and shock. Pannus formation should be considered as a potential cause of acute intermittent severe aortic regurgitation in a patient with a mechanical aortic prosthesis.

  11. 21 CFR 888.3760 - Wrist joint carpal scaphoid polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal scaphoid polymer prosthesis. 888.3760 Section 888.3760 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... scaphoid polymer prosthesis. (a) Identification. A wrist joint carpal scaphoid polymer prosthesis is a one...

  12. 21 CFR 888.3750 - Wrist joint carpal lunate polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal lunate polymer prosthesis. 888.3750 Section 888.3750 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... lunate polymer prosthesis. (a) Identification. A wrist joint carpal lunate prosthesis is a one-piece...

  13. 21 CFR 888.3770 - Wrist joint carpal trapezium polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint carpal trapezium polymer prosthesis. 888.3770 Section 888.3770 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... trapezium polymer prosthesis. (a) Identification. A wrist joint carpal trapezium polymer prosthesis is a one...

  14. A modified technique for retention of orbital prosthesis

    Directory of Open Access Journals (Sweden)

    Sameera R Shaikh

    2011-01-01

    Full Text Available An orbital defect (congenital or acquired causes severe facial asymmetry and disfigurement, which results in psychological and social disturbances to the patient. It becomes a challenging task for a maxillofacial prosthodontist to fabricate a prosthesis that replicates the healthy side of the face. Success of the prosthesis depends primarily on satisfactory retention of the same. This clinical report illustrates rehabilitation of a patient with an orbital defect by fabricating a hollow orbital prosthesis, utilizing anatomical undercuts for retention using an acrylic resin template relined by a resilient denture liner.

  15. Communication Protocol for Advanced Prosthesis Components

    OpenAIRE

    Karnå, David

    2007-01-01

    It would be of great value for the prosthesis industry to achieve an open standard for communication in upper limb prostheses. Cooperation between NTNU and the University of New Brunswick has resulted in a functional requirements specification for such a standard, SCIP(Standardised Communication Interface in Prostheses). The special challenges for communication in a prosthesis system are possible noisy environments, high demands for light weight, safety for the user and the fact that devices ...

  16. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report

    Directory of Open Access Journals (Sweden)

    Gayatri Shankaran

    2016-08-01

    Full Text Available Rapid prototyping (RP is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D model created in a computer aided design (CAD system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the cranio-maxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  17. Fabrication of a Cranial Prosthesis Combined with an Ocular Prosthesis Using Rapid Prototyping: A Case Report.

    Science.gov (United States)

    Shankaran, Gayatri; Deogade, Suryakant Chhagan; Dhirawani, Rajesh

    2016-01-01

    Rapid prototyping (RP) is a technique of manufacturing parts by the additive layer manufacturing technology; where, a three-dimensional (3D) model created in a computer aided design (CAD) system is sectioned into 2D profiles, which are further constructed by RP layer by layer. Its use is not limited to industrial or engineering fields and has extended to the medical field for the manufacturing of custom implants and prostheses, the study of anatomy and surgical planning. Nowadays, dentists are more frequently encountered with the individuals affected with craniofacial defects due to trauma. In such cases, the craniomaxillofacial rehabilitation is a real challenge to bring the patients back to society and promote their well-being. The conventional impression technique for facial prosthesis fabrication has the disadvantage of deforming the soft tissue and causing discomfort for the patient. Herein, we describe the fabrication of a cranial prosthesis combined with an ocular prosthesis with RP and stereolithography.

  18. Metabolics of stair ascent with a powered transfemoral prosthesis.

    Science.gov (United States)

    Ledoux, E D; Lawson, B E; Shultz, A H; Bartlett, H L; Goldfarb, M

    2015-01-01

    This paper evaluates the effectiveness of a powered knee and ankle prosthesis for stair ascent through a metabolic assessment comparing energy expenditure of a single transfemoral amputee subject while ascending stairs with the powered prosthesis relative to his passive daily use device, as well as comparing the kinematics and kinetics obtained with the passive prosthesis to healthy biomechanics. The subject wore a portable system that measured pulmonary gaseous exchange rates of oxygen and carbon dioxide while he ascended stairs with each of the prostheses in alternating tests. The results indicated that the amputee's energy expenditure decreased by 32 percent while climbing with the powered prosthesis as compared to his passive one, and the kinematics and kinetics achieved were representative of healthy biomechanics.

  19. Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

    Directory of Open Access Journals (Sweden)

    Sung-Eun Kim

    2014-09-01

    Full Text Available BackgroundIn 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience.MethodsFrom November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction.ResultsThe mean breast resection volume was 240 mL (range, 83-540 mL. The mean size of the breast implants was 217 mL (range, 125-395 mL. Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen.ConclusionsBy using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

  20. Linguine sign in musculoskeletal imaging: calf silicone implant rupture

    International Nuclear Information System (INIS)

    Duryea, Dennis; Petscavage-Thomas, Jonelle; Frauenhoffer, Elizabeth E.; Walker, Eric A.

    2015-01-01

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition. (orig.)

  1. Linguine sign in musculoskeletal imaging: calf silicone implant rupture

    Energy Technology Data Exchange (ETDEWEB)

    Duryea, Dennis; Petscavage-Thomas, Jonelle [Milton S. Hershey Medical Center, Department of Radiology, H066, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Frauenhoffer, Elizabeth E. [Milton S. Hershey Medical Center, Department of Pathology, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Walker, Eric A. [Milton S. Hershey Medical Center, Department of Radiology, H066, 500 University Drive, P.O. Box 850, Hershey, PA (United States); Uniformed Services University of the Health Sciences, Department of Radiology and Nuclear Medicine, Bethesda, MD, 20814 (United States)

    2015-08-15

    Imaging findings of breast silicone implant rupture are well described in the literature. On MRI, the linguine sign indicates intracapsular rupture, while the presence of silicone particles outside the fibrous capsule indicates extracapsular rupture. The linguine sign is described as the thin, wavy hypodense wall of the implant within the hyperintense silicone on T2-weighted images indicative of rupture of the implant within the naturally formed fibrous capsule. Hyperintense T2 signal outside of the fibrous capsule is indicative of an extracapsular rupture with silicone granuloma formation. We present a rare case of a patient with a silicone calf implant rupture and discuss the MRI findings associated with this condition. (orig.)

  2. Penile prosthesis implant: scientific advances and technological innovations over the last four decades.

    Science.gov (United States)

    Chung, Eric

    2017-02-01

    Despite introduction of oral phosphodiesterase type 5 inhibitors and intracavernosal vasoactive agents, penile prosthesis implant remains a relevant and desired option with sales of penile prostheses continue to stay high, as many men became refractory to medical therapy and/or seeking a more effective and permanent therapy. There are two types of penile prosthesis implants: inflatable and non-inflatable types, and the inflatable penile implants can be subdivided into single-, two- and three-piece devices. Non-inflatable penile prosthesis (non-IPP) may be referred to as semi-rigid rod or malleable prosthesis. IPP is considered a superior option to malleable prosthesis as it produces penile rigidity and flaccidity that closely replicates a normal penile erectile function. Since the introduction of IPP by Scott in 1973, surgical landscape for penile prosthesis implantation has changed dramatically. Advances in prosthesis design, device technologies and surgical techniques have made penile prosthesis implant a more natural, durable and reliable device. The following article reviews the scientific advances and technological innovation in modern penile prosthesis implants over the last four decades.

  3. Evaluation of breast implants with breast magnetic resonance: Practical utility in comparison with other methods

    International Nuclear Information System (INIS)

    Melendez, Florencia; Blejman, Oscar; Lamattina Mariano; Villamea, Victoria; Sarquis, Flavio; Torrillo, Fabiana

    2010-01-01

    The purpose of this study was to demonstrate the utility of Breast Magnetic Resonance (BMR) in the evaluation of breast implants comparing Mammography and Breast ultrasound in an ambulatory private institute setting. Method: Between May 2008 and April 2010, 729 BRM were performed in patients between 22 and 77 years of age, 474 were evaluated for implant integrity. The studies were performed in a high field equipment (1.5T) with T1, T2, fat Sat, Silicone only and silicone suppression sequences. Results: Of the 474 patients that were evaluated for implant integrity: 291 patients (61.39%) presented with intact implants, 252 (86.6%) showed concordant findings with mammography and or ultrasound and 39 (13.4%) showed discordant findings. Then, 116 patients (24.47%) presented signs of intracapsular rupture, 82 (70.7%) were concordant with ultrasound findings and 34 (29.3%) had normal ultrasound evaluation. 44 patients (9.28%) presented extracapsular rupture, 40 (90.9%) were concordant with mammography and ultrasound and 4 (9.10%) were discordant. Finally, 23 patients (4.85%) presented residual silicone granulomas, with history of previous implant rupture and explanted surgery, 13 (56.52%) concordant with mammography and ultrasound and 10 (43.48%) were discordant. Conclusion: Non contrast BMR, using multiples planes and sequences is very useful in the evaluation of the internal structure of the implants and extracapsular silicone. It's the most sensible study to demonstrate intra and extracapsular rupture. BMR exceeds mammography and ultrasound in the detection of implant rupture and residual granulomas following explanted surgery.

  4. Automated estimation of hip prosthesis migration: a feasibility study

    Science.gov (United States)

    Vandemeulebroucke, Jef; Deklerck, Rudi; Temmermans, Frederik; Van Gompel, Gert; Buls, Nico; Scheerlinck, Thierry; de Mey, Johan

    2013-09-01

    A common complication associated with hip arthoplasty is prosthesis migration, and for most cemented components a migration greater than 0.85 mm within the first six months after surgery, are an indicator for prosthesis failure. Currently, prosthesis migration is evaluated using X-ray images, which can only reliably estimate migrations larger than 5 mm. We propose an automated method for estimating prosthesis migration more accurately, using CT images and image registration techniques. We report on the results obtained using an experimental set-up, in which a metal prosthesis can be translated and rotated with respect to a cadaver femur, over distances and angles applied using a combination of positioning stages. Images are first preprocessed to reduce artefacts. Bone and prosthesis are extracted using consecutive thresholding and morphological operations. Two registrations are performed, one aligning the bones and the other aligning the prostheses. The migration is estimated as the difference between the found transformations. We use a robust, multi-resolution, stochastic optimization approach, and compare the mean squared intensity differences (MS) to mutual information (MI). 30 high-resolution helical CT scans were acquired for prosthesis translations ranging from 0.05 mm to 4 mm, and rotations ranging from 0.3° to 3° . For the translations, the mean 3D registration error was found to be 0.22 mm for MS, and 0.15 mm for MI. For the rotations, the standard deviation of the estimation error was 0.18° for MS, and 0.08° for MI. The results show that the proposed approach is feasible and that clinically acceptable accuracies can be obtained. Clinical validation studies on patient images will now be undertaken.

  5. Availability of Dental Prosthesis Procedures in Brazilian Primary Health Care

    Directory of Open Access Journals (Sweden)

    Maria Aparecida Gonçalves Melo Cunha

    2018-01-01

    Full Text Available Objectives. To describe dental prosthesis provision in the Brazilian public health service and report the performance of dental prosthesis procedures according to the Brazilian macroregions. Methods. A structured interview was conducted with senior-level health professionals from each of the 18,114 oral health teams (OHT. The dependent variables were performance of removable prostheses and prosthesis procedures, including provision of fixed prostheses by OHT. Descriptive statistics were produced together with performing a cluster analysis using SPSS version 19.0. Results. The manufacture of any type of prosthesis was done by a minority of OHT (43%. The most commonly provided types of dental prosthesis were removable full and partial dentures. Cluster 1 (teams that performed prosthesis procedures the most was composed of a smaller number of teams (n = 5,531, and Cluster 2 (composed of teams that do not perform prosthetics or that perform them in small amounts consisted of 12,583 teams. The geographic distribution of clusters reveals that the largest proportion of Cluster 1 teams is located in the Northeast (33.9% and Southeast (33.6%. Conclusions. A minority of OHT produce dental prostheses. There is an unequal geographical distribution of clusters.

  6. Amputation and prosthesis implantation shape body and peripersonal space representations.

    Science.gov (United States)

    Canzoneri, Elisa; Marzolla, Marilena; Amoresano, Amedeo; Verni, Gennaro; Serino, Andrea

    2013-10-03

    Little is known about whether and how multimodal representations of the body (BRs) and of the space around the body (Peripersonal Space, PPS) adapt to amputation and prosthesis implantation. In order to investigate this issue, we tested BR in a group of upper limb amputees by means of a tactile distance perception task and PPS by means of an audio-tactile interaction task. Subjects performed the tasks with stimulation either on the healthy limb or the stump of the amputated limb, while wearing or not wearing their prosthesis. When patients performed the tasks on the amputated limb, without the prosthesis, the perception of arm length shrank, with a concurrent shift of PPS boundaries towards the stump. Conversely, wearing the prosthesis increased the perceived length of the stump and extended the PPS boundaries so as to include the prosthetic hand, such that the prosthesis partially replaced the missing limb.

  7. Management of long span partially edentulous maxilla with fixed removable denture prosthesis.

    Science.gov (United States)

    Jeyavalan, Mahilan I; Narasimman, M; Venkatakrishnan, C J; Philip, Jacob M

    2012-07-01

    Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  8. Dosimetric influence of hip prosthesis during radiotherapeutic treatment

    International Nuclear Information System (INIS)

    Gschwind, R.; Buffard, E.; Masset, H.; Makovicka, L.; David, C.; David, C.; Buffard, E.

    2008-01-01

    As the population become aged, many patients with hip prosthesis are treated for a pelvic cancer. The recommended ballistic must avoid to pass in the prosthesis, but sometimes it is inevitable. So it is essential to quantify with accuracy the dose modifications linked to the presence of metallic implant. The aim of this study is to analyze by Monte Carlo method these modifications in simple and complex models (anthropomorphic phantom) which take into account the geometry and the composition of the prosthesis and its coatings. Then, this methodology was used to study the behaviour of a treatment planning system in theses extreme conditions. (authors)

  9. Impact of hip prosthesis on dose distribution of pelvic radiotherapy

    International Nuclear Information System (INIS)

    Ren Jiangping; Zhang Songfang; Zhu Qibao; Guo Jianxin; Zha Yuanzi

    2011-01-01

    Objective: To study the scattering effect of Co-Cr-Mo hip prosthesis which was high Z material for patients undergoing pelvic irradiation. Methods: The hip prosthesis was set in water phantom (30 cm x 30 cm x 30 cm), determining points were chosen on the entrance side of both 6 MV and 10 MV beams at the distance of 0.5 cm, 1.0 cm, 2.0 cm to the hip prosthesis, and also on the exit side of both 6 MV and 10 MV beams at the distance of 3.0 cm, 5.0 cm, 7.0 cm to the hip prostheses. Dose behind the hip prosthesis at depths of 5.0 cm and 10.0 cm for 6 MV and 10 MV beams are also measured. Results: The dose deviation on the beams' entrance side is between 0 to 5.0%, the backscatter effect was more obviously with the higher energy beam. The dose deviation on the beams' exit side was between 21.6%-30.8%. With the same field size and depth, dose deviation becomes smaller when the beam energy was higher; while with the same energy and depth, dose deviation becomes smaller when the field size was bigger. Dose profiles behind the head of the hip prosthesis indicate obvious attenuation of the beam. Conclusions: Beam arrangements that avoid the prosthesis should be considered first or we should at least reduce the weight of the beam that pass through the prosthesis. (authors)

  10. Physical Properties of Silicone Gel Breast Implants.

    Science.gov (United States)

    Jewell, Mark L; Bengtson, Bradley P; Smither, Kate; Nuti, Gina; Perry, TracyAnn

    2018-04-28

    Surgical applications using breast implants are individualized operations to fill and shape the breast. Physical properties beyond shape, size, and surface texture are important considerations during implant selection. Compare form stability, gel material properties, and shell thickness of textured shaped, textured round, and smooth round breast implants from 4 manufacturers: Allergan, Mentor, Sientra, and Establishment Labs through bench testing. Using a mandrel height gauge, form stability was measured by retention of dimensions on device movement from a horizontal to vertical supported orientation. Dynamic response of gel material (gel cohesivity, resistance to gel deformation, energy absorption) was measured using a synchronized target laser following application of graded negative pressure. Shell thickness was measured using digital thickness gauge calipers. Form stability, gel material properties, and shell thickness differed across breast implants. Of textured shaped devices, Allergan Natrelle 410 exhibited greater form stability than Mentor MemoryShape and Sientra Shaped implants. Allergan Inspira round implants containing TruForm 3 gel had greater form stability, higher gel cohesivity, greater resistance to gel deformation, and lower energy absorption than those containing TruForm 2 gel and in turn, implants containing TruForm 1 gel. Shell thickness was greater for textured versus smooth devices, and differed across styles. Gel cohesivity, resistance to gel deformation, and energy absorption are directly related to form stability, which in turn determines shape retention. These characteristics provide information to aid surgeons choosing an implant based on surgical application, patient tissue characteristics, and desired outcome.

  11. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint ulnar (hemi-wrist) polymer prosthesis. 888.3810 Section 888.3810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-wrist) polymer prosthesis. (a) Identification. A wrist joint ulnar (hemi-wrist) polymer prosthesis...

  12. 21 CFR 888.3730 - Toe joint phalangeal (hemi-toe) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Toe joint phalangeal (hemi-toe) polymer prosthesis. 888.3730 Section 888.3730 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-toe) polymer prosthesis. (a) Identification. A toe joint phalangeal (hemi-toe) polymer prosthesis...

  13. Penile Corporeal Reconstruction during Difficult Placement of a Penile Prosthesis

    Directory of Open Access Journals (Sweden)

    Viet Q. Tran

    2008-01-01

    Full Text Available For some patients with impotence and concomitant severe tunical/corporeal tissue fibrosis, insertion of a penile prosthesis is the only option to restore erectile function. Closing the tunica over an inflatable penile prosthesis in these patients can be challenging. We review our previous study which included 15 patients with severe corporeal or tunical fibrosis who underwent corporeal reconstruction with autologous rectus fascia to allow placement of an inflatable penile prosthesis. At a mean follow-up of 18 months (range 12 to 64, all patients had a prosthesis that was functioning properly without evidence of separation, herniation, or erosion of the graft. Sexual activity resumed at a mean time of 9 weeks (range 8 to 10. There were no adverse events related to the graft or its harvest. Use of rectus fascia graft for coverage of a tunical defect during a difficult penile prosthesis placement is surgically feasible, safe, and efficacious.

  14. Design and Control of a Pneumatically Actuated Transtibial Prosthesis.

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2015-04-01

    This paper presents the design and control of a pneumatically actuated transtibial prosthesis, which utilizes a pneumatic cylinder-type actuator to power the prosthetic ankle joint to support the user's locomotion. The pneumatic actuator has multiple advantages over the traditional electric motor, such as light weight, low cost, and high power-to-weight ratio. The objective of this work is to develop a compact and lightweight transtibial prosthesis, leveraging the multiple advantages provided by this highly competitive actuator. In this paper, the design details of the prosthesis are described, including the determination of performance specifications, the layout of the actuation mechanism, and the calculation of the torque capacity. Through the authors' design calculation, the prosthesis is able to provide sufficient range of motion and torque capacity to support the locomotion of a 75 kg individual. The controller design is also described, including the underlying biomechanical analysis and the formulation of the finite-state impedance controller. Finally, the human subject testing results are presented, with the data indicating that the prosthesis is able to generate a natural walking gait and sufficient power output for its amputee user.

  15. Prosthesis rejection in acquired major upper-limb amputees: a population-based survey.

    Science.gov (United States)

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-07-01

    To estimate the rates of primary and secondary prosthesis rejection in acquired major upper-limb amputees (ULAs), to describe the most frequently reported reasons for rejection and to estimate the influence of background factors on the risk of rejection. Cross-sectional study analysing population-based questionnaire data (n = 224). Effects were analysed by logistic regression analyses and Cox regression analyses. Primary prosthesis rejection was found in 4.5% whereas 13.4% had discontinued prosthesis use. The main reasons reported for primary non-wear were a perceived lack of need and discrepancies between perceived need and the prostheses available. The main reasons reported for secondary prosthesis rejection were dissatisfaction with prosthetic comfort, function and control. Primary prosthesis rejection was more likely in ULAs amputated at high age and in ULAs with proximal amputations. Secondary prosthesis rejection was more likely in proximal ULAs and in women. Clinicians should be aware of the increased risk of rejection in proximal ULAs, elderly ULAs and in women. Emphasising individual needs will probably facilitate successful prosthetic fitting. Improved prosthesis quality and individualised prosthetic training may increase long-term prosthesis use. Further studies of the effect of prosthetic training and of the reasons for rejection of different prosthetic types are suggested.

  16. Management of long span partially edentulous maxilla with fixed removable denture prosthesis

    Directory of Open Access Journals (Sweden)

    Mahilan I Jeyavalan

    2012-01-01

    Full Text Available Restoration of a long span partially edentulous maxilla with tooth supported prosthesis is challenging because of inherent anatomic limitations and unfavourable biomechanics present after the loss of teeth. A tooth supported fixed-removable prosthesis is a treatment option for restoration of such long span partially edentulous maxillary arches. This prosthesis meets the requirements for esthetics, phonetics, comfort, and hygiene, as well as favourable biomechanical stress distribution to the remaining natural tooth abutments. This article presents a procedure for fabrication of a fixed-removable prosthesis that has cement-retained custom cast bar metal substructure and a ball attachment retained removable superstructure prosthesis.

  17. Osteomyelitis of sternum and rib after breast prosthesis implantation: A rare or underestimated infection?

    Directory of Open Access Journals (Sweden)

    Piseth Seng

    2015-01-01

    Full Text Available Sternum and rib osteomyelitis complicated from breast implant infection is rare. We report a case of early sternum and rib osteomyelitis occurred during breast implant infection managed in an inter-regional referral center for bone/joint infections in the south of France.

  18. 21 CFR 872.3970 - Interarticular disc prosthesis (interpositional implant).

    Science.gov (United States)

    2010-04-01

    ... implant). 872.3970 Section 872.3970 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3970 Interarticular disc prosthesis (interpositional implant). (a) Identification. An interarticular disc prosthesis...

  19. A Retrospective Analysis of Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Woo Yeol Baek

    2014-11-01

    Full Text Available BackgroundRupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants.MethodsWe performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone, duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management.ResultsForty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case, microfat graft (2 case, removal only (14 case, and follow-up loss (17 case.ConclusionsSaline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs.

  20. Reading visual braille with a retinal prosthesis.

    Science.gov (United States)

    Lauritzen, Thomas Z; Harris, Jordan; Mohand-Said, Saddek; Sahel, Jose A; Dorn, Jessy D; McClure, Kelly; Greenberg, Robert J

    2012-01-01

    Retinal prostheses, which restore partial vision to patients blinded by outer retinal degeneration, are currently in clinical trial. The Argus II retinal prosthesis system was recently awarded CE approval for commercial use in Europe. While retinal prosthesis users have achieved remarkable visual improvement to the point of reading letters and short sentences, the reading process is still fairly cumbersome. This study investigates the possibility of using an epiretinal prosthesis to stimulate visual braille as a sensory substitution for reading written letters and words. The Argus II retinal prosthesis system, used in this study, includes a 10 × 6 electrode array implanted epiretinally, a tiny video camera mounted on a pair of glasses, and a wearable computer that processes the video and determines the stimulation current of each electrode in real time. In the braille reading system, individual letters are created by a subset of dots from a 3 by 2 array of six dots. For the visual braille experiment, a grid of six electrodes was chosen out of the 10 × 6 Argus II array. Groups of these electrodes were then directly stimulated (bypassing the camera) to create visual percepts of individual braille letters. Experiments were performed in a single subject. Single letters were stimulated in an alternative forced choice (AFC) paradigm, and short 2-4-letter words were stimulated (one letter at a time) in an open-choice reading paradigm. The subject correctly identified 89% of single letters, 80% of 2-letter, 60% of 3-letter, and 70% of 4-letter words. This work suggests that text can successfully be stimulated and read as visual braille in retinal prosthesis patients.

  1. 99m technetium-MDP bone scintigraphy in evaluation of painful joint prosthesis

    International Nuclear Information System (INIS)

    Milosevic, D.; Jaukovic, M.; Jaukovic, Lj.; Ajdinovic, B.

    2004-01-01

    In addition of clinical evaluation and x-ray radiography, the diagnosis of a loose joint prosthesis is often made by nuclear medicine imaging techniques. Differentiation between loosening and infected prosthesis is important for better treatment of those patients. Aim: The aim of this study was to reevaluate the scintigraphic patterns in patients with painful hip of knee arthroplasty. Material and Method: From 1996. to 2003. forty patients aged 49-78 years were referred for evaluation of possible loosening/infection joint prosthesis: 36 pts with 39 total/ partial hip prosthesis, 1 pt with knee prosthesis and 3 pts with history of previously extracted hip prosthesis due to infection. Whole body acquisition had been performed with a single head gamma camera three hours after the injection of 740 MBq 99m Tc-MDP. Scans were classified as: positive for loosening if abnormal uptake was shown at the tip of the prosthesis; positive for infection if diffuse abnormal uptake was shown around the implant; negative and indeterminate scans. Scintigraphic findings were compared to clinical follow up, histology or cultures. Results: Positive findings were found in 17 bone scans strongly suggesting loosening in 10 cases, infection of prosthesis in 4 cases and both loosening/infection in 3 cases. Bone scintigraphy was normal in 11pts. Scans of three pts with previously extracted hip prosthesis and scheduled for reimplatation, showed inhomogeneously and mildly increased uptake in femur. Most of scans classified as indeterminate (n=12) showed slightly increased tracer uptake in region of acetabular roof, greater or lesser tho chanter, suggesting bone remodeling due to the presence of implant, rather than loosening. Conclusion: 99m Tc-MDP bone scintigraphy had a significant role in assessing the painful joint prosthesis. Complementary diagnostic procedures should be considered in indeterminate scintiscans. (authors)

  2. Control and Evaluation of a Powered Transfemoral Prosthesis for Stair Ascent.

    Science.gov (United States)

    Ledoux, Elissa D; Goldfarb, Michael

    2017-07-01

    This paper assesses the metabolic effort exerted by three transfemoral amputees, when using a powered knee and ankle prosthesis for stair ascent, relative to ascending stairs with passive knee and ankle prostheses. The paper describes a controller that provides step-over stair ascent behavior reflective of healthy stair ascent biomechanics, and describes its implementation in a powered prosthesis prototype. Stair ascent experiments were performed with three unilateral transfemoral amputee subjects, comparing the oxygen consumption required to ascend stairs using the powered prosthesis (with a step-over gait), relative to using their daily-use energetically passive prostheses (with a step-to gait). Results indicate on average a 24% reduction in oxygen consumption and a 30% reduction in stair ascent timewhen using the powered prosthesis, relative to when using the passive prostheses. All subjects expressed a strong preference for ascending stairs using the powered prosthesis.

  3. Study of the radiation effect in breast implants

    International Nuclear Information System (INIS)

    Moreno T, L. R.; Ramirez R, A.

    2013-01-01

    This breast cancer is one of the most important death causes in women. Among the more frequently medical treatment for advanced breast cancer is the mastectomy. This situation leads to silicone implants as an esthetic option. There have been cases in patients with implants where cancer was frequently detected, in which a conventional radiotherapy is required. In this work is presented a study of the probable adverse effects caused by the application of high power X-rays (6-10 MV) to the silicone implants and to the surrounding tissues. In the research carried out at the clinic, none Bolus effect was detected in patients with implants. Our results prescribe that in the case of patients with implants and frequent breast cancer, the removal of implants is not necessary due radiotherapy works directly in the damaged tissues. (Author)

  4. Study of the radiation effect in breast implants

    Energy Technology Data Exchange (ETDEWEB)

    Moreno T, L. R.; Ramirez R, A., E-mail: lumor2000@yahoo.com.mx [Universidad Autonoma Metropolitana, Unidad Azcapotzalco, Departamento de Ciencias Basicas, Av. San Pablo No. 180, Col. Reynosa Tamaulipas, 02200 Mexico D. F. (Mexico)

    2013-10-01

    This breast cancer is one of the most important death causes in women. Among the more frequently medical treatment for advanced breast cancer is the mastectomy. This situation leads to silicone implants as an esthetic option. There have been cases in patients with implants where cancer was frequently detected, in which a conventional radiotherapy is required. In this work is presented a study of the probable adverse effects caused by the application of high power X-rays (6-10 MV) to the silicone implants and to the surrounding tissues. In the research carried out at the clinic, none Bolus effect was detected in patients with implants. Our results prescribe that in the case of patients with implants and frequent breast cancer, the removal of implants is not necessary due radiotherapy works directly in the damaged tissues. (Author)

  5. Electrochemical approach for monitoring the effect of anti tubulin drugs on breast cancer cells based on silicon nanograss electrodes.

    Science.gov (United States)

    Zanganeh, Somayeh; Khosravi, Safoora; Namdar, Naser; Amiri, Morteza Hassanpour; Gharooni, Milad; Abdolahad, Mohammad

    2016-09-28

    One of the most interested molecular research in the field of cancer detection is the mechanism of drug effect on cancer cells. Translating molecular evidence into electrochemical profiles would open new opportunities in cancer research. In this manner, applying nanostructures with anomalous physical and chemical properties as well as biocompatibility would be a suitable choice for the cell based electrochemical sensing. Silicon based nanostructure are the most interested nanomaterials used in electrochemical biosensors because of their compatibility with electronic fabrication process and well engineering in size and electrical properties. Here we apply silicon nanograss (SiNG) probing electrodes produced by reactive ion etching (RIE) on silicon wafer to electrochemically diagnose the effect of anticancer drugs on breast tumor cells. Paclitaxel (PTX) and mebendazole (MBZ) drugs have been used as polymerizing and depolymerizing agents of microtubules. PTX would perturb the anodic/cathodic responses of the cell-covered biosensor by binding phosphate groups to deformed proteins due to extracellular signal-regulated kinase (ERK(1/2)) pathway. MBZ induces accumulation of Cytochrome C in cytoplasm. Reduction of the mentioned agents in cytosol would change the ionic state of the cells monitored by silicon nanograss working electrodes (SiNGWEs). By extending the contacts with cancer cells, SiNGWEs can detect minor signal transduction and bio recognition events, resulting in precise biosensing. Effects of MBZ and PTX drugs, (with the concentrations of 2 nM and 0.1 nM, respectively) on electrochemical activity of MCF-7 cells are successfully recorded which are corroborated by confocal and flow cytometry assays. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation

    Directory of Open Access Journals (Sweden)

    Cheng Chen

    2016-04-01

    Full Text Available ABSTRACT INTRODUCTION: Maxillary defects are usually rehabilitated by a prosthetic obturator. OBJECTIVE: This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. METHODS: Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS. RESULTS: From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP, 11 (39% with an enhanced retentive obturator prosthesis with stud attachment (POP and 8 (28% with an enhanced retentive obturator prosthesis with magnetic attachment (POM. The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p < 0.05 among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p < 0.05 both in MOP and AOP groups. CONCLUSION: Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function.

  7. Local complications after cosmetic breast implant surgery in Finland

    DEFF Research Database (Denmark)

    Kulmala, Ilona; McLaughlin, Joseph K; Pakkanen, Matti

    2004-01-01

    Concerns regarding potential health effects of silicone breast implants have recently shifted from long-term illnesses to postoperative local complications. In this study, occurrence of local complications and treatment procedures were evaluated in a population of 685 Finnish women who received...... implantation. Most of the women were satisfied with the implantation, but only 40% considered the preoperative information on possible risks related to implantation as sufficient. With respect to the occurrence of local complications following cosmetic breast implantation, the findings of this study...... cosmetic silicone breast implants between 1968 and 2002. Patient records were abstracted, and additional information was gathered using a structured questionnaire that was mailed to 470 of the women in the cohort. Overall, 36% of the women had 1 or more diagnoses of postoperative complications...

  8. Use of Powered Prosthesis for Children with Upper Limb Deficiency at Hyogo Rehabilitation Center.

    Directory of Open Access Journals (Sweden)

    Mitsunori Toda

    Full Text Available There has been no research investigating the use of powered prosthetic for children in Japan.To gain better insight into the state of powered prosthesis usage and identify a ratio of rejection among children.Subjects were 37 unilateral below elbow amputees between the ages of 0 and 16 at the time of their first experienced fitting with a powered prosthesis at our Center. The information was collected from medical records and through face-to-face interviews, and we examined rejection rate and the factors affecting the use of powered prosthesis.The rate of discontinuation was 21.6% as 8 of the 37 children stopped using powered prosthesis. All of them were fitted their prosthesis after 2 years of age, and they rejected prosthesis between 5 to 19 years. We found that the level of amputation had no influence on the use of a powered prosthesis.Children fitted before 2 years of age tend to accept their powered prosthesis than those fitted after 2 years. Multidisciprinary team approach, adequate rehabilitation, detailed follow-up and involvement of parents are quite important for introducing powered prosthesis for children.

  9. Porous silicon advances in drug delivery and immunotherapy.

    Science.gov (United States)

    Savage, David J; Liu, Xuewu; Curley, Steven A; Ferrari, Mauro; Serda, Rita E

    2013-10-01

    Biomedical applications of porous silicon include drug delivery, imaging, diagnostics and immunotherapy. This review summarizes new silicon particle fabrication techniques, dynamics of cellular transport, advances in the multistage vector approach to drug delivery, and the use of porous silicon as immune adjuvants. Recent findings support superior therapeutic efficacy of the multistage vector approach over single particle drug delivery systems in mouse models of ovarian and breast cancer. With respect to vaccine development, multivalent presentation of pathogen-associated molecular patterns on the particle surface creates powerful platforms for immunotherapy, with the porous matrix able to carry both antigens and immune modulators. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Changes in performance over time while learning to use a myoelectric prosthesis

    NARCIS (Netherlands)

    Bouwsema, Hanneke; van der Sluis, Corry K.; Bongers, Raoul M.

    2014-01-01

    Background: Training increases the functional use of an upper limb prosthesis, but little is known about how people learn to use their prosthesis. The aim of this study was to describe the changes in performance with an upper limb myoelectric prosthesis during practice. The results provide a basis

  11. PIP breast implant removal: a study of 828 cases.

    Science.gov (United States)

    Oulharj, S; Pauchot, J; Tropet, Y

    2014-03-01

    In March, 2010, the French Health Products Safety Agency suspended the sale of prefilled silicone breast implants manufactured by Poly Implants Prosthèse Prothese (PIP) because of a high failure rate and the use of an inappropriate silicone gel that did not comply with CE marking. These findings led to an international medical crisis. In France, 30,000 female patients had PIP implants. In our Department, 1150 PIP breast implants had been implanted in 630 patients since 2001. A retrospective study was conducted to define the rupture rate of these implants and the complications that arise. The women included in the study underwent implant removal from May 2010 to September 2012 for preventive or curative reasons. Data were collected from medical records that included: results of clinical examination, breast ultrasound before removal, rates of implant rupture, results of biopsy of periprosthetic capsule and pericapsule tissue and postoperative complications. A total of 828 PIP breast implants were removed in 455 patients. The rate of ruptured implants was 7.73% (64/828), corresponding to 11.6% of patients. A periprosthetic effusion was associated with rupture in 44% of cases. Breast ultrasound indicated a rupture for 87 implants; 32% were true positives and 3% were false negatives. Periprosthetic capsule biopsy demonstrated the presence of a foreign body, which seemed to be silicone, in 26% of cases and the presence of inflammation in 13% of cases. No siliconoma-type lesion was identified in the pericapsular tissue at biopsy. A total of 14 implants presented perspiration at removal. A statistically significant difference was found between the rates of rupture for texturised implants as compared to the smooth-surfaced implants. There were eight post-revisional-surgery complications (1%) and three cases of breast adenocarcinoma. The preventive explantation of PIP breast implants is justified given the high failure rate (7.73%) and given patients' exposure to silicone

  12. Design of a power-asymmetric actuator for a transtibial prosthesis.

    Science.gov (United States)

    Bartlett, Harrison L; Lawson, Brian E; Goldfarb, Michael

    2017-07-01

    This paper presents the design and characterization of a power-asymmetric actuator for a transtibial prosthesis. The device is designed to provide the combination of: 1) joint locking, 2) high power dissipation, and 3) low power generation. This actuator functionality allows for a prosthesis to be designed with minimal mass and power consumption relative to a fully-powered robotic prosthesis while maintaining much of the functionality necessary for activities of daily living. The actuator achieves these design characteristics while maintaining a small form factor by leveraging a combination of electromechanical and hydraulic components. The design of the actuator is described herein, and results of an experimental characterization are provided that indicate that the actuator is capable of providing the functional capabilities required of an ankle prosthesis in a compact and lightweight package.

  13. [Surgery of the breast on transgender persons].

    Science.gov (United States)

    Karhunen-Enckell, Ulla; Kolehmainen, Maija; Kääriäinen, Minna; Suominen, Sinikka

    2015-01-01

    For a female-to-male transgender person, mastectomy is the most important procedure making the social interaction easier. Along with the size of the breasts, the quantity and quality of skin will influence the selection of surgical technique. Although complications are rare, corrective surgery is performed for as many as 40% of the patients. Of male-to-female transsexual persons, 60 to 70% opt for breast enlargement. Breast enlargement can be carried out by using either silicone implants or fat transplantation. Since the surgical procedures on breasts are irreversible, their implementation requires confirmation of the diagnosis of transsexualism by a multidisciplinary team.

  14. Cranioplasty prosthesis manufacturing based on reverse engineering technology

    Science.gov (United States)

    Chrzan, Robert; Urbanik, Andrzej; Karbowski, Krzysztof; Moskała, Marek; Polak, Jarosław; Pyrich, Marek

    2012-01-01

    Summary Background Most patients with large focal skull bone loss after craniectomy are referred for cranioplasty. Reverse engineering is a technology which creates a computer-aided design (CAD) model of a real structure. Rapid prototyping is a technology which produces physical objects from virtual CAD models. The aim of this study was to assess the clinical usefulness of these technologies in cranioplasty prosthesis manufacturing. Material/Methods CT was performed on 19 patients with focal skull bone loss after craniectomy, using a dedicated protocol. A material model of skull deficit was produced using computer numerical control (CNC) milling, and individually pre-operatively adjusted polypropylene-polyester prosthesis was prepared. In a control group of 20 patients a prosthesis was manually adjusted to each patient by a neurosurgeon during surgery, without using CT-based reverse engineering/rapid prototyping. In each case, the prosthesis was implanted into the patient. The mean operating times in both groups were compared. Results In the group of patients with reverse engineering/rapid prototyping-based cranioplasty, the mean operating time was shorter (120.3 min) compared to that in the control group (136.5 min). The neurosurgeons found the new technology particularly useful in more complicated bone deficits with different curvatures in various planes. Conclusions Reverse engineering and rapid prototyping may reduce the time needed for cranioplasty neurosurgery and improve the prosthesis fitting. Such technologies may utilize data obtained by commonly used spiral CT scanners. The manufacturing of individually adjusted prostheses should be commonly used in patients planned for cranioplasty with synthetic material. PMID:22207125

  15. Function of obturator prosthesis after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chen, Cheng; Ren, Wenhao; Gao, Ling; Cheng, Zheng; Zhang, Linmei; Li, Shaoming; Zhi, Pro Ke-qian

    2016-01-01

    Maxillary defects are usually rehabilitated by a prosthetic obturator. This study aimed to evaluate the functioning of obturators prosthesis in patients with unilateral defects after maxillectomy. Of 49 patients, 28 underwent to maxillectomy as a result of tumor ablative surgery, and acquired unilateral maxillary defects. Evaluation of the function was performed by applying the Obturator Functional Scale (OFS). From a total of 49 patients, 28 were treated as follows: 9 with a conventional retained obturator prosthesis (COP), 11 (39%) with an enhanced retentive obturator prosthesis with stud attachment (POP) and 8 (28%) with an enhanced retentive obturator prosthesis with magnetic attachment (POM). The mean OFS score was 80. Scores on functions of speech, swallowing and chewing reached statistical significances (p<0.05) among these three subgroups. Comparing COP and MOP groups, the scores of OFS in the domains of "Speech-ability to speak in public" and "Swallowing-leakage with liquids" were significantly higher in AOP group. Comparing COP group, the scores of OFS in "Swallowing-leakage with solid" and "Chewing/eating" domains were increased significantly (p<0.05) both in MOP and AOP groups. Obturator prosthesis improves oral function of patients after maxillary defects; the retention of the obturator prosthesis enhanced by the addition of attachments showed more benefits in oral function. Copyright © 2015 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  16. 3D silicon breast surface mapping via structured light profilometry

    Science.gov (United States)

    Vairavan, R.; Ong, N. R.; Sauli, Z.; Kirtsaeng, S.; Sakuntasathien, S.; Shahimin, M. M.; Alcain, J. B.; Lai, S. L.; Paitong, P.; Retnasamy, V.

    2017-09-01

    Digital fringe projection technique is one of the promising optical methods for 3D surface imaging as it demonstrates non contact and non invasive characteristics. The potential of this technique matches the requirement for human body evaluation, as it is vital for disease diagnosis and for treatment option selection. Thus, the digital fringe projection has addressed this requirement with its wide clinical related application and studies. However, the application of this technique for 3D surface mapping of the breast is very minimal. Hence, in this work, the application of digital fringe projection for 3D breast surface mapping is reported. Phase shift fringe projection technique was utilized to perform the 3D breast surface mapping. Maiden results have confirmed the feasibility of using the digital fringe projection method for 3D surface mapping of the breast and it can be extended for breast cancer detection.

  17. High-grade Angiosarcoma Associated with Ruptured Breast Implants

    Directory of Open Access Journals (Sweden)

    Nicolas R. Smoll, MBBS

    2013-04-01

    Full Text Available Summary: Since the serendipitous discovery that implanted polymers cause sarcomas in rats, much research has been conducted to prove or disprove a link between silicone breast implants and/or polymer-based materials and breast cancer. In light of an initial report that 35% of rats implanted with a variety of polymers developed fibrosarcomas, we report a case of primary angiosarcoma found in a patient presenting with bilateral rupture of gel-filled breast implants.

  18. Design and Characterization of a Quasi-Passive Pneumatic Foot-Ankle Prosthesis.

    Science.gov (United States)

    Lee, Jeffrey D; Mooney, Luke M; Rouse, Elliott J

    2017-07-01

    The majority of commercially available passive prosthetic feet are not capable of providing joint mechanics that match that of the intact human ankle. Due to their cantilever design, their stiffness characteristics contrast with what has been observed in the biological ankle, namely, an increase in stiffness during the stance phase of walking. In this paper, we introduce the design and control of a pneumatic foot-ankle prosthesis that attempts to provide biomimetic mechanics. The prosthesis is comprised of a pneumatic cylinder in series with a fiberglass leaf spring, and a solenoid valve to control the flow of air between the two sides of the cylinder. The solenoid valve acts as a mechanical clutch, enabling resetting of the ankle's equilibrium position. By adjusting the pressure inside the cylinder, the prosthesis can be customized to provide a range of ankle mechanics. A mechanical testing machine is used to compare the torque-angle curve of the pneumatic prosthesis with a low-profile passive prosthetic foot. Finally, data are presented of one transtibial amputee walking with the prosthesis at 1.2 m/s. The testing shows that the pneumatic prosthesis is capable of providing an appropriate range of motion as well a maximum torque of 94 Nm, while returning approximately 11.5 J of energy.

  19. Doppler derived gradient of ST Jude Mechanical Prosthesis, early postoperative assessment

    International Nuclear Information System (INIS)

    Shaikh, A.H.; Hanif, B.; Adil, A.; Hashimi, S.; Qazi, H.A.; Mujtaba, I.

