  1. Optimization of metal artefact reduction (MAR) sequences for MRI of total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Toms, A.P., E-mail: andoni.toms@nnuh.nhs.u [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Smith-Bateman, C.; Malcolm, P.N.; Cahir, J. [Department of Radiology, Norfolk and Norwich University Hospital Trust, Norwich, Norfolk NR4 7UY (United Kingdom); Graves, M. [University Department of Radiology, Addenbrooke' s Hospital, Cambridge (United Kingdom)

    2010-06-15

    Aim: To describe the relative contribution of matrix size and bandwidth to artefact reduction in order to define optimal sequence parameters for metal artefact reduction (MAR) sequences for MRI of total hip prostheses. Methods and materials: A phantom was created using a Charnley total hip replacement. Mid-coronal T1-weighted (echo time 12 ms, repetition time 400 ms) images through the prosthesis were acquired with increasing bandwidths (150, 300, 454, 592, and 781 Hz/pixel) and increasing matrixes of 128, 256, 384, 512, 640, and 768 pixels square. Signal loss from the prosthesis and susceptibility artefact was segmented using an automated tool. Results: Over 90% of the achievable reduction in artefacts was obtained with matrixes of 256 x 256 or greater and a receiver bandwidth of approximately 400 Hz/pixel or greater. Thereafter increasing the receiver bandwidth or matrix had little impact on reducing susceptibility artefacts. Increasing the bandwidth produced a relative fall in the signal-to-noise ratio (SNR) of between 49 and 56% for a given matrix, but, in practice, the image quality was still satisfactory even with the highest bandwidth and largest matrix sizes. The acquisition time increased linearly with increasing matrix parameters. Conclusion: Over 90% of the achievable metal artefact reduction can be realized with mid-range matrices and receiver bandwidths on a clinical 1.5 T system. The loss of SNR from increasing receiver bandwidth, is preferable to long acquisition times, and therefore, should be the main tool for reducing metal artefact.

  2. Metal artefact reduction for accurate tumour delineation in radiotherapy

    DEFF Research Database (Denmark)

    Kovacs, David Gergely; Rechner, Laura A.; Appelt, Ane L.

    2018-01-01

    Background and purpose: Two techniques for metal artefact reduction for computed tomography were studied in order to identify their impact on tumour delineation in radiotherapy. Materials and methods: Using specially designed phantoms containing metal implants (dental, spine and hip) as well...... delineation significantly (pmetal implant....... as patient images, we investigated the impact of two methods for metal artefact reduction on (A) the size and severity of metal artefacts and the accuracy of Hounsfield Unit (HU) representation, (B) the visual impact of metal artefacts on image quality and (C) delineation accuracy. A metal artefact reduction...

  3. PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging

    International Nuclear Information System (INIS)

    Hilgenfeld, Tim; Heil, Alexander; Bendszus, Martin; Prager, Marcel; Heiland, Sabine; Schwindling, Franz Sebastian; Rammelsberg, Peter; Nittka, Mathias; Grodzki, David

    2017-01-01

    Dental MRI is often impaired by artefacts due to metallic dental materials. Several sequences were developed to reduce susceptibility artefacts. Here, we evaluated a set of sequences for artefact reduction for dental MRI for the first time. Artefact volume, signal-to-noise ratio (SNR) and image quality were assessed on a 3-T MRI for pointwise encoding time reduction with radial acquisition (PETRA), multiple-slab acquisition with view angle tilting gradient, based on a sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) sequence (MSVAT-SPACE), slice-encoding for metal-artefact correction (SEMAC) and compared to a standard SPACE and a standard turbo-spin-echo (TSE) sequence. Field-of-view and acquisition times were chosen to enable in vivo application. Two implant-supported prostheses were tested (porcelain fused to metal non-precious alloy and monolithic zirconia). Smallest artefact was measured for TSE sequences with no difference between the standard TSE and the SEMAC. MSVAT-SPACE reduced artefacts about 56% compared to the standard SPACE. Effect of the PETRA was dependent on sample used. Image quality and SNR were comparable for all sequences except PETRA, which yielded poor results. There is no benefit in terms of artefact reduction for SEMAC compared to standard TSE. Usage of MSVAT-SPACE is advantageous since artefacts are reduced and higher resolution is achieved. (orig.)

  4. PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hilgenfeld, Tim; Heil, Alexander; Bendszus, Martin [Heidelberg University Hospital, Department of Neuroradiology, Heidelberg (Germany); Prager, Marcel; Heiland, Sabine [Heidelberg University Hospital, Department of Neuroradiology, Heidelberg (Germany); Heidelberg University Hospital, Section of Experimental Radiology, Heidelberg (Germany); Schwindling, Franz Sebastian; Rammelsberg, Peter [Heidelberg University Hospital, Department of Prosthodontics, Heidelberg (Germany); Nittka, Mathias; Grodzki, David [Siemens Healthcare GmbH, Erlangen (Germany)

    2017-12-15

    Dental MRI is often impaired by artefacts due to metallic dental materials. Several sequences were developed to reduce susceptibility artefacts. Here, we evaluated a set of sequences for artefact reduction for dental MRI for the first time. Artefact volume, signal-to-noise ratio (SNR) and image quality were assessed on a 3-T MRI for pointwise encoding time reduction with radial acquisition (PETRA), multiple-slab acquisition with view angle tilting gradient, based on a sampling perfection with application-optimised contrasts using different flip angle evolution (SPACE) sequence (MSVAT-SPACE), slice-encoding for metal-artefact correction (SEMAC) and compared to a standard SPACE and a standard turbo-spin-echo (TSE) sequence. Field-of-view and acquisition times were chosen to enable in vivo application. Two implant-supported prostheses were tested (porcelain fused to metal non-precious alloy and monolithic zirconia). Smallest artefact was measured for TSE sequences with no difference between the standard TSE and the SEMAC. MSVAT-SPACE reduced artefacts about 56% compared to the standard SPACE. Effect of the PETRA was dependent on sample used. Image quality and SNR were comparable for all sequences except PETRA, which yielded poor results. There is no benefit in terms of artefact reduction for SEMAC compared to standard TSE. Usage of MSVAT-SPACE is advantageous since artefacts are reduced and higher resolution is achieved. (orig.)

  5. Metal artefact reduction in gemstone spectral imaging dual-energy CT with and without metal artefact reduction software

    International Nuclear Information System (INIS)

    Lee, Young Han; Song, Ho-Taek; Kim, Sungjun; Suh, Jin-Suck; Park, Kwan Kyu

    2012-01-01

    To assess the usefulness of gemstone spectral imaging (GSI) dual-energy CT (DECT) with/without metal artefact reduction software (MARs). The DECTs were performed using fast kV-switching GSI between 80 and 140 kV. The CT data were retro-reconstructed with/without MARs, by different displayed fields-of-view (DFOV), and with synthesised monochromatic energy in the range 40-140 keV. A phantom study of size and CT numbers was performed in a titanium plate and a stainless steel plate. A clinical study was performed in 26 patients with metallic hardware. All images were retrospectively reviewed in terms of the visualisation of periprosthetic regions and the severity of beam-hardening artefacts by using a five-point scale. The GSI-MARs reconstruction can markedly reduce the metal-related artefacts, and the image quality was affected by the prosthesis composition and DFOV. The spectral CT numbers of the prosthesis and periprosthetic regions showed different patterns on stainless steel and titanium plates. Dual-energy CT with GSI-MARs can reduce metal-related artefacts and improve the delineation of the prosthesis and periprosthetic region. We should be cautious when using GSI-MARs because the image quality was affected by the prosthesis composition, energy (in keV) and DFOV. The metallic composition and size should be considered in metallic imaging with GSI-MARs reconstruction. circle Metal-related artefacts can be troublesome on musculoskeletal computed tomography (CT). circle Gemstone spectral imaging (GSI) with dual-energy CT (DECT) offers a novel solution circle GSI and metallic artefact reduction software (GSI-MAR) can markedly reduce these artefacts. circle However image quality is influenced by the prosthesis composition and other parameters. circle We should be aware about potential overcorrection when using GSI-MARs. (orig.)

  6. Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Kidoh, Masafumi; Utsunomiya, Daisuke; Ikeda, Osamu; Tamura, Yoshitaka; Oda, Seitaro; Yuki, Hideaki; Nakaura, Takeshi; Hirai, Toshinori; Yamashita, Yasuyuki [Kumamoto University, Department of Diagnostic Radiology, Faculty of Life Sciences, Kumamoto (Japan); Funama, Yoshinori [Kumamoto University, Department of Medical Physics, Faculty of Life Sciences, Kumamoto (Japan); Kawano, Takayuki [Kumamoto University Graduate School, Department of Neurosurgery, Faculty of Life Sciences Research, Kumamoto (Japan)

    2016-05-15

    We evaluated the effect of a single-energy metal artefact reduction (SEMAR) algorithm for metallic coil artefact reduction in body imaging. Computed tomography angiography (CTA) was performed in 30 patients with metallic coils (10 men, 20 women; mean age, 67.9 ± 11 years). Non-SEMAR images were reconstructed with iterative reconstruction alone, and SEMAR images were reconstructed with the iterative reconstruction plus SEMAR algorithms. We compared image noise around metallic coils and the maximum diameters of artefacts from coils between the non-SEMAR and SEMAR images. Two radiologists visually evaluated the metallic coil artefacts utilizing a four-point scale: 1 = extensive; 2 = strong; 3 = mild; 4 = minimal artefacts. The image noise and maximum diameters of the artefacts of the SEMAR images were significantly lower than those of the non-SEMAR images (65.1 ± 33.0 HU vs. 29.7 ± 10.3 HU; 163.9 ± 54.8 mm vs. 10.3 ± 19.0 mm, respectively; P < 0.001). Better visual scores were obtained with the SEMAR technique (3.4 ± 0.6 vs. 1.0 ± 0.0, P < 0.001). The SEMAR algorithm significantly reduced artefacts caused by metallic coils compared with the non-SEMAR algorithm. This technique can potentially increase CT performance for the evaluation of post-coil embolization complications. (orig.)

  7. Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm

    International Nuclear Information System (INIS)

    Kidoh, Masafumi; Utsunomiya, Daisuke; Ikeda, Osamu; Tamura, Yoshitaka; Oda, Seitaro; Yuki, Hideaki; Nakaura, Takeshi; Hirai, Toshinori; Yamashita, Yasuyuki; Funama, Yoshinori; Kawano, Takayuki

    2016-01-01

    We evaluated the effect of a single-energy metal artefact reduction (SEMAR) algorithm for metallic coil artefact reduction in body imaging. Computed tomography angiography (CTA) was performed in 30 patients with metallic coils (10 men, 20 women; mean age, 67.9 ± 11 years). Non-SEMAR images were reconstructed with iterative reconstruction alone, and SEMAR images were reconstructed with the iterative reconstruction plus SEMAR algorithms. We compared image noise around metallic coils and the maximum diameters of artefacts from coils between the non-SEMAR and SEMAR images. Two radiologists visually evaluated the metallic coil artefacts utilizing a four-point scale: 1 = extensive; 2 = strong; 3 = mild; 4 = minimal artefacts. The image noise and maximum diameters of the artefacts of the SEMAR images were significantly lower than those of the non-SEMAR images (65.1 ± 33.0 HU vs. 29.7 ± 10.3 HU; 163.9 ± 54.8 mm vs. 10.3 ± 19.0 mm, respectively; P < 0.001). Better visual scores were obtained with the SEMAR technique (3.4 ± 0.6 vs. 1.0 ± 0.0, P < 0.001). The SEMAR algorithm significantly reduced artefacts caused by metallic coils compared with the non-SEMAR algorithm. This technique can potentially increase CT performance for the evaluation of post-coil embolization complications. (orig.)

  8. Modelling of polysomnographic respiratory measurements for artefact detection and signal restoration

    International Nuclear Information System (INIS)

    Rathnayake, S I; Abeyratne, U R; Hukins, C; Duce, B

    2008-01-01

    Polysomnography (PSG), which incorporates measures of sleep with measures of EEG arousal, air flow, respiratory movement and oxygenation, is universally regarded as the reference standard in diagnosing sleep-related respiratory diseases such as obstructive sleep apnoea syndrome. Over 15 channels of physiological signals are measured from a subject undergoing a typical overnight PSG session. The signals often suffer from data losses, interferences and artefacts. In a typical sleep scoring session, artefact-corrupted signal segments are visually detected and removed from further consideration. This is a highly time-consuming process, and subjective judgement is required for the job. During typical sleep scoring sessions, the target is the detection of segments of diagnostic interest, and signal restoration is not utilized for distorted segments. In this paper, we propose a novel framework for artefact detection and signal restoration based on the redundancy among respiratory flow signals. We focus on the air flow (thermistor sensors) and nasal pressure signals which are clinically significant in detecting respiratory disturbances. The method treats the respiratory system and other organs that provide respiratory-related inputs/outputs to it (e.g., cardiovascular, brain) as a possibly nonlinear coupled-dynamical system, and uses the celebrated Takens embedding theorem as the theoretical basis for signal prediction. Nonlinear prediction across time (self-prediction) and signals (cross-prediction) provides us with a mechanism to detect artefacts as unexplained deviations. In addition to detection, the proposed method carries the potential to correct certain classes of artefacts and restore the signal. In this study, we categorize commonly occurring artefacts and distortions in air flow and nasal pressure measurements into several groups and explore the efficacy of the proposed technique in detecting/recovering them. The results we obtained from a database of clinical

  9. Dosimetric Evaluation of Metal Artefact Reduction using Metal Artefact Reduction (MAR) Algorithm and Dual-energy Computed Tomography (CT) Method

    Science.gov (United States)

    Laguda, Edcer Jerecho

    Purpose: Computed Tomography (CT) is one of the standard diagnostic imaging modalities for the evaluation of a patient's medical condition. In comparison to other imaging modalities such as Magnetic Resonance Imaging (MRI), CT is a fast acquisition imaging device with higher spatial resolution and higher contrast-to-noise ratio (CNR) for bony structures. CT images are presented through a gray scale of independent values in Hounsfield units (HU). High HU-valued materials represent higher density. High density materials, such as metal, tend to erroneously increase the HU values around it due to reconstruction software limitations. This problem of increased HU values due to metal presence is referred to as metal artefacts. Hip prostheses, dental fillings, aneurysm clips, and spinal clips are a few examples of metal objects that are of clinical relevance. These implants create artefacts such as beam hardening and photon starvation that distort CT images and degrade image quality. This is of great significance because the distortions may cause improper evaluation of images and inaccurate dose calculation in the treatment planning system. Different algorithms are being developed to reduce these artefacts for better image quality for both diagnostic and therapeutic purposes. However, very limited information is available about the effect of artefact correction on dose calculation accuracy. This research study evaluates the dosimetric effect of metal artefact reduction algorithms on severe artefacts on CT images. This study uses Gemstone Spectral Imaging (GSI)-based MAR algorithm, projection-based Metal Artefact Reduction (MAR) algorithm, and the Dual-Energy method. Materials and Methods: The Gemstone Spectral Imaging (GSI)-based and SMART Metal Artefact Reduction (MAR) algorithms are metal artefact reduction protocols embedded in two different CT scanner models by General Electric (GE), and the Dual-Energy Imaging Method was developed at Duke University. All three

  10. Computed Tomography Imaging of a Hip Prosthesis Using Iterative Model-Based Reconstruction and Orthopaedic Metal Artefact Reduction: A Quantitative Analysis.

    Science.gov (United States)

    Wellenberg, Ruud H H; Boomsma, Martijn F; van Osch, Jochen A C; Vlassenbroek, Alain; Milles, Julien; Edens, Mireille A; Streekstra, Geert J; Slump, Cornelis H; Maas, Mario

    To quantify the combined use of iterative model-based reconstruction (IMR) and orthopaedic metal artefact reduction (O-MAR) in reducing metal artefacts and improving image quality in a total hip arthroplasty phantom. Scans acquired at several dose levels and kVps were reconstructed with filtered back-projection (FBP), iterative reconstruction (iDose) and IMR, with and without O-MAR. Computed tomography (CT) numbers, noise levels, signal-to-noise-ratios and contrast-to-noise-ratios were analysed. Iterative model-based reconstruction results in overall improved image quality compared to iDose and FBP (P < 0.001). Orthopaedic metal artefact reduction is most effective in reducing severe metal artefacts improving CT number accuracy by 50%, 60%, and 63% (P < 0.05) and reducing noise by 1%, 62%, and 85% (P < 0.001) whereas improving signal-to-noise-ratios by 27%, 47%, and 46% (P < 0.001) and contrast-to-noise-ratios by 16%, 25%, and 19% (P < 0.001) with FBP, iDose, and IMR, respectively. The combined use of IMR and O-MAR strongly improves overall image quality and strongly reduces metal artefacts in the CT imaging of a total hip arthroplasty phantom.

  11. Reduction of dental metallic artefacts in CT: Value of a newly developed algorithm for metal artefact reduction (O-MAR)

    International Nuclear Information System (INIS)

    Kidoh, M.; Nakaura, T.; Nakamura, S.; Tokuyasu, S.; Osakabe, H.; Harada, K.; Yamashita, Y.

    2014-01-01

    Aim: To evaluate the image quality of O-MAR (Metal Artifact Reduction for Orthopedic Implants) for dental metal artefact reduction. Materials and methods: This prospective study received institutional review board approval and written informed consent was obtained. Thirty patients who had dental implants or dental fillings were included in this study. Computed tomography (CT) images were obtained through the oral cavity and neck during the portal venous phase. The system reconstructed the O-MAR-processed images in addition to the uncorrected images. CT attenuation and image noise of the soft tissue of the oral cavity were compared between the O-MAR and the uncorrected images. Qualitative analysis was undertaken between the two image groups. Results: The image noise of the O-MAR images was significantly lower than that of the uncorrected images (p < 0.01). O-MAR offered plausible attenuations of soft tissue compared with non-O-MAR. Better qualitative scores were obtained in the streaking artefacts and the degree of depiction of the oral cavity with O-MAR compared with non-O-MAR. Conclusion: O-MAR enables the depiction of structures in areas in which this was not previously possible due to dental metallic artefacts in qualitative image analysis. O-MAR images may have a supplementary role in addition to uncorrected images in oral diagnosis

  12. Metal artefact reduction in MRI at both 1.5 and 3.0 T using slice encoding for metal artefact correction and view angle tilting

    Science.gov (United States)

    Reichert, M; Morelli, J N; Nittka, M; Attenberger, U; Runge, V M

    2015-01-01

    Objective: To compare metal artefact reduction in MRI at both 3.0 T and 1.5 T using different sequence strategies. Methods: Metal implants of stainless steel screw and plate within agarose phantoms and tissue specimens as well as three patients with implants were imaged at both 1.5 T and 3.0 T, using view angle tilting (VAT), slice encoding for metal artefact correction with VAT (SEMAC-VAT) and conventional sequence. Artefact reduction in agarose phantoms was quantitatively assessed by artefact volume measurements. Blinded reads were conducted in tissue specimen and human imaging, with respect to artefact size, distortion, blurring and overall image quality. Wilcoxon and Friedman tests for multiple comparisons and intraclass correlation coefficient (ICC) for interobserver agreement were performed with a significant level of p 3.0 T (p 3.0 T. Advances in knowledge: The feasibility of metal artefact reduction with SEMAC-VAT was demonstrated at 3.0-T MR. SEMAC-VAT significantly reduced metal artefacts at both 1.5 and 3.0 T. SEMAC-VAT allowed for better visualization of the tissue structures adjacent to the metal implants. SEMAC-VAT produced consistently better image quality in both tissue specimen and human imaging. PMID:25613398

  13. Assessing ECG signal quality indices to discriminate ECGs with artefacts from pathologically different arrhythmic ECGs.

    Science.gov (United States)

    Daluwatte, C; Johannesen, L; Galeotti, L; Vicente, J; Strauss, D G; Scully, C G

    2016-08-01

    False and non-actionable alarms in critical care can be reduced by developing algorithms which assess the trueness of an arrhythmia alarm from a bedside monitor. Computational approaches that automatically identify artefacts in ECG signals are an important branch of physiological signal processing which tries to address this issue. Signal quality indices (SQIs) derived considering differences between artefacts which occur in ECG signals and normal QRS morphology have the potential to discriminate pathologically different arrhythmic ECG segments as artefacts. Using ECG signals from the PhysioNet/Computing in Cardiology Challenge 2015 training set, we studied previously reported ECG SQIs in the scientific literature to differentiate ECG segments with artefacts from arrhythmic ECG segments. We found that the ability of SQIs to discriminate between ECG artefacts and arrhythmic ECG varies based on arrhythmia type since the pathology of each arrhythmic ECG waveform is different. Therefore, to reduce the risk of SQIs classifying arrhythmic events as noise it is important to validate and test SQIs with databases that include arrhythmias. Arrhythmia specific SQIs may also minimize the risk of misclassifying arrhythmic events as noise.

  14. Eye-lens bismuth shielding in paediatric head CT: artefact evaluation and reduction

    International Nuclear Information System (INIS)

    Raissaki, Maria; Perisinakis, Kostas; Damilakis, John; Gourtsoyiannis, Nicholas

    2010-01-01

    CT scans of the brain, sinuses and petrous bones performed as the initial imaging test for a variety of indications have the potential to expose the eye-lens, considered among the most radiosensitive human tissues, to a radiation dose. There are several studies in adults discussing the reduction of orbital dose resulting from the use of commercially available bismuth-impregnated latex shields during CT examinations of the head. To evaluate bismuth shielding-induced artefacts and to provide suggestions for optimal eye-lens shielding in paediatric head CT. A bismuth shield was placed over the eyelids of 60 consecutive children undergoing head CT. Images were assessed for the presence and severity of artefacts with regard to eye-shield distance and shield wrinkling. An anthropomorphic paediatric phantom and thermoluminescence dosimeters (TLDs) were used to study the effect of eye lens-to-shield distance on shielding efficiency. Shields were tolerated by 56/60 children. Artefacts were absent in 45% of scans. Artefacts on orbits, not affecting and affecting orbit evaluation were noted in 39% and 14% of scans, respectively. Diagnostically insignificant artefacts on intracranial structures were noted in 1 case (2%) with shield misplacement. Mean eye-lens-to-shield distance was 8.8 mm in scans without artefacts, and 4.3 mm and 2.2 mm in scans with unimportant and diagnostically important artefacts, respectively. Artefacts occurred in 8 out of 9 cases with shield wrinkling. Dose reduction remained unchanged for different shield-to-eye distances. Bismuth shielding-related artefacts occurring in paediatric head CT are frequent, superficial and diagnostically insignificant when brain pathology is assessed. Shields should be placed 1 cm above the eyes when orbital pathology is addressed. Shield wrinkling should be avoided. (orig.)

  15. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation.

    Science.gov (United States)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Manhart, Michael; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman

    2018-01-01

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared RESULTS: Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (pprototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. • Metal objects cause artefacts in cone-beam computed tomography (CBCT) imaging. • These artefacts can be corrected by metal artefact reduction (MAR) algorithms. • Corrected images show significantly better visibility of nearby hepatic vessels and tissue. • Better visibility may facilitate image interpretation, save time and radiation exposure.

  16. Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms.

    Science.gov (United States)

    Aissa, Joel; Boos, Johannes; Sawicki, Lino Morris; Heinzler, Niklas; Krzymyk, Karl; Sedlmair, Martin; Kröpil, Patric; Antoch, Gerald; Thomas, Christoph

    2017-11-01

    The purpose of this study was to evaluate the impact of three novel iterative metal artefact (iMAR) algorithms on image quality and artefact degree in chest CT of patients with a variety of thoracic metallic implants. 27 postsurgical patients with thoracic implants who underwent clinical chest CT between March and May 2015 in clinical routine were retrospectively included. Images were retrospectively reconstructed with standard weighted filtered back projection (WFBP) and with three iMAR algorithms (iMAR-Algo1 = Cardiac algorithm, iMAR-Algo2 = Pacemaker algorithm and iMAR-Algo3 = ThoracicCoils algorithm). The subjective and objective image quality was assessed. Averaged over all artefacts, artefact degree was significantly lower for the iMAR-Algo1 (58.9 ± 48.5 HU), iMAR-Algo2 (52.7 ± 46.8 HU) and the iMAR-Algo3 (51.9 ± 46.1 HU) compared with WFBP (91.6 ± 81.6 HU, p algorithms, respectively. iMAR-Algo2 and iMAR-Algo3 reconstructions decreased mild and moderate artefacts compared with WFBP and iMAR-Algo1 (p algorithms led to a significant reduction of metal artefacts and increase in overall image quality compared with WFBP in chest CT of patients with metallic implants in subjective and objective analysis. The iMARAlgo2 and iMARAlgo3 were best for mild artefacts. IMARAlgo1 was superior for severe artefacts. Advances in knowledge: Iterative MAR led to significant artefact reduction and increase image-quality compared with WFBP in CT after implementation of thoracic devices. Adjusting iMAR-algorithms to patients' metallic implants can help to improve image quality in CT.

  17. Quantitative evaluation of photoplethysmographic artifact reduction for pulse oximetry

    Science.gov (United States)

    Hayes, Matthew J.; Smith, Peter R.

    1999-01-01

    Motion artefact corruption of pulse oximeter output, causing both measurement inaccuracies and false alarm conditions, is a primary restriction in the current clinical practice and future applications of this useful technique. Artefact reduction in photoplethysmography (PPG), and therefore by application in pulse oximetry, is demonstrated using a novel non-linear methodology recently proposed by the authors. The significance of these processed PPG signals for pulse oximetry measurement is discussed, with particular attention to the normalization inherent in the artefact reduction process. Quantitative experimental investigation of the performance of PPG artefact reduction is then utilized to evaluate this technology for application to pulse oximetry. While the successfully demonstrated reduction of severe artefacts may widen the applicability of all PPG technologies and decrease the occurrence of pulse oximeter false alarms, the observed reduction of slight artefacts suggests that many such effects may go unnoticed in clinical practice. The signal processing and output averaging used in most commercial oximeters can incorporate these artefact errors into the output, while masking the true PPG signal corruption. It is therefore suggested that PPG artefact reduction should be incorporated into conventional pulse oximetry measurement, even in the absence of end-user artefact problems.

  18. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation

    International Nuclear Information System (INIS)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman; Manhart, Michael

    2018-01-01

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters. In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. (orig.)

  19. Prototype metal artefact reduction algorithm in flat panel computed tomography - evaluation in patients undergoing transarterial hepatic radioembolisation

    Energy Technology Data Exchange (ETDEWEB)

    Hamie, Qeumars Mustafa; Kobe, Adrian Raoul; Mietzsch, Leif; Puippe, Gilbert Dominique; Pfammatter, Thomas; Guggenberger, Roman [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Manhart, Michael [Imaging Concepts, HC AT IN IMC, Siemens Healthcare GmbH, Advanced Therapies, Innovation, Forchheim (Germany)

    2018-01-15

    To investigate the effect of an on-site prototype metal artefact reduction (MAR) algorithm in cone-beam CT-catheter-arteriography (CBCT-CA) in patients undergoing transarterial radioembolisation (RE) of hepatic masses. Ethical board approved retrospective study of 29 patients (mean 63.7±13.7 years, 11 female), including 16 patients with arterial metallic coils, undergoing CBCT-CA (8s scan, 200 degrees rotation, 397 projections). Image reconstructions with and without prototype MAR algorithm were evaluated quantitatively (streak-artefact attenuation changes) and qualitatively (visibility of hepatic parenchyma and vessels) in near- (<1cm) and far-field (>3cm) of artefact sources (metallic coils and catheters). Quantitative and qualitative measurements of uncorrected and MAR corrected images and different artefact sources were compared Quantitative evaluation showed significant reduction of near- and far-field streak-artefacts with MAR for both artefact sources (p<0.001), while remaining stable for unaffected organs (all p>0.05). Inhomogeneities of attenuation values were significantly higher for metallic coils compared to catheters (p<0.001) and decreased significantly for both after MAR (p<0.001). Qualitative image scores were significantly improved after MAR (all p<0.003) with by trend higher artefact degrees for metallic coils compared to catheters. In patients undergoing CBCT-CA for transarterial RE, prototype MAR algorithm improves image quality in proximity of metallic coil and catheter artefacts. (orig.)

  20. Statistical iterative reconstruction for streak artefact reduction when using multidetector CT to image the dento-alveolar structures.

    Science.gov (United States)

    Dong, J; Hayakawa, Y; Kober, C

    2014-01-01

    When metallic prosthetic appliances and dental fillings exist in the oral cavity, the appearance of metal-induced streak artefacts is not avoidable in CT images. The aim of this study was to develop a method for artefact reduction using the statistical reconstruction on multidetector row CT images. Adjacent CT images often depict similar anatomical structures. Therefore, reconstructed images with weak artefacts were attempted using projection data of an artefact-free image in a neighbouring thin slice. Images with moderate and strong artefacts were continuously processed in sequence by successive iterative restoration where the projection data was generated from the adjacent reconstructed slice. First, the basic maximum likelihood-expectation maximization algorithm was applied. Next, the ordered subset-expectation maximization algorithm was examined. Alternatively, a small region of interest setting was designated. Finally, the general purpose graphic processing unit machine was applied in both situations. The algorithms reduced the metal-induced streak artefacts on multidetector row CT images when the sequential processing method was applied. The ordered subset-expectation maximization and small region of interest reduced the processing duration without apparent detriments. A general-purpose graphic processing unit realized the high performance. A statistical reconstruction method was applied for the streak artefact reduction. The alternative algorithms applied were effective. Both software and hardware tools, such as ordered subset-expectation maximization, small region of interest and general-purpose graphic processing unit achieved fast artefact correction.

  1. Metal artefact reduction for a dental cone beam CT image using image segmentation and backprojection filters

    International Nuclear Information System (INIS)

    Mohammadi, Mahdi; Khotanlou, Hassan; Mohammadi, Mohammad

    2011-01-01

    Full text: Due to low dose delivery and fast scanning, the dental Cone Beam CT (CBCT) is the latest technology being implanted for a range of dental imaging. The presence of metallic objects including amalgam or gold fillings in the mouth produces an intuitive image for human jaws. The feasibility of a fast and accurate approach for metal artefact reduction for dental CBCT is investigated. The current study investigates the metal artefact reduction using image segmentation and modification of several sinigrams. In order to reduce metal effects such as beam hardening, streak artefact and intense noises, the application of several algorithms is evaluated. The proposed method includes three stages: preprocessing, reconstruction and post-processing. In the pre-processing stage, in order to reduce the noise level, several phase and frequency filters were applied. At the second stage, based on the specific sinogram achieved for each segment, spline interpolation and weighting backprojection filters were applied to reconstruct the original image. A three-dimensional filter was then applied on reconstructed images, to improve the image quality. Results showed that compared to other available filters, standard frequency filters have a significant influence in the preprocessing stage (ΔHU = 48 ± 6). In addition, with the streak artefact, the probability of beam hardening artefact increases. t e post-processing stage, the application of three-dimensional filters improves the quality of reconstructed images (See Fig. I). Conclusion The proposed method reduces metal artefacts especially where there are more than one metal implanted in the region of interest.

  2. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Wellenberg, R.H.H., E-mail: r.h.wellenberg@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Boomsma, M.F., E-mail: m.f.boomsma@isala.nl [Department of Radiology, Isala, Zwolle (Netherlands); Osch, J.A.C. van, E-mail: j.a.c.van.osch@isala.nl [Department of Radiology, Isala, Zwolle (Netherlands); Vlassenbroek, A., E-mail: alain.vlassenbroek@philips.com [Philips Medical Systems, Brussels (Belgium); Milles, J., E-mail: julien.milles@philips.com [Philips Medical Systems, Eindhoven (Netherlands); Edens, M.A., E-mail: m.a.edens@isala.nl [Department of Innovation and Science, Isala, Zwolle (Netherlands); Streekstra, G.J., E-mail: g.j.streekstra@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands); Slump, C.H., E-mail: c.h.slump@utwente.nl [MIRA Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede (Netherlands); Maas, M., E-mail: m.maas@amc.uva.nl [Department of Radiology, Academic Medical Centre, Amsterdam (Netherlands)

    2017-03-15

    Highlights: • Dual-layer detector CT reduces metal artefacts at high monochromatic energies (keV). • 130 keV images were optimal based on quantitative analysis on CNRs. • Optimal keVs varied from 74 to 150 keV for different hip prostheses configurations. • The Titanium alloy resulted in less severe artefacts compared to the Cobalt alloy. • Severe metal artefacts, caused by extensive photon-starvation, were not reduced. - Abstract: Purpose: To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. Methods: The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer detector Spectral CT scanner at 120-kVp and 140-kVp at a standard computed tomography dose index of 20.0 mGy. Several unilateral and bilateral hip prostheses consisting of different metal alloys were inserted and combined which were surrounded by 18 hydroxyapatite calcium carbonate pellets representing bone. Images were reconstructed with iterative reconstruction and analysed at monochromatic energies ranging from 40 to 200 keV. CT numbers in Hounsfield Units (HU), noise measured as the standard deviation in HU, signal-to-noise-ratios (SNRs) and contrast-to-noise-ratios (CNRs) were analysed within fixed regions-of-interests placed in and around the pellets. Results: In 70 and 74 keV virtual monochromatic images the CT numbers of the pellets were similar to 120-kVp and 140-kVp polychromatic results, therefore serving as reference. A separation into three categories of metal artefacts was made (no, mild/moderate and severe) where pellets were categorized based on HU deviations. At high keV values overall image contrast was reduced. For mild/moderate artefacts, the highest average CNRs were attained with virtual monochromatic 130 keV images, acquired at 140-kVp. Severe metal artefacts were not reduced. In 130 keV images

  3. A portable system for acquiring and removing motion artefact from ECG signals

    Science.gov (United States)

    Griffiths, A.; Das, A.; Fernandes, B.; Gaydecki, P.

    2007-07-01

    A novel electrocardiograph (ECG) signal acquisition and display system is under development. It is designed for patients ranging from the elderly to athletes. The signals are obtained from electrodes integrated into a vest, amplified, digitally processed and transmitted via Bluetooth to a PC with a Labview ® interface. Digital signal processing is performed to remove movement artefact and electromyographic (EMG) noise, which severely distorts signal morphology and complicates clinical diagnosis. Independent component analysis (ICA) is also used to improve the signal quality. The complete system will integrate the electronics into a single module which will be embedded in the vest.

  4. A portable system for acquiring and removing motion artefact from ECG signals

    Energy Technology Data Exchange (ETDEWEB)

    Griffiths, A; Das, A; Fernandes, B; Gaydecki, P [School of Electrical and Electronic Engineering, University of Manchester, PO Box 88, Manchester M60 1QD (United Kingdom)

    2007-07-15

    A novel electrocardiograph (ECG) signal acquisition and display system is under development. It is designed for patients ranging from the elderly to athletes. The signals are obtained from electrodes integrated into a vest, amplified, digitally processed and transmitted via Bluetooth to a PC with a Labview (registered) interface. Digital signal processing is performed to remove movement artefact and electromyographic (EMG) noise, which severely distorts signal morphology and complicates clinical diagnosis. Independent component analysis (ICA) is also used to improve the signal quality. The complete system will integrate the electronics into a single module which will be embedded in the ves000.

  5. Ringing Artefact Reduction By An Efficient Likelihood Improvement Method

    Science.gov (United States)

    Fuderer, Miha

    1989-10-01

    In MR imaging, the extent of the acquired spatial frequencies of the object is necessarily finite. The resulting image shows artefacts caused by "truncation" of its Fourier components. These are known as Gibbs artefacts or ringing artefacts. These artefacts are particularly. visible when the time-saving reduced acquisition method is used, say, when scanning only the lowest 70% of the 256 data lines. Filtering the data results in loss of resolution. A method is described that estimates the high frequency data from the low-frequency data lines, with the likelihood of the image as criterion. It is a computationally very efficient method, since it requires practically only two extra Fourier transforms, in addition to the normal. reconstruction. The results of this method on MR images of human subjects are promising. Evaluations on a 70% acquisition image show about 20% decrease of the error energy after processing. "Error energy" is defined as the total power of the difference to a 256-data-lines reference image. The elimination of ringing artefacts then appears almost complete..

  6. Reduction of artefacts due to missing projections using OSEM

    International Nuclear Information System (INIS)

    Hutton, B.F.; Kyme, A.; Choong, K.

    2002-01-01

    Full text: It is well recognised that missing or corrupted projections can result in artefacts. This occasionally occurs due to errors in data transfer from acquisition memory to disk. A possible approach for reducing these artefacts was investigated, Using ordered subsets expectation maximization (OSEM) the iterative reconstruction proceeds by progressively including additional projections until a single iteration is complete. Clinically useful results can be obtained using a small subset size in a single iteration. Stopping prior to the complete iteration so as to avoid inclusion of missing or corrupted data should provide a 'partial' reconstruction with minimal artefacts. To test this hypothesis projections were selectively removed from a complete data set (2, 4, 8, 12 adjacent projections) and reconstructions were performed using both filtered back projection (FBP) and OSEM. To maintain a constant number of sub-iterations in OSEM an equal number of duplicate projections were substituted for the missing projections. Both 180 and 360 degrees reconstructions with missing data were compared with reconstruction for the complete data using sum of absolute differences. Results indicate that missing data causes artefacts for both FBP and OSEM however the severity of artefacts is significantly reduced using OSEM. The effect of missing data is generally greater for 180 degrees acquisition. OSEM is recommended for minimising reconstruction artefacts due to missing projections. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Reduction of ring artefacts in high resolution micro-CT reconstructions

    International Nuclear Information System (INIS)

    Sijbers, Jan; Postnov, Andrei

    2004-01-01

    High resolution micro-CT images are often corrupted by ring artefacts, prohibiting quantitative analysis and hampering post processing. Removing or at least significantly reducing such artefacts is indispensable. However, since micro-CT systems are pushed to the extremes in the quest for the ultimate spatial resolution, ring artefacts can hardly be avoided. Moreover, as opposed to clinical CT systems, conventional correction schemes such as flat-field correction do not lead to satisfactory results. Therefore, in this note a simple but efficient and fast post processing method is proposed that effectively reduces ring artefacts in reconstructed μ-CT images. (note)

  8. Reduction of metal artefacts in musculoskeletal imaging

    International Nuclear Information System (INIS)

    Sutter, Reto; Dietrich, Tobias

    2016-01-01

    Joint replacement and other orthopaedic implants are utilized in many patients with musculoskeletal disorders. While these operations commonly show a good clinical result, a substantial number of patients need to undergo postoperative imaging during follow-up. The presence of orthopaedic implants induces severe metal artefacts at MRI and CT. We review several basic methods and advanced techniques for reducing metal artefacts at MRI and CT in order to enable a diagnostic examination in patients with metal implants. With the use of these techniques, MRI and CT are important and reliable modalities to examine patients with joint replacement and orthopaedic implants.

  9. Magnetic resonance angiography with ultrashort echo times reduces the artefact of aneurysm clips

    International Nuclear Information System (INIS)

    Goenner, F.; Heid, O.; Remonda, L.; Schroth, G.; Loevblad, K.O.; Guzman, R.; Barth, A.

    2002-01-01

    We evaluated the ability of an ultrashort echo time (TE) three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) sequence to reduce the metal artefact of intracranial aneurysm clips and to display adjacent cerebral arteries. In five patients (aged 8-72 years) treated with Elgiloy or Phynox aneurysm clips we prospectively performed a conventional (TE 6.0 ms) and a new ultrashort TE (TE 2.4 ms) 3D TOF MRA. We compared the diameter of the clip-induced susceptibility artefact and the detectability of flow in adjacent vessels. The mean artefact diameter was 22.3±6.4 mm (range 14-38 mm) with the ultrashort TE and 27.7±6.4 mm (range 19-45 mm) with the conventional MRA (P<0.0001). This corresponded to a diameter reduction of 19.5±9.2%. More parts of adjacent vessels were detected, but with less intense flow signal. The aneurysm dome and neck remained within the area of signal loss and were therefore not displayed. Ultrashort TE MRA is a noninvasive and fast method for improving detection of vessels adjacent to clipped intracranial aneurysms, by reducing clip-induced susceptibility artefact. The method cannot, however, be used to show remnants of the aneurysm neck or sac as a result of imperfect clipping. (orig.)

  10. Evaluation of efficacy of metal artefact reduction technique using contrast media in Computed Tomography

    Science.gov (United States)

    Yusob, Diana; Zukhi, Jihan; Aziz Tajuddin, Abd; Zainon, Rafidah

    2017-05-01

    The aim of this study was to evaluate the efficacy of metal artefact reduction using contrasts media in Computed Tomography (CT) imaging. A water-based abdomen phantom of diameter 32 cm (adult body size) was fabricated using polymethyl methacrylate (PMMA) material. Three different contrast agents (iodine, barium and gadolinium) were filled in small PMMA tubes and placed inside a water-based PMMA adult abdomen phantom. The orthopedic metal screw was placed in each small PMMA tube separately. These two types of orthopedic metal screw (stainless steel and titanium alloy) were scanned separately. The orthopedic metal crews were scanned with single-energy CT at 120 kV and dual-energy CT at fast kV-switching between 80 kV and 140 kV. The scan modes were set automatically using the current modulation care4Dose setting and the scans were set at different pitch and slice thickness. The use of the contrast media technique on orthopedic metal screws were optimised by using pitch = 0.60 mm, and slice thickness = 5.0 mm. The use contrast media can reduce the metal streaking artefacts on CT image, enhance the CT images surrounding the implants, and it has potential use in improving diagnostic performance in patients with severe metallic artefacts. These results are valuable for imaging protocol optimisation in clinical applications.

  11. Implications of Artefacts Reduction in the Planning CT Originating from Implanted Fiducial Markers

    International Nuclear Information System (INIS)

    Kassim, Iskandar; Joosten, Hans; Barnhoorn, Jaco C.; Heijmen, Ben J.M.; Dirkx, Maarten L.P.

    2011-01-01

    The efficacy of metal artefact reduction (MAR) software to suppress artefacts in reconstructed computed tomography (CT) images originating from small metal objects, like tumor markers and surgical clips, was evaluated. In addition, possible implications of using digital reconstructed radiographs (DRRs), based on the MAR CT images, for setup verification were analyzed. A phantom and 15 patients with different tumor sites and implanted markers were imaged with a multislice CT scanner. The raw image data was reconstructed both with the clinically used filtered-backprojection (FBP) and with the MAR software. Using the MAR software, improvements in image quality were often observed in CT slices with markers or clips. Especially when several markers were located near to each other, fewer streak artefacts were observed than with the FBP algorithm. In addition, the shape and size of markers could be identified more accurately, reducing the contoured marker volumes by a factor of 2. For the phantom study, the CT numbers measured near to the markers corresponded more closely to the expected values. However, the MAR images were slightly more smoothed compared with the images reconstructed with FBP. For 8 prostate cancer patients in this study, the interobserver variation in 3D marker definition was similar (<0.4 mm) when using DRRs based on either FBP or MAR CT scans. Automatic marker matches also showed a similar success rate. However, differences in automatic match results up to 1 mm, caused by differences in the marker definition, were observed, which turned out to be (borderline) statistically significant (p = 0.06) for 2 patients. In conclusion, the MAR software might improve image quality by suppressing metal artefacts, probably allowing for a more reliable delineation of structures. When implanted markers or clips are used for setup verification, the accuracy may slightly be improved as well, which is relevant when using very tight clinical target volume (CTV) to

  12. Preliminary Results of Ocular Artefacts Identification in EEC Series by Neural Network

    Directory of Open Access Journals (Sweden)

    M. Kofronova

    1996-06-01

    Full Text Available The human electroencephalogram (EEG, is record of the electrical activity of the brain and contains useful diagnostic information on a variety of neurological disorders. Normal EEG signal are usually registered from electrodes placed on the scalp, and are often very small in amplitude, of 20 µV. The EEG, like all biomedical signals, is very susceptible to a variety of large signal contamination or artefacts (signals of other than brain activity which reduce its clinical usefulness. For example, blinking or moving eyes produces large electrical potentials around the eyes called the electrooculogram (EOG. The EOG spreads across the scalp to contaminate the EEG, when it is referred to as an ocular artefact (OA. This paper includes method of identification portion of the EEG record where ocular artefact appears and classification its type by neural network.

  13. ECG movement artefacts can be greatly reduced with the aid of a movement absorbing device

    DEFF Research Database (Denmark)

    Harrison, Adrian Paul; Wandall, Kirsten; Thorball, Jørgen

    2007-01-01

    Accurate ECG signal analysis can be confounded by electric lead, and/or electrode movements varying in origin from, for example, hiccups, tremor or patient restlessness. ECG signals recorded using either a conventional electrode holder or with the aid of an electrode holder capable of absorbing...... movement artefacts, were measured on a healthy human subject. Results show a greatly improved stability of the ECG signal recorded using an electrode holder capable of absorbing movement artefacts during periods of lead disturbance, and highlight the movement artefacts that develop when the recording lead...... of a conventional ECG electrode holder is tugged or pulled during theperiod of monitoring. It is concluded that the new design of ECG electrode holder will not only enable clearer signal recordings for clinical assessment, but will reduce the ECG artefacts associated with the transportation of patients, and may...

  14. Quantifying metal artefact reduction using virtual monochromatic dual-layer detector spectral CT imaging in unilateral and bilateral total hip prostheses

    NARCIS (Netherlands)

    Wellenberg, R. H. H.; Boomsma, M. F.; van Osch, J. A. C.; Vlassenbroek, A.; Milles, J.; Edens, M. A.; Streekstra, G. J.; Slump, C. H.; Maas, M.

    2017-01-01

    To quantify the impact of prosthesis material and design on the reduction of metal artefacts in total hip arthroplasties using virtual monochromatic dual-layer detector Spectral CT imaging. The water-filled total hip arthroplasty phantom was scanned on a novel 128-slice Philips IQon dual-layer

  15. Reduction of CT beam hardening artefacts of ethylene vinyl alcohol copolymer by variation of the tantalum content: evaluation in a standardized aortic endoleak phantom

    International Nuclear Information System (INIS)

    Treitl, Karla M.; Scherr, Michael; Foerth, Monika; Braun, Franziska; Maxien, Daniel; Treitl, Marcus

    2015-01-01

    Our aim was to develop an aortic stent graft phantom to simulate endoleak treatment and to find a tantalum content (TC) of ethylene-vinyl-alcohol-copolymer that causes fewer computed tomography (CT) beam hardening artefacts, but still allows for fluoroscopic visualization. Ethylene-vinyl-alcohol-copolymer specimens of different TC (10-50 %, and 100 %) were injected in an aortic phantom bearing a stent graft and endoleak cavities with simulated re-perfusion. Fluoroscopic visibility of the ethylene-vinyl-alcohol-copolymer specimens was analyzed. In addition, six radiologists analyzed endoleak visibility, and artefact intensity of ethylene-vinyl-alcohol-copolymer in CT. Reduction of TC significantly decreased CT artefact intensity of ethylene-vinyl-alcohol-copolymer and increased visibility of endoleak re-perfusion (p < 0.000). It also significantly decreased fluoroscopic visibility of ethylene-vinyl-alcohol-copolymer (R = 0.883, p ≤ 0.01), and increased the active embolic volumes prior to visualization (Δ ≥ 40 μl). Ethylene-vinyl-alcohol-copolymer specimens with a TC of 45-50 % exhibited reasonable visibility, a low active embolic volume and a tolerable CT artefact intensity. The developed aortic stent graft phantom allows for a reproducible simulation of embolization of endoleaks. The data suggest a reduction of the TC of ethylene-vinyl-alcohol-copolymer to 45 -50 % of the original, to interfere less with diagnostic imaging in follow-up CT examinations, while still allowing for fluoroscopic visualization. (orig.)

  16. Triggering Artefacts

    DEFF Research Database (Denmark)

    Mogensen, Preben Holst; Robinson, Mike

    1995-01-01

    and adapting them to specific situations need not be ad hoc.Triggering artefacts are a way of systematically challenging both designers' preunderstandings and the conservatism of work practice. Experiences from the Great Belt tunnel and bridge project are used to illustrate howtriggering artefacts change...

  17. Novel artefact removal algorithms for co-registered EEG/fMRI based on selective averaging and subtraction.

    Science.gov (United States)

    de Munck, Jan C; van Houdt, Petra J; Gonçalves, Sónia I; van Wegen, Erwin; Ossenblok, Pauly P W

    2013-01-01

    Co-registered EEG and functional MRI (EEG/fMRI) is a potential clinical tool for planning invasive EEG in patients with epilepsy. In addition, the analysis of EEG/fMRI data provides a fundamental insight into the precise physiological meaning of both fMRI and EEG data. Routine application of EEG/fMRI for localization of epileptic sources is hampered by large artefacts in the EEG, caused by switching of scanner gradients and heartbeat effects. Residuals of the ballistocardiogram (BCG) artefacts are similarly shaped as epileptic spikes, and may therefore cause false identification of spikes. In this study, new ideas and methods are presented to remove gradient artefacts and to reduce BCG artefacts of different shapes that mutually overlap in time. Gradient artefacts can be removed efficiently by subtracting an average artefact template when the EEG sampling frequency and EEG low-pass filtering are sufficient in relation to MR gradient switching (Gonçalves et al., 2007). When this is not the case, the gradient artefacts repeat themselves at time intervals that depend on the remainder between the fMRI repetition time and the closest multiple of the EEG acquisition time. These repetitions are deterministic, but difficult to predict due to the limited precision by which these timings are known. Therefore, we propose to estimate gradient artefact repetitions using a clustering algorithm, combined with selective averaging. Clustering of the gradient artefacts yields cleaner EEG for data recorded during scanning of a 3T scanner when using a sampling frequency of 2048 Hz. It even gives clean EEG when the EEG is sampled with only 256 Hz. Current BCG artefacts-reduction algorithms based on average template subtraction have the intrinsic limitation that they fail to deal properly with artefacts that overlap in time. To eliminate this constraint, the precise timings of artefact overlaps were modelled and represented in a sparse matrix. Next, the artefacts were disentangled with

  18. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants : a phantom study

    NARCIS (Netherlands)

    Harnish, Roy; Prevrhal, Sven; Alavi, Abass; Zaidi, Habib; Lang, Thomas F.

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of F-18-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom

  19. CT Artefact Reduction by Signal to Thickness Calibration Function Shaping

    Czech Academy of Sciences Publication Activity Database

    Vavřík, Daniel

    2011-01-01

    Roč. 633, č. 1 (2011), s. 177-180 ISSN 0168-9002. [International workshop on radiation imaging detectors /11./. Praha, 26.06.2009-02.07.2009] R&D Projects: GA ČR(CZ) GA103/09/2101 Grant - others:GA MŠk(CZ) LC06041 Program:LC Institutional research plan: CEZ:AV0Z20710524 Keywords : flat field correction * digital radiography * signal to thickness function * beam hardnening correction Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 1.207, year: 2011 http://dx.doi.org/10.1016/j.nima.2010.06.160

  20. Negotiating meaning through artefacts

    DEFF Research Database (Denmark)

    Tavella, Elena

    2015-01-01

    This research contributes to the domain of strategy making, specifically to unpacking the complexity of sociomateriality in strategy discourse. Scholars have emphasized the potential of artefacts to enhance sensemaking during strategizing. However there is a lack of insight into how artefacts...... and conversational aspects are linked at the micro‑level of discourse, also how artefacts and sensemaking shape one another. This research addresses this gap by empirically analyzing strategy discourse within a facilitated modelling workshop. Considering strategizing as a socially constructed activity, the author...... analyzes a workshop transcript to assess the extent to which stakeholders’ appropriation of artefacts supports them in engaging in negotiation of meaning with action implications. Moreover, how artefacts and negotiation of meaning shape one another is identified. The data suggest that appropriating...

  1. Evaluation method of lead measurement accuracy of gears using a wedge artefact

    International Nuclear Information System (INIS)

    Komori, Masaharu; Takeoka, Fumi; Kubo, Aizoh; Okamoto, Kazuhiko; Osawa, Sonko; Sato, Osamu; Takatsuji, Toshiyuki

    2009-01-01

    The reduction of the vibration and noise of gears is an important issue in mechanical devices such as vehicles and wind turbines. The characteristics of the vibration and noise of gears are markedly affected by deviations of the tooth flank form of micrometre order; therefore, a strict quality control of the tooth flank form is required. The accuracy of the lead measurement for a gear-measuring instrument is usually evaluated using a master gear or a lead master. However, it is difficult to manufacture masters with high accuracy because the helix is a complicated geometrical form. In this paper, we propose a method of evaluating a gear-measuring instrument using a wedge artefact, which includes a highly precise plane surface. The concept of the wedge artefact is described and a mathematical model of the measuring condition of the wedge artefact is constructed. Theoretical measurement results for the wedge artefact are calculated. The wedge artefact is designed and produced on the basis of the theoretical measurement results. A measurement experiment using the wedge artefact is carried out and its effectiveness is verified

  2. Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels.

    Science.gov (United States)

    Guggenberger, R; Winklhofer, S; Osterhoff, G; Wanner, G A; Fortunati, M; Andreisek, G; Alkadhi, H; Stolzmann, P

    2012-11-01

    To evaluate optimal monoenergetic dual-energy computed tomography (DECT) settings for artefact reduction of posterior spinal fusion implants of various vendors and spine levels. Posterior spinal fusion implants of five vendors for cervical, thoracic and lumbar spine were examined ex vivo with single-energy (SE) CT (120 kVp) and DECT (140/100 kVp). Extrapolated monoenergetic DECT images at 64, 69, 88, 105 keV and individually adjusted monoenergy for optimised image quality (OPTkeV) were generated. Two independent radiologists assessed quantitative and qualitative image parameters for each device and spine level. Inter-reader agreements of quantitative and qualitative parameters were high (ICC = 0.81-1.00, κ = 0.54-0.77). HU values of spinal fusion implants were significantly different among vendors (P metallic artefacts from implants than SECT. Use of individual keV values for vendor and spine level is recommended. • Artefacts pose problems for CT following posterior spinal fusion implants. • CT images are interpreted better with monoenergetic extrapolation using dual-energy (DE) CT. • DECT extrapolation improves image quality and reduces metallic artefacts over SECT. • There were considerable differences in monoenergy values among vendors and spine levels. • Use of individualised monoenergy values is indicated for different metallic hardware devices.

  3. From artefact to effect: the organising effects of artefacts on teams.

    Science.gov (United States)

    Berlin, Johan M; Carlström, Eric D

    2010-01-01

    Earlier studies have identified artefacts, but have only to a lesser degree looked at their effects. The purpose of this paper is to investigate how artefacts contribute to organisation. A trauma team at a university hospital has been observed and its members interviewed. The trauma team showed itself to be rich on artefacts since it had strong internal driving forces, high legitimacy, and tried to live up to high expectations from the outside. Its members were motivated to be in the forefront of trauma care. Through renewal, the team succeeded in maintaining demarcation. It also succeeded in systemising internal work tasks and made for itself a position in relation to the outside. The team's capacity, however, came to be limited by internal conflicts and battles for prestige. The study shows that informal logic has a strong influence on teams. Teamwork contributed to the development of organisational structure and motivation for the personnel. Earlier studies advocate the important role of artefacts in order to communicate, collaborate, negotiate or coordinate activities. The conclusion is that artefacts also have an organising and developing effect on teams in a fragmented and differentiated healthcare.

  4. Independent component analysis-based artefact reduction: application to the electrocardiogram for improved magnetic resonance imaging triggering

    International Nuclear Information System (INIS)

    Oster, Julien; Pietquin, Olivier; Felblinger, Jacques; Abächerli, Roger; Kraemer, Michel

    2009-01-01

    Electrocardiogram (ECG) is required during magnetic resonance (MR) examination for monitoring patients under anaesthesia or with heart diseases and for synchronizing image acquisition with heart activity (triggering). Accurate and fast QRS detection is therefore desirable, but this task is complicated by artefacts related to the complex MR environment (high magnetic field, radio-frequency pulses and fast switching magnetic gradients). Specific signal processing has been proposed, whether using specific MR QRS detectors or ECG denoising methods. Most state-of-the-art techniques use a connection to the MR system for achieving their task, which is a major drawback since access to the MR system is often restricted. This paper introduces a new method for on-line ECG signal enhancement, called ICARE, which takes advantage of using multi-lead ECG and does not require any connection to the MR system. It is based on independent component analysis (ICA) and applied in real time. This algorithm yields accurate QRS detection for efficient triggering

  5. Reduction of the pace polarization artefact for capture detection applications by a tri-phasic stimulation pulse.

    Science.gov (United States)

    Sutton, R; Fröhlig, G; de Voogt, W G; Goethals, M; Hintringer, F; Kennergren, C; Scanu, P; Guilleman, D; Treese, N; Hartung, W M; Stammwitz, E; Muetstege, A

    2004-11-01

    This study investigated the ability to minimize pace polarization artefacts (PPA) by adjusting the post-stimulus pulse duration of a tri-phasic stimulation pulse. Adjustment of the stimulation pulse was enabled by downloading special study software into an already implanted pacemaker. Tests were performed in a total of 296 atrial leads and 311 ventricular leads. Both chronic and acute leads were included in the study. Statistically significant differences were found in the initial PPA (without any adjustment of the stimulus pulse) between atrial and ventricular leads. In addition, significant differences were observed among various lead models with respect to changes over time in the initial ventricular PPA. Successful PPA reduction was defined as a reduction of the PPA below 0.5 mV for atrial leads and below 1 mV for ventricular leads. Results show a success rate for ventricular and atrial PPA reduction of 97.8% and 98.7%, respectively. Threshold tests showed that after reduction of the PPA loss of ventricular capture can be reliably detected. However, atrial threshold tests showed many false positive evoked response detections. In addition, unexpectedly high evoked response amplitudes were observed in the atrium after reduction of the PPA. Results from additional measurements suggest that these high atrial evoked response amplitudes come from the influence of the input filter of the pacemaker.

  6. Surface-specific additive manufacturing test artefacts

    Science.gov (United States)

    Townsend, Andrew; Racasan, Radu; Blunt, Liam

    2018-06-01

    Many test artefact designs have been proposed for use with additive manufacturing (AM) systems. These test artefacts have primarily been designed for the evaluation of AM form and dimensional performance. A series of surface-specific measurement test artefacts designed for use in the verification of AM manufacturing processes are proposed here. Surface-specific test artefacts can be made more compact because they do not require the large dimensions needed for accurate dimensional and form measurements. The series of three test artefacts are designed to provide comprehensive information pertaining to the manufactured surface. Measurement possibilities include deviation analysis, surface texture parameter data generation, sub-surface analysis, layer step analysis and build resolution comparison. The test artefacts are designed to provide easy access for measurement using conventional surface measurement techniques, for example, focus variation microscopy, stylus profilometry, confocal microscopy and scanning electron microscopy. Additionally, the test artefacts may be simply visually inspected as a comparative tool, giving a fast indication of process variation between builds. The three test artefacts are small enough to be included in every build and include built-in manufacturing traceability information, making them a convenient physical record of the build.

  7. Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study.

    Science.gov (United States)

    Smeets, Ralf; Schöllchen, Maximilian; Gauer, Tobias; Aarabi, Ghazal; Assaf, Alexandre T; Rendenbach, Carsten; Beck-Broichsitter, Benedicta; Semmusch, Jan; Sedlacik, Jan; Heiland, Max; Fiehler, Jens; Siemonsen, Susanne

    2017-02-01

    To analyze and evaluate imaging artefacts induced by zirconium, titanium and titanium-zirconium alloy dental implants. Zirconium, titanium and titanium-zirconium alloy implants were embedded in gelatin and MRI, CT and CBCT were performed. Standard protocols were used for each modality. For MRI, line-distance profiles were plotted to quantify the accuracy of size determination. For CT and CBCT, six shells surrounding the implant were defined every 0.5 cm from the implant surface and histogram parameters were determined for each shell. While titanium and titanium-zirconium alloy induced extensive signal voids in MRI owing to strong susceptibility, zirconium implants were clearly definable with only minor distortion artefacts. For titanium and titanium-zirconium alloy, the MR signal was attenuated up to 14.1 mm from the implant. In CT, titanium and titanium-zirconium alloy resulted in less streak artefacts in comparison with zirconium. In CBCT, titanium-zirconium alloy induced more severe artefacts than zirconium and titanium. MRI allows for an excellent image contrast and limited artefacts in patients with zirconium implants. CT and CBCT examinations are less affected by artefacts from titanium and titanium-zirconium alloy implants compared with MRI. The knowledge about differences of artefacts through different implant materials and image modalities might help support clinical decisions for the choice of implant material or imaging device in the clinical setting.

  8. Artefacts in multimodal imaging of titanium, zirconium and binary titanium–zirconium alloy dental implants: an in vitro study

    Science.gov (United States)

    Schöllchen, Maximilian; Aarabi, Ghazal; Assaf, Alexandre T; Rendenbach, Carsten; Beck-Broichsitter, Benedicta; Semmusch, Jan; Sedlacik, Jan; Heiland, Max; Fiehler, Jens; Siemonsen, Susanne

    2017-01-01

    Objectives: To analyze and evaluate imaging artefacts induced by zirconium, titanium and titanium–zirconium alloy dental implants. Methods: Zirconium, titanium and titanium–zirconium alloy implants were embedded in gelatin and MRI, CT and CBCT were performed. Standard protocols were used for each modality. For MRI, line–distance profiles were plotted to quantify the accuracy of size determination. For CT and CBCT, six shells surrounding the implant were defined every 0.5 cm from the implant surface and histogram parameters were determined for each shell. Results: While titanium and titanium–zirconium alloy induced extensive signal voids in MRI owing to strong susceptibility, zirconium implants were clearly definable with only minor distortion artefacts. For titanium and titanium–zirconium alloy, the MR signal was attenuated up to 14.1 mm from the implant. In CT, titanium and titanium–zirconium alloy resulted in less streak artefacts in comparison with zirconium. In CBCT, titanium–zirconium alloy induced more severe artefacts than zirconium and titanium. Conclusions: MRI allows for an excellent image contrast and limited artefacts in patients with zirconium implants. CT and CBCT examinations are less affected by artefacts from titanium and titanium–zirconium alloy implants compared with MRI. The knowledge about differences of artefacts through different implant materials and image modalities might help support clinical decisions for the choice of implant material or imaging device in the clinical setting. PMID:27910719

  9. Ross filter pairs for metal artefact reduction in x-ray tomography: a case study based on imaging and segmentation of metallic implants

    Science.gov (United States)

    Arhatari, Benedicta D.; Abbey, Brian

    2018-01-01

    Ross filter pairs have recently been demonstrated as a highly effective means of producing quasi-monoenergetic beams from polychromatic X-ray sources. They have found applications in both X-ray spectroscopy and for elemental separation in X-ray computed tomography (XCT). Here we explore whether they could be applied to the problem of metal artefact reduction (MAR) for applications in medical imaging. Metal artefacts are a common problem in X-ray imaging of metal implants embedded in bone and soft tissue. A number of data post-processing approaches to MAR have been proposed in the literature, however these can be time-consuming and sometimes have limited efficacy. Here we describe and demonstrate an alternative approach based on beam conditioning using Ross filter pairs. This approach obviates the need for any complex post-processing of the data and enables MAR and segmentation from the surrounding tissue by exploiting the absorption edge contrast of the implant.

  10. Looking for the Signal: A guide to iterative noise and artefact removal in X-ray tomographic reconstructions of porous geomaterials

    Science.gov (United States)

    Bruns, S.; Stipp, S. L. S.; Sørensen, H. O.

    2017-07-01

    X-ray micro- and nanotomography has evolved into a quantitative analysis tool rather than a mere qualitative visualization technique for the study of porous natural materials. Tomographic reconstructions are subject to noise that has to be handled by image filters prior to quantitative analysis. Typically, denoising filters are designed to handle random noise, such as Gaussian or Poisson noise. In tomographic reconstructions, noise has been projected from Radon space to Euclidean space, i.e. post reconstruction noise cannot be expected to be random but to be correlated. Reconstruction artefacts, such as streak or ring artefacts, aggravate the filtering process so algorithms performing well with random noise are not guaranteed to provide satisfactory results for X-ray tomography reconstructions. With sufficient image resolution, the crystalline origin of most geomaterials results in tomography images of objects that are untextured. We developed a denoising framework for these kinds of samples that combines a noise level estimate with iterative nonlocal means denoising. This allows splitting the denoising task into several weak denoising subtasks where the later filtering steps provide a controlled level of texture removal. We describe a hands-on explanation for the use of this iterative denoising approach and the validity and quality of the image enhancement filter was evaluated in a benchmarking experiment with noise footprints of a varying level of correlation and residual artefacts. They were extracted from real tomography reconstructions. We found that our denoising solutions were superior to other denoising algorithms, over a broad range of contrast-to-noise ratios on artificial piecewise constant signals.

  11. The normativity of artefacts

    NARCIS (Netherlands)

    Franssen, M.

    2006-01-01

    Part of the distinction between artefacts, objects made by humans for particular purposes, and natural objects is that artefacts are subject to normative judgements. A drill, say, can be a good drill or a poor drill, it can function well or correctly or it can malfunction. In this paper I

  12. Lab-based x-ray tomography of a cochlear implant using energy discriminating detectors for metal artefact reduction

    Science.gov (United States)

    Yokhana, Viona S. K.; Arhatari, Benedicta D.; Gureyev, Timur E.; Abbey, Brian

    2018-01-01

    X-ray computed tomography (XCT) is an important clinical diagnostic tool which is also used in a range of biological imaging applications in research. The increasing prevalence of metallic implants in medical and dental radiography and tomography has driven the demand for new approaches to solving the issue of metal artefacts in XCT. Metal artefacts occur when a highly absorbing material is imaged which is in boundary contact with one or more weakly absorbing components, such as soft-tissue. The resulting `streaking' in the reconstructed images creates significant challenges for X-ray analysis due to the non-linear dependence on the absorption properties of the sample. In this paper we introduce a new approach to removing metal artefacts which exploits the capabilities of the recently available, photon-counting PiXirad detector. Our approach works for standard lab-based polychromatic X-ray tubes and does not rely on any postprocessing of the data. The method is demonstrated using both simulated data from a test phantom and experimental data collected from a cochlear implant. The results show that by combining the individual images, which are simultaneously generated for each different energy threshold, artefact -free segmentation of the implant from the surrounding biological tissue is achieved.

  13. A knowledge-based method for reducing attenuation artefacts caused by cardiac appliances in myocardial PET/CT

    International Nuclear Information System (INIS)

    Hamill, James J; Brunken, Richard C; Bybel, Bohdan; DiFilippo, Frank P; Faul, David D

    2006-01-01

    Attenuation artefacts due to implanted cardiac defibrillator leads have previously been shown to adversely impact cardiac PET/CT imaging. In this study, the severity of the problem is characterized, and an image-based method is described which reduces the resulting artefact in PET. Automatic implantable cardioverter defibrillator (AICD) leads cause a moving-metal artefact in the CT sections from which the PET attenuation correction factors (ACFs) are derived. Fluoroscopic cine images were measured to demonstrate that the defibrillator's highly attenuating distal shocking coil moves rhythmically across distances on the order of 1 cm. Rhythmic motion of this magnitude was created in a phantom with a moving defibrillator lead. A CT study of the phantom showed that the artefact contained regions of incorrect, very high CT values and adjacent regions of incorrect, very low CT values. The study also showed that motion made the artefact more severe. A knowledge-based metal artefact reduction method (MAR) is described that reduces the magnitude of the error in the CT images, without use of the corrupted sinograms. The method modifies the corrupted image through a sequence of artefact detection procedures, morphological operations, adjustments of CT values and three-dimensional filtering. The method treats bone the same as metal. The artefact reduction method is shown to run in a few seconds, and is validated by applying it to a series of phantom studies in which reconstructed PET tracer distribution values are wrong by as much as 60% in regions near the CT artefact when MAR is not applied, but the errors are reduced to about 10% of expected values when MAR is applied. MAR changes PET image values by a few per cent in regions not close to the artefact. The changes can be larger in the vicinity of bone. In patient studies, the PET reconstruction without MAR sometimes results in anomalously high values in the infero-septal wall. Clinical performance of MAR is assessed by two

  14. Influence of metallic dental implants and metal artefacts on dose calculation accuracy.

    Science.gov (United States)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-03-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic™ EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques.

  15. Influence of metallic dental implants and metal artefacts on dose calculation accuracy

    International Nuclear Information System (INIS)

    Maerz, Manuel; Koelbl, Oliver; Dobler, Barbara

    2015-01-01

    Metallic dental implants cause severe streaking artefacts in computed tomography (CT) data, which inhibit the correct representation of shape and density of the metal and the surrounding tissue. The aim of this study was to investigate the impact of dental implants on the accuracy of dose calculations in radiation therapy planning and the benefit of metal artefact reduction (MAR). A second aim was to determine the treatment technique which is less sensitive to the presence of metallic implants in terms of dose calculation accuracy. Phantoms consisting of homogeneous water equivalent material surrounding dental implants were designed. Artefact-containing CT data were corrected using the correct density information. Intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) plans were calculated on corrected and uncorrected CT data and compared to 2-dimensional dose measurements using GafChromic trademark EBT2 films. For all plans the accuracy of dose calculations is significantly higher if performed on corrected CT data (p = 0.015). The agreement of calculated and measured dose distributions is significantly higher for VMAT than for IMRT plans for calculations on uncorrected CT data (p = 0.011) as well as on corrected CT data (p = 0.029). For IMRT and VMAT the application of metal artefact reduction significantly increases the agreement of dose calculations with film measurements. VMAT was found to provide the highest accuracy on corrected as well as on uncorrected CT data. VMAT is therefore preferable over IMRT for patients with metallic implants, if plan quality is comparable for the two techniques. (orig.) [de

  16. Preliminary Results of Ocular Artefacts Identification in EEC Series by Neural Network

    OpenAIRE

    Kofronova, M.

    1996-01-01

    The human electroencephalogram (EEG), is record of the electrical activity of the brain and contains useful diagnostic information on a variety of neurological disorders. Normal EEG signal are usually registered from electrodes placed on the scalp, and are often very small in amplitude, of 20 µV. The EEG, like all biomedical signals, is very susceptible to a variety of large signal contamination or artefacts (signals of other than brain activity) which reduce its clinical usefulness. For e...

  17. Comparison of methods for suppressing edge and aliasing artefacts in iterative x-ray CT reconstruction

    International Nuclear Information System (INIS)

    Zbijewski, Wojciech; Beekman, Freek J

    2006-01-01

    X-ray CT images obtained with iterative reconstruction (IR) can be hampered by the so-called edge and aliasing artefacts, which appear as interference patterns and severe overshoots in the areas of sharp intensity transitions. Previously, we have demonstrated that these artefacts are caused by discretization errors during the projection simulation step in IR. Although these errors are inherent to IR, they can be adequately suppressed by reconstruction on an image grid that is finer than that typically used for analytical methods such as filtered back-projection. Two other methods that may prevent edge artefacts are: (i) smoothing the projections prior to reconstruction or (ii) using an image representation different from voxels; spherically symmetric Kaiser-Bessel functions are a frequently employed example of such a representation. In this paper, we compare reconstruction on a fine grid with the two above-mentioned alternative strategies for edge artefact reduction. We show that the use of a fine grid results in a more adequate suppression of artefacts than the smoothing of projections or using the Kaiser-Bessel image representation

  18. Experiential Role of Artefacts in Cooperative Design

    OpenAIRE

    Vyas, Dhaval; Heylen, Dirk K.J.; Nijholt, Antinus; van der Veer, Gerrit C.; Caroll, J.M.

    2009-01-01

    The role of material artefacts in supporting distributed and co-located work practices has been well acknowledged within the HCI and CSCW research. In this paper, we show that in addition to their ecological, coordinative and organizational support, artefacts also play an ‘experiential’ role. In this case, artefacts not only improve efficiency or have a purely functional role (e.g. allowing people to complete tasks quickly), but the presence and manifestations of these artefacts bring quality...

  19. Material culture - artefacts and daily life

    DEFF Research Database (Denmark)

    Roesdahl, Else; Verhaeghe, Frans

    2011-01-01

    A survey of main groups of medieval portable artefacts, with a focus on north-western and central Europe (including Scandinavia), and a discussion of methods and interpretations in artefact studies...