    2010-01-01

    Objective: To determine the doppler derived mean gradients of St Jude mechanical prosthesis in early postoperative period in patients undergoing valve replacement at a tertiary care cardiac centre. Methods: Medical records of 190 consecutive patients who underwent 233 mitral, aortic or dual (mitral and aortic) valve replacement by St Jude bileaflet mechanical prosthesis at Tabba Heart Institute, between March 2006 to December 2008 were reviewed. Doppler derived mean gradients were assessed predischarge and recorded. Results: There were 98 (51.5%) males and 92 (48.5%) females in the study cohort. The mean age was 40 +- 14 years. Of the total, 101 (53%) had mitral, 46 (24.2%) had aortic and 43 (22.6%) patients had dual valve replacement. Doppler derived mean gradient was assessed across 144 mitral and 89 aortic St Jude mechanical prosthesis. Doppler derived mean gradient for St Jude mitral prosthesis was 3.5 mm Hg and for St Jude aortic prosthesis was 10.2 mm Hg. Conclusions: The study determines baseline gradients across mitral and aortic St Jude mechanical prosthesis in our population. These can be used as reference gradients to assess St Jude prosthetic valve function in patients who did not have early postoperative doppler assessment. (author)

  20. The reverse shoulder prosthesis: a review of imaging features and complications

    Energy Technology Data Exchange (ETDEWEB)

    McFarland, Edward G.; Sanguanjit, Prakasit; Tasaki, Atsushi [Johns Hopkins University, Department of Orthopedic Surgery, Lutherville, MD (United States); Keyurapan, Ekavit [Mahidol University, Department of Orthopaedic Surgery, Bangkok (Thailand); Fishman, Elliot K.; Fayad, Laura M. [Johns Hopkins Medical Institutions, Johns Hopkins University, Department of Radiology and Radiological Sciences, Baltimore, MD (United States)

    2006-07-15

    The reverse shoulder prosthesis is a prosthesis that has been in clinical use in Europe since 1985 and was approved for use in the United States in 2004. This unique prosthesis has a baseplate attached to the glenoid, which holds a spherical component, while the humeral component includes a polyethylene insert that is flat. This design is the ''reverse'' configuration of that seen with a conventional arthroplasty, in which the spherical component is part of the humeral component. The indications for the reverse prosthesis are: (1) painful arthritis associated with irreparable rotator cuff tears (cuff tear arthropathy), (2) failed hemiarthroplasty with irreparable rotator cuff tears, (3) pseudoparalysis due to massive, irreparable rotator cuff tears, (4) some reconstructions after tumor resection, and (5) some fractures of the shoulder not repairable or reconstructable with other techniques. This prosthesis can produce a significant reduction in pain and some improvement in function for most of the indications mentioned. However, the unique configuration and the challenge of its insertion can result in a high incidence of a wide variety of unusual complications. Some of these complications, such as dislocation of the components, are similar to conventional shoulder replacement. Other complications, such as notching of the scapula and acromial stress fractures, are unique to this prosthesis. (orig.)

  1. The reverse shoulder prosthesis: a review of imaging features and complications

    International Nuclear Information System (INIS)

    McFarland, Edward G.; Sanguanjit, Prakasit; Tasaki, Atsushi; Keyurapan, Ekavit; Fishman, Elliot K.; Fayad, Laura M.

    2006-01-01

    The reverse shoulder prosthesis is a prosthesis that has been in clinical use in Europe since 1985 and was approved for use in the United States in 2004. This unique prosthesis has a baseplate attached to the glenoid, which holds a spherical component, while the humeral component includes a polyethylene insert that is flat. This design is the ''reverse'' configuration of that seen with a conventional arthroplasty, in which the spherical component is part of the humeral component. The indications for the reverse prosthesis are: (1) painful arthritis associated with irreparable rotator cuff tears (cuff tear arthropathy), (2) failed hemiarthroplasty with irreparable rotator cuff tears, (3) pseudoparalysis due to massive, irreparable rotator cuff tears, (4) some reconstructions after tumor resection, and (5) some fractures of the shoulder not repairable or reconstructable with other techniques. This prosthesis can produce a significant reduction in pain and some improvement in function for most of the indications mentioned. However, the unique configuration and the challenge of its insertion can result in a high incidence of a wide variety of unusual complications. Some of these complications, such as dislocation of the components, are similar to conventional shoulder replacement. Other complications, such as notching of the scapula and acromial stress fractures, are unique to this prosthesis. (orig.)

  2. Association between dental prosthesis need, nutritional status and quality of life of elderly subjects

    DEFF Research Database (Denmark)

    Pillai, Rajath; Mathur, Vijay Prakash; Jain, Veena

    2015-01-01

    clinic were recruited in the study. Mini-nutritional assessment (MNA), geriatric oral health assessment (GOHAI) indices, prosthesis need according to WHO criteria, and prosthesis want was recorded along with age, gender, socioeconomic status and posterior occluding pair. RESULTS: Significant associations......To determine the effect of prosthesis need on nutritional status and oral health-related quality of life (OHrQoL) in elderly and to check the disparity between prosthesis need and prosthesis want in the Indian elderly. METHODS: A total of 946 geriatric participants reporting to a geriatric medicine...

  3. Breast scintigraphy today: indications and limitations

    International Nuclear Information System (INIS)

    Schillaci, Orazio; Buscombe, John R.

    2004-01-01

    Breast carcinoma is the most common neoplasm found among women in the Western world. Mammography (MM) is the most widely used diagnostic imaging method for screening and diagnosing breast cancer. However, despite technical improvements in recent years, MM has known diagnostic limits; consequently not all breast carcinomas are identified on mammograms, especially if the breast is dense, there is a breast prosthesis or the patient has previously undergone radiation, surgery or biopsy. In addition, the mammographic images of benign and malignant lesions can be similar. Therefore, abnormalities detected on MM frequently result in negative biopsies. Scintimammography (SM) is the functional imaging study of the breast using primarily the radiopharmaceuticals 99m Tc-sestamibi and 99m Tc-tetrofosmin. The main advantage of SM is that its functional basis makes this technique a useful complement to MM. SM resolves some of the main limitations of MM as it is not affected by changes in breast morphology. Several single-site and multi-centre studies have demonstrated that SM has an improved specificity compared with MM, because it is better able to distinguish malignant from benign breast lesions. Interestingly, except in smaller lesions, a higher sensitivity has been recorded for SM than for MM in most of these studies as well. Adjunctive use of SM when MM is equivocal can reduce the number of unnecessary breast biopsies and identify previously unexpected sites of breast cancer. SM appears unaffected by the anatomical changes seen following chemotherapy and radiotherapy, and so this technique can be particularly useful in monitoring the treatment of breast cancer patients, especially when breast-conserving treatment is given. The main limitation to SM has been the sub-optimal resolution of the standard Anger gamma camera, which makes it difficult to detect lesions of less than 10 mm; however, the development of high-resolution breast-dedicated gamma cameras may offer

  4. Breast scintigraphy today: indications and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [Department of Biopathology and Diagnostic Imaging, University ' ' Tor Vergata' ' , Rome (Italy); Buscombe, John R. [Department of Nuclear Medicine, Royal Free Hospital, London (United Kingdom)

    2004-06-01

    Breast carcinoma is the most common neoplasm found among women in the Western world. Mammography (MM) is the most widely used diagnostic imaging method for screening and diagnosing breast cancer. However, despite technical improvements in recent years, MM has known diagnostic limits; consequently not all breast carcinomas are identified on mammograms, especially if the breast is dense, there is a breast prosthesis or the patient has previously undergone radiation, surgery or biopsy. In addition, the mammographic images of benign and malignant lesions can be similar. Therefore, abnormalities detected on MM frequently result in negative biopsies. Scintimammography (SM) is the functional imaging study of the breast using primarily the radiopharmaceuticals {sup 99m}Tc-sestamibi and {sup 99m}Tc-tetrofosmin. The main advantage of SM is that its functional basis makes this technique a useful complement to MM. SM resolves some of the main limitations of MM as it is not affected by changes in breast morphology. Several single-site and multi-centre studies have demonstrated that SM has an improved specificity compared with MM, because it is better able to distinguish malignant from benign breast lesions. Interestingly, except in smaller lesions, a higher sensitivity has been recorded for SM than for MM in most of these studies as well. Adjunctive use of SM when MM is equivocal can reduce the number of unnecessary breast biopsies and identify previously unexpected sites of breast cancer. SM appears unaffected by the anatomical changes seen following chemotherapy and radiotherapy, and so this technique can be particularly useful in monitoring the treatment of breast cancer patients, especially when breast-conserving treatment is given. The main limitation to SM has been the sub-optimal resolution of the standard Anger gamma camera, which makes it difficult to detect lesions of less than 10 mm; however, the development of high-resolution breast-dedicated gamma cameras may offer

  5. BIOLOGICAL AND SYNTHETIC MATERIALS IN RECONSTRUCTIVE SURGERY FOR BREAST CANCER TREATMENT (LITERATURE REVIEW

    Directory of Open Access Journals (Sweden)

    A. D. Zikiryakhodzhaev

    2018-01-01

    Full Text Available During the last years has been a worldwide trend towards rejuvenating breast cancer, and the evolution of reconstructive breast surgery is proceeding at a rapid pace. The surgical method is the primary method in the combined and complex treatment of breast cancer, and radical mastectomy is still the main option for surgical treatment in most Russian clinics. Most women who need a mastectomy prefer a one-stage breast reconstruction, because the woman is quickly rehabilitated psychologically and physically after this operation. Nevertheless, the use of silicone endoprostheses did not solve the problems of breast reconstruction in combined treatment in oncology. The issue remains unresolved of various complications, related not only to infections, but also to the development of capsular contracture after radiotherapy. Many patients with a one-stage breast reconstruction using a silicone endoprostheses lack the volume of their own tissues for reliable shelter of the endoprosthesis. In such cases, synthetic reticulated implants, biological implants or autologous flaps are used to cover and strengthen the lower slope of the reconstructed breast.

  6. Smartphone supported upper limb prosthesis

    Directory of Open Access Journals (Sweden)

    Hepp D.

    2015-09-01

    Full Text Available State of the art upper limb prostheses offer up to six active DoFs (degrees of freedom and are controlled using different grip patterns. This low number of DoFs combined with a machine-human-interface which does not provide control over all DoFs separately result in a lack of usability for the patient. The aim of this novel upper limb prosthesis is both offering simplified control possibilities for changing grip patterns depending on the patients’ priorities and the improvement of grasp capability. Design development followed the design process requirements given by the European Medical Device Directive 93/42 ECC and was structured into the topics mechanics, software and drive technology. First user needs were identified by literature research and by patient feedback. Consequently, concepts were evaluated against technical and usability requirements. A first evaluation prototype with one active DoF per finger was manufactured. In a second step a test setup with two active DoF per finger was designed. The prototype is connected to an Android based smartphone application. Two main grip patterns can be preselected in the software application and afterwards changed and used by the EMG signal. Three different control algorithms can be selected: “all-day”, “fine” and “tired muscle”. Further parameters can be adjusted to customize the prosthesis to the patients’ needs. First patient feedback certified the prosthesis an improved level of handling compared to the existing devices. Using the two DoF test setup, the possibilities of finger control with a neural network are evaluated at the moment. In a first user feedback test, the smartphone based software application increased the device usability, e.g. the change within preselected grip patterns and the “tired muscle” algorithm. Although the overall software application was positively rated, the handling of the prosthesis itself needs to be proven within a patient study to be

  7. Fabrication of custom made ocular prosthesis with three different ...

    African Journals Online (AJOL)

    Loss of eye has a bad effect on the psychology of the patient. Eye prosthesis is fabricated to regain the patient's confidence by meticulous replacement of the missing eye. Immediate fitting of an anophthalmic socket with an artificial eye may not always be possible, and a delayed prosthesis delivery may result in settling and ...

  8. Simplified technique for orbital prosthesis fabrication: a clinical report.

    Science.gov (United States)

    Veerareddy, Chandrika; Nair, K Chandrasekharan; Reddy, G Ramaswamy

    2012-10-01

    Loss of orbital content can cause functional impairment, disfigurement of the face, and psychological distress. Rehabilitation of an orbital defect is a complex task, and if reconstruction by plastic surgery is not possible or not desired by the patient, the defect can be rehabilitated by an orbital prosthesis. The prosthetic rehabilitation in such cases depends on the precisely retained, user-friendly removable maxillofacial prosthesis. Many times, making an impression of the orbital area with an accurate record of surface details can be a difficult procedure. The critical areas are making a facial moulage, mold preparation, and attaching the retention device, particularly when eyeglass frames are used. This case focuses on these hindrance factors. A simple basket was used for the impression tray to obtain the facial moulage. A putty mold was used, and attachment of the prosthesis to a retention device was accomplished with positional distance. This method proves to be an economical and simple way of making an orbital prosthesis. © 2012 by the American College of Prosthodontists.

  9. [Rehabilitation by hollow obturator prosthesis immediately after total maxillectomy for malignant tumor].

    Science.gov (United States)

    Li, Xiao-ye; Yan, Ai-hui; Hao, Shuai; Li, Wei; Jiang, Xue-jun; Lu, Li; Qin, Xing-jun; Yan, Hai-xin

    2011-05-01

    The feasibility and clinical effects of hollow obturator prosthesis for the repair of maxillofacial defect immediately after maxillectomy for cancer were assessed. Thirteen patients with T3-4aN0M0 maxillary neoplasm were treated by the prostheses immediately after maxillectomy. According to the 3D-CT reconstruction of nasal sinus, the 3D stereoscopic prototype was constructed before the surgery. Simulating surgery with Surgicare 5.0 software and then the prosthesis 3D stereoscopic model was shaped. The prosthesis was made quickly and precisely with methacrylate resins according to the model and the print mold before surgery, with supplementary tooth at the bottom of prosthesis. In the surgery, the prosthesis was installed instantly after maxillectomy. The patients were followed up at 1, 3 and 6 month after the surgery, respectively. The facial features and the pronunciation clarity were examined and the questionnaires were carried out in the patients, with comparation by paired t-test. The hollow obturator prosthesis would be replaced by permanent prosthesis made of methacrylate resins at 6 month after the surgery. The hollow obturator prostheses were installed accurately and maxillofacial defects were repaired immediately after maxillectomy in the 13 patients. Postoperative follow-up showed there were significant differences in eyeball sagging (t = 4.67, P maxillectomy can improve survival quality of patient.

  10. Nonexpansive immediate breast reconstruction using human acellular tissue matrix graft (AlloDerm).

    Science.gov (United States)

    Salzberg, C Andrew

    2006-07-01

    Immediate breast reconstruction has become a standard of care following mastectomy for cancer, largely due to improved esthetic and psychologic outcomes achieved with this technique. However, the current historical standards--transverse rectus abdominis myocutaneous flap reconstruction and expander--implant surgery-still have limitations as regards patient morbidity, short-term body-image improvements, and even cost. To address these shortcomings, we employ a novel concept of human tissue replacement to enhance breast shape and provide total coverage, enabling immediate mound reconstruction without the need for breast expansion prior to permanent implant placement. AlloDerm (human acellular tissue matrix) is a human-derived graft tissue with extensive experience in various settings of skin and soft tissue replacement surgery. This report describes the success using acellular tissue matrix to provide total coverage over the prosthesis in immediate reconstruction, with limited muscle dissection. In this population, 49 patients (76 breasts) successfully underwent the acellular tissue matrix-based immediate reconstruction, resulting in durable breast reconstruction with good symmetry. These findings may predict that acellular tissue matrix-supplemented immediate breast reconstruction will become a new technique for the immediate reconstruction of the postmastectomy breast.

  11. Treatment of femoral neck fracture by Moore Prosthesis in Cotonou ...

    African Journals Online (AJOL)

    Treatment of femoral neck fracture by Moore Prosthesis in Cotonou. AHM Akue, M Lawson, S Madougou, R Zannou, J Padonou. Abstract. Keywords: Benin; hip; Moore prosthesis; results. Full Text: EMAIL FULL TEXT EMAIL FULL TEXT · DOWNLOAD FULL TEXT DOWNLOAD FULL TEXT.

  12. Analysis of the mechanical behavior of the Nijdam voice prosthesis

    NARCIS (Netherlands)

    Verkerke, GJ; deVries, MP; Schutte, HK; vandenHoogen, FJA; Rakhorst, G

    1997-01-01

    The valveless Nijdam prosthesis is a new voice prosthesis for laryngectomized patients using tracheoesophageal speech. An ''umbrella-like hat'' covers the esophageal side of the tracheoesophageal fistula and is deformed during speech by air pressure. To decrease pressure loss during speech, a good

  13. The clinical implications of poly implant prothèse breast implants: an overview.

    Science.gov (United States)

    Wazir, Umar; Kasem, Abdul; Mokbel, Kefah

    2015-01-01

    Mammary implants marketed by Poly Implant Prothèse (PIP) were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635) for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

  14. The Clinical Implications of Poly Implant Prothèse Breast Implants: An Overview

    Directory of Open Access Journals (Sweden)

    Umar Wazir

    2015-01-01

    Full Text Available Mammary implants marketed by Poly Implant Prothèse (PIP were found to contain industrial grade silicone and this caused heightened anxiety and extensive publicity regarding their safety in humans. These implants were used in a large number of patients worldwide for augmentation or breast reconstruction. We reviewed articles identified by searches of Medline, PubMed, Embase, and Google Scholar databases up to May 2014 using the terms: "PIP", "Poly Implant Prothèse", "breast implants" and "augmentation mammoplasty" "siloxanes" or "silicone". In addition the websites of regulating bodies in Europe, USA, and Australia were searched for reports related to PIP mammary implants. PIP mammary implants are more likely to rupture than other implants and can cause adverse effects in the short to the medium term related to the symptoms of rupture such as pain, lumps in the breast and axilla and anxiety. Based on peer-reviewed published studies we have calculated an overall rupture rate of 14.5% (383/2,635 for PIP implants. However, there is no evidence that PIP implant rupture causes long-term adverse health effects in humans so far. Silicone lymphadenopathy represents a foreign body reaction and should be treated conservatively. The long-term adverse effects usually arise from inappropriate extensive surgery, such as axillary lymph node dissection or extensive resection of breast tissue due to silicone leakage.

  15. Antibiotic Prophylaxis after Immediate Breast Reconstruction: The Reality of Its Efficacy.

    Science.gov (United States)

    Ranganathan, Kavitha; Sears, Erika D; Zhong, Lin; Chung, Ting-Ting; Chung, Kevin C; Kozlow, Jeffrey H; Momoh, Adeyiza O; Waljee, Jennifer F

    2018-04-01

    Numerous techniques are used to prevent infection after immediate implant-based breast reconstruction. Postoperative antibiotic prophylaxis is commonly prescribed to decrease the risk of reconstructive failure, despite conflicting evidence regarding its effectiveness. The authors studied whether postoperative antibiotic prophylaxis decreases the risk of infection-related explantation in the setting of immediate prosthesis-based breast reconstruction. Using Truven MarketScan databases, the authors identified all patients who underwent immediate implant reconstruction between January of 2010 and June of 2014 with at least 6 months of follow-up. Postoperative antibiotic prophylaxis was defined as any oral antibiotic course to be taken postoperatively based on prescriptions filled within 14 days preoperatively through 24 hours after discharge. Reconstructive failure, defined as explantation because of infection, was the primary outcome. Secondary outcomes of interest included wound complications, infection, and readmission for infection. Multivariable regression analyses controlled for demographic variables/comorbidities. Of the 7443 patients, 6049 (81 percent) filled prescriptions for postoperative antibiotic prophylaxis. These patients were equally likely to develop a wound complication (OR, 0.93; 95 percent CI, 0.71 to 1.23) or infection (OR, 0.89; 95 percent CI, 0.70 to 1.14), undergo explantation because of infection (OR, 0.82; 95 percent CI, 0.57 to 1.18), or require readmission for infection (OR, 1.21; 95 percent CI, 0.82 to 1.78) compared with those who did not receive antibiotics. There was no significant difference in the risk of infection-related outcomes based on postoperative antibiotic prophylaxis duration. Postoperative antibiotic prophylaxis was not associated with a reduced risk of infection or explantation following prosthesis-based breast reconstruction. Given rising rates of antibiotic resistance, focusing instead on technical considerations and the

  16. Mastication improvement after partial implant-supported prosthesis use.

    Science.gov (United States)

    Gonçalves, T M S V; Campos, C H; Gonçalves, G M; de Moraes, M; Rodrigues Garcia, R C M

    2013-12-01

    Partially edentulous patients may be rehabilitated by the placement of removable dental prostheses, implant-supported removable dental prostheses, or partial implant fixed dental prostheses. However, it is unclear the impact of each prosthesis type over the masticatory aspects, which represents the objective of this paired clinical trial. Twelve patients sequentially received and used each of these 3 prosthesis types for 2 months, after which maximum bite force was assessed by a strain sensor and food comminution index was determined with the sieving method. Masseter and temporal muscle thicknesses during rest and maximal clenching were also evaluated by ultrasonography. Each maxillary arch received a new complete denture that was used throughout the study. Data were analyzed by analysis of variance for repeated measures, followed by the Tukey test (p mastication, and the magnitude of this effect was related to prosthesis type.

  17. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive......: A total of 173 patients were diagnosed with SVD by echocardiography. Of these, 64 (11%) patients had severe SVD and 109 (19%) patients moderate SVD. Severe SVD was associated with the age of the prosthesis and small prosthesis size [Size 21: hazard ratio (95% confidence interval, CI) 2.72 (0.97-8.56), P...

  18. Prosthesis infections after orthopedic joint replacement: the possible role of bacterial biofilms

    Directory of Open Access Journals (Sweden)

    Zhijun Song

    2013-06-01

    Full Text Available Prosthesis-related infection is a serious complication for patients after orthopedic joint replacement, which is currently difficult to treat with antibiotic therapy. Consequently, in most cases, removal of the infected prosthesis is the only solution to cure the infection. It is, therefore, important to understand the comprehensive interaction between the microbiological situation and the host immune responses that lead to prosthesis infections. Evidence indicates that prosthesis infections are actually biofilm-correlated infections that are highly resistant to antibiotic treatment and the host immune responses. The authors reviewed the related literature in the context of their clinical experience, and discussed the possible etiology and mechanism leading to the infections, especially problems related to bacterial biofilm, and prophylaxis and treatment of infection, including both microbiological and surgical measures. Recent progress in research into bacterial biofilm and possible future treatment options of prosthesis-related infections are discussed.

  19. Outcome of total knee arthroplasty with insall burstein-11 prosthesis

    International Nuclear Information System (INIS)

    Siddiq, M.Z.; Qayum, H.

    2006-01-01

    Patients with severe degenerative knee joint disease often require knee arthroplasty to reduce pain, improve stability and restore function. Insall Burstein II prosthesis is posteriorly stabilized condylar prosthesis, which provide posterior cruciate ligament substitution. It was designed to improve range of motion, stair climbing ability and to prevent posterior subluxation. Evaluate the functional outcome of total knee arthroplasty with IB II prosthesis and Evaluate the alignment of prosthetic components by radiological parameters and its correlation with functional outcome. Sixty knees of sixty patients were replaced by using Insall Burstein II prosthesis. Postoperative radiographs were evaluated for alignment of knee and prosthetic components by criteria selected from knee society roentogenographic evaluation system. Functional outcome was evaluated by rationale of knee society knee rating system. Prosthetic component was aligned in 93% and mal-alignment in 7% of the cases. There was significant improvement in functions core from mean score 33.83 +-15.5 to 59.5+-17.7 and knee score from 37 +- 12.5 to 76.4 +-2.2. Postoperative functional score was found correlated with alignment significantly. Conclusion: Total knee arthroplasty with I-B-II prosthesis is a safe durable and predictable procedure with proper surgical technique and expertise good alignment and satisfactory functional out come can be achieved. (author)

  20. Breast implants and breast cancer: a review of incidence, detection, mortality, and survival.

    Science.gov (United States)

    Deapen, Dennis

    2007-12-01

    Soon after breast implants were commercially introduced over 30 years ago, questions about potential carcinogenicity were raised. Animal experiments dating back to the mid-twentieth century demonstrated that foreign body implantation of many materials, including silicone, can induce sarcomas. Indeed, female breast cancer incidence rates in the United States have increased substantially over that period. Of the several published studies from various countries that have formally investigated the risk of breast cancer among augmentation mammaplasty patients, none show any evidence of increased risk. In fact, most find lower than expected risk, some with statistically significant reductions. Similarly, breast cancer mortality among these patients is generally found to be below that expected of other similar women. Delayed detection of breast cancer is a concern for these patients because implants can interfere with mammography. However, using indicators such as stage at diagnosis and tumor size, current research shows that augmentation patients do not experience delayed detection. Furthermore, several comparisons of post-breast cancer survival of augmented versus nonaugmented patients have found no significant differences. In summary, breast implants are not associated with an increased risk of breast cancer incidence or death, and these patients do not experience delayed detection or poorer post-breast cancer survival.

  1. MR imaging of breast implants.

    Science.gov (United States)

    Gorczyca, D P

    1994-11-01

    MR imaging has proved to be an excellent imaging modality in locating free silicone and evaluating an implant for rupture, with a sensitivity of approximately 94% and specificity of 97%. Silicone has a unique MR resonance frequency and long T1 and T2 relaxation times, which allows several MR sequences to provide excellent diagnostic images. The most commonly used sequences include T2-weighted, STIR, and chemical shift imaging (Figs. 3, 13, and 14). The T2-weighted and STIR sequences are often used in conjunction with chemical water suppression. The most reliable findings on MR images for detection of implant rupture include identification of the collapsed implant shell (linguine sign) and free silicone within the breast parenchyma.

  2. Fringe projection application for surface variation analysis on helical shaped silicon breast

    Science.gov (United States)

    Vairavan, R.; Ong, N. R.; Sauli, Z.; Shahimin, M. M.; Kirtsaeng, S.; Sakuntasathien, S.; Alcain, J. B.; Paitong, P.; Retnasamy, V.

    2017-09-01

    Breast carcinoma is rated as a second collective cause of cancer associated death among adult females. Detection of the disease at an early stage would enhance the chance for survival. Established detection methods such as mammography, ultrasound and MRI are classified as non invasive breast cancer detection modality, but however they are not entire non-invasive as physical contact still occurs to the breast. Thus requirement for a complete non invasive and non contact is evident. Therefore, in this work, a novel application of digital fringe projection for early detection of breast cancer based on breast surface analysis is reported. Phase shift fringe projection technique and pixel tracing method was utilized to analyze the breast surface change due to the incidence of breast lump. Results have shown that the digital fringe projection is capable in detecting the existence of 1 cm sized lump within the breast sample.

  3. Acetabular prosthesis: Proff of migration with ruler and pencil?

    International Nuclear Information System (INIS)

    Diederichs, C.G.; Fischer, U.; Vosshenrich, R.

    1993-01-01

    Conventional X-ray films were made with varying degrees of tilt of a pelvic phantom containing an acetabular prosthesis. The position of the prosthesis was then reconstructed graphically. The measurement errors were calculated and an estimate was made for the tilt. There is a linear correlation between the measurement error and the tilt of the prosthesis. Therefore a tilt dependent maximum error can be calculated. This error is very small for small degrees of tilt, so that acetabular migration can in this instance be evaluated with greater confidence than with other graphical methods. The error also correlates with the determination of the selected region of the acetabulum, but not with the position of the central focus spot or image magnification. (orig.) [de

  4. [Imaging evaluation on adaptability of proximal humeral anatomy after shoulder replacement with individualized shoulder prosthesis].

    Science.gov (United States)

    Shi, Youxing; Tang, Kanglai; Yuan, Chengsong; Tao, Xu; Wang, Huaqing; Chen, Bo; Guo, Yupeng

    2015-03-24

    Modern shoulder prosthesis has evolved through four generations. And the fourth generation technology has a core three-dimensional design of restoring 3D reconstruction of proximal humeral anatomy. Thus a new shoulder prosthesis is developed on the basis of the technology of 3D prosthesis. Assessment of whether shoulder prosthesis can restore individualized reconstruction of proximal humeral anatomy is based on the adaptability of proximal humeral anatomy. To evaluate the adaptability of proximal humeral anatomy through measuring the parameters of proximal humeral anatomy after shoulder replacement with individualized shoulder prosthesis and compare with normal data. The parameters of proximal humeral anatomy were analyzed and evaluated for a total of 12 cases undergoing shoulder replacement with individualized shoulder prosthesis. The relevant anatomical parameters included neck-shaft angle (NSA), retroversion angle (RA), humeral head height (HH) and humeral head diameter (HD). And the anatomical parameters were compared with the data from normal side. All underwent shoulder replacement with individualized shoulder prosthesis. The postoperative parameters of proximal humeral anatomy were compared with those of normal side. And the difference of NSA was 0.05). Individualized shoulder prosthesis has excellent adaptability to shoulder. All core parameters are freely adjustable and specification models may be optimized. With matching tools, individualized shoulder prosthesis improves the accuracy and reliability in shoulder replacement.

  5. Rehabilitation of orbital cavity after orbital exenteration using polymethyl methacrylate orbital prosthesis

    Directory of Open Access Journals (Sweden)

    Sumeet Jain

    2016-01-01

    Full Text Available Squamous cell carcinoma of the eyelid is the second most common malignant neoplasm of the eye with the incidence of 0.09 and 2.42 cases/100 000 people. Orbital invasion is a rare complication but, if recognized early, can be treated effectively with exenteration. Although with advancements in technology such as computer-aided design and computer-aided manufacturing, material science, and retentive methods like implants, orbital prosthesis with stock ocular prosthesis made of methyl methacrylate retained by anatomic undercuts is quiet effective and should not be overlooked and forgotten. This clinical report describes prosthetic rehabilitation of two male patients with polymethyl methacrylate resin orbital prosthesis after orbital exenteration, for squamous cell carcinoma of the upper eyelid. The orbital prosthesis was sufficiently retained by hard and soft tissue undercuts without any complications. The patients using the prosthesis are quite satisfied with the cosmetic results and felt comfortable attending the social events.

  6. Multidisciplinary approach for in-deep assessment of joint prosthesis failure.

    Science.gov (United States)

    Tessarolo, F; Caola, I; Piccoli, F; Dorigotti, P; Demattè, E; Molinari, M; Malavolta, M; Barbareschi, M; Caciagli, P; Nollo, G

    2009-01-01

    In spite of advancement in biomaterials and biomechanics, in development of new osteo-integrative materials and coatings, and in macro- micro- component design, a non negligible fraction of the implanted prosthesis fails before the expected lifetime. A prospective observational clinical study has been conducted to define and apply a set of experimental techniques to in-deep assess the failure of joint prosthesis. Microbiological, histological and micro-structural techniques were implemented to specifically address phenomena occurring at the tissue-implant interface. Results obtained from 27 cases of prosthetic joint failure are discussed in terms of sensitivity and specificity. A procedural flow-chart is finally proposed for the assessment of joint prosthesis failure.

  7. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.

    Science.gov (United States)

    Alwaal, Amjad; Al-Sayyad, Ahmad J

    2017-01-01

    Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  8. Classification of breast tissue for protocols development in mammography exam;Classificacao dos tecidos mamarios para elaboracao de protocolos em exames de mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, M. Ines; Caldas, Linda V.E. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Chohfi, Adriana C.S.; Figueiredo, Zenaide A. [Universidade Nove de Julho (UNINOVE), Sao Paulo, SP (Brazil). Dept. da Saude. Radiologia Medica

    2009-07-01

    For accomplishment of a mammogram should be considered several factors such as equipment used and the classification of breast cancer patients. The density of the breast is different of patient to patient, thus making it difficult many precocious diagnostic of breast cancer. There is a significant variation in the breast to be radiographed, depending on several factors presented in the breast tissue of breast prosthesis with or without breasts or with implants. This work had as objective main to make a survey of the factors that influence in the classification of mammary fabrics. With this survey and classification it can be better adjusted the protocols which will be more efficient in the mammography exam, preventing excess of radiation dose, stress for the patient, economy of raw material, control of the quality and rapidity in the process of image attainment. (author)

  9. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique

    Directory of Open Access Journals (Sweden)

    Issam Saliba

    2018-01-01

    Full Text Available Objective: To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S and a new fat interposition total ossicular replacement prosthesis (TORP-F in pediatric and adult patients and to assess the complication and the undesirable outcome. Study design: This is a retrospective study. Methods: This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes’ head as a partial ossicular replacement prosthesis. Results: The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52 compared with 40% in the TORP-S group (n = 29. However, the adult cohort shows 79.3% in the TORP-F group (n = 52 compared with 43.75% in the TORP-S group (n = 25. These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03. Conclusions: The interposition of a fat graft between the legs of the titanium implants (TORP-F provides superior hearing results compared with a standard procedure (TORP-S in pediatric and adult populations because of its better stability in the oval window niche.

  10. Total Ossicular Replacement Prosthesis: A New Fat Interposition Technique.

    Science.gov (United States)

    Saliba, Issam; Sabbah, Valérie; Poirier, Jackie Bibeau

    2018-01-01

    To compare audiometric results between the standard total ossicular replacement prosthesis (TORP-S) and a new fat interposition total ossicular replacement prosthesis (TORP-F) in pediatric and adult patients and to assess the complication and the undesirable outcome. This is a retrospective study. This study included 104 patients who had undergone titanium implants with TORP-F and 54 patients who had undergone the procedure with TORP-S between 2008 and 2013 in our tertiary care centers. The new technique consists of interposing a fat graft between the 4 legs of the universal titanium prosthesis (Medtronic Xomed Inc, Jacksonville, FL, USA) to provide a more stable TORP in the ovale window niche. Normally, this prosthesis is designed to fit on the stapes' head as a partial ossicular replacement prosthesis. The postoperative air-bone gap less than 25 dB for the combined cohort was 69.2% and 41.7% for the TORP-F and the TORP-S groups, respectively. The mean follow-up was 17 months postoperatively. By stratifying data, the pediatric cohort shows 56.5% in the TORP-F group (n = 52) compared with 40% in the TORP-S group (n = 29). However, the adult cohort shows 79.3% in the TORP-F group (n = 52) compared with 43.75% in the TORP-S group (n = 25). These improvements in hearing were statistically significant. There were no statistically significant differences in the speech discrimination scores. The only undesirable outcome that was statistically different between the 2 groups was the prosthesis displacement: 7% in the TORP-F group compared with 19% in the TORP-S group ( P  = .03). The interposition of a fat graft between the legs of the titanium implants (TORP-F) provides superior hearing results compared with a standard procedure (TORP-S) in pediatric and adult populations because of its better stability in the oval window niche.

  11. Breast Reconstruction Following Cancer Treatment.

    Science.gov (United States)

    Gerber, Bernd; Marx, Mario; Untch, Michael; Faridi, Andree

    2015-08-31

    About 8000 breast reconstructions after mastectomy are per - formed in Germany each year. It has become more difficult to advise patients because of the wide variety of heterologous and autologous techniques that are now available and because of changes in the recommendations about radiotherapy. This article is based on a review of pertinent articles (2005-2014) that were retrieved by a selective search employing the search terms "mastectomy" and "breast reconstruction." The goal of reconstruction is to achieve an oncologically safe and aestically satisfactory result for the patient over the long term. Heterologous, i.e., implant-based, breast reconstruction (IBR) and autologous breast reconstruction (ABR) are complementary techniques. Immediate reconstruction preserves the skin of the breast and its natural form and prevents the psychological trauma associated with mastectomy. If post-mastectomy radiotherapy (PMRT) is not indicated, implant-based reconstruction with or without a net/acellular dermal matrix (ADM) is a common option. Complications such as seroma formation, infection, and explantation are significantly more common when an ADM is used (15.3% vs. 5.4% ). If PMRT is performed, then the complication rate of implant-based breast reconstruction is 1 to 48% ; in particular, Baker grade III/IV capsular fibrosis occurs in 7 to 22% of patients, and the prosthesis must be explanted in 9 to 41% . Primary or, preferably, secondary autologous reconstruction is an alternative. The results of ABR are more stable over the long term, but the operation is markedly more complex. Autologous breast reconstruction after PMRT does not increase the risk of serious complications (20.5% vs. 17.9% without radiotherapy). No randomized controlled trials have yet been conducted to compare the reconstructive techniques with each other. If radiotherapy will not be performed, immediate reconstruction with an implant is recommended. On the other hand, if post-mastectomy radiotherapy

  12. Fabrication of a 3D Printing Definitive Obturator Prosthesis: a Clinical Report

    Directory of Open Access Journals (Sweden)

    Georgios Kouveliotis

    2017-01-01

    Full Text Available Introduction: Digital technologies related to imaging and manufacturing provide the clinician with a wide variety of treatment options. Stereolithography (SLA offers a simple and predictable way for an accurate reconstruction of congenital or acquired defects. Clinical case: A 65-years old cancer patient with non- keratinized squamous cell carcinoma of left maxillary sinus came for a prosthetic clinical evaluation. A bilateral maxillectomy was performed and the treatment plan included definite obturator prosthesis for the upper arch. CT data and 3D planning software were used to create a 3D printing plastic model of the defect. A wax pattern of the hollow bulb was fabricated and cured with heatcured silicone soft liner. A final impression was obtained with the hollow bulb placed intraorally. The master cast was duplicated and the new cast was invested and reflasked. The flasks were opened, wax was boiled out and some space was created in the internal part of the obturator. Transparent heat cured acrylic resin was sandwiched with, at the inner part of the bulb, improving the retention between the acrylic denture base and the silicone based soft lining material. The patient was then placed on a 6-month recall. The five-year follow up consists of a chair side relining, when needed, of the definite removable prostheses. Conclusion: Maxillofacial surgery patients may develop postoperative complications such as trismus and pain. In these cases, the combination of digital technology and conventional techniques provide an accurate prosthetic restoration.

  13. Technical Considerations in Rehabilitation of an Edentulous Total Glossectomy Patient

    Directory of Open Access Journals (Sweden)

    Pravin Bhirangi

    2012-01-01

    Full Text Available The technician by virtue of his profession plays an important role in fabricating silicone tongue prosthesis for a total glossectomy patient. The technician, with his skills and specialized knowledge in handling material, plays a valuable role as a member of the oncology team. A patient with total glossectomy can be rehabilitated by silicone tongue prosthesis as an aid to improve his speech and swallowing. This paper describes the technical steps involved in fabricating a silicone tongue prosthesis for an edentulous total glossectomy patient.

  14. Percutaneous Revision of a Testicular Prosthesis is Safe, Cost-effective, and Provides Good Patient Satisfaction

    Directory of Open Access Journals (Sweden)

    Eugene B. Cone

    2015-09-01

    Full Text Available Office-based percutaneous revision of a testicular prosthesis has never been reported. A patient received a testicular prosthesis but was dissatisfied with the firmness of the implant. In an office setting, the prosthesis was inflated with additional fluid via a percutaneous approach. Evaluated outcomes included patient satisfaction, prosthesis size, recovery time, and cost savings. The patient was satisfied, with no infection, leak, or complication after more than 1 year of follow-up, at significantly less cost than revision surgery. Percutaneous adjustment of testicular prosthesis fill-volume can be safe, inexpensive, and result in good patient satisfaction.

  15. A direct bonded fixed partial dental prosthesis: A clinical report

    OpenAIRE

    Tanoue, Naomi; Tanaka, Takuo

    2015-01-01

    A direct bonded fixed partial dental prosthesis, with a composite resin denture tooth as a pontic, a tri-n-butylborane initiated adhesive resin, and screw posts for reinforcement, was still functioning after an observation period of 20 years. The prosthesis was found to be reliable for long-term clinical use when chemically and mechanically reinforced.

  16. Dose distribution perturbation due to a Co-Cr-Mo prosthesis

    International Nuclear Information System (INIS)

    Castro Novais, J.; Rodriguez Rodriguez, C.; Cabello Murillo, E.; Fernandez Leton, P.; Perez Moreno, J. M.; Lopez Fernandez, A.; Ferrando Sanchez, A.; Martinez Gomez, L. C.

    2009-01-01

    Knowledge of the attenuation and interface effects when irradiating metallic prosthesis is necessary for the radiotherapy treatment of patients with this kind of implants. This report studies the dose distribution of a 6 MV photon beam in the vicinity of a 1,5 cm diameter Co-Cr-Mo prosthesis. Measurements with Gafchromic EBT radiochromic films have been made. Two blocks of cut films have been placed next to the prosthesis, one in each side. Forty two films reaching a height of 1 cm have been piled up in each block. A spatial resolution equal to the thickness of one film (0,24 mm) is achieved. The results show 28% attenuation and the production of a 42% overdose at the entrance interface, 12% and 3% at 1 mm and 2 mm away from the prosthesis respectively. A 5 mm build-up region is originated in the exit interface, where the under dose is less than 10%. The knowledge of the transmission factor and the interface effects allows us to assess the dose calculated by the treatment planning system. (Author) 11 refs.

  17. Referral of sensation to an advanced humanoid robotic hand prosthesis.

    Science.gov (United States)

    Rosén, Birgitta; Ehrsson, H Henrik; Antfolk, Christian; Cipriani, Christian; Sebelius, Fredrik; Lundborg, Göran

    2009-01-01

    Hand prostheses that are currently available on the market are used by amputees to only a limited extent, partly because of lack of sensory feedback from the artificial hand. We report a pilot study that showed how amputees can experience a robot-like advanced hand prosthesis as part of their own body. We induced a perceptual illusion by which touch applied to the stump of the arm was experienced from the artificial hand. This illusion was elicited by applying synchronous tactile stimulation to the hidden amputation stump and the robotic hand prosthesis in full view. In five people who had had upper limb amputations this stimulation caused referral touch sensation from the stump to the artificial hand, and the prosthesis was experienced more like a real hand. We also showed that this illusion can work when the amputee controls the movements of the artificial hand by recordings of the arm muscle activity with electromyograms. These observations indicate that the previously described "rubber hand illusion" is also valid for an advanced hand prosthesis, even when it has a robotic-like appearance.

  18. Quantifying shape changes of silicone breast implants in a murine model using in vivo micro-CT.

    Science.gov (United States)

    Anderson, Emily E; Perilli, Egon; Carati, Colin J; Reynolds, Karen J

    2017-08-01

    A major complication of silicone breast implants is the formation of a capsule around the implant known as capsular contracture which results in the distortion of the implant. Recently, a mouse model for studying capsular contracture was examined using micro-computed tomography (micro-CT), however, only qualitative changes were reported. The aim of this study was to develop a quantitative method for comparing the shape changes of silicone implants using in vivo micro-CT. Mice were bilaterally implanted with silicone implants and underwent ionizing radiation to induce capsular contracture. On day 28 post-surgery mice were examined in vivo using micro-CT. The reconstructed cross-section images were visually inspected to identify distortion. Measurements were taken in 2D and 3D to quantify the shape of the implants in the normal (n = 11) and distorted (n = 5) groups. The degree of anisotropy was significantly higher in the distorted implants in the transaxial view (0.99 vs. 1.19, p = 0.002) and the y-axis lengths were significantly shorter in the sagittal (9.27 mm vs. 8.55 mm, p = 0.015) and coronal (9.24 mm vs. 8.76 mm, p = 0.031) views, indicating a deviation from the circular cross-section and shortening of the long axis. The 3D analysis revealed a significantly lower average thickness (sphere-fitting method) in distorted implants (6.86 mm vs. 5.49 mm, p = 0.002), whereas the volume and surface area did not show significant changes. Statistically significant differences between normal and distorted implants were found in 2D and 3D using distance measurements performed via micro-CT. This objective analysis method can be useful for a range of studies involving deformable implants using in vivo micro-CT. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1447-1452, 2017. © 2016 Wiley Periodicals, Inc.

  19. Comparison of the Explantation Rate of Poly Implant Prothèse, Allergan, and Pérouse Silicone Breast Implants within the First Four Years after Reconstructive Surgery before the Poly Implant Prothèse Alert by the French Regulatory Authority.