  20. A knowledge-based method for reducing attenuation artefacts caused by cardiac appliances in myocardial PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Hamill, James J [Siemens Medical Solutions, Molecular Imaging, 810 Innovation Dr., Knoxville, TN (United States); Brunken, Richard C [Department of Molecular and Functional Imaging, Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH (United States); Bybel, Bohdan [Department of Molecular and Functional Imaging, Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH (United States); DiFilippo, Frank P [Department of Molecular and Functional Imaging, Cleveland Clinic Foundation, 9500 Euclid Ave., Cleveland, OH (United States); Faul, David D [Siemens Medical Solutions, Molecular Imaging, 810 Innovation Dr., Knoxville, TN (United States)

    2006-06-07

    Attenuation artefacts due to implanted cardiac defibrillator leads have previously been shown to adversely impact cardiac PET/CT imaging. In this study, the severity of the problem is characterized, and an image-based method is described which reduces the resulting artefact in PET. Automatic implantable cardioverter defibrillator (AICD) leads cause a moving-metal artefact in the CT sections from which the PET attenuation correction factors (ACFs) are derived. Fluoroscopic cine images were measured to demonstrate that the defibrillator's highly attenuating distal shocking coil moves rhythmically across distances on the order of 1 cm. Rhythmic motion of this magnitude was created in a phantom with a moving defibrillator lead. A CT study of the phantom showed that the artefact contained regions of incorrect, very high CT values and adjacent regions of incorrect, very low CT values. The study also showed that motion made the artefact more severe. A knowledge-based metal artefact reduction method (MAR) is described that reduces the magnitude of the error in the CT images, without use of the corrupted sinograms. The method modifies the corrupted image through a sequence of artefact detection procedures, morphological operations, adjustments of CT values and three-dimensional filtering. The method treats bone the same as metal. The artefact reduction method is shown to run in a few seconds, and is validated by applying it to a series of phantom studies in which reconstructed PET tracer distribution values are wrong by as much as 60% in regions near the CT artefact when MAR is not applied, but the errors are reduced to about 10% of expected values when MAR is applied. MAR changes PET image values by a few per cent in regions not close to the artefact. The changes can be larger in the vicinity of bone. In patient studies, the PET reconstruction without MAR sometimes results in anomalously high values in the infero-septal wall. Clinical performance of MAR is assessed by

  1. Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

    Energy Technology Data Exchange (ETDEWEB)

    Ghafarian, Pardis [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Aghamiri, S.M.R. [Shahid Beheshti University, Department of Radiation Medicine, Tehran (Iran, Islamic Republic of); Ay, Mohammad R. [Tehran University of Medical Sciences, Research Center for Science and Technology in Medicine, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Department of Medical Physics and Biomedical Engineering, Tehran (Iran, Islamic Republic of); Tehran University of Medical Sciences, Research Institute for Nuclear Medicine, Tehran (Iran, Islamic Republic of); Rahmim, Arman [Johns Hopkins University, Department of Radiology, Baltimore, MD (United States); Schindler, Thomas H. [Geneva University, Cardiovascular Center, Nuclear Cardiology, Geneva (Switzerland); Ratib, Osman [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Zaidi, Habib [Geneva University Hospital, Division of Nuclear Medicine, Geneva 4 (Switzerland); Geneva University, Geneva Neuroscience Center, Geneva (Switzerland)

    2011-02-15

    Cardiac PET/CT imaging is often performed in patients with pacemakers and implantable cardioverter defibrillator (ICD) leads. However, metallic implants usually produce artefacts on CT images which might propagate to CT-based attenuation-corrected (CTAC) PET images. The impact of metal artefact reduction (MAR) for CTAC of cardiac PET/CT images in the presence of pacemaker, ICD and ECG leads was investigated using both qualitative and quantitative analysis in phantom and clinical studies. The study included 14 patients with various leads undergoing perfusion and viability examinations using dedicated cardiac PET/CT protocols. The PET data were corrected for attenuation using both artefactual CT images and CT images corrected using the MAR algorithm. The severity and magnitude of metallic artefacts arising from these leads were assessed on both linear attenuation coefficient maps ({mu}-maps) and attenuation-corrected PET images. CT and PET emission data were obtained using an anthropomorphic thorax phantom and a dedicated heart phantom made in-house incorporating pacemaker and ICD leads attached at the right ventricle of the heart. Volume of interest-based analysis and regression plots were performed for regions related to the lead locations. Bull's eye view analysis was also performed on PET images corrected for attenuation with and without the MAR algorithm. In clinical studies, the visual assessment of PET images by experienced physicians and quantitative analysis did not reveal erroneous interpretation of the tracer distribution or significant differences when PET images were corrected for attenuation with and without MAR. In phantom studies, the mean differences between tracer uptake obtained without and with MAR were 10.16{+-}2.1% and 6.86{+-}2.1% in the segments of the heart in the vicinity of metallic ICD or pacemaker leads, and were 4.43{+-}0.5% and 2.98{+-}0.5% in segments far from the leads. Although the MAR algorithm was able to effectively improve

  2. Artefacts and the performance of an exhibition

    DEFF Research Database (Denmark)

    Svabo, Connie

    2008-01-01

    The article explores the role of mediating artefacts in children's encounters with a museum of natural history. Using actor network theory it explores how a specific artefact shapes the way users relate to exhibited objects and how the artefact guides users' movements in the exhibition....... The mediated performance of an exhibition is explored through an empirical case....

  3. Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels

    Energy Technology Data Exchange (ETDEWEB)

    Guggenberger, R.; Winklhofer, S.; Andreisek, G.; Alkadhi, H.; Stolzmann, P. [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Osterhoff, G.; Wanner, G.A. [University Hospital Zurich, Department of Surgery, Division of Trauma Surgery, Zurich (Switzerland); Fortunati, M. [The Spine Center, Thun (Switzerland)

    2012-11-15

    To evaluate optimal monoenergetic dual-energy computed tomography (DECT) settings for artefact reduction of posterior spinal fusion implants of various vendors and spine levels. Posterior spinal fusion implants of five vendors for cervical, thoracic and lumbar spine were examined ex vivo with single-energy (SE) CT (120 kVp) and DECT (140/100 kVp). Extrapolated monoenergetic DECT images at 64, 69, 88, 105 keV and individually adjusted monoenergy for optimised image quality (OPTkeV) were generated. Two independent radiologists assessed quantitative and qualitative image parameters for each device and spine level. Inter-reader agreements of quantitative and qualitative parameters were high (ICC = 0.81-1.00, {kappa} = 0.54-0.77). HU values of spinal fusion implants were significantly different among vendors (P < 0.001), spine levels (P < 0.01) and among SECT, monoenergetic DECT of 64, 69, 88, 105 keV and OPTkeV (P < 0.01). Image quality was significantly (P < 0.001) different between datasets and improved with higher monoenergies of DECT compared with SECT (V = 0.58, P < 0.001). Artefacts decreased significantly (V = 0.51, P < 0.001) at higher monoenergies. OPTkeV values ranged from 123-141 keV. OPTkeV according to vendor and spine level are presented herein. Monoenergetic DECT provides significantly better image quality and less metallic artefacts from implants than SECT. Use of individual keV values for vendor and spine level is recommended. (orig.)

  4. Advanced digital signal processing and noise reduction

    CERN Document Server

    Vaseghi, Saeed V

    2008-01-01

    Digital signal processing plays a central role in the development of modern communication and information processing systems. The theory and application of signal processing is concerned with the identification, modelling and utilisation of patterns and structures in a signal process. The observation signals are often distorted, incomplete and noisy and therefore noise reduction, the removal of channel distortion, and replacement of lost samples are important parts of a signal processing system. The fourth edition of Advanced Digital Signal Processing and Noise Reduction updates an

  5. Challenges in contrast-enhanced spectral mammography interpretation: artefacts lexicon.

    Science.gov (United States)

    Yagil, Y; Shalmon, A; Rundstein, A; Servadio, Y; Halshtok, O; Gotlieb, M; Sklair-Levy, M

    2016-05-01

    To review and describe commonly encountered artefacts in contrast-enhanced spectral mammography (CESM). This retrospective study included 200 women who underwent CESM examinations for screening and diagnostic purposes. Analysis was performed on the image data sets of these women, comprising of a total of 774 subtracted images. Images were reviewed with focus on the presence of four artefacts: rim ("breast within breast"), ripple (black and white lines), axillary line, and skin-line enhancement (skin-line highlighting). Statistical cross-correlation and association with acquisition parameters (tube current, tube voltage, compression force, breast thickness, paddle size) was compared using Fisher's exact test and t-test. The rim artefact was highly common (97-99%) in every projection. The ripple artefact was increasingly more common on the oblique projections (80-82%) and found to be associated with higher breast thickness values. The axillary line artefact was detected only on oblique projections (63%) and associated with the use of a small compression paddle. The skin-line enhancement artefact was seen in 19-46% of projections. None of the artefacts interfered with image interpretation. Two main artefacts commonly seen on CESM are rim and ripple artefacts. They do not hamper with image interpretation. It is important to be aware of them and prevent misinterpretation of these artefacts as real breast pathology. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  6. A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3 T

    International Nuclear Information System (INIS)

    Sreenivas, M.; Lowry, M.; Gibbs, P.; Pickles, M.; Turnbull, L.W.

    2007-01-01

    The quality of imaging obtained at high magnetic field strengths can be degraded by various artefacts due to conductive and dielectric effects, which leads to loss of signal. Various methods have been described and used to improve the quality of the image affected by such artefacts. In this article, we describe the construction and use of a simple solution that can be used to diminish artefacts due to conductive and dielectric effects in clinical imaging at 3 T field strength and thereby improve the diagnostic quality of the images obtained

  7. A simple solution for reducing artefacts due to conductive and dielectric effects in clinical magnetic resonance imaging at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Sreenivas, M. [Department of Radiology (Yorkshire Deanery-East), Hull Royal Infirmary, Anlaby Road, Hull HU3 2JZ (United Kingdom)]. E-mail: aprilsreenivas@hotmail.com; Lowry, M. [Centre for Magnetic Resonance Investigations, University of Hull, Hull Royal Infirmary, Anlaby Road, 1PR, Hull HU3 2JZ (United Kingdom); Gibbs, P. [Centre for Magnetic Resonance Investigations, University of Hull, Hull Royal Infirmary, Anlaby Road, 1PR, Hull HU3 2JZ (United Kingdom); Pickles, M. [Centre for Magnetic Resonance Investigations, University of Hull, Hull Royal Infirmary, Anlaby Road, 1PR, Hull HU3 2JZ (United Kingdom); Turnbull, L.W. [Centre for Magnetic Resonance Investigations, University of Hull, Hull Royal Infirmary, Anlaby Road, 1PR, Hull HU3 2JZ (United Kingdom)

    2007-04-15

    The quality of imaging obtained at high magnetic field strengths can be degraded by various artefacts due to conductive and dielectric effects, which leads to loss of signal. Various methods have been described and used to improve the quality of the image affected by such artefacts. In this article, we describe the construction and use of a simple solution that can be used to diminish artefacts due to conductive and dielectric effects in clinical imaging at 3 T field strength and thereby improve the diagnostic quality of the images obtained.

  8. Artefacts: Minecraft meets Collaborative Interactive Evolution

    DEFF Research Database (Denmark)

    Patrascu, Cristinel; Risi, Sebastian

    2016-01-01

    Procedural content generation has shown promise in a variety of different games. In this paper we introduce a new kind of game, called Artefacts, that combines a sandbox-like environment akin to Minecraft with the ability to interactively evolve unique three-dimensional building blocks. Artefacts...

  9. Multiple height calibration artefact for 3D microscopy

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carli, Lorenzo; Eriksen, Rasmus Solmer

    2011-01-01

    A novel artefact for calibration of the height in 3D microscopy is presented. The artefact comprises three steps having a common vertical axis, which allows z-coordinate calibration at different magnifications without requiring repositioning. The artefact is suitable for transferring traceability...... to 3D techniques at the micrometer and nanometer scale, e.g. 3D SEM, confocal microscopes etc. Two different series of samples were fabricated using EDM with three steps of 2–5–7μm, and 20–50–70μm, respectively, from a 3mm diameter carbide wire. The artefact steps were calibrated on a stylus instrument...

  10. Neutron activation analysis of artefacts

    International Nuclear Information System (INIS)

    Mohd Suhaimi Hamzah; Shamsiah Abd Rahman

    2004-01-01

    The paper discussed the utilization of neutron activation analysis in this field. NAA, an analytical technique which analyzing the elements in the sample without any chemical treatment. It is sensitive and accurate. Archaeological objects i.e. ceramics, historical building materials, metals, etc can be analyze with this technique. The analysis results were presented in form of characterization of the artefacts in chemical profiles, which can present the information of the origin of the artefacts as well as it originality. (Author)

  11. fMRI Artefact Rejection and Sleep Scoring Toolbox

    Directory of Open Access Journals (Sweden)

    Yves Leclercq

    2011-01-01

    Full Text Available We started writing the “fMRI artefact rejection and sleep scoring toolbox”, or “FAST”, to process our sleep EEG-fMRI data, that is, the simultaneous recording of electroencephalographic and functional magnetic resonance imaging data acquired while a subject is asleep. FAST tackles three crucial issues typical of this kind of data: (1 data manipulation (viewing, comparing, chunking, etc. of long continuous M/EEG recordings, (2 rejection of the fMRI-induced artefact in the EEG signal, and (3 manual sleep-scoring of the M/EEG recording. Currently, the toolbox can efficiently deal with these issues via a GUI, SPM8 batching system or hand-written script. The tools developed are, of course, also useful for other EEG applications, for example, involving simultaneous EEG-fMRI acquisition, continuous EEG eye-balling, and manipulation. Even though the toolbox was originally devised for EEG data, it will also gracefully handle MEG data without any problem. “FAST” is developed in Matlab as an add-on toolbox for SPM8 and, therefore, internally uses its SPM8-meeg data format. “FAST” is available for free, under the GNU-GPL.

  12. Superiority of triple-detector single-photon emission tomography over single- and dual-detector systems in the minimization of motion artefacts

    International Nuclear Information System (INIS)

    Nakajima, Kenichi; Taki, Junichi; Michigishi, Takatoshi; Tonami, Norihisa

    1998-01-01

    A patient motion-related artefact is one of the most important artefacts in single-photon emission tomography (SPET) imaging. This study evaluated the effect of the number and configuration of SPET detectors on motion artefacts. The following acquisition conditions were simulated based on original 360 projection images: (1) single-detector 180 rotation (S180), (2) a dual-detector rectangular (L-shaped) 180 acquisition (D180L), (3) dual-detector cameras mounted opposite each other with 360 acquisition (D360) and (4) triple-detector 360 acquisition (T360). The motion artefacts were introduced using a syringe and a myocardial phantom. Clinical cases with technetium-99m methoxyisobutylisonitrile and thallium-201 studies were analysed to confirm the validity of this phantom simulation. The effect of continuous alternate rotation acquisition and summing the projections on the reduction of motion artefacts was investigated in each model. The effect of motion depended on the number and the configuration of the SPET detectors. A 1-pixel (6.4 mm) motion in the S180, D180L and D360 models generated only slight artefacts, and a 2-pixel motion led to an apparent decrease in activity or created hot areas in the myocardium. On the other hand, a T360 rotation created few artefacts even with a 2-pixel motion of the last quarter of the projections. Despite the difference in attenuation with 201 Tl and 99m Tc, similar artefact patterns were observed with both radionuclides in selected patient model studies. Continuous alternate rotation could reduce artefacts caused by less than a 2-pixel motion. In conclusion, calculating the average of the sum of the projections of triple-detector 360 rotations with alternate rotation is the best method to minimize motion artefacts. This ''averaging'' effect of motion artefacts is a key to this simulation. (orig.)

  13. Value of monoenergetic dual-energy CT (DECT) for artefact reduction from metallic orthopedic implants in post-mortem studies.

    Science.gov (United States)

    Filograna, Laura; Magarelli, Nicola; Leone, Antonio; Guggenberger, Roman; Winklhofer, Sebastian; Thali, Michael John; Bonomo, Lorenzo

    2015-09-01

    The aim of this ex vivo study was to assess the performance of monoenergetic dual-energy CT (DECT) reconstructions to reduce metal artefacts in bodies with orthopedic devices in comparison with standard single-energy CT (SECT) examinations in forensic imaging. Forensic and clinical impacts of this study are also discussed. Thirty metallic implants in 20 consecutive cadavers with metallic implants underwent both SECT and DECT with a clinically suitable scanning protocol. Extrapolated monoenergetic DECT images at 64, 69, 88, 105, 120, and 130 keV and individually adjusted monoenergy for optimized image quality (OPTkeV) were generated. Image quality of the seven monoenergetic images and of the corresponding SECT image was assessed qualitatively and quantitatively by visual rating and measurements of attenuation changes induced by streak artefact. Qualitative and quantitative analyses showed statistically significant differences between monoenergetic DECT extrapolated images and SECT, with improvements in diagnostic assessment in monoenergetic DECT at higher monoenergies. The mean value of OPTkeV was 137.6 ± 4.9 with a range of 130 to 148 keV. This study demonstrates that monoenergetic DECT images extrapolated at high energy levels significantly reduce metallic artefacts from orthopedic implants and improve image quality compared to SECT examination in forensic imaging.

  14. Value of monoenergetic dual-energy CT (DECT) for artefact reduction from metallic orthopedic implants in post-mortem studies

    Energy Technology Data Exchange (ETDEWEB)

    Filograna, Laura [University of Zurich, Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, Zurich (Switzerland); Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Department of Radiological Sciences, Rome (Italy); Magarelli, Nicola; Leone, Antonio; Bonomo, Lorenzo [Catholic University of Rome, School of Medicine, University Hospital ' ' A. Gemelli' ' , Department of Radiological Sciences, Rome (Italy); Guggenberger, Roman; Winklhofer, Sebastian [University Hospital Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Thali, Michael John [University of Zurich, Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, Zurich (Switzerland)

    2015-09-15

    The aim of this ex vivo study was to assess the performance of monoenergetic dual-energy CT (DECT) reconstructions to reduce metal artefacts in bodies with orthopedic devices in comparison with standard single-energy CT (SECT) examinations in forensic imaging. Forensic and clinical impacts of this study are also discussed. Thirty metallic implants in 20 consecutive cadavers with metallic implants underwent both SECT and DECT with a clinically suitable scanning protocol. Extrapolated monoenergetic DECT images at 64, 69, 88, 105, 120, and 130 keV and individually adjusted monoenergy for optimized image quality (OPTkeV) were generated. Image quality of the seven monoenergetic images and of the corresponding SECT image was assessed qualitatively and quantitatively by visual rating and measurements of attenuation changes induced by streak artefact. Qualitative and quantitative analyses showed statistically significant differences between monoenergetic DECT extrapolated images and SECT, with improvements in diagnostic assessment in monoenergetic DECT at higher monoenergies. The mean value of OPTkeV was 137.6 ± 4.9 with a range of 130 to 148 keV. This study demonstrates that monoenergetic DECT images extrapolated at high energy levels significantly reduce metallic artefacts from orthopedic implants and improve image quality compared to SECT examination in forensic imaging. (orig.)

  15. Value of monoenergetic dual-energy CT (DECT) for artefact reduction from metallic orthopedic implants in post-mortem studies

    International Nuclear Information System (INIS)

    Filograna, Laura; Magarelli, Nicola; Leone, Antonio; Bonomo, Lorenzo; Guggenberger, Roman; Winklhofer, Sebastian; Thali, Michael John

    2015-01-01

    The aim of this ex vivo study was to assess the performance of monoenergetic dual-energy CT (DECT) reconstructions to reduce metal artefacts in bodies with orthopedic devices in comparison with standard single-energy CT (SECT) examinations in forensic imaging. Forensic and clinical impacts of this study are also discussed. Thirty metallic implants in 20 consecutive cadavers with metallic implants underwent both SECT and DECT with a clinically suitable scanning protocol. Extrapolated monoenergetic DECT images at 64, 69, 88, 105, 120, and 130 keV and individually adjusted monoenergy for optimized image quality (OPTkeV) were generated. Image quality of the seven monoenergetic images and of the corresponding SECT image was assessed qualitatively and quantitatively by visual rating and measurements of attenuation changes induced by streak artefact. Qualitative and quantitative analyses showed statistically significant differences between monoenergetic DECT extrapolated images and SECT, with improvements in diagnostic assessment in monoenergetic DECT at higher monoenergies. The mean value of OPTkeV was 137.6 ± 4.9 with a range of 130 to 148 keV. This study demonstrates that monoenergetic DECT images extrapolated at high energy levels significantly reduce metallic artefacts from orthopedic implants and improve image quality compared to SECT examination in forensic imaging. (orig.)

  16. Reduced artefacts and improved assessment of hyperintense brain lesions with BLADE MR imaging in patients with neurofibromatosis type 1

    Energy Technology Data Exchange (ETDEWEB)

    Kalle, Thekla von; Fabig-Moritz, Claudia; Mueller-Abt, Peter; Zieger, Michael; Winkler, Peter [Department of Paediatric Radiology, Stuttgart (Germany); Blank, Bernd [Haematology and Immunology, Department of Paediatric Oncology, Stuttgart (Germany); Wohlfarth, Katrin [Siemens Healthcare Sector, Erlangen (Germany)

    2009-11-15

    Assessment of small brain lesions in children is often compromised by pulsation, flow or movement artefacts. MRI with a rotating blade-like k-space covering (BLADE, PROPELLER) can compensate for these artefacts. We compared T2-weighted FLAIR images that were acquired with different k-space trajectories (conventional Cartesian and BLADE) to evaluate the impact of BLADE technique on the delineation of small or low-contrast brain lesions. The subject group comprised 26 children with neurofibromatosis type 1 (NF 1), who had been routinely scanned at 1.5 T for optic pathway gliomas with both techniques and who had the typical hyperintense brain lesions seen in NF 1. Four experienced radiologists retrospectively compared unlabelled 4-mm axial images with respect to the presence of artefacts, visibility of lesions, quality of contour and contrast. Both techniques were comparable in depicting hyperintense lesions as small as 2 mm independent of contrast and edge definition. Pulsation and movement artefacts were significantly less common with BLADE k-space trajectory. In 7 of 26 patients (27%), lesions and artefacts were rated as indistinguishable in conventional FLAIR, but not in BLADE FLAIR images. BLADE imaging significantly improved the depiction of lesions in T2-W FLAIR images due to artefact reduction especially in the posterior fossa. (orig.)

  17. Reduced artefacts and improved assessment of hyperintense brain lesions with BLADE MR imaging in patients with neurofibromatosis type 1

    International Nuclear Information System (INIS)

    Kalle, Thekla von; Fabig-Moritz, Claudia; Mueller-Abt, Peter; Zieger, Michael; Winkler, Peter; Blank, Bernd; Wohlfarth, Katrin

    2009-01-01

    Assessment of small brain lesions in children is often compromised by pulsation, flow or movement artefacts. MRI with a rotating blade-like k-space covering (BLADE, PROPELLER) can compensate for these artefacts. We compared T2-weighted FLAIR images that were acquired with different k-space trajectories (conventional Cartesian and BLADE) to evaluate the impact of BLADE technique on the delineation of small or low-contrast brain lesions. The subject group comprised 26 children with neurofibromatosis type 1 (NF 1), who had been routinely scanned at 1.5 T for optic pathway gliomas with both techniques and who had the typical hyperintense brain lesions seen in NF 1. Four experienced radiologists retrospectively compared unlabelled 4-mm axial images with respect to the presence of artefacts, visibility of lesions, quality of contour and contrast. Both techniques were comparable in depicting hyperintense lesions as small as 2 mm independent of contrast and edge definition. Pulsation and movement artefacts were significantly less common with BLADE k-space trajectory. In 7 of 26 patients (27%), lesions and artefacts were rated as indistinguishable in conventional FLAIR, but not in BLADE FLAIR images. BLADE imaging significantly improved the depiction of lesions in T2-W FLAIR images due to artefact reduction especially in the posterior fossa. (orig.)

  18. Influence of chest compression artefact on capnogram-based ventilation detection during out-of-hospital cardiopulmonary resuscitation.

    Science.gov (United States)

    Leturiondo, Mikel; Ruiz de Gauna, Sofía; Ruiz, Jesus M; Julio Gutiérrez, J; Leturiondo, Luis A; González-Otero, Digna M; Russell, James K; Zive, Dana; Daya, Mohamud

    2018-03-01

    Capnography has been proposed as a method for monitoring the ventilation rate during cardiopulmonary resuscitation (CPR). A high incidence (above 70%) of capnograms distorted by chest compression induced oscillations has been previously reported in out-of-hospital (OOH) CPR. The aim of the study was to better characterize the chest compression artefact and to evaluate its influence on the performance of a capnogram-based ventilation detector during OOH CPR. Data from the MRx monitor-defibrillator were extracted from OOH cardiac arrest episodes. For each episode, presence of chest compression artefact was annotated in the capnogram. Concurrent compression depth and transthoracic impedance signals were used to identify chest compressions and to annotate ventilations, respectively. We designed a capnogram-based ventilation detection algorithm and tested its performance with clean and distorted episodes. Data were collected from 232 episodes comprising 52 654 ventilations, with a mean (±SD) of 227 (±118) per episode. Overall, 42% of the capnograms were distorted. Presence of chest compression artefact degraded algorithm performance in terms of ventilation detection, estimation of ventilation rate, and the ability to detect hyperventilation. Capnogram-based ventilation detection during CPR using our algorithm was compromised by the presence of chest compression artefact. In particular, artefact spanning from the plateau to the baseline strongly degraded ventilation detection, and caused a high number of false hyperventilation alarms. Further research is needed to reduce the impact of chest compression artefact on capnographic ventilation monitoring. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner

    International Nuclear Information System (INIS)

    Slates, R.B.; Farahani, K.; Marsden, P.K.; Taylor, J.; Summers, P.E.; Williams, S.; Beech, J.

    1999-01-01

    We have assessed the possibility of artefacts that can arise in attempting to perform simultaneous positron emission tomography (PET) and magnetic resonance imaging (MRI) using a small prototype MR compatible PET scanner (McPET). In these experiments, we examine MR images for any major artefacts or loss in image quality due to inhomogeneities in the magnetic field, radiofrequency interference or susceptibility effects caused by operation of the PET system inside the MR scanner. In addition, possible artefacts in the PET images caused by the static and time-varying magnetic fields or radiofrequency interference from the MR system were investigated. Biological tissue and a T 2 -weighted spin echo sequence were used to examine susceptibility artefacts due to components of the McPET scanner (scintillator, optical fibres) situated in the MR field of view. A range of commonly used MR pulse sequences was studied while acquiring PET data to look for possible artefacts in either the PET or MR images. Other than a small loss in signal-to-noise using gradient echo sequences, there was no significant interaction between the two imaging systems. Simultaneous PET and MR imaging of simple phantoms was also carried out in different MR systems with field strengths ranging from 0.2 to 4.7 T. The results of these studies demonstrate that it is possible to acquire PET and MR images simultaneously, without any significant artefacts or loss in image quality, using our prototype MR compatible PET scanner. (author)

  20. Experiential Role of Artefacts in Cooperative Design

    NARCIS (Netherlands)

    Vyas, Dhaval; Heylen, Dirk K.J.; Nijholt, Antinus; van der Veer, Gerrit C.; Caroll, J.M.

    2009-01-01

    The role of material artefacts in supporting distributed and co-located work practices has been well acknowledged within the HCI and CSCW research. In this paper, we show that in addition to their ecological, coordinative and organizational support, artefacts also play an ‘experiential’ role. In

  1. Replica calibration artefacts for optical 3D scanning of micro parts

    DEFF Research Database (Denmark)

    De Chiffre, Leonardo; Carmignato, S.; Cantatore, Angela

    2009-01-01

    This work deals with development of calibration artefacts produced by using hard replica materials, achieving high quality geometrical reproduction of suitable reference artefacts, high stability, and high surface cooperativeness. An investigation was carried out using a replica material for dental...... applications to reproduce the geometry of a step artefact, a miniature step gauge, and a curve standard for optical measuring machines. The replica artefacts were calibrated using a tactile coordinate measuring machine and measured on two different optical scanners. Replication quality and applicability...... of the artefacts to verify the accuracy of optical measurements as well as thermal expansion coefficient and stability of the replica artefacts over time were documented....

  2. Leadership identity : using artefacts (and storytelling) to discover new insights.

    OpenAIRE

    Watton, Emma Louisa; Parry, Ken

    2016-01-01

    Artefacts are used in management education to reflect upon the experiences of participants. Story-telling has a leadership influence that is long recognised in the leadership literature. However, artefacts and story-telling have not been used concurrently in leadership and management development programmes. We used artefacts combined with story-telling to help participants understand their leadership identity. Louisa’s story and artefact are the basis of this research. We found that the story...

  3. Investigating effects of different artefact types on motor imagery BCI

    DEFF Research Database (Denmark)

    Frølich, Laura; Winkler, Irene; Muller, Klaus-Robert

    2015-01-01

    Artefacts in recordings of the electroencephalogram (EEG) are a common problem in Brain-Computer Interfaces (BCIs). Artefacts make it difficult to calibrate from training sessions, resulting in low test performance, or lead to artificially high performance when unintentionally used for BCI control...... that muscle, but not ocular, artefacts adversely affect BCI performance when all 119 EEG channels are used. Artefacts have little influence when using 48 centrally located EEG channels in a configuration previously found to be optimal....

  4. Indigenous african artefacts: Can they serve as tangible programming objects?

    CSIR Research Space (South Africa)

    Smith, Andrew C

    2010-05-01

    Full Text Available , African artefacts, Interaction design. 1. Introduction The aim of our research is to investigate the possible use of physical artefacts as tangible programming objects with the purpose of instilling an interest in programming amongst regional tribes... in Africa. Physical artefacts are hand-crafted objects made by community members. We envisage a simple computing system that derives its input from the manipulation of artefacts as opposed to the use of a keyboard and mouse. In order to do so...

  5. Organisational learning is crystallised into artefacts

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege

    1996-01-01

    In this note I understand organisational learning in terms of manifest crystallisation of collective experience into artefacts, and I attempt to integrate an engineering and an emancipatory perspective. A Danish music festival serves as an example.......In this note I understand organisational learning in terms of manifest crystallisation of collective experience into artefacts, and I attempt to integrate an engineering and an emancipatory perspective. A Danish music festival serves as an example....

  6. Assessing MRI susceptibility artefact through an indicator of image distortion

    Directory of Open Access Journals (Sweden)

    Illanes Alfredo

    2016-09-01

    Full Text Available Susceptibility artefacts in magnetic resonance imaging (MRI caused by medical devices can result in a severe degradation of the MR image quality. The quantification of susceptibility artefacts is regulated by the ASTM standard which defines a manual method to assess the size of an artefact. This means that the estimated artefact size can be user dependent. To cope with this problem, we propose an algorithm to automatically quantify the size of such susceptibility artefacts. The algorithm is based on the analysis of a 3D surface generated from the 2D MR images. The results obtained by the automatic algorithm were compared to the manual measurements performed by study participants. The results show that the automatic and manual measurements follow the same trend. The clear advantage of the automated algorithm is the absence of the inter- and intra-observer variability. In addition, the algorithm also detects the slice containing the largest artefact which was not the case for the manual measurements.

  7. Artefacts that talk

    DEFF Research Database (Denmark)

    Hasse, Cathrine

    2013-01-01

    The article takes up the notion of artefacts as tools and signs and discusses how socially assistive robots impact professional work life and professional identities as multistable active change agents. It argues for a multistable understanding of tools as signs, building on a combination of post...

  8. Metal artefact suppression at 3 T MRI: comparison of MAVRIC-SL with conventional fast spin echo sequences in patients with Hip joint arthroplasty

    International Nuclear Information System (INIS)

    Kretzschmar, Martin; Nardo, Lorenzo; Han, Misung M.; Heilmeier, Ursula; Sam, Craig; Joseph, Gabby B.; Krug, Roland; Link, Thomas M.; Koch, Kevin M.

    2015-01-01

    The aim of our study was to evaluate the clinical feasibility and diagnostic value of a new MRI metal artefact reduction pulse sequence called MAVRIC-SL in a 3 T MRI environment. Two MAVRIC-SL sequences obtained in 61 patients with symptomatic total hip replacement were compared with standard FSE-STIR sequences optimized for imaging around metal. Artefact size was measured on the slice of greatest extent. Image quality, fat saturation, image distortion, visibility of anatomical structures, and detectability of joint abnormalities were visually assessed and graded on qualitative scales. Differences between MAVRIC-SL and FSE sequences were tested with the Wilcoxon signed-rank test. MAVRIC-SL sequences at 3 T showed significantly smaller metal artefacts compared to FSE-STIR sequences (p < 0.0001). The general image quality of MAVRIC-SL sequences was reduced with regard to spatial resolution, noise and contrast (p = 0.001), and fat saturation (p < 0.0001). The reduction of artefact size and image distortion significantly improved visualization of joint anatomy (p < 0.0001) and diagnostic confidence regarding implant-associated abnormalities (p = 0.0075 to <0.0001). Although the image quality of MAVRIC-SL sequences is limited at 3 T, its clinical application is feasible and provides important additional diagnostic information for the workup of patients with symptomatic hip replacement through substantially reduced metal artefacts. (orig.)

  9. Metal artefact suppression at 3 T MRI: comparison of MAVRIC-SL with conventional fast spin echo sequences in patients with Hip joint arthroplasty

    Energy Technology Data Exchange (ETDEWEB)

    Kretzschmar, Martin; Nardo, Lorenzo; Han, Misung M.; Heilmeier, Ursula; Sam, Craig; Joseph, Gabby B.; Krug, Roland; Link, Thomas M. [University of California San Francisco, Musculoskeletal Quantitative Imaging Research Group, Department of Radiology and Biomedical Imaging, San Francisco, CA (United States); Koch, Kevin M. [Medical Collage of Wisconsin, Departments of Biophysics and Radiology, Milwaukee, WI (United States)

    2015-08-15

    The aim of our study was to evaluate the clinical feasibility and diagnostic value of a new MRI metal artefact reduction pulse sequence called MAVRIC-SL in a 3 T MRI environment. Two MAVRIC-SL sequences obtained in 61 patients with symptomatic total hip replacement were compared with standard FSE-STIR sequences optimized for imaging around metal. Artefact size was measured on the slice of greatest extent. Image quality, fat saturation, image distortion, visibility of anatomical structures, and detectability of joint abnormalities were visually assessed and graded on qualitative scales. Differences between MAVRIC-SL and FSE sequences were tested with the Wilcoxon signed-rank test. MAVRIC-SL sequences at 3 T showed significantly smaller metal artefacts compared to FSE-STIR sequences (p < 0.0001). The general image quality of MAVRIC-SL sequences was reduced with regard to spatial resolution, noise and contrast (p = 0.001), and fat saturation (p < 0.0001). The reduction of artefact size and image distortion significantly improved visualization of joint anatomy (p < 0.0001) and diagnostic confidence regarding implant-associated abnormalities (p = 0.0075 to <0.0001). Although the image quality of MAVRIC-SL sequences is limited at 3 T, its clinical application is feasible and provides important additional diagnostic information for the workup of patients with symptomatic hip replacement through substantially reduced metal artefacts. (orig.)

  10. The materiality of materials and artefacts used in science classrooms

    DEFF Research Database (Denmark)

    Cowie, Bronwen; Otrel-Cass, Kathrin; Moreland, Judy

    Material objects and artefacts receive limited attention in science education (Roehl, 2012) though they shape emerging interactions. This is surprising given science has material and a social dimensions (Pickering, 1995) whereby new knowledge develops as a consensus explanation of natural phenomena...... that is mediated significantly through materials and instruments used. Here we outline the ways teachers deployed material objects and artefacts by identifying their materiality to provide scenarios and resources (Roth, 2005) for interactions. Theoretical framework We use Ingold's (2011) distinction between...... materials as natural objects in this world and artefacts as manmade objects. We are aware that in a classroom material objects and artefacts shape, and are shaped by classroom practice through the way they selectively present scientific explanations. However, materials and artefacts have no intrinsic...

  11. 3D artefact for concurrent scale calibration in Computed Tomography

    DEFF Research Database (Denmark)

    Stolfi, Alessandro; De Chiffre, Leonardo

    2016-01-01

    A novel artefact for calibration of the scale in 3D X-ray Computed Tomography (CT) is presented. The artefact comprises a carbon fibre tubular structure on which a number of reference ruby spheres are glued. The artefact is positioned and scanned together with the workpiece inside the CT scanner...

  12. Possible artefacts in thin layer chromatography of tritium-labelled hydrocortisone

    International Nuclear Information System (INIS)

    Sofronie, E.

    1982-12-01

    Artefacts appearing in thin layer chromatography of tritium labelled hydrocortisone are reported. Evidences are presented that these artefacts cause misleading results concerning radiocheemical purity determiniation. Finally, it is reported a rapid and efficient chromatographic technique allowing the elimination of these artefacts and obtaining of an accurate value for radiochemical purity. (author)

  13. Reduction in respiratory motion artefacts on gadoxetate-enhanced MRI after training technicians to apply a simple and more patient-adapted breathing command

    International Nuclear Information System (INIS)

    Gutzeit, Andreas; Matoori, Simon; Weymarn, Constantin von; Reischauer, Carolin; Goyen, Matthias; Hergan, Klaus; Meissnitzer, Matthias; Forstner, Rosemarie; Froehlich, Johannes M.; Kolokythas, Orpheus; Soyka, Jan D.; Doert, Aleksis; Koh, Dow-Mu

    2016-01-01

    To investigate whether a trained group of technicians using a modified breathing command during gadoxetate-enhanced liver MRI reduces respiratory motion artefacts compared to non-trained technicians using a traditional breathing command. The gadoxetate-enhanced liver MR images of 30 patients acquired using the traditional breathing command and the subsequent 30 patients after training the technicians to use a modified breathing command were analyzed. A subgroup of patients (n = 8) underwent scans both by trained and untrained technicians. Images obtained using the traditional and modified breathing command were compared for the presence of breathing artefacts [respiratory artefact-based image quality scores from 1 (best) to 5 (non-diagnostic)]. There was a highly significant improvement in the arterial phase image quality scores in patients using the modified breathing command compared to the traditional one (P < 0.001). The percentage of patients with severe and extensive breathing artefacts in the arterial phase decreased from 33.3 % to 6.7 % after introducing the modified breathing command (P = 0.021). In the subgroup that underwent MRI using both breathing commands, arterial phase image quality improved significantly (P = 0.008) using the modified breathing command. Training technicians to use a modified breathing command significantly improved arterial phase image quality of gadoxetate-enhanced liver MRI. (orig.)

  14. Artefact specification, design, and production as a process of communication

    DEFF Research Database (Denmark)

    Galle, Per

    1999-01-01

    about communication as literal ‘transmission’ or ‘sharing’ of ideas. It is then explained how the initial artefact specification, the design representation, and ultimately the artefact itself can all be seen as symbolic expressions of ideas that are communicated, and it is shown how the conditions...... for the success of communication carry over to the artefact production process. The purpose of the analysis is to provide a conceptual background for the study of various aspects of artefact production, such as design, or the development of computer-based tools for collaborative design, product modelling...

  15. Reducing beam hardening effects and metal artefacts using Medipix3RX: With applications from biomaterial science

    CERN Document Server

    Rajendran, K; de Ruiter, N J A; Chernoglazov, A I; Panta, R K; Butler, A P H; Butler, P H; Bell, S T; Anderson, N G; Woodfield, T B F; Tredinnick, S J; Healy, J L; Bateman, C J; Aamir, R; Doesburg, R M N; Renaud, P F; Gieseg, S P; Smithies, D J; Mohr, J L; Mandalika, V B H; Opie, A M T; Cook, N J; Ronaldson, J P; Nik, S J; Atharifard, A; Clyne, M; Bones, P J; Bartneck, C; Grasset, R; Schleich, N; Billinghurst, M

    2014-01-01

    This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routine. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D reconstruction software and volume visualisation using a custom volume rendering software. Narrow high energy acquisition using the photon-processing detector revealed substantial reduction in beam hardening effects and metal artefacts.

  16. Comparison of two ring artefact removal filters used for neutron tomography reconstruction

    International Nuclear Information System (INIS)

    Vontobel, P.

    2007-01-01

    Full text of publication follows: The reduction of ring artefacts in transmission tomography reconstruction, by filtering sino-grams, is a common practice for most radiation modalities. Using simulated and measured neutron transmission data, an analysis of two ring artefact suppression schemes is given. The choice of the ring filtering parameters has to take the noise characteristics of the measured raw projection data into account. Introduction The appearance of ring artefacts in transmission tomography data is quite common. They are due to deficiencies in the measured projections and show as vertical lines in the sinogram representation of all projections of a single slice. A vertical line in the sinogram is due to a single pixel or a group of n pixels on the detector, which is less or more sensitive than the average pixel and shows even after flat-field correction. Most annoying ring artefacts are due to partly dead pixels, which cannot be identified easily on the projection images. Their effect only show in the sinogram or later on the reconstructed slice images. Therefore ring artefact mitigation starts with the analysis of sinogram images or analysis of reconstructed slices. Analysis of two ring filtering algorithms: The first ring filtering method sums first sinogram rows (i.e. over all angles) and divides it by the number of rows (ave) and generate a smoothed version of this sum (smoothing width 3,5,7,9 pixels). The difference diff = ave - smooth(ave) is then subtracted from each row. This is a very simple and efficient correction scheme. The second method relies on morphological filtering the sinogram i.e. using a combination of a morphological 'Top hat' and a 'Bot hat' operation on the data. A filtering threshold is determined depending on the number of detected lines in the sinogram. Summary and conclusion: Using simulated an measured neutron transmission data two ring filtering algorithms are evaluated. A careful choice of filtering parameters is

  17. Basic artefacts of diagnostic imaging by the magnetic resonance method

    International Nuclear Information System (INIS)

    Vitak, T.; Seidl, Z.; Obenberger, J.; Vaneckova, M.; Danes, J.; Krasensky, J.; Peterkova, V

    2000-01-01

    Artefacts in diagnostic imaging are defined as a geometric or anatomic misrepresentation of the reality by the image formed. The article deals with artefacts due to field and frequency shifts, in particular due to the water-fat chemical shift and due to magnetic susceptibility. The physical nature of the artefacts is explained and their diagnostic significance is discussed. (P.A.)

  18. GIS as an Artefact in Geography Education: Some Future Challenges

    DEFF Research Database (Denmark)

    Madsen, Lene Møller; Winsløw, Carl

    2007-01-01

    Geographers have always used a variety of physical artefacts e.g. a pluviometer, a map, or a globe as tools to perform their profession. Each of these artefacts has in different ways shaped our ways of being and becoming geographers. Not only have they shaped how we learn but also what we learn. ...... this artefact offers to education and teaching....

  19. Quality Enhancement and Nerve Fibre Layer Artefacts Removal in Retina Fundus Images by Off Axis Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Giancardo, Luca [ORNL; Meriaudeau, Fabrice [ORNL; Karnowski, Thomas Paul [ORNL; Li, Yaquin [University of Tennessee, Knoxville (UTK); Tobin Jr, Kenneth William [ORNL; Chaum, Edward [University of Tennessee, Knoxville (UTK)

    2011-01-01

    Retinal fundus images acquired with non-mydriatic digital fundus cameras are a versatile tool for the diagnosis of various retinal diseases. Because of the ease of use of newer camera models and their relative low cost, these cameras are employed worldwide by retina specialists to diagnose diabetic retinopathy and other degenerative diseases. Even with relative ease of use, the images produced by these systems sometimes suffer from reflectance artefacts mainly due to the nerve fibre layer (NFL) or other camera lens related reflections. We propose a technique that employs multiple fundus images acquired from the same patient to obtain a single higher quality image without these reflectance artefacts. The removal of bright artefacts, and particularly of NFL reflectance, can have great benefits for the reduction of false positives in the detection of retinal lesions such as exudate, drusens and cotton wool spots by automatic systems or manual inspection. If enough redundant information is provided by the multiple images, this technique also compensates for a suboptimal illumination. The fundus images are acquired in straightforward but unorthodox manner, i.e. the stare point of the patient is changed between each shot but the camera is kept fixed. Between each shot, the apparent shape and position of all the retinal structures that do not exhibit isotropic reflectance (e.g. bright artefacts) change. This physical effect is exploited by our algorithm in order to extract the pixels belonging to the inner layers of the retina, hence obtaining a single artefacts-free image.

  20. On what is made : instruments, products and natural kinds of artefacts

    NARCIS (Netherlands)

    Houkes, W.N.; Vermaas, P.E.; Franssen, M.; Kroes, P.; Reydon, T.A.C.; Vermaas, P.E.

    2014-01-01

    Debates in the metaphysics of artefacts typically start from the observation that technical artefacts result from intentional production and then focus immediately on the issue whether this ‘mind-dependence’ undermines claims that artefacts exist or come in natural or real kinds. We aim to add

  1. Reduction of artefacts caused by hip implants in CT-based attenuation-corrected PET images using 2-D interpolation of a virtual sinogram on an irregular grid

    NARCIS (Netherlands)

    Abdoli, Mehrsima; de Jong, Johan R.; Pruim, Jan; Dierckx, Rudi A. J. O.; Zaidi, Habib

    2011-01-01

    Purpose Metallic prosthetic replacements, such as hip or knee implants, are known to cause strong streaking artefacts in CT images. These artefacts likely induce over-or underestimation of the activity concentration near the metallic implants when applying CT-based attenuation correction of positron

  2. Emergent Artefacts of Ethnography and Processual Engagements of design

    DEFF Research Database (Denmark)

    Wallace, Jamie

    2012-01-01

    Relating to processes of design and creativity, the use of artefacts are contrasted between two different disciplines. Pointing to possible challenges, the study considers how collaborative innovation depends upon the interplay between entwined and emergent artefact worlds and their related skill...

  3. Artefacts and Troubleshooting. Appendix I

    Energy Technology Data Exchange (ETDEWEB)

    Busemann Sokole, E. [Department of Nuclear Medicine, Academic Medical Center, Amsterdam (Netherlands); Forwood, N. J. [Department of Nuclear Medicine, Royal North Shore Hospital, Sydney (Australia)

    2014-12-15

    Troubleshooting refers to the process of recognizing and identifying the cause of an artefact, a malfunction or a problem in an instrument. The problem could be immediately obvious, for example, the instrument does not work at all or a particular component stops working (such as the computer, the mechanism for whole body scanning or the automatic mechanism for collimator exchange). The malfunction could also be less obvious, and be recognized only by an abnormality in the expected result (such as the pattern formed by a defective photomultiplier tube (PMT) in the gamma camera clinical or quality control (QC) image or an unexpected calibration result in a radionuclide dose calibrator). Such an abnormality is generally referred to as an artefact, in particular, when observed in images.

  4. Explicating the Sustainable Design of Technical Artefacts

    DEFF Research Database (Denmark)

    Vissonova, Karina

    2016-01-01

    afforded by the properties of artefacts. The study is a conceptual analysis and as such belongs to the field of epistemology of design. It offers three contributions to the design discipline: (1) a proposition of the definition of the sustainable design kind; (2) a proposition of the concept of technical......Sustainable design of technical artefacts is referred to as if it were a kind of design with some specific characteristics. However, in design research and practice alike, there appears to be a lack of shared conceptions of what such a design might entail. Furthermore, we have no clear grounds...... for evaluating what makes the sustainable design solutions permissible. The lack of shared conceptions is largely due to ambiguities associated with the notion of sustainability. In response to these challenges, the aim of my study is to offer a definition of sustainable design of technical artefacts. I argue...

  5. The effect of magnetisation transfer contrast on cerebrospinal fluid on motion artefacts on fluid-attenuated inversion-recovery images

    International Nuclear Information System (INIS)

    Aprile, I.; Principi, M.; Ottaviano, P.; Scapeccia, M.

    2003-01-01

    We assessed possible advantages of the use of fluid-attenuated inversion-recovery (FLAIR) sequences with magnetisation-transfer contrast (MTC) over conventional FLAIR images. We carried out cranial MRI at 1 tesla on 50 patients with both sequences. In nine patients with multiple sclerosis (MS) we performed a quantitative comparison of the two sequences, looking at the contrast-to-noise ratio between lesions and normal white matter and counting the number of lesions shown using each method. A qualitative comparison on all patients consisted of the analysis of the appearance of the normal parenchyma, of any lesions, and of artefacts, with particular reference to cerebrospinal fluid (CSF) motion artefacts. The quantitative analysis showed no meaningful difference between the two sequences. The cerebral parenchyma and lesions appeared substantially the same with both techniques. With FLAIR MTC there was a clear, and consistent reduction in CSF motion artefacts. FLAIR MTC sequences can usefully be used in place of the conventional sequence at 1 tesla. (orig.)

  6. X-ray CT high-density artefact suppression in the presence of bones

    Energy Technology Data Exchange (ETDEWEB)

    Wei Jikun [School of Health Sciences, 550 Stadium Mall Drive, West Lafayette, IN 47907-2051 (United States); Chen Laigao [BioImaging Center of Emphasis, Pfizer Global Research and Development, 2800 Plymouth RD, Ann Arbor, MI 48105 (United States); Sandison, George A [School of Health Sciences, 550 Stadium Mall Drive, West Lafayette, IN 47907-2051 (United States); Liang Yun [Department of Radiology, Indiana University Medical School, Indianapolis, IN 46202 (United States); Xu, Lisa X [School of Mechanical Engineering, 585 Purdue Mall, West Lafayette, IN 47907-2040 (United States)

    2004-12-21

    This paper presents a novel method of reducing x-ray CT high-density artefacts generated by metal objects when abundant bone structures are present in the region of interest. This method has an advantage over previously proposed methods since it heavily suppresses the metal artefacts without introducing extra bone artefacts. The method of suppression requires that bone pixels are isolated and segmented by thresholding. Then artificial CT numbers are assigned to the bone pixels so that their projection profiles are smooth and thus can be properly simulated by a polynomial interpolation. The projection profile of the metal object is then removed to fully suppress the artefacts. The resulting processed profile is fed to a reconstruction routine and the previously preserved bone pixels added back. The new method utilizes two important features of the CT image with metal artefacts: (a) metal and bone pixels are not severely affected by the high-density artefacts and (b) the high-density artefacts can be located in specific projection channels in the profile domain, although they are spread out in the image domain. This suppression method solves the problem of CT image artefacts arising from metal objects in the body. It has the potential to greatly improve diagnostic CT imaging in the presence of these objects and treatment planning that utilizes CT for patients with metal applicators (e.g., brachytherapy for cervix cancer and prostate cryotherapy)

  7. X-ray CT high-density artefact suppression in the presence of bones

    International Nuclear Information System (INIS)

    Wei Jikun; Chen Laigao; Sandison, George A; Liang Yun; Xu, Lisa X

    2004-01-01

    This paper presents a novel method of reducing x-ray CT high-density artefacts generated by metal objects when abundant bone structures are present in the region of interest. This method has an advantage over previously proposed methods since it heavily suppresses the metal artefacts without introducing extra bone artefacts. The method of suppression requires that bone pixels are isolated and segmented by thresholding. Then artificial CT numbers are assigned to the bone pixels so that their projection profiles are smooth and thus can be properly simulated by a polynomial interpolation. The projection profile of the metal object is then removed to fully suppress the artefacts. The resulting processed profile is fed to a reconstruction routine and the previously preserved bone pixels added back. The new method utilizes two important features of the CT image with metal artefacts: (a) metal and bone pixels are not severely affected by the high-density artefacts and (b) the high-density artefacts can be located in specific projection channels in the profile domain, although they are spread out in the image domain. This suppression method solves the problem of CT image artefacts arising from metal objects in the body. It has the potential to greatly improve diagnostic CT imaging in the presence of these objects and treatment planning that utilizes CT for patients with metal applicators (e.g., brachytherapy for cervix cancer and prostate cryotherapy)

  8. Radiocarbon dating of iron artefacts

    Energy Technology Data Exchange (ETDEWEB)

    Cresswell, R. [Australian National Univ., Canberra, ACT (Australia). Dept. of Nuclear Physics

    1997-12-31

    Iron artefacts are generally dated by association or on stylistic grounds. This may not give a true indication of the date of manufacture, or may not be possible if the piece is out of context, ambiguous in style, or a copy. Obtaining a direct date on the artefact would be preferable. During the processes of manufacture, carbon is incorporated into the iron from the fuel source. If the fuel is of a material containing contemporaneous carbon, i.e. has an ambient radiocarbon signature, e.g. charcoal, then we may reliably radiocarbon date the artefact by extracting this carbon. Care must be taken, however, to ensure that re-working has not introduced multiple sources of carbon that would give an erroneous date. Detailed chemical analysis must precede radiocarbon analysis. Sample size is determined by carbon content, and before the advent of accelerator mass spectrometry, several tens of grams of carbon were required for radiocarbon dating (van der Merwe, 1969), prohibiting this method except for high-carbon cast-irons and bulk samples, e.g. caches of nails. AMS permits the analysis of sub-gram pieces of iron (Cresswell, 1991), thereby permitting the analysis of museum pieces with only minimal loss of material, and small fragments of iron recovered from archaeological sites. A few examples are given to illustrate these points. Paper no. 41; Extended abstract. 6 refs.

  9. Radiocarbon dating of iron artefacts

    International Nuclear Information System (INIS)

    Cresswell, R.

    1997-01-01

    Iron artefacts are generally dated by association or on stylistic grounds. This may not give a true indication of the date of manufacture, or may not be possible if the piece is out of context, ambiguous in style, or a copy. Obtaining a direct date on the artefact would be preferable. During the processes of manufacture, carbon is incorporated into the iron from the fuel source. If the fuel is of a material containing contemporaneous carbon, i.e. has an ambient radiocarbon signature, e.g. charcoal, then we may reliably radiocarbon date the artefact by extracting this carbon. Care must be taken, however, to ensure that re-working has not introduced multiple sources of carbon that would give an erroneous date. Detailed chemical analysis must precede radiocarbon analysis. Sample size is determined by carbon content, and before the advent of accelerator mass spectrometry, several tens of grams of carbon were required for radiocarbon dating (van der Merwe, 1969), prohibiting this method except for high-carbon cast-irons and bulk samples, e.g. caches of nails. AMS permits the analysis of sub-gram pieces of iron (Cresswell, 1991), thereby permitting the analysis of museum pieces with only minimal loss of material, and small fragments of iron recovered from archaeological sites. A few examples are given to illustrate these points

  10. The effects of misinterpretation of an artefact on multidetector row CT scans in children

    Energy Technology Data Exchange (ETDEWEB)

    Du Plessis, Anne-Marie; Theron, Salomine; Andronikou, Savvas [University of Stellenbosch, Radiology Department, Tygerberg Hospital, Cape Town (South Africa)

    2009-02-15

    Artefacts reflect problems with radiographic technique rather than true pathology. These may be misinterpreted as pathology with serious consequences. An artefact caused such problems in one paediatric imaging department. To determine the incidence, and consequences of misinterpretation, of a CT artefact in a paediatric imaging department. A retrospective review of images and reports of paediatric CT scans over a set period with a known artefact was performed. Reports were correlated with reviewers' evaluation of the presence of artefact and reviewed for correct identification of artefact, misinterpretation as pathology, and action taken as a result. A total of 74 CT scans had been performed over the study period and an artefact detected by reviewers on 32 (43%). Six (18.75%) of these were misinterpreted as pathology, of which three (9.4%) were reported as tuberculous granulomas, two (6.2%) as haemorrhages and one (3.1%) as an unknown hyperdensity. Two patients (6.2%) had subsequent MRI studies performed, and treatment for tuberculosis was continued in one patient (3.1%). No initial report identified the artefact. One-fifth of the scans with the artefact were misinterpreted as pathology and half of these misinterpretations led to further action. Artefacts result in false diagnoses and unnecessary investigations; vigilance is needed. (orig.)

  11. Partial volume and aliasing artefacts in helical cone-beam CT

    International Nuclear Information System (INIS)

    Zou Yu; Sidky, Emil Y; Pan, Xiaochuan

    2004-01-01

    A generalization of the quasi-exact algorithms of Kudo et al (2000 IEEE Trans. Med. Imaging 19 902-21) is developed that allows for data acquisition in a 'practical' frame for clinical diagnostic helical, cone-beam computed tomography (CT). The algorithm is investigated using data that model nonlinear partial volume averaging. This investigation leads to an understanding of aliasing artefacts in helical, cone-beam CT image reconstruction. An ad hoc scheme is proposed to mitigate artefacts due to the nonlinear partial volume and aliasing artefacts

  12. The role of action knowledge in the comprehension of artefacts - a PET study

    DEFF Research Database (Denmark)

    Gerlach, Christian; Law, Ian; Gade, Anders

    2002-01-01

    and two naming tasks divided by category (natural objects vs artefacts). The left PMv (BA 6/44) was more activated by the categorization task for artefacts than by the categorization task for natural objects and the naming task for artefacts. However, the left PMv was not associated with the contrast......Activation of the left ventral premotor cortex (PMv) has in previous imaging studies been associated with the processing of visually presented artefacts. It has been suggested that this activation reflects processing of action knowledge and that action knowledge contributes to the comprehension...... of artefacts. The purpose of the present study was to test whether activation of the left PMv is common for all tasks involving the comprehension of artefacts or whether it is task specific. This was done by comparing performance and regional cerebral blood flow (rCBF) associated with two categorization tasks...

  13. Adaptive EMG noise reduction in ECG signals using noise level approximation

    Science.gov (United States)

    Marouf, Mohamed; Saranovac, Lazar

    2017-12-01

    In this paper the usage of noise level approximation for adaptive Electromyogram (EMG) noise reduction in the Electrocardiogram (ECG) signals is introduced. To achieve the adequate adaptiveness, a translation-invariant noise level approximation is employed. The approximation is done in the form of a guiding signal extracted as an estimation of the signal quality vs. EMG noise. The noise reduction framework is based on a bank of low pass filters. So, the adaptive noise reduction is achieved by selecting the appropriate filter with respect to the guiding signal aiming to obtain the best trade-off between the signal distortion caused by filtering and the signal readability. For the evaluation purposes; both real EMG and artificial noises are used. The tested ECG signals are from the MIT-BIH Arrhythmia Database Directory, while both real and artificial records of EMG noise are added and used in the evaluation process. Firstly, comparison with state of the art methods is conducted to verify the performance of the proposed approach in terms of noise cancellation while preserving the QRS complex waves. Additionally, the signal to noise ratio improvement after the adaptive noise reduction is computed and presented for the proposed method. Finally, the impact of adaptive noise reduction method on QRS complexes detection was studied. The tested signals are delineated using a state of the art method, and the QRS detection improvement for different SNR is presented.

  14. Exploring preferences and non-use values for hidden archaeological artefacts

    DEFF Research Database (Denmark)

    Lundhede, Thomas; Bille, Trine; Hasler, Berit

    2013-01-01

    This paper presents a choice experiment study of a proposed wetland restorationproject which aims to preserve archaeological artefacts from Stone Age villages which are presently buried within the topsoil. Wetland restoration can avoid destruction of the artefacts due to agricultural cultivation...

  15. X-ray CT high-density artefact suppression in cryosurgery

    International Nuclear Information System (INIS)

    Wei Jikun; Sandison, George A; Chen Laigao; Liang Yun; Xu, Lisa X

    2002-01-01

    Advantages of x-ray CT for imaging guidance of cryosurgery include 3D visualization of frozen and unfrozen tissue and calibration of temperature in the tissue water-ice interface (0-10 deg. C) to Hounsfield units. However, use of x-ray CT images and their thermal calibration can be compromised by the cryoprobes generating high-density streak artefacts. A new subtraction technique for artefact suppression is proposed and tested in prostate cryosurgery simulations. By subtracting the measured CT x-ray projection profile without cryoprobes from the profile with cryoprobes plus iceballs, one obtains the combined profile of the cryoprobes and a low value background. Polynomial interpolation to obtain the background profile allows its addition to the original profile without probes. The result may then be fed to a conventional filtered back-projection routine to reconstruct the probe-free image. Finally the cryoprobe pixels in the originally constructed image with probes and iceballs are added back to the probe-free image to get the final artefact-suppressed image. The major advantage of this subtraction technique is that it can successfully suppress the high-density artefacts in bone-abundant body regions such as the pelvis. X-ray CT images of cryoprobe arrays in a homogeneous gelatin phantom and the pelvic region of an anthropomorphic Rando phantom containing a human skeleton were generated. After suppression, cryoprobe metal artefact streaks are reduced and visualization of the positions and dimensions of the cryoprobes are well preserved. (note)

  16. Mapping SOA Artefacts onto an Enterprise Reference Architecture Framework

    Science.gov (United States)

    Noran, Ovidiu

    Currently, there is still no common agreement on the service-Oriented architecture (SOA) definition, or the types and meaning of the artefacts involved in the creation and maintenance of an SOA. Furthermore, the SOA image shift from an infrastructure solution to a business-wide change project may have promoted a perception that SOA is a parallel initiative, a competitor and perhaps a successor of enterprise architecture (EA). This chapter attempts to map several typical SOA artefacts onto an enterprise reference framework commonly used in EA. This is done in order to show that the EA framework can express and structure most of the SOA artefacts and therefore, a framework for SOA could in fact be derived from an EA framework with the ensuing SOA-EA integration benefits.

  17. Technical functions : a drawbridge between the intentional and structural nature of technical artefacts

    NARCIS (Netherlands)

    Vermaas, P.E.; Houkes, W.N.

    2006-01-01

    In this paper we present an action-theoretic account of artefact using and designing and describe our ICE-theory of function ascriptions to technical artefacts. By means of this account and theory we analyse the thesis of the dual nature of technical artefacts according to which descriptions of

  18. Some image artefacts in non-contact mode force microscopy

    International Nuclear Information System (INIS)

    Dinte, B.P.; Watson, G.S.; Dobson, J.F.; Myhra, S.

    1996-01-01

    Full text: Non-contact mode Atomic Force Microscopy (AFM), performed in air, of two-dimensional hexagonal close-packed (2DHCP) layers of 200 nm diameter polystyrene spheres yields images containing artefacts ('ghost spheres') at layer edges and vacancy sites. The origin of these artefacts is clearly not the simple convolution of the tip and sample geometries, but must be the interaction between them. A computer program was written to simulate the experimental contours, assuming that the only force between the tip and the sample is the van der Waals (dispersion) force, and that the contours traced by the AFM tip are those of constant force derivative. The energy was calculated by integrating R -6 over the volumes of the tip and the sample, with a (constant) arbitrary scaling factor. The experimental contours were reproduced by the simulations, except for the 'ghost' artefacts. The assumption that there is only a dispersion force is thus incorrect. The experiments were performed in air, so that all surfaces were coated by a layer of adsorbed moisture. It is proposed that meniscus forces may be the origin of the artefacts

  19. How artefacts influence our actions

    NARCIS (Netherlands)

    Pols, A.J.K.

    2013-01-01

    Artefacts can influence our actions in several ways. They can be instruments, enabling and facilitating actions, where their presence affects the number and quality of the options for action available to us. They can also influence our actions in a morally more salient way, where their presence

  20. ARTEFACT MOBILE DATA MODEL TO SUPPORT CULTURAL HERITAGE DATA COLLECTION AND INTERPRETATION

    Directory of Open Access Journals (Sweden)

    Z. S. Mohamed-Ghouse

    2012-07-01

    Full Text Available This paper discusses the limitation of existing data structures in mobile mapping applications to support archaeologists to manage the artefact (any object made or modified by a human culture, and later recovered by an archaeological endeavor details excavated at a cultural heritage site. Current limitations of data structure in the mobile mapping application allow archeologist to record only one artefact per test pit location. In reality, more than one artefact can be excavated from the same test pit location. A spatial data model called Artefact Mobile Data Model (AMDM was developed applying existing Relational Data Base Management System (RDBMS technique to overcome the limitation. The data model was implemented in a mobile database environment called SprintDB Pro which was in turn connected to ArcPad 7.1 mobile mapping application through Open Data Base Connectivity (ODBC. In addition, the design of a user friendly application built on top of AMDM to interpret and record the technology associated with each artefact excavated in the field is also discussed in the paper. In summary, the paper discusses the design and implementation of a data model to facilitate the collection of artefacts in the field using integrated mobile mapping and database approach.

  1. An atlas of artefacts: a teaching tool for scintillation camera quality control

    International Nuclear Information System (INIS)

    Busemann Sokole, E.; Graham, L.S.; Todd-Pokropek, A.; Wegst, A.; Robilotta, C.C.

    2002-01-01

    Aim: Evaluating results from quality control tests and recognizing possible artefacts in clinical images requires an insight into typical and atypical images and quantitative results. Learning to recognize what is acceptable requires access to different examples, and knowledge of underlying principles of image production. An atlas of image artefacts has been assembled to assist with interpreting quality control tests and recognizing artefacts in clinical images. The project was initiated and supported by the International Atomic Energy Agency (IAEA). Methods: The artefact atlas was developed and written by the first author of this abstract, based on images and information submitted by nuclear medicine users from around the world. Each image artefact example includes an accompanying descriptive text comprising a brief description of the data acquisition, radionuclide/radiopharmaceutical, circumstances under which the image was produced; results describing the images and subsequent conclusions; comments, as appropriate, giving guidelines for trouble shooting and follow-up; and, occasional literature references. The images supplied were mostly hardcopy results on film or paper. All images were digitized into JPEG format for inclusion into a digital document. Most examples were contained on one page. The atlas was reviewed by an international group of experts. Results: A total of about 250 examples from 26 centres in 16 countries were included. The examples are grouped into 6 sections: planar, SPECT, whole body, camera/computer interface, environment/radioactivity, and display/hardcopy. The atlas includes normal results, results from poor adjustment of the camera system, poor results obtained at acceptance testing, artefacts due to system malfunction, and artefacts due to environmental situations. Some image patterns are generic, others specific to system design. Results from different camera systems, as well as new and old generation systems have been included

  2. Computer Simulation of Multidimensional Archaeological Artefacts

    Directory of Open Access Journals (Sweden)

    Vera Moitinho de Almeida

    2013-11-01

    Full Text Available The main purpose of this ongoing research is to understand possible function(s of archaeological artefacts through Reverse Engineering processes. In addition, we intend to provide new data, as well as possible explications of the archaeological record according to what it expects about social activities and working processes, by simulating the potentialities of such actions in terms of input-output relationships. Our project focuses on the Neolithic lakeside site of La Draga (Banyoles, Catalonia. In this presentation we will begin by providing a clear overview of the major guidelines used to capture and process 3D digital data of several wooden artefacts. Then, we shall present the use of semi-automated relevant feature extractions. Finally, we intend to share preliminary computer simulation issues.

  3. Reducing the effects of metal artefact using high keV monoenergetic reconstruction of dual energy CT (DECT) in hip replacements

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Mark [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Norwich Radiology Academy, Norwich (United Kingdom); Reid, Karen [Norfolk and Norwich University Hospital, Norwich (United Kingdom); Toms, Andoni P. [Norfolk and Norwich University Hospital and University of East Anglia, Norwich (United Kingdom)

    2013-02-15

    The aim of this study was to determine whether high keV monoenergetic reconstruction of dual energy computed tomography (DECT) could be used to overcome the effects of beam hardening artefact that arise from preferential deflection of low energy photons. Two phantoms were used: a Charnley total hip replacement set in gelatine and a Catphan 500. DECT datasets were acquired at 100, 200 and 400 mA (Siemens Definition Flash, 100 and 140 kVp) and reconstructed using a standard combined algorithm (1:1) and then as monoenergetic reconstructions at 10 keV intervals from 40 to 190 keV. Semi-automated segmentation with threshold inpainting was used to obtain the attenuation values and standard deviation (SD) of the streak artefact. High contrast line pair resolution and background noise were assessed using the Catphan 500. Streak artefact is progressively reduced with increasing keV monoenergetic reconstructions. Reconstruction of a 400 mA acquisition at 150 keV results in reduction in the volume of streak artefact from 65 cm{sup 3} to 17 cm{sup 3} (74 %). There was a decrease in the contrast to noise ratio (CNR) at higher tube voltages, with the peak CNR seen at 70-80 keV. High contrast spatial resolution was maintained at high keV values. Monoenergetic reconstruction of dual energy CT at increasing theoretical kilovoltages reduces the streak artefact produced by beam hardening from orthopaedic prostheses, accompanied by a modest increase in heterogeneity of background image attenuation, and decrease in contrast to noise ratio, but no deterioration in high contrast line pair resolution. (orig.)

  4. Intergranular failure of roman silver artefacts

    Czech Academy of Sciences Publication Activity Database

    Vaníčková, J.; Děd, J.; Bartuška, Pavel; Lejček, Pavel

    567-568, - (2007), s. 213-216 ISSN 0255-5476 Institutional research plan: CEZ:AV0Z10100520 Keywords : silver embrittlement * archaeological artefacts * XRD Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 0.399, year: 2005

  5. Artefact biography 2.0 : the information value of corroded archaeological bronzes

    NARCIS (Netherlands)

    Nienhuis, J.

    2017-01-01

    The different phases in the life of archaeological objects can be described by artefact biography. This dissertation defines an updated version: artefact biography 2.0, and the life phases of Early Iron Age bronze studs from Oss-Zevenbergen, the Netherlands, are elaborated. Throughout the thesis,

  6. Phase-processing as a tool for speckle reduction in pulse-echo images

    DEFF Research Database (Denmark)

    Healey, AJ; Leeman, S; Forsberg, F

    1991-01-01

    . Traditional speckle reduction procedures regard speckle correction as a stochastic process and trade image smoothing (resolution loss) for speckle reduction. Recently, a new phase acknowledging technique has been proposed that is unique in its ability to correct for speckle interference with no image......Due to the coherent nature of conventional ultrasound medical imaging systems interference artefacts occur in pulse echo images. These artefacts are generically termed 'speckle'. The phenomenon may severely limit low contrast resolution with clinically relevant information being obscured...

  7. The radiographic image: A cultural artefact?

    International Nuclear Information System (INIS)

    Strudwick, Ruth M.

    2014-01-01

    This article looks at the role of the radiographic images produced by diagnostic radiographers. An ethnographic study of the workplace culture in one diagnostic imaging department was undertaken using participant observation for four months and semi-structured interviews with ten key informants. One of the key themes; that of the radiographic image as a cultural artefact, is explored in this article. The radiographic image is a cultural artefact which radiographers are protective of and take ownership of. Radiographers are conscious of the quality of their images and the images are an important aspect of their work. Radiographers take criticism of their images personally. The radiographic image is a record of the interaction that occurs between the radiographer and the patient. The way in which radiographic images are viewed, used and judged is an important aspect of the role of diagnostic radiographer

  8. THE A (H1N1 INFLUENZA. SYMBOLIC DIMENSIONS OF A PANDEMIC ARTEFACT

    Directory of Open Access Journals (Sweden)

    Andrés G. Seguel

    2013-01-01

    Full Text Available The aim of the present paper is to present the symbolic features that are exposed by the concept of artefact in the context of a pandemic alarm, such as the A (H1N1 influenza. The symbolic qualities entailed by the notion of artefact are well-known within the Social Sciences: Sociology, Anthropology, Archaeology, and Linguistics. The artefact is basically not an object, but an action aimed at designing, simulating or creating a simile by means of material, technological or linguistic structures. The purpose of the present work is to unveil the symbolic dimensions that are activated by the A (H1N1 influenza as a Pandemic Artefact: a the assumption of separating information from matter; b the need for a material support to enable the exchange; c the sociological reflexivity of the artefact and its agency; d the arbitrariness of its social use, that detaches it from the design as intention.

  9. Artefacts in geometric phase analysis of compound materials

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Jonathan J.P., E-mail: j.j.p.peters@warwick.ac.uk [Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL (United Kingdom); Beanland, Richard; Alexe, Marin [Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL (United Kingdom); Cockburn, John W.; Revin, Dmitry G.; Zhang, Shiyong Y. [Department of Physics and Astronomy, University of Sheffield, Hounsfield Road, Sheffield S3 7RH (United Kingdom); Sanchez, Ana M., E-mail: a.m.sanchez@warwick.ac.uk [Department of Physics, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL (United Kingdom)

    2015-10-15

    The geometric phase analysis (GPA) algorithm is known as a robust and straightforward technique that can be used to measure lattice strains in high resolution transmission electron microscope (TEM) images. It is also attractive for analysis of aberration-corrected scanning TEM (ac-STEM) images that resolve every atom column, since it uses Fourier transforms and does not require real-space peak detection and assignment to appropriate sublattices. Here it is demonstrated that, in ac-STEM images of compound materials with compositionally distinct atom columns, an additional geometric phase is present in the Fourier transform. If the structure changes from one area to another in the image (e.g. across an interface), the change in this additional phase will appear as a strain in conventional GPA, even if there is no lattice strain. Strategies to avoid this pitfall are outlined. - Highlights: • GPA is shown to produce incorrect strains when applied to images of compound materials. • A mathematical description is laid out for why GPA can produce artefacts. • The artefact is demonstrated using experimental and simulated data. • A ‘rule’ is set to avoid this artefact in GPA.

  10. Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.

    Science.gov (United States)

    McQuaid, Sarah J; Hutton, Brian F

    2008-06-01

    Respiratory motion during myocardial perfusion imaging can cause artefacts in both positron emission tomography (PET) and single-photon emission computed tomography (SPECT) images when mismatches between emission and transmission datasets arise. In this study, artefacts from different breathing motions were quantified in both modalities to assess key factors in attenuation-correction accuracy. Activity maps were generated using the NURBS-based cardiac-torso phantom for different respiratory cycles, which were projected, attenuation-corrected and reconstructed to form PET and SPECT images. Attenuation-correction was performed with maps at mismatched respiratory phases to observe the effect on the left-ventricular myocardium. Myocardial non-uniformity was assessed in terms of the standard deviation in scores obtained from the 17-segment model and changes in uniformity were compared for each mismatch and modality. Certain types of mismatch led to artefacts and corresponding increases in the myocardial non-uniformity. For each mismatch in PET, the increases in non-uniformity relative to an artefact-free image were as follows: (a) cardiac translation mismatch, 84% +/- 11%; (b) liver mismatch, 59% +/- 10%, (c) lung mismatch from diaphragm contraction, 28% +/- 8%; and (d) lung mismatch from chest-wall motion, 6% +/- 7%. The corresponding factors for SPECT were (a) 61% +/- 8%, (b) 34% +/- 8%, (c) -2% +/- 7)% and (d) -4% +/- 6%. Attenuation-correction artefacts were seen in PET and SPECT images, with PET being more severely affected. The most severe artefacts were produced from mismatches in cardiac and liver position, whereas lung mismatches were less critical. Both cardiac and liver positions must, therefore, be correctly matched during attenuation correction.

  11. Augmenting Everyday Artefacts to Support Social Interaction Among Senior Peers

    DEFF Research Database (Denmark)

    Nazzi, Elena; Sokoler, Tomas

    2015-01-01

    Novel technological possibilities emerge when tangible and social computing come together. This paper explores the potential of such technology when designing for seniors and their social interaction. Our research is guided by the concept of twitterIDo, which is to make seniors’ everyday activities...... and displays designed to start a dialogue with the seniors on how twitterIDo-technology may fit into their everyday situations. Our findings point out how augmented everyday artefacts can make a positive difference when designing technology in a domain such the one of seniors’ and their social interaction...... more visible by augmenting everyday artefacts to communicate the ongoing activity they are used for. We engaged a local community of seniors in a living lab to explore the possibilities of twitterIDo in real life situations. This paper presents a series of interactive prototypes of everyday artefacts...

  12. Electrically evoked compound action potentials artefact rejection by independent component analysis: procedure automation.

    Science.gov (United States)

    Akhoun, Idrick; McKay, Colette; El-Deredy, Wael

    2015-01-15

    Independent-components-analysis (ICA) successfully separated electrically-evoked compound action potentials (ECAPs) from the stimulation artefact and noise (ECAP-ICA, Akhoun et al., 2013). This paper shows how to automate the ECAP-ICA artefact cancellation process. Raw-ECAPs without artefact rejection were consecutively recorded for each stimulation condition from at least 8 intra-cochlear electrodes. Firstly, amplifier-saturated recordings were discarded, and the data from different stimulus conditions (different current-levels) were concatenated temporally. The key aspect of the automation procedure was the sequential deductive source categorisation after ICA was applied with a restriction to 4 sources. The stereotypical aspect of the 4 sources enables their automatic classification as two artefact components, a noise and the sought ECAP based on theoretical and empirical considerations. The automatic procedure was tested using 8 cochlear implant (CI) users and one to four stimulus electrodes. The artefact and noise sources were successively identified and discarded, leaving the ECAP as the remaining source. The automated ECAP-ICA procedure successfully extracted the correct ECAPs compared to standard clinical forward masking paradigm in 22 out of 26 cases. ECAP-ICA does not require extracting the ECAP from a combination of distinct buffers as it is the case with regular methods. It is an alternative that does not have the possible bias of traditional artefact rejections such as alternate-polarity or forward-masking paradigms. The ECAP-ICA procedure bears clinical relevance, for example as the artefact rejection sub-module of automated ECAP-threshold detection techniques, which are common features of CI clinical fitting software. Copyright © 2014. Published by Elsevier B.V.

  13. Fitts' law as a design artefact

    DEFF Research Database (Denmark)

    Bertelsen, Olav Wedege

    1994-01-01

    Fitts' law is described and discussed as an example of use of theory in human-computer interaction design. The dichotomy between academic theory and applied theory is rejected and replaced by a radical pragmatic notion of theories as design artefacts. Different roles of theory in design...

  14. EXPLOITING MIRRORS IN 3D RECONSTRUCTION OF SMALL ARTEFACTS

    Directory of Open Access Journals (Sweden)

    G. Kontogianni

    2018-05-01

    Full Text Available 3D reconstruction of small artefacts is very significant in order to capture the details of the whole object irrespective of the documentation method which is used (Ranged Based or Image Based. Sometimes it is very difficult to achieve it because of hidden parts, occlusions, and obstructions which the object has. Hence, more data are necessary in order to 3D digitise the whole of the artefact leading to increased time for collecting and consequently processing the data. A methodology is necessary in order to reduce the collection of the data and therefore their processing time especially in cases of mass digitisation. So in this paper, the use of mirrors in particular high-quality mirrors in the data acquisition phase for the 3D reconstruction of small artefacts is investigated. Two case studies of 3D reconstruction are presented: the first one concerns Range-Based modelling especially a Time of Flight laser scanner is utilised and in the second one Image-Based modelling technique is implemented.

  15. Image recovery by removing stochastic artefacts identified as local asymmetries

    International Nuclear Information System (INIS)

    Osterloh, K; Zscherpel, U; Ewert, U; Bücherl, T

    2012-01-01

    Stochastic artefacts are frequently encountered in digital radiography and tomography with neutrons. Most obviously, they are caused by ubiquitous scattered radiation hitting the CCD-sensor. They appear as scattered dots and, at higher frequency of occurrence, they may obscure the image. Some of these dotted interferences vary with time, however, a large portion of them remains persistent so the problem cannot be resolved by collecting stacks of images and to merge them to a median image. The situation becomes even worse in computed tomography (CT) where each artefact causes a circular pattern in the reconstructed plane. Therefore, these stochastic artefacts have to be removed completely and automatically while leaving the original image content untouched. A simplified image acquisition and artefact removal tool was developed at BAM and is available to interested users. Furthermore, an algorithm complying with all the requirements mentioned above was developed that reliably removes artefacts that could even exceed the size of a single pixel without affecting other parts of the image. It consists of an iterative two-step algorithm adjusting pixel values within a 3 × 3 matrix inside of a 5 × 5 kernel and the centre pixel only within a 3 × 3 kernel, resp. It has been applied to thousands of images obtained from the NECTAR facility at the FRM II in Garching, Germany, without any need of a visual control. In essence, the procedure consists of identifying and tackling asymmetric intensity distributions locally with recording each treatment of a pixel. Searching for the local asymmetry with subsequent correction rather than replacing individually identified pixels constitutes the basic idea of the algorithm. The efficiency of the proposed algorithm is demonstrated with a severely spoiled example of neutron radiography and tomography as compared with median filtering, the most convenient alternative approach by visual check, histogram and power spectra analysis.

  16. A short overview of MRI artefacts

    African Journals Online (AJOL)

    Enrique

    sampling in the phase-encoding direction is the significant difference in the time of acquisition in the fre- ... Department of Medical Physics. University of the Free State. Bloemfontein. Fig. 1. Motion artefact (T1 ..... to image expansion for improved definition. IEEE Trans Med Imaging 1994; 3:233-242. 13. Holden M, Breeuwer ...

  17. Removing Ocular Movement Artefacts by a Joint Smoothened Subspace Estimator

    Directory of Open Access Journals (Sweden)

    Ronald Phlypo

    2007-01-01

    Full Text Available To cope with the severe masking of background cerebral activity in the electroencephalogram (EEG by ocular movement artefacts, we present a method which combines lower-order, short-term and higher-order, long-term statistics. The joint smoothened subspace estimator (JSSE calculates the joint information in both statistical models, subject to the constraint that the resulting estimated source should be sufficiently smooth in the time domain (i.e., has a large autocorrelation or self predictive power. It is shown that the JSSE is able to estimate a component from simulated data that is superior with respect to methodological artefact suppression to those of FastICA, SOBI, pSVD, or JADE/COM1 algorithms used for blind source separation (BSS. Interference and distortion suppression are of comparable order when compared with the above-mentioned methods. Results on patient data demonstrate that the method is able to suppress blinking and saccade artefacts in a fully automated way.

  18. The Role of Artefacts in Presence Mediation

    NARCIS (Netherlands)

    Vyas, Dhaval; Tzovaras, D

    2007-01-01

    Approaches to support computer mediated communication (CMC) have predominantly relied on the face-to-face communication paradigm. However, interaction and coordination can also be supported by different technological artefacts. In fact, most researches [1, 2, 3] related to ethnomethodology have

  19. Ring down artefacts on abdominal sonography to predict pulmonary abnormalities in the emergency department.

    Science.gov (United States)

    Tsai, C-L; Wang, H-P; Lien, W-C; Chen, C-C; Lai, T-I; Chen, W-J

    2005-10-01

    Ring down artefacts are sometimes found when emergency physicians perform abdominal ultrasound to differentiate between various abdominal problems. We describe a patient who presented with right upper quadrant abdominal pain and whose ultrasound examination showed ring down artefacts posterior to the right hemidiaphragm, which led to the eventual diagnosis of pneumonia. Ring down artefacts on ultrasound may be used to predict pulmonary abnormalities. Awareness of this sonographic finding may assist in accurate diagnosis and administration of appropriate treatment without delay.

  20. Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants

    International Nuclear Information System (INIS)

    Goerres, Gerhard W.; Hany, Thomas F.; Kamel, Ehab; Schulthess von, Gustav K.; Buck, Alfred

    2002-01-01

    Germanium-68 based attenuation correction (PET Ge68 ) is performed in positron emission tomography (PET) imaging for quantitative measurements. With the recent introduction of combined in-line PET/CT scanners, CT data can be used for attenuation correction. Since dental implants can cause artefacts in CT images, CT-based attenuation correction (PET CT ) may induce artefacts in PET images. The purpose of this study was to evaluate the influence of dental metallic artwork on the quality of PET images by comparing non-corrected images and images attenuation corrected by PET Ge68 and PET CT . Imaging was performed on a novel in-line PET/CT system using a 40-mAs scan for PET CT in 41 consecutive patients with high suspicion of malignant or inflammatory disease. In 17 patients, additional PET Ge68 images were acquired in the same imaging session. Visual analysis of fluorine-18 fluorodeoxyglucose (FDG) distribution in several regions of the head and neck was scored on a 4-point scale in comparison with normal grey matter of the brain in the corresponding PET images. In addition, artefacts adjacent to dental metallic artwork were evaluated. A significant difference in image quality scoring was found only for the lips and the tip of the nose, which appeared darker on non-corrected than on corrected PET images. In 33 patients, artefacts were seen on CT, and in 28 of these patients, artefacts were also seen on PET imaging. In eight patients without implants, artefacts were seen neither on CT nor on PET images. Direct comparison of PET Ge68 and PET CT images showed a different appearance of artefacts in 3 of 17 patients. Malignant lesions were equally well visible using both transmission correction methods. Dental implants, non-removable bridgework etc. can cause artefacts in attenuation-corrected images using either a conventional 68 Ge transmission source or the CT scan obtained with a combined PET/CT camera. We recommend that the non-attenuation-corrected PET images also be

  1. Dosimetric impact of a CT metal artefact suppression algorithm for proton, electron and photon therapies

    International Nuclear Information System (INIS)

    Wei Jikun; Sandison, George A; Hsi, W-C; Ringor, Michael; Lu Xiaoyi

    2006-01-01

    Accurate dose calculation is essential to precision radiation treatment planning and this accuracy depends upon anatomic and tissue electron density information. Modern treatment planning inhomogeneity corrections use x-ray CT images and calibrated scales of tissue CT number to electron density to provide this information. The presence of metal in the volume scanned by an x-ray CT scanner causes metal induced image artefacts that influence CT numbers and thereby introduce errors in the radiation dose distribution calculated. This paper investigates the dosimetric improvement achieved by a previously proposed x-ray CT metal artefact suppression technique when the suppressed images of a patient with bilateral hip prostheses are used in commercial treatment planning systems for proton, electron or photon therapies. For all these beam types, this clinical image and treatment planning study reveals that the target may be severely underdosed if a metal artefact-contaminated image is used for dose calculations instead of the artefact suppressed one. Of the three beam types studied, the metal artefact suppression is most important for proton therapy dose calculations, intermediate for electron therapy and least important for x-ray therapy but still significant. The study of a water phantom having a metal rod simulating a hip prosthesis indicates that CT numbers generated after image processing for metal artefact suppression are accurate and thus dose calculations based on the metal artefact suppressed images will be of high fidelity

  2. A framework to evaluate the educational potential of a digital artefact for math learning

    Directory of Open Access Journals (Sweden)

    Chiappini Giampaolo

    2015-12-01

    Full Text Available This article provides a methodology with two potential applications: to prove useful to maths teachers for analysing and evaluating the educational potential of different digital artefacts and to help designers of maths learning artefacts to evaluate their design during the implementation phase. The educational potential of an artefact is considered as an entity determined by actions and representations structure available within the artefact, the interpretation and behaviour of who uses it and the features of the activity in which it is used. The proposed methodology is based on the notions of affordance, narrative and cycle of expansive learning. The methodology has been applied on AlNuSet, a system designed for supporting the teaching and learning of algebra by means of modalities of interaction that are of visual, spatial and motor nature.

  3. ASPECTS OF BIODETERIORATION OF LAPIDEOUS SUBMERGED ARTEFACTS: 3D METHODOLOGIES APPLICATION

    Directory of Open Access Journals (Sweden)

    S. Ricci

    2015-04-01

    Full Text Available Submerged stone archaeological artefacts are bioeroded by endolithic microbiota (cyanobacteria, algae and fungi and macroborers (Porifera, Bivalvia and Sipuncula. Optical microscope and SEM observations permit to analyse the bioerosion traces and to identify bioeroders. Data obtained with these techniques cannot be used to estimate volumes of material bioeroded. This aspect require the need to collect three-dimensional, close-range data from artefact. In this work we illustrate two 3D imaging techniques used to study bioerosion phenomena of underwater Cultural Heritage. In particular Digital Video Microscope permit the elaboration of 3D images, which are widely employed for close-range acquisitions. Underwater Laser Scanner documents the in situ degradation of submerged artefacts. This research aims to sensitize specialist figures in the study 3D offering a starting point for future collaborations that could lead to interesting results.

  4. Robust motion artefact resistant circuit for calculation of Mean Arterial Pressure from pulse transit time.

    Science.gov (United States)

    Bhattacharya, Tinish; Gupta, Ankesh; Singh, Salam ThoiThoi; Roy, Sitikantha; Prasad, Anamika

    2017-07-01

    Cuff-less and non-invasive methods of Blood Pressure (BP) monitoring have faced a lot of challenges like stability, noise, motion artefact and requirement for calibration. These factors are the major reasons why such devices do not get approval from the medical community easily. One such method is calculating Blood Pressure indirectly from pulse transit time (PTT) obtained from electrocardiogram (ECG) and Photoplethysmogram (PPG). In this paper we have proposed two novel analog signal conditioning circuits for ECG and PPG that increase stability, remove motion artefacts, remove the sinusoidal wavering of the ECG baseline due to respiration and provide consistent digital pulses corresponding to blood pulses/heart-beat. We have combined these two systems to obtain the PTT and then correlated it with the Mean Arterial Pressure (MAP). The aim was to perform major part of the processing in analog domain to decrease processing load over microcontroller so as to reduce cost and make it simple and robust. We have found from our experiments that the proposed circuits can calculate the Heart Rate (HR) with a maximum error of ~3.0% and MAP with a maximum error of ~2.4% at rest and ~4.6% in motion.

  5. Diffusion-weighted imaging of the liver at 3 T using section-selection gradient reversal: emphasis on chemical shift artefacts and lesion conspicuity

    International Nuclear Information System (INIS)

    Lee, J.S.; Kim, Y.K.; Jeong, W.K.; Choi, D.; Lee, W.J.

    2015-01-01

    Aim: To assess the value of section-selection gradient reversal (SSGR) in liver diffusion-weighted imaging (DWI) by comparing it to conventional DWI with an emphasis on chemical shift artefacts and lesion conspicuity. Materials and methods: Forty-eight patients (29 men and 19 women; age range 33–80 years) with 48 liver lesions underwent two DWI examinations using spectral presaturation with inversion recovery fat suppression with and without SSGR at 3 T. Two reviewers evaluated each DWI (b = 100 and b = 800 image) with respect to chemical shift artefacts and liver lesion conspicuity using five-point scales and performed pairwise comparisons between the two DWIs. The signal-to-noise ratio (SNR) of the liver and the lesion and the lesion–liver contrast-to-noise ratio (CNR) were also calculated. Results: SSGR-DWI was significantly better than conventional DWI with respect to chemical shift artefacts and lesion conspicuity in both separate reviews and pairwise comparisons (p < 0.05). There were significant differences in the SNR of the liver (b = 100 and b = 800 images) and lesion (b = 800) between SSGR-DWI and conventional DWI (p < 0.05). Conclusion: Applying the SSGR method to DWI using SPIR fat suppression at 3 T could significantly reduce chemical shift artefacts without incurring additional acquisition time or SNR penalties, which leads to increased conspicuity of focal liver lesions. - Highlights: • Chemical shift artefact in liver DWI is markedly decreased by applying SSGR. • Liver lesion conspicuity is improved by applying SSGR to DWI. • In SNR of the liver, SSGR-DWI is better than conventional DWI

  6. Mine detection using SF-GPR: A signal processing approach for resolution enhancement and clutter reduction

    DEFF Research Database (Denmark)

    Karlsen, Brian; Jakobsen, Kaj Bjarne; Larsen, Jan

    2001-01-01

    Proper clutter reduction is essential for Ground Penetrating Radar data since low signal-to-clutter ratio prevent correct detection of mine objects. A signal processing approach for resolution enhancement and clutter reduction used on Stepped-Frequency Ground Penetrating Radar (SF-GPR) data is pr....... The clutter reduction method is based on basis function decomposition of the SF-GPR time-series from which the clutter and the signal are separated....

  7. Subspace-Based Noise Reduction for Speech Signals via Diagonal and Triangular Matrix Decompositions

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Søren Holdt

    2007-01-01

    We survey the definitions and use of rank-revealing matrix decompositions in single-channel noise reduction algorithms for speech signals. Our algorithms are based on the rank-reduction paradigm and, in particular, signal subspace techniques. The focus is on practical working algorithms, using both...... with working Matlab code and applications in speech processing....

  8. METHODOLOGY TO CREATE DIGITAL AND VIRTUAL 3D ARTEFACTS IN ARCHAEOLOGY

    Directory of Open Access Journals (Sweden)

    Calin Neamtu

    2016-12-01

    Full Text Available The paper presents a methodology to create 3D digital and virtual artefacts in the field of archaeology using CAD software solution. The methodology includes the following steps: the digitalization process, the digital restoration and the dissemination process within a virtual environment. The resulted 3D digital artefacts have to be created in files formats that are compatible with a large variety of operating systems and hardware configurations such as: computers, graphic tablets and smartphones. The compatibility and portability of these 3D file formats has led to a series of quality related compromises to the 3D models in order to integrate them on in a wide variety of application that are running on different hardware configurations. The paper illustrates multiple virtual reality and augmented reality application that make use of the virtual 3D artefacts that have been generated using this methodology.

  9. Minimizing EIT image artefacts from mesh variability in finite element models.

    Science.gov (United States)

    Adler, Andy; Lionheart, William R B

    2011-07-01

    Electrical impedance tomography (EIT) solves an inverse problem to estimate the conductivity distribution within a body from electrical simulation and measurements at the body surface, where the inverse problem is based on a solution of Laplace's equation in the body. Most commonly, a finite element model (FEM) is used, largely because of its ability to describe irregular body shapes. In this paper, we show that simulated variations in the positions of internal nodes within a FEM can result in serious image artefacts in the reconstructed images. Such variations occur when designing FEM meshes to conform to conductivity targets, but the effects may also be seen in other applications of absolute and difference EIT. We explore the hypothesis that these artefacts result from changes in the projection of the anisotropic conductivity tensor onto the FEM system matrix, which introduces anisotropic components into the simulated voltages, which cannot be reconstructed onto an isotropic image, and appear as artefacts. The magnitude of the anisotropic effect is analysed for a small regular FEM, and shown to be proportional to the relative node movement as a fraction of element size. In order to address this problem, we show that it is possible to incorporate a FEM node movement component into the formulation of the inverse problem. These results suggest that it is important to consider artefacts due to FEM mesh geometry in EIT image reconstruction.

  10. A Philosophical Framework for Enhancing the Understanding of Artefacts in the Technology Classroom

    Science.gov (United States)

    Rauscher, Willem

    2016-01-01

    Technology teachers should have a sound understanding and knowledge of artefacts in order to assist learners in the designing, making and evaluating of artefacts. Unfortunately, technology teachers in South African schools seem to have a poor grasp of the complexity of this important part of knowledge that is specific to technology. As a result,…

  11. Matter(s) of interest: artefacts, spacing and timing

    NARCIS (Netherlands)

    Schwanen, T.

    2007-01-01

    This paper argues that time-geography can make a contribution to contemporary 'rematerialized' geographies, because the interconnections among social processes, human corporeality and inanimate material artefacts within the landscape were among Hägerstrand's central concerns. Time-geography needs

  12. Designing the e-Participation Artefact

    DEFF Research Database (Denmark)

    Sanford, Clive Carlton; Rose, Jeremy

    2008-01-01

    When e-participation is considered in the context of applied research, researchers support government institutions by enabling technology for citizens who participate in policy-making. Governments' e-participation agendas involve a variety of different design activities; for example, designing new...... administrative procedures, computer literacy programs, or creating new laws. Design science aids the creation and evaluation of artefacts that are intended to find solutions to identified problems in a rigorous way. We therefore characterise three different types of e-participation design activities...

  13. Computer Simulation of Multidimensional Archaeological Artefacts

    Directory of Open Access Journals (Sweden)

    Vera Moitinho de Almeida

    2012-11-01

    Our project focuses on the Neolithic lakeside site of La Draga (Banyoles, Catalonia. In this presentation we will begin by providing a clear overview of the major guidelines used to capture and process 3D digital data of several wooden artefacts. Then, we shall present the use of semi-automated relevant feature extractions. Finally, we intend to share preliminary computer simulation issues.

  14. Problem Solving of Low Data Throughput on Mobile Devices by Artefacts Prebuffering

    Directory of Open Access Journals (Sweden)

    Krejcar Ondrej

    2009-01-01

    Full Text Available The paper deals with a problem of low data throughput on wirelessly connected mobile devices and a possibility to solve this problem by prebuffering of selected artefacts. The basics are in determining the problem parts of a mobile device and solve the problem by a model of data prebuffering-based system enhancement for locating and tracking users inside the buildings. The framework uses a WiFi network infrastructure to allow the mobile device determine its indoor position. User location is used for data prebuffering and for pushing information from a server to PDAs. All server data are saved as artefacts with its indoor position information. Accessing prebuffered data on a mobile device can significantly improve a response time needed to view large multimedia data. The solution was tested on a facility management information system built on purpose with a testing collection of about hundred large size artefacts.

  15. MRI with intraoral orthodontic appliance-a comparative in vitro and in vivo study of image artefacts at 1.5 T.

    Science.gov (United States)

    Zachriat, C; Asbach, P; Blankenstein, K I; Peroz, I; Blankenstein, F H

    2015-01-01

    We investigated artefacts caused from orthodontic appliances at 1.5-T MRI of the head and neck region and whether the image quality can be improved utilizing the artefact-minimizing sequence WARP. In vitro tests were performed by phantom measurements of different orthodontic devices applying different types of MR sequences [echoplanar imaging (EPI), turbo spin echo (TSE) and TSE-WARP, gradient echo (GRE)]. Two independent readers determined after calibration the level of artefacts. Subsequently, the interobserver agreement was calculated. The measurement of artefacts was based on the American Society for Testing Materials Standard F 2119-07. For in vivo imaging, one test person was scanned with an inserted multibracket appliance. The level of artefacts for 27 target regions was evaluated. In vitro: ceramic brackets and ferromagnetic steel brackets produced artefact radii up to 1.12 and 7.40 cm, respectively. WARP reduced these artefacts by an average of 32.7%. The Bland-Altman-Plot indicated that maximum measurement differences of 3 mm have to be expected with two calibrated observers. In vivo: the EPI sequence for brain imaging was not analysable. The TSE sequence of the brain did not demonstrate artefacts except for the nasal cavity. Conversely, the TSE sequence of the cervical spine revealed severe artefacts in the midface region. The GRE sequence appeared to be more susceptible to artefacts than did the TSE sequence. In vitro measurements allow an estimation of the in vivo artefact size. Orthodontic appliances may often remain intraorally when performing MRI. WARP showed a more significant effect in vitro than in vivo.

  16. Understanding sudden environmental and societal change through coupled geochronological and artefact shape analyses

    DEFF Research Database (Denmark)

    Hoggard, Christian Steven; Sauer, Florian Rudolf; Zernack, Anke Verena

    Over the last twenty years, advances in geometric morphometric methodologies have revolutionised how archaeologists understand changes in artefact shape and form (size plus shape) throughout the Quaternary period. Such methodologies provide a high resolution of artefact coverage, and allow...... a critical analysis of previous taxonomic classificatory schemas and human tool-use in the past. Despite this, methodologies into artefact shape through geometric morphometrics have not been integrated within extensive geochronological data to better understand periods of high environmental stress and......, with respect to archaeology, how past societies reacted to such stress. The Laacher See volcanic eruption (c. 13,000 BP) in western Germany is believed, given its hypothesised characteristics, to have had profound impact on the lifeways of hunter-gatherers towards the end of the Final Palaeolithic (Riede, 2017...

  17. Non-invasive NMR stratigraphy of a multi-layered artefact: an ancient detached mural painting.

    Science.gov (United States)

    Di Tullio, Valeria; Capitani, Donatella; Presciutti, Federica; Gentile, Gennaro; Brunetti, Brunetto Giovanni; Proietti, Noemi

    2013-10-01

    NMR stratigraphy was used to investigate in situ, non-destructively and non-invasively, the stratigraphy of hydrogen-rich layers of an ancient Nubian detached mural painting. Because of the detachment procedure, a complex multi-layered artefact was obtained, where, besides layers of the original mural painting, also the materials used during the procedure all became constitutive parts of the artefact. NMR measurements in situ enabled monitoring of the state of conservation of the artefact and planning of minimum representative sampling to validate results obtained in situ by solid-state NMR analysis of the samples. This analysis enabled chemical characterization of all organic materials. Use of reference compounds and prepared specimens assisted data interpretation.

  18. Stratigraphy, artefact industries and hominid associations for Sterkfontein, member 5.

    Science.gov (United States)

    Kuman, K; Clarke, R J

    2000-06-01

    A revised stratigraphy for the early hominid site of Sterkfontein (Gauteng Province, South Africa) reveals a complex distribution of infills in the main excavation area between 2.8 and 1.4 m.y.a, as well as deposits dating to the mid to late Pleistocene. New research now shows that the Member 4 australopithecine breccia (2.8-2.6 Ma) extends further west than was previously thought, while a late phase of Member 4 is recognized in a southern area. The artefact-bearing breccias were defined sedimentologically as Member 5, but one supposed part of these younger breccias, the StW 53 infill, lacks in situ stone tools, although it does appear to post-date 2.6 Ma when artefacts first appear in the archaeological record. The StW 53 hominid, previously referred to Homo habilis, is here argued to be Australopithecus. The first artefact-bearing breccia of Member 5 is the Oldowan Infill, estimated at 2-1.7 Ma. It occupies a restricted distribution in Member 5 east and contains an expedient, flake-based tool industry associated with a few fossils of Paranthropos robustus. An enlarged cave opening subsequently admitted one or more Early Acheulean infills associated in Member 5 west with Homo ergaster. The artefacts attest to a larger site accumulation between ca. 1.7 and 1.4 Ma, with more intensive use of quartzite over quartz and a subtle but important shift to large flakes and heavier-duty tools. The available information on palaeoenvironments is summarized, showing an overall change from tropical to sub-tropical gallery forest, forest fringe and woodland conditions in Member 4 to more open woodland and grassland habitats in the later units, but with suggestions of a wet localized topography in the Paranthropus -bearing Oldowan Infill. Copyright 2000 Academic Press.

  19. 3D Visualization of Cultural Heritage Artefacts with Virtual Reality devices

    Science.gov (United States)

    Gonizzi Barsanti, S.; Caruso, G.; Micoli, L. L.; Covarrubias Rodriguez, M.; Guidi, G.

    2015-08-01

    Although 3D models are useful to preserve the information about historical artefacts, the potential of these digital contents are not fully accomplished until they are not used to interactively communicate their significance to non-specialists. Starting from this consideration, a new way to provide museum visitors with more information was investigated. The research is aimed at valorising and making more accessible the Egyptian funeral objects exhibited in the Sforza Castle in Milan. The results of the research will be used for the renewal of the current exhibition, at the Archaeological Museum in Milan, by making it more attractive. A 3D virtual interactive scenario regarding the "path of the dead", an important ritual in ancient Egypt, was realized to augment the experience and the comprehension of the public through interactivity. Four important artefacts were considered for this scope: two ushabty, a wooden sarcophagus and a heart scarab. The scenario was realized by integrating low-cost Virtual Reality technologies, as the Oculus Rift DK2 and the Leap Motion controller, and implementing a specific software by using Unity. The 3D models were implemented by adding responsive points of interest in relation to important symbols or features of the artefact. This allows highlighting single parts of the artefact in order to better identify the hieroglyphs and provide their translation. The paper describes the process for optimizing the 3D models, the implementation of the interactive scenario and the results of some test that have been carried out in the lab.

  20. 3D Visualization of Cultural Heritage Artefacts with Virtual Reality devices

    Directory of Open Access Journals (Sweden)

    S. Gonizzi Barsanti

    2015-08-01

    Full Text Available Although 3D models are useful to preserve the information about historical artefacts, the potential of these digital contents are not fully accomplished until they are not used to interactively communicate their significance to non-specialists. Starting from this consideration, a new way to provide museum visitors with more information was investigated. The research is aimed at valorising and making more accessible the Egyptian funeral objects exhibited in the Sforza Castle in Milan. The results of the research will be used for the renewal of the current exhibition, at the Archaeological Museum in Milan, by making it more attractive. A 3D virtual interactive scenario regarding the “path of the dead”, an important ritual in ancient Egypt, was realized to augment the experience and the comprehension of the public through interactivity. Four important artefacts were considered for this scope: two ushabty, a wooden sarcophagus and a heart scarab. The scenario was realized by integrating low-cost Virtual Reality technologies, as the Oculus Rift DK2 and the Leap Motion controller, and implementing a specific software by using Unity. The 3D models were implemented by adding responsive points of interest in relation to important symbols or features of the artefact. This allows highlighting single parts of the artefact in order to better identify the hieroglyphs and provide their translation. The paper describes the process for optimizing the 3D models, the implementation of the interactive scenario and the results of some test that have been carried out in the lab.

  1. Xylem resistance to embolism: presenting a simple diagnostic test for the open vessel artefact.

    Science.gov (United States)

    Torres-Ruiz, José M; Cochard, Hervé; Choat, Brendan; Jansen, Steven; López, Rosana; Tomášková, Ivana; Padilla-Díaz, Carmen M; Badel, Eric; Burlett, Regis; King, Andrew; Lenoir, Nicolas; Martin-StPaul, Nicolas K; Delzon, Sylvain

    2017-07-01

    Xylem vulnerability to embolism represents an essential trait for the evaluation of the impact of hydraulics in plant function and ecology. The standard centrifuge technique is widely used for the construction of vulnerability curves, although its accuracy when applied to species with long vessels remains under debate. We developed a simple diagnostic test to determine whether the open-vessel artefact influences centrifuge estimates of embolism resistance. Xylem samples from three species with differing vessel lengths were exposed to less negative xylem pressures via centrifugation than the minimum pressure the sample had previously experienced. Additional calibration was obtained from non-invasive measurement of embolism on intact olive plants by X-ray microtomography. Results showed artefactual decreases in hydraulic conductance (k) for samples with open vessels when exposed to a less negative xylem pressure than the minimum pressure they had previously experienced. X-Ray microtomography indicated that most of the embolism formation in olive occurs at xylem pressures below -4.0 MPa, reaching 50% loss of hydraulic conductivity at -5.3 MPa. The artefactual reductions in k induced by centrifugation underestimate embolism resistance data of species with long vessels. A simple test is suggested to avoid this open vessel artefact and to ensure the reliability of this technique in future studies. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.

  2. Morphological image processing operators. Reduction of partial volume effects to improve 3D visualization based on CT data

    International Nuclear Information System (INIS)

    Beier, J.; Bittner, R.C.; Hosten, N.; Troeger, J.; Felix, R.

    1998-01-01

    Aim: The quality of segmentation and three-dimensional reconstruction of anatomical structures in tomographic slices is often impaired by disturbances due to partial volume effects (PVE). The potential for artefact reduction by use of the morphological image processing operators (MO) erosion and dilation is investigated. Results: For all patients under review, the artefacts caused by PVE were significantly reduced by erosion (lung: Mean SBR pre =1.67, SBR post =4.83; brain: SBR pre =1.06, SBR post =1.29) even with only a small number of iterations. Region dilation was applied to integrate further structures (e.g. at tumor borders) into a configurable neighbourhood for segmentation and quantitative analysis. Conclusions: The MO represent an efficient approach for the reduction of PVE artefacts in 3D-CT reconstructions and allow optimised visualization of individual objects. (orig./AJ) [de

  3. MRI with intraoral orthodontic appliance—a comparative in vitro and in vivo study of image artefacts at 1.5 T

    Science.gov (United States)

    Zachriat, C; Asbach, P; Blankenstein, K I; Peroz, I

    2015-01-01

    Objectives: We investigated artefacts caused from orthodontic appliances at 1.5-T MRI of the head and neck region and whether the image quality can be improved utilizing the artefact-minimizing sequence WARP. Methods: In vitro tests were performed by phantom measurements of different orthodontic devices applying different types of MR sequences [echoplanar imaging (EPI), turbo spin echo (TSE) and TSE-WARP, gradient echo (GRE)]. Two independent readers determined after calibration the level of artefacts. Subsequently, the interobserver agreement was calculated. The measurement of artefacts was based on the American Society for Testing Materials Standard F 2119-07. For in vivo imaging, one test person was scanned with an inserted multibracket appliance. The level of artefacts for 27 target regions was evaluated. Results: In vitro: ceramic brackets and ferromagnetic steel brackets produced artefact radii up to 1.12 and 7.40 cm, respectively. WARP reduced these artefacts by an average of 32.7%. The Bland–Altman-Plot indicated that maximum measurement differences of 3 mm have to be expected with two calibrated observers. In vivo: the EPI sequence for brain imaging was not analysable. The TSE sequence of the brain did not demonstrate artefacts except for the nasal cavity. Conversely, the TSE sequence of the cervical spine revealed severe artefacts in the midface region. The GRE sequence appeared to be more susceptible to artefacts than did the TSE sequence. Conclusions: In vitro measurements allow an estimation of the in vivo artefact size. Orthodontic appliances may often remain intraorally when performing MRI. WARP showed a more significant effect in vitro than in vivo. PMID:25734243

  4. Usefulness of IDEAL T2 imaging for homogeneous fat suppression and reducing susceptibility artefacts in brachial plexus MRI at 3.0 T.

    Science.gov (United States)

    Tagliafico, Alberto; Bignotti, Bianca; Tagliafico, Giulio; Martinoli, Carlo

    2016-01-01

    To quantitatively and qualitatively compare fat-suppressed MR imaging quality using iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) with that using frequency-selective fat-suppressed (FSFS) T2 images of the brachial plexus at 3.0 T. Prospective MR image analysis was performed in 40 volunteers and 40 patients at a single centre. Oblique-sagittal and coronal IDEAL fat-suppressed T2 images and FSFS T2 images were compared. Visual assessment was performed by two independent musculoskeletal radiologists with respect to: (1) susceptibility artefacts around the neck, (2) homogeneity of fat suppression, (3) image sharpness and (4) tissue resolution contrast of pathologies. The signal-to-noise ratios (SNR) for each image sequence were assessed. Compared to FSFS sequences, IDEAL fat-suppressed T2 images significantly reduced artefacts around the brachial plexus and significantly improved homogeneous fat suppression (p < 0.05). IDEAL significantly improved sharpness and lesion-to-tissue contrast (p < 0.05). The mean SNRs were significantly improved on T2-weighted IDEAL images (p < 0.05). IDEAL technique improved image quality by reducing artefacts around the brachial plexus while maintaining a high SNR and provided superior homogeneous fat suppression than FSFS sequences.

  5. Quantitative analysis of orthopedic metal artefact reduction in 64-slice computed tomography scans in large head metal-on-metal total hip replacement, a phantom study

    NARCIS (Netherlands)

    Boomsma, Martijn F.; Warringa, Niek; Edens, Mireille A.; Mueller, Dirk; Ettema, Harmen B.; Verheyen, Cees C. P. M.; Maas, Mario

    2016-01-01

    Purpose: Quantification of the effect of O-MAR on decreasing metal artefacts caused by large head metal on metal total hip arthroplasty (MoM THA) in a dedicated phantom setup of the hip. Background: Pathological reactions of the hip capsule on Computed tomography (CT) can be difficult to diagnose

  6. Electrocardiogram (ECG Signal Modeling and Noise Reduction Using Hopfield Neural Networks

    Directory of Open Access Journals (Sweden)

    F. Bagheri

    2013-02-01

    Full Text Available The Electrocardiogram (ECG signal is one of the diagnosing approaches to detect heart disease. In this study the Hopfield Neural Network (HNN is applied and proposed for ECG signal modeling and noise reduction. The Hopfield Neural Network (HNN is a recurrent neural network that stores the information in a dynamic stable pattern. This algorithm retrieves a pattern stored in memory in response to the presentation of an incomplete or noisy version of that pattern. Computer simulation results show that this method can successfully model the ECG signal and remove high-frequency noise.

  7. Beyond tokenistic participation: using representational artefacts to enable meaningful public participation in health service design.

    Science.gov (United States)

    Morrison, Cecily; Dearden, Andy

    2013-10-01

    A number of recent policies promote public participation in health service design. Yet, a growing literature has articulated a gap between policy aims and actual practice resulting in public participation becoming tokenistic. Drawing on theory from participatory design, we argue that choosing appropriate artefacts to act as representations can structure discussions between public participants and health professionals in ways that both groups find meaningful and valid. Through a case study of a service improvement project in outpatient services for older people, we describe three representational artefacts: emotion maps, stories, and tracing paper, and explain how they helped to mediate interactions between public participants and health professionals. We suggest that using such representational artefacts can provide an alternative approach to participation that stands in contrast to the current focus on the professionalisation of public participants. We conclude that including participatory designers in projects, to chose or design appropriate representational artefacts, can help to address the policy-practice gap of including public participants in health service design. Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.

  8. An Evaluation View of an Ensemble Artefact for Decision Support using Action Design Research

    Directory of Open Access Journals (Sweden)

    Dale MacKrell

    2016-11-01

    Full Text Available This paper investigates the integration of content, context and process (CCP into the Action Design Research (ADR framework to account for the interplay of organisational issues in artefact design and development. The investigation is conducted through a case study in which successive ICT student teams incrementally build, over several semesters, a tailored, low cost business intelligence (BI system as an ensemble artefact for an organisation in the not-for-profit (NFP sector. During project development, CCP’s human-centred approach to evaluation complements ADR’s more prescribed technology-driven software testing. The integration of CCP into ADR as an evaluation view offers an holistic approach to assessing an ensemble artefact. The resultant conceptual framework is presented as a model with an explication of unexpected design and research outcomes.

  9. Analysis artefacts of the INS-IGF2 fusion transcript

    DEFF Research Database (Denmark)

    Wernersson, Rasmus; Frogne, Thomas; Rescan, Claude

    2015-01-01

    Background: In gene expression analysis, overlapping genes, splice variants, and fusion transcripts are potential sources of data analysis artefacts, depending on how the observed intensity is assigned to one, or more genes. We here exemplify this by an in-depth analysis of the INS-IGF2 fusion...... transcript, which has recently been reported to be among the highest expressed transcripts in human pancreatic beta cells and its protein indicated as a novel autoantigen in Type 1 Diabetes. Results: Through RNA sequencing and variant specific qPCR analyses we demonstrate that the true abundance of INS-IGF2...... is >20,000 fold lower than INS in human beta cells, and we suggest an explanation to the nature of the artefacts which have previously led to overestimation of the gene expression level in selected studies. We reinvestigated the previous reported findings of detection of INS-IGF2 using antibodies both...

  10. Novel Signal Noise Reduction Method through Cluster Analysis, Applied to Photoplethysmography.

    Science.gov (United States)

    Waugh, William; Allen, John; Wightman, James; Sims, Andrew J; Beale, Thomas A W

    2018-01-01

    Physiological signals can often become contaminated by noise from a variety of origins. In this paper, an algorithm is described for the reduction of sporadic noise from a continuous periodic signal. The design can be used where a sample of a periodic signal is required, for example, when an average pulse is needed for pulse wave analysis and characterization. The algorithm is based on cluster analysis for selecting similar repetitions or pulses from a periodic single. This method selects individual pulses without noise, returns a clean pulse signal, and terminates when a sufficiently clean and representative signal is received. The algorithm is designed to be sufficiently compact to be implemented on a microcontroller embedded within a medical device. It has been validated through the removal of noise from an exemplar photoplethysmography (PPG) signal, showing increasing benefit as the noise contamination of the signal increases. The algorithm design is generalised to be applicable for a wide range of physiological (physical) signals.

  11. Subspace-Based Noise Reduction for Speech Signals via Diagonal and Triangular Matrix Decompositions

    DEFF Research Database (Denmark)

    Hansen, Per Christian; Jensen, Søren Holdt

    We survey the definitions and use of rank-revealing matrix decompositions in single-channel noise reduction algorithms for speech signals. Our algorithms are based on the rank-reduction paradigm and, in particular, signal subspace techniques. The focus is on practical working algorithms, using both...... diagonal (eigenvalue and singular value) decompositions and rank-revealing triangular decompositions (ULV, URV, VSV, ULLV and ULLIV). In addition we show how the subspace-based algorithms can be evaluated and compared by means of simple FIR filter interpretations. The algorithms are illustrated...... with working Matlab code and applications in speech processing....

  12. What Then Happens When Interaction is Not Possible: The Virtuosic Interpretation of Ergodic Artefacts

    Directory of Open Access Journals (Sweden)

    Miguel Carvalhais

    2015-11-01

    Full Text Available Procedural systems allow unique modes of authorship and singular aesthetic experiences. As creators and users of these systems, we need to be aware that their aesthetic potential is not solely defined by interaction but that interpretation, and the capacity to understand and simulate the processes taking place within these artefacts is highly significant. This paper argues that although direct interaction is usually the most discernible component in the relationship between ergodic artefacts and their users, ergodicity does not necessarily imply interaction. Non-interactive procedural artefacts may allow the development of ergodic experiences through interpretation, and the probing of the system by its reader through simulations. We try to set the grounds for designing towards virtuosic interpretation, an activity that we may describe as the ergodic experience developed by means of mental simulation through the development of theories of systems.

  13. Transforming Artefacts into Digital Heritage

    DEFF Research Database (Denmark)

    Otto, Ton; Hardy, Dianna

    2016-01-01

    a genuine transformation of the artefacts that opens up new possibilities of use. These include providing access to and facilitating the reappropriation of cultural knowledge stored elsewhere, maintaining and developing a living digital cultural heritage, and gathering, sharing and transferring knowledge...... that is available within Aboriginal communities. In this paper we examine different types of digital repositories and we assess their suitability for use by Aboriginal communities. We classify a number of institutional archiving systems and analyse in some detail two interactive systems that were specifically...... designed for use by Aboriginal communities. The paper ends with a set of recommendations for designing digital databases for Indigenous usage....

  14. Triangular dislocation: an analytical, artefact-free solution

    Science.gov (United States)

    Nikkhoo, Mehdi; Walter, Thomas R.

    2015-05-01

    Displacements and stress-field changes associated with earthquakes, volcanoes, landslides and human activity are often simulated using numerical models in an attempt to understand the underlying processes and their governing physics. The application of elastic dislocation theory to these problems, however, may be biased because of numerical instabilities in the calculations. Here, we present a new method that is free of artefact singularities and numerical instabilities in analytical solutions for triangular dislocations (TDs) in both full-space and half-space. We apply the method to both the displacement and the stress fields. The entire 3-D Euclidean space {R}3 is divided into two complementary subspaces, in the sense that in each one, a particular analytical formulation fulfils the requirements for the ideal, artefact-free solution for a TD. The primary advantage of the presented method is that the development of our solutions involves neither numerical approximations nor series expansion methods. As a result, the final outputs are independent of the scale of the input parameters, including the size and position of the dislocation as well as its corresponding slip vector components. Our solutions are therefore well suited for application at various scales in geoscience, physics and engineering. We validate the solutions through comparison to other well-known analytical methods and provide the MATLAB codes.

  15. Comparison of CT and MRI artefacts from coils and vascular plugs used for portal vein embolization

    Energy Technology Data Exchange (ETDEWEB)

    Geisel, Dominik, E-mail: dominik.geisel@charite.de [Department of Diagnostic and Interventional Radiology, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Gebauer, Bernhard [Department of Diagnostic and Interventional Radiology, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Malinowski, Maciej; Stockmann, Martin [Department of General, Visceral and Transplantation Surgery, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany); Denecke, Timm [Department of Diagnostic and Interventional Radiology, Charité, Campus Virchow-Klinikum, Augustenburger Platz 1, 13353 Berlin (Germany)

    2014-04-15

    Purpose: To retrospectively analyze the degree of artefacts in CT and MRI scans caused by coils and vascular plugs used for portal vein embolization (PVE). Materials and methods: All patients who underwent PVE between July 2011 and December 2012 and received either plug or coil embolization additional to particle embolization were retrospectively analyzed. Artefacts causes by embolization materials were measured in CT and MRI scans following PVE. Results: The sum of the artefact diameters caused from coils was significantly higher in CT (188.3 ± 26.1 mm) than in MRI T1 (50.5 ± 6.5 mm) or T2 imaging (39.5 ± 9.7 mm) (P < 0.05). In MRI, the diameter in T1 and T2 sequences did not differ significantly (P = 0.977). The sum of the artefact diameters from vascular plugs in MRI T1 sequences (62.5 ± 8.7 mm) was significantly higher than in CT (46.6 ± 4.8 mm; P < 0.05) and MRI T2 sequences (52.8 ± 3.8 mm; P < 0.05). Conclusion: PVE with particles and vascular plug causes significantly fewer artefacts than PVE with particles and coils on CT scans following embolization, which can be important in the event of vascular complications or in follow-up scans, should the patient become unresectable.

  16. An investigation of inconsistent projections and artefacts in multi-pinhole SPECT with axially aligned pinholes

    International Nuclear Information System (INIS)

    Kench, P L; Meikle, S R; Lin, J; Gregoire, M C

    2011-01-01

    Multiple pinholes are advantageous for maximizing the use of the available field of view (FOV) of compact small animal single photon emission computed tomography (SPECT) detectors. However, when the pinholes are aligned axially to optimize imaging of extended objects, such as rodents, multiplexing of the pinhole projections can give rise to inconsistent data which leads to 'ghost point' artefacts in the reconstructed volume. A novel four pinhole collimator with a baffle was designed and implemented to eliminate these inconsistent projections. Simulation and physical phantom studies were performed to investigate artefacts from axially aligned pinholes and the efficacy of the baffle in removing inconsistent data and, thus, reducing reconstruction artefacts. SPECT was performed using a Defrise phantom to investigate the impact of collimator design on FOV utilization and axial blurring effects. Multiple pinhole SPECT acquired with a baffle had fewer artefacts and improved quantitative accuracy when compared to SPECT acquired without a baffle. The use of four pinholes positioned in a square maximized the available FOV, increased acquisition sensitivity and reduced axial blurring effects. These findings support the use of a baffle to eliminate inconsistent projection data arising from axially aligned pinholes and improve small animal SPECT reconstructions.

  17. FT-Raman and FT-Infrared investigations of archaeological artefacts from Foeni Neolithic site (Banat, Romania

    Directory of Open Access Journals (Sweden)

    Simona Cîntă Pînzaru

    2008-08-01

    Full Text Available An impressive collection of chert artefacts from the Foeni Neolithic archaeological site (Timiş County, Banat region, Romania is hosted by the Banat Museum in Timişoara. A representative set of seven specimens was non-destructively investigated using FT-Raman and ATR-FT-IR spectroscopy. The research was carried out for checking if these readily-available, non-destructive, fast, and cheap methods, which do not require preliminary sample preparation could provide significant information for characterizing the mineral composition of chert artefacts. Based on vibrational data, it was confirmed that the raw material was represented by microcrystalline quartz and moganite, with local concentrations of accessory minerals (calcite, dolomite, and clay minerals. In spite of their wide macroscopic heterogeneity (colour, transparency, based on single point FT-Raman measurements the chert artefacts could not be assigned to distinctive groups of raw silica materials, in order to provide specific arguments for provenance studies. However, the presence of specific accessory minerals (dolomite, illite pointed to distinctive genetic conditions in the case of one lithic material. Sets of measurements (mapping are required for statistically characterizing each artefact specimen. IR data were less significant, due to the rough surface texture of the specimens in contact with the ZnSe crystal of the ATR-FT-IR module. However, illite was identified based solely on its contribution to the IR spectrum. This pioneering study on chert artefacts from Romania based on optical spectroscopic methods shows that there are good premises for a systematic investigation of highly-valuable museum collections, in particular in terms of chert geology.

  18. Persistent Artefacts in an Online Classroom: The Value of a Dynamic Learning Archive | Artefacts persistants dans une salle de classe en ligne : la valeur d’une archive dynamique de l’apprentissage

    Directory of Open Access Journals (Sweden)

    Stuart C. Berry

    2016-04-01

    Full Text Available This paper summarizes a multi-year research project that examines the use and value of visible and persistent artefacts within an online learning environment. This study is framed within elements of a business management theory. Changes to an online learning environment are documented as well as an examination of the impact of these changes on the learning process. The study also shows the impact of learner engagement with artefacts over the life of multiple iterations of a course within this socially networked online learning space. Two significant outcomes emerged: 1. How the use of a socially networked online learning environment can offer a rich and supportive place for teaching and learning; and 2. That students in this study support the inclusion of an archive containing artefacts from learners in prior iterations of a course. The connection between the inclusion of this archive and the impact of a socially networked online learning environment will be demonstrated throughout. Cet article résume un projet de recherche sur plusieurs années, examinant l’utilisation et la valeur des artefacts visibles et persistants au sein d’un environnement d’apprentissage en ligne. Cette étude a été structurée selon des éléments d’une théorie de la gestion des affaires. Les modifications à l’environnement d’apprentissage en ligne sont documentées, ainsi que l’examen de l’incidence de ces modifications sur le processus d’apprentissage. L’étude montre aussi l’impact de l’engagement de l’apprenant avec les artefacts sur plusieurs itérations d’un cours dans un espace d’apprentissage en ligne doté de réseaux sociaux. Deux résultats importants ont émergé : 1. un espace d’apprentissage en ligne doté de réseaux sociaux peut offrir un endroit riche et soutenant pour l’enseignement et l’apprentissage; et 2. les étudiants dans cette étude sont favorables à l’inclusion d’une archive rassemblant les

  19. Metabolic cold adaptation of polar fish based on measurements of aerobic oxygen consumption: fact or artefact? Artefact!

    DEFF Research Database (Denmark)

    Steffensen, John Fleng

    2002-01-01

    Whether metabolic cold adaptation in polar fish, based on measurements of aerobic standard metabolic rate, is a fact or an artefact has been a dispute since Holeton asked the question in 1974. So far polar fish had been considered to be metabolically cold adapted because they were reported to have...... a considerably elevated resting oxygen consumption, or standard metabolic rate, compared with oxygen consumption values of tropical or temperate fish extrapolated to similar low polar temperatures. Recent experiments on arctic and Antarctic fish, however, do not show elevated resting aerobic oxygen consumption...

  20. Investigation of archaeological metal artefacts by laser-induced breakdown spectroscopy (LIBS)

    Science.gov (United States)

    Tankova, V.; Malcheva, G.; Blagoev, K.; Leshtakov, L.

    2018-03-01

    In this work, laser-induced breakdown spectroscopy was applied to determining the elemental composition of a set of ancient bronze artefacts dated from the Late Bronze Age and Early Iron Age (14th – 10th century BC). We used a Nd:YAG laser at 1064 nm with pulse duration of 10 ns and energy of 10 mJ and determined the elemental composition of the bronze alloy that was used in manufacturing the samples under study. The concentrations of tin and lead in the bulk of the examined materials was estimated after generating calibration curves for a set of four standard samples. The preliminary results of the analysis will provide information on the artefacts provenance and on the production process.

  1. Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT

    NARCIS (Netherlands)

    Symersky, P.; Habets, J.; Westers, P.; Mol, de B.A.J.M.; Prokop, M.; Budde, R.P.J.

    2012-01-01

    Objectives Multidetector computed tomography (MDCT) has diagnostic value for the evaluation of prosthetic heart valve (PHV) dysfunction but it is hampered by artefacts. We hypothesised that image acquisition using prospective triggering instead of retrospective gating would reduce artefacts related

  2. On the feasibility of establishing the provenance of Australian Aboriginal artefacts using synchrotron radiation X-ray diffraction and proton-induced X-ray emission

    International Nuclear Information System (INIS)

    Creagh, D.C.; Kubik, M.E.; Sterns, M.

    2007-01-01

    Museums and galleries in Australia have extensive collections of Aboriginal artefacts in their custody. In particular, the National Museum of Australia and the National Gallery of Australia are custodians of works of very considerable significance, in both cultural and financial terms. Art fraud can occur, documentation relating to artefacts can be mislaid, or the artefacts can be incorrectly filed. Because of this, it has become essential to establish protocols for the objective determination of the provenance of artefacts through scientific tests. For the work reported here we are concerned with the comparison of very small quantities of materials, paint scrapings from artefacts. Scrapings from artefacts of unknown provenance are compared with those from artefacts of known provenance, and the database established using an extended set of analytical techniques by Kubik. We describe here our use of synchrotron radiation X-ray diffraction (SR-XRD) to determine the mineral phase compositions of very small amounts of pigment material (<50 μg), and the use of PIXE to give their atomic compositions to a threshold level of 1 ppm for similar masses of material

  3. Influence of the in-plane artefact in chest tomosynthesis on pulmonary nodule size measurements

    International Nuclear Information System (INIS)

    Soederman, Christina; Allansdotter Johnsson, Aase; Vikgren, Jenny; Rossi Norrlund, Rauni; Molnar, David; Svalkvist, Angelica; Maansson, Lars Gunnar; Baath, Magnus

    2016-01-01

    The aim of the present study was to investigate how the in-plane artefact present in the scan direction around structures in tomosynthesis images should be managed when measuring the size of nodules in chest tomosynthesis images in order to achieve acceptable measurement accuracy. Data from measurements, performed by radiologists, of the longest diameter of artificial nodules inserted in chest tomosynthesis images were used. The association between the measurement error and the direction of the longest nodule diameter, relative to the scan direction, was evaluated using the Kendall rank correlation coefficient. All of the radiologists had chosen to not include the artefact in the measurements. Significant association between measurement error and the direction of the longest diameter was found for nodules larger than 12 mm, which indicates that, for these nodules, there is a risk of underestimating the nodule size if the in-plane artefact is omitted from manual diameter measurements. (authors)

  4. Corrosion of archaeological iron artefacts compared to modern iron at the waterlogged site Nydam, Denmark

    International Nuclear Information System (INIS)

    Matthiesen, Henning; Gregory, David; Soerensen, Birgit; Hilbert, Rischel Lisbeth

    2004-01-01

    Since 1859 several archaeological excavations have been carried out in Nydam, Denmark revealing a wealth of military equipment sacrificed in the period 200 - 500 AD. During the 1990's more than 16000 artefacts of mainly wood and iron were excavated within an area of only 600 m 2 . Due to the volume of finds it was decided in 1997 to stop further excavations. At the same time a study program was initiated at the National Museum to evaluate the feasibility of preserving the remaining artefacts in situ for a prolonged period. The study comprises all materials present in Nydam, but this presentation focuses solely on the iron objects. A three-pronged approach has been used in the studies in Nydam: 1) Studies of the excavated artefacts, including the composition of corrosion products and a mapping of their exact state of preservation. 2) Use of modern iron samples placed in the soil for studies of weight loss, corrosion potential, electrochemical impedance spectroscopy and electrical resistivity. 3) Measurements of environmental parameters such as water level, redox potential, oxygen concentration, soil pH, and the concentration of a range of dissolved species in the pore water. This presentation shows some of the results obtained during the seven years of studies at the site. It is demonstrated how the three pronged approach is useful in understanding not only the current corrosion rate and threats against the artefacts but also the corrosion history, i.e. when were the deterioration patterns and corrosion products observed today actually formed. The corrosion rates for archaeological artefacts and modern analogues are compared and briefly discussed. (authors)

  5. The role of movies in Norwegian textbooks. A study of film as artefact in religious education

    Directory of Open Access Journals (Sweden)

    Jon Magne Vestøl

    2012-12-01

    Full Text Available Drawing on perspectives on educational design, this article investigates the role of movies in Norwegian secondary school textbooks on religious education, including teachers’ handbooks and textbook websites. All passages containing references to films or movies have been included in the analysis. The distribution of references indicates that a film is an optional artefact and that movies are drawn mainly from a Western cinematic tradition and are related to topics such as Christianity and ethics. When textbook assignments introduce movies as artefacts mediating the understanding of religious issues, information about the message and the artistic role of the film seems to be downplayed. This indicates a need for reflection on how artefacts such as films are introduced into educational activity.

  6. Noise Reduction of Steel Cord Conveyor Belt Defect Electromagnetic Signal by Combined Use of Improved Wavelet and EMD

    Directory of Open Access Journals (Sweden)

    Hong-Wei Ma

    2016-09-01

    Full Text Available In order to reduce the noise of a defect electromagnetic signal of the steel cord conveyor belt used in coal mines, a new signal noise reduction method by combined use of the improved threshold wavelet and Empirical Mode Decomposition (EMD is proposed. Firstly, the denoising method based on the improved threshold wavelet is applied to reduce the noise of a defect electromagnetic signal obtained by an electromagnetic testing system. Then, the EMD is used to decompose the denoised signal and then the effective Intrinsic Mode Function (IMF is extracted by the dominant eigenvalue strategy. Finally, the signal reconstruction is carried out by utilizing the obtained IMF. In order to verify the proposed noise reduction method, the experiments are carried out in two cases including the defective joint and steel wire rope break. The experimental results show that the proposed method in this paper obtains the higher Signal to Noise Ratio (SNR for the defect electromagnetic signal noise reduction of steel cord conveyor belts.

  7. Respiratory motion artefacts in dynamic liver MRI: a comparison using gadoxetate disodium and gadobutrol

    Energy Technology Data Exchange (ETDEWEB)

    Luetkens, Julian A.; Kupczyk, Patrick A.; Doerner, Jonas; Willinek, Winfried A.; Schild, Hans H.; Kukuk, Guido M. [University of Bonn, Department of Radiology, Bonn (Germany); Fimmers, Rolf [University of Bonn, Department of Medical Biometry, Informatics, and Epidemiology, Bonn (Germany)

    2015-11-15

    Our aim was to retrospectively evaluate the occurrence of respiratory motion artefacts in patients undergoing dynamic liver magnetic resonance (MR) either with gadoxetate disodium or gadobutrol. Two hundred and thirty liver MR studies (115 with gadobutrol, 115 with gadoxetate disodium) were analysed. Respiratory motion artefacts on dynamic 3D T1-weighted MR images (pre-contrast, arterial, venous, and late-dynamic phase) were assessed using a five-point rating scale. Severe motion was defined as a score ≥ 4. Mean motion scores were compared with the Mann-Whitney-U-test. The chi-squared-test was used for dichotomous comparisons. Mean motion scores for gadoxetate disodium and gadobutrol showed no relevant differences for each phase of the dynamic contrast series (pre-contrast: 1.85 ± 0.70 vs. 1.88 ± 0.57, arterial: 1.85 ± 0.81 vs. 1.87 ± 0.74, venous: 1.82 ± 0.67 vs. 1.74 ± 0.64, late-dynamic: 1.75 ± 0.62 vs. 1.79 ± 0.63; p = 0.469, 0.557, 0.382 and 0.843, respectively). Severe motion artefacts had a similar incidence using gadoxetate disodium and gadobutrol (11/460 [2.4 %] vs. 7/460 [1.5 %]; p = 0.341). Gadoxetate disodium is associated with equivalent motion scores compared to gadobutrol in dynamic liver MRI. In addition, both contrast agents demonstrated a comparable and acceptable rate of severe respiratory motion artefacts. (orig.)

  8. Ultraviolet signals in birds are special.

    Science.gov (United States)

    Hausmann, Franziska; Arnold, Kathryn E; Marshall, N Justin; Owens, Ian P F

    2003-01-07

    Recent behavioural experiments have shown that birds use ultraviolet (UV)-reflective and fluorescent plumage as cues in mate choice. It remains controversial, however, whether such UV signals play a special role in sexual communication, or whether they are part of general plumage coloration. We use a comparative approach to test for a general association between sexual signalling and either UV-reflective or fluorescent plumage. Among the species surveyed, 72% have UV colours and there is a significant positive association between UV reflectance and courtship displays. Among parrots (Psittaciformes), 68% of surveyed species have fluorescent plumage, and again there is a strong positive association between courtship displays and fluorescence. These associations are not artefacts of the plumage used in courtship displays, being generally more 'colourful' because there is no association between display and colours lacking UV reflectance or fluorescence. Equally, these associations are not phylogenetic artefacts because all results remain unchanged when families or genera, rather than species, are used as independent data points. We also find that, in parrots, fluorescent plumage is usually found adjacent to UV-reflective plumage. Using a simple visual model to examine one parrot, the budgerigar Melopsittacus undulatus, we show that the juxtaposition of UV-reflective and fluorescent plumage leads to a 25-fold increase in chromatic contrast to the budgerigar's visual system. Taken together, these results suggest that signals based on UV contrast are of special importance in the context of active sexual displays. We review briefly six hypotheses on why this may be the case: suitability for short-range signalling; high contrast with backgrounds; invisibility to predators; exploitation of pre-existing sensory biases; advertisement of feather structure; and amplification of behavioural signals.

  9. Reconstruction artefacts in magnetic induction tomography due to patient's movement during data acquisition

    International Nuclear Information System (INIS)

    Gürsoy, D; Scharfetter, H

    2009-01-01

    Magnetic induction tomography (MIT) attempts to obtain the distribution of passive electrical properties inside the body. Eddy currents are induced in the body using an array of transmitter coils and the magnetic fields of these currents are measured by receiver coils. In clinical usage, the relative position of the coils to the body can change during data acquisition because of the expected/unexpected movements of the patient. Especially in respiration monitoring these movements will inevitably cause artefacts in the reconstructed images. In this paper, this effect was investigated for both state and frequency differential variants of MIT. It was found that a slight shift of the body in the transverse plane causes spurious perturbations on the surface. In reconstructions, this artefact on the surface propagates towards the centre in an oscillatory manner. It was observed that the movement can corrupt all the valuable information in state differential MIT, while frequency differential MIT seems more robust against movement effects. A filtering strategy is offered in order to decrease the movement artefacts in the images. To this end, monitoring of the patient's movement during data acquisition is required

  10. PAPR Reduction of OFDM Signals by Novel Global Harmony Search in PTS Scheme

    Directory of Open Access Journals (Sweden)

    Hojjat Salehinejad

    2012-01-01

    Full Text Available The orthogonal frequency division multiplexing (OFDM modulation technique is one of the key strategies for multiuser signal transmission especially in smart grids and wind farms. This paper introduces an approach for peak-to-average power ratio (PAPR reduction of such signals based on novel global harmony search (NGHS and partial transmit sequence (PTS schemes. In PTS technique, the data block to be transmitted is partitioned into disjoint subblocks, which are combined using phase factors to minimize PAPR. The PTS requires an exhaustive search over all combinations of allowed phase factors. Therefore, with respect to the fast implementation and simplicity of NGHS technique, we could achieve significant reduction of PAPR.

  11. The source of prehistoric obsidian artefacts from the Polynesian outlier of Taumako in the Solomon Islands

    Energy Technology Data Exchange (ETDEWEB)

    Leach, Foss [Otago Univ., Dunedin (New Zealand). Dept. of Anthropology

    1985-01-01

    Six obsidian artefacts from the Polynesian outlier of Taumako in the Solomon Islands dating to between 500 and 1000 B.C. were analysed for trace elements by the PIXE-PIGME method. Four are shown to derive from Vanuatu, but the remaining two artefacts do not match any of the known 66 sources in the Pacific region. Continuing difficulties with the methodology of Pacific obsidian sourcing are discussed. 14 refs; 2 tables.

  12. Research into tin and arsenical copper artefacts using nuclear analytical techniques

    International Nuclear Information System (INIS)

    Grant, M.R.

    1995-01-01

    This study includes the chemical analysis, sourcing and historical metallurgy of tin and arsenical copper artefacts discovered at Rooiberg and elsewhere in the Northern Transvaal and at Great Zimbabwe. A complete chemical analysis method for tin and cassiterite is presented, based on INAA (instrumental neutron activation analysis) and supplemented by PIXE or AAS for elements such as lead, bismuth and niobium. This is apparently the first study in which tin artefacts were analysed by INAA without chemical processing of the samples. INAA and PIXE returned the same results when a homogenized tin alloy block was analysed, but the structure and distribution of hardhead phases appear to produce an iron quantification problem in ancient tin. Ores and slags were analysed for light matrix elements by XRF or PIXE and INAA for the heavy trace metals. 108 refs., 24 figs., 130 tabs

  13. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography—An in vivo and in vitro study

    Energy Technology Data Exchange (ETDEWEB)

    Schaafsma, Joanna D., E-mail: j.d.schaafsma@umcutrecht.nl [Department of Neurology, Rudolf Magnus Institute of Neuroscience, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Velthuis, Birgitta K., E-mail: b.k.velthuis@umcutrecht.nl [Imaging Division, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Vincken, Koen L., E-mail: koen@isi.uu.nl [Image Sciences Institute, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Kort, Gerard A.P. de, E-mail: g.a.p.dekort@umcutrecht.nl [Imaging Division, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Rinkel, Gabriel J.E., E-mail: g.j.e.rinkel@umcutrecht.nl [Department of Neurology, Rudolf Magnus Institute of Neuroscience, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands); Bartels, Lambertus W., E-mail: w.bartels@umcutrecht.nl [Image Sciences Institute, University Medical Centre, PO Box 85500, 3508 GA Utrecht (Netherlands)

    2014-05-15

    Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0 Tesla. Materials and methods: We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0 Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0 Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Results: Coil artefacts disturbed assessments less frequently at 3.0 Tesla than at 1.5 Tesla (RR: 0.3; 95%CI: 0.1–0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7 mm; 95%CI: 0.3–1.1) and larger than on IA-DSA (difference: 1.0 mm; 95%CI: 0.6–1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23–0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19–0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0 Tesla than at 1.5 Tesla. The echo-time influenced artefact size more than the read-out gradient. Conclusions: Artefacts were not larger, but smaller at 3.0 Tesla because a shorter echo-time at 3.0 Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0 Tesla, occlusion levels were similar for both field strengths.

  14. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography—An in vivo and in vitro study

    International Nuclear Information System (INIS)

    Schaafsma, Joanna D.; Velthuis, Birgitta K.; Vincken, Koen L.; Kort, Gerard A.P. de; Rinkel, Gabriel J.E.; Bartels, Lambertus W.

    2014-01-01

    Objective: To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0 Tesla. Materials and methods: We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0 Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0 Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Results: Coil artefacts disturbed assessments less frequently at 3.0 Tesla than at 1.5 Tesla (RR: 0.3; 95%CI: 0.1–0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7 mm; 95%CI: 0.3–1.1) and larger than on IA-DSA (difference: 1.0 mm; 95%CI: 0.6–1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23–0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19–0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0 Tesla than at 1.5 Tesla. The echo-time influenced artefact size more than the read-out gradient. Conclusions: Artefacts were not larger, but smaller at 3.0 Tesla because a shorter echo-time at 3.0 Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0 Tesla, occlusion levels were similar for both field strengths

  15. Artefacts induced by coiled intracranial aneurysms on 3.0-Tesla versus 1.5-Tesla MR angiography--An in vivo and in vitro study.

    Science.gov (United States)

    Schaafsma, Joanna D; Velthuis, Birgitta K; Vincken, Koen L; de Kort, Gerard A P; Rinkel, Gabriel J E; Bartels, Lambertus W

    2014-05-01

    To compare metal-induced artefacts from coiled intracranial aneurysms on 3.0-Tesla and 1.5-Tesla magnetic resonance angiography (MRA), since concerns persist on artefact enlargement at 3.0Tesla. We scanned 19 patients (mean age 53; 16 women) with 20 saccular aneurysms treated with coils only, at 1.5 and 3.0Tesla according to standard clinical 3D TOF-MRA protocols containing a shorter echo-time but weaker read-out gradient at 3.0Tesla in addition to intra-arterial digital subtraction angiography (IA-DSA). Per modality two neuro-radiologists assessed the occlusion status, measured residual flow, and indicated whether coil artefacts disturbed this assessment on MRA. We assessed relative risks for disturbance by coil artefacts, weighted kappa's for agreement on occlusion levels, and we compared remnant sizes. For artefact measurements, a coil model was created and scanned with the same protocols followed by 2D MR scans with variation of echo-time and read-out gradient strength. Coil artefacts disturbed assessments less frequently at 3.0Tesla than at 1.5Tesla (RR: 0.3; 95%CI: 0.1-0.8). On 3.0-Tesla MRA, remnants were larger than on 1.5-Tesla MRA (difference: 0.7mm; 95%CI: 0.3-1.1) and larger than on IA-DSA (difference: 1.0mm; 95%CI: 0.6-1.5) with similar agreement on occlusion levels with IA-DSA for both field strengths (κ 0.53; 95%CI: 0.23-0.84 for 1.5-Tesla MRA and IA-DSA; κ 0.47; 95%CI: 0.19-0.76 for 3.0-Tesla MRA and IA-DSA). Coil model artefacts were smaller at 3.0Tesla than at 1.5Tesla. The echo-time influenced artefact size more than the read-out gradient. Artefacts were not larger, but smaller at 3.0Tesla because a shorter echo-time at 3.0Tesla negated artefact enlargement. Despite smaller artefacts and larger remnants at 3.0Tesla, occlusion levels were similar for both field strengths. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias; Scholz, Bernhard; Royalty, Kevin

    2017-01-01

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  17. Evaluation of a metal artifact reduction algorithm applied to post-interventional flat detector CT in comparison to pre-treatment CT in patients with acute subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Mennecke, Angelika; Svergun, Stanislav; Doerfler, Arnd; Struffert, Tobias [University of Erlangen-Nuremberg, Department of Neuroradiology, Erlangen (Germany); Scholz, Bernhard [Siemens Healthcare GmbH, Forchheim (Germany); Royalty, Kevin [Siemens Medical Solutions, USA, Inc., Hoffman Estates, IL (United States)

    2017-01-15

    Metal artefacts can impair accurate diagnosis of haemorrhage using flat detector CT (FD-CT), especially after aneurysm coiling. Within this work we evaluate a prototype metal artefact reduction algorithm by comparison of the artefact-reduced and the non-artefact-reduced FD-CT images to pre-treatment FD-CT and multi-slice CT images. Twenty-five patients with acute aneurysmal subarachnoid haemorrhage (SAH) were selected retrospectively. FD-CT and multi-slice CT before endovascular treatment as well as FD-CT data sets after treatment were available for all patients. The algorithm was applied to post-treatment FD-CT. The effect of the algorithm was evaluated utilizing the pre-post concordance of a modified Fisher score, a subjective image quality assessment, the range of the Hounsfield units within three ROIs, and the pre-post slice-wise Pearson correlation. The pre-post concordance of the modified Fisher score, the subjective image quality, and the pre-post correlation of the ranges of the Hounsfield units were significantly higher for artefact-reduced than for non-artefact-reduced images. Within the metal-affected slices, the pre-post slice-wise Pearson correlation coefficient was higher for artefact-reduced than for non-artefact-reduced images. The overall diagnostic quality of the artefact-reduced images was improved and reached the level of the pre-interventional FD-CT images. The metal-unaffected parts of the image were not modified. (orig.)