    Science.gov (United States)

    Leduey, Alexandre; Mazouni, Chafika; Leymarie, Nicolas; Alkhashnam, Heba; Sarfati, Benjamin; Garbay, Jean-Rémi; Gaudin, Amélie; Kolb, Frédéric; Rimareix, Françoise

    2015-01-01

    Background. In March 2010, ANSM (Agence Nationale de Sécurité du Medicament), the French Medical Regulatory Authority, withdrew Poly Implant Prothèse (PIP) breast implants from the market due to the use of non-medical-grade silicone gel. The aim of this study was to compare the removal rate (and reasons thereof) of breast implants produced by different manufacturers before the ANSM alert. Materials and Methods. From October 2006 to January 2010, 652 women received 944 implants after breast cancer surgery at the Gustave Roussy Comprehensive Cancer Center, Paris (France). The complications and removal rates of the different implant brands used (PIP, Allergan, and Pérouse) were evaluated and compared. Results. PIP implants represented 50.6% of the used implants, Allergan 33.4%, and Pérouse 16%. The main reasons for implant removal were patient dissatisfaction due to aesthetic problems (43.2%), infection (22.2%), and capsular contracture (13.6%). Two years after implantation, 82% of Pérouse implants, 79% of PIP, and 79% of Allergan were still in situ. There was no difference in removal rate among implant brands. Conclusion. Before the ANSM alert concerning the higher rupture rate of PIP breast implants, our implant removal rate did not predict PIP implant failure related to the use of nonapproved silicone gel.

  20. Adhesive strength of hydroxyl apatite(HA coating and biomechanics behavior of HA-coated prosthesis:an experimental study

    Directory of Open Access Journals (Sweden)

    Tian-yang ZHANG

    2011-05-01

    Full Text Available Objective To explore the influence of adhesive strength of hydroxyapatite(HA coating on the post-implantation stability of HA-coated prosthesis.Methods The adhesive strength and biomechanics behavior of HA coating were studied by histopathological observation,material parameters and biomechanical testing,the titanium(Ti-coated prosthesis was employed as control.Results Scratch test showed that the adhesive strength of HA coating was significantly lower than that of Ti coating(P < 0.01.Histopathological examination and bone morphometry showed that,at the early stage of prosthesis implantation,the bony growth around HA-coated prosthesis was significantly higher than that around Ti-coated prosthesis(P < 0.01,but the ultimate shear strength of HA-coated prosthesis was much lower than that of Ti-coated prosthesis(P < 0.01.After the push-out test with prosthesis,histopathological observation showed that there were accumulations of clump-and strip-like granular residues on the surface of bones that newly grew around the HA-coated prosthesis,and surface energy-dispersive X-ray spectroscopy(EDX analysis also confirmed that the shear stress induced HA decohesion from the substrate of prosthesis.Conclusions Although HA coating showed a satisfactory effect on early bone formation and prosthetic stability,due to the deficiencies of adhesive strength,the early stability of prosthesis may be gradually destroyed by the shear loads of human body and coating degradation.

  1. The method of manufacture of nylon dental partially removable prosthesis using additive technologies

    Science.gov (United States)

    Kashapov, R. N.; Korobkina, A. I.; Platonov, E. V.; Saleeva, G. T.

    2014-12-01

    The article is devoted to the topic of creating new methods of dental prosthesis. The aim of this work is to investigate the possibility of using additive technology to create nylon prosthesis. As a result of experimental studies, was made a sample of nylon partially removable prosthesis using 3D printing has allowed to simplify, accelerate and reduce the coat of manufacturing high-precision nylon dentures.

  2. 21 CFR 874.3540 - Prosthesis modification instrument for ossicular replacement surgery.

    Science.gov (United States)

    2010-04-01

    ... replacement surgery. 874.3540 Section 874.3540 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... § 874.3540 Prosthesis modification instrument for ossicular replacement surgery. (a) Identification. A prosthesis modification instrument for ossicular replacement surgery is a device intended for use by a...

  3. Predictors of Receiving a Prosthesis for Adults With Above-Knee Amputations in a Well-Defined Population.

    Science.gov (United States)

    Mundell, Benjamin F; Kremers, Hilal Maradit; Visscher, Sue; Hoppe, Kurtis M; Kaufman, Kenton R

    2016-08-01

    Prior studies have identified age as a factor in determining an individual's likelihood of receiving a prosthesis following a lower limb amputation. These studies are limited to specific subsets of the general population and are unable to account for preamputation characteristics within their study populations. Our study seeks to determine the effect of preamputation characteristics on the probability of receiving a prosthesis for the general population in the United States. To identify preamputation characteristics that predict of the likelihood of receiving a prosthesis following an above-knee amputation. A retrospective, population-based cohort study. Olmsted County, Minnesota (2010 population: 144,248). Individuals (n = 93) over the age of 18 years who underwent an above-knee amputation, that is, knee disarticulation or transfemoral amputation, while residing in Olmsted County, MN, between 1987 and 2013. Characteristics affecting the receipt of a prosthesis were analyzed using a logistic regression and a random forest algorithm for classification trees. Preamputation characteristics included age, gender, amputation etiology, year of amputation, mobility, cognitive ability, comorbidities, and time between surgery and the prosthesis decision. The association of preamputation characteristics with the receipt of a prosthesis following an above-knee amputation. Twenty-four of the participants received a prosthesis. The odds of receiving a prosthesis were almost 30 times higher in those able to walk independently prior to an amputation relative to those who could not walk independently. A 10-year increase in age was associated with a 53.8% decrease in the likelihood of being fit for a prosthesis (odds ratio = 0.462, P =.030). Time elapsed between surgery and the prosthesis decision was associated with a rise in probability of receiving a prosthesis for the first 3 months in the random forest algorithm. No other observed characteristics were associated with receipt

  4. A wide-field suprachoroidal retinal prosthesis is stable and well tolerated following chronic implantation.

    Science.gov (United States)

    Villalobos, Joel; Nayagam, David A X; Allen, Penelope J; McKelvie, Penelope; Luu, Chi D; Ayton, Lauren N; Freemantle, Alexia L; McPhedran, Michelle; Basa, Meri; McGowan, Ceara C; Shepherd, Robert K; Williams, Chris E

    2013-05-01

    The safety of chronic implantation of a retinal prosthesis in the suprachoroidal space has not been established. This study aimed to determine the safety of a wide-field suprachoroidal electrode array following chronic implantation using histopathologic techniques and electroretinography. A platinum electrode array in a wide silicone substrate was implanted unilaterally in the suprachoroidal space in adult cats (n = 7). The lead and connector were tunneled out of the orbit and positioned subcutaneously. Postsurgical recovery was assessed using fundus photography and electroretinography (ERG). Following 3 months of passive implantation, the animals were terminated and the eyes assessed for the pathologic response to implantation. The implant was mechanically stable in the suprachoroidal space during the course of the study. The implanted eye showed a transient increase in ERG response amplitude at 2 weeks, which returned to normal by 3 months. Pigmentary changes were observed at the distal end of the implant, near the optic disc. Histopathologic assessment revealed a largely intact retina and a thin fibrous capsule around the suprachoroidal implant cavity. The foreign body response was minimal, with sporadic presence of macrophages and no active inflammation. All implanted eyes were negative for bacterial or fungal infections. A midgrade granuloma and thick fibrous buildup surrounded the extraocular cable. Scleral closure was maintained in six of seven eyes. There were no staphylomas or choroidal incarceration. A wide-field retinal prosthesis was stable and well tolerated during long-term suprachoroidal implantation in a cat model. The surgical approach was reproducible and overall safe.

  5. Strategy to avoid patient-prosthesis mismatch: aortic root enlargement.

    Science.gov (United States)

    Srivastava, Dharmendra Kumar; Sanki, Prokash; Bhattacharya, Subhankar; Siddique, Javed Veqar

    2014-02-01

    The choice of a valve with an effective orifice area matching the body surface area and providing efficient hemodynamics is an important factor affecting mortality and morbidity in patients undergoing aortic valve replacement. Our preventative strategy was to implant a larger prosthetic valve by aortic root enlargement using the Nunez procedure in 17 patients between February 2010 and January 2011. The decision to enlarge the aortic root was taken when the 19-mm sizer could not be negotiated easily through the aortic root, or on the basis of body surface area of the patient or type of prosthesis available. Postoperative reductions in peak and mean pressure gradients across aortic valve of 12.8-16.5 and 10.2-12.6 mm Hg, respectively, were observed. Postoperative effective orifice areas of the aortic valves were 1.1-1.5 cm(2). By upsizing the aortic valve, we were able to eliminate patient-prosthesis mismatch in 5 patients, and reduce severe patient-prosthesis mismatch to moderate in 11. Aortic root enlargement is a safe procedure. Therefore, cardiac surgeons should not be reluctant to enlarge the aortic root with an autologous pericardial patch to permit implantation of an adequate size of aortic valve prosthesis, with minimal additional aortic crossclamp time and no added cost.

  6. Smart image processing system for retinal prosthesis.

    Science.gov (United States)

    Weiland, James D; Parikh, Neha; Pradeep, Vivek; Medioni, Gerard

    2012-01-01

    Retinal prostheses for the blind have demonstrated the ability to provide the sensation of light in otherwise blind individuals. However, visual task performance in these patients remains poor relative to someone with normal vision. Computer vision algorithms for navigation and object detection were evaluated for their ability to improve task performance. Blind subjects navigating a mobility course had fewer collisions when using a wearable camera system that guided them on a safe path. Subjects using a retinal prosthesis simulator could locate objects more quickly when an object detection algorithm assisted them. Computer vision algorithms can assist retinal prosthesis patients and low-vision patients in general.

  7. [Lessons from a heart valve prosthesis controversy].

    Science.gov (United States)

    Vandenbroucke, J P; Grobbee, D E

    1998-07-18

    Two lessons are to be learnt from the Björk-Shiley heart valve prosthesis tragedy. In the first place pharmacoepidemiologic studies are seriously hampered by recent privacy legislation. Individual patients carrying such a prosthesis cannot be traced and advised as to their health risks any more, because their legal autonomy has to be respected. This is clearly not to their advantage. In the second place the atmosphere of marketing and litigation and the increasing dependency of researchers on money from sources with conflicting interests is not conducive to a well-informed and balanced judgement of the epidemiological evidence of safety and efficacy of medical treatments.

  8. Combined nuclear and digital subtraction contrast arthrography in painful knee prosthesis

    International Nuclear Information System (INIS)

    Namasivayam, J.; Forrester, A.; Poon, F.W.; Cuthbert, G.F.; McKillop, J.H.; Bryan, A.S.

    1992-01-01

    The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear-arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography. (orig.)

  9. Candida albicans, Staphylococcus aureus and Streptococcus mutans colonization in patients wearing dental prosthesis.

    Science.gov (United States)

    Baena-Monroy, Tania; Moreno-Maldonado, Víctor; Franco-Martínez, Fernando; Aldape-Barrios, Beatriz; Quindós, Guillermo; Sánchez-Vargas, Luis Octavio

    2005-04-01

    Denture stomatitis is associated to Candida albicans, different bacteria and other co-factors such as an acid pH, a carbohydrate ingestion increase, different systemic illnesses and pharmacological treatments. The aim of this study was to determine Candida albicans, Staphylococcus aureus and Streptococcus mutans prevalence in the mucous membrane and prosthesis of patients with and without atrophic denture stomatitis and its relationship with other potential clinical co-factors. Saliva was collected from 105 patients (62 female and 43 male) wearing dental prosthesis in order to measure their pH. Oral samples of the mucous membrane and the internal surface of dental prosthesis were taken with sterile cotton to proceed with the microbiological study. The identification of the isolated microorganisms was performed using conventional microbiological methods. Diabetes and Hypertension were the most frequent systemic illnesses. High carbohydrate ingestion was observed in numerous patients. Atrophic denture stomatitis was reported in 50 patients and the pH average in saliva was of 5.2. The presence of C albicans, S. aureus and S. mutans in the mucous membrane and prosthesis was of 51.4%, 52.4% and 67.6%, respectively. C. albicans was isolated in 66.7% from the prosthesis, whereas S. aureus and S. mutans were isolated in 49.5% of those same prosthesis. C. albicans was isolated in 86% of the patients with atrophic denture stomatitis and S. aureus was isolated in a similar percentage (84% of patients). The isolation of S. mutans was less frequent, and it was observed in 16% of the oral samples of these patients. C. albicans, S. aureus and S. mutans frequently colonize the oral mucous of patients wearing dental prosthesis. This illness-bearing condition is more frequent in patients with denture stomatitis, even though dental prosthesis colonization is lower than in the oral mucous.

  10. Survival of various implant-supported prosthesis designs following 36 months of clinical function.

    Science.gov (United States)

    Rodriguez, A M; Orenstein, I H; Morris, H F; Ochi, S

    2000-12-01

    The use of endosseous dental implants to replace natural teeth lost to trauma, dental caries, or periodontal disease has become a predictable form of prosthetic treatment since gaining popularity in the early 1980s. While numerous clinical studies have focused on the survival of implants, few address the survival of different prosthesis designs. Beginning in 1991, 882 prostheses supported by more than 2,900 implants (687 patients) were placed by the Department of Veterans Affairs Dental Implant Clinical Research Group (DICRG). These prostheses were divided into five research strata based on arch location. The recommended design for each stratum was: bar-supported overdenture (maxillary completely edentulous); screw-retained hybrid denture (mandibular completely edentulous); screw-retained fixed partial denture (mandibular and maxillary posterior partially edentulous); and cemented single crown (maxillary anterior single tooth). Alternative overdenture designs were utilized in the edentulous arches when the recommended prosthesis could not be fabricated. Prosthesis success rates for the research strata were calculated for an observation time of up to 36 months following prosthesis placement. Success rates for the maxillary edentulous stratum ranged from 94.6% for the bar-retained overdenture supported by five to six fixtures to 81.8% for the cap-retained overdenture. The mandibular edentulous strata produced success rates of 98.1% for the fixed hybrid prosthesis to 91.7% for the cap-retained prosthesis. Success rates for maxillary and mandibular posterior fixed partial dentures were 94.3% and 92.6%, respectively, while the maxillary anterior single-tooth prosthesis yielded a success rate of 98.1% for the 36-month observation period. The recommended prosthesis designs investigated in this study proved to be reliable, with encouraging success rates for an observation period of 36 months following placement.

  11. Retrospective Study on External Canine Limb Prosthesis used in 24 patients

    Directory of Open Access Journals (Sweden)

    Brittany Jean Carr

    2018-03-01

    Full Text Available Objective: The purpose of this retrospective study is to provide data regarding external prosthetic use in small animal patients, evaluate the common complications associated with external prosthetics, and evaluate the outcome of patients using an external prosthetic.Background: The use of external canine limb prosthetics is relatively uncommon in veterinary medicine today.  However, there is growing interest in prosthetics and their clinical application because these devices may offer an alternative to euthanasia in severe cases where full amputation or alternative methods of limb spare are not an option. The goal of the prosthesis is to provide a better quality of life, help prevent further deformation and degeneration of existing joints, decrease leg length discrepancies, increase exercise and activity levels, provide a means to participate in rehabilitation therapy and maintain the ability to perform daily acts of living. To the author’s knowledge, there is no report of external prosthetic use in small animal veterinary medicine, providing the profession with baseline information for use in, not only general practice or referral practice, but also future research.Evidentiary value: This retrospective study provides data regarding external prosthetic use in small animal patients, evaluates the procedures, manufacturing, rehabilitation and common complications associated with external prosthetics, and evaluates the factors that determine a patient’s prosthetic candidacy.Methods: Patients that had an external prosthesis custom manufactured for them at Animal Orthocare, LLC and had a complete medical record were identified for this study.  A client survey was completed via e-mail or telephone to collect further data about the patients, including age, weight, breed, sex, affected limb(s, reason for prosthesis, level of amputation, activities patient could perform with prosthesis in place, prosthetic fit, prosthetic migration (e

  12. Research, design and development project Myoelectric Prosthesis of Upper Limb

    International Nuclear Information System (INIS)

    Galiano, L; Montaner, E; Flecha, A

    2007-01-01

    A Research Design and Development Project was developed of a myoelectric prosthesis for a pediatric patient presenting congenital amputation of the left forearm below the elbow. A multidisciplinary work-team was formed for this goal, in order to solve the several (/various) aspects regarding this project (mechanical, ergonomics, electronics, physical). The prosthesis as an electromechanical device was divided in several blocks, trying to achieve a focused development for each stage, acording to requisites. A mechanical prototype of the prothesis was designed and built along with the circuitry needed for EMG aquisition, control logic and drivers. Having acomplished the previuos stages, the project is now dealing with the definitions of the interface between the prosthesis and the patient, with promising perspectives

  13. Research, design and development project Myoelectric Prosthesis of Upper Limb

    Energy Technology Data Exchange (ETDEWEB)

    Galiano, L; Montaner, E; Flecha, A [Bioparx, J Hernandez 1101, Parana, ERios (Argentina)

    2007-11-15

    A Research Design and Development Project was developed of a myoelectric prosthesis for a pediatric patient presenting congenital amputation of the left forearm below the elbow. A multidisciplinary work-team was formed for this goal, in order to solve the several (/various) aspects regarding this project (mechanical, ergonomics, electronics, physical). The prosthesis as an electromechanical device was divided in several blocks, trying to achieve a focused development for each stage, acording to requisites. A mechanical prototype of the prothesis was designed and built along with the circuitry needed for EMG aquisition, control logic and drivers. Having acomplished the previuos stages, the project is now dealing with the definitions of the interface between the prosthesis and the patient, with promising perspectives.

  14. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  15. Prosthesis-patient mismatch due to small ring annuloplasty in patients with degenerative mitral insufficiency.

    Science.gov (United States)

    Kawamoto, Naonori; Fujita, Tomoyuki; Hata, Hiroki; Shimahara, Yusuke; Sato, Shunsuke; Kobayashi, Junjiro

    2016-08-01

    Avoidance of prosthesis-patient mismatch (PPM) is important when selecting a mitral valve prosthesis. This study investigated the effect of PPM after small ring mitral valve annuloplasty on postoperative hemodynamics and the clinical course. This study retrospectively reviewed 227 patients with symptomatic severe mitral insufficiency (MI) who underwent mitral valve repair for degenerative MI using an Edwards ring or band (size: 26-32mm) between 2003 and 2012. Echocardiography was performed postoperatively and at follow-up to evaluate cardiac function, including residual MI, mean transmitral pressure gradient, left atrial diameter (LAD), and tricuspid regurgitant pressure gradient (TRPG). There were no operative deaths. Actuarial freedom from major adverse cardiac events was 91% at 10 years. The postoperative MI grade was not significantly different between different sizes of prosthesis (26mm, 0.67±0.8; 28mm, 0.73±0.9; 30mm, 0.85±0.9; 32mm, 0.3±0.6). LAD and TRPG were significantly lower for each size of prosthesis at follow-up (all pbody surface area received a significantly smaller prosthesis (pprosthesis than in patients with a larger size of prosthesis. Thirty-three patients had a follow-up transmitral pressure gradient ≥5mmHg. The follow-up LAD was larger in patients with a transmitral pressure gradient prosthesis. However, use of a smaller prosthesis may result in a higher mean transmitral pressure gradient, and may inhibit reverse remodeling of the left atrium. Therefore, PPM should be avoided. Copyright © 2015 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  16. Definitive diagnosis of breast implant rupture using magnetic resonance imaging.

    Science.gov (United States)

    Ahn, C Y; Shaw, W W; Narayanan, K; Gorczyca, D P; Sinha, S; Debruhl, N D; Bassett, L W

    1993-09-01

    Breast implant rupture is an important complication of augmented and reconstructed breasts. Although several techniques such as mammography, xeromammography, ultrasound, thermography, and computed tomographic (CT) scanning have been proven to be useful to detect implant rupture, they have several disadvantages and lack specificity. In the current study, we have established magnetic resonance imaging (MRI) as a definitive, reliable, and reproducible technique to diagnose both intracapsular and extracapsular ruptures. The study was conducted in 100 symptomatic patients. Our imaging parameters were able to identify ruptures in implants with silicone shells. All the ruptures showed the presence of wavy lines, free-floating silicone shell within the gel ("free-floating loose-thread sign" or "linguine sign"). We had a 3.75 percent incidence of false-positive and false-negative results. The sensitivity for detection of silicone implant rupture was 76 percent, with a specificity of 97 percent. In addition, we also were able to identify the artifacts that may interfere with the definitive diagnosis of implant rupture.

  17. Evaluation of possible hip prosthesis infection with In-111 leukocyte scintigraphy

    International Nuclear Information System (INIS)

    Noto, R.B.; Alavi, A.; Star, A.M.; Cuckler, J.M.; Eisenberg, B.

    1987-01-01

    To evaluate the utility of In-111 leukocyte scintigraphy in patients with possible hip prosthesis infection, the authors retrospectively reviewed 44 such scans without clinical history. The results of In-111 leukocyte scans were compared with intraoperative cultures obtained at the time of prosthesis revision in 34 patients, with hip aspirates and/or clinical follow-up obtained in the remaining ten patients. This comparison yielded a 71% sensitivity, 78% specificity, and 77% overall accuracy. They conclude that In-111 leukocyte scans can be helpful in the evaluation of suspected hip prosthesis infection, but they are not as accurate as has been previously reported elsewhere

  18. A Structural Analysis of a Mechanical Heart Valve Prosthesis with Flat Leaflet

    Science.gov (United States)

    Kwon, Young Joo

    This paper addresses the basic concept of MDO methodology and the structural analysis that should be performed in the design process of a mechanical heart valve prosthesis with flat leaflet using MDO methodology. In the structural design of the mechanical heart valve (MHV) prosthesis, the fluid mechanics analysis is executed for the blood flow passing through the leaflets of a mechanical heart valve prosthesis. Thereafter, the rigid body dynamics analysis of the leaflet motion is performed to obtain the structural condition for the structural mechanics analysis of the deformed leaflet. Then the structural mechanics analysis of the deformed leaflet follows to confirm the minimum thickness of the leaflet for the structural durability of the mechanical heart valve prosthesis. This paper shows that the minimum leaflet thickness can be evaluated to be 0.6mm among the suggested thicknesses.

  19. Magnetic resonance imaging of breast. Actual technique and indications

    International Nuclear Information System (INIS)

    Tardivon, Anne

    2007-01-01

    Optimal breast MRI protocols are required using dedicated breast coils, high spatial resolution dynamic sequences (morphologic criteria are significantly more accurate than kinetic criteria) and bolus injection of contrast medium. Any abnormal MR enhancement must be described using BI-RADSMRI lexicon. Main indications of breast MRI are: suspicion of intra-capsular rupture (silicone implants), local relapse in a treated breast, search for breast cancer (metastatic axillary lymph nodes), locals staging of a breast cancer (dense breasts), follow-up of cancer under neoadjuvant chemotherapy, and screening in high-risk patients (gene mutation background). MRI is also useful for patients with unresolved problems at standard imaging (high negative predictive value of MRI). In patients with breast cancer, it is important to underline the need for radiologists to work with the multidisciplinary team and the ability to perform MR-guided biopsies for additional suspicious enhancements. (author) [es

  20. PIP breast implants: rupture rate and correlation with breast cancer.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Cornacchia, I; Vincenti, L; Ranieri, V; Cirili, A; Rella, L; Stabile Ianora, A A; Angelelli, G

    2014-01-01

    To evaluate the incidence of Poly Implant Prosthése (PIP) rupture as assessed by magnetic resonance imaging (MRI), the prevalence of the detected signs and the potential correlation with breast carcinoma. 67 patients with silicone breast implants and clinical indications for breast MRI were evaluated for a total of 125 implants: 40 (32%) PIP in 21 patients and 85 non-PIP in 46 patients (68%), the latest considered as control group. A 1.5-T MR imaging device was used in order to assess implant integrity with dedicated sequences and in 6 cases a dynamic study was performed for characterizing breast lesions. Two radiologists with more than 5 years' experience in the field of MRI evaluated in consensus all MR images searching for the presence of clear signs of intra or extra-capsular implant rupture. 20/40 (50%) PIP implants presented signs of intra-capsular rupture: linguine sign in 20 cases (100%), tear-drop sign in 6 (30%). In 12/20 cases (60%), MRI signs of extra-capsular rupture were detected. In the control group, an intra-capsular rupture was diagnosed in 12/85 cases (14%) associated with extra-capsular one in 5/12 cases (42%). Among the six cases with suspected breast lesions, in 2/21 patients with PIP implants (10%) a breast carcinoma was diagnosed (mucinous carcinoma, n=1; invasive ductal carcinoma, n=1). In 4/46 patients (9%) with non-PIP implants, an invasive ductal carcinoma was diagnosed. The rupture rate of PIP breast implants is significantly higher than non-PIP (50% vs 14%). MRI represents the most accurate imaging tool for evaluating breast prostheses and the linguine sign is the most common MRI sign to be searched. The incidence of breast carcinoma does not significantly differ between the PIP and non-PIP implants and a direct correlation with breast cancer can not been demonstrated.

  1. Quantifying risk of penile prosthesis infection with elevated glycosylated hemoglobin.

    Science.gov (United States)

    Wilson, S K; Carson, C C; Cleves, M A; Delk, J R

    1998-05-01

    Elevation of glycosylated hemoglobin above levels of 11.5 mg.% has been considered a contraindication to penile prosthesis implantation in diabetic patients. We determine the predictive value of glycosylated hemoglobin A1C in penile prosthesis infections in diabetic and nondiabetic patients to confirm or deny this prevalent opinion. We conducted a 2-year prospective study of 389 patients, including 114 diabetics, who underwent 3-piece penile prosthesis implantation. All patients had similar preoperative preparation without regard to diabetic status, control or glycosylated hemoglobin A1C level. Risk of infection was statistically analyzed for diabetics versus nondiabetics, glycosylated hemoglobin A1C values above and below 11.5 mg.%, insulin dependent versus oral medication diabetics, and fasting blood sugars above and below 180 mg.%. Prosthesis infections developed in 10 diabetics (8.7%) and 11 nondiabetics (4.0%). No increased infection rate was observed in diabetics with high fasting sugars or diabetics on insulin. There was no statistically significant increased infection risk with increased levels of glycosylated hemoglobin A1C among all patients or among only the diabetics. In fact, there was no meaningful difference in the median or mean level of glycosylated hemoglobin A1C in the infected and noninfected patients regardless of diabetes. Use of glycosylated hemoglobin A1C values to identify and exclude surgical candidates with increased risk of infections is not proved by this study. Elevation of fasting sugar or insulin dependence also does not increase risk of infection in diabetics undergoing prosthesis implantation.

  2. Wispy Prosthesis: A Novel Method in Denture Weight Reduction.

    Science.gov (United States)

    Anne, Gopinadh; Budeti, Sreedevi; Anche, Sampath Kumar; Zakkula, Srujana; Atla, Jyothi; Jyothula, Ravi Rakesh Dev; Appana, Krishna Chaitanya; Peddinti, Vijaya Kumar

    2016-04-01

    Stability and retention of the denture becomes at stake with the increase in weight of the denture prosthesis. As a consequence, different materials and methods have been introduced to overcome these issues but denture weight reduction still remains to be a cumbersome and strenuous procedure. To introduce a novel technique for the fabrication of denture prosthesis where in the weight of the denture will not affect the retention and stability of the denture. Four groups with a sample size of 10 each, were included where in one group was control and other three were study groups. The control group samples were made completely solid and the study group samples were packed with materials like bean balls, cellulose balls and polyacrylic fibers. The weight of all the samples of each study group was measured and compared with the control group. The observations were analyzed statistically by paired t-test. It was observed that the bean balls group produced a weight reduction of 31.3%, cellulose balls group 27.4% and polyacrylic fibers group 24.5% when compared to that of the control group. This novel technique will eliminate the problems that were associated in creating hollowness and at the same time will reduce the weight of the prosthesis and among all the study groups, bean balls group were found to reduce maximum weight of the prosthesis.

  3. Subway Mandibular Buccal Defect Blocked with Two Part Prosthesis Unified by Earth Magnets

    OpenAIRE

    Punjani, Shikha; Arora, Aman; Upadhyaya, Viram

    2012-01-01

    This clinical report describes the fabrication of a two-piece obturator used to close the mandibular buccal defect. Two-piece obturator prosthesis was fabricated with clear heat cure acrylic resin to be used during the healing period following the marsupialization of odontogenic keratocyst which had lead to the loss of portions of the mandibular buccal region. The prosthesis fabricated in two parts was joined by the rare earth magnets. Retention was increased by lining the prosthesis with tis...

  4. Aspiration of tracheoesophageal prosthesis in a laryngectomized patient

    Directory of Open Access Journals (Sweden)

    Conte Sergio C

    2012-08-01

    Full Text Available Abstract Background The voice prosthesis inserted into a tracheoesophageal fistula has become the most widely used device for voice rehabilitation in patients with total laryngectomy. Case presentation We describe a case of tracheoesophageal prosthesis’ (TEP aspiration in a laryngectomized patient, with permanent tracheal stoma, that appeared during standard cleaning procedure, despite a programme of training for the safe management of patients with voice prosthesis. Conclusions The definitive diagnosis and treatment were performed by flexible bronchoscopy, that may be considered the procedure of choice in these cases, also on the basis of the literature.

  5. Tracheobronchial Foreign Body Aspiration: Dental Prosthesis

    Directory of Open Access Journals (Sweden)

    Ataman Köse

    2014-01-01

    Full Text Available It is important to extract foreign bodies for avoiding life-threatening complications. They can lead to death if they are not treated. Different signs and symptoms could occur according to the complete or partial airway obstruction. Foreign body aspiration is a rare incident in adults. The organic foreign materials such as foods are found to be aspirated more commonly and are usually settled in the right bronchial system. However, dental prosthesis and teeth aspirations are rare in literature. In our study, a 52-year-old male patient who had aspirated the front part of his lower dental prosthesis accidentally is presented and the foreign body is extracted by using rigid bronchoscopy. There are many causes of aspiration but dental prosthetic aspirations should be kept in mind during sleep. For this reason, dental apparatus must be taken out while asleep.

  6. Stress analysis of different prosthesis materials in implant-supported fixed dental prosthesis using 3D finite element method

    Directory of Open Access Journals (Sweden)

    Pedram Iranmanesh

    2014-01-01

    Full Text Available Introduction: In the present study, the finite element method (FEM was used to investigate the effects of prosthesis material types on stress distribution of the bone surrounding implants and to evaluate stress distribution in three-unit implant-supported fixed dental prosthesis (FDP. Materials and Methods: A three-dimensional (3D finite element FDP model of the maxillary second premolar to the second molar was designed. Three load conditions were statically applied on the functional cusps in horizontal (57.0 N, vertical (200.0 N, and oblique (400.0 N, θ = 120° directions. Four standard framework materials were evaluated: Polymethyl methacrylate (PMMA, base-metal, porcelain fused to metal, andporcelain. Results: The maximum of von Mises stress in the oblique direction was higher than the vertical and horizontal directions in all conditions. In the bone-crestal section, the maximum von Mises stress (53.78 MPa was observed in PMMA within oblique load. In FDPs, the maximum stress was generated at the connector region in all conditions. Conclusion: A noticeable difference was not observed in the bone stress distribution pattern with different prosthetic materials. Although, higher stress value could be seen in polymethyl methacrylate, all types of prosthesis yielded the same stress distribution pattern in FDP. More clinical studies are needed to evaluate the survival rate of these materials.

  7. Comparison of the Explantation Rate of Poly Implant Prothèse, Allergan, and Pérouse Silicone Breast Implants within the First Four Years after Reconstructive Surgery before the Poly Implant Prothèse Alert by the French Regulatory Authority

    Directory of Open Access Journals (Sweden)

    Alexandre Leduey

    2015-01-01

    Full Text Available Background. In March 2010, ANSM (Agence Nationale de Sécurité du Medicament, the French Medical Regulatory Authority, withdrew Poly Implant Prothèse (PIP breast implants from the market due to the use of non-medical-grade silicone gel. The aim of this study was to compare the removal rate (and reasons thereof of breast implants produced by different manufacturers before the ANSM alert. Materials and Methods. From October 2006 to January 2010, 652 women received 944 implants after breast cancer surgery at the Gustave Roussy Comprehensive Cancer Center, Paris (France. The complications and removal rates of the different implant brands used (PIP, Allergan, and Pérouse were evaluated and compared. Results. PIP implants represented 50.6% of the used implants, Allergan 33.4%, and Pérouse 16%. The main reasons for implant removal were patient dissatisfaction due to aesthetic problems (43.2%, infection (22.2%, and capsular contracture (13.6%. Two years after implantation, 82% of Pérouse implants, 79% of PIP, and 79% of Allergan were still in situ. There was no difference in removal rate among implant brands. Conclusion. Before the ANSM alert concerning the higher rupture rate of PIP breast implants, our implant removal rate did not predict PIP implant failure related to the use of nonapproved silicone gel.

  8. Adjuvant Maneuvers for Residual Curvature Correction During Penile Prosthesis Implantation in Men with Peyronie's Disease.

    Science.gov (United States)

    Berookhim, Boback M; Karpman, Edward; Carrion, Rafael

    2015-11-01

    The surgical treatment of comorbid erectile dysfunction and Peyronie's disease has long included the implantation of an inflatable penile prosthesis as well as a number of adjuvant maneuvers to address residual curvature after prosthesis placement. To review the various surgical options for addressing curvature after prosthesis placement, with specific attention paid to an original article by Wilson et al. reporting on modeling over a penile prosthesis for the management of Peyronie's disease. A literature review was performed analyzing articles reporting the management of penile curvature in patients undergoing implantation of an inflatable penile prosthesis. Reported improvement in Peyronie's deformity as well as the complication rate associated with the various surgical techniques described. Modeling is a well-established treatment modality among patients with Peyronie's disease undergoing penile prosthesis implantation. A variety of other adjuvant maneuvers to address residual curvature when modeling alone is insufficient has been presented in the literature. Over 20 years of experience with modeling over a penile prosthesis have proven the efficacy and safety of this treatment option, providing the surgeon a simple initial step for the management of residual curvature after penile implantation which allows for the use of additional adjuvant maneuvers in those with significant deformities. © 2015 International Society for Sexual Medicine.

  9. Insidious strut fractures in a DeBakey-Surgitool aortic valve prosthesis.

    Science.gov (United States)

    Scott, S M; Sethi, G K; Paulson, D M; Takaro, T

    1978-04-01

    Recent reports of cage wear occurring in DeBakey-Surgitool aortic valve prostheses prompted us to examine with image intensification all our patients who have had this type of prosthesis implanted. One patient, who was asymptomatic, was discovered to have a prosthesis with two fractured struts. This patient's prosthetic valve was replaced successfully with a stented porcine heterograft prosthesis. Including the valve removed from this patient, 8 DeBakey-Surgitool aortic valves with structural defects have been reported to the manufacturer. In the absence of a catastrophic event, patients with valves having fractured or worn struts may be totally asymptomatic, and routine periodic roentgenographic examination may be the only way of detecting strut wear or fracture.

  10. A Biomechanical Model for the Development of Myoelectric Hand Prosthesis Control Systems

    NARCIS (Netherlands)

    Peerdeman, B.; van Baal, D.W.; Boere, Daphne; Kallenberg, L.A.C.; Stramigioli, Stefano; Misra, Sarthak

    2010-01-01

    Advanced myoelectric hand prostheses aim to reproduce as much of the human hand's functionality as possible. Development of the control system of such a prosthesis is strongly connected to its mechanical design; the control system requires accurate information on the prosthesis' structure and the

  11. Distant Migration of Multiple Siliconomas in Lower Extremities following Breast Implant Rupture: Case Report

    OpenAIRE

    Oh, Joo Hyun; Song, Seung Yong; Lew, Dae Hyun; Lee, Dong Won

    2016-01-01

    Summary: Siliconoma from ruptured breast implants has been reported in multiple body sites, including but not limited to the breast parenchyma, axillary lymph nodes, upper arm, and even lower leg. In this regard, we report a rare case of distant silicone migration to the lower extremities after traumatic breast implant rupture. A 55-year-old Asian woman who received bilateral augmentation mammoplasty 20 years ago presented with ruptured breast implants from a car accident 2 years earlier. Mag...

  12. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Amjad Alwaal

    2017-01-01

    Conclusions: There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  13. An “Uncrimped” SMart Stapes Prosthesis: A Cause of Late Hearing Deterioration in Otosclerosis

    Directory of Open Access Journals (Sweden)

    Premjit S. Randhawa

    2012-01-01

    Full Text Available Statement of Problem. Stapedotomy is the treatment of choice for otosclerosis. Numerous techniques and prosthesis are available to perform this procedure. Success rates of surgery vary from 17% to 80%, and revision surgery carries an increased risk of complications as well as poorer hearing outcomes. Method of Study. Case report. Results. We report the first case of uncrimping of a SMart stapes prosthesis with no lateral displacement as a cause of late failure despite successful crimping and improvement in audiological outcomes after initial surgery. Conclusion. The SMart stapes prosthesis is widely used and has been shown to be safe and provide good hearing outcomes. Displacement of a stapes prosthesis is the commonest cause of failure. Our case shows that deterioration of hearing thresholds can occur from uncrimping of the prosthesis with no displacement. It is important to improve our understanding of stapedotomy failure as revision procedures are associated with poorer outcomes.

  14. Prosthesis Prescription Protocol of the Arm (PPP-Arm) : The implementation of a national prosthesis prescription protocol

    NARCIS (Netherlands)

    Wijdenes, Paula; Brouwers, Michael; van der Sluis, Corry K

    BACKGROUND AND AIM: In order to create more uniformity in the prescription of upper limb prostheses by Dutch rehabilitation teams, the development and implementation of a Prosthesis Prescription Protocol of the upper limb (PPP-Arm) was initiated. The aim was to create a national digital protocol to

  15. PARTIAL REPLACEMENT OF THE ESOPHAGEAL MUSCLE LAYERS BY A CARBON-FIBER PROSTHESIS

    NARCIS (Netherlands)

    RUKA, MP; TUNGEKAR, MF; KUIT, J; HOFSTRA, W

    1991-01-01

    In the present study we report on the surgical replacement of the thoracic portion of oesophageal muscularis by a synthetic carbon fibre (CF) prosthesis in a rabbit model. Our results, as corroborated by the oesophagograms and the post-operative weight gain, showed that this prosthesis functioned

  16. Restoration of an atrophic eye socket with custom made eye prosthesis, utilizing digital photography

    Directory of Open Access Journals (Sweden)

    Gaurav P Jayaswal

    2011-01-01

    Full Text Available Ocular defects may cause several ocular and orbital disorders, which require surgical intervention. These defects are psychologically disturbing for the patients, and therefore, they require immediate management and rehabilitation by a team of specialist. Ocular prosthesis may be either readymade (stock or custom made. Fabrication of a custom ocular prosthesis allows for a range of variations during construction. The iris can also be custom made by ocular painting or by digital photography. The optimum cosmetic and functional results of a custom-made prosthesis enhance the patient′s rehabilitation to a normal life style. This paper elaborates the technique for fabrication of a custom-made ocular prosthesis for an atrophic eye socket utilizing digital photography.

  17. Nine-Year Core Study Data for Sientra's FDA-Approved Round and Shaped Implants with High-Strength Cohesive Silicone Gel.

    Science.gov (United States)

    Stevens, W Grant; Calobrace, M Bradley; Harrington, Jennifer; Alizadeh, Kaveh; Zeidler, Kamakshi R; d'Incelli, Rosalyn C

    2016-04-01

    Since approval in March 2012, data on Sientra's (Santa Barbara, CA) silicone gel implants have been updated and published regularly to provide immediate visibility to the continued safety and performance of these devices. The 9 year follow-up data support the previously published data confirming the ongoing safety and efficacy of Sientra silicone gel breast implants. The authors provide updated 9 year study data for Sientra's round and shaped silicone gel breast implants. The Core Study is an ongoing 10 year study that enrolled 1788 patients with 3506 Sientra implants across four indications (primary augmentation, revision-augmentation, primary reconstruction, and revision-reconstruction). For the safety analysis, Kaplan-Meier risk rates were calculated to evaluate postoperative complications, including all breast implant-related adverse effects. For the effectiveness analyses, results were presented through 8 years as patient satisfaction scores were assessed at even years. Through 9 years, the overall risk of capsular contracture was 12.6%. Smooth devices (16.6%, 95% CI, 14.2%, 19.5%) had a statistically significantly higher rate of capsular contracture compared to textured devices (8.0%, 95% CI, 6.2%, 10.4%). Out of the 610 reoperations in 477 patients, over half of all reoperations were due to cosmetic reasons (n = 315; 51.6%). Patient satisfaction remains high through 8 years, with 90% of primary augmentation patients indicating their breast implants look natural and feel soft. The 9-year follow-up data from the ongoing Core Study of the Sientra portfolio of HSC and HSC+ silicone gel breast implants reaffirm the very strong safety profile as well as continued patient satisfaction. 2 Therapeutic. © 2016 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  18. Optimization of Visual Information Presentation for Visual Prosthesis

    Directory of Open Access Journals (Sweden)

    Fei Guo

    2018-01-01

    Full Text Available Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis.

  19. Optimization of Visual Information Presentation for Visual Prosthesis

    Science.gov (United States)

    Gao, Yong

    2018-01-01

    Visual prosthesis applying electrical stimulation to restore visual function for the blind has promising prospects. However, due to the low resolution, limited visual field, and the low dynamic range of the visual perception, huge loss of information occurred when presenting daily scenes. The ability of object recognition in real-life scenarios is severely restricted for prosthetic users. To overcome the limitations, optimizing the visual information in the simulated prosthetic vision has been the focus of research. This paper proposes two image processing strategies based on a salient object detection technique. The two processing strategies enable the prosthetic implants to focus on the object of interest and suppress the background clutter. Psychophysical experiments show that techniques such as foreground zooming with background clutter removal and foreground edge detection with background reduction have positive impacts on the task of object recognition in simulated prosthetic vision. By using edge detection and zooming technique, the two processing strategies significantly improve the recognition accuracy of objects. We can conclude that the visual prosthesis using our proposed strategy can assist the blind to improve their ability to recognize objects. The results will provide effective solutions for the further development of visual prosthesis. PMID:29731769

  20. Trends in breast reconstruction: Implications for the National Health Insurance Service

    Directory of Open Access Journals (Sweden)

    Ki Yong Hong

    2018-05-01

    Full Text Available Background Breast reconstruction has become more common as mastectomy has become more frequent. In Korea, the National Health Insurance Service (NHIS began covering breast reconstruction in April 2015. This study aimed to investigate trends in mastectomy and breast reconstruction over the past 10 years and to evaluate the impact of NHIS coverage on breast reconstruction. Methods Nationwide data regarding mastectomy and breast reconstruction were collected from the Korean Breast Cancer Society registry database. Multiple variables were analyzed in the records of patients who underwent breast reconstruction from January 2005 to March 2017 at a single institution. Results At Seoul National University Hospital, the total number of reconstruction cases increased 13-fold from 2005 to 2016. The proportion of immediate breast reconstruction (IBR cases out of all cases of total mastectomy increased from 4% in 2005 to 52.0% in 2016. The proportion of delayed breast reconstruction (DBR cases out of all cases of breast reconstruction and the overall number of DBR cases increased from 8.8% (20 cases in 2012 to 18.3% (76 cases in 2016. After NHIS coverage was initiated, the proportions of IBR and DBR showed statistically significant increases (P<0.05. Among the IBR cases, the percentage of prosthesis-based reconstructions increased significantly (P<0.05, but this trend was not found with DBR. Total mastectomy became significantly more common after the expansion of NHIS coverage (P<0.05. Conclusions Over the last decade, there has been an increase in mastectomy and breast reconstruction, and the pace of increase accelerated after the expansion of NHIS coverage. It is expected that breast reconstruction will be a routine option for patients with breast cancer under the NHIS.

  1. 21 CFR 878.3750 - External prosthesis adhesive.

    Science.gov (United States)

    2010-04-01

    ... used to fasten to the body an external aesthetic restoration prosthesis, such as an artificial nose. (b) Classification. Class I (general controls). The device is exempt from the premarket notification procedures in...

  2. Development of a cosmetic knee disarticulation prosthesis : A single-patient case study

    NARCIS (Netherlands)

    de Laat, Fred A.; de Vos, Wouter; Geertzen, Jan; Roorda, Leo D.

    2015-01-01

    Background and aim: If a person does not become ambulant after an amputation, a knee disarticulation (KD) shouldbe considered and the person may then benefit from a cosmetic KD prosthesis. The features of a cosmetic KD prosthesis are, however, seldom described. The aim of this clinical note is to

  3. 21 CFR 888.3110 - Ankle joint metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ankle joint metal/polymer semi-constrained... Ankle joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An ankle joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an ankle...