  18. A Comparative Study of Physiological Monitoring with a Wearable Opto-Electronic Patch Sensor (OEPS for Motion Reduction

    Directory of Open Access Journals (Sweden)

    Abdullah Alzahrani

    2015-06-01

    Full Text Available This paper presents a comparative study in physiological monitoring between a wearable opto-electronic patch sensor (OEPS comprising a three-axis Microelectromechanical systems (MEMs accelerometer (3MA and commercial devices. The study aims to effectively capture critical physiological parameters, for instance, oxygen saturation, heart rate, respiration rate and heart rate variability, as extracted from the pulsatile waveforms captured by OEPS against motion artefacts when using the commercial probe. The protocol involved 16 healthy subjects and was designed to test the features of OEPS, with emphasis on the effective reduction of motion artefacts through the utilization of a 3MA as a movement reference. The results show significant agreement between the heart rates from the reference measurements and the recovered signals. Significance of standard deviation and error of mean yield values of 2.27 and 0.65 beats per minute, respectively; and a high correlation (0.97 between the results of the commercial sensor and OEPS. T, Wilcoxon and Bland-Altman with 95% limit of agreement tests were also applied in the comparison of heart rates extracted from these sensors, yielding a mean difference (MD: 0.08. The outcome of the present work incites the prospects of OEPS on physiological monitoring during physical activities.

  19. Social Analysis in Development Interventions: Policy Artefact or Constructive Transformation?

    Directory of Open Access Journals (Sweden)

    SUSANNA PRICE

    2012-02-01

    Full Text Available Recently attention has focused on the role of social researchers in the processes of construction and transmission of knowledge about global poverty and its reduction. This paper examines some of the formative efforts by pioneering social researchers in development institutions to step into the realm of policy making to construct processes for project preparation and management through social analysis. Before 1970 development planners invoked ‘social' or ‘human' factors only as an excuse to explain away project failures - they designed and implemented development projects in the absence of any strategies or regulatory frameworks for managing their social impacts. Recognizing that project investments represent induced change and constitute a social process in themselves, pioneering social researchers constructed policies and procedures to introduce sociological content and method into the project cycle and so re-order social outcomes. Were such constructs merely policy artefacts? Even as the constructs helped to shift the statements of the development discourse towards ‘people oriented' poverty reduction, new modalities appeared which tested the limits of the agreed methods. Institutions may forget, neglect, contest or re-write the documents if in perceived conflict with the institutional ‘core business'. Yet those pioneering efforts created institutional space for, and understanding of, social analysis, with a measure of flow-on international recognition. Tracking social analysis in several international institutions and in a significant emerging economy, China, this paper highlights not only a history full of lessons to be learned where social analysis is not practiced systematically but also outlines some future challenges.

  20. Evidence of metallic plating on archaeological artefacts by voltammetry of microparticles

    Czech Academy of Sciences Publication Activity Database

    Ottenwelter, Estelle; Costa, V.

    2015-01-01

    Roč. 57, č. 3 (2015), s. 497-504 ISSN 0003-813X Institutional support: RVO:67985912 Keywords : metallic plating * voltammetry of microparticles * non-invasive analysis * medieval period * archaeological artefacts Subject RIV: AC - Archeology, Anthropology, Ethnology Impact factor: 1.364, year: 2015

  1. Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Baissalov, R.; Sandison, G.A.; Rewcastle, J.C. [Department of Medical Physics, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 2 Department of Physics and Astronomy, University of Calgary, Calgary T2N 2N4 (Canada); Donnelly, B.J. [Department of Surgery, Tom Baker Cancer Center, Calgary, Canada, T2N 4N2 4 Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Saliken, J.C. [Department of Surgery, Tom Baker Cancer Center, Calgary T2N 4N2 (Canada); Department of Diagnostic Imaging, Foothills Hospital, Calgary T2N 2T7 (Canada); McKinnon, J.G. [Department of Surgery, Foothills Hospital, Calgary T2N 2T7 (Canada); Muldrew, K. [Department of Surgery, Faculty of Medicine, University of Calgary, Calgary T2N 2T7 (Canada)

    2000-05-01

    Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey-scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high-density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent. (author)

  2. Suppression of high-density artefacts in x-ray CT images using temporal digital subtraction with application to cryotherapy

    International Nuclear Information System (INIS)

    Baissalov, R.; Sandison, G.A.; Rewcastle, J.C.; Donnelly, B.J.; Saliken, J.C.; McKinnon, J.G.; Muldrew, K.

    2000-01-01

    Image guidance in cryotherapy is usually performed using ultrasound. Although not currently in routine clinical use, x-ray CT imaging is an alternative means of guidance that can display the full 3D structure of the iceball, including frozen and unfrozen regions. However, the quality of x-ray CT images is compromised by the presence of high-density streak artefacts. To suppress these artefacts we applied temporal digital subtraction (TDS). This TDS method has the added advantage of improving the grey-scale contrast between frozen and unfrozen tissue in the CT images. Two sets of CT images were taken of a phantom material, cryoprobes and a urethral warmer (UW) before and during the cryoprobe freeze cycle. The high-density artefacts persisted in both image sets. TDS was performed on these two image sets using the corresponding mask image of unfrozen material and the same geometrical configuration of the cryoprobes and the UW. The resultant difference image had a significantly reduced artefact content. Thus TDS can be used to significantly suppress or eliminate high-density CT streak artefacts without reducing the metallic content of the cryoprobes. In vivo study needs to be conducted to establish the utility of this TDS procedure for CT assisted prostate or liver cryotherapy. Applying TDS in x-ray CT guided cryotherapy will facilitate estimation of the number and location of all frozen and unfrozen regions, potentially making cryotherapy safer and less operator dependent. (author)

  3. Clinical learning environments: place, artefacts and rhythm.

    Science.gov (United States)

    Sheehan, Dale; Jowsey, Tanisha; Parwaiz, Mariam; Birch, Mark; Seaton, Philippa; Shaw, Susan; Duggan, Alison; Wilkinson, Tim

    2017-10-01

    Health care practitioners learn through experience in clinical environments in which supervision is a key component, but how that learning occurs outside the supervision relationship remains largely unknown. This study explores the environmental factors that inform and support workplace learning within a clinical environment. An observational study drawing on ethnographic methods was undertaken in a general medicine ward. Observers paid attention to interactions among staff members that involved potential teaching and learning moments that occurred and were visible in the course of routine work. General purpose thematic analysis of field notes was undertaken. A total of 376 observations were undertaken and documented. The findings suggest that place (location of interaction), rhythm (regularity of activities occurring in the ward) and artefacts (objects and equipment) were strong influences on the interactions and exchanges that occurred. Each of these themes had inherent tensions that could promote or inhibit engagement and therefore learning opportunities. Although many learning opportunities were available, not all were taken up or recognised by the participants. We describe and make explicit how the natural environment of a medical ward and flow of work through patient care contribute to the learning architecture, and how this creates or inhibits opportunities for learning. Awareness of learning opportunities was often tacit and not explicit for either supervisor or learner. We identify strategies through which tensions inherent within space, artefacts and the rhythms of work can be resolved and learning opportunities maximised. © 2017 John Wiley & Sons Ltd and The Association for the Study of Medical Education.

  4. The reduction of background signal in bismuth germanate scintillators

    International Nuclear Information System (INIS)

    Lewis, T.A.

    1986-07-01

    Bismuth germanate (BGO) is one of several new scintillator materials developed in recent years. It has similar energy resolution (6-8%) to sodium iodide (NaI) but it is non-hygroscopic, has a much better Peak-to-Compton ratio and a stopping power about 2.3 times greater than NaI. For counting activated foils it represents an improvement on NaI for high efficiency counting where the resolution of a germanium spectrometer is not required. Two scintillators bought for this purpose were found to have a higher than expected background signal between 500 keV and 2 MeV which was traced to Bi207, an active isotope of bismuth with a 38 year half-life and not listed as occurring naturally. Reference to the manufacturer showed all crystals to be similarly contaminated. It is speculated that this active isotope arises from cosmic proton activation of associated lead in the ore from which the bismuth is extracted. Although not confirmed rigorously it has been shown that bismuth extracted from ore with a low lead content does not contain Bi207. Scintillators have been manufactured from uncontaminated material and reductions in the background signal of more than an order of magnitude have been achieved. This reduction will be of immediate benefit for monitoring nickel foils (fast flux monitors) activated in zero-energy reactors and should also permit the exploitation of other low probability reactions previously not thought to be feasible. (author)

  5. Reduction of EMC Emissions in Mixed Signal Integrated Circuits with Embedded LIN Driver

    Directory of Open Access Journals (Sweden)

    P. Hartl

    2016-06-01

    Full Text Available This paper describes several methods for reduction of electromagnetic emissions (EME of mixed signal integrated circuits (IC. The focus is on the impact that a LIN bus communication block has on a complex IC which contains analog blocks, noisy digital block, micro-core (µC and several types of memories. It is used in an automotive environment, where EMC emission reduction is one of the key success factors. Several proposed methods for EME reduction are described and implemented on three test chips. These methods include current consumption reduction, internal on-chip decoupling, ground separation and different linear voltage regulator topologies. Measurement results of several fabricated test chips are shown and discussed.

  6. The use of radiation in the study of cultural heritage artefacts

    International Nuclear Information System (INIS)

    Creagh, Dudley; Otieno-Alego, Vincent; Treasure, Alana; Kubik, Maria; Hallam, David

    2017-01-01

    Patrons of art galleries and museums, tourists visiting historic buildings, and sightseers viewing archaeological sites are generally unaware of the extent to which science and technology has contributed to the value of what they see. Many countries rely on cultural tourism to generate national wealth. The use of radiation of many kinds to assist in the conservation/restoration of cultural heritage artefacts is described in this paper. In particular, the paper will describe studies of the pigments used in historic Australian Indigenous art, the degradation of manuscripts written using iron-gall inks, the protection of statues against corrosion and the selection of lubricants for use in old machinery. - Highlights: • We describe a diverse range of techniques used to study cultural heritage artefacts. • IR X-ray and particle beam techniques were used to study: • The structure and composition of Australian Indigenous bark paintings. • The effects of iron-gall inks on parchment. • The results of corrosion and corrosion protection in machinery and vehicles.

  7. EVALUATING AND REFINING THE ‘ENTERPRISE ARCHITECTURE AS STRATEGY’ APPROACH AND ARTEFACTS

    Directory of Open Access Journals (Sweden)

    M. De Vries

    2012-01-01

    Full Text Available

    ENGLISH ABSTRACT: Enterprise Architecture (EA is a new discipline that has emerged from the need to create a holistic view of an enterprise, and thereby to discover business/IT integration and alignment opportunities across enterprise structures. Previous EA value propositions that merely focus on IT cost reductions will no longer convince management to invest in EA. Today, EA should enable business strategy in the organisation to create value. This resides in the ability to do enterprise optimisation through process standardisation and integration. In order to do this, a new approach is required to integrate EA into the strategy planning process of the organisation.
    This article explores the use of three key artefacts – operating models, core diagrams, and an operating maturity assessment as defined by Ross, Weill & Robertson [1] – as the basis of this new approach. Action research is applied to a research group to obtain qualitative feedback on the practicality of the artefacts.

    AFRIKAANSE OPSOMMING: Ondernemingsargitektuur (OA is ’n nuwe dissipline wat ontstaan het uit die behoefte om ’n holistiese perspektief van ’n onderneming te skep om sodoende besigheid/IT-integrasie en - belyningsgeleenthede regoor ondernemingstrukture te ontdek. Vorige OA waardeaanbiedings wat hoofsaaklik gefokus het op IT kostebesparings sal bestuur nie meer kan oorreed om in OA te belê nie. Vandag behoort OA bevoegdheid te gee aan ondernemingstrategie om werklik waarde te skep. Hierdie bevoegdheid lê gesetel in ondernemingsoptimering deur middel van prosesstandaardisasie en -integrasie. ’n Nuwe benadering word benodig ten einde OA te integreer met die strategiese beplanningsproses van die organisasie.
    Hierdie artikel ondersoek die gebruik van drie artefakte – operasionele modelle, kerndiagramme, en operasionele volwassenheidsassessering soos gedefinieer deur Ross, Weill & Robertson [1] – as die basis van hierdie nuwe benadering

  8. Analysis of Paper reduction schemes to develop selection criteria for ofdm signals

    International Nuclear Information System (INIS)

    Abro, F.R.

    2015-01-01

    This paper presents a review of different PAPR (Peak to Average Power Ratio) reduction schemes of OFDM (Orthogonal Frequency Division Multiplexing) signals. The schemes that have been considered include Clipping and Filtering, Coding, ACE (Active Contstellation Extension), SLM (Selected Mapping), PTS (Partial Transmit Sequence), TI (Tone Injection) and TR (Tone Reservation). A comparative analysis has been carried out qualitatively. It has been demonstrated how these schemes can be combined with MIMO (Multiple Input Multiple Output) technologies. Finally, criteria for selection of PAPR reduction schemes of OFDM systems are discussed. (author)

  9. Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws.

    Science.gov (United States)

    Filli, Lukas; Marcon, Magda; Scholz, Bernhard; Calcagni, Maurizio; Finkenstädt, Tim; Andreisek, Gustav; Guggenberger, Roman

    2014-12-01

    The aim of this study was to evaluate a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography (FDCT) of scaphoid fixation screws. FDCT has gained interest in imaging small anatomic structures of the appendicular skeleton. Angiographic C-arm systems with flat detectors allow fluoroscopy and FDCT imaging in a one-stop procedure emphasizing their role as an ideal intraoperative imaging tool. However, FDCT imaging can be significantly impaired by artefacts induced by fixation screws. Following ethical board approval, commercially available scaphoid fixation screws were inserted into six cadaveric specimens in order to fix artificially induced scaphoid fractures. FDCT images corrected with the algorithm were compared to uncorrected images both quantitatively and qualitatively by two independent radiologists in terms of artefacts, screw contour, fracture line visibility, bone visibility, and soft tissue definition. Normal distribution of variables was evaluated using the Kolmogorov-Smirnov test. In case of normal distribution, quantitative variables were compared using paired Student's t tests. The Wilcoxon signed-rank test was used for quantitative variables without normal distribution and all qualitative variables. A p value of < 0.05 was considered to indicate statistically significant differences. Metal artefacts were significantly reduced by the correction algorithm (p < 0.001), and the fracture line was more clearly defined (p < 0.01). The inter-observer reliability was "almost perfect" (intra-class correlation coefficient 0.85, p < 0.001). The prototype correction algorithm in FDCT for metal artefacts induced by scaphoid fixation screws may facilitate intra- and postoperative follow-up imaging. Flat detector computed tomography (FDCT) is a helpful imaging tool for scaphoid fixation. The correction algorithm significantly reduces artefacts in FDCT induced by scaphoid fixation screws. This may facilitate intra

  10. Are osseous artefacts a window to perishable material culture? Implications of an unusually complex bone tool from the Late Pleistocene of East Timor.

    Science.gov (United States)

    O'Connor, S; Robertson, G; Aplin, K P

    2014-02-01

    We report the discovery of an unusually complex and regionally unique bone artefact in a Late Pleistocene archaeological assemblage (c. 35 ka [thousands of years ago]) from the site of Matja Kuru 2 on the island of Timor, in Wallacea. The artefact is interpreted as the broken butt of a formerly hafted projectile point, and it preserves evidence of a complex hafting mechanism including insertion into a shaped or split shaft, a complex pattern of binding including lateral stabilization of the cordage within a bilateral series of notches, and the application of mastic at several stages in the hafting process. The artefact provides the earliest direct evidence for the use of this combination of hafting technologies in the wider region of Southeast Asia, Wallacea, Melanesia and Australasia, and is morphologically unparallelled in deposits of any age. By contrast, it bears a close morphological resemblance to certain bone artefacts from the Middle Stone Age of Africa and South Asia. Examination of ethnographic projectile technology from the region of Melanesia and Australasia shows that all of the technological elements observed in the Matja Kuru 2 artefact were in use historically in the region, including the unusual feature of bilateral notching to stabilize a hafted point. This artefact challenges the notion that complex bone-working and hafting technologies were a relatively late innovation in this part of the world. Moreover, its regional uniqueness encourages us to abandon the perception of bone artefacts as a discrete class of material culture, and to adopt a new interpretative framework in which they are treated as manifestations of a more general class of artefacts that more typically were produced on perishable raw materials including wood. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  11. Planning Uncertainty: Creating an Artefact Density Index for North Yorkshire, England

    Directory of Open Access Journals (Sweden)

    Nick Boldrini

    2007-04-01

    Full Text Available Portable antiquities (sometimes known as small finds or chance finds are often recorded within most Historic Environment Records to a spurious level of precision. For example, finds located only within a parish, or general area, are often mapped within GIS systems to exact points. Similarly, finds known only to the nearest kilometre square are usually mapped in the bottom left-hand corner of the square in GIS. While such mappings can be taken into account to some extent when trying to assess the archaeological potential of an area, the degree to which the records may give distorted views of the archaeological potential of an area may not be fully appreciated. This may mean that the full archaeological impacts of development may not be taken into account during development control decision making. This article looks at an alternative method for mapping such finds in order to produce an Artefact Density Index for areas, which more usefully reflects the pattern of activities across the landscape. The Artefact Density Index (ADI was divided to reflect broad archaeological periods (e.g. Roman, medieval etc., as well as broad artefact types (e.g. weapons, tools etc.. The ADI was based on combining weighted values for finds types, with the weight reflecting the precision of the location of the finds (i.e. finds recorded only at parish level will be given less weight than those recorded more precisely. An ADI was developed for a sub-area of the North Yorkshire County Council HER area, and also incorporated data from the Portable Antiquities scheme as a case study for the project.

  12. Analysis of artefacts and detail resolution of lung MRI with breath-hold T1-weighted gradient-echo and T2-weighted fast spin-echo sequences with respiratory triggering

    International Nuclear Information System (INIS)

    Biederer, J.; Reuter, M.; Both, M.; Grimm, J.; Heller, M.; Muhle, C.; Graessner, J.

    2002-01-01

    The aim of this study was to evaluate feasibility and limitations of two MR sequences for imaging of the lung using a semi-quantitative rating scale. Ten healthy volunteers were assessed with a breath-hold T1-weighted gradient-recalled-echo (TR/TE=129/2.2 ms, matrix 173 x 256) and a T2-weighted turbo spin-echo (TSE) sequence with respiratory triggering (TR/TE=3000-5000/120 ms, matrix 270 x 512) in axial 6-mm slices. The T1-weighted GRE protocol included a pre-saturation pulse over the mediastinal structures. Artefacts and resolution of vessel/airway structures in each lung segment were evaluated by two observers (10 volunteers, 180 segments). Cardiac and vessel pulsation artefacts predominated on T1-weighted GRE, respiration artefacts on T2-weighted TSE (lingula and middle lobe). Pre-saturation of the mediastinum reduced pulsation artefacts on T1-weighted GRE. T1-weighted GRE images were improved by bright flow signal of vessels, whereas image quality of T2-weighted TSE was reduced by black-blood effects in central parts of the lung. Delineation of lung periphery and the mediastinum was superior with T2-weighted TSE. Segmental/sub-segmental vessels (up to fourth/fifth order) and bronchi (up to third order) were identified. All 180 lung segments were imaged in diagnostic quality with at least one of the two sequences (T1-weighted GRE not diagnostic in 9 of 180, T2-weighted TSE in 4 of 180). Both sequences were found to be complementary: superior identification of gross lung anatomy with T1-weighted GRE and higher detail resolution in the periphery and the mediastinum with T2-weighted TSE. (orig.)

  13. The characterisation of non-evaporable getters by Auger electron spectroscopy Analytical potential and artefacts

    CERN Document Server

    Scheuerlein, C; Taborelli, M

    2002-01-01

    The surfaces of getter materials are particularly difficult to analyse because of their high chemical reactivity. The results obtained can be strongly influenced by the experimental set-up and procedures. In this paper the experimental influence on the Auger electron spectroscopy results is discussed, based on the measurements of more than 100 different non-evaporable getter (NEG) materials. There are four typical changes in the Auger electron spectra when a NEG becomes activated. The oxygen peak intensity decreases, the shape of the metal peaks changes, the carbon peak shape changes shape and intensity and a chlorine peak occurs. All these changes are affected by instrumental artefacts. The Zr-MNV peak shape changes occurring during the reduction of ZrO2 are well suited to determine the onset of NEG activation, while the slope with which the O-KLL peak intensity decreases in a certain temperature range is a better criterion for the determination of the temperature at which activation is complete. The O-KLL i...

  14. FEL small signal gain reduction due to phase error of undulator

    International Nuclear Information System (INIS)

    Jia Qika

    2002-01-01

    The effects of undulator phase errors on the Free Electron Laser small signal gain is analyzed and discussed. The gain reduction factor due to the phase error is given analytically for low-gain regimes, it shows that degradation of the gain is similar to that of the spontaneous radiation, has a simple exponential relation with square of the rms phase error, and the linear variation part of phase error induces the position shift of maximum gain. The result also shows that the Madey's theorem still hold in the presence of phase error. The gain reduction factor due to the phase error for high-gain regimes also can be given in a simple way

  15. Angiographic and artefact-free computed tomography imaging of experimental aneurysms embolised with hydrogel filaments

    Energy Technology Data Exchange (ETDEWEB)

    McCoy, Mark R. [Paracelsus Medical University, Department of Radiology and Magnetic Resonance Tomography, Christian Doppler Clinic, Salzburg (Austria); Cruise, Gregory M. [MicroVention Terumo, Aliso Viejo, CA (United States); Killer, Monika [Paracelsus Medical University, Department of Neurology/Neuroscience Institute, Christian Doppler Clinic, Salzburg (Austria)

    2010-04-15

    We compared experimental rabbit carotid bifurcation aneurysms embolised with platinum coils or hydrogel filaments by using digital subtraction angiography (DSA) and computed tomography angiography (CTA). Embolisation was performed using platinum coils (n = 2), hydrogel filaments loaded with iodine (n = 3) and hydrogel filaments loaded with barium sulphate (n = 3). In one case, a stent was deployed in the parent vessel to determine the effect of hydrogel filaments on stent visualisation. DSA evaluations occurred immediately post-treatment. CTA evaluations occurred at 0-13 weeks post-treatment. The DSA and CTA images were evaluated for the lack of artefacts and the visibilities of the embolic mass, individual coils and residual flow in the aneurysm sac and neck. The DSA results were largely concordant among the three groups. The embolic masses were readily evident with some individual coils being distinguished. In the aneurysms embolised with hydrogel filaments, visualisation of the individual coils, residual flow and stent with minor or no artefacts was possible using CTA. On the other hand, the beam hardening artefacts precluded analysis of aneurysms embolised with platinum coils. CTA-compatible embolic devices could have wide applications in diverse locations throughout the vasculature, particularly in combination with stents or stent grafts. (orig.)

  16. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

    International Nuclear Information System (INIS)

    Guzinski, Maciej; Waszczuk, Lukasz; Sasiadek, Marek J.

    2016-01-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. (orig.)

  17. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations

    Energy Technology Data Exchange (ETDEWEB)

    Guzinski, Maciej; Waszczuk, Lukasz; Sasiadek, Marek J. [Wroclaw Medical University, Department of General Radiology, Interventional Radiology and Neuroradiology, Wroclaw (Poland)

    2016-10-15

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. (orig.)

  18. Risk Identification in a Smart Monitoring System Used to Preserve Artefacts Based on Textile Materials

    Science.gov (United States)

    Diaconescu, V. D.; Scripcariu, L.; Mătăsaru, P. D.; Diaconescu, M. R.; Ignat, C. A.

    2018-06-01

    Exhibited textile-materials-based artefacts can be affected by the environmental conditions. A smart monitoring system that commands an adaptive automatic environment control system is proposed for indoor exhibition spaces containing various textile artefacts. All exhibited objects are monitored by many multi-sensor nodes containing temperature, relative humidity and light sensors. Data collected periodically from the entire sensor network is stored in a database and statistically processed in order to identify and classify the environment risk. Risk consequences are analyzed depending on the risk class and the smart system commands different control measures in order to stabilize the indoor environment conditions to the recommended values and prevent material degradation.

  19. Transverse grooved artefacts from southwestern Asia and northern Eurasia: Common traits and the reconstruction of function

    Directory of Open Access Journals (Sweden)

    Irina Usacheva

    2016-10-01

    Full Text Available Transverse grooved artefacts (TGA appeared as a new cultural element in Mesolithic-Proto-Neolithic sites in southwestern Asia. We know of similar artefacts from northern Africa. Hundreds of TGA have also been found in northern Eurasia. Some common traits were found in specimens from far apart territories, such as the non-abrasive heat-resistant nature of the raw materials, specificity of fragmentation without any signs of physical impact, the standard size of the grooves, association with a specific type of landscape, the similar economic level of the societies with which the items are associated, and use-wear marks in the grooves. Based on these regularities we can speak of a single main function for these artefacts which support the earlier reconstruction of R.L. and R.S. Solecki, suggesting that grooved stones were used for straightening cane and reed shafts under heating. Other evidence and traces that have been identified on the surface of TGA outside the groove could be associated with a variety of additional functions.

  20. Calibrating the X-ray attenuation of liquid water and correcting sample movement artefacts during in operando synchrotron X-ray radiographic imaging of polymer electrolyte membrane fuel cells.

    Science.gov (United States)

    Ge, Nan; Chevalier, Stéphane; Hinebaugh, James; Yip, Ronnie; Lee, Jongmin; Antonacci, Patrick; Kotaka, Toshikazu; Tabuchi, Yuichiro; Bazylak, Aimy

    2016-03-01

    Synchrotron X-ray radiography, due to its high temporal and spatial resolutions, provides a valuable means for understanding the in operando water transport behaviour in polymer electrolyte membrane fuel cells. The purpose of this study is to address the specific artefact of imaging sample movement, which poses a significant challenge to synchrotron-based imaging for fuel cell diagnostics. Specifically, the impact of the micrometer-scale movement of the sample was determined, and a correction methodology was developed. At a photon energy level of 20 keV, a maximum movement of 7.5 µm resulted in a false water thickness of 0.93 cm (9% higher than the maximum amount of water that the experimental apparatus could physically contain). This artefact was corrected by image translations based on the relationship between the false water thickness value and the distance moved by the sample. The implementation of this correction method led to a significant reduction in false water thickness (to ∼0.04 cm). Furthermore, to account for inaccuracies in pixel intensities due to the scattering effect and higher harmonics, a calibration technique was introduced for the liquid water X-ray attenuation coefficient, which was found to be 0.657 ± 0.023 cm(-1) at 20 keV. The work presented in this paper provides valuable tools for artefact compensation and accuracy improvements for dynamic synchrotron X-ray imaging of fuel cells.

  1. Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Finkenstaedt, Tim; Andreisek, Gustav; Guggenberger, Roman [University Hospital of Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); Marcon, Magda [University Hospital of Zurich, Department of Diagnostic and Interventional Radiology, Zurich (Switzerland); University of Udine, Institute of Diagnostic Radiology, Department of Medical and Biological Sciences, Udine (Italy); Scholz, Bernhard [Imaging and Therapy Division, Siemens AG, Healthcare Sector, Forchheim (Germany); Calcagni, Maurizio [University Hospital of Zurich, Division of Plastic Surgery and Hand Surgery, Zurich (Switzerland)

    2014-12-15

    The aim of this study was to evaluate a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography (FDCT) of scaphoid fixation screws. FDCT has gained interest in imaging small anatomic structures of the appendicular skeleton. Angiographic C-arm systems with flat detectors allow fluoroscopy and FDCT imaging in a one-stop procedure emphasizing their role as an ideal intraoperative imaging tool. However, FDCT imaging can be significantly impaired by artefacts induced by fixation screws. Following ethical board approval, commercially available scaphoid fixation screws were inserted into six cadaveric specimens in order to fix artificially induced scaphoid fractures. FDCT images corrected with the algorithm were compared to uncorrected images both quantitatively and qualitatively by two independent radiologists in terms of artefacts, screw contour, fracture line visibility, bone visibility, and soft tissue definition. Normal distribution of variables was evaluated using the Kolmogorov-Smirnov test. In case of normal distribution, quantitative variables were compared using paired Student's t tests. The Wilcoxon signed-rank test was used for quantitative variables without normal distribution and all qualitative variables. A p value of < 0.05 was considered to indicate statistically significant differences. Metal artefacts were significantly reduced by the correction algorithm (p < 0.001), and the fracture line was more clearly defined (p < 0.01). The inter-observer reliability was ''almost perfect'' (intra-class correlation coefficient 0.85, p < 0.001). The prototype correction algorithm in FDCT for metal artefacts induced by scaphoid fixation screws may facilitate intra- and postoperative follow-up imaging. (orig.)

  2. Evaluation of a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography of scaphoid fixation screws

    International Nuclear Information System (INIS)

    Filli, Lukas; Finkenstaedt, Tim; Andreisek, Gustav; Guggenberger, Roman; Marcon, Magda; Scholz, Bernhard; Calcagni, Maurizio

    2014-01-01

    The aim of this study was to evaluate a prototype correction algorithm to reduce metal artefacts in flat detector computed tomography (FDCT) of scaphoid fixation screws. FDCT has gained interest in imaging small anatomic structures of the appendicular skeleton. Angiographic C-arm systems with flat detectors allow fluoroscopy and FDCT imaging in a one-stop procedure emphasizing their role as an ideal intraoperative imaging tool. However, FDCT imaging can be significantly impaired by artefacts induced by fixation screws. Following ethical board approval, commercially available scaphoid fixation screws were inserted into six cadaveric specimens in order to fix artificially induced scaphoid fractures. FDCT images corrected with the algorithm were compared to uncorrected images both quantitatively and qualitatively by two independent radiologists in terms of artefacts, screw contour, fracture line visibility, bone visibility, and soft tissue definition. Normal distribution of variables was evaluated using the Kolmogorov-Smirnov test. In case of normal distribution, quantitative variables were compared using paired Student's t tests. The Wilcoxon signed-rank test was used for quantitative variables without normal distribution and all qualitative variables. A p value of < 0.05 was considered to indicate statistically significant differences. Metal artefacts were significantly reduced by the correction algorithm (p < 0.001), and the fracture line was more clearly defined (p < 0.01). The inter-observer reliability was ''almost perfect'' (intra-class correlation coefficient 0.85, p < 0.001). The prototype correction algorithm in FDCT for metal artefacts induced by scaphoid fixation screws may facilitate intra- and postoperative follow-up imaging. (orig.)

  3. PET/CT Atlas on Quality Control and Image Artefacts

    International Nuclear Information System (INIS)

    2014-01-01

    Combined positron emission tomography (PET)/computed tomography (CT) imaging has become a routine procedure in diagnostic radiology and nuclear medicine. The clinical review of both PET and PET/CT images requires a thorough understanding of the basics of image formation as well as an appreciation of variations of inter-patient and intra-patient image appearance. Such variations may be caused by variations in tracer accumulation and metabolism, and, perhaps more importantly, by image artefacts related to methodological pitfalls of the two modalities. This atlas on quality control (QC) and PET/CT artefacts provides guidance on typical image distortions in clinical PET/CT usage scenarios. A number of cases are presented to provide nuclear medicine and radiology professionals with an assortment of examples of possible image distortions and errors in order to support the correct interpretation of images. About 70 typical PET and PET/CT cases, comprised of image sets and cases, have been collected in this book, and all have been catalogued and have explanations as to the causes of and solutions to each individual image problem. This atlas is intended to be used as a guide on how to take proper QC measures, on performing situation and problem analysis, and on problem prevention. This book will be especially useful to medical physicists, physicians, technologists and service engineers in the clinical field

  4. Improved image quality in abdominal CT in patients who underwent treatment for hepatocellular carcinoma with small metal implants using a raw data-based metal artifact reduction algorithm.

    Science.gov (United States)

    Sofue, Keitaro; Yoshikawa, Takeshi; Ohno, Yoshiharu; Negi, Noriyuki; Inokawa, Hiroyasu; Sugihara, Naoki; Sugimura, Kazuro

    2017-07-01

    To determine the value of a raw data-based metal artifact reduction (SEMAR) algorithm for image quality improvement in abdominal CT for patients with small metal implants. Fifty-eight patients with small metal implants (3-15 mm in size) who underwent treatment for hepatocellular carcinoma were imaged with CT. CT data were reconstructed by filtered back projection with and without SEMAR algorithm in axial and coronal planes. To evaluate metal artefact reduction, mean CT number (HU and SD) and artefact index (AI) values within the liver were calculated. Two readers independently evaluated image quality of the liver and pancreas and visualization of vasculature using a 5-point visual score. HU and AI values and image quality on images with and without SEMAR were compared using the paired Student's t-test and Wilcoxon signed rank test. Interobserver agreement was evaluated using linear-weighted κ test. Mean HU and AI on images with SEMAR was significantly lower than those without SEMAR (P small metal implants by reducing metallic artefacts. • SEMAR algorithm significantly reduces metallic artefacts from small implants in abdominal CT. • SEMAR can improve image quality of the liver in dynamic CECT. • Confidence visualization of hepatic vascular anatomies can also be improved by SEMAR.

  5. A new ICA-based fingerprint method for the automatic removal of physiological artifacts from EEG recordings

    Science.gov (United States)

    Tamburro, Gabriella; Fiedler, Patrique; Stone, David; Haueisen, Jens

    2018-01-01

    Background EEG may be affected by artefacts hindering the analysis of brain signals. Data-driven methods like independent component analysis (ICA) are successful approaches to remove artefacts from the EEG. However, the ICA-based methods developed so far are often affected by limitations, such as: the need for visual inspection of the separated independent components (subjectivity problem) and, in some cases, for the independent and simultaneous recording of the inspected artefacts to identify the artefactual independent components; a potentially heavy manipulation of the EEG signals; the use of linear classification methods; the use of simulated artefacts to validate the methods; no testing in dry electrode or high-density EEG datasets; applications limited to specific conditions and electrode layouts. Methods Our fingerprint method automatically identifies EEG ICs containing eyeblinks, eye movements, myogenic artefacts and cardiac interference by evaluating 14 temporal, spatial, spectral, and statistical features composing the IC fingerprint. Sixty-two real EEG datasets containing cued artefacts are recorded with wet and dry electrodes (128 wet and 97 dry channels). For each artefact, 10 nonlinear SVM classifiers are trained on fingerprints of expert-classified ICs. Training groups include randomly chosen wet and dry datasets decomposed in 80 ICs. The classifiers are tested on the IC-fingerprints of different datasets decomposed into 20, 50, or 80 ICs. The SVM performance is assessed in terms of accuracy, False Omission Rate (FOR), Hit Rate (HR), False Alarm Rate (FAR), and sensitivity (p). For each artefact, the quality of the artefact-free EEG reconstructed using the classification of the best SVM is assessed by visual inspection and SNR. Results The best SVM classifier for each artefact type achieved average accuracy of 1 (eyeblink), 0.98 (cardiac interference), and 0.97 (eye movement and myogenic artefact). Average classification sensitivity (p) was 1

  6. Energy consumption and stocks of energy-converting artefacts

    International Nuclear Information System (INIS)

    Bladh, Mats

    2012-01-01

    The development of total energy consumption is important in a world with limited resources. It is the result of two basic tendencies working in opposite directions: growth in number and in use (such as more cars and driving more) and improvements in energy efficiency (such as more fuel-efficient engines). Since the 1970s growth of energy consumption has slowed down in Sweden. This means that increasing supply has been counteracted by measures improving overall energy efficiency to a larger degree than before. How can long-term development in energy consumption be analysed? This paper proposes a focus on stocks of energy-converting artefacts as a tool for such analyses. In order to show the fruitfulness of this approach, historical data on cars, dwellings and lamps in Sweden are used. Results from the cases in this paper show considerable gains of efficiency in fuel consumption in private cars and heating efficiency in multi-dwelling houses. Demographic factors are important for the outcome. The approach seems to promise a way to analyse energy efficiency that captures both promoting and counteracting factors at both the micro and macro level. - Highlights: ► Growth of energy consumption slowed down in the 1970s, a break in the long-run trend. ► Balance between growth and efficiency factors changes over time and areas of use. ► Savings in heating were not taken back, while those for cars were. ► Focus on stocks of artefacts is a promising tool for analyses. ► Incremental changes within existing stocks can be as big as radical changes.

  7. Evaluation of the impact of dental artefacts on intensity-modulated radiotherapy planning for the head and neck

    International Nuclear Information System (INIS)

    Webster, Gareth J.; Rowbottom, Carl G.; Mackay, Ranald I.

    2009-01-01

    Background and purpose: High density materials create severe artefacts in the computed tomography (CT) scans used for radiotherapy dose calculations. Increased use of intensity-modulated radiotherapy (IMRT) to treat oropharyngeal cancers raises concerns over the accuracy of the resulting dose calculation. This work quantifies their impact and evaluates a simple corrective technique. Materials and methods: Fifteen oropharyngeal patients with severe artefacts were retrospectively planned with IMRT using two different CT/density look-up tables. Each plan was recalculated using a corrected CT dataset to evaluate the dose distribution delivered to the patient. Plan quality in the absence of dental artefacts was similarly assessed. A range of dosimetric and radiobiological parameters were compared pre- and post-correction. Results: Plans using a standard CT/density look-up table (density ≤1.8 g/cm 3 ) revealed inconsistent inter-patient errors, mostly within clinical acceptance, although potentially significantly reducing target coverage for individual patients. Using an extended CT/density look-up table (density ≤10.0 g/cm 3 ) greatly reduced the errors for 13/15 patients. In 2/15 patients with residual errors the CTV extended into the severely affected region and could be corrected by applying a simple manual correction. Conclusions: Use of an extended CT/density look-up table together with a simple manual bulk density correction reduces the impact of dental artefacts on head and neck IMRT planning to acceptable levels.

  8. Evaluation and reduction of magnetic resonance imaging artifacts induced by distinct plates for osseous fixation: an in vitro study @ 3T.

    Science.gov (United States)

    Rendenbach, Carsten; Schoellchen, Maximilian; Bueschel, Julie; Gauer, Tobias; Sedlacik, Jan; Kutzner, Daniel; Vallittu, Pekka K; Heiland, Max; Smeets, Ralf; Fiehler, Jens; Siemonsen, Susanne

    2018-05-02

    To analyze Magnetic Resonance Imaging (MRI) artifact induced at 3 Tesla by bioresorbable, titanium and glass fiber reinforced composite (GFRC) plates for osseous reconstruction. Fixation plates including bioresorbable polymers (Inion CPS, Inion Oy, Tampere, Finland; Rapidsorb, DePuy Synthes, Umkirch, Germany; Resorb X, Gebrueder KLS Martin GmbH, Tuttlingen, Germany), Glass fiber reinforced composite (Skulle Implants Oy, Turku, Finland) and titanium plates of varying thickness and design (DePuy Synthes, Umkirch, Germany) were embedded in agarose gel and a 3T MRI was performed using a standard protocol for head and neck imaging including T1w and T2w sequences. Additionally, different artifact reducing sequence techniques (slice encoding for metal artifact reduction (SEMAC) & ultrashort echotime (UTE)) were used and their impact on the extent of artifacts evaluated for each material. All titanium plates induced significantly more artefacts than resorbable plates in T1w and T2w sequences. Glass fiber-reinforced composites induced the least artefacts in both sequences. The total extent of artefacts increased with plate thickness and height. Plate thickness had no influence on the percentage of overestimation in all three dimensions. Titanium induced artefacts were significantly reduced by both artifact reducing sequence techniques. Polylactide, glass fiber-reinforced composite and magnesium plates produce less susceptibility artefacts in MRI compared to titanium, while the dimensions of titanium plates directly influence artifact extension. SEMAC and UTE significantly reduce metal artefacts at the expense of image resolution.

  9. Differences between state entropy and bispectral index during analysis of identical electroencephalogram signals: a comparison with two randomised anaesthetic techniques.

    Science.gov (United States)

    Pilge, Stefanie; Kreuzer, Matthias; Karatchiviev, Veliko; Kochs, Eberhard F; Malcharek, Michael; Schneider, Gerhard

    2015-05-01

    It is claimed that bispectral index (BIS) and state entropy reflect an identical clinical spectrum, the hypnotic component of anaesthesia. So far, it is not known to what extent different devices display similar index values while processing identical electroencephalogram (EEG) signals. To compare BIS and state entropy during analysis of identical EEG data. Inspection of raw EEG input to detect potential causes of erroneous index calculation. Offline re-analysis of EEG data from a randomised, single-centre controlled trial using the Entropy Module and an Aspect A-2000 monitor. Klinikum rechts der Isar, Technische Universität München, Munich. Forty adult patients undergoing elective surgery under general anaesthesia. Blocked randomisation of 20 patients per anaesthetic group (sevoflurane/remifentanil or propofol/remifentanil). Isolated forearm technique for differentiation between consciousness and unconsciousness. Prediction probability (PK) of state entropy to discriminate consciousness from unconsciousness. Correlation and agreement between state entropy and BIS from deep to light hypnosis. Analysis of raw EEG compared with index values that are in conflict with clinical examination, with frequency measures (frequency bands/Spectral Edge Frequency 95) and visual inspection for physiological EEG patterns (e.g. beta or delta arousal), pathophysiological features such as high-frequency signals (electromyogram/high-frequency EEG or eye fluttering/saccades), different types of electro-oculogram or epileptiform EEG and technical artefacts. PK of state entropy was 0.80 and of BIS 0.84; correlation coefficient of state entropy with BIS 0.78. Nine percent BIS and 14% state entropy values disagreed with clinical examination. Highest incidence of disagreement occurred after state transitions, in particular for state entropy after loss of consciousness during sevoflurane anaesthesia. EEG sequences which led to false 'conscious' index values often showed high

  10. The origin of emeralds embedded in archaeological artefacts in Slovenia

    Directory of Open Access Journals (Sweden)

    Albina Kržič

    2013-06-01

    Full Text Available Roman gold jewellery, which was excavated in Ptuj (Poetovio and consists of a necklace, earrings and a braceletwith embedded emeralds, is part of the Slovenian archaeological artefacts collections. Crystallographic characteristics,inclusions, luminous phenomena and geological characteristics were determined in order to establish theorigin of the emeralds. Chemical composition of the emeralds was determined non-destructively using the methodsof proton-induced X-rays and gamma rays (PIXE/PIGE. The results were compared with reference emeraldsfrom Habachtal in Austria and with green beryls from the Ural Mts. Literature data for emeralds from Egypt andmodern-day Afghanistan area were used to interpret the results. Specifically, these sites were known for emeraldsbeing mined for jewellery in Roman times. It was assumed that emeralds from archaeological artefacts originatedfrom Habachtal in Austria, given that this site was the nearest to the place where found. But the emeralds fromthe necklace and earrings in fact came from Egyptian deposits. The origin of emeralds from the bracelet could nothave been determined absolutely reliably due to the lack of comparative materials; they may originate from a site inmodern-day Afghanistan or from Egypt, but certainly not from the same site as the previously mentioned emeraldsin the necklace and earrings.

  11. Primary flow meter for calibrating a sniffer test leak artefact by a pressure rise method

    Science.gov (United States)

    Arai, Kenta; Yoshida, Hajime

    2014-10-01

    Sniffer tests are used to locate leaks in equipment during operation. The sensitivity of a sniffer leak detector must be calibrated against a known gas flow to atmospheric pressure generated by a sniffer test leak artefact. We have developed a primary flow meter for calibrating gas flows to atmospheric pressure through the leak artefact. The flow meter is based on a pressure rise method and two chambers are used to measure the pressure rise with small uncertainty even at atmospheric pressure. The calibration range of the flow rate is 5 × 10-7 Pa m3 s-1 to 7 × 10-4 Pa m3 s-1 to atmospheric pressure at 23.0 °C with a minimum uncertainty of 1.4% (k = 2), as well as 4 × 10-8 Pa m3 s-1 to 5 × 10-4 Pa m3 s-1 to a vacuum at 23.0 °C. The long term stability of the flow meter was determined as 0.41% by repeated measurements of the conductance of the leak artefact. In case of the flow rate into a vacuum, the flow meter was successfully linked to the international reference value of CCM.P-K12 by a lab-internal comparison.

  12. Persuasiveness, Personalization & Productive Workplace Practices with IT-Knowledge Artefacts

    DEFF Research Database (Denmark)

    Fischer, Louise Harder; Pries-Heje, Lene

    2016-01-01

    work. We see a possible way forward for improving workplace practices with IT-knowledge artefact based applications, by combining new insight of how different personality traits prefer different knowledge sharing processes with new insight on personalizing persuasive technology. We explore new research......The workplace is getting increasingly globalized, virtualized and networked. At the same time, work itself has become discrete, autonomous and complex. In a fast changing world, the individual knowledge worker and his interactions becomes the new locus of value creation. Management promote...

  13. A flint artefact (Accession No. DONMG 2016.7.1 from Lindholme, South Yorkshire

    Directory of Open Access Journals (Sweden)

    Alan Saville

    2016-09-01

    Full Text Available One of the last papers which Alan was working on when he died was a short note on a flint artefact from the surface of a gravel scrape at Lindholme in South Yorkshire. This was found during fieldwork by Robert Friend, a postgraduate student in Geography at the University of Edinburgh, working on the limits of the last glaciation in the Vale of York (Friend 2011. The results of this have been published elsewhere (Bateman et al. 2015; Friend et al. 2016, but the context of the artefact is ambivalent and Alan’s appendix on the flint was judged too archaeological and site specific for inclusion in either paper. It is a find, however, worth placing on record as one of a number of scattered surface finds of Upper Palaeolithic affinity from the region (compare with Garton et al. 2016; Grassam & Weston 2015; Harding et al. 2014.

  14. Colloids or artefacts? A TVO/SKB cooperation project in Olkiluoto, Finland

    International Nuclear Information System (INIS)

    Laaksoharju, M.; Vuorinen, U.; Snellman, M.; Helenius, J.; Allard, B.; Pettersson, C.; Hinkkanen, H.

    1993-12-01

    TVO (Teollisuuden Voima Oy, Finland) initiated a co-operative task with SKB (Swedish Nuclear Fuel and Waste Management Co.) to critically evaluate colloid sampling methods at the test site in Olkiluoto, SW Finland. Three different colloid sampling methods were compared when sampling borehole OL-KR1 at 613-618 m depth. One possible way to make a conservative in-situ colloid estimation is to omit the contribution from calcite precipitation which is considered to be the main artefact. When this is made the inorganic colloid content (size 1-1000 nm) in Olkiluoto is 184 ±177 ppb consisting of clay minerals, silica, pyrite, goethite and magnesium oxide; the concentration of organic substances are around 100 ppb. The in-situ colloid concentration seems to be low which is in good agreement with experiences from years of sampling in similar environment and depths. The exercise shows the many difficulties encountered when sampling colloids. Small error in the planning, pump rate selection, a lack of precautionary measures, artefact sensitivity of the method etc have a tendency to affect significantly the results on the measured ppb colliod level

  15. Multi-secular corrosion behaviour of low carbon steel in anoxic soils: Characterisation of corrosion system on archaeological artefacts

    International Nuclear Information System (INIS)

    Saheb, M.; Neff, D.; Dillmann, P.; Foy, E.; Saheb, M.; Dillmann, P.; Matthiesen, H.; Bellot-Gurlet, L.

    2009-01-01

    In the context of the prediction of materials behaviour used in the nuclear waste storage, the understanding of iron corrosion mechanisms in anoxic environment is of great importance. Information can be obtained using complementary analytical tools. Interactions between burial soil and archaeological artefacts are studied by performing on site soil measurements. Moreover, archaeological artefacts are studied on transverse sections using a combination of microbeam techniques. The specific interest of this project lies in the study of ferrous thick corrosion layers formed in anoxic environment. (authors)

  16. Spatial analysis of "crazy quilts", a class of potentially random aesthetic artefacts.

    Directory of Open Access Journals (Sweden)

    Gesche Westphal-Fitch

    Full Text Available Human artefacts in general are highly structured and often display ordering principles such as translational, reflectional or rotational symmetry. In contrast, human artefacts that are intended to appear random and non symmetrical are very rare. Furthermore, many studies show that humans find it extremely difficult to recognize or reproduce truly random patterns or sequences. Here, we attempt to model two-dimensional decorative spatial patterns produced by humans that show no obvious order. "Crazy quilts" represent a historically important style of quilt making that became popular in the 1870s, and lasted about 50 years. Crazy quilts are unusual because unlike most human artefacts, they are specifically intended to appear haphazard and unstructured. We evaluate the degree to which this intention was achieved by using statistical techniques of spatial point pattern analysis to compare crazy quilts with regular quilts from the same region and era and to evaluate the fit of various random distributions to these two quilt classes. We found that the two quilt categories exhibit fundamentally different spatial characteristics: The patch areas of crazy quilts derive from a continuous random distribution, while area distributions of regular quilts consist of Gaussian mixtures. These Gaussian mixtures derive from regular pattern motifs that are repeated and we suggest that such a mixture is a distinctive signature of human-made visual patterns. In contrast, the distribution found in crazy quilts is shared with many other naturally occurring spatial patterns. Centroids of patches in the two quilt classes are spaced differently and in general, crazy quilts but not regular quilts are well-fitted by a random Strauss process. These results indicate that, within the constraints of the quilt format, Victorian quilters indeed achieved their goal of generating random structures.

  17. Spatial analysis of "crazy quilts", a class of potentially random aesthetic artefacts.

    Science.gov (United States)

    Westphal-Fitch, Gesche; Fitch, W Tecumseh

    2013-01-01

    Human artefacts in general are highly structured and often display ordering principles such as translational, reflectional or rotational symmetry. In contrast, human artefacts that are intended to appear random and non symmetrical are very rare. Furthermore, many studies show that humans find it extremely difficult to recognize or reproduce truly random patterns or sequences. Here, we attempt to model two-dimensional decorative spatial patterns produced by humans that show no obvious order. "Crazy quilts" represent a historically important style of quilt making that became popular in the 1870s, and lasted about 50 years. Crazy quilts are unusual because unlike most human artefacts, they are specifically intended to appear haphazard and unstructured. We evaluate the degree to which this intention was achieved by using statistical techniques of spatial point pattern analysis to compare crazy quilts with regular quilts from the same region and era and to evaluate the fit of various random distributions to these two quilt classes. We found that the two quilt categories exhibit fundamentally different spatial characteristics: The patch areas of crazy quilts derive from a continuous random distribution, while area distributions of regular quilts consist of Gaussian mixtures. These Gaussian mixtures derive from regular pattern motifs that are repeated and we suggest that such a mixture is a distinctive signature of human-made visual patterns. In contrast, the distribution found in crazy quilts is shared with many other naturally occurring spatial patterns. Centroids of patches in the two quilt classes are spaced differently and in general, crazy quilts but not regular quilts are well-fitted by a random Strauss process. These results indicate that, within the constraints of the quilt format, Victorian quilters indeed achieved their goal of generating random structures.

  18. Algorithms that eliminate the effects of calibration artefact and trial-imposed offsets of Masimo oximeter in BOOST-NZ trial.

    Science.gov (United States)

    Zahari, Marina; Lee, Dominic Savio; Darlow, Brian Alexander

    2016-10-01

    The displayed readings of Masimo pulse oximeters used in the Benefits Of Oxygen Saturation Targeting (BOOST) II and related trials in very preterm babies were influenced by trial-imposed offsets and an artefact in the calibration software. A study was undertaken to implement new algorithms that eliminate the effects of offsets and artefact. In the BOOST-New Zealand trial, oxygen saturations were averaged and stored every 10 s up to 36 weeks' post-menstrual age. Two-hundred and fifty-seven of 340 babies enrolled in the trial had at least two weeks of stored data. Oxygen saturation distribution patterns corresponding with a +3 % or -3 % offset in the 85-95 % range were identified together with that due to the calibration artefact. Algorithms involving linear and quadratic interpolations were developed, implemented on each baby of the dataset and validated using the data of a UK preterm baby, as recorded from Masimo oximeters with the original software and a non-offset Siemens oximeter. Saturation distributions obtained were compared for both groups. There were a flat region at saturations 85-87 % and a peak at 96 % from the lower saturation target oximeters, and at 93-95 and 84 % respectively from the higher saturation target oximeters. The algorithms lowered the peaks and redistributed the accumulated frequencies to the flat regions and artefact at 87-90 %. The resulting distributions were very close to those obtained from the Siemens oximeter. The artefact and offsets of the Masimo oximeter's software had been addressed to determine the true saturation readings through the use of novel algorithms. The implementation would enable New Zealand data be included in the meta-analysis of BOOST II trials, and be used in neonatal oxygen studies.

  19. A Comparative Analysis of Techniques for PAPR Reduction of OFDM Signals

    Directory of Open Access Journals (Sweden)

    M. Janjić

    2014-06-01

    Full Text Available In this paper the problem of high Peak-to-Average Power Ratio (PAPR in Orthogonal Frequency-Division Multiplexing (OFDM signals is studied. Besides describing three techniques for PAPR reduction, SeLective Mapping (SLM, Partial Transmit Sequence (PTS and Interleaving, a detailed analysis of the performances of these techniques for various values of relevant parameters (number of phase sequences, number of interleavers, number of phase factors, number of subblocks depending on applied technique, is carried out. Simulation of these techniques is run in Matlab software. Results are presented in the form of Complementary Cumulative Distribution Function (CCDF curves for PAPR of 30000 randomly generated OFDM symbols. Simulations are performed for OFDM signals with 32 and 256 subcarriers, oversampled by a factor of 4. A detailed comparison of these techniques is made based on Matlab simulation results.

  20. Analyzing radiation absorption difference of dental substance by using Dual CT

    Science.gov (United States)

    Yu, H.; Lee, H. K.; Cho, J. H.; Yang, H. J.; Ju, Y. S.

    2015-07-01

    The purpose of this study was to evaluate the changes of noise and computer tomography (CT) number in each dental substance, by using the metal artefact reduction algorithm; we used dual CT for this study. For the study, we produced resin, titanium, gypsum, and wax that are widely used by dentists. In addition, we made nickel to increase the artefact. While making the study materials, we made sure that there is no difficulty when inserting the substances inside phantom. In order to study, we scanned before and after using the metal artefact reduction algorithm. We conducted an average analysis of CT number and noise, before and after using the metal artefact reduction algorithm. As a result, there was no difference in CT number and noise before and after using the metal artefact reduction algorithm. However, when it comes to the noise value in each substance, wax's noise value was the lowest whereas titanium's noise value was the highest, after applying the metal artefact reduction algorithm. In nickel, CT number and noise value from artefact area showed a decreased noise value when applying the metal artefact reduction algorithm. In conclusion, we assumed that we could increase the effectiveness of CT examination by applying dual energy's metal artefact reduction algorithm.

  1. Pixeanalysis of some artefacts from the first Bulgarian capital pliska in 9th-11th centuries

    International Nuclear Information System (INIS)

    Georgiev, Pavel; Ilieva, Galina; Penev, Ilia; Tzekova, Galina; Pantelica, Dan; Pantelica, Ana; Ionescu, Paul; Gugiu, Marius; Fluerasu, Daniela; Calinescu, Ionut C.; Costache, Cristian

    2014-01-01

    Proton Induced X-ray Emission (PIXE) technique has been applied to determine major, minor and trace elements in 20 metallic and glass artefacts discovered in 2012 from the archaeological site Pliska, the old capital of Bulgaria in 9th-11th centuries. PIXE analysis was performed using a 3 MeV proton beam in vacuum at the 9 MeV Van de Graaff Tandem accelerator of IFIN-HH in Bucharest-Magurele, Romania. The GUPIX (Guelph PIXE) programme was employed to determine the quantities of around 30 elements (Z ≥ 14) in the investigated samples. The obtained results were compared with literature data for the medieval epoch in Bulgaria. Key words: PIXE, elemental content, artefacts, metal, glass, Pliska, Bulgaria

  2. Comparison of dimensionality reduction techniques for the fault diagnosis of mono block centrifugal pump using vibration signals

    Directory of Open Access Journals (Sweden)

    N.R. Sakthivel

    2014-03-01

    Full Text Available Bearing fault, Impeller fault, seal fault and cavitation are the main causes of breakdown in a mono block centrifugal pump and hence, the detection and diagnosis of these mechanical faults in a mono block centrifugal pump is very crucial for its reliable operation. Based on a continuous acquisition of signals with a data acquisition system, it is possible to classify the faults. This is achieved by the extraction of features from the measured data and employing data mining approaches to explore the structural information hidden in the signals acquired. In the present study, statistical features derived from the vibration data are used as the features. In order to increase the robustness of the classifier and to reduce the data processing load, dimensionality reduction is necessary. In this paper dimensionality reduction is performed using traditional dimensionality reduction techniques and nonlinear dimensionality reduction techniques. The effectiveness of each dimensionality reduction technique is also verified using visual analysis. The reduced feature set is then classified using a decision tree. The results obtained are compared with those generated by classifiers such as Naïve Bayes, Bayes Net and kNN. The effort is to bring out the better dimensionality reduction technique–classifier combination.

  3. Image quality and artefact generation post-cerebral aneurysm clipping using a 64-row multislice computer tomography angiography (MSCTA) technology: A retrospective study and review of the literature.

    Science.gov (United States)

    Zachenhofer, Iris; Cejna, Manfred; Schuster, Antonius; Donat, Markus; Roessler, Karl

    2010-06-01

    Computed tomography angiography (CTA) is a time and cost saving investigation for postoperative evaluation of clipped cerebral aneurysm patients. A retrospective study was conducted to analyse image quality and artefact generation due to implanted aneurysm clips using a new technology. MSCTA was performed pre- and postoperatively using a Philips Brilliance 64-detector-row CT scanner. Altogether, 32 clipping sites were analysed in 27 patients (11 female and 16 male, mean ages 52a, from 24 to 72 years). Clip number per aneurysm was 2.3 mean (from 1 to 4), 54 clips were made of titanium alloy and 5 of cobalt alloy. Altogether, image quality was rated 1.8 mean, using a scale from 1 (very good) to 5 (unserviceable) and clip artefacts were rated 2.4 mean, using a 5 point rating scale (1 no artefacts, 5 unserviceable due to artefacts). A significant loss of image quality and rise of artefacts was found when using cobalt alloy clips (1.4 versus 4.2 and 2.1 versus 4.0). In 72% of all investigations, an excellent image quality was found. Excluding the cobalt clip group, 85% of scans showed excellent image quality. Artefacts were absent or minimal (grade 1 or 2) in 69% of all investigations and in 81% in the pure titanium clip group. In 64-row MSCTA of good image quality with low artefacts, it was possible to detect small aneurysm remnants of 2mm size in individual patients. By using titanium alloy clips, in our study up to 85% of postoperative CTA images were of excellent quality with absent or minimal artefacts in 81% and seem adequate to detect small aneurysm remnants. Copyright 2010 Elsevier B.V. All rights reserved.

  4. Lesion concordance, image quality and artefacts in PET/CT. Results of a multicenter study

    International Nuclear Information System (INIS)

    Stergar, H.; Bockisch, A.; Krause, B.J.; Eschmann, S.M.; Juergens, K.U.; Kuehl, H.; Pfannenberg, A.C.; Stollfuss, J.; Weckesser, M.

    2010-01-01

    This study had three major objectives: (1.) to record the number of concordant (both in PET and CT) pathological lesions in different body regions/organs, (2.) to evaluate the image quality and (3.) to determine both, the quantity and the quality of artefacts in whole body FDG PET/CT scans. Routine whole body scans of 353 patients referred to FDG-PET/CT exams at 4 university hospitals were employed. All potentially malignant lesions in 13 different body regions/organs were classified as either concordant or suspicious in FDG-PET or CT only. In the latter case the diagnostic relevance of this disparity was judged. The image quality in PET and CT was rated as a whole and separately in 5 different body regions. Furthermore we investigated the frequency and site of artefacts caused by metal implants and oral or intravenous contrast media as well as the subjective co-registration quality (in 4 body regions) and the diagnostic impact of such artefacts or misalignment. In addition, the readers rated the diagnostic gain of adding the information from the other tomographic method. In total 1941 lesions (5.5 per patient) were identified, 1094 (56%) out of which were concordant. 602 (71%) out of the 847 remaining lesions were detected only with CT, 245 (29%) were only PET-positive. As expected, CT particularly depicted the majority of lesions in the lungs and abdominal organs. However, the diagnostic relevance was greater with PET-only positive lesions. Most of the PET/CT scans were performed with full diagnostic CT including administration of oral and intravenous contast media (> 80%). The image quality in PET and CT was rated excellent. Artefacts occurred in more than 60% of the scans and were mainly due to (dental) metal implants and contrast agent. Nevertheless there was almost no impact on diagnostic confidence if reading of the non attenuation corrected PET was included. The co-registration quality in general was also rated as excellent. Misalignment mostly occurred due

  5. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants. A phantom study

    International Nuclear Information System (INIS)

    Harnish, R.; Lang, T.F.; Prevrhal, S.; Alavi, A.; Zaidi, H.

    2014-01-01

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of 18 F-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom hip prosthesis phantom with a lesion-sized cavity filled with 0.2 ml 18 F-FDG solution having an activity of 3.367 MBq adjacent to a prosthesis bore was imaged twice with a chrome-cobalt steel hip prosthesis and a plastic replica, respectively. Scanning was performed on a clinical hybrid PET/CT system equipped with an additional external 137 Cs transmission source. PET emission images were reconstructed from both phantom configurations with CT-based attenuation correction (CTAC) and with CT-based attenuation correction using MAR (MARCTAC). To compare results with the attenuation-correction method extant prior to the advent of PET/CT, we also carried out attenuation correction with 137 Cs transmission-based attenuation correction (TXAC). CTAC and MARCTAC images were scaled to attenuation coefficients at 511 keV using a trilinear function that mapped the highest CT values to the prosthesis alloy attenuation coefficient. Accuracy and spatial distribution of the lesion activity was compared between the three reconstruction schemes. Compared to the reference activity of 3.37 MBq, the estimated activity quantified from the PET image corrected by TXAC was 3.41 MBq. The activity estimated from PET images corrected by MARCTAC was similar in accuracy at 3.32 MBq. CTAC corrected PET images resulted in nearly 40% overestimation of lesion activity at 4.70 MBq. Comparison of PET images obtained with the plastic and metal prostheses in place showed that CTAC resulted in a marked distortion of the 18 F-FDG distribution within the lesion, whereas application of MARCTAC and TXAC resulted in lesion distributions similar to those observed with the plastic replica. (author)

  6. The development of equipment for the technical assessment of respiratory motion induced artefacts in MRI

    International Nuclear Information System (INIS)

    Jackson, P.C.; Davies, S.C.; Zananiri, F.V.; Follett, D.H.; Halliwell, M.; Wells, P.N.T.; Bean, J.P.

    1993-01-01

    A device and technique to study the effects of respiratory motion on the quality of magnetic resonance images is proposed. The construction of the device enables a variety of test objects to be mounted and used in the evaluation of imaging parameters that may be affected by motion. The equipment is constructed of cast acrylic and the movement is actuated and controlled pneumatically thus ensuring that there are no interactions with the magnetic field and radiofrequency detection system to cause further image artefacts. Separate studies have been performed, using ultrasound, to assess the degree and rate of movement of organs owing to respiration in order to derive the motion parameters for the apparatus. Preliminary results indicate that the technique produces motion induced artefacts simulating those which are the result of the effects of respiration. (author)

  7. The characterisation of Melanesian obsidian sources and artefacts using the proton induced gamma-ray emission (PIGME) technique

    International Nuclear Information System (INIS)

    Bird, J.R.; Ambrose, W.R.; Russell, L.H.; Scott, M.D.

    1981-09-01

    Proton induced gamma-ray emission (PIGME) has been used to determine F, Na and Al concentrations in obsidian from known locations in Melanesia and to relate artefacts from this region to such sources. The PIGME technique is a fast, non-destructive, and accurate method for determining these three elements with essentially no special sample preparation. The measuring technique is described and results are listed for sources, chiefly in the Papua New Guinea region. Their classification is discussed in terms of groups which are distinguishable by the PIGME method. Over 700 artefact results are listed; these show the occurrence of an additional group that is not geographically identified

  8. Sci—Fri PM: Dosimetry—01: Radiation-induced refraction artefacts in the optical CT readout of polymer gel dosimeters

    International Nuclear Information System (INIS)

    Campbell, Warren G; Jirasek, Andrew; Wells, Derek M

    2014-01-01

    Polymer gel dosimeters (PGDs) are a desirable tool for the verification of advanced radiotherapy treatments. Fully 3D, deformable, and tissue-equivalent, the PGD polymerizes wherever it absorbs dose. To measure the dose absorbed by a PGD, optical computed tomography (CT) can be used to evaluate, in full 3D, the opacity distribution that coincides with polymerization. In addition to an increase in opacity with dose, an increase in refractive index (RI) is also known to occur in irradiated polymer gels. The increase in RI is slight and was previously assumed insignificant. This work reveals the effects that radiation-induced RI changes can have on the optical CT readout of PGDs. A fan-beam optical CT scanner was used to image a cylindrical PGD irradiated by a pair of 3×3 cm 2 , 6 MV photon beams in an orthogonal arrangement. Investigative scans were performed to evaluate refraction errors occurring: i) within the plane, and ii) out of the plane of the fan-beam. In-plane refraction was shown to cause distinct streaking artefacts along dose gradients (i.e. RI gradients) due to higher intensity rays being refracted into more opaque regions. Out-of-plane refraction was shown to produce severe, widespread artefacts due to rays missing the detector array. An iterative Savitzky-Golay filtering technique was developed to reduce both types of artefacts by specifically targeting structured errors in sinogram space. Results introduce a new category of imaging artefacts to be aware of when using optical CT for PGD readout

  9. Receiver-based recovery of clipped ofdm signals for papr reduction: A bayesian approach

    KAUST Repository

    Ali, Anum

    2014-01-01

    Clipping is one of the simplest peak-to-average power ratio reduction schemes for orthogonal frequency division multiplexing (OFDM). Deliberately clipping the transmission signal degrades system performance, and clipping mitigation is required at the receiver for information restoration. In this paper, we acknowledge the sparse nature of the clipping signal and propose a low-complexity Bayesian clipping estimation scheme. The proposed scheme utilizes a priori information about the sparsity rate and noise variance for enhanced recovery. At the same time, the proposed scheme is robust against inaccurate estimates of the clipping signal statistics. The undistorted phase property of the clipped signal, as well as the clipping likelihood, is utilized for enhanced reconstruction. Furthermore, motivated by the nature of modern OFDM-based communication systems, we extend our clipping reconstruction approach to multiple antenna receivers and multi-user OFDM.We also address the problem of channel estimation from pilots contaminated by the clipping distortion. Numerical findings are presented that depict favorable results for the proposed scheme compared to the established sparse reconstruction schemes.

  10. Introduction. Leave no stone unturned: Perspectives on ground stone artefact research

    OpenAIRE

    Danny Rosenberg; Yorke Rowan; Tatjana Gluhak

    2016-01-01

    Ground stone tools served in many physical and social contexts through millennia, reflecting a wide variety of functions. Although ground stone tool studies were neglected for much of early archaeology, the last few decades witnessed a notable international uptick in the way archaeologists confront this multifaceted topic. Today, with the advance of archaeology as a discipline, research into ground stone artefacts is moving into a new phase that integrates high resolution documentation with n...

  11. Spatial Analysis of “Crazy Quilts”, a Class of Potentially Random Aesthetic Artefacts

    Science.gov (United States)

    Westphal-Fitch, Gesche; Fitch, W. Tecumseh

    2013-01-01

    Human artefacts in general are highly structured and often display ordering principles such as translational, reflectional or rotational symmetry. In contrast, human artefacts that are intended to appear random and non symmetrical are very rare. Furthermore, many studies show that humans find it extremely difficult to recognize or reproduce truly random patterns or sequences. Here, we attempt to model two-dimensional decorative spatial patterns produced by humans that show no obvious order. “Crazy quilts” represent a historically important style of quilt making that became popular in the 1870s, and lasted about 50 years. Crazy quilts are unusual because unlike most human artefacts, they are specifically intended to appear haphazard and unstructured. We evaluate the degree to which this intention was achieved by using statistical techniques of spatial point pattern analysis to compare crazy quilts with regular quilts from the same region and era and to evaluate the fit of various random distributions to these two quilt classes. We found that the two quilt categories exhibit fundamentally different spatial characteristics: The patch areas of crazy quilts derive from a continuous random distribution, while area distributions of regular quilts consist of Gaussian mixtures. These Gaussian mixtures derive from regular pattern motifs that are repeated and we suggest that such a mixture is a distinctive signature of human-made visual patterns. In contrast, the distribution found in crazy quilts is shared with many other naturally occurring spatial patterns. Centroids of patches in the two quilt classes are spaced differently and in general, crazy quilts but not regular quilts are well-fitted by a random Strauss process. These results indicate that, within the constraints of the quilt format, Victorian quilters indeed achieved their goal of generating random structures. PMID:24066095

  12. The fourth dimension of tool use: temporally enduring artefacts aid primates learning to use tools.

    Science.gov (United States)

    Fragaszy, D M; Biro, D; Eshchar, Y; Humle, T; Izar, P; Resende, B; Visalberghi, E

    2013-11-19

    All investigated cases of habitual tool use in wild chimpanzees and capuchin monkeys include youngsters encountering durable artefacts, most often in a supportive social context. We propose that enduring artefacts associated with tool use, such as previously used tools, partly processed food items and residual material from previous activity, aid non-human primates to learn to use tools, and to develop expertise in their use, thus contributing to traditional technologies in non-humans. Therefore, social contributions to tool use can be considered as situated in the three dimensions of Euclidean space, and in the fourth dimension of time. This notion expands the contribution of social context to learning a skill beyond the immediate presence of a model nearby. We provide examples supporting this hypothesis from wild bearded capuchin monkeys and chimpanzees, and suggest avenues for future research.

  13. From Governing through Data to Governmentality through Data: Artefacts, Strategies and the Digital Turn

    Science.gov (United States)

    Souto-Otero, Manuel; Beneito-Montagut, Roser

    2016-01-01

    The article argues that current discussions about governance through data in education can be fruitfully extended through: (1) the establishment of connections with wider debates about the role of commensuration processes and governmentality in the recreation of education systems; (2) greater emphasis on the "artefacts" through which…

  14. Distinguishing transient signals and instrumental disturbances in semi-coherent searches for continuous gravitational waves with line-robust statistics

    International Nuclear Information System (INIS)

    Keitel, David

    2016-01-01

    Non-axisymmetries in rotating neutron stars emit quasi-monochromatic gravitational waves. These long-duration ‘continuous wave’ signals are among the main search targets of ground-based interferometric detectors. However, standard detection methods are susceptible to false alarms from instrumental artefacts that resemble a continuous-wave signal. Past work [Keitel, Prix, Papa, Leaci and Siddiqi 2014, Phys. Rev. D 89 064023] showed that a Bayesian approach, based on an explicit model of persistent single-detector disturbances, improves robustness against such artefacts. Since many strong outliers in semi-coherent searches of LIGO data are caused by transient disturbances that last only a few hours or days, I describe in a recent paper [Keitel D 2015, LIGO-P1500159] how to extend this approach to cover transient disturbances, and demonstrate increased sensitivity in realistic simulated data. Additionally, neutron stars could emit transient signals which, for a limited time, also follow the continuous-wave signal model. As a pragmatic alternative to specialized transient searches, I demonstrate how to make standard semi-coherent continuous-wave searches more sensitive to transient signals. Focusing on the time-scale of a single segment in the semi-coherent search, Bayesian model selection yields a simple detection statistic without a significant increase in computational cost. This proceedings contribution gives a brief overview of both works. (paper)

  15. Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review

    International Nuclear Information System (INIS)

    Woodfield, Julie; Kealey, Susan

    2015-01-01

    Attaining paediatric brain images of diagnostic quality can be difficult because of young age or neurological impairment. The use of anaesthesia to reduce movement in MRI increases clinical risk and cost, while CT, though faster, exposes children to potentially harmful ionising radiation. MRI acquisition techniques that aim to decrease movement artefact may allow diagnostic paediatric brain imaging without sedation or anaesthesia. We conducted a systematic review to establish the evidence base for ultra-fast sequences and sequences using oversampling of k-space in paediatric brain MR imaging. Techniques were assessed for imaging time, occurrence of movement artefact, the need for sedation, and either image quality or diagnostic accuracy. We identified 24 relevant studies. We found that ultra-fast techniques had shorter imaging acquisition times compared to standard MRI. Techniques using oversampling of k-space required equal or longer imaging times than standard MRI. Both ultra-fast sequences and those using oversampling of k-space reduced movement artefact compared with standard MRI in unsedated children. Assessment of overall diagnostic accuracy was difficult because of the heterogeneous patient populations, imaging indications, and reporting methods of the studies. In children with shunt-treated hydrocephalus there is evidence that ultra-fast MRI is sufficient for the assessment of ventricular size. (orig.)

  16. Magnetic resonance imaging acquisition techniques intended to decrease movement artefact in paediatric brain imaging: a systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Woodfield, Julie [University of Edinburgh, Child Life and Health, Edinburgh (United Kingdom); Kealey, Susan [Western General Hospital, Department of Neuroradiology, Edinburgh (United Kingdom)

    2015-08-15

    Attaining paediatric brain images of diagnostic quality can be difficult because of young age or neurological impairment. The use of anaesthesia to reduce movement in MRI increases clinical risk and cost, while CT, though faster, exposes children to potentially harmful ionising radiation. MRI acquisition techniques that aim to decrease movement artefact may allow diagnostic paediatric brain imaging without sedation or anaesthesia. We conducted a systematic review to establish the evidence base for ultra-fast sequences and sequences using oversampling of k-space in paediatric brain MR imaging. Techniques were assessed for imaging time, occurrence of movement artefact, the need for sedation, and either image quality or diagnostic accuracy. We identified 24 relevant studies. We found that ultra-fast techniques had shorter imaging acquisition times compared to standard MRI. Techniques using oversampling of k-space required equal or longer imaging times than standard MRI. Both ultra-fast sequences and those using oversampling of k-space reduced movement artefact compared with standard MRI in unsedated children. Assessment of overall diagnostic accuracy was difficult because of the heterogeneous patient populations, imaging indications, and reporting methods of the studies. In children with shunt-treated hydrocephalus there is evidence that ultra-fast MRI is sufficient for the assessment of ventricular size. (orig.)

  17. Persistent Artefacts in an Online Classroom: The Value of a Dynamic Learning Archive

    Science.gov (United States)

    Berry, Stuart C.

    2016-01-01

    This paper summarizes a multi-year research project that examines the use and value of visible and persistent artefacts within an online learning environment. This study is framed within elements of a business management theory. Changes to an online learning environment are documented as well as an examination of the impact of these changes on the…

  18. The Mediation of Teaching and Learning Processes through "Identity Artefacts." A Vygotskian Perspective

    Science.gov (United States)

    Subero, David; Llopart, Mariona; Siqués, Carina; Esteban-Guitart, Moises

    2018-01-01

    The aim of this paper is to address the teaching and learning processes in schools from a Vygotskian perspective based on the notion of "identity artefacts" (IAs) which, for our purposes, consist of documents created by the learners about themselves, in which they try to capture all the things that make sense and are meaningful to them…

  19. SU-E-J-158: Audiovisual Biofeedback Reduces Image Artefacts in 4DCT: A Digital Phantom Study

    Energy Technology Data Exchange (ETDEWEB)

    Pollock, S; Kipritidis, J; Lee, D; Keall, P [University of Sydney, Sydney (Australia); Bernatowicz, K [Paul Scherrer Institute, Psi, Aargau (Switzerland)

    2015-06-15

    Purpose: Irregular breathing motion has a deleterious impact on 4DCT image quality. The breathing guidance system: audiovisual biofeedback (AVB) is designed to improve breathing regularity, however, its impact on 4DCT image quality has yet to be quantified. The purpose of this study was to quantify the impact of AVB on thoracic 4DCT image quality by utilizing the digital eXtended Cardiac Torso (XCAT) phantom driven by lung tumor motion patterns. Methods: 2D tumor motion obtained from 4 lung cancer patients under two breathing conditions (i) without breathing guidance (free breathing), and (ii) with guidance (AVB). There were two breathing sessions, yielding 8 tumor motion traces. This tumor motion was synchronized with the XCAT phantom to simulate 4DCT acquisitions under two acquisition modes: (1) cine mode, and (2) prospective respiratory-gated mode. Motion regularity was quantified by the root mean square error (RMSE) of displacement. The number of artefacts was visually assessed for each 4DCT and summed up for each breathing condition. Inter-session anatomic reproducibility was quantified by the mean absolute difference (MAD) between the Session 1 4DCT and Session 2 4DCT. Results: AVB improved tumor motion regularity by 30%. In cine mode, the number of artefacts was reduced from 61 in free breathing to 40 with AVB, in addition to AVB reducing the MAD by 34%. In gated mode, the number of artefacts was reduced from 63 in free breathing to 51 with AVB, in addition to AVB reducing the MAD by 23%. Conclusion: This was the first study to compare the impact of breathing guidance on 4DCT image quality compared to free breathing, with AVB reducing the amount of artefacts present in 4DCT images in addition to improving inter-session anatomic reproducibility. Results thus far suggest that breathing guidance interventions could have implications for improving radiotherapy treatment planning and interfraction reproducibility.

  20. SU-E-J-158: Audiovisual Biofeedback Reduces Image Artefacts in 4DCT: A Digital Phantom Study

    International Nuclear Information System (INIS)

    Pollock, S; Kipritidis, J; Lee, D; Keall, P; Bernatowicz, K

    2015-01-01

    Purpose: Irregular breathing motion has a deleterious impact on 4DCT image quality. The breathing guidance system: audiovisual biofeedback (AVB) is designed to improve breathing regularity, however, its impact on 4DCT image quality has yet to be quantified. The purpose of this study was to quantify the impact of AVB on thoracic 4DCT image quality by utilizing the digital eXtended Cardiac Torso (XCAT) phantom driven by lung tumor motion patterns. Methods: 2D tumor motion obtained from 4 lung cancer patients under two breathing conditions (i) without breathing guidance (free breathing), and (ii) with guidance (AVB). There were two breathing sessions, yielding 8 tumor motion traces. This tumor motion was synchronized with the XCAT phantom to simulate 4DCT acquisitions under two acquisition modes: (1) cine mode, and (2) prospective respiratory-gated mode. Motion regularity was quantified by the root mean square error (RMSE) of displacement. The number of artefacts was visually assessed for each 4DCT and summed up for each breathing condition. Inter-session anatomic reproducibility was quantified by the mean absolute difference (MAD) between the Session 1 4DCT and Session 2 4DCT. Results: AVB improved tumor motion regularity by 30%. In cine mode, the number of artefacts was reduced from 61 in free breathing to 40 with AVB, in addition to AVB reducing the MAD by 34%. In gated mode, the number of artefacts was reduced from 63 in free breathing to 51 with AVB, in addition to AVB reducing the MAD by 23%. Conclusion: This was the first study to compare the impact of breathing guidance on 4DCT image quality compared to free breathing, with AVB reducing the amount of artefacts present in 4DCT images in addition to improving inter-session anatomic reproducibility. Results thus far suggest that breathing guidance interventions could have implications for improving radiotherapy treatment planning and interfraction reproducibility

  1. Plasma cleaning and analysis of archeological artefacts from Sipan

    Energy Technology Data Exchange (ETDEWEB)

    Saettone, E A O [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, CEP 05508-900 (Brazil); Matta, J A S da [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, CEP 05508-900 (Brazil); Alva, W [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, CEP 05508-900 (Brazil); Chubaci, J F O [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, CEP 05508-900 (Brazil); Fantini, M C A [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, CEP 05508-900 (Brazil); Galvao, R M O [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, CEP 05508-900 (Brazil); Kiyohara, P [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, CEP 05508-900 (Brazil); Tabacniks, M H [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo, CEP 05508-900 (Brazil)

    2003-04-07

    A novel procedure using plasma sputtering in an electron-cyclotron-resonance device has been applied to clean archeological MOCHE artefacts, unearthed at the Royal Tombs of Sipan. After successful cleaning, the pieces were analysed by a variety of complementary techniques, namely proton-induced x-ray emission, Rutherford backscattering spectroscopy, x-ray diffraction, electron microscopy, and inductively coupled plasma mass spectroscopy. With these techniques, it has been possible to not only determine the profiles of the gold and silver surface layers, but also to detect elements that may be relevant to explain the gilding techniques skillfully developed by the metal smiths of the MOCHE culture.

  2. Feasibility of clinical magnetoencephalography (MEG) functional mapping in the presence of dental artefacts.

    Science.gov (United States)

    Hillebrand, A; Fazio, P; de Munck, J C; van Dijk, B W

    2013-01-01

    To evaluate the viability of MEG source reconstruction in the presence of large interference due to orthodontic material. We recorded the magnetic fields following a simple hand movement and following electrical stimulation of the median nerve (somatosensory evoked field -SEF). These two tasks were performed twice, once with and once without artificial dental artefacts. Temporal Signal Space Separation (tSSS) was applied to spatially filter the data and source reconstruction was performed according to standard procedures for pre-surgical mapping of eloquent cortex, applying dipole fitting to the SEF data and beamforming to the hand movement data. Comparing the data with braces to the data without braces, the observed distances between the activations following hand movement in the two conditions were on average 6.4 and 4.5 mm for the left and right hand, respectively, whereas the dipole localisation errors for the SEF were 4.1 and 5.4 mm, respectively. Without tSSS it was generally not possible to obtain reliable dipole fit or beamforming results when wearing braces. We confirm that tSSS is a required and effective pre-processing step for data recorded with the Elekta-MEG system. Moreover, we have shown that even the presence of large interference from orthodontic material does not significantly alter the results from dipole localisation or beamformer analysis, provided the data are spatially filtered by tSSS. State-of-the-art signal processing techniques enable the use of MEG for pre-surgical evaluation in a much larger clinical population than previously thought possible. Copyright © 2012 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  3. Corrosion of archaeological iron artefacts compared to modern iron at the waterlogged site Nydam, Denmark

    DEFF Research Database (Denmark)

    Matthiesen, Henning; Hilbert, Lisbeth Rischel; Gregory, David

    2004-01-01

    focuses solely on the iron objects. A three-pronged approach has been used in the studies in Nydam: Studies of the excavated artefacts, including the compositon of corrosion products and a mapping of their exact state of preservation. 2) Use of modern iron samples placed in the soil for studies of weight......Since 1859 several archaeological excavations have been carried out in Nydam, Denmark revealing a wealth of military equipment sacrificed in the period 200 - 500 AD. During the 1990's more than 16000 artefacts of mainly wood and iron were excavated within an area of only 600 m2. Due to the volume...... loss, corrosion potential, electrochemical impedance spectroscopy and electrical resistivity. 3) Measurements of environmental parameter such as water level, redox potential, oxygen concentration, soil pH, and the concentration of a range of dissolved species in the pore water. This presentation shows...

  4. Electrocardiographic artefacts mimicking atrial tachycardia resulted in unnecessary diagnostic and therapeutic measures

    OpenAIRE

    Y-Hassan, Shams; Sylv?n, Christer

    2013-01-01

    Electrocardiographic (ECG) artefacts may closely simulate both supraventricular and ventricular tachycardias. We describe a case initially diagnosed as rapid atrial fibrillation, based on 12-lead surface ECG (especially the limb leads) and monitor tracing. The arrhythmia was resistant to beta blockers. Because of the at times apparently regular rhythm, an esophageal ECG recording was performed, and adenosine was administered. When the presumed atrial fibrillation terminated after sodium pento...

  5. Semi-automated identification of artefact and noise signals in MEG sensors

    International Nuclear Information System (INIS)

    Rettich, E.

    2006-09-01

    Magnetic encephalography (MEG) is a noninvasive method of measuring cerebral activity. It is based on the registration of magnetic fields that are induced by synaptic ion currents as the brain processes information. These magnetic fields are of a very small magnitude, ranging from a few femto Tesla (1 fT = 10 15 T) to several thousand fT (1 pT). This is equivalent to a ten thousandth to a billionth of the Earth's magnetic field. When applied with a time resolution in the range of milliseconds this technique permits research on time-critical neurophysiological processes. A meaningful analysis of MEG data presupposes that signals have been measured at low noise levels. This in turn requires magnetic shielding, normally in the form of a shielded cabin, and low-noise detectors. Data input from high-noise channels impairs the result of the measurement, possibly rendering it useless. To prevent this it is necessary to identify high-noise channels and remove them from the measurement data. At Juelich Research Center, like at most MEG laboratories, this is done by visual inspection. However, being dependent on the individual observer, this method does not yield objective results. Furthermore, visual inspection presupposes a high degree of experience and is time-consuming. This situation could be significantly improved by automated identification of high-noise channels. The purpose of the present study was to develop an algorithm that analyses measurement signals in a given time and frequency interval on the basis of statistical traits. Using a suitably designed user interface this permits searching MEG data for high-noise channel data below or above statistical threshold values on the basis of predetermined decision criteria. The identified high-noise channels are then output in a selection list, and the measurement data and results of the statistical analysis are displayed. This information enables the user to make changes and decide which high-noise channels to extract

  6. X-ray fluorescence microscopy artefacts in elemental maps of topologically complex samples: Analytical observations, simulation and a map correction method

    Science.gov (United States)

    Billè, Fulvio; Kourousias, George; Luchinat, Enrico; Kiskinova, Maya; Gianoncelli, Alessandra

    2016-08-01

    XRF spectroscopy is among the most widely used non-destructive techniques for elemental analysis. Despite the known angular dependence of X-ray fluorescence (XRF), topological artefacts remain an unresolved issue when using X-ray micro- or nano-probes. In this work we investigate the origin of the artefacts in XRF imaging of topologically complex samples, which are unresolved problems in studies of organic matter due to the limited travel distances of low energy XRF emission from the light elements. In particular we mapped Human Embryonic Kidney (HEK293T) cells. The exemplary results with biological samples, obtained with a soft X-ray scanning microscope installed at a synchrotron facility were used for testing a mathematical model based on detector response simulations, and for proposing an artefact correction method based on directional derivatives. Despite the peculiar and specific application, the methodology can be easily extended to hard X-rays and to set-ups with multi-array detector systems when the dimensions of surface reliefs are in the order of the probing beam size.

  7. Calibration artefacts in radio interferometry - III. Phase-only calibration and primary beam correction

    Science.gov (United States)

    Grobler, T. L.; Stewart, A. J.; Wijnholds, S. J.; Kenyon, J. S.; Smirnov, O. M.

    2016-09-01

    This is the third installment in a series of papers in which we investigate calibration artefacts. Calibration artefacts (also known as ghosts or spurious sources) are created when we calibrate with an incomplete model. In the first two papers of this series, we developed a mathematical framework which enabled us to study the ghosting mechanism itself. An interesting concomitant of the second paper was that ghosts appear in symmetrical pairs. This could possibly account for spurious symmetrization. Spurious symmetrization refers to the appearance of a spurious source (the antighost) symmetrically opposite an unmodelled source around a modelled source. The analysis in the first two papers indicates that the antighost is usually very faint, in particular, when a large number of antennas are used. This suggests that spurious symmetrization will mainly occur at an almost undetectable flux level. In this paper, we show that phase-only calibration produces an antighost that is N-times (where N denotes the number of antennas in the array) as bright as the one produced by phase and amplitude calibration and that this already bright ghost can be further amplified by the primary beam correction.

  8. Computed tomography by reconstruction. Brain CT scanning. I. Basic physics, equipment, normal aspects, artefacts

    International Nuclear Information System (INIS)

    Chiras, J.; Palmieri, P.; Saudinos, J.; Salamon, G.

    1980-01-01

    The authors describe the physical basis, apparatus, normal images, and artefacts of computed tomography by reconstruction. Radio-anatomical sections enable clear comprehension of the computed tomography images. Other methods using computer reconstruction are outlined: tomography by Compton effect, tomography by positrons, tomography by gamma emission, tomography by protons, tomography by nuclear magnetic resonance [fr

  9. In Vitro Validation of an Artefact Suppression Algorithm in X-Ray Phase-Contrast Computed Tomography.

    Science.gov (United States)

    Sunaguchi, Naoki; Yuasa, Tetsuya; Hirano, Shin-Ichi; Gupta, Rajiv; Ando, Masami

    2015-01-01

    X-ray phase-contrast tomography can significantly increase the contrast-resolution of conventional attenuation-contrast imaging, especially for soft-tissue structures that have very similar attenuation. Just as in attenuation-based tomography, phase contrast tomography requires a linear dependence of aggregate beam direction on the incremental direction alteration caused by individual voxels along the path of the X-ray beam. Dense objects such as calcifications in biological specimens violate this condition. There are extensive beam deflection artefacts in the vicinity of such structures because they result in large distortion of wave front due to the large difference of refractive index; for such large changes in beam direction, the transmittance of the silicon analyzer crystal saturates and is no longer linearly dependent on the angle of refraction. This paper describes a method by which these effects can be overcome and excellent soft-tissue contrast of phase tomography can be preserved in the vicinity of such artefact-producing structures.

  10. Minimally destructive DNA extraction from archaeological artefacts made from whale baleen

    DEFF Research Database (Denmark)

    Sinding, Mikkel Holger Strander; Gilbert, Tom; Grønnow, Bjarne

    2012-01-01

    Here we demonstrate the successful extraction and amplification of target species DNA from artefacts made of whale baleen collected from excavations of past palaeo-Eskimo and Inuit cultures in Greenland. DNA was successfully extracted and amplified from a single baleen bristle of 1.5 cm length...... genetic studies. We conclude that genetic investigation of historical baleen collections can contribute to our knowledge of the prehistoric population genetics of baleen whales, for example by quantifying the impact of modern whaling on the genetic diversity of bowhead whales....

  11. Laryngeal mask airway (LMA) artefact resulting in MRI misdiagnosis

    International Nuclear Information System (INIS)

    Schieble, Thomas; Patel, Anuradha; Davidson, Melissa

    2008-01-01

    We report a 7-year-old child who underwent brain MRI for a known seizure disorder. The technique used for general anesthesia included inhalation induction followed by placement of a laryngeal mask airway (LMA) for airway maintenance. Because the reviewing radiologist was unfamiliar with the use of an LMA during anesthesia, and because the attending anesthesiologist did not communicate his technique to the radiologist, an MRI misdiagnosis was reported because of artefact created by the in situ LMA. As a result of this misdiagnosis the child was subjected to unnecessary subsequent testing to rule out a reported anatomic abnormality induced by the LMA. Our case illustrates the need for coordination of patient care among hospital services. (orig.)

  12. Laryngeal mask airway (LMA) artefact resulting in MRI misdiagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Schieble, Thomas [University of Medicine and Dentistry of New Jersey, Department of Anesthesiology, New Jersey Medical School, Newark, NJ (United States); Maimonides Medical Center, Department of Anesthesiology, Brooklyn, NY (United States); Patel, Anuradha; Davidson, Melissa [University of Medicine and Dentistry of New Jersey, Department of Anesthesiology, New Jersey Medical School, Newark, NJ (United States)

    2008-03-15

    We report a 7-year-old child who underwent brain MRI for a known seizure disorder. The technique used for general anesthesia included inhalation induction followed by placement of a laryngeal mask airway (LMA) for airway maintenance. Because the reviewing radiologist was unfamiliar with the use of an LMA during anesthesia, and because the attending anesthesiologist did not communicate his technique to the radiologist, an MRI misdiagnosis was reported because of artefact created by the in situ LMA. As a result of this misdiagnosis the child was subjected to unnecessary subsequent testing to rule out a reported anatomic abnormality induced by the LMA. Our case illustrates the need for coordination of patient care among hospital services. (orig.)

  13. Automated correction of spin-history related motion artefacts in fMRI : Simulated and phantom data

    NARCIS (Netherlands)

    Muresan, L; Renken, R.; Roerdink, J.B.T.M.; Duifhuis, H.

    This paper concerns the problem of correcting spin-history artefacts in fMRI data. We focus on the influence of through-plane motion on the history of magnetization. A change in object position will disrupt the tissue’s steady-state magnetization. The disruption will propagate to the next few

  14. Front-end data reduction of diagnostic signals by real-time digital filtering

    International Nuclear Information System (INIS)

    Zasche, D.; Fahrbach, H.U.; Harmeyer, E.

    1985-01-01

    Diagnostic measurements on a fusion plasma with high resolution in space, time and signal amplitude involve handling large amounts of data. In the design of the soft-X-ray pinhole camera diagnostic for JET (100 detectors in 2 cameras) a new approach to this problem was found. The analogue-to-digital conversion is performed continuously at the highest sample rate of 200 kHz, lower sample rates (10 kHz, 1 kHz, 100 Hz) are obtained by real-time digital filters which calculate weighted averages over consecutive samples and are undersampled at their outputs to reduce the data rate. At any time, the signals from all detectors are available at all possible data rates in ring buffers. Thus the appropriate data rate can always be recorded on demand (preprogrammed or triggered by the experiment). With this system a reduction of the raw data by a factor of up to 2000 (typically 200) is possible without severe loss of information

  15. Improved image quality in abdominal CT in patients who underwent treatment for hepatocellular carcinoma with small metal implants using a raw data-based metal artifact reduction algorithm

    Energy Technology Data Exchange (ETDEWEB)

    Sofue, Keitaro; Sugimura, Kazuro [Kobe University Graduate School of Medicine, Department of Radiology, Kobe, Hyogo (Japan); Yoshikawa, Takeshi; Ohno, Yoshiharu [Kobe University Graduate School of Medicine, Advanced Biomedical Imaging Research Center, Kobe, Hyogo (Japan); Kobe University Graduate School of Medicine, Division of Functional and Diagnostic Imaging Research, Department of Radiology, Kobe, Hyogo (Japan); Negi, Noriyuki [Kobe University Hospital, Division of Radiology, Kobe, Hyogo (Japan); Inokawa, Hiroyasu; Sugihara, Naoki [Toshiba Medical Systems Corporation, Otawara, Tochigi (Japan)

    2017-07-15

    To determine the value of a raw data-based metal artifact reduction (SEMAR) algorithm for image quality improvement in abdominal CT for patients with small metal implants. Fifty-eight patients with small metal implants (3-15 mm in size) who underwent treatment for hepatocellular carcinoma were imaged with CT. CT data were reconstructed by filtered back projection with and without SEMAR algorithm in axial and coronal planes. To evaluate metal artefact reduction, mean CT number (HU and SD) and artefact index (AI) values within the liver were calculated. Two readers independently evaluated image quality of the liver and pancreas and visualization of vasculature using a 5-point visual score. HU and AI values and image quality on images with and without SEMAR were compared using the paired Student's t-test and Wilcoxon signed rank test. Interobserver agreement was evaluated using linear-weighted κ test. Mean HU and AI on images with SEMAR was significantly lower than those without SEMAR (P < 0.0001). Liver and pancreas image qualities and visualizations of vasculature were significantly improved on CT with SEMAR (P < 0.0001) with substantial or almost perfect agreement (0.62 ≤ κ ≤ 0.83). SEMAR can improve image quality in abdominal CT in patients with small metal implants by reducing metallic artefacts. (orig.)

  16. Improved image quality in abdominal CT in patients who underwent treatment for hepatocellular carcinoma with small metal implants using a raw data-based metal artifact reduction algorithm

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Sugimura, Kazuro; Yoshikawa, Takeshi; Ohno, Yoshiharu; Negi, Noriyuki; Inokawa, Hiroyasu; Sugihara, Naoki

    2017-01-01

    To determine the value of a raw data-based metal artifact reduction (SEMAR) algorithm for image quality improvement in abdominal CT for patients with small metal implants. Fifty-eight patients with small metal implants (3-15 mm in size) who underwent treatment for hepatocellular carcinoma were imaged with CT. CT data were reconstructed by filtered back projection with and without SEMAR algorithm in axial and coronal planes. To evaluate metal artefact reduction, mean CT number (HU and SD) and artefact index (AI) values within the liver were calculated. Two readers independently evaluated image quality of the liver and pancreas and visualization of vasculature using a 5-point visual score. HU and AI values and image quality on images with and without SEMAR were compared using the paired Student's t-test and Wilcoxon signed rank test. Interobserver agreement was evaluated using linear-weighted κ test. Mean HU and AI on images with SEMAR was significantly lower than those without SEMAR (P < 0.0001). Liver and pancreas image qualities and visualizations of vasculature were significantly improved on CT with SEMAR (P < 0.0001) with substantial or almost perfect agreement (0.62 ≤ κ ≤ 0.83). SEMAR can improve image quality in abdominal CT in patients with small metal implants by reducing metallic artefacts. (orig.)

  17. Assessment of filament led bulbs with respect to temporal light artefacts

    DEFF Research Database (Denmark)

    Lindén, Johannes; Thorseth, Anders; Corell, Dennis Dan

    2017-01-01

    Temporal light artefacts, abbreviated TLAs (including flicker, stroboscopic effect and phantom arrays), i.e. undesired time modulation in luminance from a light source, has shown to be a threat to wider SSL adoption especially related to dimming functions and low-quality LED products. This is due...... to the effects that both noticeable and unperceivable TLAs have on human perception and wellbeing. In the present work a number of filament LED bulbs, currently available on the market, are assessed primarily with respect to TLAs, but also with respect to photometric, colorimetric and efficiency properties...

  18. A new method to compensate impedance artefacts for Li-ion batteries with integrated micro-reference electrodes

    NARCIS (Netherlands)

    Raijmakers, L.H.J.; Notten, P.H.L.; Lammers, M.J.G.

    2017-01-01

    In order to measure the electrochemical characteristics of both electrodes inside Li-ion batteries, micro-reference electrodes (μREF) turned out to be very useful. However, measuring the electrochemical impedance with respect to μREF can lead to severe measurement artefacts, making a detailed

  19. Effect of a sustained reduction in plasma free fatty acid concentration on insulin signalling and inflammation in skeletal muscle from human subjects.

    Science.gov (United States)

    Liang, Hanyu; Tantiwong, Puntip; Sriwijitkamol, Apiradee; Shanmugasundaram, Karthigayan; Mohan, Sumathy; Espinoza, Sara; Defronzo, Ralph A; Dubé, John J; Musi, Nicolas

    2013-06-01

    Free fatty acids (FFAs) have been implicated in the pathogenesis of insulin resistance. Reducing plasma FFA concentration in obese and type 2 diabetic (T2DM) subjects improves insulin sensitivity. However, the molecular mechanism by which FFA reduction improves insulin sensitivity in human subjects is not fully understood. In the present study, we tested the hypothesis that pharmacological FFA reduction enhances insulin action by reducing local (muscle) inflammation, leading to improved insulin signalling. Insulin-stimulated total glucose disposal (TGD), plasma FFA species, muscle insulin signalling, IBα protein, c-Jun phosphorylation, inflammatory gene (toll-like receptor 4 and monocyte chemotactic protein 1) expression, and ceramide and diacylglycerol (DAG) content were measured in muscle from a group of obese and T2DM subjects before and after administration of the antilipolytic drug acipimox for 7 days, and the results were compared to lean individuals. We found that obese and T2DM subjects had elevated saturated and unsaturated FFAs in plasma, and acipimox reduced all FFA species. Acipimox-induced reductions in plasma FFAs improved TGD and insulin signalling in obese and T2DM subjects. Acipimox increased IBα protein (an indication of decreased IB kinase-nuclear factor B signalling) in both obese and T2DM subjects, but did not affect c-Jun phosphorylation in any group. Acipimox also decreased inflammatory gene expression, although this reduction only occurred in T2DM subjects. Ceramide and DAG content did not change. To summarize, pharmacological FFA reduction improves insulin signalling in muscle from insulin-resistant subjects. This beneficial effect on insulin action could be related to a decrease in local inflammation. Notably, the improvements in insulin action were more pronounced in T2DM, indicating that these subjects are more susceptible to the toxic effect of FFAs.

  20. Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Kasperl, St.; Franz, M. [Fraunhofer Development Center for X-ray Technology EZRT, a cooperative dept. of the Fraunhofer Institutes IZFP Saarbrucken and IIS Erlangen, Furth (Germany)

    2007-07-01

    This article deals with the enhancement of accuracy in CT by just-in-time correction of artefacts (beam hardening, scattered radiation) caused by the interaction of X-rays with matter. The so called EAR method needs for simulation a registration of the object. Therefore the article presents two different registration concepts. (authors)

  1. Registration concepts for the just-in-time artefact correction by means of virtual computed tomography

    International Nuclear Information System (INIS)

    Kasperl, St.; Franz, M.

    2007-01-01

    This article deals with the enhancement of accuracy in CT by just-in-time correction of artefacts (beam hardening, scattered radiation) caused by the interaction of X-rays with matter. The so called EAR method needs for simulation a registration of the object. Therefore the article presents two different registration concepts. (authors)

  2. Robust frequency diversity based algorithm for clutter noise reduction of ultrasonic signals using multiple sub-spectrum phase coherence

    Energy Technology Data Exchange (ETDEWEB)

    Gongzhang, R.; Xiao, B.; Lardner, T.; Gachagan, A. [Centre for Ultrasonic Engineering, University of Strathclyde, Glasgow, G1 1XW (United Kingdom); Li, M. [School of Engineering, University of Glasgow, Glasgow, G12 8QQ (United Kingdom)

    2014-02-18

    This paper presents a robust frequency diversity based algorithm for clutter reduction in ultrasonic A-scan waveforms. The performance of conventional spectral-temporal techniques like Split Spectrum Processing (SSP) is highly dependent on the parameter selection, especially when the signal to noise ratio (SNR) is low. Although spatial beamforming offers noise reduction with less sensitivity to parameter variation, phased array techniques are not always available. The proposed algorithm first selects an ascending series of frequency bands. A signal is reconstructed for each selected band in which a defect is present when all frequency components are in uniform sign. Combining all reconstructed signals through averaging gives a probability profile of potential defect position. To facilitate data collection and validate the proposed algorithm, Full Matrix Capture is applied on the austenitic steel and high nickel alloy (HNA) samples with 5MHz transducer arrays. When processing A-scan signals with unrefined parameters, the proposed algorithm enhances SNR by 20dB for both samples and consequently, defects are more visible in B-scan images created from the large amount of A-scan traces. Importantly, the proposed algorithm is considered robust, while SSP is shown to fail on the austenitic steel data and achieves less SNR enhancement on the HNA data.

  3. Explorative Materiality and Knowledge. The Role of Creative Exploration and Artefacts in Design Research

    Directory of Open Access Journals (Sweden)

    Kristina Niedderer

    2013-08-01

    Full Text Available Juxtaposing the nature of design and the foundations of research in the traditional science and humanities disciplines puts their differences into sharp relief. The comparison highlights the key characteristics of design – its creative and experiential nature – which any design research must take into account, as well as the theoretical foundations of research. The aim of this article is to develop an understanding of the ontological, epistemological and methodological issues of design research, and to offer a framework that can embrace equally the notions of creativity and experiential knowledge, and of academic rigour. Furthermore,the potential roles of the design process and artefact within research are examined within this theoretical framework, which suggests that design processes and artefacts can – if appropriately framed – play an important partin the research process, facilitating an approach commensurate with the aims ofdesign enquiry. A case study of the Niedderer’s own work serves to illustratethe balance and integration of theory and (creative practice within the research process, and how this integration can enable a multi-layered contribution to the theoretical and practical advancement of the field.

  4. A Data-Driven Noise Reduction Method and Its Application for the Enhancement of Stress Wave Signals

    Directory of Open Access Journals (Sweden)

    Hai-Lin Feng

    2012-01-01

    Full Text Available Ensemble empirical mode decomposition (EEMD has been recently used to recover a signal from observed noisy data. Typically this is performed by partial reconstruction or thresholding operation. In this paper we describe an efficient noise reduction method. EEMD is used to decompose a signal into several intrinsic mode functions (IMFs. The time intervals between two adjacent zero-crossings within the IMF, called instantaneous half period (IHP, are used as a criterion to detect and classify the noise oscillations. The undesirable waveforms with a larger IHP are set to zero. Furthermore, the optimum threshold in this approach can be derived from the signal itself using the consecutive mean square error (CMSE. The method is fully data driven, and it requires no prior knowledge of the target signals. This method can be verified with the simulative program by using Matlab. The denoising results are proper. In comparison with other EEMD based methods, it is concluded that the means adopted in this paper is suitable to preprocess the stress wave signals in the wood nondestructive testing.

  5. Noise reduction in Lidar signal using correlation-based EMD combined with soft thresholding and roughness penalty

    Science.gov (United States)

    Chang, Jianhua; Zhu, Lingyan; Li, Hongxu; Xu, Fan; Liu, Binggang; Yang, Zhenbo

    2018-01-01

    Empirical mode decomposition (EMD) is widely used to analyze the non-linear and non-stationary signals for noise reduction. In this study, a novel EMD-based denoising method, referred to as EMD with soft thresholding and roughness penalty (EMD-STRP), is proposed for the Lidar signal denoising. With the proposed method, the relevant and irrelevant intrinsic mode functions are first distinguished via a correlation coefficient. Then, the soft thresholding technique is applied to the irrelevant modes, and the roughness penalty technique is applied to the relevant modes to extract as much information as possible. The effectiveness of the proposed method was evaluated using three typical signals contaminated by white Gaussian noise. The denoising performance was then compared to the denoising capabilities of other techniques, such as correlation-based EMD partial reconstruction, correlation-based EMD hard thresholding, and wavelet transform. The use of EMD-STRP on the measured Lidar signal resulted in the noise being efficiently suppressed, with an improved signal to noise ratio of 22.25 dB and an extended detection range of 11 km.

  6. Interference Reduction Selected Measurement Signals of Ships

    Directory of Open Access Journals (Sweden)

    Jan Monieta

    2014-08-01

    Full Text Available The paper presents problems encountered at the signal processing of mechanical values with electric methods. Depending on the measured quantity, the location of the sensors and the analysis frequency band, they are differently interferences. The article presents the results of applying the analysis of parameters of working and accompanying process marine medium speed reciprocating engines in the time, amplitude, frequency domain and wavelet analysis to select a reasonable method. The applied signal acquisition program allows you to perform some analysis of signals in different areas and the transformation of the data to other programs. The ways of interference reducing at various stages of their occurrence and analysis are presented. [b]Keywords[/b]: electrical signals, domain analysis, measurement interference

  7. Classification of EEG signals using a genetic-based machine learning classifier.

    Science.gov (United States)

    Skinner, B T; Nguyen, H T; Liu, D K

    2007-01-01

    This paper investigates the efficacy of the genetic-based learning classifier system XCS, for the classification of noisy, artefact-inclusive human electroencephalogram (EEG) signals represented using large condition strings (108bits). EEG signals from three participants were recorded while they performed four mental tasks designed to elicit hemispheric responses. Autoregressive (AR) models and Fast Fourier Transform (FFT) methods were used to form feature vectors with which mental tasks can be discriminated. XCS achieved a maximum classification accuracy of 99.3% and a best average of 88.9%. The relative classification performance of XCS was then compared against four non-evolutionary classifier systems originating from different learning techniques. The experimental results will be used as part of our larger research effort investigating the feasibility of using EEG signals as an interface to allow paralysed persons to control a powered wheelchair or other devices.

  8. False alarm reduction in BSN-based cardiac monitoring using signal quality and activity type information.

    Science.gov (United States)

    Tanantong, Tanatorn; Nantajeewarawat, Ekawit; Thiemjarus, Surapa

    2015-02-09

    False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs), the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs) can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  9. Head CT: Image quality improvement of posterior fossa and radiation dose reduction with ASiR - comparative studies of CT head examinations.

    Science.gov (United States)

    Guziński, Maciej; Waszczuk, Łukasz; Sąsiadek, Marek J

    2016-10-01

    To evaluate head CT protocol developed to improve visibility of the brainstem and cerebellum, lower bone-related artefacts in the posterior fossa and maintain patient radioprotection. A paired comparison of head CT performed without Adaptive Statistical Iterative Reconstruction (ASiR) and a clinically indicated follow-up with 40 % ASiR was acquired in one group of 55 patients. Patients were scanned in the axial mode with different scanner settings for the brain and the posterior fossa. Objective image quality analysis was performed with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective image quality analysis was based on brain structure visibility and evaluation of the artefacts. We achieved 19 % reduction of total DLP and significantly better image quality of posterior fossa structures. SNR for white and grey matter in the cerebellum were 34 % to 36 % higher, respectively, CNR was improved by 142 % and subjective analyses were better for images with ASiR. When imaging parameters are set independently for the brain and the posterior fossa imaging, ASiR has a great potential to improve CT performance: image quality of the brainstem and cerebellum is improved, and radiation dose for the brain as well as total radiation dose are reduced. •With ASiR it is possible to lower radiation dose or improve image quality •Sequentional imaging allows setting scan parameters for brain and posterior-fossa independently •We improved visibility of brainstem structures and decreased radiation dose •Total radiation dose (DLP) was decreased by 19.

  10. Analytical artefacts in the speciation of arsenic in clinical samples

    International Nuclear Information System (INIS)

    Slejkovec, Zdenka; Falnoga, Ingrid; Goessler, Walter; Elteren, Johannes T. van; Raml, Reingard; Podgornik, Helena; Cernelc, Peter

    2008-01-01

    Urine and blood samples of cancer patients, treated with high doses of arsenic trioxide were analysed for arsenic species using HPLC-HGAFS and, in some cases, HPLC-ICPMS. Total arsenic was determined with either flow injection-HGAFS in urine or radiochemical neutron activation analysis in blood fractions (in serum/plasma, blood cells). The total arsenic concentrations (during prolonged, daily/weekly arsenic trioxide therapy) were in the μg mL -1 range for urine and in the ng g -1 range for blood fractions. The main arsenic species found in urine were As(III), MA and DMA and in blood As(V), MA and DMA. With proper sample preparation and storage of urine (no preservation agents/storage in liquid nitrogen) no analytical artefacts were observed and absence of significant amounts of alleged trivalent metabolites was proven. On the contrary, in blood samples a certain amount of arsenic can get lost in the speciation procedure what was especially noticeable for the blood cells although also plasma/serum gave rise to some disappearance of arsenic. The latter losses may be attributed to precipitation of As(III)-containing proteins/peptides during the methanol/water extraction procedure whereas the former losses were due to loss of specific As(III)-complexing proteins/peptides (e.g. cysteine, metallothionein, reduced GSH, ferritin) on the column (Hamilton PRP-X100) during the separation procedure. Contemporary analytical protocols are not able to completely avoid artefacts due to losses from the sampling to the detection stage so that it is recommended to be careful with the explanation of results, particularly regarding metabolic and pharmacokinetic interpretations, and always aim to compare the sum of species with the total arsenic concentration determined independently

  11. X-ray microtomography scanner using time-delay integration for elimination of ring artefacts in the reconstructed image

    International Nuclear Information System (INIS)

    Davis, G.R.; London Univ.; Elliott, J.C.; London Univ.

    1997-01-01

    Most X-ray microtomography scanners work on the same principle as third-generation medical CT scanners, that is, the same point in each projection is measured by the same detector element. This leads to ring artefacts in the reconstructed image if the X-ray sensitivities of the individual detector elements, after any analytical correction, are not all identical. We have developed an X-ray microtomography scanner which uses the time-delay integration method of imaging with a CCD detector to average the characteristics of all the detector elements in each linear projection together. This has the added advantage of allowing specimens which are larger than the detector and X-ray field to be scanned. The device also uses a novel mechanical stage to ''average out'' inhomogeneities in the X-ray field. The results show that ring artefacts in microtomographic images are eliminated using this technique. (orig.)

  12. Active3 noise reduction

    International Nuclear Information System (INIS)

    Holzfuss, J.

    1996-01-01

    Noise reduction is a problem being encountered in a variety of applications, such as environmental noise cancellation, signal recovery and separation. Passive noise reduction is done with the help of absorbers. Active noise reduction includes the transmission of phase inverted signals for the cancellation. This paper is about a threefold active approach to noise reduction. It includes the separation of a combined source, which consists of both a noise and a signal part. With the help of interaction with the source by scanning it and recording its response, modeling as a nonlinear dynamical system is achieved. The analysis includes phase space analysis and global radial basis functions as tools for the prediction used in a subsequent cancellation procedure. Examples are given which include noise reduction of speech. copyright 1996 American Institute of Physics

  13. Jamming Signal Reduction in Spread Spectrum Systems.

    Science.gov (United States)

    1979-04-26

    the addition of an appropriate equalizer netowrk . The original signal and the estimate of the jamming signal are matched and added by a resistor...ADDRESS(SI different from Controllln~ OWce) IS. SECURITY CLASS. (of this report) Unclassified IS.. OECLASSIFICATION /DOWNGRAD IHO SCHEDULE $6. DISTRIB

  14. Decreased CSF-flow artefacts in T2 imaging of the cervical spine with periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER/BLADE)

    International Nuclear Information System (INIS)

    Ragoschke-Schumm, Andreas; Schmidt, Peter; Mayer, Thomas E.; Schumm, Julia; Reimann, Georg; Mentzel, Hans-Joachim; Kaiser, Werner A.

    2011-01-01

    The cervical spine is prone to artefacts in T2 MR-imaging due to patient movements and cerebrospinal fluid flow. The periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER/BLADE) acquisition method was developed to reduce motion artefacts. We sought to determine if T2-BLADE is superior to T2-TSE with conventional k-space reading. Twenty-five patients were examined using a 1.5 T MR-scanner. T2-weighted imaging of the cervical spine in sagittal and axial orientation using conventional or BLADE k-space reading was performed. Spinal cord, subarachnoid space, vertebrae and discs were evaluated by two independent observers using a scale from 0 (non-diagnostic) to 3 (excellent). Interobserver correlation was assessed as Cohen's kappa. Results of Mann-Whitney U test with p < 0.05 were regarded as significant. Furthermore, the investigators were asked for subjective evaluation in consensus. Overall interobserver accuracy of κ = 0.91 was obtained. Comparison of sagittal images showed better values for all investigated structures in T2-BLADE: spinal cord (TSE/BLADE: 1.52/2.04; p < 0.001), subarachnoid space (1.36/2.06; p < 0.001) and vertebrae/discs (1.66/2.86; p < 0.001). Comparison of axial images showed better values in T2-BLADE for spinal cord (1.68/1.86; p = 0.149) and vertebrae/discs (1.0/1.96: p < 0.001) while subarachnoid space was better to be evaluated in conventional T2-TSE (1.94/1.12; p < 0.001). In sagittal orientation, motion- and CSF-flow artefacts were reduced in T2-BLADE. In axial orientation, however, CSF-flow artefacts were pronounced in T2-BLADE. The image quality of the sagittal T2-BLADE sequences was significantly better than the T2-TSE and acquired in less time. In axial orientation, increased CSF-flow artefacts may reduce accuracy of structures in the subarachnoid space. (orig.)

  15. False Alarm Reduction in BSN-Based Cardiac Monitoring Using Signal Quality and Activity Type Information

    Directory of Open Access Journals (Sweden)

    Tanatorn Tanantong

    2015-02-01

    Full Text Available False alarms in cardiac monitoring affect the quality of medical care, impacting on both patients and healthcare providers. In continuous cardiac monitoring using wireless Body Sensor Networks (BSNs, the quality of ECG signals can be deteriorated owing to several factors, e.g., noises, low battery power, and network transmission problems, often resulting in high false alarm rates. In addition, body movements occurring from activities of daily living (ADLs can also create false alarms. This paper presents a two-phase framework for false arrhythmia alarm reduction in continuous cardiac monitoring, using signals from an ECG sensor and a 3D accelerometer. In the first phase, classification models constructed using machine learning algorithms are used for labeling input signals. ECG signals are labeled with heartbeat types and signal quality levels, while 3D acceleration signals are labeled with ADL types. In the second phase, a rule-based expert system is used for combining classification results in order to determine whether arrhythmia alarms should be accepted or suppressed. The proposed framework was validated on datasets acquired using BSNs and the MIT-BIH arrhythmia database. For the BSN dataset, acceleration and ECG signals were collected from 10 young and 10 elderly subjects while they were performing ADLs. The framework reduced the false alarm rate from 9.58% to 1.43% in our experimental study, showing that it can potentially assist physicians in diagnosing a vast amount of data acquired from wireless sensors and enhance the performance of continuous cardiac monitoring.

  16. Elemental analysis of artefacts - establishing external beam PIXE

    International Nuclear Information System (INIS)

    Alves, A.; Johnston, P.; Short, R.; Bubb, I.

    1999-01-01

    The development of an external PIXE facility on the 1 MV Tandetron accelerator at RMIT has led to a wide range of research possibilities. A proton beam, generated inside a vacuum is brought into air via an Au coated Kapton foil exit window (thickness 8μm, diameter 0.35mm). Monitoring of the beam intensity is achieved by detecting backscattered protons from the inside Au coating on the window. Artefacts, which may be too large to be placed inside the vacuum, are positioned in the beamline opposite the exit window. An optical system consisting of a CCD camera, alignment laser and two mirrors allows viewing of a region of the target 10mm x 10mm. This technique provides quantitative analysis of elements in the pigments used in paintings and on ceramics, which is a valuable tool in art conservation and authentication. Application of the technique to a ceramic sample from the historic house 'Viewbank' is described

  17. Comparison of Selected Properties of Shellac Varnish for Restoration and Polyurethane Varnish for Reconstruction of Historical Artefacts

    Directory of Open Access Journals (Sweden)

    Kristýna Šimůnková

    2018-03-01

    Full Text Available At present, many historical artefacts and furniture are only reconstructed and not restored. They are preserved in terms of material reparation, but their historical value decreases significantly. This work is focused on the comparison of the resistance of high-gloss polyurethane varnish with traditional shellac varnish. The varnishes were applied to oak wood and exposed to interior artificial accelerated ageing in Xenotest. Before and after ageing, cold liquid-resistance tests were performed on the tested specimens and gloss, colour, and adhesion were also evaluated. The structures of the surfaces were also analysed using a confocal laser scanning microscope. As expected, polyurethane varnish was much more durable than shellac varnish. Interestingly, shellac varnish was fairly resistant to water at the beginning, but this resistance was greatly reduced after artificial accelerated ageing. This illustrates the importance of sheltering the shellac treated artefacts in stable temperature-humidity conditions with the least possible effect of solar radiation.

  18. The use of radiation in the study of cultural heritage artefacts

    Science.gov (United States)

    Creagh, Dudley; Otieno-Alego, Vincent; Treasure, Alana; Kubik, Maria; Hallam, David

    2017-08-01

    Patrons of art galleries and museums, tourists visiting historic buildings, and sightseers viewing archaeological sites are generally unaware of the extent to which science and technology has contributed to the value of what they see. Many countries rely on cultural tourism to generate national wealth. The use of radiation of many kinds to assist in the conservation/restoration of cultural heritage artefacts is described in this paper. In particular, the paper will describe studies of the pigments used in historic Australian Indigenous art, the degradation of manuscripts written using iron-gall inks, the protection of statues against corrosion and the selection of lubricants for use in old machinery.

  19. Plasma cleaning and analysis of archeological artefacts from Sipán

    Science.gov (United States)

    Saettone, E. A. O.; da Matta, J. A. S.; Alva, W.; Chubaci, J. F. O.; Fantini, M. C. A.; Galvão, R. M. O.; Kiyohara, P.; Tabacniks, M. H.

    2003-04-01

    A novel procedure using plasma sputtering in an electron-cyclotron-resonance device has been applied to clean archeological MOCHE artefacts, unearthed at the Royal Tombs of Sipán. After successful cleaning, the pieces were analysed by a variety of complementary techniques, namely proton-induced x-ray emission, Rutherford backscattering spectroscopy, x-ray diffraction, electron microscopy, and inductively coupled plasma mass spectroscopy. With these techniques, it has been possible to not only determine the profiles of the gold and silver surface layers, but also to detect elements that may be relevant to explain the gilding techniques skillfully developed by the metal smiths of the MOCHE culture.

  20. Human brain receptor autoradiography using whole hemisphere sections: a general method that minimizes tissue artefacts

    International Nuclear Information System (INIS)

    Quirion, R.; Robitaille, Y.; Martial, J.; Chabot, J.G.; Lemoine, P.; Pilapil, C.; Dalpe, M.

    1987-01-01

    A general method for the preparation of high-quality, mostly ice-crystal-artefact-free whole human brain hemisphere sections is described. Upon receipt, hemispheres are divided; one is then fixed in buffered 10% formalin for neuropathological analysis while the other is cut in 8-10-mm-thick coronal slices that are then rapidly frozen in 2-methylbutane at -40 degrees C (10-15 sec) before being placed in the brain bank at -80 degrees C. Such rapid freezing markedly decreases the formation of ice-crystal artefacts. Whole-hemisphere 20-micron thick sections are then cut and mounted onto lantern-type gelatin-coated slides. These sections are subsequently used for both qualitative and quantitative in vitro receptor autoradiography. Examples of data obtained are given by using various radioligands labelling classical neutrotransmitter, neuropeptide, enzyme, and ion channel receptor binding sites. This method should be useful for the obtention of various receptor maps in human brain. Such information could be most useful for in vivo receptor visualization studies using positron emission tomography (PET) scanning. It could also indicate if a given receptor population is specifically and selectively altered in certain brain diseases, eventually leading to the development of new therapeutic approaches

  1. Artefact in Physiological Data Collected from Patients with Brain Injury: Quantifying the Problem and Providing a Solution Using a Factorial Switching Linear Dynamical Systems Approach.

    Science.gov (United States)

    Georgatzis, Konstantinos; Lal, Partha; Hawthorne, Christopher; Shaw, Martin; Piper, Ian; Tarbert, Claire; Donald, Rob; Williams, Christopher K I

    2016-01-01

    High-resolution, artefact-free and accurately annotated physiological data are desirable in patients with brain injury both to inform clinical decision-making and for intelligent analysis of the data in applications such as predictive modelling. We have quantified the quality of annotation surrounding artefactual events and propose a factorial switching linear dynamical systems (FSLDS) approach to automatically detect artefact in physiological data collected in the neurological intensive care unit (NICU). Retrospective analysis of the BrainIT data set to discover potential hypotensive events corrupted by artefact and identify the annotation of associated clinical interventions. Training of an FSLDS model on clinician-annotated artefactual events in five patients with severe traumatic brain injury. In a subset of 187 patients in the BrainIT database, 26.5 % of potential hypotensive events were abandoned because of artefactual data. Only 30 % of these episodes could be attributed to an annotated clinical intervention. As assessed by the area under the receiver operating characteristic curve metric, FSLDS model performance in automatically identifying the events of blood sampling, arterial line damping and patient handling was 0.978, 0.987 and 0.765, respectively. The influence of artefact on physiological data collected in the NICU is a significant problem. This pilot study using an FSLDS approach shows real promise and is under further development.

  2. Preservation of archaeological artefacts by γ-ray induced polymerization technique

    International Nuclear Information System (INIS)

    Gueven, O.

    1983-01-01

    For the preservation and consolidation of archaeological artefacts irradiation of these objects with γ-rays seems to be a very promising method. In situ polymerization of monomers impregnated in the capillaries and cavities of the objects by γ-rays provides a simultaneous sterilization and consolidation effect. In the present work this method of preservation is applied to some XIIth century ceramic findings belonging to Seljuk period found in South-East Anatolia. Monomer impregnation is restricted to the surfaces of the objects. The colored figures and structures which are present but not perceptible on these objects became fully apparent upon polymerizing hydrophilic monomers on their surfaces. Crosslinking of the top polymer layer further provides a permanent protection of the substrate material. (author)

  3. Towards a Knowledge Communication Perspective on Designing Artefacts Supporting Knowledge Work

    Directory of Open Access Journals (Sweden)

    Niclas Eberhagen

    2015-02-01

    Full Text Available The designing of computer-based artefacts to support knowledge work is far from a straightforward rational process. Characteristics of knowledge work have a bearing upon how developers (or designers, together with users, come to approach and capture the rich and tacit knowing of the practice. As all knowledge work is about the production of knowledge, transforming it, so is the design practice for developing artefacts to occupy space within that same practice. There is a need for providing a conceptual language to better reflect the nature of this design work that goes beyond those dressed in the managerial (or rational language of planned activities and deliverables. Towards this end, a conceptual frame is presented that makes several important aspects of the design practice visible. The frame brings together both nature of design work and characteristics of knowledge work to extend the frame of knowledge in user-developer communication of Kensing and Munk-Madsen. Thereby, providing a means to focus attention and dress debate on what situated designing is. By using explicit concepts, such as types knowledge domains embedded in the design situation, the transitional paths between them, and design engagements, it arms practitioners with specific linguistic constructs to direct attention and efforts in planning and organizing development undertakings.Purpose – the purpose of this work is to present and argue for a perspective on designing of computer-based artefacts supporting knowledge work. This is done to inform practitioners, directing their attention and dressing debate, and providing a conceptual language to better capture design activities in planning and organizing development undertakings.Design/Methodology/Approach – The approach presented in this article is conceptual in so far that a model or frame providing linguistic constructs is constructed and argued, building upon scholarly work of knowledge communication and drawing upon

  4. Noise Reduction Effect of Multiple-Sampling-Based Signal-Readout Circuits for Ultra-Low Noise CMOS Image Sensors

    Directory of Open Access Journals (Sweden)

    Shoji Kawahito

    2016-11-01

    Full Text Available This paper discusses the noise reduction effect of multiple-sampling-based signal readout circuits for implementing ultra-low-noise image sensors. The correlated multiple sampling (CMS technique has recently become an important technology for high-gain column readout circuits in low-noise CMOS image sensors (CISs. This paper reveals how the column CMS circuits, together with a pixel having a high-conversion-gain charge detector and low-noise transistor, realizes deep sub-electron read noise levels based on the analysis of noise components in the signal readout chain from a pixel to the column analog-to-digital converter (ADC. The noise measurement results of experimental CISs are compared with the noise analysis and the effect of noise reduction to the sampling number is discussed at the deep sub-electron level. Images taken with three CMS gains of two, 16, and 128 show distinct advantage of image contrast for the gain of 128 (noise(median: 0.29 e−rms when compared with the CMS gain of two (2.4 e−rms, or 16 (1.1 e−rms.

  5. Hyoscine butylbromide significantly decreases motion artefacts and allows better delineation of anatomic structures in mp-MRI of the prostate

    Energy Technology Data Exchange (ETDEWEB)

    Ullrich, T.; Quentin, M.; Schmaltz, A.K.; Rubbert, C.; Blondin, D.; Antoch, G.; Schimmoeller, L. [University Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Arsov, C.; Rabenalt, R.; Albers, P. [University Dusseldorf, Medical Faculty, Department of Urology, Dusseldorf (Germany)

    2018-01-15

    To prospectively evaluate the effect of hyoscine butylbromide (HBB) on visualisation of anatomical details and motion-related artefacts in mp-MRI of the prostate at 3.0 Tesla. One hundred and three consecutive patients (65 ± 10 years) were included in this trial, powered to demonstrate an improvement of image quality after HBB administration, assessed on a 5-point scale by two blinded readers. All patients received high-spatial resolution axial T2-weighted TSE sequences at 3.0 T without spasmolytic agent, repeated after application of 40 mg HBB and followed by routine mp-MRI. Secondary endpoints were (1) susceptibility to side effects, (2) dependence of spasmolytic effect on patients and acute; weight, and (3) prostate volume. In 68% of patients, HBB significantly improved the anatomic score (mean 3.4 ± 0.9 before and 4.4 ± 0.7 after HBB for both readers, p = <0.001). In 67%, HBB significantly enhanced the artefact score (mean 3.2 ± 1 before and 4.2 ± 0.8 after HBB for reader 1, p = <0.001; 3.2 ± 1 and 4.1 ± 0.8 for reader 2, p = <0.001). Subgroup analysis revealed no statistically significant difference between patients with different bodyweight or prostate volume. Inter-reader agreement was excellent (k = 0.95-0.98). Hyoscine butylbromide significantly improves image quality and reduces motion-related artefacts in mp-MRI of the prostate independent of bodyweight or prostate volume. No side effects were reported. (orig.)

  6. Hyoscine butylbromide significantly decreases motion artefacts and allows better delineation of anatomic structures in mp-MRI of the prostate

    International Nuclear Information System (INIS)

    Ullrich, T.; Quentin, M.; Schmaltz, A.K.; Rubbert, C.; Blondin, D.; Antoch, G.; Schimmoeller, L.; Arsov, C.; Rabenalt, R.; Albers, P.

    2018-01-01

    To prospectively evaluate the effect of hyoscine butylbromide (HBB) on visualisation of anatomical details and motion-related artefacts in mp-MRI of the prostate at 3.0 Tesla. One hundred and three consecutive patients (65 ± 10 years) were included in this trial, powered to demonstrate an improvement of image quality after HBB administration, assessed on a 5-point scale by two blinded readers. All patients received high-spatial resolution axial T2-weighted TSE sequences at 3.0 T without spasmolytic agent, repeated after application of 40 mg HBB and followed by routine mp-MRI. Secondary endpoints were (1) susceptibility to side effects, (2) dependence of spasmolytic effect on patients and acute; weight, and (3) prostate volume. In 68% of patients, HBB significantly improved the anatomic score (mean 3.4 ± 0.9 before and 4.4 ± 0.7 after HBB for both readers, p = <0.001). In 67%, HBB significantly enhanced the artefact score (mean 3.2 ± 1 before and 4.2 ± 0.8 after HBB for reader 1, p = <0.001; 3.2 ± 1 and 4.1 ± 0.8 for reader 2, p = <0.001). Subgroup analysis revealed no statistically significant difference between patients with different bodyweight or prostate volume. Inter-reader agreement was excellent (k = 0.95-0.98). Hyoscine butylbromide significantly improves image quality and reduces motion-related artefacts in mp-MRI of the prostate independent of bodyweight or prostate volume. No side effects were reported. (orig.)

  7. Imaging of fullerene-like structures in CNx thin films by electron microscopy; sample preparation artefacts due to ion-beam milling

    International Nuclear Information System (INIS)

    Czigany, Zs.; Neidhardt, J.; Brunell, I.F.; Hultman, L.

    2003-01-01

    The microstructure of CN x thin films, deposited by reactive magnetron sputtering, was investigated by transmission electron microscopy (TEM) at 200 kV in plan-view and cross-sectional samples. Imaging artefacts arise in high-resolution TEM due to overlap of nm-sized fullerene-like features for specimen thickness above 5 nm. The thinnest and apparently artefact-free areas were obtained at the fracture edges of plan-view specimens floated-off from NaCl substrates. Cross-sectional samples were prepared by ion-beam milling at low energy to minimize sample preparation artefacts. The depth of the ion-bombardment-induced surface amorphization was determined by TEM cross sections of ion-milled fullerene-like CN x surfaces. The thickness of the damaged surface layer at 5 deg. grazing incidence was 13 and 10 nm at 3 and 0.8 keV, respectively, which is approximately three times larger than that observed on Si prepared under the same conditions. The shallowest damage depth, observed for 0.25 keV, was less than 1 nm. Chemical changes due to N loss and graphitization were also observed by X-ray photoelectron spectroscopy. As a consequence of chemical effects, sputtering rates of CN x films were similar to that of Si, which enables relatively fast ion-milling procedure compared to carbon compounds. No electron beam damage of fullerene-like CN x was observed at 200 kV

  8. Gravel size matters: Early Middle Palaeolithic artefacts made from local Rhine and Meuse deposits in the central Netherlands

    NARCIS (Netherlands)

    van den Biggelaar, D.F.A.M.; van Balen, R.T.; Kluiving, S.J.; Verpoorte, A.; Alink, A

    2016-01-01

    The artefact size of the Early Middle Palaeolithic (EMP) assemblages in ice-pushed Rhine–Meuse deposits in the central Netherlands decreases northwestward. This trend correlates to the downstream fining direction of the Rhine–Meuse fluvial system, the source of the rock material, showing that

  9. The usefulness of ultrasound colour-Doppler twinkling artefact for detecting urolithiasis compared with low dose nonenhanced computerized tomography

    DEFF Research Database (Denmark)

    Winkel, Rikke Rass; Kalhauge, Anna; Fredfeldt, Knud-Erik

    2012-01-01

    This prospective study evaluates the usefulness of the twinkling artefact (TA) seen on colour-Doppler ultrasound (US) in diagnosing urolithiasis. US and standard computed tomography (CT) were performed blinded on 105 patients. B-mode US and colour-Doppler used separately and in combination showed...

  10. Detection of Noise in Composite Step Signal Pattern by Visualizing Signal Waveforms

    Directory of Open Access Journals (Sweden)

    Chaman Verma

    2018-03-01

    Full Text Available The Step Composite Signals is the combination of vital informative signals that are compressed and coded to produce a predefined test image on a display device. It carries the desired sequence of information from source to destination. This information may be transmitted as digital signal, video information or data signal required as an input for the destination module. For testing of display panels, Composite Test Signals are the most important attribute of test signal transmission system. In the current research paper we present an approach for the noise detection in Composite Step Signal by analysing Composite Step Signal waveforms. The analysis of the signal waveforms reveals that the noise affected components of the signal and subsequently noise reduction process is initiated which targets noisy signal component only. Thus the quality of signal is not compromised during noise reduction process.

  11. Suitability of cerebrospinal fluid as a signal-intensity reference on MRI: evaluation of signal-intensity variations in the lumbosacral dural sac

    International Nuclear Information System (INIS)

    Luoma, E.K.; Luukkonen, R.; Riihimaeki, H.A.; Raininko, R.; Manninen, H.I.; Nummi, P.J.

    1997-01-01

    The suitability of the cerebrospinal fluid (CSF) in the lumbosacral dural sac as an internal signal-intensity reference was studied on magnetic resonance imaging (MRI) of the lumbar spine using a surface coil and motion artefact suppression technique. A signal-intensity reference is needed when signal is compared between images, studies or subjects. Homogeneity of the CSF was estimated visually on T2-weighted images of 60 subjects at 1.5 T and of another 60 subjects at 0.1 T. Spines with a severely narrowed dural sac or marked scoliosis were excluded from the study to avoid partial volume effect. CSF was homogeneous in 82% and 73% of the examinations at 1.5 T and 0.1 T, respectively. The type and location of the local inhomogeneities did not relate to local narrowings of the dural sac. The signal intensity of CSF was measured in 108 examinations at 0.1 T after correcting the spatially-dependent signal-intensity nonuniformities with a phantom-based method. The signal-intensity difference between the CSF in the upper and lower lumbar dural sac was less than 10% in 73% of the examinations. The CSF in the lumbosacral dural sac can be a useful signal-intensity reference for estimation of the signal of the adjacent structures in patients without severe narrowing of the dural sac or marked scoliosis. It may contribute to assessing spinal disease processes. (orig.). With 1 fig., 3 tabs

  12. Interior lives : the age and interpretation of perishable artefacts from Maori rockshelter sites in inland Otago, New Zealand

    International Nuclear Information System (INIS)

    Anderson, A.; White, M.; Petchey, F.

    2015-01-01

    Rockshelter and similar sites in inland Otago have produced a relatively large number of M?ori artefacts made in readily perishable materials such as flax leaves and fibre, tussock grass or tapa (bark) cloth. Regional preservation is clearly related broadly to the relatively arid climate. However, AMS radiocarbon dates on 11 samples from 10 sites shows that while a few date to the 17th century or earlier, the ages of most cluster in the 18th to early 19th centuries. We argue that this represents a phase of accelerated deposition in which material was left behind deliberately, as logistically-determined storage for future use in a strategic plan for exploiting inland resources. We propose that such a process of 'furnishing the landscape' with useful artefacts and stored raw materials became possible when territorial security was achieved by the extension of immigrant tribal authority over the inland region. (author).

  13. Solvent Composition-Dependent Signal-Reduction of Molecular Ions Generated from Aromatic Compounds in (+) Atmospheric Pressure Photo Ionization Mass Spectrometry.

    Science.gov (United States)

    Lee, Seulgidaun; Ahmed, Arif; Kim, Sunghwan

    2018-03-30

    The ionization process is essential for successful mass spectrometry (MS) analysis because of its influence on selectivity and sensitivity. In particular, certain solvents reduce the ionization of the analyte, thereby reducing the overall sensitivity in APPI. Since the sensitivity varies greatly depending on the solvents, a fundamental understanding of the mechanism is required. Standard solutions were analyzed by (+) Atmospheric pressure photo ionization (APPI) QExactive ion trap mass spectrometer (Thermo Scientific). Each solution was infused directly to the APPI source at a flow rate 100 μl/min and the APPI source temperature was 300 °C. Other operating mass spectrometric parameters were maintained under the same conditions. Quantum mechanical calculations were carried out using the Gaussian 09 suite program. Density functional theory was used to calculate the reaction enthalpies (∆H) of reaction between toluene and other solvents. The experimental and theoretical results showed good agreement. The abundances of analyte ions were well correlated with the calculated ∆H values. Therefore, the results strongly support the suggested signal reduction mechanism. In addition, linear correlations between the abundance of toluene and analyte molecular ions were observed, which also supports the suggested mechanism. A solvent composition-dependent signal reduction mechanism was suggested and evaluated for the (+) atmospheric pressure photo ionization (APPI) mass spectrometry analysis of poly-aromatic hydrocarbons (PAHs) generating mainly molecular ions. Overall, the evidence provided in this work suggests that reactions between solvent cluster(s) and toluene molecular ions are responsible for the observed signal reductions. This article is protected by copyright. All rights reserved.

  14. The use of adaptive statistical iterative reconstruction (ASiR) technique in evaluation of patients with cervical spine trauma: impact on radiation dose reduction and image quality.

    Science.gov (United States)

    Patro, Satya N; Chakraborty, Santanu; Sheikh, Adnan

    2016-01-01

    The aim of this study was to evaluate the impact of adaptive statistical iterative reconstruction (ASiR) technique on the image quality and radiation dose reduction. The comparison was made with the traditional filtered back projection (FBP) technique. We retrospectively reviewed 78 patients, who underwent cervical spine CT for blunt cervical trauma between 1 June 2010 and 30 November 2010. 48 patients were imaged using traditional FBP technique and the remaining 30 patients were imaged using the ASiR technique. The patient demographics, radiation dose, objective image signal and noise were recorded; while subjective noise, sharpness, diagnostic acceptability and artefacts were graded by two radiologists blinded to the techniques. We found that the ASiR technique was able to reduce the volume CT dose index, dose-length product and effective dose by 36%, 36.5% and 36.5%, respectively, compared with the FBP technique. There was no significant difference in the image noise (p = 0.39), signal (p = 0.82) and signal-to-noise ratio (p = 0.56) between the groups. The subjective image quality was minimally better in the ASiR group but not statistically significant. There was excellent interobserver agreement on the subjective image quality and diagnostic acceptability for both groups. The use of ASiR technique allowed approximately 36% radiation dose reduction in the evaluation of cervical spine without degrading the image quality. The present study highlights that the ASiR technique is extremely helpful in reducing the patient radiation exposure while maintaining the image quality. It is highly recommended to utilize this novel technique in CT imaging of different body regions.

  15. 4D MR imaging using robust internal respiratory signal

    International Nuclear Information System (INIS)

    Hui, CheukKai; Wen, Zhifei; Beddar, Sam; Stemkens, Bjorn; Tijssen, R H N; Van den Berg, C A T; Hwang, Ken-Pin

    2016-01-01

    The purpose of this study is to investigate the feasibility of using internal respiratory (IR) surrogates to sort four-dimensional (4D) magnetic resonance (MR) images. The 4D MR images were constructed by acquiring fast 2D cine MR images sequentially, with each slice scanned for more than one breathing cycle. The 4D volume was then sorted retrospectively using the IR signal. In this study, we propose to use multiple low-frequency components in the Fourier space as well as the anterior body boundary as potential IR surrogates. From these potential IR surrogates, we used a clustering algorithm to identify those that best represented the respiratory pattern to derive the IR signal. A study with healthy volunteers was performed to assess the feasibility of the proposed IR signal. We compared this proposed IR signal with the respiratory signal obtained using respiratory bellows. Overall, 99% of the IR signals matched the bellows signals. The average difference between the end inspiration times in the IR signal and bellows signal was 0.18 s in this cohort of matching signals. For the acquired images corresponding to the other 1% of non-matching signal pairs, the respiratory motion shown in the images was coherent with the respiratory phases determined by the IR signal, but not the bellows signal. This suggested that the IR signal determined by the proposed method could potentially correct the faulty bellows signal. The sorted 4D images showed minimal mismatched artefacts and potential clinical applicability. The proposed IR signal therefore provides a feasible alternative to effectively sort MR images in 4D. (paper)

  16. Unicompartmental knee arthroplasty MRI: impact of slice-encoding for metal artefact correction MRI on image quality, findings and therapy decision

    International Nuclear Information System (INIS)

    Agten, Christoph A.; Pfirrmann, Christian W.A.; Sutter, Reto; Grande, Filippo del; Fucentese, Sandro F.; Blatter, Samuel

    2015-01-01

    To evaluate the impact of slice-encoding for metal artefact correction (SEMAC) on image quality, findings, and therapy decision in patients with unicompartmental knee arthroplasty (UKA). Forty-five painful UKAs were examined at 1.5T-MRI (STIR, proton-density(PD)-weighted sequence, each with SEMAC and high-bandwidth). Artefact size, image quality, anatomic depiction, and clinically relevant findings were compared between SEMAC and high-bandwidth (2 readers). In 30 patients, therapy decision was retrospectively assessed by two orthopaedic surgeons without MRI, with high-bandwidth-MRI, and with SEMAC-MRI. SEMAC reduced mean artefact size for STIR (11.8 cm 2 vs. 37.7 cm 2 ) and PD (16.8 cm 2 vs. 18.9 cm 2 ), p < 0.0005 for both comparisons. SEMAC showed more blurring than high-bandwidth, p < 0.0005. STIR-SEMAC revealed more bone marrow oedema (29 vs. 18 patients, p = 0.001, 30 vs. 13 patients, p < 0.0005, for reader 1 and 2 respectively). PD-SEMAC was worse in detecting meniscal lesions (6 missed, p = 0.031, 9 missed, p = 0.004, by reader 1 and 2 respectively) than PD-high-bandwidth. Revision-surgery was chosen in 12 and 11 patients without MRI (surgeon 1 and 2), with high-bandwidth-MRI in 15 and 14 patients, and with SEMAC-MRI in 19 and 14 patients. STIR-SEMAC was useful in detecting bone marrow oedema and influenced the orthopaedic surgeons' decisions towards surgery, while PD-SEMAC showed no clinical benefit. (orig.)

  17. The role of movies in Norwegiantextbooks. : A study of film as artefact in religious education.

    OpenAIRE

    Vestøl, Jon Magne

    2012-01-01

    Drawing on perspectives on educational design, this article investigates the role of movies in Norwegian secondary school textbooks on religious education, including teachers’ handbooks and textbook websites. All passages containing references to films or movies have been included in the analysis. The distribution of references indicates that a film is an optional artefact and that movies are drawn mainly from a Western cinematic tradition and are related to topics such as Christianity and et...

  18. The effect of metal artefact reduction on CT-based attenuation correction for PET imaging in the vicinity of metallic hip implants: a phantom study.

    Science.gov (United States)

    Harnish, Roy; Prevrhal, Sven; Alavi, Abass; Zaidi, Habib; Lang, Thomas F

    2014-07-01

    To determine if metal artefact reduction (MAR) combined with a priori knowledge of prosthesis material composition can be applied to obtain CT-based attenuation maps with sufficient accuracy for quantitative assessment of (18)F-fluorodeoxyglucose uptake in lesions near metallic prostheses. A custom hip prosthesis phantom with a lesion-sized cavity filled with 0.2 ml (18)F-FDG solution having an activity of 3.367 MBq adjacent to a prosthesis bore was imaged twice with a chrome-cobalt steel hip prosthesis and a plastic replica, respectively. Scanning was performed on a clinical hybrid PET/CT system equipped with an additional external (137)Cs transmission source. PET emission images were reconstructed from both phantom configurations with CT-based attenuation correction (CTAC) and with CT-based attenuation correction using MAR (MARCTAC). To compare results with the attenuation-correction method extant prior to the advent of PET/CT, we also carried out attenuation correction with (137)Cs transmission-based attenuation correction (TXAC). CTAC and MARCTAC images were scaled to attenuation coefficients at 511 keV using a trilinear function that mapped the highest CT values to the prosthesis alloy attenuation coefficient. Accuracy and spatial distribution of the lesion activity was compared between the three reconstruction schemes. Compared to the reference activity of 3.37 MBq, the estimated activity quantified from the PET image corrected by TXAC was 3.41 MBq. The activity estimated from PET images corrected by MARCTAC was similar in accuracy at 3.32 MBq. CTAC corrected PET images resulted in nearly 40 % overestimation of lesion activity at 4.70 MBq. Comparison of PET images obtained with the plastic and metal prostheses in place showed that CTAC resulted in a marked distortion of the (18)F-FDG distribution within the lesion, whereas application of MARCTAC and TXAC resulted in lesion distributions similar to those observed with the plastic replica. MAR combined

  19. Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases.