  4. Methylene Blue Dye-Induced Skin Necrosis in Immediate Breast Reconstruction: Evaluation and Management

    Directory of Open Access Journals (Sweden)

    Ji Hwan Lee

    2014-05-01

    Full Text Available Background For early breast cancer patients, skin-sparing mastectomy or nipple-sparing mastectomy with sentinel lymph node biopsy has become the mainstream treatment for immediate breast reconstruction in possible cases. However, a few cases of skin necrosis caused by methylene blue dye (MBD used for sentinel lymph node localization have been reported. Methods Immediate breast reconstruction using a silicone implant was performed on 35 breasts of 34 patients after mastectomy. For sentinel lymph node localization, 1% MBD (3 mL was injected into the subareolar area. The operation site was inspected in the postoperative evaluation. Results Six cases of immediate breast reconstruction using implants were complicated by methylene blue dye. One case of local infection was improved by conservative treatment. In two cases, partial necrosis and wound dehiscence of the incision areas were observed; thus, debridement and closure were performed. Of the three cases of wide skin necrosis, two cases underwent removal of the dead tissue and implants, followed by primary closure. In the other case, the breast implant was salvaged using latissimus dorsi musculocutaneous flap reconstruction. Conclusions The complications were caused by MBD toxicity, which aggravated blood disturbance and skin tension after implant insertion. When planning immediate breast reconstruction using silicone implants, complications of MBD should be discussed in detail prior to surgery, and appropriate management in the event of complications is required.

  5. Conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees

    Directory of Open Access Journals (Sweden)

    Wilson Carlos da Silva Júnior

    Full Text Available Introduction Modern transfemoral knee prostheses are designed to offer comfort and self-confidence to amputees. These prostheses are mainly based upon either a passive concept, with a damping system, or an active computational intelligent design to control knee motion during the swing phase. In Brazil, most lower extremity amputees are unable to afford modern prostheses due to their high cost. In this work, we present the conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees. Methods The concept of the prosthesis is based on a control system with sensors for loads, which are installed on the amputee’s preserved leg and used as a mirror for the movement of the prosthesis. Mechanical strength analysis, using the Finite Element Method, electromechanical tests for the sensors and actuators and verification of data acquisition, signal conditioning and data transferring to the knee prosthesis were performed. Results The laboratory tests performed showed the feasibility of the proposed design. The electromechanical concept that was used enabled a controlled activation of the knee prosthesis by the two load cells located on the shoe sole of the preserved leg. Conclusions The electromechanical design concept and the resulting knee prosthesis show promising results concerning prosthesis activation during walking tests, thereby showing the feasibility of a reduced manufacturing cost compared to the modern prostheses available on the market.

  6. Self and partner satisfaction rates after 3 part inflatable penile prosthesis implantation.

    Science.gov (United States)

    Simsek, Abdulmuttalip; Kucuktopcu, Onur; Ozgor, Faruk; Ozkuvanci, Unsal; Baykal, Murat; Sarilar, Omer; Gurbuz, Zafer Gokhan

    2014-09-30

    To evaluate and present satisfaction rates of our patients and their partners after 3 part inflatable penile prosthesis implantation. We searched our hospital electronic data for patients who underwent inflatable penile prosthesis implantation between January 2008 and July 2013. Computer and archived file data were used to get information and reach the patients. We made telephone calls to patients and asked questionnaires about self and partner satisfaction rates. 36 patients underwent prosthesis implantation during the 5 year period. We were able to reach by telephone call 18 of them. The mean age of 18 patients was 55.7 ± 9.4 years and mean body mass index was 24.6 ± 2.1 kg/m2. The etiology was diabetes mellitus on 14 (77.8%) and radical pelvic surgery on 4 (22.2%) patients. 14 of 18 patients had penile Doppler ultrasound test. Doppler ultrasound demonstrated venous insufficiency in 8 and arterial insufficiency in 6 patients. Mean time from implantation to study was 20.8 ± 13.9 months. Out of 18 patients 2 had prosthesis removal operation because of infection in one patient and perforation in the other. Satisfaction rate was 88.9%, and recommendation rate was 94.4%. Causes of dissatisfaction were pain in one patient and insufficient rigidity plus shortening of the penis in the other one. Partner satisfaction rate was 94.4%. Penile Prosthesis Implantation (PPI) is the gold standard treatment of erectile dysfunction (ED) irresponsive to medical treatment. Infection and mechanical failure rates are going to be less according to the improvements in synthetic materials and coverings of the prosthesis, so patient and partner satisfaction rates will be higher.

  7. A prosthesis-specific multi-link segment model of lower-limb amputee sprinting.

    Science.gov (United States)

    Rigney, Stacey M; Simmons, Anne; Kark, Lauren

    2016-10-03

    Lower-limb amputees commonly utilize non-articulating energy storage and return (ESAR) prostheses for high impact activities such as sprinting. Despite these prostheses lacking an articulating ankle joint, amputee gait analysis conventionally features a two-link segment model of the prosthetic foot. This paper investigated the effects of the selected link segment model׳s marker-set and geometry on a unilateral amputee sprinter׳s calculated lower-limb kinematics, kinetics and energetics. A total of five lower-limb models of the Ottobock ® 1E90 Sprinter were developed, including two conventional shank-foot models that each used a different version of the Plug-in-Gait (PiG) marker-set to test the effect of prosthesis ankle marker location. Two Hybrid prosthesis-specific models were then developed, also using the PiG marker-sets, with the anatomical shank and foot replaced by prosthesis-specific geometry separated into two segments. Finally, a Multi-link segment (MLS) model was developed, consisting of six segments for the prosthesis as defined by a custom marker-set. All full-body musculoskeletal models were tested using four trials of experimental marker trajectories within OpenSim 3.2 (Stanford, California, USA) to find the affected and unaffected hip, knee and ankle kinematics, kinetics and energetics. The geometry of the selected lower-limb prosthesis model was found to significantly affect all variables on the affected leg (p prosthesis-specific spatial, inertial and elastic properties from full-body models significantly affects the calculated amputee gait characteristics, and we therefore recommend the implementation of a MLS model. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Maxillary palatal ramp prosthesis: A prosthodontic solution to manage mandibular deviation following surgery

    Directory of Open Access Journals (Sweden)

    Sampa Ray (Bhattacharya

    2015-01-01

    Full Text Available Mandibular resection following surgical treatment for neoplastic lesions of the oral cavity leads to numerous complications including altered mandibular movements, disfigurement, difficult in swallowing, impaired speech and articulation, and deviation of the mandible towards the resected site. Various prosthetic methods are employed to reduce or minimize mandibular deviation and improve and restore the lost functions and esthetic, like maxillomandibular fixation, implant supported prosthesis, removable mandibular guide flange prosthesis, and palatal based guidance restoration. This clinical report describes the rehabilitation of a patient following segmental mandibulectomy using palatal ramp prosthesis.

  9. A new and simple method of fabrication of tracheostomal prosthesis

    Directory of Open Access Journals (Sweden)

    N Vidya Sankari

    2015-01-01

    Full Text Available Patients with a tracheostomy stoma experience compromised speech and function due to the associated changes in airflow patterns. Rehabilitation of a patient with tracheal stoma is a highly challenging task. The main objective is to design an inexpensive, easily fabricated stomal prosthesis for postlaryngectomy patients who require prolonged tracheotomy. This clinical case report describes a 29-year-old male patient who underwent for tracheotomy 3 months before for respiratory distress following a suicidal attempt. Hence tracheotomy was done, and the patient has been with the tracheostomal tube since surgery for the past 3 months. Laryngoscopy examination reported as restricted bilateral vocal cord movements, and the cords were in the adducted position with minimal glottic chink. No history of difficulty in swallowing. On examination, no scar or ulceration is seen around the stoma. The skin around the stoma is healthy. The patient was referred to the oral and maxillofacial Prosthodontics Department from the Department of ENT. The patient′s old tracheostomal tube was used as the dimensions of the custom made tracheal prosthesis without making a functional impression of the mature stoma. A tracheal button was made with 2 mm polyethylene urethane sheet to maintain the airway patency of the mature stoma. Width and length of the old tracheostomal tube were measured and customized with polyurethane sheet by directly flaming over heat. The finished product was thin, flexible, maintains enhanced tear strength, require no tapes or adhesives and less technique sensitive. These properties of the prosthesis make more advantageous than the commercially available tracheal buttons. The result in this patient was excellent with no postoperative complications. An innovative approach for fabrication of tracheostomal prosthesis was discussed to increase its successful use in tracheostomal patients. The patient′s old tracheostomal tube was used as the dimensions

  10. Game-Based Rehabilitation for Myoelectric Prosthesis Control.

    Science.gov (United States)

    Prahm, Cosima; Vujaklija, Ivan; Kayali, Fares; Purgathofer, Peter; Aszmann, Oskar C

    2017-02-09

    A high number of upper extremity myoelectric prosthesis users abandon their devices due to difficulties in prosthesis control and lack of motivation to train in absence of a physiotherapist. Virtual training systems, in the form of video games, provide patients with an entertaining and intuitive method for improved muscle coordination and improved overall control. Complementary to established rehabilitation protocols, it is highly beneficial for this virtual training process to start even before receiving the final prosthesis, and to be continued at home for as long as needed. The aim of this study is to evaluate (1) the short-term effects of a commercially available electromyographic (EMG) system on controllability after a simple video game-based rehabilitation protocol, and (2) different input methods, control mechanisms, and games. Eleven able-bodied participants with no prior experience in EMG control took part in this study. Participants were asked to perform a surface EMG test evaluating their provisional maximum muscle contraction, fine accuracy and isolation of electrode activation, and endurance control over at least 300 seconds. These assessments were carried out (1) in a Pregaming session before interacting with three EMG-controlled computer games, (2) in a Postgaming session after playing the games, and (3) in a Follow-Up session two days after the gaming protocol to evaluate short-term retention rate. After each game, participants were given a user evaluation survey for the assessment of the games and their input mechanisms. Participants also received a questionnaire regarding their intrinsic motivation (Intrinsic Motivation Inventory) at the end of the last game. Results showed a significant improvement in fine accuracy electrode activation (Pgames when collecting items and facing challenging game play. Most upper limb amputees use a 2-channel myoelectric prosthesis control. This study demonstrates that this control can be effectively trained by

  11. [Tripolar arthroplasty for recurrent total hip prosthesis dislocation].

    Science.gov (United States)

    Beaulé, P-E; Roussignol, X; Schmalzried, T-P; Udomkiat, P; Amstutz, H-C; Dujardin, F-H

    2003-05-01

    The purpose of this study was to assess the results of revision surgery for recurrent total hip prosthesis dislocation using a tripolar prosthesis composed of a conventional stem with a mobile head of an intermediary prosthesis measuring more than 40 mm and a modified cup. This technique was used in two centers in Rouen France and Los Angeles USA. Twenty-one hips in 21 patients were operated on. The mobile heads measured 40 to 47 mm. Mean patient age was 70 years (range 29-92). The indication for the tripolar prosthesis was reserved for extremely unstable hips in patients with major risk factors for recurrent dislocation. These 21 patients had experienced 95 dislocations. The acetabular cup was custom-made for the large-diameter heads. A cemented polyethylene cup was used in 14 cases and a press-fit metal-backed around a polyethylene insert in 7. The polyethylene thickness varied from 6.5 to 16 mm for the cemented cups and 4 to 5 mm for the press-fit cups. Fourteen femoral stems were left in place as were two press-fit cups where only the inserts were changed. Mean follow-up was 5.4 years (range 3-11.8). There has been no recurrent dislocation for 20 hips. One patient experienced a dislocation one week after surgery which required a second revision procedure to reposition the acetabular implant. Final outcome was good at 7.6 years for this hip. One patient who had not had any recurrent dislocation died 4 years after the revision surgery due to a cause unrelated to the prosthesis. Two patients were lost to follow-up at 3.7 and 6 years, both were pain free and had no radiological anomalies. Infection occurred in one patient undergoing chemotherapy for a myeloma; the head and neck had to be resected. For the 20 other patients, functional outcome, assessed with the UCLA score, showed improvement in pain (5.8 preoperatively, 9.2 at last follow-up), walking (4.8 and 8 respectively), function (4 and 6 respectively), and daily activities (3.3 and 5.2 respectively). A

  12. An Underreported Consequence of Obesity in Pregnancy: Patient-Prosthesis Mismatch

    OpenAIRE

    Hartman, William R.; Arendt, Katherine W.; Rehfeldt, Kent H.

    2012-01-01

    As the rate of obesity increases in childbearing-aged women, so too will the complications of obesity in pregnancy. An uncommon and likely underreported complication occurs in obese women who have received prepregnancy cardiac valve replacement with a prosthesis that is inadequately sized for body habitus, a condition referred to as patient-prosthesis mismatch (PPM). The physiologic changes of pregnancy as well as the increased weight gain combine to exacerbate PPM. We report a case of PPM th...

  13. A custom-made temporomandibular joint prosthesis for fabrication by selective laser melting: Finite element analysis.

    Science.gov (United States)

    Xu, Xiangliang; Luo, Danmei; Guo, Chuanbin; Rong, Qiguo

    2017-08-01

    A novel and custom-made selective laser melting (SLM) 3D-printed alloplastic temporomandibular joint (TMJ) prosthesis is proposed. The titanium-6aluminium-4vanadium (Ti-6Al-4V) condyle component and ultra-high molecular weight polyethylene (UHMWPE) fossa component comprised the total alloplastic TMJ replacement prosthesis. For the condyle component, an optimized tetrahedral open-porous scaffold with combined connection structures, i.e. an inlay rod and an onlay plate, between the prosthesis and remaining mandible was designed. The trajectory of movement of the intact condyle was assessed via kinematic analysis to facilitate the design of the fossa component. The behaviours of the intact mandible and mandible with the prosthesis were compared. The biomechanical behaviour was analysed by assessing the stress distribution on the prosthesis and strain distribution on the mandible. After muscle force was applied, the magnitude of the compressive strain on the condyle neck of the mandible with the prosthesis was lower than that on the condyle neck of the intact mandible, with the exception of the area about the screws; additionally, the magnitude of the strain at the scaffold-bone interface was relatively high. Copyright © 2017. Published by Elsevier Ltd.

  14. Cancer risk among Danish women with cosmetic breast implants

    DEFF Research Database (Denmark)

    Friis, Søren; Hölmich, Lisbet R; McLaughlin, Joseph K

    2006-01-01

    The available epidemiologic evidence does not support a carcinogenic effect of silicone breast implants on breast or other cancers. Data on cancer risk other than breast cancer are limited and few studies have assessed cancer risk beyond 10-15 years after breast implantation. We extended follow...... proportional hazards models, adjusting for age, calendar period and reproductive history. We observed 163 cancers among women with breast implants compared to 136.7 expected based on general population rates (SIR = 1.2; 95% confidence interval [CI] = 1.0-1.4), during a mean follow-up period of 14.4 years...... (range = 0-30 years). Women with breast implants experienced a reduced risk of breast cancer (SIR = 0.7; 95% CI = 0.5-1.0), and an increased risk of non-melanoma skin cancer (SIR = 2.1; 95% CI = 1.5-2.7). Stratification by age at implantation, calendar year at implantation and time since implantation...

  15. Potential costs of breast augmentation mammaplasty.

    Science.gov (United States)

    Schmitt, William P; Eichhorn, Mitchell G; Ford, Ronald D

    2016-01-01

    Augmentation mammaplasty is one of the most common surgical procedures performed by plastic surgeons. The aim of this study was to estimate the cost of the initial procedure and its subsequent complications, as well as project the cost of Food and Drug Administration (FDA)-recommended surveillance imaging. The potential costs to the individual patient and society were calculated. Local plastic surgeons provided billing data for the initial primary silicone augmentation and reoperative procedures. Complication rates used for the cost analysis were obtained from the Allergen Core study on silicone implants. Imaging surveillance costs were considered in the estimations. The average baseline initial cost of silicone augmentation mammaplasty was calculated at $6335. The average total cost of primary breast augmentation over the first decade for an individual patient, including complications requiring reoperation and other ancillary costs, was calculated at $8226. Each decade thereafter cost an additional $1891. Costs may exceed $15,000 over an averaged lifetime, and the recommended implant surveillance could cost an additional $33,750. The potential cost of a breast augmentation, which includes the costs of complications and imaging, is significantly higher than the initial cost of the procedure. Level III, economic and decision analysis study. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. In vitro deflation of prefilled saline breast implants.

    Science.gov (United States)

    Stevens, W Grant; Hirsch, Elliot M; Stoker, David A; Cohen, Robert

    2006-08-01

    The purpose of this study was to determine whether or not prefilled breast implants retain their volume in packaging. This study examined 32 Poly Implant Prosthesis prefilled textured saline breast implants. All of these implants were within the manufacturer's expiration date at the time of weighing. No holes were visible on any of the implants. All were weighed on an electronic scale. The measured weight was compared with the expected weight (based on the implant size as specified by the manufacturer) and the percentage deflation was calculated. The manufacturer declined to provide specific information about the manufacture dates of the implants; thus, relative age (rather than absolute age) was examined with respect to percentage deflation. Of the 32 implants examined, all showed some degree of deflation (range, 8.84 to 57.14 percent; 95 percent confidence interval of the mean, 22.01 +/- 4.17 percent). There was a moderate correlation (r = 0.41) between relative age of the implant and percentage deflation. From these results, it is clear that this type of prefilled saline breast implant does not maintain its volume in vitro. If these implants are used, the underfilling could contribute to a higher deflation rate and cosmetic deformity. This risk should be taken into account by plastic surgeons who use this type of implant in breast augmentation procedures.

  17. Elektra prosthesis for trapeziometacarpal osteoarthritis

    DEFF Research Database (Denmark)

    Klahn, A; Nygaard, Mads; Gvozdenovic, R

    2012-01-01

    We present a prospective follow-up of 39 Elektra prostheses in 37 patients (32 women and five men), with a mean age of 56.5 (range 46-71) years; 34 patients had osteoarthritis and three had rheumatoid arthritis. Patients were followed using clinical examination, including measurement of pain...... be the key problem in treating trapeziometacarpal osteoarthritis using a total prosthesis....

  18. Customization of stock eye prosthesis for a pediatric patient by a simplified technique.

    Science.gov (United States)

    Jurel, Sunit Kumar; Talwar, Naina; Chand, Pooran; Singh, Raghuwar D; Gupta, Durga Shanker

    2012-05-01

    The unfortunate loss or absence of an eye may be caused by congenital defect , irreparable trauma, tumor or blind eye. The role of the maxillofacial prosthodontist in fabricating an ocular prosthesis to restore facial symmetry and normal appearance for the anophthalmic patient becomes essential. A custom-made ocular prosthesis is an excellent alternative for the people who lose their eye especially in young age. It has acceptable fit, retention and esthetics but is technically difficult to fabricate. On the other hand the stock eye has compromised fit and poor esthetics. Our case report presents a simple technique of customization of stock eye prosthesis to provide accurate fit and acceptable esthetics. How to cite this article: Jurel SK, Talwar N, Chand P, Singh RD, Gupta DS. Customization of Stock Eye Prosthesis for a Pediatric Patient by a Simplified Technique. Int J Clin Pediatr Dent 2012;5(2):155-158.

  19. Prosthetic breast reconstruction: indications and update

    Science.gov (United States)

    Quinn, Tam T.; Miller, George S.; Rostek, Marie; Cabalag, Miguel S.; Rozen, Warren M.

    2016-01-01

    Background Despite 82% of patients reporting psychosocial improvement following breast reconstruction, only 33% patients choose to undergo surgery. Implant reconstruction outnumbers autologous reconstruction in many centres. Methods A systematic review of the literature was undertaken. Inclusion required: (I) Meta-analyses or review articles; (II) adult patients aged 18 years or over undergoing alloplastic breast reconstruction; (III) studies including outcome measures; (IV) case series with more than 10 patients; (V) English language; and (VI) publication after 1st January, 2000. Results After full text review, analysis and data extraction was conducted for a total of 63 articles. Definitive reconstruction with an implant can be immediate or delayed. Older patients have similar or even lower complication rates to younger patients. Complications include capsular contracture, hematoma and infection. Obesity, smoking, large breasts, diabetes and higher grade tumors are associated with increased risk of wound problems and reconstructive failure. Silicone implant patients have higher capsular contracture rates but have higher physical and psychosocial function. There were no associations made between silicone implants and cancer or systemic disease. There were no differences in outcomes or complications between round and shaped implants. Textured implants have a lower risk of capsular contracture than smooth implants. Smooth implants are more likely to be displaced as well as having higher rates of infection. Immediate breast reconstruction (IBR) gives the best aesthetic outcome if radiotherapy is not required but has a higher rate of capsular contracture and implant failure. Delayed-immediate reconstruction patients can achieve similar aesthetic results to IBR whilst preserving the breast skin if radiotherapy is required. Delayed breast reconstruction (DBR) patients have fewer complications than IBR patients. Conclusions Implant reconstruction is a safe and popular

  20. The In Vivo Pericapsular Tissue Response to Modern Polyurethane Breast Implants.

    Science.gov (United States)

    Frame, James; Kamel, Dia; Olivan, Marcelo; Cintra, Henrique

    2015-10-01

    Polyurethane breast implants were first introduced by Ashley (Plast Reconstr Surg 45:421-424, 1970), with the intention of trying to reduce the high incidence of capsular contracture associated with smooth shelled, high gel bleed, silicone breast implants. The sterilization of the polyurethane foam in the early days was questionable. More recently, ethylene oxide (ETO)-sterilized polyurethane has been used in the manufacturing process and this has been shown to reduce the incidence of biofilm. The improved method of attachment of polyurethane onto the underlying high cohesive gel, barrier shell layered, silicone breast implants also encourages bio-integration. Polyurethane covered, cohesive gel, silicone implants have also been shown to reduce the incidence of other problems commonly associated with smooth or textured silicone implants, especially with reference to displacement, capsular contracture, seroma, reoperation, biofilm and implant rupture. Since the introduction of the conical polyurethane implant (Silimed, Brazil) into the United Kingdom in 2009 (Eurosurgical, UK), we have had the opportunity to review histology taken from the capsules of polyurethane implants in three women ranging from a few months to over 3 years after implantation. All implants had been inserted into virgin subfascial, extra-pectoral planes. The results add to the important previously described histological findings of Bassetto et al. (Aesthet Plast Surg 34:481-485, 2010). Five distinct layers are identified and reasons for the development of each layer are discussed. Breast capsule around polyurethane implants, in situ for fifteen and 20 years, has recently been obtained and analysed in Brazil, and the histology has been incorporated into this study. After 20 years, the polyurethane is almost undetectable and capsular contracture may appear. These findings contribute to our understanding of polyurethane implant safety, and give reasoning for a significant reduction in clinical

  1. Difference in occurrence of heterotopic ossification according to prosthesis type in the cervical artificial disc replacement.

    Science.gov (United States)

    Yi, Seong; Kim, Keung Nyun; Yang, Moon Sul; Yang, Joong Won; Kim, Hoon; Ha, Yoon; Yoon, Do Heum; Shin, Hyun Chul

    2010-07-15

    Retrospective study of the difference of heterotopic ossification (HO) occurrence according to 3 different types of prosthesis. This study was designed to investigate the difference of HO occurrence according to different type of prosthesis. HO is defined as formation of the bone outside the skeletal system. Reported HO occurrence rate in cervical artificial disc replacement (ADR) was unexpectedly high and varied. But the influencing factors of HO in cervical ADR have not been elucidated well. The prosthesis-related factors for making difference of HO occurrence were investigated in this study. A total of 170 patients undergoing cervical arthroplasty with the Bryan cervical disc prosthesis (Medtroic Sofamor Danek, Memphis, TN), Mobi-C disc prosthesis (LDR Medical, Troyes, France), and ProDisc-C (Synthes, Inc., West Chester, PA) were included. Cervical lateral radiographs obtained before and after surgery were used to identify HO. Occurrence rate, occurrence-free period, location, and grade of HOs were investigated according to the different prosthesis. Each prosthesis group included patients as follows: Bryan disc, 81 patients; Mobi-C, 61 patients; and ProDisc-C, 28 patients. Overall HO rate was 40.6% (69 of 170 patients). Each HO occurrence rate by prosthesis was as follows: the Bryan disc group, 21.0%; Mobi-C group, 52.5%; and the ProDisc-C group, 71.4%. In the survival analysis, all patients showed 27.1 +/- 3.7 months as the median survival. The Bryan disc group showed statistically longer survival (48.4 +/- 7.4 months) than the other groups. Occurrence of HO is an inevitable postoperative complication after cervical ADR. The occurrence rate of HO was higher than our expectation. Moreover, definite differences in occurrence rate according to the prosthesis type were identified by this study.

  2. Influence of type of aortic valve prosthesis on coronary blood flow velocity.

    Science.gov (United States)

    Jelenc, Matija; Juvan, Katja Ažman; Medvešček, Nadja Tatjana Ružič; Geršak, Borut

    2013-02-01

    Severe aortic valve stenosis is associated with high resting and reduced hyperemic coronary blood flow. Coronary blood flow increases after aortic valve replacement (AVR); however, the increase depends on the type of prosthesis used. The present study investigates the influence of type of aortic valve prosthesis on coronary blood flow velocity. The blood flow velocity in the left anterior descending coronary artery (LAD) and the right coronary artery (RCA) was measured intraoperatively before and after AVR with a stentless bioprosthesis (Sorin Freedom Solo; n = 11) or a bileaflet mechanical prosthesis (St. Jude Medical Regent; n = 11). Measurements were made with an X-Plore epicardial Doppler probe (Medistim, Oslo, Norway) following induction of hyperemia with an adenosine infusion. Preoperative and postoperative echocardiography evaluations were used to assess valvular and ventricular function. Velocity time integrals (VTI) were measured from the Doppler signals and used to calculate the proportion of systolic VTI (SF), diastolic VTI (DF), and normalized systolic coronary blood flow velocities (NSF) and normalized diastolic coronary blood flow velocities (NDF). The systolic proportion of the LAD VTI increased after AVR with the St. Jude Medical Regent prosthesis, which produced higher LAD SF and NSF values than the Sorin Freedom Solo prosthesis (SF, 0.41 ± 0.09 versus 0.29 ± 0.13 [P = .04]; NSF, 0.88 ± 0.24 versus 0.55 ± 0.17 [P = .01]). No significant changes in the LAD velocity profile were noted after valve replacement with the Sorin Freedom Solo, despite a significant reduction in transvalvular gradient and an increase in the effective orifice area. AVR had no effect on the RCA flow velocity profile. The coronary flow velocity profile in the LAD was significantly influenced by the type of aortic valve prosthesis used. The differences in the LAD velocity profile probably reflect differences in valve design and the systolic transvalvular flow pattern.

  3. Self and partner satisfaction rates after 3 part inflatable penile prosthesis implantation

    Directory of Open Access Journals (Sweden)

    Abdulmuttalip Simsek

    2014-09-01

    Full Text Available Objective: To evaluate and present satisfaction rates of our patients and their partners after 3 part inflatable penile prosthesis implantation. Materials and methods: We searched our hospital electronic data for patients who underwent inflatable penile prosthesis implantation between January 2008 and July 2013. Computer and archived file data were used to get information and reach the patients. We made telephone calls to patients and asked questionnaires about self and partner satisfaction rates. Results: 36 patients underwent prosthesis implantation during the 5 year period. We were able to reach by telephone call 18 of them. The mean age of 18 patients was 55.7 ± 9.4 years and mean body mass index was 24.6 ± 2.1 kg/m2. The etiology was diabetes mellitus on 14 (77.8% and radical pelvic surgery on 4 (22.2% patients. 14 of 18 patients had penile Doppler ultrasound test. Doppler ultrasound demonstrated venous insufficiency in 8 and arterial insufficiency in 6 patients. Mean time from implantation to study was 20.8 ± 13.9 months. Out of 18 patients 2 had prosthesis removal operation because of infection in one patient and perforation in the other. Satisfaction rate was 88.9%, and recommendation rate was 94.4%. Causes of dissatisfaction were pain in one patient and insufficient rigidity plus shortening of the penis in the other one. Partner satisfaction rate was 94.4%. Conclusion: Penile Prosthesis Implantation (PPI is the gold standard treatment of erectile dysfunction (ED irresponsive to medical treatment. Infection and mechanical failure rates are going to be less according to the improvements in synthetic materials and coverings of the prosthesis, so patient and partner satisfaction rates will be higher.

  4. Hip arthroplasty. Part 1: prosthesis terminology and classification

    International Nuclear Information System (INIS)

    Pluot, E.; Davis, E.T.; Revell, M.; Davies, A.M.; James, S.L.J.

    2009-01-01

    Hip arthroplasty is an extremely common orthopaedic procedure and there is a wide array of implants that are in current use in the UK. The follow-up of patients who have undergone insertion of a hip prosthesis is shifting from a consultant-lead hospital service towards primary care. As this change in patient care continues it becomes increasingly important that an accurate description of the radiographic features is communicated to the primary-care practitioner so appropriate specialist input can be triggered. This review focuses on the terminology and classification of hip prostheses. This acts as a precursor for Part 2 of this series, which describes the normal and abnormal radiographic findings following hip prosthesis insertion.

  5. 21 CFR 888.3565 - Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial metal/polymer... Devices § 888.3565 Knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis. (a) Identification. A knee joint patellofemorotibial metal/polymer porous-coated uncemented prosthesis is a device...

  6. 21 CFR 888.3550 - Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemorotibial polymer/metal/metal... § 888.3550 Knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis. (a) Identification. A knee joint patellofemorotibial polymer/metal/metal constrained cemented prosthesis is a device...

  7. 21 CFR 888.3490 - Knee joint femorotibial metal/composite non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite non... § 888.3490 Knee joint femorotibial metal/composite non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite non-constrained cemented prosthesis is a device...

  8. Eliciting Naturalistic Cortical Responses with a Sensory Prosthesis via Optimized Microstimulation

    Science.gov (United States)

    2016-08-12

    Eliciting naturalistic cortical responses with a sensory prosthesis via optimized microstimulation John S Choi1, Austin J Brockmeier2, David B...applied to single electrodes in the ventral caudal thalamus evoke percepts that are both place and modality-specific, and yet ‘unnatural’ in feeling ...information on touch parameters, they do so with the same timing, as would be expected for a biomimetic sensory prosthesis . The discriminability of natural

  9. Restoring Proprioception via a Cortical Prosthesis: A Novel Learning Based Approach

    Science.gov (United States)

    2016-10-01

    AWARD NUMBER: W81XWH-14-1-0510 TITLE: Restoring Proprioception via a Cortical Prosthesis : A Novel Learning-Based Approach PRINCIPAL INVESTIGATOR...Sep 2015 - 29 Sep 2016 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Restoring Proprioception via a Cortical Prosthesis : A Novel Learning-Based...the feeling of where the body is in space. The importance of proprioception is often not appreciated; without it, we are unable to move normally

  10. An experimental-numerical method for comparative analysis of joint prosthesis

    International Nuclear Information System (INIS)

    Claramunt, R.; Rincon, E.; Zubizarreta, V.; Ros, A.

    2001-01-01

    The difficulty that exists in the analysis of mechanical stresses in bones is high due to its complex mechanical and morphological characteristics. This complexity makes generalists modelling and conclusions derived from prototype tests very questionable. In this article a relatively simple comparative analysis systematic method that allow us to establish some behaviour differences in different kind of prosthesis is presented. The method, applicable in principle to any joint problem, is based on analysing perturbations produced in natural stress states of a bone after insertion of a joint prosthesis and combines numerical analysis using a 3-D finite element model and experimental studies based on photoelastic coating and electric extensometry. The experimental method is applied to compare two total hip prosthesis cement-free femoral stems of different philosophy. One anatomic of new generation, being of oblique setting over cancellous bone and the other madreporique of trochantero-diaphyseal support over cortical bone. (Author) 4 refs

  11. Imaging of common breast implants and implant-related complications: A pictorial essay.

    Science.gov (United States)

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  12. High resolution PET breast imager with improved detection efficiency

    Science.gov (United States)

    Majewski, Stanislaw

    2010-06-08

    A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.

  13. 21 CFR 888.3530 - Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer semi... § 888.3530 Knee joint femorotibial metal/polymer semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer semi-constrained cemented prosthesis is a device intended...

  14. 21 CFR 888.3540 - Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellofemoral polymer/metal semi... § 888.3540 Knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis. (a) Identification. A knee joint patellofemoral polymer/metal semi-constrained cemented prosthesis is a two-part...

  15. 21 CFR 888.3500 - Knee joint femorotibial metal/composite semi-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/composite semi... § 888.3500 Knee joint femorotibial metal/composite semi-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/composite semi-constrained cemented prosthesis is a two-part...

  16. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  17. 21 CFR 888.3520 - Knee joint femorotibial metal/polymer non-constrained cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint femorotibial metal/polymer non... § 888.3520 Knee joint femorotibial metal/polymer non-constrained cemented prosthesis. (a) Identification. A knee joint femorotibial metal/polymer non-constrained cemented prosthesis is a device intended to...

  18. 21 CFR 888.3580 - Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint patellar (hemi-knee) metallic... § 888.3580 Knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint patellar (hemi-knee) metallic resurfacing uncemented prosthesis is a device made of...

  19. Usefulness of positron emission tomography (TEP) in the assessment of osteo-articular prosthesis

    International Nuclear Information System (INIS)

    Maldonado, A.; Suarez, J.P.; Dominguez, M.L.

    2004-01-01

    Joint arthroplasty is performed with increasing frequency as the population ages. Loosening or infection of the prosthesis is a relatively common event that can limit the lifetime of a prosthesis. Accuracy differentiation between aseptic and septic loosening of the prosthesis remains a challenge because of the consequences for patient management. Moreover, an early diagnosis of infected hip prosthesis is very important for optimal and cost-effective management. Various approaches have developed to visualize infection and inflammation by nuclear medicine techniques. Recently positron emission tomography (PET) with fluorine-l8 labelled 2 fluoro-2-deoxyglucose ( 18 F-FDG) has been shown to delineate infectious and inflammatory foci with high sensitivity owing to the increased glucose metabolism in inflammatory cells. In this paper we review the role of FDG-PET in this common differential diagnosis in patients with total knee and hip prostheses. Different patterns of FDG-PET interpretation have been described as wed as methodological aspects. (author)

  20. [Phonomechanocardiography in the evaluation of the functional status of valvular prosthesis].

    Science.gov (United States)

    Esquivel Avila, J; Molina Zapata, B; Martínez Ríos, M A; Flamand, E

    1975-01-01

    The FMCG in 22 patients with valvular prosthesis is analyzed and its clinical, hemodynamic and surgical correlation are established (11 from the I.N.C. and 11 from the Hospital Infantil I.M.A.N.). The average age of the patients was 15 years old, 18 had a mitral and six aortic valvulopathy, and they all required a valvular replacement. Of the mitral prosthesis, 14 were Starr-Edwards (13 of ball valve and one of disc), three Lillehei-Kaster and one Börck-Shiley. In 5 patients, the FMCG suspected disfunction that was later corroborated by catheterism in three patients and by surgery in all of them. The important differences of the FMCG between the group with good and the one with bad function were: the aparition of a rumble, a decrease in the amplitud of the closing snap, index of closing snap opering snap of less than one, lenghtening of fases PFVP and IVCP, and shortening of IVDRP. In the patients with auricular fibrilation, after long dyastoles; that would represent an adequate atrial emptying; the closing snap was more intense, the PFVP was lennthened the IVDRP was shortened when the prosthesis was not properly functioning. All the aortic prosthesis were ball valve Starr-Edwards type; in one the FMCG suspected disfunction and the patient had a sudden death outside of the Hospital. The significant differences of the FMCG were the decrease in the intensity of the opening snap, with a Hylen index of less than one, lengthening of the PFVP, IVCP and of the expulsive period (EP). The authors conclude that the FMCG is a good method for an early detection of the disfunctions of valvular prosthesis.

  1. The effect of silicone implants on the diagnosis, prognosis, and treatment of breast cancer.

    Science.gov (United States)

    Handel, Neal

    2007-12-01

    Because of the prevalence of breast cancer, many augmented women eventually will develop the disease. This article reviews what is known about the effect of implants on the detection, prognosis, and treatment of carcinoma of the breast. Observations were made on 4082 breast cancer patients (3953 nonaugmented and 129 augmented) treated over a 23-year time span. Findings in the two groups were compared and differences analyzed statistically. Mammograms of all women with palpable lesions were reviewed to assess mammographic sensitivity in patients with and without implants. Cosmetic outcomes in augmented patients treated with breast conservation therapy were reviewed. Augmented patients presented more frequently with palpable lesions, invasive tumors, axillary nodal metastases, and false-negative mammograms. However, there was no significant difference in stage of disease, tumor size, recurrence rates, or survival between the two groups. Augmented patients treated with breast conservation therapy often experienced poor cosmetic results and frequently required reoperation. Despite the diminished sensitivity of mammography in women with implants, augmented and nonaugmented patients are diagnosed at a similar stage of disease and have a comparable prognosis. Implants may impair mammography but appear to facilitate tumor detection on physical examination. Magnetic resonance imaging and breast ultrasound may be useful adjuncts, but conventional mammography remains the most reliable tool for diagnosing early breast cancer in augmented patients. Breast implants do not interfere with mastectomy or breast reconstruction but may compromise the outcome of breast conservation therapy.

  2. [Longterm results of cervical arthroplasty with disc prosthesis. A literature review].

    Science.gov (United States)

    Fransen, P; Schils, F

    2014-01-01

    Cervical arthroplasty has now been performed for over 10 years. Despite the large number of implanted artificial discs, the quality of the published studies is weak, and very few report a follow up exceeding two years. We reviewed the literature on cervical total disc replacement, focusing on publications reporting a follow-up of more than two years. The selection of patients, the type of implant and the surgical technique seem to influence greatly the quality of the clinical and radiological results. The occurrence of heterotopic ossifications around the implant seems to be the rule rather than the exception. Wear debris are likely to be observed in the vicinity of the prosthesis. Most long term studies also report a progressive decrease in the range of motion of the prosthesis, although without influence on the clinical evolution. It seems reasonable to say that cervical disc prosthesis is not inferior to discectomy and fusion, and that these implants allow a short term preservation of cervical mobility, but the efficacy in preventing adjacent segment disease or a favourable costleffectiveness ratio have yet to be demonstrated. A more widespread use of cervical disc prosthesis can only be suggested when these questions have been answered by long term follow-up studies.

  3. Quality of life among lower limb prosthesis users attending Artificial Limb Center of Fauji Foundation Hospital Rawalpindi

    International Nuclear Information System (INIS)

    Kalsoom, U.; Bairam, S.

    2018-01-01

    To assess quality of life and the influencing factors as perceived by lower limb prosthesis users. Study Design: Cross sectional study. Place and Duration of Study: Artificial Limb Centre, Fauji Foundation Hospital Rawalpindi, 11 months (Jan to Nov 2014). Material and Methods: A sample of 50 patients with lower limb amputations and using lower limb prosthesis were recruited by applying inclusion criteria. Responses were recorded on demographic variables, reasons for amputation, time of provision of prosthesis, employment status etc. by the investigator on a structured pretested questionnaire after their consent. A p-value of <0.05 was taken as significant. Quality of life was interpreted on 5 point Likert scale. Data was analyzed in SPSS version 21. Result: Majority of respondents i.e. 17 (34%) were in 51-60 years age group with mean age 46 +- 14 years while 33 (66%) were males and 27 (54%) illiterate, 33 (66%) could afford a prosthesis. Trauma 28 (56%) was the most prevalent cause of lower limb amputation and among them 15 (53%) had road accident injuries. Various factors influenced quality of life as perceived by the respondents and in 10 (20%), 16 (32%), 25 (50%) social, family life and emotional status was affected respectively, while 14 (28%) of the prosthesis user were unemployed. Prosthesis were provided after 2 years in 18 (36%) and in 37 (74%) prosthesis were provided by the health care facility. Good quality of life was perceived in 40 (80%) respondents. Conclusion: Perceived Quality of life was good in majority of the prosthesis users but others can't be ignored. It can be improved by early provision of prosthesis which can help in better employment opportunities. (author)

  4. Different types of implants for reconstructive breast surgery.

    Science.gov (United States)

    Rocco, Nicola; Rispoli, Corrado; Moja, Lorenzo; Amato, Bruno; Iannone, Loredana; Testa, Serena; Spano, Andrea; Catanuto, Giuseppe; Accurso, Antonello; Nava, Maurizio B

    2016-05-16

    Breast cancer is the most common cancer in women worldwide, and is a leading cause of cancer death among women. Prophylactic or curative mastectomy is often followed by breast reconstruction for which there are several surgical approaches that use breast implants with which surgeons can restore the natural feel, size and shape of the breast. To assess the effects of different types of breast implants on capsular contracture, surgical short- and long-term complications, postoperative satisfaction level and quality of life in women who have undergone reconstructive breast surgery after mastectomy. We searched the Cochrane Breast Cancer Group's Specialised Register on 20 July 2015, MEDLINE (1985 to 20 July 2015), EMBASE (1985 to 20 July 2015) and the Cochrane Central Register of Controlled Trials (CENTRAL; Issue 8, 2015). We also searched the World Health Organization's International Clinical Trials Registry Platform (WHO ICTRP) and ClinicalTrials.gov on 16 July 2015. We included randomised controlled trials (RCTs) and quasi-RCTs that compared different types of breast implants for reconstructive surgery. We considered the following types of intervention: implant envelope surfaces - texturised versus smooth; implant filler material - silicone versus saline, PVP-Hydrogel versus saline; implant shape - anatomical versus round; implant volume - variable versus fixed; brands - different implant manufacturing companies and implant generation (fifth versus previous generations). Two review authors independently assessed methodological quality and extracted data. We used standard Cochrane methodological procedures. The quality of the evidence was assessed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. Five RCTs with 202 participants met the inclusion criteria. The women participants were typically in their 50s, and the majority of them (about 82%) received reconstructive surgery following breast cancer, while the others had

  5. Experimental Assessment of a New Type of Carbon-Coated ARTECOR® Vascular Prosthesis in Sheep

    Directory of Open Access Journals (Sweden)

    Jiří Podlaha

    2009-01-01

    Full Text Available The aim of the study was to test and verify the characteristics of a new type of carbon-coated ARTECOR® vascular prosthesis developed at the Knitting Research Institute, a.s. Brno. Eight healthy Merino sheep, aged between 2 and 3 years, were implanted four types (A, B, C with diamond-like carbon (DLC coating and D as a control without DLC of vascular prostheses. The site of implantation was the common carotid artery; the length of the implant was 7 cm. All sheep received antibiotics prophylactically in accordance with the theory of the so-called “protected coagulum”. Doppler ultrasound examination was performed before finishing the operation to verify the patency of each prosthesis. During the study period the animals were closely observed. Prostheses were extirpated on day +/- 100 in 6 sheep and on day 182 in 2 sheep. Type B prosthesis showed better results according to its postoperative patency. The implant lumen was constantly 7 mm, whereas the use of other types resulted in lumen narrowing. Type B prosthesis has a deposition of DLC coating of a thickness of 20 nm with a high content of sp3 bonds (more diamond-like ones. The experimental type B of prosthesis ARTECOR® appears to be the most successful of the tested prostheses (at the end of the study all B-type prostheses remained patent. This prosthesis appears to better satisfy the rheologic characteristics for healing.