    Science.gov (United States)

    Schäfer, M-L; Lüdemann, L; Böning, G; Kahn, J; Fuchs, S; Hamm, B; Streitparth, F

    2016-05-01

    To compare the radiation dose and image quality of 64-row chest computed tomography (CT) in patients with bronchial carcinoma or intrapulmonary metastases using full-dose CT reconstructed with filtered back projection (FBP) at baseline and reduced dose with 40% adaptive statistical iterative reconstruction (ASIR) at follow-up. The chest CT images of patients who underwent FBP and ASIR studies were reviewed. Dose-length products (DLP), effective dose, and size-specific dose estimates (SSDEs) were obtained. Image quality was analysed quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurement. In addition, image quality was assessed by two blinded radiologists evaluating images for noise, contrast, artefacts, visibility of small structures, and diagnostic acceptability using a five-point scale. The ASIR studies showed 36% reduction in effective dose compared with the FBP studies. The qualitative and quantitative image quality was good to excellent in both protocols, without significant differences. There were also no significant differences for SNR except for the SNR of lung surrounding the tumour (FBP: 35±17, ASIR: 39±22). A protocol with 40% ASIR can provide approximately 36% dose reduction in chest CT of patients with bronchial carcinoma or intrapulmonary metastases while maintaining excellent image quality. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  20. Anatomical studies of timber and EPMA analysis of brass artefacts collected from steam engine shipwreck of Minicoy Island, Lakshadweep, India

    Digital Repository Service at National Institute of Oceanography (India)

    Tripati, S.; Shukla, S.R.; Som, V.; Sundaresh; Khedekar, V.; Shashikala, S.; Sharma, S.K.

    construction but also for anchors. During exploration of shipwreck off Minicoy doorframe hinge, latch, porthole, flanges, J hook were found and all these artefacts are made of brass. Moreover timber remains noticed on doorframe hinge and latch. In order...

  1. Noise Reduction of MEMS Gyroscope Based on Direct Modeling for an Angular Rate Signal

    Directory of Open Access Journals (Sweden)

    Liang Xue

    2015-02-01

    Full Text Available In this paper, a novel approach for processing the outputs signal of the microelectromechanical systems (MEMS gyroscopes was presented to reduce the bias drift and noise. The principle for the noise reduction was presented, and an optimal Kalman filter (KF was designed by a steady-state filter gain obtained from the analysis of KF observability. In particular, the true angular rate signal was directly modeled to obtain an optimal estimate and make a self-compensation for the gyroscope without needing other sensor’s information, whether in static or dynamic condition. A linear fit equation that describes the relationship between the KF bandwidth and modeling parameter of true angular rate was derived from the analysis of KF frequency response. The test results indicated that the MEMS gyroscope having an ARW noise of 4.87°/h0.5 and a bias instability of 44.41°/h were reduced to 0.4°/h0.5 and 4.13°/h by the KF under a given bandwidth (10 Hz, respectively. The 1σ estimated error was reduced from 1.9°/s to 0.14°/s and 1.7°/s to 0.5°/s in the constant rate test and swing rate test, respectively. It also showed that the filtered angular rate signal could well reflect the dynamic characteristic of the input rate signal in dynamic conditions. The presented algorithm is proved to be effective at improving the measurement precision of the MEMS gyroscope.

  2. Compensation for the signal processing characteristics of ultrasound B-mode scanners in adaptive speckle reduction.

    Science.gov (United States)

    Crawford, D C; Bell, D S; Bamber, J C

    1993-01-01

    A systematic method to compensate for nonlinear amplification of individual ultrasound B-scanners has been investigated in order to optimise performance of an adaptive speckle reduction (ASR) filter for a wide range of clinical ultrasonic imaging equipment. Three potential methods have been investigated: (1) a method involving an appropriate selection of the speckle recognition feature was successful when the scanner signal processing executes simple logarithmic compressions; (2) an inverse transform (decompression) of the B-mode image was effective in correcting for the measured characteristics of image data compression when the algorithm was implemented in full floating point arithmetic; (3) characterising the behaviour of the statistical speckle recognition feature under conditions of speckle noise was found to be the method of choice for implementation of the adaptive speckle reduction algorithm in limited precision integer arithmetic. In this example, the statistical features of variance and mean were investigated. The third method may be implemented on commercially available fast image processing hardware and is also better suited for transfer into dedicated hardware to facilitate real-time adaptive speckle reduction. A systematic method is described for obtaining ASR calibration data from B-mode images of a speckle producing phantom.

  3. FT-Raman and FT-Infrared investigations of archaeological artefacts from Foeni Neolithic site (Banat, Romania)

    OpenAIRE

    Simona Cîntă Pînzaru; Dana Pop; Loredana Nemeth

    2008-01-01

    An impressive collection of chert artefacts from the Foeni Neolithic archaeological site (Timiş County, Banat region, Romania) is hosted by the Banat Museum in Timişoara. A representative set of seven specimens was non-destructively investigated using FT-Raman and ATR-FT-IR spectroscopy. The research was carried out for checking if these readily-available, non-destructive, fast, and cheap methods, which do not require preliminary sample preparation could provide significant information for ch...

  4. Radiation dose reduction in CT with adaptive statistical iterative reconstruction (ASIR) for patients with bronchial carcinoma and intrapulmonary metastases

    International Nuclear Information System (INIS)

    Schäfer, M.-L.; Lüdemann, L.; Böning, G.; Kahn, J.; Fuchs, S.; Hamm, B.; Streitparth, F.

    2016-01-01

    Aim: To compare the radiation dose and image quality of 64-row chest computed tomography (CT) in patients with bronchial carcinoma or intrapulmonary metastases using full-dose CT reconstructed with filtered back projection (FBP) at baseline and reduced dose with 40% adaptive statistical iterative reconstruction (ASIR) at follow-up. Materials and methods: The chest CT images of patients who underwent FBP and ASIR studies were reviewed. Dose–length products (DLP), effective dose, and size-specific dose estimates (SSDEs) were obtained. Image quality was analysed quantitatively by signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) measurement. In addition, image quality was assessed by two blinded radiologists evaluating images for noise, contrast, artefacts, visibility of small structures, and diagnostic acceptability using a five-point scale. Results: The ASIR studies showed 36% reduction in effective dose compared with the FBP studies. The qualitative and quantitative image quality was good to excellent in both protocols, without significant differences. There were also no significant differences for SNR except for the SNR of lung surrounding the tumour (FBP: 35±17, ASIR: 39±22). Discussion: A protocol with 40% ASIR can provide approximately 36% dose reduction in chest CT of patients with bronchial carcinoma or intrapulmonary metastases while maintaining excellent image quality. - Highlights: • adaptive statistical iterative reconstruction in chest computed tomography scans. • patients with bronchial carcinoma or intrapulmonary metastases. • ASIR studies showed 36% reduction in effective dose compared with the FBP studies. • the qualitative and quantitative image quality was good to excellent in both protocols.

  5. Simultaneous EEG–fMRI: evaluating the effect of the cabling configuration on the gradient artefact

    International Nuclear Information System (INIS)

    Chowdhury, M E H; Mullinger, Karen J; Bowtell, Richard

    2015-01-01

    EEG recordings made in combined EEG–fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artefacts are also produced in the cables used to connect the EEG cap to the amplifier. The aim of this study is to measure the effects of the connecting cable configuration on the characteristics of the GA. We measured the GA produced on two different cable configurations (a ribbon cable and a cable consisting of wires that are twisted together to form a cylindrical bundle) by gradient pulses applied on three orthogonal axes and also characterized the effect of each cable configuration on the GA generated by a multi-slice echo planar imaging sequence, as employed in typical EEG–fMRI studies. The results demonstrate that the cabling that connects the EEG cap to the amplifier can make a significant contribution to the GA recorded during EEG–fMRI studies. In particular, we demonstrate that the GA generated by a ribbon cable is larger than that produced using a twisted cable arrangement and that changes in the GA resulting from variation in the cable position are also greater for the ribbon cable. (note)

  6. Simultaneous EEG-fMRI: evaluating the effect of the cabling configuration on the gradient artefact

    Science.gov (United States)

    Chowdhury, M. E. H.; Mullinger, Karen J.; Bowtell, Richard

    2015-06-01

    EEG recordings made in combined EEG-fMRI studies are corrupted by gradient artefacts (GAs) resulting from the interaction of the EEG system with the time-varying magnetic field gradients used in MRI. The dominant contribution to the GA arises from interaction with the leads of the EEG cap and the human head, but artefacts are also produced in the cables used to connect the EEG cap to the amplifier. The aim of this study is to measure the effects of the connecting cable configuration on the characteristics of the GA. We measured the GA produced on two different cable configurations (a ribbon cable and a cable consisting of wires that are twisted together to form a cylindrical bundle) by gradient pulses applied on three orthogonal axes and also characterized the effect of each cable configuration on the GA generated by a multi-slice echo planar imaging sequence, as employed in typical EEG-fMRI studies. The results demonstrate that the cabling that connects the EEG cap to the amplifier can make a significant contribution to the GA recorded during EEG-fMRI studies. In particular, we demonstrate that the GA generated by a ribbon cable is larger than that produced using a twisted cable arrangement and that changes in the GA resulting from variation in the cable position are also greater for the ribbon cable.

  7. Unicompartmental knee arthroplasty MRI: impact of slice-encoding for metal artefact correction MRI on image quality, findings and therapy decision

    Energy Technology Data Exchange (ETDEWEB)

    Agten, Christoph A.; Pfirrmann, Christian W.A.; Sutter, Reto [Balgrist University Hospital, Radiology Department, Zurich (Switzerland); University of Zurich, Faculty of Medicine, Zurich (Switzerland); Grande, Filippo del [Regional Hospital, Radiology, Lugano (Switzerland); Fucentese, Sandro F.; Blatter, Samuel [University of Zurich, Faculty of Medicine, Zurich (Switzerland); Balgrist University Hospital, Orthopedics, Zurich (Switzerland)

    2015-07-15

    To evaluate the impact of slice-encoding for metal artefact correction (SEMAC) on image quality, findings, and therapy decision in patients with unicompartmental knee arthroplasty (UKA). Forty-five painful UKAs were examined at 1.5T-MRI (STIR, proton-density(PD)-weighted sequence, each with SEMAC and high-bandwidth). Artefact size, image quality, anatomic depiction, and clinically relevant findings were compared between SEMAC and high-bandwidth (2 readers). In 30 patients, therapy decision was retrospectively assessed by two orthopaedic surgeons without MRI, with high-bandwidth-MRI, and with SEMAC-MRI. SEMAC reduced mean artefact size for STIR (11.8 cm{sup 2} vs. 37.7 cm{sup 2}) and PD (16.8 cm{sup 2} vs. 18.9 cm{sup 2}), p < 0.0005 for both comparisons. SEMAC showed more blurring than high-bandwidth, p < 0.0005. STIR-SEMAC revealed more bone marrow oedema (29 vs. 18 patients, p = 0.001, 30 vs. 13 patients, p < 0.0005, for reader 1 and 2 respectively). PD-SEMAC was worse in detecting meniscal lesions (6 missed, p = 0.031, 9 missed, p = 0.004, by reader 1 and 2 respectively) than PD-high-bandwidth. Revision-surgery was chosen in 12 and 11 patients without MRI (surgeon 1 and 2), with high-bandwidth-MRI in 15 and 14 patients, and with SEMAC-MRI in 19 and 14 patients. STIR-SEMAC was useful in detecting bone marrow oedema and influenced the orthopaedic surgeons' decisions towards surgery, while PD-SEMAC showed no clinical benefit. (orig.)

  8. Liraglutide, leptin and their combined effects on feeding: additive intake reduction through common intracellular signalling mechanisms.

    Science.gov (United States)

    Kanoski, S E; Ong, Z Y; Fortin, S M; Schlessinger, E S; Grill, H J

    2015-03-01

    To investigate the behavioural and intracellular mechanisms by which the glucagon like peptide-1 (GLP-1) receptor agonist, liraglutide, and leptin in combination enhance the food intake inhibitory and weight loss effects of either treatment alone. We examined the effects of liraglutide (a long-acting GLP-1 analogue) and leptin co-treatment, delivered in low or moderate doses subcutaneously (s.c.) or to the third ventricle, respectively, on cumulative intake, meal patterns and hypothalamic expression of intracellular signalling proteins [phosphorylated signal transducer and activator of transcription-3 (pSTAT3) and protein tyrosine phosphatase-1B (PTP1B)] in lean rats. A low-dose combination of liraglutide (25 µg/kg) and leptin (0.75 µg) additively reduced cumulative food intake and body weight, a result mediated predominantly through a significant reduction in meal frequency that was not present with either drug alone. Liraglutide treatment alone also reduced meal size; an effect not enhanced with leptin co-administration. Moderate doses of liraglutide (75 µg/kg) and leptin (4 µg), examined separately, each reduced meal frequency, cumulative food intake and body weight; only liraglutide reduced meal size. In combination these doses did not further enhance the anorexigenic effects of either treatment alone. Ex vivo immunoblot analysis showed elevated pSTAT3 in the hypothalamic tissue after liraglutide-leptin co-treatment, an effect which was greater than that of leptin treatment alone. In addition, s.c. liraglutide reduced the expression of PTP1B (a negative regulator of leptin receptor signalling), revealing a potential mechanism for the enhanced pSTAT3 response after liraglutide-leptin co-administration. Collectively, these results show novel behavioural and molecular mechanisms underlying the additive reduction in food intake and body weight after liraglutide-leptin combination treatment. © 2014 John Wiley & Sons Ltd.

  9. Application of a Portable XRF Spectrometer for the Non-Invasive analysis of Museum Metal Artefacts

    International Nuclear Information System (INIS)

    Karydas, A.G.

    2007-01-01

    The present paper reviews examples of the application of a portable - in house developed- X RF spectrometer for the analysis of museum metal artefacts in Greece. Specific topics are addressed, in particular, to which extent the qualitative or quantitative X RF analyses reveal important information about the raw materials and manufacture techniques used for gold, silver and bronze alloys in antiquity. The analytical information that it is gained by means of the X RF measurements is further assessed in comparison with the existing archaeometallurgical knowledge

  10. Reducing beam hardening effects and metal artefacts using Medipix3RX: With applications from biomaterial science

    OpenAIRE

    Rajendran, K.; Walsh, M. F.; de Ruiter, N. J. A.; Chernoglazov, A. I.; Panta, R. K.; Butler, A. P. H.; Butler, P. H.; Bell, S. T.; Anderson, N. G.; Woodfield, T. B. F.; Tredinnick, S. J.; Healy, J. L.; Bateman, C. J.; Aamir, R.; Doesburg, R. M. N.

    2013-01-01

    This paper discusses methods for reducing beam hardening effects using spectral data for biomaterial applications. A small-animal spectral scanner operating in the diagnostic energy range was used. We investigate the use of photon-processing features of the Medipix3RX ASIC in reducing beam hardening and associated artefacts. A fully operational charge summing mode was used during the imaging routine. We present spectral data collected for metal alloy samples, its analysis using algebraic 3D r...

  11. The fission-track analysis: An alternative technique for provenance studies of prehistoric obsidian artefacts

    CERN Document Server

    Bellot-Gurlet, L; Dorighel, O; Oddone, M; Poupeau, G; Yegingil, Z

    1999-01-01

    Comparison of fission-track parameters - age and track densities - is an alternative tool for correlating obsidian artefacts with their potential natural sources. This method was applied by different fission-track groups in various regions and results were compared with those obtained using the more popular provenance identification techniques based on chemical composition studies. Hundreds of analyses prove that fission-track dating is a complementary technique which turns out to be very useful, specially when the chemical composition does not fully discriminate different sources. Archaeologically significant results were obtained applying the fission-track analysis in various regions of earth.

  12. The fission-track analysis: An alternative technique for provenance studies of prehistoric obsidian artefacts

    International Nuclear Information System (INIS)

    Bellot-Gurlet, L.; Bigazzi, G.; Dorighel, O.; Oddone, M.; Poupeau, G.; Yegingil, Z.

    1999-01-01

    Comparison of fission-track parameters - age and track densities - is an alternative tool for correlating obsidian artefacts with their potential natural sources. This method was applied by different fission-track groups in various regions and results were compared with those obtained using the more popular provenance identification techniques based on chemical composition studies. Hundreds of analyses prove that fission-track dating is a complementary technique which turns out to be very useful, specially when the chemical composition does not fully discriminate different sources. Archaeologically significant results were obtained applying the fission-track analysis in various regions of earth

  13. How could the Viking Sun compass be used with sunstones before and after sunset? Twilight board as a new interpretation of the Uunartoq artefact fragment.

    Science.gov (United States)

    Bernáth, Balázs; Farkas, Alexandra; Száz, Dénes; Blahó, Miklós; Egri, Adám; Barta, András; Akesson, Susanne; Horváth, Gábor

    2014-06-08

    Vikings routinely crossed the North Atlantic without a magnetic compass and left their mark on lands as far away as Greenland, Newfoundland and Baffin Island. Based on an eleventh-century dial fragment artefact, found at Uunartoq in Greenland, it is widely accepted that they sailed along chosen latitudes using primitive Sun compasses. Such instruments were tested on sea and proved to be efficient hand-held navigation tools, but the dimensions and incisions of the Uunartoq find are far from optimal in this role. On the basis of the sagas mentioning sunstones, incompatible hypotheses were formed for Viking solar navigation procedures and primitive skylight polarimetry with dichroic or birefringent crystals. We describe here a previously unconceived method of navigation based on the Uunartoq artefact functioning as a 'twilight board', which is a combination of a horizon board and a Sun compass optimized for use when the Sun is close to the horizon. We deduced an appropriate solar navigation procedure using a twilight board, a shadow-stick and birefringent crystals, which bring together earlier suggested methods in harmony and provide a true skylight compass function. This could have allowed Vikings to navigate around the clock, to use the artefact dial as a Sun compass during long parts of the day and to use skylight polarization patterns in the twilight period. In field tests, we found that true north could be appointed with such a medieval skylight compass with an error of about ±4° when the artificially occluded Sun had elevation angles between +10° and -8° relative to the horizon. Our interpretation allows us to assign exact dates to the gnomonic lines on the artefact and outlines the schedule of the merchant ships that sustained the Viking colony in Greenland a millennium ago.

  14. Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals

    Directory of Open Access Journals (Sweden)

    Isabel G. Trindade

    2016-09-01

    Full Text Available This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.

  15. Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals.

    Science.gov (United States)

    Trindade, Isabel G; Machado da Silva, José; Miguel, Rui; Pereira, Madalena; Lucas, José; Oliveira, Luís; Valentim, Bruno; Barreto, Jorge; Santos Silva, Manuel

    2016-09-24

    This article addresses the design, development, and evaluation of T-shirt prototypes that embed novel textile sensors for the capture of cardio and respiratory signals. The sensors are connected through textile interconnects to either an embedded custom-designed data acquisition and transmission unit or to snap fastener terminals for connection to external monitoring devices. The performance of the T-shirt prototype is evaluated in terms of signal-to-noise ratio amplitude and signal interference caused by baseline wander and motion artefacts, through laboratory tests with subjects in standing and walking conditions. Performance tests were also conducted in a hospital environment using a T-shirt prototype connected to a commercial three-channel Holter monitoring device. The textile sensors and interconnects were realized with the assistance of an industrial six-needle digital embroidery tool and their resistance to wear addressed with normalized tests of laundering and abrasion. The performance of these wearable systems is discussed, and pathways and methods for their optimization are highlighted.

  16. The characterization of artefacts of cultural heritage significance using physical techniques

    International Nuclear Information System (INIS)

    Creagh, D.C.

    2005-01-01

    All societies attempt to preserve their cultural heritage because it is this that gives them their identity. How artefacts are identified as being of significance to society, and how to preserve these for posterity, depend on the sophistication of those societies, their wealth, and the determination of members of the societies to preserve their past. If conservation or restoration measures are being undertaken complex analytical experiments must be undertaken beforehand to ensure that the work is being undertaken in an appropriate manner. These investigations may employ electromagnetic (IR, VIS, UV, X-ray, γ-ray) or particulate (electron, proton, neutron, and ion beams) radiation. The use of many of these techniques is described in this paper in experiments on Australian Aboriginal bark paintings, a suit of armour belonging to a famous Australian outlaw, and the degradation of colour motion picture film

  17. Dynamic miniature lighting system with low correlated colour temperature and high colour rendering index for museum lighting of fragile artefacts

    DEFF Research Database (Denmark)

    Thorseth, Anders; Corell, Dennis Dan; Poulsen, Peter Behrensdorff

    2013-01-01

    of historical artefacts in display cases at museums and other exhibitions, which can replace 3-5 Watt incandescent light bulbs with a correlated colour temperature (CCT) from 2000 K to 2400 K. The solution decreases the energy consumption by up to 80 %, while maintaining colour rendering indices (Ra) above 90...

  18. Insular artefacts from Viking-Age burials from mid-Norway. A review of contact between Trøndelag and Britain and Ireland

    Directory of Open Access Journals (Sweden)

    Aina Margrethe Heen-Pettersen

    2014-12-01

    Full Text Available This article presents a detailed overview of the Insular artefacts found in Viking-Age burials from the Trøndelag region of mid-Norway, most of which have not previously been published in English. The archaeological evidence indicates that contact between Trøndelag and the British Isles was well established at an early stage of the Viking Age. The main evidence for contact comes from the 9th century, when a number of significant patterns can be discerned. Some local concentrations of Insular goods show the continuing importance of some pre-Viking centres, while other areas suggest co-operation between several neighbouring families in order to equip and provision overseas expeditions. Later, the datable Insular artefacts indicate significant changes in the nature of contact. North Sea trading towards the end of the Viking Age appears to be affected by increasing centralisation of power in Trøndelag during the 10th century.

  19. The social construction of facts and artefacts: or How the sociology of science and the sociology of technology might benefit each other

    NARCIS (Netherlands)

    Pinch, Trevor J.; Bijker, Wiebe E.

    1984-01-01

    The need for an integrated social constructivist approach towards the study of science and technology is outlined. Within such a programme both scientific facts and technological artefacts are to be understood as social constructs. Literature on the sociology of science, the science-technology

  20. Cardiac MOLLI T1 mapping at 3.0 T: comparison of patient-adaptive dual-source RF and conventional RF transmission.

    Science.gov (United States)

    Rasper, Michael; Nadjiri, Jonathan; Sträter, Alexandra S; Settles, Marcus; Laugwitz, Karl-Ludwig; Rummeny, Ernst J; Huber, Armin M

    2017-06-01

    To prospectively compare image quality and myocardial T 1 relaxation times of modified Look-Locker inversion recovery (MOLLI) imaging at 3.0 T (T) acquired with patient-adaptive dual-source (DS) and conventional single-source (SS) radiofrequency (RF) transmission. Pre- and post-contrast MOLLI T 1 mapping using SS and DS was acquired in 27 patients. Patient wise and segment wise analysis of T 1 times was performed. The correlation of DS MOLLI measurements with a reference spin echo sequence was analysed in phantom experiments. DS MOLLI imaging reduced T 1 standard deviation in 14 out of 16 myocardial segments (87.5%). Significant reduction of T 1 variance could be obtained in 7 segments (43.8%). DS significantly reduced myocardial T 1 variance in 16 out of 25 patients (64.0%). With conventional RF transmission, dielectric shading artefacts occurred in six patients causing diagnostic uncertainty. No according artefacts were found on DS images. DS image findings were in accordance with conventional T 1 mapping and late gadolinium enhancement (LGE) imaging. Phantom experiments demonstrated good correlation of myocardial T 1 time between DS MOLLI and spin echo imaging. Dual-source RF transmission enhances myocardial T 1 homogeneity in MOLLI imaging at 3.0 T. The reduction of signal inhomogeneities and artefacts due to dielectric shading is likely to enhance diagnostic confidence.

  1. Correction of motion artefacts and pseudo colour visualization of multispectral light scattering images for optical diagnosis of rheumatoid arthritis

    Science.gov (United States)

    Minet, Olaf; Scheibe, Patrick; Beuthan, Jürgen; Zabarylo, Urszula

    2010-02-01

    State-of-the-art image processing methods offer new possibilities for diagnosing diseases using scattered light. The optical diagnosis of rheumatism is taken as an example to show that the diagnostic sensitivity can be improved using overlapped pseudo-coloured images of different wavelengths, provided that multispectral images are recorded to compensate for any motion related artefacts which occur during examination.

  2. Protection of metal artefacts with the formation of metal-oxalates complexes by Beauveria bassiana.

    Directory of Open Access Journals (Sweden)

    Edith eJoseph

    2012-01-01

    Full Text Available Several fungi present high tolerance to toxic metals and some are able to transform metals into metal-oxalate complexes. In this study, the ability of Beauveria bassiana to produce copper oxalates was evaluated in vitro. Growth performance was tested on various copper-containing media. B. bassiana proved highly resistant to copper, tolerating concentrations of up to 20 g.L-1, and precipitating copper oxalates on all media tested. Chromatographic analyses showed that this species produced oxalic acid as sole metal chelator. The production of metal-oxalates can be used in the restoration and conservation of archaeological and modern metal artefacts. The production of copper-oxalates was confirmed directly using metallic pieces (both archaeological and modern. The conversion of corrosion products into copper oxalates was demonstrated as well. In order to assess whether the capability of B. bassiana to produce metal-oxalates could be applied to other metals, iron and silver were tested as well. Iron appears to be directly sequestered in the wall of the fungal hyphae forming oxalates and probably goethite. However, the formation of a homogeneous layer on the object is not yet optimal. Silver nitrate was extracellularly reduced into nanoparticles of elemental silver by an unknown mechanism. The production of copper oxalates is immediately applicable for the conservation of copper-based artefacts. For iron and silver this is not yet the case. However, the vast ability of B. bassiana to transform toxic metals using different immobilization mechanisms seems to offer considerable possibilities for industrial applications, such as the bioremediation of contaminated soils or the green synthesis of chemicals.

  3. Impact of metal artefacts due to EEG electrodes in brain PET/CT imaging

    International Nuclear Information System (INIS)

    Lemmens, Catherine; Nuyts, Johan; Dupont, Patrick; Montandon, Marie-Louise; Ratib, Osman; Zaidi, Habib

    2008-01-01

    The goal of this study is to investigate the impact of electroencephalogram (EEG) electrodes on the visual quality and quantification of 18 F-FDG PET images in neurological PET/CT examinations. For this purpose, the scans of 20 epilepsy patients with EEG monitoring were used. The CT data were reconstructed with filtered backprojection (FBP) and with a metal artefact reduction (MAR) algorithm. Both data sets were used for CT-based attenuation correction (AC) of the PET data. Also, a calculated AC (CALC) technique was considered. A volume of interest (VOI)-based analysis and a voxel-based quantitative analysis were performed to compare the different AC methods. Images were also evaluated visually by two observers. It was shown with simulations and phantom measurements that from the considered AC methods, the MAR-AC can be used as the reference in this setting. The visual assessment of PET images showed local hot spots outside the brain corresponding to the locations of the electrodes when using FBP-AC. In the brain, no abnormalities were observed. The quantitative analysis showed a very good correlation between PET-FBP-AC and PET-MAR-AC, with a statistically significant positive bias in the PET-FBP-AC images of about 5-7% in most brain voxels. There was also good correlation between PET-CALC-AC and PET-MAR-AC, but in the PET-CALC-AC images, regions with both a significant positive and negative bias were observed. EEG electrodes give rise to local hot spots outside the brain and a positive quantification bias in the brain. However, when diagnosis is made by mere visual assessment, the presence of EEG electrodes does not seem to alter the diagnosis. When quantification is performed, the bias becomes an issue especially when comparing brain images with and without EEG monitoring

  4. Impact of metal artefacts due to EEG electrodes in brain PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lemmens, Catherine; Nuyts, Johan; Dupont, Patrick [Department of Nuclear Medicine and Medical Imaging Center, University Hospital Gasthuisberg and Katholieke Universiteit Leuven, Leuven (Belgium); Montandon, Marie-Louise; Ratib, Osman; Zaidi, Habib [Division of Nuclear Medicine, Geneva University Hospital, CH-1211 Geneva (Switzerland)], E-mail: catherine.lemmens@uz.kuleuven.be

    2008-08-21

    The goal of this study is to investigate the impact of electroencephalogram (EEG) electrodes on the visual quality and quantification of {sup 18}F-FDG PET images in neurological PET/CT examinations. For this purpose, the scans of 20 epilepsy patients with EEG monitoring were used. The CT data were reconstructed with filtered backprojection (FBP) and with a metal artefact reduction (MAR) algorithm. Both data sets were used for CT-based attenuation correction (AC) of the PET data. Also, a calculated AC (CALC) technique was considered. A volume of interest (VOI)-based analysis and a voxel-based quantitative analysis were performed to compare the different AC methods. Images were also evaluated visually by two observers. It was shown with simulations and phantom measurements that from the considered AC methods, the MAR-AC can be used as the reference in this setting. The visual assessment of PET images showed local hot spots outside the brain corresponding to the locations of the electrodes when using FBP-AC. In the brain, no abnormalities were observed. The quantitative analysis showed a very good correlation between PET-FBP-AC and PET-MAR-AC, with a statistically significant positive bias in the PET-FBP-AC images of about 5-7% in most brain voxels. There was also good correlation between PET-CALC-AC and PET-MAR-AC, but in the PET-CALC-AC images, regions with both a significant positive and negative bias were observed. EEG electrodes give rise to local hot spots outside the brain and a positive quantification bias in the brain. However, when diagnosis is made by mere visual assessment, the presence of EEG electrodes does not seem to alter the diagnosis. When quantification is performed, the bias becomes an issue especially when comparing brain images with and without EEG monitoring.

  5. A micro-invasive approach using INAA for new insights into Palaeolithic flint archaeological artefacts

    International Nuclear Information System (INIS)

    Prudencio, M.I.; Dias, M.I.; Marques, R.; Roldan, C.; Aleix Eixea; Villaverde, V.

    2016-01-01

    Instrumental neutron activation analysis of small flakes from the same flint fragment of archaeological artefacts from Palaeolithic sites ('Abrigo de la Quebrada', 'Cova de les Cendres' and 'Cova Negra'), and eological sour ces (Chelva, Valencia, and Alcoi, Alicante) from the eastern Spain, was performed. The chemical contents of 27 elements were obtained. Ga, Ce, Nd, Yb, Zr and Hf were discarded due to high variations within the same fragment. The identification of chemical fingerprints within heterogeneous flint fragments was able to differentiate flint types and variants ('Domeno' and 'Serreta'), contributing to provenance and human mobility in ancient times. (author)

  6. Quantitative assessment of chemical artefacts produced by propionylation of histones prior to mass spectrometry analysis.

    Science.gov (United States)

    Soldi, Monica; Cuomo, Alessandro; Bonaldi, Tiziana

    2016-07-01

    Histone PTMs play a crucial role in regulating chromatin structure and function, with impact on gene expression. MS is nowadays widely applied to study histone PTMs systematically. Because histones are rich in arginine and lysine, classical shot-gun approaches based on trypsin digestion are typically not employed for histone modifications mapping. Instead, different protocols of chemical derivatization of lysines in combination with trypsin have been implemented to obtain "Arg-C like" digestion products that are more suitable for LC-MS/MS analysis. Although widespread, these strategies have been recently described to cause various side reactions that result in chemical modifications prone to be misinterpreted as native histone marks. These artefacts can also interfere with the quantification process, causing errors in histone PTMs profiling. The work of Paternoster V. et al. is a quantitative assessment of methyl-esterification and other side reactions occurring on histones after chemical derivatization of lysines with propionic anhydride [Proteomics 2016, 16, 2059-2063]. The authors estimate the effect of different solvents, incubation times, and pH on the extent of these side reactions. The results collected indicate that the replacement of methanol with isopropanol or ACN not only blocks methyl-esterification, but also significantly reduces other undesired unspecific reactions. Carefully titrating the pH after propionic anhydride addition is another way to keep methyl-esterification under control. Overall, the authors describe a set of experimental conditions that allow reducing the generation of various artefacts during histone propionylation. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. The effects of LIGO detector noise on a 15-dimensional Markov-chain Monte Carlo analysis of gravitational-wave signals

    International Nuclear Information System (INIS)

    Raymond, V; Mandel, I; Kalogera, V; Van der Sluys, M V; Roever, C; Christensen, N

    2010-01-01

    Gravitational-wave signals from inspirals of binary compact objects (black holes and neutron stars) are primary targets of the ongoing searches by ground-based gravitational-wave (GW) interferometers (LIGO, Virgo and GEO-600). We present parameter estimation results from our Markov-chain Monte Carlo code SPINspiral on signals from binaries with precessing spins. Two data sets are created by injecting simulated GW signals either into synthetic Gaussian noise or into LIGO detector data. We compute the 15-dimensional probability-density functions (PDFs) for both data sets, as well as for a data set containing LIGO data with a known, loud artefact ('glitch'). We show that the analysis of the signal in detector noise yields accuracies similar to those obtained using simulated Gaussian noise. We also find that while the Markov chains from the glitch do not converge, the PDFs would look consistent with a GW signal present in the data. While our parameter estimation results are encouraging, further investigations into how to differentiate an actual GW signal from noise are necessary.

  8. Apneic oxygenation for elimination of respiratory motion artefact in an intubated patient undergoing helical chest computed tomography angiography.

    Directory of Open Access Journals (Sweden)

    Ioannis Pneumatikos

    2008-10-01

    Full Text Available Respiratory motion artifact in intubated and mechanically ventilated patients often reduces the quality of helical computed tomography pulmonary angiography (CTPA. Apneic oxygenation is a well established intra-operative technique that allows adequate oxygenation for short periods (up to 10 min in sedated and paralyzed patients. We describe the use of the apneic oxygenation for elimination of respiratory motion artefact in an intubated patient undergoing helical chest computed tomography angiography.

  9. Re-Normalization Method of Doppler Lidar Signal for Error Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Park, Nakgyu; Baik, Sunghoon; Park, Seungkyu; Kim, Donglyul [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Dukhyeon [Hanbat National Univ., Daejeon (Korea, Republic of)

    2014-05-15

    In this paper, we presented a re-normalization method for the fluctuations of Doppler signals from the various noises mainly due to the frequency locking error for a Doppler lidar system. For the Doppler lidar system, we used an injection-seeded pulsed Nd:YAG laser as the transmitter and an iodine filter as the Doppler frequency discriminator. For the Doppler frequency shift measurement, the transmission ratio using the injection-seeded laser is locked to stabilize the frequency. If the frequency locking system is not perfect, the Doppler signal has some error due to the frequency locking error. The re-normalization process of the Doppler signals was performed to reduce this error using an additional laser beam to an Iodine cell. We confirmed that the renormalized Doppler signal shows the stable experimental data much more than that of the averaged Doppler signal using our calibration method, the reduced standard deviation was 4.838 Χ 10{sup -3}.

  10. Speckle noise reduction technique for Lidar echo signal based on self-adaptive pulse-matching independent component analysis

    Science.gov (United States)

    Xu, Fan; Wang, Jiaxing; Zhu, Daiyin; Tu, Qi

    2018-04-01

    Speckle noise has always been a particularly tricky problem in improving the ranging capability and accuracy of Lidar system especially in harsh environment. Currently, effective speckle de-noising techniques are extremely scarce and should be further developed. In this study, a speckle noise reduction technique has been proposed based on independent component analysis (ICA). Since normally few changes happen in the shape of laser pulse itself, the authors employed the laser source as a reference pulse and executed the ICA decomposition to find the optimal matching position. In order to achieve the self-adaptability of algorithm, local Mean Square Error (MSE) has been defined as an appropriate criterion for investigating the iteration results. The obtained experimental results demonstrated that the self-adaptive pulse-matching ICA (PM-ICA) method could effectively decrease the speckle noise and recover the useful Lidar echo signal component with high quality. Especially, the proposed method achieves 4 dB more improvement of signal-to-noise ratio (SNR) than a traditional homomorphic wavelet method.

  11. Efficient algorithm for baseline wander and powerline noise removal from ECG signals based on discrete Fourier series.

    Science.gov (United States)

    Bahaz, Mohamed; Benzid, Redha

    2018-03-01

    Electrocardiogram (ECG) signals are often contaminated with artefacts and noises which can lead to incorrect diagnosis when they are visually inspected by cardiologists. In this paper, the well-known discrete Fourier series (DFS) is re-explored and an efficient DFS-based method is proposed to reduce contribution of both baseline wander (BW) and powerline interference (PLI) noises in ECG records. In the first step, the determination of the exact number of low frequency harmonics contributing in BW is achieved. Next, the baseline drift is estimated by the sum of all associated Fourier sinusoids components. Then, the baseline shift is discarded efficiently by a subtraction of its approximated version from the original biased ECG signal. Concerning the PLI, the subtraction of the contributing harmonics calculated in the same manner reduces efficiently such type of noise. In addition of visual quality results, the proposed algorithm shows superior performance in terms of higher signal-to-noise ratio and smaller mean square error when faced to the DCT-based algorithm.

  12. Development of Focused Ion Beam technique for high speed steel 3D-SEM artefact fabrication

    DEFF Research Database (Denmark)

    Carli, Lorenzo; MacDonald, A. Nicole; De Chiffre, Leonardo

    2009-01-01

    The work describes preliminary manufacture by grinding, followed by machining on a Focused Ion Beam (FIB), of a high speed steel step artefact for 3D-SEM calibration. The FIB is coupled with a SEM in the so called dual beam instrument. The milling capabilities of FIB were checked from a qualitative...... point of view, using the dual beam SEM imaging, and quantitatively using a reference stylus instrument, to establish traceability. A triangular section having a depth of about 10 μm was machined, where the 50 μm curvature radius due to grinding was reduced to about 2 μm by FIB milling...

  13. Fairly direct hit. Advances in imaging of shotgun projectiles in MRI

    Energy Technology Data Exchange (ETDEWEB)

    Eggert, Sebastian [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); University of Zurich, Institute of Forensic Medicine, Zurich (Switzerland); Kubik-Huch, Rahel A.; Peters, Alexander [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); Klarhoefer, Markus [Siemens Healthcare, Zurich (Switzerland); Bolliger, Stephan A.; Thali, Michael J. [University of Zurich, Institute of Forensic Medicine, Zurich (Switzerland); Anderson, Suzanne [Kantonsspital Baden AG, Department of Radiology, Baden (Switzerland); University of Notre Dame Australia, Radiology, Sydney School of Medicine, Sydney, NSW (Australia); Froehlich, Johannes M. [Federal Institute of Technology, Pharmaceutical Sciences, Zurich (Switzerland)

    2015-09-15

    To investigate the magnetic properties of different types of projectiles and qualify the metal artefact reduction technique for diagnostic and/or forensic MRI. Ten different projectiles embedded in ordnance gelatine blocks underwent an in vitro 1.5-T MR study with seven sequences including a recently developed metal artefact reduction sequence (Advanced WARP) combining VAT (view-angle-tilting) and SEMAC (slice-encoding metal-artefact-correction). Resulting image quality (five-point scale: 1=best; 5=worst) was scored. Quantifiable magnetic characteristics were correlated with qualitative rating of the MR sequences and torque dislodgment. Metal artefact reduction sequence (median: 2.5) significantly (p < 0.001) improves depiction of projectiles in comparison to all other MR pulse sequences (median: 4.75). Images from diamagnetic composed bullets (median: 2) are much less disturbed compared to magnetic attracted ones (median: 5). Correlation (0.623) between deflection angle measurement (ferromagnetic mean 84.2 ; paramagnetic 62 ; diamagnetic mean 0 ) and median qualitative image quality was highly significant (p = 0.027). Torque dislodgement was distinct for elongated magnetic attracted projectiles. Significant improvement of MR imaging of projectiles using metal artefact reduction techniques has important implications for diagnostic/forensic work-up. The correlations between magnetic attraction force, deflection-angle results and image properties demonstrate that the MR safety of projectiles can be estimated with one of these methods. (orig.)

  14. Fairly direct hit. Advances in imaging of shotgun projectiles in MRI

    International Nuclear Information System (INIS)

    Eggert, Sebastian; Kubik-Huch, Rahel A.; Peters, Alexander; Klarhoefer, Markus; Bolliger, Stephan A.; Thali, Michael J.; Anderson, Suzanne; Froehlich, Johannes M.

    2015-01-01

    To investigate the magnetic properties of different types of projectiles and qualify the metal artefact reduction technique for diagnostic and/or forensic MRI. Ten different projectiles embedded in ordnance gelatine blocks underwent an in vitro 1.5-T MR study with seven sequences including a recently developed metal artefact reduction sequence (Advanced WARP) combining VAT (view-angle-tilting) and SEMAC (slice-encoding metal-artefact-correction). Resulting image quality (five-point scale: 1=best; 5=worst) was scored. Quantifiable magnetic characteristics were correlated with qualitative rating of the MR sequences and torque dislodgment. Metal artefact reduction sequence (median: 2.5) significantly (p < 0.001) improves depiction of projectiles in comparison to all other MR pulse sequences (median: 4.75). Images from diamagnetic composed bullets (median: 2) are much less disturbed compared to magnetic attracted ones (median: 5). Correlation (0.623) between deflection angle measurement (ferromagnetic mean 84.2 ; paramagnetic 62 ; diamagnetic mean 0 ) and median qualitative image quality was highly significant (p = 0.027). Torque dislodgement was distinct for elongated magnetic attracted projectiles. Significant improvement of MR imaging of projectiles using metal artefact reduction techniques has important implications for diagnostic/forensic work-up. The correlations between magnetic attraction force, deflection-angle results and image properties demonstrate that the MR safety of projectiles can be estimated with one of these methods. (orig.)

  15. Comparative assessment of knee joint models used in multi-body kinematics optimisation for soft tissue artefact compensation.

    Science.gov (United States)

    Richard, Vincent; Cappozzo, Aurelio; Dumas, Raphaël

    2017-09-06

    Estimating joint kinematics from skin-marker trajectories recorded using stereophotogrammetry is complicated by soft tissue artefact (STA), an inexorable source of error. One solution is to use a bone pose estimator based on multi-body kinematics optimisation (MKO) embedding joint constraints to compensate for STA. However, there is some debate over the effectiveness of this method. The present study aimed to quantitatively assess the degree of agreement between reference (i.e., artefact-free) knee joint kinematics and the same kinematics estimated using MKO embedding six different knee joint models. The following motor tasks were assessed: level walking, hopping, cutting, running, sit-to-stand, and step-up. Reference knee kinematics was taken from pin-marker or biplane fluoroscopic data acquired concurrently with skin-marker data, made available by the respective authors. For each motor task, Bland-Altman analysis revealed that the performance of MKO varied according to the joint model used, with a wide discrepancy in results across degrees of freedom (DoFs), models and motor tasks (with a bias between -10.2° and 13.2° and between -10.2mm and 7.2mm, and with a confidence interval up to ±14.8° and ±11.1mm, for rotation and displacement, respectively). It can be concluded that, while MKO might occasionally improve kinematics estimation, as implemented to date it does not represent a reliable solution to the STA issue. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Advanced defect detection algorithm using clustering in ultrasonic NDE

    Science.gov (United States)

    Gongzhang, Rui; Gachagan, Anthony

    2016-02-01

    A range of materials used in industry exhibit scattering properties which limits ultrasonic NDE. Many algorithms have been proposed to enhance defect detection ability, such as the well-known Split Spectrum Processing (SSP) technique. Scattering noise usually cannot be fully removed and the remaining noise can be easily confused with real feature signals, hence becoming artefacts during the image interpretation stage. This paper presents an advanced algorithm to further reduce the influence of artefacts remaining in A-scan data after processing using a conventional defect detection algorithm. The raw A-scan data can be acquired from either traditional single transducer or phased array configurations. The proposed algorithm uses the concept of unsupervised machine learning to cluster segmental defect signals from pre-processed A-scans into different classes. The distinction and similarity between each class and the ensemble of randomly selected noise segments can be observed by applying a classification algorithm. Each class will then be labelled as `legitimate reflector' or `artefacts' based on this observation and the expected probability of defection (PoD) and probability of false alarm (PFA) determined. To facilitate data collection and validate the proposed algorithm, a 5MHz linear array transducer is used to collect A-scans from both austenitic steel and Inconel samples. Each pulse-echo A-scan is pre-processed using SSP and the subsequent application of the proposed clustering algorithm has provided an additional reduction to PFA while maintaining PoD for both samples compared with SSP results alone.

  17. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    Energy Technology Data Exchange (ETDEWEB)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J. [Institut Curie, Imaging Department, Paris (France); Pavia, Y.; Pierrat, N. [Institut Curie, Medical Physics Department, Paris (France)

    2014-01-15

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  18. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT

    International Nuclear Information System (INIS)

    Gay, F.; Lasalle, S.; Neuenschwander, S.; Brisse, H.J.; Pavia, Y.; Pierrat, N.

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. (orig.)

  19. Iron corrosion in an anoxic soil: Comparison between thermodynamic modelling and ferrous archaeological artefacts characterised along with the local in situ geochemical conditions

    Energy Technology Data Exchange (ETDEWEB)

    Saheb, M.; Neff, D.; Michelin, A.; Dillmann, P. [CEA Saclay, CNRS, LAPA SIS2M, UMR3299, 91 - Gif-sur-Yvette (France); Saheb, M. [ANDRA, F-92298 Chatenay Malabry (France); Descostes, M. [CEA Saclay, DEN DANS DPC SECR, Lab Radionuclides Migrat Measurements and Modelling, 91 - Gif-sur-Yvette (France); Descostes, M. [Univ Evry, CEA, CNRS, UMR 8587, Evry (France); Dillmann, P. [CNRS, Inst Rech Archeomat, UMR 5060, F-75700 Paris (France)

    2010-07-01

    This article is part of an ongoing study on the long-term corrosion behaviour of ferrous archaeological artefacts. The aim of this study is to correlate the corrosion products formed on ancient artefacts in an anoxic medium to the environmental data using thermodynamic modelling. For this purpose, measurement campaigns have been conducted on the archaeological site of Glinet (16. century, High Normandy (Seine-Maritime), France) where the evolution of the pore water chemistry has been recorded for a period of one year. Three evolution steps have been distinguished after the oxidizing perturbation which was induced by the piezometers installation. The first step was related to an oxidizing environment in which pore water was in equilibrium with a Fe(III) precipitated phase: ferri-hydrite (FeOOH center dot 0.4 H{sub 2}O). The second step was considered as an intermediate step and Fe speciation had evolved; equilibrium was achieved between ferri-hydrite and a Fe(II) carbonate phase: siderite (Fe(II)CO{sub 3}). The last step of the evolution was related to a reducing stage where pore water was in equilibrium with magnetite (Fe(II, III){sub 3}O{sub 4}) and with chukanovite (Fe(II){sub 2}(OH){sub 2}CO{sub 3}). As these phases were present in the corrosion layers formed on the archaeological samples, it is possible to conclude that the thermodynamic approach was helpful in developing a better understanding of the effect of geochemical conditions on the composition and mineralogy of the corrosion products formed on archaeological artefacts. This work could be used as a reference for further corrosion studies, especially on long-term corrosion processes applied to nuclear waste disposal. (authors)

  20. Perfusion MRI of brain tumours: a comparative study of pseudo-continuous arterial spin labelling and dynamic susceptibility contrast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Jaernum, Hanna; Steffensen, Elena G.; Simonsen, Carsten Wiberg; Jensen, Finn Taagehoej [Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Knutsson, Linda [Lund University, Department of Medical Radiation Physics, Lund (Sweden); Fruend, Ernst-Torben [Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); GE Healthcare - Applied Science Lab Europe, Aalborg (Denmark); Lundbye-Christensen, Soeren [Aalborg Hospital/Aarhus University Hospital, Department of Cardiology, Center for Cardiovascular Research, Aalborg (Denmark); Shankaranarayanan, Ajit [Global Applied Science Lab, GE Healthcare, Menlo Park, CA (United States); Alsop, David C. [Beth Israel Deaconess Medical Center and Harvard Medical School, Boston, MA (United States); Larsson, Elna-Marie [Aalborg Hospital/Aarhus University Hospital, Department of Radiology, Aalborg (Denmark); Uppsala University Hospital, Department of Radiology, Uppsala (Sweden)

    2010-04-15

    The purpose of this study was to compare the non-invasive 3D pseudo-continuous arterial spin labelling (PC ASL) technique with the clinically established dynamic susceptibility contrast perfusion magnetic resonance imaging (DSC-MRI) for evaluation of brain tumours. A prospective study of 28 patients with contrast-enhancing brain tumours was performed at 3 T using DSC-MRI and PC ASL with whole-brain coverage. The visual qualitative evaluation of signal enhancement in tumour was scored from 0 to 3 (0 = no signal enhancement compared with white matter, 3 = pronounced signal enhancement with equal or higher signal intensity than in grey matter/basal ganglia). The extent of susceptibility artefacts in the tumour was scored from 0 to 2 (0 = no susceptibility artefacts and 2 = extensive susceptibility artefacts (maximum diameter > 2 cm)). A quantitative analysis was performed with normalised tumour blood flow values (ASL nTBF, DSC nTBF): mean value for region of interest (ROI) in an area with maximum signal enhancement/the mean value for ROIs in cerebellum. There was no difference in total visual score for signal enhancement between PC ASL and DSC relative cerebral blood flow (p = 0.12). ASL had a lower susceptibility-artefact score than DSC-MRI (p = 0.03). There was good correlation between DSC nTBF and ASL nTBF values with a correlation coefficient of 0.82. PC ASL is an alternative to DSC-MRI for the evaluation of perfusion in brain tumours. The method has fewer susceptibility artefacts than DSC-MRI and can be used in patients with renal failure because no contrast injection is needed. (orig.)

  1. The Fundamentals Regarding the Usage of the Concept of Interface for the Modeling of the Software Artefacts

    Directory of Open Access Journals (Sweden)

    Dorin Bocu

    2016-03-01

    Full Text Available This paper presents the conceptual foundations of a software system’s solution modelling activity, which is formally based on two essential concepts: the artefact and the interface. This  modelling activity envisions  two  objectives: the  explicit emphasis on the  interfaces’ importance in the software engineering, and the preparation of the  framework inside which  the  loop structure-behaviour can be formalized considering the inherent benefits for the  modelling activity in  general, and  for  the  modelling activity automation in particular.

  2. Television picture signal processing

    NARCIS (Netherlands)

    1998-01-01

    Field or frame memories are often used in television receivers for video signal processing functions, such as noise reduction and/or flicker reduction. Television receivers also have graphic features such as teletext, menu-driven control systems, multilingual subtitling, an electronic TV-Guide, etc.

  3. Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT.

    Science.gov (United States)

    Gay, F; Pavia, Y; Pierrat, N; Lasalle, S; Neuenschwander, S; Brisse, H J

    2014-01-01

    To assess the benefit and limits of iterative reconstruction of paediatric chest and abdominal computed tomography (CT). The study compared adaptive statistical iterative reconstruction (ASIR) with filtered back projection (FBP) on 64-channel MDCT. A phantom study was first performed using variable tube potential, tube current and ASIR settings. The assessed image quality indices were the signal-to-noise ratio (SNR), the noise power spectrum, low contrast detectability (LCD) and spatial resolution. A clinical retrospective study of 26 children (M:F = 14/12, mean age: 4 years, range: 1-9 years) was secondarily performed allowing comparison of 18 chest and 14 abdominal CT pairs, one with a routine CT dose and FBP reconstruction, and the other with 30 % lower dose and 40 % ASIR reconstruction. Two radiologists independently compared the images for overall image quality, noise, sharpness and artefacts, and measured image noise. The phantom study demonstrated a significant increase in SNR without impairment of the LCD or spatial resolution, except for tube current values below 30-50 mA. On clinical images, no significant difference was observed between FBP and reduced dose ASIR images. Iterative reconstruction allows at least 30 % dose reduction in paediatric chest and abdominal CT, without impairment of image quality. • Iterative reconstruction helps lower radiation exposure levels in children undergoing CT. • Adaptive statistical iterative reconstruction (ASIR) significantly increases SNR without impairing spatial resolution. • For abdomen and chest CT, ASIR allows at least a 30 % dose reduction.

  4. Magnetic resonance imaging signal reduction may precede volume loss in the pituitary gland of transfusion-dependent beta-thalassemic patients

    Energy Technology Data Exchange (ETDEWEB)

    Hekmatnia, Ali; Rahmani, Ali Asghar; Adibi, Atoosa (Image Processing and Signal Research Center, Dept. of Radiology, Isfahan Univ. of Medical Sciences, Isfahan (Iran)); Radmard, Amir Reza (Dept. of Radiology, Shariati Hospital, Tehran Univ. of Medical Sciences, Tehran (Iran)); Khademi, Hooman (Shariati Hospital, Tehran Univ. of Medical Sciences, Tehran (Iran)), e-mail: radmard@ams.ac.ir

    2010-01-15

    Background: Pituitary iron overload in patients with transfusion-dependent beta-thalassemia may lead to delayed puberty. Magnetic resonance imaging (MRI) has the potential to estimate tissue iron concentration by detecting its paramagnetic effect and hypophyseal damage by measuring its dimensions indirectly. Purpose: To investigate the association of pituitary MRI findings and pubertal status in thalassemic patients as well as to demonstrate any priority in appearance of them. Material and Methods: Twenty-seven beta-thalassemic patients, aged 15-25 years, were divided into 13 with (group A) and 14 without hypogonadism (group B), matched by age, gender, duration of transfusion, and chelation therapy. Thirty-eight age- and sex-adjusted healthy control individuals were also included (group C). All participants underwent pituitary MRI using a 1.5T unit. Pituitary-to-fat signal intensity ratios (SIR) were calculated from coronal T2-weighted images. Estimated pituitary volumes were measured using pituitary height, width, and length on T1-weighted images. Results: The mean values of pituitary-to-fat SIRs were significantly lower in group A as compared with group B (P <0.001), and likewise group B had statistically lower values than group C (P=0.03). The pituitary height and volume were significantly decreased in group A compared to group B (P = 0.006 and P = 0.002, respectively), while these differences did not demonstrate statistically significance between groups B and C. Conclusion: Pituitary MRI findings such as signal intensity reduction and decrease in volume can be useful markers in estimating pituitary dysfunction in beta-thalassemic patients. Compared to healthy controls, lower values of pituitary-to-fat SIRs in thalassemic patients experiencing normal puberty, without marked decrease in volume, indicate that signal reduction may precede volume loss and could be expected first on MRI

  5. A phantom-based evaluation of three commercially available patient organ shields for computed tomography X-ray examinations in diagnostic radiology

    International Nuclear Information System (INIS)

    Huggett, J.; Mukonoweshuro, W.; Loader, R.

    2013-01-01

    Three commercially available in-plane patient organ shields (barium eye, bismuth eye and bismuth breast) for computed tomography (CT) examinations were evaluated to determine their effectiveness for dose reduction. Absorbed doses were measured using metal oxide semiconductor field effect transistor dosemeters fastened to a Kyoto CT Torso phantom. Resultant images were visually compared with those minus shielding by an experienced radiologist. Approximate dose reductions of 21, 38 and 50 % were achieved by the barium eye, bismuth eye and bismuth breast shields, respectively, at a cost of increased image noise and streak artefacts. Shielded images produced varied levels of image artefact, particularly those resulting from the eye shields. Measured dose reductions were not consistent with the potential dose savings stated by the manufacturers of the shields. When evaluating the breast shield, similar dose reduction was achieved without shield-induced artefact by simply reducing the X-ray tube current. (authors)

  6. Quality assurance in MRI breast screening: comparing signal-to-noise ratio in dynamic contrast-enhanced imaging protocols

    Science.gov (United States)

    Kousi, Evanthia; Borri, Marco; Dean, Jamie; Panek, Rafal; Scurr, Erica; Leach, Martin O.; Schmidt, Maria A.

    2016-01-01

    MRI has been extensively used in breast cancer staging, management and high risk screening. Detection sensitivity is paramount in breast screening, but variations of signal-to-noise ratio (SNR) as a function of position are often overlooked. We propose and demonstrate practical methods to assess spatial SNR variations in dynamic contrast-enhanced (DCE) breast examinations and apply those methods to different protocols and systems. Four different protocols in three different MRI systems (1.5 and 3.0 T) with receiver coils of different design were employed on oil-filled test objects with and without uniformity filters. Twenty 3D datasets were acquired with each protocol; each dataset was acquired in under 60 s, thus complying with current breast DCE guidelines. In addition to the standard SNR calculated on a pixel-by-pixel basis, we propose other regional indices considering the mean and standard deviation of the signal over a small sub-region centred on each pixel. These regional indices include effects of the spatial variation of coil sensitivity and other structured artefacts. The proposed regional SNR indices demonstrate spatial variations in SNR as well as the presence of artefacts and sensitivity variations, which are otherwise difficult to quantify and might be overlooked in a clinical setting. Spatial variations in SNR depend on protocol choice and hardware characteristics. The use of uniformity filters was shown to lead to a rise of SNR values, altering the noise distribution. Correlation between noise in adjacent pixels was associated with data truncation along the phase encoding direction. Methods to characterise spatial SNR variations using regional information were demonstrated, with implications for quality assurance in breast screening and multi-centre trials.

  7. Synchronizing the transcranial magnetic pulse with electroencephalographic recordings effectively reduces inter-trial variability of the pulse artefact

    DEFF Research Database (Denmark)

    Tomasevic, Leo; Takemi, Mitsuaki; Siebner, Hartwig Roman

    2017-01-01

    delivered monophasic and biphasic TMS to a melon as head phantom and to four healthy participants and recorded the pulse artefact at 5 kHz with a TMS-compatible EEG system. Pulse delivery was either synchronized or non-synchronized to the clock of the EEG recording system. The effects of synchronization...... were tested at 10 and 20 kHz using the head phantom. We also tested the effect of a soft sheet placed between the stimulation coil and recording electrodes in both human and melon. RESULTS & CONCLUSION: Synchronizing TMS and data acquisition markedly reduced trial-to-trial variability of the pulse...

  8. Multi-slice ultrasound image calibration of an intelligent skin-marker for soft tissue artefact compensation.

    Science.gov (United States)

    Masum, M A; Pickering, M R; Lambert, A J; Scarvell, J M; Smith, P N

    2017-09-06

    In this paper, a novel multi-slice ultrasound (US) image calibration of an intelligent skin-marker used for soft tissue artefact compensation is proposed to align and orient image slices in an exact H-shaped pattern. Multi-slice calibration is complex, however, in the proposed method, a phantom based visual alignment followed by transform parameters estimation greatly reduces the complexity and provides sufficient accuracy. In this approach, the Hough Transform (HT) is used to further enhance the image features which originate from the image feature enhancing elements integrated into the physical phantom model, thus reducing feature detection uncertainty. In this framework, slice by slice image alignment and calibration are carried out and this provides manual ease and convenience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Noise-aware dictionary-learning-based sparse representation framework for detection and removal of single and combined noises from ECG signal.

    Science.gov (United States)

    Satija, Udit; Ramkumar, Barathram; Sabarimalai Manikandan, M

    2017-02-01

    Automatic electrocardiogram (ECG) signal enhancement has become a crucial pre-processing step in most ECG signal analysis applications. In this Letter, the authors propose an automated noise-aware dictionary learning-based generalised ECG signal enhancement framework which can automatically learn the dictionaries based on the ECG noise type for effective representation of ECG signal and noises, and can reduce the computational load of sparse representation-based ECG enhancement system. The proposed framework consists of noise detection and identification, noise-aware dictionary learning, sparse signal decomposition and reconstruction. The noise detection and identification is performed based on the moving average filter, first-order difference, and temporal features such as number of turning points, maximum absolute amplitude, zerocrossings, and autocorrelation features. The representation dictionary is learned based on the type of noise identified in the previous stage. The proposed framework is evaluated using noise-free and noisy ECG signals. Results demonstrate that the proposed method can significantly reduce computational load as compared with conventional dictionary learning-based ECG denoising approaches. Further, comparative results show that the method outperforms existing methods in automatically removing noises such as baseline wanders, power-line interference, muscle artefacts and their combinations without distorting the morphological content of local waves of ECG signal.

  10. Goldtraces on wedge-shaped artefacts from late neolithic of south Scandinavia analysed by proton induced x-ray emission spectroscopy

    International Nuclear Information System (INIS)

    Ahlberg, M.; Akselsson, R.; Forkman, B.; Rausing, G.

    1975-01-01

    Visible coloured traces on the surface of two selected wedge-shaped artefacts (pendants) of slate from the late Neolithic of South Scandinavia was analysed by means of proton-induced x-ray emission spectroscopy (PIXE). PIXE is shown to be a feasible tool in investigating surface layers of archeological significance. Three different gold-silver alloys was found on the two pendants. The results indicate that we shall have to reconsider the general accepted theories on the economic basis of the early Bronze Age in the area. (author)

  11. Efficacy of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) for shoulder magnetic resonance (MR) imaging

    Energy Technology Data Exchange (ETDEWEB)

    Nagatomo, Kazuya, E-mail: nkgzmyn.1103@gmail.com [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Yabuuchi, Hidetake, E-mail: h-yabu@med.kyushu-u.ac.jp [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Yamasaki, Yuzo, E-mail: yyama@radiol.med.kyushu-u.ac.jp [Department of Clinical Radiology, Graduate of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Narita, Hiroshi, E-mail: hiroshi.narita.ty@hitachi.com [Hitachi Medical Corporation, 3-26-29 Hakataekimae, Hakata-ku, Fukuoka 812-0011 (Japan); Kumazawa, Seiji, E-mail: s_kmzw@hs.med.kyushu-u.ac.jp [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Kojima, Tsukasa, E-mail: k.tsukasa.0910@gmail.com [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Sakai, Noriyuki, E-mail: noriyuki.sakai0602@gmail.com [Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582 (Japan); Masaki, Masahumi, E-mail: m-masaki@kimura-hosp.or.jp [Department of Radiology, Kimura Hospital, 2-13-19 Chiyo, Hakata-ku, Fukuoka 812-0044 (Japan); Kimura, Hiroshi, E-mail: h-kimura@kimura-hosp.or.jp [Department of Surgery, Kimura Hospital, 2-13-19 Chiyo, Hakata-ku, Fukuoka 812-0044 (Japan)

    2016-10-15

    Objectives: To elucidate the utility of PROPELLER for motion artefact reduction on shoulder MRI and to examine the influence of streak artefacts on diagnosis of clinical images. Methods: 15 healthy volunteers and 48 patients underwent shoulder MRI with/without PROPELLER (coronal oblique proton density-fast spin echo [PD-FSE], sagittal oblique T2-FSE). In a volunteer study, all sequences were performed in both static and exercise-loaded conditions. Two radiologists graded artefacts and delineation of various anatomical structures in the volunteer study and motion and streak artefacts in the clinical study. Mean scores were compared between sequences with/without PROPELLER. In the clinical study, mean scores of motion artefacts were compared with mean scores of streak artefacts. Wilcoxon signed-rank test was used for all comparisons. Results: In both studies, PROPELLER significantly reduced motion artefacts (P < 0.05). In the volunteer study, it significantly improved delineations in sagittal oblique images in the exercise-loaded condition (P < 0.05). In the clinical study, streak artefacts appeared dominantly on images with PROPELLER (P < 0.05), but influenced diagnosis to a lesser extent than motion artefacts. Conclusion: PROPELLER can reduce motion artefacts in shoulder MRI. While it does cause streak artefacts, it affects diagnosis to a lesser extent.

  12. Metal artefacts severely hamper magnetic resonance imaging of the rotator cuff tendons after rotator cuff repair with titanium suture anchors.

    Science.gov (United States)

    Schröder, Femke F; Huis In't Veld, Rianne; den Otter, Lydia A; van Raak, Sjoerd M; Ten Haken, Bennie; Vochteloo, Anne J H

    2018-04-01

    The rate of retear after rotator cuff surgery is 17%. Magnetic resonance imaging (MRI) scans are used for confirmative diagnosis of retear. However, because of the presence of titanium suture anchors, metal artefacts on the MRI are common. The present study evaluated the diagnostic value of MRI after rotator cuff tendon surgery with respect to assessing the integrity as well as the degeneration and atrophy of the rotator cuff tendons when titanium anchors are in place. Twenty patients who underwent revision surgery of the rotator cuff as a result of a clinically suspected retear between 2013 and 2015 were included. The MRI scans of these patients were retrospectively analyzed by four specialized shoulder surgeons and compared with intra-operative findings (gold standard). Sensitivity and interobserver agreement among the surgeons in assessing retears as well as the Goutallier and Warner classification were examined. In 36% (range 15% to 50%) of the pre-operative MRI scans, the observers could not review the rotator cuff tendons. When the rotator cuff tendons were assessable, a diagnostic accuracy with a mean sensitivity of 0.84 (0.70 to 1.0) across the surgeons was found, with poor interobserver agreement (kappa = 0.12). Metal artefacts prevented accurate diagnosis from MRI scans of rotator cuff retear in 36% of the patients studied.

  13. Cell respiration under hypoxia: facts and artefacts in mitochondrial oxygen kinetics.

    Science.gov (United States)

    Scandurra, Francesca M; Gnaiger, Erich

    2010-01-01

    When oxygen supply to tissues is limiting, mitochondrial respiration and ATP production are compromised. To assess the bioenergetic consequences under normoxia and hypoxia, quantitative evaluation of mitochondrial oxygen kinetics is required. Using high-resolution respirometry, the "apparent K (m)" for oxygen or p (50) of respiration in 32D cells was determined at 0.05 +/- 0.01 kPa (0.4 mmHg, 0.5 microM, 0.25% air saturation). Close agreement with p (50) of isolated mitochondria indicates that intracellular gradients are small in small cells at routine activity. At intracellular p (O2) respiration is limited by >2% with a p (50) of 0.05 kPa. Over-estimation of p (50) at 0.4 kPa (3 mmHg) would imply significant (>17%) oxygen limitation of respiration under intracellular normoxia. Based on a critical review, we conclude that p (50) ranges from 0.01 to 0.10 kPa in mitochondria and small cells in the absence of inhibitors of cytochrome c oxidase, whereas experimental artefacts explain the controversial >200-fold range of p (50) in the literature on mitochondrial oxygen kinetics.

  14. Supporting BPMN choreography with system integration artefacts for enterprise process collaboration

    Science.gov (United States)

    Nie, Hongchao; Lu, Xudong; Duan, Huilong

    2014-07-01

    Business Process Model and Notation (BPMN) choreography modelling depicts externally visible message exchanges between collaborating processes of enterprise information systems. Implementation of choreography relies on designing system integration solutions to realise message exchanges between independently developed systems. Enterprise integration patterns (EIPs) are widely accepted artefacts to design integration solutions. If the choreography model represents coordination requirements between processes with behaviour mismatches, the integration designer needs to analyse the routing requirements and address these requirements by manually designing EIP message routers. As collaboration scales and complexity increases, manual design becomes inefficient. Thus, the research problem of this paper is to explore a method to automatically identify routing requirements from BPMN choreography model and to accordingly design routing in the integration solution. To achieve this goal, recurring behaviour mismatch scenarios are analysed as patterns, and corresponding solutions are proposed as EIP routers. Using this method, a choreography model can be analysed by computer to identify occurrences of mismatch patterns, leading to corresponding router selection. A case study demonstrates that the proposed method enables computer-assisted integration design to implement choreography. A further experiment reveals that the method is effective to improve the design quality and reduce time cost.

  15. Comparison of Simulated PEC Probe Performance for Detecting Wall Thickness Reduction

    International Nuclear Information System (INIS)

    Shin, Young Kil; Choi, Dong Myung; Jung, Hee Sung

    2009-01-01

    In this paper, four different types of pulsed eddy current(PEC) probe are designed and their performance of detecting wall thickness reduction is compared. By using the backward difference method in time and the finite element method in space, PEC signals from various thickness and materials are numerically calculated and three features of the signal are selected. Since PEC signals and features are obtained by various types and sizes of probe, the comparison is made through the normalized features which reflect the sensitivity of the feature to thickness reduction. The normalized features indicate that the shielded reflection probe provides the best sensitivity to wall thickness reduction for all three signal features. Results show that the best sensitivity to thickness reduction can be achieved by the peak value, but also suggest that the time to peak can be a good candidate because of its linear relationship with the thickness variation.

  16. Spectral artefacts post sputter-etching and how to cope with them - A case study of XPS on nitride-based coatings using monoatomic and cluster ion beams

    Science.gov (United States)

    Lewin, Erik; Counsell, Jonathan; Patscheider, Jörg

    2018-06-01

    The issue of artefacts due to sputter-etching has been investigated for a group of AlN-based thin film materials with varying thermodynamical stability. Stability of the materials was controlled by alloying AlN with the group 14 elements Si, Ge or Sn in two different concentrations. The coatings were sputter-etched with monoatomic Ar+ with energies between 0.2 and 4.0 keV to study the sensitivity of the materials for sputter damage. The use of Arn+ clusters to remove an oxidised surface layer was also evaluated for a selected sample. The spectra were compared to pristine spectra obtained after in-vacuo sample transfer from the synthesis chamber to the analysis instrument. It was found that the all samples were affected by high energy (4 keV) Ar+ ions to varying degrees. The determining factors for the amount of observed damage were found to be the materials' enthalpy of formation, where a threshold value seems to exist at approximately -1.25 eV/atom (∼-120 kJ/mol atoms). For each sample, the observed amount of damage was found to have a linear dependence to the energy deposited by the ion beam per volume removed material. Despite the occurrence of sputter-damage in all samples, etching settings that result in almost artefact-free spectral data were found; using either very low energy (i.e. 200 eV) monoatomic ions, or an appropriate combination of ion cluster size and energy. The present study underlines that analysis post sputter-etching must be carried out with an awareness of possible sputter-induced artefacts.

  17. Optical crosstalk reduction using Amplified Spontaneous Emission (ASE)

    NARCIS (Netherlands)

    Chen, H.; Fontaine, N.K.; Ryf, R.; Alvarado, J.C.; van Weerdenburg, J.A.A.; Amezcua-Correa, R.; Okonkwo, C.; Koonen, A.M.J.

    2018-01-01

    We employ spectrally filtered amplified spontaneous emission as the signal carrier and matched local oscillator to mitigate optical crosstalk. We demonstrate polarization crosstalk reduction in single-mode fiber transmission and modal crosstalk reduction over multimode fiber.

  18. The impact of Digitalization on Business Models: How IT Artefacts, Social Media, and Big Data Force Firms to Innovate Their Business Model

    OpenAIRE

    Bouwman, Harry; de Reuver, Mark; Nikou, Shahrokh

    2017-01-01

    Digital technology has forced entrepreneurs to reconsider their business models (BMs). Although research on entrepreneurial intention and business models is gaining attention, there is still a large knowledge gap on both fields. In this paper, we specifically address the impact of digitalization on business model innovation (BMI). Based on data collected from 338 European small- to medium-sized enterprises (SMEs) actively using IT artefacts, social media, or big data to innovate their busines...

  19. Experimental Comparison of Signal Subspace Based Noise Reduction Methods

    DEFF Research Database (Denmark)

    Hansen, Peter Søren Kirk; Hansen, Per Christian; Hansen, Steffen Duus

    1999-01-01

    The signal subspace approach for non-parametric speech enhancement is considered. Several algorithms have been proposed in the literature but only partly analyzed. Here, the different algorithms are compared, and the emphasis is put onto the limiting factors and practical behavior of the estimators...

  20. Comodulation masking release in bit-rate reduction systems

    DEFF Research Database (Denmark)

    Vestergaard, Martin David; Rasmussen, Karsten Bo; Poulsen, Torben

    1999-01-01

    It has been suggested that the level dependence of the upper masking slope be utilized in perceptual models in bit-rate reduction systems. However, comodulation masking release (CMR) phenomena lead to a reduction of the masking effect when a masker and a probe signal are amplitude modulated...... with the same frequency. In bit-rate reduction systems the masker would be the audio signal and the probe signal would represent the quantization noise. Masking curves have been determined for sinusoids and 1-Bark-wide noise maskers in order to investigate the risk of CMR, when quantizing depths are fixed...... in accordance with psycho-acoustical principles. Masker frequencies of 500 Hz, 1 kHz, and 2 kHz have been investigated, and the masking of pure tone probes has been determined in the first four 1/3 octaves above the masker. Modulation frequencies between 6 and 20 Hz were used with a modulation depth of 0...

  1. Use of neutron diffraction and laser-induced plasma spectroscopy in integrated authentication methodologies of copper alloy artefacts

    International Nuclear Information System (INIS)

    Siano, S.; Bartol, L.; Mencaglia, A.A.; Agresti, J.; Miccio, M.

    2009-01-01

    The present study approaches the general problem of the authentication of copper alloy artefacts of art and historical interest using non-invasive analytical techniques. It aims to demonstrate that a suitable combination of time-of-flight neutron diffraction and laser-induced plasma spectroscopy in integrated multidisciplinary authentication methodologies can provide crucial data for discriminating between genuine archaeological objects and modern counterfeits. After introducing the methodology, which is dedicated in particular to copper alloy figurines of ancient style, two representative authentication case studies are discussed. The results of the work provide evidence that the combination of multiphase analysis using TOF-N D and elemental depth profiles provided by Lips makes it possible to solve most of the present authentication problems.