  6. Restoring Proprioception via a Cortical Prosthesis: A Novel Learning-Based Approach

    Science.gov (United States)

    2015-10-01

    AWARD NUMBER: W81XWH-14-1-0510 TITLE: Restoring Proprioception via a Cortical Prosthesis : A Novel Learning-Based Approach PRINCIPAL INVESTIGATOR...Proprioception via a Cortical Prosthesis : A Novel Learning-Based Approach 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Philip Sabes, PhD 5d...component of this lost sensation is proprioception, the feeling of where the body is in space. The importance of proprioception is often not appreciated

  7. Clinical experience with an alloplastic stoma prosthesis (Biocarbon) for urinary conduits and cutaneous ureterostomy.

    Science.gov (United States)

    Månsson, W; Harzmann, R

    1988-01-01

    An alloplastic stoma prosthesis, Biocarbon, composed of 99.9% pure carbon in vitreous form, was used in six patients with conduit urinary diversion and in seven with cutaneous ureterostomy. The patients were thereafter observed for 2-86 months. Complications were subcutaneous infection, urinary fistula and ureteral stenosis, which necessitated removal of the prosthesis in most cases. The permanent stoma, without need for adhesive collecting device, was appreciated by the patients. Problems relating to biocompatibility remain to be solved before the place of the stoma prosthesis in urinary diversion can be determined.

  8. [Psychological assessment of patients who have ++undergone breast reconstruction using 2 different technics: autologous tissue versus prosthesis].

    Science.gov (United States)

    Franchelli, S; Leone, M S; Passarelli, B; Perniciaro, G; Capelli, M; Baracco, G; Alberisio, A; Santi, P L

    1995-05-01

    Breast reconstruction has become an available option for most patients undergoing mastectomy: in fact many authors agree that breast reconstruction does not interfere with possible therapies and improves the quality of life of women. The aim of the study was to evaluate the psychological adjustment of patients who had immediate or delayed reconstruction using 2 different methods: implants and autologous tissues. The study population (115 patients) was derived from patients who underwent breast reconstruction in the period January 1988-December 1991, in follow-up at the Department of Plastic and Reconstructive Surgery; no patient was undergoing psychological therapy. 58 patients underwent breast reconstruction using implants and 57 using Transverse Rectus Abdominis Myocutaneous Flap (TRAMF). Informations were gathered, including the patient's age, the number of offspring, the marital status, the scholastic education, the job and the relapse between mastectomy and reconstruction. The psychological instruments consisted in three standardized self-administered questionnaires: Psychological Distress Inventory (PDI), State Trait Anxiety Inventory form Y (STAI), Eysenk Personality Inventory (EPQ-R). These tests were chosen to gauge the psychological distress, such anxiety, anger, depression and psychosocial maladjustment. To better perform the changes of body image after breast reconstruction, women were requested to answer three more specific questions about the sexual desire, physical image and social relationships. The 102 patients assessed in this study indicate low incidence of psychological distress and adaptive coping strategies. Impairment was reported, regarding body image, by patients undergoing delayed reconstruction; in these patients higher scores in distress tests were observed.

  9. The double capsules in macro-textured breast implants.

    Science.gov (United States)

    Giot, Jean-Philippe; Paek, Laurence S; Nizard, Nathanael; El-Diwany, Mostafa; Gaboury, Louis A; Nelea, Monica; Bou-Merhi, Joseph S; Harris, Patrick G; Danino, Michel A

    2015-10-01

    Breast implants are amongst the most widely used types of permanent implants in modern medicine and have both aesthetic and reconstructive applications with excellent biocompatibility. The double capsule is a complication associated with textured prostheses that leads to implant displacement; however, its etiology has yet to be elucidated. In this study, 10 double capsules were sampled from breast expander implants for in-depth analysis; histologically, the inner capsular layer demonstrated highly organized collagen in sheets with delamination of fibers. At the prosthesis interface (PI) where the implant shell contacts the inner capsular layer, scanning electron microscopy (SEM) revealed a thin layer which mirrored the three-dimensional characteristics of the implant texture; the external surface of the inner capsular layer facing the intercapsular space (ICS) was flat. SEM examination of the inner capsule layer revealed both a large bacterial presence as well as biofilm deposition at the PI; a significantly lower quantity of bacteria and biofilm were found at the ICS interface. These findings suggest that the double capsule phenomenon's etiopathogenesis is of mechanical origin. Delamination of the periprosthetic capsule leads to the creation of the ICS; the maintained separation of the 2 layers subsequently alters the biostability of the macro-textured breast implant. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. A cognitive prosthesis for complex decision-making.

    Science.gov (United States)

    Tremblay, Sébastien; Gagnon, Jean-François; Lafond, Daniel; Hodgetts, Helen M; Doiron, Maxime; Jeuniaux, Patrick P J M H

    2017-01-01

    While simple heuristics can be ecologically rational and effective in naturalistic decision making contexts, complex situations require analytical decision making strategies, hypothesis-testing and learning. Sub-optimal decision strategies - using simplified as opposed to analytic decision rules - have been reported in domains such as healthcare, military operational planning, and government policy making. We investigate the potential of a computational toolkit called "IMAGE" to improve decision-making by developing structural knowledge and increasing understanding of complex situations. IMAGE is tested within the context of a complex military convoy management task through (a) interactive simulations, and (b) visualization and knowledge representation capabilities. We assess the usefulness of two versions of IMAGE (desktop and immersive) compared to a baseline. Results suggest that the prosthesis helped analysts in making better decisions, but failed to increase their structural knowledge about the situation once the cognitive prosthesis is removed. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Imaging of common breast implants and implant-related complications: A pictorial essay

    Directory of Open Access Journals (Sweden)

    Amisha T Shah

    2016-01-01

    Full Text Available The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  12. Stress distribution in dental prosthesis under an occlusal combined dynamic loading

    International Nuclear Information System (INIS)

    Merdji, A.; Bachir Bouiadjra, B.; Ould Chikh, B.; Mootanah, R.; Aminallah, L.; Serier, B.; Muslih, I.M.

    2012-01-01

    Highlights: ► The mechanical stress reaches the highest in areas of cortical bones. ► The mechanical stress in the cancellous bone reaches greatest in the bottom of the dental implant. ► Implant with low-volume bone might cause increased stress concentration in the cortical bone. -- Abstract: The biomechanical behavior of osseointegrated dental prostheses systems plays an important role in its functional longevity inside the bone. Simulation of these systems requires an accurate modeling of the prosthesis components, the jaw bone, the implant–bone interface, and the response of the system to different types of applied forces. The purpose of this study was to develop a new three-dimensional model of an osseointegrated molar dental prosthesis and to carry out finite element analysis to evaluate stress distributions in the bone and the dental prosthesis compounds under an occlusal combined dynamic load was applied to the top of the occlusale face of the prosthesis crown. The jaw bone model containing cortical bone and cancellous bone was constructed by using computer tomography scan pictures and Computer Aided Design tools. The dental prosthesis compounds were constructed, simulating the commercially available cylindrical implant of 4.8 mm diameter and 10 mm length. Both finite element models were created in Abaqus finite element software. All materials used in the models were considered to be isotropic, homogeneous and linearly elastic. The elastic properties, loads and constraints used in the model were taken from published data. Results of our finite element analyses, indicated that the maximum stresses were located around the mesial neck of the implant, in the marginal bone. Thus, this area should be preserved clinically in order to maintain the bone–implant interface structurally and functionally.

  13. A simplified approach to fabrication of an ocular prosthesis: A case series

    Directory of Open Access Journals (Sweden)

    Kaur Amandeep

    2010-01-01

    Full Text Available The eye is a vital organ and an important component of facial expression. Loss of an eye has a crippling effect on the psychology of the patient. Enucleation of the eye is therefore normally followed by fabrication of an ocular prosthesis to improve esthetics. A less complex technique for fabrication of an ocular prosthesis is described in this report of two different cases.

  14. Visual prosthesis wireless energy transfer system optimal modeling.

    Science.gov (United States)

    Li, Xueping; Yang, Yuan; Gao, Yong

    2014-01-16

    Wireless energy transfer system is an effective way to solve the visual prosthesis energy supply problems, theoretical modeling of the system is the prerequisite to do optimal energy transfer system design. On the basis of the ideal model of the wireless energy transfer system, according to visual prosthesis application condition, the system modeling is optimized. During the optimal modeling, taking planar spiral coils as the coupling devices between energy transmitter and receiver, the effect of the parasitic capacitance of the transfer coil is considered, and especially the concept of biological capacitance is proposed to consider the influence of biological tissue on the energy transfer efficiency, resulting in the optimal modeling's more accuracy for the actual application. The simulation data of the optimal model in this paper is compared with that of the previous ideal model, the results show that under high frequency condition, the parasitic capacitance of inductance and biological capacitance considered in the optimal model could have great impact on the wireless energy transfer system. The further comparison with the experimental data verifies the validity and accuracy of the optimal model proposed in this paper. The optimal model proposed in this paper has a higher theoretical guiding significance for the wireless energy transfer system's further research, and provide a more precise model reference for solving the power supply problem in visual prosthesis clinical application.

  15. False-positive indium-111 labeled leukocyte scintigram in a patient with a painful hip prosthesis

    International Nuclear Information System (INIS)

    Feldman, N.; Makler, P.T. Jr.; Alavi, A.

    1986-01-01

    A Tronzo hip prosthesis is designed to elicit an inflammatory reaction in order to promote prosthesis stability. A three-phased bone scan and Ga-67 imaging in conjunction with physical examination and laboratory findings failed to demonstrate evidence for osteomyelitis in a patient with a painful hip prosthesis, in whom images obtained with In-111-labeled leukocytes were positive. This observation demonstrated that the interpretation of the latter technique in demonstrating inflammation can cause a false impression of an infectious process

  16. Nontraumatic Fracture of the Femoral Condylar Prosthesis in a Total Knee Arthroplasty Leading to Mechanical Failure

    Directory of Open Access Journals (Sweden)

    Girish N. Swamy

    2014-01-01

    Full Text Available This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA. A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before.

  17. Nontraumatic fracture of the femoral condylar prosthesis in a total knee arthroplasty leading to mechanical failure.

    Science.gov (United States)

    Swamy, Girish N; Quah, Conal; Bagouri, Elmunzar; Badhe, Nitin P

    2014-01-01

    This paper reports a case of fatigue fracture of the femoral component in a cruciate-retaining cemented total knee arthroplasty (TKA). A 64-year-old man had undergone a primary TKA for osteoarthritis 10 years previously at another institution using the PFC-Sigma prosthesis. The patient recovered fully and was back to his regular activities. He presented with a history of sudden onset pain and locking of the left knee since the preceding three months. There was no history of trauma, and the patient was mobilizing with difficulty using crutches. Radiographs revealed fracture of the posterior condyle of the femoral prosthesis. Revision surgery was performed as an elective procedure revealing the broken prosthesis. The TC3RP-PFC revision prosthesis was used with a medial parapatellar approach. The patient recovered fully without any squeal. Mechanical failure of the knee arthroplasty prosthesis is rare, and nontraumatic fracture of the femoral metallic component has not been reported before.

  18. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    Science.gov (United States)

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  19. Development and performance of a new prosthesis system using ultrasonic sensor for wrist movements: a preliminary study

    Science.gov (United States)

    2014-01-01

    Background The design and performance of a new development prosthesis system known as biomechatronics wrist prosthesis is presented in this paper. The prosthesis system was implemented by replacing the Bowden tension cable of body powered prosthesis system using two ultrasonic sensors, two servo motors and microcontroller inside the prosthesis hand for transradial user. Methods The system components and hand prototypes involve the anthropometry, CAD design and prototyping, biomechatronics engineering together with the prosthetics. The modeler construction of the system develop allows the ultrasonic sensors that are placed on the shoulder to generate the wrist movement of the prosthesis. The kinematics of wrist movement, which are the pronation/supination and flexion/extension were tested using the motion analysis and general motion of human hand were compared. The study also evaluated the require degree of detection for the input of the ultrasonic sensor to generate the wrist movements. Results The values collected by the vicon motion analysis for biomechatronics prosthesis system were reliable to do the common tasks in daily life. The degree of the head needed to bend to give the full input wave was about 45° - 55° of rotation or about 14 cm – 16 cm. The biomechatronics wrist prosthesis gave higher degree of rotation to do the daily tasks but did not achieve the maximum degree of rotation. Conclusion The new development of using sensor and actuator in generating the wrist movements will be interesting for used list in medicine, robotics technology, rehabilitations, prosthetics and orthotics. PMID:24755242

  20. Cancer risk among Danish women with cosmetic breast implants.

    Science.gov (United States)

    Friis, Søren; Hölmich, Lisbet R; McLaughlin, Joseph K; Kjøller, Kim; Fryzek, Jon P; Henriksen, Trine F; Olsen, Jørgen H

    2006-02-15

    The available epidemiologic evidence does not support a carcinogenic effect of silicone breast implants on breast or other cancers. Data on cancer risk other than breast cancer are limited and few studies have assessed cancer risk beyond 10-15 years after breast implantation. We extended follow-up of our earlier cohort study of Danish women with cosmetic breast implants by 7 years, yielding 30 years of follow-up for women with longest implant duration. The study population consisted of women who underwent cosmetic breast implant surgery at private clinics of plastic surgery (n = 1,653) or public hospitals (n = 1,110), and a control group of women who attended private clinics for other plastic surgery (n = 1,736), between 1973-95. Cancer incidence through 2002 was ascertained using the Danish Cancer Registry. Risk evaluation was based on computation of standardized incidence ratios (SIR) and Cox proportional hazards models, adjusting for age, calendar period and reproductive history. We observed 163 cancers among women with breast implants compared to 136.7 expected based on general population rates (SIR = 1.2; 95% confidence interval [CI] = 1.0-1.4), during a mean follow-up period of 14.4 years (range = 0-30 years). Women with breast implants experienced a reduced risk of breast cancer (SIR = 0.7; 95% CI = 0.5-1.0), and an increased risk of non-melanoma skin cancer (SIR = 2.1; 95% CI = 1.5-2.7). Stratification by age at implantation, calendar year at implantation and time since implantation showed no clear trends, however, the statistical precision was limited in these analyses. When excluding non-melanoma skin cancer, the SIR for cancer overall was 1.0 (95% CI = 0.8-1.2). With respect to other site-specific cancers, no significantly increased or decreased SIR were observed. Similar results were found when directly comparing women who had implants at private clinics with women who attended private clinics for other plastic surgery, with rate ratios for cancer

  1. Malignant esophageal stenosis: treatment with the Wallsten ''TM prosthesis

    International Nuclear Information System (INIS)

    Paul, L.; Pinto, I.

    1998-01-01

    To discuss the technical aspects and adders the clinical results of treatment of malignant esophaged dysphagia by placement of a Wallstent prosthesis under fluoroscopic guidance. Over the past six years, we have implanted 63 Wallstent metallic prostheses in 40 patients with un operable malignant dysphagia of esophaged origin. The consisted of 36 men and 6 women with a mean age of 72 years. Seven of the neoplasms were associated with fistula.Six involved recurrent tumors at the point of the surgical anastomosis. Following implantation, the patients were evaluated clinically and radiologically at postoperative hour 48 and periodically thereafter until their death or until the study was completed in September 1996. The placement of the prostheses was achieved in all the patients. Immediate technical problems (malposition or failure to expand) in 27.5% of cases. Forty percent of the patients complained of plain, and there was one death due to massive hematemesis. A clear improvement in dysphagia was obtained was obtained in 79% of and only one of the 7 fistulas was closed. During follow-up, the main complication was obstruction of prosthesis (25%) as a result of tumor overgrowth (9 episodes in 8 patients) or due to food impaction (4 episodes in 3 patients). The rate of retreatment was 27.5%. The mean survival time after prosthesis implantation was 132 ±207 days and 62.5% of the devices were still permeable when the patient died. Implantation of Wallstent prosthesis in cases of malignant esophageal stenosis is easy and safe, and constitutes an effective treatment of dysphagia. Nevertheless, thorough knowledge of the technical aspects ensures better results and the strict assessment of the indications guarantees an improved cost-benefit ratio for this technique. (Author) 23 refs

  2. Iris reconstruction using artificial iris prosthesis for management of aniridia.

    Science.gov (United States)

    Mostafa, Yehia S; Osman, Amr A; Hassanein, Dina H; Zeid, Ashraf M; Sherif, Ahmed M

    2018-01-01

    To discuss the limitations and benefits of the BrightOcular prosthetic artificial iris device in management of aniridia associated with aphakia or cataract. This is a retrospective study including 5 eyes of 4 patients who underwent implantation of the BrightOcular iris prosthesis (Stellar Devices) for total or partial aniridia. The cases included 2 eyes of 1 patient with congenital aniridia associated with congenital cataract and 3 eyes with traumatic aniridia: 1 with subluxated cataractous lens and 2 with aphakia. In all cases, the iris prosthesis was implanted after a 3-piece acrylic intraocular lens was implanted. We evaluated the clinical course with a minimum follow-up period of 6 months, the intraoperative and postoperative complications, and the cosmetic satisfaction of patients. All patients had improved uncorrected distance visual acuity and best-corrected distance visual acuity. All patients had a transient corneal edema that resolved within the first postoperative week. Only the patient with congenital aniridia had a permanent increase in intraocular pressure and developed a band keratopathy throughout a 2-year follow-up period. The prosthesis was well-centered in all eyes except for one case that required scleral suture fixation after 3 months. All patients had a satisfactory cosmetic appearance. BrightOcular iris prosthesis is a safe and useful tool to correct aniridia associated with pseudophakia or aphakia. Being foldable, it is easy to be implanted through a small incision and placed in the ciliary sulcus without sutures when properly sized. Cosmetic results are satisfactory. Sizing methods should be improved.

  3. Early postoperative dislocation of the anterior Maverick lumbar disc prosthesis: report of 2 cases.

    Science.gov (United States)

    Gragnaniello, Cristian; Seex, Kevin A; Eisermann, Lukas G; Claydon, Matthew H; Malham, Gregory M

    2013-08-01

    The authors report on 2 cases of anterior dislocation of the Maverick lumbar disc prosthesis, both occurring in the early postoperative period. These cases developed after experience with more than 50 uneventful cases and were therefore thought to be unrelated to the surgeon's learning curve. No similar complications have been previously reported. The anterior Maverick device has a ball-and-socket design made of cobalt-chromium-molybdenum metal plates covered with hydroxyapatite. The superior and inferior endplates have keels to resist translation forces. The patient in Case 1 was a 52-year-old man with severe L4-5 discogenic pain; and in Case 2, a 42-year-old woman with disabling L4-5 and L5-S1 discogenic back pain. Both patients were without medical comorbidities and were nonsmokers with no risk factors for osteoporosis. Both had undergone uneventful retroperitoneal approaches performed by a vascular access surgeon. Computed tomography studies on postoperative Day 2 confirmed excellent prosthesis placement. Initial recoveries were uneventful. Two weeks postoperatively, after stretching (extension or hyperextension) in bed at home, each patient suffered the sudden onset of severe abdominal pain with anterior dislocation of the Maverick prosthesis. The patients were returned to the operating room and underwent surgery performed by the same spinal and vascular surgeons. Removal of the Maverick prosthesis and anterior interbody fusion with a separate cage and plate were performed. Both patients had recovered well with good clinical and radiological recovery at the 6- and 12-month follow-ups. Possible causes of the anterior dislocation of the Maverick prosthesis include the following: 1) surgeon error: In both cases the keel cuts were neat, and early postoperative CT confirmed good placement of the prosthesis; 2) equipment problem: The keel cuts may have been too large because the cutters were worn, which led to an inadequate press fit of the implants; 3) prosthesis

  4. Fusion around cervical disc prosthesis: case report.

    NARCIS (Netherlands)

    Bartels, R.H.M.A.; Donk, R.

    2005-01-01

    OBJECTIVE AND IMPORTANCE: Cervical arthroplasty is a relatively new method to maintain motion after cervical anterior discectomy. Two cases are presented in which bony fusion occurred around a cervical disc prosthesis. CLINICAL PRESENTATION: A 30-year-old man and a 49-year-old woman underwent a

  5. Heterotopic ossification associated with myelopathy following cervical disc prosthesis implantation.

    Science.gov (United States)

    Wenger, Markus; Markwalder, Thomas-Marc

    2016-04-01

    This case report presents a 37-year-old man with clinical signs of myelopathy almost 9 years after implantation of a Bryan disc prosthesis (Medtronic Sofamor Danek, Memphis, TN, USA) for C5/C6 soft disc herniation. As demonstrated on MRI and CT scan, spinal cord compression was caused by bony spurs due to heterotopic ossification posterior to the still moving prosthesis. The device, as well as the ectopic bone deposits, had to be removed because of myelopathy and its imminent aggravation. Conversion to anterior spondylodesis was performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Short-Term Effect of Prosthesis Transforming Sensory Modalities on Walking in Stroke Patients with Hemiparesis

    Science.gov (United States)

    Sekiguchi, Yusuke; Honda, Keita; Ishiguro, Akio

    2016-01-01

    Sensory impairments caused by neurological or physical disorders hamper kinesthesia, making rehabilitation difficult. In order to overcome this problem, we proposed and developed a novel biofeedback prosthesis called Auditory Foot for transforming sensory modalities, in which the sensor prosthesis transforms plantar sensations to auditory feedback signals. This study investigated the short-term effect of the auditory feedback prosthesis on walking in stroke patients with hemiparesis. To evaluate the effect, we compared four conditions of auditory feedback from plantar sensors at the heel and fifth metatarsal. We found significant differences in the maximum hip extension angle and ankle plantar flexor moment on the affected side during the stance phase, between conditions with and without auditory feedback signals. These results indicate that our sensory prosthesis could enhance walking performance in stroke patients with hemiparesis, resulting in effective short-term rehabilitation. PMID:27547456

  7. Breast imaging using an amorphous silicon-based full-field digital mammographic system: stability of a clinical prototype.

    Science.gov (United States)

    Vedantham, S; Karellas, A; Suryanarayanan, S; D'Orsi, C J; Hendrick, R E

    2000-11-01

    An amorphous silicon-based full-breast imager for digital mammography was evaluated for detector stability over a period of 1 year. This imager uses a structured CsI:TI scintillator coupled to an amorphous silicon layer with a 100-micron pixel pitch and read out by special purpose electronics. The stability of the system was characterized using the following quantifiable metrics: conversion factor (mean number of electrons generated per incident x-ray), presampling modulation transfer function (MTF), detector linearity and sensitivity, detector signal-to-noise ratio (SNR), and American College of Radiology (ACR) accreditation phantom scores. Qualitative metrics such as flat field uniformity, geometric distortion, and Society of Motion Picture and Television Engineers (SMPTE) test pattern image quality were also used to study the stability of the system. Observations made over this 1-year period indicated that the maximum variation from the average of the measurements were less than 0.5% for conversion factor, 3% for presampling MTF over all spatial frequencies, 5% for signal response, linearity and sensitivity, 12% for SNR over seven locations for all 3 target-filter combinations, and 0% for ACR accreditation phantom scores. ACR mammographic accreditation phantom images indicated the ability to resolve 5 fibers, 4 speck groups, and 5 masses at a mean glandular dose of 1.23 mGy. The SMPTE pattern image quality test for the display monitors used for image viewing indicated ability to discern all contrast steps and ability to distinguish line-pair images at the center and corners of the image. No bleeding effects were observed in the image. Flat field uniformity for all 3 target-filter combinations displayed no artifacts such as gridlines, bad detector rows or columns, horizontal or vertical streaks, or bad pixels. Wire mesh screen images indicated uniform resolution and no geometric distortion.

  8. A kinematic assessment of knee prosthesis from fluoroscopy images

    International Nuclear Information System (INIS)

    Hossain, Mohammad Abrar; Fukunaga, Michihiko; Hirokawa, Shunji

    2008-01-01

    We have developed a technique for estimation 3D motion of knee prosthesis from its 2D perspective projections. Our estimation algorithm includes some innovations such as a two-step estimation algorithm, incorporative use of a geometric articulation model and a new method to solve two silhouettes' overlapping problem. Computer model simulations and experiments results demonstrated that our algorithms give sufficient accuracy. Next, with the cooperation of medical surgeons, we assessed the algorithm's clinical performance by applying it to moving fluoroscopy images of patients who had just undergone total knee arthroplasty (TKA) recently. Our experiments were done in four steps; first we have taken the moving X-ray pictures called fluoroscopy images of the knee prosthesis at different knee motions; second, introduced the absolute positions/orientations for both components, third, introduced the relative positions/orientations between the femoral and the tibial components and finally, introduced the contact points trajectories between the femur and the tibial insert. We drew the estimation results graphically and made the computer-aided detection (CAD) model pictures of the prosthesis, thereby helping us to assess how the relative motions between the femoral and the tibial components were generated. Estimation results of the clinical applications demonstrated that our algorithm worked well as like as theoretical. (author)

  9. A new prosthetic alignment device to read and record prosthesis alignment data.

    Science.gov (United States)

    Pirouzi, Gholamhossein; Abu Osman, Noor Azuan; Ali, Sadeeq; Davoodi Makinejad, Majid

    2017-12-01

    Prosthetic alignment is an essential process to rehabilitate patients with amputations. This study presents, for the first time, an invented device to read and record prosthesis alignment data. The digital device consists of seven main parts: the trigger, internal shaft, shell, sensor adjustment button, digital display, sliding shell, and tip. The alignment data were read and recorded by the user or a computer to replicate prosthesis adjustment for future use or examine the sequence of changes in alignment and its effect on the posture of the patient. Alignment data were recorded at the anterior/posterior and medial/lateral positions for five patients. Results show the high level of confidence to record alignment data and replicate adjustments. Therefore, the device helps patients readjust their prosthesis by themselves, or prosthetists to perform adjustment for patients and analyze the effects of malalignment.

  10. Endoscopic palliation of esophageal and cardial cancer: Nd:YAG laser and prosthesis

    Science.gov (United States)

    Norberto, Lorenzo; Ranzato, Riccardo; Marino, Saverio; Angriman, Imerio; Vella, Vincenzo; Donadi, Michele; D'Amico, D. F.

    1997-12-01

    From November 1, 1992 to January 31, 1997, 227 patients with inoperable esophageal and cardial carcinomas were treated with Nd:YAG laser therapy and prosthesis intubation. The retrograde technique was used in most cases. The tumor involved in 75 pts the Cardia, in 65 the middle thoracic esophagus, in 47 pts the lower thoracic esophagus, in 23 in the upper thoracic esophagus and in 17 in the cervical esophagus. The indications for palliative Nd:YAG laser and prosthesis intubation were a locally advanced or metastatic tumor in 146 pts (64.4%) and poor surgical risk in 81 pts (35.6%). The quality of palliation was evaluated according to the ability to swallow. The mean survival rate of the patients during the follow up was 22 weeks for the laser therapy and 16 weeks for the prosthesis intubation.

  11. The influence of prosthesis diameter in stapes surgery: a meta-analysis and systematic review of the literature.

    Science.gov (United States)

    Laske, Roman D; Röösli, Christof; Chatzimichalis, Michail Vasileios; Sim, Jae Hoon; Huber, Alexander M

    2011-06-01

    To analyze the influence of stapes prosthesis diameter on postoperative hearing results after stapedotomy without interposition in otosclerotic patients. PubMed search from 1970 to 2009 using the key words stapedotomy or stapedectomy or otosclerosis or stapesplasty. Inclusion criteria to select articles and patient groups for meta-analysis and statistical analyses were as follows: otosclerosis as diagnosis, clear description of technique and prosthesis size, calibrated stapedotomy, and complete report of functional results. Five controlled studies were found analyzing the influence of prosthesis diameter and reporting the results in a comparable way for meta-analysis (n = 590). Sixty-two studies not analyzing the influence of prosthesis diameter contained comparable subgroups with a total of 9,536 cases. These cases were pooled according to their diameter (0.3, 0.4, 0.5, 0.6,and 0.8 mm). The results of air conduction, bone conduction, air-bone gap (ABG), and success rate (closure of the ABG within 10 dB as percentage of the total cases) for all groups and frequency-specific ABG results were gathered. Furthermore, 12 clinical and experimental studies were reviewed that did not contribute to the statistical analysis. A meta-analysis performed for success rate of the 5 controlled studies showed favorable results for 0.6-mm over 0.4-mm prostheses (success rate, 67% versus 58%, p = 0.05). In the statistical analysis of the pooled data, the 0.6-mm prosthesis showed better results compared with 0.4 mm (p prosthesis in the high frequencies. There was no difference in postoperative change of bone conduction in the 0.6- and 0.4-mm groups. Statistically significant results could not be assessed for other prosthesis diameters because of the small number of cases reported. A 0.6-mm diameter piston prosthesis is associated with significantly better results than a 0.4-mm prosthesis and should be used if the surgical conditions allow it.

  12. Phantom studies of triple photon absorptiometry and bone mineral measurement at a hip prosthesis

    International Nuclear Information System (INIS)

    Farrell, T.J.; Webber, C.E.

    1992-01-01

    The feasibility of using triple photon absorptiometry (TPA) for the measurement of bone mineral mass about a hip prosthesis was examined. A theoretical expression describing the variance of TPA measurements was verified using a triple photon source and phantom materials which simulate the soft tissue-bone mineral-metal prosthesis system. The expression for the variance was used to determine an optimized set of photon energies. It was shown that a precision of 3% could be obtained for reasonable measurement times using this optimized set of energies and that TPA should be a feasible approach for measurement of bone mineral about a hip prosthesis. (orig.)

  13. 21 CFR 888.3360 - Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metallic cemented or... Hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted...

  14. [COMPUTER ASSISTED DESIGN AND ELECTRON BEAMMELTING RAPID PROTOTYPING METAL THREE-DIMENSIONAL PRINTING TECHNOLOGY FOR PREPARATION OF INDIVIDUALIZED FEMORAL PROSTHESIS].

    Science.gov (United States)

    Liu, Hongwei; Weng, Yiping; Zhang, Yunkun; Xu, Nanwei; Tong, Jing; Wang, Caimei

    2015-09-01

    To study the feasibility of preparation of the individualized femoral prosthesis through computer assisted design and electron beammelting rapid prototyping (EBM-RP) metal three-dimensional (3D) printing technology. One adult male left femur specimen was used for scanning with 64-slice spiral CT; tomographic image data were imported into Mimics15.0 software to reconstruct femoral 3D model, then the 3D model of individualized femoral prosthesis was designed through UG8.0 software. Finally the 3D model data were imported into EBM-RP metal 3D printer to print the individualized sleeve. According to the 3D model of individualized prosthesis, customized sleeve was successfully prepared through the EBM-RP metal 3D printing technology, assembled with the standard handle component of SR modular femoral prosthesis to make the individualized femoral prosthesis. Customized femoral prosthesis accurately matching with metaphyseal cavity can be designed through the thin slice CT scanning and computer assisted design technology. Titanium alloy personalized prosthesis with complex 3D shape, pore surface, and good matching with metaphyseal cavity can be manufactured by the technology of EBM-RP metal 3D printing, and the technology has convenient, rapid, and accurate advantages.

  15. Breast implants following mastectomy in women with early-stage breast cancer: prevalence and impact on survival

    International Nuclear Information System (INIS)

    Le, Gem M; O'Malley, Cynthia D; Glaser, Sally L; Lynch, Charles F; Stanford, Janet L; Keegan, Theresa HM; West, Dee W

    2005-01-01

    Few studies have examined the effect of breast implants after mastectomy on long-term survival in breast cancer patients, despite growing public health concern over potential long-term adverse health effects. We analyzed data from the Surveillance, Epidemiology and End Results Breast Implant Surveillance Study conducted in San Francisco–Oakland, in Seattle–Puget Sound, and in Iowa. This population-based, retrospective cohort included women younger than 65 years when diagnosed with early or unstaged first primary breast cancer between 1983 and 1989, treated with mastectomy. The women were followed for a median of 12.4 years (n = 4968). Breast implant usage was validated by medical record review. Cox proportional hazards models were used to estimate hazard rate ratios for survival time until death due to breast cancer or other causes for women with and without breast implants, adjusted for relevant patient and tumor characteristics. Twenty percent of cases received postmastectomy breast implants, with silicone gel-filled implants comprising the most common type. Patients with implants were younger and more likely to have in situ disease than patients not receiving implants. Risks of breast cancer mortality (hazard ratio, 0.54; 95% confidence interval, 0.43–0.67) and nonbreast cancer mortality (hazard ratio, 0.59; 95% confidence interval, 0.41–0.85) were lower in patients with implants than in those patients without implants, following adjustment for age and year of diagnosis, race/ethnicity, stage, tumor grade, histology, and radiation therapy. Implant type did not appear to influence long-term survival. In a large, population-representative sample, breast implants following mastectomy do not appear to confer any survival disadvantage following early-stage breast cancer in women younger than 65 years old

  16. Towards a Completely Implantable, Light-Sensitive Intraocular Retinal Prosthesis

    National Research Council Canada - National Science Library

    Humayun, M

    2001-01-01

    An electronic retinal prosthesis is under development to treat retinitis pigmentosa and age-related macular degeneration, two presently incurable diseases of the outer retina that afflict millions world-wide...

  17. Biomedical and psychosocial factors influencing transtibial prosthesis fit : a Delphi survey among health care professionals

    NARCIS (Netherlands)

    Baars, Erwin C.; Schrier, Ernst; Geertzen, Jan H.; Dijkstra, Pieter U.

    2015-01-01

    Purpose: We aimed to reach consensus among professionals caring for prosthesis users, on definitions of biomedical and psychosocial factors, to assess their influence on fit of transtibial prosthesis and to identify new factors. Method: A three-round, internet-based, Delphi survey was conducted

  18. An innovative and simple approach to fabricate a hollow ocular prosthesis with functional lubricant reservoir: A solution to artificial eye comfort

    Directory of Open Access Journals (Sweden)

    Aditya Anil Kavlekar

    2017-01-01

    Full Text Available The loss of an eye is an emotional and psychological setback to the patient. An ocular prosthesis is created to restore the lost anatomical structure and to correct the cosmetic defect. The tear reflexes do not function at optimal levels in anophthalmic sockets which make prosthesis wear uncomfortable. This case report presents an innovative hollow ocular prosthesis with functional lubricant reservoir which upon normal blinking would draw the lubricant from the reservoir through an exit hole which spreads over the prosthesis allowing a comfortable and long duration of prosthesis wear.

  19. Ipsilateral Fracture Shaft Femur with Neglected Dislocation of Prosthesis: A Case Report

    Directory of Open Access Journals (Sweden)

    Mantu Jain

    2013-10-01

    Full Text Available Introduction: Neglected hip dislocation is rare in today’s world and after prosthesis replacement even rarer finding. However such patients may not report to surgeons until they develop secondary complications. Management of such patient’s is a challenge to the treating surgeon and need to be tailored suiting to patient’s demands, expectations and constraints of financial resources. We did not find a similar case in the electronic and print media and therefore report this case which was innovatively managed. Case Report: A 60 year farmer presented with fracture shaft femur and ipsilateral dislocation prosthesis of right hip. He had a hemiarthroplasty done for fracture neck of femur in the past but used to walk with a lurch since he started to ambulate after discharge. However he was satisfied despite “some problems” which had caused shortening of his limb. The patient was informed of the various treatment options and their possible complications. He expressed his inability to afford a Total Hip Arthroplasty (THA at any stage and consented for other options discussed with him. The patient was positioned supine and adductor tenotomy done. Next he was positioned laterally and the fracture was fixed with heavy duty broad dynamic compression plate and screws. The wound was temporarily closed. Now through the previous scar via posterior approach the hip was exposed. The prosthesis was found to be firmly fixed to the proximal femur. The acetabulum was cleared with fibrous tissue. All attempts the prosthesis to relocate the prosthesis failed after several attempts and it was best decided to leave alone. Post operatively period was uneventful. At follow up he refused for any further manoeuvre in future inform of heavy traction and attempts to reduce the same. At one year when he was walking unaided and his X-rays showed that fracture had well united his SF-36 score was PCS – 49.6 and MCS – 51.9. Conclusion: Ipsilateral shaft femur fracture

  20. Aesthetic breast augmentation with hyaluronic acid: imaging findings and implications for radiological assessment

    Directory of Open Access Journals (Sweden)

    Divanei Aparecida Bottaro Criado

    2012-06-01

    Full Text Available New injectable fillers such as hyaluronic acid have recently been employed as a non-surgical alternative to implants such as silicone for aesthetic breast enhancement. Although their utilization is not yet widespread in Brazil, radiologists should be aware of the imaging findings in this context and of the implications of the presence of this filler for the radiological evaluation in the screening for breast cancer.

  1. Bicentric bipolar hip prosthesis: A radiological study of movement at the interprosthetic joint

    Directory of Open Access Journals (Sweden)

    Anil Kumar Rai

    2011-01-01

    Full Text Available Background: The bipolar hip prostheses after some time functions as a unipolar device. There is a need to change the design of bipolar hip prostheses to make it function as a bipolar device over a prolonged period of time. A bicentric bipolar hip prosthesis was used as an implant for various conditions of the hip. We evaluated the movement of this newly developed prosthesis at the interprosthetic joint radiologically at periodic intervals. Materials and Methods: Fifty two cases were operarted with the Bicentric bipolar prosthesis for indications like fracture neck of femur and various other diseases of the hip and were followed up with serial radiographs at periodic intervals to evaluate, what fraction of the total abduction at the hip was occurring at the interprosthetic joint. Results: In cases of intracapsular fracture neck of femur, the percentage of total abduction occurring at the interprosthetic joint at 3 months follow-up was 33.74% (mean value of all the patients, which fell to 25.66% at 1.5 years. In indications for bipolar hemireplacement other than fracture neck of femur, the percentage of total abduction occurring at the interprosthetic joint at 3 months follow-up was 71.71% (mean value and at 1.5 years it was 67.52%. Conclusion: This study shows the relative preservation of inner bearing movement in the bipolar hip prosthesis with time probably due its refined design. Further refinements are needed to make the prosthesis work better in patients of intracapsular fracture neck femur.

  2. Distant Migration of Multiple Siliconomas in Lower Extremities following Breast Implant Rupture: Case Report.

    Science.gov (United States)

    Oh, Joo Hyun; Song, Seung Yong; Lew, Dae Hyun; Lee, Dong Won

    2016-10-01

    Siliconoma from ruptured breast implants has been reported in multiple body sites, including but not limited to the breast parenchyma, axillary lymph nodes, upper arm, and even lower leg. In this regard, we report a rare case of distant silicone migration to the lower extremities after traumatic breast implant rupture. A 55-year-old Asian woman who received bilateral augmentation mammoplasty 20 years ago presented with ruptured breast implants from a car accident 2 years earlier. Magnetic resonance imaging confirmed intracapsular and extracapsular rupture of the right breast implant, showing "linguine sign." We removed the bilateral breast implants and performed capsulectomy and bilateral reduction mammoplasty using inverted-T incisions. The implant was confirmed as a smooth, silicone gel-filled mammary implant of 125 cm 3 by a Japanese manufacturer, Koken. During her regular follow-up outpatient visits, physical examination revealed 2.5- × 1.5-cm ill-defined, tender, subcutaneous nodules on both knees and 8.5- × 3.0-cm inflammatory changes in the inguinal area with persistent pain. Computed tomography showed no definite mass, but rather infiltrative, nonenhancing soft-tissue densities in the subcutaneous layers of the bilateral inguinal and knee areas. Surgical excision was performed, and pathologic findings confirmed variable vacuoles with foreign body reaction and fibrosis, consistent with siliconoma. It is important to acknowledge that siliconomas can be encountered in patients with ruptured breast implants, especially those manufactured decades ago. Our patient with masses as remote as the inguinal and knee areas is a prime example of how far siliconomas can migrate.

  3. Evidence of echoic memory with a multichannel cochlear prosthesis.

    Science.gov (United States)

    Jerger, S; Watkins, M J

    1988-10-01

    Short-term memory was examined in a subject with a multichannel cochlear prosthesis. Serial recall for lists of digits revealed what are widely regarded as the principal hallmarks of echoic memory, namely the recency effect and the suffix effect. Thus, probability of recall increased for the last one or two digits, except when a nominally irrelevant but spoken item was appended to the to-be-remembered list. It appears, therefore, that a multichannel cochlear implant can give rise to not only the perception of, but also an echoic memory for, speech. As with normal subjects, the suffix effect did not occur with a nonspeech suffix, implying that the echoic memory from the prosthesis shows normal sensitivity to the distinction between speech and nonspeech.

  4. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; Melle, van Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie P. J.; Jongbloed, Monique R. M.; Post, Martijn C.; Sieswerda, Gertjan T.; in 't Veld, Anna Huis; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    Objectives To report the prevalence of aortic valve prosthesis patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis

  5. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease

    NARCIS (Netherlands)

    van Slooten, Ymkje J.; van Melle, Joost P.; Freling, Hendrik G.; Bouma, Berto J.; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C.; Sieswerda, Gertjan T.; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A.; Pieper, Petronella G.

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in

  6. Prosthetic replacement of the medial meniscus in cadaveric knees - Does the prosthesis mimic the functional behavior of the native meniscus?

    NARCIS (Netherlands)

    Tienen, TG; Verdonschot, N; Heijkants, RGJC; Buma, R; Scholten, JGF; van Kampen, A; Veth, RPH

    2004-01-01

    Meniscus replacement by a polymer meniscus prosthesis in dogs resulted in generation of new meniscal tissue. Hypothesis: Optimal functioning of the prosthesis would involve realistic deformation and motion patterns of the prosthesis during knee joint motion. Study Design: Controlled laboratory

  7. The Talar Body Prosthesis: Results at Ten to Thirty-six Years of Follow-up.

    Science.gov (United States)

    Harnroongroj, Thos; Harnroongroj, Thossart

    2014-07-16

    Satisfactory results of implantation of the talar body prosthesis were reported in 1997, although some complications associated with the initial design were noted. The present study evaluated outcomes of treatment with a modified talar body prosthesis. Of the thirty-six talar body prostheses implanted with use of a transmalleolar surgical approach from 1974 to 2011, thirty-three were available for follow-up at ten to thirty-six years or had failed prior to that time. The indication for implantation had been osteonecrosis in twenty-three patients, a comminuted talar fracture in eight, and a talar body tumor in two. Twenty-eight of the thirty-three prostheses were still in place at the time of final follow-up and five had failed prior to five years. The duration of follow-up was ten to twenty years in eight patients, twenty to thirty years in eleven, and thirty to thirty-six years in nine. The AOFAS (American Orthopaedic Foot & Ankle Society) ankle-hindfoot score did not differ significantly among these three groups. Patients over sixty-five years of age with underlying disease that impeded walking ability had lower AOFAS scores. Early prosthesis failure occurred as a result of size mismatch in two patients, tumor recurrence in one, infection in one, and osteonecrosis of the talar head and neck in one. These failures, which occurred at eight to fifty-seven months, were treated with tibiotalar arthrodesis in three patients, prosthesis revision in one, and below-the-knee amputation in one. Although early prosthesis failure may occur, survival of the talar body prosthesis can provide satisfactory ankle and foot function. Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence. Copyright © 2014 by The Journal of Bone and Joint Surgery, Incorporated.

  8. Investigation of the in-vitro loading on an artificial spinal disk prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Kyriacou, P A; Pancholi, M P [School of Engineering and Mathematical Sciences, City University London (United Kingdom); Yeh, J, E-mail: P.Kyriacou@city.ac.u [Department of Neurosurgery, Royal London Hospital, Barts and the London NHS Trust, London (United Kingdom)

    2009-07-01

    Spinal diseases imposes considerable burden to both patients and society. In recent years, much surgical efforts have been made in advancing the treatment of neck and back pain. Of particular prominence is the increasing clinical acceptance and use of intervertebral artificial disk prosthesis for the treatment of discogenic back pain. Despite this increased use of such disks, their in-vivo monitoring remains rudimentary. In an effort to develop an intelligent artificial spinal disk where the in-vivo loading of the spine can by studied for the first time an experimental set up has been created in order to initially study the in-vitro loading on an artificial disc prosthesis. Eight strain gauges and two piezoresistive sensors were used and placed suitably in the artificial disk prosthesis. The results from the in-vitro loading showed linear relationship between loading and the outputs from the sensors with good repeatability and less hysteresis.