  2. A cell shrinkage artefact in growth plate chondrocytes with common fixative solutions: importance of fixative osmolarity for maintaining morphology

    Directory of Open Access Journals (Sweden)

    MY Loqman

    2010-05-01

    Full Text Available The remarkable increase in chondrocyte volume is a major determinant in the longitudinal growth of mammalian bones. To permit a detailed morphological study of hypertrophic chondrocytes using standard histological techniques, the preservation of normal chondrocyte morphology is essential. We noticed that during fixation of growth plates with conventional fixative solutions, there was a marked morphological (shrinkage artifact, and we postulated that this arose from the hyper-osmotic nature of these solutions. To test this, we fixed proximal tibia growth plates of 7-day-old rat bones in either (a paraformaldehyde (PFA; 4%, (b glutaraldehyde (GA; 2% with PFA (2% with ruthenium hexamine trichloride (RHT; 0.7%, (c GA (2% with RHT (0.7%, or (d GA (1.3% with RHT (0.5% and osmolarity adjusted to a ‘physiological’ level of ~280mOsm. Using conventional histological methods, confocal microscopy, and image analysis on fluorescently-labelled fixed and living chondrocytes, we then quantified the extent of cell shrinkage and volume change. Our data showed that the high osmolarity of conventional fixatives caused a shrinkage artefact to chondrocytes. This was particularly evident when whole bones were fixed, but could be markedly reduced if bones were sagittally bisected prior to fixation. The shrinkage artefact could be avoided by adjusting the osmolarity of the fixatives to the osmotic pressure of normal extracellular fluids (~280mOsm. These results emphasize the importance of fixative osmolarity, in order to accurately preserve the normal volume/morphology of cells within tissues.

  3. Not all that glitters is gold - Electron microscopy study on uptake of gold nanoparticles in Daphnia magna and related artefacts

    DEFF Research Database (Denmark)

    Jensen, Louise Helene Søgaard; Skjolding, Lars Michael; Thit, Amalie

    2017-01-01

    techniques are used to investigate internalization of 10 nm gold nanoparticles in Daphnia magna gut lumen and gut epithelial cells upon 24h exposure and outline potential artefacts, i.e. high contract precipitates from sample preparation related to these techniques. Light sheet microscopy confirmed...... accumulation of gold nanoparticles in the gut lumen. Scanning transmission electron microscopy and elemental analysis revealed gold nanoparticles attached to the microvilli of gut cells. Interestingly, the peritrophic membrane appeared to act as a semipermeable barrier between the lumen and the gut epithelium...

  4. Regulation of interleukin-4 signaling by extracellular reduction of intramolecular disulfides

    International Nuclear Information System (INIS)

    Curbo, Sophie; Gaudin, Raphael; Carlsten, Mattias; Malmberg, Karl-Johan; Troye-Blomberg, Marita; Ahlborg, Niklas; Karlsson, Anna; Johansson, Magnus; Lundberg, Mathias

    2009-01-01

    Interleukin-4 (IL-4) contains three structurally important intramolecular disulfides that are required for the bioactivity of the cytokine. We show that the cell surface of HeLa cells and endotoxin-activated monocytes can reduce IL-4 intramolecular disulfides in the extracellular space and inhibit binding of IL-4 to the IL-4Rα receptor. IL-4 disulfides were in vitro reduced by thioredoxin 1 (Trx1) and protein disulfide isomerase (PDI). Reduction of IL-4 disulfides by the cell surface of HeLa cells was inhibited by auranofin, an inhibitor of thioredoxin reductase that is an electron donor to both Trx1 and PDI. Both Trx1 and PDI have been shown to be located at the cell surface and our data suggests that these enzymes are involved in catalyzing reduction of IL-4 disulfides. The pro-drug N-acetylcysteine (NAC) that promotes T-helper type 1 responses was also shown to mediate the reduction of IL-4 disulfides. Our data provides evidence for a novel redox dependent pathway for regulation of cytokine activity by extracellular reduction of intramolecular disulfides at the cell surface by members of the thioredoxin enzyme family.

  5. Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique

    Energy Technology Data Exchange (ETDEWEB)

    Katsura, Masaki; Matsuda, Izuru; Akahane, Masaaki; Sato, Jiro; Akai, Hiroyuki; Yasaka, Koichiro; Kunimatsu, Akira; Ohtomo, Kuni [University of Tokyo, Department of Radiology, Graduate School of Medicine, Bunkyo-ku, Tokyo (Japan)

    2012-08-15

    To prospectively evaluate dose reduction and image quality characteristics of chest CT reconstructed with model-based iterative reconstruction (MBIR) compared with adaptive statistical iterative reconstruction (ASIR). One hundred patients underwent reference-dose and low-dose unenhanced chest CT with 64-row multidetector CT. Images were reconstructed with 50 % ASIR-filtered back projection blending (ASIR50) for reference-dose CT, and with ASIR50 and MBIR for low-dose CT. Two radiologists assessed the images in a blinded manner for subjective image noise, artefacts and diagnostic acceptability. Objective image noise was measured in the lung parenchyma. Data were analysed using the sign test and pair-wise Student's t-test. Compared with reference-dose CT, there was a 79.0 % decrease in dose-length product with low-dose CT. Low-dose MBIR images had significantly lower objective image noise (16.93 {+-} 3.00) than low-dose ASIR (49.24 {+-} 9.11, P < 0.01) and reference-dose ASIR images (24.93 {+-} 4.65, P < 0.01). Low-dose MBIR images were all diagnostically acceptable. Unique features of low-dose MBIR images included motion artefacts and pixellated blotchy appearances, which did not adversely affect diagnostic acceptability. Diagnostically acceptable chest CT images acquired with nearly 80 % less radiation can be obtained using MBIR. MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT images without severely compromising image quality. (orig.)

  6. On artefact-free reconstruction of low-energy (30–250 eV) electron holograms

    Energy Technology Data Exchange (ETDEWEB)

    Latychevskaia, Tatiana, E-mail: tatiana@physik.uzh.ch; Longchamp, Jean-Nicolas; Escher, Conrad; Fink, Hans-Werner

    2014-10-15

    Low-energy electrons (30–250 eV) have been successfully employed for imaging individual biomolecules. The most simple and elegant design of a low-energy electron microscope for imaging biomolecules is a lensless setup that operates in the holographic mode. In this work we address the problem associated with the reconstruction from the recorded holograms. We discuss the twin image problem intrinsic to inline holography and the problem of the so-called biprism-like effect specific to low-energy electrons. We demonstrate how the presence of the biprism-like effect can be efficiently identified and circumvented. The presented sideband filtering reconstruction method eliminates the twin image and allows for reconstruction despite the biprism-like effect, which we demonstrate on both, simulated and experimental examples. - Highlights: • Radiation damage-free imaging of individual biomolecules. • Elimination of the twin image in inline holograms. • Circumventing biprism-like effect in low-energy electron holograms. • Artefact-free reconstructions of low-energy electron holograms.

  7. On artefact-free reconstruction of low-energy (30–250 eV) electron holograms

    International Nuclear Information System (INIS)

    Latychevskaia, Tatiana; Longchamp, Jean-Nicolas; Escher, Conrad; Fink, Hans-Werner

    2014-01-01

    Low-energy electrons (30–250 eV) have been successfully employed for imaging individual biomolecules. The most simple and elegant design of a low-energy electron microscope for imaging biomolecules is a lensless setup that operates in the holographic mode. In this work we address the problem associated with the reconstruction from the recorded holograms. We discuss the twin image problem intrinsic to inline holography and the problem of the so-called biprism-like effect specific to low-energy electrons. We demonstrate how the presence of the biprism-like effect can be efficiently identified and circumvented. The presented sideband filtering reconstruction method eliminates the twin image and allows for reconstruction despite the biprism-like effect, which we demonstrate on both, simulated and experimental examples. - Highlights: • Radiation damage-free imaging of individual biomolecules. • Elimination of the twin image in inline holograms. • Circumventing biprism-like effect in low-energy electron holograms. • Artefact-free reconstructions of low-energy electron holograms

  8. Efficacy of 'fine' focal spot imaging in CT abdominal angiography

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Lawrence Chia Wei; Devapalasundaram, Ashwini; Ardley, Nicholas [Monash Health, Department of Diagnostic Imaging, Clayton, Victoria (Australia); Lau, Kenneth K. [Monash Health, Department of Diagnostic Imaging, Clayton, Victoria (Australia); Monash University, Department of Medicine, Faculty of Medicine, Nursing, and Health Sciences, Victoria (Australia); Buchan, Kevin [Phillips Healthcare, Clinical Science, PO Box 312, Mont Albert, Victoria (Australia); Huynh, Minh [RMIT University, School of Mathematical and Geospatial Sciences, Victoria (Australia)

    2014-12-15

    To assess the efficacy of fine focal spot imaging in calcification beam-hardening artefact reduction and vessel clarity on CT abdominal angiography (CTAA). Adult patients of any age and gender who presented for CTAA were included. Thirty-nine patients were examined with a standard focal spot size (SFSS) of 1 x 1 mm in the first 3 months while 31 consecutive patients were examined with a fine focal spot size (FFSS) of 1 x 0.5 mm in the following 3 months. Vessel clarity and calcification beam-hardening artefacts of the abdominal aorta, celiac axis, superior mesenteric artery, inferior mesenteric artery, renal arteries, and iliac arteries were assessed using a 5-point grading scale by two blinded radiologists randomly. Cohen's Kappa test indicated that on average, there was substantial agreement among reviewers for vessel wall clarity and calcification artefact grading. Mann-Whitney test showed that there was a significant difference between the two groups, with FFSS performing significantly better for vessel clarity (U, 6481.50; p < 0.001; r, 0.73) and calcification artefact reduction (U, 1916; p < 0.001; r, 0.77). Fine focus CT angiography produces images with better vessel wall clarity and less vessel calcification beam-hardening artefact. (orig.)

  9. Task-related signal decrease on functional magnetic resonance imaging

    International Nuclear Information System (INIS)

    Hara, Yoshie; Nakamura, Mitsugu; Tamaki, Norihiko; Tamura, Shogo; Kitamura, Junji

    2001-01-01

    An atypical pattern of signal change was identified on functional magnetic resonance (fMR) imaging in pathologic patients. Three normal volunteers and 34 patients with pathologic lesions near the primary motor cortex underwent fMR imaging with echo-planar imaging while performing a hand motor task. Signal intensities were evaluated with the z-score method, and the time course and changes of the signal intensity were calculated. Nine of the 34 patients with pathologic lesions displayed a significant task-related signal reduction in motor-related areas. They also presented a conventional task-related signal increase in other motor-related areas. The time courses of the increase and decrease were the inverse of each other. There was no significant difference between rates of signal increase and decrease. Our findings suggest that this atypical signal decrease is clinically significant, and that impaired vascular reactivity and altered oxygen metabolism could contribute to the task-related signal reduction. Brain areas showing such task-related signal decrease should be preserved at surgery. (author)

  10. Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield.

    Science.gov (United States)

    Price, R; Halson, P; Sampson, M

    1999-05-01

    Shielding the radiosensitive gonads during X-ray exposure has been advocated for plain film radiography for many years. In the UK, gonad shields are not widely employed in routine CT scanning, possibly owing to a perceived difficulty in protecting the gonads from a multidirectional X-ray source. The increasing numbers of CT scanners in the UK, with the large doses they deliver to patients, make potential dose reduction methods an important issue. This study measures the dose reduction achievable by shielding the male gonads with a lead wrap-around protection device. The reductions in dose when shielded both from direct radiation and from indirect radiation scattered from local tissues were studied. The use of the device resulted in a statistically significant reduction in the absorbed testicular dose from both direct and scattered radiation, with no increase in the dose measured in surrounding tissues. In three clinically relevant experimental protocols where the testes were not irradiated directly, the testicular absorbed dose from indirect scatter was reduced by 77-93% of the corresponding non-shielded figure. In these three experiments, image quality was unaltered by the use of the shield. A larger dose reduction was obtained when the shield was used to protect the testes from direct irradiation. However, this was achieved at the expense of considerable image degradation from streak artefact that would effectively prevent the clinical use of the device in this setting.

  11. Noise Reduction of Measurement Data using Linear Digital Filters

    Directory of Open Access Journals (Sweden)

    Hitzmann B.

    2007-12-01

    Full Text Available In this paper Butterworth, Chebyshev (Type I and II and Elliptic digital filters are designed for signal noise reduction. On-line data measurements of substrate concentration from E. coli fed-batch cultivation process are used. Application of the designed filters leads to a successful noise reduction of on-line glucose measurements. The digital filters presented here are simple, easy to implement and effective - the used filters allow for a smart compromise between signal information and noise corruption.

  12. Calcium signalling silencing in atrial fibrillation.

    Science.gov (United States)

    Greiser, Maura

    2017-06-15

    Subcellular calcium signalling silencing is a novel and distinct cellular and molecular adaptive response to rapid cardiac activation. Calcium signalling silencing develops during short-term sustained rapid atrial activation as seen clinically during paroxysmal atrial fibrillation (AF). It is the first 'anti-arrhythmic' adaptive response in the setting of AF and appears to counteract the maladaptive changes that lead to intracellular Ca 2+ signalling instability and Ca 2+ -based arrhythmogenicity. Calcium signalling silencing results in a failed propagation of the [Ca 2+ ] i signal to the myocyte centre both in patients with AF and in a rabbit model. This adaptive mechanism leads to a substantial reduction in the expression levels of calcium release channels (ryanodine receptors, RyR2) in the sarcoplasmic reticulum, and the frequency of Ca 2+ sparks and arrhythmogenic Ca 2+ waves remains low. Less Ca 2+ release per [Ca 2+ ] i transient, increased fast Ca 2+ buffering strength, shortened action potentials and reduced L-type Ca 2+ current contribute to a substantial reduction of intracellular [Na + ]. These features of Ca 2+ signalling silencing are distinct and in contrast to the changes attributed to Ca 2+ -based arrhythmogenicity. Some features of Ca 2+ signalling silencing prevail in human AF suggesting that the Ca 2+ signalling 'phenotype' in AF is a sum of Ca 2+ stabilizing (Ca 2+ signalling silencing) and Ca 2+ destabilizing (arrhythmogenic unstable Ca 2+ signalling) factors. Calcium signalling silencing is a part of the mechanisms that contribute to the natural progression of AF and may limit the role of Ca 2+ -based arrhythmogenicity after the onset of AF. © 2017 The Authors. The Journal of Physiology © 2017 The Physiological Society.

  13. Provenance analysis of Roman stone artefacts from sedimentary rocks from the archaeological site near Mošnje, NW Slovenia

    Directory of Open Access Journals (Sweden)

    Snježana Miletić

    2016-08-01

    Full Text Available This study deals with the macroscopic and microfacies characterisation of Roman stone artefacts excavated in 2006 from a Roman villa rustica near Mošnje (NW Slovenia with the aim of defiing their provenance. A total of 28 representative fids (querns, mortars, whetstones, tooled and rounded stones, a fragment of stone slab, mosaic tesserae and two architectural elements - one with a relief made of clastic and carbonate sedimentary rocks were examined. Comparison was made with rock samples taken from quarries and gravel bars close to the archaeological site, as well as from larger distance to the site. The majority of artefact sampled is composed of Upper Palaeozoic quartz sandstones, which are found as pebbles in gravel bars close to the archaeological site; while 2 samples were from Quaternary coarse grained clastic rocks which can be found in local glacio-flvial sediments. Other fids were made of four different Mesozoic shallow-water limestones which outcrop in different areas of Central and SW Slovenia. The nearest Lower Jurassic biopelmicritic limestones are found at the western periphery of Ljubljana in Podutik. Cretaceous miliolid limestones and biocalcarenitic limestones with rudists are common in the successions of the Dinaric Carbonate Platform in SW Slovenia (for example, on the Trieste-Komen Plateau, NE Italy and SW Croatia. This indicates that the limestones for architectural elements, stone mortars and tesserae were brought to Mošnje from distant locations. Smaller stone tools are likely to have been made at the location of the archaeological site from material gathered locally, mostly pebbles from clastic rocks, which were accessible and suitable for tooling.

  14. Re-Appraisal of Estrogen Receptor Negative/Progesterone Receptor Positive (ER-/PR+) Breast Cancer Phenotype: True Subtype or Technical Artefact?

    Science.gov (United States)

    Foley, Niamh M; Coll, J M; Lowery, A J; Hynes, S O; Kerin, M J; Sheehan, M; Brodie, C; Sweeney, K J

    2017-09-11

    Expression of the ER and PR receptors is routinely quantified in breast cancer as a predictive marker of response to hormonal therapy. Accurate determination of ER and PR status is critical to the optimal selection of patients for targeted therapy. The existence of an ER-/PR+ subtype is controversial, with debate centred on whether this represents a true phenotype or a technical artefact on immunohistochemistry (IHC). The aim of this study was to investigate the true incidence and clinico-pathological features of ER-/PR+ breast cancers in a tertiary referral symptomatic breast unit. Clinico-pathological data were collected on invasive breast cancers diagnosed between 1995 and 2005. IHC for ER and PR receptors was repeated on all cases which were ER-/PR+, with the same paraffin block used for the initial diagnostic testing. Concordance between the diagnostic and repeat IHC was determined using validated testing. Complete data, including ER and PR status were available for 697 patients diagnosed during the study period. On diagnostic IHC, the immunophenotype of the breast tumours was: ER+/PR+ in 396 (57%), ER-/PR- in 157 (23%), ER+/PR- in 88 (12%) and ER-/PR+ in 56 (8.6%) patients. On repeat IHC of 48/56 ER-/PR+ tumours 45.8% were ER+/PR+, 6% were ER+/PR- and 43.7% were ER-/PR- None of the cases were confirmed to be ER-/PR+. The ER-/PR+ phenotypic breast cancer is likely to be the result of technical artefact. Prompt reassessment of patients originally assigned to this subtype who re-present with symptoms should be considered to ensure appropriate clinical management.

  15. Image quality of iterative reconstruction in cranial CT imaging: comparison of model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASiR).

    Science.gov (United States)

    Notohamiprodjo, S; Deak, Z; Meurer, F; Maertz, F; Mueck, F G; Geyer, L L; Wirth, S

    2015-01-01

    The purpose of this study was to compare cranial CT (CCT) image quality (IQ) of the MBIR algorithm with standard iterative reconstruction (ASiR). In this institutional review board (IRB)-approved study, raw data sets of 100 unenhanced CCT examinations (120 kV, 50-260 mAs, 20 mm collimation, 0.984 pitch) were reconstructed with both ASiR and MBIR. Signal-to-noise (SNR) and contrast-to-noise (CNR) were calculated from attenuation values measured in caudate nucleus, frontal white matter, anterior ventricle horn, fourth ventricle, and pons. Two radiologists, who were blinded to the reconstruction algorithms, evaluated anonymized multiplanar reformations of 2.5 mm with respect to depiction of different parenchymal structures and impact of artefacts on IQ with a five-point scale (0: unacceptable, 1: less than average, 2: average, 3: above average, 4: excellent). MBIR decreased artefacts more effectively than ASiR (p ASiR was 2 (p ASiR (p ASiR. As CCT is an examination that is frequently required, the use of MBIR may allow for substantial reduction of radiation exposure caused by medical diagnostics. • Model-Based iterative reconstruction (MBIR) effectively decreased artefacts in cranial CT. • MBIR reconstructed images were rated with significantly higher scores for image quality. • Model-Based iterative reconstruction may allow reduced-dose diagnostic examination protocols.

  16. Reduction of heart sound interference from lung sound signals using empirical mode decomposition technique.

    Science.gov (United States)

    Mondal, Ashok; Bhattacharya, P S; Saha, Goutam

    2011-01-01

    During the recording time of lung sound (LS) signals from the chest wall of a subject, there is always heart sound (HS) signal interfering with it. This obscures the features of lung sound signals and creates confusion on pathological states, if any, of the lungs. A novel method based on empirical mode decomposition (EMD) technique is proposed in this paper for reducing the undesired heart sound interference from the desired lung sound signals. In this, the mixed signal is split into several components. Some of these components contain larger proportions of interfering signals like heart sound, environmental noise etc. and are filtered out. Experiments have been conducted on simulated and real-time recorded mixed signals of heart sound and lung sound. The proposed method is found to be superior in terms of time domain, frequency domain, and time-frequency domain representations and also in listening test performed by pulmonologist.

  17. Microcontroller - Based System for Electrogastrography Monitoring Through Wireless Transmission

    Science.gov (United States)

    Haddab, S.; Laghrouche, M.

    2009-01-01

    Electrogastrography (EGG) is a non-invasive method for recording the electrical activity of the stomach. This paper presents a system designed for monitoring the EGG physiological variables of a patient outside the hospital environment. The signal acquisition is achieved by means of an ambulatory system carried by the patient and connected to him through skin electrodes. The acquired signal is transmitted via the Bluetooth to a mobile phone where the data are stored into the memory and then transferred via the GSM network to the processing and diagnostic unit in the hospital. EGG is usually contaminated by artefacts and other signals, which are sometimes difficult to remove. We have used a neural network method for motion artefacts removal and biological signal separation.

  18. Evaluation of Clipping Based Iterative PAPR Reduction Techniques for FBMC Systems

    Directory of Open Access Journals (Sweden)

    Zsolt Kollár

    2014-01-01

    to conventional orthogonal frequency division multiplexing (OFDM technique. The low ACLR of the transmitted FBMC signal makes it especially favorable in cognitive radio applications, where strict requirements are posed on out-of-band radiation. Large dynamic range resulting in high peak-to-average power ratio (PAPR is characteristic of all sorts of multicarrier signals. The advantageous spectral properties of the high-PAPR FBMC signal are significantly degraded if nonlinearities are present in the transceiver chain. Spectral regrowth may appear, causing harmful interference in the neighboring frequency bands. This paper presents novel clipping based PAPR reduction techniques, evaluated and compared by simulations and measurements, with an emphasis on spectral aspects. The paper gives an overall comparison of PAPR reduction techniques, focusing on the reduction of the dynamic range of FBMC signals without increasing out-of-band radiation. An overview is presented on transmitter oriented techniques employing baseband clipping, which can maintain the system performance with a desired bit error rate (BER.

  19. Noise reduction methods for nucleic acid and macromolecule sequencing

    Science.gov (United States)

    Schuller, Ivan K.; Di Ventra, Massimiliano; Balatsky, Alexander

    2018-05-08

    Methods, systems, and devices are disclosed for processing macromolecule sequencing data with substantial noise reduction. In one aspect, a method for reducing noise in a sequential measurement of a macromolecule comprising serial subunits includes cross-correlating multiple measured signals of a physical property of subunits of interest of the macromolecule, the multiple measured signals including the time data associated with the measurement of the signal, to remove or at least reduce signal noise that is not in the same frequency and in phase with the systematic signal contribution of the measured signals.

  20. Interaction of pulse laser radiation of 532 nm with model coloration layers for medieval stone artefacts

    Energy Technology Data Exchange (ETDEWEB)

    Colson, J. [University of Vienna, Department of Physical Chemistry, A-1090 Vienna (Austria); Nimmrichter, J. [Austrian Federal Office for the Care of Monuments, Department for Conservation and Restoration, Arsenal, Objekt 15, Tor 4, A-1030 Vienna (Austria); Kautek, W., E-mail: wolfgang.kautek@univie.ac.at [University of Vienna, Department of Physical Chemistry, A-1090 Vienna (Austria)

    2014-05-01

    Multilayer polychrome coatings on medieval and Renaissance stone artefacts represent substantial challenges in laser cleaning. Therefore, polychromic models with classical pigments, minium (Pb{sub 2}{sup 2+}Pb{sup 4+}O{sub 4}), zinc white (ZnO), and lead white ((PbCO{sub 3}){sub 2}·Pb(OH){sub 2}) in an acrylic binder, were irradiated with a Q-switched Nd:YAG laser emitting at 532 nm. The studied medieval pigments exhibit strongly varying incubation behaviours directly correlated to their band gap energies. Higher band gaps beyond the laser photon energy of 2.3 eV require more incubative generation of defects for resonant transitions. A matching of the modification thresholds after more than four laser pulses was observed. Laser cleaning with multiple pulsing should not exceed ca. 0.05 J/cm{sup 2} when these pigments coexist in close spatial proximity.

  1. Multichannel Signal Enhancement using Non-Causal, Time-Domain Filters

    DEFF Research Database (Denmark)

    Jensen, Jesper Rindom; Christensen, Mads Græsbøll; Benesty, Jacob

    2013-01-01

    In the vast amount of time-domain filtering methods for speech enhancement, the filters are designed to be causal. Recently, however, it was shown that the noise reduction and signal distortion capabilities of such single-channel filters can be improved by allowing the filters to be non-causal. W......In the vast amount of time-domain filtering methods for speech enhancement, the filters are designed to be causal. Recently, however, it was shown that the noise reduction and signal distortion capabilities of such single-channel filters can be improved by allowing the filters to be non......-causal, multichannel filters for enhancement based on an orthogonal decomposition is proposed. The evaluation shows that there is a potential gain in noise reduction and signal distortion by introducing non-causality. Moreover, experiments on real-life speech show that we can improve the perceptual quality....

  2. Effect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI

    Directory of Open Access Journals (Sweden)

    Golestan karami

    2013-03-01

    Full Text Available Introduction Echo-planar imaging (EPI is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that causes more geometric distortion in phase encoding direction. This inhomogeneity is induced mainly by the magnetic susceptibility differences between various structures within the object placed inside the scanner, often at air-tissue or bone-tissue interfaces. Methods of reducing EPI distortion are mainly based on decreasing steps of the phase encoding. Reducing steps of phase encoding can be applied by reducing field of view, slice thickness, and/or the use of parallel acquisition technique. Materials and Methods We obtained three data acquisitions with different FOVs including: conventional low resolution, conventional high resolution, and zoomed high resolution EPIs. Moreover we used SENSE technique for phase encoding reduction. All experiments were carried out on three Tesla scanners (Siemens, TIM, and Germany equipped with 12 channel head coil. Ten subjects participated in the experiments. Results The data were processed by FSL software and were evaluated by ANOVA. Distortion was assessed by obtaining low displacement voxels map, and calculated from a field map image. Conclusion We showed that image distortion can be reduced by decreasing slice thickness and phase encoding steps. Distortion reduction in zoomed technique resulted the lowest level, but at the cost of signal-to-noise loss. Moreover, the SENSE technique was shown to decrease the amount of image distortion, efficiently.

  3. Adaptive noise reduction circuit for a sound reproduction system

    Science.gov (United States)

    Engebretson, A. Maynard (Inventor); O'Connell, Michael P. (Inventor)

    1995-01-01

    A noise reduction circuit for a hearing aid having an adaptive filter for producing a signal which estimates the noise components present in an input signal. The circuit includes a second filter for receiving the noise-estimating signal and modifying it as a function of a user's preference or as a function of an expected noise environment. The circuit also includes a gain control for adjusting the magnitude of the modified noise-estimating signal, thereby allowing for the adjustment of the magnitude of the circuit response. The circuit also includes a signal combiner for combining the input signal with the adjusted noise-estimating signal to produce a noise reduced output signal.

  4. Noise Reduction in the Time Domain using Joint Diagonalization

    DEFF Research Database (Denmark)

    Nørholm, Sidsel Marie; Benesty, Jacob; Jensen, Jesper Rindom

    2014-01-01

    , an estimate of the desired signal is found by subtraction of the noise estimate from the observed signal. The filter can be designed to obtain a desired trade-off between noise reduction and signal distortion, depending on the number of eigenvectors included in the filter design. This is explored through...... simulations using a speech signal corrupted by car noise, and the results confirm that the output signal-to-noise ratio and speech distortion index both increase when more eigenvectors are included in the filter design....

  5. Noise Reduction with Microphone Arrays for Speaker Identification

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, Z

    2011-12-22

    Reducing acoustic noise in audio recordings is an ongoing problem that plagues many applications. This noise is hard to reduce because of interfering sources and non-stationary behavior of the overall background noise. Many single channel noise reduction algorithms exist but are limited in that the more the noise is reduced; the more the signal of interest is distorted due to the fact that the signal and noise overlap in frequency. Specifically acoustic background noise causes problems in the area of speaker identification. Recording a speaker in the presence of acoustic noise ultimately limits the performance and confidence of speaker identification algorithms. In situations where it is impossible to control the environment where the speech sample is taken, noise reduction filtering algorithms need to be developed to clean the recorded speech of background noise. Because single channel noise reduction algorithms would distort the speech signal, the overall challenge of this project was to see if spatial information provided by microphone arrays could be exploited to aid in speaker identification. The goals are: (1) Test the feasibility of using microphone arrays to reduce background noise in speech recordings; (2) Characterize and compare different multichannel noise reduction algorithms; (3) Provide recommendations for using these multichannel algorithms; and (4) Ultimately answer the question - Can the use of microphone arrays aid in speaker identification?

  6. Exploring young children’s artefact engagements as premises for creating purposeful intergenerational knowledge of digitalized everyday life

    DEFF Research Database (Denmark)

    Chimirri, Niklas Alexander

    The presentation takes its point of departure in a major current expression of the top-down steering rationale in Danish Early Childhood Education and Care, namely the process of digitalization of childcare institutions. While the promotion of using digital artefacts in childcare can be seen...... as reflecting actual and seemingly unavoidable current transformations of the everyday life of adults and children across all societal practices, rendering the political wish to strengthening the digital media literacy of its ‘future citizens’ comprehensible, the ways in which digitalization is promoted...... by state policies accounts little for the ambivalences of digitalized everyday life at home and other relevant contexts. Instead of taking adults’ and children’s digital being seriously and granting opportunities to jointly explore digital artefacts’ possibilities and limitations, hence, childcare...

  7. From artefacts to atoms - A new SI for 2018 to be based on fundamental constants.

    Science.gov (United States)

    Quinn, Terry

    At the 26th General Conference on Weights and Measures (CGPM) in November 2018, it is planned to adopt a new definition of the International System of Units, SI, based on the fixed numerical values of seven defining constants, broadly the fundamental constants of physics. This will be the culmination of more than two hundred years of metrology, instantiating for the first time the original ideas of the creators of the metric system. The key is the replacement of the present definition of the unit of mass, the kilogram artefact of platinum-iridium, by one based on a fixed numerical value of the Planck constant. This article outlines how this has come about, how it will work, why we need a system of measurement that is uniform, accessible world-wide and stable in the long term, and the international structures that now exist to achieve it. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Improvement of electrocardiogram by empirical wavelet transform

    Science.gov (United States)

    Chanchang, Vikanda; Kumchaiseemak, Nakorn; Sutthiopad, Malee; Luengviriya, Chaiya

    2017-09-01

    Electrocardiogram (ECG) is a crucial tool in the detection of cardiac arrhythmia. It is also often used in a routine physical exam, especially, for elderly people. This graphical representation of electrical activity of heart is obtained by a measurement of voltage at the skin; therefore, the signal is always contaminated by noise from various sources. For a proper interpretation, the quality of the ECG should be improved by a noise reduction. In this article, we present a study of a noise filtration in the ECG by using an empirical wavelet transform (EWT). Unlike the traditional wavelet method, EWT is adaptive since the frequency spectrum of the ECG is taken into account in the construction of the wavelet basis. We show that the signal-to-noise ratio increases after the noise filtration for different noise artefacts.

  9. The artefacts of radiochromic film dosimetry with flatbed scanners and their causation by light scattering from radiation-induced polymers.

    Science.gov (United States)

    Schoenfeld, Andreas A; Poppinga, Daniela; Harder, Dietrich; Doerner, Karl-Joachim; Poppe, Bjoern

    2014-07-07

    Optical experiments and theoretical considerations have been undertaken in order to understand the causes of the 'orientation effect' and the 'parabola effect', the artefacts impairing the desired light absorption measurement on radiochromic EBT3 films with flatbed scanners. EBT3 films exposed to doses up to 20.9 Gy were scanned with an Epson Expression 10000XL flatbed scanner in landscape and portrait orientation. The horizontally and vertically polarized light components of the scanner were determined, and another Epson Expression 10000XL flatbed scanner was disassembled to examine its optical components. The optical properties of exposed and unexposed EBT3 films were studied with incident polarized and unpolarized white light, and the transmitted red light was investigated for its polarization and scattering properties including the distribution of the scattering angles. Neutral density filters were studied for comparison. Guidance was sought from the theory of light scattering from rod-like macromolecular structures. The drastic dose-dependent variation of the transmitted total light current as function of the orientation of front and rear polarizers, interpreted by light scattering theory, shows that the radiation-induced polymerization of the monomers of EBT3 films produces light scattering oscillators preferably polarized at right angles with the coating direction of the film. The directional distribution of the scattered light is partly anisotropic, with a preferred scattering plane at right angles with the coating direction, indicating light scattering from stacks of coherently vibrating oscillators piled up along the monomer crystals. The polyester carrier film also participates in these effects. The 'orientation' and 'parabola' artefacts due to flatbed scanning of radiochromic films can be explained by the interaction of the polarization-dependent and anisotropic light scattering from exposed and unexposed EBT3 films with the quantitative difference

  10. Model-based iterative reconstruction technique for radiation dose reduction in chest CT: comparison with the adaptive statistical iterative reconstruction technique

    International Nuclear Information System (INIS)

    Katsura, Masaki; Matsuda, Izuru; Akahane, Masaaki; Sato, Jiro; Akai, Hiroyuki; Yasaka, Koichiro; Kunimatsu, Akira; Ohtomo, Kuni

    2012-01-01

    To prospectively evaluate dose reduction and image quality characteristics of chest CT reconstructed with model-based iterative reconstruction (MBIR) compared with adaptive statistical iterative reconstruction (ASIR). One hundred patients underwent reference-dose and low-dose unenhanced chest CT with 64-row multidetector CT. Images were reconstructed with 50 % ASIR-filtered back projection blending (ASIR50) for reference-dose CT, and with ASIR50 and MBIR for low-dose CT. Two radiologists assessed the images in a blinded manner for subjective image noise, artefacts and diagnostic acceptability. Objective image noise was measured in the lung parenchyma. Data were analysed using the sign test and pair-wise Student's t-test. Compared with reference-dose CT, there was a 79.0 % decrease in dose-length product with low-dose CT. Low-dose MBIR images had significantly lower objective image noise (16.93 ± 3.00) than low-dose ASIR (49.24 ± 9.11, P < 0.01) and reference-dose ASIR images (24.93 ± 4.65, P < 0.01). Low-dose MBIR images were all diagnostically acceptable. Unique features of low-dose MBIR images included motion artefacts and pixellated blotchy appearances, which did not adversely affect diagnostic acceptability. Diagnostically acceptable chest CT images acquired with nearly 80 % less radiation can be obtained using MBIR. MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT images without severely compromising image quality. (orig.)

  11. Thylakoid redox signals are integrated into organellar-gene-expression-dependent retrograde signalling in the prors1-1 mutant

    Directory of Open Access Journals (Sweden)

    Luca eTadini

    2012-12-01

    Full Text Available Perturbations in organellar gene expression (OGE and the thylakoid redox state (TRS activate retrograde signalling pathways that adaptively modify nuclear gene expression (NGE, according to developmental and metabolic needs. The prors1-1 mutation in Arabidopsis down-regulates the expression of the nuclear gene Prolyl-tRNA Synthetase1 (PRORS1 which acts in both plastids and mitochondria, thereby impairing protein synthesis in both organelles and triggering OGE-dependent retrograde signalling. Because the mutation also affects thylakoid electron transport, TRS-dependent signals may likewise have an impact on the changes in NGE observed in this genotype. In this study, we have investigated whether signals related to TRS are actually integrated into the OGE-dependent retrograde signalling pathway. To this end, the chaos mutation (for chlorophyll a/b binding protein harvesting-organelle specific, which shows a partial loss of PSII antennae proteins and thus a reduction in PSII light absorption capability, was introduced into the prors1-1 mutant background. The resulting double mutant displayed a prors1-1-like reduction in plastid translation rate and a chaos-like decrease in PSII antenna size, whereas the hyper-reduction of the thylakoid electron transport chain, caused by the prors1-1 mutation, was alleviated, as determined by monitoring chlorophyll (Chl fluorescence and thylakoid phosphorylation. Interestingly, a substantial fraction of the nucleus-encoded photosynthesis genes down-regulated in the prors1-1 mutant are expressed at nearly wild-type rates in prors1-1 chaos leaves, and this recovery is reflected in the steady-state levels of their protein products in the chloroplast. We therefore conclude that signals related to photosynthetic electron transport and TRS, and indirectly to carbohydrate metabolism and energy balance, are indeed fed into the OGE-dependent retrograde pathway to modulate NGE and adjust the abundance of chloroplast proteins.

  12. A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures

    International Nuclear Information System (INIS)

    Lang, H.; Neubauer, J.; Fritz, B.; Spira, E.M.; Strube, J.; Langer, M.; Kotter, E.

    2016-01-01

    To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall's coefficient of concordance. CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. (orig.)

  13. Non-Cartesian MRI scan time reduction through sparse sampling

    NARCIS (Netherlands)

    Wajer, F.T.A.W.

    2001-01-01

    Non-Cartesian MRI Scan-Time Reduction through Sparse Sampling Magnetic resonance imaging (MRI) signals are measured in the Fourier domain, also called k-space. Samples of the MRI signal can not be taken at will, but lie along k-space trajectories determined by the magnetic field gradients. MRI

  14. Signalling in international environmental agreements. Using pre-agreement emission level as a signalling device

    Energy Technology Data Exchange (ETDEWEB)

    Steiner, U.

    1997-12-31

    This paper addresses the question about strategic incentives in international environmental agreements and tries to give a positive description of how the design of the agreement influences the strategic behaviour of potential participants before they enter the treaty. A common feature of the design of agreements is that the reduction obligations (RO) are made contingent on a pre-agreement or baseline emission. As it is assumed that countries posses better information about their reduction costs than does the international body in charge of deciding the RO, countries might have incentives to signal higher costs by increasing their baseline emission, and thereby reducing the costs of entering the agreement. The appropriate analytical framework is to use a signalling game approach, where the pre-agreement emission level conveys information about the privately informed country`s reduction cost. In this paper two types of agreement design are considered, one with uniform obligations, and one with differentiated obligations. This enables us to make a comparison between two different reduction regimes. The result is that the predicted outcomes vary with regard to both the environmental effectiveness and the associated expected costs for the participating countries. This means that when private information is considered, the anticipation of a given institutional framework has significant impact on the resulting distortion of the total emission level, highlighting the necessity of taking this into consideration when future designs are proposed. (au)

  15. Signalling in international environmental agreements: Using pre-agreement emission level as a signalling device

    International Nuclear Information System (INIS)

    Steiner, U.

    1997-01-01

    This paper addresses the question about strategic incentives in international environmental agreements and tries to give a positive description of how the design of the agreement influences the strategic behaviour of potential participants before they enter the treaty. A common feature of the design of agreements is that the reduction obligations (RO) are made contingent on a pre-agreement or baseline emission. As it is assumed that countries posses better information about their reduction costs than does the international body in charge of deciding the RO, countries might have incentives to signal higher costs by increasing their baseline emission, and thereby reducing the costs of entering the agreement. The appropriate analytical framework is to use a signalling game approach, where the pre-agreement emission level conveys information about the privately informed country's reduction cost. In this paper two types of agreement design are considered, one with uniform obligations, and one with differentiated obligations. This enables us to make a comparison between two different reduction regimes. The result is that the predicted outcomes vary with regard to both the environmental effectiveness and the associated expected costs for the participating countries. This means that when private information is considered, the anticipation of a given institutional framework has significant impact on the resulting distortion of the total emission level, highlighting the necessity of taking this into consideration when future designs are proposed. (au)

  16. Interferometric crosstalk reduction by phase scrambling

    NARCIS (Netherlands)

    Tafur Monroy, I.; Tangdiongga, E.; Jonker, R.J.W.; Waardt, de H.

    2000-01-01

    Interferometric crosstalk, arising from the detection of undesired signals at the same nominal wavelength, may introduce large power penalties and bit-error rate (BER) floor significantly restricting the scalability of optical networks. In this paper, interferometric crosstalk reduction in optical

  17. Portable XRF on Prehistoric Bronze Artefacts: Limitations and Use for the Detection of Bronze Age Metal Workshops

    DEFF Research Database (Denmark)

    Nørgaard, Heide Wrobel

    2017-01-01

    sections were analysed using a scanning electron microscope (SEM). Results from the corrosion crust of copper-tin alloys, and the change measured within the elemental composition from the bulk metal to the surface, greatly influenced the interpretation of the second data set, which was measured using......Two different scientific analyses—one destructive and one non destructive—were conducted on two separate groups of bronze ornaments dating from 1500–1100 BC to investigate, amongst other traits, the metal composition of their copper-tin alloys. One group of artefacts was sampled, and polished thin...... a handheld X-ray fluorescence (XRF) device. The surface of corroded bronze ornaments consists mostly of copper carbonates, oxides, and chlorides. Chemical processes, such as decuprification, change the element composition in such a manner that the original alloy cannot be traced with a non-destructive method...

  18. Dynamics of BMP signaling in limb bud mesenchyme and polydactyly.

    Science.gov (United States)

    Norrie, Jacqueline L; Lewandowski, Jordan P; Bouldin, Cortney M; Amarnath, Smita; Li, Qiang; Vokes, Martha S; Ehrlich, Lauren I R; Harfe, Brian D; Vokes, Steven A

    2014-09-15

    Mutations in the Bone Morphogenetic Protein (BMP) pathway are associated with a range of defects in skeletal formation. Genetic analysis of BMP signaling requirements is complicated by the presence of three partially redundant BMPs that are required for multiple stages of limb development. We generated an inducible allele of a BMP inhibitor, Gremlin, which reduces BMP signaling. We show that BMPs act in a dose and time dependent manner in which early reduction of BMPs result in digit loss, while inhibiting overall BMP signaling between E10.5 and E11.5 allows polydactylous digit formation. During this period, inhibiting BMPs extends the duration of FGF signaling. Sox9 is initially expressed in normal digit ray domains but at reduced levels that correlate with the reduction in BMP signaling. The persistence of elevated FGF signaling likely promotes cell proliferation and survival, inhibiting the activation of Sox9 and secondarily, inhibiting the differentiation of Sox9-expressing chondrocytes. Our results provide new insights into the timing and clarify the mechanisms underlying BMP signaling during digit morphogenesis. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Comparative Laser Spectroscopy Diagnostics for Ancient Metallic Artefacts Exposed to Environmental Pollution

    Directory of Open Access Journals (Sweden)

    Łukasz Ciupiński

    2010-05-01

    Full Text Available Metal artworks are subjected to corrosion and oxidation processes due to reactive agents present in the air, water and in the ground that these objects have been in contact with for hundreds of years. This is the case for archaeological metals that are recovered from excavation sites, as well as artefacts exposed to polluted air. Stabilization of the conservation state of these objects needs precise diagnostics of the accrued surface layers and identification of original, historical materials before further protective treatments, including safe laser cleaning of unwanted layers. This paper presents analyses of the chemical composition and stratigraphy of corrosion products with the use of laser induced breakdown spectroscopy (LIBS and Raman spectroscopy. The discussion of the results is supported by material studies (SEM-EDS, XRF, ion-analyses. The tests were performed on several samples taken from original objects, including copper roofing from Wilanów Palace in Warsaw and Karol Poznański Palace in Łódź, bronze decorative figures from the Wilanów Palace gardens, and four archaeological examples of old jewellery (different copper alloys. Work has been performed as a part of the MATLAS project in the frames of EEA and Norway Grants (www.matlas.eu and the results enable the comparison of the methodology and to elaborate the joint diagnostic procedures of the three project partner independent laboratories.

  20. Comparative Laser Spectroscopy Diagnostics for Ancient Metallic Artefacts Exposed to Environmental Pollution

    Science.gov (United States)

    Ciupiński, Łukasz; Fortuna-Zaleśna, Elżbieta; Garbacz, Halina; Koss, Andrzej; Kurzydłowski, Krzysztof J.; Marczak, Jan; Mróz, Janusz; Onyszczuk, Tomasz; Rycyk, Antoni; Sarzyński, Antoni; Skrzeczanowski, Wojciech; Strzelec, Marek; Zatorska, Anna; Żukowska, Grażyna Z.

    2010-01-01

    Metal artworks are subjected to corrosion and oxidation processes due to reactive agents present in the air, water and in the ground that these objects have been in contact with for hundreds of years. This is the case for archaeological metals that are recovered from excavation sites, as well as artefacts exposed to polluted air. Stabilization of the conservation state of these objects needs precise diagnostics of the accrued surface layers and identification of original, historical materials before further protective treatments, including safe laser cleaning of unwanted layers. This paper presents analyses of the chemical composition and stratigraphy of corrosion products with the use of laser induced breakdown spectroscopy (LIBS) and Raman spectroscopy. The discussion of the results is supported by material studies (SEM-EDS, XRF, ion-analyses). The tests were performed on several samples taken from original objects, including copper roofing from Wilanów Palace in Warsaw and Karol Poznański Palace in ŁódŸ, bronze decorative figures from the Wilanów Palace gardens, and four archaeological examples of old jewellery (different copper alloys). Work has been performed as a part of the MATLAS project in the frames of EEA and Norway Grants (www.matlas.eu) and the results enable the comparison of the methodology and to elaborate the joint diagnostic procedures of the three project partner independent laboratories. PMID:22399915

  1. Phase noise mitigation of QPSK signal utilizing phase-locked multiplexing of signal harmonics and amplitude saturation.

    Science.gov (United States)

    Mohajerin-Ariaei, Amirhossein; Ziyadi, Morteza; Chitgarha, Mohammad Reza; Almaiman, Ahmed; Cao, Yinwen; Shamee, Bishara; Yang, Jeng-Yuan; Akasaka, Youichi; Sekiya, Motoyoshi; Takasaka, Shigehiro; Sugizaki, Ryuichi; Touch, Joseph D; Tur, Moshe; Langrock, Carsten; Fejer, Martin M; Willner, Alan E

    2015-07-15

    We demonstrate an all-optical phase noise mitigation scheme based on the generation, delay, and coherent summation of higher order signal harmonics. The signal, its third-order harmonic, and their corresponding delayed variant conjugates create a staircase phase-transfer function that quantizes the phase of quadrature-phase-shift-keying (QPSK) signal to mitigate phase noise. The signal and the harmonics are automatically phase-locked multiplexed, avoiding the need for phase-based feedback loop and injection locking to maintain coherency. The residual phase noise converts to amplitude noise in the quantizer stage, which is suppressed by parametric amplification in the saturation regime. Phase noise reduction of ∼40% and OSNR-gain of ∼3  dB at BER 10(-3) are experimentally demonstrated for 20- and 30-Gbaud QPSK input signals.

  2. A comparison of prone SPET and left lateral (decubitus) planar imaging for inferior wall attenuation artefact in 201Tl myocardial imaging

    International Nuclear Information System (INIS)

    O'Donnell, M.; Jenkin, B.; Van Every, B.; Kelly, M.J.; Kalff, V.

    1999-01-01

    Full text: Inferior wall attenuation artefacts are a major problem in supine SPET (S-S) myocardial perfusion imaging. SPET imaging with the patient lying in the prone position (P-S) and left lateral planar imaging with the patient lying in the right lateral decubitus position (LL) ameliorate this artefact. This study attempts to define the clinical role of P-S and LL imaging in characterizing S-S inferior wall defects. 21 patients with an inferior wall defect on S-S then had LL and rapid P-S imaging. All images were performed with a GE Optima NX gamma camera using GENIE acquisition and processing. All SPETs used 16 stops (32 frames) through 90 deg, with 40 s per stop for SS and 14 s per stop for P-S. LL images were acquired for 150 s. All images were assessed for adequacy and inferior wall scored for 0 = no, 1 mild, 2 moderate and 3 = severe defects. Statistical analysis was performed using the Wilcoxon rank sum test for matched pairs. All images were adequate for analysis. Significantly fewer defects were seen in P-S vs S-S, LL vs S-S (P 0.88); however; there was a difference (P < 0.05) in the subgroup (n = 7) with moderate defects on S-S imaging but no LL defect. In conclusion, most inferior wall defects seen on S-S imaging can be attributed to either attenuation or true perfusion defects with the use of LL imaging. Prone imaging may only be helpful where the inferior defect is of moderate severity but no LL defect is seen

  3. Radiation dose reduction in paediatric coronary computed tomography: assessment of effective dose and image quality

    International Nuclear Information System (INIS)

    Habib Geryes, Bouchra; Calmon, Raphael; Boddaert, Nathalie; Khraiche, Diala; Bonnet, Damien; Raimondi, Francesca

    2016-01-01

    To assess the impact of different protocols on radiation dose and image quality for paediatric coronary computed tomography (cCT). From January-2012 to June-2014, 140 children who underwent cCT on a 64-slice scanner were included. Two consecutive changes in imaging protocols were performed: 1) the use of adaptive statistical iterative reconstruction (ASIR); 2) the optimization of acquisition parameters. Effective dose (ED) was calculated by conversion of the dose-length product. Image quality was assessed as excellent, good or with significant artefacts. Patients were divided in three age groups: 0-4, 5-7 and 8-18 years. The use of ASIR combined to the adjustment of scan settings allowed a reduction in the median ED of 58 %, 82 % and 85 % in 0-4, 5-7 and 8-18 years group, respectively (7.3 ± 1.4 vs 3.1 ± 0.7 mSv, 5.5 ± 1.6 vs 1 ± 1.9 mSv and 5.3 ± 5.0 vs 0.8 ± 2.0 mSv, all p < 0,05). Prospective protocol was used in 51 % of children. The reduction in radiation dose was not associated with reduction in diagnostic image quality as assessed by the frequency of coronary segments with excellent or good image quality (88 %). cCT can be obtained at very low radiation doses in children using ASIR, and prospective acquisition with optimized imaging parameters. (orig.)

  4. Irradiation treatment for the protection and conservation of cultural heritage artefacts in Croatia

    International Nuclear Information System (INIS)

    Katusin-Razem, Branka; Razem, Dusan; Braun, Mario

    2009-01-01

    The application of irradiation treatment for the protection of cultural heritage artefacts in Croatia was made possible by the development of radiation processing procedures at the Radiation Chemistry and Dosimetry Laboratory of the Ruder Boskovic Institute. After the upgrading of the 60 Co gamma irradiation source in the panoramic irradiation facility in 1983 it became possible to perform both research and pilot plant-scale irradiations for sterilization, pasteurization and decontamination of various materials, including medical supplies, pharmaceuticals, cosmetics and foods, but also for disinfestation of cultural heritage artefects. The demand for irradiation treatment of cultural heritage objects has particularly increased as the increasing number of these objects, especially polychromic wooden sculptures, were requiring salvation, restauration and conservation as a consequence of direct and indirect damages inflicted to them during the war in Croatia, 1991-1995. The irradiation facility at the Ruder Boskovic Institute is briefly described and an account of its fifteen years' activities in the irradiation treatment of cultural heritage objects is given. Some case studies performed in cooperation with the Croatian Conservation Institute and other interested parties are presented, as well as some cases of protective and curative treatments for disinfestation and decontamination. International cooperations and activities are also mentioned.

  5. Irradiation treatment for the protection and conservation of cultural heritage artefacts in Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Katusin-Razem, Branka [Department of Chemistry, Ruder Boskovic Institute, Bijenicka cesta 54, P.O. Box 180, HR-10002 Zagreb (Croatia)], E-mail: brazem@irb.hr; Razem, Dusan [Department of Chemistry, Ruder Boskovic Institute, Bijenicka cesta 54, P.O. Box 180, HR-10002 Zagreb (Croatia); Braun, Mario [Croatian Conservation Institute, Zagreb (Croatia)

    2009-07-15

    The application of irradiation treatment for the protection of cultural heritage artefacts in Croatia was made possible by the development of radiation processing procedures at the Radiation Chemistry and Dosimetry Laboratory of the Ruder Boskovic Institute. After the upgrading of the {sup 60}Co gamma irradiation source in the panoramic irradiation facility in 1983 it became possible to perform both research and pilot plant-scale irradiations for sterilization, pasteurization and decontamination of various materials, including medical supplies, pharmaceuticals, cosmetics and foods, but also for disinfestation of cultural heritage artefects. The demand for irradiation treatment of cultural heritage objects has particularly increased as the increasing number of these objects, especially polychromic wooden sculptures, were requiring salvation, restauration and conservation as a consequence of direct and indirect damages inflicted to them during the war in Croatia, 1991-1995. The irradiation facility at the Ruder Boskovic Institute is briefly described and an account of its fifteen years' activities in the irradiation treatment of cultural heritage objects is given. Some case studies performed in cooperation with the Croatian Conservation Institute and other interested parties are presented, as well as some cases of protective and curative treatments for disinfestation and decontamination. International cooperations and activities are also mentioned.

  6. An intelligent despeckling method for swept source optical coherence tomography images of skin

    Science.gov (United States)

    Adabi, Saba; Mohebbikarkhoran, Hamed; Mehregan, Darius; Conforto, Silvia; Nasiriavanaki, Mohammadreza

    2017-03-01

    Optical Coherence Optical coherence tomography is a powerful high-resolution imaging method with a broad biomedical application. Nonetheless, OCT images suffer from a multiplicative artefacts so-called speckle, a result of coherent imaging of system. Digital filters become ubiquitous means for speckle reduction. Addressing the fact that there still a room for despeckling in OCT, we proposed an intelligent speckle reduction framework based on OCT tissue morphological, textural and optical features that through a trained network selects the winner filter in which adaptively suppress the speckle noise while preserve structural information of OCT signal. These parameters are calculated for different steps of the procedure to be used in designed Artificial Neural Network decider that select the best denoising technique for each segment of the image. Results of training shows the dominant filter is BM3D from the last category.

  7. Explaining reduction of pedestrian-motor vehicle crashes in Arkhangelsk, Russia, in 2005-2010.

    Science.gov (United States)

    Kudryavtsev, Alexander V; Nilssen, Odd; Lund, Johan; Grjibovski, Andrej M; Ytterstad, Børge

    2012-01-01

    To explain a reduction in pedestrian-motor vehicle crashes in Arkhangelsk, Russia, in 2005-2010. Retrospective ecological study. For 2005-2010, police data on pedestrian-motor vehicle crashes, traffic violations, and total motor vehicles (MVs) were combined with data on changes in national road traffic legislation and municipal road infrastructure. Negative binomial regression was used to investigate trends in monthly rates of pedestrian-motor vehicle crashes per total MVs and estimate changes in these rates per unit changes in the safety measures. During the 6 years, the police registered 2,565 pedestrian-motor vehicle crashes: 1,597 (62%) outside crosswalks, 766 (30%) on non-signalized crosswalks, and 202 (8%) on signalized crosswalks. Crash rates outside crosswalks and on signalized crosswalks decreased on average by 1.1% per month, whereas the crash rate on non-signalized crosswalks remained unchanged. Numbers of signalized and non-signalized crosswalks increased by 14 and 19%, respectively. Also, 10% of non-signalized crosswalks were combined with speed humps, and 4% with light-reflecting vertical signs. Pedestrian penalties for traffic violations increased 4-fold. Driver penalties for ignoring prohibiting signal and failure to give way to pedestrian on non-signalized crosswalk increased 7- and 8-fold, respectively. The rate of total registered drivers' traffic violations per total MVs decreased on average by 0.3% per month. All studied infrastructure and legislative measures had inverse associations with the rate of crashes outside crosswalks. The rate of crashes on signalized crosswalks showed inverse associations with related monetary penalties. The introduction of infrastructure and legislative measures is the most probable explanation of the reduction of pedestrian-motor vehicle crashes in Arkhangelsk. The overall reduction is due to decreases in rates of crashes outside crosswalks and on signalized crosswalks. No change was observed in the rate of

  8. Diagnosis diagrams for passing signals on an automatic block signaling railway section

    Science.gov (United States)

    Spunei, E.; Piroi, I.; Chioncel, C. P.; Piroi, F.

    2018-01-01

    This work presents a diagnosis method for railway traffic security installations. More specifically, the authors present a series of diagnosis charts for passing signals on a railway block equipped with an automatic block signaling installation. These charts are based on the exploitation electric schemes, and are subsequently used to develop a diagnosis software package. The thus developed software package contributes substantially to a reduction of failure detection and remedy for these types of installation faults. The use of the software package eliminates making wrong decisions in the fault detection process, decisions that may result in longer remedy times and, sometimes, to railway traffic events.

  9. Digital Signal Processing applied to Physical Signals

    CERN Document Server

    Alberto, Diego; Musa, L

    2011-01-01

    It is well known that many of the scientific and technological discoveries of the XXI century will depend on the capability of processing and understanding a huge quantity of data. With the advent of the digital era, a fully digital and automated treatment can be designed and performed. From data mining to data compression, from signal elaboration to noise reduction, a processing is essential to manage and enhance features of interest after every data acquisition (DAQ) session. In the near future, science will go towards interdisciplinary research. In this work there will be given an example of the application of signal processing to different fields of Physics from nuclear particle detectors to biomedical examinations. In Chapter 1 a brief description of the collaborations that allowed this thesis is given, together with a list of the publications co-produced by the author in these three years. The most important notations, definitions and acronyms used in the work are also provided. In Chapter 2, the last r...

  10. Nanoparticles of Sr(OH)2: synthesis in homogeneous phase at low temperature and application for cultural heritage artefacts

    International Nuclear Information System (INIS)

    Ciliberto, E.; Condorelli, G.G.; La Delfa, S.; Viscuso, E.

    2008-01-01

    This paper concerns the synthesis and the characterization of nanometer particles of Sr(OH) 2 , a moderately high water soluble hydroxide (Ksp=3.2 x 10 -4 at 25 C). The reported process yields strontium hydroxide nanoparticles starting from low cost raw materials in aqueous medium (homogeneous phase) at low temperature (below 100 C) by chemical precipitation from salt solutions, involving very simple operational steps and avoiding the use of organic solvents. Observations by X-ray diffraction (XRD), scanning electron microscopy (SEM), electron dispersive X-Ray (EDX) and Fourier transform infrared spectroscopy (FTIR) indicate that the particles are well-crystallized and have nanometer dimensions (∝30 nm in diameter). Moreover, experimental evidence shows the potential use of this material for the protection and the consolidation of wall paintings (frescoes), paper, stone, wood and other artistic artefacts. (orig.)

  11. Video manometry of the sphincter of Oddi: a new aid for interpreting manometric tracings and excluding manometric artefacts

    DEFF Research Database (Denmark)

    Madácsy, L; Middelfart, H V; Matzen, Peter

    2000-01-01

    was to develop a new method sphincter of Oddi video manometry-based on simultaneous ESOM and real-time endoscopic image analysis, and to investigate the usefulness of video manometry for detecting manometric artefacts during ESOM. PATIENTS AND METHODS: Seven consecutive patients who had undergone cholecystectomy...... and were referred with a suspicion of sphincter of Oddi dysfunction were investigated. Sphincter of Oddi pressure and endoscopic images (20 frames/s) were recorded simultaneously on a Synectics PC Polygraf computer system with a time-correlated basis, and then compared. RESULTS: On ESOM, 69 sphincter......, or retching, were also easily recognized using simultaneous ESOM and real-time endoscopic image analysis. CONCLUSIONS: Video manometry of the sphincter of Oddi is a promising new method for improving the analysis and documentation of ESOM tracings. It has several advantages over the conventional technique...

  12. Minimum Mean-Square Error Single-Channel Signal Estimation

    DEFF Research Database (Denmark)

    Beierholm, Thomas

    2008-01-01

    This topic of this thesis is MMSE signal estimation for hearing aids when only one microphone is available. The research is relevant for noise reduction systems in hearing aids. To fully benefit from the amplification provided by a hearing aid, noise reduction functionality is important as hearin...... algorithm. Although performance of the two algorithms is found comparable then the particle filter algorithm is doing a much better job tracking the noise.......-impaired persons in some noisy situations need a higher signal to noise ratio for speech to be intelligible when compared to normal-hearing persons. In this thesis two different methods to approach the MMSE signal estimation problem is examined. The methods differ in the way that models for the signal and noise...... inference is performed by particle filtering. The speech model is a time-varying auto-regressive model reparameterized by formant frequencies and bandwidths. The noise is assumed non-stationary and white. Compared to the case of using the AR coefficients directly then it is found very beneficial to perform...

  13. The artefacts of radiochromic film dosimetry with flatbed scanners and their causation by light scattering from radiation-induced polymers

    International Nuclear Information System (INIS)

    Schoenfeld, Andreas A; Poppinga, Daniela; Poppe, Bjoern; Harder, Dietrich; Doerner, Karl-Joachim

    2014-01-01

    Optical experiments and theoretical considerations have been undertaken in order to understand the causes of the ‘orientation effect’ and the ‘parabola effect’, the artefacts impairing the desired light absorption measurement on radiochromic EBT3 films with flatbed scanners. EBT3 films exposed to doses up to 20.9 Gy were scanned with an Epson Expression 10000XL flatbed scanner in landscape and portrait orientation. The horizontally and vertically polarized light components of the scanner were determined, and another Epson Expression 10000XL flatbed scanner was disassembled to examine its optical components. The optical properties of exposed and unexposed EBT3 films were studied with incident polarized and unpolarized white light, and the transmitted red light was investigated for its polarization and scattering properties including the distribution of the scattering angles. Neutral density filters were studied for comparison. Guidance was sought from the theory of light scattering from rod-like macromolecular structures. The drastic dose-dependent variation of the transmitted total light current as function of the orientation of front and rear polarizers, interpreted by light scattering theory, shows that the radiation-induced polymerization of the monomers of EBT3 films produces light scattering oscillators preferably polarized at right angles with the coating direction of the film. The directional distribution of the scattered light is partly anisotropic, with a preferred scattering plane at right angles with the coating direction, indicating light scattering from stacks of coherently vibrating oscillators piled up along the monomer crystals. The polyester carrier film also participates in these effects. The ‘orientation’ and ‘parabola’ artefacts due to flatbed scanning of radiochromic films can be explained by the interaction of the polarization-dependent and anisotropic light scattering from exposed and unexposed EBT3 films with the quantitative

  14. Reduction of Nup107 attenuates the growth factor signaling in the senescent cells

    International Nuclear Information System (INIS)

    Kim, Sung Young; Kang, Hyun Tae; Choi, Hae Ri; Park, Sang Chul

    2010-01-01

    Research highlights: → Decreased expression of Nup107 in aged cells and organs. → Depletion of Nup107 results in impaired nuclear translocation of p-ERK. → Depletion of Nup107 affects downstream effectors of ERK signaling. → Depletion of Nup107 inhibits cell proliferation of oligodendroglioma cells. -- Abstract: Hypo-responsiveness to growth factors is a fundamental feature of cellular senescence. In this study, we found markedly decreased level of Nup107, a key scaffold protein in nuclear pore complex assembly, in senescent human diploid fibroblasts as well as in organs of aged mice. Depletion of Nup107 by specific siRNA in young human diploid fibroblasts prevented the effective nuclear translocation of phosphorylated extracellular signal-regulated kinase (ERK) following epidermal growth factor (EGF) stimulation, and decreased the expression of c-Fos in consequence. The disturbances in ERK signaling in Nup107 depleted cells closely mirror the similar changes in senescent cells. Knockdown of Nup107 in anaplastic oligodendroglioma cells caused cell death, rather than growth retardation, indicating a greater sensitivity to Nup107 depletion in cancer cells than in normal cells. These findings support the notion that Nup107 may contribute significantly to the regulation of cell fate in aged and transformed cells by modulating nuclear trafficking of signal molecules.

  15. Reduction of Nup107 attenuates the growth factor signaling in the senescent cells

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Young; Kang, Hyun Tae; Choi, Hae Ri [Department of Biochemistry and Molecular Biology, Aging and Apoptosis Research Center, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of); Park, Sang Chul, E-mail: scpark@snu.ac.kr [Department of Biochemistry and Molecular Biology, Aging and Apoptosis Research Center, Seoul National University College of Medicine, Seoul 110-799 (Korea, Republic of)

    2010-10-08

    Research highlights: {yields} Decreased expression of Nup107 in aged cells and organs. {yields} Depletion of Nup107 results in impaired nuclear translocation of p-ERK. {yields} Depletion of Nup107 affects downstream effectors of ERK signaling. {yields} Depletion of Nup107 inhibits cell proliferation of oligodendroglioma cells. -- Abstract: Hypo-responsiveness to growth factors is a fundamental feature of cellular senescence. In this study, we found markedly decreased level of Nup107, a key scaffold protein in nuclear pore complex assembly, in senescent human diploid fibroblasts as well as in organs of aged mice. Depletion of Nup107 by specific siRNA in young human diploid fibroblasts prevented the effective nuclear translocation of phosphorylated extracellular signal-regulated kinase (ERK) following epidermal growth factor (EGF) stimulation, and decreased the expression of c-Fos in consequence. The disturbances in ERK signaling in Nup107 depleted cells closely mirror the similar changes in senescent cells. Knockdown of Nup107 in anaplastic oligodendroglioma cells caused cell death, rather than growth retardation, indicating a greater sensitivity to Nup107 depletion in cancer cells than in normal cells. These findings support the notion that Nup107 may contribute significantly to the regulation of cell fate in aged and transformed cells by modulating nuclear trafficking of signal molecules.

  16. Characterization and reduction of motion artifacts in photoplethysmographic signals from a wrist-worn device

    NARCIS (Netherlands)

    Tauţan, A.M.; Young, A.; Wentink, E.; Wieringa, F.P.

    2015-01-01

    Methods for analyzing various motion artifacts in photoplethysmography (PPG) signals, recorded by a wristworn device are reported. The analysis looks both at intrinsic PPG signal properties, through standard deviation, skew and kurtosis, but also at its relationship to five possible motion reference

  17. A retrospective, semi-quantitative image quality analysis of cone beam computed tomography (CBCT) and MSCT in the diagnosis of distal radius fractures

    Energy Technology Data Exchange (ETDEWEB)

    Lang, H.; Neubauer, J.; Fritz, B.; Spira, E.M.; Strube, J.; Langer, M.; Kotter, E. [University Medical Center Freiburg, Department of Radiology, Freiburg (Germany)

    2016-12-15

    To compare image quality and diagnostic validity of CBCT and MSCT for distal radius fractures. 35 CBCT and 33 MSCT scans were retrospectively reviewed with a visual grading scale regarding the depiction of cortical bone, trabecular bone, articular surfaces, and soft tissue. The extent and type of artefacts was analyzed. Agreement on AO classification and measurement of cortical disruption and length of the fracture gap was determined. Fracture reduction was evaluated in post-treatment x-rays. Statistical analysis was performed with visual grading characteristics (VGC), chi square tests, and Kendall's coefficient of concordance. CBCT performed significantly worse for cortical bone, articular surfaces, and especially soft tissue. Trabecular bone showed no significant difference. Significantly more CBCT images showed artefacts. Physics-based artefacts were the most common. CBCT scans also showed motion artefacts. There was no significant difference in agreement on AO classification. The agreement on measurements was substantial for both modalities. Slightly more fractures that had undergone MSCT imaging showed adequate reduction. This initial study of an orthopaedic extremity CBCT scanner showed that the image quality of a CBCT scanner remains inferior for most structures at standard settings. Diagnostic validity of both modalities for distal radius fractures seems similar. (orig.)

  18. Defective chemokine signal integration in leukocytes lacking activator of G protein signaling 3 (AGS3).

    Science.gov (United States)

    Branham-O'Connor, Melissa; Robichaux, William G; Zhang, Xian-Kui; Cho, Hyeseon; Kehrl, John H; Lanier, Stephen M; Blumer, Joe B

    2014-04-11

    Activator of G-protein signaling 3 (AGS3, gene name G-protein signaling modulator-1, Gpsm1), an accessory protein for G-protein signaling, has functional roles in the kidney and CNS. Here we show that AGS3 is expressed in spleen, thymus, and bone marrow-derived dendritic cells, and is up-regulated upon leukocyte activation. We explored the role of AGS3 in immune cell function by characterizing chemokine receptor signaling in leukocytes from mice lacking AGS3. No obvious differences in lymphocyte subsets were observed. Interestingly, however, AGS3-null B and T lymphocytes and bone marrow-derived dendritic cells exhibited significant chemotactic defects as well as reductions in chemokine-stimulated calcium mobilization and altered ERK and Akt activation. These studies indicate a role for AGS3 in the regulation of G-protein signaling in the immune system, providing unexpected venues for the potential development of therapeutic agents that modulate immune function by targeting these regulatory mechanisms.

  19. Signal Enhancement with Variable Span Linear Filters

    DEFF Research Database (Denmark)

    Benesty, Jacob; Christensen, Mads Græsbøll; Jensen, Jesper Rindom

    . Variable span filters combine the ideas of optimal linear filters with those of subspace methods, as they involve the joint diagonalization of the correlation matrices of the desired signal and the noise. The book shows how some well-known filter designs, e.g. the minimum distortion, maximum signal...... the time and STFT domains, and, lastly, in time-domain binaural enhancement. In these contexts, the properties of these filters are analyzed in terms of their noise reduction capabilities and desired signal distortion, and the analyses are validated and further explored in simulations....

  20. Learning-induced uncertainty reduction in perceptual decisions is task-dependent

    Directory of Open Access Journals (Sweden)

    Feitong eYang

    2014-05-01

    Full Text Available Perceptual decision making in which decisions are reached primarily from extracting and evaluating sensory information requires close interactions between the sensory system and decision-related networks in the brain. Uncertainty pervades every aspect of this process and can be considered related to either the stimulus signal or decision criterion. Here, we investigated the learning-induced reduction of both the signal and criterion uncertainty in two perceptual decision tasks based on two Glass pattern stimulus sets. This was achieved by manipulating spiral angle and signal level of radial and concentric Glass patterns. The behavioral results showed that the participants trained with a task based on criterion comparison improved their categorization accuracy for both tasks, whereas the participants who were trained on a task based on signal detection improved their categorization accuracy only on their trained task. We fitted the behavioral data with a computational model that can dissociate the contribution of the signal and criterion uncertainties. The modeling results indicated that the participants trained on the criterion comparison task reduced both the criterion and signal uncertainty. By contrast, the participants who were trained on the signal detection task only reduced their signal uncertainty after training. Our results suggest that the signal uncertainty can be resolved by training participants to extract signals from noisy environments and to discriminate between clear signals, which are evidenced by reduced perception variance after both training procedures. Conversely, the criterion uncertainty can only be resolved by the training of fine discrimination. These findings demonstrate that uncertainty in perceptual decision-making can be reduced with training but that the reduction of different types of uncertainty is task-dependent.

  1. Statistical optimisation techniques in fatigue signal editing problem

    International Nuclear Information System (INIS)

    Nopiah, Z. M.; Osman, M. H.; Baharin, N.; Abdullah, S.

    2015-01-01

    Success in fatigue signal editing is determined by the level of length reduction without compromising statistical constraints. A great reduction rate can be achieved by removing small amplitude cycles from the recorded signal. The long recorded signal sometimes renders the cycle-to-cycle editing process daunting. This has encouraged researchers to focus on the segment-based approach. This paper discusses joint application of the Running Damage Extraction (RDE) technique and single constrained Genetic Algorithm (GA) in fatigue signal editing optimisation.. In the first section, the RDE technique is used to restructure and summarise the fatigue strain. This technique combines the overlapping window and fatigue strain-life models. It is designed to identify and isolate the fatigue events that exist in the variable amplitude strain data into different segments whereby the retention of statistical parameters and the vibration energy are considered. In the second section, the fatigue data editing problem is formulated as a constrained single optimisation problem that can be solved using GA method. The GA produces the shortest edited fatigue signal by selecting appropriate segments from a pool of labelling segments. Challenges arise due to constraints on the segment selection by deviation level over three signal properties, namely cumulative fatigue damage, root mean square and kurtosis values. Experimental results over several case studies show that the idea of solving fatigue signal editing within a framework of optimisation is effective and automatic, and that the GA is robust for constrained segment selection

  2. Statistical optimisation techniques in fatigue signal editing problem

    Energy Technology Data Exchange (ETDEWEB)

    Nopiah, Z. M.; Osman, M. H. [Fundamental Engineering Studies Unit Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM (Malaysia); Baharin, N.; Abdullah, S. [Department of Mechanical and Materials Engineering Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, 43600 UKM (Malaysia)

    2015-02-03

    Success in fatigue signal editing is determined by the level of length reduction without compromising statistical constraints. A great reduction rate can be achieved by removing small amplitude cycles from the recorded signal. The long recorded signal sometimes renders the cycle-to-cycle editing process daunting. This has encouraged researchers to focus on the segment-based approach. This paper discusses joint application of the Running Damage Extraction (RDE) technique and single constrained Genetic Algorithm (GA) in fatigue signal editing optimisation.. In the first section, the RDE technique is used to restructure and summarise the fatigue strain. This technique combines the overlapping window and fatigue strain-life models. It is designed to identify and isolate the fatigue events that exist in the variable amplitude strain data into different segments whereby the retention of statistical parameters and the vibration energy are considered. In the second section, the fatigue data editing problem is formulated as a constrained single optimisation problem that can be solved using GA method. The GA produces the shortest edited fatigue signal by selecting appropriate segments from a pool of labelling segments. Challenges arise due to constraints on the segment selection by deviation level over three signal properties, namely cumulative fatigue damage, root mean square and kurtosis values. Experimental results over several case studies show that the idea of solving fatigue signal editing within a framework of optimisation is effective and automatic, and that the GA is robust for constrained segment selection.