  9. Investigation of the in-vitro loading on an artificial spinal disk prosthesis

    International Nuclear Information System (INIS)

    Kyriacou, P A; Pancholi, M P; Yeh, J

    2009-01-01

    Spinal diseases imposes considerable burden to both patients and society. In recent years, much surgical efforts have been made in advancing the treatment of neck and back pain. Of particular prominence is the increasing clinical acceptance and use of intervertebral artificial disk prosthesis for the treatment of discogenic back pain. Despite this increased use of such disks, their in-vivo monitoring remains rudimentary. In an effort to develop an intelligent artificial spinal disk where the in-vivo loading of the spine can by studied for the first time an experimental set up has been created in order to initially study the in-vitro loading on an artificial disc prosthesis. Eight strain gauges and two piezoresistive sensors were used and placed suitably in the artificial disk prosthesis. The results from the in-vitro loading showed linear relationship between loading and the outputs from the sensors with good repeatability and less hysteresis.

  10. Design and Control of a New Biomimetic Transfemoral Knee Prosthesis Using an Echo-Control Scheme

    Directory of Open Access Journals (Sweden)

    Mario G. Bernal-Torres

    2018-01-01

    Full Text Available Passive knee prostheses require a significant amount of additional metabolic energy to carry out a gait cycle, therefore affecting the natural human walk performance. Current active knee prostheses are still limited because they do not reply with accuracy of the natural human knee movement, and the time response is relatively large. This paper presents the design and control of a new biomimetic-controlled transfemoral knee prosthesis based on a polycentric-type mechanism. The aim was to develop a knee prosthesis able to provide additional power and to mimic with accuracy of the natural human knee movement using a stable control strategy. The design of the knee mechanism was obtained from the body-guidance kinematics synthesis based on real human walking patterns obtained from computer vision and 3D reconstruction. A biomechanical evaluation of the synthesized prosthesis was then carried out. For the activation and control of the prosthesis, an echo-control strategy was proposed and developed. In this echo-control strategy, the sound side leg is sensed and synchronized with the activation of the knee prosthesis. An experimental prototype was built and evaluated in a test rig. The results revealed that the prosthetic knee is able to mimic the biomechanics of the human knee.

  11. Design optimization of a breast imaging system based on silicon microstrip detectors

    International Nuclear Information System (INIS)

    Stres, S.; Mikuz, M.

    2000-01-01

    A mammographic imaging set-up using silicon microstrip detectors in edge-on geometry was simulated using the GEANT package. Deposited energy in tissue of various thicknesses was evaluated and shown to agree to within 10% with reference calculations. Optimal energies as well as spectra for mammography with silicon detectors were determined by maximizing the figure of merit of a realistic imaging set-up. The scattered to primary radiation ratio was studied for various detector geometries. It was found that fan-shaped detectors are needed to maintain the image quality for divergent photon beams. (author)

  12. New protocol for construction of eyeglasses-supported provisional nasal prosthesis using CAD/CAM techniques.

    Science.gov (United States)

    Ciocca, Leonardo; Fantini, Massimiliano; De Crescenzio, Francesca; Persiani, Franco; Scotti, Roberto

    2010-01-01

    A new protocol for making an immediate provisional eyeglasses-supported nasal prosthesis is presented that uses laser scanning, computer-aided design/computer-aided manufacturing procedures, and rapid prototyping techniques, reducing time and costs while increasing the quality of the final product. With this protocol, the eyeglasses were digitized, and the relative position of the nasal prosthesis was planned and evaluated in a virtual environment without any try-in appointment. This innovative method saves time, reduces costs, and restores the patient's aesthetic appearance after a disfiguration caused by ablation of the nasal pyramid better than conventional restoration methods. Moreover, the digital model of the designed nasal epithesis can be used to develop a definitive prosthesis anchored to osseointegrated craniofacial implants.

  13. Perivalvular pannus and valve thrombosis: two concurrent mechanisms of mechanical valve prosthesis dysfunction.

    Science.gov (United States)

    Arnáiz-García, María Elena; González-Santos, Jose María; Bueno-Codoñer, María E; López-Rodríguez, Javier; Dalmau-Sorlí, María José; Arévalo-Abascal, Adolfo; Arribas-Jiménez, Antonio; Diego-Nieto, Alejandro; Rodríguez-Collado, Javier; Rodríguez-López, Jose María

    2015-02-01

    A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  14. Sexual Function and Quality of Life Before and After Penile Prosthesis Implantation Following Radial Forearm Flap Phalloplasty.

    Science.gov (United States)

    Young, Ezekiel E; Friedlander, Daniel; Lue, Kathy; Anele, Uzoma A; Khurgin, Jacob L; Bivalacqua, Trinity J; Burnett, Arthur L; Redett, Richard J; Gearhart, John P

    2017-06-01

    To provide sexual function and quality of life outcomes in patients with severe penile deficiency who underwent radial forearm flap phalloplasty with and without penile prosthesis implantation. Patients with history of severe penile deficiency who underwent microsurgical radial forearm flap phalloplasty with and without penile prosthesis implantation between 2007 and 2014 were identified. They completed a set of web-based validated questionnaires including the International Index of Erectile Function, the Pediatric Penile Perception Score, the Sexual Quality of Life for Men, and several items addressing general quality of life. Outcomes were compared between groups. Nine of the 12 identified patients who had prosthesis after phalloplasty and 4 out of the 7 phalloplasty-only patients completed the survey, resulting in an overall response rate of 68%. Among the phalloplasty-prosthesis patients, 66% reported current sexual activity and 78% reported regular masturbation, whereas 1 of the 4 phalloplasty-only patients reported both. Prosthesis patients scored notably higher in all domains of the International Index of Erectile Function except for sexual desire. In contrast, they demonstrated similar scores of penile perception, as well as general and sexual quality of life. Among patients who have undergone flap phalloplasty, the subsequent placement of penile prosthesis appears to effectively allow for both intercourse and masturbation, resulting in measurable improvements in orgasmic function, intercourse satisfaction, and overall sexual satisfaction. Despite these important benefits, prosthesis placement does not appear to result in improvements in penile perception scores, or general or sexual quality of life. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis

    Directory of Open Access Journals (Sweden)

    Feng Hong

    2015-01-01

    Full Text Available Bacterial nanocellulose (BNC has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine.

  16. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis.

    Science.gov (United States)

    Hong, Feng; Wei, Bin; Chen, Lin

    2015-01-01

    Bacterial nanocellulose (BNC) has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine.

  17. Preliminary Study on Biosynthesis of Bacterial Nanocellulose Tubes in a Novel Double-Silicone-Tube Bioreactor for Potential Vascular Prosthesis

    Science.gov (United States)

    Wei, Bin; Chen, Lin

    2015-01-01

    Bacterial nanocellulose (BNC) has demonstrated a tempting prospect for applications in substitute of small blood vessels. However, present technology is inefficient in production and BNC tubes have a layered structure that may bring danger after implanting. Double oxygen-permeable silicone tubes in different diameters were therefore used as a tube-shape mold and also as oxygenated supports to construct a novel bioreactor for production of the tubular BNC materials. Double cannula technology was used to produce tubular BNC via cultivations with Acetobacter xylinum, and Kombucha, a symbiosis of acetic acid bacteria and yeasts. The results indicated that Kombucha gave higher yield and productivity of BNC than A. xylinum. Bacterial nanocellulose was simultaneously synthesized both on the inner surface of the outer silicone tube and on the outer surface of the inner silicone tube. Finally, the nano BNC fibrils from two directions formed a BNC tube with good structural integrity. Scanning electron microscopy inspection showed that the tubular BNC had a multilayer structure in the beginning but finally it disappeared and an intact BNC tube formed. The mechanical properties of BNC tubes were comparable with the reported value in literatures, demonstrating a great potential in vascular implants or in functional substitutes in biomedicine. PMID:26090420

  18. Breast tomography with synchrotron radiation: preliminary results

    International Nuclear Information System (INIS)

    Pani, Silvia; Longo, Renata; Dreossi, Diego; Montanari, Francesco; Olivo, Alessandro; Arfelli, Fulvia; Bergamaschi, Anna; Poropat, Paolo; Rigon, Luigi; Zanconati, Fabrizio; Palma, Ludovico Dalla; Castelli, Edoardo

    2004-01-01

    A system for in vivo breast imaging with monochromatic x-rays has been designed and built at the synchrotron radiation facility Elettra in Trieste (Italy) and will be operational in 2004. The system design involves the possibility of performing both planar mammography and breast tomography. In the present work, the first results obtained with a test set-up for breast tomography are shown and discussed. Tomographic images of in vitro breasts were acquired using monochromatic x-ray beams in the energy range 20-28 keV and a linear array silicon pixel detector. Tomograms were reconstructed using standard filtered backprojection algorithms; the effect of different filters was evaluated. The attenuation coefficients of fibroglandular and adipose tissue were measured, and a quantitative comparison of images acquired at different energies was performed by calculating the differential signal-to-noise ratio of fibroglandular details in adipose tissue. All images required a dose comparable to the dose delivered in clinical, conventional mammography and showed a high resolution of the breast structures without the overlapping effects that limit the visibility of the structures in 2D mammography. A quantitative evaluation of the images proves that the image quality at a given dose increases in the considered energy range and for the considered breast sizes

  19. Complications and Clinical Considerations of the Implant-Retained Zirconia Complete-Arch Prosthesis with Various Opposing Dentitions.

    Science.gov (United States)

    Gonzalez, Jorge; Triplett, Robert G

    To evaluate the performance of the implant-retained zirconia complete-arch prosthesis with various opposing dentitions. The 40 patients included in this retrospective case series study were treated with one or two implant-retained zirconia complete-arch prostheses (ZIRCAP) using the Zirkonzahn protocol. Prettau zirconia frames were created with strategic cutbacks in the structure to extend zirconia incisal coverage of the esthetic anterior sextants and complete monolithic zirconia in the molar areas; subsequent layers of porcelain were applied to nonfunctional and esthetic areas. Patients had three possible occlusal scenarios: (1) maxillary ZIRCAP and mandibular ZIRCAP, (2) maxillary ZIRCAP and mandibular natural dentition, and (3) maxillary ZIRCAP and mandibular conventional hybrid prosthesis. Complications were recorded during follow-up appointments 3, 6, and 12 months after definitive prosthesis delivery. The mean treatment observation period was 33 months. Eight prosthetic complications were noted for the 40 implant-retained zirconia complete-arch prostheses (18.18%), including six cases of minor porcelain chipping and two cases of debonding of the metal insert from the zirconia framework. Maxillary ZIRCAP opposing mandibular ZIRCAP and maxillary ZIRCAP opposing mandibular natural dentition occlusal scenarios presented the same complication ratio of 4. No complications were seen in the maxillary ZIRCAP opposing mandibular conventional hybrid prosthesis group, yet 16 complications were found as denture tooth fractures in 12 mandibular conventional hybrid prostheses (ratio of 0.75). The results indicate that the implant-retained zirconia complete-arch prosthesis offers acceptable performance for use as an alternative to the conventional titanium framework acrylic veneer prosthesis for complete edentulism with a lower incidence of prosthetic complications and fewer maintenance appointments. Chipping of veneering porcelain was the most common complication, but a

  20. Prosthesis-patient mismatch

    Directory of Open Access Journals (Sweden)

    Philippe Pibarot

    2011-04-01

    Full Text Available Prosthesis-patient mismatch (PPM is present when the effective orifice area of the inserted prosthetic valve is too small in relation to body size. Its main hemodynamic consequence is to generate higher than expected gradients through normally functioning prosthetic valves. The purpose of this review is to present an update on the present state of knowledge with regards to diagnosis, prognosis and prevention of PPM. PPM is a frequent occurrence (20%–70% of aortic valve replacements that has been shown to be associated with worse hemodynamics, less regression of left ventricular hypertrophy, more cardiac events, and lower survival. Moreover, as opposed to most other risk factors, PPM can largely be prevented by using a prospective strategy at the time of operation.

  1. Bioelectronic retinal prosthesis

    Science.gov (United States)

    Weiland, James D.

    2016-05-01

    Retinal prosthesis have been translated to clinical use over the past two decades. Currently, two devices have regulatory approval for the treatment of retinitis pigmentosa and one device is in clinical trials for treatment of age-related macular degeneration. These devices provide partial sight restoration and patients use this improved vision in their everyday lives to navigate and to detect large objects. However, significant vision restoration will require both better technology and improved understanding of the interaction between electrical stimulation and the retina. In particular, current retinal prostheses do not provide peripheral visions due to technical and surgical limitations, thus limiting the effectiveness of the treatment. This paper reviews recent results from human implant patients and presents technical approaches for peripheral vision.

  2. Numerical analysis of an osseointegrated prosthesis fixation with reduced bone failure risk and periprosthetic bone loss

    NARCIS (Netherlands)

    Tomaszewski, P. M.; van Diest, M.; Bulstra, S. K.; Verdonschot, N.; Verkerke, G. J.

    2012-01-01

    Currently available implants for direct attachment of prosthesis to the skeletal system after transfemoral amputation (OPRA system. Integrum AB, Sweden and ISP Endo/Exo prosthesis, ESKA Implants AG, Germany) show many advantages over the conventional socket fixation. However, restraining

  3. THR Simulator – the software for generating radiographs of THR prosthesis

    Directory of Open Access Journals (Sweden)

    Hou Sheng-Mou

    2009-01-01

    Full Text Available Abstract Background Measuring the orientation of acetabular cup after total hip arthroplasty is important for prognosis. The verification of these measurement methods will be easier and more feasible if we can synthesize prosthesis radiographs in each simulated condition. One reported method used an expensive mechanical device with an indeterminable precision. We thus develop a program, THR Simulator, to directly synthesize digital radiographs of prostheses for further analysis. Under Windows platform and using Borland C++ Builder programming tool, we developed the THR Simulator. We first built a mathematical model of acetabulum and femoral head. The data of the real dimension of prosthesis was adopted to generate the radiograph of hip prosthesis. Then with the ray tracing algorithm, we calculated the thickness each X-ray beam passed, and then transformed to grey scale by mapping function which was derived by fitting the exponential function from the phantom image. Finally we could generate a simulated radiograph for further analysis. Results Using THR Simulator, the users can incorporate many parameters together for radiograph synthesis. These parameters include thickness, film size, tube distance, film distance, anteversion, abduction, upper wear, medial wear, and posterior wear. These parameters are adequate for any radiographic measurement research. This THR Simulator has been used in two studies, and the errors are within 2° for anteversion and 0.2 mm for wearing measurement. Conclusion We design a program, THR Simulator that can synthesize prosthesis radiographs. Such a program can be applied in future studies for further analysis and validation of measurement of various parameters of pelvis after total hip arthroplasty.

  4. Towards a Completely Implantable, Light-Sensitive Intraocular Retinal Prosthesis

    National Research Council Canada - National Science Library

    Humayun, M

    2001-01-01

    .... Previous studies have established the feasibility of the retinal prosthesis. Short-term tests in blind humans have shown that degenerated retina will respond to light in a way that is consistent with form vision...

  5. [Our experience with the use of Active-C cervical prosthesis].

    Science.gov (United States)

    Misik, Ferenc; Böösi, Martina; Papp, Zoltán; Padányi, Csaba; Banczerowski, Péter

    2016-09-30

    The most widely used surgical procedure in the treatment of cervical spine disc hernias have been the anterior cervical discectomy and fusion for decades. The usage of cervical disc prostheses enabled us to preserve the movements of the affected segments, hereby reducing the overexertion of the adjacent vertebrae and discs. Our goal is to follow our patients operated with Active-C prosthesis (which is used in the Institute since 2010) to gather information about the change of their complaints and about the functioning and unwanted negative effects of the prostheses. Question - Is the usage of Active-C prosthesis an efficient procedure? Between 2010 and 2013, performing the survey of neurological conditions and functional X-ray examinations. We measured the complaints of the patients using the Visual Analogue Scale, Neck Disability Index and Cervical Spine Outcomes Questionnaire. The control group consisted of patients who were operated in one segment using the fusion technique. In the study group according to the Neck Disability Index scale after 18 months, seven patients had no complaints, while twelve persons reported mild and the remaining six moderate complaints. In the control group, moderate complaints were present in four patients, while twelve patients reported mild complaints. The other eight persons showed no complaints. According to the results of the Visual Analogue Scale in the group of prosthesis, the degree of referred pain decreased from 8.6 to 1.84 one and a half years after the surgery. A decrease was observable in the case of axial pain too, from 6.6 down to 1.92 (pcervical disc prosthesis can be considered as an efficient procedure, but at the same time the advantages can only be determined in the long run, therefore further following and studies are required.

  6. Functional property of the cardiac valve prosthesis evaluated in vivo by cine-radiography

    International Nuclear Information System (INIS)

    Murakoshi, Sadaaki

    1986-01-01

    Functional property of the convexo-concave Bjoerk-Shiley cardiac valve prosthesis implanted in the mitral position of 21 patients was investigated by integrated cine-radiography repeated for a long term after operation. The maximum opening angle of the tilting disc was 58 ± 2 deg, and was not affected by atrial fibrillation nor by tachycardia up to 160 bpm. There was no change in the maximum opening angle of the disc observed during follow-up period. Good correlation between shortning of the disc opening time and increase in pulse rate suggests excellent adaptation of this prosthesis for tachycardia induced by exercise or electric pacing. However, atrial fibrillation causes time delay in disc closure immediately after prolonged R-R interval. Disc rotation alleviating disc wear was observed in all the patients whether it moves slow or quick. Dysfunction of the disc opening can be readily determined not only by measuring the maximum disc opening angle, but also by observing the characteristic movement indicated in this study. It is concluded from these results that clinical apprication for the convexo-concave Bjoerk-Shiley valve prosthesis is appropriate and cine-radiography is an useful non-invasive examination of cardiac valve prosthesis for long follow-up period. (author)

  7. Functional property of the cardiac valve prosthesis evaluated in vivo by cine-radiography

    Energy Technology Data Exchange (ETDEWEB)

    Murakoshi, Sadaaki

    1986-07-01

    Functional property of the convexo-concave Bjoerk-Shiley cardiac valve prosthesis implanted in the mitral position of 21 patients was investigated by integrated cine-radiography repeated for a long term after operation. The maximum opening angle of the tilting disc was 58 +- 2 deg, and was not affected by atrial fibrillation nor by tachycardia up to 160 bpm. There was no change in the maximum opening angle of the disc observed during follow-up period. Good correlation between shortning of the disc opening time and increase in pulse rate suggests excellent adaptation of this prosthesis for tachycardia induced by exercise or electric pacing. However, atrial fibrillation causes time delay in disc closure immediately after prolonged R-R interval. Disc rotation alleviating disc wear was observed in all the patients whether it moves slow or quick. Dysfunction of the disc opening can be readily determined not only by measuring the maximum disc opening angle, but also by observing the characteristic movement indicated in this study. It is concluded from these results that clinical apprication for the convexo-concave Bjoerk-Shiley valve prosthesis is appropriate and cine-radiography is an useful non-invasive examination of cardiac valve prosthesis for long follow-up period.

  8. Evaluation of Gait Performance of a Hemipelvectomy Amputation Walking with a Canadian Prosthesis

    Directory of Open Access Journals (Sweden)

    M. T. Karimi

    2014-01-01

    Full Text Available Background. Hemipelvectomy amputation is a surgical procedure in which lower limb and a portion of pelvic are removed. There are a few studies in the literature regarding the performance of subjects with hip disarticulation during walking. However, there is no study on gait analysis of hemipelvectomy subject. Therefore, the aim of this paper was to evaluate the gait and stability of subject with hemipelvectomy amputation. Case Description and Methods. A subject with hemipelvectomy amputation at right side was involved in this study. He used a Canadian prosthesis with single axis ankle joint, 3R21 knee joint, and 7E7 hip joint for more than 10 years. The kinetic and kinematic parameters were collected by a motion analysis system and a Kistler force platform. Findings and Outcomes. There was a significant difference between knee, hip, and ankle range of motions and their moments in the sound and prosthesis sides. In the other side, the stability of the subject in the anteroposterior direction seems to be better than that in the mediolateral direction. Conclusions. There was a significant asymmetry between the kinetic and kinematic performance of the sound and prosthesis sides, which may be due to lack of muscular power and alignment of prosthesis components.

  9. Research and development of a versatile portable speech prosthesis

    Science.gov (United States)

    1981-01-01

    The Versatile Portable Speech Prosthesis (VPSP), a synthetic speech output communication aid for non-speaking people is described. It was intended initially for severely physically limited people with cerebral palsy who are in electric wheelchairs. Hence, it was designed to be placed on a wheelchair and powered from a wheelchair battery. It can easily be separated from the wheelchair. The VPSP is versatile because it is designed to accept any means of single switch, multiple switch, or keyboard control which physically limited people have the ability to use. It is portable because it is mounted on and can go with the electric wheelchair. It is a speech prosthesis, obviously, because it speaks with a synthetic voice for people unable to speak with their own voices. Both hardware and software are described.

  10. Dextran/Albumin hydrogel sealant for Dacron(R) vascular prosthesis.

    Science.gov (United States)

    Lisman, Anna; Butruk, Beata; Wasiak, Iga; Ciach, Tomasz

    2014-05-01

    In this paper, the authors describe a novel type of hydrogel coating prepared from the copolymer of human serum albumin and oxidized dextran. The material was designed as a hydrogel sealant for polyester (Dacron®)-based vascular grafts. Dextran was chosen as a coating material due to its anti-thrombogenic properties. Prepared hydrogels were compared with similar, already known biomaterial made from gelatine with the same cross-linking agent. Obtained hydrogels, prepared from various ratios of oxidized dextran/albumin or oxidized dextran/gelatine, showed different cross-linking densities, which caused differences in swelling, degradation rate and mechanical properties. Permeability tests confirmed the complete tightness of the hydrogel-modified prosthesis. Results showed that application of the hydrogel coating provided leakage-free prosthesis and eliminated the need of pre-clotting.

  11. 21 CFR 888.3358 - Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint metal/polymer/metal semi-constrained... Devices § 888.3358 Hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis. (a) Identification. A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device...

  12. 21 CFR 888.3390 - Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) metal/polymer... § 888.3390 Hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) metal/polymer cemented or uncemented prosthesis is a two-part...

  13. 21 CFR 888.3380 - Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hip joint femoral (hemi-hip) trunnion-bearing... Devices § 888.3380 Hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis. (a) Identification. A hip joint femoral (hemi-hip) trunnion-bearing metal/polyacetal cemented prosthesis is a two...

  14. Prosthetic Rehabilitation of Mandibular Defects with Fixed-removable Partial Denture Prosthesis Using Precision Attachment: A Twin Case Report.

    Science.gov (United States)

    Munot, Vimal Kantilal; Nayakar, Ramesh P; Patil, Raghunath

    2017-01-01

    The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis.

  15. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    Science.gov (United States)

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  16. Complex radial folds versus subtle signs of intracapsular rupture of breast implants: MR findings with surgical correlation.

    Science.gov (United States)

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C D; Georgiade, G S

    1996-06-01

    Detection of intracapsular rupture of silicone breast prostheses using MR imaging is often performed by identifying the "linguine sign" [1]. The linguine sign is easily differentiated from simple radial folds that are seen in intact implants. However, more subtle signs of intracapsular rupture, including undulating subcapsular lines and the "teardrop sign," are less often recognized [2-5] and may prove difficult for the less experienced radiologist to differentiate from complex radial folds of intact implants. In this essay, we illustrate the MR imaging findings of complex radial folds in intact implants and compare them with findings of incomplete shell collapse in ruptured implants in a surgically confirmed series of explanted silicone breast prostheses.

  17. The Influence of Artificial Cervical Disc Prosthesis Height on the Cervical Biomechanics: A Finite Element Study.

    Science.gov (United States)

    Yuan, Wei; Zhang, Haiping; Zhou, Xiaoshu; Wu, Weidong; Zhu, Yue

    2018-05-01

    Artificial cervical disc replacement is expected to maintain normal cervical biomechanics. At present, the effect of the Prestige LP prosthesis height on cervical biomechanics has not been thoroughly studied. This finite element study of the cervical biomechanics aims to predict how the parameters, like range of motion (ROM), adjacent intradiscal pressure, facet joint force, and bone-implant interface stress, are affected by different heights of Prestige LP prostheses. The finite element model of intact cervical spine (C3-C7) was obtained from our previous study, and the model was altered to implant Prestige LP prostheses at the C5-C6 level. The effects of the height of 5, 6, and 7 mm prosthesis replacement on ROM, adjacent intradiscal pressure, facet joint force, as well as the distribution of bone-implant interface stress were examined. ROM, adjacent intradiscal pressure, and facet joint force increased with the prosthesis height, whereas ROM and facet joint force decreased at C5-C6. The maximal stress on the inferior surface of the prostheses was greater than that on the superior surface, and the stresses increased with the prosthesis height. The biomechanical changes were slightly affected by the height of 5 and 6 mm prostheses, but were strongly affected by the 7-mm prosthesis. An appropriate height of the Prestige LP prosthesis can preserve normal ROM, adjacent intradiscal pressure, and facet joint force. Prostheses with a height of ≥2 mm than normal can lead to marked changes in the cervical biomechanics and bone-implant interface stress. Copyright © 2018 Elsevier Inc. All rights reserved.

  18. Finite element analysis of stresses in fixed prosthesis and cement layer using a three-dimensional model

    Directory of Open Access Journals (Sweden)

    Arunachalam Sangeetha

    2012-01-01

    Full Text Available Context: To understand the effect of masticatory and parafunctional forces on the integrity of the prosthesis and the underlying cement layer. Aims: The purpose of this study was to evaluate the stress pattern in the cement layer and the fixed prosthesis, on subjecting a three-dimensional finite element model to simulated occlusal loading. Materials and Methods: Three-dimensional finite element model was simulated to replace missing mandibular first molar with second premolar and second molar as abutments. The model was subjected to a range of occlusal loads (20, 30, 40 MPa in two different directions - vertical and 30° to the vertical. The cements (zinc phosphate, polycarboxylate, glass ionomer, and composite were modeled with two cement thicknesses - 25 and 100 μm. Stresses were determined in certain reference points in fixed prosthesis and the cement layer. Statistical Analysis Used: The stress values are mathematic calculations without variance; hence, statistical analysis is not routinely required. Results: Stress levels were calculated according to Von Mises criteria for each node. Maximum stresses were recorded at the occlusal surface, axio-gingival corners, followed by axial wall. The stresses were greater with lateral load and with 100-μm cement thickness. Results revealed higher stresses for zinc phosphate cement, followed by composites. Conclusions: The thinner cement interfaces favor the success of the prosthesis. The stresses in the prosthesis suggest rounding of axio-gingival corners and a well-established finish line as important factors in maintaining the integrity of the prosthesis.

  19. 21 CFR 874.3695 - Mandibular implant facial prosthesis.

    Science.gov (United States)

    2010-04-01

    ... made of materials such as stainless steel, tantalum, titanium, cobalt-chromium based alloy... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Mandibular implant facial prosthesis. 874.3695... (CONTINUED) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Prosthetic Devices § 874.3695 Mandibular implant...

  20. Biomechanical conceptual design of a passive transfemoral prosthesis.

    NARCIS (Netherlands)

    Ünal, Ramazan; Carloni, Raffaella; Hekman, Edsko E.G.; Stramigioli, Stefano; Koopman, Hubertus F.J.M.

    In this study, we present the conceptual design of a fully-passive transfemoral prosthesis. The proposed design is inspired by the analysis of the musculo-skeletal activity of the healthy human leg. In order to realize an energy efficient device, we introduce three storage elements, which are

  1. Primary anaplastic large cell lymphoma of the breast arising in reconstruction mammoplasty capsule of saline filled breast implant after radical mastectomy for breast cancer: an unusual case presentation

    Directory of Open Access Journals (Sweden)

    Sur Monalisa

    2009-04-01

    Full Text Available Abstract Background Primary non-Hodgkin lymphoma (NHL of the breast represents 0.04–0.5% of malignant lesions of the breast and accounts for 1.7–2.2% of extra-nodal NHL. Most primary cases are of B-cell phenotype and only rare cases are of T-cell phenotype. Anaplastic large cell lymphoma (ALCL is a rare T-cell lymphoma typically seen in children and young adults with the breast being one of the least common locations. There are a total of eleven cases of primary ALCL of the breast described in the literature. Eight of these cases occurred in proximity to breast implants, four in relation to silicone breast implant and three in relation to saline filled breast implant with three out of the eight implant related cases having previous history of breast cancer treated surgically. Adjuvant postoperative chemotherapy is given in only one case. Secondary hematological malignancies after breast cancer chemotherapy have been reported in literature. However in contrast to acute myeloid leukemia (AML, the association between lymphoma and administration of chemotherapy has never been clearly demonstrated. Case Presentation In this report we present a case of primary ALCL of the breast arising in reconstruction mamoplasty capsule of saline filled breast implant after radical mastectomy for infiltrating ductal carcinoma followed by postoperative chemotherapy twelve years ago. Conclusion Primary ALK negative ALCL arising at the site of saline filled breast implant is rare. It is still unclear whether chemotherapy and breast implantation increases risk of secondary hematological malignancies significantly. However, it is important to be aware of these complications and need for careful pathologic examination of tissue removed for implant related complications to make the correct diagnosis for further patient management and treatment. It is important to be aware of this entity at this site as it can be easily misdiagnosed on histologic grounds and to exclude

  2. Autoinflation Leading to Failure of Two-Piece Ambicor Implantable Penile Prosthesis: An Outcome from a Methodical Treatment of Recalcitrant Stuttering Priapism

    Directory of Open Access Journals (Sweden)

    R. Charles Welliver

    2014-01-01

    Full Text Available Introduction. We present the case of a patient who received a two-piece Ambicor penile prosthesis for idiopathic recurrent “stuttering” priapism refractory to other treatment options. The patient returned unable to deflate the device due to an interesting anatomically induced mechanical failure. Aims. To describe the method and findings of this inflatable prosthesis failure. Results. Prosthesis failure occurred due to restrictive corporal diameter and the unique characteristics of fluid reservoir location in the two-piece inflatable prosthesis. The patient was successfully converted to a semirigid prosthesis with resolution of the pain that was due to his prosthesis autoinflation. Conclusion. Stuttering priapism remains a challenging clinical problem. Penile implantation is a reasonable long-term solution in a patient refractory to less invasive options. In patients with fibrotic corpora, a malleable device should be considered (at least temporarily if unable to dilate comfortably to 13 mm.

  3. Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

    International Nuclear Information System (INIS)

    Abdullah, Abdul Halim; Nor, Mohd Asri Mohd; Saman, Alias Mohd; Tamin, Mohd Nasir; Kadir, Mohammed Rafiq Abdul

    2010-01-01

    Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

  4. Breast Implant-Associated Anaplastic Large Cell Lymphoma: Case Report and Review of the Literature.

    Science.gov (United States)

    Berlin, Eva; Singh, Kunwar; Mills, Christopher; Shapira, Ilan; Bakst, Richard L; Chadha, Manjeet

    2018-01-01

    We are reporting the case of a 58-year-old woman with history of bilateral silicone breast implants for cosmetic augmentation. At 2-year interval from receiving the breast implants, she presented with swelling of the right breast with associated chest wall mass, effusion around the implant, and axillary lymphadenopathy. Pathology confirmed breast implant-associated anaplastic large cell lymphoma (stage III, T4N2M0, using BIA-ALCL TNM staging and stage IIAE, using Ann-Arbor staging). The patient underwent bilateral capsulectomy and right partial mastectomy with excision of the right breast mass and received adjuvant CHOP chemotherapy and radiation to the right breast and regional nodes. Since completion of multimodality therapy, the patient has sustained remission on both clinical exam and PET/CT scan. We report this case and review of the literature on this rare form of lymphoma.

  5. Breast implant rupture and connective tissue disease: a review of the literature

    DEFF Research Database (Denmark)

    Hölmich, Lisbet Rosenkrantz; Lipworth, Loren; McLaughlin, Joseph K

    2007-01-01

    Large-scale epidemiologic studies to date have not found any credible association between silicone breast implants and either well-defined connective tissue diseases or undefined or atypical connective tissue diseases. It has been hypothesized that implant rupture could prompt an immunologic reac...

  6. Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model.

    Science.gov (United States)

    Singh, Ipsha; Nair, K Chandrasekharan; Shetty, Jayakar

    2017-01-01

    The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. University of California, Los Angeles, abutment was attached to the implant fixture. Eight strain gauges were attached to the acrylic resin model. Six similar models were made. Implant-supported screw-retained fixed prosthesis was fabricated in nickel-chromium alloy. A load of 400 N was applied on the prosthesis using universal testing machine. Resultant strain was measured in each strain gauge. All the prostheses were sectioned at the area between 36 and 33, 33 and 43, and 43 and 46 using 35 micrometer carborundum disc, and strain was measured in each strain gauge after applying a load of 400 N on the prosthesis. Specimens were joined by arc welding, soldering, and laser welding. After joining, a load of 400 N was applied on each prosthesis and the resultant strain was measured in each strain gauge. Highest mean strain values were recorded before sectioning of the prostheses (889.9 microstrains). Lowest mean strain values were recorded after sectioning the prosthesis and before reuniting it (225.0 microstrains). Sectioning and reuniting the long-span implant prosthesis was found to be a significant factor in influencing the peri-implant strain.

  7. [The esthetics of lower limb prosthesis].

    Science.gov (United States)

    Gardrat, Franck

    2015-01-01

    The amputation, which is upper or lower limb, entails important consequences and often traumatic into subject amputee from a physical, psychological, interpersonal and social point of view. It acts on the body image unleashing different psychological disorders and alterations in the social and professional reality. The aesthetic prosthesis can be considered a good support to help the person regain a new body image of themselves, facilitating the process of physical rehabilitation and social integration.

  8. Impact of removable partial denture prosthesis on chewing efficiency

    Science.gov (United States)

    BESSADET, Marion; NICOLAS, Emmanuel; SOCHAT, Marine; HENNEQUIN, Martine; VEYRUNE, Jean-Luc

    2013-01-01

    Removable partial denture prostheses are still being used for anatomic, medical and economic reasons. However, the impact on chewing parameters is poorly described. Objectives The objective of this study was to estimate the impact of removable partial denture prosthesis on masticatory parameters. Material and Methods Nineteen removable partial denture prosthesis (RPDP) wearers participated in the study. Among them, 10 subjects were Kennedy Class III partially edentulous and 9 with posterior edentulism (Class I). All presented a complete and full dentate opposing arch. The subjects chewed samples of carrots and peanuts with and without their prosthesis. The granulometry of the expectorated boluses from carrot and peanuts was characterized by median particle size (D50), determined at the natural point of swallowing. Number of chewing cycles (CC), chewing time (CT) and chewing frequency (CF=CC/CT) were video recorded. Results With RPDP, the mean D50 values for carrot and peanuts were lower [Repeated Model Procedures (RMP), F=15, p<0.001] regardless of the type of Kennedy Class. For each food, mean CC, CT and CF values recorded decreased (RMP, F=18, F=9, and F=20 respectively, p<0.01). With or without RPD, the boluses' granulometry values were above the masticatory normative index (MNI) determined as 4,000 µm. Conclusion RPDP rehabilitation improves the ability to reduce the bolus particle size, but does not reestablish fully the masticatory function. Clinical relevance This study encourages the clinical improvement of oral rehabilitation procedure. PMID:24212983

  9. Pseudo-capsule “coffin effect”: How to prevent penile retraction after implant of three-piece inflatable prosthesis

    Directory of Open Access Journals (Sweden)

    Enrico Caraceni

    2014-06-01

    Full Text Available Objective: Following three-component implantation of a penile prosthesis, some patients are dissatisfied with their penile length. This may be due to the procedure by itself or pre-existing risk factors or psychological reasons. We supposed that formation of a restricted pseudo-capsule due to a late prosthesis activation can inhibit later system expansion. We aimed to identify the presence or absence of penile retraction after implant and to prevent it by immediate prosthesis activation after implantation. Material and methods. Forty-six patients operated with three-piece inflatable penile prosthesis (AMS 700 CX o LGX were enrolled. In 27 patients prosthesis was first activated four weeks after surgery (NEA group and in 19 patients prosthesis was activated immediately after surgery (DEA group. Length and girth of the penis was evaluated before (in DEA group and after the surgical procedure. Results. The average post implant dorsal length of the erect penis in group NEA was found 3.28 cm shorter than in group with early activation (DEA. In DEA group there was no lenght difference between pre-operative stretching (14.57 cm and post operative erection (14.98 cm. When early activation was not performed, the clinical result was a smaller penis in erect phase. Conclusion. Reduced lenght of the penis after implantation can be caused by the presence of a pseudo-capsule that limits the elongation of the prosthesis and of the penis (“coffin effect”. Timing of first activation seems to be the key in order to prevent the risk of penile retraction after implantation. Early activation is identified as the best measure to maintain the length of the pre implant erect penis after the prosthetic hydraulic implant.

  10. Penile prosthesis implantation in Chinese patients with severe erectile dysfunction: 10-year experience

    Science.gov (United States)

    Song, Wei-Dong; Yuan, Yi-Ming; Cui, Wan-Shou; Wu, Alex K; Zhu, Yi-Chen; Liu, Jing; Wang, Lin; Bai, Guang-Yi; Peng, Jing; Zhang, Zhi-Chao; Gao, Bing; Guo, Ying-Lu; Lue, Tom F; Xin, Zhong-Cheng

    2013-01-01

    We retrospectively evaluated the clinical outcome of penile prosthesis implantation (PPI) in Chinese patients with severe erectile dysfunction (SED). From July 2000 to December 2011, 224 patients (mean age: 35.9±11.8 years, range: 20–75 years) with SED underwent PPI by experienced surgeon according to standard PPI procedure at our centre. A malleable prosthesis (AMS 650) was implanted in 45 cases (20.1%), and a three-piece inflatable prosthesis (AMS 700 CXM or AMS 700 CXR) was implanted in 179 cases (79.9%). Surgical outcomes, including postoperative complications, clinical efficacy and couple satisfaction, were evaluated over than 6 months postoperatively using medical record abstraction, IIEF-5, quality of life (QoL) scores, and the patient/partner sexual satisfaction score proposed by Bhojwani et al. Of the 224 patients eligible for the study, 201 subjects (89.7%) completed follow-up. All of patients could perform sexual intercourse post PPI with the mean postoperative IIEF-5 and QoL scores were 20.02±2.32 and 5.28±0.76, respectively, which were significantly improved compared with the preoperative scores (6.29±1.5 and 2.13±0.84, Preported by 178 men (88.6%), and overall satisfaction with the PPI surgery was reported by 89.0% of men and 82.5% of partners. Patient satisfaction in the three-piece inflatable prosthesis group was higher than in the malleable prosthesis group (P<0.05). Satisfaction, however, between the types of prostheses, did not differ in the partner survey. PPI is a safe and effective treatment option for Chinese patients with SED and experienced surgeon perform PPI according to standard PPI procedure could reduce the postoperative complications of PPI and could improve patient satisfaction ratio and QoL. PMID:23872664

  11. Debridement, antibiotics, irrigation, and retention (DAIR) of the prosthesis after hip hemiarthroplasty infections. Does it work?

    Science.gov (United States)

    Kazimoglu, Cemal; Yalcin, Nadir; Onvural, Burak; Akcay, Serkan; Agus, Haluk

    2015-08-01

    Debridement, antibiotic, and implant retention (DAIR) is an attractive treatment modality after hip hemiarthroplasty (HA) infections. Data about the success of the procedure after acute onset infections is lacking. The aim of this study was to analyze the clinical outcome and associated risk factors. A multicenter, retrospective cohort study was designed, including 39 patients with acute onset prosthetic infection who had undergone debridement and irrigation with prosthesis retention. The primary outcome measure was infection eradication without prosthesis removal. We also analyzed how the success rate was influenced by the length of the interval between implantation of the prosthesis and the beginning of the treatment. The overall success rate was 41%. Sedimentation rate over 60 mm/h and the longer duration (2 weeks) after prosthesis implantation were found as factors negatively influencing the success rate. Our results indicated limited success to DAIR- treated patients with infected HA. The high failure rate of DAIR treatment after 2 weeks from the implantation should be taken into consideration.

  12. Chest-wall reconstruction with a customized titanium-alloy prosthesis fabricated by 3D printing and rapid prototyping.

    Science.gov (United States)

    Wen, Xiaopeng; Gao, Shan; Feng, Jinteng; Li, Shuo; Gao, Rui; Zhang, Guangjian

    2018-01-08

    As 3D printing technology emerge, there is increasing demand for a more customizable implant in the repair of chest-wall bony defects. This article aims to present a custom design and fabrication method for repairing bony defects of the chest wall following tumour resection, which utilizes three-dimensional (3D) printing and rapid-prototyping technology. A 3D model of the bony defect was generated after acquiring helical CT data. A customized prosthesis was then designed using computer-aided design (CAD) and mirroring technology, and fabricated using titanium-alloy powder. The mechanical properties of the printed prosthesis were investigated using ANSYS software. The yield strength of the titanium-alloy prosthesis was 950 ± 14 MPa (mean ± SD), and its ultimate strength was 1005 ± 26 MPa. The 3D finite element analyses revealed that the equivalent stress distribution of each prosthesis was unifrom. The symmetry and reconstruction quality contour of the repaired chest wall was satisfactory. No rejection or infection occurred during the 6-month follow-up period. Chest-wall reconstruction with a customized titanium-alloy prosthesis is a reliable technique for repairing bony defects.

  13. Prosthetic rehabilitation of mandibular defects with fixed-removable partial denture prosthesis using precision attachment: A twin case report

    Directory of Open Access Journals (Sweden)

    Vimal Kantilal Munot

    2017-01-01

    Full Text Available The restoration of normal function and esthetic appearance with a dental prosthesis is a major challenge in the rehabilitation of patients who have lost their teeth and surrounding bone because of surgery for oral cyst or tumor. Rehabilitation with fixed or removable prosthesis is even more challenging when the edentulous span is long and the ridge is defective. Anatomic deformities and unfavorable biomechanics encountered in the region of resection add to the misery. In such situation, a fixed-removable prosthesis allows favorable biomechanical stress distribution along with restoration of esthetics, phonetics, comfort, hygiene, and better postoperative care and maintenance. This article describes rehabilitation of two cases with mandibular defects with an attachment-retained fixed-removable hybrid prosthesis.

  14. And the Breast is History: Issues Surrounding FDA Regulation of Silicone Breast Implants

    OpenAIRE

    Simme, Jodi L.

    1995-01-01

    The breast implant crisis has raised serious issues for women. On one hand, it is difficult to argue against giving women the right to choose, especially when the choice involves their own bodies. Restricting freedom in that realm is politically unpopular these days. On the other hand, women have been harmed by the lack of conclusive health information and by deceptive and coercive messages sent by media, implant manufacturers and plastic surgeons. For women to benefit from their right to cho...

  15. COMPARISON OF CULTURE OF SYNOVIAL FLUID, PERIPROSTHETIC TISSUE AND PROSTHESIS SONICATE FOR THE DIAGNOSIS OF KNEE PROSTHESIS INFECTION

    Directory of Open Access Journals (Sweden)

    Andrej Trampuž

    2003-03-01

    Full Text Available Background. Synovial fluid and periprosthetic tissue specimens are the standard specimens cultured for the diagnosis of prosthetic joint infection (PJI. We hypothesize that ultrasonication of the explanted prosthesis may improve diagnosis of PJI by dislodging biofilm bacteria from the prosthesis surface and improve the sensitivity and specificity of diagnosis of PJI.Methods. Included were patients undergoing knee prosthesis exchange for septic or biomechanical failure and have not received antimicrobial therapy in the last 2 weeks prior specimen collection. Cultures of synovial fluid and periprosthetic tissue specimens were performed per the usual clinical practice. Additionally, explanted joint components were sonicated for 5 minutes at frequency 40 kHz in sterile Ringer’s solution; aliquots of 0.5 ml sonicate were plated onto five aerobic and five anaerobic blood agar plates, and incubated at 37 °C and examined for the next seven days. The number and identity of each colony morphology was recorded.Results. 35 patients undergoing knee replacement have been studied (24 for aseptic biomechanical failure and 11 for suspected PJI. In patients with PJI, coagulase-negative staphylococci (7 cases, Corynebacterium spp. (2 cases, Staphylococcus aureus (1 case, and viridans group streptococcus (1 case were recovered. Culture sensitivity and specificity were for synovial fluid 88% and 100%, for periprosthetic tissue 83% and 81%, and for explant sonicate 91% and 100%, respectively. In sonicate cultures higher numbers of microorganisms than in periprosthetic tissue cultures were consistently detected.Conclusions. Using synovial fluid, periprosthetic tissue, and explant sonicate cultures, 12%, 17% and 9% of PJI were missed, respectively. Explant sonicate cultures were the most sensitive with respect to the diagnosis of PJI, indicating that explant ultrasonication may improve bacterial recovery. In sonicate cultures, infecting organisms were detected in

  16. The clinical relevance of advanced artificial feedback in the control of a multi-functional myoelectric prosthesis.

    Science.gov (United States)

    Markovic, Marko; Schweisfurth, Meike A; Engels, Leonard F; Bentz, Tashina; Wüstefeld, Daniela; Farina, Dario; Dosen, Strahinja

    2018-03-27

    To effectively replace the human hand, a prosthesis should seamlessly respond to user intentions but also convey sensory information back to the user. Restoration of sensory feedback is rated highly by the prosthesis users, and feedback is critical for grasping in able-bodied subjects. Nonetheless, the benefits of feedback in prosthetics are still debated. The lack of consensus is likely due to the complex nature of sensory feedback during prosthesis control, so that its effectiveness depends on multiple factors (e.g., task complexity, user learning). We evaluated the impact of these factors with a longitudinal assessment in six amputee subjects, using a clinical setup (socket, embedded control) and a range of tasks (box and blocks, block turn, clothespin and cups relocation). To provide feedback, we have proposed a novel vibrotactile stimulation scheme capable of transmitting multiple variables from a multifunction prosthesis. The subjects wore a bracelet with four by two uniformly placed vibro-tactors providing information on contact, prosthesis state (active function), and grasping force. The subjects also completed a questionnaire for the subjective evaluation of the feedback. The tests demonstrated that feedback was beneficial only in the complex tasks (block turn, clothespin and cups relocation), and that the training had an important, task-dependent impact. In the clothespin relocation and block turn tasks, training allowed the subjects to establish successful feedforward control, and therefore, the feedback became redundant. In the cups relocation task, however, the subjects needed some training to learn how to properly exploit the feedback. The subjective evaluation of the feedback was consistently positive, regardless of the objective benefits. These results underline the multifaceted nature of closed-loop prosthesis control as, depending on the context, the same feedback interface can have different impact on performance. Finally, even if the closed

  17. The Use of CAD/CAM Trial Pattern for Facial Prosthesis Fabrication of a Maxillofacial Patient with Large Defect

    Directory of Open Access Journals (Sweden)

    Nina Ariani

    2017-12-01

    Full Text Available Treatment of maxillofacial patients needs a multidisciplinary approach of several expertise based on the complexityof the case. Prosthodontists often work together with e.g. ENT, oral or plastic surgeons to provide patient with betterprosthesis and optimum treatment. Case report: A 55 years old male was referred to Dental Teaching Hospital ofUniversitas Indonesia for facial prosthesis fabrication. Patient had undergone squamous cell carcinoma ablationsurgery that encompassed nose, cheek, sinuses, upper lip and most of the hard palate. Due to the extensive natureof the defect, Department of Prosthodontics collaborated with Department of Biomedical Engineering to employ3D printing technique using general purpose machine for fabricating the trial pattern for the prosthesis, withattention given especially to margin areas and facial contours. This technique helps for prosthesis fabrication ofthis patient because manual wax carving is no longer necessary. Wax carving usually is a labor/skill intensive stepand takes longer time. Conclusion: 3D printing of the trial pattern for the prosthesis help minimizes the labor/skill intensive part of facial prosthesis fabrication.

  18. Quantitating the effect of prosthesis design on femoral remodeling using high-resolution region-free densitometric analysis (DXA-RFA)

    DEFF Research Database (Denmark)

    Farzi, Mohsen; Morris, Richard M; Penny, Jeannette

    2017-01-01

    Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs are not ......Dual energy X-ray absorptiometry (DXA) is the reference standard method used to study bone mineral density (BMD) after total hip arthroplasty (THA). However, the subtle, spatially complex changes in bone mass due to strain-adaptive bone remodeling relevant to different prosthesis designs...... using scans acquired during two previous randomized clinical trials (2004 to 2009); one comparing three cemented prosthesis design geometries, and the other comparing a hip resurfacing versus a conventional cementless prosthesis. DXA RFA resolved subtle differences in magnitude and area of bone...... remodeling between prosthesis designs not previously identified in conventional DXA analyses. A mean bone loss of 10.3%, 12.1%, and 11.1% occurred for the three cemented prostheses within a bone area fraction of 14.8%, 14.4%, and 6.2%, mostly within the lesser trochanter (p 

  19. Cell cloning-on-the-spot by using an attachable silicone cylinder.

    Science.gov (United States)

    Park, Hong Bum; Son, Wonseok; Chae, Dong Han; Lee, Jisu; Kim, Il-Woung; Yang, Woomi; Sung, Jae Kyu; Lim, Kyu; Lee, Jun Hee; Kim, Kyung-Hee; Park, Jong-Il

    2016-06-10

    Cell cloning is a laboratory routine to isolate and keep particular properties of cultured cells. Transfected or other genetically modified cells can be selected by the traditional microbiological cloning. In addition, common laboratory cell lines are prone to genotypic drift during their continual culture, so that supplementary cloning steps are often required to maintain correct lineage phenotypes. Here, we designed a silicone-made attachable cloning cylinder, which facilitated an easy and bona fide cloning of interested cells. This silicone cylinder was easy to make, showed competent stickiness to laboratory plastics including culture dishes, and hence enabled secure isolation and culture for days of selected single cells, especially, on the spots of preceding cell-plating dishes under microscopic examination of visible cellular phenotypes. We tested the silicone cylinder in the monoclonal subcloning from a heterogeneous population of a breast cancer cell line, MDA-MB-231, and readily established independent MDA-MB-231 subclones showing different sublineage phenotypes. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Cross-cultural validation of the Prosthesis Evaluation Questionnaire in vascular amputees fitted with prostheses in Spain.

    Science.gov (United States)

    Benavent, Jose Vicente; Igual, Celedonia; Mora, Enrique; Antonio, Rosa; Tenias, Jose Maria

    2016-12-01

    The lack of specific prosthetic-related outcome instruments for Spanish amputees must be addressed. To elaborate a culturally equivalent version of the Prosthesis Evaluation Questionnaire in the Spanish language. Cross-cultural questionnaire validation. Two-step process for cultural adaptation: forward and backward translations of English original and Spanish translated versions; assessment of both construct and criterion validity and reliability in a group of vascular amputees. A total of 61 patients were recruited, 44 men (72.1%) and 17 women (27.9%), with a median age of 71.1 years (standard deviation: 7.7 years; range: 51-87 years). In the Prosthesis Evaluation Questionnaire-Spanish, the lowest scores were for gait and frustration, and the highest scores were for noise and stump health. Internal consistency of the questionnaire was acceptable (>0.70) for four of the scales used in the Prosthesis Evaluation Questionnaire but poor (<0.50) for the scales relating to appearance and stump health. Correlations with the quality-of-life levels as measured by the Short Form-36 were positive and mostly significant. Prosthesis Evaluation Questionnaire-Spanish could assess the quality of life in patients who have undergone vascular amputations and then been fitted with a prosthetic limb. The questionnaire shows adequate criteria validity when compared with other instruments for measuring quality of life. The Prosthesis Evaluation Questionnaire-Spanish could be a valid and reliable instrument for assessing adaptation to prostheses in vascular amputees. The questionnaire adds information relevant to the patient and the physician and may identify cases with poor expected adaptation to the prosthesis. © The International Society for Prosthetics and Orthotics 2015.

  1. Design of a Fully-Passive Transfemoral Prosthesis Prototype

    NARCIS (Netherlands)

    Behrens, Sebastiaan Maria; Behrens, S.M.; Ünal, Ramazan; Unal, R.; Hekman, Edsko E.G.; Carloni, Raffaella; Stramigioli, Stefano; Koopman, Hubertus F.J.M.

    In this study, we present the mechanical design of a prototype of a fully-passive transfemoral prosthesis for normal walking. The conceptual working principle at the basis of the design is inspired by the power flow in human gait, with the main purpose of realizing an energy efficient device. The

  2. Effect of joining the sectioned implant-supported prosthesis on the peri-implant strain generated in simulated mandibular model

    Directory of Open Access Journals (Sweden)

    Ipsha Singh

    2017-01-01

    Full Text Available Aim: The aim of this study is to evaluate the strain developed in simulated mandibular model before and after the joining of an implant-supported screw-retained prosthesis by different joining techniques, namely, arc welding, laser welding, and soldering. Materials and Methods: A specimen simulating a mandibular edentulous ridge was fabricated in heat-cured acrylic resin. 4-mm holes were drilled in the following tooth positions; 36, 33, 43, 46. Implant analogs were placed in the holes. University of California, Los Angeles, abutment was attached to the implant fixture. Eight strain gauges were attached to the acrylic resin model. Six similar models were made. Implant-supported screw-retained fixed prosthesis was fabricated in nickel-chromium alloy. A load of 400 N was applied on the prosthesis using universal testing machine. Resultant strain was measured in each strain gauge. All the prostheses were sectioned at the area between 36 and 33, 33 and 43, and 43 and 46 using 35 micrometer carborundum disc, and strain was measured in each strain gauge after applying a load of 400 N on the prosthesis. Specimens were joined by arc welding, soldering, and laser welding. After joining, a load of 400 N was applied on each prosthesis and the resultant strain was measured in each strain gauge. Results: Highest mean strain values were recorded before sectioning of the prostheses (889.9 microstrains. Lowest mean strain values were recorded after sectioning the prosthesis and before reuniting it (225.0 microstrains. Conclusions: Sectioning and reuniting the long-span implant prosthesis was found to be a significant factor in influencing the peri-implant strain.

  3. To Compare the Effect of Pre and Post Weight Bearing Anxiety, Depression in Conventional and Modular Prosthesis on Unilateral Transtibial Amputees

    Directory of Open Access Journals (Sweden)

    R. Raja

    2014-01-01

    Full Text Available Aims and Objectives: To compare the effect of anxiety and depression on unilateral trans tibial amputees those who are using conventional and modular patellar tendon bearing (PTB prosthesis with stump exercises. Material and Methods: A sample of 40 persons with below knee amputation who were trained to wear prosthesis were studied with an experimental comparative study design. Patients who were admitted at Kempegowda Institute of Medical Sciences and Research Centre, Bangalore, K. S. Hegde Medical Academy and Research Centre Mangalore, (N=150 who underwent unilateral transtibial, transfemoral and other amputations between August 2009 - December 2011. To find out peri and postoperative prosthetic fitting, anxiety and depression level of transtibial amputees who wear conventional and modular PTB prosthesis. 3 years of experimental comparative study reveals that the outcome measures of peri and post-operative anxiety and depression level while using conventional PTB prosthesis with stump exercises and modular PTB prosthesis with stump exercises on unilateral transtibial amputees. Results: The unilateral transtibial amputees who were trained with modular prosthesis along with stump exercises group patients anxiety and depression levels are reduced as compared to the unilateral transtibial amputees who were trained with conventional PTB prosthesis along with stump exercises. There is no significant difference seen in both the groups while giving stump exercises alone. Conclusion: The unilateral transtibial amputees who were trained with modular prosthesis along with stump exercises group, patient’s anxiety and depression levels are reduced drastically.

  4. Treatment of sharp mandibular alveolar process with hybrid prosthesis

    Directory of Open Access Journals (Sweden)

    Sukaedi Sukaedi

    2010-09-01

    Full Text Available Background: Losing posterior teeth for a long time would occasionally lead to the sharpening of alveolar process. The removable partial denture usually have problems when used during mastication, because of the pressure on the mucosa under the alveolar ridge. Purpose: The purpose of this case report was to manage patients with sharp mandibular alveolar process by wearing hybrid prosthesis with extra coronal precision attachment retention and soft liner on the surface base beneath the removable partial denture. Case: A 76 years old woman visited the Prosthodontic Clinic Faculty of Dentistry Airlangga University. The patient had a long span bridge on the upper jaw and a free end acrylic removable partial denture on the lower jaw. She was having problems with mastication. The patient did not wear her lower denture because of the discomfort with it during mastication. Hence, she would like to replace it with a new removable partial denture. Case management: The patient was treated by wearing a hybrid prosthesis with extra coronal precision attachment on the lower jaw. Soft liner was applied on the surface of the removable partial denture. Hybrid prosthesis is a complex denture consisting of removable partial denture and fixed bridge. Conclusion: It concluded that after restoration, the patient had no problems with sharp alveolar process with her new denture, and she was able to masticate well.Latar belakang: Kehilangan geligi posterior dapat menimbulkan processus alveolaris tajam. Gigi tiruan sebagian lepasan mempunyai masalah selama pengunyahan karena adanya tekanan di mukosa di bawah alveolar ridge. Tujuan: Tujuan laporan kasus ini adalah untuk menjelaskan cara menangani pasien yang mempunyai prosesus alveolaris yang tajam di rahang bawah dengan dibuatkan protesis hybrid dengan daya tahan extra coronal precision attachment dan soft liner di permukaan bawah basis gigi tiruan sebagian lepasan. Kasus: Pasien wanita berumur 76 tahun datang di klinik

  5. Removable dental prosthesis as periodontal treatment method

    Directory of Open Access Journals (Sweden)

    Aprilia Adenan

    2007-11-01

    Full Text Available The objectives of prostheses are to restore mastication force, improve esthetics and maintain gingival health. The construction and function of prosthesis restoration are mutually interdependent with condition of periodontal tissues. A properly constructed prosthesis is an integral phase of complete treatment of periodontal disease in order to maintain periodontal tissues health. This paper reports case of a man aged 47 years who came to Dental Specialist Clinic in Oral and Dental Hospital Faculty of Dentistry Universitas Padjadjaran with chief complaint of mobility in almost all his teeth and they seems to look longer. The patient has no systemic disease and did not want his teeth to be extracted. Clinical and panoramic radiographic and laboratoris examinations has been done. During treatment, oclusal adjustment and splinting had been done on tooth 33,34,35 and tooth 44,43 also tooth 43,42 splinting with composite. The following treatment was the acrylic removable partial denture for upper jaw while mandible was fitted a frame denture which functioned as a semi permanent splint. One month post treatment, patien felt comfort and the denture was well functioning.

  6. Eight-year follow-up data from the U.S. clinical trial for Sientra's FDA-approved round and shaped implants with high-strength cohesive silicone gel.

    Science.gov (United States)

    Stevens, W Grant; Harrington, Jennifer; Alizadeh, Kaveh; Broadway, David; Zeidler, Kamakshi; Godinez, Tess B

    2015-05-01

    On March 9, 2012, the Food and Drug Administration (FDA) approved Sientra's premarket approval application for its portfolio of silicone gel breast implants based on their review of Sientra's 3-year study data from the largest pivotal silicone gel breast implant study to date. This included the first approval of shaped breast implants in the United States. The authors provide an update to the 8-year safety and effectiveness of the Sientra High-Strength silicone gel breast implants. The Sientra Core study is an ongoing 10 year open-label, prospective, multi-center clinical study, which includes 1788 patients implanted with 3506 Sientra implants across four indications (Primary Augmentation, Revision Augmentation, Primary Reconstruction, and Revision Reconstruction). For the safety analysis, the incidence of post-operative complications, including all breast implant-related adverse effects (eg, infection, asymmetry), was estimated based on Kaplan-Meier risk rates. The effectiveness analyses include surgeon and patient satisfaction and changes in bra/cup size. Through 8 years, the overall risk of rupture was 4.6%, the risk of capsular contracture was 11.8% (rates were lower when using True Texture™), and the risk of reoperation was 28.3%. Out of the 580 reoperations in 456 patients, over half of all reoperations were due to cosmetic reasons (n = 299). The most common reasons for reoperation were capsular contracture (19.0%), style and/or size change (18.4%), and asymmetry (8.8%). Patient satisfaction remains high through 8 years, with 87% indicating that their breast implants make them feel more feminine than prior to enrollment. Safety data from the FDA Core study continues to support a comprehensive safety and effectiveness profile of Sientra's portfolio of round and shaped implants through 8 years. 3 Therapeutic. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  7. Excessive strut wear allowing ball-poppet embolization in a DeBakey-Surgitool aortic valve prosthesis.

    Science.gov (United States)

    Sutherland, R D; Guynes, W A; Nichols, C T; Martinez, H E

    1982-01-01

    Excessive cage strut wear allowing ball-poppet embolization caused the sudden death of a 47 year old lady in whom a DeBakey-Surgitool aortic prosthesis had been implanted nine years earlier. Patients with this type of prosthesis should have periodic valvular cine fluoroscopy with image intensification to allow visualization of significant strut wear or fracture, and appropriate prosthetic valve replacement.

  8. Extended long term functional outcome of inflatable penile prosthesis in a single institution.

    LENUS (Irish Health Repository)

    Thomas, A Z

    2011-02-01

    We sought to evaluate the extended long term functional outcome of the AMS700 three piece inflatable prosthesis in men with erectile dysfunction in a single urological department and assess our revision rates. Patients that underwent first-time insertion or revision of an AMS700 3 piece inflatable penile prosthesis between 1984-2007 were included. Data was obtained from medical records and long term follow up of patients was conducted by telephone interview. The medical records of 38 patients were available for review. Of these 38 men, 56 prostheses were inserted. The mean follow up was 8.4 years (101 months). The revision rate at 50 months postoperatively was 7\\/38 (18%). The overall revision rate was 18\\/38 (47%). The mean time to revision in these 18 patients was 72 months (12-156 months) after initial insertion of AMS700 penile prosthesis. This study highlights that with longer follow u revision rates markedly increase after 72 months.

  9. Breast Implant-Associated Anaplastic Large Cell Lymphoma: Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Eva Berlin

    2018-01-01

    Full Text Available We are reporting the case of a 58-year-old woman with history of bilateral silicone breast implants for cosmetic augmentation. At 2-year interval from receiving the breast implants, she presented with swelling of the right breast with associated chest wall mass, effusion around the implant, and axillary lymphadenopathy. Pathology confirmed breast implant-associated anaplastic large cell lymphoma (stage III, T4N2M0, using BIA-ALCL TNM staging and stage IIAE, using Ann-Arbor staging. The patient underwent bilateral capsulectomy and right partial mastectomy with excision of the right breast mass and received adjuvant CHOP chemotherapy and radiation to the right breast and regional nodes. Since completion of multimodality therapy, the patient has sustained remission on both clinical exam and PET/CT scan. We report this case and review of the literature on this rare form of lymphoma.

  10. Modified cementless total coxofemoral prosthesis: development, implantation and clinical evaluation

    Directory of Open Access Journals (Sweden)

    S.A. Arias

    2013-12-01

    Full Text Available The aim of this study was to modify canine coxofemoral prostheses and the clinical evaluation of the implantation. Fifteen canine hips and femora of cadavers were used in order to study the surface points of modification in prostheses and develop a perforation guide. Femoral stems and acetabular components were perforated and coated with biphasic calcium phosphate layer. Twelve young adult male mongrel dogs were implanted with coxofemoral prostheses. Six were operated upon and implanted with cemented canine modular hip prostheses, establishing the control group. The remaining six were implanted with a novel design of cementless porous tricalcic phosphate-hydroxyapatite coated hip prostheses. Clinical and orthopedic performance, complications, and thigh muscular hypotrophy were assessed up to the 120th post-operatory day. After 120 days, animals with cementless prostheses had similar clinical and orthopedic performance compared to the cemented group despite the increased pain thigh hypotrophy. Animals that underwent cementless hip prosthesis evidenced more pain, compared to animals with cemented hip prosthesis that required longer recuperation time. No luxations, two fractures and two isquiatic neurapraxies were identified in the course of the study. Using both the cemented and the bioactive coated cementless model were suitable to dogs, showing clinical satisfactory results. Osseointegration and biological fixation were observed in the animals with the modified cementless hip prosthesis.

  11. Reconstruction of chronic acromioclavicular joint disruption with artificial ligament prosthesis

    Directory of Open Access Journals (Sweden)

    Chouhan Devendra Kumar

    2013-08-01

    Full Text Available 【Abstract】Objective: Management of Rockwood type 3 acromioclavicular disruptions is a matter of debate. Should we adopt conservative or operative measures at first presentation? It is not clear but most of the evidences are in favour of conservative management. We present our expe-rience in managing these patients surgically. Methods: We present a prospective series of eight cases of chronic Rockwood type 3 acromioclavicular joint disruptions treated surgically. Anatomical reconstruction of the coracoclavicular ligament was done by artificial braided polyester ligament prosthesis. Results: All the patients were able to perform daily activities from an average of the 14th postoperative day. All patients felt an improvement in pain, with decrease in ave-rage visual analogue scale from preoperative 6.5 points (range 3-9 points to 2.0 points (range 0-5 points, Constant score from 59% to 91% and American Shoulder and Elbow Surgeons shoulder score from 65 to 93 points postoperatively. These results improved or at least remained stationary on midterm follow-up, and no deterioration was recorded at an average follow-up of 46 months. Conclusion: This midterm outcome analysis of the artificial ligament prosthesis is the first such follow-up study with prosthesis. Our results are encouraging and justify the further use and evaluation of this relatively new and easily reproducible technique. Key words: Acromioclavicular joint; Prostheses and implants; Reconstructive surgical procedures; Ligaments

  12. Task-Oriented Gaming for Transfer to Prosthesis Use

    NARCIS (Netherlands)

    van Dijk, Ludger; Sluis, van der Corry K.; van Dijk, Hylke W.; Bongers, Raoul M.

    2016-01-01

    The aim of this study is to establish the effect of task-oriented video gaming on using a myoelectric prosthesis in a basic activity of daily life (ADL). Forty-one able-bodied right-handed participants were randomly assigned to one of four groups. In three of these groups the participants trained to

  13. [Medial unicompartmental knee prosthesis for patients with unicompartmental gonarthrosis

    NARCIS (Netherlands)

    Kort, N.P.; Deutman, R.; Raay, J.J. van; Horn, J.R. van

    2004-01-01

    The function and survival time of unicompartmental knee prostheses for patients with severe gonarthrosis have been improved the past few years by developments in their design, the instrumentarium and the surgical technique. A medial unicompartmental knee prosthesis may be indicated in patients with

  14. Survey on the Contemporary Management of Intraoperative Urethral Injuries During Penile Prosthesis Implantation.

    Science.gov (United States)

    Sexton, Stephanie J; Granieri, Michael A; Lentz, Aaron C

    2018-04-01

    Intraoperative urethral injury is an uncommon event during the placement of a penile prosthesis, and alternative management strategies have been proposed with continuation of implantation after urethral injury. To evaluate surgeon practices in the management of intraoperative urethral injury. An online survey was sent to the society listservs of the Genitourinary Reconstructive Surgeons (GURS) and the Sexual Medicine Society of North America (SMSNA). Physicians were queried on their fellowship training, experience with penile prosthesis implantation, and management of urethral injuries during prosthesis placement. The response data were analyzed using SAS 9.4 (SAS Institute, Cary, NC, USA). The χ 2 test and Fisher exact test were used to determine associations between variables. Survey responses. 131 survey responses were analyzed. Of the responders, 41.2% were GURS fellowship trained, 19.1% were SMSNA trained, 30.5% were non-fellowship trained, and 9.2% were trained in other fellowships. 25.4% of participants performed more than 50 implantations per year, 37.7% performed 20 to 50 per year, and 36.9% performed fewer than 20 per year. Urethral injury during prosthesis implantation was uncommon, with 26.2% reporting 0 injury, 58.5% reporting 1 to 3 injuries, and 15.4% reporting more than 3 career injuries. Injuries were most commonly encountered during corporal dilation (71.1%) compared with corporal exposure (12.5%) or penile straightening maneuvers (7.0%). There was no statistically significant difference with aborting or continuing implantation among GURS-trained, SMSNA-trained, other fellowship-trained, and non-fellowship-trained surgeons. Of all responders, 55% would abort the procedure after distal urethral injury, whereas 45% would continue the procedure with unilateral or bilateral insertion of cylinders. Patient factors that increased likelihood of terminating the procedure in the case of urethral injury included immunosuppression, spinal cord injury, and

  15. Modified prosthesis for the treatment of malignant esophagotracheal fistula

    International Nuclear Information System (INIS)

    Buess, G.; Schellong, H.; Kometz, B.; Gruessner, R.J.; Junginger, T.

    1988-01-01

    Esophagotracheal fistula is usually a sequela of irradiation or laser treatment of advanced carcinoma of the esophagus or the tracheobronchial tree. Resection of the tumor in these cases is not possible, and palliative bypass surgery is highly risky. The peroral placement of a prosthesis is less invasive, but conventional prostheses often fail to occlude the fistula. The authors regularly use an endoscopic multiple-diameter bougie for dilation. After dilation, a specially designed prosthesis is pushed through the tumor stenosis to block the fistula. This procedure can be done without general anesthesia. The funnels of conventional prostheses cannot cover the fistula when there is either a wide, proximal esophagus above the fistula or a high fistula. To cope with this particular situation, a special fistula funnel was developed. It perfectly occludes the fistulas in all patients. Of 21 patients, 19 were discharged without further aspiration

  16. Narrowing beam-walking is a clinically feasible approach for assessing balance ability in lower-limb prosthesis users.

    Science.gov (United States)

    Sawers, Andrew; Hafner, Brian J

    2018-05-08

    Challenging clinical balance tests are needed to expose balance deficits in lower-limb prost-hesis users. This study examined whether narrowing beam-walking could overcome conceptual and practical limitations identified in fixed-width beam-walking. Cross-sectional. Unilateral lower-limb prosthesis users. Participants walked 10 times along a low, narrowing beam. Performance was quantified using the normalized distance walked. Heuristic rules were applied to determine whether the narrowing beam task was "too easy," "too hard," or "appropriately challenging" for each participant. Linear regression and Bland-Altman plots were used to determine whether combinations of the first 5 trials could predict participants' stable beam-walking performance. Forty unilateral lower-limb prosthesis users participated. Narrowing beam-walking was appropriately challenging for 98% of participants. Performance stabilized for 93% of participants within 5 trials, while 62% were stable across all trials. The mean of trials 3-5 accurately predicted stable performance. A clinical narrowing beam-walking test is likely to challenge a range of lower-limb prosthesis users, have minimal administrative burden, and exhibit no floor or ceiling effects. Narrowing beam-walking is therefore a clinically viable method to evaluate lower-limb prosthesis users' balance ability, but requires psychometric testing before it is used to assess fall risk.

  17. The effects of indwelling voice prosthesis on the quality of life, depressive symptoms, and self-esteem in patients with total laryngectomy.

    Science.gov (United States)

    Polat, Beldan; Orhan, Kadir Serkan; Kesimli, Mustafa Caner; Gorgulu, Yasemin; Ulusan, Murat; Deger, Kemal

    2015-11-01

    This study aims to evaluate the effects of voice rehabilitation with indwelling voice prosthesis on quality of life, depression, anxiety, self-esteem, and sexual functions in laryngectomy patients. Provox-1 was applied to 30 patients who underwent total laryngectomy by opening a tracheoesophageal fistula. WHO Quality of Life-BREF, Beck Depression Inventory, Beck Anxiety Inventory, Rosenberg Self-Esteem Scale, Arizona Sexual Experience Scale forms were asked to be filled out by the patients before voice prosthesis application. These tests were asked to be filled out again 3 months later after the voice prosthesis application. Paired samples and Wilcoxon tests were used to compare before and after operation values. Indwelling voice prosthesis was found to improve quality of life, self-esteem, and sexual function (p < 0.05). Additionally, symptoms of depression and anxiety were regressed (p < 0.05). Indwelling voice prosthesis was found to especially increase the quality of life and decrease depression (p < 0.05). This study is an uncontrolled single-arm study comparing patients' psychosocial statuses pre- and post-voice prosthesis.

  18. TOTAL ANKLE ARTHROPLASTY: BRAZILIAN EXPERIENCE WITH THE HINTEGRA PROSTHESIS.

    Science.gov (United States)

    Nery, Caio; Fernandes, Túlio Diniz; Réssio, Cibele; Fuchs, Mauro Luiz; Godoy Santos, Alexandre Leme de; Ortiz, Rafael Trevisan

    2010-01-01

    Ankle arthrosis is becoming more and more common. The search for solutions that preserve joint function has led to a new generation of prosthesis with three components and more degrees of freedom. This paper presents the results achieved for ten patients treated with the HINTEGRA Prosthesis (Integra, New Deal), through collaborative action between the Foot and Ankle Groups of the Orthopedics and Traumatology divisions of Escola Paulista de Medicina, Unifesp, and the School of Medicine of the University of São Paulo (USP). The ten patients (six women and four men, aged between 29 and 66 years), underwent a surgical procedure consisting of Hintermann's technique, between January and June 2005. They were evaluated at prearranged intervals, and the data were subjected to statistical analysis. The surgery led to a significant improvement in ankle mobility. Radiological evaluation showed no signs of loosening or failure in the prosthetic components in any of the patients studied. Although the complication rate in our sample was high, it was equivalent to the rates found by other authors, and directly represents the learning curve associate with this kind of procedure. Four years after the procedure, it was found that the patients pain levels had significantly decreased, and that their functional patterns had significantly improved, with AOFAS and Hintermann scores indicating results that were excellent for 20%, good for 70% and poor for 10%. Treatment of ankle arthritis by means of total arthroplasty using the HINTEGRA prosthesis was capable of providing good results over an average observation period of four years.

  19. [Questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis].

    Science.gov (United States)

    Nicodemo, Denise; Ferreira, Lydia Masako

    2006-01-01

    The patient with anophthalmia may present feelings of inferiority and rejection. Knowing his/her needs and expectations contribute to a better technical intervention. To elaborate a questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis. An exploratory research was used to elaborate the questionnaire, by means of a guided interview followed by writing down what was said by the interviewees, who were adult patients of the Bucco-Maxillo-Facial Prosthesis Center of FOSJC - UNESP. The guided interview was made up of 14 items directly related to the future outline of the profile. Each item of the interview resulted in questions of the questionnaire, which was pretested twice before reaching its final version. The patients reported, in the exploratory research, unpleasant feelings with the loss of the eye; relationship shyness; expectations regarding surgery and prosthesis use; a wish to receive explanations and to hold their opinion about the treatment. The questionnaire of the psychosocial profile of the patient with anophthalmia with indication of ocular prosthesis is, therefore, made of 43 questions divided into 5 blocks in order to aid the comprehension of the inquired aspects and to facilitate both the computation of data and discussion, and also to improve the selection of questions according to the objective of the researcher or professional. It was concluded that the questionnaire was viable, can be used in full or by selecting blocks and provide a panorama of the patient's history related to the problem he/she faces, from the loss of the ocular globe to the confection of the prosthesis.

  20. Maxillary Implant-Supported Fixed Prosthesis: A Survey of Reviews and Key Variables for Treatment Planning.

    Science.gov (United States)

    Gallucci, German O; Avrampou, Marianna; Taylor, James C; Elpers, Julie; Thalji, Ghadeer; Cooper, Lyndon F

    2016-01-01

    This review was conducted to provide information to support the establishment of clinical guidelines for the treatment of maxillary edentulism using implant-supported fixed dental prostheses. Initial efforts were directed toward a systematic review with a defined PICO question: "For maxillary edentulous patients with dental implants treated using a fixed prosthesis, what is the impact of prosthesis design on prosthesis survival and complications?" Following a title search of more than 3,000 titles identified by electronic search of PubMed, 180 articles were identified that addressed the clinical evaluation of maxillary dental implant prostheses. The broad methodologic heterogeneity and clinical variation among reports precluded this approach for a systematic review. The information was extracted using a standardized extraction table by two pairs of investigators, and the reported outcomes were then summarized according to reported outcomes for implant prostheses supported by four, six, or eight implants using unitary or segmented prostheses. This review indicated that high prosthetic survival is observed using all approaches. The advantages of using fewer implants and a unitary prosthesis are revealed in the surgical phases, and complications commonly involve the fracture or detachment of acrylic teeth and reduced access for proper oral hygiene and related biologic complications. Using six implants typically involved grafting of posterior regions with advantages of reduced cantilevers and redundancy of implant support. Reduced prosthesis survival in these cases was associated with poor implant distribution. Segmented prostheses supported by six or more implants offered greater prosthetic survival, perhaps due to posterior implant placement. Advantages of a segmented prosthesis included pragmatic issues of accommodating divergent implants, attaining passive fit, combining prosthetic materials, and relative simplicity of repair. The existing literature demonstrated

  1. HyPro: A Multi-DoF Hybrid-Powered Transradial Robotic Prosthesis

    Directory of Open Access Journals (Sweden)

    C. L. Semasinghe

    2018-01-01

    Full Text Available This paper proposes a multi-DoF hybrid-powered transradial robotic prosthesis, named HyPro. The HyPro consists of two prosthetic units: hand and wrist that can achieve five grasping patterns such as power grasp, tip grasp, lateral grasp, hook grasp, and index point. It is an underactuated device with 15 degrees of freedom. A hybrid powering concept is proposed and implemented on hand unit of HyPro where the key focus is on restoration of grasp functions of biological hand. A novel underactuated mechanism is introduced to achieve the required hand preshaping for a given grasping pattern using electric power in the pregrasp stage and body power is used in grasp stage to execute the final grasping action with the selected fingers. Unlike existing hybrid prostheses where each of the joints is separately controlled by either electric or body power, the proposed prosthesis is capable of delivering grasping power in combination. The wrist unit of HyPro is designed and developed to achieve flexion-extension and supination-pronation using electric power. Experiments were carried out to evaluate the functionality and performance of the proposed hybrid-powered robotic prosthesis. The results verified the potential of HyPro to perform intended grasping patterns effectively and efficiently.

  2. Frequent complications and severe bone loss associated with the repiphysis expandable distal femoral prosthesis.

    Science.gov (United States)

    Cipriano, Cara A; Gruzinova, Irina S; Frank, Rachel M; Gitelis, Steven; Virkus, Walter W

    2015-03-01

    The treatment of choice for distal femur malignancies in skeletally immature patients remains controversial. An expandable endoprosthesis device (Repiphysis Limb Salvage System; Wright Medical Technology, Arlington, TN, USA) allows for limb preservation and noninvasive lengthening but has been associated with significant complications; however, the extent and implications of bone loss associated with this implant have not been reported. Our goals were to report (1) the 2-year minimum clinical outcomes after placement of the Repiphysis expandable prosthesis for pediatric distal femur malignancies; (2) the complications associated with this prosthesis; (3) the failure rate of this prosthesis; and (4) the revision alternatives available for salvage procedures. Between 2002 and 2010, one surgeon (SG) treated all skeletally immature patients (mean age, 10.1 years; range, 4.7-13.6 years) with distal femoral osteosarcoma using a Repiphysis expandable prosthesis. Of the 12 patients who met these criteria, two were excluded for death from disease before 2 years, and mean followup for the remaining 10 was 72 months (range, 26-119 months). Medical records were retrospectively reviewed for complications and clinical outcomes, as assessed by the Musculoskeletal Tumor Society (MSTS) scoring system. Radiographs at final followup were reviewed for bone loss and analyzed by the two senior authors (SG, WWV) to determine reconstruction options available for future revisions. MSTS scores averaged 67%, and we observed 37 implant-related complications requiring a total of 15 reoperations. Six patients underwent implant revisions with aseptic loosening being the predominant mode of failure; ultimately, four of these were converted to adult modular oncology prostheses, and two underwent total femoral replacements. Bone loss in this series was severe in terms of femoral length, cortical thinning, and metadiaphyseal compromise, and most patients will not have sufficient bone stock to permit

  3. An anthropomorphic transhumeral prosthesis socket developed based on an oscillometric pump and controlled by force-sensitive resistor pressure signals.

    Science.gov (United States)

    Razak, N A Abd; Gholizadeh, H; Hasnan, N; Osman, N A Abu; Fadzil, S S Mohd; Hashim, N A

    2017-02-01

    While considering the importance of the interface between amputees and prosthesis sockets, we study an anthropomorphic prosthesis socket whose size can be dynamically changed according to the requirements of the residual limb. First, we introduce the structure and function of the anthropomorphic prosthesis socket. Second, we study the dynamic model of the prosthesis system and analyze the dynamic characteristics of the prosthesis socket system, the inputs of an oscillometric pump, and the control mechanism of force-sensitive resistor (FSR) pressure signals. Experiments on 10 healthy subjects using the designed system yield an average detection result between 102 and 112 kPa for the FSR pressure sensor and 39 and 41 kPa for the oscillometric pump. Results show the function of the FSR pressure signal in maintaining the contact pressure between the sockets and the residual limb. The potential development of an auto-adjusted socket that uses an oscillometric pump system will provide prosthetic sockets with controllable contact pressure at the residual limb. Moreover, this development is an attractive research area for researchers involved in rehabilitation engineering, prosthetics, and orthotics.

  4. Extended Resection of Chest Wall Tumors with Reconstruction Using Poly Methyl Methacrylate-Mesh Prosthesis

    International Nuclear Information System (INIS)

    Abo Sedira, M.; Nassar, O.; Al-Ariny, A.

    2003-01-01

    This prospective study evaluates the early result of patients with massive chest wall tumors treated by extended resection and reconstruction using Prolene or Marlex mesh-enforced with Poly Methyl Methacrylate Bone Cement (PMMC) prosthesis. Material and Methods: This surgery was performed on 40 patients with a mean age of 45±18 (12-62) at the Department of Surgery, National Cancer Institute, Cairo University between 1998-2001. Primary chest wall tumors were the indications of surgery in 42.5%, while secondary involvement extending from other sites principally breast cancer were the indications for 57.5%. In 85% of patients more than 3 ribs were involved by tumors and lesions were more than 10 cm in the greatest dimension in 50% of cases. Resection involved sternum in 15 (37.5%) cases and in 45% of cases complete extensive rib resections extended between costovertebral junctions and the costochondral junctions were performed. Additional resections of nearby organs were needed in 20 (50%) of cases including partial lung resection in 14 cases, partial vertebral resection in 3 cases and diaphragm resection for 3 cases. Immediate bony reconstruction by inserting Prolene or Marlex mesh-enforced with Poly Methyl Methacrylate Bone Cement (PMMC) prosthesis to the resulting chest wall defect was performed in 36 cases, whereas, 4 cases had delayed reconstruction. Primary simple soft tissue closure was sufficient for 37.5% of patients; whereas 35% were covered by local rotational flap and 27.5% needed myocutaneous flaps. No patient with this immediate reconstruction needed ventilatory support or tracheostomy and flail chest was not noticed ICU stay was markedly reduced; whereas 85% required less than 7 days. Immediate post operative (40 days) complications were found in 14 patients (35%) and cases with additional lung resection had more complication rate than others (64% vs 19%). Infection occurred in 3 patients and conservative treatment for 3-4 weeks using frequent

  5. Infectious complications in implant based breast surgery and implications for plastic surgeons [Infektiöse Komplikationen bei alloplastischen Brustoperationen und Implikationen für Plastische Chirurgen

    Directory of Open Access Journals (Sweden)

    Horch, Raymund E.

    2013-07-01

    Full Text Available [english] Implantation of breast prosthesis is still one of the most frequently performed breast reconstructing or contouring procedures. Infectious complications and capsular contracture are inherent problems that may have different causes which are not clearly defined yet in terms of pathophysiology. Recent findings showed bacterial contamination as a major cause of implant failure. Since this has direct implications for the surgical management we report on biofilm development on alloplastic breast prostheses, characteristics and effects after implantation of medical devices in general. This article gives a review of the current literature and discusses possible issues to solve the problem of infection after implantation of breast prosthesis. In conclusion the reinsertion of single-use devices should not be recommended and should be strictly avoided when a device related infection has occured. According to current knowledge contaminated implants should be removed, the infection then be cured and if necessary, a new prosthesis may be implanted after a regeneration period. Alternatively a change in therapy towards autologous tissue reconstruction should be considered if previous attempts with alloplastic prostheses have failed and if radiation therapy has worsened the local tissue situation in the recipient area.[german] Implantationen von Brust-Prothesen sind für Brustrekonstruktionen oder Konturierungen noch immer die am häufigsten durchgeführten Verfahren. Typische inhärente Probleme sind dabei neben infektiösen Komplikationen die Kapselkontrakturen, deren unterschiedliche Ursachen bezüglich der Pathophysiologie noch nicht eindeutig geklärt sind.Neuere Erkenntnisse weisen auf bakterielle Kontamination als eine der Hauptursachen von Implantatversagen hin. Da dies direkte Auswirkungen auf die chirurgische Behandlung hat, berichten wir über das Problem der Biofilmentwicklung auf alloplastischen Brustimplantaten sowie über deren Effekte

  6. Validation of the Narrowing Beam Walking Test in Lower Limb Prosthesis Users.

    Science.gov (United States)

    Sawers, Andrew; Hafner, Brian

    2018-04-11

    To evaluate the content, construct, and discriminant validity of the Narrowing Beam Walking Test (NBWT), a performance-based balance test for lower limb prosthesis users. Cross-sectional study. Research laboratory and prosthetics clinic. Unilateral transtibial and transfemoral prosthesis users (N=40). Not applicable. Content validity was examined by quantifying the percentage of participants receiving maximum or minimum scores (ie, ceiling and floor effects). Convergent construct validity was examined using correlations between participants' NBWT scores and scores or times on existing clinical balance tests regularly administered to lower limb prosthesis users. Known-groups construct validity was examined by comparing NBWT scores between groups of participants with different fall histories, amputation levels, amputation etiologies, and functional levels. Discriminant validity was evaluated by analyzing the area under each test's receiver operating characteristic (ROC) curve. No minimum or maximum scores were recorded on the NBWT. NBWT scores demonstrated strong correlations (ρ=.70‒.85) with scores/times on performance-based balance tests (timed Up and Go test, Four Square Step Test, and Berg Balance Scale) and a moderate correlation (ρ=.49) with the self-report Activities-specific Balance Confidence scale. NBWT performance was significantly lower among participants with a history of falls (P=.003), transfemoral amputation (P=.011), and a lower mobility level (P.50 (ie, chance). The results provide strong evidence of content, construct, and discriminant validity for the NBWT as a performance-based test of balance ability. The evidence supports its use to assess balance impairments and fall risk in unilateral transtibial and transfemoral prosthesis users. Copyright © 2018 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  7. Simulation of the filtration mechanism of hyaluronic acid in total knee prosthesis

    International Nuclear Information System (INIS)

    Paolo, J Di; Berli, M E; Campana, D M; Ubal, S; Cardenes, L D

    2007-01-01

    Polyethylene (UHMWPE) wear in current knee prosthesis causes prosthesis loosening after no more than 15 years. In this work, a steady state one-dimensional lubrication model with non- Newtonian fluid, porous elastic layer on tibial component, ultra-filtration mechanism of fluid and some features of the surface roughness is studied through a numerical technique based on the Finite Element Method. The results show that the UHMWPE stiffness makes difficult the lubrication mechanism of the artificial joint and promotes abrasive and fatigue wear. Nevertheless, the use of compliant porous materials on the tibial component could reduce friction and wear. Moreover, the ultra-filtration mechanism promotes efficiency on the joint

  8. Narrowing beam-walking is a clinically feasible approach for assessing balance ability in lower-limb prosthesis users

    Directory of Open Access Journals (Sweden)

    Andrew Sawers

    2018-03-01

    Full Text Available Objective: Challenging clinical balance tests are needed to expose balance deficits in lower-limb prost-hesis users. This study examined whether narrowing beam-walking could overcome conceptual and practical limitations identified in fixed-width beam-walking. Design: Cross-sectional. Participants: Unilateral lower-limb prosthesis users. Methods: Participants walked 10 times along a low, narrowing beam. Performance was quantified using the normalized distance walked. Heuristic rules were applied to determine whether the narrowing beam task was “too easy,” “too hard,” or “appropriately challenging” for each participant. Linear regression and Bland-Altman plots were used to determine whether combinations of the first 5 trials could predict participants’ stable beam-walking performance. Results: Forty unilateral lower-limb prosthesis users participated. Narrowing beam-walking was appropriately challenging for 98% of participants. Performance stabilized for 93% of participants within 5 trials, while 62% were stable across all trials. The mean of trials 3–5 accurately predicted stable performance. Conclusion: A clinical narrowing beam-walking test is likely to challenge a range of lower-limb prosthesis users, have minimal administrative burden, and exhibit no floor or ceiling effects. Narrowing beam-walking is therefore a clinically viable method to evaluate lower-limb prosthesis users’ balance ability, but requires psychometric testing before it is used to assess fall risk.