  3. Reduction of emission level in approach signals of greater mouse-eared bats (Myotis myotis): No evidence for a closed loop control system for intensity compensation.

    Science.gov (United States)

    Budenz, Tobias; Denzinger, Annette; Schnitzler, Hans-Ulrich

    2018-01-01

    Bats lower the emission SPL when approaching a target. The SPL reduction has been explained by intensity compensation which implies that bats adjust the emission SPL to perceive the retuning echoes at the same level. For a better understanding of this control mechanism we recorded the echolocation signals of four Myotis myotis with an onboard microphone when foraging in the passive mode for rustling mealworms offered in two feeding dishes with different target strength, and determined the reduction rate for the emission SPL and the increase rate for the SPL of the returning echoes. When approaching the dish with higher target strength bats started the reduction of the emission SPL at a larger reaction distance (1.05 ± 0.21 m) and approached it with a lower reduction rate of 7.2 dB/halving of distance (hd), thus producing a change of echo rate at the ears of + 4 dB/hd. At the weaker target reaction distance was shorter (0.71 ± 0.24 m) and the reduction rate (9.1 dB/hd) was higher, producing a change of echo rate of-1.2 dB/hd. Independent of dish type, bats lowered the emission SPL by about 26 dB on average. In one bat where the echo SPL from both targets could be measured, the reduction of emission SPL was triggered when the echo SPL surpassed a similar threshold value around 41-42 dB. Echo SPL was not adjusted at a constant value indicating that Myotis myotis and most likely all other bats do not use a closed loop system for intensity compensation when approaching a target of interest. We propose that bats lower the emission SPL to adjust the SPL of the perceived pulse-echo-pairs to the optimal auditory range for the processing of range information and hypothesize that bats use flow field information not only to control the reduction of the approach speed to the target but also to control the reduction of emission SPL.

  4. Noise reduction in the beam current monitor

    International Nuclear Information System (INIS)

    Arai, Shigeaki.

    1982-02-01

    A simple noise reduction system using a pulse transformer and a pair of L C low pass filters has been introduced to the beam current monitor of a current transformer type at the INS electron linac. With this system, the pick-up noise has been reduced to be 1% of the noise without noise reduction. Signal deformation caused by this system is relatively small and the beam current pulse down to 20 mA is successfully monitored in the actual accelerator operation. (author)

  5. Data reduction, radial velocities and stellar parameters from spectra in the very low signal-to-noise domain

    Science.gov (United States)

    Malavolta, Luca

    2013-10-01

    Large astronomical facilities usually provide data reduction pipeline designed to deliver ready-to-use scientific data, and too often as- tronomers are relying on this to avoid the most difficult part of an astronomer job Standard data reduction pipelines however are usu- ally designed and tested to have good performance on data with av- erage Signal to Noise Ratio (SNR) data, and the issues that are related with the reduction of data in the very low SNR domain are not taken int account properly. As a result, informations in data with low SNR are not optimally exploited. During the last decade our group has collected thousands of spec- tra using the GIRAFFE spectrograph at Very Large Telescope (Chile) of the European Southern Observatory (ESO) to determine the ge- ometrical distance and dynamical state of several Galactic Globular Clusters but ultimately the analysis has been hampered by system- atics in data reduction, calibration and radial velocity measurements. Moreover these data has never been exploited to get other informa- tions like temperature and metallicity of stars, because considered too noisy for these kind of analyses. In this thesis we focus our attention on data reduction and analysis of spectra with very low SNR. The dataset we analyze in this thesis comprises 7250 spectra for 2771 stars of the Globular Cluster M 4 (NGC 6121) in the wavelength region 5145-5360Å obtained with GIRAFFE. Stars from the upper Red Giant Branch down to the Main Sequence have been observed in very different conditions, including nights close to full moon, and reaching SNR - 10 for many spectra in the dataset. We will first review the basic steps of data reduction and spec- tral extraction, adapting techniques well tested in other field (like photometry) but still under-developed in spectroscopy. We improve the wavelength dispersion solution and the correction of radial veloc- ity shift between day-time calibrations and science observations by following a completely

  6. Extended use of electronic health records by primary care physicians: Does the electronic health record artefact matter?

    Science.gov (United States)

    Raymond, Louis; Paré, Guy; Marchand, Marie

    2017-04-01

    The deployment of electronic health record systems is deemed to play a decisive role in the transformations currently being implemented in primary care medical practices. This study aims to characterize electronic health record systems from the perspective of family physicians. To achieve this goal, we conducted a survey of physicians practising in private clinics located in Quebec, Canada. We used valid responses from 331 respondents who were found to be representative of the larger population. Data provided by the physicians using the top three electronic health record software products were analysed in order to obtain statistically adequate sub-sample sizes. Significant differences were observed among the three products with regard to their functional capability. The extent to which each of the electronic health record functionalities are used by physicians also varied significantly. Our results confirm that the electronic health record artefact 'does matter', its clinical functionalities explaining why certain physicians make more extended use of their system than others.

  7. Respiratory Information Extraction from Electrocardiogram Signals

    KAUST Repository

    Amin, Gamal El Din Fathy

    2010-12-01

    The Electrocardiogram (ECG) is a tool measuring the electrical activity of the heart, and it is extensively used for diagnosis and monitoring of heart diseases. The ECG signal reflects not only the heart activity but also many other physiological processes. The respiratory activity is a prominent process that affects the ECG signal due to the close proximity of the heart and the lungs. In this thesis, several methods for the extraction of respiratory process information from the ECG signal are presented. These methods allow an estimation of the lung volume and the lung pressure from the ECG signal. The potential benefit of this is to eliminate the corresponding sensors used to measure the respiration activity. A reduction of the number of sensors connected to patients will increase patients’ comfort and reduce the costs associated with healthcare. As a further result, the efficiency of diagnosing respirational disorders will increase since the respiration activity can be monitored with a common, widely available method. The developed methods can also improve the detection of respirational disorders that occur while patients are sleeping. Such disorders are commonly diagnosed in sleeping laboratories where the patients are connected to a number of different sensors. Any reduction of these sensors will result in a more natural sleeping environment for the patients and hence a higher sensitivity of the diagnosis.

  8. Refinement of clinical X-ray computed tomography (CT) scans containing metal implants.

    Science.gov (United States)

    Treece, Graham

    2017-03-01

    X-ray computed tomography (CT) data contains artefacts from many sources, with sufficient prominence to affect diagnostic utility when metal is present in the scans. These artefacts can be reduced, usually by the removal and in-filling of any sinogram data which has been affected by metal, and several such techniques have been proposed. Most of them are prone to introducing new artefacts into the CT data or may take a long time to correct the data. It is the purpose of this paper to introduce a new technique which is fast, yet can effectively remove most artefacts without introducing significant new ones. The new metal artefact reduction technique (RMAR) consists of an iterative refinement of the CT data by alternately forward- and back-projecting the part of the reconstruction near to metal. The forward-projection is corrected by making use of a prior derived from the reconstructed data which is independently estimated for each projection angle, and smoothed using a newly developed Bitonic filter. The new technique is compared with previously published (LI, NMAR, MDT) and commercial (O-MAR, IMAR) alternatives, quantitatively on phantom data, and qualitatively on a selection of clinical scans, mostly of the hip. The phantom data is from two recently published studies, enabling direct comparison with previous results. The results show an increased reduction of artefacts on the four phantom data sets tested. On two of the phantom data sets, RMAR is significantly better (pCT data, RMAR can correct each image in 3-8s, which is more than one hundred times faster than MDT. The new technique is demonstrated to have performance at least as good as MDT, with both out-performing other approaches. However, it is much faster then the latter technique, and shows better preservation of data very close to metal. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Modelling of Signal - Level Crossing System

    Directory of Open Access Journals (Sweden)

    Daniel Novak

    2006-01-01

    Full Text Available The author presents an object-oriented model of a railway level-crossing system created for the purpose of functional requirements specification. Unified Modelling Language (UML, version 1.4, which enables specification, visualisation, construction and documentation of software system artefacts, was used. The main attention was paid to analysis and design phases. The former phase resulted in creation of use case diagrams and sequential diagrams, the latter in creation of class/object diagrams and statechart diagrams.

  10. Advanced techniques for digital angiography of the heart

    International Nuclear Information System (INIS)

    Hoehne, K.H.; Obermoeller, U.; Riemer, M.; Witte, G.

    1987-01-01

    Digital angiography is widely considered as being simply a method in which images taken at different times are subtracted from each other. This paper presents some techniques which are performed in the frequency domain after the application of the Fourier Transform. Nonselective bypass angiograms and intravenous ventriculograms are taken as examples to show that simple procedures utilizing these techniques exhibit the advantages of improved signal to noise ratio in the subtraction images, reduction of motion artefacts, easy application of phase-synchronous subtraction, integration and quantitative visualization of blood propagation. Furthermore it is shown that the storage of the angiographic image sequence as Fourier-coefficients leads to data compression and convenient data access in an image database. (Auth.)

  11. Septal penetration correction in I-131 imaging following thyroid cancer treatment

    Science.gov (United States)

    Barrack, Fiona; Scuffham, James; McQuaid, Sarah

    2018-04-01

    Whole body gamma camera images acquired after I-131 treatment for thyroid cancer can suffer from collimator septal penetration artefacts because of the high energy of the gamma photons. This results in the appearance of ‘spoke’ artefacts, emanating from regions of high activity concentration, caused by the non-isotropic attenuation of the collimator. Deconvolution has the potential to reduce such artefacts, by taking into account the non-Gaussian point-spread-function (PSF) of the system. A Richardson–Lucy deconvolution algorithm, with and without prior scatter-correction was tested as a method of reducing septal penetration in planar gamma camera images. Phantom images (hot spheres within a warm background) were acquired and deconvolution using a measured PSF was applied. The results were evaluated through region-of-interest and line profile analysis to determine the success of artefact reduction and the optimal number of deconvolution iterations and damping parameter (λ). Without scatter-correction, the optimal results were obtained with 15 iterations and λ  =  0.01, with the counts in the spokes reduced to 20% of the original value, indicating a substantial decrease in their prominence. When a triple-energy-window scatter-correction was applied prior to deconvolution, the optimal results were obtained with six iterations and λ  =  0.02, which reduced the spoke counts to 3% of the original value. The prior application of scatter-correction therefore produced the best results, with a marked change in the appearance of the images. The optimal settings were then applied to six patient datasets, to demonstrate its utility in the clinical setting. In all datasets, spoke artefacts were substantially reduced after the application of scatter-correction and deconvolution, with the mean spoke count being reduced to 10% of the original value. This indicates that deconvolution is a promising technique for septal penetration artefact reduction that

  12. Digital signal display board design: A knowledge based study

    International Nuclear Information System (INIS)

    Chaitanya, V. Sree Krishna; Rao, C. Raghavendra

    2007-01-01

    The digital signal display board is assumed to be composed of picture tubes for the purpose of displaying characters. The signal board with the picture tubes constitutes an Information System. A methodology for obtaining the discrimable matrix or table (more decisive attributes) and knowledge reduction for the above information system is proposed

  13. Noise reduction with complex bilateral filter.

    Science.gov (United States)

    Matsumoto, Mitsuharu

    2017-12-01

    This study introduces a noise reduction technique that uses a complex bilateral filter. A bilateral filter is a nonlinear filter originally developed for images that can reduce noise while preserving edge information. It is an attractive filter and has been used in many applications in image processing. When it is applied to an acoustical signal, small-amplitude noise is reduced while the speech signal is preserved. However, a bilateral filter cannot handle noise with relatively large amplitudes owing to its innate characteristics. In this study, the noisy signal is transformed into the time-frequency domain and the filter is improved to handle complex spectra. The high-amplitude noise is reduced in the time-frequency domain via the proposed filter. The features and the potential of the proposed filter are also confirmed through experiments.

  14. A Dictionary Learning Approach for Signal Sampling in Task-Based fMRI for Reduction of Big Data

    Science.gov (United States)

    Ge, Bao; Li, Xiang; Jiang, Xi; Sun, Yifei; Liu, Tianming

    2018-01-01

    The exponential growth of fMRI big data offers researchers an unprecedented opportunity to explore functional brain networks. However, this opportunity has not been fully explored yet due to the lack of effective and efficient tools for handling such fMRI big data. One major challenge is that computing capabilities still lag behind the growth of large-scale fMRI databases, e.g., it takes many days to perform dictionary learning and sparse coding of whole-brain fMRI data for an fMRI database of average size. Therefore, how to reduce the data size but without losing important information becomes a more and more pressing issue. To address this problem, we propose a signal sampling approach for significant fMRI data reduction before performing structurally-guided dictionary learning and sparse coding of whole brain's fMRI data. We compared the proposed structurally guided sampling method with no sampling, random sampling and uniform sampling schemes, and experiments on the Human Connectome Project (HCP) task fMRI data demonstrated that the proposed method can achieve more than 15 times speed-up without sacrificing the accuracy in identifying task-evoked functional brain networks. PMID:29706880

  15. A Dictionary Learning Approach for Signal Sampling in Task-Based fMRI for Reduction of Big Data.

    Science.gov (United States)

    Ge, Bao; Li, Xiang; Jiang, Xi; Sun, Yifei; Liu, Tianming

    2018-01-01

    The exponential growth of fMRI big data offers researchers an unprecedented opportunity to explore functional brain networks. However, this opportunity has not been fully explored yet due to the lack of effective and efficient tools for handling such fMRI big data. One major challenge is that computing capabilities still lag behind the growth of large-scale fMRI databases, e.g., it takes many days to perform dictionary learning and sparse coding of whole-brain fMRI data for an fMRI database of average size. Therefore, how to reduce the data size but without losing important information becomes a more and more pressing issue. To address this problem, we propose a signal sampling approach for significant fMRI data reduction before performing structurally-guided dictionary learning and sparse coding of whole brain's fMRI data. We compared the proposed structurally guided sampling method with no sampling, random sampling and uniform sampling schemes, and experiments on the Human Connectome Project (HCP) task fMRI data demonstrated that the proposed method can achieve more than 15 times speed-up without sacrificing the accuracy in identifying task-evoked functional brain networks.

  16. Measurement of MOSFET LF Noise Under Large Signal RF Excitation

    NARCIS (Netherlands)

    van der Wel, A.P.; Klumperink, Eric A.M.; Nauta, Bram

    A new measurement technique is presented that allows measurement of MOSFET LF noise under large signal RF excitation. Measurements indicate that MOSFETS exhibit a reduction in LF noise when they are cycled from inversion to accummulation and that this reduction does not depend on the frequency of

  17. Nanoparticles of Sr(OH){sub 2}: synthesis in homogeneous phase at low temperature and application for cultural heritage artefacts

    Energy Technology Data Exchange (ETDEWEB)

    Ciliberto, E.; Condorelli, G.G.; La Delfa, S.; Viscuso, E. [Universita di Catania, Dipartimento di Scienze Chimiche, Catania (Italy)

    2008-07-15

    This paper concerns the synthesis and the characterization of nanometer particles of Sr(OH){sub 2}, a moderately high water soluble hydroxide (Ksp=3.2 x 10{sup -4} at 25 C). The reported process yields strontium hydroxide nanoparticles starting from low cost raw materials in aqueous medium (homogeneous phase) at low temperature (below 100 C) by chemical precipitation from salt solutions, involving very simple operational steps and avoiding the use of organic solvents. Observations by X-ray diffraction (XRD), scanning electron microscopy (SEM), electron dispersive X-Ray (EDX) and Fourier transform infrared spectroscopy (FTIR) indicate that the particles are well-crystallized and have nanometer dimensions ({proportional_to}30 nm in diameter). Moreover, experimental evidence shows the potential use of this material for the protection and the consolidation of wall paintings (frescoes), paper, stone, wood and other artistic artefacts. (orig.)

  18. Front-end data reduction of diagnostic signals by real-time digital filtering

    International Nuclear Information System (INIS)

    Zasche, D.; Fahrbach, H.U.; Harmeyer, E.

    1984-01-01

    Diagnostic measurements on a fusion plasma with high resolution in space, time and signal amplitude involve handling large amounts of data. In the design of the soft-X-ray pinhole camera diagnostic for JET (100 detectors in 2 cameras) a new approach to this problem was found. The analogue-to-digital conversion is performed continuously at the highest sample rate of 200 kHz, lower sample rates (10 kHz, 1 kHz, 100 Hz) are obtained by real-time digital filters which calculate weighted averages over consecutive samples and are undersampled at their outputs to reduce the data rate. At any time, the signals from all detectors are available at all possible data rates in ring buffers. The appropriate data rate can always be recorded on demand. (author)

  19. Noise reduction in binaural hearing aids : Analyzing the benefit over monaural systems

    NARCIS (Netherlands)

    Srinivasan, S.

    2008-01-01

    Binaural beamforming using signals from both left and right hearing aids offers greater potential for noise reduction than using signals from a single aid. However, wireless transmission of data imposes power constraints. Since most modern hearing aids have multiple microphones and are capable of

  20. Statistical-uncertainty-based adaptive filtering of lidar signals

    International Nuclear Information System (INIS)

    Fuehrer, P. L.; Friehe, C. A.; Hristov, T. S.; Cooper, D. I.; Eichinger, W. E.

    2000-01-01

    An adaptive filter signal processing technique is developed to overcome the problem of Raman lidar water-vapor mixing ratio (the ratio of the water-vapor density to the dry-air density) with a highly variable statistical uncertainty that increases with decreasing photomultiplier-tube signal strength and masks the true desired water-vapor structure. The technique, applied to horizontal scans, assumes only statistical horizontal homogeneity. The result is a variable spatial resolution water-vapor signal with a constant variance out to a range limit set by a specified signal-to-noise ratio. The technique was applied to Raman water-vapor lidar data obtained at a coastal pier site together with in situ instruments located 320 m from the lidar. The micrometerological humidity data were used to calibrate the ratio of the lidar gains of the H 2 O and the N 2 photomultiplier tubes and set the water-vapor mixing ratio variance for the adaptive filter. For the coastal experiment the effective limit of the lidar range was found to be approximately 200 m for a maximum noise-to-signal variance ratio of 0.1 with the implemented data-reduction procedure. The technique can be adapted to off-horizontal scans with a small reduction in the constraints and is also applicable to other remote-sensing devices that exhibit the same inherent range-dependent signal-to-noise ratio problem. (c) 2000 Optical Society of America

  1. Evaluation of Magnetic Resonance Imaging-Compatible Needles and Interactive Sequences for Musculoskeletal Interventions Using an Open High-Field Magnetic Resonance Imaging Scanner

    International Nuclear Information System (INIS)

    Wonneberger, Uta; Schnackenburg, Bernhard; Streitparth, Florian; Walter, Thula; Rump, Jens; Teichgraeber, Ulf K. M.

    2010-01-01

    In this article, we study in vitro evaluation of needle artefacts and image quality for musculoskeletal laser-interventions in an open high-field magnetic resonance imaging (MRI) scanner at 1.0T with vertical field orientation. Five commercially available MRI-compatible puncture needles were assessed based on artefact characteristics in a CuSO4 phantom (0.1%) and in human cadaveric lumbar spines. First, six different interventional sequences were evaluated with varying needle orientation to the main magnetic field B0 (0 o to 90 o ) in a sequence test. Artefact width, needle-tip error, and contrast-to-noise ratio (CNR) were calculated. Second, a gradient-echo sequence used for thermometric monitoring was assessed and in varying echo times, artefact width, tip error, and signal-to-noise ratio (SNR) were measured. Artefact width and needle-tip error correlated with needle material, instrument orientation to B0, and sequence type. Fast spin-echo sequences produced the smallest needle artefacts for all needles, except for the carbon fibre needle (width o to B0. Overall, the proton density-weighted spin-echo sequences had the best CNR (CNR Muscle/Needle >16.8). Concerning the thermometric gradient echo sequence, artefacts remained <5 mm, and the SNR reached its maximum at an echo time of 15 ms. If needle materials and sequences are accordingly combined, guidance and monitoring of musculoskeletal laser interventions may be feasible in a vertical magnetic field at 1.0T.

  2. Diversity combining in laser Doppler vibrometry for improved signal reliability

    International Nuclear Information System (INIS)

    Dräbenstedt, Alexander

    2014-01-01

    Because of the speckle nature of the light reflected from rough surfaces the signal quality of a vibrometer suffers from varying signal power. Deep signal outages manifest themselves as noise bursts and spikes in the demodulated velocity signal. Here we show that the signal quality of a single point vibrometer can be substantially improved by diversity reception. This concept is widely used in RF communication and can be transferred into optical interferometry. When two statistically independent measurement channels are available which measure the same motion on the same spot, the probability for both channels to see a signal drop-out at the same time is very low. We built a prototype instrument that uses polarization diversity to constitute two independent reception channels that are separately demodulated into velocity signals. Send and receive beams go through different parts of the aperture so that the beams can be spatially separated. The two velocity channels are mixed into one more reliable signal by a PC program in real time with the help of the signal power information. An algorithm has been developed that ensures a mixing of two or more channels with minimum resulting variance. The combination algorithm delivers also an equivalent signal power for the combined signal. The combined signal lacks the vast majority of spikes that are present in the raw signals and it extracts the true vibration information present in both channels. A statistical analysis shows that the probability for deep signal outages is largely decreased. A 60 fold improvement can be shown. The reduction of spikes and noise bursts reduces the noise in the spectral analysis of vibrations too. Over certain frequency bands a reduction of the noise density by a factor above 10 can be shown

  3. Gaussian Pulse-Based Two-Threshold Parallel Scaling Tone Reservation for PAPR Reduction of OFDM Signals

    Directory of Open Access Journals (Sweden)

    Lei Guan

    2011-01-01

    Full Text Available Tone Reservation (TR is a technique proposed to combat the high Peak-to-Average Power Ratio (PAPR problem of Orthogonal Frequency Division Multiplexing (OFDM signals. However conventional TR suffers from high computational cost due to the difficulties in finding an effective cancellation signal in the time domain by using only a few tones in the frequency domain. It also suffers from a high cost of hardware implementation and long handling time delay issues due to the need to conduct multiple iterations to cancel multiple high signal peaks. In this paper, we propose an efficient approach, called two-threshold parallel scaling, for implementing a previously proposed Gaussian pulse-based Tone Reservation algorithm. Compared to conventional approaches, this technique significantly reduces the hardware implementation complexity and cost, while also reducing signal processing time delay by using just two iterations. Experimental results show that the proposed technique can effectively reduce the PAPR of OFDM signals with only a very small number of reserved tones and with limited usage of hardware resources. This technique is suitable for any OFDM-based communication systems, especially for Digital Video Broadcasting (DVB systems employing large IFFT/FFT transforms.

  4. Reduced modeling of signal transduction – a modular approach

    Directory of Open Access Journals (Sweden)

    Ederer Michael

    2007-09-01

    Full Text Available Abstract Background Combinatorial complexity is a challenging problem in detailed and mechanistic mathematical modeling of signal transduction. This subject has been discussed intensively and a lot of progress has been made within the last few years. A software tool (BioNetGen was developed which allows an automatic rule-based set-up of mechanistic model equations. In many cases these models can be reduced by an exact domain-oriented lumping technique. However, the resulting models can still consist of a very large number of differential equations. Results We introduce a new reduction technique, which allows building modularized and highly reduced models. Compared to existing approaches further reduction of signal transduction networks is possible. The method also provides a new modularization criterion, which allows to dissect the model into smaller modules that are called layers and can be modeled independently. Hallmarks of the approach are conservation relations within each layer and connection of layers by signal flows instead of mass flows. The reduced model can be formulated directly without previous generation of detailed model equations. It can be understood and interpreted intuitively, as model variables are macroscopic quantities that are converted by rates following simple kinetics. The proposed technique is applicable without using complex mathematical tools and even without detailed knowledge of the mathematical background. However, we provide a detailed mathematical analysis to show performance and limitations of the method. For physiologically relevant parameter domains the transient as well as the stationary errors caused by the reduction are negligible. Conclusion The new layer based reduced modeling method allows building modularized and strongly reduced models of signal transduction networks. Reduced model equations can be directly formulated and are intuitively interpretable. Additionally, the method provides very good

  5. Bayesian Recovery of Clipped OFDM Signals: A Receiver-based Approach

    KAUST Repository

    Al-Rabah, Abdullatif R.

    2013-05-01

    Recently, orthogonal frequency-division multiplexing (OFDM) has been adopted for high-speed wireless communications due to its robustness against multipath fading. However, one of the main fundamental drawbacks of OFDM systems is the high peak-to-average-power ratio (PAPR). Several techniques have been proposed for PAPR reduction. Most of these techniques require transmitter-based (pre-compensated) processing. On the other hand, receiver-based alternatives would save the power and reduce the transmitter complexity. By keeping this in mind, a possible approach is to limit the amplitude of the OFDM signal to a predetermined threshold and equivalently a sparse clipping signal is added. Then, estimating this clipping signal at the receiver to recover the original signal. In this work, we propose a Bayesian receiver-based low-complexity clipping signal recovery method for PAPR reduction. The method is able to i) effectively reduce the PAPR via simple clipping scheme at the transmitter side, ii) use Bayesian recovery algorithm to reconstruct the clipping signal at the receiver side by measuring part of subcarriers, iii) perform well in the absence of statistical information about the signal (e.g. clipping level) and the noise (e.g. noise variance), and at the same time iv is energy efficient due to its low complexity. Specifically, the proposed recovery technique is implemented in data-aided based. The data-aided method collects clipping information by measuring reliable 
data subcarriers, thus makes full use of spectrum for data transmission without the need for tone reservation. The study is extended further to discuss how to improve the recovery of the clipping signal utilizing some features of practical OFDM systems i.e., the oversampling and the presence of multiple receivers. Simulation results demonstrate the superiority of the proposed technique over other recovery algorithms. The overall objective is to show that the receiver-based Bayesian technique is highly

  6. Performance Investigation of a Handheld 3d Scanner to Define Good Practices for Small Artefact 3d Modeling

    Science.gov (United States)

    Lachat, E.; Landes, T.; Grussenmeyer, P.

    2017-08-01

    Handheld 3D scanners can be used to complete large scale models with the acquisition of occluded areas or small artefacts. This may be of interest for digitization projects in the field of Cultural Heritage, where detailed areas may require a specific treatment. Such sensors present the advantage of being easily portable in the field, and easily usable even without particular knowledge. In this paper, the Freestyle3D handheld scanner launched on the market in 2015 by FARO is investigated. Different experiments are described, covering various topics such as the influence of range or color on the measurements, but also the precision achieved for geometrical primitive digitization. These laboratory experiments are completed by acquisitions performed on engraved and sculpted stone blocks. This practical case study is useful to investigate which acquisition protocol seems to be the more adapted and leads to precise results. The produced point clouds will be compared to photogrammetric surveys for the purpose of their accuracy assessment.

  7. System and Method for Multi-Wavelength Optical Signal Detection

    Science.gov (United States)

    McGlone, Thomas D. (Inventor)

    2017-01-01

    The system and method for multi-wavelength optical signal detection enables the detection of optical signal levels significantly below those processed at the discrete circuit level by the use of mixed-signal processing methods implemented with integrated circuit technologies. The present invention is configured to detect and process small signals, which enables the reduction of the optical power required to stimulate detection networks, and lowers the required laser power to make specific measurements. The present invention provides an adaptation of active pixel networks combined with mixed-signal processing methods to provide an integer representation of the received signal as an output. The present invention also provides multi-wavelength laser detection circuits for use in various systems, such as a differential absorption light detection and ranging system.

  8. Explaining reduction of pedestrian–motor vehicle crashes in Arkhangelsk, Russia, in 2005–2010

    Directory of Open Access Journals (Sweden)

    Alexander V. Kudryavtsev

    2012-09-01

    Full Text Available Objective. To explain a reduction in pedestrian–motor vehicle crashes in Arkhangelsk, Russia, in 2005–2010. Study design. Retrospective ecological study. Methods. For 2005–2010, police data on pedestrian–motor vehicle crashes, traffic violations, and total motor vehicles (MVs were combined with data on changes in national road traffic legislation and municipal road infrastructure. Negative binomial regression was used to investigate trends in monthly rates of pedestrian–motor vehicle crashes per total MVs and estimate changes in these rates per unit changes in the safety measures. Results. During the 6 years, the police registered 2,565 pedestrian–motor vehicle crashes: 1,597 (62% outside crosswalks, 766 (30% on non-signalized crosswalks, and 202 (8% on signalized crosswalks. Crash rates outside crosswalks and on signalized crosswalks decreased on average by 1.1% per month, whereas the crash rate on non-signalized crosswalks remained unchanged. Numbers of signalized and non-signalized crosswalks increased by 14 and 19%, respectively. Also, 10% of non-signalized crosswalks were combined with speed humps, and 4% with light-reflecting vertical signs. Pedestrian penalties for traffic violations increased 4-fold. Driver penalties for ignoring prohibiting signal and failure to give way to pedestrian on non-signalized crosswalk increased 7- and 8-fold, respectively. The rate of total registered drivers’ traffic violations per total MVs decreased on average by 0.3% per month. All studied infrastructure and legislative measures had inverse associations with the rate of crashes outside crosswalks. The rate of crashes on signalized crosswalks showed inverse associations with related monetary penalties. Conclusions. The introduction of infrastructure and legislative measures is the most probable explanation of the reduction of pedestrian–motor vehicle crashes in Arkhangelsk. The overall reduction is due to decreases in rates of crashes

  9. Telomerase activity promotes osteoblast differentiation by modulating IGF-signaling pathway

    DEFF Research Database (Denmark)

    Saeed, Hamid; Qiu, Weimin; Li, Chen

    2015-01-01

    -regulation of several components of insulin-like growth factor (IGF) signaling. Specifically, a significant increase in IGF-induced AKT phosphorylation and alkaline phosphatase (ALP) activity were observed in hMSC-TERT. Enhanced ALP activity was reduced in presence of IGF1 receptor inhibitor: picropodophyllin....... In addition, telomerase deficiency caused significant reduction in IGF signaling proteins in osteoblastic cells cultured from telomerase deficient mice (Terc (-/-)). The low bone mass exhibited by Terc (-/-) mice was associated with significant reduction in serum levels of IGF1 and IGFBP3 as well as reduced...... skeletal mRNA expression of Igf1, Igf2, Igf2r, Igfbp5 and Igfbp6. IGF1-induced osteoblast differentiation was also impaired in Terc (-/-) MSC. In conclusion, our data demonstrate that impaired IGF/AKT signaling contributes to the observed decreased bone mass and bone formation exhibited by telomerase...

  10. MicroCT Bone Densitometry: Context Sensitivity, Beam Hardening Correction and the Effect of Surrounding Media

    Directory of Open Access Journals (Sweden)

    Philip L. Salmon

    2014-12-01

    Full Text Available The context-sensitivity of microCT bone densitometry due to beam hardening artefacts was assessed. Bones and teeth are scanned with varying thickness of surrounding media (water, alcohol, biological tissue and it is important to understand how this affects reconstructed attenuation (“density” of the mineralized tissue. Aluminium tubes and rods with thickness 0.127mm–5mm were scanned both in air or surrounded by up to 2cm of water. Scans were performed with different energy filters and degrees of software beam hardening correction (BHC. Also tested were the effects of signal-to-noise ratio, magnification and truncation. The thickness of an aluminium tube significantly affected its mean reconstructed attenuation. This effect of thickness could be reduced substantially by BHC for scans in air, but not for scans in water. Varying thickness of surrounding water also changed the mean attenuation of an aluminium tube. This artefact could be almost eliminated by an optimal BHC value. The “cupping” artefact of heterogeneous attenuation (elevated at outer surfaces could be corrected if aluminium was scanned in air, but in water BHC was much less effective. Scan truncation, changes to magnification and signal-to-noise ratio also caused artificial changes to measured attenuation. Measurement of bone mineral density by microCT is highly context sensitive. A surrounding layer of liquid or biological tissue reduces the ability of software BHC to remove bone density artefacts. Sample thickness, truncation, magnification and signal to noise ratio also affect reconstructed attenuation. Thus it is important for densitometry that sample and calibration phantom dimensions and mounting materials are standardised.

  11. Contactless Abdominal Fat Reduction With Selective RF™ Evaluated by Magnetic Resonance Imaging (MRI): Case Study.

    Science.gov (United States)

    Downie, Jeanine; Kaspar, Miroslav

    2016-04-01

    Noninvasive body shaping methods seem to be an ascending part of the aesthetics market. As a result, the pressure to develop reliable methods for the collection and presentation of their results has also increased. The most used techniques currently include ultrasound measurements of fat thickness in the treated area, caliper measurements, bioimpedance-based scale measurements or circumferential tape measurements. Although these are the most used techniques, almost all of them have some limitations in reproducibility and/or accuracy. This study shows Magnetic Resonance Imaging (MRI) as the new method for the presentation of results in the body shaping industry. Six subjects were treated by a contactless selective radiofrequency device (BTL Vanquish ME, BTL Industries Inc., Boston, MA). The MRI fat thickness was measured at the baseline and at 4-weeks following the treatment. In addition to MRI images and measurements, digital photographs and anthropometric evaluations such as weight, abdominal circumference, and caliper fat thickness measurements were recorded. Abdominal fat thickness measurements from the MRI were performed from the same slices determined by the same tissue artefacts. The MRI fat thickness difference between the baseline measurement and follow up visit showed an average reduction of 5.36 mm as calculated from the data of 5 subjects. One subject dropped out of study due to non-study related issues. The results were statistically significant based on the Student's T-test evaluation. Magnetic resonance imaging abdominal fat thickness measurements seems to be the best method for the evaluation of fat thickness reduction after non-invasive body shaping treatments. In this study, this method shows average fat thickness reduction of 5.36 mm while the weight of the subjects didn't change significantly. A large spot size measuring 1317 cm(2) (204 square inches) covers the abdomen flank to flank. The average thickness of 5.36 mm of the fat layer reduced

  12. Human airway eosinophils exhibit preferential reduction in STAT signaling capacity and increased CISH expression.

    Science.gov (United States)

    Burnham, Mandy E; Koziol-White, Cynthia J; Esnault, Stephane; Bates, Mary E; Evans, Michael D; Bertics, Paul J; Denlinger, Loren C

    2013-09-15

    Allergic asthma, a chronic respiratory disorder marked by inflammation and recurrent airflow obstruction, is associated with elevated levels of IL-5 family cytokines and elevated numbers of eosinophils (EOS). IL-5 family cytokines elongate peripheral blood EOS (EOS(PB)) viability, recruit EOS(PB) to the airways, and, at higher concentrations, induce degranulation and reactive oxygen species generation. Although airway EOS (EOS(A)) remain signal ready in that GM-CSF treatment induces degranulation, treatment of EOS(A) with IL-5 family cytokines no longer confers a survival advantage. Because the IL-5 family receptors have common signaling capacity, but are uncoupled from EOS(A) survival, whereas other IL-5 family induced endpoints remain functional, we tested the hypothesis that EOS(A) possess a JAK/STAT-specific regulatory mechanism (because JAK/STAT signaling is critical to EOS survival). We found that IL-5 family-induced STAT3 and STAT5 phosphorylation is attenuated in EOS(A) relative to blood EOS from airway allergen-challenged donors. However, IL-5 family-induced ERK1/2 phosphorylation is not altered between EOS(A) and EOS from airway allergen-challenged donors. These observations suggest EOS(A) possess a regulatory mechanism for suppressing STAT signaling distinct from ERK1/2 activation. Furthermore, we found, in EOS(PB), IL-5 family cytokines induce members of the suppressors of cytokine signaling (SOCS) genes, CISH and SOCS1. Additionally, following allergen challenge, EOS(A) express significantly more CISH and SOCS1 mRNA and CISH protein than EOS(PB) counterparts. In EOS(PB), long-term pretreatment with IL-5 family cytokines, to varying degrees, attenuates IL-5 family-induced STAT5 phosphorylation. These data support a model in which IL-5 family cytokines trigger a selective downregulation mechanism in EOS(A) for JAK/STAT pathways.

  13. Acquiring a four-dimensional computed tomography dataset using an external respiratory signal

    International Nuclear Information System (INIS)

    Vedam, S S; Keall, P J; Kini, V R; Mostafavi, H; Shukla, H P; Mohan, R

    2003-01-01

    Four-dimensional (4D) methods strive to achieve highly conformal radiotherapy, particularly for lung and breast tumours, in the presence of respiratory-induced motion of tumours and normal tissues. Four-dimensional radiotherapy accounts for respiratory motion during imaging, planning and radiation delivery, and requires a 4D CT image in which the internal anatomy motion as a function of the respiratory cycle can be quantified. The aims of our research were (a) to develop a method to acquire 4D CT images from a spiral CT scan using an external respiratory signal and (b) to examine the potential utility of 4D CT imaging. A commercially available respiratory motion monitoring system provided an 'external' tracking signal of the patient's breathing. Simultaneous recording of a TTL 'X-Ray ON' signal from the CT scanner indicated the start time of CT image acquisition, thus facilitating time stamping of all subsequent images. An over-sampled spiral CT scan was acquired using a pitch of 0.5 and scanner rotation time of 1.5 s. Each image from such a scan was sorted into an image bin that corresponded with the phase of the respiratory cycle in which the image was acquired. The complete set of such image bins accumulated over a respiratory cycle constitutes a 4D CT dataset. Four-dimensional CT datasets of a mechanical oscillator phantom and a patient undergoing lung radiotherapy were acquired. Motion artefacts were significantly reduced in the images in the 4D CT dataset compared to the three-dimensional (3D) images, for which respiratory motion was not accounted. Accounting for respiratory motion using 4D CT imaging is feasible and yields images with less distortion than 3D images. 4D images also contain respiratory motion information not available in a 3D CT image

  14. Pigment identification on medieval manuscripts, paintings and other artefacts by Raman microscopy: applications to the study of three German manuscripts

    Science.gov (United States)

    Burgio, Lucia; Ciomartan, Dan A.; Clark, Robin J. H.

    1997-03-01

    The identification of the pigments used to illuminate medieval manuscripts, paintings and other artefacts has received a major boost recently through perceptive studies carried out by Raman microscopy. A brief summary of the background of the technique is given. The results of studies on three illuminated German manuscripts are presented. The pigments vermilion HgS, iron oxide Fe 2O 3, azurite 2CuCO 3.Cu(OH) 2, malachite CuCo 3.Cu(OH) 2, lampblack (essentially carbon), white lead 2PbCO 3.Pb(OH) 2, lead tin yellow type I Pb 2SnO 4, and lazurite Na 8[Al 6Si 6O 24]S n (but only in admixture with Pb 2SnO 4, whereby it forms a green pigment), have been identified on these manuscripts on the basis of Raman microscopy and the results discussed.

  15. Modelling the behaviour of the push-pull gel dosimeter

    International Nuclear Information System (INIS)

    Bosi, S.G.; Davies, J.B.; Gorjiara, T.; Baldock, C.

    2010-01-01

    Full text: Recent development of a gel dosimeter based on the radiobleaching pigment, genipin, allows development of a new 3D optically scanned gel dosimeter-the p ush-pull g el. This gel would contain two spectrally complementary pigments, one which darkens with dose and another (e.g. genipin) which bleaches. The two pigments deal separately with the high and low dose ends of the dosimeter's dynamic range. The bleaching pigment would be optimised for high sensitivity and the darkening pigment for low. Employing dual pigments, optimised independently, relaxes the need for compromise between sensitivity at low dose and accuracy at high dose. Such a gel, after exposure, would be read using two successive optical CT scans, at two different wavelengths. The reduction in sensitivity of the darkening pigment (allowed by the use of push-pull) would reduce the occurrence of regions of high optical attenuation which can generate optical CT artefacts. Simulated optical CT reconstructions of the optical density map (Fig. La) scanned at the darkening pigment wavelength of a hypothetical push-pull gel, confirms the reduction in susceptibility to artefacts. Fig. I b shows a profile through the map with no stray light added. The centre of the profile in Fig. I d shows a cupping artefact produced by 10 ppm of stray light. The similarity of Fig. Ic and b show that a 30% sensitivity reduction allowed by push-pull, renders the artefact negligible. This paper presents the results of' these simulations of a push-pull gel scanned using optical CT and also some results of experiments with genipin gel. (author)

  16. Registers of Artefacts of Creation—From the Late Medieval Period to the 19th Century

    Directory of Open Access Journals (Sweden)

    Chris Dent

    2014-06-01

    Full Text Available This paper offers a new perspective on the “development” of the intellectual property regimes in the United Kingdom. The system put in place under the 1875 Trade Marks Act may be seen as the last of a sequence of earlier “technologies” that sought to administer the creative endeavours of (sections of the English population. Prior to the trade mark registration (that included examination there was the registration of designs that did not require examination but was necessary for the protection of the right. In the eighteenth century, patent specifications were lodged with the Crown via a process that was much more involved than that was instituted for designs in the nineteenth century. Before that, books had to be enrolled with the Stationers’ Company before they could be printed. And, in what may be seen as an earlier attempt at the centralised regulation of artefacts of expression, the Rolls of Arms (maintained by the King of Arms was repository of coats of arms for English nobility. An exploration of these different technologies of regulation, in their socio-political context, will offer new insight into the antecedents, and limits, of the registration systems that are now common across the intellectual property world.

  17. Wet-chemical etching of atom probe tips for artefact free analyses of nanoscaled semiconductor structures.

    Science.gov (United States)

    Melkonyan, D; Fleischmann, C; Veloso, A; Franquet, A; Bogdanowicz, J; Morris, R J H; Vandervorst, W

    2018-03-01

    We introduce an innovative specimen preparation method employing the selectivity of a wet-chemical etching step to improve data quality and success rates in the atom probe analysis of contemporary semiconductor devices. Firstly, on the example of an SiGe fin embedded in SiO 2 we demonstrate how the selective removal of SiO 2 from the final APT specimen significantly improves accuracy and reliability of the reconstructed data. With the oxide removal, we eliminate the origin of shape artefacts, i.e. the formation of a non-hemispherical tip shape, that are typically observed in the reconstructed volume of complex systems. Secondly, using the same approach, we increase success rates to ∼90% for the damage-free, 3D site-specific localization of short (250 nm), vertical Si nanowires at the specimen apex. The impact of the abrupt emitter radius change that is introduced by this specimen preparation method is evaluated as being minor using field evaporation simulation and comparison of different reconstruction schemes. The Ge content within the SiGe fin as well as the 3D boron distribution in the Si NW as resolved by atom probe analysis are in good agreement with TEM/EDS and ToF-SIMS analysis, respectively. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Reduction of pattern effects in SOA-based all-optical switches by using cross-gain modulated holding signal

    DEFF Research Database (Denmark)

    Bischoff, Svend; Mørk, Jesper

    2002-01-01

    The effective carrier lifetime of SOAs is typically shortened by an intense Continuous Wave (CW) holding signal. However, the SOA gain is reduced by the holding signal resulting in smaller gain and refractive index changes induced by the data signal. Accordingly, an optimum exists for the CW...... and data signal power. Here, we demonstrate that the modulation bandwidth (amplitude jitter) is significantly improved (reduced) by replacing the CW holding beam with a signal, which is low-pass filtered and inverted with respect to the data signal. Such a holding beam can be generated by XGM WC in an SOA......, and reduces the fluctuations of the total energy injected into the interferometer within a bit-slot. Thus, we demonstrate a technique for reducing pattern effects in SOAs by employing a partially inverted holding beam. The method should be useful for increasing the data rates of all-optical switches....

  19. Compensation of the AKT signaling by ERK signaling in transgenic mice hearts overexpressing TRIM72

    Energy Technology Data Exchange (ETDEWEB)

    Ham, Young-Mi, E-mail: youngmi_ham@hms.harvard.edu [College of Life Science and Biotechnology, Korea University, Seoul (Korea, Republic of); Department of Cell Biology, Harvard Medical School, Boston, MA 02115 (United States); Mahoney, Sarah Jane [Department of Cell Biology, Harvard Medical School, Boston, MA 02115 (United States)

    2013-06-10

    The AKT and ERK signaling pathways are known to be involved in cell hypertrophy, proliferation, survival and differentiation. Although there is evidence for crosstalk between these two signaling pathways in cellulo, there is less evidence for cross talk in vivo. Here, we show that crosstalk between AKT and ERK signaling in the hearts of TRIM72-overexpressing transgenic mice (TRIM72-Tg) with alpha-MHC promoter regulates and maintains their heart size. TRIM72, a heart- and skeletal muscle-specific protein, downregulates AKT-mTOR signaling via IRS-1 degradation and reduces the size of rat cardiomyocytes and the size of postnatal TRIM72-Tg hearts. TRIM72 expression was upregulated by hypertrophic inducers in cardiomyocytes, while IRS-1 was downregulated by IGF-1. TRIM72 specifically regulated IGF-1-dependent AKT-mTOR signaling, resulting in a reduction of the size of cardiomyocytes. Postnatal TRIM72-Tg hearts were smaller than control-treated hearts with inhibition of AKT-mTOR signaling. However, adult TRIM72-Tg hearts were larger than of control despite the suppression of AKT-mTOR signaling. Activation of ERK, PKC-α, and JNK were observed to be elevated in adult TRIM72-Tg, and these signals were mediated by ET-1 via the ET receptors A and B. Altogether, these results suggest that AKT signaling regulates cardiac hypertrophy in physiological conditions, and ERK signaling compensates for the absence of AKT signaling during TRIM72 overexpression, leading to pathological hypertrophy. -- Highlights: • TRIM72 inhibits AKT signaling through ubiquitination of IRS-1 in cardiac cells. • TRIM72 regulates the size of cardiac cells. • TRIM72 regulates size of postnatal TRIM72-overexpressing transgenic mice hearts. • Adult TRIM72-overexpressing transgenic mice hearts showed cardiac dysfunction. • Adult TRIM72 transgenic mice hearts showed higher expression of endothelin receptors.

  20. Compensation of the AKT signaling by ERK signaling in transgenic mice hearts overexpressing TRIM72

    International Nuclear Information System (INIS)

    Ham, Young-Mi; Mahoney, Sarah Jane

    2013-01-01

    The AKT and ERK signaling pathways are known to be involved in cell hypertrophy, proliferation, survival and differentiation. Although there is evidence for crosstalk between these two signaling pathways in cellulo, there is less evidence for cross talk in vivo. Here, we show that crosstalk between AKT and ERK signaling in the hearts of TRIM72-overexpressing transgenic mice (TRIM72-Tg) with alpha-MHC promoter regulates and maintains their heart size. TRIM72, a heart- and skeletal muscle-specific protein, downregulates AKT-mTOR signaling via IRS-1 degradation and reduces the size of rat cardiomyocytes and the size of postnatal TRIM72-Tg hearts. TRIM72 expression was upregulated by hypertrophic inducers in cardiomyocytes, while IRS-1 was downregulated by IGF-1. TRIM72 specifically regulated IGF-1-dependent AKT-mTOR signaling, resulting in a reduction of the size of cardiomyocytes. Postnatal TRIM72-Tg hearts were smaller than control-treated hearts with inhibition of AKT-mTOR signaling. However, adult TRIM72-Tg hearts were larger than of control despite the suppression of AKT-mTOR signaling. Activation of ERK, PKC-α, and JNK were observed to be elevated in adult TRIM72-Tg, and these signals were mediated by ET-1 via the ET receptors A and B. Altogether, these results suggest that AKT signaling regulates cardiac hypertrophy in physiological conditions, and ERK signaling compensates for the absence of AKT signaling during TRIM72 overexpression, leading to pathological hypertrophy. -- Highlights: • TRIM72 inhibits AKT signaling through ubiquitination of IRS-1 in cardiac cells. • TRIM72 regulates the size of cardiac cells. • TRIM72 regulates size of postnatal TRIM72-overexpressing transgenic mice hearts. • Adult TRIM72-overexpressing transgenic mice hearts showed cardiac dysfunction. • Adult TRIM72 transgenic mice hearts showed higher expression of endothelin receptors

  1. Single-Channel Noise Reduction using Unified Joint Diagonalization and Optimal Filtering

    DEFF Research Database (Denmark)

    Nørholm, Sidsel Marie; Benesty, Jacob; Jensen, Jesper Rindom

    2014-01-01

    consider two cases, where, respectively, no distortion and distortion are incurred on the desired signal. The former can be achieved when the covariance matrix of the desired signal is rank deficient, which is the case, for example, for voiced speech. In the latter case, the covariance matrix......In this paper, the important problem of single-channel noise reduction is treated from a new perspective. The problem is posed as a filtering problem based on joint diagonalization of the covariance matrices of the desired and noise signals. More specifically, the eigenvectors from the joint...

  2. Perceptual consequences of different signal changes due to binaural noise reduction: do hearing loss and working memory capacity play a role?

    Science.gov (United States)

    Neher, Tobias; Grimm, Giso; Hohmann, Volker

    2014-01-01

    In a previous study, ) investigated whether pure-tone average (PTA) hearing loss and working memory capacity (WMC) modulate benefit from different binaural noise reduction (NR) settings. Results showed that listeners with smaller WMC preferred strong over moderate NR even at the expense of poorer speech recognition due to greater speech distortion (SD), whereas listeners with larger WMC did not. To enable a better understanding of these findings, the main aims of the present study were (1) to explore the perceptual consequences of changes to the signal mixture, target speech, and background noise caused by binaural NR, and (2) to determine whether response to these changes varies with WMC and PTA. As in the previous study, four age-matched groups of elderly listeners (with N = 10 per group) characterized by either mild or moderate PTAs and either better or worse performance on a visual measure of WMC participated. Five processing conditions were tested, which were based on the previously used (binaural coherence-based) NR scheme designed to attenuate diffuse signal components at mid to high frequencies. The five conditions differed in terms of the type of processing that was applied (no NR, strong NR, or strong NR with restoration of the long-term stimulus spectrum) and in terms of whether the target speech and background noise were processed in the same manner or whether one signal was left unprocessed while the other signal was processed with the gains computed for the signal mixture. Comparison across these conditions allowed assessing the effects of changes in high-frequency audibility (HFA), SD, and noise attenuation and distortion (NAD). Outcome measures included a dual-task paradigm combining speech recognition with a visual reaction time (VRT) task as well as ratings of perceived effort and overall preference. All measurements were carried out using headphone simulations of a frontal target speaker in a busy cafeteria. Relative to no NR, strong NR was found

  3. A computer-aided detection system for rheumatoid arthritis MRI data interpretation and quantification of synovial activity

    International Nuclear Information System (INIS)

    Kubassova, Olga; Boesen, Mikael; Cimmino, Marco A.; Bliddal, Henning

    2010-01-01

    Rational and objective: Disease assessment and follow-up of rheumatoid arthritis (RA) patients require objective evaluation and quantification. Magnetic resonance imaging (MRI) has a large potential to supplement such information for the clinician, however, time spent on data reading and interpretation slow down development in this area. Existing scoring systems of especially synovitis are too rigid and insensitive to measure early treatment response and quantify inflammation. This study tested a novel automated, computer system for analysis of dynamic MRI data acquired from patients with RA, Dynamika-RA, which incorporates efficient data processing and analysis techniques. Materials and methods: 140 MRI scans from hands and wrists of 135 active RA patients and 5 healthy controls were processed using Dynamika-RA and evaluated with RAMRIS. To reduce patient motion artefacts, MRI data were processed using Dynamika-RA, which removed motion in 2D and 3D planes. Then synovial enhancement was visualised and qualified using a novel fully automated voxel-by-voxel analysis based algorithm. This algorithm was used to replace traditional region-of-interest (ROI) and subtraction methods, yielding observer independent quantitative results. Results: Conventional scoring performed by an observer took 30-45 min per dataset. Dynamika-RA reduced motion artefacts, visualised inflammation and quantified disease activity in less than 3 min. Data processing allowed increasing signal to noise ratio by a factor 3. Due to fully automated procedure of data processing, there was no intertest variation in the results. Conclusions: Algorithms incorporated into Dynamika-RA allow for the significant enhancement of data quality through eliminating motion artefacts and reduction of time for evaluation of synovial inflammation.

  4. Model output: fact or artefact?

    Science.gov (United States)

    Melsen, Lieke

    2015-04-01

    As a third-year PhD-student, I relatively recently entered the wonderful world of scientific Hydrology. A science that has many pillars that directly impact society, for example with the prediction of hydrological extremes (both floods and drought), climate change, applications in agriculture, nature conservation, drinking water supply, etcetera. Despite its demonstrable societal relevance, hydrology is often seen as a science between two stools. Like Klemeš (1986) stated: "By their academic background, hydrologists are foresters, geographers, electrical engineers, geologists, system analysts, physicists, mathematicians, botanists, and most often civil engineers." Sometimes it seems that the engineering genes are still present in current hydrological sciences, and this results in pragmatic rather than scientific approaches for some of the current problems and challenges we have in hydrology. Here, I refer to the uncertainty in hydrological modelling that is often neglected. For over thirty years, uncertainty in hydrological models has been extensively discussed and studied. But it is not difficult to find peer-reviewed articles in which it is implicitly assumed that model simulations represent the truth rather than a conceptualization of reality. For instance in trend studies, where data is extrapolated 100 years ahead. Of course one can use different forcing datasets to estimate the uncertainty of the input data, but how to prevent that the output is not a model artefact, caused by the model structure? Or how about impact studies, e.g. of a dam impacting river flow. Measurements are often available for the period after dam construction, so models are used to simulate river flow before dam construction. Both are compared in order to qualify the effect of the dam. But on what basis can we tell that the model tells us the truth? Model validation is common nowadays, but validation only (comparing observations with model output) is not sufficient to assume that a

  5. Sources of Artefacts in Synthetic Aperture Radar Interferometry Data Sets

    Science.gov (United States)

    Becek, K.; Borkowski, A.

    2012-07-01

    In recent years, much attention has been devoted to digital elevation models (DEMs) produced using Synthetic Aperture Radar Interferometry (InSAR). This has been triggered by the relative novelty of the InSAR method and its world-famous product—the Shuttle Radar Topography Mission (SRTM) DEM. However, much less attention, if at all, has been paid to sources of artefacts in SRTM. In this work, we focus not on the missing pixels (null pixels) due to shadows or the layover effect, but rather on outliers that were undetected by the SRTM validation process. The aim of this study is to identify some of the causes of the elevation outliers in SRTM. Such knowledge may be helpful to mitigate similar problems in future InSAR DEMs, notably the ones currently being developed from data acquired by the TanDEM-X mission. We analysed many cross-sections derived from SRTM. These cross-sections were extracted over the elevation test areas, which are available from the Global Elevation Data Testing Facility (GEDTF) whose database contains about 8,500 runways with known vertical profiles. Whenever a significant discrepancy between the known runway profile and the SRTM cross-section was detected, a visual interpretation of the high-resolution satellite image was carried out to identify the objects causing the irregularities. A distance and a bearing from the outlier to the object were recorded. Moreover, we considered the SRTM look direction parameter. A comprehensive analysis of the acquired data allows us to establish that large metallic structures, such as hangars or car parking lots, are causing the outliers. Water areas or plain wet terrains may also cause an InSAR outlier. The look direction and the depression angle of the InSAR system in relation to the suspected objects influence the magnitude of the outliers. We hope that these findings will be helpful in designing the error detection routines of future InSAR or, in fact, any microwave aerial- or space-based survey. The

  6. SOURCES OF ARTEFACTS IN SYNTHETIC APERTURE RADAR INTERFEROMETRY DATA SETS

    Directory of Open Access Journals (Sweden)

    K. Becek

    2012-07-01

    Full Text Available In recent years, much attention has been devoted to digital elevation models (DEMs produced using Synthetic Aperture Radar Interferometry (InSAR. This has been triggered by the relative novelty of the InSAR method and its world-famous product—the Shuttle Radar Topography Mission (SRTM DEM. However, much less attention, if at all, has been paid to sources of artefacts in SRTM. In this work, we focus not on the missing pixels (null pixels due to shadows or the layover effect, but rather on outliers that were undetected by the SRTM validation process. The aim of this study is to identify some of the causes of the elevation outliers in SRTM. Such knowledge may be helpful to mitigate similar problems in future InSAR DEMs, notably the ones currently being developed from data acquired by the TanDEM-X mission. We analysed many cross-sections derived from SRTM. These cross-sections were extracted over the elevation test areas, which are available from the Global Elevation Data Testing Facility (GEDTF whose database contains about 8,500 runways with known vertical profiles. Whenever a significant discrepancy between the known runway profile and the SRTM cross-section was detected, a visual interpretation of the high-resolution satellite image was carried out to identify the objects causing the irregularities. A distance and a bearing from the outlier to the object were recorded. Moreover, we considered the SRTM look direction parameter. A comprehensive analysis of the acquired data allows us to establish that large metallic structures, such as hangars or car parking lots, are causing the outliers. Water areas or plain wet terrains may also cause an InSAR outlier. The look direction and the depression angle of the InSAR system in relation to the suspected objects influence the magnitude of the outliers. We hope that these findings will be helpful in designing the error detection routines of future InSAR or, in fact, any microwave aerial- or space

  7. The Structure of Artefacts of Management Control in the Innovation Process: Does Exist Association with the Strategic Profile?

    Directory of Open Access Journals (Sweden)

    Fábio Frezatti

    2015-01-01

    Full Text Available This study investigates what is the role of strateg ic profiles and management control instruments in organisations’ innovation process. B ased in a survey using structural equation modelling (121 companies, we confirm that analyser , defender e prospector profiles are associated with strategic planning, balanced scorec ard (BSC and rolling forecast. The reactor type is associated with lower use of artefacts. Our results confirm the linkage between incremental innovation and strategic planning and b etween radical innovation and BSC. These findings reflect the alignment between strate gic types, the availability of instruments and intensity of innovation, which is useful inform ation with which to understand organisations and their market activities. This pap er bring information about specific management control instruments existence and the im pact for the intensity of the innovation that is relevant for management and must stimulate organizations to be consistent in the cases that the strategic profile is a clear long term def inition or see the possibility of change when it is not the desired one.

  8. Receiver-based recovery of clipped ofdm signals for papr reduction: A bayesian approach

    KAUST Repository

    Ali, Anum; Al-Rabah, Abdullatif R.; Masood, Mudassir; Al-Naffouri, Tareq Y.

    2014-01-01

    at the receiver for information restoration. In this paper, we acknowledge the sparse nature of the clipping signal and propose a low-complexity Bayesian clipping estimation scheme. The proposed scheme utilizes a priori information about the sparsity rate

  9. Preconditioning with Azadirachta indica ameliorates cardiorenal dysfunction through reduction in oxidative stress and extracellular signal regulated protein kinase signalling

    Directory of Open Access Journals (Sweden)

    Temidayo Olutayo Omóbòwálé

    2016-10-01

    Conclusions: Together, A. indica and vitamin C prevented IRI-induced cardiorenal dysfunction via reduction in oxidative stress, improvement in antioxidant defence system and increase in the ERK1/2 expressions. Therefore, A. indica can be a useful chemopreventive agent in the prevention and treatment of conditions associated with intestinal ischaemia-reperfusion injury.

  10. MOTION ARTIFACT REDUCTION IN FUNCTIONAL NEAR INFRARED SPECTROSCOPY SIGNALS BY AUTOREGRESSIVE MOVING AVERAGE MODELING BASED KALMAN FILTERING

    Directory of Open Access Journals (Sweden)

    MEHDI AMIAN

    2013-10-01

    Full Text Available Functional near infrared spectroscopy (fNIRS is a technique that is used for noninvasive measurement of the oxyhemoglobin (HbO2 and deoxyhemoglobin (HHb concentrations in the brain tissue. Since the ratio of the concentration of these two agents is correlated with the neuronal activity, fNIRS can be used for the monitoring and quantifying the cortical activity. The portability of fNIRS makes it a good candidate for studies involving subject's movement. The fNIRS measurements, however, are sensitive to artifacts generated by subject's head motion. This makes fNIRS signals less effective in such applications. In this paper, the autoregressive moving average (ARMA modeling of the fNIRS signal is proposed for state-space representation of the signal which is then fed to the Kalman filter for estimating the motionless signal from motion corrupted signal. Results are compared to the autoregressive model (AR based approach, which has been done previously, and show that the ARMA models outperform AR models. We attribute it to the richer structure, containing more terms indeed, of ARMA than AR. We show that the signal to noise ratio (SNR is about 2 dB higher for ARMA based method.

  11. Impact of respiratory-correlated CT sorting algorithms on the choice of margin definition for free-breathing lung radiotherapy treatments.

    Science.gov (United States)

    Thengumpallil, Sheeba; Germond, Jean-François; Bourhis, Jean; Bochud, François; Moeckli, Raphaël

    2016-06-01

    To investigate the impact of Toshiba phase- and amplitude-sorting algorithms on the margin strategies for free-breathing lung radiotherapy treatments in the presence of breathing variations. 4D CT of a sphere inside a dynamic thorax phantom was acquired. The 4D CT was reconstructed according to the phase- and amplitude-sorting algorithms. The phantom was moved by reproducing amplitude, frequency, and a mix of amplitude and frequency variations. Artefact analysis was performed for Mid-Ventilation and ITV-based strategies on the images reconstructed by phase- and amplitude-sorting algorithms. The target volume deviation was assessed by comparing the target volume acquired during irregular motion to the volume acquired during regular motion. The amplitude-sorting algorithm shows reduced artefacts for only amplitude variations while the phase-sorting algorithm for only frequency variations. For amplitude and frequency variations, both algorithms perform similarly. Most of the artefacts are blurring and incomplete structures. We found larger artefacts and volume differences for the Mid-Ventilation with respect to the ITV strategy, resulting in a higher relative difference of the surface distortion value which ranges between maximum 14.6% and minimum 4.1%. The amplitude- is superior to the phase-sorting algorithm in the reduction of motion artefacts for amplitude variations while phase-sorting for frequency variations. A proper choice of 4D CT sorting algorithm is important in order to reduce motion artefacts, especially if Mid-Ventilation strategy is used. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Automated Design Tools for Integrated Mixed-Signal Microsystems (NeoCAD)

    National Research Council Canada - National Science Library

    Petre, P; Visher, J; Shringarpure, R; Valley, F; Swaminathan, M

    2005-01-01

    Automated design tools and integrated design flow methodologies were developed that demonstrated more than an order- of-magnitude reduction in cycle time and cost for mixed signal (digital/analoglRF...

  13. Identification of the earliest collagen- and plant-based coatings from Neolithic artefacts (Nahal Hemar cave, Israel).

    Science.gov (United States)

    Solazzo, Caroline; Courel, Blandine; Connan, Jacques; van Dongen, Bart E; Barden, Holly; Penkman, Kirsty; Taylor, Sheila; Demarchi, Beatrice; Adam, Pierre; Schaeffer, Philippe; Nissenbaum, Arie; Bar-Yosef, Ofer; Buckley, Michael

    2016-08-09

    Mortuary practices in human evolution record cognitive, social changes and technological innovations. The Neolithic Revolution in the Levant was a watershed in this domain that has long fascinated the archaeological community. Plaster modelled skulls are well known at Jericho and several other Neolithic sites, and in Nahal Hemar cave (Israel, ca. 8200 -7300 cal. BC) excavations yielded six unique human skulls covered with a black organic coating applied in a net pattern evoking a headdress. This small cave was used as storage for paraphernalia in the semi-arid area of the Judean desert and the dry conditions preserved other artefacts such as baskets coated with a similar dark substance. While previous analysis had revealed the presence of amino acids consistent with a collagen signature, in the present report, specific biomarkers were characterised using combined proteomic and lipid approaches. Basket samples yielded collagen and blood proteins of bovine origin (Bos genus) and a large sequence coverage of a plant protein charybdin (Charybdis genus). The skull residue samples were dominated by benzoate and cinnamate derivatives and triterpenes consistent with a styrax-type resin (Styrax officinalis), thus providing the earliest known evidence of an odoriferous plant resin used in combination with an animal product.

  14. Study of SEM preparation artefacts with correlative microscopy: Cell shrinkage of adherent cells by HMDS-drying.

    Science.gov (United States)

    Katsen-Globa, Alisa; Puetz, Norbert; Gepp, Michael M; Neubauer, Julia C; Zimmermann, Heiko

    2016-11-01

    One of the often reported artefacts during cell preparation to scanning electron microscopy (SEM) is the shrinkage of cellular objects, that mostly occurs at a certain time-dependent stage of cell drying. Various methods of drying for SEM, such as critical point drying, freeze-drying, as well as hexamethyldisilazane (HMDS)-drying, were usually used. The latter becomes popular since it is a low cost and fast method. However, the correlation of drying duration and real shrinkage of objects was not investigated yet. In this paper, cell shrinkage at each stage of preparation for SEM was studied. We introduce a shrinkage coefficient using correlative light microscopy (LM) and SEM of the same human mesenchymal stem cells (hMSCs). The influence of HMDS-drying duration on the cell shrinkage is shown: the longer drying duration, the more shrinkage is observed. Furthermore, it was demonstrated that cell shrinkage is inversely proportional to cultivation time: the longer cultivation time, the more cell spreading area and the less cell shrinkage. Our results can be applicable for an exact SEM quantification of cell size and determination of cell spreading area in engineering of artificial cellular environments using biomaterials. SCANNING 38:625-633, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

  15. Measurement of the Low Frequency Noise of MOSFETs under Large Signal RF Excitation

    NARCIS (Netherlands)

    van der Wel, A.P.; Klumperink, Eric A.M.; Nauta, Bram

    2002-01-01

    A measurement technique [1] is presented that allows measurement of MOSFET low frequency (LF) noise under large signal RF (Radio Frequency) excitation. Measurements indicate that MOSFETS exhibit a reduction in LF noise when they are cycled from inversion to accummulation and that this reduction does

  16. Diffusible signal factor family signals provide a fitness advantage to Xanthomonas campestris pv. campestris in interspecies competition.

    Science.gov (United States)

    Deng, Yinyue; Wu, Jien; Yin, Wenfang; Li, Peng; Zhou, Jianuan; Chen, Shaohua; He, Fei; Cai, Jun; Zhang, Lian-Hui

    2016-05-01

    Diffusible signal factor (DSF) represents a new class of widely conserved quorum sensing signals, which regulates various biological functions through intra- or interspecies signaling. The previous studies identified that there is an antagonistic interaction between Xanthomonas and Bacillus species bacteria in natural ecosystem, but the detailed molecular mechanism of interspecies competition is not clear. This study showed that Xanthomonas campestris pv. campestris (Xcc) interfered with morphological transition and sporulation of Bacillus thuringiensis in mixed cultures, whereas abrogation of the DSF synthase RpfF reduced the interference. DSF inhibited B. thuringiensis cell division and sporulation through modulation of ftsZ, which encodes an important cell division protein in bacterial cells. In addition, RpfF is essential for production of six DSF-family signals in Xcc, which employ the same signaling pathways to regulate biological functions in Xcc and play similar effects on reduction of cell division, sporulation and antibiotic resistance of B. thuringiensis. Furthermore, abrogation of RpfF decreased the competitive capability of Xcc against B. thuringiensis on the surface of Chinese cabbage leaves. Our findings provide new insights into the role of DSF-family signals in interspecies competition and depict molecular mechanisms with which Xcc competes with B. thuringiensis. © 2016 Society for Applied Microbiology and John Wiley & Sons Ltd.

  17. Comparison of PCA and ICA based clutter reduction in GPR systems for anti-personal landmine detection

    DEFF Research Database (Denmark)

    Karlsen, Brian; Larsen, Jan; Sørensen, Helge Bjarup Dissing

    2001-01-01

    This paper presents statistical signal processing approaches for clutter reduction in stepped-frequency ground penetrating radar (SF-GPR) data. In particular, we suggest clutter/signal separation techniques based on principal and independent component analysis (PCA/ICA). The approaches...

  18. Human Airway Eosinophils Exhibit Preferential Reduction in STAT Signaling Capacity and Increased CISH Expression1

    Science.gov (United States)

    Burnham, Mandy E.; Koziol-White, Cynthia J.; Esnault, Stephane; Bates, Mary E.; Evans, Michael D.; Bertics, Paul J.; Denlinger, Loren C.

    2013-01-01

    Allergic asthma, a chronic respiratory disorder marked by inflammation and recurrent airflow obstruction, is associated with elevated levels of Interleukin-5 (IL-5) family cytokines, and elevated numbers of eosinophils (EOS). IL-5 family cytokines elongate peripheral blood EOS (EOSPB) viability, recruit EOSPB to the airways, and at higher concentrations, induce degranulation and reactive oxygen species (ROS) generation. While, EOSA remain signal ready in that GM-CSF treatment induces degranulation, treatment of EOSA with IL-5 family cytokines no longer confers a survival advantage. Since the IL-5 family receptors have common signaling capacity, but are uncoupled from EOSA survival while other IL-5 family induced endpoints remain functional, we tested the hypothesis that EOSA possess a JAK/STAT specific regulatory mechanism (since JAK/STAT signaling is critical to EOS survival). We found that IL-5 family-induced STAT3 and STAT5 phosphorylation is attenuated in EOSA relative to blood EOS from airway allergen-challenged donors (EOSCPB). However, IL-5 family induced ERK1/2 phosphorylation is not altered between EOSA and EOSCPB. These observations suggest EOSA possess a regulatory mechanism for suppressing STAT signaling distinct from ERK1/2 activation. Furthermore, we found, in EOSPB, IL-5 family cytokines induce members of the suppressors of cytokine signaling (SOCS) genes, CISH and SOCS1. Additionally, following allergen challenge, EOSA express significantly more CISH and SOCS1 mRNA and CISH protein than EOSPB counterparts. In EOSPB, long-term pretreatment with IL-5 family cytokines, to varying degrees, attenuates IL-5 family induced STAT5 phosphorylation. These data support a model wherein IL-5 family cytokines trigger a selective down-regulation mechanism in EOSA for JAK/STAT pathways. PMID:23956426

  19. Vismodegib, an antagonist of hedgehog signaling, directly alters taste molecular signaling in taste buds

    International Nuclear Information System (INIS)

    Yang, Hyekyung; Cong, Wei-na; Yoon, Jeong Seon; Egan, Josephine M

    2015-01-01

    Vismodegib, a highly selective inhibitor of hedgehog (Hh) pathway, is an approved treatment for basal-cell carcinoma. Patients on treatment with vismodegib often report profound alterations in taste sensation. The cellular mechanisms underlying the alterations have not been studied. Sonic Hh (Shh) signaling is required for cell growth and differentiation. In taste buds, Shh is exclusively expressed in type IV taste cells, which are undifferentiated basal cells and the precursors of the three types of taste sensing cells. Thus, we investigated if vismodegib has an inhibitory effect on taste cell turnover because of its known effects on Hh signaling. We gavaged C57BL/6J male mice daily with either vehicle or 30 mg/kg vismodegib for 15 weeks. The gustatory behavior and immunohistochemical profile of taste cells were examined. Vismodegib-treated mice showed decreased growth rate and behavioral responsivity to sweet and bitter stimuli, compared to vehicle-treated mice. We found that vismodegib-treated mice had significant reductions in taste bud size and numbers of taste cells per taste bud. Additionally, vismodegib treatment resulted in decreased numbers of Ki67- and Shh-expressing cells in taste buds. The numbers of phospholipase Cβ2- and α-gustducin-expressing cells, which contain biochemical machinery for sweet and bitter sensing, were reduced in vismodegib-treated mice. Furthermore, vismodegib treatment resulted in reduction in numbers of T1R3, glucagon-like peptide-1, and glucagon-expressing cells, which are known to modulate sweet taste sensitivity. These results suggest that inhibition of Shh signaling by vismodegib treatment directly results in alteration of taste due to local effects in taste buds

  20. Technology in neurology

    African Journals Online (AJOL)

    Repro

    Promising developments in clinical neuro- physiology over the last 10 ... and cerebral or brain wave study (elec- ... or directly muscles) activity from inside the ... Left: raw data showing severe artefact. Right: same signal after being filtered.