  9. New Language and Old Problems in Breast Cancer Radiotherapy.

    Science.gov (United States)

    Chiricuţă, Ion Christian

    2017-01-01

    New developments in breast cancer radiotherapy make possible new standards in treatment recommandations based on international guidelines. Developments in radiotherapy irradiation techniques from 2D to 3D-Conformal RT and to IMRT (Intensity Modulated Arc Therapy) make possible to reduce the usual side effects on the organs at risk as: skin, lung, miocard, bone, esophagus and brahial plexus. Dispite of all these progresses acute and late side effects are present. Side effects are as old as the radiotherapy was used. New solutions are available now by improving irradiation techniques. New techniques as sentinel node procedure (SNP) or partial breast irradiation (PBRT) and immediate breast reconstruction with silicon implants (IBRIS) make necessary new considerations regarding the target volume delineations. A new language for definition of gross tumor volume (GTV), clinical target volume (CTV) based on the new diagnostic methods as PET/CT,nonaparticle MRI will have real impact on target delineation and irradiation techniques. "The new common language in breast cancer therapy" would be the first step to improve the endresults and finally the quality of life of the patients. Celsius.

  10. Inflatable penile prosthesis implant length with baseline characteristic correlations: preliminary analysis of the PROPPER study.

    Science.gov (United States)

    Bennett, Nelson; Henry, Gerard; Karpman, Edward; Brant, William; Jones, LeRoy; Khera, Mohit; Kohler, Tobias; Christine, Brian; Rhee, Eugene; Kansas, Bryan; Bella, Anthony J

    2017-12-01

    "Prospective Registry of Outcomes with Penile Prosthesis for Erectile Restoration" (PROPPER) is a large, multi-institutional, prospective clinical study to collect, analyze, and report real-world outcomes for men implanted with penile prosthetic devices. We prospectively correlated co-morbid conditions and demographic data with implanted penile prosthesis size to enable clinicians to better predict implanted penis size following penile implantation. We present many new data points for the first time in the literature and postulate that radical prostatectomy (RP) is negatively correlated with penile corporal length. Patient demographics, medical history, baseline characteristics and surgical details were compiled prospectively. Pearson correlation coefficient was generated for the correlation between demographic, etiology of ED, duration of ED, co-morbid conditions, pre-operative penile length (flaccid and stretched) and length of implanted penile prosthesis. Multivariate analysis was performed to define predictors of implanted prosthesis length. From June 2011 to June 2017, 1,135 men underwent primary implantation of penile prosthesis at a total of 11 study sites. Malleable (Spectra), 2-piece Ambicor, and 3-piece AMS 700 CX/LGX were included in the analysis. The most common patient comorbidities were CV disease (26.1%), DM (11.1%), and PD (12.4%). Primary etiology of ED: RP (27.4%), DM (20.3%), CVD (18.0%), PD (10.3%), and Priapism (1.4%), others (22.6%). Mean duration of ED is 6.2¡À4.1 years. Implant length was weakly negatively correlated with White/Caucasian (r=-0.18; Pprosthesis length is negatively correlated with some ethnic groups, prostatectomy, and incontinence. Positive correlates include CV disease, preoperative stretched penile length, and flaccid penile length.

  11. Aortic valve prosthesis-patient mismatch and exercise capacity in adult patients with congenital heart disease.

    Science.gov (United States)

    van Slooten, Ymkje J; van Melle, Joost P; Freling, Hendrik G; Bouma, Berto J; van Dijk, Arie Pj; Jongbloed, Monique Rm; Post, Martijn C; Sieswerda, Gertjan T; Huis In 't Veld, Anna; Ebels, Tjark; Voors, Adriaan A; Pieper, Petronella G

    2016-01-01

    To report the prevalence of aortic valve prosthesis-patient mismatch (PPM) in an adult population with congenital heart disease (CHD) and its impact on exercise capacity. Adults with congenital heart disease (ACHD) with a history of aortic valve replacement may outgrow their prosthesis later in life. However, the prevalence and clinical consequences of aortic PPM in ACHD are presently unknown. From the national Dutch Congenital Corvitia (CONCOR) registry, we identified 207 ACHD with an aortic valve prosthesis for this cross-sectional cohort study. Severe PPM was defined as an indexed effective orifice area ≤0.65 cm2/m2 and moderate PPM as an indexed orifice area ≤0.85 cm2/m2 measured using echocardiography. Exercise capacity was reported as percentage of predicted exercise capacity (PPEC). Of the 207 patients, 68% was male, 71% had a mechanical prosthesis and mean age at inclusion was 43.9 years ±11.4. The prevalence of PPM was 42%, comprising 23% severe PPM and 19% moderate PPM. Prevalence of PPM was higher in patients with mechanical prostheses (pHeart Association (NYHA) class remained stable in most patients. PPM showed no significant effect on death or hospitalisation during follow-up (p=0.218). In this study we report a high prevalence (42%) of PPM in ACHD with an aortic valve prosthesis and an independent association of PPM with diminished exercise capacity. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  12. Cyclooxygenase-2 inhibitors and knee prosthesis surgery

    OpenAIRE

    Meunier, Andreas

    2008-01-01

    Adverse effects of cyclooxygenase (COX) inhibitors on bone healing have previously been demonstrated in diaphyseal fracture models in animals. In spite of that, they are widely used as postoperative analgesics in orthopaedic surgery. After joint replacement, a bone repair process starts at the interface between bone and cement. If this process is disturbed, the prosthesis may never become rigidly fixed to the bone, leading to migration and with time loosening. This thesis investigates the eff...

  13. [Directions for reoperation of patients with Björk-Shiley convexo-concave valve prosthesis, based on long-term experience].

    Science.gov (United States)

    Yamaki, F; Nakano, K; Endo, M; Hashimoto, A; Koyanagi, H

    1994-02-01

    Although a high incidence of strut fracture of the Björk-Shiley convexo-concave (C-C) valve prosthesis has been reported, it is still controversial whether the prosthesis functioning normally should be replaced electively. To clarify our policy for this issue, we reviewed 28 patients who had undergone mitral valve replacement with a C-C valve prosthesis, and evaluated long-term results according to STS guidelines. The incidence of valve-related complications expressed as % patient-year were; structural deterioration 0.30, nonstructural dysfunction 0.30, thromboembolism 1.20. There were no thrombosed valves, anticoagulant-related hemorrhage or prosthetic valve endocarditis. The actuarial free rate after valve replacement with the C-C at 10 years, constructed by the Kaplan-Meier method, were compared with those with St. Jude Medical (SJM) valve prosthesis. (1) Actuarial survival: 77.9 vs 87.3 (NS), (2) Reoperation-free: 91.6 vs 98.0 (p valve-related complications: 71.2 vs 77.7 (NS). The long-term results with the C-C were compatible to those with a SJM valve prosthesis. However, if a strut fracture occurs, it is very difficult to save the patient's life. The hospital mortality of re-replacement of valve prosthesis during the last 10 years, at our institute, was 2.6%, which is almost equal to the cumulative risk of strut fracture of the C-C valve after 10 years (3.0%).(ABSTRACT TRUNCATED AT 250 WORDS)

  14. Above-knee prosthesis design based on fatigue life using finite element method and design of experiment.

    Science.gov (United States)

    Phanphet, Suwattanarwong; Dechjarern, Surangsee; Jomjanyong, Sermkiat

    2017-05-01

    The main objective of this work is to improve the standard of the existing design of knee prosthesis developed by Thailand's Prostheses Foundation of Her Royal Highness The Princess Mother. The experimental structural tests, based on the ISO 10328, of the existing design showed that a few components failed due to fatigue under normal cyclic loading below the required number of cycles. The finite element (FE) simulations of structural tests on the knee prosthesis were carried out. Fatigue life predictions of knee component materials were modeled based on the Morrow's approach. The fatigue life prediction based on the FE model result was validated with the corresponding structural test and the results agreed well. The new designs of the failed components were studied using the design of experimental approach and finite element analysis of the ISO 10328 structural test of knee prostheses under two separated loading cases. Under ultimate loading, knee prosthesis peak von Mises stress must be less than the yield strength of knee component's material and the total knee deflection must be lower than 2.5mm. The fatigue life prediction of all knee components must be higher than 3,000,000 cycles under normal cyclic loading. The design parameters are the thickness of joint bars, the diameter of lower connector and the thickness of absorber-stopper. The optimized knee prosthesis design meeting all the requirements was recommended. Experimental ISO 10328 structural test of the fabricated knee prosthesis based on the optimized design confirmed the finite element prediction. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  15. A Preliminary Report on Combined Penoscrotal and Perineal Approach for Placement of Penile Prosthesis with Corporal Fibrosis

    Directory of Open Access Journals (Sweden)

    John P. Brusky

    2008-01-01

    Full Text Available Purpose. This paper aims at describing the combined penoscrotal and perineal approach for placement of penile prosthesis in cases of severe corporal fibrosis and scarring. Materials and methods. Three patients with extensive corporal fibrosis underwent penile prosthesis placement via combined penoscrotal and perineal approach from 1997 to 2006. Follow-up ranged from 15 to 129 months. Results. All patients underwent successful implantation of semirigid penile prosthesis. There were no short- or long-term complications. Conclusions. Results on combined penoscrotal and perineal approach to penile prosthetic surgery in this preliminary series of patients suggest that it is a safe technique and increases the chance of successful outcome in the surgical management of severe corporal fibrosis.

  16. Photoluminescence and electrical properties of silicon oxide and silicon nitride superlattices containing silicon nanocrystals

    International Nuclear Information System (INIS)

    Shuleiko, D V; Ilin, A S

    2016-01-01

    Photoluminescence and electrical properties of superlattices with thin (1 to 5 nm) alternating silicon-rich silicon oxide or silicon-rich silicon nitride, and silicon oxide or silicon nitride layers containing silicon nanocrystals prepared by plasma-enhanced chemical vapor deposition with subsequent annealing were investigated. The entirely silicon oxide based superlattices demonstrated photoluminescence peak shift due to quantum confinement effect. Electrical measurements showed the hysteresis effect in the vicinity of zero voltage due to structural features of the superlattices from SiOa 93 /Si 3 N 4 and SiN 0 . 8 /Si 3 N 4 layers. The entirely silicon nitride based samples demonstrated resistive switching effect, comprising an abrupt conductivity change at about 5 to 6 V with current-voltage characteristic hysteresis. The samples also demonstrated efficient photoluminescence with maximum at ∼1.4 eV, due to exiton recombination in silicon nanocrystals. (paper)

  17. Functional evaluation of a CAD/CAM prosthesis for immediate defect repair after total maxillectomy: a case series of 18 patients with maxillary sinus cancer.

    Science.gov (United States)

    Jiang, Fei-Fei; Hou, Yan; Lu, Li; Ding, Xiao-Xu; Li, Wei; Yan, Ai-Hui

    2015-01-01

    To evaluate the facial profiles and functional recovery of 18 patients treated by a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis) after total maxillectomy for malignant maxillary sinus tumor. A retrospective observational study was performed to evaluate the facial profiles and functional recovery of 18 patients with T3-4a N0 M0 maxillary sinus cancer, who were treated by total maxillectomy and simultaneous implantation of a computer-aided designed/manufactured hollow obturator prosthesis (CAD/CAM prosthesis). Follow-ups were performed 1, 3, 6, and 12 months after surgery. Facial measurements, speech intelligibility, and chewing and swallowing functions were examined. Thirteen patients converted to a permanent prosthesis 6 months after surgery. Comparisons were made between patients with and without the CAD/CAM or permanent prosthesis at various times using SPSS13.0 statistical software (SPSS Inc., Chicago, IL, USA). Speech intelligibility, facial depression, and eyeball prolapse results showed improvements with prosthesis use at 1, 3, and 6 months after surgery (p maxillectomy. This surgical treatment of maxillary sinus cancer is applied rarely in China, but it has a good effect based on our observation. Simultaneous CAD/CAM prosthesis implantation after total maxillectomy can recover the facial profile, enhance the speaking, swallowing, and chewing functions, and improve the quality of life of patients. Tumor recurrence can be detected by direct observation of the postoperative maxillary cavity. This technique avoids the need for dental implants because the bottom part of the prosthesis contains a palatal plate with dentures. © 2014 Wiley Periodicals, Inc.

  18. Veno-arterial extracorporeal membrane oxygenation as a bridge for enabling surgery in a patient under cardiogenic shock due to acute mitral prosthesis dysfunction

    Directory of Open Access Journals (Sweden)

    María Elena Arnáiz-García

    2018-04-01

    Full Text Available A 52-year-old male patient, who underwent mitral replacement with a mechanical prosthesis as a child, sustained a cardiac arrest which was successfully resuscitated. Further investigation showed prosthesis malfunction with significant regurgitation in the context of multi-organ failure. In such a life-threatening condition, veno-arterial extracorporeal membrane oxygenation was considered as a rescue procedure to achieve optimisation of clinical status to allow definitive surgical treatment. An unusual complete fracture of the prosthesis was subsequently identified as the cause of acute dysfunction. Keywords: VA-ECMO, Mitral, Prosthesis, Dysfunction, Cardiogenic shock

  19. Percutaneous closure of ductus arteriosus with the amplatzer prosthesis. The Brazilian experience

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Simões

    2001-12-01

    Full Text Available OBJECTIVE - To report the results of percutaneous occlusion of persistent ductus arteriosus with the Amplatzer prosthesis in 2 Brazilian cardiological centers. METHODS - From May 1998 to July 2000, 33 patients with clinical and laboratory diagnosis of persistent ductus arteriosus underwent attempts at percutaneous implantation of the Amplatzer prosthesis. The median age was 36 months (from 6 months to 38 years, and the median weight was 14kg (from 6 to 92kg. Sixteen patients (48.5% were under 2 years of age at the time of the procedure. All patients were followed up with periodical clinical and echocardiographic evaluations to assess the presence and degree of residual shunt and possible complications, such as pseudocoarctation of the aorta and left pulmonary artery stenosis. RESULTS - The minimum diameter of the arterial ducts ranged from 2.5 to 7.0mm (mean of 4.0±1.0, median of 3.9. The rate of success for implantation of the prosthesis was 100%. Femoral pulse was lost in 1 patient. The echocardiogram revealed total closure prior to hospital discharge in 30 patients, and in the follow-up visit 3 months later in the 3 remaining patients. The mean follow-up duration was 6.4±3.4 months. All patients were clinically well, asymptomatic, and did not need medication. No patient had narrowing of the left pulmonary artery or of the aorta. No early or late embolic events occurred, nor did infectious endarteritis. A new hospital admission was not required for any patient. CONCLUSION - The Amplatzer prosthesis for persistent ductus arteriosus is safe and highly effective for occlusion of ductus arteriosus of varied diameters, including large ones in small symptomatic infants.

  20. Hearing improvement after stapedotomy using teflon loop prosthesis

    International Nuclear Information System (INIS)

    Ahmed, S.; Raza, N.

    2006-01-01

    To assess hearing improvement after stapedotomy for otosclerosis using teflon loop prosthesis. Thirty diagnosed cases of otosclerosis were included in the study. Ear with greater air-bone gap was selected and stapedotomy was done using teflon loop prosthesis (size 4 - 4.5 mm). Mild vertigo occurred during immediate postoperative period, which subsided with Inj. Prochlorperazine. Patients were followed-up postsurgically at one month, two months, four months, six months and one year and postoperative air-bone gap was calculated. Out of 30 cases, there were 24 males and 06 females. The age ranged from 18 to 50 years. Twenty-one (70%) patients had bilateral hearing loss and 09 (30%) had tinnitis also. Pre-operative audiograms showed conductive deafness. Carhart's notch was present in 10 (33.3%) cases. Tympanogram revealed loss of stapedial reflex. Postoperatively good hearing improvement was seen in 56.7% (postoperative air-bone gap closure upto 10 dB), fair improvement in 30% (postoperative air bone gap closure from 11 to 20 dB) and poor results in 10% (postoperative air-bone gap more than 21 dB) cases. One patient developed dead ear. (author)

  1. The clinical relevance of advanced artificial feedback in the control of a multi-functional myoelectric prosthesis

    DEFF Research Database (Denmark)

    Markovic, Marko; Schweisfurth, Meike A.; Engels, Leonard F.

    2018-01-01

    . Nonetheless, the benefits of feedback in prosthetics are still debated. The lack of consensus is likely due to the complex nature of sensory feedback during prosthesis control, so that its effectiveness depends on multiple factors (e.g., task complexity, user learning). METHODS: We evaluated the impact...... of these factors with a longitudinal assessment in six amputee subjects, using a clinical setup (socket, embedded control) and a range of tasks (box and blocks, block turn, clothespin and cups relocation). To provide feedback, we have proposed a novel vibrotactile stimulation scheme capable of transmitting...... multiple variables from a multifunction prosthesis. The subjects wore a bracelet with four by two uniformly placed vibro-tactors providing information on contact, prosthesis state (active function), and grasping force. The subjects also completed a questionnaire for the subjective evaluation...

  2. Developing an Ear Prosthesis Fabricated in Polyvinylidene Fluoride by a 3D Printer with Sensory Intrinsic Properties of Pressure and Temperature

    Directory of Open Access Journals (Sweden)

    Ernesto Suaste-Gómez

    2016-03-01

    Full Text Available An ear prosthesis was designed in 3D computer graphics software and fabricated using a 3D printing process of polyvinylidene fluoride (PVDF for use as a hearing aid. In addition, the prosthesis response to pressure and temperature was observed. Pyroelectric and piezoelectric properties of this ear prosthesis were investigated using an astable multivibrator circuit, as changes in PVDF permittivity were observed according to variations of pressure and temperature. The results show that this prosthesis is reliable for use under different conditions of pressure (0 Pa to 16,350 Pa and temperature (2 °C to 90 °C. The experimental results show an almost linear and inversely proportional behavior between the stimuli of pressure and temperature with the frequency response. This 3D-printed ear prosthesis is a promising tool and has a great potentiality in the biomedical engineering field because of its ability to generate an electrical potential proportional to pressure and temperature, and it is the first time that such a device has been processed by the additive manufacturing process (3D printing. More work needs to be carried out to improve the performance, such as electrical stimulation of the nervous system, thereby extending the purpose of a prosthesis to the area of sensory perception.

  3. Multi-body simulation of various falling scenarios for determining resulting loads at the prosthesis interface of transfemoral amputees with osseointegrated fixation.

    Science.gov (United States)

    Welke, Bastian; Schwarze, Michael; Hurschler, Christof; Calliess, Tilman; Seehaus, Frank

    2013-07-01

    Conventionally, transfemoral amputees are treated with a shaft prosthesis fitted over the residual limb. To improve the quality of life of such patients, in particular those with complications relating to conventional attachment (e.g., skin irritation, stump ulcers, and poor motor-control with short stumps), osseointegrated prosthesis fixation implants have been developed and implanted in a limited population of patients. To assess possible damage to the implant/prosthesis during falling scenarios, the loads in high-risk situations were estimated using a multi-body simulation of motion. Five falling scenarios were identified and performed by healthy volunteer wearing safety equipment. Kinematic data and ground reaction forces were captured as input for the inverse-dynamics-based simulations, from which the forces and moments at a typical implant-prosthesis interface location were computed. The estimated peak loads in all five scenarios were of a magnitude that could lead to bone fracture. The largest peak force observed was 3274 ± 519 N, with an associated resultant moment of 176 ± 55 Nm on the prosthesis-implant interface. A typical femur is prone to fracture under this load, thus illustrating the need for a safety-release element in osseointegrated prosthesis fixation. Copyright © 2013 Orthopaedic Research Society.

  4. Developing an Ear Prosthesis Fabricated in Polyvinylidene Fluoride by a 3D Printer with Sensory Intrinsic Properties of Pressure and Temperature.

    Science.gov (United States)

    Suaste-Gómez, Ernesto; Rodríguez-Roldán, Grissel; Reyes-Cruz, Héctor; Terán-Jiménez, Omar

    2016-03-04

    An ear prosthesis was designed in 3D computer graphics software and fabricated using a 3D printing process of polyvinylidene fluoride (PVDF) for use as a hearing aid. In addition, the prosthesis response to pressure and temperature was observed. Pyroelectric and piezoelectric properties of this ear prosthesis were investigated using an astable multivibrator circuit, as changes in PVDF permittivity were observed according to variations of pressure and temperature. The results show that this prosthesis is reliable for use under different conditions of pressure (0 Pa to 16,350 Pa) and temperature (2 °C to 90 °C). The experimental results show an almost linear and inversely proportional behavior between the stimuli of pressure and temperature with the frequency response. This 3D-printed ear prosthesis is a promising tool and has a great potentiality in the biomedical engineering field because of its ability to generate an electrical potential proportional to pressure and temperature, and it is the first time that such a device has been processed by the additive manufacturing process (3D printing). More work needs to be carried out to improve the performance, such as electrical stimulation of the nervous system, thereby extending the purpose of a prosthesis to the area of sensory perception.

  5. Prosthesis use in adult acquired major upper-limb amputees: patterns of wear, prosthetic skills and the actual use of prostheses in activities of daily life.

    Science.gov (United States)

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-11-01

    To describe patterns of prosthesis wear and perceived prosthetic usefulness in adult acquired upper-limb amputees (ULAs). To describe prosthetic skills in activities of daily life (ADL) and the actual use of prostheses in the performance of ADL tasks. To estimate the influence of prosthetic skills on actual prosthesis use and the influence of background factors on prosthetic skills and actual prosthesis use. Cross-sectional study analysing population-based questionnaire data (n = 224) and data from interviews and clinical testing in a referred/convenience sample of prosthesis-wearing ULAs (n = 50). Effects were analysed using linear regression. 80.8% wore prostheses. 90.3% reported their most worn prosthesis as useful. Prosthetic usefulness profiles varied with prosthetic type. Despite demonstrating good prosthetic skills, the amputees reported actual prosthesis use in only about half of the ADL tasks performed in everyday life. In unilateral amputees, increased actual use was associated with sufficient prosthetic training and with the use of myoelectric vs cosmetic prostheses, regardless of amputation level. Prosthetic skills did not affect actual prosthesis use. No background factors showed significant effect on prosthetic skills. Most major ULAs wear prostheses. Individualised prosthetic training and fitting of myoelectric rather than passive prostheses may increase actual prosthesis use in ADL.

  6. Verge of Collapse: The Pros/thesis of Art Research

    Science.gov (United States)

    Garoian, Charles R.

    2008-01-01

    This article explores "prosthesis" as a metaphor of embodiment in art-based research to challenge the utopian myth of wholeness and normality in art and the human body. Bearing in mind the correspondences between amputated bodies and the cultural dislocations of art, I propose "prosthetic epistemology" and "prosthetic ontology" as embodied knowing…

  7. Prosthetic Rehabilitation of a Patient with Ocular Defect using Semi-customized Prosthesis: A Case Report

    OpenAIRE

    Putanikar, Nagaraj Y.; Patil, Anandkumar G.; Shetty, Pavithra K.; Nagaral, Suresh; Mithaiwala, Hatimali I.

    2015-01-01

    Severe physical and psychological distress occurs due to disfigurement caused by loss of eye. Ocular prosthesis is the only mode of rehabilitation for the missing eye. There are different materials and techniques used for the fabrication of the same. Resin proved to be the better among the available materials. Either using the stock eye or using customized ocular prosthesis has their own advantages and disadvantages. Through our clinical report, we have fabricated a semi-customized ocular pro...

  8. SU-E-J-230: Effect of Metal Hip Prosthesis On the Accuracy of Electromagnetic Localization and Tracking

    International Nuclear Information System (INIS)

    Butler, W; Merrick, G; Kurko, B; Bittner, N

    2014-01-01

    Purpose: To quantify the effect of metal hip prosthesis on the ability to track and localize electromagnetic transponders. Methods: Three Calypso transponders were implanted into two prostate phantoms. The geometric center of the transponders were identified on computed tomography and set as the isocenter. With the phantom stationary on the treatment table and the tracking array 14-cm above the isocenter, data was acquired by the Calypso system at 10 Hz to establish the uncertainty in measurements. Transponder positional data was acquired with unilateral hip prostheses of different metallic compositions and then with bilateral hips placed at variable separation from the phantom. Results: Regardless of hip prosthesis composition, the average vector displacement in the presence of a unilateral prosthesis was < 0.5 mm. The greatest contribution to overall vector displacement occurred in the lateral dimension. With bilateral hip prosthesis, the average vector displacement was 0.3 mm. The displacement in the lateral dimension was markedly reduced compared with a unilateral hip, suggesting that there was a countervailing effect with bilateral hip prosthesis. The greatest average vector displacement was 0.6 mm and occurred when bilateral hip prostheses were placed within 4 cm of the detector array. Conclusion: Unilateral and bilateral hip prostheses did not have any meaningful effect on the ability to accurately track electromagnetic transponders implanted in a prostate phantom. At clinically realistic distances between the hip and detection array, the average tracking error is negligible

  9. Control of dental prosthesis system with microcontroller.

    Science.gov (United States)

    Kapidere, M; Müldür, S; Güler, I

    2000-04-01

    In this study, a microcontroller-based electronic circuit was designed and implemented for dental prosthesis curing system. Heater, compressor and valve were controlled by 8-bit PIC16C64 microcontroller which is programmed using MPASM package. The temperature and time were controlled automatically by preset values which were inputted from keyboard while the pressure was kept constant. Calibration was controlled and the working range was tested. The test results showed that the system provided a good performance.

  10. Prosthesis-patient mismatch after transcatheter aortic valve implantation using the Edwards SAPIEN™ prosthesis.

    Science.gov (United States)

    Van Linden, Arnaud; Kempfert, Jörg; Blumenstein, Johannes; Rastan, Ardawan; Holzhey, David; Lehmann, Sven; Mohr, Friedrich W; Walther, Thomas

    2013-08-01

    Prosthesis-patient mismatch (PPM) is defined as a too small effective orifice area (EOA) of the prosthetic valve in relation to the patient's body size and has been documented to be related to adverse outcomes after conventional aortic valve replacement (AVR). Aim of this study was to analyze the incidence of PPM after transcatheter aortic valve implantation (T-AVI) using the Edwards SAPIEN prosthesis and its relation to postoperative outcome. 200 consecutive high-risk patients underwent transapical aortic valve implantation (TA-AVI) between February 2006 and January 2009 and fulfilled 1 year follow-up were included. Severe PPM was defined as indexed EOA (EOAi) <0.65 cm2/m2 and moderate PPM as EOAi = 0.65-0.85 cm2/m2, EOA was calculated from transthoracic echocardiographic (TTE) measurements using the continuity equation. Total 112 patients with sufficient postoperative TTE image quality formed the study group. EOAi increased from 0.3 ± 0.1 cm2/m2 (preoperatively) to 1.1 ± 0.4 cm2/m2 after TA-AVI (p < 0.001). According to the standard definitions, PPM was seen in 38.4% of the patients and 9.8% presented with severe PPM. The occurrence of PPM had neither an effect on clinical outcome in terms of NYHA class nor on survival. Patients with PPM had significantly higher postoperative transprosthetic gradients (mean gradient 10.4 ± 4.1 versus 7.1 ± 3.0 mm Hg, p < 0.001). Based on the in vitro EOA data obtained from pulse duplicator measurements, however, none of the patients was judged to have PPM. Transcatheter AVI provides good antegrade hemodynamic function and EOAi improves significantly. According to standardized evaluations PPM occurs after TA-AVI, but it is not associated with adverse outcomes. Thus use of the continuity equation may not adequately reflect the situation after T-AVI or the current definition of PPM is not suitable for T-AVI prostheses. Georg Thieme Verlag KG Stuttgart · New York.

  11. A novel speech prosthesis for mandibular guidance therapy in hemimandibulectomy patient: A clinical report

    Directory of Open Access Journals (Sweden)

    Raghavendra Adaki

    2016-01-01

    Full Text Available Treating diverse maxillofacial patients poses a challenge to the maxillofacial prosthodontist. Rehabilitation of hemimandibulectomy patients must aim at restoring mastication and other functions such as intelligible speech, swallowing, and esthetics. Prosthetic methods such as palatal ramp and mandibular guiding flange reposition the deviated mandible. Such prosthesis can also be used to restore speech in case of patients with debilitating speech following surgical resection. This clinical report gives detail of a hemimandibulectomy patient provided with an interim removable dental speech prosthesis with composite resin flange for mandibular guidance therapy.

  12. In vivo operation of the Boston 15-channel wireless subretinal visual prosthesis

    Science.gov (United States)

    Shire, Douglas B.; Doyle, Patrick; Kelly, Shawn K.; Gingerich, Marcus D.; Chen, Jinghua; Cogan, Stuart F.; Drohan, William A.; Mendoza, Oscar; Theogarajan, Luke; Wyatt, John; Rizzo, Joseph F.

    2010-02-01

    This presentation concerns the engineering development of the Boston visual prosthesis for restoring useful vision to patients blind with degenerative retinal disease. A miniaturized, hermetically-encased, 15-channel wirelessly-operated retinal prosthetic was developed for implantation and pre-clinical studies in Yucatan mini-pig animal models. The prosthesis conforms to the eye and drives a microfabricated polyimide stimulating electrode array having sputtered iridium oxide electrodes. This array is implanted into the subretinal space using a specially-designed ab externo surgical technique; the bulk of the prosthesis is on the surface of the sclera. The implanted device includes a hermetic titanium case containing a 15-channel stimulator chip; secondary power/data receiving coils surround the cornea. Long-term in vitro pulse testing was also performed on the electrodes to ensure their stability over years of operation. Assemblies were first tested in vitro to verify wireless operation of the system in biological saline using a custom RF transmitter circuit and primary coils. Stimulation pulse strength, duration and frequency were programmed wirelessly using a computer with a custom graphical user interface. Operation of the retinal implant was verified in vivo in 3 minipigs for more than three months by measuring stimulus artifacts on the eye surface using contact lens electrodes.

  13. Reliability of MRI findings in candidates for lumbar disc prosthesis

    International Nuclear Information System (INIS)

    Berg, Linda; Espeland, Ansgar; Neckelmann, Gesche; Gjertsen, Oeivind; Hellum, Christian; Johnsen, Lars G.; Eide, Geir E.

    2012-01-01

    Limited reliability data exist for localised magnetic resonance imaging (MRI) findings relevant to planning of treatment with lumbar disc prosthesis and later outcomes. We assessed the reliability of such findings in chronic low back pain patients who were accepted candidates for disc prosthesis. On pretreatment MRI of 170 patients (mean age 41 years; 88 women), three experienced radiologists independently rated Modic changes, disc findings and facet arthropathy at L3/L4, L4/L5 and L5/S1. Two radiologists rerated 126 examinations. For each MRI finding at each disc level, agreement was analysed using the kappa statistic and differences in prevalence across observers using a fixed effects model. All findings at L3/L4 and facet arthropathy at L5/S1 had a mean prevalence <10% across observers and were not further analysed, ensuring interpretable kappa values. Overall interobserver agreement was generally moderate or good (kappa 0.40-0.77) at L4-S1 for Modic changes, nucleus pulposus signal, disc height (subjective and measured), posterior high-intensity zone (HIZ) and disc contour, and fair (kappa 0.24) at L4/L5 for facet arthropathy. Posterior HIZ at L5/S1 and severely reduced subjective disc height at L4/L5 differed up to threefold in prevalence between observers (p < 0.0001). Intraobserver agreement was mostly good or very good (kappa 0.60-1.00). In candidates for disc prosthesis, mostly moderate interobserver agreement is expected for localised MRI findings. (orig.)

  14. Reliability of MRI findings in candidates for lumbar disc prosthesis

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Linda; Espeland, Ansgar [Haukeland University Hospital, Department of Radiology, Bergen (Norway); University of Bergen, Section for Radiology, Department of Surgical Sciences, Bergen (Norway); Neckelmann, Gesche [Haukeland University Hospital, Department of Radiology, Bergen (Norway); Gjertsen, Oeivind [Oslo University Hospital, Department of Neuroradiology, Oslo (Norway); Hellum, Christian [Oslo University Hospital, Department of Orthopaedics, Oslo (Norway); University of Oslo, Department of Orthopaedics, Oslo (Norway); Johnsen, Lars G. [University Hospital of Trondheim, National Centre for Diseases of the Spine, Trondheim (Norway); University Hospital of Trondheim, Orthopaedic Department, Trondheim (Norway); Eide, Geir E. [Haukeland University Hospital, Centre for Clinical Research, Bergen (Norway); University of Bergen, Department of Public Health and Primary Health Care, Bergen (Norway)

    2012-07-15

    Limited reliability data exist for localised magnetic resonance imaging (MRI) findings relevant to planning of treatment with lumbar disc prosthesis and later outcomes. We assessed the reliability of such findings in chronic low back pain patients who were accepted candidates for disc prosthesis. On pretreatment MRI of 170 patients (mean age 41 years; 88 women), three experienced radiologists independently rated Modic changes, disc findings and facet arthropathy at L3/L4, L4/L5 and L5/S1. Two radiologists rerated 126 examinations. For each MRI finding at each disc level, agreement was analysed using the kappa statistic and differences in prevalence across observers using a fixed effects model. All findings at L3/L4 and facet arthropathy at L5/S1 had a mean prevalence <10% across observers and were not further analysed, ensuring interpretable kappa values. Overall interobserver agreement was generally moderate or good (kappa 0.40-0.77) at L4-S1 for Modic changes, nucleus pulposus signal, disc height (subjective and measured), posterior high-intensity zone (HIZ) and disc contour, and fair (kappa 0.24) at L4/L5 for facet arthropathy. Posterior HIZ at L5/S1 and severely reduced subjective disc height at L4/L5 differed up to threefold in prevalence between observers (p < 0.0001). Intraobserver agreement was mostly good or very good (kappa 0.60-1.00). In candidates for disc prosthesis, mostly moderate interobserver agreement is expected for localised MRI findings. (orig.)

  15. Immediate breast reconstruction after skin- or nipple-sparing mastectomy for previously augmented patients: a personal technique.

    Science.gov (United States)

    Salgarello, Marzia; Rochira, Dario; Barone-Adesi, Liliana; Farallo, Eugenio

    2012-04-01

    Breast reconstruction for previously augmented patients differs from breast reconstruction for nonaugmented patients. Many surgeons regard conservation therapy as not feasible for these patients because of implant complications, whether radiotherapy-induced or not. Despite this, most authors agree that mastectomy with immediate breast reconstruction is the most suitable choice, ensuring both a good cosmetic result and a low complication rate. Implant retention or removal remains a controversial topic in addition to the best available surgical technique. This study reviewed the authors' experience with immediate breast reconstruction after skin-sparing mastectomy (SSM) and nipple-sparing mastectomy (NSM) with anatomically definitive implants. The retrospective records of 12 patients were examined (group A). These patients were among 254 patients who underwent SSM or NSM for breast carcinoma. The control group comprised 12 of the 254 patients submitted to SSM or NSM (group B) who best matched the 12 patients in the studied group. All of them underwent immediate breast reconstruction, with an anatomically definitive implant placed in a submuscular-subfascial pocket. The demographic, technical, and oncologic data of the two groups were compared as well as the aesthetic outcomes using the Breast Q score. The proportion of complications, the type of implant, the axillary lymph node procedure, and the histology were compared between the two groups using Fisher's exact test. Student's t test was used to compare the scores for the procedure-specific modules of the breast Q questionnaire in the two groups. A validated patient satisfaction score was obtained using the breast Q questionnaire after breast reconstruction. The demographic, technical, and oncologic characteristics were not significantly different between the two groups. The previously augmented patients reported a significantly higher level of satisfaction with their breast than the control patients. The scores

  16. [Mid-term effectiveness of total hip arthroplasty with collum femoris preserving prosthesis].

    Science.gov (United States)

    Li, Mingqing; Hu, Yihe; Li, Kanghua; Liao, Qiande; Wen, Ting; Zhong, Da

    2012-08-01

    To discuss the clinical application of total hip arthroplasty (THA) with collum femoris preserving (CFP) prosthesis and to analyze the mid-term effectiveness. Between January 2004 and February 2007, 45 patients (48 hips) underwent THA with CFP prosthesis. There were 29 males (31 hips) and 16 females (17 hips) with an average age of 48.8 years (range, 38-60 years), including 20 left hips, 22 right hips, and 3 bilateral hips. The causes of hip replacement were osteoarthritis (20 cases), avascular necrosis of femoral head (13 cases), dysplasia (4 cases), rheumatoid arthritis (3 cases), posttraumatic osteoarthritis (2 cases), ankylosing spondylitis (2 cases), and Perths disease (1 case). The average disease duration was 6.1 years (range, 2-13 years). Harris scores, visual analogue scale (VAS) score, and the hip range of motion (ROM) were recorded at pre- and post-operation. The X-ray films were taken at pre- and post-operation to observe the position, loosening of the prosthesis, and ectopic ossification. The gait of patients were also evaluated during follow-up. Short-form 36 health survey scale (SF-36) was used to evaluate the life quality of patients. All 45 patients were followed up 5-8 years with an average of 6.4 years. All the incisions healed by first intention. No infection, hip dislocation, nerve injury, or deep vein thrombosis occurred. Six cleavage fractures (13.3%) of the lateral femoral diaphysis at the distal prosthesis occurred during operation, which healed at 8 months postoperatively without any treatment. Mild ectopic ossification occurred in 4 patients (8.9%) who had no discomfort. Five patients (11.1%) had bone mineral density loss in the region of the proximal femur. The survival rates of the cups and stems were all 100% at last follow-up. The results of Harris score, VAS score, and ROM of the hip joint at 1 year postoperatively and last follow-up were significantly better than preoperative ones (P 0.05) except the Harris score (P fair in 6 hips

  17. Effect of prosthesis endplate lordosis angles on L5-S1 kinematics after disc arthroplasty.

    Science.gov (United States)

    Tsitsopoulos, Parmenion P; Wojewnik, Bartosz; Voronov, Leonard I; Havey, Robert M; Renner, Susan M; Zelenakova, Julia; McIntosh, Braden; Carandang, Gerard; Abjornson, Celeste; Patwardhan, Avinash G

    2012-06-01

    We hypothesized that L5-S1 kinematics will not be affected by the lordosis distribution between the prosthesis endplates. Twelve cadaveric lumbosacral spines (51.3 ± 9.8 years) were implanted with 6° or 11° prostheses (ProDisc-L) with four combinations of superior/inferior lordosis (6°/0°, 3°/3°, 11°/0°, 3°/8°). Specimens were tested intact and after prostheses implantation with different lordosis distributions. Center of rotation (COR) and range of motion (ROM) were quantified. Six-degree lordosis prostheses (n = 7) showed no difference in flexion-extension ROM, regardless of design (6°/0° or 3°/3°) (p > 0.05). In lateral bending (LB), both designs reduced ROM (p lordosis prostheses (n = 5) showed no difference in flexion-extension ROM for either design (p > 0.05). LB ROM decreased with distributed lordosis prostheses (3°/8°) (p lordosis distribution among the two prosthesis endplates. The ProDisc-L prosthesis design where all lordosis is concentrated in the superior endplate yielded COR locations that were anterior and caudal to intact controls. The prosthesis with lordosis distributed between the two endplates yielded a COR that tended to be closer to intact. Further clinical and biomechanical studies are needed to assess the long-term impact of lordosis angle distribution on the fate of the facet joints.

  18. Radiologic images of an aggressive implant-associated fibromatosis of the breast and chest wall: case report and review of the literature

    Directory of Open Access Journals (Sweden)

    Lourdes Alanis, MD, MPH

    2017-09-01

    Full Text Available Fibromatosis of the breast is a rare benign disease compromising <0.2% of all primary breast tumors. Although the chest wall is a common location, occurrences of implant-associated fibromatosis of the breast are extremely rare; only 33 cases have been reported. We present a case of a 42-year-old female who underwent breast augmentation with silicone breast implants, and 2 years later developed an aggressive implant-associated fibromatosis of the breast and chest wall. On imaging studies, the tumor mimicked breast carcinoma, and despite chemotherapy, the fibromatosis rapidly enlarged and was locally invasive requiring wide surgical excision. Unlike previously reported imaging findings, magnetic resonance imaging revealed an oval circumscribed mass with fringe-like internal architecture. We provide a review of the literature and discuss the imaging features of implant-associated fibromatosis of the breast.

  19. [Study of satisfaction of testicular prosthesis implantation in children].

    Science.gov (United States)

    Martínez, Y; Millán, A; Gilabert, R; Delgado, L; De Agustín, J C

    2012-01-01

    Testicular absence may cause psychological trauma in children. It can be avoided by placing testicular prosthesis (TP). However there is no consensus on the optimal age of implantation. We evaluate the results of TP implantation and their complications, as well as patient and family satisfaction. This is a retrospective study of TP implanted between 2004-2010 in our center. Variables analyzed are: age, size and side, indication, surgical technique, complications and comorbidity. Telephone survey was done by a single interviewer to 50 families. general family satisfaction, characteristics of the prosthesis (size, shape, location and consistency), body image and psychological situation of the child, duration of analgesia after surgery, reoperation rate, and family advice to other parents. Statistical analysis with SPSS-18.0. 107 prostheses were placed (4 bilateral, 64 left and 35 rights) at a mean age of 70,10 +/- 58,6 months. The most common indication was cryptorchidism (48.2%). Initial inguinal approach in 69%, and simultaneous contralateral orchidopexy in 29.9%. Only one patient refused the prostheses. In 71% the mother was interviewed. Parents consider size, shape and position appropriate in 55.6%, 66.7% and 82.22% respectively. Hard consistency of TP was considered in 82.3% of the patients. Psychological problems were absent in 86.7%. Nighty five percent would be willing to replace when it was necessary. Parents would recommend the intervention to parents in the same situation in 86.7%. Testicular prosthesis avoids psychological trauma. The lack of satisfaction regarding to the small size and hardness makes necessary to replace the TP in adulthood. An open question remains whether we should consider the placement of TP in early ages, or if we should establish some indications based on a more rational communication with the family.

  20. Rigorous patient-prosthesis matching of Perimount Magna aortic bioprosthesis.

    Science.gov (United States)

    Nakamura, Hiromasa; Yamaguchi, Hiroki; Takagaki, Masami; Kadowaki, Tasuku; Nakao, Tatsuya; Amano, Atsushi

    2015-03-01

    Severe patient-prosthesis mismatch, defined as effective orifice area index ≤0.65 cm(2) m(-2), has demonstrated poor long-term survival after aortic valve replacement. Reported rates of severe mismatch involving the Perimount Magna aortic bioprosthesis range from 4% to 20% in patients with a small annulus. Between June 2008 and August 2011, 251 patients (mean age 70.5 ± 10.2 years; mean body surface area 1.55 ± 0.19 m(2)) underwent aortic valve replacement with a Perimount Magna bioprosthesis, with or without concomitant procedures. We performed our procedure with rigorous patient-prosthesis matching to implant a valve appropriately sized to each patient, and carried out annular enlargement when a 19-mm valve did not fit. The bioprosthetic performance was evaluated by transthoracic echocardiography predischarge and at 1 and 2 years after surgery. Overall hospital mortality was 1.6%. Only 5 (2.0%) patients required annular enlargement. The mean follow-up period was 19.1 ± 10.7 months with a 98.4% completion rate. Predischarge data showed a mean effective orifice area index of 1.21 ± 0.20 cm(2) m(-2). Moderate mismatch, defined as effective orifice area index ≤0.85 cm(2) m(-2), developed in 4 (1.6%) patients. None developed severe mismatch. Data at 1 and 2 years showed only two cases of moderate mismatch; neither was severe. Rigorous patient-prosthesis matching maximized the performance of the Perimount Magna, and no severe mismatch resulted in this Japanese population of aortic valve replacement patients. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.